Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B12-0035 Electrical plans approved
RECEI V V ED 03/30/12 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/12/12 TYPEDESCRIPTIONMANUFACTURERCATALOG NUMBERMOUNTINGNOLAMPVOLTSDIMENSIONSREMARKS ADJUSTABLE CMH MR16 CYLINDER SIGN 20W CMH MR16XX IN CAT. # = FINISH PER B1LIGHT, 30° CUTOFF SHIELD, RECESSED LSI INDUSTRIESALV SL 16CMH A S3DR XX AGCUSTOM13 000K, 80+ CRI1206.36" LARCHITECT LENS, WET RATED, REMOTE BALLAST 40° FLOOD 6" COMPACT FLUORSCENT OPEN D1DOWNLIGHT, CLEAR ALZAK REFLECTORPRESCOLITETBX-TO4SRECESSED132W CFL12013" L X 7-1/2" W X 7-1/2" H 4000K, 80+ CRI 4' LINEAR FLUORESCENT STRIP PROVIDE TUBE SLEEVES TO F1LIGHT, 2-LAMP WITH TUBE SLEEVESCOLUMBIACS4-232-EUSURFACE24' 32W T812048" L X 4-7/16" W X 1-13/16" HPROTECT LAMPS 4000K, 80+ CRI 4' LINEAR FLUORSCENT WALL MOUNT PROVIDE BATTERY BACKUP F2FIXTURE, 2-LAMP, ACRYLIC LENS,COLUMBIAW4-232-EU-ELSURFACE24' 32W T812048" L X 4-7/8" H X 4" DBALLAST EMERGENCY BATTERY BACKUP 4000K, 80+ CRI LED EXIT SIGN WITH BATTERY BACKUP,XITWHITE W GREEN LETTERINGDUAL LITELXUGWESURFACEN/AGREEN LED'S12013" W X 9" H X 1-7/8" D LUMINAIRE SCHEDULE NOTE: ALTERNATE EQUIVALENT LIGHTING PACKAGES ACCEPTED WITH ENGINEER'S REVIEW OF SUBMITTAL.TAG DESCRIPTION LOAD VOLTAGE PHASE WIRE SIZE (CU)CONNECTION CIRCUIT BREAKER REMARKS THARMAL EF-1EXHAUST FAN #157 W1201(2 #12, 1 #12G) 1/2"COVERLOAD20A1P SWITCH THARMAL CUH-1CABINET UNIT HEATER #11/15 HP1201(2 #12, 1 #12G) 1/2"COVERLOAD20A1P SWITCH THARMAL SP-1SUMP PUMP #1.3 HP1201(2 #12, 1 #12G) 1/2"COVERLOAD20A1P SWITCH NOTE: VERIFY ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN.MECHANICAL SCHEDULE Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/12/12 PROJECT: LIONSQUARE LODGE SOUTH INFILLENGINEER:DCF PROJECT #: 11056 VOLTAGE:120/208V, 3P IN, 1P OUT MOUNTING: SURFACE MAINS:600A MLO TYPE: GE AIC:EXISTING PHASE PHASE DESCRIPTION A BBKR PCIRCIR P BKR A BDESCRIPTION PANEL 4508770 10021221008770 PANEL PH II CONDO " 877034 8770"PANEL 5508965 10025621008770 PANEL PH II CONDO " 896578 8770"PANEL 65012260 100291021008770 PANEL PH II CONDO " 122601112 8770"PANEL 75011300 1002131421008770 PANEL PH II CONDO " 113001516 8770"PANEL PH II CONDO8770 1002171821008770 PANEL PH II CONDO " 87701920 8770"PANEL PH II CONDO8770 1002212221008770 PANEL PH II CONDO " 87702324 8770"PANEL 1568770 ???225 " 877027 LOAD CALCULATION SUMMARY CALCULATED POWER FACTOR:1.00 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS APPLIANCES18020501351537 LIGHTING & RECEPT.10748029839568110 MECHANICAL9503972.53 KITCHEN OVEN & DRYER11400031643280120 TOTAL24045066797336270 METERBANK PH II PROJECT: LIONSQUARE LODGE SOUTH INFILLENGINEER:DCF PROJECT #: 11056 VOLTAGE:120/208V, 