Loading...
HomeMy WebLinkAboutF12-0011 PLANS APPROVEDCastle Fire Sprinklers, INC. 970-688-0789 CO#938 P.O. Box 3878, Avon, CO 81620 castlefiresprinkler@yahoo.com To whom it may concern, Castle Fire Sprinklers is requesting a permit to m odify the existing fire sprinkler system located in Unit 204 of the Antlers Lodge in Vail Colorado i n order to accommodate tenant improvement. The work needed to be performed is the relocation of fo ur automatic sprinkler heads. The piping to be use d will match existing type M copper tube sized equal to the existing pipe with the exception of the exis ting ¾” pipe where 1” pipe will be used. The sprinkler c overage will not exceed the original design requirements. Due to previous projects in this buil ding with similar requirements (unit 605) no calculations are provided. The address to the Antle rs Lodge is 680 West Lionshead Place, Vail, CO 8165 7. If you have any questions or comments regarding thi s project please feel free to contact Stuart Thompson with Castle fire Sprinklers at 970-688-078 9. Thank you for your consideration. Eric Schumacher Castle Fire Sprinklers 720-281-2364 General Description TheTyco ®RapidResponse™,Series LFII(TY2334)ResidentialHorizontal SidewallSprinklersaredecorative,fastresponse,frangiblebulbsprin-klersdesignedforuseinresidential occupanciessuchashomes,apart-ments,dormitories,andhotels.When aestheticsandoptimizedflowcharac-teristicsarethemajorconsideration,theSeriesLFII(TY2334)shouldbethe firstchoice.TheSeriesLFIIaretobeusedinwet piperesidentialsprinklersystemsfor one-andtwo-familydwellingsandmo-bilehomesperNFPA13D;wetpipe residentialsprinklersystemsforresi-dentialoccupanciesuptoandinclud-ingfourstoriesinheightperNFPA 13R;or,wetpipesprinklersystemsfor theresidentialportionsofanyoccu-pancyperNFPA13.TheSeriesLFII(TY2334)hasa4.4 (63,4)K-factorthatprovidesthere-quiredresidentialflowratesatreduced pressures,enablingsmallerpipesizes andwatersupplyrequirements.TherecessedversionoftheSeries LFII(TY2334)isintendedforusein areaswithfinishedwalls.Itemploysa two-pieceStyle20RecessedEscutch-eon.TheRecessedEscutcheonpro-vides1/4inch(6,4mm)ofrecessed adjustmentorupto1/2inch(12,7mm)oftotaladjustmentfromtheflush mountingsurfaceposition.Theadjust-mentprovidedbytheRecessedEs-cutcheonreducestheaccuracyto whichthepipenipplestothesprinklers mustbecut.TheSeriesLFII(TY2334)hasbeen designedwithheatsensitivityand waterdistributioncharacteristics proventohelpinthecontrolofresiden-tialfiresandtoimprovethechancefor occupantstoescapeorbeevacuated.WARNINGS TheSeriesLFII(TY2334)Residential HorizontalSidewallSprinklersde-scribedhereinmustbeinstalledand maintainedincompliancewiththis document,aswellaswiththeapplica-blestandardsoftheNationalFirePro-tectionAssociation,inadditiontothe standardsofanyotherauthoritieshav-ingjurisdiction.Failuretodosomay impairtheperformanceofthesede-vices.Theownerisresponsibleformaintain-ingtheirfireprotectionsystemandde-vicesinproperoperatingcondition.Theinstallingcontractororsprinkler manufacturershouldbecontacted withanyquestions.Sprinkler/Model Identification Number SINTY2334 Page1of6 TFP412 DECEMBER,2007 SeriesLFIIResidential HorizontalSidewallSprinklers 4.4K-factor TechnicalServices:Tel:(800)381-9312/Fax:(800)791-5500 IMPORTANT AlwaysrefertoTechnicalData SheetTFP700forthe“INSTALLER WARNING”thatprovidescautions withrespecttohandlingandinstal-lationofsprinklersystemsandcom-ponents.Improperhandlingandin-stallationcanpermanentlydamage asprinklersystemoritscompo-nentsandcausethesprinklertofail tooperateinafiresituationorcause ittooperateprematurely. Page2of6 TFP412 FIGURE1 SERIESLFII(TY2334)RESIDENTIAL HORIZONTALSIDEWALLANDRECESSEDHORIZONTALSIDEWALLSPRI NKLERS FIGURE2 STYLE20RECESSEDESCUTCHEON