Loading...
HomeMy WebLinkAboutB12-0198 APPLICATIONDepartment of Community Development 75 South Frontage Road Vail,CO 81657 Tel:970-479-2128 www.vailgov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm &sprinkler)r-----------------------------------------, Applicant Information Applicant Name:JJ Gold &Company,Inc Applicant Phone:_9_7_0_-3_9_0_-1_9_5_5 _----------------------------------------- Applicant E-Mail:tgold1226@aol.com Project Street Address: 1476 Westhaven Dr 20 (Number)(Street)(Suite #) Building/Complex Name:Coldstream Condominiuims Contractor Information Business Name:JJ Gold &Company,Inc Business Address:PO Box 2055-------------------------------- State:_C_O__Zip:81631CityEagle Contact Name:Jeff Gold----------------------------------- Contact Phone:970-390-1955 Contact E-Mail:TGold1226@aol.com I hereby acknowledge that I have read this application,filled out in full the information required,completed an accurate plot plan, and state that all the information as required is correct.I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws,and to build this structure according to the town's zoning and subdivision codes,design review ap- proved,International Building and Residential Codes and other ordinances of the Town applicable thereto. Project Information L d W ttOwnerName:an on ya Parcel #:210312108020 (For Parcel #,contact Eagle County Assessors Office at (970-328~640 or visit www.eaglecounty.uslpatie) For Office Use Only: Fee Paid:_ Received From:~_ cash Check #_ CC:Visa /MC Last 4 CC #exp date:_ Auth #_ Project #:_ DRB#:_ Building Permit #:_ Lot #:Block #__Subdivision:_ Work Class:New a Addition @ Alteration (0 Type of Building: Single-Family 0 Duplex a Multi-Family ~ Commercial 0 Other 0---------------------- Work Type:Interior 0 Exterior 0 Both @ Work Included Plans Included Electrical -'eVes ONe o-0No Mechanical Dves (!»)NO Oves 0No Plumbing Dves 0NO Oves @No Building eVes ONO 0ves ONO Valuation of Work 2200.00 28000.00 Value of all work being performed:$3_02_0_0_ (value based on IBC Section 109.3 &IRC Section 108.3) Electrical Square Footage 80 Detailed Scope and Location of Work:..;:E:..:n.;..:c:..:.lo::.:s::.;i.:,.:nS!g_ Master bedroom deck to livable area (use additional sheet if necessary) Date Received: 12-Mar-2012 Indoor Environmental Services, Inc Project: Coldstream, Unit 20 Vail, Colorado Asbestos Sampling Report – Page 1 of 2 May 11, 2012 Jeff Gold JJ Gold & Co. On May 9, 2012, Quentin Danziger conducted an asbestos inspection of the suspect materials to be affected by a planned remodel.Asbestos was NOT found, as described below. Homogenous Area Description Number of Samples % Asbestos Square Feet Type/Friable? 01 Sheetrock and Joint Compound 3 Non-Detect 02 Texture 3 Non-Detect 03 External Building Wrap 3 Non-Detect BACKGROUND: A remodel is planned, which is isolated to one external wall in one bedroom. Indoor Environmental Services was requested to conduct an asbestos inspection of the suspect materials to be affected. This inspection includes only suspect materials that are visible to the inspector. If other suspect materials become visible during demolition, they must be sampled before they are disturbed. Examples of suspect materials include but are not limited to: linoleum, floor tile, ceiling tile, mastic, sheetrock, joint compound, roofing materials, etc. There are over 3000 known asbestos containing materials. SAMPLING PLAN: Colorado State Requirements - For each homogenous area of less than 1000 square feet, a minimum of three samples must be collected in random areas. For each homogenous area of 1000 – 5000 square feet, a minimum of five samples must be collected in random areas. Areas of 5001 square feet or greater require a minimum of 7 samples. These laws are defined by the EPA (AHERA) and Colorado State Regulation 8. Indoor Environmental Services, Inc Project: Coldstream, Unit 20 Vail, Colorado Asbestos Sampling Report – Page 2 of 2 Determination of homogenous sampling areas – Homogenous Areas are determined by type of suspect material, texture, color and location. Determination of random sampling areas – The samples were collected in a random manner within each homogenous area. Thank you for using Indoor Environmental Services, Inc. We are proud to be your local indoor air quality consultants. We look forward to working with you in the future. Quentin Danziger, BS, ABI – Colorado Asbestos Inspector Certification # 12781 Indoor Environmental Services, Inc. 970-390-0087 ColoradoAsbestos.com EMSL Analytical, Inc. 1010 Yuma Street, Denver, CO 80204 Phone/Fax:(303) 740-5700 / (303) 741-1400 http://www.emsl.com denverlab@emsl.com 221201636 CustomerID:INES78 CustomerPO: ProjectID: EMSL Order: Attn:Quentin Danziger Q Consulting, Inc. PO Box 997 Vail, CO 81658 Received:05/10/12 10:25 AM Coldstream 20 Fax: Phone:(970) 390-0087 Project: 5/10/2012Analysis Date: Collected:5/9/2012 Sample Description Appearance % Type