1P, 3W MOUNTING: RECESSED MAINS:100A MLO TYPE: SQUARE D QO (NEW)AIC:EXISTING PHASE PHASE DESCRIPTION A BBKR PCIRCIR P BKR A BDESCRIPTION ENTRY BEDROOM #11280 20112120750 INSTA HOT RANGE 400050234120 425POWDER ROOM "4000 561201080 LIVING ROOM OUTLETS KITCHEN LIGHTS 60020178120 1500DINING ROOM KITCHEN OUTLET #11500 201910120600 LIVING ROOM LIGHTS BEDROOM #2 12802011112120 525BATH #1 SPACE0 13140 SPACE SPACE 01516 0SPACE SPACE0 17180 SPACE SPACE 01920 0SPACE SPACE0 21220 SPACE SPACE 02324 0SPACE LOAD CALCULATION SUMMARYNOTE: PROVIDE ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION-TYPE CIRCUIT BREAKERS FOR BRANCH CIRCUITS SUPPLYING ALL 120V POWER OUTLETS EXCEPT IN KITCHENS, BATHROOMS, AND GARAGES.CALCULATED POWER FACTOR:ALL EXISTING CIRCUITS THIS UNIT SHALL BE RE-FED WITH NEW BREAKERS IN NEW PANEL.1.00 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS APPLIANCES75047504 LIGHTING & RECEPT.870042499524 MECHANICAL901101.251 KITCHEN OVEN & DRYER800038640031 TOTAL17540841224659 PANEL UNIT 450 PROJECT: LIONSQUARE LODGE SOUTH INFILLENGINEER:DCF PROJECT #: 11056 VOLTAGE:120/208V, 1P, 3W MOUNTING: RECESSED MAINS:100A MLO TYPE: SQUARE D QO (NEW)AIC:EXISTING PHASE PHASE DESCRIPTION A BBKR PCIRCIR P BKR A BDESCRIPTION EAST BEDROOM REC (5)900 20112120230 EAST BATHROOM KITCHEN REC 150020134120 1400LR & WEST BR LIGHTS BATH & KITCHEN LIGHTS1200 201561201500 NORTH KITCHEN REC REFRIGERATOR 100020178250 4000RANGE DISPOSAL1000 2019104000 "MICROWAVE 12002011112 0SPACE SPACE0 13140 SPACE SPACE 01516 0SPACE SPACE0 17180 SPACE SPACE 01920 0SPACE SPACE0 21220 SPACE SPACE 02324 0SPACE LOAD CALCULATION SUMMARYNOTE: PROVIDE ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION-TYPE CIRCUIT BREAKERS FOR BRANCH CIRCUITS SUPPLYING ALL 120V POWER OUTLETS EXCEPT IN KITCHENS, BATHROOMS, AND GARAGES.CALCULATED POWER FACTOR:ALL EXISTING CIRCUITS THIS UNIT SHALL BE RE-FED WITH NEW BREAKERS IN NEW PANEL.1.00 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS APPLIANCES320015320015 LIGHTING & RECEPT.668032428821 MECHANICAL50062.50 KITCHEN OVEN & DRYER800038640031 TOTAL17930861395167 PANEL UNIT 550 PROJECT: LIONSQUARE LODGE SOUTH INFILLENGINEER:DCF PROJECT #: 11056 VOLTAGE:120/208V, 1P, 3W MOUNTING: RECESSED MAINS:100A MLO TYPE: SQUARE D QO (NEW)AIC:EXISTING PHASE PHASE DESCRIPTION A BBKR PCIRCIR P BKR A BDESCRIPTION BATH & LV REC1440 20112120360 RIGHT BATH REC COOKTOP 325040234240 3250OVEN "3250 563250 "ENTRY & LEFT BEDROOM 144020178120 900BATH LIGHTING RIGHT BEDROOM1080 201910120600 KITCHEN LIGHTING MICROWAVE 12002011112120 1500KITCHEN REC REFRIGERATOR1000 20113141201000 DISHWASHER SPACE 01516120 1000DISPOSAL SPACE0 17180 SPACE SPACE 01920 0SPACE SPACE0 21220 SPACE SPACE 