Loading...
HomeMy WebLinkAboutB12-0157 Asbestos ReportA & D Asbestos Testing and Consulting John R. Peterman P.O. Box 1230 Cell 970- 270 -3689 To: George Shaeffer Construction P.O. Box 373 Vail, Co. 81658 Clifton, CO. 81520 -1230 Home Phone 970 -464 -5265 May 8, 2012 Attn: Inge Hill RE: Asbestos inspection and testing at the Residence located at 1195 Hornsdver Cr. Vail, CO. Q1Y- Description CD-9 3 - Bulk Samples (24 Hr.tum around) L 555.00 ea $165.00 1/2 - Day5 Labor $225.00 TOTAL AMOUNT DUE THIS INVOICE $390.00 1 A & D Asbestos Testing and Consulting John R. Peterman P.O. Box 1230 Clifton, CO. 81520 -1230 Cell 970 -270 -3689 Home Phone 9704-64 -5265 INSPECTION REPORT PREPARED FOR: George Shaeffer Construction P.O. Box 373 Vail, Co. 81658 LOCATION: The Residence 1195 Hornsilver Cr. Vail, Co. REPORT PREPARED BY: John R. Peterman Inspector Manager COLORADO Certificate No. 6601 COLORADO Registration #ACF-16522 UTAH Certificate No. 1236 2 A & D Asbestos Testing and Consulting John R. Peterman Asbestos Testing, Project Deign, and Consulting INTRODUCTION: On May 4, 2012 an inspection/survey was conducted and 3 bulk samples were collected from: The Residence 1195 Hornsilver Cr. Vail, Co. The purpose of the inspection/survey was to locate and sample suspected Asbestos containing matcdals that might be present in the garage that is planned for renovation. The inspection was made, and the samples were collected by John R. Peterman, an A.H.E.R.A. and State of Colorado and Utah Certified Asbestos Inspector. Great care was taken during the inspection and sampling to be as accurate as possible. It should be noted that minimal damage was done to the existing building structures during the inspection so there is no documentation for unseen conditions or stored items. All s amp les were analyzed by DC M Science Lab in W heatridge, CO. This laboratory is deemed "Proficient" in the E.P.A.Quality Assurance (QA) program for the determination of asbestos in bulk materials, and is accredited by the American Hygiene Association (AHA). SAMPLING PROTOCOL: COL: A random sampling scheme was used to sample the suspect materials that were discovered. If during any future demolition or renovation work, suspect material is discovered that hasn't been sampled and would be disturbed, work should be halted until the material has been tested. 4 A & D Asbestos Testing and Consulting John R. Peterman i Asbestos Tasting, Project Design, and Consulting The Residence 1195 Homsilver Cr. Vail, Co. BUILDING DESCRIPTION: The garage is planned for interior renovation. The interior walls are covered in sheetrock with a light texture.The ceilings are covered in sheetrock like the walls. The floors are exposed concrete. CONCLUSIONS & RECOMMENDATIONS: Laboratory analysis of the composite sheetrock samples indicates that no Asbestos was detected. 