Loading...
HomeMy WebLinkAboutA12-0024 CUT SHEETS ______________________________________________________________________________________ Security, Fire, CCTV, Access Control, Custom Audio/Video, and Automation ______________________________________________________________________________________ Post Office Box 4910  Edwards, Colorado 81632  Phone (970) 926-8788  Fax (970) 926-8790 www.superioralarmco.com  admin@superioralarmco.com May 29, 2012 Department of Community Development 75 South Frontage Road Vail, Colorado 81657 RE: 352 Beaver Dam Circle, Unit-A, Contact Information Premise Phone #970-476-5534 Response Party 1: Amy Byers – Holm – Cell Phone #970-376-2489 Response Party 2: Claes Holm – Cell Phone #970-390-1315 Daniel Dimitrov NCET II Fire Alarms Cert. #119879 ______________________________________________________________________________________ Security, Fire, CCTV, Access Control, Custom Audio/Video, and Automation ______________________________________________________________________________________ Post Office Box 4910  Edwards, Colorado 81632  Phone (970) 926-8788  Fax (970) 926-8790 www.superioralarmco.com  admin@superioralarmco.com May 29, 2012 Department of Community Development 75 South Frontage Road Vail, Colorado 81657 RE: 352 Beaver Dam Circle, Unit-A Device List. 1. 1x Ademco Vista 128-SIA – addressable fire alarm control panel. 2. 2x Ademco 6160 – alpha keypad. 3. 1x Ademco 4204 – relay module. 4. 17x Ademco 4193SN – Point ID serialized interface module. 5. 3x Sustem Sensor BK-CI1224T – hardwired carbon monoxide detector. 6. 11x ESL449CST – 4 wire photo-electric smoke detector with built in mini sounder. 7. 1x ESL 405-05 – polarity reversal module. 8. 1x ESL – 204-12/24V – power supervision module. 9. 6x System Sensor BK5603 –1350 F fixed temp heat detector. 10. 1x System Sensor MHW –mini horn in white. 11. 1x Knox 3724 – recessed key vault. 12. Belden B5322UL – 18AWG, 4 conductor fire wire. Daniel Dimitrov NCET II Fire Alarms Cert. #119879 ______________________________________________________________________________________ Security, Fire, CCTV, Access Control, Custom Audio/Video, and Automation ______________________________________________________________________________________ Post Office Box 4910  Edwards, Colorado 81632  Phone (970) 926-8788  Fax (970) 926-8790 www.superioralarmco.com  admin@superioralarmco.com May 29, 2012 Department of Community Development 75 South Frontage Road Vail, Colorado 81657 RE: 352 Beaver Dam Circle, Unit-A, Monitoring Information Monitoring Method – Digital Alarm Communicator. Monitoring Agency – Central Security Station, Greely CO. Daniel Dimitrov NCET II Fire Alarms Cert. #119879 ______________________________________________________________________________________ Security, Fire, CCTV, Access Control, Custom Audio/Video, and Automation ______________________________________________________________________________________ Post Office Box 4910  Edwards, Colorado 81632  Phone (970) 926-8788  Fax (970) 926-8790 www.superioralarmco.com  admin@superioralarmco.com May 29, 2012 Department of Community Development 75 South Frontage Road Vail, Colorado 81657 RE: 352 Beaver Dam Circle Scope of Work Letter Scope of work at 325 Beaver Dam Circle, Unit-A consists of the following: 1. Replace the existing FACP with addressable Ademco Vista 128-SIA; 2. Replace existing 2 annunciators with Ademco compatible 6160; 3. Add a hard wired horn in the garage; 4. Replace the existing heat detectors with 1350 F fixed temp ones; 5. Relocate existing smoke detector in the living room closer to the peak of the ceiling – east; 6. Add a hard wired smoke detector to the west peak of the ceiling; 7. Add a hardwired smoke detector in the mud room; 8. Add a hardwired heat detector in the laundry room; 9. Add two hardwired heat detectors in the crawl space; 10. Add two smoke detectors in the bedrooms on the lower level; 11. Add two smoke detectors in the new family room and main level bedroom; 12. Add a smoke detector in the new upper level bedroom; 13. Add three hardwired carbon monoxide detectors adjacent to the sleeping areas on the lower, main and upper levels; 14. Install a Knox Box to the right of the garage over-head door. Daniel Dimitrov NCET II Fire Alarms Cert. #119879 ______________________________________________________________________________________ Security, Fire, CCTV, Access Control, Custom Audio/Video, and Automation ______________________________________________________________________________________ Post Office Box 4910  Edwards, Colorado 81632  Phone (970) 926-8788  Fax (970) 926-8790 www.superioralarmco.com  admin@superioralarmco.com May 29, 2012 Department of Community Development 75 South Frontage Road Vail, Colorado 81657 RE: 352 Beaver Dam Circle, Fire Zones Information 1. Lower Level West Entrance 2. Lower Level Crawl East 3. Lower Level Crawl West 4. Lower Level Laundry Room 5. Lower Level West Mechanical Room 6. Lower Level Hallway 7. Lower Level East Bedroom 8. Lower Level West Bedroom 9. Lower Level Storage Under Stairs 10. Lower Level Garage 11. Main Level Living Room East 12. Main Level Living room West 13. Main Level Kitchen 14. Main Level South Family Room 15. Main Level South Bedroom 16. Upper Level West Loft 17. Upper Level South Bedroom 18. Lower Level Hallway CO Detection 19. Main Level O/S Bedroom CO detection 20. Upper Level Sleeping Area CO Detecetion Daniel Dimitrov NCET II Fire Alarms Cert. #119879 6160 ALPHA DISPLAY KEYPAD CO06010 L/6160/D September 2006 © 2006 Honeywell International Inc. Honeywell Security & Custom Electronics Honeywell International Inc. PO Box 9035 Syosset, NY 11791 www.honeywell.com ORDERING 6160 Alpha Display Keypad The 6160 Deluxe Keypad is easy to install and simple to use. The attractive white console blends with any décor and features a contoured, removable door that conceals illuminated soft-touch keys. The 6160 also features a new larger and brighter 32-character display with easy-to-read plain-English status messages. The oversized function keys are easily accessed even when the keypad door is closed, and can be programmed for fire, burglary, personal emergencies and other operations. Colored self-adhesive labels are included. • Large, easy-to-use keypad • Keys continuously backlit for greater visibility • Speaker with audible beeps to indicate: - System status - Entry/exit delay - Other alarm situations • Zones and system events displayed in plain English • No confusing blinking lights • Four programmable function keys • System functions clearly labeled • Functions performed by just entering security code plus command • White with removable door blends with any décor FEATURES Physical • 5-5/16"H x 7-3/8"W x 1-3/16"D (135mm x 190mm x 30mm) Current • Standby-40mA • Activated Transmission-160mA Wiring • - (Black):Ground • + (Red):+12 VDC (Aux. Power) • D1 (Green):“Data in” to control panel • D0 (Yellow):“Data out” from control panel Compatibility • Fully compatible with all VISTA controls. SPECIFICATIONS WITH DOOR ATTACHED WITHOUT DOOR K3590-ADV2 4/04 Rev. A ADEMCO 6150 & 6160 REMOTE KEYPADS INSTALLATION AND SETUP GUIDE Keypad Features ADEMCO 6150 Fixed-Word ADEMCO 6160 2-Line Alpha Backlit Display YES (see note) YES (see note) Dedicated Function Keys YES YES Built-in Sounder Piezo Speaker Note: Permanent display backlighting is an option on some controls (see the control's instructions for details). GENERAL INFORMATIONWIRING AND INSTALLATION The ADEMCO 6150 and ADEMCO 6160 are addressable Remote Keypads designed for use with ADEMCO control panels. Addresses are set via the keypad keys. The keys on the keypads are continuously backlit for convenience. KEYPAD DISPLAYS AND LEDS The keypads have the following display features: Model Fixed Word Display 2-line Alpha Display 2-digit Zone Identifier Custom Zone Descriptors 6150 X X 6160 X X The following table shows the LEDs and their functions: LED Function Red Lights when the system is armed in any mode Green Lights when the system is "ready" to be armed. SPECIAL FUNCTION KEYS The keypads also feature function keys. These keys may be programmed for panic alarms or other special functions such as macros. See the control's instructions for details. The keypads can be surface mounted directly to a drywall, or to a single- or double-gang electrical box. 1.Remove the case back by pushing down two "snaps." See diagram below. 2.Route wiring from the control panel through the opening in the case back. 3.Mount the case back to a wall or electrical box. 4.Wire directly from the keypad’s terminal block to the terminal block on the control board as follows: Wiring Table (All Keypads) Keypad Control Panel Wire Color GData InGreen –– Aux Pwr (GND)Black ++ Aux. PwrRed YData OutYellow See the control panel’s Installation and Setup Guide for more complete details. 5.Reattach the keypad to its case back. RETAINING SNAPS NOTE: TO REMOVE CASE BACK PUSH IN THE TWO MOUNTING SNAPS LOCATED ALONG THE BOTTOM OF THE KEYPAD AND LIFT UP. 61 5 0 - 0 0 6 - V 0 ARMED READYFunction keys must be held down for at least 2 seconds to activate an alarm, key pairs activate immediately. Function Keys A or [1] and [✱] B or [✱] and [#] C or [3] and [#] D ÊK3590-ADV2KŠ K3590-ADV2 4/04 Rev. A SETTING THE KEYPAD ADDRESSFUNCTION KEY LABELS The keypad can either be set for an address of 00-30, or to the non-addressable mode (31). The keypad's default address is 31. To change the keypad's address, do the following: 1. Enter address mode: Power up the keypad. Within 60 seconds of power-up, press and hold down the [1] and [3] keys at the same time for 3 seconds. (If unable to enter address mode, power up and try again.) The current keypad address will be displayed, and the cursor will be under the "tens" digit. If 10 seconds have passed with no key entry, the keypad automatically exits address mode. You must power down, power up and start address mode again. NOTE: The keypad will not enter address mode if the panel to which it is connected is in programming mode. 2. Set the current address to "00": Press [0] to clear the current "tens" digit. The cursor will move to the "ones" digit position. Press [0] to clear the current "ones" digit. The cursor will move back to the "tens" digit position. 3. Enter the keypad's address: Enter the proper "tens" digit of the keypad's address. The cursor will move to the "ones" digit position. Enter the proper "ones" digit of the keypad's address. Note that address "31" sets the keypad to non-addressable mode. 4. Exit address mode: Press [✱] to save the displayed address and exit address mode. VIEWING THE KEYPAD ADDRESS Press and hold down the [1] and [3] keys at the same time for about 3 seconds. The current address is displayed. No key entry is allowed. Press any key to exit or wait 10 seconds to exit viewing mode. A set of adhesive-backed labels with some typical function symbols (i.e., fire, police, personal emergency, etc.) is provided. These labels can be placed on or next to the keys to identify each key's function for the end user (as determined by the control panel's capability and programming; see the control's instructions). SPECIFICATIONS Physical: 6150: 4-7/8"H x 6-1/4"W x 1"D 6160: 5-5/16"H x 7-3/8"W x 1-3/16"D Displays: 6150: Fixed-Word LCD (backlit). 6160: 2 x 16 alpha-numeric supertwist LCD, backlit. Sounder: 6150: Piezo-electric (fire alarm is loud, pulsing single tone; (all Keypads) burglary alarm is loud, continuous, dual tone). 6160: Speaker. Voltage: 12VDC Current: 6150: 70mA (ARMED LED lit, LCD backlight and sounder on), reduces to 40mA when panel is operating in standby mode (backlight off). 6160: 150mA (ARMED LED lit, LCD backlight and sounder on), reduces to 40mA when panel is operating in standby mode (backlight off). REFER TO INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM. 165 Eileen Way, Syosset, New York 11791 Copyright© 2004 Honeywell International Inc. www.honeywell.com/security Control Unit Accessories, System Backup dialer modules, Model(s) 5140DLM Eight-zone remote point Class A interface modules, Model(s) 4208SNF Eight-zone remote point modules, Model(s) 4208SN, 4208U Enclosures, Model(s) 5800BOX End-of-line resistors, Model(s) 4100EOLR, EOL100, EOL20, EOL22, EOL82, EOLR470K Fire system annunciator keyswitch modules, Model(s) FSAKSM (d) Fire system annunciator modules, Model(s) FSA-24F, FSA-8F Internet and Digital Cellular Fire Communicator, Model(s) iPGSM-COM, IPGSM-DP Internet communicators, Model(s) 7845i-ent, 7845i-entF (c) Isolation modules, Model(s) ECP-Isolator, VPLEX-VSI Keyswitches, Model(s) 4146 (a) LCD keypads, Model(s) 6160CR-2, FA570CR Polling loop extender modules, Model(s) 4297 RF receivers, Model(s) 5881ENHC RF transceiver subassemblies, Model(s) 5883H Sensor Interface Module Gateway, Model(s) 472368 Supervised notification appliance modules, Model(s) 4204CF Transformers, Model(s) 1451 Universal group zoning multiplex modules, Model(s) 4209U Wireless transmitters, Model(s) 5817CB Zone expander modules, Model(s) 4190SN, 4193SN (b), 4193SNP (b) (a) - Must be installed adjacent to an alphanumeric (English language) keypad, Model 6160CR-2 when used as a fire alarm silencing switch. (b) - Must be mounted inside control panel cabinet or within a Listed junction box. Supervised Zone is required for Fire. Unsupervised Zone may be UOXX.S789 Control Unit Accessories, System Page Bottom See General Information for Control Unit Accessories, System HONEYWELL SECURITY S789 SUITE 100 2 CORPORATE CENTER DR PO BOX 9040 MELVILLE, NY 11747 USA Page 1of 2UOXX.S789 - Control Unit Accessories, System 8/30/2011http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=U... used for Burglary. (c) - For use with Model FOCUS 200 PLUS control unit. (d) - Keyswitch module must be installed adjacent to FSA unit if remote silence/reset desired. NOTE - Model numbers may include a prefix or suffix consisting of numbers and/or letters. For use with compatible Listed control unit systems as indicated in the installation instructions. Copyright © 2011 Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2011 Underwriters Laboratories Inc.®" Last Updated on 2011-07-18 Questions? Print this page Notice of Disclaimer Page Top Page 2of 2UOXX.S789 - Control Unit Accessories, System 8/30/2011http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=U... Insta ll a tion Instruction for Power S u pervisi o n Module x W"Of am- 011 UK ~ ~s ` ,~•T~ i POWER ~~nlol L mini01 LIEME 4 1111111 ~ii D ~ii~d01 ∎IUI ∎iU~~ a, mom 401C M°°r4e~CarRold 4012 pbWa1 lad aft. h"aiam 1 oa+w W*O •www I -+ 204-6V K40" 44W Moth 446N d~aelor -+ -+ r! %Tn'~~~ f~`Tn' ~~! I ~I POWER10 SUPERVISIONnow UNrr∎ I ∎ 1~Lz 00 ELECTRIC-AL VEC&r EM of UKDEVICE 204-12124V 204-12124V OF ELECTRICAL SPECIFICATIONSPower Supervision Unit 204 -6V Power Supervision Unit 204 -12124VOperating Voltage 5.1 - 15 VDC Operating Voltage 8.5 -33 VDCOperating Current 33 mA ® 6 VDC ;66 mA 0 12 VDC Operating Current 14 mA 0 12 VDC ;28 mA 0 24 VDCContact Rating (resistive) 2A 0 26 VDC or 115 VAC Contact Rating (resistive) 2 A 0 26 VDC or 115 VAC INSTALLATION INSTRUCTIONS 1 . Connect brown initiating leads as indicated such that the end of line 3 . Neatly dress wires and power supervision unit intodevice is connected in series with the power supervising contact. junction box .(see wiring diagram) 4 .Mount detector according to manufacturers installation2. Connect appropriate control leads as shown . Red incoming and red instructions .from module to terminal 1 . Black incoming and black from module toterminal2. o r , E S L nc .Corporate Headquarters: SeroW, Inc. ,esemn the •m12345 SW Leveton Drive dmvW specifications without nnodco .Tualatin, OR 97062P R O D U G ()F S E N T R O L INC 503-692-4052 U.S . & Canada: 800-547-2556 01904 s«*rd, inc.Technical Support: 800-648-7424 ®Printed on reoyilad paper E-se31o9¢10258 REV . 6 Installation Instructions secondary power Bell Circuit + - + -zone 01 zone 02 zone 03 zone 04 zone 06 zone 08 Testing: 405-05 ESL 405-05 Polarity Reversal RelayBurglar / Fire Alarm Control Alarm Output − + White/Black White/Red White Red Black ESL 400 Series Smoke Detectors with Sounders End of Line Device ESL 204-12/24V Power Supervision Relay Power Supply Alarm Loop − + − + − + Gray 405-05 Polarity Reversal Relay Module For use with 4-Wire Sounder Smoke Detectors and Fire/Burglar Alarm Control Panels Typical 405-05 Mounting Locations in the Control Panel ESL 405-05 Polarity Reversal Relay Module ESL 405-05 and 405-06 Relay Modules Installation Instructions UL LISTED CSFM Installation Instructions Specifications for 405-05 & 405-06 405-06 DPDT Relay Module For use as a Universal Switch Device Sentrol-Caddx reserves the right to change specifications without notice. ©2000 Sentrol-Caddx 12345 SW Leveton Dr., Tualatin, OR 97062 Tel.: 503.692.4052 Fax: 503.691.7566 http://www.sentrol.com U.S. & Canada: 800.547.2556 Technical Service: 800.648.7424 FaxBack: 1.800.483.2495 SENTROL-CADDX ESL a product of sentrol 12859 Rev B 07/00 - W hi t e + Gr a y NC NC COM NO COM NO White-Red Red White-Blue White-Black Black Blue ESL 405-06 DPDT Relay 1ESL 429/449 Description The ESL 429/449 Series low-profile, self-diagnostic, two-wire and four-wire smoke detectors work on the light scattering principle. A pulsed infrared light-emitting diode serves as the light source, and a high-speed photo-diode as the sensing element. This design has superior protection against false alarms caused by dust, insects, RF, and ambient light. These smoke detectors are especially suited for residential occupancies, including hotels, motels, and dormitories, as well as other commercial and industrial fire-system applications. This series is designed for two-wire and four-wire connection to 6-24 VDC fire alarm control panels, UL Listed for commercial or household fire protection. Features Self-diagnostics including automatic sensitivity testing. Each detector in the series continually monitors its own sensitivity and operational status (see Maintenance). A wide range of optional features are offered as shown in the Product Selection Guide. To provide for almost any application, these options include a built-in sounder, an auxiliary relay, an integral heat detector, and an isolated heat detector. ESL 429/449 Series Self-Diagnostic Photoelectric Smoke Detectors Installation Instructions Selecting a Location Selecting a suitable location is critical to the operation of smoke alarms. This equipment should be installed in accordance with the National Fire Protection Association’s (NFPA) Standard 72. See Figure 1. A-11-8.3.a Where to Locate the Required Smoke Alarms in Existing Construction. The major threat from fire in a family living unit occurs at night when everyone is asleep. The principal threat to persons in sleeping areas comes from fires in the remainder of the unit. Therefore, a smoke alarm(s) is best located between the bedroom areas and the rest of the unit. In units with only one bedroom area on one floor, the smoke alarm(s) should be located as shown in Figure 1 A. In family living units with more than one bedroom area or with more than one floor, more than one smoke alarm is required, as shown in Figure 1 B. In addition to smoke alarms outside of the sleeping areas, the installation of a smoke alarm on each additional story of the family living unit, including the basement, is required. These installations are shown in Figure 1 C. The living area smoke alarm should be installed in the living room or near the stairway to the upper level, or in both locations. The basement smoke alarm should be installed in close proximity to the stairway leading to the floor above. Where installed on an open-joisted ceiling, the alarm should be placed on the bottom of the joists. The alarm should be positioned relative to the stairway to intercept smoke coming from a fire in the basement before the smoke enters the stairway. Where to Locate the Required Smoke Alarms in New Construc- tion. All of the smoke alarms specified for existing construction are required and, in addition, a smoke alarm is required in each bedroom. California State Fire Marshal Approved MEA (New York City) Approved FM APPROVED Dining Room Basement Bedroom Bedroom Living Room = Required smoke alarms = Additional smoke alarms required for new construction Figure 1 . Detector Location C. Dining Room Kitchen Bedroom Bedroom Bedroom Living Room A. TV Room Dining Room KitchenBedroom Bedroom Bedroom Living Room B. g 2 ESL 429/449 Installation The detectors mount to standard single-gang electrical boxes, four-inch octagonal or four-inch square electrical boxes, or on WIREMOLD No. 5739 fixture boxes. The detectors may also be mounted directly to walls or ceilings where local codes/ jurisdictions permit. 1.Pull wire through the electrical box and connect to the plug-in terminal block supplied, one wire per terminal. See Figures 3 and 5. 2.Dress wiring neatly and snap the terminal block into the back of the detector. Note The detector cover must be closed completely, to sup- port the circuit board, while installing the terminal block. 3.Open the cover and mount the detector, using the mounting holes provided. See Figure 4. Note Positive air pressure from wire openings, conduit, mounting boxes, irregular mounting surfaces, or plenums causing air movement through and away from the detector may prevent proper operation. Seal all openings causing unwanted air flow using UL Listed expanding foam or Duxseal. 4.Remove the red plastic dust cover from the detector. The detectors are shipped with a dust cover for protection on construction sites with dusty environments. Figure 3. Plug-in Terminal Block Figure 4. Detector Mounting test switch 4” square or WIREMOLD mounting (No. 5739) mounting all boxes single gang 4” octagon mounting cover release Are More Smoke Alarms Desirable? The required number of smoke alarms might not provide reliable early warning protection for those areas separated by a door from the areas protected by the required smoke alarms. For this reason, it is recommended that the householder consider the use of additional smoke alarms for those areas for increased protection. The additional areas include the basement, bed- rooms, dining room, furnace room, utility room, and hallways not protected by the required smoke alarms. The installation of smoke alarms in kitchens, attics (finished or unfinished), or garages is not normally recommended, as these locations occasionally experience conditions that can result in improper operation. Important ! Regulations pertaining to smoke detector installations vary from state to state. For more information, contact your local fire department or local authority having jurisdiction. In addition to NFPA 72, use the following location guidelines to optimize performance and reduce the chance of false alarms: • Locate ceiling-mounted smoke detectors in the center of a room or hallway at least 4 inches (10cm) from any walls or partitions. •Locate wall-mounted smoke detectors so the top of the alarm is 4 to 12 inches (10 to 30cm) below the ceiling. See Figure 2. •When more than one detector is required, spacing of 30 feet (9m) may be used as a guide on smooth ceilings. Other spacing may be used depending on ceiling height, high air movement, and other conditions or response requirements. •Locate in a suitable environment as follows: - Temperature between 32°F (0°C) and 100°F (38°C) - Humidity between 0 and 95% non-condensing •Locate away from air conditioners, heating registers and any other ventilation source that may interfere with smoke entering the detector. •Locate away from kitchens, wood stoves, garages, furnaces, and bathrooms. •Mount smoke detectors on a firm permanent surface, typically a stud or metal runner. Note For instructions on removal of terminal block and circuit board, call technical services at 800-648-7424. Figure 2. Detector Placement ceiling acceptable here never here top of detector acceptable here side wall 4” (10cm) 4” (10cm) 12” (30cm) maximum Note Measurements shown are to the closest edge of the detector. 3ESL 429/449 Supervision of System Wiring Power wiring in four-wire systems is required by NFPA 72 to be supervised. This is accomplished by installing a power supervi- sion relay at the end of the detector power circuit. The contacts of the supervision relay are wired in series with the system’s alarm initiating circuit, and are closed when energized (see Figure 5). A break in the detector power circuit or a loss of power de-energizes the power supervision relay, opening the contacts and causing a trouble annunciation at the fire alarm control unit. ESL models 204-6 V and 204-12/24 V are relays UL Listed for four-wire power supervision. Models 449CTE and 449CSTE are smoke detectors with a built-in end-of-line power supervison relay, and can be used to supervise a circuit in place of a power supervison relay. The 449CTE and 449CSTE will also automati- cally send a trouble signal to the control panel whenever the detector needs maintenance. Installation Test After all connections are complete and the wiring is checked for errors, apply power to the system. There should be no alarm. If an alarm is reported, determine if a detector is latched in alarm or if there is a problem with the wiring. Smoke Test The units should be tested in place annually using one of the following methods: A. Use Smoke! in a can® and follow the directions on the can. B. Hold a smoldering punk or cotton wick close to the unit and gently direct the smoke into the smoke entry openings for 20 seconds or until an alarm is indicated. Be sure to properly extinguish the smoke source after testing! This is a go/no go test and is not a reliable indication of detector sensitivity. If it is successful, the LED will remain lit. To reset the detector, operate the system reset switch to remove power from the detectors. The control unit alarm and all auxiliary functions should be verified for a complete test of each detector. Heat Test Models with heat sensors sample for heat every 3 seconds. Test heat sensors by using a hot air gun. Aim the gun at the heat sensor from 6-10 inches (15-25cm) away. The detector should go into alarm in less than 30 seconds. + – ++--++-- 429 Series Wiring Diagram first detector last detector Compatible Listed Control Unit* fire alarm initiating circuit Models 429AT, 429C, 429CT, 429CST Model 429CRT power powernot usedauxiliary contacts End-of-Line Device * Two-Wire Compatibility Refer to ESL’s Compatibility Index for compatible control panel listings. 449 Series Wiring Diagram Figure 5. Wiring Diagrams + – ++--++--++-- first detector last detector fire alarm initiating circuit DC power circuit Listed Control Unit Power Supervision Unit power Models 449 CSRH* Models 449 CRT, CSRT Models 449 AT, C, CT, CST local non- latching smoke alarm contacts heat sensor contactspower alarm contacts auxiliary contactspower alarm contact red black brown brown * The 449CSRH units are smoke alarms with isolated heat detectors. End-of-Line Device 4 ESL 429/449 Figure 7. Sensitivity Testing magnet SQUE E Z E HER E LE D Figure 6. Detector Maintenance optical block chamber optical base indentation snap into indentation Maintenance The smoke detectors are designed for easy field service and maintenance. If a detector drifts beyond its approved sensitivity range for more than 24 hours, or fails internal diagnostic tests, the unit automatically indicates trouble by flashing its LED every second. This meets field sensitivity testing requirements without the need for external meters. Note Connect to a power supply that will not automatically reset. Since the self-diagnostics only indicate trouble after 27 hours, if the power supply automatically resets every 24 hours the self-diagnostic indication will never be signaled (the smoke detector will still signal alarm correctly). In accordance with NFPA 72, smoke detector sensitivity should be checked within one year after installation and every alternate year thereafter, in commercial installations, or every three years in residential sites. See Sensitivity Test. The detector’s replaceable optical block chamber unsnaps for easy field cleaning and service. Whenever the status LED indicates cleaning is necessary, follow these steps: 1.Open the detector cover, unsnap and throw away the optical block chamber. See Figure 6. 2.Thoroughly blow off the optical base and snap a new optical block chamber (part #211) back in place. Note Be sure the new optical block chamber is seated all the way down. 3.Close the detector cover and verify sensitivity. See Sensitivity Test. Approvals The smoke detectors are for use in commercial fire protective signaling systems and in household fire warning systems (NFPA 72). 429/449 Series Listed by Underwriter’s Laboratories; California State Fire Marshal approved (Listed # 7272-0447-128); MEA approved (New York City) (Listed # MEA 64-94-E) Factory Mutual approved. Sensitivity Test 1.Hold the magnet on the hinge side of the unit for more than one second (see Figure 7). The LED will flash 1 to 9 times. 2.Count the number of LED flashes, then use the following table to determine if any action is necessary. Flashes 0-1Indication:Unservicable hardware fault. Action:Reset and rerun sensitivity test. If the error persists, replace unit. 2-3Indication:Unit is becoming insensitive. Action:Clean and reset the unit. Rerun sensitivity test. If the error persists, replace the unit. 4-7Indication:Unit is within normal sensitivity range. Action:N/A 8-9Indication:Unit is becoming too sensitive. Action:Verify the optical chamber is snapped down securely. Clean the unit and replace the optical chamber. After the sequence of flashes, if the sensitivity is within limits and all other tests pass, the unit goes into alarm until reset by the panel. If the sensitivity is not within limits, or an unservice- able hardware fault is detected, the alarm LED will continue to flash once per second until the unit is reset by the panel. Note CSRH models auto reset. 5ESL 429/449 Warning! Limitations of Smoke Detectors Smoke detectors are very reliable, but may not work under all conditions. No smoke detector provides total protection of life or property. Smoke detectors are not a substitute for life insurance. Unreliable transmission or receiving of radio frequency (RF) signals may occur if the system is not installed, located, serviced and repaired properly. RF signals sent by this detector may be blocked or reflected by metal objects. Adjacent devices or systems using radio frequency signals may interfere with the operation of this alarm. Test the system often to be sure that signals are being sent and received properly. Smoke detectors may not be heard. A sound sleeper or someone who has taken drugs or alcohol may not awaken if the detector is installed outside a bedroom. Closed or partially closed doors and distance can block sound. This detector is not designed for the hearing impaired. Smoke detectors may not always activate and provide warning early enough. Smoke detectors only activate when enough smoke reaches the detector. If a fire starts in a chimney, wall, roof, on the other side of closed doors, or on a different level of the property enough smoke may not reach the detector for it to alarm. Smoke detectors are a significant help in reducing loss, injury and even death. However, no matter how good a detection device is, nothing works perfectly under every circumstance and we must warn you that you cannot expect a smoke detector to ensure that you will never suffer any damage or injury. Limited Warranty ESL is a brand of GE Security. The manufacturer warrants this smoke detector to be free from defects in material and workman- ship under conditions of normal use for a term of 3 years from the date of manufacture. During the warranty period, if a GE Security product or any of its components becomes defective, it will be repaired or replaced without charge. Out-of-warranty units will be repaired at the discretion of the manufacturer or, if not, a card will be forwarded to the customer suggesting a replacement unit and the cost of that unit. This warranty does not apply to units which have been subject to abuse, misuse, negligence or accident, or to which any modifica- tions, alterations or repairs have been made or attempted. This warranty is extended only to the original purchaser of the smoke detector and may be enforced only by such person. During the warranty period, if the detector or any warranted components thereof becomes defective, it will be replaced or repaired without charge at the manufacturer’s discretion if returned in accordance with the following instructions: Obtain a Return Authorization Number by calling 1-800-648-7422 or 503-692-4052, then carefully pack the detector in a well padded and insulated carton and return, postal charges prepaid to: Customer Service RMA# GE Security 12345 SW Leveton Drive Tualatin, OR 97062-9938 A note should be included advising the nature of the malfunction. Care must be exercised in the proper packing of detectors returned under this warranty as GE Security will not be responsible for warranty repairs to equipment damaged because of improper packing. The above warranty is in lieu of all other express warran- ties, and implied warranties of merchantability and fitness for a particular purpose are limited in duration for a period of THREE years from the date of manufacture. Under no circumstances shall manufacturer be liable to the pur- chaser or any other person for incidental or consequential damages of any nature, including without limitation damages for personal injury or damages to property, and however occasioned, whether alleged as resulting from breach of warranty by manufacturer, the negligence of manufacturer or otherwise. Manufacturer’s liability will in no event exceed the purchase price of the product. Some states do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so the above limitations and exclusions may not apply to you. Unless a longer period is required by applicable law, any action against manufac- turer in connection with this smoke detector must be commenced within one year after the cause of action has occurred. No agent, employee or representative of the Manufacturer nor any other person is authorized to modify this warranty in any respect. Repair or replacement as stated above is the exclusive remedy of the purchase hereunder. This warranty gives you specific legal rights and you also have other rights which vary from state to state. Planning for Emergencies Develop a plan to prepare for emergency situations. Discuss and rehearse your plan with everyone by doing a fire drill every few months. WARNING Do not enter a building where sirens are sounding Guidelines •Understand how to use your fire system. •Know the normal state of doors and windows: open, closed, or locked. •Escape fast! (Do not stop to pack.) •Use a different escape route if closed doors feel hot to the touch. •Crawl and hold your breath as much as possible to help reduce smoke inhalation during your escape. •Meet at a designated outdoor location. •Emphasize that no one should return to the premises if there is a fire. •Notify the fire department from a phone in another building. Your Floor Plan When establishing your escape routes, consider the following guidelines: •Have a drawing for each building level. •Show all exits (two exits per room are recommended). •Show the location of stairwells and fire escapes. •Show the location of all components of the fire system. •Show the locations of all fire extinguishers, hoses, ladders, etc. WARNING Smoke detectors CANNOT provide warnings for fires resulting from explosions, smoking in bed or other furniture, ignition of flammable liquids, vapors and gases, children playing with matches or lighters. Electrical Specifications Model 2-Wire 4-Wire Min.Volt. Max.Volt. Max. Ripple Typ.Avg.Stby. Typ. Alarm Cur. Typ.Avg. Pol. Alarm Relay Other Relay (PK to PK) Cur. (12-24V) (12-24V) Rev.Cur. Contacts Contacts (V) (uA) (mA) (mA) (A) (A) 429AT * 6.5 2010%70*see S09A --- 429C * 8.5 3310%70 *see S10A --- 429CT * 8.5 3310%70*see S10A --- 429CRT * 8.5 3310%70 *see S11A --2 429CST * 8.5 3310%70 *see S11A 10-- 449C * 8.5 3310%70 15 -0.5- 449CT * 8.5 3310%70 15 -0.5- 449CRT * 8.5 3310%70 31 -0.5- 449AT * 5.1 2710%70 15 -0.5- 449CST * 8.5 3310%70 40 100.5- 449CSRT * 8.5 3310%70 51 100.52 449CSRH ** * 8.5 3310%70 51 100.52 449CSTE * 8.5 3310%23mA 51 330.52 449CTE * 8.5 3310%23mA 31 230.52 Power Supervision Units ModelMin.Volt.Max. Volt.Typ. Avg. Stby.Cur.(uA)Relay Contacts (A) 204-6V (UL Listed) 5.1 1533mA @ 6VDC0.5 204-12/24V (UL Listed) 8.5 3314mA @ 12VDC, 28mA @ 24VDC0.5 Accessories SM-200 Smoke! in a can® canned smoke for functional testing of smoke detectors SM-EXT1 Smoke! in a can® extension accessory 211Replacement optical blocks (set of 10) 241Terminal block for 4-wire smoke detectors 449CTE, 449CSTE, 449AT, 449C, 449CT,449CST * 429 models draw up to a maximum of 60mA current if not limited by panel. ** 449CSRH model is a smoke alarm with isolated heat detector. Certain items in the installation instructions are protected under one or more of the following patents: 5,546,074; 5,798,701; 5,821,666; 6,756,906 Specifications Operating temperature......................32°F to 100°F (0°C to 38°C) Operating humidity range.......................0 to 95% non-condensing Sounder specifications............................................85dB at 10 feet Field wiring size............................................................14-24 AWG Self-diagnostic indication ..................typically 27 hours after reset (do not connect power supply that resets every 24 hours) Heat detector..................fixed temp 135°F, 50 foot (15m) spacing rate-of-rise 15°F/min > 105°F (8°C/min > 41°C) Auxiliary relay contacts........2A @ 28VDC or 120VAC (resistive) Alarm contacts..................................500mA @ 36VDC (resistive) Dimensions .................6.1” (15.5cm) diameter x 1.9” (4.7cm) deep Weight.....................................................................8.8 oz. (0.25kg) Color .......................................................................................white Wire Type Model Designator Power Designator Number DescriptionDesignator ListingDesignator Power 2 Two-wire only 9 UL A 6/12 VDC 4 Four-wire only C 12/24 VDC Product Selection Guide 449CSRT Series Designator Model Designator Wire Type Power Designator Features Features DesignatorFeatureDescription EEnd-of-Line Power Built-in end-of-line relay that also acts as a sensitivity status output. For four-wire only. Fail-safe Supervisory andrelay trips upon loss of power or if smoke detector is outside the approved sensitivity range for Sensitivity Status more than one day. End-of-line resistor is easily connected to terminal with no extra wiring, or Relay relay contacts can be connected to a separate trouble loop. HIsolated Fixed Temp.Isolated fixed 135°F (57°C) and rate-of-rise heat detector, independently trips the LED and alarm and Rate-of-Riserelay output. Smoke detector activates internal sounder (local alarm) and auxiliary relay, but does Heat Detectornot latch. Approved as both single station smoke alarm and system heat detector. RAuxiliary Relay Used to activate other devices such as elevator recall, door holders, etc. UL Listed for releasing services. SBuilt-in Sounder85db built-in sounder alarms when smoke is detected or when power wiring polarity is reversed. TIntegrated Fixed Temp.Integrated fixed 135°F (57°C) temp. and rate-of-rise heat detector offers double protection. and Rate-of-RiseEither heat detector or smoke detector can trip and latch LED and alarm relay outputs. Heat Detector GE Security 12345 SW Leveton Drive Tualatin, OR 97062 503-692-4052 USA & Canada: 800-547-2556 Tech Support: 800-648-7424 www.ge-security.com 14153D / September 2004 ______________________________________________________________________________________ Security, Fire, CCTV, Access Control, Custom Audio/Video, and Automation ______________________________________________________________________________________ Post Office Box 4910  Edwards, Colorado 81632  Phone (970) 926-8788  Fax (970) 926-8790 www.superioralarmco.com  admin@superioralarmco.com May 29, 2012 Department of Community Development 75 South Frontage Road Vail, Colorado 81657 RE: 352 Beaver Dam Circle, Unit-A, Contact Information Premise Phone #970-476-5534 Response Party 1: Amy Byers – Holm – Cell Phone #970-376-2489 Response Party 2: Claes Holm – Cell Phone #970-390-1315 Daniel Dimitrov NCET II Fire Alarms Cert. #119879 ______________________________________________________________________________________ Security, Fire, CCTV, Access Control, Custom Audio/Video, and Automation ______________________________________________________________________________________ Post Office Box 4910  Edwards, Colorado 81632  Phone (970) 926-8788  Fax (970) 926-8790 www.superioralarmco.com  admin@superioralarmco.com May 29, 2012 Department of Community Development 75 South Frontage Road Vail, Colorado 81657 RE: 352 Beaver Dam Circle, Unit-A Device List. 1. 1x Ademco Vista 128-SIA – addressable fire alarm control panel. 2. 2x Ademco 6160 – alpha keypad. 3. 1x Ademco 4204 – relay module. 4. 17x Ademco 4193SN – Point ID serialized interface module. 5. 3x Sustem Sensor BK-CI1224T – hardwired carbon monoxide detector. 6. 11x ESL449CST – 4 wire photo-electric smoke detector with built in mini sounder. 7. 1x ESL 405-05 – polarity reversal module. 8. 1x ESL – 204-12/24V – power supervision module. 9. 6x System Sensor BK5603 –1350 F fixed temp heat detector. 10. 1x System Sensor MHW –mini horn in white. 11. 1x Knox 3724 – recessed key vault. 12. Belden B5322UL – 18AWG, 4 conductor fire wire. Daniel Dimitrov NCET II Fire Alarms Cert. #119879 ______________________________________________________________________________________ Security, Fire, CCTV, Access Control, Custom Audio/Video, and Automation ______________________________________________________________________________________ Post Office Box 4910  Edwards, Colorado 81632  Phone (970) 926-8788  Fax (970) 926-8790 www.superioralarmco.com  admin@superioralarmco.com May 29, 2012 Department of Community Development 75 South Frontage Road Vail, Colorado 81657 RE: 352 Beaver Dam Circle, Unit-A, Monitoring Information Monitoring Method – Digital Alarm Communicator. Monitoring Agency – Central Security Station, Greely CO. Daniel Dimitrov NCET II Fire Alarms Cert. #119879 ______________________________________________________________________________________ Security, Fire, CCTV, Access Control, Custom Audio/Video, and Automation ______________________________________________________________________________________ Post Office Box 4910  Edwards, Colorado 81632  Phone (970) 926-8788  Fax (970) 926-8790 www.superioralarmco.com  admin@superioralarmco.com May 29, 2012 Department of Community Development 75 South Frontage Road Vail, Colorado 81657 RE: 352 Beaver Dam Circle Scope of Work Letter Scope of work at 325 Beaver Dam Circle, Unit-A consists of the following: 1. Replace the existing FACP with addressable Ademco Vista 128-SIA; 2. Replace existing 2 annunciators with Ademco compatible 6160; 3. Add a hard wired horn in the garage; 4. Replace the existing heat detectors with 1350 F fixed temp ones; 5. Relocate existing smoke detector in the living room closer to the peak of the ceiling – east; 6. Add a hard wired smoke detector to the west peak of the ceiling; 7. Add a hardwired smoke detector in the mud room; 8. Add a hardwired heat detector in the laundry room; 9. Add two hardwired heat detectors in the crawl space; 10. Add two smoke detectors in the bedrooms on the lower level; 11. Add two smoke detectors in the new family room and main level bedroom; 12. Add a smoke detector in the new upper level bedroom; 13. Add three hardwired carbon monoxide detectors adjacent to the sleeping areas on the lower, main and upper levels; 14. Install a Knox Box to the right of the garage over-head door. Daniel Dimitrov NCET II Fire Alarms Cert. #119879 ______________________________________________________________________________________ Security, Fire, CCTV, Access Control, Custom Audio/Video, and Automation ______________________________________________________________________________________ Post Office Box 4910  Edwards, Colorado 81632  Phone (970) 926-8788  Fax (970) 926-8790 www.superioralarmco.com  admin@superioralarmco.com May 29, 2012 Department of Community Development 75 South Frontage Road Vail, Colorado 81657 RE: 352 Beaver Dam Circle, Fire Zones Information 1. Lower Level West Entrance 2. Lower Level Crawl East 3. Lower Level Crawl West 4. Lower Level Laundry Room 5. Lower Level West Mechanical Room 6. Lower Level Hallway 7. Lower Level East Bedroom 8. Lower Level West Bedroom 9. Lower Level Storage Under Stairs 10. Lower Level Garage 11. Main Level Living Room East 12. Main Level Living room West 13. Main Level Kitchen 14. Main Level South Family Room 15. Main Level South Bedroom 16. Upper Level West Loft 17. Upper Level South Bedroom 18. Lower Level Hallway CO Detection 19. Main Level O/S Bedroom CO detection 20. Upper Level Sleeping Area CO Detecetion Daniel Dimitrov NCET II Fire Alarms Cert. #119879 6160 ALPHA DISPLAY KEYPAD CO06010 L/6160/D September 2006 © 2006 Honeywell International Inc. Honeywell Security & Custom Electronics Honeywell International Inc. PO Box 9035 Syosset, NY 11791 www.honeywell.com ORDERING 6160 Alpha Display Keypad The 6160 Deluxe Keypad is easy to install and simple to use. The attractive white console blends with any décor and features a contoured, removable door that conceals illuminated soft-touch keys. The 6160 also features a new larger and brighter 32-character display with easy-to-read plain-English status messages. The oversized function keys are easily accessed even when the keypad door is closed, and can be programmed for fire, burglary, personal emergencies and other operations. Colored self-adhesive labels are included. • Large, easy-to-use keypad • Keys continuously backlit for greater visibility • Speaker with audible beeps to indicate: - System status - Entry/exit delay - Other alarm situations • Zones and system events displayed in plain English • No confusing blinking lights • Four programmable function keys • System functions clearly labeled • Functions performed by just entering security code plus command • White with removable door blends with any décor FEATURES Physical • 5-5/16"H x 7-3/8"W x 1-3/16"D (135mm x 190mm x 30mm) Current • Standby-40mA • Activated Transmission-160mA Wiring • - (Black):Ground • + (Red):+12 VDC (Aux. Power) • D1 (Green):“Data in” to control panel • D0 (Yellow):“Data out” from control panel Compatibility • Fully compatible with all VISTA controls. SPECIFICATIONS WITH DOOR ATTACHED WITHOUT DOOR K3590-ADV2 4/04 Rev. A ADEMCO 6150 & 6160 REMOTE KEYPADS INSTALLATION AND SETUP GUIDE Keypad Features ADEMCO 6150 Fixed-Word ADEMCO 6160 2-Line Alpha Backlit Display YES (see note) YES (see note) Dedicated Function Keys YES YES Built-in Sounder Piezo Speaker Note: Permanent display backlighting is an option on some controls (see the control's instructions for details). GENERAL INFORMATIONWIRING AND INSTALLATION The ADEMCO 6150 and ADEMCO 6160 are addressable Remote Keypads designed for use with ADEMCO control panels. Addresses are set via the keypad keys. The keys on the keypads are continuously backlit for convenience. KEYPAD DISPLAYS AND LEDS The keypads have the following display features: Model Fixed Word Display 2-line Alpha Display 2-digit Zone Identifier Custom Zone Descriptors 6150 X X 6160 X X The following table shows the LEDs and their functions: LED Function Red Lights when the system is armed in any mode Green Lights when the system is "ready" to be armed. SPECIAL FUNCTION KEYS The keypads also feature function keys. These keys may be programmed for panic alarms or other special functions such as macros. See the control's instructions for details. The keypads can be surface mounted directly to a drywall, or to a single- or double-gang electrical box. 1.Remove the case back by pushing down two "snaps." See diagram below. 