Loading...
HomeMy WebLinkAboutB12-0123 Plans approved1.2 1.3 2.3 2.2 2.4 2.5 2.6 2.9 2.11 1.1 2.1 2.8 2.10 AA BB A 2.12 B 2.7 1.4 SCALE:LEVEL 03 ELECTRICAL PLAN 1/8" = 1'-0"FLAG NOTES:NOTES:COPYRIGHT 2010 B ANZE G EAUDIN (970)949-6108 (530)550-7334 (303) 278-3820 (970) 221-5691 (505) 323-9070 Vail:Lake Tahoe:Denver:Fort Collins:Albuqu erque:www.bgce.com ISS. #ARCHITECT'S PROJECT NO. :KEY PLAN DESCRIPTION DATE 21064.04 OWNER 4240 ARCHITECTURE INC 3003 LARIMER STREET DENVER, CO 80205 ARCHITECT t: 303.292.3388 copyright 2010 f: 303.292.3113 VAIL, COLORADO TOWN OF VAIL DEPARTMENT OF PUBLIC WORKS 1309 ELKHORN DRIVE VAIL, CO 81632 ALPINE ENGINEERING INC.34510 U.S. 6 UNIT A9 EDWARDS, CO 81632 CIVIL ENGINEER PEAK LAND CONSULTING , INC.1000 LIONSRIDGE LOOP VAIL, CO 81675 SURVEYOR MARTIN/MARTIN, INC.12499 WEST COLFAX AVE.LAKEWOOD, CO 80215 STRUCTURAL ENGINEER BEAUDIN GANZE CONSULTING ENGINEERS, INC.222 CHAPEL PLACE UNIT AC-201 AVON, CO 81620 MEP ENGINEER t: 970.479.2158 f:970-926-3390 t: 970.926.3373 t: 970.476.8644 t: 303.431.6100 t: 970.949.6108 LIONSHEAD TRANSIT WELCOME CENTER MARY HART DESIGN POST OFFICE BOX 8528 BRECKENRIDGE, CO 80424 LANDSCAPE ARCHITECT t: 970.389.3583 2CONSTRUCTION02.18.2011 E103 POWER LEVEL 03 PLAN 3ADDENDUM 102.18.2011 7B.D. RESPONSES04.11.2011 Received By Shelley Bellm at 2:58 pm, Apr 20, 2012 B12-0123 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/26/12 SCALE:1 ELECTRICAL ONE-LINE DIAGRAM NONE ∆ ,WIRING SCHEDULE - COPPER AMPS (2WG)(3WG)(4WG)1Ø, 2 WIRE, GROUND1Ø, 3 WIRE, GROUND OR 3Ø, 3 WIRE, GROUND3Ø, 4 WIRE, GROUND 20 (2#12 & 1#12 G) 3/4"C(3#12 & 1#12 G) 3/4"C(4#12 & 1#12 G) 3/4"C 30 (2#10 & 1#10 G) 3/4"C(3#10 & 1#10 G) 3/4"C(4#10 & 1#10 G) 3/4"C 40 (2#8 & 1#10 G) 3/4"C(3#8 & 1#10 G) 3/4"C(4#8 & 1#10 G) 1"C 50 (2#6 & 1#10 G) 3/4"C(3#6 & 1#10 G) 1"C(4#6 & 1#10 G) 1"C 60 (2#4 & 1#10 G) 1"C(3#4 & 1#10 G) 1"C(4#4 & 1#10 G) 1 1/4"C 70 (2#4 & 1#8 G) 1"C(3#4 & 1#8 G) 1 1/4"C(4#4 & 1#8 G) 1 1/4"C 80 (2#2 & 1#8 G) 1"C(3#2 & 1#8 G) 1 1/4"C(4#2 & 1#8 G) 1 1/2"C 90 (2#2 & 1#8 G) 1"C(3#2 & 1#8 G) 1 1/4"C(4#2 & 1#8 G) 1 1/2"C 100 (2#1 & 1#8 G) 1 1/4"C(3#1 & 1#8 G) 1 1/2"C(4#1 & 1#8 G) 1 1/2"C 110 (2#1 & 1#6 G) 1 1/4"C(3#1 & 1#6 