Loading...
HomeMy WebLinkAboutAppendix A Soil Laboratory ReportsAPPENDIX A SOIL LABORATORY REPORTS Black Diamond Resorts LLC ATCAssociates bic. Vail, Colorado 'gle 0� Report To: ATC Associates, Inc, Chris Woods 8985 E. Nichols Ave. Suite 350 Centennial CO 80112 - ph: (303) 799 -6100 tax: D'Anna Stelly Project Manager ATC Associates, Inc. Certificate of Analysis Number: 07030504 Project Name: Site: Site Address: PO Number: State: State Cert. No.: Date Reported: HOUSTON LABORATORY 8880 INTERCHANGE DRIVE HOUSTON, TX 77054 (713) 660 -0901 Vail Centennial, CO Colorado 311512007 This Report Contains A Total Of 31 Pages Excluding This Page VMS Chain Of Custody 3/15/2007 Date O Report To: ATC Associates, Inc. Chris Woods 8985 E. Nichols Ave. Suite 350 Centennial CO 80112 - ph: (303) 799 -6100 fax: HOUSTON LABORATORY 8880 INTERCHANGE DRIVE HOUSTON, TX 77054 (713) 660 -0901 Case Narrative for: ATC Associates, Inc. Certificate of Analysis Number: 07030504 Proiect Name: Site: Site Address: PO Number: State: State Cent. No.: Date Reported: Vail Centennial, CO Colorado 3/1512007 Results are reported on a wet weight basis unless dry- weight correction is denoted in the units field on the analytical report (" mglkg•dry " or uglkg -dry „ ). Matrix spike (MS) and matrix spike duplicate (MSD) samples are chosen and tested at random from an analytical batch of "like" matrix to check for possible matrix effect. The MS and MSD will provide site specific matrix data only for those samples which are spiked by the laboratory. Since the MS and MSD are chosen at random from an analytical batch, the sample chosen for spike purposes may or may not have been a sample submitted in this sample delivery group. The validity of the analytical procedures for which data is reported in this analytical report is determined by the Laboratory Control Sample (LCS) and the Method Blank (MB). The Laboratory Control Sample (LCS) and the Method Blank (MB) are processed with the samples and the MS /MSD to ensure method criteria are achieved throughout the entire analytical process. Some of the percent recoveries and RPD's on the QC report for the MS /MSD may be different than the calculated recoveries and RPD's using the sample result and the MS /MSD results that appear on the report because, the actual raw result is used to perform the calculations for percent recovery and RPD. Any other exceptions associated with this report will be footnoted in the analytical result page(s) or the quality control summary page(s). Please do not hesitate to contact us if you have any questions or comments pertaining to this data report. Please reference the above Certificate of Analysis Number. This report shall not be reproduced except in full, without the written approval of the laboratory. The reported results are only representative of the samples submitted for testing. SPL, Inc. is pleased to be of service to you. We anticipate working with you in fulfilling all your current and future analytical needs D'Anna Stelly Project Manager 07030504 Page 311512007 Date Test results meet all requirements of NELAC, unless specified in the narrative. O ATC Associates, Inc. Certificate of Analysis Number: 07030504 Report To: ATC Associates, Inc. Chris Woods 8985 E. Nichols Ave. Suite 350 Centennial CO 80112- ph: (303) 799 -6100 fax: (303) 799 -3441 Fax To: Project Name: Site: Site Address: HOUSTON LABORATORY 8880 INTERCHANGE DRIVE HOUSTON, TX 77054 (713) 660 -0901 Vail Centennial, CO PO Number: State: Colorado State Cert. No.: Date Reported: 3/15/2007 Client Sample ID 'EXC -1 -10 EXC-1 -20' _ ;EXC -1 -25' EXC -2 -10' 'EXC -2 -20' EXC -2 -25' jEXC -3 10' Lab Sample ID 07030504-01 1 07030504 -02 — Matrix Soil _....._. _ ...._ ...... Date Collected ... - -- -- Date Received COC ID HOLD 3/8/2007 3:00:00 PM 3/10/2007 10:00:00 AM 221042 ---2-21-0--4'2-- - ._.. .