Loading...
HomeMy WebLinkAboutB12-0097NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES Mofu�i Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: 812 -0097 Project #: PRJ12 -0047 Job Address: 22 W MEADOW DR VAIL Applied.....: 04/12/2012 Location......: VILLA CORTINA UNIT 360 Issued...: 05/08/2012 Parcel No....: 210107108025 OWNER VILLA APEX LLC 04/12/2012 AROCHI MARROQUIN & LINDNER S.C. INSURGENTES SUR 1605 -PISO 20 MEXICO CITY MX CONTRACTOR HEID CUSTOM BUILDERS, INC RIK HEID PO BOX 4909 EDWARDS CO 81632 License: C000003204 APPLICANT VILLA APEX LLC 04/12/2012 AROCHI MARROQUIN & LINDNER S.C. INSURGENTES SUR 1605 -PISO 20 MEXICO CITY MX 04/12/2012 Phone: 970 - 390 -2674 Description: INTERIOR REMODEL, ADD EXTERIOR WINDOW, MOVE EXISTING BAY WINDOW TO NEW LOCATION AND ADD 105 SQUARE FEET OF LIVING SPACE. Occupancy: R -3 Type Construction: VB FEE SUMMARY Valuation: $370,000.00 Building Permit ------ - - - - -> $2,505.75 Bldg Plan Check ----- - - - - -> $1,628.74 Use Tax Fee------------------ - - - - -> $7,200.00 Electrical Permit --- - - - - -> $115.00 Elec Plan Check ------ - - - - -> $74.75 Restuarant Plan Review--- - - - - -> $0.00 Mechanical Permit - - - - -> $500.00 Mech Plan Check ---- - - - - -> $125.00 Additional Fees--------------- - - - - -> $2,526.83 Plumbing Permit --- - - - - -> $285.00 Plmb Plan Check ---- - - - - -> $71.25 Recreation Fee--------------- - - - - -> $105.00 Investigation------------------ - - - - -> $0.00 Will Call ------------------------------ > $20 00 TOTAL PERMIT FEES--------- - - - - -> $15,157.32 Payments ------------------------------- > $15,157.32 BALANCE DUE ------------------------ > $0.00 DECLARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM. combination permit-012811 CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B12 -0097 Owner: VILLA APEX LLC CORTINA UNIT 360 Cond: CON0012543 upgrade smoke detection to tie into the building panel. Stubout for fire sprinkler system. Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 combination permit-012811 Address: 22 W MEADOW DR VAIL Location: VILLA TOWN OF VAILL7 Permit #: B12 -0097 Owner: VILLA APEX LLC CORTINA UNIT 360 REQUIRED INSPECTIONS AND STATUSES Address: 22 W MEADOW DR VAIL Location: VILLA Item: 00120 ELEC -Rough Item: 00200 MECH -Rough Item: 00220 PLMB- Rough /D.W.V, Item: 00240 PLMB -Gas Piping Item: 00230 PLMB- Rough/Water Item: 00030 BLDG - Framing Item: 00050 BLDG - Insulation Item: 00060 BLDG - Sheetrock Nail Item: 00390 MECH -Final Item: 00190 ELEC -Final Item: 00290 PLMB -Final Item: 00542 PLAN -FINAL Item: 00090 BLDG -Final combination permit-012811 TOWN OF VAIL, COLORADO Statement Statement Number: R120000460 Amount: $12,240.2605/08 /201203:47 PM Payment Method: Check Init: LC Notation: #1900 /RIK HEID CUSTOM BUILDERS ----------------------------------------------------------------------------- Permit No: B12 -0097 Type: COMBINATION BLDG PERMIT Parcel No: 2101 -071- 0802 -5 Site