Loading...
HomeMy WebLinkAboutB12-0107 plansfown of Vail REVIEWED FOR COMPI I,A N Date:. — By: r Code: - DECK CEILING NOTE: AN ENTIRE DRYWALL CEILING TO BE REMOVED. 0 JOIST SPACES TO BE FILLED WITH BLOWN -IN INSULATION. NEW 5/8" TYPE "X" DRYWALL TO BE HUNG FROM HAT CHANNELS ON ISOLATION CLIPS. ENTIRE CEILING TO BE APPROXIMATELY 1 1/2" LOWER THAN €' E PREVIOUS CEILING.""" C � �• u�c o o � w J Q 0 DINING ROOM REMOVE WALLS AND POCKET DOOR REMOVE CEILING "BULKHEAD" NEW RESTORE TO HEIGHT OF COUNTER TOP OVERALL CEILING JR EMOVE LIVING ROOM OUNTER TOP REMOVE BOXED -OUT AREA i I r REMOVE CLOSET o 0 WALLS AND DOOR �I I�I) REMOVE HALF WALL, REPLACE I WITH IRON RAILINGS U U — REMOVE WALLS, u KITCHEN — — — — ADD NEW WALL, NEW LOCATION FOR REF. 0 NEW IRON RAILING / j I 1 00 �j 1 00 ENTRY DIN DN � (V i N m 5'- 6" 1 5'- 1 3/4" NEW WALLS TO - CREATE COAT CLOSET UNIT 1A GARAGE ICI 51% ­(NRt �OSlj.A So UNIT 2A GARAGE Note The architect is assuming that there are no structural implications to the changes as shown. The General Contractor must notify the architect if any posts, beams, headers, or any other structural items are effected by the work proposed. Level 1 1 /4" = 1' -0" � 5 Py v . Cool- —N90 �% Ear PoNK ! WVPV< wt'tt{ NO REMODEL WO I PROPOSED Hpj LEVEL. III 11 L) AN 0 CD €' NO REMODEL WO I PROPOSED Hpj LEVEL. III 11 L) TOM11 OF V1411- M 7 0 !_�� 0 o N CO V 0 0 CD E C � �• U N o o � w J Q 0 Q IA V W ,6 0 d ■ p rn r w S v c m p o E L r ut O � ry M a I O U) W — Z Q ti LU O �� O u m _0 o � Co Wa0 o 0 of U H E x (0 � L) U > O L O U I i m TOM11 OF V1411- M 7 0 !_�� 0 o N CO V WOOD JOISTS, GYPSUM WALLBOARD, RESILIENT CHANNELS 2 psf One layer 1 /2" type X gypsum wallboard or gypsum veneer base applied at right angles to UL R3501 -29, 3- 23 -64, resilient furring channels 24" o.c. with 1" Type S drywall screws 12" o.c. Gypsum board UL Design L515 end joints located midway between continuous channels and attached to additional NGC 4010, 3 -21 -66 pieces of channel 54" long with screws 12" o.c. Resilient furring channels applied at right (Rev. 12- 23 -70) angles to 2 x 10 wood joists 16" o.c. with 1 1 /4" Type W drywall screws. Wood joists 38 (63 C & P) supporting 1" nominal T & G wood subfloor and 1" nominal wood finish floor or 79 /32" NGC 5016,3-17-66 p ywood finished floor with long edges T & G and 15 /32" interior plywood with exterior glue ------- - - - - -- subfloor perpendicular to joists with joints staggered. Approx. Ceiling Weight: 3 psf Fire Test: UL R1319 -65, 11- 16 -64, UL Design L514 Sound Test: CK 6512 -6, 7, 4 -15 -65 1!C & Test: 39 (67 C & P) CK 6512 -6, 4 -15 -65 WOOD JOISTS, GYPSUM WALLBOARD, RESILIENT CHANNELS One layer 1 /2" type X gypsum wallboard or gypsum veneer base applied at right angles to resilient furring channels 24" o.c. with 1" Type S drywall screws 11" o.c. Gypsum board end joints located midway between continuous channels and attached to additional pieces of channel 54" long with screws 12" o.c. Resilient furring channels applied at right angles to 2 x 10 wood joists 16" o.c. with 1 Type W drywall screws or 6d common nails. Wood joists supporting 1" nominal T & G wood subfloor and 1" nominal wood finish floor, or 5 /e" plywood finished floor with long edges T & G and 1 /2" interior plywood with — exterior glue subfloor perpendicular to joists with joints staggered. Approx. Ceiling Weight: 2 psf Fire Test: UL R3543 -8, 7 -8 -68, UL Design L517 Sound Test: See FC 5240 (CK 6512 -6, -7, 4- 15 -65) WOOD JOISTS, GYPSUM WALLBOARD, RESILIENT CHANNELS f