HomeMy WebLinkAboutVAIL LIONSHEAD FILING 1 BLOCK 1 LOT 6 UNIT Y LEGAL.pdfTOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGEROAD
LJ a .3\t t
U Ltr t5
VAIL, CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
PLUMBING PERMIT Permit #: P07-0157
Job Address: 450 LIONSHEAD CR VAIL Status . . . : ISSUED
Location.....: TREETOPS CONDOS CARAGE Applied . . : 09118/2007
Parcel No...: 21010640403 1 Issued..: 09/21/2007
Legal Description: Expires . ,: 0311912008
Project No :
OI^INER TREETOPS CONDOMINTUM ASSOC 09/a8/2007
? GREAT WEST MGMT & REALTY CO
320]- S TAIVIARAC 2OO
DENVER
co 80231
APPLICANT MEADOW MOUNTAIN PLITMBING/HEAOg/1,8/2007 Phone: 97O-479-298L
P.O. BOX 4554
co 81658
License: 288-P
CoNTRACTOR MEADOW MOUNTATN PLIIMBTNG/HEAO9/le/2007 Phone: 97O-479-29ar
P.O. BOX 4564
VAIL
co 8r.558
License: 288-P
Desciption: INSTALL 4" STORM SEWER LINES OFF GARAGE DRAINS TO EXISTING
STORM SEWER
Valuation: $5.668.00
Firepface Information: Restricted: ?? H ofGas Appliances: ?? # ofCas Logs: '!? # of Wood Pallet: ??
* *,i * *,|tt * **. * * *,*,i *
Plumbing--> $9o.oo Restuarant Plan Review-> 9o.Oo Totalcalculated Fees-> $115-50
Plan Check--> 122.5a TOTAL FEES--------> S115. so Additional Fees--------> 90.00
Investigation.> $0. oo Total Permit Fee-----> $r.16.50
Will Call----> 54. oo Palments-------------t $116. s0
BAIANCE DUE----> go. oo
* t *,r a r * a *t a*i + i * a i *t t r+ * +i r t r *t *r +
Item: O5l-00 BUILDING DEPARTMENT
09 /2O / 2007 JRM Action: AP
Item: 05500 FIRE DEPARTMENT
CONDITION OF APPROVAL
1ran^. T')
(BI".,DG.): FIEI-,D INSPECTfONS ARE REQUIRED TO CHECK FOR CODE COMPLTANCE.
*** l+*+ +*t+'r +,t*++*l* +it++tt+*+it++
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in fu|l the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, Intemational Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY.FOUR HOURS IN ADV BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4 PM.
OF OWNEROR CONTRACTOR FOR HIMSELF AND OWNEF
**************'t*t***t*****************||*|***|*|*ti**i.***it******'tt **t * * i l * * * * 't * * * * t * * t * * * * * *
TOWNOFVAIL. COLORADO Stat€ment
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * a +* ** ** i f **** *+** * * ** * * ** *** *l * **** * ** **ll**l ****** *
Statement Number: RO?0001934 Amount: $116.50 09/2I/2O0?10:14 Atrl
Palnnent Method: Check
PLumbing / ck ]-0192
IN1T: LT
Not,ation: Meadow Mountain
Permit No:
Parcel No:
Site Address :
Location:
This Payment :
ACCOI.JNT ITEM LIST:
Accounts code
PF 00100003L12300
PP 0 010 0 0 0311110 0
wc 00100003112800
P07-0157
2101-064-0403-1
4 5 O I.,IONSHEAD CR VAII,
TREETOPS CONDOS GARAGE
$116. s0
Descriptsion
r14)e: PLUI'IBING PERMIT
r* * * * * * * * * * * * * ** * | * * * * * * * * * * * * * * * * * * * * * *'t't *'t * * i:i,l* ** {. * * * * * * * * * * l. * * * * {.* * * * *** * * * * **1.{.***'r * * {. * *
Total Fees:
TOTAI AIJL PMIS :
Ba].ance:
$115.50
$116. s0
$0.00
Current Pmtss
PLAN CHECK FEES
P].,,WBING PERMIT FEES
V{ILL CALL INSPECTION FEE
22 .50 qn nn
4.00
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED
Proiect #:rc).ol,s7
tl fl j- rt)(TD tt ) rs -T lll, - ..NTpacr.,RTNF.RMATT.N
Building Permit #:
Plumbing Permit #:
97 0-479 -2149 (Inspections)
75 S. Frontage Rd.
Vail, Colorado 81657
Plumbing Contractor:
/tt,t''fr,-*.- ?/*^5ht
Town of Vail Req. No.:2trf Contact Person and Phone #'s:
Ae')c D-&.n 7aY'odTo
tc'c!<c"Cn
Contracto( Signature:l/a2*ta/L-
/ coMPLETE vALUATToN FoR PLUMBTNG PERMTT (Labor & Materials)
PLUMBING: S 5 669-?
Assessorc Office at 97O-328-864O or uisit
#()
Job Name: frc. 747t
PhoneiZea-
"fz-32 73 Owners N"a.rZtrn Zr.
Address,i l.a4e v.o 4, C-ct. f,atz-2
description of work: A
€a.:s /,",, J/...n
t 4 ?t"
Je *t-z
c.v..- /-\/at
WorkClass: New() Addition( ) Alterationffi Repair( ) Other( )
Type of Bldg.: Single-family ( ) Dupler ( ) Multi-family ( ) Commerciat 1NI nestaurant ( ) Other ( )
No. of Acommodation Units in this building:No. of Existing Dwelling Units in this building:
* ***** r(************* ************r(******FOR OFFICE USE ONLY**********'k********:k*****************
F:\cdev\FORMS\PERMITS\Building\plumbing-permit-1 1-23-2005.doc Page 1of 1 71123/2005
i . r I a, I a" ,.
',
t j\"
I
' i
t
/'-:\ -
Itfl'r..'\s/:/
ruwfrvAnlY
HOW DIDWE RATE WIIH YOU? . ig
Town of Vail Survey
Cornmunity Development Department Russell Fonesl Director, ''n . .
{970} 47s.2r3e
Check allthat applies.
1. Which Deparfnen(s) did you contact?
Buildino Environmental Housino Admin
Planning DRB
-.
PEC
2. Was your initial contact wiilt our stafi imrnediate_ slow _or :
no one available ?
3. lf you were required to walt how long was it before you were
helped?
4. Was your project reviewed on a timely basis? Yes / No
lf no, why not?_
5. Was tlris your first lime to file a DRB app- PEC app-
Bldg Permit_ N/A
6. Please rate the performance of the staff person who assisled you:
5432lName:
(knowledge; responsiveness, availability)
7. Overallefiectiveness of the Front Service Counter. 5 4 3 2 I
8. What is the best time of day for you to use he Front Service
Counter?
9. Any comments you have which would allow us to better serve you
nexttime?
Thank you for taking tlre lime to complete this survey, We are
commited b improving our service.
l,niotl#ot In"e""$3,1
F"duF".f BrPo*ing t"n" uo
RGquestod Inspect Date:- Inspection Area:
Site Address:
A/P/D Information
Activitv: P07-0157 Tvoe: B-PLMB
Const Tvp6: Occuoahbv:Onfrien TREETOPS CONDOMINIUM ASSOC
Contracton MEADOW MOUNTAIN PLUMBING/HEATING
Monday, Sept€mber 24, 2007
JRM
450 LIONSHEAD CR VAIL
TREETOPS CONDOS GARAGE
Sub Tvoe: AMF Status: ISSUED U'se: Insp Area: JRM
Phone: 970-4792981
OFF GARAGE DMINS TO EXISTING STORM SEWER
Requested Time: 09:00 AM ' Phone: 970-904-0070
Entered By: LTILLMAN K
lnsp€ctlon Historv
/^/ t\/-\'. I U
,,Y\ U\l,\ l\(/\r \ /\/
\ "210
220
230
240
250
260
290
Description: INSTALL 4:
REPT131 Rua Id: 7090
\$
F
\
\
\
*\N
$$\
\rj
\,N \
rti\i F.-F*i
t
\
f\
i:.I \\\>
s s
s I a
\
til irN .lF
s i
h
I
. St\\
\"
\
d
\
I
i
\
n
\
e
(.,\
\\
\-\\i
N"-\N q\
n
\
c\
d
\$
\
\\
1\'x'
\
\\i
fu;/ irx =L,r,J':e:J)^,r-7 ,,.1-r2t *.7r
| | Cond: CON0009594
Applicant to revise plans to indicate proposed finished grades and slope of
remodeled loading dock driveway surface. Such details should be provided with any
building permit submittal.
Cond: CON0009595
All new exterior materials, textures, colors and construction techniques are to
match those existing on the Tree Tops building.
Planner: Scot Hunn DRB Fee paid: $2SO.@
Minor Exterior Alterations
Application for Design Review
Depaft ment of Community Development
zs ioutn Frontage Road, Vail, colorado 81657
tel: 970.47i'2128 fax: 970 479'245?
web: www vailgov'com
ffil,T*llJ;JfrTl?l;. ,""** must receive approval prior to submittins a buirdins permit application Please
refer to the submittar ,..qu,r"n,."ii, roi tne par$cutai approval tt'rut-ii r"qu"it"a' An application for Design Review
cannot be accepted untir arr requirei' i.iJr[.,i", i, ii,*v"u lv ,t'" iJttunitv Development Department' The
Droiect may also need to ue ,elr"ie*lo'il il;i;*. councit.ail/or1he Rtanning and Environmental commission
beiign review upp.o.,ut_tupl.J;;il'" ;;"tldlngp"-ii'it'Lu.a ana "6ntttuttion
commences within
one Year of the apProval'
Description of the Request:
u P
E fl
(tl
0t o
,Physical Address:
(Contact Eagle Co. Assessor at 970-328-8640 for parcel no')
Parcel No.:
Zoning:
Name(s) of Owner(s):
{ailin9 Address:
Owner(s) Signature(s),:
Name of APPlicant:
Type of Review and Feel
tr Signs
E conceptual Review
tr New Construction
n Addition
Minor Alteration
(multFfamilY/commercial)
Minor Alteration
(sin gle-familY/duPlex)
Changes to Approved Plans
Sepamtion Request
r _-_=-.:R--.I L---,r r i
$50 Plus $1.00 per square foot of total sign area l , ' ii NoFee i- i-l
$65oForconstructionofanewbui|drngordemo/rebu'|,1..^,i;n".''F;>fifi ror in aoOition where sQuareloolln:,i:-1d3"d^j?,:ll i-L ...t""iJ irtifaing (includes 2s0 adlnions & interior cqntcrsionsL'' b
l(l
!
!
$250i"i'i""iin""g"'tdbui|dingsandsiteimprovem"'I';,1',.xxl3,,."o>
re-roofing, painting, window additions' landscapln
.^,.rc ar.
=
retaining walls, etc'
$20 ;;;i;;;";s* to buildinss and site improvements' Eughl as' C
re-roofing, paintrngr *indofo udditions' landscaping';qt: :t1-, F
retaining walls, etc'
$20 For revisions to prans already approved Uy etanning |6taR_F ---'
Design Review Boarcl
No Fee
t
***+**************{.*+t **i*{.,t *********** + * * + * * +* * ************r.:}*+x.*{.{.{r***** * * * * * * * * + * * * * * * * * +
TOWNOF VAIL, COLORADO StAtEMENt
***{.*!t,t***'t*****'}************++***+:}**{.*****{.:t************'r******,t:****tt++*{.***********'}*****
stsauements Nruiber: R0?0002235 Amount: $250 'oo Lo/L6/200710:41 AM
Payment Methoal: check rnits: JS
Notationr 14 ?34 /ERrTzr'EN
PIERCE ARCH
Permits No: DRBO7O585 Type: DRB-Minor Alts' comm/Multi
Parcel No: 2101-054-0403-1
Site Addrese: 450 LIoNSHEAD CR VA]L'
Location: TREETOPS DOCK/DRIVE Total Fees:
TOtAl ALI, PMtS :
Balance;
$2s0.00
$2s0.00
$0.00 This PaymenL :$250.0o
******+**{.**ld.********l*+****************************************r.**{.******{.****+**{.***:t***'}
ACCOUNT ITEM LIST:
Account Code De s cript ion Current Pmts
DESIGN REVIEW FEES 250.00
DR 001000031L2200
'ta
Treetops Condominium Association
450 E. Lionshead Circle
Vailo Colorado 81657
October l2,2OO7
Town of Vail
Deprtnent of Community Developmenl
75 S. Frontage Rd.
Vail, CO 81657
Re: Authorization of revisions to the loading dock and the
managenl deck area
To Whom ltMay Concern:
The Boacd of Directors of the Treetops Condominiunt
Association authorizes the pmposed revisions to the loading dock
and the manag,er's deck area.
) (*---....-!flt V -*.,,----.
JeffBrown
lvlanaging Agent
>\-d
(
Land Title Guarantee ComPanY
CUSTOMER DISTRIBUTION
Date: 10-15-2007 Our Order Number: V50020846
Property Address:
452E.LIONSHEADCIRCLEAKATREETOPSCONDOMINruMVAIL,COS165T
II you have any inquiries or requirc further assistance, please contact one of the numben below:
For Tide Assistance;
Vail Title Dept,
Chris McElvany
rO8 S FRONTAGE RI} W #203
VAIL, CO 81657
Phone: 9?0-47F2?51
Fax:070-47F4732
EMail: cmcelvany@ltgc.com
TREETOPS HOA
450 E. LIONSHEAD CIRCLE
VAIL. CO 81657
Attn: VICKI BROWN
EMail: vicki@wmcvail.com
Linked Commitrnent Delivery
m Land Title Guarantee Company
Date: l0-15-2007
Our Order Number: V50020846
Propert5r Address:
452 E. LIONSHEAD CIRCLE AKA TREETOPS CONDOMINIUM VAIL, CO 81657
Buyer/Borrower:
TREETOPS CONDOMINIUM ASSOCIATION, A COLORADO NON-PROFIT CORPORATION
Seller/Owner:
TREETOPS CONDOMINIUM ASSOCIATION, A COLORADO NON-PROFIT CORPORATION
Need a mao or directions for vour upcoming closing? Check out Land Title's web site at www.ltgc.com
for directidns to any of our 54 office locatiois. -
ESTIMATE OF TITLE FEES
Information Binder $783.00
If LejlJd Title Cuaranllee Cqrady rjilT be closittg this tla-asactioa, above fees $i77 be coafected eX thaX titu4 -
TOTAL 9783'oo
Fon comkt ocloa THANK YOU FOR YOUR ORDER!
LAND TITTE GUARANTEE COMPANY
tNvotcE
Owner:TREETOPS CONDOMINIUM ASSOCIATION, A COLORADO NON.PROFIT CORPORATI
Property Address: 452 E. LIONSHEAD CIRCLE AKA TREETOPS CONDOMINIUM VAIL, CO 81657
Your Reference No.:
When referring to this order, please reference our Order No. V50020846
- CHARGES -
Information Binder $183.00
*Total--$183.00
Please make checks payable to
Land Tide Guarantee Company
P.O. Box 5440
Denver, CO 80217
Chicago Title Insurance ComPanY
ALTA COMMITMENT
Schedule A
Our Order No. V50020846
Cust. Ref.:
Property Address:
452 E. LIONSHEAD CIRCLEAKATREETOPS CONDOMINIUMVAIL' CO 81657
l. Effective Date: October 02, 2007 at 5:00 P.M.
2. Policy to be Issued, and Proposed Insured:
Informalion Binder
Proposed Insured:
TREETOPS CONDOMINIUM ASSOCIATION, A COLORADO NON-PROFIT CORPORATION
3. The estate or interest in the land described or referred to in this Commitment and covered herein is:
A Fee Simple
4, Title to the estate or interest covered herein is at the effective date hereof vested in:
TREETOPS CONDOMINIUM ASSOCIATION, A COLORADO NON-PROFIT CORPORATION
5. The land referred to in this Commitment is described as follows:
SEE ATTACHED PAGE(S) FOR LEGAL DESCRIPTION
Our Order No: V50020846
tEGAt DESGRIPTION
COMMON AREA, BUILDING A, TREETOPS CONDOMINIUMS, ACCORDING TO THE MAP THEREOF
RECORDED NOVEMBER 11, 197I IN BOOK 222 AT PAGE 223 AND AS DESCRIBED IN
CONDOMINIUM DECLARATION FOR TREETOPS CONDOMINIUM RECORDED NOVEMBER 8, 197T IN
BOOK222 AT PAGE I9(), COUNTY OF EAGLE, STATE OF COLORADO.
COMMON AREA, BUILDING B, TREETOPS CONDOMINIUM, ACCORDING TO THE MAP THERI'OF
RECORDED SEPTEMBER 20,Iq7}IN BOOK 225 AT PAGE 44I AND AS DEFINED IN
CONDOMINIUM DECLARATION FOR TREETOPS CONDOMINIUM RECORDED NOVEMBER 8, 197I IN
BOOK222 AT PAGE I9O AND THE FIRST SUPPLEMENT TO SAID CONDOMINIUM DECLARATION
RECORDED SEPTEMBER 7, 1972 IN BOOK 225 AT PAGE 339 , COUNTY OF EAGLE, STATE OF
COLORADO.
ALTA COMMITMENT
ScheduleB-Sectionl
(Requirements) Our Order No' V50020846
The following are the requirements to be complied with:
Item (a) payment to or for the accounf of the grantors or morlgagors of the full consideration for the estate or
interest to be insured.
Item (b) proper instrument(s) creating the estale or interest to be insured must be executed and duly filed for record'
to-wit:
Item (c) payment of all taxes, charges or assessments levied and assessed against the subject premises which are due
and payable.
Item (d) Additional requirements, if any disclosed below:
This product is for informational purposes only and does not constitute any form of title guarantee nor insurance. The
liability of the company shall noiexieed the iharge pairl by the applicant for this product, nor shall the company be
held liable to any party other than the applicant for this product.
THIS COMMITMENT IS FOR INFORMATION ONLY, AND NO POLICY WILL BE ISSUED
PURSUANT HERETO.