-[ Soil 3/8/2007 3:15:00 PM 3/8/2007 3:30:00 PM 3/10/2007 10:00:00 AM 3/1012007 10:00:00 AM 07030504 -03 07030504 -04 Soil 221042 Soil 3/8/2007 4:15:00 PM 3/8/2007 4:30:00 PM 3/10/2007 10:00:00 AM 3/10/2007 10:00:00 AM 221042 El 07030504 -05 07030504-06 Soil 221042 El Soff 3/8/2007 4:40:00 PM 3/10/2007 10:00:00 AM 3/10/2007 10:00:00 AM 221042 221042 07030504 -07 Soil 3/8/2007 5:00:00 PM D'Anne Stelly Project Manager Joel Grice Laboratory Director Ted Yen Quality Assurance Officer 3/15/2007 Date 07030504 Page 2 3/15/2007 11:01:01 AM HOUSTON LABORATORY 8880 INTERCHANGE DRIVE HOUSTON, TX 77054 (713) 660 -0901 Client Sample ID EXC -1 -10' Collected: 03/08/2007 15:00 SPL Sample ID: 07030504 -01 Site: Centennial, CO Analyses /Method Result QUAL MDL Rep.Limlt D11. Factor Date Analyzed Analyst Seq. #! DIESEL RANGE ORGANICS MCL CO_DRO Units: mglkg -dry Diesel Range Organics, C11- C28 1.2 J 0.71 15 1 03/11/07 21:20 NW 3715873 Surr. n- Pentacosane 108 0 % 20 -154 1 03/11/07 21:20 NW 3715873 Prep Method Prep Date Prep Initials Prep Factor SW3550B 03/10/200715:31 Pr 1.00 D'Anna Stelly Project Manager Qualifiers: ND /U - Not Detected at the Method Detection Limit J - Estimated Value between MDL and PQL >MCL - Result Over Maximum Contamination Limit(MCL) D - Surrogate Recovery Unreportable due to Dilution MI - Matrix Interference - Surrogate Recovery Outside Advisable QC Limits TNTC - Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 3 B - Analyte detected in the associated Method Blank above Rep.Limit 311512007 11:01,13 AM D'Anna Stelly Project Manager Qualifiers: ND /U - Not Detected at the Method Detection Limit >MCL - Result Over Maximum Contamination Limit(MCL) J - Estimated Value between MDL and PQL D - Surrogate Recovery Unreportabie due to Dilution MI - Matrix Interference - Surrogate Recovery Outside Advisable QC Limits TNTC - Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 4 B - Analyte detected in the associated Method Blank above Rep.Limit 311512007 11:01:13 AM HOUSTON LABORATORY 8880 INTERCHANGE DRIVE ® HOUSTON, TX 77054 (713) 660 -0901 Client Sample ID EXC -1 -10' Collected: 03/08/2007 15:00 SPL Sample ID: 07030504 -01 Site: Centennial, CO Analyses /Method Result QUAL MDL Rep.Limlt DII. Factor Date Analyzed Analyst Seq. # VOLATILE ORGANICS BY METHOI? 82608 MCL SW8260B Units: uglkg -dry Benzene ND 0.1 5.1 1 03/13/0711:41 DY 3718743 Ethylbenzene ND 0.14 5.1 1 03/13/0711:41 DY 3718743 Gasoline Range Organics _ND 9.9 51 1 03/13/07 11:41 DY 3718743 Toluene ND 0.18 5.1 1 03/13/0711:41 DY 3718743 Xylenes,Total ND 6.16 5.1 1 03113/0711:41 DY 3718743 Surr: 1,2- Dichloroethane -d4 93.5i 0 % 41 -155_ 1 03/13/0711:41 DY 3718743 Surr:4- Bromofluorobenzene u 97.5 0 % -64 -147 1 03!13/0711:41 DY_ 3718743 Surr: Toluene -d8 101 0 % 52 -152 1 03/13/07 11:41 DY 3718743 Preo Method Preo Date pre lnitials Preo Factor SW50308 03/12/200715:31 IDY 11.00 D'Anna Stelly Project Manager Qualifiers: ND /U - Not Detected at the Method Detection Limit >MCL - Result Over Maximum Contamination Limit(MCL) J - Estimated Value between MDL and PQL D - Surrogate Recovery Unreportabie due to Dilution MI - Matrix Interference - Surrogate Recovery Outside Advisable QC Limits TNTC - Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 4 B - Analyte