G) 1 1/2"C(4#1 & 1#6 G) 1 1/2"C 125 (2#1 & 1#6 G) 1 1/4"C(3#1 & 1#6 G) 1 1/2"C(4#1 & 1#6 G) 1 1/2"C 150 (2#1/0 & 1#6 G) 1 1/4"C(3#1/0 & 1#6 G) 1 1/2"C(4#1/0 & 1#6 G) 2"C 175 (2#2/0 & 1#6 G) 1 1/2"C(3#2/0 & 1#6 G) 2"C(4#2/0 & 1#6 G) 2"C 200 (2#3/0 & 1#6 G) 1 1/2"C(3#3/0 & 1#6 G) 2"C(4#3/0 & 1#6 G) 2"C 225 (2#4/0 & 1#4 G) 2"C(3#4/0 & 1#4 G) 2"C(4#4/0 & 1#4 G) 2 1/2"C 250 (2-250 KCMIL & 1#4 G) 2"C(3-250 KCMIL & 1#4 G) 2 1/2"C(4-250 KCMIL & 1#4 G) 3"C 300 (2-350 KCMIL & 1#4 G) 2"C(3-350 KCMIL & 1#4 G) 3"C(4-350 KCMIL & 1#4 G) 3"C 380 (2-500 KCMIL & 1#3 G) 2 1/2"C(3-500 KCMIL & 1#3 G) 3"C(4-500 KCMIL & 1#3 G) 3 1/2"C 400 2[(2#3/0 & 1#3 G) 1 1/2"C]2[(3#3/0 & 1#3 G) 2"C]2[(4#3/0 & 1#3 G) 2 1/2"C]450 2[(2#4/0 & 1#2 G) 2"C]2[(3#4/0 & 1#2 G) 2"C]2[(4#4/0 & 1#2 G) 2 1/2"C]500 2[(2-250 KCMIL & 1#2 G) 2"C]2[(3-250 KCMIL & 1#2 G) 2 1/2"C]2[(4-250 KCMIL & 1#2 G) 3"C]600 2[(2-350 KCMIL & 1#1 G) 2 1/2"C]2[(3-350 KC MIL & 1#1 G) 3"C]2[(4-350 KCMIL & 1#1 G) 3"C]700 2[(2-500 KCMIL & 1#1/0 G) 2 1/2"C]2[(3-500 KCMIL & 1#1/0 G) 3"C]2[(4-500 KCMIL & 1#1/0 G) 3 1/2"C]760 2[(2-500 KCMIL & 1#1/0 G) 2 1/2"C]2[(3-500 KCMIL & 1#1/0 G) 3"C]2[(4-500 KCMIL & 1#1/0 G) 3 1/2"C]800 3[(2-300 KCMIL & 1#1/0 G) 2"C]3[(3-300 KCMIL & 1#1/0 G) 2 1/2"C]3[(4-300 KCMIL & 1#1/0 G) 3"C]CONDUCTOR SIZES ARE BASED ON 60°C TERMINATIONS LESS THAN 100A AND 75°C TERMINATIONS GREATER THAN 100A CONDUIT SIZES ARE BASED ON NEC TABLE 4 (RNC) AND TABLE 5 (THHN INSULATION).DISTRIBUTION PANEL:VOLTAGE:277/480V, 3PH, 4W MDP MINIMUM BUS:600 LOCATION:MAIN:MLO MOUNTING:MINIMUM AIC:SURFACE 22,000 PANELS/RISERS MOTORS/EQUIPMENT PANEL SUBTOTAL DEMANDPANEL TOTAL MARK:HP1XFMR SPARESPARELP3ASPACE ELEV-1ELEV-2 SPACE OCPD:125/3 CB225/3 CB60/3 CB60/3 CB RESIDENTIAL 100%0 LIGHTING 030260 30260 125%37825 RECEPTACLES 06192 6192NEC 2206192 LARGEST MOTOR 3324033240 25%8310 MOTORS 045455 3324033240145175 100%145175 EQUIPMENT 19000418184800 65618 100%65618 APPLIANCES 07200 720007200 PANEL TOTAL (KVA):270.3 PANEL TOTAL (A):325 PANEL:HP1 VOLTAGE:277/480V, 3PH, 4W MINIMUM BUS:125 LOCATION:ROOM 311 MAIN:MLO MOUNTING:SURFACE MINIMUM AIC:14,000 NO.LOAD TYPELOAD DESCRIPTION BREAKER BUS BREAKER TYPELOAD DESCRIPTION LOAD NO.AB CPOLE