HomeMy WebLinkAboutB12-0198 APPLICATIONDepartment of Community Development
75 South Frontage Road
Vail,CO 81657
Tel:970-479-2128
www.vailgov.com
Development Review Coordinator
BUILDING PERMIT APPLICATION
(Separate applications are required for alarm &sprinkler)r-----------------------------------------,
Applicant Information
Applicant Name:JJ Gold &Company,Inc
Applicant Phone:_9_7_0_-3_9_0_-1_9_5_5 _-----------------------------------------
Applicant E-Mail:tgold1226@aol.com
Project Street Address:
1476 Westhaven Dr 20
(Number)(Street)(Suite #)
Building/Complex Name:Coldstream Condominiuims
Contractor Information
Business Name:JJ Gold &Company,Inc
Business Address:PO Box 2055--------------------------------
State:_C_O__Zip:81631CityEagle
Contact Name:Jeff Gold-----------------------------------
Contact Phone:970-390-1955
Contact E-Mail:TGold1226@aol.com
I hereby acknowledge that I have read this application,filled out
in full the information required,completed an accurate plot plan,
and state that all the information as required is correct.I agree to
comply with the information and plot plan,to comply with all Town
ordinances and state laws,and to build this structure according to
the town's zoning and subdivision codes,design review ap-
proved,International Building and Residential Codes and other
ordinances of the Town applicable thereto.
Project Information L d W ttOwnerName:an on ya
Parcel #:210312108020
(For Parcel #,contact Eagle County Assessors Office at (970-328~640 or visit
www.eaglecounty.uslpatie)
For Office Use Only:
Fee Paid:_
Received From:~_
cash Check #_
CC:Visa /MC Last 4 CC #exp date:_
Auth #_
Project #:_
DRB#:_
Building Permit #:_
Lot #:Block #__Subdivision:_
Work Class:New a Addition @ Alteration (0
Type of Building:
Single-Family 0 Duplex a Multi-Family ~
Commercial 0 Other 0----------------------
Work Type:Interior 0 Exterior 0 Both @
Work Included Plans Included
Electrical -'eVes ONe o-0No
Mechanical Dves (!»)NO Oves 0No
Plumbing Dves 0NO Oves @No
Building eVes ONO 0ves ONO
Valuation of
Work
2200.00
28000.00
Value of all work being performed:$3_02_0_0_
(value based on IBC Section 109.3 &IRC Section 108.3)
Electrical Square Footage 80
Detailed Scope and Location of Work:..;:E:..:n.;..:c:..:.lo::.:s::.;i.:,.:nS!g_
Master bedroom deck to livable area
(use additional sheet if necessary)
Date Received:
12-Mar-2012
Indoor Environmental Services, Inc
Project: Coldstream, Unit 20
Vail, Colorado
Asbestos Sampling Report – Page 1 of 2
May 11, 2012
Jeff Gold
JJ Gold & Co.
On May 9, 2012, Quentin Danziger conducted an asbestos inspection of the suspect
materials to be affected by a planned remodel.Asbestos was NOT found, as described
below.
Homogenous
Area
Description Number of
Samples
% Asbestos Square
Feet
Type/Friable?
01 Sheetrock and
Joint Compound
3 Non-Detect
02 Texture 3 Non-Detect
03 External Building
Wrap
3 Non-Detect
BACKGROUND:
A remodel is planned, which is isolated to one external wall in one bedroom. Indoor
Environmental Services was requested to conduct an asbestos inspection of the suspect
materials to be affected.
This inspection includes only suspect materials that are visible to the inspector. If other
suspect materials become visible during demolition, they must be sampled before they
are disturbed. Examples of suspect materials include but are not limited to: linoleum,
floor tile, ceiling tile, mastic, sheetrock, joint compound, roofing materials, etc. There are
over 3000 known asbestos containing materials.
SAMPLING PLAN:
Colorado State Requirements - For each homogenous area of less than 1000 square
feet, a minimum of three samples must be collected in random areas. For each
homogenous area of 1000 – 5000 square feet, a minimum of five samples must be
collected in random areas. Areas of 5001 square feet or greater require a minimum of 7
samples. These laws are defined by the EPA (AHERA) and Colorado State Regulation 8.
Indoor Environmental Services, Inc
Project: Coldstream, Unit 20
Vail, Colorado
Asbestos Sampling Report – Page 2 of 2
Determination of homogenous sampling areas – Homogenous Areas are determined by
type of suspect material, texture, color and location.
Determination of random sampling areas – The samples were collected in a random
manner within each homogenous area.
Thank you for using Indoor Environmental Services, Inc. We are proud to be your local
indoor air quality consultants. We look forward to working with you in the future.
Quentin Danziger, BS, ABI – Colorado Asbestos Inspector Certification # 12781
Indoor Environmental Services, Inc.
970-390-0087
ColoradoAsbestos.com
EMSL Analytical, Inc.
1010 Yuma Street, Denver, CO 80204
Phone/Fax:(303) 740-5700 / (303) 741-1400
http://www.emsl.com denverlab@emsl.com
221201636
CustomerID:INES78
CustomerPO:
ProjectID:
EMSL Order:
Attn:Quentin Danziger
Q Consulting, Inc.
