Loading...
HomeMy WebLinkAboutB12-0113 Plans corrections requiredGENERAL CONTRACTOR:ELECTRICAL CONTRACTOR:PLUMBING CONTRACTOR:ARCHITECT:OWNER:APPLICABLE BUILDING CODES STUMPF RESIDENCE REMODEL DRAWING INDEX GENERAL NOTES:675 LIONSHEAD PLACE, UNIT 455 & 452 VAIL COLORADO 81657 STRUCTURAL ENGINEER:BUILDING/ UNIT INFORMATION EXISTING:AREA - 3662 SF NET. BEDROOMS - 4 BATHS - 5.0 PROPOSED: AREA - 3662 SF NET. BEDROOMS - 4 BATHS - 5.0 CONSTRUCTION TYPE: 1B OCCUPANCY CLASSIFICATION: R-2 OCCUPANT LOADS: 8 (2 PEOPLE PER BEDROOM)FIRE SUPPRESSION: FULLY SPRINKLED JOEL STUMPF 675 LIONSHEAD PLACE UNIT 455 & 452 VAIL, COLORADO 81657 EMAIL: JBSTUMPF@GMAIL.COM CONTACT: JOEL STUMPF TBD TBD TBD TBD TEL: TBD FAX: TBD CONTACT: TBD AW INTERIORS 210 EDWARDS VILLAGE BLVD EDWARDS, CO 81632 CONTACT: CHRIS BROOK 970.926.4994 OR CELL 970.390.7750 TBD TBD DO NOT SCALE DRAWINGS NOT APPLICABLE 2003 INTERNATIONAL BUILDING CODE 2003 INTERNATIONAL PLUMBING CODE 2003 INTERNATIONAL FIRE CODE 2008 NATIONAL ELECTRICAL CODE TOWN OF VAIL AMENDMENTS TO THE ABOVE REFERENCED CODES SHEET NUMBER:SHEET NAME:IA-0.0 COVER SHEET IA-1.0 DEMO FLOOR PLAN IA-1.1 DEMO REFLECTED CEILING PLAN IA-1.2 FLOOR PLAN IA-1.21 FLOOR FINISH PLAN IA-1.3 REFLECTED CEILING PLAN PROJECT DESCRIPTION:PROJECT SCOPE CONSISTS OF THE RENOVATION OF A SINGLE STORY CONDOMINIUM. WORK INCLUDES REPLACEMENT OF EXISTING PLUMBING AND LIGHTING FIXTURES THROUGHOUT. THE ADDITION OF MILLWORK IN THE CORRIDOR, KITCHEN, DINING AND BEDROOMS. THE ADDITION OF A STEAM UNIT IN THE POWDER ROOM AND A NEW SHOWER CONFIGURATION IN THE MASTER BATHROOM.VERIFY ALL DIMENSIONS, CONDITIONS AND UTILITY LOCATIONS ON THE JOB PRIOR TO BEGINNING ANY WORK OR ORDERING OF ANY MATERIALS. NOTIFY THE DESIGNER OF ANY CONFLICTS OR DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY.AREAS OF CONFLICT OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN APPROVAL FROM THE DESIGNER BEFORE CONSTRUCTION CONTINUES.PLAN DIMENSIONS ARE FROM FACE OF FINISHED MATERIAL UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE FROM FACE OF FINISHED MATERIALS UNLESS OTHERWISE NOTED.PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL MOUNT FIXTURES, TOILETS, TOILET ACCESSORIES, CABINETRY, COUNTERTOPS,SHELVES, CLOSET RODS AND ARTWORK.COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING,FLOOR, WALLS AND OTHERWISE DESIGNATED SPACES. VERIFY WITH DESIGNER WHEN CHANGING CONFIGURATIONS NOTED ON DRAWINGS.VERIFY ELECTRICAL ROUGH-IN LOCATIONS FOR ALL APPLIANCES AND LIGHT FIXTURES.IMMEDIATELY NOTIFY THE DESIGNER OF ANY CONFLICTS OR DISCREPANCIES WITH THE INFORMATION PROVIDED HEREIN OR WITH EXISTING FIELD CONDITIONS.VERIFY