TRIPAB C TRIP POLE AB C 1 2400 E HEAT TRACE (1)1 30 +SPACE2 32100 E HEAT TRACE (1)1 30 +SPACE4 52400E HEAT TRACE (1)1 30 +SPACE6 72100E HEAT TRACE (1)130 +SPACE8 92100E HEAT TRACE (1)130 +SPACE10 111200E HEAT TRACE (1)130 +SPACE12 13 SPARE1 30 +SPACE14 152100 E HEAT TRACE (1)1 30 +SPACE 16 17 3000 E HEAT TRACE (1)1 30 +SPACE 18 191600 E HEAT TRACE (1)1 30 +21SPACE 20 21 900 HEAT TRACE (1)1 30 +SPACE22 23SPACE +SPACE 24 LOAD TYPEPANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMANDFEEDER TOTAL GENERAL NOTES:A.(L) LIGHTING 0 0 125%0 B.(R) RECEPTACLES 0 0 NEC 2200C.(LM) LARGEST MOTOR 0 0 25%0 D.(M) MOTORS (ALL)0 0 100%0 E.(E) EQUIPMENT 19000 19000 100%19000 SPECIFIC NOTES:(A) APPLIANCES 0 0 00 (1)PROVIDE 30MA TRIP GFE CIRCUIT BREAKER PANEL TOTAL (KVA):19.0 (2)(3)PANEL TOTAL (A):23 (4)(5)PANEL:LP1A VOLTAGE:120/208V, 3PH, 4W MINIMUM BUS:400 LOCATION:ELEC ROOM 111 MAIN:400/3 CB MOUNTING:SURFACE MINIMUM AIC:10,000 NO.LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.AB CPOLE TRIPAB C TRIP POLE AB C 1540RRESTROOM RECEPT120 +201EFACP7502 31500EHAND DRYER 116120 +201EFIREPLACE1004 5 1500EHAND DRYER 115120 +201E VENDING (1)12006 71500EHAND DRYER 117120 +201E VENDING (1)12008 9300 EPLUMBING PWR1 20 +20 1EMECH CONTROLS 25010 11 1080 RCORR & WAITING 1091 20 +20 1L1ST FLR LIGHTING 881 12 131080 RWAITING 1091 20 +20 1L1ST FLR LIGHTING 676 14 15600 RMEDIA WALL1 20 +20 1L1ST FLR LIGHTING 77616 17 1080 RLOBBY1 20 +20 1L1ST FLR LIGHTING 79318 191080R 105, 104 1 20 +20 1 EIRRIGATION CONTROLS25020 21500RIT ROOM 129120 +201LEAST STAIR LTG.42722 23500RIT ROOM 105120 +202 L EXTERIOR LIGHTING 62624 25500MADA DOOR OPERATOR120 +L62626 27 360 RELEV PIT120 +201LEXTERIOR LIGHTING108028 29500 RELEV CAB1 20 +20 1LEXTERIOR LIGHTING 112030 31360 R ATM, PARK-N-PAY 1 20 +20 1LEXTERIOR LIGHTING 84632 33900 RSTORAGE AREAS1 20 +20 1LEXTERIOR LIGHTING 35234 35100 MFIRE SMOKE DAMPERS1 20 +20 1LEXTERIOR LIGHTING 65236 37200 MDAMPERS1 20 +20 1LEXTERIOR LIGHTING 150038 39180RELEC ROOM 111 1 20 +20 1 LEXTERIOR LIGHTING67240 41720REXT RECEPT120 +201LEXTERIOR LIGHTING42542 LOAD TYPEPANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMANDFEEDER TOTAL GENERAL NOTES:A.PROVIDE 250 AMP SUB-FEED BREAKER TO LP2 (L) LIGHTING 114528944 20396 125%25495 B.PROVIDE 150 AMP SUB-FEED BREAKER TO LP1B (R) RECEPTACLES 948020780 30260 NEC 22020130C.