detected in the associated Method Blank above Rep.Limit 311512007 11:01:13 AM lP HOUSTON LABORATORY 8880 INTERCHANGE DRIVE HOUSTON, TX 77054 (713) 660 -0901 Client Sample ID EXC -1 -10' Collected: 03/08/2007 15:00 SPL Sample ID: 07030504 -01 Site: Centennial, CO Analyses /Method Result QUAL MDL Rep.Limlt Dit. Factor Date Analyzed Analyst Seq. # PERCENT MOISTURE MCL D2216 Units: wt% Percent Moisture 2.79 0 0 1 03/10107 12:17 T L 3714717 D'Anna Stelly Project Manager Qualifiers: ND/U - Not Detected at the Method Detection Limit J - Estimated Value between MDL and PQL * - Surrogate Recovery Outside Advisable QC Limits >MCL - Result Over Maximum Contamination Limit(MCL D - Surrogate Recovery Unreportable due to Dilution MI - Matrix Interference TNTC - Too numerous to count E - Concentrations exceeding Calibration range of Instrument B - Analyte detected in the associated Method Blank above Rep.Limit 07030504 Page 5 3115/2007 11:01:14 AM O HOUSTON LABORATORY 8880 INTERCHANGE DRIVE HOUSTON, TX 77054 (713) 660 -0901 Client Sample ID EXC -1 -20' Collected: 03/08/2007 15:15 SPL Sample ID: 07030504 -02 Site: Centennial, CO Analyses /Method Result QUAL MDL Rep.Limit Dil. Factor Date Analyzed Analyst Seq. # DIESEL RANGE ORGANICS MCL C_O_DRO Units: mglkg -dry Diesel Range Organics, C11- C28 ND 0.88 19 u 1 03/11107 22:28 NW 3715876 Surr: n- Pentacosane 92.5 _ 0 % 20 -154 1 03/11/07 22:28 NW 3715876 Prep Method Prep Date Prep Initials Prep Factor SW3550B 03110/200715:31 JJDM 1.00 D'Anna Stelly Project Manager Qualifiers: ND /U - Not Detected at the Method Detection Limit >MCL - Result Over Maximum Contamination Limit(MCL) J - Estimated Value between MDL and PQL D - Surrogate Recovery Unreportable due to Dilution MI - Matra Interference * - Surrogate Recovery Outside Advisable QC Limits TNTC - Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 6 B - Analyte detected in the associated Method Blank above Rep.Limit 3/1512007 11:01:14 AM A ZOW HOUSTON LABORATORY 8880 INTERCHANGE DRIVE HOUSTON, TX 77054 (713) 660 -0901 Client Sample ID EXC -1 -20' Collected: 03/0812007 15:15 SPL Sample ID: 07030504 -02 Site: Centennial, CO Analyses /Method R Result QUAL M MDL R Rep.Limit D Dil. Factor Date Analyzed A Analyst S Seq. # VOLATILE ORGANICS BY METHOD 8260B M MCL SW8260B Units: u ug /kg -dry Benzene N NO 0 0.13 6 6.4 1 1 03/13/0712:03 D DY 3 3718744 Ethylbenzene 0 0.5 J 0 0.17 6 6.4 1 1 03/13/0712:03 D DY 3 3718744 ..... . ......-- - - - - -... - ....._..__._.. - -- .. — ._.._. .. Xylenes,Total Surr: 1,2- Dichioroethane -d4 Surr: 4- Bromofluorobenze n e Surr: Toluene -d8 0 -87 J 0.2 6.4 1 03113/0712:03 DY 3718744 93.5 41 -155 94.9 0 °h 64 -147 104 0 % 52 -152 Prep Method Prep Date Prep Initials Prep Factor SW50308 03/12/200715:33 DY 1.00 1 1 03/13/0712:03 DY 3718744 1 03/13/0712:03 DY 3718744 1 03/13/0712:03 DY 3718744 D'Anna Steily Project Manager Qualifiers: ND/U - Not Detected at the Method Detection Limit >MCL - Result Over Maximum Contamination Limlt(MCL) J - Estimated Value between MDL and PQL D - Surrogate Recovery Unreportable due to Dilution MI - Matra Interference - Surrogate Recovery Outside Advisable QC Limits TNTC - Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 7 B - Analyse detected in the associated Method Blank above Rep.Limit 31151200711:Oi:14AM ll� HOUSTON LABORATORY 8880 INTERCHANGE DRIVE HOUSTON, TX 77054 (713) 660 -0901 Client Sample ID EXC -1 -20' Collected: 03/08/2007 15:15 SPL Sample ID: 07030504 -02 Site: Centennial, CO Analyses /Method Result QUAL MDL Rep.Limit DII. Factor Date Analyzed Analyst