AsbestosNon-Asbestos % Fibrous % Non-Fibrous Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy 01-01-Texture 221201636-0001 Sheetrock / Joint Compound White None Detected Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Non-fibrous (other)100% 01-01-Tape 221201636-0001A Sheetrock / Joint Compound White None Detected Fibrous Homogeneous Cellulose100%Non-fibrous (other)0% 01-01-Joint Compound 221201636-0001B Sheetrock / Joint Compound White None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 01-01-Drywall 221201636-0001C Sheetrock / Joint Compound Brown/White None Detected Fibrous Heterogeneous Cellulose10% Glass3% Non-fibrous (other)87% 01-02-Texture 221201636-0002 Sheetrock / Joint Compound White None Detected Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Non-fibrous (other)100% 01-02-Tape 221201636-0002A Sheetrock / Joint Compound White None Detected Fibrous Homogeneous Cellulose100%Non-fibrous (other)0% 01-02-Joint Compound 221201636-0002B Sheetrock / Joint Compound White None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 1Test Report PLM-7.16.0 Printed: 5/10/2012 3:54:33 PM Erin Orthun, Laboratory Manager or other approved signatory Analyst(s) EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. None Detected = <1% Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0 Initial report from 05/10/2012 15:54:33 Donna Nading (7) Molly Walker (14) EMSL Analytical, Inc. 1010 Yuma Street, Denver, CO 80204 Phone/Fax:(303) 740-5700 / (303) 741-1400 http://www.emsl.com denverlab@emsl.com 221201636 CustomerID:INES78 CustomerPO: ProjectID: EMSL Order: Attn:Quentin Danziger Q Consulting, Inc. PO Box 997 Vail, CO 81658 Received:05/10/12 10:25 AM Coldstream 20 Fax: Phone:(970) 390-0087 Project: 5/10/2012Analysis Date: Collected:5/9/2012 Sample Description Appearance % Type AsbestosNon-Asbestos % Fibrous % Non-Fibrous Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy 01-02-Drywall 221201636-0002C Sheetrock / Joint Compound Brown/White None Detected Fibrous Heterogeneous Cellulose10% Glass3% Non-fibrous (other)87% 01-03-Texture 221201636-0003 Sheetrock / Joint Compound White None Detected Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Non-fibrous (other)100% 01-03-Tape 221201636-0003A Sheetrock / Joint Compound White None Detected Fibrous Homogeneous Cellulose100%Non-fibrous (other)0% 01-03-Joint Compound 221201636-0003B Sheetrock / Joint Compound White None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 01-03-Drywall 221201636-0003C Sheetrock / Joint Compound Brown/White None Detected Fibrous Heterogeneous Cellulose10% Glass3% Non-fibrous (other)87% 02-01 221201636-0004 Texture White None Detected Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Non-fibrous (other)100% 02-02 221201636-0005 Texture White None Detected Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Non-fibrous (other)100% 2Test Report PLM-7.16.0 Printed: 5/10/2012 3:54:33 PM Erin Orthun, Laboratory Manager or other approved signatory Analyst(s) EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. None Detected = <1% Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0 Initial report from 05/10/2012 15:54:33 Donna Nading (7) Molly Walker (14) EMSL Analytical, Inc. 1010 Yuma Street, Denver, CO 80204 Phone/Fax:(303) 740-5700 / (303) 741-1400 http://www.emsl.com denverlab@emsl.com 221201636 CustomerID:INES78 CustomerPO: ProjectID: EMSL Order: Attn:Quentin Danziger Q Consulting, Inc. PO Box 997 Vail, CO 81658 Received:05/10/12 10:25 AM Coldstream 20 Fax: Phone:(970) 390-0087 Project: 5/10/2012Analysis Date: Collected:5/9/2012 Sample Description Appearance % Type AsbestosNon-Asbestos % Fibrous % Non-Fibrous Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy 02-03 221201636-0006 Texture White None Detected Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Non-fibrous (other)100% 03-01-Paint 221201636-0007 External Building Paper Olive None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 03-01-Paper 221201636-0007A External Building Paper White None Detected Fibrous Homogeneous Synthetic100%Non-fibrous (other)0% 03-02-Paint 221201636-0008 External Building Paper Olive None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 03-02-Paper 221201636-0008A External Building Paper White None Detected Fibrous Homogeneous Synthetic100%Non-fibrous (other)0% 03-03-Paint 221201636-0009 External Building Paper Olive None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 03-03-Paper 221201636-0009A External Building Paper White None Detected Fibrous Homogeneous Synthetic100%Non-fibrous (other)0% 3THIS IS THE LAST PAGE OF THE REPORT.Test Report PLM-7.16.0 Printed: 5/10/2012 3:54:33 PM Erin Orthun, Laboratory Manager or other approved signatory Analyst(s) EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. None Detected = <1% Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0 Initial report from 05/10/2012 15:54:33 Donna Nading (7) Molly Walker (14)