Loading...
HomeMy WebLinkAboutB12-0040 - COMCHECK approvedProject Title: Vail Public Library Report date: 04/05/12 Data filename: C:\Brennan\Work\10030 Vail Public Library\Calculations\VPL Interior Lighting Comcheck 3-30-12.cckPage 1 of 6 COM check Software Version 3.9.0 Interior Lighting Compliance Certificate 2009 IECC Section 1: Project Information Project Type: Alteration Project Title : Vail Public Library Construction Site:Owner/Agent:Designer/Contractor:292 West Meadow Drive Vail, CO 81657 Town of Vail Vail, CO Brennan Schumacher David Nelson & Associates, LLC P.O. Box 270254 Littelton, CO 80127 303-730-2456 brennan@dnalighting.com Section 2: Interior Lighting and Power Calculation A Area Category B Floor Area (ft2)C Allowed Watts / ft2 D Allowed Watts (B x C)Main Library (Library)27751.33608 Periodicals (Library)4501.3585 Stacks (Library)20121.32616 Period and News (Library)3421.3445 Book Sales (Retail)951.5143 Storage 4 (Library): Exempt Child Storage (Library): Exempt Book Sales Storage (Library): Exempt Storage 3 (Library): Exempt Sitting (Library)9551.31242 Teen's Library (Library)22751.32958 Classrooms (Library)10671.31387 Multipurpose Room (Library)13701.31781 Circulation (Library)17201.32236 Upper Office (Library)13501.31755 Lower Level (Library)20661.32686 Total Allowed Watts =21439 Area Category Exemption Qualifications Total Wattage Total Pre-Alt.# Fixtures Activity Area Pre-Alt.Post-Alt.Fixtures Repl./Added Storage 4 ( Library 35 sq.ft.): Exemption: Replacement of bulbs and ballasts only.9060------Child Storage ( Library 52 sq.ft.): Exemption: Replacement of bulbs and ballasts only.9060------Book Sales Storage ( Library 90 sq.ft.): Exemption: Replacement of bulbs and ballasts only.9060------Storage 3 ( Library 107 sq.ft.): Exemption: Replacement of bulbs and ballasts only.9060------Section 3: Interior Lighting Fixture Schedule A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/Fixture C # of Fixtures D Fixture Watt.E (C X D) Project Title: Vail Public Library Report date: 04/05/12 Data filename: C:\Brennan\Work\10030 Vail Public Library\Calculations\VPL Interior Lighting Comcheck 3-30-12.cckPage 2 of 6 Main Library ( Library 2775 sq.ft.)Linear Fluorescent 1: S1A: 3' 2 lamp strip / 48" T8 32W / Electronic21260720 Linear Fluorescent 2: S1B: 4' 2 lamp strip / 36" T8 25W / Electronic21250600 Compact Fluorescent 3: R2: LED retrofit lamp / Other / Electronic11011110 Compact Fluorescent 4: S4: LED Accent Light / Other / Electronic11828504 Linear Fluorescent 3: P4: Linear Fluor. pendant / 48" T8 32W / Electronic21560900 Compact Fluorescent 5: S6: LED Strip / Other / Electronic11053315 Track lighting 1: TA: Wattage based on 8.0 feet of track000240 Linear Fluorescent 4: S3: 1 lamp wall slot / 48" T8 32W / Electronic1730210 Compact Fluorescent 6: S2-E: CFL Surface Mount / Triple 4-pin 42W / Electronic1344132 Periodicals ( Library 450 sq.ft.)Compact Fluorescent 1 copy 1: P2: CFL Pendant / Triple 4-pin 42W / Electronic1344132 Linear Fluorescent 5: W1: Linear Wall Mount / 48" T8 32W / Electronic2260120 Linear Fluorescent 6: S3: 1 lamp wall slot / 48" T8 32W / Electronic1930270 Stacks ( Library 2012 sq.ft.)Compact Fluorescent 7: S4: LED Accent Light / Other / Electronic1428112 Linear Fluorescent 7: S3: 1 lamp wall slot / 48" T8 32W / Electronic12530750 Linear Fluorescent 8: S1A: 3' 2 lamp strip / 36" T8 25W / Electronic229501450 Linear Fluorescent 9: S1B: 4' 2 lamp strip / 48" T8 32W / Electronic222601320 Period and News ( Library 342 sq.ft.)Compact Fluorescent 8: S2: CFL Surface Mount / Triple 4-pin 42W / Electronic1344132 Linear Fluorescent 10: S3: 1 lamp wall slot / 48" T8 