(LM) LARGEST MOTOR 06192 6192 25%1548 D.(M) MOTORS (ALL)80044488 45288 100%45288 E.(E) EQUIPMENT 855032528 41078 100%41078 SPECIFIC NOTES:(A) APPLIANCES 07200 7200 07200 (1)PROVIDE 5MA TRIP GFCI CIRCUIT BREAKER PANEL TOTAL (KVA):140.7 (2)(3)PANEL TOTAL (A):391 (4)(5)PANEL:LP1B VOLTAGE:120/208V, 3PH, 4W MINIMUM BUS:225 LOCATION:ELECT. RM 111 MAIN:MLO MOUNTING:SURFACE MINIMUM AIC:10,000 NO.LOAD TYPELOAD DESCRIPTION BREAKER BUS BREAKER TYPELOAD DESCRIPTION LOAD NO.AB CPOLE TRIPAB C TRIP POLE AB C 1 750 RSPECIAL EVENT RECEPT.1 20 +153 M FC-1 576 2 3750 RSPECIAL EVENT RECEPT.1 20 +M 576 4 5750RSPECIAL EVENT RECEPT.1 20 +M5766 7750RSPECIAL EVENT RECEPT.120 +303 LM CU-1 20648 9750RSPECIAL EVENT RECEPT.120 +LM206410 11750RSPECIAL EVENT RECEPT.120 +LM206412 13800 LHOLIDAY RECEPT.1 20 +30 1MHRV-1 2300 14 151200 LHOLIDAY RECEPT.1 20 +15 1EB-1 50016 17 250 E UNIT HEATERS, UH-1 1 10 +20 1EINFO CENTER TELECOM 50018 19480 ECABINET UNIT HEATERS1 15 +20 2 E WH-2 100020 21 480 ECABINET UNIT HEATERS1 15 +E 1000 22 231176MP-9 1 20 +20 1 M P-1 1176 24 25720EXT. RECEPTACLES 1 20 +20 1 M P-1 117626 27180RRESTROOM 131120 +201MP-1117628 291600HOLIDAY RECEPT.120 +153 M P-2 44430 31360RHOST SKII STORAGE120 +M44432 33500 EADA DOOR OPERATOR2 20 +M444 34 3585 M P-8 1 10 +153 M P-2 444 36 371176 MP-71 20 +M444 38 391176 MP-41 20 +M444 40 41 85 M P-3 1 10 +SPACE42 LOAD TYPEPANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMANDFEEDER TOTAL GENERAL NOTES:A.FEED THROUGH LUGS (L) LIGHTING 2000500 2500 125%3125 B.(R) RECEPTACLES 50400 5040 NEC 2205040C.(LM) LARGEST MOTOR 61920 6192 25%1548 D.(M) MOTORS (ALL)201100 20110 100%20110 E.(E) EQUIPMENT 47103748 8458 100%8458 SPECIFIC NOTES:(A) APPLIANCES 00 0 00 (1)PANEL TOTAL (KVA):38.3 (2)(3)PANEL TOTAL (A):106 (4)(5)PANEL:LP2 (SECTION 1)VOLTAGE:120/208V, 3PH, 4W MINIMUM BUS:250 LOCATION:IT/ELECT. RM. #210 MAIN:MLO MOUNTING:SURFACE MINIMUM AIC:10,000 NO.LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.AB CPOLE TRIPAB C TRIP POLE AB C 1360RIT 210120 +201R2139002 