Seq. # PERCENT MOISTURE MCL D2216 Units: wt %a Percent Moisture 21.7 0 0 1 03/10/0712 :17 T_L 3714716 D'Anna Stelly Project Manager Qualifiers: ND /U - Not Detected at the Method Detection Limit >MCL - Result Over Maximum Contamination Limit(MCL) J - Estimated Value between MDL and PQL D - Surrogate Recovery Unreportable due to Dilution MI - Matrix Interference * - Surrogate Recovery Outside Advisable QC Limits TNTC -Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 8 B - Analyte detected in the associated Method Blank above Rep.Limit 3/15/2007 11:01!15 AM HOUSTON LABORATORY 8880 INTERCHANGE DRIVE A zl� �� MA ® HOUSTON, TX 77054 (713) 660 -0901 Client Sample ID EXC -1 -25' Collected: 03/0812007 15:30 SPL Sample ID: 07030504 -03 Site: Centennial, CO Analyses /Method Result QUAL MDL Rep.Limit 1071. Factor Date Analyzed Analyst Seq. # DIESEL RANGE ORGANICS MCL CO_DRO Units: mglkg -dry Diesel Range Organics, C11- C28 ND 0.73 16 1 03/11/07 22:51 NW 3715877 Surr: n Pentacosane 102 0 % 20 -154 1 03/11/07 22:51 NW 3715877 Prep Method Prep Date Prep Initials Prep Factor SW3550B 03/101200715:31 JJDM 111.00 x-') - a..K� D'Anna Steily Project Manager Qualifiers: ND/U - Not Detected at the Method Detection Limit >MCL - Result Over Maximum Contamination Limit(MCL) J - Estimated Value between MDL and PQL D - Surrogate Recovery Unreportable due to Dilution MI - Matrix Interference * - Surrogate Recovery Outside Advisable QC Limits TNTC - Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 9 B - Analyte detected in the associated Method Blank above Rep.Limit 311512007 11:01:16 AM JR�ro,- AF P_ !;rw�ld 17) ;?0W HOUSTON LABORATORY 8880 INTERCHANGE DRIVE HOUSTON, TX 77054 (713) 660 -0901 Client Sample ID EXC -1 -25' Collected: 03108/2007 15:30 SPL Sample ID: 07030504 -03 Site: Centennial, CO Analyses /Method Result QUAL MDL Rep.Limit DII. Factor Date Analyzed Analyst Seq. # VOLATILE ORGANICS BY METHOD 8260B Benzene — ND MCL SW8260B Units: ug /kg -dry 0.11 5.3 1 03/1310712:25 DY 3718745 Ethylbenzene ND 0.15 5.3 1 03113/0712:25 DY 3718745 Gasoline Range Organics - ND _ -- 10 - - - -- - -- 53 - -- 1 - -- --------------- 03113/0712:25 DY -- 3718745 Toluene NO 0.18 5.3 1 03/1310712:25 DY 3718745 Xylenes,Total ND 0.17 __._...._.. 5.3 -_ ................................. 1 ........................__..... 03113/0712:25 DY - 3718745 Surr:1,2- Dichloroethane -d4 __ ............ 95.7 0 % 41 -155 1 03/13/0712:25 DY 3718745 . .. �_ —.... - — Surr:4- Bromofluorobenzene 97.4 0 % 64 -147 1 03113/0712:25 DY 3718745 Surr: Toluene -d8 104 0 % 52 -152 1 03113107 12:25 DY 3718745 Preo Method IPrea Date Prep Initials Prep Factor SW5030B 03/121200715:35 DY 1.00 D'Anna Stelly Project Manager Qualifiers: ND /U - Not Detected at the Method Detection Limit >MCL - Result Over Maximum Contamination Limit(MCL) J - Estimated Value between MDL and PQL D - Surrogate Recovery Unreportable due to Dilution MI - Matrix Interference Surrogate Recovery Outside Advisable QC Limits TNTC -Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 10 B - Analyte detected in the associated Method Blank above Rep.Limit 3115120071101:16 AM I HOUSTON LABORATORY 8880 INTERCHANGE DRIVE HOUSTON, TX 77054 (713) 660 -0901 Client Sample ID EXC -1 -25' Collected: 03/08/2007 15:30 SPL Sample ID: 07030504 -03 Analyses /Method PERCENT MOISTURE Percent Moisture Site: Centennial, CO Result QUAL MDL Rep.Limit DII. Factor Date Analyzed Analyst Seq. # MCL D2216 Units: wt% 5.8 0 0 1 03/10/0712:17 T_L 3714715 D'Anna Stelly Project Manager Qualifiers: ND /U - Not Detected at the Method