2.Route wiring from the control panel through the opening in the case back. 3.Mount the case back to a wall or electrical box. 4.Wire directly from the keypad’s terminal block to the terminal block on the control board as follows: Wiring Table (All Keypads) Keypad Control Panel Wire Color GData InGreen –– Aux Pwr (GND)Black ++ Aux. PwrRed YData OutYellow See the control panel’s Installation and Setup Guide for more complete details. 5.Reattach the keypad to its case back. RETAINING SNAPS NOTE: TO REMOVE CASE BACK PUSH IN THE TWO MOUNTING SNAPS LOCATED ALONG THE BOTTOM OF THE KEYPAD AND LIFT UP. 61 5 0 - 0 0 6 - V 0 ARMED READYFunction keys must be held down for at least 2 seconds to activate an alarm, key pairs activate immediately. Function Keys A or [1] and [✱] B or [✱] and [#] C or [3] and [#] D ÊK3590-ADV2KŠ K3590-ADV2 4/04 Rev. A SETTING THE KEYPAD ADDRESSFUNCTION KEY LABELS The keypad can either be set for an address of 00-30, or to the non-addressable mode (31). The keypad's default address is 31. To change the keypad's address, do the following: 1. Enter address mode: Power up the keypad. Within 60 seconds of power-up, press and hold down the [1] and [3] keys at the same time for 3 seconds. (If unable to enter address mode, power up and try again.) The current keypad address will be displayed, and the cursor will be under the "tens" digit. If 10 seconds have passed with no key entry, the keypad automatically exits address mode. You must power down, power up and start address mode again. NOTE: The keypad will not enter address mode if the panel to which it is connected is in programming mode. 2. Set the current address to "00": Press [0] to clear the current "tens" digit. The cursor will move to the "ones" digit position. Press [0] to clear the current "ones" digit. The cursor will move back to the "tens" digit position. 3. Enter the keypad's address: Enter the proper "tens" digit of the keypad's address. The cursor will move to the "ones" digit position. Enter the proper "ones" digit of the keypad's address. Note that address "31" sets the keypad to non-addressable mode. 4. Exit address mode: Press [✱] to save the displayed address and exit address mode. VIEWING THE KEYPAD ADDRESS Press and hold down the [1] and [3] keys at the same time for about 3 seconds. The current address is displayed. No key entry is allowed. Press any key to exit or wait 10 seconds to exit viewing mode. A set of adhesive-backed labels with some typical function symbols (i.e., fire, police, personal emergency, etc.) is provided. These labels can be placed on or next to the keys to identify each key's function for the end user (as determined by the control panel's capability and programming; see the control's instructions). SPECIFICATIONS Physical: 6150: 4-7/8"H x 6-1/4"W x 1"D 6160: 5-5/16"H x 7-3/8"W x 1-3/16"D Displays: 6150: Fixed-Word LCD (backlit). 6160: 2 x 16 alpha-numeric supertwist LCD, backlit. Sounder: 6150: Piezo-electric (fire alarm is loud, pulsing single tone; (all Keypads) burglary alarm is loud, continuous, dual tone). 6160: Speaker. Voltage: 12VDC Current: 6150: 70mA (ARMED LED lit, LCD backlight and sounder on), reduces to 40mA when panel is operating in standby mode (backlight off). 6160: 150mA (ARMED LED lit, LCD backlight and sounder on), reduces to 40mA when panel is operating in standby mode (backlight off). REFER TO INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM. 165 Eileen Way, Syosset, New York 11791 Copyright© 2004 Honeywell International Inc. www.honeywell.com/security Control Unit Accessories, System Backup dialer modules, Model(s) 5140DLM Eight-zone remote point Class A interface modules, Model(s) 4208SNF Eight-zone remote point modules, Model(s) 4208SN, 4208U Enclosures, Model(s) 5800BOX End-of-line resistors, Model(s) 4100EOLR, EOL100, EOL20, EOL22, EOL82, EOLR470K Fire system annunciator keyswitch modules, Model(s) FSAKSM (d) Fire system annunciator modules, Model(s) FSA-24F, FSA-8F Internet and Digital Cellular Fire Communicator, Model(s) iPGSM-COM, IPGSM-DP Internet communicators, Model(s) 7845i-ent, 7845i-entF (c) Isolation modules, Model(s) ECP-Isolator, VPLEX-VSI Keyswitches, Model(s) 4146 (a) LCD keypads, Model(s) 6160CR-2, FA570CR Polling loop extender modules, Model(s) 4297 RF receivers, Model(s) 5881ENHC RF transceiver subassemblies, Model(s) 5883H Sensor Interface Module Gateway, Model(s) 472368 Supervised notification appliance modules, Model(s) 4204CF Transformers, Model(s) 1451 Universal group zoning multiplex modules, Model(s) 4209U Wireless transmitters, Model(s) 5817CB Zone expander modules, Model(s) 4190SN, 4193SN (b), 4193SNP (b) (a) - Must be installed adjacent to an alphanumeric (English language) keypad, Model 6160CR-2 when used as a fire alarm silencing switch. (b) - Must be mounted inside control panel cabinet or within a Listed junction box. Supervised Zone is required for Fire. Unsupervised Zone may be UOXX.S789 Control Unit Accessories, System Page Bottom See General Information for Control Unit Accessories, System HONEYWELL SECURITY S789 SUITE 100 2 CORPORATE CENTER DR PO BOX 9040 MELVILLE, NY 11747 USA Page 1of 2UOXX.S789 - Control Unit Accessories, System 8/30/2011http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=U... used for Burglary. (c) - For use with Model FOCUS 200 PLUS control unit. (d) - Keyswitch module must be installed adjacent to FSA unit if remote silence/reset desired. NOTE - Model numbers may include a prefix or suffix consisting of numbers and/or letters. For use with compatible Listed control unit systems as indicated in the installation instructions. Copyright © 2011 Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2011 Underwriters Laboratories Inc.®" Last Updated on 2011-07-18 Questions? Print this page Notice of Disclaimer Page Top Page 2of 2UOXX.S789 - Control Unit Accessories, System 8/30/2011http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=U... Insta ll a tion Instruction for Power S u pervisi o n Module x W"Of am- 011 UK ~ ~s ` ,~•T~ i POWER ~~nlol L mini01 LIEME 4 1111111 ~ii D ~ii~d01 ∎IUI ∎iU~~ a, mom 401C M°°r4e~CarRold 4012 pbWa1 lad aft. h"aiam 1 oa+w W*O •www I -+ 204-6V K40" 44W Moth 446N d~aelor -+ -+ r! %Tn'~~~ f~`Tn' ~~! I ~I POWER10 SUPERVISIONnow UNrr∎ I ∎ 1~Lz 00 ELECTRIC-AL VEC&r EM of UKDEVICE 204-12124V 204-12124V OF ELECTRICAL SPECIFICATIONSPower Supervision Unit 204 -6V Power Supervision Unit 204 -12124VOperating Voltage 5.1 - 15 VDC Operating Voltage 8.5 -33 VDCOperating Current 33 mA ® 6 VDC ;66 mA 0 12 VDC Operating Current 14 mA 0 12 VDC ;28 mA 0 24 VDCContact Rating (resistive) 2A 0 26 VDC or 115 VAC Contact Rating (resistive) 2 A 0 26 VDC or 115 VAC INSTALLATION INSTRUCTIONS 1 . Connect brown initiating leads as indicated such that the end of line 3 . Neatly dress wires and power supervision unit intodevice is connected in series with the power supervising contact. junction box .(see wiring diagram) 4 .Mount detector according to manufacturers installation2. Connect appropriate control leads as shown . Red incoming and red instructions .from module to terminal 1 . Black incoming and black from module toterminal2. o r , E S L nc .Corporate Headquarters: SeroW, Inc. ,esemn the •m12345 SW Leveton Drive dmvW specifications without nnodco .Tualatin, OR 97062P R O D U G ()F S E N T R O L INC 503-692-4052 U.S . & Canada: 800-547-2556 01904 s«*rd, inc.Technical Support: 800-648-7424 ®Printed on reoyilad paper E-se31o9¢10258 REV . 6 Installation Instructions secondary power Bell Circuit + - + -zone 01 zone 02 zone 03 zone 04 zone 06 zone 08 Testing: 405-05 ESL 405-05 Polarity Reversal RelayBurglar / Fire Alarm Control Alarm Output − + White/Black White/Red White Red Black ESL 400 Series Smoke Detectors with Sounders End of Line Device ESL 204-12/24V Power Supervision Relay Power Supply Alarm Loop − + − + − + Gray 405-05 Polarity Reversal Relay Module For use with 4-Wire Sounder Smoke Detectors and Fire/Burglar Alarm Control Panels Typical 405-05 Mounting Locations in the Control Panel ESL 405-05 Polarity Reversal Relay Module ESL 405-05 and 405-06 Relay Modules Installation Instructions UL LISTED CSFM Installation Instructions Specifications for 405-05 & 405-06 405-06 DPDT Relay Module For use as a Universal Switch Device Sentrol-Caddx reserves the right to change specifications without notice. ©2000 Sentrol-Caddx 12345 SW Leveton Dr., Tualatin, OR 97062 Tel.: 503.692.4052 Fax: 503.691.7566 http://www.sentrol.com U.S. & Canada: 800.547.2556 Technical Service: 800.648.7424 FaxBack: 1.800.483.2495 SENTROL-CADDX ESL a product of sentrol 12859 Rev B 07/00 - W hi t e + Gr a y NC NC COM NO COM NO White-Red Red White-Blue White-Black Black Blue ESL 405-06 DPDT Relay 1ESL 429/449 Description The ESL 429/449 Series low-profile, self-diagnostic, two-wire and four-wire smoke detectors work on the light scattering principle. A pulsed infrared light-emitting diode serves as the light source, and a high-speed photo-diode as the sensing element. This design has superior protection against false alarms caused by dust, insects, RF, and ambient light. These smoke detectors are especially suited for residential occupancies, including hotels, motels, and dormitories, as well as other commercial and industrial fire-system applications. This series is designed for two-wire and four-wire connection to 6-24 VDC fire alarm control panels, UL Listed for commercial or household fire protection. Features Self-diagnostics including automatic sensitivity testing. Each detector in the series continually monitors its own sensitivity and operational status (see Maintenance). A wide range of optional features are offered as shown in the Product Selection Guide. To provide for almost any application, these options include a built-in sounder, an auxiliary relay, an integral heat detector, and an isolated heat detector. ESL 429/449 Series Self-Diagnostic Photoelectric Smoke Detectors Installation Instructions Selecting a Location Selecting a suitable location is critical to the operation of smoke alarms. This equipment should be installed in accordance with the National Fire Protection Association’s (NFPA) Standard 72. See Figure 1. A-11-8.3.a Where to Locate the Required Smoke Alarms in Existing Construction. The major threat from fire in a family living unit occurs at night when everyone is asleep. The principal threat to persons in sleeping areas comes from fires in the remainder of the unit. Therefore, a smoke alarm(s) is best located between the bedroom areas and the rest of the unit. In units with only one bedroom area on one floor, the smoke alarm(s) should be located as shown in Figure 1 A. In family living units with more than one bedroom area or with more than one floor, more than one smoke alarm is required, as shown in Figure 1 B. In addition to smoke alarms outside of the sleeping areas, the installation of a smoke alarm on each additional story of the family living unit, including the basement, is required. These installations are shown in Figure 1 C. The living area smoke alarm should be installed in the living room or near the stairway to the upper level, or in both locations. The basement smoke alarm should be installed in close proximity to the stairway leading to the floor above. Where installed on an open-joisted ceiling, the alarm should be placed on the bottom of the joists. The alarm should be positioned relative to the stairway to intercept smoke coming from a fire in the basement before the smoke enters the stairway. Where to Locate the Required Smoke Alarms in New Construc- tion. All of the smoke alarms specified for existing construction are required and, in addition, a smoke alarm is required in each bedroom. California State Fire Marshal Approved MEA (New York City) Approved FM APPROVED Dining Room Basement Bedroom Bedroom Living Room = Required smoke alarms = Additional smoke alarms required for new construction Figure 1 . Detector Location C. Dining Room Kitchen Bedroom Bedroom Bedroom Living Room A. TV Room Dining Room KitchenBedroom Bedroom Bedroom Living Room B. g 2 ESL 429/449 Installation The detectors mount to standard single-gang electrical boxes, four-inch octagonal or four-inch square electrical boxes, or on WIREMOLD No. 5739 fixture boxes. The detectors may also be mounted directly to walls or ceilings where local codes/ jurisdictions permit. 1.Pull wire through the electrical box and connect to the plug-in terminal block supplied, one wire per terminal. See Figures 3 and 5. 2.Dress wiring neatly and snap the terminal block into the back of the detector. Note The detector cover must be closed completely, to sup- port the circuit board, while installing the terminal block. 3.Open the cover and mount the detector, using the mounting holes provided. See Figure 4. Note Positive air pressure from wire openings, conduit, mounting boxes, irregular mounting surfaces, or plenums causing air movement through and away from the detector may prevent proper operation. Seal all openings causing unwanted air flow using UL Listed expanding foam or Duxseal. 4.Remove the red plastic dust cover from the detector. The detectors are shipped with a dust cover for protection on construction sites with dusty environments. Figure 3. Plug-in Terminal Block Figure 4. Detector Mounting test switch 4” square or WIREMOLD mounting (No. 5739) mounting all boxes single gang 4” octagon mounting cover release Are More Smoke Alarms Desirable? The required number of smoke alarms might not provide reliable early warning protection for those areas separated by a door from the areas protected by the required smoke alarms. For this reason, it is recommended that the householder consider the use of additional smoke alarms for those areas for increased protection. The additional areas include the basement, bed- rooms, dining room, furnace room, utility room, and hallways not protected by the required smoke alarms. The installation of smoke alarms in kitchens, attics (finished or unfinished), or garages is not normally recommended, as these locations occasionally experience conditions that can result in improper operation. Important ! Regulations pertaining to smoke detector installations vary from state to state. For more information, contact your local fire department or local authority having jurisdiction. In addition to NFPA 72, use the following location guidelines to optimize performance and reduce the chance of false alarms: • Locate ceiling-mounted smoke detectors in the center of a room or hallway at least 4 inches (10cm) from any walls or partitions. •Locate wall-mounted smoke detectors so the top of the alarm is 4 to 12 inches (10 to 30cm) below the ceiling. See Figure 2. •When more than one detector is required, spacing of 30 feet (9m) may be used as a guide on smooth ceilings. Other spacing may be used depending on ceiling height, high air movement, and other conditions or response requirements. •Locate in a suitable environment as follows: - Temperature between 32°F (0°C) and 100°F (38°C) - Humidity between 0 and 95% non-condensing •Locate away from air conditioners, heating registers and any other ventilation source that may interfere with smoke entering the detector. •Locate away from kitchens, wood stoves, garages, furnaces, and bathrooms. •Mount smoke detectors on a firm permanent surface, typically a stud or metal runner. Note For instructions on removal of terminal block and circuit board, call technical services at 800-648-7424. Figure 2. Detector Placement ceiling acceptable here never here top of detector acceptable here side wall 4” (10cm) 4” (10cm) 12” (30cm) maximum Note Measurements shown are to the closest edge of the detector. 3ESL 429/449 Supervision of System Wiring Power wiring in four-wire systems is required by NFPA 72 to be supervised. This is accomplished by installing a power supervi- sion relay at the end of the detector power circuit. The contacts of the supervision relay are wired in series with the system’s alarm initiating circuit, and are closed when energized (see Figure 5). A break in the detector power circuit or a loss of power de-energizes the power supervision relay, opening the contacts and causing a trouble annunciation at the fire alarm control unit. ESL models 204-6 V and 204-12/24 V are relays UL Listed for four-wire power supervision. Models 449CTE and 449CSTE are smoke detectors with a built-in end-of-line power supervison relay, and can be used to supervise a circuit in place of a power supervison relay. The 449CTE and 449CSTE will also automati- cally send a trouble signal to the control panel whenever the detector needs maintenance. Installation Test After all connections are complete and the wiring is checked for errors, apply power to the system. There should be no alarm. If an alarm is reported, determine if a detector is latched in alarm or if there is a problem with the wiring. Smoke Test The units should be tested in place annually using one of the following methods: A. Use Smoke! in a can® and follow the directions on the can. B. Hold a smoldering punk or cotton wick close to the unit and gently direct the smoke into the smoke entry openings for 20 seconds or until an alarm is indicated. Be sure to properly extinguish the smoke source after testing! This is a go/no go test and is not a reliable indication of detector sensitivity. If it is successful, the LED will remain lit. To reset the detector, operate the system reset switch to remove power from the detectors. The control unit alarm and all auxiliary functions should be verified for a complete test of each detector. Heat Test Models with heat sensors sample for heat every 3 seconds. Test heat sensors by using a hot air gun. Aim the gun at the heat sensor from 6-10 inches (15-25cm) away. The detector should go into alarm in less than 30 seconds. + – ++--++-- 429 Series Wiring Diagram first detector last detector Compatible Listed Control Unit* fire alarm initiating circuit Models 429AT, 429C, 429CT, 429CST Model 429CRT power powernot usedauxiliary contacts End-of-Line Device * Two-Wire Compatibility Refer to ESL’s Compatibility Index for compatible control panel listings. 449 Series Wiring Diagram Figure 5. Wiring Diagrams + – ++--++--++-- first detector last detector fire alarm initiating circuit DC power circuit Listed Control Unit Power Supervision Unit power Models 449 CSRH* Models 449 CRT, CSRT Models 449 AT, C, CT, CST local non- latching smoke alarm contacts heat sensor contactspower alarm contacts auxiliary contactspower alarm contact red black brown brown * The 449CSRH units are smoke alarms with isolated heat detectors. End-of-Line Device 4 ESL 429/449 Figure 7. Sensitivity Testing magnet SQUE E Z E HER E LE D Figure 6. Detector Maintenance optical block chamber optical base indentation snap into indentation Maintenance The smoke detectors are designed for easy field service and maintenance. If a detector drifts beyond its approved sensitivity range for more than 24 hours, or fails internal diagnostic tests, the unit automatically indicates trouble by flashing its LED every second. This meets field sensitivity testing requirements without the need for external meters. Note Connect to a power supply that will not automatically reset. Since the self-diagnostics only indicate trouble after 27 hours, if the power supply automatically resets every 24 hours the self-diagnostic indication will never be signaled (the smoke detector will still signal alarm correctly). In accordance with NFPA 72, smoke detector sensitivity should be checked within one year after installation and every alternate year thereafter, in commercial installations, or every three years in residential sites. See Sensitivity Test. The detector’s replaceable optical block chamber unsnaps for easy field cleaning and service. Whenever the status LED indicates cleaning is necessary, follow these steps: 1.Open the detector cover, unsnap and throw away the optical block chamber. See Figure 6. 2.Thoroughly blow off the optical base and snap a new optical block chamber (part #211) back in place. Note Be sure the new optical block chamber is seated all the way down. 3.Close the detector cover and verify sensitivity. See Sensitivity Test. Approvals The smoke detectors are for use in commercial fire protective signaling systems and in household fire warning systems (NFPA 72). 429/449 Series Listed by Underwriter’s Laboratories; California State Fire Marshal approved (Listed # 7272-0447-128); MEA approved (New York City) (Listed # MEA 64-94-E) Factory Mutual approved. Sensitivity Test 1.Hold the magnet on the hinge side of the unit for more than one second (see Figure 7). The LED will flash 1 to 9 times. 2.Count the number of LED flashes, then use the following table to determine if any action is necessary. Flashes 0-1Indication:Unservicable hardware fault. Action:Reset and rerun sensitivity test. If the error persists, replace unit. 2-3Indication:Unit is becoming insensitive. Action:Clean and reset the unit. Rerun sensitivity test. If the error persists, replace the unit. 4-7Indication:Unit is within normal sensitivity range. Action:N/A 8-9Indication:Unit is becoming too sensitive. Action:Verify the optical chamber is snapped down securely. Clean the unit and replace the optical chamber. After the sequence of flashes, if the sensitivity is within limits and all other tests pass, the unit goes into alarm until reset by the panel. If the sensitivity is not within limits, or an unservice- able hardware fault is detected, the alarm LED will continue to flash once per second until the unit is reset by the panel. Note CSRH models auto reset. 5ESL 429/449 Warning! Limitations of Smoke Detectors Smoke detectors are very reliable, but may not work under all conditions. No smoke detector provides total protection of life or property. Smoke detectors are not a substitute for life insurance. Unreliable transmission or receiving of radio frequency (RF) signals may occur if the system is not installed, located, serviced and repaired properly. RF signals sent by this detector may be blocked or reflected by metal objects. Adjacent devices or systems using radio frequency signals may interfere with the operation of this alarm. Test the system often to be sure that signals are being sent and received properly. Smoke detectors may not be heard. A sound sleeper or someone who has taken drugs or alcohol may not awaken if the detector is installed outside a bedroom. Closed or partially closed doors and distance can block sound. This detector is not designed for the hearing impaired. Smoke detectors may not always activate and provide warning early enough. Smoke detectors only activate when enough smoke reaches the detector. If a fire starts in a chimney, wall, roof, on the other side of closed doors, or on a different level of the property enough smoke may not reach the detector for it to alarm. Smoke detectors are a significant help in reducing loss, injury and even death. However, no matter how good a detection device is, nothing works perfectly under every circumstance and we must warn you that you cannot expect a smoke detector to ensure that you will never suffer any damage or injury. Limited Warranty ESL is a brand of GE Security. The manufacturer warrants this smoke detector to be free from defects in material and workman- ship under conditions of normal use for a term of 3 years from the date of manufacture. During the warranty period, if a GE Security product or any of its components becomes defective, it will be repaired or replaced without charge. Out-of-warranty units will be repaired at the discretion of the manufacturer or, if not, a card will be forwarded to the customer suggesting a replacement unit and the cost of that unit. This warranty does not apply to units which have been subject to abuse, misuse, negligence or accident, or to which any modifica- tions, alterations or repairs have been made or attempted. This warranty is extended only to the original purchaser of the smoke detector and may be enforced only by such person. During the warranty period, if the detector or any warranted components thereof becomes defective, it will be replaced or repaired without charge at the manufacturer’s discretion if returned in accordance with the following instructions: Obtain a Return Authorization Number by calling 1-800-648-7422 or 503-692-4052, then carefully pack the detector in a well padded and insulated carton and return, postal charges prepaid to: Customer Service RMA# GE Security 12345 SW Leveton Drive Tualatin, OR 97062-9938 A note should be included advising the nature of the malfunction. Care must be exercised in the proper packing of detectors returned under this warranty as GE Security will not be responsible for warranty repairs to equipment damaged because of improper packing. The above warranty is in lieu of all other express warran- ties, and implied warranties of merchantability and fitness for a particular purpose are limited in duration for a period of THREE years from the date of manufacture. Under no circumstances shall manufacturer be liable to the pur- chaser or any other person for incidental or consequential damages of any nature, including without limitation damages for personal injury or damages to property, and however occasioned, whether alleged as resulting from breach of warranty by manufacturer, the negligence of manufacturer or otherwise. Manufacturer’s liability will in no event exceed the purchase price of the product. Some states do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so the above limitations and exclusions may not apply to you. Unless a longer period is required by applicable law, any action against manufac- turer in connection with this smoke detector must be commenced within one year after the cause of action has occurred. No agent, employee or representative of the Manufacturer nor any other person is authorized to modify this warranty in any respect. Repair or replacement as stated above is the exclusive remedy of the purchase hereunder. This warranty gives you specific legal rights and you also have other rights which vary from state to state. Planning for Emergencies Develop a plan to prepare for emergency situations. Discuss and rehearse your plan with everyone by doing a fire drill every few months. WARNING Do not enter a building where sirens are sounding Guidelines •Understand how to use your fire system. •Know the normal state of doors and windows: open, closed, or locked. •Escape fast! (Do not stop to pack.) •Use a different escape route if closed doors feel hot to the touch. •Crawl and hold your breath as much as possible to help reduce smoke inhalation during your escape. •Meet at a designated outdoor location. •Emphasize that no one should return to the premises if there is a fire. •Notify the fire department from a phone in another building. Your Floor Plan When establishing your escape routes, consider the following guidelines: •Have a drawing for each building level. •Show all exits (two exits per room are recommended). •Show the location of stairwells and fire escapes. •Show the location of all components of the fire system. •Show the locations of all fire extinguishers, hoses, ladders, etc. WARNING Smoke detectors CANNOT provide warnings for fires resulting from explosions, smoking in bed or other furniture, ignition of flammable liquids, vapors and gases, children playing with matches or lighters. Electrical Specifications Model 2-Wire 4-Wire Min.Volt. Max.Volt. Max. Ripple Typ.Avg.Stby. Typ. Alarm Cur. Typ.Avg. Pol. Alarm Relay Other Relay (PK to PK) Cur. (12-24V) (12-24V) Rev.Cur. Contacts Contacts (V) (uA) (mA) (mA) (A) (A) 429AT * 6.5 2010%70*see S09A --- 429C * 8.5 3310%70 *see S10A --- 429CT * 8.5 3310%70*see S10A --- 429CRT * 8.5 3310%70 *see S11A --2 429CST * 8.5 3310%70 *see S11A 10-- 449C * 8.5 3310%70 15 -0.5- 449CT * 8.5 3310%70 15 -0.5- 449CRT * 8.5 3310%70 31 -0.5- 449AT * 5.1 2710%70 15 -0.5- 449CST * 8.5 3310%70 40 100.5- 449CSRT * 8.5 3310%70 51 100.52 449CSRH ** * 8.5 3310%70 51 100.52 449CSTE * 8.5 3310%23mA 51 330.52 449CTE * 8.5 3310%23mA 31 230.52 Power Supervision Units ModelMin.Volt.Max. Volt.Typ. Avg. Stby.Cur.(uA)Relay Contacts (A) 204-6V (UL Listed) 5.1 1533mA @ 6VDC0.5 204-12/24V (UL Listed) 8.5 3314mA @ 12VDC, 28mA @ 24VDC0.5 Accessories SM-200 Smoke! in a can® canned smoke for functional testing of smoke detectors SM-EXT1 Smoke! in a can® extension accessory 211Replacement optical blocks (set of 10) 241Terminal block for 4-wire smoke detectors 449CTE, 449CSTE, 449AT, 449C, 449CT,449CST * 429 models draw up to a maximum of 60mA current if not limited by panel. ** 449CSRH model is a smoke alarm with isolated heat detector. Certain items in the installation instructions are protected under one or more of the following patents: 5,546,074; 5,798,701; 5,821,666; 6,756,906 Specifications Operating temperature......................32°F to 100°F (0°C to 38°C) Operating humidity range.......................0 to 95% non-condensing Sounder specifications............................................85dB at 10 feet Field wiring size............................................................14-24 AWG Self-diagnostic indication ..................typically 27 hours after reset (do not connect power supply that resets every 24 hours) Heat detector..................fixed temp 135°F, 50 foot (15m) spacing rate-of-rise 15°F/min > 105°F (8°C/min > 41°C) Auxiliary relay contacts........2A @ 28VDC or 120VAC (resistive) Alarm contacts..................................500mA @ 36VDC (resistive) Dimensions .................6.1” (15.5cm) diameter x 1.9” (4.7cm) deep Weight.....................................................................8.8 oz. (0.25kg) Color .......................................................................................white Wire Type Model Designator Power Designator Number DescriptionDesignator ListingDesignator Power 2 Two-wire only 9 UL A 6/12 VDC 4 Four-wire only C 12/24 VDC Product Selection Guide 449CSRT Series Designator Model Designator Wire Type Power Designator Features Features DesignatorFeatureDescription EEnd-of-Line Power Built-in end-of-line relay that also acts as a sensitivity status output. For four-wire only. Fail-safe Supervisory andrelay trips upon loss of power or if smoke detector is outside the approved sensitivity range for Sensitivity Status more than one day. End-of-line resistor is easily connected to terminal with no extra wiring, or Relay relay contacts can be connected to a separate trouble loop. HIsolated Fixed Temp.Isolated fixed 135°F (57°C) and rate-of-rise heat detector, independently trips the LED and alarm and Rate-of-Riserelay output. Smoke detector activates internal sounder (local alarm) and auxiliary relay, but does Heat Detectornot latch. Approved as both single station smoke alarm and system heat detector. RAuxiliary Relay Used to activate other devices such as elevator recall, door holders, etc. UL Listed for releasing services. SBuilt-in Sounder85db built-in sounder alarms when smoke is detected or when power wiring polarity is reversed. TIntegrated Fixed Temp.Integrated fixed 135°F (57°C) temp. and rate-of-rise heat detector offers double protection. and Rate-of-RiseEither heat detector or smoke detector can trip and latch LED and alarm relay outputs. Heat Detector GE Security 12345 SW Leveton Drive Tualatin, OR 97062 503-692-4052 USA & Canada: 800-547-2556 Tech Support: 800-648-7424 www.ge-security.com 14153D / September 2004 Before Installing This detector must be installed in compliance with the control panel installation manual and meet the requirements of NFPA 72, and/or the local authority having jurisdiction. Read this manual carefully before using the detec- tor. This manual should be left with the owner/user of this equipment. General Description The 5600 series mechanical heat detector is in- tended for use in property protection applications, or for non-life-safety installations where smoke de- tection is not practical or appropriate. WARNING For life-safety installations, smoke detectors must be used, in lieu of, or in addition to mechanical heat detectors. The 5600 series consists of both single- and dual- circuit heat detectors featuring fixed temperature thermal sensors or combination fixed temperature/ rate-of-rise sensors, with temperature ratings of 135ºF (57ºC) or 194ºF (90ºC). D500-46-00 1 I56-2175-003R INSTALLATION AND MAINTENANCE INSTRUCTIONS 3825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6495 www.systemsensor.com 5600 Series Mechanical Heat Detector Single Circuit: 5601P, 5602, 5603, 5604 Dual Circuit: 5621, 5622, 5623, 5624 Markings on the exterior of the detector indicate the specific activation method and temperature rating. All models are identified as either 135ºF/57ºC or 194ºF/90ºC. Models equipped with combination fixed tem-perature/rate-of-rise sensors are marked FX/ROR. Fixed temperature only models are marked FX. Non-Resettable Fixed Temperature Sensor The fixed temperature element reacts to heat by re- sponding to a specific temperature setting (135ºF or 194ºF). The detection method is based on the spring action of a metal contact, held to the metal chamber by a fusible alloy. When the temperature reaches the alloy’s melting point, the metal contact will depress the diaphragm, causing the electrical contact to close the circuit. The circular external heat collector is released from the detector to visu- ally indicate that the detector has been activated. NOTE: 5600 series Fixed Temperature models (5603, 5604, 5623, and 5624) are non-resettable, and can- not be tested. Specifications: Operating Voltage/Contact Ratings (Resistive): 6 – 125 VAC / 3A 6 – 28 VDC / 1A 125 VDC / 0.3A 250 VDC / 0.1A Maximum Installation Temperature: Models 5601P, 5603, 5621, and 5623: 100°F (38°C) Models 5602, 5604, 5622, and 5624: 150°F (65.6°C) Alarm Temperature: Models 5601P, 5603, 5621, and 5623: 135°F (57°C) Models 5602, 5604, 5622, and 5624: 194°F (90°C) Rate-of-Rise Threshold: 15°F (8.3°C) per minute (models 5601P, 5602, 5621, and 5622 only) Operating Humidity Range: 5 to 95% RH non-condensing Input Terminals: 14 – 22 AWG Back Box Mounting: 31⁄2˝ octagonal 4˝ octagonal Single gang 4˝ square with a square to round plaster ring Dimensions with mounting bracket: Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Weight: 6 oz. (170 grams) CAUTION To prevent the activation of the fixed temperature element, the shipping and storage temperature must not exceed 122°F (50°C). I5 6 - 2 1 7 5 - 0 0 3 R Self-Restoring Rate-of-Rise (ROR) Sensor The rate-of-rise element responds to a rapid rise of temperature, approximately 15ºF (8.3ºC) per min- ute. As the temperature rises, the air within the sealed chamber expands. Should the chamber air expand faster than it can escape through the cali- brated vent, the diaphragm is depressed, and the electrical contact closes the circuit. NOTE: Only the ROR element of 5600 series com- bination fixed temperature/ROR models (5601P, 5602, 5621, and 5622) are self-restoring, and may be tested using a hair dryer or heat gun. When testing the ROR element, to prevent the activation of the fixed temperature element, the heat source must not exceed the fixed temperature rating of the detector. Mounting Bracket All 5600 series detectors are equipped with a mount- ing bracket that includes mounting slots to accom- modate single-gang, 31⁄2˝ octagonal, and 4˝ octagonal electrical boxes, as well as 4˝ square boxes equipped with a plaster ring (Figure 1). The mounting bracket is reversible to accommodate flush-mount and sur- face–mount installations (Figure 2). Wiring Installation GuidelinesAll wiring must be installed in compliance with the National Electrical Code, applicable state and local codes, and any special requirements of the local Authority Having Jurisdiction. Proper wire gauges should be used. The conductors used to connect heat detectors to the alarm control panel and ac-cessory devices should be color-coded to reduce the D500-46-00 2 I56-2175-003R Heat Detector Type RTI Classification Fixed 135°F RTI: SPECIAL RoR and Fixed 135°F RTI: ULTRA FAST and SPECIAL (Respectively) Fixed 194°F RTI: SPECIAL RoR and Fixed 194°F RTI:ULTRA FAST and SPECIAL (Respectively) FM Classification RTI ratings are for installations which must comply with FM 3210. Table 1. 5600 Series Mechanical Heat Detectors Model No.Circuit Temperature Rating Thermal Sensor UL Maximum Spacing (10-foot ceiling) 5601P Single 135ºF (57ºC)Fixed Temperature/Rate of Rise 50-feet x 50-feet 5602 Single 194ºF (90ºC)Fixed Temperature/Rate of Rise 50-feet x 50-feet 5603 Single 135ºF (57ºC)Fixed Temperature 25-feet x 25-feet 5604 Single 194ºF (90ºC)Fixed Temperature 25-feet x 25-feet 5621 Dual 135ºF (57ºC)Fixed Temperature/Rate of Rise 50-feet x 50-feet 5622 Dual 194ºF (90ºC)Fixed Temperature/Rate of Rise 50-feet x 50-feet 5623 Dual 135ºF (57ºC)Fixed Temperature 25-feet x 25-feet 5624 Dual 194ºF (90ºC)Fixed Temperature 25-feet x 25-feet NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. A= 31⁄2˝ Octagonal boxB= 4˝ Octagonal box C= Single gang box and 4˝ square with plaster ring D= Directly to Wall/Ceiling Figure 1. Bracket Mounting Locations: S0113-00 S0114-00 S0115-00 Surface–mount Flush–mount Figure 2. Reversible Mounting Bracket: D500-46-00 3 I56-2175-003R likelihood of wiring errors. Improper connections can prevent a system from responding properly in the event of a fire. The non-polarized screw terminals on the back of the detector will accept 14–22 AWG wire. For best system performance, all wiring should be installed in separate grounded conduit; do not mix fire alarm system wiring in the same conduit as any other electrical wiring. Twisted pair may be used to pro- vide additional protection against extraneous elec- trical interference. Wire connections are made by stripping approxi- mately 1⁄4˝ of the insulation from the end of the feed wire, inserting it into the proper base terminal, and tightening the screw to secure the wire in place. + – EOL OR Control Panel Auxiliary Device Auxiliary Device Auxiliary Device Auxiliary Device Auxiliary Device Control Panel + – OR EOL Figure 3. Wiring Diagram – Single Circuit Models: Figure 4. Wiring Diagram – Dual Circuit Models: Installation Remove power from the alarm control unit or initi- ating device circuits before installing detectors. 1. Detach the detector from the mounting bracket by rotating the detector 1⁄4 turn counter-clockwise. 2. Orient the mounting bracket properly for either a flush- or surface-mount installation (Figure 2). 3. Select the pair of mounting holes suitable for the junction box, (Figure 1) and secure the bracket to the box. 4. Connect the wires to the detector per Figure 3 or Figure 4, as applicable. 5. Place the detector onto the mounting bracket by rotating clockwise. The detector will lock into place with a “click”. 6. After all detectors have been installed, apply power to the alarm control unit. 7. Test each detector as described in Testing. 8. Reset all the detectors at the alarm control unit. 9. Notify the proper authorities that the system is in operation. S0239-00 S0240-00 D500-46-00 4 I56-2175-003R ©2009 System Sensor Please refer to insert for the Limitations of Fire Alarm Systems System Sensor warrants its enclosed product to be free from defects in materials and workmanship under normal use and service for a period of three years from date of manufacture. System Sensor makes no other express warranty for the enclosed product. No agent, representative, dealer, or employee of the Company has the authority to increase or alter the obligations or limitations of this Warranty. The Company’s obligation of this Warranty shall be limited to the replacement of any part of the product which is found to be defec-tive in materials or workmanship under normal use and service during the three year period commencing with the date of manufacture. After phoning System Sensor’s toll free number 800-SENSOR2 (736-7672) for a Return Authorization number, send defective units postage prepaid to: System Sensor, Returns FCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in ac- cordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. – Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. – Consult the dealer or an experienced radio/TV technician for help. Department, RA #__________, 3825 Ohio Avenue, St. Charles, IL 60174. Please include a note describing the malfunction and suspected cause of failure. The Company shall not be obligated to replace units which are found to be defective because of damage, unrea-sonable use, modifications, or alterations occurring after the date of manufacture. In no case shall the Company be liable for any consequential or incidental damages for breach of this or any other Warranty, ex-pressed or implied whatsoever, even if the loss or dam-age is caused by the Company’s negligence or fault. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Three-Year Limited Warranty Testing/Maintenance The rate-of-rise mechanism may be subject to re- duced sensitivity over time. Annual testing of the rate-of-rise operation is therefore recommended. Before testing, notify the proper authorities that maintenance is being performed and the system will be temporarily out of service. Disable the zone or system undergoing maintenance to prevent any un- wanted alarms. Only the ROR element of 5600 series combination fixed temperature/ROR models (5601P, 5602, 5621, and 5622) are self-restoring, and may be tested us-ing a hair dryer or heat gun. WARNING When testing the ROR element, to prevent the ac- tivation of the fixed temperature element, the heat source must not exceed the fixed temperature rating of the detector. WARNING 5600 series fixed temperature models (5603, 5604, 5623, and 5624) are non-resettable, and cannot be tested. CAUTION When using the RRS-MOD with model 2WTA-B, do not mix the 2WTA-B with other model smoke de- tectors and dry contact closure devices, including mechanical heat detectors, manual pull stations and waterflow switches. Such mixing can cause a direct short on the auxiliary power terminals, damaging the control panel’s internal circuitry and/or damage devices connected to the initiating device circuit. Agency Listings Mini-Horns The SpectrAlert® Advance series of mini-horn sounders are designed to simplify installations to provide primary and secondary signaling for fire and security applications. Features • 12 and 24V operation • High and low volume settings • Temporal and non-temporal tones • Mounts to single gang back box • Compatible with MDL sync module • Mechanically and electrically compatible with PA400 series Mini-Alert™ sounders • Listing for ceiling or wall mounting The MHR and MHW mini-horns operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications, where a smaller notification device is desired. The mini-horns offer high and low volume settings, and temporal or non-temporal tones. The horns can be mounted to single gang back boxes for aesthetically sensitive applications. Synchronization is also provided when using the MDL module. The MHR and MHW mini-horns can operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supply. They are listed to Underwriter’s Laboratories Standard UL 464 for fire protective signaling systems. S4011 3028007 CS1099 7135-1653:196 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2012 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS01500 • 3/12 Ordering Information Part No.Description MHR Mini-Horn, Red MHW Mini-Horn, White SpectrAlert® Advance Mini-Horn Specifications Architectural/Engineering Specifications Mini-horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a deep single gang back box. Mini-horn shall be listed to Underwriter’s Laboratories Standard UL464 for fire protective signaling systems. Mini-horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. When used with the Sync•Circuit™ Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Physical Specifications Dimensions 4.6˝L × 2.9˝W × .45˝D Weight 2.67 oz. Operating Temperature Range 32°F to 120°F (0°C to 49°C) Mounting Surface: deep single-gang back box (23/4˝ deep) Flush: Standard 4˝ × 4˝ back box with single gang mud ring, which allows sufficient clearance for conduit entrance. Electrical Specifications Input Terminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8–33 Operating Voltage with MDL 9–33 UL Sound Output and Current Draw Data Sounder Output (dBA) Switch Setting Pattern Output Level 8–17.5 VDC 8–17.5 VFWR Nominal 12 VDC Nominal 12 VFWR 16–33 VDC 16–33 VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non- temporal High 72 71 75 74 80 79 4 Non- temporal Low 70 69 73 72 78 77 Sounder Current Draw (mA RMS) Switch Position Sound Pattern Volume 8–17.5 Volts 16–33 Volts DC FWR DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 25 4 Non-temporal Low 17 13 21 19 Agency Listings CO1224T and CO1224TR Carbon Monoxide Detectors with RealTest® Technology The System Sensor CO1224T and CO1224TR (round) Carbon Monoxide (CO) Detectors use a highly accurate and reliable electrochemical sensing cell to provide early warning of dangerous CO levels. Features • RealTest® enables a functional test using canned CO • Full compliance with UL 2075 • A code-required trouble relay • Wiring supervision with SEMS terminals • A six-year end-of-life timer • 12/24 VDC • A low current draw of 20 mA in standby and 40 mA in alarm • Versatile mounting for wall and ceiling • Accurate and reliable electrochemical sensing technology • Optional CO-PLATE CO Detector Replacement Plate to upgrade previously installed competitor detectors to the CO1224T With RealTest® technology, the CO gas sensing cell used in the CO1224T and CO1224TR CO detectors can be tested using a CO gas agent, fully meeting the requirements of NFPA 720: 2009. Simply put the detector into RealTest mode, spray a small amount of CO into the detector per the installation instructions, and within seconds the detector will alarm, indicating successful gas entry. (See the reverse page or the user manual for complete instructions.) When dangerous amounts of CO are detected, the CO1224T and CO1224TR detectors alert residents by sounding and flashing a temp 4 signal alarm. With 24/7 central station monitoring, residents are guaranteed protection whether they are away from home, sleeping, or already suffering from the effects of CO. The CO1224T and CO1224TR are designed for system operation. These detectors are fully listed to UL 2075 and offer a code- required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station. The CO1224T and CO1224TR also use SEMS-type terminal Philips head screws for quicker and more positive wiring connections and code-required wiring supervision. With a low current draw, these detectors enable more devices to be connected to the panel, limiting the need to purchase extra power supplies or more expensive panels. As 12/24 VDC detectors, the CO1224T and CO1224TR will operate on most industry security and fire alarm control panels. E307195 E304075 5276-1653:0194 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2012 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.SCDS00100 • 4/12 Ordering Information Part No.Description CO1224T 12/24 volt, 4-wire system-monitored carbon monoxide detector with RealTest® Technology CO1224TR 12/24 volt, 4-wire system-monitored round carbon monoxide detector with RealTest® Technology CO-PLATE CO detector replacement plate to cover the footprint of previously installed competitive detectors as necessary CO1224T and CO1224TR Carbon Monoxide Detector Specifications Architectural/Engineering Specifications Carbon monoxide (CO) detector shall be a system-connected System Sensor model number CO1224T or CO1224TR listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors. The detector shall be equipped with a sounder and a trouble relay. The detector’s base shall be able to mount to a single-gang electrical box or direct (surface) mount to the wall or ceiling. Wiring connections shall be made by means of SEMS screws. The detector shall provide dual-color LED indication that blinks to indicate normal standby, alarm, or end-of-life. When the sensor supervision is in a trouble condition, the detector shall send a trouble signal to the panel. When the detector gives a trouble or end-of-life signal, the detector shall be replaced. The detector shall provide a means to test CO gas entry into the CO sensing cell. The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. The detector shall perform in the detection of CO up to 12,000 feet above sea level and alarm within the time specified by ANSI/UL 2034 for CO concentrations of 70, 150 and 400 parts per million (ppm), as verified by a Nationally Recognized Test Laboratory. Electrical Specifications Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA (75 mA test) Alarm Contact Ratings 0.5 A @ 30 VDC Trouble Contact Ratings 0.5 A @ 30 VDC Physical Specifications Size: CO1224T Length: 5.1 in, Width: 3.3 in, Height: 1.3 in CO1224TR Diameter: 6 in, Height: 1.3 in Approximate Weight CO1224T: 7 oz ; CO1224TR: 11 oz Operating Temperature Range 32°F to 104° F (0°C to 40° C) Operating Humidity Range 22 to 90% RH Input Terminals 14 to 22 AWG Mounting Single-gang back box; surface mount to wall or ceiling Operation Modes Operation Mode Green LED Red LED Sounder Normal (standby)Blink 1 per minute —— Alarm —Blink in temp 4 pattern Sound in temp 4 pattern RealTest® Feature: The System Sensor CO1224T and CO1224TR Carbon Monoxide Detectors with RealTest enable evaluation of the functionality of the CO sensing cell using a canned CO test agent. Hush Feature: Pushing the Test/Hush button will silence the sounder for 5 minutes (except in RealTest mode). Trouble Feature: When the detector is in a trouble condition, it will send a trouble signal to the panel. End-of-Life Timer: After the detector’s internal sensor has reached the end of its life, a trouble signal will be sent to the panel to indicate it is time to replace the detector. An electrochemical CO detector lifespan is about six years. The detector must be replaced by the date marked on the inside of the product. CO-PLATE: System Sensor also offers the CO-PLATE CO Detector Replacement Plate to cover the footprint (when necessary) of previously installed competitive carbon monoxide detectors that require replacement. 3. Push and hold the Test/Hush button for two seconds to enter RealTest mode. The green LED will flash once every second to indicate RealTest mode has started. Spray canned CO agent into the detector. CO-PLATE Verify CO sensing at the control panel. The detector will automatically exit RealTest alarm mode after about 20-60 seconds. NOTE: Check with local codes and the AHJ to determine if a functional gas test is desired for an installation. 1.2. K5894V5 6/04 Rev A AAAAAAAADDDDDDDDEEEEEEEEMMMMMMMMCCCCCCCCOOOOOOOO VVVVVVVVIIIIIIIISSSSSSSSTTTTTTTTAAAAAAAA SSSSSSSSEEEEEEEERRRRRRRRIIIIIIIIEEEEEEEESSSSSSSS VVVVVVVVIIIIIIIISSSSSSSSTTTTTTTTAAAAAAAA--------111111112222222288888888BBBBBBBBPPPPPPPP////////VVVVVVVVIIIIIIIISSSSSSSSTTTTTTTTAAAAAAAA--------222222225555555500000000BBBBBBBBPPPPPPPP//////// VVVVVVVVIIIIIIIISSSSSSSSTTTTTTTTAAAAAAAA--------111111112222222288888888SSSSSSSSIIIIIIIIAAAAAAAA Commercial BurglaryCommercial BurglaryCommercial BurglaryCommercial Burglary Partitioned Security SystemPartitioned Security SystemPartitioned Security SystemPartitioned Security System With SchedulingWith SchedulingWith SchedulingWith Scheduling Installation and Setup Guide . iii Table of Contents •••••••••••••••••••••••••••••••••••••••••••••••• •• List of Figures...................................................................................................................................................vi Conventions Used in This Manual..................................................................................................................vii SECTION 1: General Description...................................................................................................................1-1 About the VISTA-128BP/VISTA-250BP.......................................................................................................................1-1 Features....................................................................................................................................................................1-2 SECTION 2: Partitioning and Panel Linking..................................................................................................2-1 Theory of Partitioning .................................................................................................................................................2-1 Setting-Up a Partitioned System.................................................................................................................................2-1 Common Lobby Logic.................................................................................................................................................2-1 Master Keypad Setup and Operation..........................................................................................................................2-3 Panel Linking..............................................................................................................................................................2-4 SECTION 3: Installing the Control.................................................................................................................3-1 Mounting the Control Cabinet .....................................................................................................................................3-1 Installing the Cabinet Lock..........................................................................................................................................3-1 Grade A Mercantile Premises Listing Guidelines.........................................................................................................3-1 Grade A Mercantile Safe and Vault Listing Guidelines.................................................................................................3-2 Installing the Control's Circuit Board...........................................................................................................................3-2 Installing the Keypads ................................................................................................................................................3-4 Installing External Sounders.......................................................................................................................................3-4 Telephone Line Connections ......................................................................................................................................3-5 Wiring Burglary, Panic and Smoke Detector Devices to Zones 1-9..............................................................................3-5 Installing RPM Devices.............................................................................................................................................3-11 Wireless Zone Expansion .........................................................................................................................................3-13 Installing Output Devices..........................................................................................................................................3-17 Installing the Ground Start Module............................................................................................................................3-18 Installing a Remote Keyswitch..................................................................................................................................3-16 Smoke Detector Reset.............................................................................................................................................3-20 Remote Keypad Sounder .........................................................................................................................................3-20 Installing the VA8200 Panel Link Module ..................................................................................................................3-20 Long Range Radio Connected to the J7 Triggers......................................................................................................3-22 Long Range Radio Connected to the ECP ................................................................................................................3-22 Installing the Alpha Pager Module.............................................................................................................................3-23 Access Control Using VistaKey.................................................................................................................................3-25 Access Control Using the PassPoint Access Control System....................................................................................3-26 Installing a 4100SM..................................................................................................................................................3-27 Installing the 4285/4286 VIP Module.........................................................................................................................3-28 Installing the Audio Alarm Verification Module...........................................................................................................3-30 Installing TeleSmart..................................................................................................................................................3-31 Connecting the Transformer.....................................................................................................................................3-35 Panel Earth Ground Connections .............................................................................................................................3-36 Determining the Control’s Power Supply Load ..........................................................................................................3-36 Determining the Size of the Standby Battery.............................................................................................................3-37 SECTION 4: Programming..............................................................................................................................4-1 Program Modes .........................................................................................................................................................4-1 Entering and Exiting Programming Mode....................................................................................................................4-1 Data Field Programming Mode...................................................................................................................................4-1 #93 Menu Mode Programming ...................................................................................................................................4-2 Zone Number Designations ........................................................................................................................................4-4 Zone Response Type Definitions ................................................................................................................................4-6 Zone Input Type Definitions........................................................................................................................................4-7 Programming for Panel Linking...................................................................................................................................4-8 Programming for the Alpha Pager Module ..................................................................................................................4-8 Programming for 4100SM ..........................................................................................................................................4-9 Table of Contents iv Programming for Access Control................................................................................................................................4-9 Programming for ECP Long Range Radio.................................................................................................................4-10 Programming for TeleSmart.....................................................................................................................................4-10 SECTION 5: Data Field Descriptions .............................................................................................................5-1 About Data Field Programming...................................................................................................................................5-1 Programming Data Fields...........................................................................................................................................5-1 SECTION 6: Scheduling Options...................................................................................................................6-1 Time Window Definitions ............................................................................................................................................6-2 Open/Close Schedules Definitions..............................................................................................................................6-2 Scheduling Menu Mode..............................................................................................................................................6-4 Time Windows............................................................................................................................................................6-5 Daily Open/Close Schedules ......................................................................................................................................6-2 Holiday Schedules......................................................................................................................................................6-1 Time-Driven Events....................................................................................................................................................6-1 Limitation of Access Schedules ..................................................................................................................................6-1 Temporary Schedules ..............................................................................................................................................6-12 User Scheduling Menu Mode....................................................................................................................................6-14 SECTION 7: Downloading Primer..................................................................................................................7-1 General Information ...................................................................................................................................................7-1 Unattended Download ................................................................................................................................................7-1 Getting On-Line with a Control Panel..........................................................................................................................7-3 Scheduled Download................................................................................................................................................7-16 Direct-Wire Downloading..........................................................................................................................................7-16 Telco Handoff.............................................................................................................................................................7-2 SECTION 8: Setting the Real-Time Clock......................................................................................................8-1 General Information ...................................................................................................................................................8-1 Setting the Time and Date..........................................................................................................................................8-1 SECTION 9: User Access Codes ....................................................................................................................9-1 General Information ...................................................................................................................................................9-1 User Codes & Levels of Authority ...............................................................................................................................9-1 Multiple Partition Access.............................................................................................................................................9-2 Adding a Master, Manager, or Operator Code ............................................................................................................9-2 Changing a Master, Manager, or Operator Code ........................................................................................................9-4 Adding an RF Key to an Existing User........................................................................................................................9-4 Deleting a Master, Manager, or Operator Code ..........................................................................................................9-4 Exiting the User Edit Mode.........................................................................................................................................9-5 SECTION 10: Testing the System................................................................................................................10-1 Battery Test.............................................................................................................................................................10-1 Dialer Test...............................................................................................................................................................10-1 Burglary Walk-Test (Code + [5] TEST)......................................................................................................................10-1 Armed Burglary System Test....................................................................................................................................10-1 Testing Wireless Transmitters..................................................................................................................................10-2 Trouble Conditions...................................................................................................................................................10-2 To the Installer.........................................................................................................................................................10-2 APPENDIX A: Regulatory Agency Statements.............................................................................................A-1 UL Installation Requirements......................................................................................................................................A-1 UL609 Grade A Local Mercantile Premises/Local Mercantile Safe & Vault ..................................................................A-1 UL365 Police Station Connected Burglar Alarm ..........................................................................................................A-1 UL611/UL1610 Central Station Burglary Alarm ...........................................................................................................A-2 California State Fire Marshal (CSFM) and UL Residential Fire Battery Backup Requirements .....................................A-2 APPENDIX B: Summary of System Commands...........................................................................................B-1 APPENDIX C: Specifications.........................................................................................................................C-1 APPENDIX D: Contact ID and Pager Event Codes.......................................................................................D-1 TABLE OF CONTACT ID EVENT CODES..................................................................................................................D-1 Event Log and Pager Alpha Descriptors .....................................................................................................................D-1 Index.........................................................................................................................................................Index-1 THE LIMITATIONS OF THIS ALARM SYSTEM Table of Contents v ADEMCO LIMITED WARRANTY vi List of Figures •••••••••••••••••••••••••••••••••••••••••••••••• •• Figure 3-1: Installing the Lock...........................................................................................................................................3-1 Figure 3-2: Cabinet Attack Resistance Considerations......................................................................................................3-2 Figure 3-3: Mounting the PC Board ..................................................................................................................................3-4 Figure 3-4: Keypad Connections to Control Panel.............................................................................................................3-4 Figure 3-5: Using A Supplementary Power Supply............................................................................................................3-4 Figure 3-6: Wiring Polarized Fire Devices.........................................................................................................................3-5 Figure 3-7: Wiring Nonpolarized Burglary Devices ............................................................................................................3-5 Figure 3-8: Telephone Line Connections ..........................................................................................................................3-5 Figure 3-9: Wiring Connections for Zones 1-9...................................................................................................................3-6 Figure 3-10: 2-Wire Smoke Detector on Zone 1................................................................................................................3-8 Figure 3-11: 4-Wire Smoke Detectors...............................................................................................................................3-8 Figure 3-12a: Wiring a 333PRM to the Control..................................................................................................................3-2 Figure 3-12b: Wiring a 333PRM using a 4204...................................................................................................................3-2 Figure 3-12c: Wiring a 333PRM using a 4204 and a Power Supply ...................................................................................3-9 Figure 3-13: Wiring Latching Glassbreaks to Zone 8..........................................................................................................3-9 Figure 3-14: Wiring a Normally Closed Loop for Tamper Supervision..............................................................................3-11 Figure 3-15: Wiring a Normally Open Loop for Tamper Supervision................................................................................3-11 Figure 3-16: Polling Loop Connections to the VISTA-128BP/VISTA-250BP.....................................................................3-13 Figure 3-17: Polling Loop Connections Using One 4297 Extender Module ......................................................................3-13 Figure 3-18: Polling Loop Connections Using Multiple Extender Modules........................................................................3-13 Figure 3-19: Installing the 5881ENHC with Tamper Protection .........................................................................................3-14 Figure 3-20: 5881 RF Receiver (cover removed)............................................................................................................3-15 Figure 3-21: 4204 Relay Module.....................................................................................................................................3-17 Figure 3-22: 4204CF Relay Module ................................................................................................................................3-17 Figure 3-23: Wiring the FSA Module...............................................................................................................................3-18 Figure 3-24: Ground Start Module Connections..............................................................................................................3-16 Figure 3-25: Remote Keyswitch Wiring...........................................................................................................................3-20 Figure 3-26: Remote Keypad Sounder Wiring.................................................................................................................3-20 Figure 3-27: Panel Linking Block Diagram ......................................................................................................................3-20 Figure 3-28: VA8200 Panel Link Module Wiring..............................................................................................................3-20 Figure 3-29: Wiring Long Range Radio to Keypad Terminals ..........................................................................................3-23 Figure 3-30: Wiring the Alpha Pager Module...................................................................................................................3-25 Figure 3-31: Wiring the VistaKey.....................................................................................................................................3-26 Figure 3-32: Wiring the VISTA Gateway Module.............................................................................................................3-27 Figure 3-33: 4100SM Using a Serial Printer.....................................................................................................................3-27 Figure 3-34: 4100SM Using Home Automation ...............................................................................................................3-28 Figure 3-35: VIP Module Connections ............................................................................................................................3-29 Figure 3-36: UVS Connections to the Control Panel........................................................................................................3-31 Figure 3-37: TeleSmart Phone Connections ...................................................................................................................3-33 Figure 3-38: TeleSmart Speaker Connection ...................................................................................................................3-33 Figure 3-39: Keypad Connections....................................................................................................................................3-34 Figure 3-40: RTC and Ground Connections.....................................................................................................................3-34 Figure 3-41: TeleSmart to Control Connections ...............................................................................................................3-34 Figure 3-42: 1361 Transformer and Battery Connections................................................................................................3-35 Figure 3-43: 1361X10 Transformer Connections.............................................................................................................3-35 Figure 7-1: Direct-Wire Downloading Connections ............................................................................................................7-2 vii Conventions Used in This Manual •••••••••••••••••••••••••••••••••••••••••••••••• •• Before you begin using this manual, it is important that you understand the meaning of the following symbols (icons). UL These notes include specific information that must be followed if you are installing this system for a UL Listed application. These notes include information that you should be aware of before continuing with the installation, and that, if not observed, could result in operational difficulties. This symbol indicates a critical note that could seriously affect the operation of the system, or could cause damage to the system. Please read each warning carefully. This symbol also denotes warnings about physical harm to the user. ZONE PROG? 1 = YES 0 = NO 0 Many system options are programmed in an interactive mode by responding to alpha keypad display prompts. These prompts are shown in a single-line box. ✴00 Additional system options are programmed via data fields, which are indicated by a “star” (✴) followed by the data field number. PRODUCT MODEL NUMBERS: Unless noted otherwise, references to specific model numbers represent ADEMCO products. 1-1 SECTION 1 General Description •••••••••••••••••••••••••••••••••••••••••••••••• •• About the VISTA-128BP/VISTA-250BP All references to the VISTA-128BP also pertain to the VISTA-128SIA. The differences between the two panels are outlined in the supplement accompanying the VISTA-128SIA. The supplement must be referred to when programming the VISTA-128SIA. The VISTA-128BP/VISTA-250BP is an 8-partition, UL Listed control panel with the following features: • Supports hardwired, polling loop, and wireless zones • Supervision of bells, keypads, RF receivers, and output devices • Scheduling capabilities (allows certain operations to be automated) • The capability to link up to 8 control panels using Panel Linking Modules The VISTA-128BP/VISTA-250BP can interface with the following devices: • TeleSmart (See the TeleSmart instructions for operating procedures) • An alpha numeric paging device (VA8201) • Symphony (AUI) • Panel Link Module (VA8200) • Voice Keypad (6160V) • An ECP Long Range Radio that can send Contact ID messages • An access control system by using either the ADEMCO PassPoint system (via the VISTA Gateway Module) or a VistaKey module (via the polling loop) UL The access control function is not Listed for use with the VISTA-128BP/VISTA-250BP Control Panel in a UL installation. The system supports either the VistaKey or the VISTA Gateway Module, not both. NOTE: All references in this manual for number of zones, number of user codes, number of access cards, and the event log capacity, use the VISTA-250BP’s features. The following table lists the differences between the VISTA-128BP and the VISTA-250BP control panels. All other features are identical, except for the Remote Keypad Sounder (field 1✴46 option 2), which is available only in the VISTA128BP. Feature VISTA-128BP VISTA-250BP Number of Zones 128 250 Number of User Codes 150 250 Number of Access Cards 250 500 Event Log Capacity 512 1000 VistaKey Modules 8 15 VISTA-128BP/VISTA-250BP Installation and Setup Guide 1-2 Features Hardwire and Optional Expansion Zones • Provides 9 hardwire zones. • Supports up to 16 2-wire smoke detectors on zone 1. • Automatically resets 4-wire smoke detectors using the J7 output when a code + off is entered. • Triggers the built-in sounders on other hardwired smoke detectors if one smoke detector annunciates an alarm. This feature requires a 4204 Relay Module and/or the 333PRM. • Provides tamper supervision on the hardwire zones. • Supports up to 50 2-wire latching glassbreak detectors on zone 8. • Supports up to 241 additional expansion zones (119 for the VISTA-128BP) using a built-in polling (multiplex) loop. • Supports up to 250 wireless zones (128 for the VISTA-128BP) (fewer if using hardwire and/or polling loop zones). UL The 5881ENHC RF Receiver and the 5869 Holdup Switch Transmitter are listed for UL Commercial Burglary applications. All other RF receivers and transmitters are not listed for UL Commercial Burglary applications. • Can program burglary zones as silent in the alarm condition (alarm output is silent and the keypad does not display or sound the alarm). • Provides three keypad panic keys: 1 + ✴ (A), ✴ + # (B), and 3 + # (C). Peripherals Devices • Supports up to 31 addressable devices, (keypads, RF receivers, relay modules, etc.). • Supervises devices (keypads, RF receivers, and relay modules) and individual relays (up to 32), as well as system zones (RF receivers and keypad panics). • Provides 96 outputs using 4204 and 4204CF Relay Modules, Fire System Annunciators (FSA-8, FSA-24), V-Plex Relay Modules and X-10 devices can activate outputs in response to system events (alarm condition), at a specific time of day, at random times, and manually using the #70 Relay Command Mode. • Supports the ADEMCO 4285/4286 VIP Module, which allows access to the system from either a remote location or on the premises UL The VIP Module is not Listed for use with the VISTA-128BP/VISTA-250BP Control Panel in a UL installation. • Supports the ADEMCO 4146 Keyswitch on any one of the system's 8 partitions. Arming/Disarming and Bypassing • Can arm the system with zones faulted (Vent Zone). These zones are automatically bypassed and can be programmed to automatically unbypass when the zone restores. • Can arm with entry/exit and interior type zones faulted (Arm w/Fault). These zones must be restored before the exit delay expires, otherwise an alarm is generated. UL • Vent zones cannot be used in UL installations. • You must disable the Force Arm option (used in conjunction with the Arm w/Fault option), in UL installations. • Provides global arming capability (ability to arm all partitions the user code has access to in one command). • Can Quick Exit an armed premises without having to disarm and then rearm the system. UL Quick Exit is not permitted for use with the VISTA-128BP/VISTA-250BP Control Panel in a UL installation. Section 1 - General Description 1-3 • Can be armed in one of three STAY modes or Instant modes, automatically bypassing specific burglary zones regardless of the zone response type. • Can automatically bypass specific zones if no one exits the premises after arming (Auto-STAY). Auto-STAY will not occur if the system is armed via an RF transmitter, VIP module, scheduling, access control, keyswitch, RS232 automation or downloading. • Can bypass a group of zones with one set of keystrokes. • Supports Exit Error Logic, whereby the system can tell the difference between a regular alarm and an alarm caused by leaving an entry/exit door open. If the system is not subsequently disarmed, faulted E/E zone(s) and/or interior zones are bypassed and the system arms. • Supports Recent Close report, which is designed to notify the central station that an alarm has occurred within 2 minutes after the exit delay has expired. Partitioning and Panel Linking • Can control 8 separate areas independently, each functioning as if it had its own separate control. • Provides a Common Lobby partition, which can be programmed to arm automatically when the last partition is armed, and to disarm when the first partition is disarmed. • Provides a Master partition (9), used for the purpose of viewing the status of all partitions at the same time. • Can display fire, burglary, panic and trouble conditions at all other partitions’ keypads (selectable option). • Can “link” together up to 8 control panels. This allows users to access and control from a keypad another control panel. Scheduling • Can automate system functions, such as arming, disarming, and activation of outputs (e.g., lights). • Provides access schedules (for limiting system access to users by time). • Provides an End User Output Programming Mode, allowing the user to control outputs. Access Control • Supports up to 15 VistaKey modules (15 access points) (VISTA-128BP supports 8 modules), which are used for access control. It is a single-door access control module. • Support up to 500 access cards. • Supports ADEMCO PassPoint system via one VISTA Gateway Module (VGM), for a fully integrated access control system. • Can store access control events in the event log. System Communication • Supports ADEMCO Contact ID; ADEMCO High Speed; ADEMCO Express; and 3+1, 4+1, and 4+2 ADEMCO and Sescoa/Radionics Low-Speed formats. The system is shipped defaulted for Contact ID communication. It is the only format capable of uniquely reporting all 250 zones, as well as openings and closings for all 250 users. This requires central stations to be equipped with the ADEMCO 685 receiver using software level 4.10 or higher to fully support all new VISTA-128BP/VISTA-250BP report codes. If you need to update your 685 receiver, contact your distributor. • Can send messages such as alarms, opens/closes, etc. to up to 8 paging services. • Provides two paging formats (alphanumeric – requires the VA8201 Alpha Pager Module; and numeric – sent directly by the control) • Supports Dynamic Signaling feature, which prevents redundant signals being sent to the central station when both the built-in dialer and Long Range Radio are used. • Provides an Audio Alarm Verification (AAV) option that permits voice dialog between an operator at the central station and a person at the premises. An AAV unit, such as ADEMCO UVS, is required. VISTA-128BP/VISTA-250BP Installation and Setup Guide 1-4 Downloading • Supports upload and download capability. • Can perform unattended downloading (no one at the downloading computer). • Provides an Installer Unattended Program Mode. This allows the installer to program the download phone number, subscriber number, and primary central station receiver phone number without entering the normal program mode. • Can periodically and automatically perform a scheduled download. UL Unattended and Scheduled Downloading are not UL Listed features. • Can download access control cardholder information. Event Log • Provides an event log (history log) that can store up to 1000 events. • Can print the event log on a parallel or serial printer using a VA8201 Alpha Pager Module. • Can view the event log on an alpha keypad or AUI. Additional Features • Provides up to 60 installer-defined, custom words that can be used for zone descriptors. • Provides 32 keypad macro commands (each macro is a series of keypad commands of up to 32 keystrokes) using the A, B, C, and D keys by partition. • Provides cross-zone capability, which helps prevent false alarms by preventing a zone from going into alarm unless its cross-zone is also faulted within a 5-minute period. • Contains a built-in User’s Manual, which provides the end user with a brief explanation of the function of a key when the user presses any of the function keys on the keypad for 5 seconds. • Provides trigger outputs, which may interface with Long Range Radio equipment or other devices such as keyswitch LEDs, printer, or pager. • Provides an RS232 input for serial data. This is useful for interfacing the system with Automation software. Automation software cannot be used if a serial printer is used on the system. At least one 2-line alpha keypad (6139/6160) must be connected to the system for programming (if you are using keypad programming), and must remain connected to the system in order to allow the primary user to program additional user codes into the system at a later time. 2-1 SECTION 2 Partitioning and Panel Linking •••••••••••••••••••••••••••••••••••••••••••••••• •• Theory of Partitioning This system provides the ability to arm and disarm up to 8 different areas, as if each had its own control. These areas are called partitions. A Partitioned system allows the user to disarm certain areas while leaving other areas armed, or to limit access to certain areas to specific individuals. Each system user can be assigned to operate any or all partitions, and can be given a different authority level in each. Before anything can be assigned to those partitions, you must first determine how many partitions (1-8) are required. Following are some facts you need to know about partitioning. Keypads Each keypad must be given a unique "address" and be assigned to one partition. It can also be assigned to Partition 9 if Master keypad operation is desired. (See “Master Keypad Setup and Operation” later in this section.) Zones Each zone must be assigned to one partition. The zones assigned to a partition will be displayed on that partition's keypad(s). Users Each user may be given access to one or more partitions. If a user is to operate more than one partition and would like to arm/disarm all or some of those partitions with a single command, the user must be enabled for Global Arming for those partitions (when entering user codes). A user with access to more than one partition (multiple access) can "log on" to one partition from another partition's keypad, provided that program field 2*18: Enable GOTO is enabled for each partition he/she wants to log on to from another. A partition can be selected as a "common lobby" partition, and other partitions can affect this partition by causing arming/disarming of this partition to be automated (see “Common Lobby Logic” later in this section). Setting-Up a Partitioned System The basic steps to setting up a partitioned system are described below. If you need more information on how to program the options, see SECTION 4: Programming. 1. Determine how many partitions the system will consist of (programmed in field 2*00). 2. Assign keypads to partitions (Device Programming in the #93 Menu Mode). 3. Assign zones to partitions (Zone Programming in the #93 Menu Mode). 4. Confirm zones are displayed at the keypad(s) assigned to those partitions. 5. Assign users to partitions. 6. Enable the GOTO feature (program field 2*18) for each partition a multiple-access user can log on to (alpha keypad only). 7. Program partition-specific fields (see the Data Field Descriptions section). Common Lobby Logic When an installation consists of a partition shared by users of other partitions in a building, that shared partition may be assigned as the "common lobby" partition for the system (program field 1*17). An example of this might be in a medical building where there are two doctors’ offices and a common entrance area (see example that follows explanation). The Common Lobby feature employs logic for automatic arming and disarming of the common lobby. Two programming fields determine the way the common lobby will react relative to the status of other partitions. They are: 1*18 Affects Lobby and 1*19 Arms Lobby. VISTA-128BP/VISTA-250BP Installation and Setup Guide 2-2 1*18 Affects Lobby (must be programmed by partition) Setting this field to 1 for a specific partition causes that partition to affect the operation of the common lobby as follows: a. When the first partition that affects the lobby is disarmed, the lobby is automatically disarmed. b. The common lobby cannot be armed unless every partition selected to affect the lobby is armed. 1*19 Arms Lobby (must be programmed by partition) Setting this field to 1 for a specific partition causes that partition to affect the operation of the common lobby as follows: a. The common lobby cannot be armed unless every partition selected to affect the lobby is armed. b. Arming a partition that is programmed to arm the lobby causes the system to automatically attempt to arm the lobby. If any faults exist in the lobby partition, or if another partition that affects the lobby is disarmed, the lobby cannot be armed, and the message "UNABLE TO ARM LOBBY PARTITION" is displayed. You cannot select a partition to "arm" the lobby unless it has first been selected to "affect" the lobby. Do not enable field 1*19 without enabling field 1*18. The following chart sums up how the common lobby partition will operate. 