3360RIT 210120 +201R 213,212 9004 5 360R KITCHEN 209, STORAGE 120 +201R2017206 7540RMECH 211120 +201R2017208 9200 MDAMPERS1 20 +20 1RMECH 202 REC. UH-1 80010 11 100 EPLUMBING CONTROLS1 20 +20 1EMECH CONTROLS 250 12 131500 E HAND DRYER 207 1 20 +20 1L2ND FLR. LIGHTING 793 14 151500 E HAND DRYER 208 1 20 +20 1L2ND FLR. LIGHTING 70716 17 250 MFIRE SMOKE DAMPER1 20 +20 1L2ND FLR. LIGHTING1222 18 19360RCOUNTER 209 1 20 +153 M FC-2 82820 21360RCOUNTER 209120 +M82822 231000ADISPOSAL 209120 +M82824 251200AREFER 209120 +15 3 M FC-3 57626 27 3840 E KILN 209340 +M57628 293840 E +M 57630 313840 E +253 M CU-2 171832 33900 ROFFICE 2051 20 +M 171834 35900 ROFFICE 2041 20 +M 171836 371260 ROFFICE 2031 20 +303 LM CU-3 206438 39900ROFFICE 206 1 20 +LM206440 41SPARE120 +LM206442 LOAD TYPEPANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMANDFEEDER TOTAL GENERAL NOTES:A.PROVIDE FEED-THRU LUGS.(L) LIGHTING 2722 3722 6444 125%8055 B.2-SECTION PANELBOARD. SECTION 2 SPACE ONLY.(R) RECEPTACLES 103405400 15740 NEC 22012870C.(LM) LARGEST MOTOR 61920 6192 25%1548 D.(M) MOTORS (ALL)160088370 24378 100%24378 E.(E) EQUIPMENT 148709200 24070 100%24070 SPECIFIC NOTES:(A) APPLIANCES 22005000 7200 07200 (1)PANEL TOTAL (KVA):78.1 (2)(3)PANEL TOTAL (A):217 (4)(5)PANEL:LP3 VOLTAGE:120/208V, 3PH, 4W MINIMUM BUS:250 LOCATION:STORAGE 311 MAIN:MLO MOUNTING:SURFACE MINIMUM AIC:10,000 NO.LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.AB CPOLE TRIPAB C TRIP POLE AB C 1180RSTORAGE 311120 +201RPANTRY 3095402 3900RWALL 308120 +201RPANTRY 3095404 5 1260RFLOOR 308120 +201EICE MACHING 30915006 7360RIT120 +201MFIRE SMOKE DAMPER2508 9360 RIT1 20 +20 1MECH CONTROLS 10 11 200 MDAMPERS1 20 +20 1LEVENT RM LIGHTING 640 12 131500 E HAND DRYER 304 1 20 +20 1LEVENT RM LIGHTING 640 14 151500 E HAND DRYER 304 1 20 +20 1LEVENT RM LIGHTING 96016 17 1500 E HAND DRYER 303 1 20 +20 1LEVENT RM LIGHTING 65018 191500EHAND DRYER 303 1 20 +20 1 LCATEREING PANTRY LTG29320 21200EPLUMBING120 +201L3RD FLR. LIGHTING53922 23180RBATH 304120 +153 M FC-4 57624 25180RBATH 303120 +M57626 27180RJANITOR 305120 +M57628 29720 RVESTIBULE 3011 20 +153 M CU-4 206430 312500 A ROLL-IN2 30 +M 206432 332500 A +M 206434 351000 EMOTORIZED SHADES1 20 +20 1HRV-2 97236 37500 E AUTO DOOR OPERATOR 1 20 +15 1 P-8, CUH, UH 61538 39SPARE 1 20 +SPARE40 41SPARE +SPARE42 LOAD TYPEPANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMANDFEEDER TOTAL GENERAL NOTES:A.PROVIDE FEED THROUGH LUGS (L) LIGHTING 3722 3722 125%4653 B.