32W / Electronic1730210 Linear Fluorescent 11: S1A: 3' 2 lamp strip / 36" T8 25W / Electronic2250100 Linear Fluorescent 12: S1B: 4' 2 lamp strip / 48" T8 32W / Electronic2260120 Book Sales ( Retail 95 sq.ft.)Linear Fluorescent 13: P4: Linear Fluor Pendant / 48" T8 32W / Electronic2260120 Storage 4 ( Library 35 sq.ft.): Exempt Child Storage ( Library 52 sq.ft.): Exempt Book Sales Storage ( Library 90 sq.ft.): Exempt Storage 3 ( Library 107 sq.ft.): Exempt Sitting ( Library 955 sq.ft.)Compact Fluorescent 9: P1: LED Pendant / Other / Electronic117575 Compact Fluorescent 10: S4: LED Accent Light / Other / Electronic1628168 Compact Fluorescent 11: S2: CFL Surface Mount / Triple 4-pin 42W / Electronic1544220 Linear Fluorescent 14: W1: Linear Wall Mount / 48" T8 32W / Electronic2860480 Teen's Library ( Library 2275 sq.ft.)Linear Fluorescent 15: P3: Linear Fluor Pendant / 48" T8 32W / Electronic228601680 Compact Fluorescent 12: S4: LED Accent Light / Other / Electronic132884 Compact Fluorescent 13: S2: Triple 4-pin 42W / Electronic1644264 Classrooms ( Library 1067 sq.ft.)Linear Fluorescent 16: P3: Linear Flour Pendant / 48" T8 32W / Electronic21260720 Compact Fluorescent 14: S4: LED Accent Light / Other / Electronic1728196 Multipurpose Room ( Library 1370 sq.ft.)Track lighting 2: TA: Wattage based on 16.0 feet of track000480 Linear Fluorescent 17: P3: Linear Pendant / 48" T8 32W / Electronic220601200 Linear Fluorescent 28: W5: Linear wall washer / 48" T8 32W / Electronic1430120 Circulation ( Library 1720 sq.ft.)Compact Fluorescent 14: W4: CFL wall sconce / Triple 4-pin 42W / Electronic2988792 HID 1: R3: LED Handrail Luminaire / Other / Standard125375 Compact Fluorescent 15: P2: CFL pendant / Triple 4-pin 32W / Electronic1444176 Linear Fluorescent 18: S8: Strip light 4ft / 48" T8 32W / Electronic2360180 HID 2: R4: LED downlight / Other / Standard1920180 HID 3: S9: UC task Light / Other / Standard121836 Linear Fluorescent 21: S7: Strip light 3ft / 36" T8 25W / Electronic112525 Upper Office ( Library 1350 sq.ft.)Linear Fluorescent 19: R1: Rec 2x4 troffer 2lp / 48" T8 32W / Electronic21060600 Linear Fluorescent 20: W3: Linear wall sconce / 48" T8 32W / Electronic2560300 HID 4: R4: LED downlight / Other / Standard112020 HID 5: S9: UC task Light / Other / Standard111818 Linear Fluorescent 22: W1: Linear wall mount / 48" T8 32W / Electronic216060 Project Title: Vail Public Library Report date: 04/05/12 Data filename: C:\Brennan\Work\10030 Vail Public Library\Calculations\VPL Interior Lighting Comcheck 3-30-12.cckPage 3 of 6 Linear Fluorescent 23: W2: Linear vanity light / 24" T8 17W / Electronic113636 Lower Level ( Library 2066 sq.ft.)Linear Fluorescent 24: R1: Rec 2x4 troffer 1lp / 48" T8 32W / Electronic21360780 HID 6: S9: UC task light / Other / Standard12318414 Linear Fluorescent 25: S8: Strip light 4ft / 48" T8 32W / Electronic216060 Linear Fluorescent 26: S7: Strip light 3ft / 36" T8 25W / Electronic112525 Compact Fluorescent 16: R6: CFL recess / Triple 4-pin 42W / Electronic1334102 Linear Fluorescent 27: W5: Linear wall washer / 48" T8 32W / Electronic123060 Linear Fluorescent 29: W1: Linear wall sconce / 48" T8 32W / Electronic1260120 HID 7: R5: Rece LED downlight / Other / Standard121122 Linear Fluorescent 30: W2: Linear vanity light / 24" T8 17W / Electronic212424 Compact Fluorescent 17: S2: CFL Surface mount / Triple 4-pin 42W / Electronic124488 Total Proposed Watts =18447 Section 4: Requirements Checklist Lighting Wattage:❑1.Total proposed watts must be less than or equal to total allowed watts. Allowed Watts Proposed Watts Complies 21439 18447Passes Controls, Switching, and Wiring:❑2.Daylight zones under skylights more than 15 feet from the perimeter have lighting controls separate from daylight zones adjac ent to vertical fenestration.