1*18 Affects Lobby 1*19 Arms Lobby Disarms when partition disarms? Attempts to arm when partition arms? Can be armed if other partitions disarmed? 0 0 NO NO YES 1 0 YES NO NO 1 1 YES YES NO 0 1 ---ENTRY NOT ALLOWED--- Example Here is an example of how the lobby would react in a typical setup. OFFICE 1OFFICE 2 MAIN ENTRANCE COMMON LOBBY V128BP-001-V0 User #1 has access to Office #1 and the Common Lobby. User #2 has access to Office #2 and the Common Lobby. Office #1 is set up to affect the Common Lobby, but not arm it. Office #2 is set up to affect and arm the Common Lobby. NOTE: In the tables below, the notations in parentheses ( ) indicate the current status of the other partition when the user takes action. Sequence #1: Office 1 Office 2 Lobby Action User #1: Disarms (Armed) Disarms User #2: (Disarmed) Disarms No Change User #1: Arms (Disarmed) No change User #2: (Armed) Arms Arms Sequence #2: Office 1 Office 2 Lobby Action User #2: (Armed) Disarms Disarms User #1: Disarms (Disarmed) (No change) User #2: (Disarmed) Arms No Change User #1: Arms (Armed) No Change Notice that in sequence #1, because Office #2 was the last to arm, the lobby also armed (Office #2 is programmed to affect and arm the lobby). In sequence #2, the lobby could not arm when Office #2 armed, because Office #1, which affects the lobby, was still disarmed. When Office #1 armed, the lobby still did not arm because Office #1 was not programmed to arm the lobby. User #1 would have to arm the lobby manually. Therefore, you would want to program a partition to Section 3 - Installing the Control 2-3 affect and arm the lobby if the users of that partition are expected to be the last to leave the building. How User Access Codes Affect the Common Lobby Codes with Global Arming If a code is given "global arming" when it is defined (see SECTION 9: User Access Codes), the keypad prompts the user to select the partitions they want to arm. Only the partitions the user has access to are displayed. This allows the user to choose the partitions to be armed or disarmed, and so eliminates the "automatic" operation of the lobby. Keep in mind, however, that if a user attempts to arm all, and another "affecting" partition is disarmed, the user cannot arm the lobby, and the message "UNABLE TO ARM LOBBY PARTITION" is displayed. Codes with Non-Global Arming If a user arms with a non-global code, the lobby partition operation is automatic, as described by fields 1*18 and 1*19. Other Methods of Arming/Disarming Common Lobby logic remains active when arming or disarming a partition that affects and/or arms the common lobby in one of the following manners: • Quick-Arm • Keyswitch • Wireless Button • Wireless Keypad Arming/Disarming Remotely If a user arms or disarms remotely (through Compass downloading software), the lobby does not automatically follow another partition that is programmed to arm or disarm the lobby. The lobby must be armed separately, after arming all affecting partitions first. Auto-Arming/Disarming If scheduling is used to automatically arm and/or disarm partitions, the common lobby partition does not automatically follow another partition that is programmed to arm or disarm the lobby. The lobby must be included as a partition to be armed/disarmed and must be scheduled as the last partition armed. If you are using auto-arming, make sure that the Auto-Arm Delay and Auto-Arm Warning periods, for the lobby partition, (fields 2*05 and 2*06) combined are longer than that of any other partition that affects the lobby. This causes the lobby to arm last. Master Keypad Setup and Operation Although this system has eight actual partitions, it provides an extra partition strictly for the purpose of assigning keypads as Master keypads for the system. Assigning any keypad to Partition 9 in Device Programming in the #93 Menu Mode makes that keypad a Master keypad. A Master keypad reflects the status of the entire system (Partitions 1-8) on its display at one time. This is useful because it eliminates the need for a building security officer to have to log on to various partitions from one partition's keypad to find out where an alarm has occurred. The following is a typical display: S Y S T E M 1 2 3 4 5 6 7 8 S T A T U S R R N N A ✴ B Possible status indications include: A = Armed Away S = Armed Stay M = Armed Maximum C = Comm Fail I = Armed Instant R = Ready N = Not Ready B = Bypassed/Ready ✴ = Alarm T = Trouble F = Fire Alarm P = AC Power Failure L = Low System Battery To obtain more information regarding a particular partition, enter [✴] + Partition No. (e.g., [✴] + [4]). This allows viewing only of that partition. In order to affect that partition, the user must use a code that has access to that partition. Also, in order for a user of any partition to log on to Partition 9 to view the status of all partitions, that user must have access to all partitions. Otherwise, access is denied. The following is displayed for a fault condition on Zone 2 (Loading Dock Window) on Partition 1 (Warehouse) when a user logs on from a keypad on Partition 9: WHSE DISARMED HIT ✴ FOR FAULTS Pressing [✴] causes the following display to appear at Partition 1's keypad(s): FAULT 002 LOADING DOCK WINDOW Additional zone faults are displayed one at a time. To display a new partition's status, press [✴] + Partition No. The Armed LED on a Master keypad is lit only if all partitions have been armed successfully. The Ready LED is lit only if all partitions are "ready to arm." Neither LED is lit if only some partitions are armed and/or only some partitions are ready. VISTA-128BP/VISTA-250BP Installation and Setup Guide 2-4 Press [✴] + [0] or [✴] + [9] to return to the master partition. Otherwise, if no keys are pressed for 2 minutes, the system automatically returns to the master partition The sounder on a Master keypad reflects the sound of the most critical condition on all of the partitions. The priority of the sounds, from most to least critical, is as follows: 1. Pulsing fire alarm sounds 2. Steady burglar alarm sounds 3. Trouble sounds (rapid beeping) Silence the sounder by pressing any key on the Master keypad or a keypad on the partition where the condition exists. A Master keypad uses the same panics as Partition 1. Master keypad panics are sent to Partition 1, and will activate on Partition 1. Therefore, panics must be programmed for Partition 1. Panel Linking Up to eight VISTA-128BP/VISTA-250BP control panels may be networked, enabling a user to control the features of all control panels from a single location. The panel linking bus supports an end-to-end network length of up to 4,000 feet. This makes it ideal for multi-building environments (e.g., shopping mall, college campus, etc.). UL Panel Linking is not permitted in UL installations. Panel linking requires a VA8200 Panel Link Module (PLM) on each VISTA-128BP/VISTA-250BP. Users can link (access other control panels) in any of three different modes: Single-Partition, Single-Panel Mode; Multi-Partition, Multi-Panel Mode; Multi-Panel View Mode. These modes are described later in this section. Each PLM connects to the ECP bus on the control panel and communicates to each PLM via an RS-485 bus (3-wire twisted cable run) with a maximum wire- run of 4000 feet end-to-end. • Users 001-050 are the only users that can perform panel linking and are automatically assigned panel linking access when added to the system. • An alpha keypad must be used for panel linking. • The system may take up to 7 seconds to respond to a command when in a panel linking mode NOTE: A user cannot access partitions or panels that they have not been assigned to. Panel Link Module Supervision The Panel Link Module can be supervised for its connection to the control panel. The module’s supervisory zone is zone 8xx, where “xx” = the ECP address of the PLM. You must program that zone with response type 05 (Day/Night) in Zone Programming in the #93 Menu Mode (refer to the Programming Guide for detailed programming instructions). If you want to report the supervisory failure to the central station and/or to a paging service, the appropriate reporting parameters for that zone must be programmed. If you want the supervisory failure of PLM(s) on other linked control panels to display on this control panel, they must be programmed into Zone Programming in the #93 Menu Mode with response type 14 in this control panel (refer to the Programming Guide for detailed programming instructions). The panel ID number for each module must match the panel ID number programmed in Device Programming of its “host” VISTA-128BP/VISTA-250BP. How to Use Panel Linking Panel Linking can be used in any of three different modes: • Single-Partition, Single-Panel − displays status of a partition on a remote control panel and allows control of that remote control panel. • Multi-Partition, Multi-Panel Mode − displays status and allows arming/disarming of multiple partitions at once on a remote control panel. • Multi-Panel View Mode − displays status and allows arming/disarming of multiple remote control panels at a time. NOTE: A user will not be able to access or view partitions or panels that they have not been assigned to. VISTA-128BP/VISTA-250BP Installation and Setup Guide 2-4 Single-Partition Single-Panel Mode To access the Single-Partition, Single Panel mode, perform the following steps: Step Action 1 Enter User Code (for users 001-050) + [#] + [86]. 2 Enter the panel ID number (01-08) of the panel you want to link to. 3 Enter the partition number of the panel. The keypad displays “AWAITING PANEL LINK.” After a few seconds, the keypad displays the status of the partition along with the panel ID number and partition number flashing in the upper right-hand corner. The user now has full control of the remote control panel. All functions can be performed except the following: • Those limited by the user’s authority level. • The user cannot enter Installer Program mode. • The user cannot execute another panel linking mode. NOTE: To execute another panel linking mode or to access a different remote panel, the user must first exit this mode (return to the original control panel). 4 To exit, enter the User Code (for users 001-050) + [#] + [85]. After a few seconds, the keypad displays the status of the original partition for the keypad. Multi-Partition Multi-Panel Mode To perform a function in the Multi-Partition, Multi Panel mode, follow the steps below: Step Action 1 Enter User Code (for users 001-050) + [#] + [88]. The keypad displays the following: PANELnn 1 2 3 4 5 6 7 8 STATUS x x x x x x x x where “nn” = panel ID number (01-08), “12345678” are the partition numbers and “xxxxxxxx” is the status of each partition of that panel. Status indications include: A = Armed Away S = Armed Stay M = Armed Maximum I = Armed Instant R = Ready N = Not Ready B = Bypassed/Ready ✴ = Alarm T = Trouble F = Fire Alarm P = AC Power Failure L = Low System Battery C = Comm Fail NOTES: See table later in this section for priority of displays. A “•” under a partition number indicates the user does NOT have access to that partition. 2 The following functions can be performed: Press [1] to attempt to disarm all partitions. Press [2] to attempt to arm AWAY all partitions. Press [3] to attempt to arm STAY all partitions. Press [4] to attempt to arm MAXIMUM all partitions. Press [7] to attempt to arm INSTANT all partitions. Press [✴] to read the status of the next panel. Press [#] key to read the status of the previous panel. Press [0] to exit mode. After a few seconds, the keypad displays the status of the original partition of the original panel for the keypad. Also, this mode will end in approximately 120 seconds if no keys are pressed. NOTES: When performing any of the arming commands, if there are faults in any of the partitions, none of the partitions will arm. These faults must be corrected or bypassed before attempting to arm. When performing either a STAY or INSTANT arm command the system always arms in mode VISTA-128BP/VISTA-250BP Installation and Setup Guide 2-6 1. The user cannot execute another panel linking mode. To execute another panel linking mode or to access a different remote panel, the user must first exit this mode (return to the original control panel). Multi-Panel View Mode To perform a function in the Multi-Panel View mode, follow the steps below: Step Action 1 Enter User Code (for users 001-050) + [#] + [87]. The keypad displays the following typical display: ALLPANEL 1 2 3 4 5 6 7 8 STATUS x x x x x x x x where “12345678” are the panel ID numbers and “xxxxxxxx” is the overall status of each panel. Status indications include: A = Armed Away S = Armed Stay M = Armed Maximum I = Armed Instant R = Ready N = Not Ready B = Bypassed/Ready ✴ = Alarm T = Trouble F = Fire Alarm P = AC Power Failure L = Low System Battery C = Comm Fail NOTE: See table later in this section for priority of displays. 2 The following functions can be performed:: Press [1] to attempt to disarm all partitions on all panels. Press [2] to attempt to arm AWAY all partitions on all panels. Press [3] to attempt to arm STAY all partitions on all panels. Press [4] to attempt to arm MAXIMUM all partitions. Press [7] to attempt to arm INSTANT all partitions. Press [0] to exit mode. After a few seconds, the keypad displays the status of the original partition of the original panel for the keypad. Also, this mode will end in approximately 120 seconds if no keys are pressed. NOTES: When performing any of the arming commands, if there are faults in any of the partitions of a panel, the system will not arm that panel, but will arm all the other partitions of the other panels. When performing either a STAY or INSTANT arm command, the system always arms in mode 1 (see the VISTA-128BP/VISTA-250BP User Guide for a detailed explanation of the STAY and INSTANT arming modes). The user cannot execute another panel linking mode. In order to perform another panel linking mode or to access a different remote panel, the user must first exit this mode (return to the original control panel). Priority of Displays for Multi-Partition and Multi-Panel Modes This table shows the priority of displays if more than one of these conditions exists at the same time. Priority Description Display Priority Description Display 1 Fire Alarm F 8 Not Ready N 2 All Other Alarms ✴ 9 Ready R 3 AC Loss P 10 Armed STAY S 4 Comm Fail C 11 Armed AWAY A 5 System Low Battery L 12 Armed INSTANT I 6 Trouble T 13 Armed MAXIMUM M Section 3 - Installing the Control 2-7 7 Bypass B 3-1 SECTION 3 Installing the Control •••••••••••••••••••••••••••••••••••••••••••••••• • This section describes the procedures for mounting and wiring the control panel and all the peripheral devices. NOTE: All references in this manual for number of zones, number of user codes, number of access cards, and the event log capacity, use the VISTA-250BP’s features. See SECTION 1: General Description for the table listing the differences between the VISTA-128BP and the VISTA-250BP control panels. Mounting the Control Cabinet To mount the control cabinet, perform the following steps: Step Action 1 Before mounting the circuit board, remove the metal knockouts for the wiring entry that you will be using. DO NOT ATTEMPT TO REMOVE THE KNOCKOUTS AFTER THE CIRCUIT BOARD HAS BEEN INSTALLED. 2 Using fasteners or anchors (not supplied), mount the control cabinet to a sturdy wall in a clean, dry area that is not readily accessible to the general public. The back of the cabinet has 4 holes for this purpose. UL To provide certificated burglary service for UL installations, refer to the special requirements and Figure 3-2 Cabinet Attack Resistance Considerations to follow. For UL Commercial Burglary installations that require ATTACK RESISTANCE, use the cabinet included in the VISTA-ULKT kit. Installing the Cabinet Lock 1. Remove cabinet door, then remove the lock knockout from the door. Insert the key into the lock. 2. Position the lock in the hole, making certain that the latch will make contact with the latch bracket when the door is closed. 3. When correctly positioned, push the lock until it is held securely by its snap tabs. Use an ADEMCO No. K4445 Lock (supplied). CABINET DOOR BOTTOM LOCKED UNLOCKED ca b _ l o c k _ s n a p - 0 0 1 - V 0 AD E M C O AD E M C O PUSH SNAP TAB SNAP TAB PUSH ON LOCK UNTIL IT IS SEATED SECURELY STEP 2STEP 1 CHECK POSITION Figure 3-1: Installing the Lock Grade A Mercantile Premises Listing Guidelines • The panel door must be supervised. Mount the clip-on tamper switch (supplied) to the cabinet's right side wall as shown in the diagram below, and wire it to one of the hardwire zones. • Use a bell with a tamper-protected housing such as the ADEMCO AB12. The bell housing's tamper switch and inner tamper linings must also be wired to the hardwire zone. • Assign the tampers’ hardwire zone to a burglary partition. Program the hardwire zone for day trouble/night alarm (zone type 5) when only one burglary partition is used. Program it for 24-hr. audible alarm (zone type 7) when more than one burglary partition is used. • All wiring between the bell and panel must be run in conduit. Remaining wires do not need to be run in conduit. • All wiring that is not run in conduit must exit from the knockout openings on the bottom or back of the cabinet. • All unused knockouts must be plugged using the disc plugs and carriage bolts (supplied), as indicated in the diagram below. VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-2 • Fasten the cabinet door to the cabinet backbox using the 18 one-inch-long Phillips-head screws (supplied) after all wiring, programming, and checkout procedures have been completed. PC BOARD (Shows typical local Grade A listing installation) RUN BELL WIRES IN CONDUIT PLUG THIS KNOCKOUT PLUG THIS KNOCKOUT PLUG THIS KNOCKOUT PLUG THIS KNOCKOUT RUN ALL REMAINING WIRE THROUGH HERE CLIP-ON DOOR TAMPER SWITCH CABINET MOUNTING HOLE (4 PLACES) TO PLUG AN UNUSED KNOCKOUT OPENING, REMOVE KNOCKOUT AND INSTALL A PAIR OF DISC PLUGS AND A CARRIAGE BOLT AS SHOWN. KNOCKOUT OPENING HEX NUT AND WASHER DISC PLUGS (DIMPLES IN DISC PLUG SHOULD REGISTER INSIDE KNOCKOUT OPENING) CARRIAGE BOLT CABINET SIDE WALL (OUTSIDE) cabattack-001-V0 Figure 3-2: Cabinet Attack Resistance Considerations Grade A Mercantile Safe and Vault Listing Guidelines • Follow the guidelines given above for Grade A Mercantile Premises listing. • Mount a shock sensor such as Sentrol No. 5402 to the control's backbox. Follow the manufacturer's instructions for proper sensor mounting. This sensor also must be wired to a hardwire zone. • For safe and vault applications, a UL Listed contact must be used inside the cabinet through one of the knockouts for pry-off tamper purposes. This sensor also must be wired to a hardwire zone. Installing the Control's Circuit Board To install the circuit board in the cabinet, perform the following steps: Step Action 1 Hang the three mounting clips on the raised cabinet tabs. Refer to Figure 3-3 (Detail B). Make sure the clip orientation is exactly as shown in the diagram to avoid damage. This will also avoid problems with insertion and removal of the PC board. 2 Insert the top of the circuit board into the slots at the top of the cabinet. Make certain that the board rests in the slots as indicated (Detail A). 3 Swing the base of the board into the mounting clips and secure the board to the cabinet with the accompanying screws. Notes: • Make certain that the mounting screws are tight. This ensures that there is a good ground connection between the PC board and the cabinet. • Dress field wiring away from the microprocessor (center) section of the PC board. Use the loops on the left and right sidewalls of the cabinet for anchoring field wiring using tie wraps (Detail C). These steps are important to minimize the risk of panel RF interference with television reception. + + + DETAIL C SIDE VIEW OF SLOTS DETAIL A SIDE VIEW OF BOARD INSERTED INTO SLOTS DETAIL B SIDE VIEW OF SHORT MOUNTING CLIPS (TYP.) hi_end_mnt-PCB VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-4 Figure 3-3: Mounting the PC Board Installing the Keypads • Up to 31 addressable keypads (addresses 00-30) may be used (you may need to use an auxiliary power supply if the 750mA aux. output is exceeded). The following keypads may be used: • 2-line alpha display, 6139/6160/6160V NOTE: Refer to the Alpha Vocabulary list found in the #93 Menu Mode in the Programming Guide for list of the words annunciated by the 6160V. To wire the keypads, perform the following steps: Step Action Determine wire gauge by referring to the Wire Run Length/Gauge table below. Wire Run Length/Gauge Table Wire Gauge Length #22 gauge 450 feet #20 gauge 700 feet #18 gauge 1100 feet #16 gauge 1750 feet 1 2 Wire keypads to a single wire run or connect individual keypads to separate wire runs. The maximum wire run length from the control to a keypad, which is homerun back to the control must not exceed the lengths listed in the table. 3 Run field wiring from the control to the keypads (using standard 4-conductor cable of the wire gauge determined in step 1). 4 Connect the keypad(s) to terminals 6, 7, 8, and 9 on the control board, as shown in Figure 3-4. • The length of all wire runs combined, regardless of the wire gauge, must not exceed 2000 feet when unshielded quad conductor cable is used (1000 feet if unshielded cable is run in conduit, which acts a shield, or if shielded cable is used). • If more than one keypad is wired to one run, then the above maximum lengths must be divided by the number of keypads on the run (e.g., the maximum length is 225 feet if two keypads are wired on a #22 gauge run). KEYPADS BLACK RED GREEN YELLOW CONTROL TERMINALS 6 7 8 9 Figure 3-4: Keypad Connections to Control Panel VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-4 Addressing the Keypads The keypads will not operate until they are physically addressed and enabled in the system's Device Programming in the #93 Menu Mode. Set each keypad for an individual address (00-30) according to the keypad's instructions. Set an alpha keypad for address 00 and other keypads for higher addresses (00 and 01 are enabled in the system's default program). Any keypads set for address 02 and above will appear blank until they are enabled in the system's program. Each keypad must be set for a different address. • Do not set any keypads to address 31 (nonaddressable mode). They will interfere with other keypads (as well as other devices) connected to the keypad terminals. • If an “OC” or “OPEN CIRCUIT” message is present on a keypad, data from the control is not reaching the keypad. Check your wiring. Supplementary Power Supply for Additional Keypads When the control’s auxiliary power load for all devices exceeds 750mA, you can power additional keypads from a regulated 12VDC power supply (e.g., ADEMCO AD12612 (1.2A)). Use a UL Listed, battery-backed supply for UL installations. Connect the additional keypads as shown in Figure 3- 5, using the keypad wire colors shown. Be sure to observe the current ratings for the power supply used. • Make connections directly to the screw terminals as shown in Figure 3-5. Make no connection to the blue wire (if present). • Be sure to connect the negative (–) terminal on the power supply unit to terminal 7 (–) on the control. +–+ 6789 SUPPLEMENTARY POWER SUPPLY – CONTROL TERMINAL STRIP AUX.AUX.DATA IN DATA OUT IMPORTANT: MAKE THESE CONNECTIONS DIRECTLY TO SCREW TERMINALS AS SHOWN. RE D W I R E BL A C K W I R E YE L L O W W I R E GR E E N W I R E BL A C K W I R E RE D W I R E GR E E N W I R E YE L L O W W I R E pw r _ s u p p l y - 0 0 2 - V 0 TO MAIN KEYPAD TO SECONDARY KEYPAD Figure 3-5: Using A Supplementary Power Supply Installing External Sounders The VISTA-128BP/VISTA-250BP provides a bell circuit output for operating fire and burglary alarm notification appliances. The alarm output is rated as follows: 10VDC – 14VDC, 1.7A max., power-limited. UL • For Household Fire and combination Household Fire/Burglary installations, the total current drawn from the auxiliary power, polling loop, and alarm output combined must not exceed 750mA. • For Household Burglary installations, the total current drawn from the alarm output must not exceed 1.7A. A battery must be installed, as it supplies the current for the combined auxiliary power, polling loop, and alarm output in excess of 750mA. The output has the following options: • Selectable for supervision. • Selectable for confirmation of arming ding. • Selectable to chime when entry/exit or perimeter zones are faulted. • Selectable for no timeout or timeout of 2-30 minutes. UL Burglary bell circuits must be programmed for a timeout of 16 minutes or longer. UL985 Household Fire or Combination Household Fire/Burglary Installations For installations that must provide UL Listed protection, the total combined current drawn from the alarm output, auxiliary power output, and polling loop must not exceed 750mA in order to comply with the battery independence requirements. If, for example, two System Sensor PA400 piezo alarm sounders, wired in parallel, are used (24mA total), then 726mA (750mA – 24mA) is available for auxiliary output and polling loop use. UL1023 Household Burglary Installations For Household Burglary installations, the total current drawn from the alarm output must not exceed 1.7A. A battery must be installed, as the battery supplies current from the combined auxiliary power, polling loop, and alarm output in excess of 750mA. Non-UL Installations For non-UL installations, the total current drawn from this output can be up to 1.7 amps. A battery must be installed, as the battery supplies current in excess of 750mA. Up to two 719 sirens can be used wired in parallel. Section 3 - Installing the Control 3-5 UL This control complies with National Fire Protection Association (NFPA) requirements for temporal pulse sounding of fire notification appliances. Alarm Output Supervision When supervision is enabled, the VISTA- 128BP/VISTA-250BP monitors the alarm output wiring for open and short circuit faults while the output is inactive. The system provides a trouble indication (Zone 970) when an open occurs; or when a short occurs between the Bell (+) and Bell (-) terminal wiring, or between the Bell (+) terminal wiring and earth ground. UL NOTE: When supervising the bell output (zone 970), only one device can be connected to the alarm output (terminals 4 and 5) for UL and Fire installations. The VISTA-128BP/VISTA-250BP indicates the trouble condition regardless of whether the system is armed or disarmed. The zone displays on the keypads, reports to the event log, and transmits to the central station (if programmed) on Partition 1. The Contact ID event code is 321, Bell Trouble. The trouble is cleared from the display by entering the user code + OFF. Wiring the Alarm Output The wiring of the alarm output depends upon whether you are going to supervise the output or not. Use the appropriate procedure below for your application. UL Use only UL Listed sounding devices for UL installations. Compatible Alarm Indicating Devices Model Number Device Type Polarizing Diode 719 Compact Outdoor Siren (not UL Listed) Yes 747 Indoor Siren Yes AB12 Grade A Bell Yes System Sensor MA 12/24D Fire Piezo Horn No System Sensor P12575 Fire Horn/Strobe No Wheelock AS-121575W Fire Horn/Strobe No ALARM SOUNDER OUTPUT:1-VDC - 13.8VDC1.7A MAXIMUM BELL HORN 76 +- +-83124 fir e _ d e v i c e s - 0 0 1 - V 0 5 Figure 3-6: Wiring Polarized Fire Devices PANEL BELL PANEL BELL TO OTHER DEVICES NONPOLARIZED BURGLARY INDICATING DEVICES POLARIZED FIRE INDICATING DEVICE POLARIZING DIODES (MUST MOUNT AT INDICATING DEVICE) BELL BELL HORN non_polar_devices Figure 3-7: Wiring Nonpolarized Burglary Devices Supervising the Alarm Output To wire the alarm output using the supervision feature, perform the following steps: Step Action 1 Wire polarized fire-indicating devices to the alarm output as shown in Figure 3-6. 2 Wire nonpolarized burglary indicating devices to the alarm output using a polarizing diode (two 2A diodes supplied), as shown in Figure 3-7. 3 Program Zone 970 with a response type of 05 (trouble by day/alarm by night). NOTE: When supervising the bell output (zone 970), only one device can be connected to the alarm output (terminals 4 and 5) for UL and Fire installations. The minimum load on the alarm output must exceed 5mA at 12V for proper supervision operation. UL If a device such as a siren driver with a high- resistance trigger input (drawing less than 5mA) is used in a UL Household Fire installation, the siren driver must independently supervise siren speaker wiring. Section 3 - Installing the Control 3-5 Using a Siren Driver To install a siren driver, perform the following steps: Step Action 1 Mount the siren driver in the panel’s cabinet. 2 Wire the siren driver to the control and to the speaker(s). (See the driver’s instructions.) 3 Cut the blue jumper on the upper left-hand corner of the panel’s PC board. 4 Program Zone 970 with no response type (00). Disabling the Supervision of the Alarm Output To install the alarm output and disable the supervision feature, perform the following steps: Step Action 1 Wire the devices to terminals 4 and 5, observing polarity if necessary. 2 Cut the blue jumper on the upper left-hand corner of the panel’s PC board. 3 Program Zone 970 with no response type (00). Telephone Line Connections Connect the main dialer output to telephone company lines using the RJ31X cables supplied. UL The telephone line inputs have overvoltage protection in accordance with UL1459, as specified in UL985/UL1023. The system is shipped defaulted for Contact ID format. It is the only format capable of uniquely reporting all 250 zones, as well as openings and closings for all 250 users. This requires central stations to be equipped with the ADEMCO 685 receiver using software level 4.10 or higher. If you need an update, contact your distributor. To prevent the risk of shock, disconnect phone lines at the telco jack before servicing. If the communicator is connected to a PABX, be sure it has a backup power supply that can support the PABX for 24 hours (central station) or 60 hours (remote station). Many PABXs are not power-backed up, and this can result in a communication failure if power is lost. Reporting Formats The system supports the following formats: ADEMCO Low Speed 3+1; 4+1; 4+2; Sescoa/Radionics 3+1; 4+1; 4+2; ADEMCO 4+2 Express; ADEMCO High Speed; ADEMCO Contact ID TERMINALS ON CONTROL EARTH GROUND INCOMING TELCO LINE Handset TI P RI N G RJ31X JACK PLUG DIRECT CONNECT CORD TIP RING GR O U N D PREMISES PHONES {{ BR O W N ( T I P ) GR E Y ( R I N G ) GR E E N ( T I P ) RE D ( R I N G ) 2627282930 Incoming Telco Line Figure 3-8: Telephone Line Connections Wiring Burglary, Panic and Smoke Detector Devices to Zones 1-9 VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-6 The maximum zone resistance is 100 ohms for zones 1 and 8, and 300 ohms for all other zones (excluding the 2K EOL resistor). To wire burglary and panic devices to zones 1-9, connect sensors/contacts to the hardwire zone terminals (10 through 23). See Figure 3-9. Connect N.C. and N.O. devices as follows: • Connect N.C. devices in series with the high (+) side of the loop. The 2K EOL resistor must be connected in series with the devices, following the last device. • Connect N.O. devices in parallel (across) the loop. The 2K EOL resistor must be connected across the loop wires at the last device. ++- N.C.N.C. N.O. 2k EOLR2k EOLR +-++- N.C.N.C. 2k EOLR2k EOLR ++- N.C. ++- N.C.N.C. 2k EOLR SMOKE Zone resistance (Excluding EOLR): ZONE 1,8: 100 OHMS MAXIMUM ALL OTHER ZONES: 300 OHMS MAXIMUM ZONE 1 ZONE 2ZONE 3ZONE 4ZONE 5ZONE 6ZONE 7ZONE 8ZONE 9 2- W I R E S M O K E DE T E C T O R L O O P ( A l s o s u p p o r t s N O / N C B u r g c o n t a c t s ) LA T C H I N G T Y P E G L A S S BR E A K D E T E C T O R S 1011121314151617181920212223 N.C. N.O. N.O.N.O. 2k EOLR N.O.N.O. N.O. N.C. N.O. 2k EOLR 2k EOLR N.C. GLASS BREAKFireUsage Burg.Usage Red Jumper Zone response time:ZONES 1-9: 350mSec-500mSecZONE 9: Also Programmable for RS232 inputhw - z o n e s - 0 0 2 - V 0 Figure 3-9: Wiring Connections for Zones 1-9 Using 2-Wire Smoke Detectors on Zone 1 Zone 1 can support up to 16 2-wire smoke detectors. The alarm current on zone 1 supports only one smoke detector in the alarmed state. Compatible 2-Wire Smoke Detectors DETECTOR TYPE DEVICE MODEL # Photoelectric, direct-wire System Sensor 2400 Photoelectric w/heat sensor, direct-wire System Sensor 2400TH Photoelectric w/B401B base System Sensor 2451 Photoelectric w/heat sensor & B401B System Sensor 2451TH Ionization, direct-wire System Sensor 1400 Ionization w/B401B base System Sensor 1451 Photoelectric duct detect (DH400 base) System Sensor 2451 Photoelectric duct detect (DH400 base) System Sensor 2451 Ionization duct detector (DH400 base) System Sensor 1451DH Ionization, direct-wire System Sensor 1100 Ionization w/B110LP base System Sensor 1151 Photoelectric, direct-wire System Sensor 2100 Photoelectric w/heat sensor, direct-wire System Sensor 2100T Photoelectric w/B110LP base System Sensor 2151 UL These smoke detectors are UL Listed for use with the VISTA-128BP/VISTA-250BP and are the only 2-wire smoke detectors that may be used. Wiring 2-Wire Smoke Detectors to Zone 1 2K EOL resistors must be used on fire zones and must be connected across the loop wires of each zone at the last detector. To wire 2-wire smoke detectors to zone 1, perform the following steps: Step Action 1 Select up to 16 2-wire smoke detectors from the list of compatible detectors. 2 Connect 2-wire smoke detectors across zone 1 terminals (10 and 11) as shown in Figure 3-10. Observe proper polarity when connecting the detectors. 3 Connect the EOL resistor at the last detector in the loop across the zone 1 terminals. The EOL resistor must be connected across the loop wires at the last detector. VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-8 2k E O L R ZO N E 1 SM O K E (+) (-) 2-WIRE SMOKE DETECTOR 10 11 (+) (-) Figure 3-10: 2-Wire Smoke Detector on Zone 1 Using 4-Wire Smoke Detectors on Zones 1-8 You may use as many 4-wire smoke detectors as can be powered from the panel's Auxiliary Power output without exceeding the output's rating (750mA). • NFPA limits the number of 4-wire smoke detectors to 18 per zone. • Auxiliary power to 4-wire smoke detectors is not automatically reset after an alarm, and therefore must be momentarily interrupted using either the J7 smoke detector reset output trigger or a 4204 Relay Module. Compatible 4-Wire Smoke Detectors Use any UL Listed 4-wire smoke detector that is rated for 10-14VDC operation and that has alarm reset time not exceeding 6 seconds. Some compatible 4-wire smoke detectors are listed below. Detector Type Detector Model # Photoelectric, direct wire System Sensor 2412 Photoelectric w/heat sensor, direct wire System Sensor 2412TH Ionization, direct wire System Sensor 1412 Wiring 4-Wire Smoke Detectors UL Power to 4-wire smoke detectors must be supervised with an EOL device (use a System Sensor A77-716B EOL relay module connected as shown in Figure 3-11). To wire 4-wire smoke detectors to zones 1-8, perform the following steps: Step Action 1 Select 4-wire smoke detectors (see list of compatible detectors shown previously). 2 Connect detectors (including heat detectors, if used) across terminals of the zone selected. All detectors must be wired in parallel. See Figure 3-11. NOTE: If you are using the J7 output trigger to reset the smoke detectors, refer to Smoke Detector Reset on page 3-20 later in this section for the wiring instructions. 3 Connect the EOLR at the last detector in the loop across the zone’s terminals. You must connect the EOLR across the loop wires at the last detector. + + + + + HEAT DETECTOR 4-WIRESMOKEDETECTORS V128BP-002-V0 NO CONNECTION C NC NO RESET RELAY 1, 2, 3, OR 4 4204 RELAY MODULE NOTES: · PROGRAM THE RELAY TO TRANSFER ON FIRE ZONE RESET (ACTIVATION CODE 54). SEE 4204 RELAY MODULE SECTION FOR DETAILS. · SECOND CODE AND OFF ENTERED AT CONSOLE MOMENTARILY INTERRUPTS DETECTOR POWER. SHOWN POWERED. RELAY OPENS WHEN POWER IS LOST. EOL POWER SUPERVISION RELAY MODULE A77-716B 2kEOLR TO FIRE ZONE TERMINALS TO AUXILIARYPOWERTERMINALS Figure 3-11: 4-Wire Smoke Detectors Using Smoke Power Reversal Module The 333 PRM Polarity Reversing Module is used to reverse the polarity of the positive and negative voltages powering smoke detectors. The module is for use with 4-wire smoke detectors that employ a sounder and voltage-reversing feature. The module is triggered by a pulsing bell output. Smoke Detectors Compatible with the 333PRM The 333PRM may be used with the System Sensor 2112/24AT and similar models with the required operating features previously stated. VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-2 The 333PRM reverses polarity to smoke detectors with Integral Temp-3 Sounders. Typically, in alarm, each draws 49-60mA of current. The control panel supplies only enough current for one smoke detector. In order to attach more than one, an external power supply and an external relay may be required. Installing the 333 PRM Mount the 333 PRM inside the control panel’s cabinet or in a separate cabinet using the double-sided tape provided. Wire the 333PRM as shown in Figures 3-12a, b or c. Refer to the 333PRM Installation Instructions for detailed information on the installation of the module. -+ - + - + EOL POWER SUPERVISIONRELAY MODULEA77-761B 4-WIRE SMOKE DETECTORS 2000OHM EOLR TO FIRE ZONETERMINALS HEAT DETECTOR +– SHOWN POWERED. RELAY OPENS WHEN POWER IS LOST 33 3 P R M - 0 0 1 - V 0 33 3 P R M 7 6 5 4 3 -2 +1 8 JUMPER P1 NC MOMENTARY RESET SWITCH JUMPER P1 ON333 MODULE MUST BE IN "B" POSITION FOUR-WIRE DETECTOR CIRCUIT CONTROL PANEL 746 Figure 3-12a: Wiring a 333PRM to the Control -+ - + - + EOL POWER SUPERVISION RELAY MODULEA77-761B 4-WIRE SMOKEDETECTORS 2000 OHMEOLR TO FIRE ZONETERMINALS HEATDETECTOR +– SHOWN POWERED. RELAY OPENS WHEN POWER IS LOST 33 3 P R M - 0 0 2 - V 0 33 3 P R M 7 6 5 4 3 -2 +1 8 JUMPER NCCNO P1 JUMPER P1 ON 333 MODULEMUST BE IN"B" POSITION FOUR-WIRE DETECTOR CIRCUIT 4204 CONTROL PANEL 2 3 41 12 76 4 Figure 3-12b: Wiring a 333PRM using a 4204 Section 3 - Installing the Control 3-9 -+ - + - + EOL POWER SUPERVISION RELAY MODULEA77-761B 4-WIRE SMOKEDETECTORS 2000OHMEOLR TO FIRE ZONE TERMINALS HEATDETECTOR +– SHOWN POWERED. RELAY OPENS WHEN POWER IS LOST 33 3 P R M - 0 0 3 - V 0 PO W E R SU P P L Y 33 3 P R M 7 6 5 4 3 + -2 +1 8 JUMPER P1 USE A 12VDC,BATTERY-BACKED,UL LISTED POWERSUPPLY. JUMPER P1 ON333 MODULE MUST BE IN"B" POSITION FOUR-WIRE DETECTOR CIRCUIT 42 0 4 CONTROL PANEL 2 3 4 1 12 76 4 Figure 3-12c: Wiring a 333PRM using a 4204 and a Power Supply Using 2-Wire Latching Glassbreaks on Zone 8 Zone 8 can support 2-wire glassbreak detectors. The zone provides enough standby current to power up to 50 2-wire glassbreak detectors meeting the requirements listed below. Compatible Glassbreak Detectors Use detectors that meet the following ratings: Standby Voltage: 5VDC–13.8VDC Standby Resistance: Greater than 20k ohms (equivalent resistance of all detectors in parallel) Alarm Resistance: Less than 1.1k ohms (see note below) Alarm Current: 2mA–10mA Reset Time: Less than 6 seconds NOTES: • You can use detectors that exceed 1.1k ohms in alarm, provided they maintain a voltage drop of less than 3.8 volts in alarm. • The ADEMCO ASC-SS1 detector has been tested and found to be compatible with these ratings. 21 22 GLASSBREAK DETECTOR ZONE 8 (+) (-) LATCHING TYPE GLASS BREAK DETECTOR LOOP 2000 OHMS EOLR Figure 3-13: Wiring Latching Glassbreaks to Zone 8 • The alarm current provided by zone 8 supports only one glassbreak detector in the alarmed state. • Do not use other contacts when using glassbreak detectors on zone 8. Other contacts may prevent proper glassbreak detector operation. To wire 2-wire latching glassbreak detectors to zone 8, perform the following steps: Step Action 1 Select 2-wire glassbreak detectors that meet the requirements stated previously. 2 Connect detectors across zone 8 (terminals Section 3 - Installing the Control 3-11 21 and 22). See Figure 3-13. 3 Connect the EOL resistor at the last detector in the loop across the zone’s terminals. You Tamper Supervision for the Hardwired Zones The system can be programmed to monitor for either an open condition or a short condition of a tamper switch on zones 1-8. End-of-line supervision is required for this option. Wiring a Tamper Switch to Zones 1-8 The wiring of the tamper switch depends on whether the tamper switch and the sensor are normally open or normally closed. • If you are using a normally closed sensor, the tamper switch must be normally open. Refer to Figure 3-14 for the wiring configuration. • If you are using a normally open sensor, the tamper switch must be normally closed. Refer to Figure 3-15 for the wiring configuration. • For the normally closed sensor, program the zone for trouble on short. For the normally open sensor, program the zone for trouble on open. To wire a tamper switch on a hardwired zone, connect the EOL resistor at the last detector in the loop across the zone’s terminals. You must connect the EOL resistor at the last detector for proper operation of the tamper supervision. NOTE: For zones with a response type of 9 or 16 (Fire), the tamper selection must be “0” none. 2k EOLR + TAMPER SWITCH SENSOR Figure 3-14: Wiring a Normally Closed Loop for Tamper Supervision 2k EOLR + TAMPER SWITCH SENSOR Figure 3-15: Wiring a Normally Open Loop for Tamper Supervision Installing RPM Devices The polling loop provides both power and data to the RPM devices, and is constantly monitoring the status of all zones enabled on the loop. The maximum current draw of all devices on the polling loop cannot total more than 128mA (unless the system uses a 4297 Polling Loop Extender Module). Devices that can be programmed via either DIP switches or the built-in unique serial number must be set for the serial number mode operation. All devices on the polling loop must be wired in parallel to the [+] and [-] polling loop terminals of the control panel (24 and 25). You can wire from device to device, or have multiple branches connected directly to the control panel in a star configuration. Compatible Polling Loop Devices Model Number Type 4208 8-Zone Expander 4190WH 2-Zone Expander 4278 Quad PIR 4275 Dual PIR 4194 Surface-Mount Reed Contact (Wide Gap) 4297 Extender Module 4192SD Photoelectric Smoke Detector Devices 4192SDT Photoelectric Smoke Detector w/Heat Detector 4192CP Ionization Smoke Detector 4101SN Serial Number Single-Output Relay Module VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-12 4208U Universal 8-Zone Expander 4939SN-BR 4939SN-GY Serial Number Surface-Mount Reed Contacts 4191SN-WH Serial Number Recessed Reed Contact 4959SN Aluminum Overhead Door Contact 7500 Single Technology Glassbreak Detector 9500 Dual Technology Glassbreak Detector 4209U Universal Group Zoning Module 4193SN Serialized 2-Zone Expander 4293SN Serialized 1-Zone Expander 4190SN Serialized 2-Zone Expander 998MX Serialized PIR UL • The 4208 must be mounted either inside the control panel’s cabinet or in a separate enclosure that has a tamper-supervised cover. • The 4190WH right loop must not be used, and the left loop must be EOLR-supervised. • The 4278 right loop cannot be used. • The 4194 is not UL Listed. • The 4297 must be powered from the control panel’s Auxiliary Power Output or from a UL Listed supplementary power supply. • The 7500 and 9500 detectors are not UL Listed. • For new polling loop installations, always use twisted pair wiring. In many cases, existing non-twisted pair wiring may be used, but it is more susceptible to interference from other sources, and may be problematic in installations with long wire runs or in high noise environments. • Always locate polling loop wiring at least six inches (15cm) of AC power, telephone, or intercom wiring. The polling loop carries data between the control panel and the devices; interference on this loop can cause an interruption of communication. The polling loop can also cause outgoing interference on the intercom or phone lines. If this spacing cannot be achieved, shielded wire must be used. (Note that the maximum total wire length supported is cut in half when shielded wire is used.) • No more than 64mA may be drawn on any individual wire run. • When a star configuration is used, the total length of all wire runs combined cannot exceed 4000 ft (2000 ft. if you are using unshielded wire in conduit or shielded wire). IMPORTANT NOTE: If the installation needs to exceed or deviate from these parameters, refer to the application note on the Honeywell website for additional polling loop wiring configurations. To access the application note: 1. Go to the honeywell.com/security website 2. Click the Honeywell Security & Custom Electronics link. 3. Click the Commercial link. 4. Click the Documentation link. 5. Click the V-Plex Application Note. Section 3 - Installing the Control 3-13 To install polling loop devices, perform the following steps: Step Action 1 Select devices from the list of compatible devices shown previously. 2 Set the DIP switches in the device (if required). Refer to the device’s instructions. 