02324 0SPACE LOAD CALCULATION SUMMARYNOTE: PROVIDE ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION-TYPE CIRCUIT BREAKERS FOR BRANCH CIRCUITS SUPPLYING ALL 120V POWER OUTLETS EXCEPT IN KITCHENS, BATHROOMS, AND GARAGES.CALCULATED POWER FACTOR:ALL EXISTING CIRCUITS THIS UNIT SHALL BE RE-FED WITH NEW BREAKERS IN NEW PANEL.1.00 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS APPLIANCES420020420020 LIGHTING & RECEPT.732035451222 MECHANICAL0000 KITCHEN OVEN & DRYER1300063845041 TOTAL245201181716283 PANEL UNIT 650 PROJECT: LIONSQUARE LODGE SOUTH INFILLENGINEER:DCF PROJECT #: 11056 VOLTAGE:120/208V, 1P, 3W MOUNTING: RECESSED MAINS:100A MLO TYPE: SQUARE D QO (NEW)AIC:EXISTING PHASE PHASE DESCRIPTION A BBKR PCIRCIR P BKR A BDESCRIPTION EAST BEDROOM REC (5)900 201121201500 PENINSULA GFI OVEN 250030234120 1500N. KITCHEN GFI "2500 561201500 W. KITCHEN GFI RECEPTACLES 020178250 4000COOKTOP SPACE0 9104000 "SPACE 01112120 1200MICROWAVE SPACE0 13141201920 DISPOSAL/DW SPACE 01516120 1080W. BEDROOM SPACE0 17180 SPACE SPACE 01920 0SPACE SPACE0 21220 SPACE SPACE 02324 0SPACE LOAD CALCULATION SUMMARYNOTE: PROVIDE ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION-TYPE CIRCUIT BREAKERS FOR BRANCH CIRCUITS SUPPLYING ALL 120V POWER OUTLETS EXCEPT IN KITCHENS, BATHROOMS, AND GARAGES.CALCULATED POWER FACTOR:ALL EXISTING CIRCUITS THIS UNIT SHALL BE RE-FED WITH NEW BREAKERS IN NEW PANEL.1.00 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS APPLIANCES312015234011 LIGHTING & RECEPT.648031421820 MECHANICAL0000 KITCHEN OVEN & DRYER1300063845041 TOTAL226001091500872 PANEL UNIT 750 PROJECT: LIONSQUARE LODGE SOUTH INFILLENGINEER:DCF PROJECT #: 11056 VOLTAGE:120/208V, 3P IN, 1P OUT MOUNTING: SURFACE MAINS:800A MLO TYPE: GE AIC:EXISTING PHASE PHASE DESCRIPTION A BBKR PCIRCIR P BKR A BDESCRIPTION PANEL 5547945 702122708570 PH III CONDO " 794534 8570"PH III CONDO8570 70256270 8570 PH III CONDO " 857078 8570"PH III CONDO8570 702910270 8570 PH III CONDO " 85701112 8570"PH III CONDO8570 7021314270 8570 PH III CONDO " 85701516 8570"PH III CONDO8570 7021718270 8570 PH III CONDO " 85701920 8570"PH III CONDO8570 7022122270 8570 PH III CONDO " 85702324 8570"PH III CONDO8570 7022526270 8570 PH III CONDO " 85702728 8570"PH III CONDO8570 7022930270 8570 PH III CONDO " 85703132 8570"PH III CONDO8570 7023334270 8570 PH III CONDO " 85703536 8570"PH III CONDO8570 7023738270 8570 PH III CONDO " 85703940 8570" LOAD CALCULATION SUMMARYNOTE: PART 2 LOADS INCLUDED BELOW.CALCULATED POWER FACTOR:1.00 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS APPLIANCES21250591593844 LIGHTING & RECEPT.23094064082779229 MECHANICAL248082491.258 KITCHEN OVEN & DRYER22400062053760149 