Address: 22 W MEADOW DR VAIL Location: VILLA CORTINA UNIT 360 Total Fees: $15,157.32 This Payment: $12,240.26 Total ALL Pmts: $15,157.32 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts 11000003113300, CHPO HOUSING FEE IN LIEU 2,526.83 BP 00100003111100 BUILDING PERMIT FEES 2,408.43 RF 11100003112700 RECREATION FEES 105.00 UT 11000003106000 USE TAX 40 7,200.00 TOWN OF VAIL, COLORADOCopy Reprinted on 05-08-2012 at 16:01:03 05/08/2012 Statement xxxxxxxxxxxxxxx x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x xxxxxxxx Statement Number: 8120000258 Amount: $2,917.06 04/12/201209:04 AM Payment Method:Credit Crd Init: DR Notation: MASTERCARD ----------------------------------------------------------------------------- Permit No: B12-0097 Type: COMBINATION BLDG PERMIT Parcel No: 2101-071-0802-5 Site Address: 22 W MEADOW DR VAIL Location: VILLA CORTINA UNIT 360 Total Fees: $15,157.32 This Payment: $2,917.06 Total ALL Pmts: $15,157.32 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- BP 00100003111100 ------------------------------ ------ BUILDING PERMIT FEES - - - - -- 97.32 EP 00100003111100 ELECTRICAL PERMIT FEES 115.00 MP 00100003111100 MECHANICAL PERMIT FEES 500.00 PF 00100003112300 PLAN CHECK FEES 1f899.74 PP 00100003111100 PLUMBING PERMIT FEES 285.00 WC 00100003112800 WILL CALL INSPECTION FEE 20.00 BUILDING PERMIT APPLICATION Separate permits are required for electrical, plumbing, mechanical, fireplace, etc. Project Street Address: Office Use: w,.r,�, 5T m Fr,AD�iO� . 0 3 (o Project #: (Number) (Street) j )�J .� /' /L(Suite #) DRB #: ���� Q(�c3 Building /Complex Name:vf —`—� `0�z`'�%rl Building Permit #: Co ntractor Information: Lot #: Block # Subdivision. Co Company: pp(� P�5�n1 6ultj�Ls, //LC_ . Company Address: f_O 126L )! U cl Detailed Scope and Location of Work: City: EO w4k OS State: CO zip: 9'' G 3 Z /C ( A1 -,) , �f %3i� [ i�S A�DPffCkl b9,0/1Q Contact Name: �K IT�(%�. ADD Ut IspaL✓, Contact Phone: 7 VU ,2 7 7 000 (S. E -Mail (use additional sheet if necessary) KckUrf����s�o�,gu��o��s_ ���, Town of Vail Contractor �Registration No.: X Contractor Signature (required) Work Class: New ( ) Addition ( ) Remodel ( ', /) Repair ( ) Other ( ) Work Type Interior ( V ) Exterior ( ) Both ( ) Property Information Type of Building: Parcel #: lUi v7l — 09.1 U ZS Single - Family ( ) Duplex ( ) Multi - Family (}j (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or Commercial( ) Other( ) visit www.eaglecounty.us /patie) Tenant Name: n p Does a Fire Alarm Exist? Yes No( ) Owner Name: Ul LL� f 'y— L L C- Monitored Alarm? Yes (x) No( ) Does a Sprinkler System Exist? Yes ( ) No (K) Valuations (Labor & Materials) Building: Plumbing: Electrical: Mechanical: (including fireplace) Total: 0 $ 3 -20'(')00 `' 40`2917.0(.0 gDk3 °%f`l 0(o`7`l q RI K S . NEID D+EBoeHH W t rrfnAN Jo c, # & Type of Existing Fireplaces: Gas Appliances Gas Log / Wood /Pellet Wood Burning # & Type of Proposed Fireplaces: Gas