Loading...
HomeMy WebLinkAboutB12-0124 LOAD CALCS AK Electric Andy: 970-390-4975 Electrical Load Calc Brown Residence, Lodge at Vail Units 244/246 825 sf x 3w/ft=2475w Range8000w Microwave1200w Dishwasher1200w Disposal500w 2 SA circuits x 1500w3000w Total16,375w 16,375w -8,000= 8,375w 8,375w x 40%= 3,350w adjusted 3,350w + 8,000w = 11,350w Total Adjusted Load Add (2) bath head mats 800w additional 11,350w +800w = 12,150w Total Load 12,150w/208V= 58.4A