FORUSEWITHTHESERIESLFII(TY2334)RESIDENTIALHORIZONTALSIDEWALLSPRINKLER Sealing -3 5 4 *6 Compression ofDeflector.isindicatedontop Temperaturerating Bulb Deflector ---*1 Components:2Button Frame --WRENCH STYLE20 RECESSED ESCUTCHEON FLATS 2-7/8"DIA.RECESSED (73,0mm)5 NOMINAL PLATESEATING SURFACE ESCUTCHEON MAKE-IN CENTERLINE OFWATERWAY 7/16"(11,1mm)(54,0mm)(38,1mm)DEFLECTOR BOSS (11,1mm)7/16"END-OF-2-1/8"1-1/2"DEFLECTOR TOP-OF-4 2 6 *1 3 Assembly Screw TOP 1/2"NPT FLATS WRENCH 1-1/4"(31,8mm)1"(25,4mm)MOUNTING PLATE TY2334 MOUNTING SURFACE CLOSURE (73,0mm)1/2"(12,7mm)(57,2mm)2-1/4"DIA.1/4"(6,4mm)1/8"(3,2mm)(11,1±3,2mm)SPRINKLER FITTING FACEOF 7 /16±1 /8"2-7/8"DIA.BOSS END-OF-DEFLECTOR TOP-OF-DEFLECTOR 7/16"(11,1mm)FIGURE3 W-TYPE6SPRINKLERWRENCH FIGURE4 W-TYPE7RECESSED SPRINKLERWRENCH WRENCH RECESS (END "A"USED FORTY2334)RECESS WREN C H WITHSPRINKLER ENGAGEMENT IN TOENSURE WREN C HIN G AREA PUSHWRENCH Technical Data Approvals:ULandC-ULListed.MaximumWorkingPressure:175psi(12,1bar)DischargeCoefficient:K=4.4GPM/psi 1/2 (63,4LPM/bar 1/2 )TemperatureRating:155°F/68°Cor175°F/79°C Finishes:WhitePolyesterCoated,ChromePlated,orNaturalBrass PhysicalCharacteristics:Frame..............Brass Button.............Bronze SealingAssembly...............BerylliumNickelw/Teflon†Bulb.........3mmdia.Glass CompressionScrew.....Bronze Deflector...........Copper †DupontRegisteredTrademark Operation TheglassBulbcontainsafluidthat expandswhenexposedtoheat.When theratedtemperatureisreached,the fluidexpandssufficientlytoshatterthe glassBulballowingthesprinklerto activateandflowwater.Design Criteria TheTyco ®RapidResponse™,Series LFII(TY2334)ResidentialHorizontal SidewallSprinklersareULandC-UL Listedforinstallationinaccordance withthefollowingcriteria.NOTE Whenconditionsexistthatareoutside thescopeoftheprovidedcriteria,refer totheResidentialSprinklerDesign GuideTFP490forthemanufacturer’s recommendationsthatmaybeaccept-abletothelocalAuthorityHavingJu-risdiction.SystemType.Onlywetpipesystems maybeutilized.HydraulicDesign.Theminimumre-quiredsprinklerflowrateforsystems designedtoNFPA13DorNFPA13R aregiveninTableA,B,C,andDasa functionoftemperatureratingandthe maximumallowablecoverageareas.Thesprinklerflowrateistheminimum requireddischargefromeachofthe totalnumberof“designsprinklers”as specifiedinNFPA13DorNFPA13R.ForsystemsdesignedtoNFPA13,the numberofdesignsprinklersistobe thefourmosthydraulicallydemanding sprinklers.Theminimumrequireddis-chargefromeachofthefoursprinklers istobethegreaterofthefollowing:•TheflowratesgiveninTablesA,B,C,andDforNFPA13Dand13Ras afunctionoftemperatureratingand themaximumallowablecoverage area.•Aminimumdischargeof0.1gpm/sq.ft.overthe“designarea”comprised ofthefourmosthydraulicallyde-mandingsprinklersfortheactual coverageareasbeingprotectedby thefoursprinklers.ObstructionToWaterDistribution.Locationsofsprinklersaretobein accordancewiththeobstructionrules ofNFPA13forresidentialsprinklers.OperationalSensitivity.Thesprin-klersaretobeinstalledwithanend-of-deflector-bosstowalldistanceof1-3/8to6inchesorintherecessedpo-sitionusingonlytheStyle20Re-cessedEscutcheonasshownin Figure2.Inadditionthetop-of-deflector-to-ceil-ingdistanceistobewithintherange (Ref.TableA,B,C,orD)beinghy-draulicallycalculated.SprinklerSpacing.Theminimum spacingbetweensprinklersis8feet (2,4m).Themaximumspacingbe-tweensprinklerscannotexceedthe widthofthecoveragearea(Ref.Table A)beinghydraulicallycalculated(e.g.,maximum12feetfora12ft.x12ft.coveragearea,or16feetfora16ft.x 20ft.coveragearea).Installation TheSeriesLFII(TY2334)mustbein-stalledinaccordancewiththefollow-inginstructions:NOTES Donotinstallanybulbtypesprinklerif thebulbiscrackedorthereisalossof liquidfromthebulb.Withthesprinkler heldhorizontally,asmallairbubble shouldbepresent.Thediameterofthe airbubbleisapproximately1/16inch (1,6mm).A1/2inchNPTsprinklerjointshould beobtainedwithaminimumtomaxi-mumtorqueof7to14ft.lbs.