3 Mount each device in the desired location. Refer to the device’s instructions. Run wires from the control panel to each device on the polling loop (see Figure 3-16). No individual wire run may exceed the lengths shown in the following table. Maximum Polling Loop Wire Runs Wire Gauge Max. Length #22 gauge 650 feet #20 gauge 950 feet #18 gauge 1500 feet #16 gauge 2400 feet 4 5 Wire each device to the polling loop, making sure of the correct polarity (refer to the device’s instructions). NOTE: If you are using serial number devices, and intend to enroll each device through the keypad automatically, wire no more than 25 of these devices to the control at a time. Then power up and program them before connecting the next 25. Leave previously enrolled devices connected. If you intend to manually enter the serial numbers via the keypad or the Compass downloading software, all the devices may be connected before powering up to program. POLLING LOOP RATING: 128mA MAXIMUM 4192SD SMOKE 4190RPM 4278PIR 232122 +- PO L L I N G L O O P 2524 TO RIGHT LOOP po l l _ l o o p - 0 0 1 - V 0 Figure 3-16: Polling Loop Connections to the VISTA-128BP/VISTA-250BP Polling Loop Supervision A short on the polling loop is indicated by a trouble on zone 997 and reports as a trouble condition only. If annunciation is desired, program the zone as type 05. If a device on the polling loop fails (the panel cannot "see" that device), the system displays a trouble condition for all zones on that device. If the panel is armed when a device fails, and the zone is a burglary zone, the will go into alarm A trouble on zone 997 prevents a partition from being armed, unless all polling loop zones on that partition are bypassed. Using the 4297 Polling Loop Extender The 4297 Polling Loop Extender may be used to provide additional polling loop current, to extend the polling loop wire run length, and/or to provide individual electrically isolated polling loops. Refer to Figures 3-17 and 3-18, to follow. DO NOT use the 4197 Polling Loop Extender module with the VISTA-128BP/VISTA-250BP. Be sure to include the total current drawn on the polling loop when figuring the total auxiliary load on the panel’s power supply. Section 3 - Installing the Control 3-13 CONTROL PANEL RPM INPUT POLLING LOOP EXTENSION POLLING LOOP RPM 4297 RPM RPM TO OTHER RPMS INPUT LOOP LIMITS: EXTENSION POLLING LOOP LIMITS = SAME AS INPUT LOOP •128 mA MAX. LIMIT CURRENT TO 64mA ON ANY INDIVIDUAL WIRE RUN. • NO MORE THAN 64 DEVICES MAY BE USED. NO INDIVIDUAL WIRE RUN CAN EXCEED: • • TOTAL LENGTH OF ALL WIRE RUNS COMBINED CANNOT EXCEED 4000FT. (2000FT. IF USING SHIELDED WIRE) GAUGE LENGTH #22 650 FT #20 950FT #18 1500 FT #16 2400 FT • NO MORE THAN119 DEVICES COMBINED. • TOTAL LENGTH OF ALL WIRE RUNS ON BOTH LOOPS COMBINED CANNOT EXCEED 6400 FT. 3200 FT. IF USING UNSHIELDED WIRE IN CONDUIT, OR IF USING SHIELDED WIRE po l l i n g _ l o o p _ 0 0 3 - V 2 COMBINED INPUT AND EXTENSION LOOP LIMITS: Figure 3-17: Polling Loop Connections Using One 4297 Extender Module CONTROL PANEL EXTENSION POLLING LOOP #1 4297 RPM COMBINED INPUT AND EXTENSION LOOPLIMITS: • NO MORE THAN 119 DEVICES COMBINED ON THE INPUT LOOP AND EXTENSION LOOP #1. NO MORE THAN 119 DEVICES COMBINED ON THE INPUT LOOP AND EXTENSION LOOP #2. • TOTAL LENGTH OF ALL WIRE RUNS ON THE INPUT LOOP AND EXTENSION LOOP #1 COMBINED CANNOT EXCEED 6400 FT. (3200 FT. IF USING UNSHIELDED WIRE IN CONDUIT, OR SHIELDED WIRE). TOTAL LENGTH OF ALL WIRE RUNS ON THE INPUT LOOP AND EXTENSION LOOP #2 COMBINED CANNOT EXCEED 6400 FT. (3200 FT. IF USING UNSHIELDED WIRE IN CONDUIT, OR SHIELDED WIRE). 4297 RPM INPUT POLLING LOOP • DO NOT CONNECT 4297 MODULES IN SERIES (i.e., DO NOT CONNECT ONE MODULE'S EXTENSION LOOP TO ANOTHER MODULE'S INPUT LOOP.) po l l i n g _ l o o p - 0 0 4 - V 1 EXTENSION POLLING LOOP #2 Figure 3-18: Polling Loop Connections Using Multiple Extender Modules NOTE: The input loop limits stated in Figure 3-17 apply to Figure 3-18 as well. Wireless Zone Expansion UL The 5881ENHC RF Receiver and the 5869 Holdup Switch Transmitter are listed for UL Commercial Burglary applications. All other RF receivers and transmitters are not listed for UL Commercial Burglary applications. The following table lists the receivers that may be used and the number of zones they support. 5800 Series Receivers Receiver Zones 5881L up to 8 5881M up to 16 5881H up to 250 In Canada, 5800 systems must use 5882 Series receivers: 5882L/5882H. Information to the 5881 Receivers applies as well to the 5882 Receivers. Both receivers use the same transmitters. RF System Operation and Supervision The 5800 RF system operation has the following characteristics: • The receiver responds to a frequency of 345MHz. • The receiver has a nominal range of 200 feet. • Supervised transmitters send a supervisory signal every 70-90 minutes. VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-14 • Zones 988 and 990 are used to supervise the RF reception of receivers 2 and 1, respectively. The reception is supervised for two conditions: 1. The receiver goes “deaf” (doesn’t hear from any transmitter) within a programmed interval of time (defined by program field 1*30). 2. Proper RF reception is impeded (i.e., jamming or other RF interference). The control checks for this condition every 45 seconds. UL A response type (05 Day/Night) must be programmed for zones 990 (1st receiver) and 988 (2nd receiver) for UL installations. • The 5881ENHC receiver contains front and back tampers that permit its use in commercial burglary installations. • You may only mount the 5881ENHC its own plastic housing. Otherwise, the receiver constantly reports a tamper condition. • The control checks the receiver connections about every 45 seconds. The receiver supervisory zone is 8 + 2-digit receiver device address (for example, Device address 05 = supervisory zone 805). NOTE: This zone must be programmed with a response type (e.g., type 05 Day/Night Trouble) before it supervise the connection to the receiver. • Use two identical receivers to provide either a greater area of coverage or redundant protection. They must be set for different addresses. • Any zone from 1 to 250 can be used as a 5800 Series wireless zone, with the exception of zone 64 (reserved for a wireless keypad). RF System Installation Advisories • Place the receiver in a high, centrally located area. Do not place it on or near metal objects. This will decrease the range and/or block transmissions. • Install the RF receiver at least 10 feet from the control panel or any keypads, to avoid interference from the microprocessors in these units. • If dual receivers are used: a. They must be at least 10 feet from each other, as well as from the control panel and remote keypads. b. Each receiver must be set to a different device address. The receiver set to the lower address is considered the 1st RF receiver for supervisory purposes. c. The House IDs must be the same. d. Using two receivers does not increase the number of transmitters the system can support (249 zones using the 5881H, plus a wireless keypad). Installation and Setup of 5881 RF Receivers Take note of the address you select for the RF receiver, as this address must be enabled in the system’s Device Programming in the #93 Menu Mode. 5881ENHC-001-V0 SCREW Figure 3-19: Installing the 5881ENHC with Tamper Protection To install the 5881 RF receiver, perform the following steps: Step Action 1 Mount the receiver, following the advisories stated previously. 2 Set the DIP switches in the receiver for the address (01-07). See Figure 3-20. Make sure the address setting is not being used by another device (keypad, relay module, etc.). 3 If installing a 5881ENHC, install a flat-head screw (supplied) in the case tamper tab as shown in Figure 3-19. When the receiver is pried from the wall, the tamper tab will break off and remain on the wall. This will activate a tamper switch in the receiver and cause generation of a tamper signal. Note that this signal will also be generated when the receiver’s front cover is removed. 4 Connect the receiver’s wire harness to the keypad terminals (6, 7, 8, and 9). Plug the connector at the other end of the harness into the receiver. 5 Refer to the Installation Instructions provided with the receiver for installations regarding antenna mounting, etc. Section 3 - Installing the Control 3-15 TO CONTROL'S REMOTE KEYPAD CONNECTION POINTS. USE MAX. of 220 ft. [67m of #22 (0.64mm) WIRE or 550 ft. (168m) of #18 (1mm) WIRE FOR EACH RUN. OBSERVE 20 ft. MAX. FOR COMMERCIAL FIRE INSTALLATIONS. (SEE RECEIVER'S INSTRUCTIONS.) DIP SWITCH WHITE AREAS = SWITCH HANDLES. POSITION 2-4 DETERMINE RECEIVER'S ADDRESS. CONSULT CONTROL'S INSTRUCTIONS FOR ADDRESS TO USE. DIP SWITCH BELOW SHOWN SET FOR ADDRESS "0." SWITCH POSITION RECEIVER ADDRESS SETTINGS (" - " MEANS OFF) 0 1 2 3 4 5 6 7 4 3 2 1 5 PRESENT ONLY ON 5881EH (SEE TEXT AT LEFT) ONONON ONON ONONONON ONON ON FOR FUTURE USEDIP SWITCH #5 (PRESET ONLY ON 5881EH) ON: SETS 5881EH FOR USE IN COMMERCIAL FIRE APPLICATIONS (SEE THE RECEIVER'S INSTRUCTIONS)*. OFF: USE IN NON-COMMERCIAL FIRE INSTALLATIONS. * FOR COMMERCIAL FIRE APPLICATIONS THE 5881EH PC BOARD MUST BE MOUNTED IN A SEPARATE CABINET (SEE RECEIVER'S INSTRUCTIONS FOR DETAILS). MOUNTING HOLES INSERT IN RIGHT-HAND TERMINALS CIRCUIT BOARD DIP SWITCH YELLOW RED BLACK GREEN INTERFERENCE INDICATOR LED WIRING OPENING PLUG & SOCKET ANTENNAS 58 8 1 - 0 0 1 - V 1 Figure 3-20: 5881 RF Receiver (cover removed) Installing the 5800TM Module Installation of this module is necessary only if you are using a 5827BD or 5804BD Bi-directional device. The address for the 5800TM must be enabled in the control’s Device Programming in the #93 Menu Mode as a keypad and then assigned to a partition. To install the 5800TM, perform the following steps: Step Action 1 Mount the unit using its accompanying mounting bracket near the RF receiver. The 5800TM must not be installed within the control cabinet. It must be between one and two feet from the receiver’s antennas. 2 Set the module for the appropriate address. For Address Setting 28 cut the red jumper; for Address 29 cut the white jumper; for Address 30 cut both jumpers. Make sure the address setting is not being used by another device (keypad, relay module, etc.). 3 Connect the module’s wire harness to the keypad terminals (6, 7, 8, and 9). Plug the connector at the other end of the harness into the module. House ID Sniffer Mode This mode applies only if you are using a wireless keypad (e.g., 5827) or bi-directional devices (e.g., 5804BD). Use the House ID Sniffer mode to make sure you do not choose a House ID that is in use in a nearby system. The House ID must be programmed for the receiver in Device Programming in the #93 Menu Mode. To enter House ID Sniffer mode, enter your Installer Code + [#] + [2]. The receiver now “sniffs” for any House IDs in the area and displays them. Keep the receiver in this mode for 2 hours. Use a House ID that is not displayed. Exit the Sniffer mode by entering your Installer Code + OFF. As Sniffer mode effectively disables RF point reception, Sniffer mode cannot be entered while any partition is armed. 5800 Series Transmitter Setup 5800 Series transmitters have the following characteristics: • Transmitters have built-in serial numbers that must be enrolled in the system using the #93 Menu Mode Programming, or input to the control via the downloader. • Transmitters do not have DIP switches (except 5827, described separately). • Some transmitters, such as the 5816 and 5817, can support more than one “zone” (referred to as loops or inputs). Each loop must be assigned a different zone number. VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-16 • For button-type transmitters (wireless keys), such as the 5804 and 5804BD, you must assign a unique zone number to each individual button used on the transmitter. Transmitter Input Types All transmitters have one or more unique factory- assigned input (loop) codes. Transmitters can be programmed as one of the following types: Type Description RM (RF Motion) Sends periodic check-in signals, as well as fault and low-battery signals. The control panel automatically restores the zone to “ready” after a few seconds. This type is designed for facilities with multiple motion detectors that may fault and restore simultaneously. The transmitter must remain within the receiver’s range. NOTE: If using RF Motion with a door/window type transmitter, only loop 1 may be used. RF (Supervised RF) Sends periodic check-in signals, as well as fault, restore, and low-battery signals. The transmitter must remain within the receiver’s range. UR (Unsupervised RF) Sends all the signals that the RF type does, but the control does not supervise the check-in signals. The transmitter may therefore be carried off-premises. BR (Unsupervised Button RF) These send only fault signals. They do not send low-battery signals until they are activated. The transmitter may be carried off-premises. Transmitter Supervision Supervised RF transmitters send a check-in signal to the receiver at 70–90 minute intervals. If at least one check-in is not received from each supervised transmitter within a programmed period (field 1∗31), the “missing” transmitter number(s) and “CHECK” or “TRBL” are displayed. Unsupervised RF transmitters (5802MN, 5804) may be carried off the premises. Some transmitters have built-in tamper protection, and annunciate a “CHECK” or “TRBL” condition if covers are removed. If a loss of supervision occurs on a transmitter programmed for Fire, it reports in Contact ID as a Fire Trouble (373), not Loss of Supervision (381), to the central station. Transmitter Battery Life Batteries in the wireless transmitters may last from 4 to 7 years, depending on the environment, usage, and the specific wireless device being used. Factors such as humidity, high or low temperatures, as well as large swings in temperature may all reduce the actual battery life in a given installation. The wireless system can identify a true low battery situation, thus allowing the dealer or user of the system time to arrange a change of battery and maintain protection for that point within the system. Some transmitters (e.g., 5802, 5802CP, and 5803) contain long-life but nonreplaceable batteries. At the end of their life, the complete unit must be replaced (and a new serial number enrolled at the control). Button-type transmitters (e.g., 5801, 5802, 5802CP and 5803) should be periodically tested, as these transmitters do not send supervisory check-in signals. To test the transmitters using the Transmitter ID Sniffer mode and the Go/NoGo Test Mode, see SECTION 10: Testing the System for the procedures. Compatible 5800 Series Transmitters Model Product Input Type 5801 Panic Transmitter UR or RF 5802 5802CP Pendant (Personal Emergency Transmitter) Belt Clip (Personal Emergency Transmitter) BR Only 5802MN Miniature (Personal Emergency Transmitter) UR or RF 5802MN2 Miniature (Personal Emergency Transmitter) UR or RF 5804 Wireless Key Transmitter BR Only 5804BD Wireless Key Bi-directional Transmitter BR Only 5804BDV Wireless Key Bi-directional Transmitter with Voice BR Only Model Product Input Type 5806/5807/ 5808 Wireless Photoelectric Smoke Detectors RF 5816 Door/Window Transmitter RF 5816MN Miniature Door/Window Transmitter 5816TEMP Temperature Sensor Transmitter 5817 Multi-Point Universal Transmitter RF 5818 Recessed Transmitter RF 5827 Wireless Keypad House ID 5827BD Wireless Bi-directional Keypad House ID 5849 Glassbreak Detector RF 5850 Glassbreak Detector RF 5890 PIR Detector RF 5890PI PIR Detector with Pet Immunity RF Section 3 - Installing the Control 3-17 Installing Output Devices The VISTA-128BP/VISTA-250BP support up to 96 outputs. Each device must be programmed as to how to act (ACTION), when to activate (START), and when to deactivate (STOP). The 4204, 4204CF, FSA-8, FSA- 24, 4140SN and/or X-10 devices may be used as output devices. Installing 4204 and 4204CF Relay Modules Each 4204 module provides 4 relays with Form C (normally open and normally closed) contacts. Each 4204CF module adds two style Y supervised bell outputs to the system. For 4204CF modules, only relays 1 and 3 on each module can be programmed. The relay module will not operate until the device address you have set the DIP switches for is enabled in the control’s Device Programming in the #93 Menu Mode. To install the relay modules, see Figures 3-21 and 3-22 and perform the following steps: Step Action 1 Set the 4204 or 4204CF’s DIP switches for a device address 01-15. Do not use an address being used by another device (keypads, RF receivers, etc.). 2 Mount the 4204 and 4204CF Modules per the instructions provided with them. Connect the module’s wire harness to the control (6, 7, 8, and 9). Plug the connector (other end of harness) to the module. If you are mounting remotely, homerun each module to the control. The table below shows the maximum wire run lengths. Refer to the instructions provided with the 4204CF for its maximum permissible wire lengths. Wire Gauge Maximum Length #22 125 feet #20 200 feet #18 300 feet #16 500 feet 3 SWITCH4204 ADDRESS SETTINGS POSITION("—" means "OFF") 0123456789101112131415 2 ON —ON —ON —ON —ON —ON —ON —ON — 3 ONON ——ONON ——ONON ——ONON —— 4 ONONONON ————ONONONON ———— 5 ONONONONONONONON ———————— ON12 3 4 5 13141516 C NC NO OFF ON DIP SWITCHFOR SETTING DEVICE ADDRESS AND ENABLING/DISABLING TAMPER COVER TAMPER (REED)SWITCH TB1 4204 TB2 4-PIN CONSOLE PLUG 12 11 10 9 8 7 6 5 4 3 2 1 C NC NO C NC NO C NC NO RELAY 3 RELAY 2 RELAY 1 RELAY4 TYPICAL (SHOWN "OFF") EITHER OR BOTH CAN BE USED DATA INFROM CONTROL (–) GROUND DATA OUTTO CONTROL (+) 12V YEL BLK GRN RED Figure 3-21: 4204 Relay Module SWITCH4204CF ADDRESS SETTINGSPOSITION("—" means "OFF") 0123456789101112131415 2 ON —ON —ON —ON —ON —ON —ON —ON — 3 ONON ——ONON ——ONON ——ONON —— 4 ONONONON ————ONONONON ———— 5 ONONONONONONONON ———————— ON12 3 4 5 OFF ON 13141516 NC NC DIP SWITCH FOR SETTING DEVICE ADDRESS AND ENABLING/DISABLING TAMPER COVER TAMPER (REED)SWITCH TB1 TB2 4-PIN CONSOLE PLUG 12 11 10 9 8 7 6 5 4 3 2 1 NC NC NC NC EITHER OR BOTH CAN BE USED DATA INFROM CONTROL (–) GROUND DATA OUTTO CONTROL YEL BLK GRN RED (+) 12V; SUPPLIES POWER TO MODULECIRCUITRY (INCLUDING NOTIFICATIONAPPLIANCE RELAY COILS). CURRENTDRAIN AT 12V IS: 25 mA + (80 mA PER ACTIVE OUTPUT) NOTIFICATION APPLIANCE ANDCONSOLE DATA OUTPUTS AREPOWER LIMITED – + NOTIFICATIONAPPLIANCE B 2K EOLR #610-7 POLARIZED NOTIFICATIONAPPLIANCE– + NOTIFICATIONAPPLIANCE A 2K EOLR #610-7 }– +POWER FOR NOTIFICATION APPLIANCE A,NOTIFICATION APPLIANCE B8-28VDC OR VFW. UP TO 2.4ADEPENDING ON BELL CURRENT - ALARM POLARITYSHOWN - EACH OUTPUT PROVIDES STYLE Y SUPERVISION - EACH OUTPUTRATED 1.2A MAX - USE NOTIFICATION APPLIANCES COMPATIBLE WITH NOTIFICATION APPLIANCE POWER SUPPLY VOLTAGE RATING Figure 3-22: 4204CF Relay Module Installing FSA Modules The 8-zone LED Fire System Annunciator FSA-8 and 24-zone LED Fire System Annunciator FSA-24 enable a fire response unit to identify quickly the point/zone of a fire. These indicators may be used for other functions as well, such as status indication. A maximum of 4 FSA modules, in any combination, can be supported. The FSA module will not operate until the device address you have set the DIP switches for is enabled in the control’s Device Programming in the #93 Menu Mode. To install the FSA module, refer to Figure 3-23 and perform the following steps: Step Action 1 Set the FSA’s DIP switches for a device address from 08 to 23. See the module’s instructions for the DIP switch table. Do not use an address being used by another device (keypads, RF receivers, etc.). 2 Mount the FSA module horizontally to a duplex box (quad box for FSA-24). VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-18 3 Connect the module to the control’s keypad terminals (6, 7, 8, and 9). 00000 ECP Bus Dip SwitchOptional Keyswitch Connection SIDE VIEW All Switches shown in Up position. (ECP Address 23) Terminal Block Connect to Keypad Terminals Figure 3-23: Wiring the FSA Module Installing 4101SN Relay Modules The 4101SN V-Plex Single Output Relay Module is a serial number polling loop output device. The 4101SN features the following: • Form C relay contacts rated at 2A, 28VAC/VDC with contact supervision. The position of the relay is supervised, but not the actual external contact wiring. • One class B/style B EOLR-supervised auxiliary input zone. • Operating power and communication with control panels via the V-Plex polling loop. • Electronics mounted in a small plastic case with tamper-protected cover. Connect the device to the polling loop, terminals 24 (+) and 25 (-). Be sure to observe polarity Installing X10 Devices X-10 devices are either plugged into standard AC outlets or wired into the AC electrical system by a licensed electrician, depending on the type of device used. Note each device’s House and Unit Code setup, as these codes will be used to program the devices in Output Programming in #93 Menu Mode described in the Programming Guide. X-10 devices require the use of a 1361X10 transformer in place of the regular 1361 transformer. X-10 devices respond to “on” and “off” commands sent from the panel through the 1361X10 transformer. To connect the 1361X10 transformer, see Connecting the Transformer, later in this section. Installing the Ground Start Module UL The Ground Start Module is not intended for use in UL Listed applications. Output 1 may be used to trigger an optional 675 Ground Start Module for installations having telephone lines that require ground start instead of loop start operation to obtain a dial tone from the telco central office. When the panel has a message to transmit to the central station, it seizes the line, goes off hook, and then triggers the 675 Module to connect the RING side of the telephone line to earth ground. The panel causes the module to break the connection between RING and earth ground when it obtains a dial tone. You cannot use Output 1 for the Ground Start if you are using it for a Smoke Detector Reset or an AAV module. To install the 675 Ground Start Module, perform the following steps: Step Action 1 Determine which side of the telephone line is the RING side by connecting the (+) lead of a DC voltmeter to earth ground, and the (-) lead to one side of the telephone line. The wire that reads + 50VDC is the RING side. 2 Connect the 675 Ground Start Module to the panel’s J7 connector trigger output 1, to auxiliary power, and to the RING side of the telephone line as shown in Figure 3-24. VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-16 3 Program field 1✳46 Auxiliary Output Enable with a [0]. 12 3 4 5 6 7 8 9 4142TR CABLE GRAY (GROUND) YELLOW (OUT 1) RED (OUT 2) GREEN (GROUND) BROWN (OUT 3) BLUE (GROUND) BLACK (OUT 4) WHITE (GROUND) J7 CONNECTOR N/U IF USED: 1. OUT 1 IS NO LONGER USABLE FOR SMOKE DETECTOR RESET (SEE FIELD 1*46). 2. OUT 2, 3, 4 CAN STILL BE USED TO PROVIDE ALARM STATUS INDICATIONS OR TO OPERATE A KEYSWITCH (SEE FIELD *15). 3. THE 675 IS NOT UL LISTED. BR O W N GROUND START TRIGGER BLUE GR E E N BLACK VIOLET TO AUX. POWER TERM. 7 TO AUX. POWER TERM. 6 (50mA CURRENT DRAW) 675 GROUND START MODULE (CUT ORANGE JUMPER) TO TELCO RING TO EARTH GROUND Figure 3-24: Ground Start Module Connections Installing a Remote Keyswitch A UL-Listed remote keyswitch, such as the ADEMCO 4146, can be used for remote arming/disarming of the burglary portion of the system and for silencing alarms. The keyswitch can operate in only one particular partition. The keyswitch is wired across zone 7. This zone is no longer available as a protection zone. Be sure to program Zone 7 with a response type (e.g., type 10). Operation • A momentary short across zone 7 arms the partition in the AWAY mode, and a short held for more than 10 seconds arms the partition in STAY mode 1. A subsequent short disarms the partition. • The keyswitch LEDs indicate the partition’s status (see table below). • A momentary short across Zone 7 silences alarm bell and keypad sounds, and disarms the system if it was armed. A subsequent short across Zone 7 clears the alarm memory indication and resets 2- wire smoke and glassbreak detectors (if used). LED Indications Green Red Indication On Off Disarmed & Ready Off Off Disarmed & Not Ready Off On Steady Armed Away Off Slow Flash Armed Stay Off Rapid Flash Alarm Memory The keyswitch reports as user 0, if Open/Close reporting is enabled in field ✳40. Keyswitch Tamper Operation The tamper switch need not be used for fire or UL Household Burglary installations. For UL Commercial Burglary installations, the tamper switch must be wired to a zone (zone 6 in Figure 3-25). Program that zone for Day Trouble/Night Alarm (response type 5). When the keyswitch is removed from the wall, the tamper switch opens, causing an alarm or trouble on the zone. This also causes the control to disable keyswitch operation until the tamper is restored and the associated partition is disarmed. Wiring for the Remote Keyswitch To install the ADEMCO 4146 keyswitch, perform the following steps: Step Action 1 Connect the ADEMCO 4146 to the panel as shown in Figure 3-25. 2 If you are using the tamper, make sure it is connected to a zone. VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-20 2K ELOR 2K ELOR TAMPER SWITCH(CONTACTS CLOSE WHEN SWITCH DEPRESSED). LOCK SWITCH (NORMALLY OPEN) + TO J7 / OUT 2 TO J7 / OUT 4 TO AUX POWER (TERMINAL 6) ZONE ZONE TO ZONE 7 (+) (TERMINAL 20) YELLOWWHITE GREEN (READY) RED (ARMED) REDBLACK 820 ohms 820 ohms J7_keyswitch Figure 3-25: Remote Keyswitch Wiring Smoke Detector Reset Output 1 may be used to reset 4-wire smoke detectors. Use this output to trigger a low current relay, and wire the power for the smoke detectors through the relay’s contacts. NOTE: The output is normally high (12VDC) and goes low when the User Code + Off is entered at the keypad. To install a relay for smoke detector reset, perform the following steps: Step Action 1 Connect power terminals of the relay to the panel’s auxiliary power (terminals 6 & 7). 2 Connect trigger input of the relay to Output 1 on J7. 3 Connect the “pole” (common) of the relay to terminal 6 of the control. 4 Connect the positive side of the smoke detectors to the normally closed contact of the relay. 5 Connect the negative side of the smoke detectors to terminal 7 of the control. Remote Keypad Sounder This feature is available in the VISTA-128BP only. An optional Amseco PAL 328N Piezo Sounder can be used to duplicate the sounds produced by the keypad's built-in sounder. The panel will remote all sounds (e.g., alarm, trouble, chime, entry/exit, etc.) produced by the keypad's built-in sounder except for the short beeps associated with keypad key depression. One application of this feature might be to produce chime sounds at a distant location from the panel's keypads. Remote Keypad Sounder Setup To setup for a remote keypad sounder, connect the piezo sounder to the panel’s positive auxiliary power output and to Output 1 on the J7 connector as shown in Figure 3-26. To duplicate the keypad sounds for a particular partition, program that partition number in field ✳15. Program field 1✳46 Auxiliary Output Enable with a [2]. 1 2 3 4 5 6 7 8 9 GRAY (GROUND) YELLOW (OUT 1) WHITE (GROUND) RED (OUT 2) GREEN (GROUND) BROWN (OUT 3) BLUE (GROUND) BLACK (OUT 4) J7 CONNECTOR IF USED. 1. OUT 1 IS NO LONGER USABLE FOR SMOKE DETECTOR RESET OR GROUND START (SEE FIELD 1*46). 2. OUT 2 & 4 CAN NO LONGER BE USED TO PROVIDE ALARM TRIGGERS. N/U 4142TR CABLE BLACK – AMSECO PAL-328NPIEZO SOUNDER + REDTO AUX POWER + TERMINAL 6 10mA CURRENT DRAIN) J7_trigcon-001-V1 Figure 3-26: Remote Keypad Sounder Wiring Section 3 - Installing the Control 3-20 Installing the VA8200 Panel Link Module The VA8200 Panel Link Module (PLM) connects to the keypad (ECP) terminals on the VISTA-128BP/VISTA- 250BP and also connects to other PLMs via the RS-485 bus (3-wire twisted cable run). Figure 3-27 is a block diagram of a panel linking setup using three control panels. UL Panel Linking is not permitted in UL installations. CONTROLPANEL CONSOLEPLM CONTROLPANEL CONSOLE PLM CONTROLPANEL CONSOLE PLM EC P EC P EC P RS-485 PLG-001-V0 Figure 3-27: Panel Linking Block Diagram ECP Wire Run Limitations Determine wire gauge by referring to the table below. Wire Run Length Table Wire Gauge Length #22 gauge 450 feet #20 gauge 700 feet #18 gauge 1100 feet #16 gauge 1750 feet • The length of the ECP wire runs combined must not exceed 2000 feet when unshielded cable is used (1000 feet if unshielded cable is run in conduit or if shielded cable is used). • If more than one ECP device is wired to a single run, then the above maximum lengths must be divided by the number of devices on the run (e.g., the maximum length is 225 feet if two keypads are wired on a #22 gauge run). RS-485 Bus Wire Run Limitations The RS-485 bus from the first Panel Linking Module to the last Panel Linking Module cannot exceed 4000 feet, using 16-AWG twisted-pair cable. The recommended form of wiring is to daisy chain the connection from one unit to another. If several buildings are to be connected, the RS-485 bus should form a continuous path from one building to the next. Avoid wiring units in a star configuration, where multiple branches are formed. Star configurations create loading and capacitance problems that are complex, and become difficult to troubleshoot. Mounting and Wiring the Panel Link Module • The PLM will not operate until the device is enabled in the control’s Device Programming in #93 Menu Mode. • Do not mount the PLM on the cabinet door or attempt to attach it to the PC board. To mount and wire the Panel Link Module, refer to Figure 3-28 and perform the following steps: Step Action 1 Remove all power from the control panel before making any wiring connections. 2 Mount the module in the control cabinet if space is available or, adjacent to the cabinet, using 2-faced adhesive tape. 3 Set the PLM’s DIP switches for a device address between 01 and 30. See the module’s instructions for the DIP switch table. Do not use an address being used by another device (keypads, RF receivers, etc.). 4 Connect the 12V (+) and (–) and data-out and data-in connections from the PLM to the control’s keypads terminals (6, 7, 8, and 9), respectively. 5 Connect the 3-wire RS-485 cable between each PLM. Recommended wiring is to bring the wires “in” from one module (or control panel) to terminals 5 (+), 6 (-), and 7 (G) and “out” to the next module from terminals TB1-8 (+), 9 (-), and 10 (G). +_ G +_ G + _ 1 2 3 4 5 6 7 8 PLG-002-V0 RS-485 RS-485 EOL JUMPER PINS PIEZO SOUNDER TAMPER REED SWITCH DIP SWITCH ECP IN ECP OUT Figure 3-28: VA8200 Panel Link Module Wiring VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-22 Long Range Radio Connected to the J7 Triggers These triggers may be used to trip auxiliary alarm signaling equipment such as ADEMCO’s 7720, 7720ULF, and 7920SE Long Range Radios. The triggers are common to all partitions and must be enabled for each partition (field 2✳20). The fire and burglary/audible panic alarm triggers are normally LOW and go HIGH until a User Code + OFF is entered in all enabled partition(s) that display these conditions. The silent panic/duress trigger latches HIGH, except for duress, which is momentary. Refer to the installation instructions that accompany your radio for the connections to the control panel. Long Range Radio Connected to the ECP The control can support an ECP Long Range Radio (LRR) (7820, 7835C, 7845C and 7845i are supported) that connects to control panel’s keypad terminals. All messages programmed for transmission via the phone lines may also be sent via the LRR. These messages are transmitted in Contact ID format regardless of the format programmed for the control in fields 45 and 47. We recommend that, if possible, you use Contact ID for the main dialer. If Contact ID is not used, certain types of reports are not sent. Operation The VISTA-128BP/VISTA-250BP features Dynamic Signaling Delay and Dynamic Signaling Priority message reporting when Long Range Radio is used. These options are accessed through data fields ✱56 and ✱57, respectively. The Dynamic Signaling feature is designed to reduce the number of redundant reports sent to the central station. The feature is described as follows: Dynamic Signaling Delay (Field ✱56) Select the time the panel should wait for acknowledgment from the first reporting destination before it attempts to send a report to the second destination. Delays can be selected from 0 to 225 seconds, in 15-second increments. Dynamic Signaling Priority (Field ✱57) Select the initial reporting destination for reports, Primary Dialer (0) or Long Range Radio (1). The chart below provides an explanation of how the Dynamic Signaling feature functions. If Priority (✱57) is… And message is… Then… Acknowledged before delay expires Report is removed from queue and no message is sent to LRR. Primary Phone No. ("0") Not acknowledged before delay expires Report is sent to both the Primary Phone No. and LRR. Long Range Radio ("1") Acknowledged before delay expires Report is removed from queue and no message is sent to Primary Phone No. Not acknowledged before delay expires Report is sent to both the Primary Phone No. and LRR. Additional LRR reporting options are defined by selecting the events for each subscriber ID in fields 58 and 59. The reporting events are Alarms, Troubles, Bypasses, Openings/Closing, System Events, and Test. Also, within an enabled category, the specific event must be enabled for dialer reporting. If, for instance, zone 10 is enabled to report, but zone 11 is not, zone 10 will report via the LRR, but Zone 11 will not. Reports are transmitted from the VISTA- 128BP/VISTA-250BP to the LRR on a “first in/first out” basis. If events occur at the same time, they are transmitted in order of priority. The priority from most to least important is : Fire Alarms, Panic Alarms, Burglary Alarms, Fire Troubles, Non-Fire Troubles, Bypasses, Openings/Closings, Test messages, and all other types of reports. There are two subscriber IDs programmed into the LRR: primary and secondary. These correspond to the two subscriber ID’s programmed into the control for each partition. If a subscriber ID for a partition is not programmed (disabling reports to that central station), the events enabled for the corresponding subscriber ID in the LRR will not be transmitted. If the event is to be reported to both phone numbers (dual reporting), then reporting through the LRR will be done in an alternating sequence. The first event in the queue is transmitted to both the primary and the secondary radio central stations before transmitting the second event. If split reporting is selected for the VISTA- 128BP/VISTA-250BP, then the LRR will send the appropriate reports to the primary and secondary central stations. Installing the ECP LRR To install the ECP LRR, perform the following steps: Step Action 1 Mount the radio according to the instructions that accompany the radio. Section 3 - Installing the Control 3-23 2 Connect the data in/out terminals and voltage input terminals of the radio to the control’s keypad connection points, terminals 6, 7, 8, and 9. See Figure 3-29. RED BLACK GREEN YELLOW CONTROL TERMINALS 7 8 9 6 ECP RADIO Figure 3-29: Wiring Long Range Radio to Keypad Terminals Supervision The data lines between the control and the LRR, as well as certain functions in the radio, can be supervised. If communication is lost or a trouble condition occurs, both the LRR and the control’s dialer can be programmed to send a Trouble message to the central station. NOTE: For complete information, see the Installation Instructions that accompany the radio. Trouble Messages The following messages are displayed on the 6139/6160 when a problem exists on the Long Range Radio: 1. “LRR Battery”: The battery connected to the radio is low. 2. “PLL out of Lock”: The radio has an internal fault and cannot transmit any messages. 3. “Early Power Detect”: RF power is detected without a valid transmission. 4. “Power Unattained”: Full RF power was never attained. 5. “Frwd. Power Loss”: RF power was not sustained throughout the transmission. 6. “Antenna Fault”: A problem with the antenna has been detected. 7. “LRR CRC is bad”: The radio’s EEPROM is corrupt (the internal CRC is bad). NOTES: Items 2 and 3 require factory service. Items 4 and 5 could be the result of a bad or low battery. If the item 6 message appears, check the antenna, connection and cable; if they are secure, factory service is required. All these messages are displayed in conjunction with the “CHECK 8xx” message, which indicates a trouble on the address to which the LRR unit is programmed in the control. All of these events except Antenna Fault are sent to the event log and reported to the central station using Contact ID Event Code 333 (expansion device trouble). Antenna Fault uses Event Code 357. If the tamper is tripped on the LRR, it uses Event Code 341 (expansion device tamper). Installing the Alpha Pager Module The VA8201 Alpha Pager Module (APM) is used for the transmission of alphanumeric messages to a user- subscribed Paging Service. The APM can be programmed to send the information to up to 8 different paging services. In addition, the module can direct the event log reports to a parallel or serial printer and can interface the control to a computer equipped with Home Automation software. UL The Alpha Pager Module is not permitted in UL installations. The types of events (messages) the pager can transmit are divided into 5 categories: alarms, troubles, bypasses, openings/closings, and system. The options for each paging service are: • Paging service phone number • Format (numeric, alphanumeric) • Two Delay Times (numeric format only): the time between dialing and transmitting of pager ID and the time between pager ID and event information • Pager ID number (if necessary) • Partition(s) (which partitions the events are transmitted for) • Types of messages (events) sent. Must be programmed for the pager to work. The APM hangs up between each message. Multiple messages are sent in the order received. If the APM cannot make contact with the paging service, it retries up to 10 times. • The APM is only required for alphanumeric format. The system sends numeric format messages directly. • When using the APM, field ✳14 must be programmed for RS232 input (1). Zone 9 can longer be used as a protection zone. • The APM transmits alphanumeric messages using the TAP protocol. You must check with the paging service to ensure that they are using the TAP protocol Rev. 1.8 or higher. VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-24 Paging Service Advisory If you are setting up the software for the first time, contact your paging service provider for the following two pieces of information: • The exact access number to be used with each receiving device • The correct PIN number for each receiving device. Pager Formats The system supports pager formats numeric and alphanumeric. Numeric Format SSSS P EEE ZZ, where: SSSS The partition’s 4-digit subscriber number (field ✳32) P Partition number EEE 3-digit event code ZZZ 3-digit zone or user number NOTE: If any of the digits for the subscriber number are hex digits (A, B, C, D, E, F), they will be replaced with 0, 1, 2, 3, 4, 5, respectively, on the pager display. Numeric Format Event Codes Event Code Alarm 333 Trouble 555 Open 444 Close 777 Other 000 Alphanumeric PP Date Time EA ZZZ SSSS AD Where: PP Partition number (e.g., P1) Date Date the event occurred (e.g., 03/15/00) Time Time the event occurred (e.g., 01:16AM) EA Event alpha descriptor (see APPENDIX D) ZZZ Zone or user number SSSS The partition’s 4-digit subscriber number (in field ✳32) AD The zone’s programmed alpha descriptor ✳ ✳ If the event is an arming or disarming, a 6- character descriptor can be sent for the user, if programmed, instead of the user number. The descriptor can be programmed only via the Compass Downloader. The installer code has a default of INSTLR and user number 002 has a default of MASTER for the 6-character descriptor. Mounting the Alpha Pager Module The Alpha Pager Module (APM) may be mounted in the control cabinet if space is available or, if this is not possible, on the side of the cabinet or adjacent to it. Do not mount the Alpha Pager Module on the cabinet door or attempt to attach it to the PC board. To mount the Alpha Pager Module, perform the following steps: Step Action 1 If you are mounting the Alpha Pager Module inside the control cabinet, attach it to the cabinet’s interior surface with 2-faced adhesive tape. 2 If you are mounting the Alpha Pager Module outside the cabinet, use the bracket interface (Ademco Part Number K5350). Wiring the Alpha Pager Module The Alpha Pager Module connects via the 4142TR cable to the J8 connector on the VISTA-128BP/VISTA- 250BP. To wire the Alpha Pager Module, refer to Figure 3-30 and perform the following steps: Step Action 1 Connect the 4142TR to J8 on the control. 2 Connect the Brown wire of 4142TR to the Orange wire of the APM. 3 Connect the Green wire of the APM to TB1- 23 of the control panel. 4 Connect the Red and Black wires of the APM to terminals 6 and 7 (auxiliary power (+) and (-), respectively) of the control. 5 Connect the APM RJ11 connector labeled LINE to the handset terminals on the control panel (terminals 26 and 27). 6 Connect the handset side of telephone line to APM RJ11 connector labeled PHONE (Optional) (Brown and Gray wires of Phone Cord). 7 If you are using a parallel or serial printer, connect the printer according to the instructions accompanying the APM. • The serial printer must be configured for a baud rate of 1200, eight data bits, no parity, and one stop bit. (8/N/1). • The serial printer and Home Automation cannot be used on the same system. If you want to use a printer and Home Automation, you must use a parallel printer. Section 3 - Installing the Control 3-25 VA8201 ALPHA PAGER MODULE AUX PWR. PARALLEL PRINTER PARALLEL OUTPUT SERIAL OUTPUT DATA/ POWER TO PHONE TO LINE EARTH GROUND HOME AUTOMATION COMPUTER TIP RI N G RJ31X JACK TIP RING INCOMING TELCO LINE ANSWERING MACHINE CALLER ID UNIT PREMISES CALLER ID UNIT, ANSWERING MACHINE, AND PHONES RE D BROWN GRAY GR E E N RED BLACK GREEN RED BLACK GREEN AUX GND. 62627282930237 TIP RING HANDSET TIP RING INCOMING PHONE CORD (ZONE 9)BROWN WIRE FROM 4142 TR TRIGGER CABLE SPLICE VA8201-SOC-V1 1 2 3 4 5 6 7 8 9 J8 BR O W N ORANGE CONTROL PANEL NOTE WHEN USING THE VA8201, ZONE 9 CAN NO LONGER BE USED AS A PROTECTION ZONE. Figure 3-30: Wiring the Alpha Pager Module Access Control Using VistaKey The VistaKey is a single-door access control module that, when connected to the alarm system, provides access control to the protected premises. The VISTA- 128BP supports up to 8 modules, the VISTA-250BP supports up to 15 VistaKey modules (15 access points). DO NOT USE BOTH the VistaKey and a PassPoint Access Control System on the same alarm panel. UL The VistaKey module contains three zones. These zones should ONLY be used for access control functions in UL installations. THESE INPUT ZONES ARE NOT TO BE USED FOR FIRE AND BURGLARY APPLICATIONS IN UL INSTALLATIONS. VistaKey Features • Each VistaKey communicates with the VISTA- 128BP/VISTA-250BP via the V-Plex polling loop. • In the event local power to the VistaKey is lost, the VistaKey module provides backup monitoring of the access point door via a built-in V-Plex device that is powered solely from the polling loop. It is programmed as a new type of V-Plex device as part of the control’s V-Plex Device Programming. A serial number label is affixed to the VistaKey module for manual entry of its serial number. • The VistaKey supports up to 500 cardholders. • The addition and removal of VistaKey modules from the system is easily accomplished via the VISTA-128BP/VISTA-250BP keypad. • All configurable options for each VistaKey are accomplished via software, firmware, and nonvolatile memory, eliminating the need for PC board jumpers. The access point zone number (1- 15) is set via a user-friendly, 16-position rotary switch. • Each VistaKey provides one open-collector output trigger (sink 12mA @ 12VDC). Mounting and Wiring the VistaKey For detailed instructions on how to install and program the VistaKey, refer the Installation and Setup Guide that accompanies the VistaKey- SK. To mount and wire the VistaKey module, perform the following steps: Step Action 1 Mount the VistaKey, door strike or mag lock, and card reader. 2 Mount the door status monitor (DSM) and/or request-to-exit (RTE) devices. 3 Using Figure 3-31 as a reference, connect the card reader interface cable to TB3, making the +5V or +12V connection last. VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-26 Step Action 4 Connect the leads to TB1 in the following order: a. All ground leads to terminals 2, 5, and 9. b. The DSM, (optional) RTE, and General Purpose leads to terminals 6, 7, and 8, respectively. c. Door strike (or mag lock) lead to terminal 10. d. Local +12V or +24V supply lead to terminal 1. e. Local +12V or +24V supply lead to the N/C relay terminal 11 (if a mag lock is being used), OR to the N/O relay terminal 10 (if a door strike is being used). 5 Connect the (–) polling loop and (+) polling loop leads (from the VISTA-128BP/VISTA- 250BP) to terminals 4 and 3, respectively. 6 Set the Address Select switch to the desired access door number (1-15). 7 Repeat steps 1 through 6 for each VistaKey being installed. Connecting the Card Reader Lead from Reader Lead Color To VistaKey TB3 Terminal # Green LED Orange 1 Ground* Black 2 DATA 1 (Clock) White 3 DATA 0 (Data) Green 4 +5VDC† Red† 6 +12VDC† Red† 7 * TB-3 Terminal 5 is also a ground and may be used instead of terminal 2. Terminals 2 and 5 are a common ground. † Connect to +5VDC OR +12VDC per reader manufacturer’s specification. +WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM. POLE Door Strike/Mag Coil DATA 1 (WHITE) DATA 0 (GREEN) NOTE 1: USE UL LISTED ENERGY CABLE FOR ALL CONNECTIONS. NOTE 2: VISTAKEY TB3 TERMINAL 5 IS A GROUND AND MAY BE USED INSTEAD OF TB3 TERMINAL 2. TB3 TERMINALS 2 AND 5 ARE A COMMON GROUND. NOTE 3: WHEN USING TRIGGER TO TURN ON AN LED OR BUZZER, RETURN HIGH SIDE OF LED OR BUZZER TO TB3 TERMINAL 7. TRIGGER RATING IS 15mA AT 12VDC. +5V GND TRIGGER (SEE NOTE 3) +12V (RED) ZONE C (General) ZONE A (DSM) ZONE B (RTE) POLLING LOOP - 14V MAX (12V @ 85-160mA Nominal) POLLING LOOP + GND GND GND N/O DOOR STRIKE POWER N/C MAG COIL POWER 2 3 4 5 6 7 8 111223456789101 RELAY CONTACT RATINGS: 3A @ 28VDC MAX. (RESISTIVE LOAD)TB 1 TB 3 1 READER INTERFACE CABLE GND (BLACK) RDR LED (ORANGE) TO ALARM SYSTEM CONTROL PANEL POLLING LOOP TERMINALS. NO CONNECTION VISTAKEY THIS DEVICE COMPLIES WITH PART 15 CLASS A LIMITS OF FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) IT MAY NOT CAUSE HARMFUL INTERFERENCE. (2) IT MUST ACCEPT ANY INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. K1 DOOR CONTROL RELAY FOR ADDITIONAL RATINGS AND SPECIFICATIONS, REFER TO INSTALLATION INSTRUCTION FOR THE VISTAKEY-SK. THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION'S STANDARDS 70 & 74 (NATIONAL FIRE PROTECTION ASSOC., BATTERYMARCH PARK, QUINCY, MA. 02269). PRINTED INFORMATION DESCRIBING PROPER MAINTENANCE, EVACUATION PLANNING AND REPAIR SERVICE IS TO BE PROVIDED WITH THIS EQUIPMENT. TO T B 1 , 1 1 O R 1 2 + 12 VDC TO ONLY ONE OF THESE INPUTS. (FROM TB1-1) Figure 3-31: Wiring the VistaKey Access Control Using the PassPoint Access Control System The VISTA-128BP/VISTA-250BP interfaces with the PassPoint ACS via the VISTA Gateway Module (VGM). The VGM is connected between the ECP bus (keypad terminals) of the control and the network bus of the PassPoint ACS. The control sends the VGM its status information, event log entries, and entry/exit requests (inputs programmed with response type Access Point) from keypads, hardwired zones, and RF transmitters. Section 3 - Installing the Control 3-27 The VGM then reformats and retransmits this information to the Main Logic Board, (MLB) on the PassPoint ACS network bus. UL Interfacing the VISTA-128BP/VISTA-250BP with the PassPoint Access Control System via the VISTA Gateway Module is not permissible for UL installations. Wiring the VISTA Gateway Module The VISTA Gateway Module is connected between the ECP bus (VISTA-128BP/VISTA-250BP keypad terminals) and the network bus of the PassPoint Access Control System. See Figure 3-32 for the proper wiring connections. }ECHELON NETWORK (PASSPOINT ACS) YELLOW RED BLACK PROM C TRANSFORMER 4-PIN KEYPAD PLUG }TO CONTROL’S KEYPAD TERMINALS GREEN Figure 3-32: Wiring the VISTA Gateway Module Installing a 4100SM The 4100SM is used to print event log reports to a serial printer or to interface the control with a computer equipped with Home Automation software. When using the 4100SM, the system can interface with either a serial printer or Home Automation. It cannot do both. NOTE: See SECTION 4: Programming for the programming details when using the 4100SM. Printer/Computer Configurations Configure the serial printer or the Home Automation computer as follows: • 8 data bits, no parity, 1 stop bit • 1200 baud Connecting the 4100SM to a Serial Printer To connect a serial printer using the 4100SM, refer to Figure 3-33and perform the following steps: Step Action 1 Connect terminal 1 on the 4100SM to the Violet wire on the 4142TR cable. 