ALTA COMMITMENT
ScheduleB-SeclionZ
(Exceptions) Our Order No' V50020846
The policy or policies to be issued will contain exceptions to the following unless the same are disposed
of to the satisfaction of the Company:
l. Rights or claims of parties in possession not shown by the public records'
2. Easements, or claims of easements, not shown by the public records'
3. Discrepancies, conflicts in boundary lines, shortage in area, encroachments, and any facs which a correct survey and
inspection of tlre premises would disclose and which are not shown by the public records.
q. Any lien, or right to a lien, for services, labor or material theretofore or hereafter furnished, imposed by law and
not shown by the Public records.
5. Defects, liens, encumbrances, adverse claims or other matters, if any, created, ffrst appearing in the public rerords or
attaching subsequent to the effective date hereof but prior to the date the proposed insured acquires of record for
value the estate or inlerest or mortgage tlereon covered by this Commitment'
6. Taxes or special assessmenls which are not shown as exisling liens by the public records.o the Treasurer's office.
7. Liens for unpaid water and sewer charges, if any..
g. In addition, the owner's policy will be subject to the mortgage, if any, noted in Section I of Schedule B hereof.
9. RIGHT OF PROPRIETOR OF A VEIN OR LODE TO EXTRACT AND REMOVE HIS ORE
THEREFROM SHOULD THE SAME BE FOUND TO PENETRATE OR INTERSECT THE PREMISES
AS RESERVED IN UNITED STATES PATENT RECORDED SEPTEMBER 04, 1923, IN BOOK
93 AT PAGE 98.
I(]. zuGHT OF WAY FOR DITCHES OR CANALS CONSTRUCTED BY THE AUTHORITY OF THE
UNITED STATES AS RESERVED IN UNITED STATES PATENT RECORDED SEPTEMBER 04'
1923, IN BOOK 93 AT PAGE 98.
1I . RESTRICTIVE COVENANTS WHICH DO NOT CONTAIN A FORFEITURE OR REVERTER CLAUSE,
BUT OMITTING ANY COVENANT OR RESTRICTION BASED ON RACE, COLOR, RELIGION,
SEX. HANDICAP, FAMILIAL STATUS OR NATIONAL ORIGIN UNLESS AND ONLY TO THE
EXTENT THAT SAID COVENANT (A) IS EXEMPT UNDER CHAPTER 42' SECTION 3607 OF
THE UNITED STATES CODE OR (B) RELATES TO HANDICAP BUT DOES NOT
DISCRIMINATE AGAINST HANDICAP PERSONS, AS CONTAINED IN INSTRUMENT RECORDED
MAY 18. 1970, IN BOOK 217 AT PAGE 675.
12. EASEMENTS, CONDITIONS, COVENANTS, RESTRICTIONS, RESERVATIONS AND NOTES ON
THE RECORDED PLAT OF VAIL/LIONSHEAD FIRST FILING.
ALTA COMMITMENT
ScheduleB-Section2
(Exceptions) Our Order No. V50020846
The policy or policies to be issued will contain exceptions to the following unless the same are disposed
of to the satisfaction of the Company:
13. TERMS. CONDITIONS AND PROVISIONS CONTAINED IN CONDOMINIUM DECLARATION FOR
TREETOPS CONDOMINIUM RECORDED NOVEMBER 8, I97I IN BOOK222 AT PAGE 190 AND
THE FIRST SUPPLEMENT TO SA]D DECLARATION RECORDED SEPTEMBER 7, 1972 IN
BOOK 255 AT PAGE 339 AND RESOLUTION RECORDED JUNE 25, 1984 IN BOOK 387 AT
PAGE 925 AND AFFIDAVIT RECORDED NOVEMBER 30, 1984 IN BOOK 401 AT PAGE 194.
14. EASEMENTS, CONDITIONS, COVENANTS, RESTRICTIONS, RESERVATIONS AND NOTES ON
THE CONDOMINIUM MAP OF TREETOPS CODNOMINIUMS RECORDED NOVEMBER II, I97I IN
BOOKZ22 AT PAGE 223,
(THE ABOVE ITEM AFFECTS BUILDING A)
15. EASEMENTS, CONDITIONS, COVENANTS, RESTRICTIONS, RESERVATIONS AND NOTES ON
THE CONDOMINIUM MAP OF TREETOPS CONDOMINIUMS RECORDED SEPTEMBER ZO,1972
IN BOOK 225 AT PAGE 44I.
(THE ABOVE ITEM AFFECTS BUILDING B)
16. TERMS, CONDITIONS AND PROVISIONS OF AGREEMENT RECORDED DECEMBER 17, 1984 IN
BOOK 402 AT PAGE 2I2.
17. TERMS, CONDITIONS AND PROVISIONS OF BROADBAND EASEMENTAND RIGHT OF ENTRY
AGREEMENT RECORDED JULY 02, 1997 IN BOOK 73I AT PAGE 17.
LAND TITLE GUARANTEE COMPANY ANd LAND TITLE GUARANTEE COMPANY - GRAND JUNCTION
DISCLOSURE STATEMENTS
Note: Pursuant to CRS 10-11-122, notice is hereby given that:
A) The subject real property may be located in a special taxing district'
Bi A Certificate of ia"es Due listing each taxing jurisdiction may be obtained from the County
Treasurer's authorized agent'
C) The information regarding special districts and the boundaries of such districts may be obtained from
the Board of County Commissioners, the County Clerk and Recorder, or the Counff Assessor.
Note: Effective September l, 1997, CRS 30-10-406 requires that all documents received for recording or filing
in the clerk and recorder's office shall contain a top margin of at least one inch and a left, right and bottom
margin of at least one half of an inch. The clerk and recorder may refuse to record or file any document that
doeinot conform, except that, the requirement for the top margin shall not apply to documents using forms
on which space is provided for recording or filing information at the top margin of the document.
Note: Colorado Division of Insurance Regulations 3-5-1, Paragraph C of Article VII requires that "Every
title entity shall be responsible for all matters which appear of record prior to the time of recording
whenevei the title entity conducts the closing and is responsible for recording or filing of legal
documents resulting from the transaction which was closed". Provided that Land Title Guarantee
Company conductJthe closing of the insured ransaction and is responsible for recording the
legal doiumen6 from the transaction, exception number 5 will not appear on the Owner's Title
Policy and the Lenders Policy when issued.
Note: Affirmative mechanic's lien protection for the Owner may be available (typically by deletion
of Exception no. 4 of Schedule B, Section 2 of the Commitment from the Owner's Policy to be
issued) upon compliance with the following conditions:
A) The lind desciibed in Schedule A of this commitment must be a single family residence which
includes a condominium or townhouse unit.
B) No labor or materials have been furnished by mechanics or malerial-men for purposes of
constmction on the land described in Schedule A of this Commitment within the past 6 months.
C) The Company must receive an appropriate aflidavit indemniffing the Company against un-filed
mechanic's and material-men's liens.
D) The Company must receive payment of the appropriate premium'
E) If there his been constructio;,
'improvements
or major repairs undertaken on the property to be purchased
within six monlhs prior to lhe Date of the Commitment, the requirements to oblain coverage
for unrecorded liens will include: disclosure of cerlain construction information; financial information
as to the seller, the builder and or the conlraclor; payment of lhe appropriate premium fully
executed Indemnity Agreements satisfactory to the company, and, any additional requirements
as may be necessary after an examination of the aforesaid information by the company.
No coverage will be given under any circumstances for labor or material for which the insured
has contracted for or agreed to pay.
Note: Pursuant to CRS 10-11-123, notice is hereby givenl
This notice applies to owner's policy commitnents containing a mineral severance instmment
exception, or exceptions, in Schedule B, Section 2.
A) That lhere is recorded evidence that a mineral estate has been severed, leased, or otherwise
conveyed from the surface estate and that there is a substantial likelihood that a third party
holds iome or all interest in oil, gas, other minerals, or geothermal energy in the property; and
B) That such mineral estate may include the right to enter and use the property without the
surface owner's Permission.
Nothing herein conlained will be deemed to obligate the company to provide any of the coverages
referred to herein unless the above conditions are fully satisfied'
Form DISCLOSLEE O9/AI/02
NOTICE OF PRIVACY POLICY
Fidelity National Financial Group of Companies / Chicago Title Insurance Company
Security Union Title Insurance Company
JulY 1' 2001
We recosnize and respect the privacy expecradons of today's consumers and the regll-irem-ents of aoolicable federal and
srate oriv-acv laws. W-e n"uevetitrii rdalifi;l;"-ilr*-;aii"w we use your non-public personal inf6imalio.n ("Personal
Informadon'), and to whom ii il'fij.ft;.,'fifiIt-fiii'.^tt'i, tiils'ioiii6litionshlf of rru'st beween.us and the public
iffiffi.ii*i,d.'riii' F'ii,iiv-s-r^,iLilliiipi""';rdli'd'ii'&ii.ilalon.-we reseru" rhi right to change this Privacv-
Si;i";;;i}iom ii;e o tinie consistent'with applicable'privacy laws'
In the course of our business, we may collect Personal Information about you from the following sources:
+ From applicalions or olher forms we receive from you or your aulftorized representative;- iffi;;'"fiilili-.iii,"l *itrtl ,ii r"i;'tff;;iil 6.i"g pirformed by, us, o'ur afliliates. or others:
* From bur internet web sites;- i i6iii ift,i ilFli;;;rd;;iirt"in.d_ by gove_rnmental entities rhat we either obmin directly from those
enlities. oi from our affiliates or others; and * From consumer or other reporting agencies.
Our policies Regarding the Protection of the Confidentiality and Security of Your Personal Information
We mainlain physical, electronic and procedural safgguards to protect your Personal Information from unautlorized
j"i"ji-i,i'inrrili-io'i. W. iin1iri'ii.'i|iJilt;"f;;"JifiiJfiaaof o"ty td those.employees who need such access in
;ffi;ti";i1-h;i;;riOitid piia"-cts oi ierui."i io you or lor other l6gitimale buslneis purposes.
ourPoliciesandPracticesRegardingtheSharingofYourPersonallnformation
We mav share your Personal Infon4ation, with our.affiliates, such as ingurance companies, agents, and other real
JJ[t'ii'"uft".r.,iiri'ii1if;;;ridffi. W;-aiso may disctose your Personal Informatjon:
* to agents, brokers or representatives to provide you with services you have- requested;* ro tfiird-parry .onrrq.tg-rs ii"i";i;p;;iid;;;h provide servicis or perforni marketing or other
function3 ori our behalf; and * to others with whomIv. ini-.. into joint marketing agreements for products or services that we believe you
may find of interest.
ln addidon, we will disclose your Personal Information.w\en vou direcr or give us permission, when we are required
bv law ro do so, or *r'"n *""iii".i'ir;ifr;i;;i;;;;i;iili ;'li;itid.-we a-fso may disclose vour Personal
Iiformadon when otherwise fff,irr;d [i rj;iil;ii,t" iliiu*v ii*J suitr as, ror exa'mple, wheh disclosure is needed
i;;r6;;;il;;ighrJ-arising fiii iT-iirvTgide'r"eni. trlnsacrion or relarionship with ybu.
One of rhe important responsibiliiies of some of our.afliliated companies is to record documents in lhe public
Odin"in. Sucl'aocumenti may contain your Personal Infbrmation'
Right to Access Your Personal Information and Ability to correct Errors or Request changes or Deletion
Certain stares afford you the right lo access yo,ur fersonal.Inlormation and, under. cenain circumstances' to find out
i"'i"fiiiitt""i,""r Fliltirijrfti1n?ii;iitras neeil aisctosgd, Also. certain slates afford you the rieht to requesl
correcrioi. amendmenr ot t.iiij|i'ltvoii p'*iioiiit"-r"rmarion. we reserve the rilhr, wherE permitl'ed by law, to
charge a reasonable fee to cover the costs incurred in responding to sucn requesrs'
All reouesrs submitted f o the Fidelity Na,tiq,nal Financial Group of Companies/Chicago Title Insurance Company
shall b'e in writing, and delivered to the following address:
Privacv ComDliance Officer
Fidelitl Nati6nal Financial' Inc.
3::gg*f;.Tf:ti"df'14'
Multiple Products or Services
If we orovide you with more than one financial. product or service, you may receive more than one privacy notice
from ris. We apologize for any irconven.ience this may cause you'
Form PRIV. POL.CHI
NOTICE OF PRIVACY POLICY OF
LANDTITLEGUARANTEECOMPANY,INc.,ACoLoRADoCoRPORATION
AND
MERIDIANLANDTITLE,L.L.C.,AcoLoRADoLIMITEDLIABLITYCoMPANY'D/B/A
LAND TITLE GUARANTEE COMPANY - GRAND JUNCTION
This Statement is provided to you as a customet of Land Title Guarantee Company, a Colorado corporation and
Meridian Lan6 Tiile, LLC, dlb/a Land Title Guarantee Company - Grand Junction.
We want you to know that we recognize and respect your privacy expectations and the requirements of federal
and stare irivacy laws. Informatiorisecurity is one oi our highest priorities. We recognize that maintaining your
trust and confidence is the bedrock of our business. We maintain and regularly review internal and external
safeguards against unauthorized access to non-public personal information ("Personal Information") '
In the course of our business, we may collect Personal Information about you from:
+ applications or other forms we r;ceive from you, including communications sent through TMX, our
web-based transaction management system;* your transactions with, or fiom the Jervices being performed by' us' our affiliates' or others:
* a consumer reporting agency, if such information is provided to us in connection with your transaction;
and * the public records maintained by governmental entities thal we either obtain direcdy from those entities,
or from our alliliates and non-affiliates.
Our policies regarding the plotection of the confidentiality and securi$ of your Personal lnformation are as
follows:* We restrict access to all Personal Information about you to those employees who need to know that
information in order to provide products and services to you'
* We maintain physical, etectro"ic and procedural safeguards that comply with federal slandards to
protect your Personal Information from unauthorized access or intrusion'
* 'Employees who violate our strict policies and procedures regarding privacy are subject to disciplinary
action.* We regularly access security standards and procedures to protect against unauthorized access to Personal
Information .
ANY PURPOSE THAT IS NOT PERMITTED BY LAW.
consistent with applicable privacy laws, there are some situations in which Personal Information may be
disclosed. We may tlisclose your Personal Information when you direct or give us permission; when we are
requirert by law to do so, foi example, if we are served a subpoena; or when, we suspect fraudulent or
criminal activities. We also may disclose your Personal Information when otherwise permitled by applicable
privacy laws such as, for atu.pl", when iisclosure is needed to enforce our rights arising out of any agreement'
transaction or relationship with you.
our policy regarding dispute resolution is as follows. Any controversy or claim arising out of or relating to our
pJr*y plfi.V;, or th'e breach thereof, shall be settled by irbitration in accordance with the rules of lle American
irnitration Association, and judgment upon the award rendered by the arbitrator(s) may be entered in any court
having jurisdiction thereof .
Fcrm PRIV.POL.LTG.l
WUonthouL /s*
/dl-b t bllcl
co\*iJMT\r Ct\tELOelEf{r
Design Review Board
ACTION FORM
Department of Comrnunity Developrnent
75 South Frontage Road, Vail, Colorado 81657
tel: 970.479.2139 fax: 970.479.2452
web: www.vailgov,com
Project Name: TREETOPS EXTERIOR
Project Description:
Participants:
Project Address:
TREETOPS DOCK/DRIVE
Legal Description:
Parcel Number:
Comments:
DRB Number! DR8070586
FINAL APPROVAL FOR THETREETOPS EXTERIOR RENOVANON
MoUon By:
Second By:
Vote:
Conditions:
DuBois
Dunning
5-0-0
owNER TREETOPS CONDOMINIUM ASSOC 10/16/2007
o/o GREAT WEST MGMT & REALTY CO
3201 S TAMAMC 200
DENVER
co 80231
APPUCANT TREETOPS CONDOMINIUM ASSOC 10/16/2007 Phone: 970-471-0805
]EFF BROWN,GEN. MGR.
3201 S TAMAMC 200
DENVER
co 80231
450 UONSHEAD CR VAIL Location:
Lot: 6 Block: Subdivision: Vail Lionshead Filing 1
2101-064-0403-1
BOARD/STAFF ACTION
Act.on: APPROVED
Date of ApprovaL lll 07 l2OO7
ttfz/o7
Cond:8
(PLAN): No changes to these plans may be made without the written consent of Town of
Vail staff and/or the appropriate review committee(s).
Cond: 0
(PLAN): DRB approval does not constitute a permit for building. Please consult with
Town of Vail Building personnel prior to construction activities.
Cond: 201
DRB approval shall not become valid for 20 days following the date of approval,
pursuant to the Vail Town Code, Chapter 12-3-3: APPEALS.
Cond: 202
Approval of this project shall lapse and become void one (1) year following the date
of final approval, unless a building permit is issued and construction is commenced
and is diligently pursued toward completion.
L.'\ C'
Ur.,,\ t_ t\ r 3
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGEROAD
VAIL, CO 81657 .:\.-r-l z-1-,-'\
i 970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ADD/ALT COMM BUILD PERMT Permit #: BO5-0137
Valuation: $19,500.00
Fireplace Information: Restricted:
Status...: ISSUED
Applied. . : 06lWl2W5 Issued...: O6l06l20[j
Expires...: l2ll3l2ffi5
Add Sq Ft: 0
# ofcas Appliances: 0 # ofcas t gs: 0 # of Wood Pellet: 0
90.00 Total Calculated Fees-> 9s33. oG
$0. 00 Additiodal Fe€s-------> $0 . 00
$0-00 Total Permit Fee-------> 5533.06
Job Address: 450 LIONSHEAD CR VAIL
Location.......: TREETOPS CONDO WEST
ParcelNo....: 210106404031
Project No . : (r1 af_o ef
o!\rNER TREETOPS COIIDOMTNIITM ASSOC O5/O2/2OO'
T GREAT WEST MGMT & REALTY CO
3201 S TAMARAC 2OO
DENVER
co 80231
APPIrICAlilt TCC CONTRACTORS, INC. 06/02/2005 phone: 97O-328-2340
P.O. BOX 2123
EAGI,E
co 81631
License:540-B
CoNTRACTOR TCC COIITRjACTORS, INC. 06/02/2OO5 phone: 970-328-2340
P.O. BOX 2723
EAGI,E
co 81_631
Iricense: 540-B
Desciption:
TO ADD s/8" PLYWOOD AND 40 YEAR ELK (ASPEN WHrTE) ASPHALT
SHINGLES. ALSO ADD GUTTERS AND HEAT TO THIS AREA. APPROX.