(R) RECEPTACLES 5400 5400 NEC 2205400C.(LM) LARGEST MOTOR 0 0 25%0 D.(M) MOTORS (ALL)8370 8370 100%8370 E.(E) EQUIPMENT 9200 9200 100%9200 SPECIFIC NOTES:(A) APPLIANCES 5000 5000 05000 (1)PANEL TOTAL (KVA):32.6 (2)(3)PANEL TOTAL (A):91 (4)(5)PANEL:LP2 (SECTION 2)VOLTAGE:120/208V, 3PH, 4W MINIMUM BUS:250 LOCATION:IT/ELECT. RM. #210 MAIN:MLO MOUNTING:SURFACE MINIMUM AIC:10,000 NO.LOAD TYPELOAD DESCRIPTION BREAKER BUS BREAKER TYPELOAD DESCRIPTION LOAD NO.AB CPOLE TRIPAB C TRIP POLE AB C 43500E AUTO DOOR OPERATOR 201 +SPACE44 454000 RANGE402 +SPACE 46 47 4000 +SPACE 48 49500 ANSIL SYSTEM (1)20 1 +SPACE50 51 +SPACE 52 53500HOOD POWER201 +SPACE54 55935 HOOD FAN 20 1 +SPACE 56 57 SPACE +SPACE 58 59SPACE +SPACE60 61 SPACE +SPACE 62 63SPACE +SPACE64 65 SPACE +SPACE 66 67SPACE +SPACE68 69SPACE +SPACE70 71SPACE +SPACE72 73SPACE +SPACE74 75 SPACE +SPACE 76 77SPACE +SPACE78 79 SPACE +SPACE 80 81 SPACE +SPACE 82 83SPACE +SPACE84 LOAD TYPEPANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMANDFEEDER TOTAL GENERAL NOTES:A.(L) LIGHTING 0 0 125%0 B.(R) RECEPTACLES 0 0 NEC 2200C.(LM) LARGEST MOTOR 0 0 25%0 D.(M) MOTORS (ALL)0 0 100%0 E.(E) EQUIPMENT 500 500 100%500 SPECIFIC NOTES:(A) APPLIANCES 0 0 00 (1)SHUNT TRIP BREAKER PANEL TOTAL (KVA):0.5 (2)(3)PANEL TOTAL (A):1 (4)(5)NOTES:PANEL:LP1C VOLTAGE:120/208V, 3PH, 4W MINIMUM BUS:225 LOCATION:ELECT. RM 111 MAIN:MLO MOUNTING:SURFACE MINIMUM AIC:10,000 NO.LOAD TYPELOAD DESCRIPTION BREAKER BUS BREAKER TYPELOAD DESCRIPTION LOAD NO.AB CPOLE TRIPAB C TRIP POLE AB C 1 1000 EFIREPLACE VENT1 20 +2 3500 LWAITING DISPLAY1 20 +4 5600EMEDIA WALL 1 20 +6 7 600 EMEDIA WALL1 20 +8 91144E FAN COIL/COND2 20 +10 111144E +12 13167 MCF-11 20 +14 15 +16 17 +18 19 +20 21 +22 23 +24 25 +26 27 +28 29 +30 31 +32 33 +34 35 +36 37 +38 39 +40 41 +42 LOAD TYPEPANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMANDFEEDER TOTAL GENERAL NOTES:A.