❑3.Daylight zones have individual lighting controls independent from that of the general area lighting. Exceptions:❑Contiguous daylight zones spanning no more than two orientations are allowed to be controlled by a single controlling device.❑Daylight spaces enclosed by walls or ceiling height partitions and containing two or fewer light fixtures are not required to h ave a separate switch for general area lighting.❑4.Independent controls for each space (switch/occupancy sensor). Exceptions:❑Areas designated as security or emergency areas that must be continuously illuminated.❑Lighting in stairways or corridors that are elements of the means of egress.❑5.Master switch at entry to hotel/motel guest room.❑6.Individual dwelling units separately metered.❑7.Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent o f the control of the nonexempt lighting.❑8.Each space required to have a manual control also allows for reducing the connected lighting load by at least 50 percent by e ither controlling all luminaires, dual switching of alternate rows of luminaires, alternate luminaires, or alternate lamps, switchin g the middle lamp luminaires independently of other lamps, or switching each luminaire or each lamp. Exceptions:❑Only one luminaire in space.❑An occupant-sensing device controls the area.❑The area is a corridor, storeroom, restroom, public lobby or sleeping unit.❑Areas that use less than 0.6 Watts/sq.ft.❑9.Automatic lighting shutoff control in buildings larger than 5,000 sq.ft. Exceptions:❑Sleeping units, patient care areas; and spaces where automatic shutoff would endanger safety or security.❑10.Photocell/astronomical time switch on exterior lights. Exceptions:❑Lighting intended for 24 hour use.❑11.Tandem wired one-lamp and three-lamp ballasted luminaires (No single-lamp ballasts). Exceptions:❑Electronic high-frequency ballasts; Luminaires on emergency circuits or with no available pair.NA YES YES NA NA YES YES YES YES NA YES Project Title: Vail Public Library Report date: 04/05/12 Data filename: C:\Brennan\Work\10030 Vail Public Library\Calculations\VPL Interior Lighting Comcheck 3-30-12.cckPage 4 of 6 Interior Lighting PASSES Section 5: Compliance Statement Compliance Statement: The proposed lighting alteration project represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application. The proposed lighting alteration project has been designed to meet the 2009 IECC, Chapter 8, requirements in COM check Version 3.9.0 and to comply with the mandatory requirements in the Requirements Checklist.Name - TitleSignatureDate Brennan Schumacher - Principal 04/05/12 Project Title: Vail Public Library Report date: 04/05/12 Data filename: C:\Brennan\Work\10030 Vail Public Library\Calculations\VPL Interior Lighting Comcheck 3-30-12.cckPage 5 of 6 COM check Software Version 3.9.0 Exterior Lighting Compliance Certificate 2009 IECC Section 1: Project Information Project Type: Alteration Project Title : Vail Public Library Exterior Lighting Zone: 2 (Neighborhood business district)Construction Site:Owner/Agent:Designer/Contractor:292 West Meadow Drive Vail, CO 81657 Town of Vail Vail, CO Brennan Schumacher David Nelson & Associates, LLC P.O. Box 270254 Littelton, CO 80127 303-730-2456 brennan@dnalighting.com Section 2: Exterior Lighting Area/Surface Power Calculation A Exterior Area/Surface B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts (B x C)F Proposed Watts Main Entry 1 (Main entry)8 ft of door width20Yes16036 Canopy Entry 1 (Entry canopy)270 ft20.25Yes6872 Main Entry 2 (Main entry)6 ft of door width20Yes12018 Canopy Entry 2 (Entry canopy)95 ft20.25Yes240 Emp Exit (Other door (not main entry))3 ft of door width20Yes6018 Sidewalk (Walkway < 10 feet wide)260 ft of walkway length0.7Yes182305 Plaza (Plaza area)1065 ft20.14Yes14974 Total Tradable Watts* =762523 Total Allowed Watts =762 Total Allowed Supplemental Watts** =600 * Wattage tradeoffs are only allowed between tradable areas/surfaces.