rrrt ) guUNL? One layer 1 /2" type X gypsum wallboard or gypsum veneer base applied at right angles to resilient furring channels 24" o.c. with 1" Type S drywall screws 12" o.c. Gypsum board end joints located midway between continuous channels and attached to additional pieces of channel 60" long with screws 12" o.c. Resilient furring channels applied at right angles to 2 x 10 wood joists 16" o.c. with 6d coated nails, 2" long, 0.113" shank, 17 /64" heads. Wood joists supporting 1 " nominal wood subfloor and 1 " nominal wood finish floor, or 19 /32" plywood finished floor with long edges T & G and 15 /32" interior plywood with exterior glue subfloor perpendicular to joists with joints staggered. Approx. Ceiling Weight: 2 psf Fire Test: UL R2717 -29, 1- 24 -64, UL Design L502; ULC Design M501 Sound Test: RAL TL64 -155, 2 -7 -64 IIC & Test: 39 (67 C & P) See FC 5240 (CK 6512 -6, 4- 15 -65) This Space Left Blank 108 uontaci me manufacturer Tor more detailed information on proprietary products. GA- 600 -2000 WOOD JOISTS, GYPSUM WALLBOARD, RESILIENT CHANNELS One layer 1 /2" type X gypsum wallboard or gypsum veneer base applied at right angles to resilient furring channels 24" o.c. with 1" Type S drywall screws 12" o.c. Gypsum board end joints located midway between continuous channels and attached to additional pieces of channels 53" long with screws 12" o.c. Resilient furring channels applied at right angles to 2 x 10 wood joists 16" o.c. with twoYld coated nails, 1 1 /2" long, 0.080" shank, and 7 /32" heads, per joist. Wood joists supporting 1 " nominal T & G wood subfloor and 1" nominal wood finish floor, or 5 /e" plyworwd finished floor with long edges T'& G and ; 15 /32" interior plywood with exterior glue subfloor perpendicular to joists with joints staggered. WOOD JOISTS, GYPSUM WALLBOARD 1 Approx. Ceiling Weight: 2 psf Fire Test: UL R3501 -29, 3- 23 -64, UL Design L515 Sound Test: NGC 4010, 3 -21 -66 (Rev. 12- 23 -70) IIC & Test: 38 (63 C & P) NGC 5016,3-17-66 One layer 5 /e" type X gypsum wallboard or gypsum veneer base applied at right angles to rigid furring channels 24" o.c. with 1' Type S drywall screws 12" o.c. Gypsum board end joints located midway between continuous channels and attached to additional pieces of channel 60" long with screws 12" o.c. Rigid furring channels applied at right angles to 4 x 10 or double 2 x 10 wood joists 48" o.c. with two 1 Type S drywall screws at each joist. Wood joists supporting 1 " T & G plywood floor. Approx. Ceiling WOOD JOISTS, GYPSUM WALLBOARD Base layer 5 /e" type X gypsum wallboard applied at right angles to 2 x 10 wood joists 24" o.c. with 1 Type W or S drywall screws 24" o.c. Face layer 5 /a" type X gypsum wallboard or gypsum veneer base applied at right angles to joists with 1 Type S drywall screws 12" o.c. at joints and intermediate joists and 1 Type G drywall screws 12" o.c. placed 2" back on either side of end joints. Joints offset 24" from base layer joints. Wood joists supporting 1 /2" plywood with exterior glue applied at right angles to joists with 8d nails. Ceiling provides one hour fire resistance protection for wood framing, including trusses. Weight: 2.5 psf Fire Test: UL R1319 -47, 5 -8 -63, UL Design L508 Sound Test: Estimated Approx. Ceiling Weight: 5 psf Fire Test: FM FC 172, 2 -25 -72 Sound Test: Estimated {_fJS /f t)i V aii f REVIEWED FOR CODE f"30 OMPLIA Date, This Space Left Blank y: � Codes d! GA- 600 -2000 t Contact the manufacturer for more detailed information on proprietary products. 109