Loading...
HomeMy WebLinkAboutB12-0099 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES �..� _ ,. �r�^i;���:� � Town of Vail,Community Development, 75 South Frontage Road,Vail, Colorado 81657 p.970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B12-0099 Project #: PRJ12-0140 Job Address: 4501 SPRUCE WY VAIL Applied.....: 04/12/2012 Location......: SPRUCE WAY TOWNHOMES UNIT B Issued. . . : 04/16/2012 Parcel No....: 210112331004 OWNER TIMOTHY A.GAGNER REVOCABLE 04/12/2012 4501 SPRUCE WY#B VAI L CO 81657 APPLICANT WESTERN FIREPLACE SUPPLY 04/12/2012 Phone:970-827-9623 910 NOTTINGHAM ROAD AVON CO 81620 License:C000003171 CONTRACTOR WESTERN FIREPLACE SUPPLY 04/12/2012 Phone:970-827-9623 910 NOTTINGHAM ROAD AVON CO 81620 License:C000003171 Description: REPLACE EXISTING GAS FIREPLACE WITH NEW DIRECT VENT GAS F/P 8 VENTING UTILIZE EXISTING GAS 8 ELECTRICAL LINES, FIREPLACE MODEL EXCAPE 42 DV Occupancy: Type Construction: Valuation: $4,469.00 ,,�.....,,.>..>,...<............................................................. FEE SUMMARY ,.,,,,.,,....,,,.,...,,,......,.<....,.,..,,....,....,,.,,...,,.......,........ Building Permit-----------> $111.25 Bldg Plan Check----------> $72.31 Use Tax Fee----------------------> $0.00 Electrical Permit---------> $0.00 Elec Plan Check-----------> $0.00 Restuarant Plan Review--------> $0.00 Mechanical Permit------> $100.00 Mech Plan Check---------> $25.00 Additional Fees--------------------> ($183.56) Plumbing Permit--------> $0.00 Plmb Plan Check---------> $0.00 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $5.00 TOTAL PERMIT FEES-------------> $130.00 Payments-------------------------------> $130.00 BALANCE DUE------------------------> $0.00 .....................,,,._.,.,,.��.,,.....,._�...�.�.,,,,,.,,.,,,,.,,,,>...,,.............>........,.....,....>..,,,,..�.......,>...,�„�.<_...._.._...,.>,.....,�,�........,.,,�»,,..,,.......,,,, DECLARATIONS i hereby acknowledge that I have read this application,filled out in full the information required,completed an accurate plot plan,and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws,and to build this structure according to the town's zoning and subdivision codes,design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUES FOR IN I L BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM-4:0 `� /G -Z e of Owner or Contractor D te -5 0� i'�l�-+�-�.S Print Name combination permit_012811 ..................�,,.....,..,.,......,,.,....,.,.,.,.....,.�.,.,,.,..,...,,.,.....,......,...,.......,.,,.,,,.,...,,�,...,....,,,,,,.,,.,..,..�....,.,,....,......,..�..,,,.,.,;,... CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit#: B12-0099 Address: 4501 SPRUCE WY VAIL Owner: TIMOTHY A. GAGNER REVOCABLE TRUST-NANCY L. GAGNER REVOCABLE TRUST Location: SPRUCE WAYTOWNHOMES UNIT B ,,,,,,,,,,,,,,,,,,,,,,,,,,�....,�.,.,.,.>�..,,,,.�.,,,,�.,>��,��.,..,.,.�..,.<..,,....�.....,...,..,.,.,..,,....,..,..,...,..,..,..,,.,,..,,,,�.,.....,,..,..,.,...,,,,,,,...,,,.,.,, combination permit_012811 � � ������ � ��***#*#***�**���*��*�������*>�*�*�*�**�*��**#**#*******��*�*��*��*��*�������*�****,�*****�*****�***��*��****�**���*����*x�«**����*����������������� REQUIRED tNSPECTIONS AND STATUSES Permit#: B12-0099 Address: 4501 SPRUCE WY VAIL Owner: TIMOTHY A. GAGNER REVOCABLE TRUST- NANCY L. GAGNER REVOCABLE TRUST Location: SPRUCE WAY TOWNHOMES UNIT B ���***�****�*�*************#**************�*****�**��***�**�*******�****�***�************�*�*�*****�*�*�**���*�*�*��**�***�******�*�*��**����**���*** Item: 00200 MECH-Rough Item: 00390 