5 Date: 5/8/2012 Loceflon: ;,Co. SAMPLE LOCATIONS jSAMPLE NUMBER AREA SAMPLE REMOVED FROM DESCRIPTION. 11;9:t 003 j: Gargip Wall -NO ' � L Date: Location' Co. 5/8/2012; 'SAMPLE RESULTS r % -",-fN!L 14BIM DESCRIPTION ASBESTOS TYPE 11 t#rB I C4ffqmWW Sheatock W) T re NAD - -000 - , Com osits Sheetp(* W/ Texture_.__ NAD 0.00 1195-8 003 0.00 ___�Coff.iposftSheetDckWl &�rq NAD I _....._._ - - -+ I KEY: No Asbestos Detected --' - SUR I 195-B 003 Date: 518/201 Locadw: I !Residence 1195 Hornsilver Cr. Vail, Co. 'SUSPECT MATERIAL CONDITION SAMPLE NU BER: TYPE OF SUSPECT MATERIAL. � OVERALL CONDITION I DAMAGED _%___TYPE OF DAMAGE 140 0 N/A NO 0 WA Jl NO NIA . -'-,--'--_-' M Location ;Co. 'Sample Numbe Influence Potential i Plenum 11 95-B 001 YES HIGH LOW L OW NO -jf YES HIGH LOW LOW NO_ LOW LOW NO 66S HiGH NO M -2R 1195 -8.002 S-4-12 A WHITE FARTT 1.0% ND 0.0 100.0 a WKnE AND GREY DRYWALL WUD 40% ND 0.0 1000 C TAN FIBROUS }•C•I� ND 100.0 co D WHRE DRYWALL 1111.0% ND — 2 0 rx21 W .m) •vwta. LWT r WHAT aLOCNL EV OW)(=)+►H1f0 pp t{W i AF -3R 1195 -B.003 5 -4-12 A WHITE PAINT 10% BULK ASBESTOS TEST REPORT 0 0 .? ?R{ 4.0% ND 100.0 00 PAGE I OF 2 6. Do/. NO 0.0 1000 CLIENT. 190% No ANALYSIS DATfi 5.1 -12 NO A&D ASBESTOS TESTING AND CONSULTR40 REPOKTTNG DATE. 5 -11.12 0) - INSEPARABLE LAYERS ND- NONE DETECTED P.O. Box 1130 RECEIPT DATE. 3.7.12 TiiESAMPLES WERE RECEIVED IN ACC EPTABLE CDNDJTION. THIS TEST REPORT RELATES ONLY TO THE ITEMS =ED. THUS REPORT MAY NOT BE REPRODUCED EXCEPT IN FULL WTIfiOUT Tilt WRJTTEN APPROVAL OF THE LABORATORY Ci.IFTON, CO 81520.1230 CUE�TT JOB NO. MlOF14CE PROJECT TITU-- 1195 HORMILVER CK. - VAIL. CO DCMSI. PROJECT ADAT729 PERCENTAGE COMPOSITION BY VISUAL ESTIMATE TOTAL DCMSL CLIENT TOTAL PERC-ENTAGE SAMPLE SAMPLE SAMME PERCENT ASSESfCG ASBESTOS OTHER FIBROUS NON- FIBROUS IDFWnFIED NUMStR NUMBER DATE DESCRIPTION OF SAMPLE TYPE RANGE % M SAMPLE CONSTrr"UFNTS CONSITTUENJB MATERIALS • 1R 1 193.8 001 5 -4-12 A TAN PAINT 2.0% ND 0:0 100 0 100.0 B TAN FIBROUS SOX NO 1000 (k0 1010.0 C. WfUTE DRYWALL MUD 7W. ND 00 1000 1000 D. WRITE DRYWALL $60% ND 20 98.0 100.0 -2R 1195 -8.002 S-4-12 A WHITE FARTT 1.0% ND 0.0 100.0 a WKnE AND GREY DRYWALL WUD 40% ND 0.0 1000 C TAN FIBROUS 7.0% ND 100.0 co D WHRE DRYWALL 1111.0% ND — 2 0 98,0 ND -3R 1195 -B.003 5 -4-12 A WHITE PAINT 10% NO 0 0 100.0 B. TAN FIBROUS 4.0% ND 100.0 00 C. WHITE DRYWALL MUD 6. Do/. NO 0.0 1000 D. WHITE DRYWALL 190% No 1.0 9110 NO FOR CALCULATION PURPC)SES, TRACE (TR) IS ASSUI) M TO BE 0.5% 0) - INSEPARABLE LAYERS ND- NONE DETECTED TiiESAMPLES WERE RECEIVED IN ACC EPTABLE CDNDJTION. THIS TEST REPORT RELATES ONLY TO THE ITEMS =ED. THUS REPORT MAY NOT BE REPRODUCED EXCEPT IN FULL WTIfiOUT Tilt WRJTTEN APPROVAL OF THE LABORATORY 1000 i00.0 100.0 100.0 100.0 1000 100.0 1000