TOTAL4786701327154968430 METERBANK PH III (PART 1 OF 2)PROJECT: LIONSQUARE LODGE SOUTH INFILLENGINEER:DCF PROJECT #: 11056 VOLTAGE:120/208V, 3P IN, 1P OUT MOUNTING: SURFACE MAINS:800A MLO TYPE: GE AIC:EXISTING PHASE PHASE DESCRIPTION A BBKR PCIRCIR P BKR A BDESCRIPTION PH III CONDO 8570 702122708570 PH III CONDO " 857034 8570"PH III CONDO 8570 702562708570 PH III CONDO " 857078 8570"PH III CONDO 8570 7029102708570 PH III CONDO " 85701112 8570"PH III CONDO 8570 70213142708570 PH III CONDO " 85701516 8570"SPACE0 17180 SPACE SPACE 01920 0SPACE SPACE0 21220 SPACE SPACE 02324 0SPACE SPACE0 25260 SPACE SPACE 02728 0SPACE SPACE0 29300 SPACE SPACE 03132 0SPACE SPACE0 33340 SPACE SPACE 03536 0SPACE SPACE0 37380 SPACE SPACE 03940 0SPACE LOAD CALCULATION SUMMARYNOTE: LOADS BELOW INCLUDED IN PART 1 LOAD CALCS.CALCULATED POWER FACTOR:1.00 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS APPLIANCES600017450012 LIGHTING & RECEPT.664001842519070 MECHANICAL7202742.52 KITCHEN OVEN & DRYER640001772304064 TOTAL13712038053473148 METERBANK PH III (PART 2 OF 2)PROJECT: LIONSQUARE LODGE SOUTH INFILLENGINEER:DCF PROJECT #: 11056 VOLTAGE:120/208V, 3P, 4W MOUNTING: SURFACE MAINS:200A MLO TYPE: GE AIC:EXISTING PHASE PHASE DESCRIPTION A B CBKR PCIRCIR P BKR A B CDESCRIPTION FA PANEL AT FRONT DESK200 201121201200 SHOP MICROWAVE UNKNOWN 500 20134120 500 UNKNOWN TV CABLE REC 36020156120 600EAST SO BLDG STAIR LTS TELEPHONE ROOM REC &360 20178120500 UNKNOWN BOILER ROOM LIGHTS 0 910120 660 ELECTRICAL METER ROOM NEW SAUNA 16634021112120 500UNKNOWN "1663 1314120360 CHNG RM SINK REC 6TH FLR BALCONY LIGHTS 400 2011516120 360 WMNS CHG RM TABLE REC SAUNA HEATER 16634021718120 360WMNS CHG RM TABLE REC "1663 1920120500 UNKNOWN REST ROOM 2ND 580 2012122220 300 3RD FLR LOBBY LIGHTS (KB)2ND FLR LTS/REC AT RRS 7602012324 300KB SALAD BAR DESK/LBBY/CNCRGE LTS600 2012526120800 KB SALAD BAR FRONT DESK REC 1080 2012728120 600 4TH FLR HALL LTS PH II 5TH FLR BALCONY LIGHTS 4002012930120 600FRONT DESK SYKES MACH.1ST FLR ICE MACHINE980 2023132120180 REC FOR ICE MACHINE " 980 3334120 34 (N) ELEV HOLD OPENS CHNG RM LTS - WOMENS 40020135363125 10969(N) PANEL #9 CHNG RM LTS - MENS400 201373810969 "CHNG RM HALL LIGHTS 400 2013940 10969 "2ND FLR LOBBY LIGHTS 6002014142120 500UNKNOWN LOAD CALCULATION SUMMARY CALCULATED POWER FACTOR:0.95 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS LIGHTING13650381365038 RECEPTACLES15154421257735 MECHANICAL18397601888762 KITCHEN11410321141032 TOTAL5861117156524166 PANEL #3 PROJECT: LIONSQUARE LODGE SOUTH INFILLENGINEER:DCF PROJECT #: 11056 VOLTAGE:120/208V, 3P, 4W MOUNTING: RECESSED MAINS:125A MLO TYPE: SQUARE D AIC:10K PHASE PHASE DESCRIPTION A B CBKR PCIRCIR P BKR A B