HomeMy WebLinkAboutB12-0124 LOAD CALCS
AK Electric
Andy: 970-390-4975
Electrical Load Calc
Brown Residence, Lodge at Vail Units 244/246
825 sf x 3w/ft=2475w
Range8000w
Microwave1200w
Dishwasher1200w
Disposal500w
2 SA circuits x 1500w3000w
Total16,375w
16,375w -8,000= 8,375w
8,375w x 40%= 3,350w adjusted
3,350w + 8,000w = 11,350w Total Adjusted Load
Add (2) bath head mats 800w additional
11,350w +800w = 12,150w Total Load
12,150w/208V= 58.4A