Detection Limit >MCL - Result Over Maximum Contamination Umit(MCL) J - Estimated Value between MDL and PQL D - Surrogate Recovery Unreportable due to Dilution MI - Matrix Interference ' - Surrogate Recovery Outside Advisable QC Limits TNTC - Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 11 B - Analyte detected in the associated Method Blank above Rep.Limit 3r16r200711:o1:16AM HOUSTON LABORATORY 8880 INTERCHANGE DRIVE , zm� Z M Mc® HOUSTON, TX 77054 (713) 660 -0901 Client Sample ID EXC -2 -10' Collected: 03/08/2007 16:15 SPL Sample ID: 07030504 -04 Site: Centennial, CO Analyses /Method Result QUAL MDL Rep.Limit Dli. Factor Date Analyzed Analyst Seq. # DIESEL RANGE ORGANICS MCL CO�DRO Units: rggikS ry Diesel Range Organics, C11- C28 0.75 J 0.72 16 1 03/11/07 23:14 NW 3715878 Surr: n- Pentacosane 99.1 0 % 20 -154 1 03/11/07 23:14 NW 3715878 CPreo Mod Prep Date PreD Initials Prep Facto [SW35508 03/10/2D0715:31 JDM x1.00 J-,) - - D'Anna Stelly Project Manager Qualifiers: ND/U - Not Detected at the Method Detection Limit >MCL - Result Over Maximum Contamination Limit(MCL) J - Estimated Value between MDL and PQL D - Surrogate Recovery Unreportabie due to Dilution MI - Matrix Interference - Surrogate Recovery Outside Advisable QC Limits TNTC -Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 12 8 - Analyte detected in the associated Method Blank above Rep.Limit 3115=07 11.01:17 AM p HOUSTON LABORATORY 8880 INTERCHANGE DRIVE HOUSTON, TX 77054 (713)660.0901 Client Sample ID EXC -2 -10' Collected: 03/08/2007 16:15 SPL Sample ID: 07030504 -04 Site: Centennial, CO Analyses /Method Result QUAL MDL Rep.Limit DII. Factor Date Analyzed Analyst Seq. # VOLATILE ORGANICS BY METHOD 8260B MCL SW8260B Units: ug /kg -dry Benzene J NO 0.11 5.2 1 03/13/0712:47 DY 3718746 Ethylbenzene ND 0.14 5.2 1 03/13/0712:47 DY 3718746 Gasoline Range Organics ND 10 52 1 03M3107 12:47 DY 3718746 Toluene ND 0.18 5.2 1 03/13/0712:47 DY 3718746 Xylenes,Total ND 0.16 5.2 1 03113/0712:47 DY 3718746 Surr :1,2- Dichloroethane -d4 95.1 �� _ — 0 °% 41 -155 1 03/1310712:47 DY 3718746 Surr:4- Bromofluorobenzene 95.1 0 % 64 -147 1 03/13/0712:47 DY 3718746 Surr. Toluene -d8 101 (Prep Method Prep Date SW50306 03/12/200715:37 0 jPrev Initials IDY % 52 -152 jPrep Factor 11.00 1 03/13/07 12:47 DY 3718746 , D'Anna Steliy Project Manager Qualifiers: ND/U - Not Detected at the Method Detection Limit >MCL - Result Over Maximum Contamination Limit(MCL) J - Estimated Value between MDL and PQL D - Surrogate Recovery Unreportable due to Dilution MI - Matrix Interference " - Surrogate Recovery Outside Advisable QC Limits TNTC - Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 13 B - Analyse detected in the associated Method Blank above Rep.Limit 311612007 11:01:17 AM HOUSTON LABORATORY 8880 INTERCHANGE DRIVE ® HOUSTON, TX 77054 (713) 660 -0901 Client Sample ID EXC -2 -10' Collected: 03/08/2007 16:15 SPL Sample ID: 07030504 -04 Site: Centennial, CO Analyses /Method Result QUAL MDL Rep.Limit DII. Factor Date Analyzed Analyst Seq. # PERCENT MOISTURE MCL D2216 Units: wt% _ . . - -- Percent Moisture 3.96 0 0 1 03/10/0712:17 T L 3714714 jc) ' 6L'- � D'Anna Stelly Project Manager Qualifiers: ND/U - Not Detected at the Method Detection Limit >MCL - Result Over Maximum Contamination Limit(MCL) J - Estimated Value between MDL and PQL D - Surrogate Recovery Unreportable due to Dilution Ml - Matrix Interference - Surrogate Recovery Outside Advisable QC Limits TNTC - Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 14 B - Analyte detected in the associated Method Blank above Rep.Limit 3115/2007 11:01:17 AM HOUSTON LABORATORY 8880 INTERCHANGE DRIVE 060 ow'.