PO Box 997
Vail, CO 81658
Received:05/10/12 10:25 AM
Coldstream 20
Fax:
Phone:(970) 390-0087
Project:
5/10/2012Analysis Date:
Collected:5/9/2012
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA
600/M4-82-020 Method(s) using Polarized Light Microscopy
01-01-Texture
221201636-0001
Sheetrock / Joint
Compound
White None Detected
Inseparable paint / coating layer included in analysis
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
01-01-Tape
221201636-0001A
Sheetrock / Joint
Compound
White None Detected
Fibrous
Homogeneous
Cellulose100%Non-fibrous (other)0%
01-01-Joint
Compound
221201636-0001B
Sheetrock / Joint
Compound
White None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
01-01-Drywall
221201636-0001C
Sheetrock / Joint
Compound
Brown/White None Detected
Fibrous
Heterogeneous
Cellulose10%
Glass3%
Non-fibrous (other)87%
01-02-Texture
221201636-0002
Sheetrock / Joint
Compound
White None Detected
Inseparable paint / coating layer included in analysis
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
01-02-Tape
221201636-0002A
Sheetrock / Joint
Compound
White None Detected
Fibrous
Homogeneous
Cellulose100%Non-fibrous (other)0%
01-02-Joint
Compound
221201636-0002B
Sheetrock / Joint
Compound
White None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
1Test Report PLM-7.16.0 Printed: 5/10/2012 3:54:33 PM
Erin Orthun, Laboratory Manager
or other approved signatory
Analyst(s)
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no
responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim
product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL
recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless
requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. None Detected = <1%
Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0
Initial report from 05/10/2012 15:54:33
Donna Nading (7)
Molly Walker (14)
EMSL Analytical, Inc.
1010 Yuma Street, Denver, CO 80204
Phone/Fax:(303) 740-5700 / (303) 741-1400
http://www.emsl.com denverlab@emsl.com
221201636
CustomerID:INES78
CustomerPO:
ProjectID:
EMSL Order:
Attn:Quentin Danziger
Q Consulting, Inc.
PO Box 997
Vail, CO 81658
Received:05/10/12 10:25 AM
Coldstream 20
Fax:
Phone:(970) 390-0087
Project:
5/10/2012Analysis Date:
Collected:5/9/2012
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA
600/M4-82-020 Method(s) using Polarized Light Microscopy
01-02-Drywall
221201636-0002C
Sheetrock / Joint
Compound
Brown/White None Detected
Fibrous
Heterogeneous
Cellulose10%
Glass3%
Non-fibrous (other)87%
01-03-Texture
221201636-0003
Sheetrock / Joint
Compound
White None Detected
Inseparable paint / coating layer included in analysis
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
01-03-Tape
221201636-0003A
Sheetrock / Joint
Compound
White None Detected
Fibrous
Homogeneous
Cellulose100%Non-fibrous (other)0%
01-03-Joint
Compound
221201636-0003B
Sheetrock / Joint
Compound
White None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
01-03-Drywall
221201636-0003C
Sheetrock / Joint
Compound
Brown/White None Detected
Fibrous
Heterogeneous
Cellulose10%
Glass3%
Non-fibrous (other)87%
02-01
221201636-0004
Texture White None Detected
Inseparable paint / coating layer included in analysis
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
02-02
221201636-0005
Texture White None Detected
Inseparable paint / coating layer included in analysis
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
2Test Report PLM-7.16.0 Printed: 5/10/2012 3:54:33 PM
Erin Orthun, Laboratory Manager
or other approved signatory
Analyst(s)
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no
responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim
product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL
recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless
requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. None Detected = <1%
Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0
Initial report from 05/10/2012 15:54:33
Donna Nading (7)
Molly Walker (14)
EMSL Analytical, Inc.
1010 Yuma Street, Denver, CO 80204
Phone/Fax:(303) 740-5700 / (303) 741-1400
http://www.emsl.com denverlab@emsl.com
221201636
CustomerID:INES78
CustomerPO:
ProjectID:
EMSL Order:
Attn:Quentin Danziger
Q Consulting, Inc.
PO Box 997
Vail, CO 81658
Received:05/10/12 10:25 AM
Coldstream 20
Fax:
Phone:(970) 390-0087
Project:
5/10/2012Analysis Date:
Collected:5/9/2012
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA
600/M4-82-020 Method(s) using Polarized Light Microscopy
02-03
221201636-0006
Texture White None Detected
Inseparable paint / coating layer included in analysis
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
03-01-Paint
221201636-0007
External Building
Paper
Olive None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
03-01-Paper
221201636-0007A
External Building
Paper
White None Detected
Fibrous
Homogeneous
Synthetic100%Non-fibrous (other)0%
03-02-Paint
221201636-0008
External Building
Paper
Olive None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
03-02-Paper
221201636-0008A
External Building
Paper
White None Detected
Fibrous
Homogeneous
Synthetic100%Non-fibrous (other)0%
03-03-Paint
221201636-0009
External Building
Paper
Olive None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
03-03-Paper
221201636-0009A
External Building
Paper
White None Detected
Fibrous
Homogeneous
Synthetic100%Non-fibrous (other)0%
3THIS IS THE LAST PAGE OF THE REPORT.Test Report PLM-7.16.0 Printed: 5/10/2012 3:54:33 PM
Erin Orthun, Laboratory Manager
or other approved signatory
Analyst(s)
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no
responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim
product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL
recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless
requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. None Detected = <1%
Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0
Initial report from 05/10/2012 15:54:33
Donna Nading (7)
Molly Walker (14)