(9,5to 19,0Nm).Higherlevelsoftorquemay distortthesprinklerinletwithconse-quentleakageorimpairmentofthe sprinkler.Donotattempttocompensateforin-sufficientadjustmentinanEscutcheon Platebyunder-orover-tighteningthe Sprinkler.Readjustthepositionofthe sprinklerfittingtosuit.TheSeriesLFIIHorizontalSidewall Sprinklers mustbeinstalledinac-cordancewiththefollowinginstruc-tions.Step1.Horizontalsidewallsprinklers aretobeinstalledinthehorizontal positionwiththeircenterlineofwater-wayperpendiculartothebackwalland paralleltotheceiling.Theword“TOP”ontheDeflectoristofacetowardsthe ceilingwiththefrontedgeoftheDe-flectorparalleltotheceiling.Step2.Withpipethreadsealantap-pliedtothepipethreads,handtighten thesprinklerintothesprinklerfitting.Step3.Tightenthesprinklerintothe sprinklerfittingusingonlytheW-Type 6SprinklerWrench(Ref.Figure3).WithreferencetoFigure1,theW-Type 6SprinklerWrenchistobeappliedto thewrenchflats.The SeriesLFIIRecessedHorizontal SidewallSprinklers mustbeinstalled inaccordancewiththefollowingin-structions.StepA.Recessedhorizontalsidewall sprinklersaretobeinstalledinthe horizontalpositionwiththeircenterline ofwaterwayperpendiculartotheback wallandparalleltotheceiling.The word“TOP”ontheDeflectoristoface towardstheceiling.StepB.AfterinstallingtheStyle20 MountingPlateoverthesprinkler threadsandwithpipethreadsealant appliedtothepipethreads,hand tightenthesprinklerintothesprinkler fitting.StepC .Tightenthesprinklerintothe sprinklerfittingusingonlytheW-Type 7RecessedSprinklerWrench(Ref.Figure4).WithreferencetoFigure1,theW-Type7RecessedSprinkler Wrenchistobeappliedtothesprinkler wrenchflats.StepC.Afterthewallhasbeenin-stalledorthefinishcoathasbeenap-plied,slideontheStyle20Closure overtheSeriesLFIISprinklerand pushtheClosureovertheMounting Plateuntilitsflangecomesincontact withthewall.TFP412 Page3of6 (ContinuedonPage8) Page4of6 TFP412 (a)Forcoverageareadimensionslessthanorbetweenthosei ndicated,itisnecessarytousetheminimumrequiredflowfo rthenext highestcoverageareaforwhichhydraulicdesigncriteriaa restated.(b)Width(backwallwheresprinklerislocated)xLength(ho rizontalthrowofsprinkler).(c)RequirementisbasedonminimumflowinGPM(LPM)fromeac hsprinkler.Theassociatedresidualpressuresarecalcula tedusing thenominalK-factor.RefertoHydraulicDesignCriteriaSe ctionfordetails.(d)Sidewallsprinklers,whereinstalledunderaceilingwi thaslopegreaterthan0inchrisefora12inchruntoaslopeup to2inch risefor12inchrun,mustbelocatedperoneofthefollowing:•Locatethesprinklersatthehighpointoftheslopeandposit ionedtodischargedowntheslope.•Locatethesprinklersalongtheslopeandpositionedtodisc hargeacrosstheslope.TABLEA NFPA13DANDNFPA13RWETPIPEHYDRAULICDESIGNCRITERIA FORTHESERIESLFII(TY2334)RESIDENTIALHORIZONTALSIDEWALLANDRECESSEDHORIZONTALS IDEWALLSPRINKLERS FORHORIZONTALCEILING(Maximum2InchRisefor12InchRun)12x12 (3,7x3,7)Maximum Coverage Area (a)WidthxLength (b)Ft.xFt.(mxm)MinimumFlow (c)andResidualPressure 14x14 (4,3x4,3)16x16 (4,9x4,9)16x18 (4,9x5,5)16x20 (4,9x6,1)14GPM(53,0LPM)10.1psi(0,70bar)16GPM(60,6LPM)13.2psi(0,91bar)19GPM(71,9LPM)18.6psi(1,28bar)23GPM(87,1LPM)27.3psi(1,88bar)13GPM(49,2LPM)8.7psi(0,60bar)155°F/68°C Top-Of-Deflector-To-Ceiling:4to6Inches(100to150mm)175°F/79°C Top-Of-Deflector-To-Ceiling:6to12Inches(150to300mm)155°F/68°C 175°F/79°C 13GPM(49,2LPM)8.7psi(0,60bar)14GPM(53,0LPM)10.1psi(0,70bar)16GPM(60,6LPM)13.2psi(0,91bar)19GPM(71,9LPM)18.6psi(1,28bar)23GPM(87,1LPM)27.3psi(1,88bar)12 (3,7)14 (4,3)16 (4,9)16 (4,9)16 (4,9)Maximum Spacing Ft.