1404 sQ FT OF SHED ROOFS (4 AREAS)
Occupancy:
Type Construction:
Tlpe Occupancy: ??
****,t,t**)t*****,***)t:s:**:*:******,r,rr*ri*rirtr.:iri,*'i*'t*:i***,i*+ri,t****,*,**,a:r+*:ltr,r,r* FEE SUMMARY
Building---> i32L.25 Resoarant Plan Review-->
Plan Check--> S208.81 DRB Fee--------------------- >
lnvestigadon->
Will Call--->
so. oo Recreation Fee-------->
93.00 Clean-up Deposit------> 90.00 Payments*--------- > 9533 - 05
TOTAL FEES------------- > $s33.05 BALANCE DUE-----> $0.00
Approvals:
Item: 05100 BUIIJDING DEPARTMEIiII
05/06/2005 fs Action: AP
Item: 05400 PLANNING DEPARTMENT
Item: 05600 FrRE DEPARTMENT
Item: 05500 PI]BLIC WORKS
See page 2 of this Document for any conditions that may apply to this permit.
PAGE 2 ************i.****{.******:**rF***t **{*****************t *************************************,t ,t :t +++*+++,F*:F***
CONDITIONS OF APPROVAL
Permit#: 805-0137 asof06-06-2005 Status: ISSUED *'*'***,*{t{t*,fitt*{t!t*!&*+:t:t,F*!****tt*********i(**rt***************i(**t&!e**********:f **********,t!fr!t!t,8*:t,F,Ft ,F*.*:F++***{.4(**
Permit Type: ADD/ALT COMM BUILD PERMT Applied: Ml}zt2CfJis
Applicant: Tcc coNTRAcroRS,INc. Issued: o6le6tzCf,i5 970-328-2340 To Expire: tltCP,tzns
Job Address: 450 LIONSHEAD CR VAIL
Location: TREETOPS CONDO WEST
Parcel No: 2101064M031
Description:
TO ADD 5/8' PLYWOOD AND 40 YEAR ELK (ASPEN WHITE) ASPHALT
SHINGLES. ALSO ADD GUTTERS AND HEAT TO THIS AREA. APPROX.
1404 sQ FT OF SHED ROOFS (4 AREAS)
Conditionsl
Cond: I
(FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY
WORK CAN BE STARTED.
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE
COMPLIANCE.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in flrll the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design
review approved, Uniform Building Code and other ordinances ofthe Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWEMY-FOI,'R
PM.
HOURS IN ADVANCE BY AT OUR OFFICE FROM 8:m AM - 4
FOR HIMSELF AND OWNEF
+++*++*+++++++++++++++**+*tt*++++**+++++*+***** ********** *** **++*****,* *** * ************** *** * *
TOWNOFVAIL, COLORADO Statement *+**++**************************+';+**l ************+*********** *++*********++** +****+*++*+ +**
Statement Number: R050000762
Palment Method: Check
Cotltraetors / ck 2566
Amount: $533 .05 06/06/?OO'OL:58 PM
Init: LT
Notation: TeC
Permit No: 805-01_3? Type: ADD/ALT COMM BUILD pERIitT
Parcel No: 2101- 0 64 - 04 03 - 1-
Site Address: 450 IJIONSHEAD CR VAIL
L,ocat,ion : TREETOPS CONDO V|EST
Total Fees:This Pavrnent ;$s33 .05 TotaL AIJJ Pmtr:
$533 .05
$s33 .05
Balance: $0.00
'f********++**********'1.'t*+**+*'i*********************++***+**+*********++:!'t *,1{r******'t **,}'ttt****
ACCOUNT ITEM LIST:
Account Code Description Current Pmt6
BP 0 010 000311110 0
PF 00100003 ]-72300
wc 00100003112800
BUIIJDING PERMIT FEES
PIJAN CI{ECK FEES
WIIJIJ CA]'I.' INSPECTION FEE
5ZL. Z)
208 .87
3.00
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED
Project #:
mwn0Fvtn
75 S. Frontage Rd.
Vail, Colorado 81657
ffiFOROFFICEUSEONLYry.I i.,, r,1..tlL--
1 Q r/ -t : {'r' l'i'[!]"i';
tl
CONTRACTOR INFORMATION
GeneralContractor: fCC
,(rnlrz* (orrhn l,.
Town of Vail Reg. No.:
5'/o - B
Contact and Phone #'s: 3Z* Zstzo
/L'rtt- S-<t/-o. 7 q.L q-i/c
Email addl#ss:/
ContractorSignature: 0-A"-.-'.*-
COMPLETE VALUATIONS FOR BUILDING PERMIT (LAbOr & MAIET|AIS
BUILDING: $ELECTRICAL: $OTHER: $
PLUMBING: $MECHANICAL: $TOTAL:$ f ?,'r0l)
For Parcel # Contact Assessors Office at 970-328-8640 or visit
A/o/ob (o(o3/
Job Address: /fO f -ukurs lct/Job Name: {trr fays
subdivision: /tfe/'
: /6sot. Up
of work: Ta Add 7a ."tyaoo d @-f-Bzr\c-o Le-vr\y i i_e- =/a/"_,
WorkClass: New() Addition( ) Remodel ( ) Repdir( ) Demo( ) Other( )
Does an EHU exist at this location: Yes ( ) No ( )WorkType: Interior( ) Exterior( ) Both( )
Type of Bldg.: single-family ( ) Two-family ( ) Multi-family ( ) commercial ( ) Restaurant ( ) other ( )
No. of Accommodation Units in this building:No. of Existing Dwelling Units in this building:
GasAooliances( ) GasLoqs( ) Wood/Pellet( ) Wood
Gas Loos ( ) Wood/Pellet ( ) Wood Burning (NOT ALLOWED
Documene 05t20n005
'.. i
{l,' | | 1,. -l I o
43\l
Project Name:
Project Description:
DESIGN REVIEW BOARD
ACTION FORM
Department of C.ommunity Development
75 South Frontage Road, West
Vail, CO 81557
tel: 970-479-2138 fax:. 970-479-245?
web: www.vailgov,com
?? DRB Number: DRB050212
Application Type:
TO ADD |-AMARTTE SrATE CTAMCO) TO 4 SLOPED SECTTONS OF ROOF ON TOp OF TREE TOPS
CONDOMINIUMS, ALSO ADD WHITE GUTIERS AND FACIA AND HEATTAPE.
Participants:
owNER TREETOPS CONDOMINIUM ASSOC 05/20/2005
o/o GREAT WEST MGfqT & REALTY CO
3201 S TAMAMC 200
DENVER
co 80231
APPUCANT TCC COI.ITRACTORS, INC.
P.O. BOX 2123
EAGLE
co 81631
License: 540-8
CONTMCTOR TCC CONTMCTORS, INC.
P.O. BOX 2123
EAGLE
co 81631
License; 540-8
ProjectAddress: 450 UONSHEAD CRVAIL
TREETOPS CONDO WEST
0512012005 Phone: 970-328-2340
0s/20/200s Phone: 970-328-2340
Locationr
tegal Description: Lot: 5 Elock SuMivision: Vail Lionshead Filing 1 Parcel Number: 2101-064-0403-1
Comments: See Conditions
BOARD/STAFF ACIION
Motion By:
Second By:
Vote:
Conditionsr
Peter Dunning
Sherry Dorward
4-0-0
Action: APPROVED
Date of Approvah 06107/2A05
Meeting Date: 06/0U2005
Cond:8
(PLAN): No changes to these plans may be made without the written consent of Town of
Vail staff and/or the appropriate review committee(s).
C.ond: 0
(PLAN): DRB approval does not constitute a permit for building. Please consult with
Town of Vail Building personnel prior to construction activities.
Cond: 201
DRB approval shall not become valid for 20 days following the date of approval.
Cond: 202
Approval of this project shall lapse and become void one (1) year following the date
of final approval, unless a building permit is issued and construction is commenced
and is diligently pursued toward completion.
Planner: Warren Campbell DRB Fee Paid: ??
Design Review Board Tez;fops
ACTION FORM
Departnent of Community Development
75 South Frontage Road, Vail, Colorado 81657
tel: 970.479.2t9 taxl 970.479.2452
web: www.ci.vail.co.us
Project Name:
Project DescrlpUoni
TO ADD 5/8' PLYWOOD AND 40 YEAR ELK (ASPEN WHTE) ASPHALT SHINGLES. ALSO ADD
GUTTERS AND HEAT TO THIS AREA. APPROX. 1404 SQ FT OF SHED ROOFS (4 AREAS)
Partlcipants:
owNER TREETOPSCONDOMTNTUMASSOC 04/18/2005
o/o GREAT WEST MGMT & REALTY CO
3201 S TAMAMC 200
DENVER
co 80231
APPLICAI.IT TCC CONTMCIORS, INC. 0411812005 Phone: 970-328-2340
P.O. BOX 2123
EAGLE
co 81631
License; 540-8
CONTMCTORTCCCONTMC|ORS, INC. 04/18/2005 Phone: 970-328-2340
P.O. BOX 2123
EAGLE
co 81631
Licensel 540-8
Project Address: 450 UONSHEAD CR VAIL Location:
TREETOPS CONDO WEST
Legal Description: loh Block Subdivision;TREETOPSCONDO
Parcel Number: 2101-064-0403-1
Comments:
BOARD/STAFF ACIION
Motion By:
Second By:
Vote:
CondiUons:
Planner: Bill Gibson
TOI4'N#
Lftrtry I
lof'b, blb I
DRB Number: DR8050153 -f.ceho(
Action: WITHDRWN
Date of Approval:
DRB Fee Paid: 1250.00
T0ltTvm
Description of the Request: Tb A f, J 5/:/
(4sPe^: u:hi-t€;\ * r"halr-s
General Informationl
All projecG requiring design review must receive approval prior to submitting a building permit application. please
refer to the submittal requirements for the particular approval that is requested. An application for Design Review
cannot be accepted until all required information is received by the Community Development Departmlnt. The
project may also need to be reviewed by the Town Council and/or the Planning and Environmental Commission.
Design review approval lapses unless a building permit is issued and construction commences within
one year of the approval.
wr:oJ €- *o
Name(s)of owner(s): -i'V-. 1uP= Qo pJo /+s=o C-
Mailing Address:
I Phone: zllG- Gq8>-
|Owner(s) Signature(s):
Name of Applicant:CL
Parcel No.: a I D I o6\-o + 03 t (contact Eagle co. Assessor at 970-328-8640 for parcet no.)
Zoning:
o
a -v
o
-,n ln
Mrnor Exterior Alterations
Application for Design Review
Department of Community Development
75 South Frontage Road, Vail, Colorado 81657
teli 97 0.479.2739 fax: 97 0.479.2452 ' web: www,vailoov.com
({u'9
Mailing Address:
E-mail Address:
Phone:
Fax:11O-z:zK-2-o77
Locationofthe Proposal: Lat: 6 gock:
Physical Address:
G.qlo- 3 z3- 2-3+o
Type of Review and Fee:
tr Signs
C Conceptual Review
E New Constructton - -/:-. -| ,faottton
I Minor Alteration
(multi-family/commercial)
O Minor Alteration
(single{amily/duplex)
E Changes to Approved Plans
tr Separation Request
$s0
No Fee
$6s0
$300
__,-=\(w
$20
$20
No Fee
Plus $1.00 per square foot of total sign area.
For construdion of a new building or demo/rebuild.
For an addition where square footage is added to any residential or
commercial building (includes 250 additions & interior conversions).
For minor changes to buildings and site improvemenG, such as,
reroofing, painting, window additions, landscaping, fences and
retaining walls, etc.
For minor changes to buildings and site improvements, such as,
reroofing. painting, window additions, landscaping, fences and
retaining walls, etc.
For revisions to plans already approved by Planning Staff or the
Design Review aourd.
,
L of 72104128104
Treetops DRB comments from May 4,2004,
Meeting
. Asphalt shingles are not appropriate for a building as contemporary as Treetops which
has "clean lines".o Asphalt is more of a residential application. Examine other roofing options which would
complement the architecture of the structure.o A change in color from white may help to provide an accent to the building.
Department of Community D evelopment
75 South Frontage Road
Vail, Colorado 81657
970-479-2138
FAX 970-479-2452
www,vailgov.com
TCC Roofing Contractors
George Sisneros
PO Box 2123
Eagle, CO 81631
May 6, 2005
Re: Re-roof of Treetops located at452 Lionshead Circle/Lot 6, VailLionshead Filing 1
Mr. Sisneros,
This letter is belng sent as a follow-up to the Design review Board hearing held on May 4,
2005, at which your item was tabled. The following are comments made by the Design Review
Board.
. Asphalt shingles are not appropriate for a building as contemporary as Treetops which
has "clean lines".. Asphalt is more of a residential application. Examine other roofing options which would
complement the architecture of the structure.o A change in color from white may help to provide an accent to the building.
Please review these comments and if you have any questions regarding this letter please
contact me at 970-479-2148. I will be out on vacation form May 14 through the 31. ln order to
be on the May 18, 2005, Design Review Board agenda I must have the roofing material you
would like to utilize on Treetops submifted by no later than noon on May 13, 2005. lf you are
unable to make a roofing selection and submit on May 13 you will be scheduled on the June 1,
2005 Design Review Board agenda if a roofing material is submitted by May 27, 2005.
*j,:f"n".", /
W"A/'##,*V,
Senior Planner
rD rt I
Cc:File
NACTCLED PIPBN
*** * **** ****+**+** *+ ++**++ + ++++ + * **+*****+{. * *** * ** ***** **********t** **** * * *** ++ * * * +* ********
TOWNOFVAIL, COLORADO Statement
* * *+***++++ +*** ** 't********+ +*lr+** ***** {. * **** ***+* ********+***++ **+* * * * *:}++* ** * * * +* **** ** *** *
Statement Number: R050000421 Amount.: $250.00 04/L8/2O05O3:45 PM
Pa)tment Method: Check
col{TRiacToRs
Inj.t ; ,fS
Notation: #238L/TCC
Permit No:
Parcel No:
Site Address :
Locatsi-on :
This Payment :
DR8050153 TIT)e:
2101-064-0403-1
450 LIONSHEAD CR VAIL
TREETOPS COI{DO WEST
tt<n nn
DRB-Minoi A1t, conrn/Multi
Total- Fees: $250 . 00
Totaf ALL Pmts: 9250.00 Balance: $0.00 *****.3**{r********i***'*++++*++**+******************,**,r**rr**t *************!F,}+******************
ACCOUNT ITEM LIST:
Accourt Code Description Cunent Pmts
DR 00100003'tL2200 DESIGN REVIEW FEES 250 . OO
MINOR EXTERIOR ALTERATIONS
TO BUILDING AND SITE IMPROVEMENTS
SUBMITTAL REQUIREMENTS
General Information:
This application is required for proposals involving minor exterior alterations and/or site
improvements. Proposals to add landscaping do not require DRB approval unless they involve
the addition of patios, water features, grading, or the addition of retaining walls.
I. SUBMITTAL REQUIREMENTS**
All pages of Application are complete
Checklist is completed and signed
Stamped Topographic Survey*, if applicable
Site and Grading Plan*, if applicable
Landscape Plan*, if applicable
Architectural Elevations*, if applicable
Exterior color and material samples and specificatio n , /
Architectural Floor Plans*, if applicable
Lighting Plan* and Cut-sheet(s) for proposed fixtures, if applicable
Title report, including Schedules A & B to verify ownership and easemenb*
Photos of the existing site and adjacent structures, where applicable.
Written approval from a condominium association, landlord, and joint owner, if
applicable
Site-specific Geological Hazard Report, if applicable*
The Administrator and/or DRB may require the submission of additional plans,
drawings, specifications, samples and other materials (including a model) if deemed
necessary to determine whether a project will comply with Design Guidelines or if the
intent of the proposal is not clearly indicated.
Please submit three (3) copies of the materiols noted with un usterisk (*).
xxFor interior conversions with no exterior chanqes, the submittal requirements include a
complete set of existing and proposed floor plans, a title report, and written approval from a
condominium association, landlord, and joint owner, if applicable.
I have read and understand the above
Project Name:
Contractor Signature
o '/Q 'd
,9.F
,o iF
arfr \P
)'o -/F
W w
D
Date Signed
Buildino Materials
PROPOSED MATERIAIS
Tyoe of Material Color
Roof
Siding
Other Wall Materials
Fascia
SoffitS
Windows
Wndow Trim
Doors
Door Trim
Hand or Deck Rails
Flues
Flashing
Chimneys
Trash Enclosures
Greenhouses
Retaining Walls
Exterior Lighting
Other
ro yer+rr I ptn* l{ 5lr r,r ?/e5 .r: h; €
ilA
NA
^1ft
NT
^lt
Nrt
N*
i)rl @
5" K-.sr*dta- e.'N=s-\:5q %&.N-
Pleasb specify the manufacturer's name, the color name and number and attach a color chip.
tla
MA
,J+
NA
Notes:
PROPOSED LANDSCAPING
Botanical Name Common Name OuantiW Size
PROPOSED TREES
AND SHRUBS
EXISTING TREES
TO BE REMOVED
Minimum Requirements for Landscaping: Deciduous Trees - 2" Caliper
Coniferous Trees - 6'in height
Shrubs - 5 Gal.