PLUMBING ROUGH-IN LOCATIONS FOR ALL APPLIANCES AND FIXTURES.IMMEDIATELY NOTIFY THE DESIGNER OF ANY CONFLICTS OR DISCREPANCIES WITH THE INFORMATION PROVIDED HEREIN OR WITH EXISTING FIELD CONDITIONS.IN THE EVENT THAT ADDITIONAL DETAIL OR GUIDANCE IS NEEDED BY THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECT OF THIS PROJECT, HE SHALL IMMEDIATELY NOTIFY THE DESIGNER. FAILURE TO GIVE AMPLE NOTICE SHALL RELIEVE THE DESIGNER OF RESPONSIBILITY FOR DELAYS TO THE PROJECT.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. THIS PROJECT IS GOVERNED BY THE 2003 INTERNATIONAL BUILDING CODE. COMPLIANCE IS MANDATORY. THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT WORK THAT DOES NOT CONFORM TO CODE.THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL FIELD COORDINATE AND OBTAIN APPROVAL FROM THE ENGINEER BEFORE CUTTING, NOTCHING OR DRILLING OF ANY CAST-IN-PLACE CONCRETE, STEEL FRAMING OR ANY OTHER STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE BUILDING.ALL ELECTRICAL WORK IN THIS PROJECT IS TO BE COMPLETED IN A WORKMAN LIKE FASHION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE 2008 NATIONAL ELECTRIC CODE. ELECTRICAL CONTRACTOR IS TO CONFIRM PLUGS, SWITCHES, PLATES AND PLATE COLORS PRIOR TO INSTALLATION.ALL PLUMBING AND VENTILATION WORK IN THIS PROJECT IS TO BE COMPLETED IN A WORKMAN LIKE FASHION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE 2003 INTERNATIONAL MECHANICAL CODE, 2003 INTERNATIONAL PLUMBING CODE, AND 2003 INTERNATIONAL FIRE CODE.SUBSTITUTIONS FOR "EQUAL" PRODUCTS WILL BE ACCEPTABLE ONLY WITH THE OWNERS AND/ OR THE DESIGNERS WRITTEN APPROVAL.IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS, TRANSPORTATION,SUPPLIES, EQUIPMENT, CLEANUP, ETC. TO OBTAIN A COMPLETED JOB WITHIN THE RECOGNIZED STANDARDS OF THE INDUSTRY.COORDINATE ALL CABINETRY CONFIGURATIONS WITH THE DESIGNER PRIOR TO ROUGH-IN.COORDINATE ALL TRIM PROFILES AND CONFIGURATIONS WITH THE DESIGNER.COORDINATE ALL INTERIOR FINISHES WITH THE DESIGNER.1.2.3.4.5.6.7.8.9.10.11.12.13.14.15.16.17.18.IA-3.0 ELEVATIONS IA-3.1 ELEVATIONS IA-3.2 ELEVATIONS IA-4.0 SECTIONS & DETAILS IA-3.3 ELEVATIONS DESIGNER:SLIFER DESIGNS 216 MAIN STREET SUITE C-100 EDWARDS, COLORADO 81632 TEL: 970.926.8200 FAX: 970.926.8228 CONTACT: KIM TOMS B12-0113 Received By Shelley Bellm at 8:42 am, Apr 19, 2012 452.02 MASTER BEDROOM 452.06 TERRACE 455.24 BUNK BATHROOM 452.01 ENTRY 455.52 VESTIBULE 455.36 CLOSET 455.08 BUNK ROOM 455.35 CLOSET 455.07 GUEST BEDROOM 455.23 GUEST BATHROOM 455.21 POWDER ROOM 455.32 LAUNDRY 455.34 CLOSET 455.51 CORRIDOR 455.01 ENTRY 455.31 CLOSET 455.33 CLOSET 455.22 MICHILLE'S BATHROOM 