2 Connect terminal 6 on the 4100SM to the Brown wire on the 4142TR cable. 3 Connect the 4142TR cable to J8 on the control. 4 Connect terminals 8 and 7 of the 4100SM to terminals 6 and 7 (aux. power (+) and (-)), respectively of the control. 5 Connect the UL EDP Listed serial printer to the 4100SM Interface Module. The 4100SM Module is supplied with a 10- foot RS232 cable. A longer cable can be used if the VISTA-128BP/VISTA-250BP is separated from the serial printer by more than 10 feet, but the total cable length should be less than 50 feet. 123456789 NU J8 CONNECTOR VIO L E T GR E Y YE L L O W RE D GR E E N BR O W N BL U E BL A C K IN 2 IN 3 GROUND OUT 5 OUT 6 GROUND GROUND PRI N T E R D T R 4142TR CABLE (SUPPLIED WITH 4100SM) 8 7 6 5 4 3 2 1 4100SM SERIAL MODULE + PWR - (GND) RXD not used not used TXD not used DTR BLUE WHITE To TB6 Aux. Power (+) (25mA current draw) To TB7 Aux. Power (-) USE GENDER CHANGER SUPPLIED WITH 4100SM IF PRINTER HAS DB25 MALE CONNECTOR 3MCableSupplied with 4100SM SERIAL PRINTER SET FOR: 8 DATA BITS EVEN PARITY STOP BIT300/1200 BAUD 4100SM JUMPERS (CUT TO SET RESPECTIVE SIGNAL FLOATING) COLORFUNCTIONPIN # RED BLUE WHITE CD CTS DSR 8 5 6 RED 41 0 0 S M - 0 1 1 - V 0 Figure 3-33: 4100SM Using a Serial Printer NOTE: See the 4100SM Installation Instructions for details concerning the serial printer operation. Connecting the 4100SM to a Home Automation Computer To connect the computer to the 4100SM, refer to Figure 3-34 and perform the following steps: Step Action 1 Connect terminal 23 on the control panel to terminal 3 on the 4100SM. 2 Connect terminal 6 on the 4100SM to the Brown wire on the 4142TR cable. 3 Connect the 4142TR cable to J8 on the control. 4 Connect terminals 8 and 7 of the 4100SM to terminals 6 and 7 (aux. power (+) and (-)), respectively of the control. 5 Connect the Home Automation computer VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-28 serial port to the 4100SM Interface Module. 123456789 NU J8 CONNECTOR VIO L E T GR E Y YE L L O W RE D GR E E N BR O W N BL U E BL A C K IN 2 IN 3 GROUND OUT 5 OUT 6 GROUND GROUND PRINTER DTR 4142TR CABLE (SUPPLIED WITH 4100SM) 8 7 6 5 4 3 2 1 4100SM SERIAL MODULE + PWR - (GND) RXD not used not used TXD not used DTR BLUE WHITE To TB6 Aux. Power (+) (25mA current draw) To Serial Port of Computer To Terminal TB23 (Zone 9 [+]) To TB7 Aux. Power (-) RED 4100SM-013-V0 Figure 3-34: 4100SM Using Home Automation NOTE: See the Home Automation software instructions for details concerning its operation. Installing the 4285/4286 VIP Module The 4285/4286 VIP Module is an add-on accessory that permits the user to access the security system (and relays) via a TouchTone telephone. This may be done either from the premises or by calling the premises from a remote location. Only one VIP Module can be used in a security system. This module must be enabled as Device Address 4 in the Device Programming in #93 Menu Mode, and must be assigned to a partition. UL The 4285/4286 VIP Module is not permitted in UL installations. Detailed operating instructions for phone access to the security system are provided with the VIP Module. The 4285/4286 VIP Module features: • Allows the user to receive synthesized voice messages over the phone regarding the status of the security system. • Allows the user to arm and disarm the security system and perform most other commands using the telephone keypad. • Allows the user to control relays using the telephone keypad. • Provides voice annunciation over the phone to confirm any command that is entered. • Announces many of the same words that would normally be displayed on an alpha keypad under the same system conditions. Refer to the words in bold on the Alpha Vocabulary list found in the #93 Menu Mode in the Programming Guide. • Can be supervised for connection to control panel (annunciated and reported as Zone 804). The 4285/4286 is wired between the control panel and the premises’ handset(s) (see Figure 3-35). It listens for TouchTones on the phone line and reports them to the control panel. During on-premises phone access, it powers the premises phones. During off-premises phone access, it seizes the line from the premises phones and any answering machines. • The VIP module will not operate until the device address (04) is enabled in the control’s Device Programming in #93 Menu Mode. • Do not mount the VIP Module on the cabinet door or attempt to attach it to the PC board. To install the VIP module, perform the following steps: Step Action 1 Mount the module in the control cabinet if space is available or, if this is not possible, on the side of the cabinet or adjacent to it. If you mount the VIP Module inside the control cabinet, attach it to the cabinet’s interior surface with 2-faced adhesive tape. You may leave the module’s cover off if it is mounted within the cabinet. If you mount the module outside the cabinet, use the screw holes at the rear to mount horizontally or vertically (2-faced adhesive tape may be used, if preferred). 2 Affix the 4285/4286 connections label (supplied separately) to the inside of the VIP Module’s cover, if the cover is used. Otherwise, affix the label to the inside of the Section 3 - Installing the Control 3-29 control cabinet’s door. 3 Make 12V (+) and (–) and data-in and data- out connections from the VIP Module to the control, using the connector cable supplied with the VIP Module. These are the same connections as for remote keypads. Step Action Connect the module to the phone line as shown below. See Figure 3-35. 4285/4286 Terminal Connects to direct connect cord: 1. Phone In (Tip) green wire 2. Phone In (Ring) red wire 3. Phone Out (Tip) brown wire 4. Phone Out (Ring) gray wire 5. No Connection 6. Audio Out 1∗ Speaker 7. Audio Out 1∗ Speaker 4 ∗∗∗∗Supported by the 4286 only Use an RJ31X Jack with the phone cable supplied with the control to make connections to the VIP module. Make connections exactly as shown in Figure 3-35. This is essential, even if the system is not connected to a central station. The 4285/4286 will not function if this is not done. • If touch-tones are not present following phone access to the security system via an on-premises phone, try reversing the pair of wires connected to terminals 3 and 4 on the 4285/4286. • If the phone plug is disconnected from the control, the premise’s phones will not operate. YELLOW NOCONNECTION RED BLACK GREEN TO CONTROL PANEL KEYPAD CONNECTIONS KEYED HEADER 12 3 4 5 6 7 NO CONNECTION 4286 VIP MODULE ANSWERING MACHINE PREMISES ANSWERING MACHINE AND PHONES TI P RI N G RJ31X JACK TIP RING INCOMING TELCO LINE CALLER ID UNIT IMPORTANT NOTE FOR EXISTING INSTALLATIONS: EXISTING WIRES CONNECTED TO THE “HANDSET” TERMINALS ON CONTROL MUST BE MOVED FROM THERE TO TERMINALS 3 AND 4 ON THE 4286. U.S.PATENT No.4791658 THIS DEVICE COMPLIES WITH FCC RULES, PART 68 FCC REGISTRATION No.AC3USA-74659-KX-N RINGER EQUIVALENCE:1.0B FOR COMPLETE INFORMATION, SEE INSTALLATION INSTRUCTIONS N6431-3 ACCOMPANYING 4286 VIP MODULE GREY BROWN GR E E N RE D EARTH GROUND TIP RING TIP RING 4500 THERMOSTAT GREENYELLOW HANDSETINCOMING TELCO LINE NOTE: 4286 DEVICE ADDRESS IS FACTORY SET TO “4” SEE SPEAKER NOTE SPEAKER NOTE:IF CONNECTING SINGLE SPEAKER, USE 8-ohm SPEAKER ONLY. IF CONNECTING 2 SPEAKERS, USE 4-ohm or 8-ohm SPEAKERS AND CONNECT IN SERIES. SPEAKER VOLUME CONTROL 4286_wiring-002-V1 Figure 3-35: VIP Module Connections VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-30 Installing the Audio Alarm Verification Module UL Audio Alarm Verification (AAV) is not permitted in UL installations. • 685 Receiver software must be rev. 4.6 or higher. Earlier versions will not hold the phone line connection. • Contact ID code for “Listen-in to Follow” is 606. Contact ID is the only reporting format that will send a “Listen-in to Follow.” • If you are also using a 4285/4286 VIP Module, be sure to follow Figure 3-37 when making connections. The UVS consists of a UVCM and at least one UVST. The UVCM board has a DC power jack and a 34- position terminal block for making connections to a DC power source, UVSTs, telephone lines, music source, or to the 4286 VIP Module; and to a control panel’s voice trigger and bell outputs (if required). Refer Figure 3- 28 for wiring connections. For a detailed explanation of the wiring connections and the functions of the DC power jack and terminal block positions, refer to the installation instructions that accompany the UVS. If the phone plug is disconnected from the control, the premise’s phones will not operate. NOTES: • When the AAV indicates that the audio alarm verification session is completed, all keypad sounds are restored. Sirens are restored if the alarm timeout period has not expired. • As part of its fail-safe software, the control limits all audio alarm verification sessions to 15 minutes. This is because once the session begins, the AAV Module controls the duration. • If a new Fire alarm should occur during a session, the control breaks the phone connection and sends the new Fire Alarm report, then re- triggers the AAV Mode. All other dialer messages triggered during ongoing conversation are held until either the AAV Module signals that it is inactive, or the 15-minute timeout occurs. Section 3 - Installing the Control 3-31 RE D GR E E N RIN G TIPNO T U S E D EA R T H G N D GN D AU X I L I A R Y A U D E N A B L E AU X I L I A R Y A U D I N SP K R 7 SP K R 6 SP K R 5 SP K R 4 SP K R 3 SP K R 2 SP K R 1 GN D GN D +1 2 V D C I N GN D IN S I D E U V S T P W R IN S I D E U V S T P W R OU T S I D E U V S T P W R AL A R M T R I G I N VO I C E R E L A Y P O L E VO I C E R E L A Y N C FA L L I N G V O I C E T R I G RIS I N G V O I C E T R I G NO T U S E D MIC 7 MIC 6 MIC 5 MIC 4 MIC 3 MIC 2 MIC 1 SWITCH BANK 1 SWITCH BANK 2 SWSWITCH BANK 1 1UVST 1 AUX AUDIO, ON = ENABLED 2UVST 2 AUX AUDIO, ON = ENABLED 3UVST 3 AUX AUDIO, ON = ENABLED 4UVST 4 AUX AUDIO, ON = ENABLED 5UVST 5 AUX AUDIO, ON = ENABLED 6UVST 6, ON = OUTSIDE, OFF = INSIDE 7UVST 7, ON = OUTSIDE, OFF = INSIDE 8VOICE TRIGGER, ON = IMMED, OFF = CALLBACK SWSWITCH BANK 2 1FUTURE USE, SET TO ON 2FUTURE USE, SET TO ON 3TELEPHONE RING, ON = ENABLED 4END USER VOICE, ON = DISABLED 5FUTURE USE, SET TO ON 6CS CODE LEARN, ON = DISABLED 7USER CODE LEARN, ON = DISABLED 8FUTURE USE, SET TO ON SHIPPED WITH ALL SWITCHES IN "ON" POSITION. ON ON AUXILIARY AUDIO LEVEL ADJUSTMENT TRIM POT INCOMING RING INCOMING TIP HANDSET RING HANDSET TIP CONTROL PANEL BE L L O U T P U T GN D AU X P W R ( 1 2 V D C ) 2- W A Y V O I C E T R I G G E R (S E E N O T E 3 ) (O P T I O N A L ; N O T E 5 ) (N O T E 2 ) (N O T E 2 ) 4286 VIP MODULE 12 3 4 5 6 7 12 3 4 KEYED HEADER SPEAKER VOLUMECONTROL OPTIONAL (NOTE 4) UV S T P W R GN D MIC SP K R SPEAKER VOLUME TRIM POT TYPICAL 1 OF 7 AUDIO OUT GND MUSIC SOURCE OPTIONAL (NOTE 4) PREMISES ANSWERING MACHINE AND PHONE (S) ANSWERING MACHINE P3 UVST VOLUME CONTROL DIAL TIPRIN G TIP RING 1234567812345678 NOTE 1: CONNECT TO PROPER EARTH GROUND. NOTE 2: POWER MAY ALSO BE SUPPLIED BY A LISTED CLASS 2 POWER SUPPLY RATED 12VDC, MIN 600mA CONNECTED TO THE UVCM +12VDC IN AND GND TERMINALS. NOTE 3: SOME CONTROL PANELS USE BUILT-IN TRIGGER AND SOME USE 4204 RELAY MODULE. REFER TO AAV SECTION OF CONTROL PANEL INSTALLATION AND SETUP GUIDE FOR CONNECTION. NOTE 4: EITHER MUSIC SOURCE OR 4286 VIP MODULE CAN BE USED BUT NOT AT THE SAME TIME. NOTE 5: DO NOT CONNECT IF 4286 VIP MODULE IS USED. 1234567891011121314151617181920212223242526272829 3031323334 SE L E C T AP P R O P R I A T E IN P U T RJ31X JACKPLUG DIRECT CONNECT CORD NOTE 1 UVCM AND UVST SUMMARY OF CONNECTIONS P2 P1 P7 FOR COMPLETE INFORMATION, SEE 4286 VIP MODULE INSTRUCTIONS. WARNING: TO PREVENT RISK OF ELECTRICAL SHOCK, DISCONNECT TELCO JACK BEFORE SERVICING THIS PANEL. COMPLIES WITH FCC RULES, PART 68FCC REGISTRATION NO. AC3 USA-40133-SP-TRINGER EQUIVALENCE: 1.0B THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFULINTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. 1 2 3 4 Refer to UVS Installation and Setup Guide K4214 for complete information GR A Y BR O W N UV C M _ U V S T - S O C - V 1 INCOMINGTELCO LINES ALTERNATE +12 VDC IN FOR PLUG-IN WALL PACK (SEE NOTE 2) Figure 3-36: UVS Connections to the Control Panel Installing TeleSmart The TeleSmart system provides a telephone interface and message center for an ADEMCO security system. It has the following features: • 4 unique mailboxes for storing messages • 6 user access codes • Security system interface • Memo feature for leaving messages for other users • Caller ID capabilities for up to 25 phone numbers • Memory (speed) dialing for up to 15 phone numbers • Repeat dialing (automatically redials busy numbers) • Last number redial • Call screening (with and without Caller ID) • Privacy (turns off the ringer) • Remote access of TeleSmart and security system VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-32 NOTE: The keypad connected to the TeleSmart module must be the 6139T. UL TeleSmart is not permitted in UL installations. Mounting the Telesmart Module The TeleSmart Module should be mounted in the security system’s control cabinet if space is available, or within a grounded metal enclosure to provide proper ESD protection. Mounting Inside the Control’s Cabinet: Use double-sided tape to attach the module to the interior surface of the cabinet, or hang it on two screws. Do not mount it on the cabinet door or attach it to the control’s PC board. Mounting Outside the Cabinet: Use the screw holes at the rear of the module. Wires can be brought out from the side or back (use the round breakout on the back). Affix the Summary of Connections label to the module’s inside cover or to the inside of the cabinet door. Wiring Connections Before making connections, power down the control panel. To wire the TeleSmart, perform the following steps: Step Action 1 Use a standard RJ31X phone jack (CA38A in Canada) and direct-connect cord. Connect the direct-connect cord’s red and green wires to the control’s incoming phone line terminals as described in the control’s instructions. (Figure 3-37) 2 Connect the direct-connect cord’s brown and gray wires to TeleSmart’s “Home Phones” terminals, disconnecting them from the control’s premises phone terminals, if previously connected. 3 Connect the control’s local phone TIP and RING terminals to TeleSmart’s “From Control” terminals (wires not supplied). 4 Connect an 8-Ohm speaker to TeleSmart’s speaker terminals. (Figure 3-38) 5 Disconnect those keypads intended to be used with TeleSmart from the control’s terminals, if previously connected. Step Action Connect keypad wiring as shown in (Figure 3-39) (see the chart below for the maximum wire run length for wire gauge you are using). NOTE: Run audio cable in separate 2- conductor twisted-pair cable (22AWG recommended). This cable should be kept at least 6 inches from other types of cables carrying potentially interfering signals, such as AC power, telephone, and polling loop cables. WIRE RUN LENGTHS Gauge 150mA 300mA 500mA 600mA 750mA 22 AWG 160ft 80ft 50ft 42ft 32ft 20 AWG 260mA 130mA 80mA 67mA 52mA 18 AWG 410mA 220mA 130mA 115mA 83mA 16 AWG 650mA 330mA 200mA 170mA 130mA 6 7 Set the keypad address, tamper option, and playback volume setting by pressing and holding the [1] and [3] keys at the same time for 3 seconds, then follows the prompts. You must press these keys within 60 seconds of power-up to set the address and/or tamper option; you can set the volume at any time after power-up. Refer to the instructions included with the keypad for additional details. You must set TeleSmart keypads to addresses 0-7 only. 8 TeleSmart Plus is powered from the control’s +12VDC keypad terminal. Connect the control’s keypad terminals to the TeleSmart Plus Control terminals as shown. (Figure 3- 41) IMPORTANT: You must program the TeleSmart module as device address 24 when programming the control. 9 This connection is used to drive the TeleSmart internal clock. Connect either terminal of the control’s AC input terminals to the TeleSmart RTC terminal. (Figure 3- 40) 10 Connect the TeleSmart ground terminal to a good earth ground. (Figure 3-40) Section 3 - Installing the Control 3-33 TYPICAL CONTROL’S PHONE TERMINALS LOCAL INCOMING RING TIP RING TIP RED GREEN BROWN GREY DIRECT CONNECT CORD 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 RJ31X 1 2 3 45 6 7 8 RING TIP INCOMING PHONE LINE TO PREMISES PHONES GREENRED GREY BROWN RING TIP FROM CONTROL HOME PHONES phon_conn-V0 Figure 3-37: TeleSmart Phone Connections NOTE: If the system hangs up the phone line when calling in from a remote location, check the phone connection terminals (Term. 17/18 = from control; Term. 15/16 = to house phones). 8 ohm Speaker 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 AUX SPEAKER Figure 3-38: TeleSmart Speaker Connection VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-34 IN OUT GRN (DATA IN) RED (+12VDC) BLACK (–) YEL (DATA OUT) USE OUTER WIRES OF AUDIO CABLE AUDIO IN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 KEYPADS KEYPAD AUDIO BUS ® 1 OFF 4 MAX 7INSTANT READY 2AWAY 5TEST 8CODE 0 3 STAY 6BYPASS 9CHIME # ARMED READY MESSAGE Figure 3-39: Keypad Connections REAL-TIME CLOCK (RTC) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 EARTH GROUND TYPICAL CONTROL'S AC TERMINALS Figure 3-40: RTC and Ground Connections 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 YEL (DATA OUT) RED (+12VDC) GRN (DATA IN) BLACK (-) GND TO CONTROL'S KEYPAD TERMINALS Figure 3-41: TeleSmart to Control Connections Section 3 - Installing the Control 3-35 Connecting the Transformer This product uses the 1361 transformer (1361CN in Canada). If you are using X-10 devices, the 1361X10 transformer interface must be used instead of the regular 1361 transformer. The 1361X10 supplies the control panel with AC, and also sends control pulses through the premises’ electrical system to control the X-10 devices. UL Use 1361CN Transformer in Canadian installations. Power Limiting Outputs All outputs are power-limited as per UL985/UL1023. The following table shows the maximum current that may be drawn from each output. Output Maximum Current Draw Auxiliary Power 750mA Polling Loop 128mA Alarm Output 1.7A For Household Fire or Combination Household Fire/Burglary Installation: The total current drawn from the auxiliary power, the polling loop, and the alarm output combined must not exceed 750mA to comply with the battery independence requirements in UL985. For Household Burglary-Only Installations: The total current drawn from the alarm output may be up to 1.7A. A battery must be installed to supply the current of the combined auxiliary power, polling loop, and alarm output in excess of 750mA. Failure to observe the polling loop current rating will cause polling loop malfunction. Failure to observe the auxiliary power current rating will result in a battery that does not charge properly or possibly a tripped circuit breaker. To connect the transformer to the control, perform the following steps: Step Action 1 Connect all installed devices to the control. 2 Wire the 1361 Transformer (1361CN in Canada) to the panel (before connecting the battery) as shown in Figure 3-42, or wire the 1361X10 Transformer as shown in Figure 3-43 (if using X-10 devices). 3 Plug the transformer into a 24-hour, uninterrupted, 120VAC, 60Hz outlet. After a few seconds, the keypad display appears. NO C O N N E C T I O N TRANSFORMER 16.5VAC, 40VA ADEMCO No.1361 or 1361X10, if X-10 DEVICES WILL BE USED. Connect to24hr. sourceof AC mains 123 RE D ( + ) BL K ( - ) Connect to 12VDC, 4AH or 12VDC, 7AH GEL CELL BATTERY CHARGINGVOLTAGE13.7VDC NOTE: WHEN POWERING UP THE PANEL, PLUG THE TRANSFORMER IN BEFORE CONNECTING THE BATTERY. BATTERYTABSPRIMARY POWER Supplied by a transformer which is rated at 16.5VAC, 40VA. Caution must be taken when wiring this transformer to the panel to guard against blowing the fuse inside the transformer (non-replaceable). pw r _ b a t _ c o n n - 0 0 1 - V 1 Figure 3-42: 1361 Transformer and Battery Connections 123456789 BL A C K BL U E BR O W N GR E E N RE D WH I T E YE L L O W GR A Y VIO L E T 4142TR CABLE X10 TRANSFORMER/INTERFACE TERMINALS ON CONTROL BOARD 1361X10-001-V0 J8 CONNECTOR Figure 3-43: 1361X10 Transformer Connections VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-36 Panel Earth Ground Connections In order for the lightning transient protective devices in this product to be effective, the designated earth ground terminal (terminal 30) must be terminated in a good earth ground. Recommended wire gauge for the ground connection is #16 AWG, run no farther than 30 feet. The following are examples of good earth grounds available at most installations: • Metal Cold Water Pipe: Use a noncorrosive metal strap (copper is recommended) firmly secured to the pipe to which the ground lead is electrically connected and secured. • AC Power Outlet Ground: Available from 3- prong, 120VAC, power outlets only. To test the integrity of the ground terminal, use a three-wire circuit tester with neon lamp indicators, such as the UL-Listed Ideal Model 61-035, or equivalent, available at most electrical supply stores. The panel requires the earth ground connection for its lightning transient protection devices. Determining the Control’s Power Supply Load Use the tables that follow to calculate the total current for the Auxiliary Power, the Alarm Output, and the Polling Loop. In each table, multiply each device’s standby and/or alarm current by the number of units used. 1. In Table 1, enter devices used on the polling loop. Calculate total current draw on the polling loop. Table 1: Total Polling Loop Current Draw Polling Loop Device Current # of Units Total Polling Loop Subtotal (terminals 24 & 25 – 128mA) ✳ ✳ The total current cannot exceed 128mA. If total load exceeds 128mA, then a 4297 Loop Extender Module can be used. Note that the total number of points connected to the panel cannot exceed 119. 2. In Table 2, enter devices used on Auxiliary Power. Calculate standby and alarm currents, then add to get Auxiliary Power current subtotal. Table 2: Auxiliary Power Current Load Total Current Device Model # Device Current X # of Units Standby Alarm Auxiliary Power Subtotal (terminals 6 & 7 – 750mA max.) Section 3 - Installing the Control 3-37 3. In Table 3, enter devices connected to the Alarm Output. Calculate alarm currents, then add to get the Alarm Output current subtotal. Table 3: Alarm Output Current Load Total Current Device Model # Device Current X # of Units Standby Alarm XXXXXX XXXXXX XXXXXX XXXXXX XXXXXX XXXXXX XXXXXX Alarm Output Subtotal (terminals 4 & 5 – 1.7A max.) 4. In Table 4, enter the total calculated subtotals of all listed outputs from Tables 1 through 3, then add to get the combined current. Table 4: Total VISTA-128BP/VISTA-250BP Current Load Total Current Standby Alarm Polling Loop Subtotal (see Table 1) Aux. Power Subtotal (see Table 2) Alarm Output Subtotal (see Table 3) VISTA-128BP/VISTA-250BP PCB Current (Includes 2-wire smoke detector loading on zone 1) 250mA 330mA Total Current Load Determining the Size of the Standby Battery The cabinet supplied with the control panel can house batteries of up to 12V, 14AH (two 12V, 7AH batteries wired in parallel). The VISTA-ULKT kit provides a cabinet that can house batteries of up to 12V, 17.2AH and that may be used with this panel. The total standby current drawn from the auxiliary power and polling loop outputs combined must be limited to 270mA when 14AH batteries are used; and to 390mA when 17.2AH batteries are used. DO NOT use Gates batteries (sealed lead-acid type). These batteries require a different charging voltage than is supplied by the panel. UL Household Fire or Combination Household/Fire/Burglary installations require the use of a backup battery that is capable of providing 24 hours of standby time followed by 4 minutes of alarm time. UL1023 Household Burglary-only installations require the use of a backup battery that is capable of providing 4 hours of standby time followed by 4 minutes of alarm time. Use Table 5 to determine the required backup battery capacity and use Table 6 to determine the battery model number. A dual battery harness is supplied that allows two batteries to be wired in parallel for increased capacity. 5. Using the total calculated from Table 4, calculate the battery capacity required for the installation. Table 5: Battery Capacity Calculation Table Capacity Formula Calculated Value Standby Capacity For 4-hour standby time: Total standby current X 4 hours X 1.4 contingency factor. For 24-hour standby time: Total standby current X 24 hours X 1.1 contingency factor. Alarm Capacity For 4-, 5-, or 15-minute alarm time: Total alarm curr. X 0.067 (4 min) 0.250 (15 min) VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-38 Total Capacity Add standby and alarm capacities 6. Use the Battery Selection Table to select the appropriate battery for the installation. Table 6: Battery Selection Table Capacity Recommended Battery Comment 4AH Yuasa NP4-12 7AH Yuasa NP7-12 12AH Yuasa NP12-12 Fits in large mercantile cabinet only. 14AH Yuasa NP7-12 Connect two in parallel. 17.2AH Yuasa NPG18-12 Fits in large mercantile cabinet only. 7. Connect the battery, referring to Figure 3-42. The standby battery is automatically tested for 10 minutes every 4 hours, beginning 4 hours after exiting Programming mode. In addition, entry into the Test mode initiates a battery test. The VISTA-128BP/VISTA-250BP also runs a 5-second battery test every 60 seconds to check if the battery is connected. 4-1 SECTION 4 Programming •••••••••••••••••••••••••••••••••••••••••••••••• • NOTE: All references in this manual for number of zones, number of user codes, number of access cards, and the event log capacity, use the VISTA-250BP’s features. See SECTION 1: General Description for the table listing the differences between the VISTA-128BP and the VISTA-250BP control panels. Program Modes There are two programming modes for the VISTA- 128BP/VISTA-250BP. These are the Data Field Program Mode and the #93 Menu Mode. The Data Field Program Mode is where many system options are programmed. The #93 Menu Mode is an interactive mode that requires a 2-line alpha keypad (6139/6160). The factory-loaded defaults (✳97) enable keypad addresses 00-01 only. A keypad set to one of these addresses must be used to program the system initially. Local keypad programming can be disabled through Compass downloading software. If this is done, Program mode can only be accessed via the downloading software. Entering and Exiting Programming Mode Enter Programming mode using either method a or b: a. Press both the [✳] and [#] keys at the same time within 30 seconds after power is applied to the control. b. Enter the Installer Code + [8] + [0] + [0] + [0] keys. The factory installer code can be changed once in the Program mode (field ✳00). NOTE: The default for the Installer Code is 4140. Exit the Programming mode by either method a or b: a. Press [✳] + [9] + [8]. Exiting by this method prevents the installer code from being used to re- enter Programming mode. Only method “a” can be used to re-enter Programming mode. b. Press [✳] + [9] + [9]. Exiting by this method permits the installer code to be being used to re- enter Programming mode. Data Field Programming Mode In the Data Field Program Mode you may access any field simply by entering either [✳] or [#] + the field number: • To write or change information in a field press [✳] + the field number (✳03). • To read the information in a field press [#] + the field number (#03). When the entries for a field are completed, the keypad beeps three times and advances to the next field. Summary of Data Field Programming Commands ✳91 Select partition for programming partition-specific fields ✳92 Display the software revision level of the control panel ✳93 Enter Menu mode programming ✳94 Go to next page of fields ✳99 Go back to previous page of fields or exit Programming Mode with no installer code lockout ✳98 Exit Programming Mode with Installer Code lockout Moving Between Programming Levels The data fields are grouped into three levels (referred to as “pages”). The first page is accessed as soon as Programming Mode is entered. The second and third pages of data fields are indicated at the keypad by a 1 and 2, respectively, in front of the 2-digit field address. “ALT PROGRAM MODE” is displayed along with a “100” or “200,” indicating which page of program fields is accessed. To access the next level of programming fields, perform the following steps: Step Action 1 Press ✳94. 2 Press [✴] + [XX], where XX = the last two digits of the program field, and make the desired entry. NOTES: Press ✳94 to move to 2nd page, (fields 1✳01 - 1✳76); press ✳99 to move back to 1st page. VISTA-128BP/VISTA-250BP Installation and Setup Guide 4-2 Press ✳94 to move to 3rd page (fields 2✳00 - 2✳88); press ✳99 to move back to 2nd page Entry Errors • If an address is improperly entered, the keypad displays “FC.” • If a program entry is improperly entered (for example, a larger number than is permitted), the keypad display will go blank. In either of the above cases, simply re-enter [✳] + the correct field number and then enter the correct data. Programming System-Wide Data Fields Values for some programming fields are system-wide (global), and some can be different for each partition (partition-specific). The partition-specific programming fields are automatically skipped when programming the global fields. If the system has only 1 partition, the partition-specific fields are not automatically skipped. To program system-wide data fields, perform the following steps: Step Action 1 Enter Program Mode: Installer Code + 8 0 0 0. The following display appears: Program Mode ✳Fill # View – 00 2 If the control has not been programmed before, enter ✳97 to load factory defaults. 3 Press [✳] and enter the first field number to be programmed (for example, ✳00, Installers Code). Make the desired entry. When the field is complete, the keypad beeps three times and advances to the next field. If you do not want to change the next field, press [✳] and enter the next field number to be programmed. First Page of fields (✳00 - ✳90) To change to the next page of fields, press ✳94. To return to the previous page of fields, press ✳99. 4 Press ✳99 or ✳98 to exit Program Mode. NOTE: If the number of digits that you enter in a data field is fewer than the maximum permitted (for example, a phone number), the keypad displays the last entry and waits. To proceed, enter [✳] + the next data field you wish to program. Programming Partition-Specific Data Fields To program partition-specific data fields once in Program Mode, do the following: Step Action 1 Enter Program Mode: Installer Code + 8 0 0 0. 2 Press ✳91, which will prompt you for the partition number desired. 3 Enter a partition-specific field number (e.g., ✳09) to begin programming. When the first field’s entry is completed, the next partition-specific field is automatically displayed. When all partition-specific fields are programmed, the system returns to the global programming fields (page 1 fields). 4 Repeat this procedure for each partition in the installation. NOTE: To return to the global program fields before finishing all fields, enter any global field number. Programming Partition-Specific Fields Press ✳91 to select a partition. ↓↓↓↓ Enter the partition to be programmed. ↓↓↓↓ Enter a partition-specific field number and make entry. ↓↓↓↓ After partition-specific fields are programmed, press ✳91 to select next partition. Enter any global field number to return to the global fields at any time. #93 Menu Mode Programming The #93 Menu Mode is an interactive mode through which much of the system’s programming is done. In this mode, there are “question and answer” prompts that can be accessed once Data Field Program Mode has been entered. These prompts require a 2-line alpha keypad (6139/6160). After programming all system-related programming fields in the usual way, press #93 while still in VISTA-128BP/VISTA-250BP Installation and Setup Guide 4-2 programming mode to display the first choice of the menu-driven programming functions. Press 0 (NO) or 1 (YES) in response to the displayed menu selection. Pressing 0 will display the next choice in sequence. Below is a list of the main menus. For details refer to the VISTA-128BP/VISTA-250BP Programming Guide. MAIN MENU OPTIONS ZONE PROG? 1 = YES 0 = NO 0 For programming the following: • Zone Number • Zone Response Type • Partition Number for Zone • Dialer report code for zone • Input Device Type for zone (whether RF, polling loop, etc.) • Enrolling serial numbers of 5800 Series transmitters & serial polling loop devices into the system. • Zone Attributes (e.g., Arm w/Fault, Silent, etc.). EXPERT MODE? 1 = YES 0 = NO 0 Same as Zone Programming except: • Done with a minimum number of keystrokes. • Can program wireless keys using pre-defined templates. REPORT CODE PROG? 1 = YES 0 = NO 0 For programming the following: • Alarm report codes for zones • Restore and supervisory codes • All other system report codes ALPHA PROG? 1 = YES 0 = NO 0 For entering alpha descriptors for the following: • Zone Descriptors • Installer’s Message • Custom Words • Partition Descriptors • Relay Descriptors DEVICE PROG? 1 = YES 0 = NO 0 For defining the following device characteristics for addressable devices, including keypads, RF receivers (5881), output relay modules (4204/4204CF), FSA (FSA-8/FSA-24), 4285/4286 VIP Module, Panel Link Module (VA8201), ECP long range radio (7845C), and VISTA Gateway Module: • Device Address • Device Type • Keypad Options (including Partition assignment) • RF House ID • LRR Options (including Programming radio) OUTPUT PGM? 1 = YES 0 = NO 0 For defining output device functions. RLY VOICE DESCR? 1 = YES 0 = NO 0 For entering voice descriptors for relays to be used with the 4285/4286 VIP Module. CUSTOM INDEX ? 1 = YES 0 = NO 0 For creating custom word substitutes for VIP Module annunciation. ACCESS POINT PGM 1 = YES 0 = NO 0 For defining the parameters for each of the VistaKey zones, including which group(s) have access through an access point (door). See the VistaKey-SK Installation and Setup Guide for detailed programming instructions. ACCESS GRP PGM 1 = YES 0 = NO 0 For defining the capabilities (privileges) for each group of users. See the VistaKey-SK Installation and Setup Guide for detailed programming instructions. EVENT/ACTION PGM 1 = YES 0 = NO 0 For defining events and time windows for an access group. See the VistaKey-SK Installation and Setup Guide for detailed programming instructions. SCHEDULED CHK-IN For defining the schedule for the system to automatically call the downloader. VISTA-128BP/VISTA-250BP Installation and Setup Guide 4-4 1 = YES 0 = NO 0 Following is a list of commands used while in the Menu Mode: #93 Menu Mode Programming Commands #93 Enters Menu Mode. [✳] Serves as [ENTER] key. Press to have keypad accept entry. [#] Backs up to previous screen. 0 Press to answer NO. 1 Press to answer YES. 00, or 000+[✳] Quits Menu Mode and goes back to Data Field Programming Mode, if entered at first prompt of each main menu option. Zone Number Designations The VISTA-128BP supports up to 128 zones, the VISTA-250BP supports up to 250 zones, of hardwire, polling loop and/or wireless protection, distributed among up to 8 partitions. The following table lists the zone numbers and the types of sensors that can be used with each, and some alternate functions of the zones. Zone Function 1 2-wire Smoke Detectors (if used) 5 Audio Alarm Verification (if used) 7 Keyswitch (if used) 8 Latching-Type Glassbreak Detectors (if used) 1-9 Traditional Hardwired Zones 9 RS232 Input (if used) 1-250 5800 Series Wireless Devices 10-250 Polling Loop Devices 995 ✳ + 1 Panic 996 # + 3 Panic 999 ✳ + # Panic Zone Defaults Zone # Zone Type Zone # Zone Type 001 09 601-632 00 002 03 800-830 00 003 03 970 00 004** 04 988 00 005 03 990 00 006 03 992* N/A 007 03 995 00 008 03 996 00 009 03 997 05 010–250 00 999 06 NOTES: * Zone 992 is the Duress zone. Programming of the zone response type is not applicable. This zone requires only the report code programming. ** Zone 004 is also defaulted with Auto-STAY enabled. Zone Index The zones are designated as follows: ZONE # RANGE ZONE FUNCTION ACTUAL ZONE 001 – 250 Protection zones As indicated 601 – 632 Relay Supervisory Zones 6 + 2-digit Relay Number; e.g., Relay Number 03 is zone 603. 800 – 830 ECP Device Supervisory Zones 8 + 2-digit Device Address; e.g., Device Address 01 is zone 801. VIP Module is zone 804 (Device Address must be set to 4). TeleSmart is zone 824 (Device Address must be set to 24). 970, 988, 990, & 997 System Supervisory Zones 970: Bell Supervision 988: 2nd Wireless Receiver – not receiving signals 990: 1st Wireless Receiver – not receiving signals 997: Polling Loop (short circuit) 992, 995 – 999 Duress and Keypad Panics 992: Duress 995: 1 + ✳ panic (A key) 996: 3 + # panic (C key) 999: ✳ + # panic (B key) Program supervisory zones with response type of 05. Communication Defaults *45 PRIMARY FORMAT [1] ADEMCO Contact ID *46 LOW SPEED FORMAT (Prim) [0] ADEMCO Low Speed *47 SECONDARY FORMAT [1] ADEMCO Contact ID *48 LOW SPEED FORMAT (Sec.) [0] ADEMCO Low Speed *49 CHECKSUM VERIFICATION [0] [0] No checksum Primary Secondary *50 SESCOA/RADIONICS SEL. [0] Radionics *51 DUAL REPORTING [0] no *52 STANDARD/EXPANDED REPORT FOR PRIMARY [0] [0] [0] [0] [0] [0] standard Alarm Rstr Bypass Trbl Opn/Cls Low Bat *53 STANDARD/EXPANDED REPORT FOR SECONDARY [0] [0] [0] [0] [0] [0] standard Section 4 – Programming 4-5 Alarm Rstr Bypass Trbl Opn/Cls Low Bat Communication Defaults for Zones ZONE # 1st 2nd ZONE # 1st 2nd ZONE # 1st 2nd ZONE # 1st 2nd 1 01 00 50 05 00 99 09 00 148 13 00 2 02 00 51 06 00 100 10 00 149 14 00 3 03 00 52 07 00 101 11 00 150 15 00 4 04 00 53 08 00 102 12 00 151 01 00 5 05 00 54 09 00 103 13 00 152 02 00 6 06 00 55 10 00 104 14 00 153 03 00 7 07 00 56 11 00 105 15 00 154 04 00 8 08 00 57 12 00 106 01 00 155 05 00 9 09 00 58 13 00 107 02 00 156 06 00 10 10 00 59 14 00 108 03 00 157 07 00 11 11 00 60 15 00 109 04 00 158 08 00 12 12 00 61 01 00 110 05 00 159 09 00 13 13 00 62 02 00 111 06 00 160 10 00 14 14 00 63 03 00 112 07 00 161 11 00 15 15 00 64 04 00 113 08 00 162 12 00 16 01 00 65 05 00 114 09 00 163 13 00 17 02 00 66 06 00 115 10 00 164 14 00 18 03 00 67 07 00 116 11 00 165 15 00 19 04 00 68 08 00 117 12 00 166 01 00 20 05 00 69 09 00 118 13 00 167 02 00 21 06 00 70 10 00 119 14 00 168 03 00 22 07 00 71 11 00 120 15 00 169 04 00 23 08 00 72 12 00 121 01 00 170 05 00 24 09 00 73 13 00 122 02 00 171 06 00 25 10 00 74 14 00 123 03 00 172 07 00 26 11 00 75 15 00 124 04 00 173 08 00 27 12 00 76 01 00 125 05 00 174 09 00 28 13 00 77 02 00 126 06 00 175 10 00 29 14 00 78 03 00 127 07 00 176 11 00 30 15 00 79 04 00 128 08 00 177 12 00 31 01 00 80 05 00 129 09 00 178 13 00 32 02 00 81 06 00 130 10 00 179 14 00 33 03 00 82 07 00 131 11 00 180 15 00 34 04 00 83 08 00 132 12 00 181 01 00 35 05 00 84 09 00 133 13 00 182 02 00 36 06 00 85 10 00 134 14 00 183 03 00 37 07 00 86 11 00 135 15 00 184 04 00 38 08 00 87 12 00 136 01 00 185 05 00 39 09 00 88 13 00 137 02 00 186 06 00 40 10 00 89 14 00 138 03 00 187 07 00 41 11 00 90 15 00 139 04 00 188 08 00 42 12 00 91 01 00 140 05 00 189 09 00 43 13 00 92 02 00 141 06 00 190 10 00 44 14 00 93 03 00 142 07 00 191 11 00 45 15 00 94 04 00 143 08 00 192 12 00 46 01 00 95 05 00 144 09 00 193 13 00 47 02 00 96 06 00 145 10 00 194 14 00 48 03 00 97 07 00 146 11 00 195 15 00 49 04 00 98 08 00 147 12 00 196 01 00 197 02 00 215 05 00 232 07 00 249 09 00 198 03 00 216 06 00 233 08 00 250 10 00 199 04 00 217 07 00 234 09 00 601-632 00 00 200 05 00 218 08 00 235 10 00 800-830 00 00 201 06 00 219 09 00 236 11 00 970 00 00 202 07 00 220 10 00 237 12 00 988 00 00 203 08 00 221 11 00 238 13 00 990 00 00 204 09 00 222 12 00 239 14 00 992 (DURESS) 11 00 205 10 00 223 13 00 240 15 00 995 00 00 206 11 00 224 14 00 241 01 00 996 00 00 207 12 00 225 15 00 242 02 00 997 06 00 208 13 00 226 01 00 243 03 00 999 06 00 VISTA-128BP/VISTA-250BP Installation and Setup Guide 4-6 ZONE # 1st 2nd ZONE # 1st 2nd ZONE # 1st 2nd ZONE # 1st 2nd 209 14 00 227 02 00 244 04 00 ALARM RST. 00 00 210 15 00 228 03 00 245 05 00 TROUBLE 00 00 211 01 00 229 04 00 246 06 00 TRBLE. RST 00 00 212 02 00 230 05 00 247 07 00 BYPASS 00 00 213 03 00 231 06 00 248 08 00 BYP. RST. 00 00 214 04 00 Zone Response Type Definitions Each zone must be assigned a zone type, which defines the way in which the system responds to faults in that zone. There are three keypad-activated zones (panic keys; see note) for each partition, a polling loop supervision zone, and four RF supervisory zones, two for each RF receiver installed. Zone types are defined below. Type 00: Zone Not Used Program with this zone type if the zone is not used. Type 01: Entry/Exit #1 Burglary Provides entry delay whenever the zone is faulted and the system is armed in the AWAY or STAY mode. When the panel is armed in the INSTANT or MAXIMUM mode, no entry delay is provided. Exit delay begins whenever the control is armed, regardless of the arming mode selected. These delays are programmable. Assign this zone type to zones that are used for primary entry to and exit from the facility. Type 02: Entry/Exit #2 Burglary Provides a secondary entry delay, if the system is armed in the AWAY or STAY modes and the zone is faulted. When the panel is armed in the INSTANT or MAXIMUM mode, no entry delay is provided. Secondary exit delay begins whenever the control is armed, regardless of the arming mode selected. These delays are programmable. Assign this zone type to zones that are used for entry and exit of the facility and require more time than the primary entry and exit point. Delay times for this zone type must be greater than those for zone type 01 (e.g., a garage, loading dock, or basement door). Type 03: Perimeter Burglary Provides an instant alarm if the zone is faulted and the system is armed in the AWAY, STAY, INSTANT, or MAXIMUM mode. Assign this zone type to all exterior door and window zones. Type 04: Interior, Follower Provides a delayed alarm (using the programmed entry delay time) if an entry/exit zone is faulted first. Otherwise it produces an instant alarm. It is active when the system is armed in the AWAY or MAXIMUM mode, but the MAXIMUM mode eliminates the entry delay. If the Interior Follower zone is programmed for one of the STAY modes (default is STAY mode 1), it is automatically bypassed when the panel is armed in the STAY or INSTANT mode. Assign this zone type to a zone covering an area such as a foyer, lobby, or hallway through which one must pass upon entry or exit (to and from the keypad). Type 05: Trouble by Day/Alarm by Night Provides an instant alarm if the zone is faulted and the system is armed in the AWAY, STAY, INSTANT, or MAXIMUM mode. During the disarmed state (day), the system annunciates a latched trouble sounding from the keypad (and a central station report, if desired). Assign this zone type to a zone that contains a foil- protected door or window (such as in a store), or to a zone covering a sensitive area such as a stock room or drug supply room. It can also be used on a zone in an area where immediate notification of an entry is desired. Type 06: 24-Hour Silent Alarm Sends a report to the central station but provides no keypad display or sounding. Assign this zone type to a zone containing an Emergency button. Type 07: 24-Hour Audible Alarm Sends a report to the central station and provides an alarm sound at the keypad and an audible external alarm. Assign this zone type to a zone containing an Emergency button. Type 08: 24-Hour Auxiliary Alarm Sends a report to central station and provides an alarm sound at the keypad only. (No bell output is provided.) Assign this zone type to a zone an Emergency button or one containing monitoring devices such as water sensors or temperature sensors. Type 09: Supervised Fire (Without Verification) Section 4 – Programming 4-7 Provides a fire alarm on a short circuit and a trouble condition on open circuit. A fire alarm produces a pulsing of the bell output. A zone of this type is always active and cannot be bypassed. Type 10: Interior with Delay Provides entry and exit delays (using the programmed entry and exit delay times) when armed in the AWAY mode. Provides only exit delay when armed in the MAXIMUM mode (no entry delay). If the Interior with Delay zone is programmed for one of the STAY modes (default is STAY mode 1), it is automatically bypassed when the panel is armed in the STAY or INSTANT mode. Delay begins whenever sensors in this zone are violated, regardless of whether or not an entry/exit delay zone was tripped first. Assign this zone type to a zone covering an area such as a foyer, lobby, or hallway through which one must pass upon entry or exit (to and from the keypad). Type 14: PLM Supervision Provides supervision of remote Panel Link Modules. If the communication between the local PLM and a remote PLM fails, a trouble message is produced for the PLM zone. Type 16: Fire With Verification Provides a fire alarm on a short circuit and a trouble condition on open circuit. An initial short detection causes 7-second smoke detector power reset. A subsequent short detection within 90 seconds of the reset causes a fire alarm. A fire alarm produces a pulsing of the bell output. A zone of this type is always active and cannot be bypassed. Type 20: Arm-STAY (5800 Series devices only) Causes the system to arm in the STAY mode when the zone is activated. Type 21: Arm-AWAY (5800 Series devices only) Causes the system to arm in the AWAY mode when the zone is activated. Type 22: Disarm (5800 Series devices only) Causes the system to disarm when the zone is activated. Type 23: No Alarm Response Used on a zone when an output relay action is desired, but with no accompanying alarm (e.g., for lobby door access). Type 27: Access Point Assign this zone type to an input device (hardwired zone, wireless zone, keypad, access control relay, etc.) that controls an access entry point (e.g., a door). The access point entry relay can be assigned to an access control relay (controlled by the VISTA-128BP/VISTA- 250BP), ECP relay (4204), or to the access control system independent of the control panel. Type 28: Main Logic Board (MLB) Supervision Used to supervise the MLB. If communication between the MLB and the VISTA Gateway Module (VGM) fails, a trouble condition is annunciated for the zone. Also, if the communication fails, all access control system (ACS) input zones also display a “CHECK.” Type 29: Momentary Exit Used to cause an access point programmed for entry to revert to an exit point for 15 seconds. After the 15 seconds, it automatically reverts back to an entry point. This zone type should be used only with VistaKey modules. NOTE FOR PANIC KEYS: Keypad panic zones share the same zone response type for all 8 partitions, but panics may be individually enabled for each partition. IMPORTANT! FAULT ANNUNCIATION Polling loop and RF troubles (zones 988, 990, and 997) report as trouble conditions only, and as such, should be assigned zone type 05 if annunciation is desired. See Polling Loop Supervision and RF System Operation and Supervision in SECTION 3 Installing the Control for more information. Zone Input Type Definitions Each zone must be assigned an input type, which defines the where the system will “look” for status of the zone (RF receiver, polling loop, etc.). Zone input types are defined below. Type 01 Hardwired (HW) Reserved for the built-in hardwired zones 1-9. Type 02 RF Motion (RM) Select for 5800 Series RF transmitters. Sends periodic check-in signals, as well as fault and low-battery signals. The control panel automatically restores the zone to “ready” after a few seconds. This type is designed for facilities with multiple motion detectors that may fault and restore simultaneously. The transmitter must remain within the receiver’s range. NOTE: If using RF Motion with a door/window type transmitter, only loop 1 may be used. Type 03 Supervised RF (RF) Select for 5800 Series RF transmitters that will be supervised for check-in signals. The transmitter must remain within the receiver’s range. Type 04 Unsupervised RF (UR) Select for 5800 Series RF transmitters that will not be supervised for check-in signals. The transmitter may therefore be carried off-premises. VISTA-128BP/VISTA-250BP Installation and Setup Guide 4-8 Type 05 Unsupervised Button RF (BR) Select for 5800 Series RF transmitters specifically designed for this input type. Check the transmitter’s instructions for proper programming of the input type. These transmitters send only fault signals. They do not send low-battery signals until they are activated. The transmitter may be carried off-premises. Type 06 Serial Number Polling Loop (SL) Select for polling loop devices with a built-in serial number. For VistaKey, select this type for Door Status Monitor Backup DSMB. If local power to the VistaKey is lost, a V-Plex SIM, located on the VistaKey board, is powered directly from the polling loop and reports the state of the DSM via the standard V-Plex polling system. NOTE: To obtain the DSMB function, the Input Type must be defined as 06 and the next prompt in Zone Programming (Access Point) must contain the Access Point number (01-15) (address of the VistaKey module). Type 07 DIP Switch Loop (DP) Select for polling loop devices that use DIP switches for programming the zone number of the device. Type 08 Dip Switch Polling Loop Right Loop (PS) Select for the second loop of two-zone polling loop devices (e.g., 4190WH; 4278). Type 09 Console Input (CS) Select when this zone is to be controlled by a keypad input (user code + [#] + [7] + [3]) for access control. Type 10 PassPoint Access Control (ACS) Select when this zone is mapped to a zone on the PassPoint Access Control System. Type11 VistaKey Door Status Monitor (DSM) Select this input type when using a VistaKey module connected to a door. This must be programmed for each VistaKey module to provide the DSM zone mapping a panel zone. If this is not programmed the panel will not “see” the VistaKey module. It is also used to determine the door is opened after a card swipe or if the door is being held open. The device is normally a magnetic switch mounted on the door. The status of the switch is different when the door is in an open position. Type 12 VistaKey Request to Exit (RTE) Use this input type to map an uncommitted RTE zone to an alarm panel zone. This input type is not normally used if the zone is used for a request-to-exit function. Type 13 VistaKey General Purpose (GP) This input type operates in the same manner as other VISTA-128BP/VISTA-250BP alarm panel zones and is provided so that a zone in the proximity of the VistaKey can be wired without having to run additional wiring from the control panel. Programming for Panel Linking Step Action 1 Program the Panel Link Module (PLM) into the system in Device Programming in the #93 Menu Mode with Device Type 10. 