(m)18x18 (5,5x5,5)18 (5,5)18x20 (5,5x6,1)18 (5,5)26GPM(98,4LPM)34.9psi(2,41bar)13GPM(49,2LPM)8.7psi(0,60bar)13GPM(49,2LPM)8.7psi(0,60bar)14GPM(53,0LPM)10.1psi(0,70bar)14GPM(53,0LPM)10.1psi(0,70bar)17GPM(64,3LPM)14.9psi(1,03bar)17GPM(64,3LPM)14.9psi(1,03bar)20GPM(75,7LPM)20.7psi(1,43bar)20GPM(75,7LPM)20.7psi(1,43bar)23GPM(87,1LPM)27.3psi(1,88bar)23GPM(87,1LPM)27.3psi(1,88bar)23GPM(87,1LPM)27.3psi(1,88bar)23GPM(87,1LPM)27.3psi(1,88bar)23GPM(87,1LPM)27.3psi(1,88bar)23GPM(87,1LPM)27.3psi(1,88bar)26GPM(98,4LPM)34.9psi(2,41bar)26GPM(98,4LPM)34.9psi(2,41bar)26GPM(98,4LPM)34.9psi(2,41bar)ELEVATI O N TFP412 Page5of6 (a)Forcoverageareadimensionslessthanorbetweenthosei ndicated,itisnecessarytousetheminimumrequiredflowfo rthenext highestcoverageareaforwhichhydraulicdesigncriteriaa restated.(b)Width(backwallwheresprinklerislocated)xLength(ho rizontalthrowofsprinkler).(c)RequirementisbasedonminimumflowinGPM(LPM)fromeac hsprinkler.Theassociatedresidualpressuresarecalcula tedusing thenominalK-factor.RefertoHydraulicDesignCriteriaSe ctionfordetails..TABLEB NFPA13DANDNFPA13RWETPIPEHYDRAULICDESIGNCRITERIA FORTHESERIESLFII(TY2334)RESIDENTIALHORIZONTALSIDEWALLANDRECESSEDHORIZONTALS IDEWALLSPRINKLERS FORSPRINKLERSATTHEHIGHPOINTOFTHESLOPEANDDISCHARGING DOWNTHESLOPE (GreaterThan2InchRisefor12InchRunUpTo8InchRisefor12 InchRun)12x12 (3,7x3,7)Maximum Coverage Area (a)WidthxLength (b)Ft.xFt.(mxm)14x14 (4,3x4,3)16x16 (4,9x4,9)16x18 (4,9x5,5)16x20 (4,9x6,1)12 (3,7)14 (4,3)16 (4,9)16 (4,9)16 (4,9)Maximum Spacing Ft.(m)23GPM(87,1LPM)27,3psi(1,88bar)MinimumFlow (c)andResidualPressure (I )Twosprinklerdesignwiththesprinklersatthehighpointo ftheslopeandpositioned todischargedowntheslope.Top-Of-Deflector-To-Ceiling:4to6Inches(100to150mm)Top-Of-Deflector-To-Ceiling:6to12Inches(150to300mm)155°F/68°C 175°F/79°C 155°F/68°C 175°F/79°C I I I I I I I I I I I I I I I I I I I I 18x18 (5,5x5,5)18 (5,5)18x20 (5,5x6,1)18 (5,5)23GPM(87,1LPM)27,3psi(1,88bar)23GPM(87,1LPM)27,3psi(1,88bar)23GPM(87,1LPM)27,3psi(1,88bar)I 23GPM(87,1LPM)27,3psi(1,88bar)I 23GPM(87,1LPM)27,3psi(1,88bar)I 23GPM(87,1LPM)27,3psi(1,88bar)23GPM(87,1LPM)27,3psi(1,88bar)I I 26GPM(98,4LPM)34.9psi(2,41bar)I 26GPM(98,4LPM)34.9psi(2,41bar)I 26GPM(98,4LPM)34.9psi(2,41bar)26GPM(98,4LPM)34.9psi(2,41bar)I 23GPM(87,1LPM)27,3psi(1,88bar)23GPM(87,1LPM)27,3psi(1,88bar)23GPM(87,1LPM)27,3psi(1,88bar)23GPM(87,1LPM)27,3psi(1,88bar)23GPM(87,1LPM)27,3psi(1,88bar)23GPM(87,1LPM)27,3psi(1,88bar)23GPM(87,1LPM)27,3psi(1,88bar)23GPM(87,1LPM)27,3psi(1,88bar)23GPM(87,1LPM)27,3psi(1,88bar)23GPM(87,1LPM)27,3psi(1,88bar)23GPM(87,1LPM)27,3psi(1,88bar)23GPM(87,1LPM)27,3psi(1,88bar)23GPM(87,1LPM)27,3psi(1,88bar)23GPM(87,1LPM)27,3psi(1,88bar)23GPM(87,1LPM)27,3psi(1,88bar)23GPM(87,1LPM)27,3psi(1,88bar)ELEVATI O N MAXIMUM 8"12" Careand Maintenance TheTyco ®RapidResponse™,Series LFII(TY2334)mustbemaintainedand servicedinaccordancewiththefollow-inginstructions:NOTES AbsenceofanEscutcheonPlatemay delaythesprinkleroperationinafire situation.Beforeclosingafireprotectionsystem maincontrolvalveformaintenance workonthefireprotectionsystem whichitcontrols,permissiontoshut downtheaffectedfireprotectionsys-temmustbeobtainedfromtheproper authoritiesandallpersonnelwhomay beaffectedbythisactionmustbeno-tified.Sprinklerswhicharefoundtobeleak-ingorexhibitingvisiblesignsofcorro-sionmustbereplaced.Automaticsprinklersmustneverbe painted,plated,coated,orotherwise alteredafterleavingthefactory.Modi-fiedsprinklersmustbereplaced.Sprinklersthathavebeenexposedto corrosiveproductsofcombustion,but havenotoperated,shouldbereplaced iftheycannotbecompletelycleaned bywipingthesprinklerwithaclothor bybrushingitwithasoftbristlebrush.Caremustbeexercisedtoavoiddam-agetothesprinklers-before,during,andafterinstallation.Sprinklersdam-agedbydropping,striking,wrench twist/slippage,orthelike,mustbere-placed.Also,replaceanysprinklerthat hasacrackedbulborthathaslost liquidfromitsbulb.