Loading...
HomeMy WebLinkAboutB09-0288NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES r' TOM O VVAII, � Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 ADD /ALT COMM BUILD PERMT Permit #: B09 -0288 Project #: RM9- a s3� Job Address: 12 VAIL RD VAIL Location......: SUITES 800 -1000, GATEWAY Parcel No....: 210108264029 OWNER GGG LLC 10/06/2009 PO BOX 5963 VAIL CO 81658 APPLICANT HIGH COUNTRY ENTERPRISES 74, 10/06/2009 Phone: 970 - 827 -4140 472 MAIN STREET / P.O. BOX 383 MINTURN CO 81645 License: 685 -B CONTRACTOR HIGH COUNTRY ENTERPRISES 74,10/06/2009 Phone: 970 - 827 -4140 472 MAIN STREET / P.O. BOX 383 MINTURN CO 81645 License: 685 -B Description: TENANT IMPROVEMENT: REMOVE WALLS, INSTALL WOOD FLOORING Occupancy: B Type Construction:IIA Status .. : ISSUED Applied. . 10/06/2009 Issued ...: 10/22/2009 Expires, ..: 04/20/2010 Valuation: $3,200.00 Total Sq Ft Added: 0 FEE SUMMARY Building Permit Fee ------ > $97.25 Will Cal Fee --------------------- > $4.00 Total Calculated Fees ------------- > $164.46 Plan Check--------------- - - - - -> $63.21 Use Tax Fee --------------------- > $0.00 Additional Fees------------------ - - - - -> $0.00 Add'I Plan Check Hours- $0.00 Restuarant Plan Review - - - - -> $0.00 TOTAL PERMIT FEES--------- - - - - -> $164.46 Investigation------------ - - - - -> $0.00 Recreation Fee------------ - - - - -> $0.00 Payments ------------------------------- > $164.46 Total Calculated Fees--- - - - - -> $164.46 BALANCE DUE ------------------------ > $0.00 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM. 0 Signature of Owner r Contractor e C toS Print Name bid_alt_construction_pe rm it_041908 ly ��2 /vim Date TOWN OF VAIL, COLORADO Statement Statement Number: R090001520 Amount: $164.46 10/22/200901:45 PM Payment Method: Check Init: JLE Notation: 1197 HIGH COUNTRY ENT ----------------------------------------------------------------------------- Permit No: B09 -0288 Type: ADD /ALT COMM BUILD PERMT Parcel No: 2101 - 082 - 6402 -9 Site Address: 12 VAIL RD VAIL Location: SUITES 800 -1000, GATEWAY This Payment: * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code ----------------- BP 00100003111100 PF 00100003112300 WC 00100003112800 Total Fees: $164.46 $164.46 Total ALL Pmts: $164.46 Balance: $0.00 Description Current Pmts - -- ------------------------ - - - - -- ------ - - - - -- BUILDING PERMIT FEES 97.25 PLAN CHECK FEES 63.21 WILL CALL INSPECTION FEE 4.00 Town of ve�i F-,01 -c2tr K OFFICE COPY Vail Fire Department Asbestos Testing & Abatement Requirements Asbestos testing and abatement protects workers, homeowners, neighbors and emergency services responders from ex- posure to harmful asbestos. The Town of Vail asbestos abatement program is in addition to the State of Colorado's regu- lations. It is your responsibility to be in compliance with the State. Please contact the State directly for their requirements at the contact info listed below. When is asbestos testing required? ANY building projects disturbing more than these threshold levels of building materials require asbestos testing: One- and Two - Family Dwellings: 30 square feet All Others: 1.66'square feet 3z Asbestos testing results must be provided with your application for a building permit. Tests which identify POSITIVE results at more than 1% require abatement by a State - certified and Vail- registered abate- ment contractor. An asbestos abatement permit must be approved, and the clearance letter must be submitted to the Town of Vail before the building permit will be issued Project Checklist My project falls into the category checked below: Will not disturb more than the threshold limits identified above. Tested negative, or at 1% or below (2 copies of test results included) Tested positive at more than 1 %, requires abatement (2 copies of test results included) Tips & Facts: • Even recent construction projects may include asbestos - containing materials, so buildings of qn I age require testing. • The "1989 Ban" on asbestos - containing materials is commonly misunderstood. "In fact, in 1991 the U.S. Fifth Circuit Court of Appeals vacated much of the so- called "Asbestos Ban and Phaseout" rule and remanded it to the EPA. Thus, much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce of many asbestos - containing