Type Square Footaqe
GROUND COVER
soD
SEED
IRRIGATION
TYPE OF EROSION CONTROL
Please speciff other landscape features (i.e. retaining walls, fences, swimming pools, etc.)
oa/uo/?vll ur: 16 ta.l'
c
J ?(fr
P1 tn r
+
f t-
P q Y
.+
7>l a p
,
Y,
t-
l-q )p
,
Y,
t-
l-q f
I I c
=4 17 -Kl
N +-+
t_7 --il
e)q \j{
+?b'
I
F n^l $_/
a
I P tr I I (;
Y ilQ\
t.J I S/f)<.5 IF,b:F
Fl er(o -'
,b e
P
-
F r
?
a1*'rtt-l x4 €7
trKr
o)+-+
-N e)q \jl
+T b'
U
F n^l $_/
a
I f3 tr I I (;
Y ilo\
t.J I S/f)<.5 IF,b:F
Fl er(oa
OV trl
b
CA
!q
Fl tl tl tl tl tl tl rt
-
(a
q)
(D
E
a'
+
5
o
a)
(D
o !.a
oq (D
o
Ft
-trt o
go 0F
F 8€A-E R
5{ii 9' oX aitr b-FQ r!<
:J<qt
PO
=Fl g-o
cn
o D
Ef
3
oa l;
U g)
CD
l$
lcrt
h
I
Ed t-t
O)o >r
tD
v)
E o Ft
F o o
E
oq (t)F E
D)Ft
('0
c (,\t
(t)
a.I
tJl
6 OO
t^J !)v,
*
(D
o
trr F
,+1
r-t
ztr
H
oo s
o t,
*
;
t.-J vl
C'\
I @ o\o o\*
Xlr
ooY
i {(a
O\ -Y $n F \o .D
--l
Ed Ft
ot ()fr o
vt
€o Ft
F o o
oc (n
€E
Fl
e
r'l t
J
.,b IB
f-(2 --
a
,t Lf\ --l
-l) -l'
-:) .-( ,r)\/-l.n (-_ |
Ll-r,,
--'>
:>
JeEsUBIAI
u {org fu.gef
ln
-)
-l-q,hf.\---- V -Alererurs
's080
-tw-Otd neC (ZSOS-qlp-946) suo4senb fue e,req nof 3r eur il?c ol aleltseq l.uop eseeld
'$e,u l# 8uyp11nq 'a1crr3 peeqsuol'I ggt 1u rue6,{sgoor -rno Eurpe.6dn
go ssacord eql qI^r peecord ol 'clq'sJolcerpo3 8ugoog JJJ pazuorym a^eq I
:uJacuoJ ifuIAI lI ruorllt\ oJ
,s9I8'oC'I?A
peog aSeporC {mog g,
Ir?AJo u \oJ
SOOZ.ZI IIJdV
/-\(4J
a <1v,
/t .l q
()"
I r
-g v
7 <J
\J-"
0
4 q q7
?o
i q
h
4 I
j
I
7 t
a d
I
\r
a q,q
-t l,-/
t
r/)
AJ -r-r a
C,
rc
a q
q
=F r
t I
4 L)
{
a
fi
6
--l
q
{
fl
I
d
h
J
-f,+
q
c
a
I
{-
u4 frtq t, /*b
,-m Design Review Board
ACTION FORM
Deparb'nent of Community Development
75 South Frontage Road, Vail, Colorado 81657
tel: 970.479.2139 fax: 970.479.2452
web: www.ci.vail,co,us
Project Name: TREETOPS CONDOIfiI{IUIiS RE-ROOF DRB Number: DR8050212
Project Description:
TO ADD LAMARTTE SLATE (TAMCO) TO 4 SLOPED SECIIONS OF ROOF ON TOp OF TREE TOPS
CONDOMINIUMS. ALSO ADD WHITE GUTTERS AND FACIA AND HEATTAPE,
Pafticipants:
owNER TREETOPS CONDOMINTUM ASSOC O5/20/2OO5
o/o GREAT WEST MGMT & REALTY CO
3201 S TAMAMC 200
DENVER
co 80231
APPUCANT TCC CONTMCTORS, INC. 05l20l2OOS Phone: 970-328-2340
P.O. BOX 2123
EAGLE
co 81631
License: 540-8
CONTRACTOR TCC CONTMCTORS, INC. 05l20l2OOS Phone: 970-328-2340
P.O. BOX 2123
EAGLE
co 81631
License: 540-8
Project Address: 450 UONSHEAD CR VAIL Location:
TREETOPS CONDO WEST
Legal Descrlption: Lot: 6 Block Subdivisionr Vail Lionshead Filing 1
Parcel Number: 2101-064-0403-1
Comments: SeeConditions
BOARD/STAFF ACnOil
Motion By: Peter Dunning Action: APPROVED
Second Ey: Sherry Dorward
Vote: 4-0-0 DateofApproval: 06/01/2005
CondiUons;
Cond:8
(PLAN): No changes to these plans may be made without the written consent of Town of
Vail staff and/or the appropriate review committee(s).
Cond: 0
(PLAN): DRB approval does not constitute a permit for building. Please consult with
Town of Vail Building personnel prior to construction activities.
Cond; 201
DRB approval shall not become valid for 20 days following the date of approval.
Cond: 202
Approval of this project shall lapse and become void one (1) year following the date
of final approval, unless a building permit is issued and construction is commenced
and is diligently pursued toward completion.
Planner: Warren Campbell DRB Fee Paid: $250.00
ffi ^#
i ::"1;HHirflH"H$:Jo
u c5 o /' s
IOt4NNTIitry "'lji:!i;Tr,:5,1T'.aY1!iliTSlio!|u"
web: www.vailgov.com
General Information:
All projects requiring design review must receive approval prior to submitting a building permit application. please
refer to the submittal requiremenb for the particular approval that is requested. An application ior Design Review
cannot be accepted until all required information is received by the Community Development Department. The project may also need to be reviewed by the Town Council and/or the Planning and Environmental Commission.
Design review approval lapses unless a building permit is issued and construction commences within
one year of the approval.
165'? phone:
Description ofthe Request: I I
0
Location of the Proposal= tott kf Block:_ Subdivision:LocaEron ot tne Proposat: Lot: ,kf Btock:_ tu66;u;r1on' V f+4-t+o+J|<4-€r{d,-_E*ls-ft I _ !l
physicat Address: + 5a Li noo- kc'* d c ir<-l < d lD I
Parcel No.: Ato f O Lt o =\ (Contact Eagle Co. Assessor at 970-328-8640 for parcel no.) I-. --
*o
lrFf Zoning: W
Name(s) of O*n"r(r) f,.,-
\,MaitinsAddress: .fgO Lio ruShe"+J LVc[e
Owner(s) Signature(s):
Name of Applicant: '-l-?- C R o o€; ^-, - C.o d {fnr-,Jsrr S C";e ;;.--- t ;p
E-mail Addrer",
-Fax.
t
l
TypeofReviewand Fee: I V ! Signs $50 Plus g1.00 per square foot of total sign area. l-.E Conceptual Review No Fee E
D New Construction g650 Construction of a new building or demo/rebuild. I I A A!)thon $300 An addition where square footage is added to any residential or
_/ commercial building (includes 250 additions & interior conversions). 7 -lX' Minor Alteration $250 Minor changes to buildings and site improvements, such as,(multi-family/commercial) re-roofing, painting, window additions, landscaping, fences and
D Minor Arteration $20 ;tf;?:fl"ff1l.,:tiuitdinss and site improvements, such as,(single-family/duplex) re-roofing, painting, window additions, landscaping, fences and
retaining walls, etc.! Changes to Approved Plans $20 Revisions to plans already approved by Planning Staff or the Design
Review Board.! Separation Request No Fee
Phoner g7o - ? ze - ?-=IB il:
For Office Use Onlv:
Fee Paid: ./'CheckNo.: / ay:
oate: C- ca4 f
{rk( -(J L. 54-(sJ
I
-t :"'* q
..1.r' ,',,.... r,'i.
e : f',r!*i.
'si
,i ,.:l- \
"f,i "'.ff
{'
,{?'#
-
!9
h
t
April12,20O5
Townof Vail
75 SouthFrontageRoad
Vail, Co.81657
To Whom It May Concern:
I have authorized TCC Roofing Contractors, Inc. to proceed with the process of
upgrading our roof system at 450 Lionshead Circle, building #l west.
Please don't hesitate to call me if you have any questions. (970-476-6982) Cell (970471-
0805.
Sincerely,f\
-.S-xxr €*-
JeffryBrown
Manager
description)
JOINT PROPERTY OWNER
WRITTEN APPROVAL LETTER
I, (print name; JeFF B-o.^r'"r /hr.4
" a jointownerof propefi rocated at (address/regal
provide this letter as written approval of the plans aateA 7/>a/ O+- which have
been submitted to the Town of Vail Community Development Department for the proposed improvements
to be completed at the address noted above. I understand that the proposed improvements include:
I fufther understand that minor modifications may be made to the plans over the course of the review
process to ensure compliance with the Town's applicable codes and regulations,
tlr,l"n
(Date)
Page 2 of I3lI2l02lO4
Buildinq Materials
PROPOSED MATERIALS
TVoe of Material Color
Roof
, Siding
Other Wall Materials
Fascia
Somts
Windows
Window Trim
Doors
Door Trim
Hand or Deck Rails
Flues
Flashing
Chimneys
Trash Enclosures
Greenhouses
Retaining Walls
Exterior Lighting
Other G.*ter-S H
Notes:
Please Specify the manufacturer's name, the color name and number and attach a color chip.
Page 6 of L3/12102104
3 r a,-,: r)
Proposed surface drainage on and off-site.
Location of landscaped areas.
Location of limits of disturbance fencing
Location of all required parking spaces
Snow storage areas.
Proposed dumpster location and detail of dumpster enclosure.
Retaining walls with proposed elevations at top and bottom of walls. A detailed cross-section and
elevation drawings shall be provided on the plan or separate sheet. Stamped engineering
drawings are required for walls between 4' and 6'feet in height.
Delineate areas to be phased and appropriate timing, if applicable
Landscape Plan:
Scale of 1" = 20'or larger
Landscape plan must be drawn at the same scale as the site plan.
Location of existing trees, 4" diameter or larger. Indicate trees to remain, to be relocated
(including new location), and to be removed, Large stands of trees may be shown (as bubble) if
the strand is not being affected by the proposed improvements and grading.
Indicate all existing ground cover and shrubs.
Detailed legend, listing the type and size (caliper for deciduous trees, height for conifers, gallon
size for shrubs and height for foundation shrubs) of all the existing and proposed plant material
including ground cover.
Delineate critical root zones for existing trees in close proximity to site grading and construction.
Indicate the location of all proposed plantings.
The location and type of existing and proposed watering systems to be employed in caring for
plant material following its installation.
Existing and proposed contour lines. Retaining walls shall be included with the top of wall and
the bottom of wall elevations noted.
Lighting Plan:
Indicate type, location and number of fixtures.
Include height above grade, lumens output, luminous area
Attach a cut sheet for each proposed fixture.
REPAINT PROPOSALS
For all proposals to repaint existing buildings, the following supplemental information is required:
Color chip or color sample including the manufacturer name and color number(s)
Architectural elevation drawings which clearly indicate the location of proposed colors (ie. siding,
stucco, window trim, doors, fascia, soffiits, etc,)
a
a
a
a
a
a
a
a
a
o
a
a
a
a
I
Page 5 of t3ltzllzl$4
s
)0
-
' ,E
l'
I
I
I {.
(tl
o c
{I
m l-
nt
>J o
-)
ul
c\
r
Lr
ep
ll
I o
d7'
\v
6o 9f
E,*f-
(A t, F , I(^u( e- 5-Ldf r
a.v g-
$ *\i
4$f
;V
illf
?$F
\
$l+
V
b
F
a T 6
F
F
I
F
r q
D
I
F5
q
)
b
F I
r
h
E
o G +,r
tr b
q$
'a. ':
.flt$
.F --.,1,-;w'
t 4:ltt i
u !.,
C +
rb
t
/-)t
%
b .1
(
I
F q
1
6
I
I (
a r vl
P
tA
e
LP
rc
P
a a>
(-c
K>q
r
"a
fv P
V,e,
p F)Y
j APPUCATIOCLL NOT BE ACCEPTED IF INCOMPLilR
NVNOPVAIL
75 S. Frontage Rd.
Vail, Colorado 81657
*****************J.rr********************FOR OFFICE USE ONLY**,r\*********************************
\F , \)-F\ \ --
I
Building Permit #:
Alarm Permit #:
FI
Commercial & Residential Fire Alarm shop drawings are required at time of ) application submittal and must include information listed on the app[cauon suDmtttat and must lnclude informataon
?"1 nage orgis ffm. Applical[on will not be 4ccept out this ffis#,"ffi-ru
COMPLETE VALUATIONS FOR ALARM PERMIT (Labor & Materiats) c , ..
FlreAiarm: sffiio / JJ,,oao lrof e.-.8\K\
Tu.-^.,-,\-op-a
Fire Alarm Contractor;Town of Vail Req. No.:Contact and Phone #'s: q 16 .{ 7l o(eK)
, tt ,.-1 ft
' Jun t I ;^ - " Fornet: r k u^t e r-
,-,
Contact Assessorc Offrce at 970-328-8640 or visit www.for Parcel #
Parcel # (Required if no bldg. Permit # is provided above) 2bloblo+ 03 i
Job Name: 6ee fops (nndo,s Job Address: +rt e . bo*s Aeal &a._ hr I
Legal Description Lot:Block:Filing:Subdivision;
owners N.fr€i',-. -tt ft t.-,J,. ro ll Addressr ,r ,, o, E 1-,-*-,r,,+.r (,<:/p ll Phone: t/.7 r - ,/ ) / - c.) {/a /;
Engineer:P...v Mr*fr",,J5 llirLllooo'"ttti-"n,, r,t,/: -.,,,, .avt 1 | llPhoneJl7 - azt ' (l-t r
Detailed Location of work: (i.e., floor, unit #, bldg, #) iJ-t""r' /.'ttt 1 ?(, J <>
.4 ftirU Jtrtrcfc.rc-
Detailed descriotion of work:-/r /1 . .
Katco - Y'l 6+FA suste"n- urlotl
WorkClass: New( ) Addition( ) Remodel( ) Repair( ) Retro-fit(X) Other( )
Typeof Bldg.: Single-family( ) Two-family( ) Multi-family({) Commercial ( ) Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: o!?No. of Accommodation Units in this building: g/
Does a Fire Alarm Exist: Yes (X) No ( )Does a Fire Sprinkler System Exist: Yes (y) No ( )
F:/everyone/forms/alrmperm
RICD MAY 2I 2004 Sz/
t
a
t
,[
c .t,
TOWN OF VAIL FIRE DEPARTMENT PROCESS
FOR COMMERCIAL & RESIDENTIAL FIREAIARM SYSTEMS
Commercial and Residential Fire Alarm shop drawing requirements at time of
submittal must include the following:
-'
J/
-
1,."
L....
I/
V'
t/
A Colorado Registered Engineer's stamp.
Device locations on reflected ceiling plans.
Typical device wiring diagrams.
Battery calculations.
A list of specific device model numbers.
Equipment cut sheets of each type of device.
The number of each type of device.
Information indicating the specific zones.
Circuit diagrams.
Point to point wiring diagram.
Wiring type, size, and number of conductors.
The source of AC power circuits.
Fire alarm panel locations.
Knox Box location.
Information indicating monitoring method and monitoring
agency.
Information regarding property managers and contact numbers.
Owner's primary residence location and contact numbers.
Instructions for fire alarm system operations and any pertinent
code numbers for proper operations.
This check list has been provided to ensure that our review process may be
handled in a timely manner.
I have read and understand the above listed submittal requirements:
Project name: frce fops C'"lo'r
Contractor Signature:
Date Signed:
TOWN OF VAIL FIRE DEPARTMENT GUIDELINES
FOR PREVENTING NON-EMERGENCY FIRE ALARMS
In order to prevent a non-emergency response from the Vail Fire
Depaftment
Suppression crews to the construction location you may be working on we
as! that you pedorm the following tasks:
424 Determine what kind of fire alarm system exists within the ' structure you are working in with the owner or the manager of
/ the property involved or by contacting the Vail Fire Department.
/ ,.-1',
a) Determine with the owner or manager of the property, which
T alarm company seruices the systemfor them.-/.P -J2Ll Become familiar with the different components that are
associated with the fire atarm system ahd how they operate
.1 ?-, before the DEMO begins.-.{a(&' Never paint a smoke detector, thermal d€tector, o_r any ot[re-r-
component of the fire alarm system, and never paint a sprinkler
t ^ head'4r1 (D ^ For small projects bag detector within the area you will be
working in before you start' and remove the bags after work is
.a done for the day.{<R &\ For larger projects, please contact the Vail Fire Depaftment so
that we can work with you in determining what needs to be done
to alter or "Zone Out" specific areas of the alarm system for the
structure.
Please contact the Town of Vail Fire Marshal, Mike McGee at479-2135 or the
Town of Vail Fire Prevention Officer, Mike Vaughn at 479'2462.
I have read and understand the above guidelines.
Project Name:
Contractor Signature:
Date Signed:
lr"t * INFoRT\rATron ."rul
VAIL FIR.E & EMERGENCY SERVICES
BIJILDING INFORI\,IATION :
; -4 ..',Buildinr narne: lr€€ /or>.5 Condaf
Streetaddress&phone *: 15b €. Con-sAza/. Cr./e
-11 Knor bor location: otfsidg*t* door
Alarm panel location:
Alarm silence & reset
RPS': NAMES & PHOIIIE I\IIIMBERS (work & home):
Owner:
- ff.st en"tcanr"-
codes: {uLf0 C,tos
A Main location: 6dwer . llA*s
Property manager:
Property maintenance manager, 7eff 6nnrtr.
Alarm senice comp rry: 4l'- 6LsT €,lectr,L
BIIILDING UTILITIES:
Gas:
Other locations:
Dlectric:
Main location:
Sub-panel locations:
Water:
Main valve location: 6.qe+r,Nk tA+i li{-y Pr",^
Main fire valve location:
Secondary water valve tocations: &cL {loo(.
z1..-\At\'r-'.z\t'$1"/
nwo-rwnffiY
HOW DID WE RATE WTTH YOU?
Town of Vail Survey
Community Development Department Russell Fonest, Director,
(970) 47s-2139
Check allthat applies.
1. Which Deparfnent(s) did you contact?
Building _ Environmental_ Housing_ Admin _Planninq DRB PEC
2. Was your initial contact with our staff immediate_ dow _or l
no one available ?
3. lf you were required to wait how long was it before you were
heiped?
4. Was your project reviewed on a timely basis? Yes / No
lf no, why not?
5. Was this your first time to file a DRB app- PEC app-
Bldg Permit .-. N/A
6. Please rate the performance of the stafi person who assisted you:
54321Name:
(knowledge; responsiveness, availability)
7. Overall effectiveness of the Front Service Counter. 5 4 3 2 1
8. What is the best time of day for you to use the Front Service
Counter?