MECH-Final Item: 00090 BLDG-Final combination permit_012811 Inspection Items for B12-0099 14:28 01/31/2014 Sec Item Id Description A r Re Items Action Inheritable * 200 MECH-Rou h Yes R 1 AP No 390 MECH-Final Yes R 1 AP No * 90 BLDG-Final Yes R 1 AP No Total Rows:3 Page 1 ################**####****##*#*#####*##*##########**#####**##&*#####*#*####*###*#*###*###### TOWN OF VAIL, COLORADO Statement ***�*****�*****�****�*****�*�******�*******���*************��******************************* Statement Number: R120000274 Amount: $107.55 04/16/201209=54 AM Payment Method: Check Init: SAB Notation: 3019 - WESTERN FIREPLACE SUPPLY Permit No: B12-0099 Type: COMBINATION BLDG PERMIT Parcel No: 2101-123-3100-4 Site Address: 4501 SPRUCE WY VAIL Location: SPRUCE WAY TOWNHOMES UNIT B Total Fees: $130.00 This Payment: $107_55 Total ALL Pmts: $130.00 Balance: $0. 00 *********************************************+********************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ MP 00100003111100 MECHANICAL PERMIT FEES 100.00 PF 00100003112300 PLAN CHECK FEES 2 .55 WC 00100003112800 WILL CALL INSPECTION FEE 5.00 ----------------------------------------------------------------------------- ********************�****�************ **sr******************r****�********** *s*��**�******** TOWN OF VAIL, COLORADO Statement ******�*�*******�**********�***�****** *******�*****��**r.**���***�*****�*��* ********r**�**** Statement Number:R120000262 Amount: $22.4504/12/201204:45 PM Payment Method: Check Init: LC Notation: #3017 / WESTERN FIREPLACE SUPPLY ------------------------------ ------------------------------ ----------------- Permit No:B12-0099 Type. COMBINATION BLDG PERMIT Parcel No:2101-123-3100-4 Site Address: 4501 SPRUCE WY VAIL Location: SPRUCE WAY TOWNHOMES UNIT B Total Fees: $130.00 This Payment: $22.45Tota1 ALL Pmts: $22.45 Balance: $107.55 **s********�***************�********** *****�*************�****************** *t****s******+�* ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ---- -------------------------- PF 00100003112300 PLAN CHECK FEES 22.45 ------------------------------ ------------------------------ ----------------- 0 ,.: 4 � � �^�"'.+i.:�'�� .x��> ������,4 a2s '� ."i.t4,�a. f „,w`.,+,�a i-2f�� e'+����5;�" ��.C:�. ��':'� - . . �r �s.��`4yr y�i� ''Y *s1 �3 ,+F ('"Y 'F ' ! . a'A` 4t.. � � � rrr� :;tl�� �� M . � _ . a, -. .- �.• :��� �. �d � � � �: � �� �-�-� � , �� s�.� � .7'3jS�, wth Fr�tag�. ; �.�; " s . �. �.• �,� � �. . •�#* I +i� �. �" 'r '", ��. . "��"1� � ��''�' '' _ ,•y��� �'�.� �y � . -w: ; - � � � .��� . � $'': d y.'� �f�s �� ,,�,. � � �� • ��'��,. y �� . k � A �M .'': �Y.�s}.. ��. ���Vy�. �� Fk �y ,�*� f s l,.' �,rr BUILDING PERMIT APPLICATION (Separate applications are required for alarm &sprinkier) . ..._._.._._.__ ._ ,___. _...._.. ..._ _ .... __ ...._ _....__.._ �Project Street Address: Project#: Z �' ���� c� f 5 P�� ��� _� (Numberl. (Street) � (Sulte#) DRB#: Building/Complex Name: Building Permit#: 1�`� � l. 1 F ...,..�.,� ..m,..,...._ ,......._. . ............. .._.: . ....,.. . . ..�.:,. .__.. .� Lot#: Block# Subdivision: Contractor Informatbn Business Name:kiF�S'f�t� �1�.pL�-�- SclQ PLY ;Work Class: New� Addition O Alteration O Business Address: Po 80�C �Z�Z 'Type of Buitding: T.^�.TT������.�_.�.......___.._.._____.._.._..,.._....__.....�.--- City l�JD�-f State: C� Zip: 8 I�0 20 t Single-Family( ) Duplex� Multi-Family( ) Contact Name: ��� ;Commercial( ) Other( ) i `Contact Phone: 8 Z7= �l C�,23 f work Type: y Interior� Exterior( ) Both( )�� , i. Contact E-MaiL• So�-@W.