CDESCRIPTION HEAT TAPE 4TH UPR DECK1632 20112120450 ELEVATOR LOBBY HEATER HEAT TAPE 1632 20134120 720 DESK REC HEAT TAPE 163220156120 540LOBBY REC HEAT TAPE1632 20178120540 LOBBY REC HEAT TAPE 1632 201910120 1080 OFFICE REC/COMPUTER 0 2002011112120 600LIGHTING ATTIC BOILER200 20113141201080 DESK COMPUTERS ATTIC BOILER 200 2011516120 1275 LOBBY HEAT PANELS CHRISTMAS TREE 3 6002011718120 600ENTRY/BRZWAY LIGHTS CHRISTMAS TREE600 2011920120600 ROCK WALL LIGHTS CHRISTMAS TREE 3 600 2012122120 720 PLANTER REC CHRISTMAS TREE 4 6002012324120 600PARKING LOT LIGHT CHRISTMAS TREE600 20125261201080 OFFICE REC NEW CHRISTMAS TREE 3 600 2012728120 600 TREE 2 HEAT TAPE UPPER ROOF 16323012930120 600TREE 1 FRONT ENTRY VESTIBULE783 2023132220783 A/C CONDENSER HEATER 783 3334 783 "UNKNOWN 7832023536120 500UNKNOWN "783 3738230980 UNKNOWN UNKNOWN 500 2013940 980 "(N) CUH-1 1752014142 0SPACE LOAD CALCULATION SUMMARY CALCULATED POWER FACTOR:0.91 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS LIGHTING720020720020 RECEPTACLES736020736020 MECHANICAL18347601883761 KITCHEN0000 TOTAL3290710033397102 PANEL #9 PROJECT: LIONSQUARE LODGE SOUTH INFILLENGINEER:DCF PROJECT #: 11056 VOLTAGE:120/208V, 3P, 4W MOUNTING: SURFACE MAINS:200A MLO TYPE: GE AIC:EXISTING PHASE PHASE DESCRIPTION A B CBKR PCIRCIR P BKR A B CDESCRIPTION 1ST FLR HALL REC WEST540 20112120600 1ST FLR HALL LTS 1ST FLR HALL REC EAST 540 20134120 600 1ST FLR HALL LTS UNKNOWN 50020156120 500UNKNOWN 2ND FLR HALL REC540 20178120600 2ND FLR LIGHTS 2ND FLR HALL LTS 600 201910120 540 2ND FLR HALL REC OUTSIDE OFFICE STAIR LTS 6002011112120 9603RD FL HALL LTS E/SKI REC 4TH FLR HALL LTS WEST600 2011314120600 3RD FLR HALL LTS WEST 3TH FLR HALL LTS EAST 600 2011516120 540 3RD FLR HALL REC 4TH FLR HALL REC 5402011718120 5403RD FLR HALL REC 4TH FLR HALL REC540 2011920220100 4TH/5TH FLR HALL HEAT UNKNOWN 500 2012122 100 XFMR FOR ZONE VALVE 5TH FLR HALL LTS WEST 6002012324120 1006TH FLR HALL HEAT XFMR 5TH FLR HALL LTS EAST600 2012526120100 7TH FLR HALL HEAT XFMR CLMBN RM ELEV WALL REC 540 2012728120 540 5TH FLR HALL REC UNKNOWN 5002012930120 6005TH FL HALL REC/6&7 LTS (N) N STAIR/MAIDS LTG/EF-1704 2013132120600 COPY ROOM R. WIRE (N) PANEL ELEV 713 3023334120 1080 RESERVATIONS SERVERS " 71335362100 4905PANEL MAID?(N) NEW ELEVATOR3069 50337384905 "SHUNT TRIP 3069 3940 0 SPACE " 30694142 0SPACE LOAD CALCULATION SUMMARYNOTE: ALL LOADS SHOWN HERE FOR REFERENCE TO TOTAL PANEL LOAD. EXISTING LOADS INCLUDED ON HMDC CALCS UNDER MAX DEMAND.CALCULATED POWER FACTOR:0.95 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS LIGHTING923226923226 RECEPTACLES15240421262035 MECHANICAL122134014514.547 KITCHEN150049753 TOTAL3818511237342111 PANEL #6 