(Ref.Installation Section).Theownerisresponsibleforthein-spection,testing,andmaintenanceof theirfireprotectionsystemandde-vicesincompliancewiththisdocu-ment,aswellaswiththeapplicable standardsoftheNationalFireProtec-tionAssociation(e.g.,NFPA25),in additiontothestandardsofanyother authoritieshavingjurisdiction.Thein-stallingcontractororsprinklermanu-facturershouldbecontactedrelative toanyquestions.NOTE Theownermustassurethatthesprin-klersarenotusedforhangingofany objectsandthatthesprinklersareonly cleanedbymeansofgentlydusting withafeatherduster;otherwise,non-operationintheeventofafireorinad-vertentoperationmayresult.Automaticsprinklersystemsshouldbe inspected,tested,andmaintainedbya qualifiedInspectionServiceinaccord-ancewithlocalrequirementsand/or nationalcodes.Limited Warranty ProductsmanufacturedbyTycoFire&BuildingProducts(TFBP)arewar-rantedsolelytotheoriginalBuyerfor ten(10)yearsagainstdefectsinmate-rialandworkmanshipwhenpaidfor andproperlyinstalledandmaintained undernormaluseandservice.This warrantywillexpireten(10)years fromdateofshipmentbyTFBP.No warrantyisgivenforproductsorcom-ponentsmanufacturedbycompanies notaffiliatedbyownershipwithTFBP orforproductsandcomponentswhich havebeensubjecttomisuse,improper installation ,corrosion,orwhichhave notbeeninstalled,maintained,modi-fiedorrepairedinaccordancewithap-plicableStandardsoftheNationalFire ProtectionAssociation,and/orthe standardsofanyotherAuthorities HavingJurisdiction.Materialsfound byTFBPtobedefectiveshallbeeither repairedorreplaced,atTFBP’ssole option.TFBPneitherassumes,nor authorizesanypersontoassumeforit,anyotherobligationinconnectionwith thesaleofproductsorpartsofprod-ucts.TFBPshallnotberesponsiblefor sprinklersystemdesignerrorsorinac-curateorincompleteinformationsup-pliedbyBuyerorBuyer’srepre-sentatives.InnoeventshallTFBPbeliable,in contract,tort,strictliabilityorunder anyotherlegaltheory,forincidental,indirect,specialorconsequentialdam-ages,includingbutnotlimitedtolabor charges,regardlessofwhetherTFBP wasinformedaboutthepossibilityof suchdamages,andinnoeventshall TFBP’sliabilityexceedanamount equaltothesalesprice.Theforegoingwarrantyismadeinlieu ofanyandallotherwarranties,ex -pressorimplied,includingwarranties ofmerchantabilityandfitnessforapar -ticularpurpose.Thislimitedwarrantysetsforththeex-clusiveremedyforclaimsbasedon failureofordefectinproducts,materi-alsorcomponents,whethertheclaim ismadeincontract,tort,strictliability oranyotherlegaltheory.Thiswarrantywillapplytothefullex-tentpermittedbylaw.Theinvalidity,in wholeorpart,ofanyportionofthis warrantywillnotaffecttheremainder.Ordering Procedure Whenplacinganorder,indicatethe fullproductname.Contactyourlocal distributorforavailability..SprinklerAssembly:SeriesLFII(TY2334),K=4.4,Residen-tialHorizontalSidewallSprinklerwith (specify)temperatureratingand (specify)finish,P/N(specify).155°F/68°Cor ChromePlated.........P/N51-215-9-155 155°F/68°C WhitePolyester.........P/N51-215-4-155 155°F/68°C NaturalBrass...........P/N51-215-1-155 175°F/79°Cor ChromePlated.........P/N51-215-9-175 175°F/79°C WhitePolyester.........P/N51-215-4-175 175°F/79°C NaturalBrass...........P/N51-215-1-175 RecessedEscutcheon:Specify:Style20RecessedEscutch-eonwith(specify*)finish,P/N(spec-ify*).