9. Any comments you have which would allow us to beter serve you
next f,me?
Thank you for taking the time to complete this survey. We are
committed b improving our seMce.
Parcel Multipl€ Search Results http: //eagle-counTon/goodtums/assessor/?arcelMultipl...
County Offcials I County Services I Communiry I Videos Advanced Search I Calendar I Contact I EC Home
Eagle County Assessor/Treasurer
Search Results
Assessor/Treasurer Property Search I Assessor Subset Query I Assessor Sales Search
Legal Description: Subdivision Search
The following parcels were selected, The records are sorted by ParcclNumber. lo display detail information for a selected
parcel, click on the respectlv€ Account umber.
Parcel Number
Physic6l Address
452 E UONSHEAD CIR VAIL
I- poziisa BMNIFF, JUAN CARLOS & BARBAM
p e uor'rsHtao cln vat CONDO: TREETOPS CONDO
UNIT:38
DESC:BLDG A PK SP 14
HOUSEHOLD
FURNISHTNGS 2101-064-04-006
P010192 PETERSON, ALAN E. & MILDRED A.
+li i uor'rsnreo Cin vnrl CONDO: TREETOPS CONDO
UNIT:3A
DESC:BLDG. A PK,SP. 9
HOUSEHOLD
FURNISHINGS 2101-064-04-00s
P001548
452 E LIONSHEAD CIR VAIL
R010825
KEENE Z. SMITH TRUST . JOAN W. SMITH
CONDQ: TREETOPS CONDO
UNIT r 3C
DESC:BLDG B PK SP 20
HOUSEHOLD
FURNISHINGS 2101-064-04-020
SIMPSON TELLURIOE PROPERTIES LLLP
CONDO: TREETOPS CONDO UNIT:1A
DESC;BLDG A PK SP 5 BK-0307 PG-0648
08-22-80 BK-0307 pG-0649 08-22-80
BK-0307 PG-0650 08-22-80 8K-0307
PG-0651 08-22-80 BK-0307 PG-o652
I nooizri
i -- itgifD;;i;i;ii;'
GIBSON, MARViN M. & MARTHA R.A.
i DESC:BLDG A PK SP 4 HOUSEHOLD
I FURNTSHTNGS 2101-064-04-010
E LIONSHEAD CIR VAIL
I of5
52 E LIONSHEAD CIR VAIL
2t070640400!
512s12004 6:16 AM
Parcel Multipld Search Results http://eagle-counfon/Soodtums/assessor/ParcelMultipl...
BK-0388 PG-0447 BK-0388 PG-0448
BK-0388 PG-0449 BK-0388 PG-0450
8K-0388 PG-0451 8r(-0388 PG-0452
BK-0226 PG-0402 WD 11-21-72
R750387
swD 01-01-01 R750388 SWD 01-01-01
R750389 SWD 01-01-01 R750390 SWD
01-01-01 R7s039r SWD 01-01-01
R750392 SWD 01-01-01
CONDO: TREETOPS CONDO
UNIT:18
DESC:BLDG A SK-O335 PG-0377
11-02-81 BK-0319 PG-o563 WD
02- 18-81
52 E LIONSHEAD CIR VAIL
52 E LIONSHEAD CIR VAIL
R009415
52 E LIONSHEAD CR VAIL
210106404004
210106404005
CARGER LTD
CONDOT TREETOPS CONDO UNIT:28
DESC:BLDG A PK SP 15,41 BK.O231
PG-o397 WD 03-31-73 BK-0238
PG-0585
QCD 02-05-75 BK-0247 PG-0655 QCD
06-30-76 BK-0226 pc-0399 03-31-76
BK-0318 PG-0001 01-02-81 BK-0409
PG-0934 03- 18-85 BK-0423 PG-0650
07-23-85 BK-0458 PG-0894 QCD
06-05-86 BK-0458 PG-089s QCD
06-0s-86
PETERSON, ALAN E. & MILDRED A.
PETERSON, ALAN E. & MILDRED A.
CONDO: TREETOPS CONDO UNIT:34
DESC:BLDG A PK SP 9 BK-0228 PG-AZ7I
BK-0470 PG-0972 WD 09-29-87
BK-0471
PG-0531 10-08-87 BK-0226 PG-0400
WD
03-31-76
CONDO: TREETOPS CONDO
UN IT:38
DESC:BLDG A PK SP 14 BK-0222
PG-O737 WD t2-06-77 BK-0226
PG-0403 WD Lr-2t-72 BK-O297
PG-0088 WD t2-27-79 BK-0437
PG-0076 SWD 09-01-85
CONDO: TREETOPS CONDO UNIT:4A
DESC:BLDG A PK SP 3 BK-O261 PG-0513
gK-0243 PG-0777 72-18-75 BK-0222
PG-0634 12-06-71 BK-0252 PG-0053
WD
: 08-22-80 BK-0307 pG-o653 08-22-80
452 E UONSHEAD CIR VAIL
452 E LIONSHEAD CIR VAIL
2of5
452 E UONSHEAD CIR VAIL
5125/2004 6:16 AM
Parcel Multiplb Search Results
452 E LIONSHEAD CIR VAIL
452 E UONSHEAD CIR VAIL
CONDO: TREETOPS CONDO UNIT:48
DESC:BLDG A PK SP 7 BK-0222
PG-0808
BK-0226 PG-0405 BK-0354 PG-0324
01-03-83
210106404008
http://eagle-counUon/goodtums/assessor/ParcelMultipl...
0t-L4-77 BK-0226 PG'039s 03-31-76
HUMPHREY, REBECCA B.
MSURA CORP
CONDO; TREETOPS CONDO UNIT:5A
DESC:BLDG A PK SP 8 BK-0346
PG-0492
09-24-A2 BK-0226 PG-0406 WD
r7-2r-72 BK-0735 PG-o226 QCD
08-11-97 R826582 QCD 03-0s-03
GIBSON, MARVIN M. & MARTHA R.A.
norozss r" '
I ro roo+b+or r
CONDO: TREETOPS CONDO UNIT:6A
DESC:BLDG A PK SP 6 BK-0426
PG-0949
09-30-85 BK-0226 PG-0401 tt-2r-72
R801912 BSD 07-01-02 R801913 BSO
07-01-02 R801915 BSD 07-01-02
R801916 BSD 07-01-02
210106404012
210106404013
OXLEY, THOMAS D. & AMEAUA S.
CONDO: TREETOPS CONDO
UNIT;68
DESC:BLDG A PK SP 1-2 BK-0226
PG-0398 WO tr-24-72 BK-O233
PG-0447 QCD 02-19-74 BK-0262
PG-0094 WD 11-01-77 BK-0357
PG-0315 WD 11-30-82
BARNETT INVESTMENTS LIMTTED
CONOO: TREETOPS CONDO
UNIT:7A
DESC:BLDG A PK SP 13 BK-0225
PG-o397 WD 11-21-72 R710815
WD
08-30-99 R710816 WD 08-30-99
R712444 WD 10-07-99 R712445
WD
10-07-99
CONDO: TREETOPS CONDO
UNIT:1C
DESC:BLDG B PK SP 24
KLEIN, GARY C.
CONDO: TREETOPS CONDO UNIT:1D
DESC:BLDG B PK SP 28 BK-0313
PG-0822 QCD 10-31-80 BK-o375
R00865 5
452 E LIONSHEAD CIR VAIL
R010195
452 E UONSHEAD CIR VAIL
R009565
452 E UONSHEAD CIR VAIL
452 E LIONSHEAD CIR VAIL
210106404014
52 E UONSHEAD C]R VAIL
R008332
50 E LIONSHEAD CIR VAIL
3 of5 512512004 6:16 AM
Parcel $ultiple Search Results
R008333 210106404016
52 E UONSHEAD CIR VAIL
R008334 210106404017
452 E UONSHEAD CIR VAIL
R008344 210106404022
UNIT:1E
KAYUE S.A.
BROWN, EDWARD M.-
CONDO: TREETOPS CONDO
U NIT:2C
DESC:BLDG B PK SP 10 BK-0678
PG-o595 BSD 10-02-95 BK-0680
PG-0575 BSD 10-02-9s
CONDO: TREETOPS CONDO
UN IT:2E
DESC:BLDG B PK SP 27
R00B342 2r0fi6404020
52 E UONSHEAD CIR VAIL I COIIOO: TREETOPS CONDO UNIT:3C
DESC:BLDG B PK SP 20 R752052
. nrn
I 03-14-01 R765262 cWD 07-26-01 I
I
R765263 GWD 07-26-01 l ,''.'
i DESC:BLDG B PK SP 23 BK-o349
I PG-0457 11-19-82 BK-0476 PG-0302
I
BK-0476 PG-0303 BK-0476 PG-0304 l
I BK-0476 PG-0305 BK-0476 PG-0306
; er-o+zo PG-0307 BK-0480 PG-0499 lwD
;
i os-ro-ee BK-o4go Pc-osoo wD l
:03-10-88 BK-0480 PG-0501 WD
los-ro-ss BK-0670 Pc-oeog ecD I
i07-03-95
19,9,9-r '110,1, i:---. 'l*res, g11L
l
EAD cIR VAIL icorrroo: TREETOPS CONDO
iUNIT:3E rl
I oesc;sLoc B pK sp 26 ]
zroroeeo+ozJ-
--:'--- '''-
ba*renrrue o. uennevJCusree
I
EAD CIR VAIL COIOO' rnEnOpS CONDO i
iUNIT:4C
I DESC:BLDG B PK SP 25 BK-0476 |-l
I PG-0297 swo lo-os-s7 I
DESC:BLDG B PK SP 20 R752052
QCD
03-14-01 R765262 GWD 07-26-01
R765263 GWD 07-26-01
R008343 210106404021 j JOHNSON, MTCHAEL - ET AL.
52 E UONSHEAD CIR VAIL CONDO: TREETOpS CONDO UNITT3D
DESC:BLDG B PK SP 23 BK-0349
PG-0457 11-19-82 BK-0476 PG-o302
BK-0476 PG-0303 BK-0476 PG-0304
BK-0476 PG-0305 BK-0476 PG-0306
BK-0476 PG-0307 BK-0480 PG-0499
WD
03-10-88 BK-0480 PG-0500 WD
03- 10-88 BK-0480 PG-0501 WD
03-10-88 BK-0670 PG-0909 QCD
07-03-95
R008344 210106404022 r PHILLIPS, CARLOS & GUADALUPE M. CALZ
452 E UONSHEAD cIR VAIL icorrroo: TREETOPS CONDO CONDO: TREETOPS CONDO
UN IT:3E
DESC;BLDG B PK 5P 26
210106404023 : CATHERINE D. TIERNEY TRUSTEE
452 E UONSHEAD CIRVAIL CONDO: TREETOpS CONDO
UNIT:4C
DESC:BLDG B PK SP 25 BK-0476
PG-0297 SWD 10-05-87
http ://eagle-coun$r/goodturns/assessor/ParcelMultipl...
PG-o424 WD 12-22-83 BK-0402
PG-0868
QCD 12-18-84 R646681 QCD 01-22-98
CONDO: TREETOPS CONDO
DESCTBLOG B PK SP 77 BK-0449
PG-0419 WD 6-24-86
52 E UONSHEAD CIR VAIL
4of5 5125/2004 6:16 AM
Parcel $+ltiple Search Results
52 E UONSHEAD CIR VAIL
ROOB34B
CONDO: TREETOPS CONDO UNIT:4D
DESC:BLDG B PK SP 11 BK-0349
PG-0456 11-19-82 BK-0476 PG-0298
06-04-87 BK-0475 PG-0299
06-04-87
BK-0476 PG-0300 06-04-87 BK-0517
PG-o131 QCD 10-25-89 BK-0517
PG-0132 QCD 10-25-89
r 210106404025 I ToMARES, STEVEN B. &AARON -JT
452 E LIONSHEAD CIR VAIL CONDO: TREETOPS CONDO
U N IT:5D
DESC;BLDG B PK SP 22
R008353
452 E LIONSHEAD CIR VAIL
R040415
50 E LIONSHEAD CIR VAIL
50 E UONSHEAD CIR VAIL
210106404028 ICAZA, ANTONIO CORTINA
CONDO: TREFTOPS CONDO
UN IT:5 E
DESC:BLDG B PK SP 19
WALLACE ENTERPRISES INC
CONDO: TREETOPS CONDO
UNIT:X
BK-0607 PG-0204 DEC 04-23-93
BK-0607 PG-0205 MAP 04-23-93
TREETOPS CONDOMINIUM ASSOC
CONDO: TREEToPS CONDO
UN TT:Y
BK-0607 PG-0204 DEC 04-23-93
BK-0607 PG-0205 MAP 04-23-93
R692205 DEC 04-09-99
35 Record(s) Dlsplayed,
http ://eagle-counf om/Soodtums/assessor/ParcelMultipl...
CONDO: TREETOPS CONDO
U N IT:4E
DESC:BLDG B PK SP 25 BK.O3O9
PG-0630 09- 17-80
PILLSBURY, CHRISTINE B. & EDMUND P., III
CONDO: TREETOPS CONDO UNIT:5C
DESC:BLDG B ASSIGNED PK BK-0226
PG-0061 BK-0550 PG-0121 QCD
11-9-90
R819066 QCD 12-18-02
452 E LIONSHEAD CTR VAIL
210106404026
452 E LIONSHEAD CIR VAIL
Top of Page
Assessor Database Searci] Options I Treasurer Database Search Options
Contact us by phone: (970)328-8640, in Colorado (800)225-6136
By mail: Eagle County Assessor, 500 Eroadway, PO BOX 449, Eaqle, CO 81631
Or by email
The Eagle County Assessor and Treasurer's Offices make every effort to collect and maintain accurate data. However, Good Turns Software
and the Eagle County Assessor and Treasurer's Offices are unable to warrant any of the information herein contained.
Copyright O 2001 Good Turns Software. All Riqhts Reserved.
Database & Web Design by Good Turns Software.
5 of 5 512512004 6:16 AM
lErllllilghro nodel $2m.
tddrusoble tlnllonn Coilrd Syltcm ;
Ihe IntelliKnighl System is the eosy
woy to moke fte mosl of fire alorm
technology.
IntelliKnight is the first fire alarm system to provide you with the revolutionary value and performance
of addressable sensing technology combined with exclusive, built-in digital communication, distributed
intelligent power, a modular design and an expanded, easy to use interface. Powerful features such
as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight"
For more information about the IntelliKnight system, or to locate your nearest source, please call
1-800-446-6444, or in Minnesota, call 763-493-6435.
Dmlpllort
The IntelliKnight 582OXL performs drift
compensation and calibration checks
on each of the sensors in the system.
The basic IntelliKnight 5820XL system
can be expanded by adding modules
such as the Model 5860 Remote
Annunciator, Model 5815XL Signalling
Line Circuit Exoander the Model 5824
Serial/Parallel Intedace (for printing
system reports), and the 5895X-
Intelligent Power Module. The Model
5820XL also features a powerful built-in
dual line fire communicator that allows
for reporting of all system activity to a
remote monitoring location.
FOffi . Up to 508 addressable points.. Uses standard wire-no shielded or
twisted pair required.. BuilLin digital communicator.. Central station reporting by Point or
Supports Sounder Bases.
by Zone.
Built-in synchronization tor
appliances from AMSECO,Gentex@,
Faraday, and Wheelock@
Supports Class B (Style 4) and
Class A (Style 6) configuration for
SLC, SBUS, and Flexput circuits.
Distributed, intelligent power.
Drift comoensation.
FlexputrM l/O circuits.
Eight pre-programmed output
cadences, (including ANSI-3.4 1 ),
and 4 programmable outputs.
Built-in annuncialor with 80-
character LCD display.
RS-485 bus provides communication
to system accessories.
Buillin RS-232 interface for
programming via PC.
Built-in Form C trouble relay raled at
2.5 amos al 24 VDC.
Two builfin Form C programmable
relays rated at 2.5 amps at 24 VDC.
Primary AC: 120 VRMS at 50 / 60 hz,
2.54
Total Accessory Load: 5A at 24 VDC
5 amps at 24 VDC of power-limited
notification power
Standby Cunent: 140 mA
Alarm Current: 260 mA
Flexput'* Circuits
Six programmable circuits which can
be programmed individually as:
Notification circuits: 3 amps of
power-llmited power per circuit at 24
VDC.
Auxiliary power circuits: 3 amps of
power-limited power per circuit at 24
VDC,
Initiation Circuits: '100 mA of power
limited power per circuits at 24 VDC.
fedorbl Seodnonoc
Flush Mount
Dimensions:
14-112'W x 24-314'H x 3-7l8"D
(36.8Wx62.9Hx9.8Dcm)
Overall Dimensions:
16-1/8'W x 26-3l8'H x 4-118'D
(40.6Wx67Hx11.8Dcm)
Weight: 28 lbs. (12.8 kg)
Color: Red
Telephone Requirements:
FCC Part 15 and Part 68 approved
Type of Jack: RJ31X (two required)
-Central Station
-Remote Sagnalling
-Local Protective
Signalling System
-Auxiliary Protected
Premises Unit
-Water Deluge
Releasing Service
7165-0559: 135
429-92-E Vol. 9
approveo
SILENT
KNIGHT
lpptoulh
UL Listing
NFPA 72
CFSM:
MEA
FM
lftlllkrbht todel $2m. fidrorstdo Fln lloru
Coilrol knel
lndlffir Ugh$
GENERAL ALARM (Red) - On for
alarm
SUPERVISORY (Yellow) - On
when a supervisory condition
extsls.
SYSTEM TROUBLE (Yellow) - On
when a trouble condition exists.
SYSTEM SILENCED (Yellow) - On
when an alarm, trouble or
supervisory condition has been
silenced but not yet cleared.
SYSTEM POWER (Green) - On
when power systems are
normal;flashes for AC or DC
failure.
enclosure is required for batteries dialing. The communicator is
$|erlDdlollor
The IntelliKnight Model 5820X1
control oanel has one built-in
Signalling Line Circuit (SLC) which
supports 127 devices. Three
additional looos can be added
using the 581sXL SLC expanders
to increase overall capacity to 508
oevtces.