PROJECT: LIONSQUARE LODGE SOUTH INFILLENGINEER:DCF PROJECT #: 11056 VOLTAGE:120/208V, 1P, 3W MOUNTING: SURFACE MAINS:30A MLO TYPE: GE AIC:EXISTING PHASE PHASE DESCRIPTION A BBKR PCIRCIR P BKR A BDESCRIPTION ELEV PIT LIGHTING/REC212 20112120430 CAR LIGHTS/REC/FAN SUMP PUMP 60020134 0SPACE SPACE0 560 SPACE LOAD CALCULATION SUMMARY CALCULATED POWER FACTOR:0.92 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS LIGHTING23212321 RECEPTACLES36023602 MECHANICAL65048005 KITCHEN0000 TOTAL1242713927 PANEL ELEV PROJECT: LIONSQUARE LODGE SOUTH INFILLENGINEER:DCF PROJECT #: 11056 VOLTAGE:120/208V, 3P, 4W MOUNTING: SURFACE MAINS:1,600A MLO TYPE: GE AV-LINE SWITCHBOARD AIC:EXISTING PHASE PHASE DESCRIPTION A B CBKR PCIRCIR P BKR A B CDESCRIPTION METERBANKS239707 60031232000 SWITCH #13 " 239707 34 0 "" 23970756 0"RESTAURANT MAIN0 600378380021937 HOUSE MDC " 0 910 21937 "" 01112 21937"LOAD CALCULATION SUMMARYNOTE: LOADS FROM NEW MDC SECTION INCLUDED BELOW. CALCULATED POWER FACTOR:1.00 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS COMMERCIAL LOADS255050711304479849 RESI. APPLIANCES392701092945382 RESI. LIGHTING/REC338420937120397334 RESI. MECHANICAL343011343011 RESI. KITCHEN33800093675600209 TOTAL97417027055333591485 MAIN DISTRIBUTION CENTER (MDC)PROJECT: LIONSQUARE LODGE SOUTH INFILLENGINEER:DCF PROJECT #: 11056 VOLTAGE:120/208V, 3P, 4W MOUNTING: SURFACE MAINS:800A MLO TYPE: GE AV-LINE SWITCHBOARD AIC:EXISTING PHASE PHASE DESCRIPTION A B CBKR PCIRCIR P BKR A B CDESCRIPTION PANEL #50 6031232000 PANEL #4 EXISTING LOADS INCL. 0 34 0 EXISTING LOADS INCL.IN MAX DEMAND 056 0IN MAX DEMAND PANEL POOL ROOM (P)0 100378320058 PANEL #3 EXISTING LOADS INCL. 0 910 58 EXISTING LOADS INCL.IN MAX DEMAND 01112 58IN MAX DEMAND PANEL #63778 2003131432000 PANEL #7 EXISTING LOADS INCL. 3778 1516 0 EXISTING LOADS INCL.IN MAX DEMAND 37781718 0IN MAX DEMAND 20320018100 PANEL HEAT TRACE 22 18100 PROVIDE NEW FUSES &24 18100FEEDER LOAD CALCULATION SUMMARY NOTE: ONLY NEW LOADS ARE SHOWN ABOVE. ALL EXISTING LOADS ARE INCLUDED IN MAX DEMAND BELOW CALCULATED POWER FACTOR:0.97 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS MAX DEMAND FEB 2011107000296133750370 LIGHTING83228322 RECEPTACLES54015401 MECHANICAL10138331244041 KITCHEN5430015054300150 TOTAL172810484201862565 HOUSE MAIN DISTRIBUTION CENTER (HMDC)PROJECT: LIONSQUARE LODGE SOUTH INFILLENGINEER:DCF PROJECT #: 11056 VOLTAGE:120/208V, 3P, 4W MOUNTING: SURFACE MAINS:200A MLO TYPE: BYLIN HECS HEAT TAPE CONTROL PANELAIC:10K PHASE PHASE DESCRIPTION A B CBKR PCIRCIR P BKR A B CDESCRIPTION S. ROOF SNOWMELT - 229'1374 302122301650 N. ROOF SNOWMELT - 275'30 mA GFI 1374 34 1650 30 mA GFI S. ROOF SNOWMELT - 250' 150030256230 1674N. ROOF