Appliances ! Gas Log _� Wood /Pellet Wood Burning_ Date Received APR 11 201 TOWN OF VAIL O1- Jan -]0 e C 0 S 1 %nvirnnmcnl,tl IIi`,ixinr H,:,,inroIimi Im;. Date: 4 -19 -2012 Asbestos Abatement 11?00401f To: Rik Heid Regarding: 22 Meadow Dr. unit #360 Vail, CO Mr. Heid, On 04 -16 -2012, ECOS Environmental & Disaster Restoration Inc. (ECOS) abated 30 sq.ft. of (ACM). The ACM (asbestos containing materials), identified from our inspection, was located in the downstairs bathroom ceiling. All abatement procedures complied with standards per Colorado Department of Public Health & Environment (CDPHE) regulations. Unit #360 at the Villa Corinas in Vail, CO was found to have (ACM) that was described as White Joint Compound and White Joint Compound w/ White Paint. Please feel free to contact Josh Johnson with queries or to make arrangements for any necessary abatement activities. Sincerely, Josh Johnson Project Manager ECOS Environmental 2i� -anon PROJECT: Villa Contina PROJECT #: MOUNTING: Recessed TYPE: SO D N OD ORE UAL PANEL ENGINEER: VOLTAGE: MAINS: AIC: 120/208V, 1 P, 3W 200A MLO 10K PHASE PHASE DESCRIPTION A B BKR P ICIR CIR P BKR A B DESCRIPTION Rece t 720 20 1 11 2 1 20 720 Bedroom Rece t Living Room Ltq, Rece t 1260 20 1 3 4 1 20 600 Bedroom Lts Hall Bath Rm 870 1 20 1 5 6 1 20 1600 Bedroom Lts Rece t 1900 20 1 7 8 1 20 900 Heat Mat SPACE 0 1 20 1 9 10 1 20 900 Heat Mat Kitchen Rece t 720 20 1 11 12 1 20 750 MB Bath Lts Kitchen Rece t 720 20 11 13 14 1 20 360 MB Bath Rece t Entry Ltq, Rece t 870 20 11 115 16 11 20 750 Jacuzzi Washer 700 20 11 rl 7 18 11 20 1750 Jacuzzi Landary Lts 200 20 11 19 20 11 20 1 750 Jacuzzi Landary 1600 30 12 21 22 12 13250 Range Kitchen Lts 12200 20 1 23 24 13250 Kitchen Rece t 720 1 20 1 25 26 2 3750 Dryer Kitchen Lts 1750 20 1 27 28 3750 Kitchen Rece t 720 1 20 1 129 30 1 20 720 Bedroom Closet Rece t Refq 11200 20 1 131 32 1 20 800 MB Lt Micro 1000 1 20 1 33 134 12 14500 Steamer Disposal 1750 20 1 35 36 1 4500 Dishwasher 600 20 1 37 38 10 SPACE Exhaust Hood 500 20 1 39 40 0 SPACE Not Used 0 41 42 0 Not Used LOAD CALCULATION SUMMARY CALCULATED POWER FACTOR 0.99 CONNECTED LOAD LIGHTING 5500 RECEPTACLES 8100 MECHANICAL 1800 KITCHEN 33200 TOTAL 48600 The Contractor shall provide arc fault and or GFIC circuit breakers as outline in the NEC Or as directed by the Authority having Jurisdiction. CONNECTED AMPS DEMAND LOAD DEMAND AMPS 28 5500 28 39 8100 39 10 2025 11 160 21580 104 237 37205 182 12-12-2012 Inspection Request Reporting Page 1-- 4:24 pm Vail, CO - City Of Requested Inspect Date: Thursday, December 13, 2012 Site Address: VILLA CORTI AD UNIT 360 A/P/D Information Status: ISSUED Const Type Type: COMBO Sub Type: AMF Activity B12-0097 Occupancy: Use: R-3 Insp Area: Owner VILLA APEX LLC Contractor: HEID CUSTOM BUILDERS, INC Phone: 970-390-2674 Description: INTERIOR 105 SQUARE ADD EXTERIOR TERIOOR WINDOW, MOVE EXISTING BAY WINDOW TO NEW LOCATION AND ADD Requested