® HOUSTON, TX 77054 'ZA (713} 660 -0901 Client Sample ID EXC -2 -20' Collected: 03/08/2007 16:30 SPL Sample ID: 07030504 -05 Site: Centennial, CO Analyses /Method Result QUAL MDL Rep.Limit Dil. Factor Date Analyzed Analyst Seq. # DIESEL RANGE ORGANICS MCL CO DRO Units: mglkg -dry Diesel Range Organics, C11- C28 0.88 J 0.74 16 1 03/11/07 23:37 NW 3715879 Surr: n- Pentacosane 107 0 % 20 -154 1 03/11/07 23:37 NW 3715879 Prep Method jPrep Date rep Inifials Prep Factor SW3550B 03/101200715:31 JDM 11.00 D'Anna Stelly Project Manager Qualifiers: ND/U - Not Detected at the Method Detection Limit >MCL - Result Over Maximum Contamination Limit(MCL) J - Estimated Value between MDL and PQL D - Surrogate Recovery Unreportable due to Dilution MI - Matrix Interference " - Surrogate Recovery Outside Advisable QC Limits TNTC - Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 15 B - Analyte detected in the associated Method Blank above Rep.Limit 311612007 11:01:18 AM HOUSTON LABORATORY 8880 INTERCHANGE DRIVE ® HOUSTON, TX 77054 (713) 660 -0901 Client Sample ID EXC -2 -20' Collected: 03/08/2007 16:30 SPL Sample ID: 07030504 -05 Site: Centennial, CO Analyses /Method Result QUAL MDL Rep.Llmit Dil. Factor Date Analyzed Analyst Seq. # VOLATILE ORGANICS BY METHOD 82608 MCL S 260 Units: uglkg -dry Benzene ND 0.11 5.3 1 03/13/0713:09 DY _`_ 3718747 Ethylbenzene ND 0.15 5.3 1 03/1310713:09 DY 3718747 Gasoline Range Organics ND 10 53 1 03/13/07 13:09 DY 3718747 Toluene ND 0.18 5.3 1 03113/0713:09 DY 3718747 Xylenes,Total ND 0.17 5.3 1 03/13/0713 :09 DY 3718747 Surr: 1,2- Dichloroethane -d4 93.8 0 % 41 -155 1 03/13/0713:09 DY 3718747 Surr:4- Bromofluorobenzene 95.0 _ 0 % 64 -147 1 03/13/0713:09 DY 3718747 Surr: Toluene -d8 100 0 % 52 -152 1 03/13/0713:09 DY 3718747 Prep Method Pre Date Prep Initials I� reD Factor SW5030B 03/12/200715:38 DY �1.00 D'Anna Stelly Project Manager Qualifiers: ND/U - Not Detected at the Method Detection Limit >MCL - Result Over Maximum Contamination Limit(MCL) J - Estimated Value between MDL and PQL D - Surrogate Recovery Unreportable due to Dilution MI - Matrix Interference ' - Surrogate Recovery Outside Advisable QC Limits TNTC -Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 16 B - Analyse detected in the associated Method Blank above Rep.Limit 3/15/2007 11:01:18 AM zm� �' MA C�o HOUSTON LABORATORY 8880 INTERCHANGE DRIVE HOUSTON, TX 77054 (713) 660 -0901 Client Sample ID EXC -2 -20' Collected: 03/08/2007 16:30 SPL Sample ID: 07030504 -05 Site: Centennial, CO Analyses/Method Result QUAL MDL Rep.Limit Dil. Factor Date Analyzed Analyst Seq. # PERCENT MOISTURE MCL D2216 Units: wt% Percent Moisture 6.39 0 0 1 03/10/07 12:17 T_L 3714713 D'Anna Stelly Project Manager Qualifiers: ND/U - Not Detected at the Method Detection Limit >MCL - Result Over Maximum Contamination Limit (MCL) J - Estimated Value between MDL and PQL D - Surrogate Recovery Unreportable due to Dilution MI - Matrix Interference ` - Surrogate Recovery Outside Advisable QC Limits TNTC - Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 17 B - Analyte detected in the associated Method Blank above Rep.Limit 3/1512007 11:01:19 AM )�::). 