SNOWMELT - 279'30 mA GFI1500 781674 30 mA GFI S. ROOF SNOWMELT - 208' 1248 302910230 1680 N. ROOF SNOWMELT - 280'30 mA GFI 12481112 168030 mA GFI S. ROOF SNOWMELT - 178'1068 3021314230624 N. ROOF SNOWMELT - 104'30 mA GFI 1068 1516 624 30 mA GFI S. ROOF SNOWMELT - 275' 16503021718230 1134N. ROOF SNOWMELT - 189'30 mA GFI1650 19201134 30 mA GFI S. ROOF SNOWMELT - 207' 1242 3022122230 1524 N. ROOF SNOWMELT - 254'30 mA GFI 12422324 152430 mA GFI S. ROOF SNOWMELT - 237'1422 30225262301278 N. ROOF SNOWMELT - 213'30 mA GFI 1422 2728 1278 30 mA GFI S. ROOF SNOWMELT - 265' 15903022930230 1806N. ROOF SNOWMELT - 301'30 mA GFI1590 31321806 30 mA GFI S. ROOF SNOWMELT - 193' 1158 3023334230 1188 4TH LVL N HEAT TRACE - 198'30 mA GFI 11583536 118830 mA GFI S. ROOF SNOWMELT - 208'1248 30237382301092 4TH LVL N HEAT TRACE - 182'30 mA GFI 1248 3940 1092 30 mA GFI SPACE 04142 0SPACE LOAD CALCULATION SUMMARY CALCULATED POWER FACTOR:1.00 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS LIGHTING0000 RECEPTACLES0000 MECHANICAL0000 KITCHEN5430015054300150 TOTAL5430015054300150 PANEL HEAT TRACE PROJECT: LIONSQUARE LODGE SOUTH INFILLENGINEER:DCF PROJECT #: 11056 VOLTAGE:120/208V, 1P, 3W MOUNTING: RECESSED MAINS:70A MLO TYPE: SQUARE D QO (NEW)AIC:EXISTING PHASE PHASE DESCRIPTION A BBKR PCIRCIR P BKR A BDESCRIPTION KITCHEN1500 201121201080 LOFT DISPOSAL 100020134120 1500KITCHEN KITCHEN1500 201561201080 BEDROOM RANGE 400050278120 230BATHROOM "4000 9100 SPACE SPACE 01112 0SPACE SPACE0 13140 SPACE SPACE 01516 0SPACE SPACE0 17180 SPACE SPACE 01920 0SPACE SPACE0 21220 SPACE SPACE 02324 0SPACE LOAD CALCULATION SUMMARYNOTE: PROVIDE ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION-TYPE CIRCUIT BREAKERS FOR BRANCH CIRCUITS SUPPLYING ALL 120V POWER OUTLETS EXCEPT IN KITCHENS, BATHROOMS, AND GARAGES.CALCULATED POWER FACTOR:ALL EXISTING CIRCUITS THIS UNIT SHALL BE RE-FED WITH NEW BREAKERS IN NEW PANEL.1.00 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS APPLIANCES1000510005 LIGHTING & RECEPT.684033434421 MECHANICAL50062.50 KITCHEN OVEN & DRYER800038640031 TOTAL15890761180757 PANEL UNIT 554 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/12/12 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/12/12 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/12/12 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/12/12 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/12/12 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/12/12 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/12/12 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/12/12 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/12/12 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/12/12