The Model 5820X1's SLC loops
support multiple device types:. Addressable photoelectric smoke
detector . Addressable ionization smoke
detector . Addressable heat sensor . Addressable duct smoke
detector . Contact module . Relay output module . Addressable notification module
The following advanced sensor
capabilities are available using the
IntelliKnight Model 5820X1:. Automatic drift compensation . Maintenance alert . Builtin sensor test to comply
with NFPA 72 calibration testing
reouirements
The lntelliKnight 5820X1 features a
5 amp power supply and maximum
battery charging capacity of 33
amo hours. An additional cabinet
in excess of 17 amp hours.
Flexpul'" circuits on the Model
5820XL control can be individually
programmed to function as notifi-
cation circuits, auxiliary power
outputs, or initiation circuits that
support both 2- and 4-wire smoke
detectors.
The IntelliKnight system operates
on non-twisted, unshielded cable
when wired in comoliance with
standard wiring practices as called
out in the National Electric Code
760 specifications for power-limited
fire protective signalling cables. No
special wiring is required.
The Model 5820XL provides seven
preset notifl cation cadence patterns
including ANSI 3.41 and four user
programmable selections for fire
alarm notification.
Two programmable general
purpose Form C relay outputs are
provided on the Model 5820XL
FACP.
Additionally, the IntelliKnight
system features a built-in walk test
and auto-programming. lts
innovative, dead-front cabinet
design allows for flush or surface
mounting. System maintenance is
easy to perform.
ldll.lr DlglhlConrr|otui
The IntelliKnight Model 5820X1
features a buillin UL listed digital
communicator for remote reporting
of system activity and system
programming. The communicator
has the ability to seize two
telephone lines to report alarms
and troubles to a monitoring facility.
The communicator supervises two
phone lines and will activate a
trouble signal if a line failure is
sustained for more than 45
seconds. Other communication
features include: retry if communi-
cation fails, two phone number
capability, download phone number
capability and touchtone or rotary
compatible with SIA and Ademco
Contact lD. The format is
selectable by account number.
lfs hhft.r
The IntelliKnight's built-in
annunciator with 80 character LCD
display and large easyto-use
tactile touchpad can be used for
system operation, programming
and maintenance. lt has five LEDs
for alarm, supervisory, system
trouble, system silenced and
system power. System operations
include silencing alarms and
troubles, resetting alarms and the
display of alarm troubles and
memory. The system's non-volatile
event history buffer stores 1000
events for viewing from the built-in
or remote annunciator. System
operation can be initiated with a
mechanical firefighter's key or a
valid 4- to 7-digit operator's code.
The IntelliKnight system offers
several options to simplify and
speed up programming. The
JumpstartrM feature minimizes
programming required to start a
new system. The built-in keypad
and the 5860 Remote Annunciator
give on-site access to all
programming. You can also
program remotely using the
Windows'" Download Software.
Indlltrbh kftl St20L lddruble
Flnllon Coilld Punel
9g)0
lntelliKnight 5820X1
Addressable Fire Ala rm System
9500
5860
5a95XL
I
58t5XL
6
FlexputrM
6
Flexput'M
sosoct Eo so500{l{M so505-6n8 s0505{ta
lFt oEl <
F- Kp-:"
sostF.Ars sos0s-6a3 so505.AHs
SD506-ADH SD5o&il$t SOSOOTARM SO500{IM I
R.r., !&r ! nr h,'.1, I Ho6c i
I
I
I
I
I
I use tt'. saao tn *,'t,ot ,rn t" o i- - ..1 I arBS3Reiay Intedaor lvJodr.rtes i , _,
:
l:
.j!!. ::,.r/ 1i!, .. .. .a -:v
S605{DNR SD500'S
H.d'a^.{y
5865.4 or 3665J
588:!
lfrUtdgh$sorlrorb
Compatible Devices
IntelliKnighl's devices feature a low
profile design and EEprom addressing
EEprom addressing prevents water
intrusion problems via the back of the
sensor and eliminates mechanical
failures related to decade swttches.
Model SD505-APS
Addressable photoelectric smoke
detector.
Model SD505-AlS
Addressable ionization smoke detector.
Model SD505-AHS
Addressable heat sensor
Model SD505-6AB
Six inch base designed for use with
detector head models SD505-APS.
SD505-AlS and SD505-AHS.
Model SD5054AB
Four inch base designed for use with
detector head models SD505-APS.
SD505-AlS and SD50s-AHS.
Model SD500-A|M
Dry Contact Input Module. Designed to
used with normally open dry contacts.
Mounts in a 4 inch square electrical
box. lt features an indicator LED to
show alarm status and a coverplate.
Model SD500-MlM
Mini Dry Contact lnput Module. A
miniature version of the addressable
input module which is designed to be
used with pull stations and other
normally open dry contact inputs where
a smaller srze is desired.
Model SD500-ANM
Addressable Notifi cation Module
providing a single Class A or Class B
notification circuit on the SLC.
Model SD500-ARM
Addressable Relay Module. Features 2
Form C output relays, designed to
mount on a 4 inch souare electrical
box. Provides indicator LED to show
outout status and comes with a
coverplate.
Model SD505-ADH
Duct Housing. Detects smoke in HVAC
ducts.
Model SD505.ADHR
Duct detector base with relay. Provides
form C alarm contact. For use with
SD505-APS and AIS sensors.
Compatible with SD505-DTS remote
test switch.
Model SD505-DTS
Remote test switch. Used with SD505-
ADHR. Provides remote key operated
test function and annunciation of
detector alarm.
Model SD505-6SB
Six-inch sounder base. Operates in
single and multi-station modes and/or
as a syslem sounder. Used with
existing sensor and base. Requires 2
additional wires for oower,
Model SD505-6lB
Six-inch isolator base. Used with
existing base and the SD505-APS,
AlS, and AHS sensors. Provides
isolation for style 7 circuits.
Model SD505-6RB
Six-inch relay base. Used with existing
sensor and base. Provides one Form C
contact.
Model SD500-SDM
Two-wire detector inout module. Allows
for the connection of conventional 2-
wire detectors on the SLC loop.
Requires two additional wires fof
oower.
Model SD500-LlM
Loop lsolator Module. Provides
isolation for style 7 circuits,
Model SD500-LED
An Addressable LED driver module that
connects to the sLc loop and is
capable of driving 80 LEDs. Up to 40
SD500-LED modules can be used SLC
loop with a maximum or 100 SD500-
LED modules per system.
Model SD500-PS
Addressable Pull Station
S-BUS Accessories
5860 Remote Fire
Annunciator
The 5860 features the
same 80 character
backlit LCD display
keypad and firefighter's
kevswitch as the 5820.
The system can be fully programmed
and operated from any remote
annunctator.
581SXL Signal Line Circuit Expander
The SLC expander is used to add more
addressable devices to the IntelliKnight
system. The 5820XL can suppod three
5815X1s. Each 5815X1 can suDoort
127 devices.
5895XL Intelligent Power Module
Adds 5 amps of power, 6 FlexputrM l/O
circuits and 2 Form C relay circuits to
an IntelliKnight system.
5880 LED/IO Module
Features 40 LED outputs, 8 normally
open dry contact inputs and one piezo
output.
5865-3 and 58654
Remote LED Annunciator
Features 30 Programmable LEDs (15
red and 15 yellow) outputs and piezo
sounder- The 58654 adds a silence
and reset switch to the package.
5883 Relay Board
Features 10 General purpose Form C
relays Used with 5880 module.
5824 Serial/Parallel Gateway Module
Has one parallel and one RS-232 serial
port for connecting any standard IBM-
compatible printer to the IntelliKnight
system. Interfaces with building control
system.
5496 lntelligent Power Module
The Model 5496 is a 6 amp.notification
power expander that provides four
additional power-limrted notifi cation
appliance circuit outputs.
SKSS Silent Knight Software Suite
5660 Up Down Load Software
User-friendly, WindowsTM software for
remote programming of the IntelliKnight
panel using a PC.
5670 Facility Management Software
Powerful end-user software allows
viewing of detector status and evenl
history via modem or direct connection.The following items listed are devices
that connected to the IntelliKnight's RS-
485 Bus
SILENT
KNIGHT
7550 Meridian Circle, Maple Grove. MN 55369-4927
8OO-446-€i444 or in Minnesota 763-493-6435
FAX: 763-493-6475
World Wide Web: http://wwwsilentknight.com
MADE IN AMERICA
FORM# 350210, Rev. 04/02
Copyright O 2002 Silent Knight
IntelliKnight is a Registered Trademark of Silent Knight
Flexput is a Trademark of Silent Knight
RemotenXH.L:,t"? M
Bring the power to control IntelliKnighto
to every area within your facility.
Now you can operate and program your IntelliKnight system from up to 8 locations throughout your facility. The
Model 5860 Remote Annunciator provides the same advanced, easy-to-use interface found on the lntelliKnight
panel's built-in annunciator. The 8O-character display and ergonomically designed keypad allow for simple and
error-free system operation. All operations-including reset, silence, detector status checking, fire drill, and
programming-are identical.
Access to the system is through a firefighter's key or an access code. For security, a special installation code is
needed for programming functions.
The 5860 connects to the IntelliKnight panel via the RS485 system bus. Wire runs can be up to 6000 feet from
the oanel.
Model 5860
Remote Annunciator
The 5860 is designed to look and
operate exactly the same as the
IntelliKnight built-in annunciator.
Features include an 80-character
backlit LCD providing easyto-
understand system messages. The
annunciator is ergonomically
designed with over-sized buttons
for the most frequently used
features, like Reset and Silence.
In addition to status messages
displayed on the LCD, there are
five LEDs for alarm, supervisory,
trouble, silence, and AC power
status.
The annunciator is available in gray
to match virtually any decor and red
for applications where the
annunciator must stand out. The
annunciator enclosure can be
surface or flush mounted. A trim
ring kit is available for surface
mounting.
Operation
When the system is normal and
receiving AC powel the power LED
is lit and all other LEDs are off.
Other LEDs turn on as the
conditions occur.
Users identify themselves to the
control panel by entering a code on
the annunciator or by turning the
firefighter's key. When a user
presses a button, the annunciator
piezo beeps and the LCD prompts
the user to enter a code or other
relevant information.
Multiple users can work at different
annunciators simultaneously
without affecting each other.
Features
80-character display
Tactile/aud ible feed back
Accepts user codes or
firefighter's key
RS-485 interface to panel
Can be flush- or surface-
mounted. Trim ring available for
surface-mounting.
Operation and appearance
identical to on-board annunciator
Supports simultaneous use by
multiple users
UL listed. comolies with NFPA 72
CSFM Approved
MEA Listed
FM Approved
lI:l:3; ,i:i3::i; o I
5860 Remote Annunciator
Specifications
Operating Voltage: 24 VDC
Standby Current:
Alarm Current:
20 mA
25 mA
Max. per system:
Ambient Temp€rature: 32oF to 120oF
(ooc to 49oc)
Mounting:Surface or flush
Wiring Distanco from
lntslliKnight panel: Up to 6,000 fset
Dimensions:Height: 7-318"
Width: 9-1/8"
Oepth: 1-112"
Lt. gray (5860)
Red (s860R)
SILENT
KNIGHT
Model 5860
Remote Annunciator
Engineeri ng Specifications
The main control must have a built-in annunciator and must support up to eight remote annunciators. Remote
annunciators shall have the same control and display layout so as to match the appearance of the built-in
annunciator. Remote annunciators shall be available in two colors, red or light gray.
Remote annunciators shall have identical functionality and operation as the built-in annunciator. All annunciators
must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System
Trouble, System Silence, and System Power.
All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a
travel of .040 inches. No membrane style buttons will be permissible.
The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator
keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the
operating system programming to authorized individuals. The control panel must allow all annunciators to
accommodate multiple user input simultaneously.
5860 Block Diagram
Up 10 6000 trst frsn psn€l
q*Fm ,r , .c .-i${A trg ul
qFrb
UP lo 8 devtes per Syslern
E{ SILENT
ll\l KNTGHT
D,o
7550 Meridian Circle. Maole Grove. MN 553694927
8OO{46.6444 or in Minnesota 763-493-6435
FAX: 763-493-6475
World Wide Web: httoJlwww.silentknaqht.com
MADE II{ ATIERICA
FORM# 350224, Rev. 0'l/01
Copyright @ 2001 Silent Knighl
Model 5895XL
Intelligent Power
Module
The inlelligent woy to distribute powel
ft roughout your instollotion
With 5.0 amps of output power, six programmable FlexputrM l/O circuits, and two Form C relay
contacts, the Model 5895XL Intelligent Power Module allows you to greatly enhance the capabilities of
an IntelliKnight system, distributing power where needed throughout a facility.
5895XL modules connect via the RS 485 system bus. Up to eight 5895X1 modules can be used per
IntelliKnight system. Each 5895XL has its own optically isolated RS 485 bus to which other modules,
such as 5860 remote annunciators and 5824 printer interface modules, can be connected. You can
also connect 581sXL SLC expansion modules, adding flexibility and wiring distance. Each 5895XL
supports its own backup batteries and monitors the AC power.
Model 5895XL
Intelligent Power Module
The Model 5895XL adds 5.0 amos
of powet six Flexput l/O circuits,
and two Form C relay circuits to an
IntelliKnight installation. The
5895X1 is optically isolated
providing ground loop isolation and
transient protection. The 5895XL
conditions the RS 485 system bus
allowing an additional 6,000 feet of
wiring.
Operation
The green LED on the 5895X1
board indicates communication with
the IntelliKnight FACP
The FlexputrM circuits can be
notification appliance circuits,
continuous power, resettable
power, door holder power or
initiation circuits that can support
both 2- and 4-wire smoke
detectors. All FlexputrM circuits
and relay outputs are individually
mappable from the IntelliKnight
582OXL FACP
Features . 5.0A output power
. Flexput l/O circuits, 3A each,
programmable as notification
circuits, auxiliary power circuits,
or initiation circuits-. Supports Class A configuration
for SBUS & Flexput circuits . 2 Form C programmable relays
rated at 2.5A at
24VDC . Ground loop isolation . Transient protection
. SBUS repeater conditions the
RS 485 signal . 6,000 feet wiring distance from
58g5XL (same distance as main
FACP). Large cabinet can house two 17
amp hour batteries . UL 864 listed, complies with
NFPA 72 and 101 . CSFM
. MEA429-92-E, Vol.9 . FM approved
Specifications
Primary AC: 120 VRMS @
60 hz, 2,5 A
Total Accessory
Load: 5A@ 24 VDC
Current:
Standby 40 mA Alarm 160 mA
l/O Circuit
SILENT
KNIGHT
Model 5895XL
Power: 34 per circuit (5A
total per system)
Flush Mount
Dimensions:
14-112'W x24-314"H x 3-7l8"D
(36.8Wx62.9Hx9.8Dcm)
Overall Dimensions.
16-1/B"W x 26-3/8"H x 4-1l8"D
(40.6Wx67Hx11.8Dcm)
Color: Red
Model 5895xL
Intelligent Power Module
Engineering Specifications
The contractor shall supply a power module compatible with the IntelliKnight Model 5820XL FAC P. The power
module must have 5.0 amps of output power, Flexput l/O circuits rated 3.0 amps each, and two Form C relay
contacts rated at 2.5 amps at 24 VDC. The power module shall connect to the main FACP via an RS 485
system bus (SBUS). The power module shall contain an additional RS 485 bus that is completely compatible
with all lntelliKnight add-on modules, including 581sXL SLC Expanders, 5860 Remote Annunciators, 5824
Serial/Parallel Modules.
The power module RS 485 bus shall be optically isolated providing ground loop isolation and transient
protection. The unit shall be an SBUS repeater that conditions the signal driving 6,000 feet of additional wiring.
5895XL Installation Examole 5895XL Conneclion to FACP
582OXL FACP
31 30 A8
up to 6,000 feet. non-shFtd€d
NAC6 Aur powoi elc
5895X1.2 SBUS
2r 20 19 18 17 16 A B -. . A I
NA(:s Aux power elc
5424 5860
23 22 33 32 23 22 21 20 19 18 17 . +A8, +A
v
u3ed In
Clr(3 A
conf9uaal|ong
i t
u30d In
Cla6s A
contigur6l|ons
V
SaUS deuce a
o
E z
z
E
@ 5460 Io nen 5a95xL
stc I
t?! s[ENr II\I KNIGHT D"
7550 Meridian Circle, Maple Grove, MN 55369-4927
800-446-6444 0r in Minnesota 763-493-6435
FAX: 763-493-6475
World Wide Web: http;//www.silentknight.com
MADE IN AMERICA
FORM# 350212. Rev. 09/01
Copyright O 2001 Silent Knighl
IntelliKnight is a Registered Trademark or Silent Knight
Flexput is a Trademark of Silent Knight
sisnoling,,r.,,LLlif:l,i:l M
Add flexihility to IntelliKnighro opplicorions
with the 58lsxt SIC Exponder
The Model 581sXL SLC Expander is a signaling line circuit controller for Silent Knight's IntelliKnight
5820XL addressable fire control panel. lt allows you to add 127 addressable devices to the
IntelliKnight system. Three 581 SXLs can be added to the 5820X1 for a maximum of 508 addressabte
devices per IntelliKnight system.
5815X1 signaling circuits have the same functionality as the SLC that is built into the IntelliKnight
panel and support the same addressable devices as the main panel. The 5815X1 connects to the
panel via the RS 485 bus and is housed in the IntelliKnight 5820X1 or 5B95XL cabinet.
Model5Sl5X[
Signoling [ine (ircuil [xponder
The 581SXL expands the
capabilities of the IntelliKnight
fire control panel by allowing
127 additional addressable
devices to be attached to the
system.
All functionality of the built-in
SLC is provided with the
5815X1. Three 5815XLs can be
added to an IntelliKnight system
for a total of 508 addressable
devices per system.
0perution
The 5815XL communicates with
the IntelliKnight FACP via an
RS 485 system bus. A green
LED on the 5815XL board
blinks to indicate good
communication. lf an
addressable device on a
581sXL fails, the loop
communicates the failure to the
panel and continues to operate
normally.