(L) LIGHTING 500 500 125%625 B.(R) RECEPTACLES 0 0 NEC 2200C.(LM) LARGEST MOTOR 0 0 25%0 D.(M) MOTORS (ALL)167 167 100%167 E.(E) EQUIPMENT 4488 4488 100%4488 SPECIFIC NOTES:(A) APPLIANCES 0 0 00 (1)PANEL TOTAL (KVA):5.3 (2)(3)PANEL TOTAL (A):15 (4)(5)FLAG NOTES:∆ ,PANEL:LP3A VOLTAGE:120/208V, 3PH, 4W MINIMUM BUS:100 LOCATION:3RD LEVEL STORAGE MAIN:100/3 CB MOUNTING:RECESSED MINIMUM AIC:10,000 NO.LOAD TYPELOAD DESCRIPTION BREAKER BUS BREAKER TYPELOAD DESCRIPTION LOAD NO.AB CPOLE TRIPAB C TRIP POLE AB C 1 2400 E KITCHEN EQUIP.2 30 +2 32400E +4 5 SPARE230 +6 7 +8 9 SPARE2 20 +10 11 +12 13 +14 15 +16 17 +18 19 +20 LOAD TYPEPANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMANDFEEDER TOTAL GENERAL NOTES:A.(L) LIGHTING 0 0 125%0 B.(R) RECEPTACLES 0 0 NEC 2200C.(LM) LARGEST MOTOR 0 0 25%0 D.(M) MOTORS (ALL)0 0 100%0 E.(E) EQUIPMENT 4800 4800 100%4800 SPECIFIC NOTES:(A) APPLIANCES 0 0 00 (1)PANEL TOTAL (KVA):4.8 (2)(3)PANEL TOTAL (A):13 (4)(5)COPYRIGHT 2010 B ANZE G EAUDIN (970)949-6108 (530)550-7334 (303) 278-3820 (970) 221-5691 (505) 323-9070 Vail:Lake Tahoe:Denver:Fort Collins:Albuqu erque:www.bgce.com ISS. #ARCHITECT'S PROJECT NO. :KEY PLAN DESCRIPTION DATE 21064.04 OWNER 4240 ARCHITECTURE INC 3003 LARIMER STREET DENVER, CO 80205 ARCHITECT t: 303.292.3388 copyright 2010 f: 303.292.3113 VAIL, COLORADO TOWN OF VAIL DEPARTMENT OF PUBLIC WORKS 1309 ELKHORN DRIVE VAIL, CO 81632 ALPINE ENGINEERING INC.34510 U.S. 6 UNIT A9 EDWARDS, CO 81632 CIVIL ENGINEER PEAK LAND CONSULTING , INC.1000 LIONSRIDGE LOOP VAIL, CO 81675 SURVEYOR MARTIN/MARTIN, INC.12499 WEST COLFAX AVE.LAKEWOOD, CO 80215 STRUCTURAL ENGINEER BEAUDIN GANZE CONSULTING ENGINEERS, INC.222 CHAPEL PLACE UNIT AC-201 AVON, CO 81620 MEP ENGINEER t: 970.479.2158 f:970-926-3390 t: 970.926.3373 t: 970.476.8644 t: 303.431.6100 t: 970.949.6108 LIONSHEAD TRANSIT WELCOME CENTER MARY HART DESIGN POST OFFICE BOX 8528 BRECKENRIDGE, CO 80424 LANDSCAPE ARCHITECT t: 970.389.3583 2CONSTRUCTION02.18.2011 E400 ELECTRICAL ONE-LINE DIAGRAM 3ADDENDUM 102.18.2011 4ADDENDUM 203.02.2011 7B.D. RESPONSES04.11.2011 CCD #2311.16.2011 CCD #2402.21.12 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) MH 4/26/12