�T�I�'FI�LflC�.Gct��"`�.....m".""...�.�:,"_°'...�.,_'"m_."`..."_`°.""".""�,..'.�...°'..�.`.""`Valua�on of ! M Work Included Plans Included Work Cor�tractor Registration tJumber: c�2 3�, ` �Electricy�l ( )Yes ( )No ( )Yes ( )No ;X (Mecha�ical �'j�1'es ( )No �QYes ( )No sentative S(gnature(Required) �Plumbirjg ( )Yes ( )No ( )Yes ( )No ; ;___..._._m.._..._.___T.�__...,�.._._ _.__.___..�_..._ __..... __.._.__ ...__.._.__�.__�., ',Project infom�atb� �- 1 ��Building ( )Yes ( )No ( )Yes ( )No ;Owner Name: 71 Nj �,��E (2 1 WS( ����: s Parcel#: ��( — 123—� ( ` �� 'Value qf all work being pertormed: $ i(Fw Pvcsl#,coMact Eapk County Asssssors Otfice et(970-32&8640 or vlsit -��°alue ba�ed on IBC Section 109.3&IRC SecUon 108.3) �"""'"•°°91°��!�'•�) ;Electric;al Square Footage : Detailed Scope�and Location of Work:�Ql.l�C�- �X 16�(ll�(.C�; 4f�S `�)P-�P N ' J ` 1..A� i�l I�F-f 1•4�� � �Q-�-T V�r�T �f�S -F�� � tl��lTr�G, c.�Ti�IZ� ;�1C �ST�n�� G�4-C � �L�-G�'2( C '' L.�n��S � ±��...�e�,�-� r�o��� a` �5�,�.-P� �-Z e� '` `(use additional sheet if n�essary) For OfHce Use Onl • 22 � Date Received:�..�.^....�..T.^._..�....�.._...._ _�__..._....__ Fee Paid: p Received From. � l� �- ��e ' � (� ���� Cash Check# Q l � U CC: Visa/MC Last 4 CC# exp date: � � 0 �� AUtl1 # � / vti ��� TOWN 01= V�►�1� 1 Para obtener un ejemplar en Espar�ol de este Pour demander un exemplaire en frangais de ce Manuel Manual del propietario,visite www.heatnglo.com. du propri�taire,visitez www.heatnglo.com. HEAT GLO.. Owner's Manual Instailation and Operation No one builds a better fire O Model: GAS-FIRED Escape-42DV Esca � � M � � : C u�. US :r D � '"� � APR l 0 2012 ;� LISTED . NOTICE � DO NOT DISCARD THIS MANUAL � � I I • Important operating • Read,understand and follow • Leave this manual with I ;,�, and maintenance these instructions for safe pa�ty responsible for use '�''�� instructions included. installation and operation. and operation. A WARNING: If the information in these A WARNING instructions is not followed exactly, a fire HOT SURFACES! or explosion may result causing property 1` Glass and othersurfaces are hot dunng damage, personal injury, or death. operation AND cool down. Hot glass will cause burns. • DO NOT store or use gasoline or other flam- • DO NOT touch glass until it is cooled mable vapors and liquids in the vicinity of this • NEVER alfow children to touch glass or any other appliance. • Keep chifdren away • CAREFULLY SUPERVISE children in same room as • What to do if you smell gas fireplace. - DO NOT try to light any appliance. • Alert chifdren and adults to hazards of high temperatures. High temperatures may ignite clothing orotherflammable - DO NOT touch any electrical switch. DO materials. NOT use any phone in your building. • Keep clothing, furniture, draperies and other flammable - Immediately call your gas supplier from a materials away. neighbor'S phOCt@. FOIIOW th@ 98S SU(Jpll- This appliance has been supplied with an integral barrier er'S If1St�UCtIOf1S. to prevent dir�ect contact with the fxed glass paneL DD - {f you cannot reach your gas supplier, call NOT operate the appliance with the barrier removed. th@ fll'@ depal"tf11@�t. Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. • Installation and service must be perFormed by a qualified installer, service agency, or the g8S SUpp�l2f. In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter. See Table of Contents for location of additional Commonwealth This appliance may be installed as an OEM installation in of Massachusetts requirements. manufactured home(USA only)or mobile home and must be installed in accordance with the manufacturer's instructions and the manufactured home construction and safety standard, Installation and service of this appliance should be Title 24 CFR, Part 3280 or Standard for Insta�lation in Mobile o:.;� perforrned by qualified personnel. Hearth & Home Homes, CAN/CSA Z240MH,in Canada. � L Technologies suggests NFI certified or fadory trained This appliance is only for use with the type(s)of gas indicated �,s " professionals, or technicians supervised by an NFI on the rafing plate. cert'rfied professional. Heat&Glo • Escape-42DV • 2052-900 Rev.X • 3/11 1 1 Listing and Code Approvals A. Appliance Certification C. BTU Specifcations MODEL: ESCAPE-42DV MOd@IS �nP�m M'niP�m �e LABORATORY: Underwriters Laboratories,lnc.(UL) (u.s.orCanada) en�m eium �wNS� TYPE: Direct Vent Gas Appliance Heater �a2o�o�o Fn 52,000 35,000 26 STANDARD:ANSI Z21.88-2002•CSA2.33-M2002•UL307B Escape-42DV(NG) CANADA 46,8�0 31,5�� 27 (2000-4500 F'� us 50,000 33,000 45 This product is listed to ANSI standards for"Vented Gas �a2000Fr� Appliance Heaters"and applicable sections of"Gas Burn- Escape-42DV(LP) CANADA ing Heating Appliances for Manufactured Homes and �2��F� 45,000 29,700 46 Recreational Vehicles°, and "Gas Fired Appliances for Use at High Altitudes". D. High Altitude Installations NOT/CE: This installation must conform with local codes. NOT/CE:If the heating value of the gas has been reduced, In the absence of local codes you must comply wifh the these ndes do not apply. Check with your local gas utility National Fuel Gas Code, ANS/ Z223.1-/atest edition in or authorities having jurisdiction. the U.S.A. and the CAN/CGA 8149 Insfallafion Codes in �en installing above 2000 feet elevation: Canada. • In the USA: Reduce input rate 4% for each 1000 feet NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE. above 2000 feet. This appliance is tested and approved as either supplemen- • In CANADA: Reduce input rate 10% for elevations tal room heat or as a decorative appliance. It should not be between 2000 feet and 4500 feet. Above 4500 feet, factored as primary heat in residential heating calculations. Consult 1oC21 gas utility. Check with your local gas utility to determine proper B. Glass Specifications orifice size. This appliance is equipped with 5 mm ceramic glass. Re- place glass only with 5 mm ceramic glass. Please contact E. Non-Combustible Materials Specification your dealer for replacement glass. Material which will not ignite and bum.Such materials are those consisting entirely of steel,iron,brick,tile,concrete, slate, glass or plasters, or any combination thereof. Materials that are reported as passing ASTM E 136, Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 °C and UL763 shall be considered non-combustible materials. F. Combustible Materials Specification Materials made of or surfaced with wood, compressed pa- per, plant fibers, plastics, or other material that can ignite and burn, whether flame proofed or not, or plastered or unplastered shall be considered combustible materials. G. Electrical Codes NOTICE: This appliance must be electrically wired and grounded in accordance with/oca/codes or,in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Cade CSA C22.1. • A 110-120 VAC circuit for this product must be protected with ground-fault arcuit-i�e�rupter protection,in compliance with the applicable electrical codes,when it is installed in locations such as in bathrooms or near sinks. Heat&Glo • Escape�2DV • 2052-900 Rev.X • 3/11 7