HomeMy WebLinkAboutB07-0198 inspectionsSecItem IdDescriptionApprReqItemsActionInheritable
*10 BLDG-FOOTINGYesO2APNo
*20 BLDG-Foundation/Steel YesO1APNo
*21 PLAN-ILC Foundation Plan YesR1APNo
*30 BLDG-Framing YesO9APNo
*22 PLAN-ILC FRAMINGYesR1APNo
*50 BLDG-Insulation YesO3APNo
*60 BLDG-Sheetrock Nail YesO2APNo
*539 PW-FINAL C/O YesO2APNo
*537 PLAN-FINAL C/O YesO3APNo
*540 BLDG-Final C/O YesO2APNo
*560 ELEV-Final YesR1APNo
Total Rows: 11
Page 1
Inspection Items for B07-019808:34 04/05/2012
ActionComments ByDateUnique_
Key
AP MH01/16/2009A000121
969
Total Rows: 1
Page 1
B07-0198: Entries for Item:560 - ELEV-Final 08:36 04/05/2012
ActionComments ByDateUnique_
Key
DNM,P PERMITS REQUIRE FINAL
INSPECTIONS
CALL FROM REINSPECTION,
JRM10/02/2008A000118
258
AP JRM10/08/2008A000118
471
Total Rows: 2
Page 1
B07-0198: Entries for Item:540 - BLDG-Final C/O 08:36 04/05/2012
ActionComments ByDateUnique_
Key
DNrear retaining wall exceeds 6 feet in height, no
shingles on roof, vent/conduit/meter painting
not completed
bgibson08/22/2008A000116
892
DNroof shingles not completedbgibson09/16/2008A000117
655
AP bgibson10/02/2008A000118
296
Total Rows: 3
Page 1
B07-0198: Entries for Item:537 - PLAN-FINAL C/O 08:36 04/05/2012
ActionComments ByDateUnique_
Key
DNRetaining wall at the NE corner exceeds 6
feet.
cdelles08/21/2008A000116
841
APOwner installed a planter in front of the wallcdelles09/19/2008A000117
799
Total Rows: 2
Page 1
B07-0198: Entries for Item:539 - PW-FINAL C/O 08:36 04/05/2012
ActionComments ByDateUnique_
Key
APFIREPLACE CHASE GYP GREATROOM
AND LOFT
GCD01/29/2008A000110
844
APDrywall screws approved, no corrections.JGG04/02/2008A000112
257
Total Rows: 2
Page 1
B07-0198: Entries for Item:60 - BLDG-Sheetrock Nail 08:36 04/05/2012
ActionComments ByDateUnique_
Key
CRSPRAY-ON INSULATION IN ATTIC DOES
NOT MEET IGNITION BARRIER
REQUIREMENT PER ES-4.2.
INSULATION CERTIFICATE RECEIVED
FOR FILE.
SHAHN03/18/2008A000111
917
CRTHE ATTIC HAS SPRAY FOAM
INSULATION. AN IGNITION BARRIER IS
REQUIRED PER THE ES REPORT AND
ALSO IRC 314. THE CEILING INSULATION
IS NOT ON APPROVED PLANS AND MAY
BE AN ISSUE BY CAUSING A COLD ATTIC.
shahn03/19/2008A000111
941
AP jrm10/07/2008A000118
416
Total Rows: 3
Page 1
B07-0198: Entries for Item:50 - BLDG-Insulation 08:35 04/05/2012
ActionComments ByDateUnique_
Key
AP bgibson02/22/2008A000111
336
Total Rows: 1
Page 1
B07-0198: Entries for Item:22 - PLAN-ILC FRAMING08:35 04/05/2012
ActionComments ByDateUnique_
Key
NOILC REQUIRED LEFT MESSAGE AT GC #
376-2020 8:35 A.M.
JRM02/08/2008A000111
055
NONOTIFIED MIKE YOUNG THAT FRAMING
CANNOT BE DONE UNTIL ILC IS
APPROVED.