product categories was set aside and did not take effect." - CDPHE Asbestos test results and abatement permit applications should be submitted to: Town of Vail, Community Development, 75 S Frontage Rd, Vail, CO, 81657. Town of Vail Contact: David Rhoades, Fire Inspector Vail Fire Department 75 S Frontage Rd drhoades@vailgov.com 970 - 477 -3454 www.vailgov.com State of Colorado Contact: Colorado Department of Public Health and Environment Asbestos Compliance Assistance Group 303 - 692 -3158 asbestos@state.co.us www.cdphe.state.co.us 8- Jun -09 Town of Vail OFFICE COPY Asbestos Inspection and Sampling Report 12 Vail Road in Vail, CO 81657 Presented to: Mr. Jim Gonzales High Country Enterprises 164 Railroad Ave. Minturn, CO 81645 Performed by. Mr. Brandon Sinkbeil DS Consulting, Inc. P.O. Box 6864 Avon, CO 81620 Project Details: DSC Project #: 1578 Conducted: October 2, 2009 DS Consulting, Inc. Unmatched Credentials. Superior Results. EC���� D 5 2009 TOWN O'F YAIL EXECUTIVE SUMMARY On October 2, 2009, Mr. Brandon Sinkbeil of DS Consulting, Inc. (DSC) performed a limited inspection and asbestos sampling at 12 Vail Road in Vail, Colorado, in order to identify potentially hazardous friable and non - friable asbestos - containing materials (ACM) within a portion of the above - referenced, office building scheduled for a remodel. Mr. Sinkbeil performed asbestos bulk - sampling of drywall (surfacing material) in a total of three (3) locations within the office. All three (3) bulk - samples were analyzed by Aerobiology & Associates, Inc. (NVLAP #200860 -0) with all three (3) laboratory results being non - detect for ACM (see Appendix B for laboratory results). 2 PROJECT OVERVIEW I. Introduction A limited inspection and bulk - sampling for ACM was conducted at 12 Vail Road in Vail, Colorado by Mr. Sinkbeil on October 2, 2009 at the request of Mr. Jim Gonzales with High Country Enterprises. Mr. Sinkbeil is a Colorado State Certified Building Inspector and has EPA Accreditation #13442 (see Appendix A for certificate). The purpose of the inspection was to identify, sample, and assess potentially hazardous friable and non - friable ACM from within the above - referenced office building scheduled for a remodel. II. Structural Design The structure is a multi - story, commercial office building. III. Sampling and Analytical Procedures The inspection, assessment and sampling were conducted by an EPA and AHERA accredited Building Inspector qualified by experience, education and training in the recognition of potential ACM and approved bulk - sampling techniques. The asbestos bulk - sampling was conducted on suspect ACM with a limited number of bulk - samples being collected within the office building. The inspection, assessment and sampling were performed in accordance with Environmental Protection Agency / AHERA recommended procedures. These procedures call for the visual inspection of the area of concern and the collection and analysis of representative bulk - samples of suspect material. Some minor destructive sampling was conducted. Walls, columns and perimeter pipe chases were not broken into in order to locate and quantify suspect ACM. It should be noted that additional ACM might be located in these and other inaccessible areas. Random bulk - samples, representative of the suspect asbestos - containing building materials (ACBM) of each homogeneous area (HA), were collected according to the guidelines published as Environmental Protection Agency (EPA) Final Rule: Title II of the Toxic Substances Control Act (TSCA), 15 USC, Sections 2641 through 2654 and in compliance with 40 CFR, Part 763. Representative sampling is based on the following criteria: 1. The distribution of the suspect material throughout the HA. 2. The suspect material's physical characteristics and application. 3. Random sampling patterns determined for each HA. Suspect materials sampled and analyzed should be considered to be representative of materials in each HA if: 1. They exhibit similar physical characteristics; and 2. The application of the sampled material can be correlated to the application of un- sampled material. 