455.06 MICHILLE'S BEDROOM 455.02 KITCHEN 455.03 DINING 455.62 TERRACE 455.61 TERRACE 455.04 LIVING ROOM 452.04 CLOSET REMOVE EXISTING GYPSUM BOARD.DO NOT DISTURB STRUCTURAL COLUMN OR FIREPROOFING EXISTING FIREBOX TO BE RE-USED AT EXISTING LOCATION REMOVE EXISTING SINK, FAUCET AND DISPOSAL REMOVE EXISTING COUNTERTOP SLAB - DO NOT DISTURB CABINET BOXES REMOVE EXISTING ISLAND SLAB REMOVE EXISTING MICROWAVE & DISHWASHER - SALVAGE FOR REUSE REMOVE EXISTING STONE HEARTH,WOOD MANTLE,AND BASE TRIM REMOVE EXISTING GYPSUM BOARD AND FRAMING REMOVE EXISTING FAUCET (2)AND SINK (2)REMOVE EXISTING BATH HARDWARE THROUGHOUT REMOVE EXISTING SHOWER ENCLOSURE,DOOR AND HARDWARE REMOVE EXISTING TUB, TUB FILLER AND DRAIN ASSEMBLY REMOVE EXISTING SHOWER HEAD,VALVE, TRIM AND DRAIN ASSEMBLY REMOVE EXISTING SHOWER TILE,CEMENTITIOUS BACKER, AND SHOWER PAN REMOVE EXISTING TUB DECK, TILE AND FRAMING REMOVE EXISTING ISLAND CABINETRY REMOVE EXISTING WALL MIRROR AND SCONCES REMOVE EXISTING WALL MIRROR REMOVE EXISTING FIREBOX - SALVAGE FOR REUSE REMOVE EXISTING STONE HEARTH,AND BASE TRIM REMOVE EXISTING GYPSUM BOARD AND FRAMING 452.03 MASTER BATHROOM REMOVE EXISTING CLOSET SHELVING REMOVE EXISTING CABINET & DRAWER PANELS - DO NOT DISTURB CABINET & DRAWER BOXES EXISTING DISPOSAL TO BE USED AT NEW LOCATION REMOVE EXISTING RANGE HOOD REMOVE EXISTING TOILET REMOVE EXISTING SHOWER HEAD REMOVE EXISTING TOILET REMOVE EXISTING SHOWER HEAD REMOVE EXISTING TOILET REMOVE EXISTING SHOWER HEAD REMOVE EXISTING TOILET REMOVE EXISTING SHOWER HEAD REMOVE EXISTING REFRIGERATOR NORTH DESIGNATES FIXED FINISHES AND COMPONENTS TO BE DEMOLISHED LEGEND DESIGNATES FLOOR SURFACES AND COMPONENTS TO BE DEMOLISHED DESIGNATES WALLS TO BE DEMOLISHED DESIGNATES EXISTING CONSTRUCTION AND FIXED FINISHES 452.02 MASTER BEDROOM 452.06 TERRACE 452.03 MASTER BATHROOM 455.24 BUNK BATHROOM 452.01 ENTRY 455.52 VESTIBULE 455.36 CLOSET 455.08 BUNK ROOM 455.35 CLOSET 455.07 GUEST BEDROOM 455.23 GUEST BATHROOM 455.21 POWDER ROOM 455.32 LAUNDRY 455.34 CLOSET 455.51 CORRIDOR 455.01 ENTRY 455.31 CLOSET 455.33 CLOSET 455.22 MICHILLE'S BATHROOM 455.06 MICHILLE'S BEDROOM 455.02 KITCHEN 455.03 DINING 455.62 TERRACE 455.61 TERRACE 455.04 LIVING ROOM 452.04 CLOSET REMOVE EXISTING CROWN REMOVE EXISTING LIGHT FIXTURE REMOVE EXISTING DIRECTIONAL LIGHT CAN (2)REMOVE EXISTING CROWN, GYPSUM BOARD REMOVE EXISTING CROWN REMOVE EXISTING LIGHT FIXTURE REMOVE EXISTING GYPSUM BOARD AND NON-STRUCTURAL FRAMING REMOVE EXISTING UNDER CABINET LIGHT FIXTURES (3)REMOVE EXISTING CROWN REMOVE EXISTING LIGHT FIXTURE REMOVE EXISTING LIGHT CAN (2)REMOVE EXISTING J-BOX REMOVE EXISTING LIGHT FIXTURE (2)REMOVE EXISTING ACCESS PANEL & HVAC EQUIPMENT - SALVAGE FOR REUSE. (EXTENT OF HVAC EQUIPMENT DEMO TO BE DETERMINED IN THE FIELD)REMOVE EXISTING LIGHT CAN REMOVE EXISTING GYPSUM BOARD REMOVE EXISTING LIGHT CAN (2)REMOVE EXISTING GYPSUM BOARD REMOVE EXISTING GYPSUM BOARD AND NON-STRUCTURAL FRAMING REMOVE EXISTING LIGHT FIXTURE (2)& J-BOX/POWER SUPPLY NORTH DESIGNATES FIXED FINISHES AND COMPONENTS TO BE DEMOLISHED LEGEND DESIGNATES OVERHEAD SURFACES AND COMPONENTS TO BE DEMOLISHED DESIGNATES EXISTING CONSTRUCTION AND FIXED FINISHES 452.02 MASTER BEDROOM 452.06 TERRACE 452.03 MASTER BATHROOM 455.24 BUNK BATHROOM 452.01 ENTRY 455.52 VESTIBULE 455.36 CLOSET 455.08 BUNK ROOM 455.35 CLOSET 455.07 GUEST BEDROOM 455.23 GUEST BATHROOM 455.21 POWDER ROOM 455.32 LAUNDRY 455.34 CLOSET 455.01 ENTRY 455.31 CLOSET 455.33 CLOSET 455.22 MICHILLE'S BATHROOM (TYPE B BATHROOM)455.06 MICHILLE'S BEDROOM 455.02 KITCHEN 455.03 DINING 455.62 TERRACE 455.61 TERRACE 452.04 CLOSET 452.05 CLOSET 6'-6 1 2 "4 1 2 "1'-4"6'-8 1 2 "3'-0"4"1'-3 1 2 "455.51 CORRIDOR 2'-0"1"7'-7 1 2 "11"6'-9"1'-5 1 2 "2'-10"12'-0"6'-2"2'-11 1 2 "6"1'-1 1 2 "4'-2"1'-1 1 2 "1'-0"1'-0"5'-9"EQ EQ EQ EQ LINE REPRESENTS EXTENT OF NEW HEADER ABOVE TUB EQ EQ EQ EQ C L OF PLUMBING FIXTURES AND SHOWER C L OF PLUMBING FIXTURE AND SHOWER DOOR 6"4'-0"NEW FIREPLACE HEARTH, MANTLE AND SURROUND NEW FIREPLACE HEARTH,MANTLE AND SURROUND NEW ISLAND COUNTERTOP AND CABINETS NEW COUNTERTOP NEW BUILT-INS NEW UNDER COUNTER WINE COOLER C IA-3.0 3'-7"CLEAR 1 IA-4.0 3'-5"CLEAR RADIUS: 14'-8 1/2"3'-7 1 2 "455.04 LIVING ROOM H IA-3.0 F I G IA-3.1 E D D IA-3.2 A IA-3.3 B IA-3.3 C IA-3.2 A B E IA-3.2 F IA-3.2 G IA-3.3 E D F IA-3.0 A B LINE REPRESENTS EXTENT OF NEW HEADER ABOVE TUB 2'-2"NORTH NOTES 1. NEW PLUMBING FIXTURES AND DRAIN TRIM TO BE INSTALLED AT EXISTING LOCATIONS, U.O.N.2. ALL NEW INTERIOR PARTITIONS AND INTERIOR WALL IN FILL ARE TO BE CONSTRUCTED USING STEEL STUDS AS REQUIRED FOR TYPE IB CONSTRUCTION. 452.02 MASTER BEDROOM 452.06 TERRACE 452.03 MASTER BATHROOM 455.24 BUNK BATHROOM 452.01 ENTRY 455.52 VESTIBULE 455.36 CLOSET 455.08 BUNK ROOM 455.35 CLOSET 455.07 GUEST BEDROOM 455.23 GUEST BATHROOM 455.21 POWDER ROOM 455.32 LAUNDRY 455.34 CLOSET 455.01 ENTRY 455.31 CLOSET 455.33 CLOSET 455.22 MICHILLE'S BATHROOM 455.06 MICHILLE'S BEDROOM 455.02 KITCHEN 455.03 DINING 455.62 TERRACE 455.61 TERRACE 455.04 LIVING ROOM 452.04 CLOSET 452.05 NEW CLOSET NEW SHOWER FLOOR TILE - 4" x 4"EMPERADOR DARK 455.51 CORRIDOR REF.:30"x48"SINK.:30"x48"D.W.:30"x48"RANGE/OVEN:30"x48"WINE:30"x48"TUB:30"x60"LAV.:30"x48"W.C.:48"x56"1'-6"NORTH 452.02 MASTER BEDROOM 452.06 TERRACE 455.24 BUNK