Inspection(s), Item 542 PLAN-FINAL Requested Time: 08:30 AM Phone: Requester Comments 390-2674 Entered By: MHAEBERLE K Assigned To BGIBSON Time Exp: Action G, R Pf''°,► a Item 90 BLDG-Final Requested Time: 02:30 PM Phone: Requestor Comments 390-2674 Entered By: MHAEBERLE K Assigned To JMONDRAGON Action Time Exp: Item 190 ELEC-Final Requested Time: 04:00 PM Phone: Requestor Comments 390-2674 Entered By: MHAEBERLE K Assigned To JMONDRAGON Action Time Exp: Item 290 PLMB-Final Requested Time: 03:30 PM Requestor Phone: Comments 390-2674 Entered By: MHAEBERLE K Assigned To JMONDRAGON Action Time Exp: , 2—P ` Qcb o . (p Inspection History Item: 120 ELEC-Rough **Approved** 09/12/12 Inspector: mdenney Action: AP APPROVED Comment: Item: 200 MECH-Rough **Approved" 09/13/12 Inspector: mdenney Action: AP APPROVED Comment: fireplace and hydro mcs. tem: 220 PL 2/1h I Approved" 09/12/12 Inspector: mdenney Action: AP APPROVED Comment: Item: 240 PLMB-Gas Piping Approved" Item: 230 PL 09/12/12 R hpector: mdenney Action: AP APPROVED Comment: REPT131 Run Id: 15035 , , . , 4,11,-- 001 02-06-2013 Inspection Request Reporti Page 2� ec P 4:14 pm Vail, CO p- City Of Requested Inspect Date: Thursday February 07 2013 Site Address: 22 W MEADOW DR VAIL VILLA CORTINA UNIT 360 A/P/D Information Activity B12-0097 Type: COMBO Sub Type: AMF Status: ISSUED Const Type Occupancy: Use: R-3 Insp Area: Owner VILLA APEX LLC Contractor: HEID CUSTOM BUILDERS, INC Phone: 970-390-2674 Description: INTERIOR REMODEL ADD EXTERIOR WINDOW,MOVE EXISTING BAY WINDOW TO NEW LOCATION AND ADD 105 SOUAFE FEET OF LIVING SPACE. Requested Inspection(s) Item. 90 BLDG-Final Requested Time: 02:00 PM Requestor Phone: Comments FOLLOW UP Assigned To JMONDRAG \ Entered By: JMONDRAGON K Comme Action Time Exp: Inspection History Item: 120 ELEC-Rough **Approved** 09/12/12 Inspector: mdenney Action: AP APPROVED Comment: Item: 200 MECH-Rough h **Approved** 09/13/1 Inspector: mdenney Action: AP APPROVED Comment: fireplace and hydronics. Item: 220 PLMB-Rough/D.W.V. Approved** 09/12/12 Inspector: mdenney Action: AP APPROVED Comment: Item: 230 PLMB-Rough/Water **Approved** 09/12/12 Inspector: mdenney Action: AP APPROVED Comment: Item: 30 BLDG-Framing **Approved** 09/13/12 Inspector: mdenney Action: AP APPROVED Comment: Item: 50 BLDG-Insulation **Approved** 09/19/12 Inspector: mdenney Action: AP APPROVED Comment: Item: 60 BLDG-Sheetrock Nail **Approved** 09/27/12 Inspector: sgremmer Action: AP APPROVED Comment: Item: 390 MECH-Final **Approved** 12/14/12 Inspector: sgremmer Action: AP APPROVED Comment: Item: 190 ELEC-Final **Approved** 12/14/12 Inspector: sgremmer Action: AP APPROVED Comment: Item: 290 PLMB-Final **Approved** 12/14/12 Inspector: sgremmer Action: AP APPROVED Comment: Item: 542 PLAN-FINAL **Approved** 12/13/12 Inspector: bgibson Action: AP APPROVED Comment: Item: 90 BLDG-Final **Approved** 12/14/12 Inspector: sgremmer Action: AP APPROVED I Comment: REPT131 Run Id: 15061