2 If you want to supervise the PLM, program zone 8xx with response type 05, where “xx” = the module’s address. If you want the zone to report to the central station, make sure the report code for the zone is set with a non-zero value. Step Action 3 If you want to supervise the PLMs connected to other controls, program those modules in Zone Programming with response type 14. Also, program the panel ID number. The ID number must match the ID number programmed in Device Programming of the control panel the PLM is connected. If you want the zone to report to the central station, make sure the report code for the zone is set with a non-zero value. Be sure to program the input type with 00. See Device Programming and Zone Programming in #93 Menu Mode Programming in the Programming Guide for a detailed explanation of the programming procedures. Programming for the Alpha Pager Module • ✳05 Enter 1 to print all zone faults/restores; enter 0 to print only events enabled in field 1✳70 • ✳14 Enter 1 if using Home Automation • 1✳69 Printer selection 0 for parallel; 1 for serial • 1✳70 Event Log Types (1=enable; 0=disable) • 1✳71 12/24-Hour Time Stamp (0=12 hr; 1=24 hr) • 1✳72 Printer On-line (must be 1 (enable) for APM) • 1✳73 Enter 0 for 1200 Baud Rate Section 4 – Programming 4-9 • 2✳30 Enter 1 to enable the Alpha Pager Module. • 2✳31 - 2✳88 Paging service parameters. The events (e.g., field 2*39) must be programmed for the pager to work. Fields for programming the delay times (e.g. 2*36 and 2*37 for pager 1) are relevant only when using numeric format for the pager. NOTE: For Event Log Report Codes program System Group #2 in the #93 Menu Mode. Programming for 4100SM • ✳05 Enter 1 to print all zone faults/restores; enter 0 to print only events enabled in field 1✳70 • ✳14 Enter 1 if using Home Automation (cannot use both serial printer and Home Automation) • 1✳69 Not applicable • 1✳70 Event Log Types (1=enable; 0=disable • 1✳71 12/24-Hour Time Stamp (0=12 hr; 1=24 hr) • 1✳72 Printer On-line (0=disable; 1=enable) • 1✳73 Enter 0 for 1200 Baud Rate NOTE: For Event Log Report Codes program System Group #2 in the #93 Menu Mode. Programming for Access Control VistaKey See the VistaKey-SK Installation and Setup Guide for the detailed programming instructions. VistaKey Dialer Enables When the VistaKey is installed with an alarm system, the system defaults are set so that the system does not send reports to the central station. The programming is accomplished in field 1∗35 for the following events: • ACS Troubles - To enable or disable ACS trouble reporting. • ACS Bypasses - To enable or disable ACS bypass reporting. • ACS System - To enable or disable ACS system reporting, (i.e., ACS module reset). • ACS Alarms - To enable or disable ACS alarm reporting. • Dialer (Trace) - To enable or disable access grant/denial events sent to the central station. PassPoint The PassPoint ACS can dedicate some of its inputs for use as regular VISTA-128BP/VISTA-250BP hardwired zones (the zone response type is ACS). The PassPoint ACS can also utilize the control panel dialer for reports to the central station. PassPoint Dialer Events All PassPoint ACS events can be sent to the VISTA- 128BP/VISTA-250BP dialer via the VGM. These events will also be logged into the control’s event log. This is enabled in the PassPoint ACS. See the PassPoint ACS documentation for a detailed explanation. Programming the VISTA Gateway Module See the PassPoint ACS instructions to program the VISTA Gateway Module. Using ACS Zone Inputs If the PassPoint ACS has uncommitted zones, these may be used by the VISTA-128BP/VISTA-250BP as hardwired zones. To program for ACS zone inputs, perform the following steps: Step Action 1 Enter Zone Programming in the #93 Menu Mode. 2 Program this zone as any other zone. Indicate the input type as ACS (10). 3 Enter the PassPoint ACS’s zone ID (00-31) See Zone Programming in the Programming Guide for a detailed explanation. Access Control of an Entry/Exit Point The control can send entry and exit requests to the VistaKey or PassPoint ACS utilizing keypads and button-type (BR) RF transmitters. A zone is programmed with a response type 27 (Access Point) and an appropriate input type (console, RF). Using the Alpha Keypad Step Action 1 Enter Zone Programming in the #93 Menu Mode. 2 Program the zone with a response type 27 (Access Point). 3 Enter the access point number (00-31) of the door. 4 Program whether this is an entry or exit point. 5 Enter the partition number. 6 Enter the input type as CS (09). 7 Enter the keypad ECP address. See Zone Programming in the Programming Guide for a detailed explanation. Using Wireless Keypads Wireless keypads (5827 & 5827BD) can provide another way of entering or exiting the premises. They VISTA-128BP/VISTA-250BP Installation and Setup Guide 4-10 function the same as alpha keypads, except when the code + # 73 is entered. This entry will allow momentary access to ALL access points in the partition to which the keypad is assigned. To program the wireless keypad, enter the partition the keypad is assigned to in field 1*48. Using an RF Transmitter Zone A button type RF transmitter (5804) can be used to provide access or egress for up to 4 doors. One button will control one door. Also, a button can be used to provide access or egress due to a panic or duress condition. An RF transmitter (5816) can be used with a remote switch to provide exit in case of a fire alarm using a PassPoint event action. To program the RF transmitter for access control, perform the following steps: Step Action 1 Enter Zone Programming in the #93 Menu Mode. 2 Program the zone with a response type 27 (Access Point). 3 Enter the access point number (00-31) of the door. 4 Indicate whether RF device is for entry or exit. 5 Enter the partition number 6 Enter the input type: button RF (03). 7 Enter the loop number. 8 Enroll the serial number See Zone Programming in the Programming Guide for a detailed explanation. • RF buttons and pendants must be assigned to a user number in order to function. See SECTION 9: User Access Codes for the procedure. • An RF transmitter will not provide access or grant if the system is in any test mode. Control of Lighting and Appliances Lighting and appliances can be controlled when an access or exit event occurs. Lights or appliances can be automatically turned on or off when a valid entry or egress request is presented at an access point. To control these devices, the VISTA-128BP/VISTA-250BP relays or the ACS relays or triggers are used with keypads and/or RF transmitters whose response type is Access Point (27). To program the control of lighting and appliances, perform the following steps: Step Action 1 Enter Output Programming in the #93 Menu Mode. 2 Program all the information for the relay. 3 Select the output type: ECP (1) (4204) or (2) (X-10). See Output Programming in the Programming Guide for a detailed explanation. Using the VISTA-128BP/VISTA-250BP for Stand- Alone Access Control The VISTA-128BP/VISTA-250BP can be used for access control without interfacing to PassPoint ACS or VistaKey. A user can trigger an access point (i.e., door strike) for 2 seconds by entering User Code + [0]. To program the VISTA-128BP/VISTA-250BP for Stand- Alone access control, perform the following steps: Step Action 1 Enter Output Programming in the #93 Menu Mode. 2 Program the output type as 1, or 2. 3 For type 1, program the ECP address and relay number. 4 For type 2, program the house and unit codes. 5 Program the relay number in field 1∗76 (partition-specific). See Output Programming in the Programming Guide for a detailed explanation. Programming for ECP Long Range Radio • Program the LRR in Device Programming in the #93 Menu Mode Programming. • Field ✳56: Selects the time the panel should wait before it attempts to send a message to the second destination. • Field ✳57: Select the initial reporting destination for messages. • Field ✳58: Select events for the primary sub’s ID • Field ✳59: Select events for the secondary sub’s ID. Programming for TeleSmart The TeleSmart module has a fixed address of 24 (it cannot be changed). Set Device Address 24 for Device Type 11 in the control’s Device Programming mode. Also, Device Address 23 must be set for Device Type 01, Alpha Console, but do not actually connect a device to the control panel set to that address. Section 4 – Programming 4-11 This must be done so that TeleSmart can be accessed remotely (off premises). Refer to Device Programming in the #93 Menu Mode in the VISTA-128BP/VISTA-250BP Programming Guide for specific instructions. 5-1 SECTION 5 Data Field Descriptions •••••••••••••••••••••••••••••••••••••••••••••••• • About Data Field Programming The following pages list this control’s data fields in numerical order. Field numbers are listed in the left column, followed by a “Title and Data Entries column, which lists the valid entries for each field. Experienced installers can simply follow this column when programming the data fields. The “Explanation” column provides explanatory information and special notes where applicable. NOTE: Refer to the Programming Guide for the default values. They are not listed in this section. Use the Programming Guide to record the data for this installation. NOTE: All references in this manual for number of zones, number of user codes, number of access cards, and the event log capacity, use the VISTA-250BP’s features. See SECTION 1: General Description for the table listing the differences between the VISTA-128BP and the VISTA-250BP control panels. All other features are identical, except for the Remote Keypad Sounder (field 1✴46 option 2), which is available only in the VISTA128BP. Programming Data Fields Data field programming involves making the appropriate entries for each of the data fields. Start Data Field programming by entering the installer code + 8 + 0 + 0 + 0. FIELD TITLE and DATA ENTRIES EXPLANATION *00 Installer Code Enter 4 digits, 0-9 The Installer Code is a 4-digit code reserved for installation company use. This is the only code that can be used to enter the Program Mode from the keypad. This code cannot be used to disarm the system if it isn’t used to arm the system. This code cannot be used to re-enter Program Mode if Program Mode is exited by the *98 command. *04 Enable Random Timers For Partitions 1-8 0 = disable 1 = enable If enabled, the activation time of the window is randomized up to 30 minutes and is initialized by either of two methods: User Code + [#] + [41] Initiates the random schedule for all devices in the partition. User Code + [#] + [42] Initiates the random schedule for all devices in the partition with a time window within 6 PM and 5 AM. *05 System Events Notify 0 = disable 1 = enable If enabled the system sends notification messages via the RS232 port. Field *14 must be set for RS232 port (1). NOTE: If enabled, the system also sends fault and restore messages via the RS232 port. Quick Exit (partition-specific) 0 = disable 1 = enable If enabled, allows users to exit the armed partition without disarming and then rearming the partition. Quick Exit is initiated by entering [#] + [9]. This restarts the exit delay. All rules of exit apply, including exit error logic. UL Quick Exit is not permitted for use with the VISTA-128BP/VISTA-250BP Control Panel in a UL installation. *06 VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-2 FIELD TITLE and DATA ENTRIES EXPLANATION *09 Entry Delay #1 (partition-specific) Enter 02-15 multiplied by 15 seconds. 00 = no delay. Entry delay defines the delay time that allows users to re-enter the premises through a door that has been programmed as an entry delay door and disarm the system without sounding an alarm. The system must be disarmed within this period or an alarm will occur. NOTE: The delay may not exceed 45 seconds for UL installations. SIA Guidelines: The entry delay time and Burg Alarm Comm Delay (field *88) combined cannot exceed 1 minute. *10 Exit Delay #1 (partition-specific) Enter 03-15 multiplied by 15 seconds. 00 = no delay. Exit delay defines the delay period that allows users to leave the premises through a door that has been programmed as an entry/exit delay door after arming the system without setting off the alarm. NOTE: SIA Guidelines: The delay must be set for a minimum 45 seconds. *11 Entry Delay #2 (partition-specific) Enter 02-15 multiplied by 15 seconds. 00 = no delay. Entry Delay #2 is used for a secondary door requiring a longer delay than those assigned to Entry Delay #1. NOTE: The delay may not exceed 45 seconds for UL installations. SIA Guidelines: The entry delay time and Burg Alarm Comm Delay (field *88) combined cannot exceed 1 minute. *12 Exit Delay #2 (partition-specific) Enter 03-15 multiplied by 15 seconds. 00 = no delay. Exit Delay #2 is used for a secondary door requiring a longer delay than those assigned to Exit Delay #1. NOTE: The delay may not exceed 60 seconds for UL installations. SIA Guidelines: The delay must be set for a minimum 45 seconds. *13 Alarm Sounder Duration (partition-specific) Enter 01-15 multiplied by 2 minutes. 00 = no timeout. Defines the length of time the Bell Output and the keypad’s sounder will sound for all audible alarms. Must be minimum 16 minutes for UL Commercial Burglary installations. SIA Guidelines: Must be minimum 6 minutes. Burglary or RS232 Input 0 = burglary 1 = RS232 input If enabled, sets terminal 23 (high side (+) of zone 9) as an RS232 input. This enables the system to receive serial data (75 baud) via terminal 23. UL Using the RS232 input for automation is not permitted in UL installations. *14 *15 Keyswitch Assignment Enter 1-8 partition keyswitch is being used. Enter 0 if the keyswitch is not used. The keyswitch requires the use of zone 7 wired loop (zone 7 is no longer available as protection zone). The fire and panic alarm voltage triggers (J7) automatically become ARMING and READY status outputs for the Keyswitch LEDs. Openings/closing report as user “0” if enabled in field *40. *16 Confirmation of Arming Ding (partition-specific) 0 = disable 1 = enable If enabled, produces ½-second external alarm sounding (“ding”) at the end of exit delay (or after kissoff from the central station, if sending closing reports). Must be 1 for UL installations. *17 AC Loss Keypad Sounding 0 = disable 1 = enable If enabled, sounding at the keypad (rapid beeping) occurs when AC power is lost (sounding occurs about 2 minutes after actual AC loss). *19 Randomize AC Loss Report 0 = disable 1 = enable If enabled, randomizes AC loss reporting between 10 and 40 min. after an actual AC loss. If disabled, AC loss reporting about 2 minutes after actual AC loss. Selecting this option helps prevent an overload of AC loss messages at the central station during a community blackout. FIELD TITLE and DATA ENTRIES EXPLANATION Section 5 – Data Field Descriptions 5-3 *20 VIP Module Phone Code 1-9 = first digit of access code ∗∗∗∗ or # = second digit of access code (enter # +11 for “∗”, or # +12 for “#”) To disable enter 00 for the 1st digit If a 4285/4286 Voice Module is being used, enter the 2-digit phone code used to access the system. Must be disabled for UL installations. *21 Prevent Fire Timeout 0 = disable (timeout) 1 = enable (no timeout) If enabled, there is no timeout of the alarm sounder duration for all fire zones, regardless of partition, so that fire sounding continues until the system is reset. If disabled, (timeout) the normal burglary sounder duration (field ✳13) applies to fire alarms. *22 Keypad Panic Enables (partition- specific) 0 = disable 1 = enable If enabled, the keypad panics (zones 995, 996, and 999) may be used in this partition. There are 3 entries in this field, one for each panic. *23 Multiple Alarms (partition- specific) 0 = disable 1 = enable If enabled, allows more than one alarm sounding for a given zone during an armed period. NOTE: that multiple alarm soundings will not occur more frequently than allowed by the programmed alarm sounder duration. This has no impact on the number of communication messages transmitted. Must be 1 for UL installations. *24 Ignore Expansion Zone Tamper 0 = disable (tamper detection) 1 = enable (no tamper detection) If disabled, the system monitors the tampers on expansion zones. NOTE: Only applicable to certain polling loop sensors with tamper switches or 5800 Series transmitters. Must be 0 for UL installations. *25 Burglary Trigger for Response Type 8 0 = disable 1 = enable If enabled, allows triggering of Output 3 (pin 7) of the J7 header to include zone response type 8 (24-hr. auxiliary). *26 Intelligent Test Report 0 = disable 1 = enable If enabled, no test report is sent if any other type of report was sent since the last test report. If disabled, test reports are sent at the set intervals, regardless of whether or not any other report has been sent. Must be 0 for UL applications. *27 Test Report Interval Enter 0001-9999 for the test report interval in hours. Enter 0000 for test reporting. If a test report is desired, enter a test code in Report Code Programming in #93 Menu Mode. Set first test report time in field *83. Maximum Test report interval is 0024 for UL installations. *28 Power-Up in Previous State 0 = disable 1 = enable If enabled, the system, upon power-up, reverts to its status prior to a complete power loss. If disabled, the system always powers up in a disarmed state. NOTE: Neither authority level 0 nor 5 can be used to disarm the system if the control powers up armed. Must be 1 for UL applications. *29 Quick Arm (partition-specific) 0 = disable 1 = enable If enabled, allows arming of the burglary system in AWAY, STAY, INSTANT, or MAXIMUM mode by using the [#] key instead of the user code. NOTES: When armed, the system reports closing as User 0 if Open/Close reporting for User #2 (typically a Master level user) was enabled for a given partition. If Quick Arm is used, the Installer Code and Authority Level 5 codes cannot disarm the system. FIELD TITLE and DATA ENTRIES EXPLANATION VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-4 TouchTone or Rotary Dial 0 = disable 1 = enable Select the dialing method for the system If you select TouchTone, make sure the subscriber has requested and is paying for TouchTone service. Note that whether or not TouchTone dialing for call placement is permitted, communication by the use of DTMF signaling (ADEMCO High Speed) will still take place. See field 1*33 for TouchTone w/Rotary backup *30 *31 PABX Access Code Enter 00-09; B-F (11-15) This field is used to enter up to four 2-digit numbers representing the prefix needed to obtain an outside telco line. If not required, enter nothing and proceed to next field. *32 Primary Subscriber’s Account Number (partition-specific) Enter 00-09; B-F (11-15) Enter a 3- or 4-digit (depending on report format) primary subscriber account number. Each number requires a 2-digit entry so as to allow entry of hexadecimal digits (B-F). If a 3-digit account number is to be used, enter data only in the first 3 locations, and enter * in the fourth location. *33 Primary Phone Number Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause. Enter the primary central station phone number, up to 17 digits. This is the phone number the control will use to transmit Alarm and status messages to the central station. Do not fill unused spaces. NOTE: Backup reporting is automatic only if a secondary phone number is entered. *34 Secondary Phone Number Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause. Enter the secondary phone number, up to 17 digits. The secondary phone number is used if communication on the primary number is unsuccessful, or if split/dual reporting is desired. Do not fill unused spaces. NOTE: If this field is programmed, a secondary subscriber account number (field *90) must also be programmed. *35 Download Phone Number Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause. Enter the downloading phone number, up to 17 digits. Do not fill unused spaces. NOTE: This field is applicable only if downloading is utilized. *36 Download ID Number Make entries as 2-digit numbers as follows: 00=0 01=1 02=2 03=3 04=4 05=5 06=6 07=7 08=8 09=9 10=A 11=B 12=C 13=D 14=E 15=F Enter eight digits. NOTE: This field is applicable only if downloading is utilized. *37 Download Command Enables 0 = disable 1 = enable Enabling a function means that you are able to perform that function via the ADEMCO Compass Downloading software. Functions are as follows: Dialer Shutdown; System Shutdown; Not Used; Remote Bypass; Remote Disarm; Remote Arm; Upload Program; Download Program. For UL installations, all entries must be 0. *38 Prevent Zone XXX Bypass (partition-specific) Enter a zone number (001-250). Enter 000 if all zones can be bypassed. Enter three digits for zone that cannot be bypassed by the user. NOTES: The actions manual bypass, group bypass, auto-stay, and STAY/INSTANT arming modes cannot bypass any zone programmed in this field. The system will not arm if the zone is programmed with the vent zone or force arm fault attributes. *39 Enable Open/Close Report for Installer Code (partition-specific) 0 = disable 1 = enable If enabled, whenever the Installer Code is used to arm or disarm the partition, an open/close report is sent to the central station. FIELD TITLE and DATA ENTRIES EXPLANATION Section 5 – Data Field Descriptions 5-5 *40 Enable Open/Close report for Keyswitch 0 = disable 1 = enable If enabled, whenever the keyswitch is used to arm or disarm the partition, an open/close report is sent to the central station. *41 Normally Closed or EOLR (Zones 2-8) 0 = EOLR used 1 = normally closed If 0, end-of-line resistors must be used on zones 2-8. If 1 end-of-line resistors cannot be used and only normally closed devices must be used. Must be 0 for UL installations. *42 Dial Tone Pause Enter the wait time for dial tone detection: 0 = 5 seconds; 1 = 11 seconds; 2 = 30 seconds. Enter the time the system waits for dial tone before dialing. Applies if true dial tone is not selected in field *43. Must be 0 for UL installations. *43 Dial Tone Detection 0 = disable 1 = enable If enabled, the system waits for true dial tone. If no dial tone is detected, control dials at end of pause programmed in field *42. If disabled, the system pauses for seconds entered in field *42, then dials. NOTE: Disabling may be necessary in high-noise environment telco networks where noise can be confused with dial tone, resulting in premature dialing. *44 Ring Detection Count Enter 00 to disable ring detection. Enter 01-14 for ring counts of 1-14. Enter 15 to select Answering Machine Defeat Mode Only applicable if using a 4285/4286 VIP Module and/or if station-initiated downloading will be used. NOTES: Do not enter 00 if a 4285/4286 is installed. In the Answering Machine Mode, the caller should let the phone ring once, then hang up, and call again within 30 seconds. The system, upon hearing one ring followed by nothing, does not answer the first call, but readies itself to pick up on the first ring of the next incoming call that is received within 30 seconds (i.e., the downloader calling again). Must be 00 for UL installations. *45 Primary Format 0=Low Speed; 1=Contact ID; 2=ADEMCO High Speed; 3=ADEMCO Express Enter the reporting format for the primary telephone number. *46 Low Speed Format (Primary) 0 = ADEMCO Low Speed 1 = Sescoa/Radionics Enter the low speed format for the primary telephone number. *47 Secondary Format 0=Low Speed; 1=Contact ID; 2=ADEMCO High Speed; 3=ADEMCO Express Enter the reporting format for the secondary telephone number. *48 Low Speed Format (Secondary) 0 = ADEMCO Low Speed 1 = Sescoa/Radionics Enter the low speed format for the secondary telephone number. *49 Checksum Verification Enter 2 digits, one for the primary and one for the secondary. 0 = disable 1 = enable If enabled, the system for either or both primary/secondary formats sends a verification digit to validate the message at the receiver without having to send two message rounds. Selection is valid for 3+1, 4+1, and 4+2 reports. *50 Sescoa/Radionics Select 0 = Radionics 1 = Sescoa Radionics selection uses hexadecimal 0-9, B-F reporting. Sescoa selection uses only numeric reporting (0-9). NOTE: The selection applies to both primary and secondary phone numbers. FIELD TITLE and DATA ENTRIES EXPLANATION VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-6 *51 Dual Reporting 0 = disable 1 = enable If enabled, all reports are to be sent to both primary and secondary phone numbers. NOTE: If used with Split Reporting option 1 (1*34), alarms go to both primary and secondary numbers, while all other reports go to secondary only. If used with Split Reporting option 2, alarms go to both lines, open/close and test messages go to secondary only, while all other reports go to primary. *52 Standard/Expanded Reporting Primary 0 = disable 1 = enable This field has six entries as follows: Alarm, Restore, Bypass, Trouble, Open/Close, Low Battery. If enabled, expanded reports are sent to the primary phone number if low speed format is selected in field *45. NOTE: Expanded overrides 4+2 format. *53 Standard/Expanded Reporting Secondary 0 = disable 1 = enable This field has six entries as follows: Alarm, Restore, Bypass, Trouble, Open/Close, Low Battery. If enabled, expanded reports are sent to the secondary phone number if low speed format is selected in field *47. NOTE: Expanded overrides 4+2 format. *54 Unattended Mode 0 = disable 1 = enable If enabled, the system automatically calls the downloader at programmed intervals. NOTE: The following fields must be programmed first: primary subscriber account number – field *32; primary phone number – field *33; downloader phone number – field *35. Or you can go into the Unattended Program Mode, from normal operating mode, by entering Installer Code + [#] + [8] + [9]. *56 Dynamic Signaling Delay Enter 00-15 times 15 seconds. Select the time the panel should wait for acknowledgment from the first reporting destination before it attempts to send a message to the second destination (first and second destinations are determined in field ✳57). NOTE: If the acknowledgment is received before the delay time expires, no message is sent to the second destination. *57 Dynamic Signaling Priority 0 = Primary Dialer 1 = Long Range Radio Select the initial reporting path for central station messages. *58 Long Range Radio Central Station #1 Category Enable 0 = disable 1 = enable This field has six entries as follows: Alarm, Trouble, Bypass, Open/Close, System, Test. If enabled, the reports are sent to the primary subscriber ID of the Long Range Radio. *59 Long Range Radio Central Station #2 Category Enable 0 = disable 1 = enable This field has six entries as follows: Alarm, Trouble, Bypass, Open/Close, System, Test. If enabled, the reports are sent to the secondary subscriber ID of the Long Range Radio. *79 Zone Type Restores for Zone Types 1-8 0 = disable 1 = enable This field has eight entries, one for each zone type. Select the zone types that will send Restore reports. *80 Zone Type Restores for Zone Types 9, 10 and 16 0 = disable 1 = enable This field has three entries, one for each zone type. Select the zone types that will send Restore reports. *83 First Test Report Time Enter 00-07the for day (01 = Monday) Enter 00-23 for the hour Enter 00-59 for the minutes Enter the day and time that the first Test report shall be transmitted. Enter 00 in all locations if the Test report is to be sent immediately upon exiting. Enter 00 in the day location if the report is to be sent at the next occurrence of the time that is set. FIELD TITLE and DATA ENTRIES EXPLANATION Section 5 – Data Field Descriptions 5-7 *84 Swinger Suppression (partition- specific) Enter 01-15. Enter 00 for unlimited reports This option limits the number of messages (alarms or troubles) sent for a specific zone in an armed period. The system automatically resets the shutdown for a zone after 48 hours if there are no trips on any zone. Must be 00 for UL installations. *85 Enable Dialer Reports for Panics & Duress (partition-specific) 0 = disable 1 = enable This field has four entries as follows: Zone 995, 996, 999, Duress Enable for each partition that the panics and duress reporting is desired. NOTE: Non-zero report code must be assigned to zone 992 (duress) to enable Duress reporting. If you enable any of the panics to report, make sure field *22 is programmed correctly for each partition. *87 Entry Warning (partition-specific) 0 = 3 short beeps 1 = slow continuous beeps Select the type of warning for the entry delay period. *88 Burglary Alarm Communicator Delay (partition-specific) 0 = no delay 1 = 30-second delay Select the delay, if any, for burglary alarm communications. Must be 0 for UL installations. SIA Guidelines: Must be 1. *89 Restore Report Timing 0 = instant 1 = after bell timeout 2 = when system is disarmed Select the time when restore reports are sent after an alarm. Must be 2 for UL installations. *90 Secondary Subscriber Account Number (partition-specific) Enter 00-09; B-F (11-15) Enter a 3- or 4-digit (depending on report format) primary subscriber account number. Each number requires a 2-digit entry so as to allow entry of hexadecimal digits (B-F). If a 3-digit account number is to be used, enter data only in the first 3 locations, and enter * in the fourth location. NOTE: This field must be programmed if a secondary phone number is used (field *34). This account number can be the same as the primary account number. 1*07 Check or TRBL Display 0 = CHECK 1 = TRBL Select whether the system should display TRBL or CHECK for trouble conditions. 1*10 First to Alarm Display Lock 0 = scroll alarms 1 = lock display If lock display is selected, the system displays of first fire alarm and requires the user to press the [*] key for a display of each additional fire alarm. Otherwise, the system automatically scrolls all fire alarms. 1*15 Cancel Verify 0 = disable 1 = enable If enabled, the system pulses the alarm output three times and displays “Cancel Sent to Central Station” when it receives a “kissoff” of a Cancel report from the central station This message can only be cleared by entering the code + off. Enter 0 to disable. NOTE: Field 1✳52 determines when a Cancel report is sent to the central station. 1*17 Lobby Partition 0 = none 1-8 = partition number Select the Common Lobby Partition. 1*18 Affects Lobby (partition-specific) 0 = disable 1 = enable If enabled, causes lobby partition to disarm when this partition disarms. NOTE: This partition must be armed before lobby can be armed. FIELD TITLE and DATA ENTRIES EXPLANATION VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-8 1*19 Arms Lobby (partition-specific) 0 = disable 1 = enable If enabled, arming this partition causes the system to attempt to arm the lobby partition automatically. To enable this field, field 1*18 must also be enabled (partition-specific). NOTES: The lobby cannot be armed unless all partitions programmed for “affect” (field 1*18) is already armed. If his field is enabled, Field 1*18 for this partition must also be enabled. Exit Error Logic Enable 0 = disable 1 = enable Exit Error Logic functions as follows: the system at the end of the exit delay, if a door is left open or an interior zone is faulted, starts the entry delay period, and sounds the bell(s), siren(s), and keypad sounders for the duration of entry delay. This gives the user time to re-enter the premises and disarm the system before exit error occurs. If the user does not re-enter the premises and disarm the system, the system bypasses the faulted entry/exit and/or interior zone(s). The rest of the system is armed. In addition, the following dialer reports are sent to the central station if programmed: Exit Error by User (not sent when is using ADEMCO High Speed format) Entry/Exit or Interior Alarm with the zone number Bypass reports NOTE: SIA Guidelines: This field must be enabled. UL Exit Error Logic is not suitable for use in a UL installation. 1*20 Exit Delay Reset 0 = disable 1 = enable If enabled, when the panel is armed, the normal exit delay begins. After the user exits, closes the door and then re-enters the premises, the exit delay time is reset to the programmed value. NOTES: Exit Delay Reset is designed to allow an operator to re-enter the premises to retrieve a forgotten item without triggering an alarm. This feature may only be activated once after arming. SIA Guidelines: The Exit Delay must be enabled. UL Exit Delay Reset is not suitable for use in a UL installation. 1*21 Cross-Zoning UL Cross Zoning is not suitable for use in a UL installation. Cross Zoning is designed so that a combination of two zones must be faulted within a 5-minute period of each other (whereas the first zone remains faulted, when the second zone trips) to cause an alarm on either zone. This prevents momentary faults from one of the zones from causing an alarm condition. You can select four "sets" of cross-zones (programmed in data fields 1*22, 1*23, 1*24, and 1*25), keeping in mind the following: • Both zones in each set must protect the same area. • When cross-zoning motion sensors, both device's areas of protection must be situated so that both units will trip at the same time if their shared protected area is violated. • Both zones in each set must be in the same partition. • A fire zone must only be crossed to another fire zone protecting the same physical area (see warning below). DO NOT cross-zone a fire zone with a burglary zone under any circumstance. Cross a fire zone with another fire zone only, and BOTH must be protecting the same physical area (no walls or partitions separating them). Consult NFPA 72 standard for exact spacing requirements. We recommend that spacing between fire cross- zones be no farther than 30 ft. Section 5 – Data Field Descriptions 5-9 Conditions That Affect Cross-Zone Operation • If one of the zones in a pair is bypassed or has a zone response type set to 0, the cross-zoning feature does not apply. • If an entry/exit zone is paired with an interior follower zone, be sure to enter the entry/exit zone as the first zone of the pair. This ensures that the entry delay time is started before the follower zone is processed. • If a relay is programmed to activate on a fault of one of the zones, the relay activates without the other zone being faulted. • If a relay is programmed to activate on either an alarm or trouble, both zones must trip before the relay will activate, and both zones must restore for the relay to deactivate (if relay is programmed to deactivate on a Zone List Restore). If the one of the zones trips and the second zone does not trip within the 5-minute period, an “error” message is reported to the central station. The Contact ID event code is 378. FIELD TITLE and DATA ENTRIES EXPLANATION 1*22 Cross Zoning Pair One Enter 001-250 Enter 000,000 to disable Select the first pair of cross zones, which must both be faulted within a five- minute period to cause an alarm. Must be 000,000 for UL installations. 1*23 Cross Zoning Pair Two Enter 001-250 Enter 000,000 to disable Select the second pair of cross zones, which must both be faulted within a five- minute period to cause an alarm. Must be 000,000 for UL installations. 1*24 Cross Zoning Pair Three Enter 001-250 Enter 000,000 to disable Select the third pair of cross zones, which must both be faulted within a five- minute period to cause an alarm. Must be 000,000 for UL installations. 1*25 Cross Zoning Pair Four Enter 001-250 Enter 000,000 to disable Select the fourth pair of cross zones, which must both be faulted within a five- minute period to cause an alarm. Must be 000,000 for UL installations. 1*26 Panic Button or Speedkey For A, B, C keys: 00 = panic function 01-32 = macro number For D key: 00 = to select a macro to execute when key is pressed 01-32 = macro number Select for the A, B, and C keys whether the system performs a panic or a speedkey function when the key is pressed. Select for the D key whether the system performs a specific macro or if the user will select a macro when the key is pressed. NOTES: If using the A, B, and C, keys for panic alarms, verify fields *22 and *85 are programmed correctly. If a user code with global arm/disarm is used to execute the macro, the user’s global capabilities will override any arm/disarm commands in the macro sequence. 1*28 RF Transmitter Low Battery Sound 0 = disarmed state only 1 = both armed and disarmed states Select when the RF transmitter low-battery condition should display and audible beep annunciate on the keypad. Must be 1 for UL installations. FIELD TITLE and DATA ENTRIES EXPLANATION VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-10 1*29 RF Transmitter Low Battery Reporting 0 = disable 1 = enable If enabled, the system sends a Trouble message for RF transmitter low-battery condition to the central station. NOTE: The Trouble message will be sent for a transmitter supervision failure, independent of this selection. Must be 1 for UL. 1*30 RF Receiver Supervision Check- in Interval Enter 02-15 times 2 hours (4-30 hours). 00 = disable receiver supervision. Select the check-in monitoring interval for the RF receiver(s). Failure of a receiver to receive any RF signal within the time entered results in the activation of the response type programmed for zone 990 for the first receiver and zone 988 for the second receiver and their related communication reports. Maximum is 2 (4 hr) for UL installations. 1*31 RF Transmitter Check-in Interval Enter 02-15 times 2 hours (4-30 hours). 00 = disable transmitter supervision. Select the check-in monitoring interval for the RF transmitters. Failure of an individual transmitter to send a supervision signal within the time entered will result in a trouble response and related communication report. Maximum is 2 (4 hr) for UL. 1*33 TouchTone with Rotary Backup 0 = disable 1 = enable If enabled, the system reverts to rotary dialing if communicator is not successful in dialing using TouchTone DTMF on first attempt. 1*34 Communicator Split Reporting 0 = Split Reporting disabled 1 = Alarm, Alarm Restore, and Cancel reports to primary, all others to secondary 2 = Open/Close and Test reports to secondary, all other reports to primary Select the type of split reporting for system communication. NOTE: See *51 for split/dual reporting combinations. 1*35 Access Control Dialer Enables 0 = disable 1 = enable There are six entries for this field as follows: Trace, Trouble, Not Used, Bypass, System, Alarm. If Trace is enabled, access grant/denial events sent to the central station. For the other events, if enabled, a report is sent to the central station. 1*42 Call Waiting Defeat 0 = disable 1 = enable If enabled, the system defeats Call Waiting on the first outgoing call attempt to both the primary and secondary numbers. NOTES: After the panel's initial call to report the alarm, the panel may attempt to make an additional call, perhaps for a cancel or a zone restoral. If Call Waiting is not defeated, an operator at the central station attempting to contact the premises (to verify whether the alarm is valid) hears the phone ringing indefinitely and must to dispatch on the call. DO NOT enable this feature unless Call Waiting is being used. 1*43 Permanent Keypad Display Backlighting (partition-specific) 0 = disable 1 = enable If enabled, backlighting for the keypad display remains on at all times. Otherwise the backlighting comes on when a key is pressed. NOTE: When a key is pressed, display backlighting turns on for all keypads in that partition. 1*44 Wireless Keypad Tamper Detect 0 = disable 1 = enable If enabled, when more than 40 key depressions are received without a valid sequence (arm, disarm, etc.), the control panel disables the wireless keypad. The inhibit is removed once a valid key sequence is received from a wired keypad. FIELD TITLE and DATA ENTRIES EXPLANATION Section 5 – Data Field Descriptions 5-11 1*45 Exit Delay Sounding (partition- specific) 0 = disable 1 = enable If enabled, the system produces slow beeping from the keypads during exit delay and reverts to rapid beeping during the last 10 seconds of the exit delay. NOTE: The duration of the beeping is the programmed value of field *10 regardless of which entry/exit zone is used to exit the premises. SIA Guidelines: Exit Delay Sounding must be enabled. See page 32 in the Programming Guide, “SOUND OPTION”, prompt for disabling the entry/exit beeps on individual keypads. 1*46 Auxiliary Output Mode 0 = ground start output. 1 = smoke detector reset. 2 = keypad sounds at an auxiliary sounder. 3 = AAV module. Select the mode for output 1 on the J7 triggers. NOTES: Only one of the options may be active within the system. Option 2 is available in the VISTA-128BP only. Option 2 applies only to the partition enabled in field *15. 1*47 Chime on External Siren (partition-specific) 0 = disable 1 = enable If enabled, the system produces chime annunciation on the external alarm sounder. 