BATHROOM 452.01 ENTRY 455.52 VESTIBULE 455.36 CLOSET 455.08 BUNK ROOM 455.35 CLOSET 455.07 GUEST BEDROOM 455.21 POWDER ROOM 455.32 LAUNDRY 455.34 CLOSET 455.51 CORRIDOR 455.01 ENTRY 455.31 CLOSET 455.33 CLOSET 455.22 MICHILLE'S BATHROOM 455.02 KITCHEN 455.62 TERRACE 455.61 TERRACE 452.04 CLOSET 3'-3 1 2 "1'-4"TBD TBD EQ 3'-11 1 2 "EQ EQ EQ EQ EQ 3'-11 1 2 "6'-3"6'-5 1 2 "11'-2 1 2 "2'-8"1'-2"6'-8 1 2 "EQ 455.03 DINING EQ EQ EQ 4'-4"5'-3"4'-4"4'-4"5'-3"4'-4"EQ EQ EQ EQ LINE REPRESENTS EXTENT OF EXISTING KITCHEN SOFFIT 4'-0"10'-7"1'-6"1'-6"2'-2"EQ EQ EQ EQ NEW VANITY SCONCE TO BE INSTALLED AT NEW J-BOX/ POWER SUPPLY LOCATIONS 455.06 MICHILLE'S BEDROOM NEW LIGHT FIXTURE NEW HEADER ABOVE TUB - ALIGN WITH ADJACENT WALL 455.23 GUEST BATHROOM 455.04 LIVING ROOM 452.03 MASTER BATHROOM FIXTURE TYPE AND LOCATION OF CEILING MOUNTED DIRECTIONAL LIGHTING TBD PERIMETER LIGHTING ABOVE CROWN PERIMETER LIGHTING ABOVE CROWN 452.05 CLOSET ADD CROWN AND RETURN INTO WINDOW TREATMENT VALANCES WOOD PANEL SOFFIT COFFER WITH WOOD PANELING AND BOX BEAMS COFFER CEILING WITH WOOD PANELING FINISH BARREL VAULT CEILING WITH LEVEL 5 DRYWALL FINISH LINE REPRESENTS EXTENT OF NEW SOFFIT ABOVE 3 NEW RECESSED CANS LOCATIONS TBD IN THE FIELD UPPER CABINET LIGHTING -LOCATION AND TYPE TBD DOWNLIGHT AT BUILT-IN 3'-8"4'-11 1 2 "NEW LIGHT FIXTURE EQ EQ AW 6 AW 6 6"6"ADD CROWN NORTH NOTES 1. NEW LIGHTING FIXTURES TO BE INSTALLED AT EXISTING J-BOX/ POWER SUPPLY LOCATIONS, U.O.N.2. ALL NEW INTERIOR CEILING COMPONENTS ARE TO BE CONSTRUCTED USING STEEL STUDS AS REQUIRED FOR TYPE IB CONSTRUCTION. PERIMETER LIGHTING ABOVE CROWN COLUMN PANEL AND APPLIED MOLDING (TO MATCH ARCH AT MASTER ENTRY)WOOD PANELED WAINSCOT (TYPICAL -PERIMETER OF ENTRY)GYPSUM BOARD - PAINT BARREL VAULT CEILING LEVEL 5 DRYWALL FINISH WOOD FIREPLACE SURROUND AND MANTLE EXISTING GAS FIRE BOX STONE SLAB HEARTH STONE VENEER 4'-5 1 2 "1'-6"8"3'-4"11 1 2 "FIELD LOCATE 4"PAINTED DRYWALL FIELD LOCATE SN 1 (STONE VENEER)SN 1 (STONE VENEER)AW 3 LTG 4 2'-10 1 2 "4'-0"STAINED ALDER WOOD BACKS (TYPICAL)ADJUSTABLE SHELVES (TYPICAL)FIXED SHELF ABOVE CHROME ROD ADJUSTABLE SHELF STAINED ALDER WOOD BACKS (TYPICAL)5'-8 1 2 "ADJUSTABLE SHELVES (TYPICAL)ADJUSTABLE SHELVES (TYPICAL)REMOVABLE ROD & SHELVES ADJUSTABLE SHELVES (TYPICAL) PAINTED DRYWALL 5'-5 1 2 "(LIGHT SCONCE)C L OF SCONCE AND MIRROR 5'-6"3'-9"EQ EQ SLAB SHELF TO MATCH VANITY SLAB NEW SHOWER TILE EMPERADOR LIGHT (TO MATCH EXISTING BATH FLOOR)3'-0"6"2'-10"2'-10"1'-6"4'-0"7'-0"LTG 4 PLU 10 12 PLU 13 PLU AW 7 REVISED EXISTING MIDDLE LARGE DRAWER TO 2 SMALLER EQUAL DRAWERS ADD TRIM PIECE TO CONNECT 2 ONE CONTINUOUS SLAB TOP & BACKSPLASH NEW STAINED WOOD ADJUSTABLE SHELVES NEW FIXED SHELF TO MATCH EXISTING SHORTEN EXISTING ROD TO ACCOMMODATE NEW BUILT-IN NEW FIXED SHELF TO MATCH EXISTING 2'-6"2'-4"1'-8"2'-6"NEW BUILT-IN CHEST OF DRAWERS ALDER - STAINED TO MATCH BASE/TRIM/DOORS 1'-4"2'-6"1'-4"1'-8" LEADED "AMBER GLASS"CABINET PANEL NEW CABINET DOOR AND DRAWER FACES WOOD LIGHT VALANCE (WARM LED U/C LIGHTS)CROWN @ CABINET TO MATCH CABINET STAIN TWO ADJUSTABLE WOOD EDGE W/GLASS CENTER ADJUSTABLE SHELVES CABINET LIGHT RAISED PANELING (WRAPS SIDE OF REFRIGERATOR)AW 4 ST 6 ST 7 CHW 5 CHW 4 AW 2 WOOD SIDES WINE STORAGE WOOD ARCH JAMB (FINISHED THE SAME AS ENTRY TO MASTER BEDROM)A 3 A 2 &A 4 WOOD PANELS TO MATCH CABINET ON NEW REFRIGERATOR WOOD PANEL AT REFRIGERATOR SIDE CABINET MANUFACTURER TO INSURE LIGHT RAIL LOCATION COMPLIES WITH LOCAL FIRE CODE WOOD EDGE W/GLASS CENTER ADJUSTABLE SHELVES RECESSED CAN LIGHT PAINTED DRYWALL NEW CABINET DOORS AND DRAWER FACES WOOD CLAD PILASTER CROWN TO MATCH WINDOW CASE STAIN CHW 4 ALDER "NOODLE"PIECE TO INFILL BETWEEN CROWN AND WINDOW CASE STAINED TO MATCH WINDOW CASE STAIN AW 8 ST 6 ST 7 GEORGIAN COLUMN ON 45 DEGREE CORNER OPERABLE CABINETS BELOW COUNTER DOUBLE OGEE OVER FULL BULLNOSE LAMINATED COUNTERTOP EDGE FINISHED END PANEL TO MATCH CABINETS MICRO SLAB BACK SPLASH TO MATCH COUNTER TOP FULL WOOD PANELING SINGLE OGEE OVER FULL BULLNOSE LAMINATED COUNTERTOP EDGE PLU 20 PLU 22 DOUBLE OGEE OVER FULL BULLNOSE LAMINATED COUNTERTOP EDGE AT UPPER ENTIRE 42" COUNTER 3'-6"GEORGIAN COLUMN ON 45 DEGREE CORNER FULL WOOD PANELING 3'-6"GEORGIAN COLUMN ON 45 DEGREE CORNER 3'-6"3'-0"STONE BACK SPLASH TO MATCH COUNTER TOP A 1 WOOD SHELF NOSING WITH PROFILE WOOD AT BACK WALL COLUMN PANEL AND APPLIED MOLDING (TO MATCH ARCH AT MASTER ENTRY)PROFILED WOOD TOP CABINET WITH ADJUSTABLE SHELVING RECESSED CAN WOOD WINE RACK PAINTED DRYWALL (TEXTURE TO MATCH EXISTING WALLS) WOOD PANELING COFFER WITH WOOD PLANKING 5'-6"EQUAL EQUAL 3'-6 1 2 "1'-1"7'-7 1 2 "11'-9 1 2 "1'-1"1'-3 1 2 "1'-9"8"OUTLET SN 3 SN 2 1'-2 1 2 "ALDER "NOODLE"PIECE TO INFILL BETWEEN CROWN AND WINDOW CASE STAINED TO MATCH WINDOW CASE STAIN (TYPICAL AT PERIMETER OF ROOM)EXISTING GAS FIRE BOX STONE SLAB 6'-3"6'-9"SN 2 5'-3"7'-0"4'-4 1 2 "EXISTING HEIGHT J-BOX (2)FOR SCONCE J-BOX (2)FOR SCONCE COFFER WITH WOOD PLANKING ADJUSTABLE SHELVES (TYPICAL)WOOD BACKS AND SIDES (TYPICAL)EXISTING ROD AND SHELF 4'-3"NEW PARTITION AND SHELF TO SLIDE OUT FOR ACCESS TO FCU HOOKS (CONFIRM QUANTITY AND LOCATIONS W/OWNER AFTER NEW SHELVING AND BUILT-INS ARE INSTALLED)6"11"11"5'-6"3'-6"11 1 2 "11"HOOK 5'-6"EQ EQ EXISTING FCU ACCESS PANEL EXISTING FCU ACCESS PANEL