** A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surface s.Section 3: Exterior Lighting Fixture Schedule A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/Fixture C # of Fixtures D Fixture Watt.E (C X D)Main Entry 1 ( Main entry 8 ft of door width): Tradable Wattage HID 1: R4-E: Square recessed LED downlight / Other / Standard121836 Canopy Entry 1 ( Entry canopy 270 ft2): Tradable Wattage HID 2: R4-E: Square recessed LED downlight / Other / Standard141872 Main Entry 2 ( Main entry 6 ft of door width): Tradable Wattage HID 3: R4-E: Square recessed LED downlight / Other / Standard111818 Canopy Entry 2 ( Entry canopy 95 ft2): Tradable Wattage Emp Exit ( Other door (not main entry) 3 ft of door width): Tradable Wattage HID 4: R4-E: Square recessed LED downlight / Other / Standard111818 Sidewalk ( Walkway < 10 feet wide 260 ft of walkway length): Tradable Wattage HID 5: R4-E: Sqaure recessed LED downlight / Other / Standard121836 HID 6: E1: Full cutoff LED Ped Pole / Other / Standard1272144 HID 9: W6-E: LED Wall Sconce / Other / Standard121020 Project Title: Vail Public Library Report date: 04/05/12 Data filename: C:\Brennan\Work\10030 Vail Public Library\Calculations\VPL Interior Lighting Comcheck 3-30-12.cckPage 6 of 6 HID 10: R3: LED Handrail Luminaire / Other / Standard1353105 Plaza ( Plaza area 1065 ft2): Tradable Wattage HID 7: R4-E: Square recessed LED downlight / Other / Standard131854 HID 8: W6: LED Wall Sconce / Other / Standard121020 Total Tradable Proposed Watts =523 Section 4: Requirements Checklist Lighting Wattage:❑1.Within each non-tradable area/surface, total proposed watts must be less than or equal to total allowed watts. Across all tra dable areas/surfaces, total proposed watts must be less than or equal to total allowed watts.Compliance:Passes.Controls, Switching, and Wiring:❑2.All exemption claims are associated with fixtures that have a control device independent of the control of the nonexempt ligh ting.❑3.Lighting not designated for dusk-to-dawn operation is controlled by either a a photosensor (with time switch), or an astronom ical time switch.❑4.Lighting designated for dusk-to-dawn operation is controlled by an astronomical time switch or photosensor.❑5.All time switches are capable of retaining programming and the time setting during loss of power for a period of at least 10 hours.Exterior Lighting Efficacy:❑6.All exterior building grounds luminaires that operate at greater than 100W have minimum efficacy of 60 lumen/watt.Exceptions:❑Lighting that has been claimed as exempt and is identified as such in Section 3 table above.❑Lighting that is specifically designated as required by a health or life safety statue, ordinance, or regulation.❑Emergency lighting that is automatically off during normal building operation.❑Lighting that is controlled by motion sensor.Exterior Lighting PASSES : Design 62% better than code.Section 5: Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2009 IECC requirements in COM check Version 3.9.0 and to comply with the mandatory requirements in the Requirements Checklist.Name - TitleSignatureDate Brennan Schumacher - Principal 04/05/12 YES NA YES YES YES YES