FIREPLACE CORRECTIONS NOT
APPROVED.
shahn02/21/2008A000111
313
DNDENIED ... A FIRE ALARM AND SPRINKLER
PERMIT AND INSPECTIONS ARE
REQUIRED.
JRM02/26/2008A000111
393
DNNO SPRINKLER ALARM HAS BEEN
APPROVED OR APPLIED FOR ON THIS
HOUSE.. FRAMING DENIED UNTIL ALL
INSPECTIONS ROUGHS ARE APPROVED
JRM03/07/2008A000111
696
NONO SPRINKLER REQUIRED OK TO
INSPECT FRAMING
JRM03/11/2008A000111
755
NOSTILL NEED TO REINSPECT FIREPLACE
CORRECTIONS.
NOTIFIED MIKE YOUNG THAT MECH
DUCTWORK PERMIT HAS NOT BEEN
ISSUED.
shahn03/11/2008A000111
758
CRNEED LETTER FROM STRUCTURAL
ENGINEER :
1) AREAS COVERED WITH FOAM
INSULATION HAVE BEEN APPROVED BY
ENGINEER.
2) MISSING THRU BOLTS IN MASTER
BEDROOM.
3) MISSING JOIST BLOCKING IN GUEST
MASTER.
4) MISSING HSS3X3X3-3/16 IN GUEST
MASTER BATH.
PROVIDE INFORMATION ON FOAM
INSULATION TO ADDRESS IF THERMAL
BARRIER IS REQUIRED IN ATTIC SPACE.
NAIL PROTECTION REQUIRED IN
SEVERAL PLACES FOR FLEX DUCT, PVC
PIPING AND ELECTRICAL.
INSULATE HOT AND RECIRC WATER PER
IECC.
REMOVE SCREWS FROM CLOTHES
DRYER DUCT PER IMC.
SHAHN03/12/2008A000111
794
CRINSULATION HAD ALREADY STARTED,
COVERING WORK.
ITEMS FROM PREVIOUS FRAMING
INSPECTION NOT
CORRECTED/INSPECTED, SUCH AS
SCREWS REMAIN IN DRYER DUCTS,
MISSING NAIL PROTECTION FOR
ELECTRICAL CABLE, HOT/RECIRC NOT
INSULATED. STOPPED INSPECTION.
INFORMED TODD TO REMOVE AS
REQUIRED TO INSPECT DRYER DUCT
AND WATER INSULATION.
SHAHN03/14/2008A000111
859
APFRAMING APPROVED.
RECEIVED LETTER FROM STRUCTURAL
ENG DATED 3/17/08.
SHAHN03/18/2008A000111
916
Total Rows: 9
Page 1
B07-0198: Entries for Item:30 - BLDG-Framing 08:35 04/05/2012
ActionComments ByDateUnique_
Key
AP bgibson02/22/2008A000111
335
Total Rows: 1
Page 1
B07-0198: Entries for Item:21 - PLAN-ILC Foundation Plan 08:35 04/05/2012
ActionComments ByDateUnique_
Key
APsee footer notesjrm10/07/2008A000118
417
Total Rows: 1
Page 1
B07-0198: Entries for Item:20 - BLDG-Foundation/Steel 08:35 04/05/2012
ActionComments ByDateUnique_
Key
CRSOILS REPORT RECEIVED.
NORTH COUNTERFORT IS NOT PER PLAN
REQS ADDITIONAL MAT AND 7 #6, BULK
HEAD OFF AND REINSPECT. REST OF
FOOTING IS APPRVED UFER GROUND IN
SE CORNER
GCD08/30/2007A000104
323
APfoundation walls approved. The revised
entrance stairway was brought into comdev
and approved.
shahn09/13/2007A000104
864
Total Rows: 2
Page 1
B07-0198: Entries for Item:10 - BLDG-FOOTING08:34 04/05/2012