3 Bulk- samples collected were analyzed utilizing the EPA's Method for the Determination of Asbestos in Bulk Building Materials (EPA 600/R/116, July, 1993) and the McCrone Research Institute's The Asbestos Particle Atlas as methods references. Analysis of the bulk - samples was performed on the "date reported," as listed in the bulk - sample analysis report. IV. Notes on Report Format Suspect materials alike in appearance and application were sampled as HAs. Suspect materials were divided into three classifications: 1. Surfacing material: sprayed or troweled onto structural building member. 2. Thermal System Insulation (TSI): any type of pipe, boiler, tank, or duct insulation. 3. Miscellaneous: other suspect materials, floor tile, sheet vinyl /linoleum, ceiling tiles, insulation, and finishing materials. Condition assessments were performed by the accredited inspector at the time of inspection. Condition assessments are listed in the following section. Ratings of "good," "damaged," and "significantly damaged" are meant to indicate the overall condition of the material. A material in "good" condition has no visible damage or deterioration, or showing only very limited damage or deterioration. A material in "damaged" condition has the following characteristics: The surface is crumbling, blistered, water - stained, gouged, marred or otherwise abraded over less than one -tenth of the surface if the damage is evenly distributed (one - quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. A material in "significantly damaged" condition has one or more of the following characteristics: ■ The surface is crumbling or blistered over at least one -tenth of the surface if the damage is evenly distributed (one - quarter if the damage is localized). ■ One -tenth (one - quarter, if localized) of the material is hanging from the surface, deteriorated, or showing adhesive failure. ■ Water stains, gouges, or mars are over at least one -tenth of the surface if the damage is evenly distributed (one - quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. 4 Response- action recommendations for asbestos containing HAs are listed in the section VII. Recommendations may be for more than one HA, if materials are alike. Recommendations are either "general" or "immediate." An immediate recommendation indicates an imminent hazard exists and should be addressed as soon as possible. A general recommendation indicates no imminent hazard exists and no further abatement activities are required for removal of the material. V. Inspector Comments No ACM was identified during the bulk - sampling conducted at 12 Vail Road in Vail, Colorado. A total of three (3) bulk - samples were collected from drywall in the above - referenced office building. All three (3) bulk - samples tested non - detect for asbestos. VI. Homogeneous Area Descriptions The following section contains sampled HA descriptions and sample locations. Percent - asbestos content for each sample indicated can vary depending on sample locations, homogeneity of the materials, and type of application. The following samples were collected from the building at 12 Vail Road in Vail, Colorado, on October 2, 2009. The quantities are approximations and are subject to field verification: Homogeneous Area #01s Sample #; DW -02 Sample #: DW -01 Sample Description: Drywall Sample Description: Drywall Sample Location: Office Wall Sample Location: Office Wall Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity: +/ -100 ft2 Material Quantity. +/ -100 ft2 Material Condition: Good Material Condition: Good Physical Description (layers): Brown /Cream paint; Yellowish white compound; White tape; White joint compound Physical Description (layers): Yellow resinous plaster; White tape; White joint compound; Pink tan drywall w white paint Asbestos Content (layers): Non - detect; Non - detect; Non - detect; Non - detect Asbestos Content (layers): Non - detect; Non - detect; Non- detect; Non - detect Recommendations: GENERAL - See Section VII Recommendations: GENERAL - See Section VII 5 Sample #: DW -03 Sample Description: Drywall Sample Location: Office Wall Material Classification: Surfacing Material Material Quantity. +/ -100 ft2 Material Condition: Good Physical Description (layers): Brown paint; White tape; White joint compound; Pink tan drywall Asbestos Content (layers): Non - detect; Non - detect; Non - detect; Non - detect Recommendations: GENERAL - See Section VII VII. Recommendations GENERAL: The laboratory results of the potential ACM sampled at 12 Vail Road in Vail, Colorado, indicate that all three (3) bulk- samples were reported as non - detect for asbestos. Therefore, no professional abatement activities are recommended to remove the above - referenced material. R APPENDIX A CERTIFICATION STATE OF COLORADO s certifies that Brandon Sinkbeii Certillcntlon No: I 42 has met the requirentents of 25-7 -507, C.R.S. and Air Qurtiiiy Control a Convnission Regulation No, 8, tart B, and is hereby calified by the state of Colorado in the following discipline: Building Inspector* ` ° : lssaed: N W2009 7 I ASBESTOS } CERTIFICATION* Coles Department of Public Health and F.nvirorttncttt Air Pollution GtanW Division s certifies that Brandon Sinkbeii Certillcntlon No: I 42 has met the requirentents of 25-7 -507, C.R.S. and Air Qurtiiiy Control a Convnission Regulation No, 8, tart B, and is hereby calified by the state of Colorado in the following discipline: Building Inspector* ` ° : lssaed: N W2009 7 I > O O ".,at N K d u ao M C w 7 p m O U En U M o a v a3i m y ed C Q O w LA 4 10 GT Z //� ` G 1--/J s 0 pp is 0 J� O\ O\ 0\ D O Cl O O r N N N N sY 0000vY 0 0 0 0 0 � abi a�i abi � A U ¢ O AAAA O O b � o 'L� Z J �-ccx Y Y cc •� O E x U o N 0 U c Goc zr- ai R z a � N o y z°c° a` � c � a U U d U a d h C m A 0 0 M F N vi a+ C.O� y•ci r.O� O'U >iHaOCQ I�A II II II II II II II II II a, II dU >C7�Fa0agOA 0 Y 3 6u- U.S 0 IWr.3zz.rn� a „ II II II II II �, ,a��7�oxU II II yo o�.ob'oF p •�"�"'U O y N d¢¢UUE� - H s Y y �y O d l i T 14, O � o 0 m at°. as U Gq U C7 0 U o �o M O O z • 0 ow U ON ��U FU °`U FU rnu z U w nU > > ' > > > O bq b0 dQ dq bA DO g bq bq bq p z z z z z z z z z z o l� w kn O O O O .fir N V1 W O a cN w °� N .� V b a QI N ¢ as U A ¢ rya U A w ¢ z h en op i!1 o w) 0 Vr) 0 in 0 In 0 0 Vl 0 Vl 0 Vl o c [a N En C U C Q N M A A N vi a+ C.O� y•ci r.O� O'U >iHaOCQ I�A II II II II II II II II II a, II dU >C7�Fa0agOA 0 Y 3 6u- U.S 0 IWr.3zz.rn� a „ II II II II II �, ,a��7�oxU II II yo o�.ob'oF p •�"�"'U O y N d¢¢UUE� - H s Y y �y O d l i T 14, O � o 0 m at°. d oov at N 7 N Ci L W X Q O M O V O O O O O N U M bo N N N 7 OOOOVi 0m 0 0 0 0 0 a m C7, a � Up;dfs+��� o rn A A A ti O � e M O� a 0 �o a w 'C v id o G W O M W >•, � lr� o Q d o t.. p 6� � � o �U o z A s w a > > > Av •y C a � a m ao 6 z ^A j z I^ V mac✓ 7 Y z � OC R : +Q+ W y 61 .o M W d W 6 e� z •o d Pia ° trb UrAUdU [= N •� v, U »�Fa�.,Ow II A II II II II II II II II II p., II O'U >C7�Fa.0ac10A H d o o �•�. o ��Fx vi N d y ..+:r Q g o g U���000.q II wv�3Z'ZrLS II II II II II II k w H¢ °x U wCA zzw¢ d c�YU 0 0 II II II II � ddQuu F- 0 i r 10 IOU 1 a �y s .a 1 O \ p 0 N a � o O � e z O ° W d•-�o U F U �U z > > > Av z z z .o d o � z z z o 0 r .� b a c °O -U ra F � 0 A A.s 3 U b .a a s zM M by O O A O ctl as b d y M U A N •� v, U »�Fa�.,Ow II A II II II II II II II II II p., II O'U >C7�Fa.0ac10A H d o o �•�. o ��Fx vi N d y ..+:r Q g o g U���000.q II wv�3Z'ZrLS II II II II II II k w H¢ °x U wCA zzw¢ d c�YU 0 0 II II II II � ddQuu F- 0 i r 10 IOU 1 a �y s .a 1 O \ p 0 N a 04 -24 -2012 Inspection Request Reporting Page 8 4:39 Dm Vail. CO - City Of Requested Inspect Date: Wednesday, April 25, 2012 Inspection Area: JRM Site Address: 12 VAIL RD VAIL SUITES 800 -1000, GATEWAY A/P /D Information Activity: B09 -0288 Type: A -COMM Sub Type: ACOM Status: ISSUED Const Type: Occupancy: Use: IIA Insp Area: JRM Owner: GGG LLC Contractor: HIGH COUNTRY ENTERPRISES 74, INC. Phone: 970 - 827 -4140 Description: TENANT IMPROVEMENT: REMOVE WALLS, INSTALL WOOD FLOORING Requested Inspectionts Item: 90 BLDG -Final Requested Time: 11:00 AM Requestor: Phone: Comments: FOLLOW UP Assigned To: SGREM Entered By: JMONDRAGON K Action: Time Exp: Comment: VVALk1WhtMUVLU PER PLANS. ALL-OTFiER -WORK WAS EXISTING, NON - COMFORMING INCL ING STAIRS 1) OBTAIN PLUMBING PERMIT FOR NEW SINK IN SOUTH KITCHEN AREA. ' L 'pp�) Inspection History Item: 30 BLDG - Framing Item: 50 BLDG - Insulation Item: 60 BLDG - Sheetrock Nail Item: 70 BLDG -Misc. Item: 90 BLDG -Final 11/09/09 Inspector: cg Action: CR CORRECTION REQUIRED Comment: WALLS REMOVED PER PLANS. ALL OTHER WORK WAS EXISTING, NON - COMFORMING OBTAIN PLUMBING PERMIT FOR NEW SINK IN SOUTH KITCHEN AREA. REPT131 Run Id: 14386