*RefertoTechnicalDataSheetTFP770.SprinklerWrench:Specify:W-Type6SprinklerWrench,P/N56-000-6-387.Specify:W-Type7SprinklerWrench,P/N56-850-4-001.Page6of6 TFP412 ©2007TYCOFIRE&BUILDINGPRODUCTS,451NorthCannonAvenue,Lansdale,Pennsylvania19446 Wrot Copper and Bronze Solder-Joint Pressure Fittings Dimensions of Soldered-Joint Ends (in inches)Male EndFemale EndInside Standard Diameter WaterOusideInsideWallof TubeDiameterLengthDiameterDepthThicknessFitting SizeAKFGTO Min.Max.Min.Min,Max.Min.Avg.Min.Engineering Data E lkhart Products Corporation 39 Working Pressures and Solder The table of maximum working pressures below must be understood to reflect what is generally considered as good engineering practice under reasonably constant and favorable conditions; i.e.,pressures which are fairly steady, absence of particularly corrosive media, etc. Unusual conditions require increased safety factors and therefore,lower working pressures should be used.Rated Internal Working Pressures of Piping System Made of Copper Water Tube and Soldered Fittings ServicePOUNDS PER SQUARE INCH Solder UsedTemp.Water (a)in joints°FCopper Water Tube-Nominal Sizes 1 ⁄8 " to 1"1 1 ⁄4 " to 2"2 1 ⁄2 " to 4"5" to 8"Incl.Incl.Incl.Incl.* 50-50 100200175150135 Tin-Lead (b)15015012510090 200100907570 25085755045 95-5 100500400300270 Tin-Antimony 150400350275250 (c) (d)200300250200180 250200175150135 Brazing AlloysTemperature and pressure ratings consistent with the Melting at ormaterials and procedures employed.above 1000°F.*The data given for 50% tin-50% lead applies also for the 40% tin-60% lead alloy.The values in this table are based on data in the National Bureau of Standards Publications,“Building Materials and Structures Reports BMS 58 and BMS 83.”(a) Including other noncorrosive liquids and gases (b)ASTM B32, Alloy Grade Sn 50 (c)ASTM B32, Alloy Grade Sb 5 (d)The Safe Drinking Water Act Amendment of 1986 prohibits the use in potable water. Systems of any solder having a lead content in excess of 2%.NOTE: The table at left is from data published by the Copper and Brass Research Association.Estimated Quantity of 50-50 Solder Required to Make 100 Joints Size in Inches 3/81/2 3/4 11 1/41 1/2 2 2 1/2 3 3 1/2 4 5 6 8 Quantity in Pounds .5.751.01.41.71.92.43.23.94.55.581532 1. The quantity of hard solder used is dependent in the skill of the operator, but for estimating purposes, 75% of the above fig ures may be used.2. Two ounces of Solder Flux will be required for each pound of solder.0.2520.2560.25 0.3770.3810.31 0.5020.5060.38 0.6270.6310.50 0.7520.7560.62 0.8770.8810.75 1.1281.1320.91 1.3781.3820.97 1.6281.6331.09 2.1282.1331.34 2.6282.6331.47 3.1283.1331.66 3.6283.6331.91 4.1284.1332.16 5.1285.1332.66 6.1286.1333.09 8.1288.1333.97 1/80.2480.2510.31 1/40.3730.3760.38 3/80.4970.5010.44 1/20.6220.6260.56 5/80.7470.7510.69 3/40.8720.8760.81 11.1221.1270.97 1 1/41.3721.3771.03 1 1/21.6211.6271.16 22.1212.1271.41 2 1/22.6212.6271.53 33.1213.1271.72 3 1/23.6213.6271.97 44.1214.1272.22 55.1215.1272.72 66.1216.1273.22 88.1198.1274.09 K T O A T G O F T T O A T G O F T T Male End Female End .0190.18 .0230.30 .0260.39 .0290.52 .0310.63 .0330.74 .0400.98 .0441.23 .0511.47 .0591.94 .0672.42 .0752.89 .0863.37 .0963.84 .1114.70 .1245.72 .1737.55 Engineering Data Fitting Material:Copper Alloy #122, Phosphorus Deoxidized-High Residual Phosphorus (DHP).Composition: 99% Copper; .015-.040% Phosphorus.Weld Material:Silicon Bronze. Meets speci fi cation American Welding Society (AWS) A5.7-91R and American Metals Society.Weld Speci fi cations:Tensile Strength-Up to 58,000 PSI Yield Strength-Up to 25,000 PSI Elongation in 2"-53% to 55%Hardness-80 to 100 Brinell (500kg. Load)Temperature: Melt 1832 °F, Flow 1931 °F.Method of Joining:Electric Weld.Dimensions & Speci fi cations:EPC Welded fi ttings are produced in accordance with speci fi cations shown in Manufactures Standardization Society (MSS) SP-109 for wrought copper, and copper alloy solder-joint pressure fi ttings.Testing:Each fi tting is individually tested with air under water.The burst pressure of EPC welded fi ttings exceeds the recommended working pressure of comparable diameter, annealed, straight, seamless ASTM B88-96-Atype “L ” copper water tube by a safety factor of 4:1 or more.Wrot Copper Fittings Large Diameter Welded Design 40 Elkhart