Loading...
HomeMy WebLinkAboutF12-0023 APP AND PLANSBy David Rhoades at 3:30 pm, May 18, 2012 PRJ12-0029 B12-0021 F12-0023 By David Rhoades at 3:30 pm, May 18, 2012 The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Bu l l e t i n 0 3 4 Re v . A Bulletin 034 Rev. A Model G5-56 Model G5-42 Quick Response Concealed Automatic Sprinkler UL Quick Response FM Standard Response Concealed Sprinkler With a 3/4” (19mm) Adjustment Features 1. Cover plate attachment (Plain or Perforated) with ¾” (19mm) assembly adjustment. 2. Smooth aesthetic ceiling profile. 3. Factory installed protective cap. 4. Available in brass, chrome or black plated and white painted finishes. 5. Ordinary and Intermediate temperature rating. For K2.8 & additional Sprinklers refer to Bulletin 154 for Technical Specifi cation and Approvals Approvals & Listings 1. Underwriters Laboratories Inc. and cULus - Quick Response 2. Factory Mutual Research Corp. (FM) - Standard Response (See Page 3) • Light Hazard Occupancies - No Limitations • Ordinary Hazard Occupancies Groups 1 & 2 Wet Systems Only U.S. Patent number 6,554,077. Product Description The Reliable Model G5-56 and G5-42 uses a proven quick response fusible element in a standard style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate assembly. The threaded engagement provides ¾” (19mm) of cover adjust- ment. The flat cover plate is attached to the skirt using either 135°F (57°C) or 165°F (74°C) ordinary temperature classifica- tion solder. When the ceiling temperature rises, the solder holding the flat cover plate melts, the flat cover plate released thus expos- ing the sprinkler inside to the rising ambient temperature. The subsequent fusing of the element opens the waterway and causes the deflector to distribute the water. Any secure engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. Application The Reliable Model G5-56 and G5-42 are the most versatile quick response concealed sprinklers available. It provides the best form of fire protection while offering an attractive ap- pearance and 3/4” (19mm) of cover adjustment for ease of installation. The small diameter cover plate assembly is eas- ily attached and blends into the ceiling, concealing the most dependable fire protection available, an automatic sprinkler system. The Model G5-56 and G5-42 are designed for use where aesthetic appearance is important. Offices, hospitals, motels and restaurants are but a few of the applications where it can be used. The Model G5-56 and G5-42 is a UL Listed Quick Response Concealed sprinklers intended for use in accordance with NFPA 13. FM Approves the G5-56 sprinkler as a standard re- sponse concealed sprinkler intended for use in accordance with FM Loss Prevention Data Sheet 2.0. Plain Cover Plate Perforated Cover Plate Installation Do not install the G5-56 and G5-42 in ceilings which have positive pressure in the space above. • Cut a 25/8” inch (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model FC Wrench. The wrench has a socket drive which is inserted into the body of the sprinkler. When installing a sprinkler the wrench is first positioned into the sprinkler/cup assembly until the wrench socket engages the body of the sprinkler. The sprinkler is then tightened into the pipe fitting. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/ CUP ASSEMBLY. Install the cover plate by hand turning the cover in the clockwise direction until it is tight against the ceil- ing. A protective cap is provided to protect the drop-down sprinkler deflector from damage which could occur during construction before the cover plate is installed. The cap is factory installed inside the sprinkler cup. Remove cap to install sprinkler, then re- install cap until the cover plate is installed. Maintenance The Model G5-56 and G5-42 should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick re- placement of damaged or operated sprinklers. Prior to installa- tion, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. UL Listing Category Sprinklers, Automatic and Open Quick Response Sprinkler UL Guide Number VNIV Maximum Working Pressure 175 psi (12 bar) 100% Factory tested Hydrostatically to 500 psi (34.5 bar) Temperature Rating Classifi cationSprinkler Cover Plate Max. Ambient Temp. Ordinary165°F/74°C135°F/57°C100°F/38°C Intermediate212°F/100°C165°F/74°C150°F/66°C Model FC Sprinkler Wrench Ordering Information 1. Sprinkler Model 2. Nominal Orifice 3. Flat Cover Plate Plain or Perforated 4. Flat Cover Plate Assembly Finish 5. Inlet Type Cover Plate Finishes(1) Standard Finishes Chrome White Paint Special Application Finishes(2) Bright Brass Finished Bronze Black Plating Black Paint Off White Satin Chrome (1) Other finishes and colors are available on special order. Consult factory for details. Coverplate custom paint is semi-gloss, unless specified otherwise. (2) For the perforated style cover- plate, consult factory for avail- ability on these and other cus- tom finishes. 