Feotures
Adds 127 addressable to an
IntelliKnight system
Three 581SXLs per system
5815XL SLCs have same
functionality as built-in, including
Style 6 (Class A) configuration
Communicates with the
IntelliKnight panel via RS 485
system bus
LED indicates good
communication
Housed inside IntelliKnight
5820XL cabinet or remotely
mounted inside the 5895X1
cabinet.
UL 864 listed, complies with
NFPA 72 and 101
Communicates on most
standard wiring systems (ideal
for retrofits)
FM approved
SILENT
KNIGHT
58tsXL
IntelliKnight system
supports three 5815X1
SLC Expanders.
Each expander
supports 127
addressable devicesi
IntelliKnight system
supporls 508 devices
total.
Model
Specificotions
System Capacity
Operating Voltage 24 VDC
Current
Consumption
(standby and
alarm)
55 mA minimum -
125 mA max. (with 127
devices)
Ambient
Temperature
32oF to 120"F
(0'C to 49oc)
Inside IntelliKnight
FACP or 5895X1
cabtnet
Mounting
Model5Sl5X[
Signoling Line Circuil Exponder
Engineering Specificotions
The contractor shall provide a signaling circuit expander compatible with the IntelliKnight
5820XL fire control panel that allows 127 addressable devices to be added to the system,
The IntelliKnight panel shall support three expanders for a total of 508 addressable devices per
system. The expanders shall mount inside an IntelliKnight system cabinet, either the FACP
or the 5895XL. The expanders shall provide signaling line circuits that have the same
installation and functionality as built-in SLCs and shall communicate to the main panel via an
RS 485 system bus. A green LED on the expander board shall blink to indicate
communication with the main oanel.
SLC 16op 2 slc Loeg 3
FACP Cabinet
FACP
19 18 17 16 - + AB
23 22 21 20 +Aa
5815X1
I
Us€d in
Cbss A
configuralions
+ AB IN OUT
tv
58lsXt Block Diogrom
SILENT
KNIGHT
7550 Meridian Circle, Maple Grove. MN 55369-4927
800-446-6444 or in Minnesota 763-493-6435
FAX: 763-493€475
World Wide Web: http://wwwsilentknight.com
MADE IN AMERICA
FORM# 350098. Rev. 01/01
Copyright O 2001 Silent Knjght Security Systems
InlelliKnight is a Registered Trademark or Silent Knight
Flexput is a Trademark of Silent Knight
Addresssble Heot Defector
M
IntelliKnighto oddressoble heot detectors combine
qccurale heof defection with pin-point locotion lD.
An essentiol combinolion lor uny insfollotion.
IntelliKnight heat detectors are an essential component in virtually any lntelliKnight installation. The IntelliKnight
panel recognizes each detector by its specific address, so precious seconds are not wasted in determinino
location of an alarm.
Like other IntelliKnight detector models, the SD505-AHS offers a low profile for pleasing aesthetics.
The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6A8, allowng
complete application and placement flexibility. Combine all this with the features you've come to expect from
Silent Knight detectors---easy installation, stable operation, RF/transient protection, and vandal-resistant
locking-and it adds up to a flexible solution for all your fire protection needs.
tod.l SDS05.lllS
lddruoble lhot Dofodol
The SD505-AHS is a heat detector
suited to virtually any commercial
setting. The SD505-AHS is an
absolute temoerature device. This
means that it responds in alarm if
the temperature goes above the
trip point (programmed at the
panel).
The SD505-AHS provides accurate
temperature measurement data to
the fire alarm control panel. This
heat detector is particularly suited
to environments where smoke
detectors cannot be used because
of the presence of steam or
cooking fumes, such as in a
kitchen.
lf the temperature exceeds the trip
point (programmed at the panel),
an alarm occurs. The status LED
lights continuously during the alarm
oeriod.
Under normal conditions, the status
LED blinks approximately every 15
seconds, indicating that the head is
communicating with the loop.
holus . Low profile, 2 inches, including
base
. Absolute temoerature device
. Simple and reliable addressing
. Uses digital communication
orotocol
. The SD505-AHS is UL Listed
and meets the reouirements
outlined in NFPA 72 Insoection
Testing and Maintenance,
Chapter 7.
. CFSM listed
. MEA listed
. FM approved
gli.i:'
Heat Detector
17 to 41 VDC
Current Consumption:
Slandby: .55 mA Alarm: .55 mA
Detection Temperature
Range: 135'F to 150"F
(57.C TO 6s.C)
Ambient Temperalure: 32'F lo 100oF
(ooc to 37oC)
Mounting:4" SQR, 4' OCT
Single gang mud
ring
Rated Spacing:
SD505-AHS
Spodfrcdloilt
Operating Voltage:
The SD505-AHS unit is made up of
an externally mounted thermistor
with a specially designed cover that
protects the thermistor while
allowing maximum air flow. The
thermistor reads the temDerature
from the air it takes in. lt then
transmits a signal representing the
temperature to the IntelliKnight
oanet.
70'between
sensors on smootn
ceilings.
SILENT
KNIGIIT
Compatible Bases: SD505-6AB
(Sold Separately) (6" Base)
sD505-4AB
(4" Base)
Model SD505-AHS
Addressoble Heot Detector
Englneedng Spedfl otlon3
The contractor shall furnish and install where indicated on the plans, addressable heat detector Silent Knight
SD505-AHS. The combination detector head, and twist-lock base. shall be ULo listed compatible with Silent
Knight's IntelliKnight fire alarm control panels.
The base shall permit direct interchange with Silent SD505-APS Photoelectric Smoke Detector, or SD505-A|S
lonization Smoke Detector. Base shall be the appropriate twist-lock base SD505-6AB
The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the
flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset
switch.
The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The
locking feature shall be field removable when not required.
Voltage and RF/transient suppression techniques shall be employed to minimize false alarm potential.
Diameter = 3-15/16"
Height = 2 inches,
including base
Model SD505-6AB Detector Base
(Front View)
Model SD505-AHS Detector Head
(Front View)
.- Diameter = 5-15/16"
\-.-.... \.,
^..1'\ ti
(:)) )) ) I .
'Jt,//,,,/
,l
'/,,..14)'
( ' ('t,r)'l
\ \ \__//
\... ....-_--._,__.-,',..
"''----- ,,-"
\o./
til srLENr I('\3 KNIGHT D"
7550 Meridian Circle, Maple Grove, MN 55369-4927
800-446-6444 or in Minnesota 763-493-6435
FAX: 763-493-6475
World Wide Web: htto://www.silentknioht.com
MADE IN AMERIGA
FORM# 350229, Rev. 01/01
Copyright O 200'1 Silent Knighi
Addressuble
Photoelectric Type
Smoke Defecfor
Delect smoldedng fires quickly ond get help losl
wilh IntelliKnighto photoelectric smoke detectors.
IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where
smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS
photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds
are wasted in determining location of an alarm.
The SD505-APS compensates automatically for contamination in the environment. And detector testing is
simple---€ven from a remote site. Like other IntelliKnight detector models, the SD505-APS offers a low profile for
pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model
SD505-6A8, allowing complete application and placement flexibility. Combine all this with the features you've
come to expect from Silent Knight smoke detectors-easy installation, stable operation, RF/transient protection,
and vandal-resistant locking-and it adds up to a flexible solution for all your fire protection needs.
kdol SD50F|?3
fmbg /lilruoblo
Ploholedrlc lypo
Srob Ddodol
The SD505-APS is particularly
suited to detecting dense smoke
typical of fires involving materials
such as soft furnishings, plastic,
foam or other similar materials
which tend to smolder and produce
large visible particles.
The detector features automatic
compensation for contamination
and a simple detector calibration
test procedure that can be run from
the panel or remotely (using the
WindowsrM based downloadino
software).
Simple detector calibration
lesting through the control panel
or remotely through a
Windowsru based computer
software.
Vandal-resistance locking
features
Field cleanable
UL listed, meets NFPA 72 Ch 7
requirements
CSFM approved
MEA approved
FM Approved
4" Square, 4" OCI
Single gang mud
ring
The light received is converted into
an electronic signal. Under normal
conditions, the status LED blinks
approximately every 15 seconds,
indicating that the head is
communicating with the loop. The
LED lights continuously during the
alarm oeriod.
;offi . Low profile, 2 inches, including
oase . Simple and reliable addressing
without mechanical switches . Automatic compensation for
sensor contamination . Built-in fire test feature
SnbD.hdor
'17-41 VDC
Current Consumption:
Standby: .55 mA
Alarm: .55 mA
AmbientTemperature: 32'Fto'100'F
(ooc to 50oC)
Mounting:
Relative Humidity: 85o/o
noncondensing
Air Velocity:0 - 300 FPM
Compatible Bases: SD505-6AB
(Sold Separately) (6" Base)
SD5O5-4AB
(4" Base)
SILENT
KNIGI{T
SDffil?S
SpeCtottor
Operating Voltage:
The SD505-APS units made up of
an LED light source and a silicon
photo diode receiving element. In a
normal standby condition, the
receiving element receives no light
from the pulsing light source. In the
event or fire, smoke enters the
detector and light is reflected from
the smoke particles to the receiving
element.
Model SD505-APS
Addressoble Pholoelectric Type Smoke
Detector
Inglmodr{ SeeOnomr
The conkacior shall furnish and install where indicated on the plans, addressable photoelectric smoke detector
Silent Knight SD505-APS. The combination detector head, and twist-lock base, shall be UL@ listed compatible
with Silent Knight's IntelliKnight fire conlrol panels.
The base shall permit direct interchange with Silent Knight SD505-A|S lonization Smoke Detector, or SD505-
AHS Heat Detector. Base shall be the appropriate twisllock base SD505-6A8.
The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the
flashing LED will lalch on steady. The detector may be reset by actuating the control panel reset switch.
The calibration of the detector shall be capable of being selected and measured by the control panel without the
need for external test apparatus.
The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The
locking feature shall be field selectable as required.
The SD505-APS shall automatically perform a functional test of the detector. The test method shall simulate
effects of products of combustion in the chamber to ensure testing of detector circuits.
Height = 2 inches,
including base
hd.lSD50$6ll Dlhdchr {h*d hd.l SDt6{lS Drrfflld
foldrrl
Diameter = 3-15/16"
, ww& .-ffi *%.
ry!{fl , w w 6
'%* w
rFl s[ENr II\I KMGTIT D.
7550 Meridian Circle, Maple Grove, MN 55369-4927
AOO46-f6/,44 or in Minnesota 763493-6435
FAX: 763493-6475
World Wide Web: http://www,silentknioht.com
MADE II'I AilIERICA
FORM# 350225. Rev. 12l01
Copyright O 2001 Silent Knight
SD500-PS and SD500-PSDA 7;ll
Addressabre Pull-stat,on {lfl!
IntelliKnight's addressable pull stations
combine fast response with pin-point
location lD.
The SD500-PS and SDS0O-PSDA are a single action or dual action addressable manual fire alarm pull station
for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SDSoo-PS/PSDA
provides a fasl and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes
each manual pull station by its specilic address saving precious seconds in determining the location of an alarm.
The SDSO0-PS/PSDA mounts to a single gang box and feaiures a rugged metal construction that lasts and
lasts.
Combine all this wilh the features you've come to expect from Silent Knight - easy installation and stable
operation - and it adds up to a tlexible solution for all your fire protection needs.
Model SD500-PS &
SDsOO.PSDA
Addressable Pull
Station
The SD500-PS is a single action
addressable fire pull station, and
the SDS0o-PSDA is a dual action
addressable f ire pull station. The
SDSOO-PS/PSDA feature rugged
metal construction A terminal strip
on back ol the pull station allows
interconnection of the pull station to
the SLC of an IntelliKnight control
panel. The SD500-PS/PSDA is
designed for indoor use in non-
explosive environments. The
normally open initiating point
contacts are gold-plated to avoid
risk of corrosion. The SD500-
PS/PSDA has been tested by UL
for compliance to the requirements
ol the Americans with Disabilities
ACT (ADA).
Features
. UL Listed
. CSFM listed
. ADA compliant
. Key reset (Same key as Silent
Knight enclosures)
. Sudace mount back box
available
. Terminals - accept up to 14
gauge wire
Extremely easy to operate
Corrosion-resistant gold-plated
contacts.
Reflective label makes it easier
to locate in low light
Operation
The SD500-PS/PSDA single action
pull stations are operated by a pull
on the fronl pull cover ol the
station. A plunger switch, wired to
a self coniained addressable
module, is released as the pull
station opens to initiate the alarm.
Once operated, the cover hangs
down and can be seen uo to 100
feet away. The pull station is reset
by relurning the tront cover to the
normal upright position and
relocking lhe station with a reset
key. The reset keys are the same
keys used on Silent Knight
enclosures.
The SDS0O-PS/PSDA includes a
status LED which blinks, indicating
that the addressable module is
communicating with the loop. The
status LED lights continuously
during an alarm. A dip swilch on
the addressable module is used to
set the unique address.
Specifications
Operating Voltage: 24VDC
Standby Current: .55mA
Alarm Current: .55mA
SD5OO.PS
Ambient Temperature: 32'F to 120'F
(0"C to 49'C)
Mounling: Single gang
oox -
Oplional Red Surlace Mount Box PS-SMBB
SITENT
KNICHT
SD500-PS and SD5OO-PSDA
Addressable Pul l-Station
En gineering Specif ications
Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14
gauge C.B.S,(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and
be made of a rellective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on
the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the
key shall match the control panel.
Manual station shall contain four terminal blocks with lwo connecled to the addressable module and two connect
io the SLC loop. Manual station shall provide data to the control panel wilh an lD address programmed by dip
switch settings .
Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the
American Disabilities Act.
.t
, E't"-,.o'\
p
Mounting to Single
Gang Electrical Box
t
,
n v
Mounting to Optional
Surface Mount Box
SDsOO-PSDA
Wiring
t-
\
Er.<trrcrl !fi .n !l rr
Dimensions
-W
lnstalling SD500-LK
SITENT
KNIGIIT
7550 Meridian Circle, Maple crove, MN 55369-4927
8OO446-64/U or in Minnesota 763-493.6435
FAX: 763-493-6475
World Wide Web: http://www.silentknighl.com
MADE IN AIUIERICA
FOFM# 350342. Flsv. 09/03
Copyright O 2003 Silent Knight
Model SDs00.AlItl
Addressoble lnput [tlodule
And
ModelSDs00-ffilll
Miniolure Inpul Module
IntelliKnight's oddressoble contoct monitor modules
combine fosl response with pin-point locotion ID.
A combinolion ficf soves lives ond property.
The SD500-A|M and SD500-M|M are addressable input modules for use with Silent Knight's
IntelliKnight fire control panel. The SD500-A|M and SD500-M|M are designed to be used with putl
stations, water flow switches, and other applications requiring dry contact alarm initiation devices.
The SD500-A|M addressable input module mounts to a 4"-square box. The SD500-MlM mini input
module fits inside a single gang box. The modules are supervised, single input contact monitors.
Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault
conditions.
The SD500-AIM and SD500-M|M offer a compact design for adaptability and pleasing aesthetics as
well as easy installation and stable operation-a flexible solution for all your fire protection needs.
llodolSD50Gllil end
SDS0Gtlt lfinodd.c
The addressable input modules
expand the flexibility of the
IntelliKnight system by allowing the
use of contact type inputs. Typical
applications include manual pull
stations and water flow switches.
Fooiluu
. Operates on Class A (Style 6 & Style
7) or Class B (Style 4)SLC Loop.. Single contact monilor.
Up to 127 modules per SLC loop.
SD500-M|M mounls in a single gang
oox.
SD500-A|M mounts in a
4"-sguare or double gang electrical
box, and has an attractive ivory
cover olate.
SD500-AlM/MlM are DIP switch
programmable.
Accepts up to 14 gauge wire.
Both modules UL 864 listed: comply
with NFPA 72
2500 ft max. wiring distance from
input module to contact.
CSFM listed.
MEA 429-92-E, Vol. 9
FM approved
Ets
so500dril
Each addressable input module is
programmed with a unique SLC
loop address. The module
supervises the wiring to the contact
with an End Of Line (EOL) resistor.
lf a fault occurs in the wiring, the
module alerts the FACP
Ambient Temperature: 32'F to 120oF
(fc to 49oC)
Mountingl
SeeCfafonr
Operating Voltage:
sos00*Irl
24 VDC
Standby Current:
Alarm Current:
0.55 mA
0.55 mA
sD500-ArM
double gang box or
4'-square electrical
box
SDSOO-MIM
sangle gang box
SITENT
KNIGHT
trlodel sD500.AlM ond sD500-mtill
Addressoble Input ond Mini Input Modules
Engineering Specilicotions
The contractor shall furnish and install where indicated on the plans, addressable input
modules Silent Knight SD500-A|M or SD500-MlM. The modules shall be UL listed and
compatible with Silent Knight's lntelliKnight FACPs.
The SD500-MlM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied
with a plastic cover and shall be suitable for mounting to a 4"-square or double gang electrical
box. The SD500-A|M addressable input module must provide a monitor LED that is visible
from outside the cover plate.
irodcl SD500-Alil
FROTT VIEW
EIH"
Model SD500. ltu
2-ln'
ffilJ'"'*ffi
ril s[ENr I\\iA KNIGI{T T.
7550 Meridian Circle, Maple Grove, MN 553694927
4o1}4466444 or in Minnesota 763-493-6435
FAX: 763-493-6475
World Wide Web: http://www.silentknight.com
TADE 11{ AMERICA
FORM# 350231, Rev. 11/01
Copyright @ 2001 Silent Knight
Self-Diagnostic Photoelectric
Smoke Detectors
Installation Instructions
Part Number 14153
California State Fire Marshal Approved
MEA (New York City) Approved
6)
X# ornr++s
Esr4@ +z"u}asERrEs
428/448 @
GENERAL DESCRIPTION
The ESL 4291449 and 428/448 Series low-profile, sell-diagnostic, two-
and four-wire smoke detectors work on the light scattering principle. A
pulsed infrared light-emitting diode serves as the light source, and a
high-speed photo-diode as the sensing element. This design has
superior protection against false alarms caused by dust, insects, RF
and ambient-light.
These Series of smoke detectors are especially suited for residential
occupancies, including hotels, motels and dormitories, as wellas other
commercial and industrial flre-system applications. This Series is
designed for 2-wire and 4-wire connection, respectively, to 6-24 V DC
fire alarm conlrol panels, UL Listed for commercial or household fire
Drotection.