Products Corporation †Slight variations from these weights must be expected in practice.Extracted from American National Standard Wrought Copper and Bronze Solder-Joint Drainage Fittings (ANSI B16.29) with permission of the publisher. The American Society of Mechanical Engineers, 345 East 47th St., New York, N.Y.Copper Water Tube-Standard Dimensions and Weights OutsideInside Diameter, InchesWall Thickness, Inches †Pounds per Linear Foot NominalDia., In.TubeTypesTypeTypeTypeType TypeTypeTypeType TypeTypeTypeType SizeK-L-M-KLMDWV KLMDWV KLMDWV InchesDWV 1/4.375.305.315--.035.030.025-.145.126.106-3/8.500.402.430--.049.035.025-.269.198.145-1/2.625.527.545--.049.040.028-.344.285.204-5/8.750.652.666--.049.042.030-.418.362.263-3/4.875.745.785--.065.045.032-.641.455.328-11.125.9951.025--.065.050.035-.839.655.465-1 1/41.3751.2451.2651.2911.295.065.055.042.0401.04.884.682.650 1 1/21.6251.4811.5051.5271.541.072.060.049.0421.361.14.940.809 22.1251.9591.9852.0092.041.083.070.058.0422.061.751.461.07 2 1/22.6252.4352.4652.495-.095.080.065-2.932.482.03-33.1252.9072.9452.9813.035.109.090.072.0454.003.332.681.69 3 1/23.6253.3853.4253.459-.120.100.083-5.124.293.58-44.1253.8573.9053.9354.009.134.110.095.0586.515.384.662.87 55.1254.8054.8754.9074.981.160.125.109.0729.677.616.664.43 66.1255.7415.8455.8815.959.192.140.122.08313.910.28.926.10 88.1257.5837.7257.785-.271.200.170-25.919.316.5-Wrot Copper Solder-Joint Drainage Fittings Dimensions of Soldered-Joint Ends (in inches) See Diagram Page 39 Male EndFemale EndInside MetalDiameter SizeOutside DiameterLengthInside DiameterDepthThicknessof Fitting AKFGTO Min.Max.Min.Min.Max.Min.Min.Min.1 1/41.3721.3770.561.3781.3820.500.0401.29 1 1/21.6211.6270.621.6281.6330.560.0421.53 22.1212.1270.692.1282.1330.620.0422.01 33.1213.1270.813.1283.1330.751.0452.98 44.1214.1271.064.1284.1331.000.0583.93 36 ➀ADAPTERS ELBOWS COUPLINGS FIGURE 5. Selected Pressure Fittings GENERAL NOTES: (a) Fittings are designated by size in the order: 1x2x3 (b) Fitting designs and drawings are for illustration on ly. Page 6 Note: Screws must be installed with appropriate nut driver to comply with warranty Item#Model Screw Description BoxQty Weight (per100)CaseQty 50DSTR1001/4-20x1 1006.251000 51DST1001/4-14x1 1005.251000 52DST1501/4-14x11/2 1005.501000 53DST2001/4-14x2 1006.001000 54DST2501/4-14x21/2 1006.751000 55DST3001/4-14x3 1007.251000 56TEK50012-24x11/2 1005.501000 Use#14NutDriver(Item#100)STEEL•1/4"Rod(VerticalMount)Item#Model Screw Description Minimum Thickness Maximum Thickness ActualPulloutBoxQty Weight (per100)CaseQty 601DST2.01/4-14x2 .188"-3/16"1/4"506.75500 1113DST2.51/4-14x21/2 .188"-3/16"1/4"507.25500 422DSTR1.01/4-20x1 .036"-20ga1/4"1510#/20ga50500.007 28DSTR5.165/16-18x11/4 .036"-20ga1/4"2220#/20ga508.00500 443DST5.165/16-18x11/4 .188"-3/16"1/4"1500+#/3/16"506.75500 05TEK5.012-24x11/2 .25"-1/4"1/2"3125#/1/4"506.00500 STEEL•1/2"Rod(VerticalMount)Use#14SWNutDriver(Item#101)ApprovalsItem#Model Screw Description FMTest Load,lb.ULTest Loadlb.UL/FM PipeSize Minimum Thickness Maximum Thickness ActualPulloutBo x UL •FM •NFPA 29DSTR11/2"12-24x11/2 1475#1500#3/4-41/4"1/2"1510#/1/4"1 UL •FM •NFPA 30DSTR1"1/4-20x1 1475#1500#3/4-4.036"-20ga1/4"1510#/20ga 1 UL •NFPA 31DSTR516 5/16-18x11/4 1500#4.036"-20ga1/4"2200#/20ga 1 NFPA 32DST10 1/4-14x1 .036"-20ga1/4"446#/20ga 1 NFPA 33DST15 1/4-14x11/2 1/4"970#/16ga 1 NFPA 34DST20 1/4-14x2 1/4"1 NFPA 35DST25 1/4-14x21/2 1/4"1 NFPA 36DST30 1/4-14x3 1/4"1 UL •NFPA 37DST516 5/16-18x11/4 1500#4.188"-3/16"1/4"1500#/3/16"1 FM •NFPA 38TEK50 12-24x11/2 1475#1/4"1/2"3125#/1/4"1 STEEL•3/8"Rod(VerticalMount)Use#14NutDriver(Item#100)Note:Screwdiameter/design/performancefortheDST10(1"length)throughtheDST30(3"length)areconstant.Onlythe lengthsvary.STEEL — Sammys For