2. Technical Data Sprinkler Inlet Total Adjustment Nominal Orifi ce Nominal K Factor ThreadApprovals Sprinkler Identifi cation (SIN)USMetric Non Adjustable¾” (19mm)½” (15mm)5.680½” NPT (R½)1,2RA3415 Non Adjustable¾” (19mm)7/16” (10mm)4.260½” NPT (R½)1RA3413 Notice FOR USE AS A REPLACEMENT OF MODEL G4A SPRINKLERS NOTE: 1. Testing has shown that use of a “nipple extension” will not affect the listing of the sprinkler. 2. For RETROFIT installations, per NFPA 13 (2010) section 8.15.19.4, “which allows the use of nipples as the same pipe thread size as the existing outlet when revamping existing systems”. 3. Do not exceed 8-18 ft-lbs of torque during installation. 3. The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 04/12 P/N 9999970421 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Reliable...For Complete Protection The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F1FR56 Series Quick Response Standard Spray Bu l l e t i n 0 1 4 R e v . G Bulletin 014 Rev. G Model F1FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model F1FR56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Horizontal Sidewall Model F1FR56 Concealed Sprinkler Types Standard Pendent Listing & Approvals 1. Underwriters Laboratories Inc. and Certified for Canada (cULus). 2. Factory Mutual Approvals (FM) 3. Loss Prevention Council (LPCB, UK) 4. VdS Schadenverhütung GmbH UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Product Description Reliable Models F1FR56 Series Sprinklers are quick re- sponse sprinklers which combine the durability of a stan- dard sprinkler with the attractive low profile of a decorative sprinkler. The Models F1FR56 Series Recessed automatic sprin- klers utilize a 3.0 mm frangible glass bulb. These sprin- klers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1FR56 Series sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manu- factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Pendent Conventional Recessed Pendent/F1/F2 Upright Application Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflec- tor style and sprinkler type are in accordance with the lat- est published standards of the National Fire Protection As- sociation or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. Vertical Sidewall Horizontal Sidewall Recessed Horizontal Sidewall Recessed Pendent/FP Concealed Pendent 2. Pendent ConventionalUpright Model F1FR56 Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifi ce Thread Size Nominal K Factor Sprinkler Height Approval Organization Sprinkler Identifi cation Number (SIN) USMetricUprightPendent Standard-Upright (SSU) and pendent Deflectors Marked to Indicate Position ½” (15mm)½” NPT(R½) 5.6802.25” (57mm)1, 2, 3, 4RA1425(1)RA1414 (1)(2) Conventional-Install in Upright or Pendent Position 15mm(1)½” NPT(R½) 5.68057mm3,4RA1475 (1) cULus listed corrosion resistant (Polyester coated) sprinkler. (2) Polyester coated FM approved sprinkler. Model F1FR56/F1 or F2 Model F1FR56 Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifi ce Thread Size K Factor Sprinkler Height Sprinkler Identifi cation Number (SIN)USMetric ½” (15mm)½” NPT(R½)5.6802.25” (57mm)RA1414 (1) Refer to escutcheon data table for approvals and dimensions. Model F1FR56/FP 3. Model F1FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Orifi ce Thread Size Nominal K Factor Sprinkler Height Approval Organizations Sprinkler Identifi cation Numbers (SIN)USMetric ½” (15mm)½” NPT (R1/2)5.68.02.25” (57mm)1,2,3,4 RA1485(2) 15mm½” NPT (R1/2)5.68.02.25” (57mm)4(1) (1) LPC Approval is for pendent position only. (2) cULus Listed corrosion resistant (Polyester coated) sprinkler. Sprinkler TypeDefl ector to Ceiling Distance (Min. - Max.) Upright4” (102mm) - 12” (305mm) Pendent4” (102mm) - 12” (305mm) Model F1FR56 Quick Response Horizontal Sidewall Sprinkler Defl ector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal Orifi ceThread Size Nominal K Factor Sprinkler Height Approval Organizations and Type of Approval Sprinkler Identifi cation Numbers (SIN)USMetricLight Hazard Ordinary Hazard ½” (15mm)½” NPT (R1/2)5.6802.63” (67mm)1,21RA1435(1) (1) cULus Listed corrosion resistant (Polyester coated) sprinkler. Horizontal Sidewall Vertical Sidewall Note: For Recessed HSW Sprinklers use installation wrench GFR2. Model F1FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal Orifi ce “K” Factor Thread Size Model Temp. RatingMax. Ambient Temp Bulb Color Approvals Sprinkler Identifi cation Number(SIN)USMetricSprinklerCover ½” (15mm)5.680½” NPTF1FR135°F/57°C135°F/57°C100°F/38°COrange1RA1414 ½” (15mm)5.680½” NPTF1FR155°F/68°C135°F/57°C100°F/38°CRed1, 4(1)RA1414 ½” (15mm)5.680½” NPTF1FR175°F/79°C165°F/74°C100°F/38°CYellow1RA1414 ½” (15mm)5.680½” NPTF1FR200°F/93°C165°F/74°C150°F/65°CGreen1RA1414 (1) For VdS only = 155°F/68°C Norbulb and 1/2” [12,7mm] adjustment. Figure 1 Figure 2 Installation Aid A protective cap is included for use during installation. Important: The F1FR56 Sprinkler with Model CCP cover plate is not an FM Approved combination. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard response sprinklers should not be intermixed. The Model F1FR56 Recessed Quick Response Sprin- klers are to be installed as shown. The Model F1 or F2 Es- cutcheons illustrated are the only recessed escutcheons to be used with the Model F1FR56 Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. When installing Model F1FR56 Sprinklers, use the Mod- el D Sprinkler Wrench. Use the Model GFR2 Wrench for installing F1FR56 Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. NOTE: A leak tight ½” NPT (R1/2) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprin- klers. The Model F1FR56/ CCP Concealed Sprinkler uses the ½” orifice, ½” NPT (R1/2), 135°F (57°C), 155°F (68°C), 175°F (79°C) or 200°F (93°C) Model F1FR56 Pendent Sprinkler with a threaded Model CCP cup which is fac- tory attached to the sprinkler. The assembly is complet- ed by the installation of the attractive, low profile, 135°F (57°C) or 165°F (74°C) rated Model CCP push on cover plate assembly. The cover plate and sprinkler cup as- semblies are joined using a cover plate skirt with flexible tabs for threaded engagement. A choice of two cover plate assemblies provide either ½” (13mm) or 5/16” (8mm) of cover adjustment. Do not install these sprinklers in ceiling which have positive pressure in the space above. After a 25/8” (67mm) diameter hole is cut in the ceil- ing, the sprinkler is easily installed with the Model RC1 Wrench. A Teflon* based thread sealant should be applied to the sprinkler threads only. The Model RC1 Wrench is then used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate is then pushed onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter clockwise direction. 4. *DuPont Registered Trade Mark 5. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other con- cealed cover plate/cup assembly with the Model F1FR56 Pendent Sprinkler or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Temperature Ratings Classifi cation Sprinkler Temperature Max. Ambient Temp.Bulb Color °C°F Ordinary Ordinary Intermediate Intermediate High (1) 57 68 79 93 141 135 155 175 200 286 100°F (38°C) 100°F (38°C) 150°F (66°C) 150°F (66°C) 225°F (107°C) Orange Red Yellow Green Blue (1) Not available for recessed sprinklers. Escutcheon Data (1) Escutcheon Model ApprovalsAdjustment “A” Dimension Face of Fitting to Ceiling or Wall Dimension F11, 3, 4 Max Recess Min Recess 1½” (38.1mm) 3/4” (19.1mm) 3/16” - 15/16” (5mm - 24mm) F21, 2, 3, 4 Max Recess Min Recess 1 ½” (38.1mm) 1” (25mm) 3/16” - 11/16” (5mm - 17mm) FP Push-on/ Thread-off 1, 4 Max Recessed Min Recessed 7/16” (11mm) 15/16 (24mm) 11/2” (38.1mm) 1” (25.4mm) (1) SIN RA1435 – cULus permits use with F1, F2 or FP escutcheons for “light hazard” only, while FM limits use for same hazard with F2 escutcheon only. Maintenance The Models F1FR56 and F1FR56 Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be main- tained to allow quick replacement of damaged or oper- ated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to mini- mize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal sidewall Concealed pendent Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finishes (1) Standard Finishes SprinklerEscutcheonCover plate Bronze Chrome Plated Polyester Coated (4)(5) Brass Chrome Plated White Painted Chrome White Special Application Finishes SprinklerEscutcheonCover plate Bright Brass (3) Black Plated Black Paint (2) Off White (2) Satin Chrome Bright Brass Black Plated Black Paint Off White Satin Chrome Bright Brass Satin Off White Black Paint Black Plated (1) Other finishes and colors are available on special order. Consult the factory for details. (2) cULus Listed only. (3) 200°F (93°C) maximum. (4) cULus listed “corrosion resistance” applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright) and RA1414 (Pendent) in standard black or white. (5) FM Approvals finish as “Polyester coated” applies to SIN Number RA1414 (Pendent) in standard black or white. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Deflector Type 5. Temperature Rating 6. Sprinkler Finish 7. Escutcheon Type 8. Escutcheon Finish (where applicable) 9. Cover plate Model 10. Cover plate Thread size 11. Cover plate Temperature 12. Cover plate Adjustment 13. Cover plate Finish Note: When Model F1FR56 Recessed sprinklers are ordered, the sprin- klers and escutcheons are packaged separately. The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A 08/11 P/N 9999970300 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Reliable...For Complete Protection