Plug-in terminal block
Diaoram 1
429 &428.
Diagram 2
Series Wating Diagram
model429CBT
fiilifi "or
usea Power
/J.-.^_/J\._
Two-Wire Compatibility
The ESL 429 Series two-wire, smoke detectors
otfer the widest range of two-wire compalibility
in the industry. Refer to ESL'S Compatibility
Index for compatible control panel listings.
last
detector
'----+El I
'
I END OF LINE HEI DEVtcE
CBT, CSRI CLT, CSLI
cLT SCITj c.nlads |,owe'
Dc l+.
rarnrrg t{jrr sensor
--i:.i:_'.-_
'448CSH and 448CSRH are smoke alarms.
Wire Type Model
Designator Power
6/12 V DC
c 12t24 V OC
Wire Type Power Designator
Featu res
Oeslgnator Fealure De3cription
E End'o1-Line Power
Supervisory and S€nsilivity
Slatus R€lay
Builtrn end.ol-hne relay thal also acts as a sensitivily slatus oulpul. For four wrre only. fail-sale relay lflps upon loss of power or il
smoke delector is outside the approved sensrtNity range lor more lhan one day Fnd of line resistor is easrly con4ected 10 lerm;nal
with no €xtra wirjno, or relay contacls can be Donnected lo a Separate lrouble loop.
lsolaled Fixed Temp. and
Flate ol Flise Heat D€tector
lsolaled fixed 135"F (57'C) and rate of rise heat d€t€ctor, independently lrips the LED and alarm relay oulpul. Smoke delector
activates internal sounder (local alarm) and auxiliary relay, but does not lalch. Approv€d as both single staiion smoke alarm and
system heal cleleclor, ldeal lor hotel, motel and dormitoty rooms where smoking is allowed.
R Used to actival€ othet devices such as elevator r€call, door hangers, elc. UL Listed lor releasing services.
Built'in Soundef 85db builfin soundor alafms when smoke is delecied or when power wilng polarily is reversed.
SS Built'in Soundor with
Sensitivily Stalus Output
85db built in sound€r alarmg when smoke is detectod or when power wi ng po{arity is reversed. AIso. clrirps wh6n unitgoes outside
lhe approved sensitivity range lor more than on€ day. Resetling deteclorwill 6il6nce chirp lor one day. unril unity s restofed lo
Propel sensilivily.
T Inteqraled Frxed Ten9. and
Ratd ol Rise Heat Deiectoi
lnteqraled trxed 1 35'F (57ocj lemperature and rat€ ol rise head deteclor ofters double pfolection. Either heat del€ctor of smoke
dete.-clor can trip and laich LED arid alarm relay oulplrts.
L Low Temperature Ouipul Non latching, low lemperature oulput for temperatures below 43'F t 5'F ('C).
Electrical Speclf ications
Model 2-Wlrs /hWire Min.Volt.Max, volt.
Max. Ripple
(PK To PK)(vl
Typ. Ave. Stby.
Cur. (12-24V)
(uA)
Typ. Alarm Cut.
(12-24v)
(mA)
Typ. Ave. Pol.
Rev. Cur"
(mA)
Alarm Relay
Contacts
(al
Olher Relay
Contacls
{A)
429A1,42aAr 20 0%70 'see S09A
429C, 428C 33 o"/"-70 'see S10A
429Cr,42ACT 8.5 0%70 'see S10A
429CRT 33 o7"70 -see 511A 2
429csT.428CST.42g6ST 33 10v.70 'see 511A 10
33 10"/.70 15 0.5
449CT. 448CT 10%70 15 0.5
449CRT 8.5 33 10"k 70 31 0.5
449CLT,448CLT 33 't07"70 15 0,5
449AT, 44847 5.1 27 10%70 15 0.5
449CST. 448CST 33 10"/"70 40 10 0.5
449CSRT 1046 70 10
449CSLT, 448CSLT 6.5 100k 70 40 10 0.5
449CSRH 10%70 10 0.5
449CSST 33 10.h 70 40 10 0.5
449CSTE. 449CSSTE 33 10%23mA 5l 33 0.5 2
449CTE, 44ECTE 10"k 23mA 23 0.5 2
44BCSH*8.5 33 10v6 70 10 0.5
448CSRH"10"k 7Q 51 '10 0.5 2
204-6V (UL Lislsd)5.1 15 33mA@6VDC 0.5
204-12i24V (UL Listed)8.5 33
14 mA @ 12V DC
28mA @ 24V DC 0.5
204-12/24V CAN (ULC Listed)8.5 33
14 mA @ 12V DC
28mA @ 24V DC 0.5
. 429 models draw up to a maximum of 60mA alarm current if not limited by panel.
Product Data
Sensitivity
42al44a - minimum ............... 2.0 + 0.50o/"/Ft.
- maximum 2.0 - 0.50"/"lFt.
4291449 - minimum...........-... 2.0 + 0.37"/"lFl.
- maximum 2.0 - O.39Y"/FI.
Operating temp .... 32'F to 120'F (0'C to 50'C)
Operating humidity range............. 0 to 95% RH
Sounder specifications 85 dB at 10 Ft.
Color...............-............. white cover/white base
Field wiring size...................... 1 4-24 AWG
Heat detector specitications ... tixed temperature - 135'F, 50 ft. spacing
rate ol rise - 15"F/min. & > 105'F (8.3"C/min. & > 40.6'C)
Low temp specjfications.........43"F ("C) r 5'F ('C)
Auxiliary relay contacts ..........24 @ 28 V DC or 120 V AC (resistive)
Alarm contacts .....".................500 mA @ 36 V DC (resistive)
Detector size ..........................6.1 in. (15.5 cm) x D 1.85 in. (4.69 cm) x 8.8 oz. (0.25 kg) W
Packaging ...10 detectors are packed in a carton
Sell-diagnostic indication ....... typically 27 hours alter reset (do not connect to power
supply that resets every 24 hours)
O1999 Sentrol. Certain items in the Installation Instructions are protected under one or more of the following patents: 5,546,074;
5,7O8,41 4i 5,798,70'1 ; 5,821,866; 5,936,533.
ESLffi
SENTROL
12345 SW Leveton Dr., Tualatin. OR 97062
Tel.: 503.692.4052 Fax: 503.691.7566
http:/,vwwsentrol.com
U.S. & Canada: 800.547.2556
Technical Seryice: 800.648.7424
FaxBack: 1.800.483.2495
Sentrol reserves the right
to change specifications
without notice.
O1999 Sentrol
A PRODUCI OF SENTROI
E,3S14-0999
14153 Rev. B
GiEI\ITEX
Gommande13 Series Selectable
Candela Evacuation Signals
Applications
The Commander3 Series is a low
profile strobe or horn/strobe
combination that offers deoendable
audible and visual alarms and the
lowest current available.
The GE3 Series offers field
selectable candela options of 15, 30,
60, 75, and 110 can{ela.
The Commandero Series horns
offer a new synchable chime and
whoop tone and provide a selection
of high or low dBA as well as a
selection ol a 2400 Hz (remote
signaling) or a low frequency broad
band 1500-3000H2 mechanical
sounding (evacuation) tone where
doors could be a oroblem.
The GE3 Series are easily field
changeable from temporal 3 to a
continuous tone by simply removing a
jumper. The GEC3 is shipped from
the factory on the temporal lower
frequency mode and it comes
standard with a rugged cast metal
mounting plate.
The CommanderJ has a minimal
operation current and has a minimum
flash rate of 1Hz regardless of input
voltage.
The CommanderJ Series comes
standard with the 4" mounting plate
which incorporates the popular
"SupersliderM" feature that allows you
to easily test for supervision. Also
included is a locking mechanism
which secures the product to the
bracket without any Fcrews showing
The Commanded (GE3 Series)
appliances are UL 464 and UL 1971,
listed for use with fire orotective
systems and are wananted for three
yean fiom date of purchase.
Standard Features
. Field selectable candela options of 15, 30, 60, 75,
and 110 candela . Prewire Entire System, Then Install Your Signals . Ease of Supervision Testing (Super Slide"). Lower Installation and Operating Costs . Input Terminals 12 to 18 AWG . Switch Selection for High or Low dBA . Switch Selection for High or Low Frequency
('1500-3000 Hz). Switch for Temporal 3, Chime, or Whoop Tones
. Tamperproof Re-entrant Grill
Surface Mount with the GSB (Gentex Surface
Mount Box)
Synchronize Strobe and/or Horn by Using the
AVS-44 Control Module
Silence Horn While Strobes Remain Flashing
Rugged Die Cast Metal Mounting Bracket
True Evacuation Tone
. Wide Voltage Range '16-33 VDC or FWR . Seoarate Horn and Strobe Functions . Available in Red or Off-White
Approvals
'@"ffi'g.H
Amoricans with Disabilitiss Act (ADA 4.28.3)
BFP (Clty of Chicago)
BS+A/MEA #285-91.E
CSFM 7135.0569:122 (GEC3l
7125.0569:123 (GES3)
NFPA 72
UL ULC Dual Listed 464. 197.|
GES3 24VDC Selectable Candela Low Profile Evacuation Strobe Wall Mount
Model Number Part Number Nominal Gandela
Voltase (uL 1971)
GES3-24WR 904-1321-002 24VDC 15,30, 60.75. 110
GES3-24WW 904-1319-002 24VDC 15,30, 60.75, 110
GES3-24PWR 904-1322-002 24VDC 15.30, 60.75. 110
GE53-24PWW 904-1320-002 24 VDC 15,30, 60,75, 110
GEC3 24VDC Selectable Candela Low Profile Evacuation Horn/Strobe Wall
Notes:
The GE3 Series is not listed for outdoor use. Operating temperature: 32'to 120"F (0. to 4g' C)
Model designations:
"W" = Wall Mount
"R" = Red Faceplate
"W" = Off-White Faceolate
"P" = Plain (no lettering) Available with all models. These units are non-returnable.
"Agent" bezel also available.
Operatinq Strobe Current @ 24VDC
15 Candela 55mA
30 Candela 63mA
60 Candela 88mA
75 Candela 12mA
1 10 Candela 136mA
Nole: For nominal and peak current across UL regulated voltage range for filtered DC
power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual.
DBA @ l0 ft. per
UL464 (Hiohl
DBA @ l0 ft. per
UL464 (Low)
Dc (mA)
Horn Mode 16v 24v 33v 16\,AY 33v 1ev 24v 33v
Temo 3 2400H2 7a 83 a4 71r 75 13 'ts 24
TemD 3 Mechanical 76 81 82 70.tat TO 16 22
TemD 3 Chime 70'71'71'66'70-I 't2 15
Continuous 2400H2 81 do 87 74'78 80 14 21 28
Continrmus Mechanieal RO 84 85 72',76 7A 13 18 2A
Conlinuous Chime 71',73-66t 68-70-'t0 12 15
Whooo a)83 83 69.72*75 43 51 56
*Operating the horn in this mode at this voltage will result in not meeting the minimum UL reverberant sound level required
for public mode fire protection service. These settings are acceptable only for private mode flre alarm use. Use the high
dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private
mode).
Notes: The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound
output rating.
While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous
mode.
Model Number Part Number Nominal Candela dBA @
Voltage (uL 1971)10 Ft.
GEC3.24WR 904-1317-002 24 VDC 15,30. 60.75. 110 100
GEC3-24WW 9M-1315-002 24VDC 15,30, 60,75, 't10 100
GEC3-24PWR 904-1318-002 24VDC 15,30, 60,75, 110 100
GEC3.24PWW 904-1316-002 24VDC 15,30, 60,75, 110 100
Dimensions
Switch Locations
Mounting Super Slide*
Die Cast Metal Mounting Plate: Mounts to single gang,
double gang 4" square boxes or GSB box.
Candela
Selection
candela saleclion slider
e,vilcn 0spr€6s @nt€.
snd sl d€ s{nch to d.6i.€d
Br€k oi{ pi. snd insen i o
hole ,l lh. botlom of the
s€l€clorlo lo(t candela 56lring.
SignalmDst be removed from
b.a.k.! ffd pin FishsdfoMard
fmm b&ksrde @t of hole
Conventional GES3/GEC3 Series Wiring Diagrams
S/VITCH POSTION
ime.TBmp.
ON > HIGH dB
OFF> LOW dB
Srrilch posilifis I .nd 2
in the ofl eorition to 3etect
irol.t.d horn and strob€
power inpule,
EHHHHE 12 3 4 5 6
Removing Bezel
h Grip borh \ t , sides of I i I bezel and /iFjl purrina
i | | ll downward
.f lRll ano.ourwaro
I lijil moron 'ril /'(l
ut tbbd
Gorillol
Pr il
A|p. H ggrdCbcdt
Wiring Diagram GE3 Serles with AVS44 Synchronization Module
.rnlINL *t?
5rI n|'
Architect & Engineering Specifications:
The audible and/or visible signal shall be Gentex GE3 Series or approved equal and shall be listed by Undenrvriters
Laboratories Inc. per UL 1971and/or UL 464. The notification appliance shall also be listed with the California State Fire
Marshall (CSFM)and the Bureau of Standards and Appeals (NYC).
The notification appliance (combination audible/visible) shall produce a peak sound output of 100dBA or greater at 24V
as measured in an anechoic chamber. The signaling appliance shall also have the capability to silence the audible signal
while leaving the visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to
select either conlinuous or temporal tone output with the temporal signal having the ability to be synchronized.
Unit shall be capable of being inslalled so that any unauthorized attempt to change the candela setting will result in a
trouble signal at the fire alarm control panel.
The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or greater regardless
of powerinputvoltage. Theapplianceshall haveanoperatingcurrentof 55mAorlessat24VDCforthelsCdstrobecircuit
The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a
mounting bracket with terminals with baniers for input/output wiring and be able to mount to a single gang or double gang
box or double workbox without the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with
either direcl cunent of full wave rectified oower.
The appliance shall be capable of testing supervision without disconnecting wires. Also the appliance shall be capable of
mounting to a surface back box.
GiENTEX CCtHFEIFIATIClN
Firc Prctedbn Prcducb: wlw.gentsx.corn
10985 Chft=go Dr., Box 310, Zedand, Ml 4944t
616tsS2-7195 1€0043S83S1 FAX: 6168924219
G6nt6x corpo€lion res€rv63 lhe dght to mako changes to the prcducl data sh€€t6 et lheir discretion- O Printed on Recydgd Paper
24 units per carton
27 pounds per €rton
GE30201-3
GiENTE)(
12 or 24VDC, Low Current Mini-horn,SERIES
Temporal (GX93) or Continuous (GX91)
tone, with Terminal Blocks
Applications
The GX91/GX93 Series mini-horn is a
high quality remote signaling appliance that
offers deoendable remote annunciation.
The GX91/GX93 is listed for use with
both filtered and unfiltered power.
The GX91 is a continuous tone mini horn.
This unit is not synchable with the AVS44
control module. lt is however synchable
from the oanel.
With the GX93 a jumper is provided to
select eilher the continuous tone or the
temporal 3 evacuation tone.
The GX93 can be used on the same sync
circuit (AVS44) as other Gentex signals
such as the Commander series.
The GX91/GX93 appliances are UL 464
listed for use with fire protective systems
and are warranted for three years from the
date of Durchase.
GXgl/GX93
Remote Audible Signal Standard Features
. Slnglo Unit is capable ot12or24
VDC determined by the input
voltage . Selectable Temooral 3 or Continuous
Tone on the GX93 (Jumper Pin). GXglhas a Continuous Tone horn
only . Horn Frequency is 3100H2 . Terminal Blocks (12 AWG to 18 AWe). Low Current Consumption
Available Models
Variety of Mounting 0ptions for New
Conshuction and Retrofit Applications
To Synchronize the GX93 use the
Gentex AVS44 Control Module
UL 464 Listed for Fire Protective
Service
Textured Finish High lmpact Plastic
Faceplate, Available in Fire Alarm
Red or Off-White
Approvals
'G"ErilEffi
. BFP (City of Chicago). BS+A[||EA#285.91.E.XV|. CSFII Listing 7135-0569:126 . UL ULC Dual llsted 464
Model
Number
Part
Number
lnput
Voltage
Horn
Current
Range (mcan DC)
ln Anechoic
Room dBA
@10Fr.
ln UL Reverberant
Room Per
uL 464 @ 24VDC
GXglR 904-'t274 6-JJ V 4-17mA 90 85 dBA
GXg1W 904-1275 8-33 v 4-17mA 90 85 dBA
GXg3R 904-1276 8-33 v 5-25mA 90 81* dBA
GX93W 904-'t277 8-33 v 5-25mA 90 81* dBA
Input Voltage Range: 8-33 VDC OR VFWR
GX91 Average Horn Current is 1smA @24VDC
Operating temperature
Indoor: 32" to 120'F 0" to 49"C
GX93 Average Horn Current is 22mA @24VDC
* The sound output for the Temporal 3 tone is rated lower since the time the horn is off
is averaged into the sound output rating, While the horn is producing a tone in the
Temporal 3 mode its sound pressure is the same as the continuous mode.
Red faceplate
Off-White hceolate
"ff=
GENTEX
SERIES
EIO# UHE lelsnn
4 units per carton
pounds per carton
GiENTEX CClHFclFIATIC!N
Fire Protection Products: www.gentex.com
10985 Chicago Dr,, Zeeland, Ml 49464
616/392-7195 1-800/436-8391 FAX: 616/392-4219
Genler corporalion res€N€s the .ight to make changes to the product data sheels at their discrerDn.
Trim Plate for GX91/GX93
Architect & Engineering Specifications
The alarm hoins shall -be'Gentex Model
GXg1/GX93. The appliance shall be listed with
Underwriters Laboratories for use with Fire
Protective Signaling Systems and produce a
peak sound output of 90dBA or greater as
measured in an anechoic chamber. The
appliance shall be of solid-state construction
and be polarized to operate from 8-33 VDC with
a 15 milliamp cunent drain on the GX91 and a
22 milliamp'current drain on the GX93 at 24
VDC. The appliance shall be provided with 2
terminals, and mount to a variety of single-gang
back boxes.
SGP-R SGP-W