fastening/anchoring in high vibratory environme nts, consult local code authorities for accepted an choring devices #14 (Item #100-black)Sammys 1/4”, 3/8” rod UL Listings and CAD Drawings are available at www.S ammySuperScrew.com #14SW (Item #101-red)Sidewinders &Sammys 1/2” rod Self-Drilling • Self-tapping Page 7 Note: Screws must be installed with appropriate nut driver to comply with warranty Item#Model Screw Description Minimum Thickness Maximum Thickness Actual Shear/Pullout BoxQty Weight (per100)CaseQty 2003SWD1001/4-14x1 .066"-16ga1/4"1477#/16ga1006.001000 407SWD2001/4-14x2 .066"-16ga1/4"1477#/16ga1006.501000 206SWDR1001/4-20 .036"-20ga1/4"1900#/20ga1006.001000 STEEL•1/4"Rod(HorizontalMount)Use#14SWNutDriver(Item#101)Approval s Item#Model Screw Description ULTest Loadlb.UL/FM PipeSize Minimum Thickness Maximum Thickness Actual Shear/Pullout BoxQty Weig h (per10 0 NFPA 39SWD101/4-14x1 .066"-16ga1/4"1477#/16ga1006.00 NFPA 40SWD151/4-14x11/2 1007.50 NFPA 41SWD201/4-14x2 1006.50 NFPA 42SWD5165/16-18x11/4 1007.00 UL •NFPA 46SWDR11/2"1/4-20x11/2 1500#4.25"-1/4"1/2"2375#/.25"-1/4"1007.25 UL •NFPA 43SWDR1"1/4-20x1 1500#4.036"-20ga1/4"1900#/20ga1007.00 UL •NFPA 44SWDR5165/16-18x11/4 1500#4.036"-20ga1/4"2480#/20ga1008.25 NFPA 45SWT1512-24x11/2 .25"-1/4"1/2"1006.25 Use#14SWNutDriver(Item#101)STEEL•3/8"Rod(HorizontalMount)Note:Screwdiameter/design/performanceforSWD10(1"len gth)throughSWD20(2"length)areconstant.Onlythelengthsvar ry.STEEL —Sidewinders steel screw shown with retainer nut SWDR screws include retainer nut #14SW (Item #101-red)Sidewinders &Sammys 1/2” rod For fastening/anchoring in high vibratory environme nts, consult local code authorities for accepted an choring devices P ERFORMANCE D ATA FOR S TEEL ModelDia.Pt..114.092.365.132 DST10 1/4#31265#2750#SWD10 1/4#31120#1420#AluminumCurtainWallExtrusion (averagelbs.ultimate)FastenerThickness UltimatePulloutValues ModelDia.Pt.20181614123/161/4 DST 1/4#3446#613#970#1145#1544#3190#DST516 5/16#3457#568#1209#1712#2422#3716#TEK50 #12#5487#699#913#1527#3270#3593#DSTR11/2"#12#5 3270#3593#DSTR1"1/4#31510#DSTR516 5/16#32200#UltimatePulloutValues-Sammys (averagelbs.ultimate)FastenerSteelGauge ModelDia.Pt.20181614123/161/4 SWD 1/4#31477#SWDR11/2"#12#52375#SWDR1"1/4#31900#1900#SWDR516 5/16#32480#2480#UltimateShear/PulloutValues-Sidewinders (averagelbs.ultimate)FastenerSteelGauge GaugeNo.1/43/161214161820222426 DecimalEquivalent .25.188.105".075".060".048".036".030".024".018"SHEETSTEELGAUGES Self-Drilling • Self-tapping 302 RINGHANGER SIZE-MATERIAL-StainlessSteel-(Type304)CONFORMSWITH:MAXIMUMTEMPERATURE FUNCTION-INSTALLATION FEATURES ORDERING-1/2thru8inchpipe.FederalSpecificationWW-H-171(Type10,ManufacturersStandardizationSocietyANSI/MSS-SP-58(Type10).-650F.Pipehangercomponentforuseonsteelor copperpiping.ForusewithCPVC-consultfactory.-P -*Stainlesssteelswivelnut.*Customfitswivelnutforbetterretentioninringbody.Part#,pipesize.Note:OnCopper-Insulatepipe.0 erNFPA-13,13Rand13D.*Sizedandlistedexclusivelyforusewith#310SurgeRestrainer.08/03 PIPE 1/2 3/4 1 11/4 11/2 2 21/2 3 31/2 4 5 6 8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 1/2 1/2 1/2 400 400 400 400 400 400 600 600 600 1000 1250 1250 1250 10 10 10 10 10 10 10 10 10 10 12 12 12 *OrderPart#300m LOADLBS.METRIC*ROD MAXREC.IMPERIAL PIPE ROD 20 25 32 40 50 65 80 100 125 150 200 Note:1/2"RingHangernot<FM>approved 650 ALLTHREADEDROD10'-0'LENGTHS SIZE MATERIAL FINISH ORDERING -1/4thru11/2inchrodin10'-0"lengths.-CarbonSteel.-Plain,Electro-Galvanizedand StainlessSteel.-Part#,roddiameterandfinish.1/4 3/8 1/2 5/8 3/4 7/8 1 11/4 11/2 240 610 1130 1810 2710 3770 4960 8000 11630 215 540 1010 1610 2420 3360 4420 7140 10370 NOTE;maximumTemperature:750°F ROD SIZE MAX.REC.LOADLBS.FORSERVICETEMP.650°F750°F 2/00