6L-"� -- D'Anna Stelly Project Manager Qualifiers: ND/U - Not Detected at the Method Detection Limit >MCL - Result Over Maximum Contamination Limit(MCL) J - Estimated Value between MDL and PQL D - Surrogate Recovery Unreportable due to Dilution MI - Matrix Interference * - Surrogate Recovery Outside Advisable QC Limits TNTC - Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 18 B - Analyse detected in the associated Method Blank above Rep.Limit 311612a0711:01:19AM HOUSTON LABORATORY zm� Z' 2r® 8880 INTERCHANGE DRIVE I M HOUSTON, TX 77054 (713) 660 -0901 Client Sample ID EXC -2 -25' Collected: 03/08/2007 16:40 SPL Sample ID: 07030504 -06 Site: Centennial, CO AnalysesfMethod Result QUAL MDL Rep.Limit Dil. Factor Date Analyzed Analyst Seq. # DIESEL RANGE ORGANICS MCL_ CO_DRO Units: mg1kg-dry _ Diesel Range Organics, C11- C28 0.87 J 18 1 03112/07 0:00 NW 3715880 Surr: n- Pentacosane 100 _0.81 0 % 20 -154 1 03112/07 0:00 NW 3715880 Prep Method Pre Da Le Prep Initials jPrep Factor SW3550B 03110/200715:31 JDM _- 1.00—A )�::). 6L-"� -- D'Anna Stelly Project Manager Qualifiers: ND/U - Not Detected at the Method Detection Limit >MCL - Result Over Maximum Contamination Limit(MCL) J - Estimated Value between MDL and PQL D - Surrogate Recovery Unreportable due to Dilution MI - Matrix Interference * - Surrogate Recovery Outside Advisable QC Limits TNTC - Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 18 B - Analyse detected in the associated Method Blank above Rep.Limit 311612a0711:01:19AM HOUSTON LABORATORY 8880 INTERCHANGE DRIVE HOUSTON, TX 77054 (713) 660 -0901 Client Sample ID EXC -2 -25' Collected: 03/08/2007 16:40 SPL Sample ID: 07030504 -06 xz) D'Anna Stelly Project Manager Qualifiers: ND /U - Not Detected at the Method Detection Limit >MCL - Result Over Maximum Contamination Limll(MCL) J - Estimated Value between MDL and PQL D - Surrogate Recovery Unreportable due to Dilution MI - Matrix Interference * - Surrogate Recovery Outside Advisable QC Limits TNTC - Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 19 B - Analyte detected in the associated Method Blank above Rep.Limit 3/1512007 11:01:19 AM Site: Centennial, CO Analyses /Method Result QUAL MDL Rep.Llmlt DII, Factor Date Analyzed Analyst Seq. # VOLATILE ORGANICS BY METHOD 8260B MCL SW8260B Units: ug /kg -dry Benzene ND 0.12 5.8 1 03/13/0713:31 DY 3718748 Ethylbenzene ND D.16 5.8 1 03/13/0713:31 DY 3718748 Gasoline Range Organics ND 11 58 1 03/13/0713:31 DY 3718748 Toluene ND 0.2 5.8 1 03/13/0713:31 DY 3718748 Xylenes,Total ND 0.18 5.8 1 03/13107 13:31 DY 3718748 Surr: 1,2- Dichloroethane -d4 96.7 0 k 41 -155 1 03/13/0713:31 DY 3718748 Surr: 4 Bromofluorobenzene 96.9 0 % 64 -147 1 03/13/07 13:31 DY 3718748 Surr: Toluene -d8 102 0 % 52 -152 1 03/13/07 13:31 DY 3718748 Prep Method Prep Date jPrep Initials Prep Factor 5W5030B _ . — 03/12/2007 15:39 IDY 11.00 xz) D'Anna Stelly Project Manager Qualifiers: ND /U - Not Detected at the Method Detection Limit >MCL - Result Over Maximum Contamination Limll(MCL) J - Estimated Value between MDL and PQL D - Surrogate Recovery Unreportable due to Dilution MI - Matrix Interference * - Surrogate Recovery Outside Advisable QC Limits TNTC - Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 19 B - Analyte detected in the associated Method Blank above Rep.Limit 3/1512007 11:01:19 AM HOUSTON LABORATORY oeor 8880 INTERCHANGE DRIVE 14060 ® HOUSTON, TX 77054 (713) 660 -0901 Client Sample ID EXC -2 -25' Collected: 03/08/2007 16:40 SPL Sample ID: 07030504 -06 Site: Centennial, CO Analyses /Method Result QUAL MDL Rep.Limit DII. Factor Date Analyzed Analyst Seq. # PERCENT MOISTURE MCL D2216 Units: wt% Percent Moisture 14.4 0 0 1 03/10/07 12:17 7—L 3714712 D'Anna Stelly Project Manager Qualifiers: ND/U - Not Detected at the Method Detection Limit >MCL - Result Over Maximum Contamination Limit(MCL) J - Estimated Value between MDL and PQL D - Surrogate Recovery Unreportabie due to Dilution MI - Matrix Interference * - Surrogate Recovery Outside Advisable QC Limits TNTC - Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 20 B - Analyte detected in the associated Method Blank above Rep.Limit 311512007 11:01z20AM HOUSTON LABORATORY 8880 INTERCHANGE DRIVE ® HOUSTON, TX 77054 (713) 660 -0901 Client Sample ID EXC -3 -10' Collected: 03/08/2007 17:00 SPL Sample ID: 07030504 -07 Site: Centennial, CO Analyses /Method Result QUAL MDL Rep.Limit Dil. Factor Date Analyzed Analyst Seq. # DIESEL RANGE ORGANICS _ MCL CO_DRO Units: m !g kg-dry___ Diesel Range Organics, C11- C28 3.6 J 0.93 20 1 03/12/071:09 NW 3715957 Surr: n Pentacosane 104 0 % 20 -154 1 03/12/07 1:09 NW 3715957 Prep Method lPrep Date Prep initials Prep Factor SW3550B M __ 03/10/2007 15:31 jJDM 11.00 D'Anna Stelly ^ : - -- -- - - - - -- Qualiflers: ND/U - Not Detected at the Method Detection Limit J - Estimated Value between MDL and PQL >MCL - Result Over Maximum Contamination Limit(MCL) D -Surrogate Recovery Unreportable due to Dilution MI - Matrix Interference *- Surrogate Recovery Outside Advisable QC Limits TNTC -Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 21 8 - AnWe detected in the associated Method Blank above Rep.Limit W1512007 11:01:21 AM Client Sample ID EXC -3 -10' HOUSTON LABORATORY 8880 INTERCHANGE DRIVE HOUSTON, TX 77054 (713) 660 -0901 Collected: 03/08/2007 17:00 SPL Sample ID: 07030504 -07 Site: Centennial, CO Analyses /Method Result QUAL MDL Rep.Limlt DII. Factor Date Analyzed Analyst Seq. # VOLATILE ORGANICS BY METHOD 8260B MCL S_ W8260B Units: Itglkg -dry Benzene 0.77 J 0.14 6.8 1 03/1310715:02 DY 3718808 Ethylbenzene 0.96 J 0.19 6.8 1 03/13/0715:02 DY 3718808 Gasoline Range Organics 32 J 13 68 1 03/13/07 15:02 DY 3718808 Toluene 3.1 J 0.23 —6-.8- 8 1 03/13/07 15:02 DY 3718808 Xylenes,Total 3.5 J 0.21 6.8 1 03113/0715:02 DY 3718808 urr:1,2- Dichloroethane -d4 93.9 0 % 41 -155 1 03/1310715:02 DY 3718608 Surr:4- BromoOuorobenzene 87.4 0 % 64 -147 1 03/1310715:02 DY 3718808 Surr: Toluene -d8 112 0 % 52 -152 1 03/13/07 15:02 DY 3718808 Prep Method Preo Date jPpep Initials Prep Factor f SW5030B 7 14 43 .......... 3320... _ DY 1 00 D'Anna Stelly Project Manager Qualifiers: ND/U - Not Detected at the Method Detection Limit >MCL - Result Over Maximum Contamination Limit(MCL) J - Estimated Value between MDL and POL D - Surrogate Recovery Unreportable due to Dilution MI - Matrix Interference ' - Surrogate Recovery Outside Advisable QC Limits TNTC - Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 22 B - Analyte detected in the associated Method Blank above Rep.Limit 311512007 1 tft21 AM O HOUSTON LABORATORY 8880 INTERCHANGE DRIVE HOUSTON, TX 77054 (713) 660 -0901 Client Sample 1D EXC -3 -10' Collected: 03/08/2007 17:00 SPL Sample ID: 07030504 -07 Analyses /Method PERCENT MOISTURE Percent Moisture Site: Centennial, CO Result QUAL MDL Rep.Limit Dil. Factor Date Analyzed Analyst Seq. #1 MCL D2216 Units: wt% 26.2 0 0 1 03110/0712:45 T_L 3714731 D'Anna Stelly Project Manager Qualifiers: ND /U - Not Detected at the Method Detection Limit >MCL - Result Over Maximum Contamination Limit(MCL) J - Estimated Value between MDL and PQL D - Surrogate Recovery Unreportable due to Dilution MI - Matrix Interference Surrogate Recovery Outside Advisable QC Limits TNTC - Too numerous to count E - Concentrations exceeding Calibration range of Instrument 07030504 Page 23 B - Analyte detected in the associated Method Blank above Rep.Limit 3115[2007 11:01:21 Arr