1*48 Wireless Keypad Assignment 0 = none 1-8 = partition number Select the partition in which RF keypad is used. 1*49 Suppress Transmitter Supervision Sound 0 = disable 1 = enable If enabled, no trouble soundings occur on the keypad for transmitter check-in failures. Must be 0 for UL. 1*52 Send Cancel If Alarm + Off (partition-specific) 0 = disable 1 = enable If enabled, Cancel reports are sent when the system is disarmed after an alarm, regardless of how much time has gone by. If disabled, Cancel reports are sent within Bell Timeout period only. NOTE: This option must be enabled so Cancel reports are always sent. 1*53 Disable Download Callback 0 = callback required 1 = no callback required Select whether a callback from the control panel is required for downloading. Must be 0 for UL installations. 1*55 European Date Format 0 = disable (mm/dd/yy) 1 = enable (dd/mm/yy) Select the date format for display in the event log. 1*56 AC 60Hz or 50Hz 0 = 60Hz 1 = 50Hz Select the frequency for the AC. Must be set to 0 for U.S. and Canadian installations. 1*57 Enable 5800 RF Button Global Arm 0 = disable 1 = enable If enabled, the system arms/disarms in accordance with the button’s user’s global arming settings. 1*58 Enable 5800 RF Button Force Arm 0 = disable 1 = enable If enabled, allows the RF button user to force a bypass of all faulted zones when arming the system. NOTE: When attempting to arm the system, the keypad beeps once after the button is pressed if any faulted zones are present. The user should then press the button again within 4 seconds to force-bypass those zones and arm the system. FIELD TITLE and DATA ENTRIES EXPLANATION VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-12 1*60 Zone 5 Audio Alarm Verification 0 = disable 1 = enable If enabled, zone 5 is used for 2-way audio (AAV). Must be 0 for UL installations. NOTE: Zone 5 cannot be used as protection zone. 1*69 Printer Type 0 = parallel printer 1 = serial printer Select the printer type for the event log printout. NOTE: if you are using a parallel printer connected to the VA8201 Alpha Pager Module. 1*70 Event Log Types 0 = disable 1 = enable This field has five entries as follows: Alarm, Check, Bypass, Open/Close, System. If enabled, the system logs those events into the event log. NOTE: Events are also logged into the PassPoint system, if installed. 1*71 12/24 Hour Type Stamp Format 0 = 12-hour 1 = 24-hour Select the type of time stamping for the event log. 1*72 Event Log Printer On-Line Mode 0 = disable 1 = enable If enabled, the system prints the events as they occur. If disabled, the system prints the log only upon request. 1*73 Printer Baud Rate 0 = 1200 1 = 300 Select the baud rate for the serial printer. NOTE: Must be 1 if using the alphanumeric pager interface. 1*74 Relay Timeout XXX Minutes Enter 000-127 times 2 minutes (000-254). This is used for #80 Menu Mode Time-Driven event relay command numbers “04/09” and Output Programming in the #93 Menu Mode Programming output command “56.” 1*75 Relay Timeout YYY Seconds Enter 000-127 seconds. This is used for #80 Menu Mode Time-Driven event relay command numbers “05/10” and Output Programming in the #93 Menu Mode Programming command “57.” 1*76 Access Control Relay (partition- specific) 01-96 = relay number 00 = relay not used. If enabled, the assigned relay closes for 2 seconds when the user enters his code and presses 0. Must be 00 for UL installations. NOTE: See SECTION 3: Installing the Control for enhanced access control capabilities. 2*00 Number of Partitions Enter 1-8. Enter the number of partitions used in the system. 2*01 Daylight Saving Time Start/End Month 0 = disable 1 = enable Enter the months (00-12) in which daylight saving time starts and ends. Enter 00, 00 if daylight saving time does not apply to the user’s region. Standard setting for U.S. is 04,10. 2*02 Daylight Saving Time Start/End Weekend 0 = disable 1 = enable Enter the start and end weekends for daylight saving time as follows: 1=first; 2=second; 3=third; 4=fourth; 5=last; 6=next to last; 7=third from last. Standard setting for U.S. is 1,5. UL Fields 2*05 – 2*08 must be set to 0 for UL installations. FIELD TITLE and DATA ENTRIES EXPLANATION Section 5 – Data Field Descriptions 5-13 2*05 Auto-Arm Delay (partition- specific) 00 = no delay. 01-14 times 4 minutes (04-56) delay. 15 = no auto arming. This is the time between the end of the arming window and the start of auto-arm warning time (field 2*06). 2*06 Auto-Arm Warning Period (partition-specific) 01-15 times 1-minute warning. 00 = no warning period. This is the time that the user is warned by a keypad sounding and display to exit the premises prior to auto arming of the system. 2*07 Auto-Disarm Delay (partition- specific) 00 = no delay. 01-14 times 4 minutes (04-56) delay. 15 = no auto disarming. This is the time between the end of the disarming window and the start of auto disarming of the system. 2*08 Force Arm Enable for Auto-Arm (partition-specific) 0 = disable 1 = enable If enabled, the system automatically bypasses any faulted zones when it attempts to auto-arm. If disabled, the system will not auto-arm. 2*09 Open/Close Reports by Exception (partition-specific) 0 = disable 1 = enable If enabled, Open/Close reports are sent only if the openings/closings occur outside the arm and disarm windows. NOTES: Open reports are also suppressed during the closing window in order to prevent false alarms if the user arms the system, then re-enters the premises, for example to retrieve a forgotten item. Openings and closings are still recorded in the event log. This field must be set to 1 if No Opening and No Closing reports are to be sent. 2*10 Allow Disarming Only During Arm/Disarm Windows (partition- specific) 0 = disable 1 = enable If enabled, disarming of the system is allowed only during the arming/disarming windows, or if the system is in alarm (if 2*11 is set to 1). NOTE: This applies only to Operator-level users. Installer, Master, and Manager-level users can disarm the system at any time. 2*11 Allow Disarm Outside Window if Alarm Occurs 0 = disable 1 = enable If enabled, allows the system to be disarmed outside the programmed disarm (opening) window if an alarm has occurred. Otherwise disarming is allowed only during the disarm window. NOTE: Used only if field 2*10 is enabled. 2*18 Enable GOTO for this Partition (partition-specific) 0 = disable 1 = enable If enabled, this partition can be accessed from another partition’s keypad using the GOTO command. 2*19 Use Partition Descriptor 0 = disable 1 = enable If enabled, the normal keypad display will include a partition number and four- digit descriptor. 2*20 Enable J7 Triggers for Partition (partition-specific) 0 = disable 1 = enable If enabled, the J7 triggers function for this partition. FIELD TITLE and DATA ENTRIES EXPLANATION VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-14 2*21 Supervision Pulses for LRR 0 = disable 1 = enable There are three entries in this field as follows: Fire, Burglary/Audible Panic, Silent Panic/Duress. If enabled, causes the control to send periodic short pulses on the J7 radio triggers to the LRR. The LRR uses these pulses to determine that its connection to the control is still intact. Must be 1 for UL installations. 2*22 Display Fire Alarms of Other Partitions (partition-specific) 0 = disable 1 = enable If enabled, allows fire alarms that occur on other partitions to be displayed at this partition’s keypad(s). 2*23 Display Burglary & Panic Alarms for Other Partitions (partition- specific) 0 = disable 1 = enable If enabled, allows burglary and panic alarms that occur on other partitions to be displayed at this partition’s keypad(s). 2*24 Display Troubles of Other Partitions (partition-specific) 0 = disable 1 = enable If enabled, allows troubles that occur on other partitions to be displayed at this partition’s keypad(s). 2*30 Pager Installed 0 = disable 1 = enable Enable if the alphanumeric pager interface is installed. 2*31 Delay Paging 0 = disable 1 = enable This field has eight locations, one for each pager. If enabled, the system waits the delay time specified in field 2*32 before transmitting the message after the dialer completes sending the message. 2*32 Time to Delay Pager After Dialer 000-024 times 10 seconds (010-240). This delay should be set to allow enough time for the central station to call back the premises in order to verify an alarm condition. Field 2*31 must be enabled. 2*33 Pager 1 Phone Number Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause. Enter the paging service phone number for Pager 1. Enter up to 17 digits. Do not fill unused spaces. 2*34 Pager 1 ID Number Enter 0-9 Enter the Pager ID number for Pager 1. Enter up to 10 digits. 2*35 Pager 1 Format 0 = numeric 1 = ID 2 = alphanumeric Enter the pager format for Pager 1. 2*36 Pager 1 Delay 1 000-060 seconds. This delay occurs after the phone number is dialed and before the pager ID is sent, giving the pager system time to answer the phone call. NOTE: Program only if using numeric format. 2*37 Pager 1 Delay 2 000-060 seconds. This delay occurs after the pager ID is sent and before the event information is sent. NOTE: Program only if using numeric format. FIELD TITLE and DATA ENTRIES EXPLANATION Section 5 – Data Field Descriptions 5-15 2*38 Pager 1 Partition Enable 0 = disable 1 = enable This field has eight entries, one for each partition. If enabled, the system sends messages to Pager 1 for the partition(s). 2*39 Pager 1 Trigger Event Enables 0 = disable 1 = enable This field has five entries as follows: Alarm, Trouble, Bypass, Open/Close, System. If enabled, the system sends a signal to the pager. 2*40 Pager 2 Phone Number Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause. Enter the paging service phone number for Pager 2. Enter up to 17 digits. Do not fill unused spaces. 2*41 Pager 2 ID Number Enter 0-9 Enter the Pager ID number for Pager 2. Enter up to 10 digits. 2*42 Pager 2 Format 0 = numeric 1 = ID 2 = alphanumeric Enter the pager format for Pager 2. 2*43 Pager 2 Delay 1 000-060 seconds. This delay occurs after the phone number is dialed and before the pager ID is sent, giving the pager system time to answer the phone call. NOTE: Program only if using numeric format. 2*44 Pager 2 Delay 2 000-060 seconds. This delay occurs after the pager ID is sent and before the event information is sent. NOTE: Program only if using numeric format. 2*45 Pager 2 Partition Enable 0 = disable 1 = enable This field has eight entries, one for each partition. If enabled, the system sends messages to Pager 2 for the partition(s). 2*46 Pager 2 Trigger Event Enables 0 = disable 1 = enable This field has five entries as follows: Alarm, Trouble, Bypass, Open/Close, System. If enabled, the system sends a signal to the pager. 2*47 Pager 3 Phone Number Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause. Enter the paging service phone number for Pager 3. Enter up to 17 digits. Do not fill unused spaces. 2*48 Pager 3 ID Number Enter 0-9 Enter the Pager ID number for Pager 3. Enter up to 10 digits. 2*49 Pager 3 Format 0 = numeric 1 = ID 2 = alphanumeric Enter the pager format for Pager 3. 2*50 Pager 3 Delay 1 000-060 seconds. This delay occurs after the phone number is dialed and before the pager ID is sent, giving the pager system time to answer the phone call. NOTE: Program only if using numeric format. 2*51 Pager 3 Delay 2 000-060 seconds. This delay occurs after the pager ID is sent and before the event information is sent. NOTE: Program only if using numeric format. FIELD TITLE and DATA ENTRIES EXPLANATION VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-16 2*52 Pager 3 Partition Enable 0 = disable 1 = enable This field has eight entries, one for each partition. If enabled, the system sends messages to Pager 3 for the partition(s). 2*53 Pager 3 Trigger Event Enables 0 = disable 1 = enable This field has five entries as follows: Alarm, Trouble, Bypass, Open/Close, System. If enabled, the system sends a signal to the pager. 2*54 Pager 4 Phone Number Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause. Enter the paging service phone number for Pager 4. Enter up to 17 digits. Do not fill unused spaces. 2*55 Pager 4 ID Number Enter 0-9 Enter the Pager ID number for Pager 4. Enter up to 10 digits. 2*56 Pager 4 Format 0 = numeric 1 = ID 2 = alphanumeric Enter the pager format for Pager 4. 2*57 Pager 4 Delay 1 000-060 seconds. This delay occurs after the phone number is dialed and before the pager ID is sent, giving the pager system time to answer the phone call. NOTE: Program only if using numeric format. 2*58 Pager 4 Delay 2 000-060 seconds. This delay occurs after the pager ID is sent and before the event information is sent. NOTE: Program only if using numeric format. 2*59 Pager 4 Partition Enable 0 = disable 1 = enable This field has eight entries, one for each partition. If enabled, the system sends messages to Pager 4 for the partition(s). 2*60 Pager 4 Trigger Event Enables 0 = disable 1 = enable This field has five entries as follows: Alarm, Trouble, Bypass, Open/Close, System. If enabled, the system sends a signal to the pager. 2*61 Pager 5 Phone Number Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause. Enter the paging service phone number for Pager 5. Enter up to 17 digits. Do not fill unused spaces. 2*62 Pager 5 ID Number Enter 0-9 Enter the Pager ID number for Pager 5. Enter up to 10 digits. 2*63 Pager 5 Format 0 = numeric 1 = ID 2 = alphanumeric Enter the pager format for Pager 5. 2*64 Pager 5 Delay 1 000-060 seconds. This delay occurs after the phone number is dialed and before the pager ID is sent, giving the pager system time to answer the phone call. NOTE: Program only if using numeric format. 2*65 Pager 5 Delay 2 000-060 seconds. This delay occurs after the pager ID is sent and before the event information is sent. NOTE: Program only if using numeric format. FIELD TITLE and DATA ENTRIES EXPLANATION Section 5 – Data Field Descriptions 5-17 2*66 Pager 5 Partition Enable 0 = disable 1 = enable This field has eight entries, one for each partition. If enabled, the system sends messages to Pager 5 for the partition(s). 2*67 Pager 5 Trigger Event Enables 0 = disable 1 = enable This field has five entries as follows: Alarm, Trouble, Bypass, Open/Close, System. If enabled, the system sends a signal to the pager. 2*68 Pager 6 Phone Number Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause. Enter the paging service phone number for Pager 6. Enter up to 17 digits. Do not fill unused spaces. 2*69 Pager 6 ID Number Enter 0-9 Enter the Pager ID number for Pager 6. Enter up to 10 digits. 2*70 Pager 6 Format 0 = numeric 1 = ID 2 = alphanumeric Enter the pager format for Pager 6. 2*71 Pager 6 Delay 1 000-060 seconds. This delay occurs after the phone number is dialed and before the pager ID is sent, giving the pager system time to answer the phone call. NOTE: Program only if using numeric format. 2*72 Pager 6 Delay 2 000-060 seconds. This delay occurs after the pager ID is sent and before the event information is sent. NOTE: Program only if using numeric format. 2*73 Pager 6 Partition Enable 0 = disable 1 = enable This field has eight entries, one for each partition. If enabled, the system sends messages to Pager 6 for the partition(s). 2*74 Pager 6 Trigger Event Enables 0 = disable 1 = enable This field has five entries as follows: Alarm, Trouble, Bypass, Open/Close, System. If enabled, the system sends a signal to the pager. 2*75 Pager 7 Phone Number Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause. Enter the paging service phone number for Pager 7. Enter up to 17 digits. Do not fill unused spaces. 2*76 Pager 7 ID Number Enter 0-9 Enter the Pager ID number for Pager 7. Enter up to 10 digits. 2*77 Pager 7 Format 0 = numeric 1 = ID 2 = alphanumeric Enter the pager format for Pager 7. 2*78 Pager 7 Delay 1 000-060 seconds. This delay occurs after the phone number is dialed and before the pager ID is sent, giving the pager system time to answer the phone call. NOTE: Program only if using numeric format. 2*79 Pager 7 Delay 2 000-060 seconds. This delay occurs after the pager ID is sent and before the event information is sent. NOTE: Program only if using numeric format. 2*80 Pager 7 Partition Enable 0 = disable 1 = enable This field has eight entries, one for each partition. If enabled, the system sends messages to Pager 7 for the partition(s). FIELD TITLE and DATA ENTRIES EXPLANATION VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-18 2*81 Pager 7 Trigger Event Enables 0 = disable 1 = enable This field has five entries as follows: Alarm, Trouble, Bypass, Open/Close, System. If enabled, the system sends a signal to the pager. 2*82 Pager 8 Phone Number Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause. Enter the paging service phone number for Pager 8. Enter up to 17 digits. Do not fill unused spaces. 2*83 Pager 8 ID Number Enter 0-9 Enter the Pager ID number for Pager 8. Enter up to 10 digits. 2*84 Pager 8 Format 0 = numeric 1 = ID 2 = alphanumeric Enter the pager format for Pager 8. 2*85 Pager 8 Delay 1 000-060 seconds. This delay occurs after the phone number is dialed and before the pager ID is sent, giving the pager system time to answer the phone call. NOTE: Program only if using numeric format. 2*86 Pager 8 Delay 2 000-060 seconds. This delay occurs after the pager ID is sent and before the event information is sent. NOTE: Program only if using numeric format. 2*87 Pager 8 Partition Enable 0 = disable 1 = enable This field has eight entries, one for each partition. If enabled, the system sends messages to Pager 8 for the partition(s). 2*88 Pager 8 Trigger Event Enables 0 = disable 1 = enable This field has five entries as follows: Alarm, Trouble, Bypass, Open/Close, System. If enabled, the system sends a signal to the pager. 6-1 SECTION 6 Scheduling Options •••••••••••••••••••••••••••••••••••••••••••••••• • UL • You must program Bypass and Auto-Arm Fail reports for UL installations. • Auto-disarming is not permitted in UL installations. • You must not program Random Scheduling of Time Driven Events for UL installations. General The scheduling features allow certain operations to be automated, such as arming, disarming, bypassing of zones, and activating relay outputs. The system uses time windows (a programmed period of time with a start and stop time) for defining open/close schedules, holiday schedules, user-defined temporary schedules, and access schedules for users. Scheduled events are programmed by user-friendly menu modes of programming (#80, #81, #83, and #93 modes), explained in detail in this section. These menus take you step by step through the options. Auto Arming The system can automatically arm (AWAY Mode) a partition at the end of a pre-determined closing (arming) time window. Auto Arming can be delayed three ways: by use of the Auto-Arm Delay, the Auto-Arm Warning, or by manually extending the closing (arming) time window with a keypad command. The system can also automatically bypass any open zones when auto arming. Auto-Arm Delay Auto-Arm Delay provides a delay (grace period) before auto arming. It starts at the end of the closing time window. The delay is set in 4-minute increments, up to 56 minutes in partition-specific program field 2*05. At the expiration of this delay, the Auto-Arm Warning will start. Auto-Arm Warning The Auto-Arm Warning causes the keypad sounder to warn the user of an impending Auto-Arm. The warning can be set from 1 to 15 minutes prior to the arming in partition-specific program field 2*06. During this period the keypad beeps every 15 seconds and displays “AUTO ARM ALERT.” During the last 60 seconds, the keypads beep every 5 seconds. The panel arms at the conclusion of the Auto-Arm Warning period. Extend Closing Window A user can manually delay the arm (closing) time window by 1 or 2 hours. This is done by entering a keypad command (User Code + #82), which then prompts the user to enter the desired extension time of 1 or 2. This feature is useful if a user must stay on the premises later than usual. The Auto-Arm delay and warning periods begin at the end of the extension. Force Arm The Force Arm option causes the panel to attempt to bypass any faulted zones prior to auto arming (panel performs a force-arm). This option is set in partition-specific program field 2*08. Auto Disarming The system can automatically disarm a partition at the end of a pre-determined opening (disarm) time window. The disarming time can be delayed by using the Auto- Disarm Delay feature. Disarm Delay Auto-Disarm Delay provides a delay before auto disarming. This delay is added to the end of the disarm time window. The delay is set in 4-minute increments, up to 56 minutes, in partition-specific program field 2*07. Restrict Disarming This option allows disarming by users only during the disarm time window and during the arming time window (in case user needs to re-enter premises after manually arming the partition). This option is set in partition-specific field 2*10. If field 2*10 is set, we highly recommend setting field 2*11, as well. This field allows the partition to be disarmed outside the arm/disarm time windows only if the partition is in alarm. VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-2 Exception Reports This option allows the reporting of openings and closings to the central station only if the arming and disarming occurs outside of the predetermined opening and closing time windows. It is set in partition-specific field 2*09. The system can be programmed to send Failed to Open and Failed to Close reports if the partition is not armed or disarmed by the end of the corresponding time window. Limitation of Access of Users by Time A user’s access to the system can be limited to a certain time period. Outside this time, that user’s code is inactive. The system provides up to 8 access schedules, each consisting of two time windows (typically one for opening, one for closing) for each day of the week and two time windows for holidays. The access schedules are programmed in the #80 Menu Mode, and enabled when a user’s access code is added to the system. If a user tries to operate the system outside the schedule, the alpha keypad displays “Access Denied.” Time-Driven Events The system can automatically activate and de-activate relays at predetermined times to turn lights or other devices on and off. The Time-Driven events can be activated at different times in relation to a time window: • At the beginning of a time window • At the end of a time window • During a time window (on at beginning of window, off at end) • At both the beginning and end of the time window (e.g., to sound a buzzer at the beginning and end of a coffee break) • Random time at the start of the time window (occurs within 30 minutes after the start of the time window) • Random time at the end of the time window (occurs within 30 minutes after the end of the time window) • Random during the time window (begins within 30 minutes after the start of the time window and ends within 30 minutes after the end of the time window) The system can perform the same actions on a daily basis, or can perform an action only once (e.g., turn on the porch light this Wednesday at 8:00 PM). The system also provides up to 20 programmable “timers” available to the end user for the purpose of activating output devices at preset times and days. Time Window Definitions Scheduled events are based on time windows, (periods of time) during which an event may take place. The system supports up to 20 time windows, each defined by a “Start” time and a “Stop” time. The windows are shared by all 8 partitions, and are used when programming the various schedules (open/close, limitation of access), as well as for Time- Driven event control. Scheduling Example A store that has the following hours: Monday to Friday 9am to 6pm Saturday 10am to 4pm Sunday Closed Holidays Closed The owner desires the following time windows to allow time for employees to arm or disarm the system: Monday to Friday Open (disarm) 8am to 9am Close (arm) 6pm to 6:30pm Saturday Open (disarm) 9am to 10am Close (arm) 4pm to 4:30pm Sunday & Holidays Closed For this schedule, the four time windows need to be programmed: Window Start Stop Purpose 1 8am 9am Monday-Friday open window 2 9am 10am Saturday open window 3 4pm 4:30pm Saturday close window 4 6pm 6:30pm Monday-Fri. close window Using the #80 Menu Mode, the installer can program open/close schedules by assigning a time window to a day of the week (windows are entered as 2-digit entries) Mon Tue Wed Thu Fri Sat Sun Hol Op/Cl Op/Cl Op/Cl Op/Cl Op/Cl Op/Cl Op/Cl Op/Cl 01/04 01/04 01/04 01/04 01/05 02/03 00/00 00/00 NOTE: 00 is entered for those days on which the store is closed. Employees can arm and disarm the system, when programmed, within the open and close time windows without causing a report to be sent to the central VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-2 station (reporting by exception, field 2*09). The system can be programmed to automatically arm/disarm in case an employee fails to arm/disarm manually (auto-arm/auto-disarm). Open/Close Schedules Definitions General The open/close scheduling is controlled by one of three schedules. Each schedule consists of one time window for openings and one time window for closings. There are three types of schedules available: Daily, Holiday, and Temporary. Daily Schedule Each partition can have one daily schedule consisting of one opening window and one closing window per day. Holiday Schedule A holiday schedule overrides the regular daily schedule on selected holidays throughout the year. The opening and closing windows are programmed in the daily schedule, but the holidays themselves are defined in Holiday Schedule Programming in the #80 Menu Mode. Temporary Schedule The temporary schedule provides a method for the end user to override the daily and holiday schedules. It consists of one opening window and one closing window for each day of the week. The schedule takes effect for up to one week, after which it is automatically deactivated. This schedule is programmed using the #81 Temporary Schedule Menu Mode. Additional Schedules Additional opening and closing schedules can be programmed using the Time-Driven Event Programming. For example, a schedule for normal store openings/closings can be programmed with a daily open/close schedule, and another open/close schedule for a lunch hour can be programmed using the Time-Driven event schedule programming. Refer to “Time-Driven Events” later in this section for detailed information. Open/Close Reports by Exception The system can help reduce communication traffic to the central station by using the Open/Close Reports by Exception feature. The Open/Close by Exception option suppresses these reports from being sent to the central station if an arm or disarm is done within the expected time window. Reports are only sent if the arm or disarm occurs outside the assigned time window. The system keeps a record of all openings/closings in its event log. If a disarming occurs during a closing window (for example, a person who arms the system forgets something and has to re-enter), the Opening report (although outside of the opening window) will not be sent (as long as that disarming occurs within the closing window). This option is programmed in partition-specific program field 2*09. Example of Open/Close Exception Reporting & Scheduling The following chart gives an example of how the Open/Close by Exception reporting works. 6:01PM 5:59AM 6AM 9AM 9:01AM 3:59PM 4PM 6PM 6:01PM 5:59AM Early Opening reports are sent if system is manually disarmed before opening window begins. Early and Late Opening and Closing reports are programmable options in the Report Code Programming. They are not dependent on the programming of the Exception Reporting option. Opening Window No reports are sent if system is disarmed during this time window. If an arming occurs, a Closing report is sent to the central station regardless of how the Exception Reporting option is set. Auto-disarm delay begins. Auto-disarm occurs after delay (if auto-disarm is enabled). Missed Opening reports are sent if manual disarming has not occurred at expiration of opening window. Late Opening reports are sent if disarm occurs after the opening window expires. Early Closing reports are sent if manual arming occurs before the closing window begins. Missed Opening/Closing type reports are programmed in the Report Code Programming. The Exception Reporting option must be set for these to be sent. Closing Window No reports are sent if system is armed* during this time window. * or disarmed if user needs to re-enter premises. Auto-arm delay begins. Auto-arm warning begins. Auto-arm occurs after warning expires (if auto-arm is enabled). Missed Closing reports are sent if manual arming has not occurred at expiration of closing window. Late Closing reports are sent if system is manually armed after the closing window expires. VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-4 Scheduling Menu Mode The #80 Scheduling Menu Mode is used to program most of the scheduling and timed-event options. Enter Installer Code + [#] + [8] + [0] from the normal operating mode. NOTE: Only users with an Installer or Master level user code may enter the #80 mode. The following can be programmed while in this mode: • time windows • open/close schedules to each partition • holiday schedules • Time-Driven events (for system functions and relay activation) • limitation of access schedules Some scheduling features are programmed in Data Field Programming Mode (Installer Code + 8 0 0 0). Some features are programmed in the #93 Menu Mode. The programming scheduling fields are listed below. System-Wide Fields: *04 Enable Random Timers 1*74 –1*75 Relay timeout values 2*01-2*02 Daylight saving time options 2*11 Allow disarming outside window if alarm occurs Partition-Specific fields: 2*05 Auto-arm delay value 2*06 Auto-arm warning time 2*07 Auto-disarm delay value 2*08 Force-arm enable 2*09 Open/Close Reporting by Exception 2*10 Restrict disarm only during windows #93 Menu Mode (System Group #3) Scheduling related report codes Event-driven options are programmed using Output Programming in #93 Menu Mode. Relay activation can also be Time-Driven and that those are programmed using the #80 Menu Mode. Refer to the Time-Driven Event Programming later in this section for the procedure. Steps to Program Scheduling Options This section contains examples of the worksheets only. For complete worksheets, see the Programming Guide accompanying this Installation and Setup Guide. In order to use #80 Scheduling Menu Mode, use the worksheets to do the following: 1. Define time windows (up to 20) 2. Define the daily open/close schedules (one schedule per day, per partition) 3. Define the holidays to be used by the system (up to 16) 4. Define limitation of access times (up to 8 schedules) 5. Define the Time-Driven events (up to 20) NOTE: Temporary schedules are programmed using #81 Menu Mode. Use #80 Scheduling Menu Mode to perform the following functions: 6. Program the time windows 7. Program the open/close schedules 8. Program the Time-Driven events 9. Program the access schedules Scheduling Menu Structure To program schedules, enter Scheduling Program Mode: Installer Code + [#] + [80]. (Installer or Master level user code.) Scheduling Program Mode can be entered only when all partitions are disarmed. There are 6 sections of scheduling menus accessed via #80, as shown below. Entering 1 at a displayed main menu prompt selects that menu section. Prompts for programming that scheduling feature then appear. Enter 0 to skip a section and display the next menu option. PROMPT EXPLANATION Time Window ? 1 = YES 0 = NO 0 Upon entering Schedule Menu Mode, this prompt appears. Enter 1 to program time windows. Refer to Time Windows Programming later in this section for detailed procedures. Enter 0 to move to the “O/C Schedules?” prompt. O/C Schedules ? 1 = YES 0 = NO 0 Enter 1 to program opening and closing schedules. Refer to Open/Close Schedules Programming later in this section for detailed procedures. Enter 0 to move to the “Holidays?” prompt. Section 6 – Scheduling Options 6-5 Holidays ? 1 = YES 0 = NO 0 Enter 1 to program holiday schedules. Refer to Holiday Schedule Programming later in this section for detailed procedures. Enter 0 to move to the “Timed Events?” prompt. PROMPT EXPLANATION Timed Events ? 1 = YES 0 = NO 0 Enter 1 to program timed events for relay outputs, additional schedules, and other system functions. Refer to Time-Driven Event Programming later in this section for detailed procedures. Enter 0 to move to the “Access Sched?” prompt. Access Sched. ? 1 = YES 0 = NO 0 Enter 1 to program access schedules. Refer to Limitation of Access Schedules Programming later in this section for detailed procedures. Enter 0 to move to the “Quit?” prompt. Quit ? 1 = YES 0 = NO 0 Enter 1 to quit #80 Scheduling Menu Mode and return to normal operating mode. Enter 0 to make any changes or review the scheduling programming options. If you press 0, the “Time Window?” prompt is displayed. Time Windows The system provides 20 time windows that are defined with start and stop times. These windows are used for various open/close and access schedules, as well as for output controls, and are the basis of the scheduling system. These windows are shared among all 8 partitions. Time Windows Worksheet The following worksheet is an example of the worksheet found in the Programming Guide. This worksheet will help you define time windows and scheduling aspects of this system before you program them. Note that time windows can span midnight; for example, from 11 PM to 1 AM. Time Window Number Start Time (HH:MM) Stop Time (HH:MM) 1 2 3…..20 A time window must have a start and a stop time. Time Windows Programming Enter Scheduling Mode by entering Installer Code + [#] + [80]. The keypad displays the Time Window Programming prompt. PROMPT EXPLANATION Time Window ? 1 = YES 0 = NO 0 Enter 1 at this main menu prompt to program time windows. Time Window # ? 01-20, 00 = Quit 01 Enter the 2-digit time window number (01-20) to be programmed. Press [✳] to accept the entry. Enter 00 + [✳] at the “Time Window #?” prompt to quit time window programming and display the “Quit ?” prompt. 01 TIME WINDOW 00:00AM 00:00AM If you entered a time window number, the cursor is now positioned on the tens of hours digit of the start of window entry. Enter the desired start of window hour and press [✳]. The cursor moves to the minutes position. Enter the desired minutes and press [✳]. Toggle the AM/PM indication by pressing any key 0-9 while the cursor is under the A/P position and then press [✳]. Repeat this to program the stop of window entry. When the entry is completed, the “Time Window #?” prompt is displayed again. Enter the next time window number to be programmed and repeat the procedure. Quit ? 1 = YES 0 = NO 0 Enter 0 at the Quit ? prompt to return to the main menu choices and continue programming. Enter 1 to quit Scheduling Menu Mode. VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-2 Because the time windows are shared among all partitions, it is important to make sure that changing a time window does not adversely affect desired actions in other partitions. Daily Open/Close Schedules Each partition can be assigned one daily open/close schedule, plus a holiday schedule. Temporary schedules are programmed separately, using the #81 Temporary Schedule Menu Mode. To program additional open/close schedules, see Time-Driven Events Programming later in this section for the procedure. Open/Close Schedule Worksheet The following worksheet is an example of the worksheet found in the Programming Guide. Write the previously defined time window numbers for open and close for each partition. Part Mon Tues Wed Thur Fri Sat Sun Hol Op Cl Op Cl Op Cl Op Cl Op Cl Op Cl Op Cl Op Cl 1 2 3…8 Open/Close Schedule Programming After entering Scheduling Menu Mode, press [0] until the “O/C Schedules?” prompt appears. PROMPT EXPLANATION O/C Schedules ? 1 = YES 0 = NO 0 Enter 1 to program opening and closing schedules. Partition # ? 01-08, 00 = Quit 01 Enter the appropriate partition number for which the following open/close schedules will apply. Enter 00 + [✳] at the “Partition #?” prompt to quit open/close schedules programming and display the “Quit ?” prompt. Mon P1 OP WIND.? 00:00 00:00 00 Enter the time window number 01-20 for the displayed day’s opening schedule beginning with Monday. Enter 00 if no schedule is desired for a particular day. As the number is keyed in, the actual time that has been stored for that window number is displayed as a programming aid. Press [✳] to accept the entry. Mon P1 CL WIND.? 00:00 00:00 00 Enter the time window number for the displayed day’s closing schedule. As the number is keyed in, the actual time that has been stored for the window number is displayed. Press the [✳] key to accept the entry. Tue P1 OP WIND.? 00:00 00:00 00 The keypad now prompts for Tuesday’s open/close schedule. Follow the procedure for Monday’s prompts. When the last day of the week has been programmed, the holiday opening and closing window prompts are displayed. Hol P1 OP WIND.? 00:00 00:00 00 Repeat the procedure for the holiday opening and closing time windows. Press the [✳] key to accept the entry. When the entries are completed, the “Partition #?” prompt is displayed again. Repeat this procedure for each partition in the system. Quit ? 1 = YES 0 = NO 0 Enter 0 at the “Quit ?” prompt to return to the main menu choices and continue programming. Enter 1 to quit Scheduling Menu Mode. 6-1 Holiday Schedules A holiday schedule overrides the regular daily open/close schedule on the programmed holidays throughout the year. The system provides up to 16 holidays that can be assigned for the system. Each holiday can be assigned to any combination of partitions. List the desired holidays in a Month/Day format on the worksheet. Check the partitions for which these holidays apply. Holiday Schedule Worksheet The following worksheet is an example of the worksheet found in the Programming Guide. HOL Partition Month/Day 1 2 3 4 5 6 7 8 1 / 2 / 3…16 Holiday Schedule Programming After entering Scheduling Menu Mode, press [0] until the “Holidays ?” prompt appears. PROMPT EXPLANATION Holidays ? 1 = YES 0 = NO 0 Enter 1 to program holiday schedules. HOLIDAY NUMBER ? 01-16,00=Quit 01 Enter the 2-digit holiday number (01-16) to be programmed and press [✳] to accept entry. Enter 00 + [✳] at the “Holiday Number?” prompt to quit the holiday menus and display the “Quit ?” prompt. 01 ENTER DATE 00/00 The cursor is now positioned on the tens of months digit. Enter the appropriate month, then press [✳] to proceed to the day field. Enter the appropriate day for the holiday. Press [✳] to accept the entry. Part ? 12345678 Hit 0-8 x x Holidays can be set for any partition, as follows. Press [0] to turn all partitions on or off, or use keys 1-8 to toggle the letter “x” under the partition to which this holiday will apply. Press the [✳] key when all desired partitions have been assigned. The “Holiday Number?” prompt is displayed again. Repeat the procedure for each holiday to be programmed. Quit ? 1 = YES 0 = NO 0 Enter 0 at the “Quit ?” prompt to return to the main menu choices and continue programming. Enter 1 to quit Scheduling Menu Mode. Time-Driven Events These schedules are used to activate outputs, bypass zones, etc. based on time. There are 20 of these schedules that may be programmed for the system, each governed by the previously defined time windows. The actions that can be programmed to automatically activate at set times are: relay commands, arm/disarm commands, zone bypassing commands, and open/close access conditions. Time-Driven Events Worksheet The following worksheet is an example of the worksheet found in the Programming Guide. Fill out the worksheet using the steps outlined below. Automatic Refresh Feature The system automatically updates the status of all Time-Driven Events upon any of the following occurrences: • Changing of the time or date via #63 mode • Exiting #80 Scheduling Menu mode • Exiting Program mode • After a disconnect from the downloader • On a power-up • At Daylight Saving Time adjustment. Sched Time Days Action Action Activation VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-2 Num. Window M T W T F S S HDesired Specifier Time 1 2 3…20 1. Enter the schedule number (01-20) and time window number (01-20), and note the day of the week the action is desired. 2. Enter the code for the desired action and action specifier. The action codes represent the events that are to take place when the scheduled time is reached. Each action also requires an action specifier, which defines what the action will affect (relay, relay group, partition, zone list, user group). The action specifier varies, depending on the type of action selected. The following is a list of the Action Codes (desired actions) used when programming Time-Driven events. Note that these codes are independent of the relay codes programmed during Output Programming in the #93 Menu Mode. Relay Commands Action Code Action Action Specifier 01 Relay On Relay # 02 Relay Off Relay # 03 Relay Close for 2 seconds Relay # 04 Relay Close XX minutes (set in field 1*74) Relay # 05 Relay Close YY seconds (set in field 1*75) Relay # 06 Relay Group On Relay Group # 07 Relay Group Off Relay Group # 08 Relay Group Close for 2 seconds Relay Group # 09 Relay Group Close XX minutes (set in field 1*74) Relay Group # 10 Relay Group Close YY seconds (set in field 1*75) Relay Group # Arm/Disarm Commands Action Code Action Action Specifier 20 Arm-STAY Partition(s) 21 Arm AWAY Partition(s) 22 Disarm Partition(s) 23 Force Arm STAY (Auto- bypass faulted zns) Partition(s) 24 Force Arm AWAY (Auto- bypass faulted zns) Partition(s) 25 Arm INSTANT Partition(s) 26 Arm MAXIMUM Partition(s) • The auto-arm warning (field 2*06) applies when using Time-Driven events to auto-arm. • Temporary schedules do not override an auto-arming or auto-disarming programmed in Time-Driven events. • The auto-arming window cannot be extended using the Installer Code + #82 Mode. Bypass Commands Action Code Action Action Specifier 30 Auto bypass – Zone list Zone list # 31 Auto unbypass – Zone list Zone list # Open/Close Windows Action Code Action Action Specifier 40 Enable Opening Window by partition Partition(s) 41 Enable Closing Window by partition Partition(s) 42 Enable Access Window for access group Access Group Access Control Commands Action Code Action Action Specifier 55 Access Point Grant Access Point # 56 Access Point Grant with Override Access Point # 57 Access Point Protect Access Point # 58 Access Point Bypass Access Point # 59 Access Point Lock Access Point # 60 Access Point Exit Access Point # 61 Access Point Group Grant Group # 62 Access Point Group Grant with Override Group # 63 Access Point Group Protect Group # 64 Access Point Group Bypass Group # 65 Access Point Group Lock Group # 66 Access Point Group Exit Group # 67 Access Point Partition Grant Partition # 68 Access Point Partition Grant with Override Partition # 69 Access Point Protect by Partition Partition # 70 Access Point Bypass by Partition Partition # 71 Access Point Lock by Partition Partition # 72 Access Point Exit by Partition Partition # 73 Access Point Trigger On Trigger # 74 Access Point Trigger Off Trigger # 77 Access Point Group Enable Group # 78 Access Point Group Disable Group # Section 6 – Scheduling Options 6-9 3. Enter the desired activation time (when the action is to take place). Select from: Activation Time Description 1 Beginning of time window. 2 End of time window. 3 During time window active period only (on at beginning of window, off at end). For example, if bypass is selected to activate during the window, zones in a zone list are bypassed at the beginning of the window and unbypassed at the end of the window. 4 Beginning and end of time window (e.g., a coffee break buzzer). In this example, if relay pulse is selected, the relay pulses for 2 seconds at the beginning of the window, signaling the beginning of the coffee break. At the end of the window it pulses again, signaling the end of coffee break. 5 Random time at the start of the time window (occurs within 30 minutes after the start of the time window). NOTE: Since the randomization for choice “5” occurs within 30 minutes after the start of the window, the time window must be of a duration of at least 30 minutes. 6 Random time at the end of the time window (occurs within 30 minutes after the end of the time window). 7 Random during the time window (begins within 30 minutes after the start of the time window and ends within 30 minutes after the end of the time window). NOTE: Since the randomization for choice “7” occurs within 30 minutes after the start of the window, the time window must be of a duration of at least 30 minutes. Field *04 must be enabled for randomization. A user must initiate a random schedule by entering one of the following sequences: • [User Code] + [#] + [41]. This will randomize, up to 30 minutes, the activation time of all devices, programmed for randomization, assigned to the partition the sequence is entered in. Enter the sequence again to turn off the random schedule. • [User Code] + [#] + [42]. This is the same as the method above, except the randomization occurs only on devices with activation times within 6 PM and 5 AM. Enter the same sequence again to turn off the random schedule. UL You must not program Random Scheduling of Time Driven Events for UL installations. Time-Driven Event Programming The following menu items must first be programmed in Output Programming in the #93 Menu Mode: Enter Relay No. (reference identification number) Output Group (if applicable) Restriction Output Type (V-Plex, 4204/4204CF, FSA, or X-10) Zone No. (V-Plex) ECP Address (4204/4204CF or FSA) Relay No. (4204/4204CF) LED No. (FSA) House Code (X-10) Unit Code (X-10) After entering Scheduling Menu Mode, press [0] until the “Timed Events ?” prompt appears. PROMPT EXPLANATION Timed Events ? 1 = YES 0 = NO 0 Enter 1 to program timed events. TIMED EVENT # ? 01-20, 00=Quit 01 Enter the timed event number to be programmed (01-20). Press [✳]. The system then prompts the user to enter the desired action to be taken. Enter 00 at the “TIMED EVENT #?” prompt to quit the timed event menus and display the “Quit ?” prompt. VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-10 01 ACTION ? none 00 Enter the action code for this timed-event number from the list at the left. This could be an output command, an arming command, or any other Time-Driven event. Press [✳] to accept the entry. The prompt for the action specifier appears. ACTION CODES EXPLANATION ACTION SPECIFIER 01=Relay On 02=Relay Off 03=Relay Close for 2 seconds 04=Relay Close XX minutes 05=Relay Close YY seconds Actions 01-05 If you selected actions 01-05, the prompt at the right appears. Enter the relay number. Press [✳] to accept entry. The “Time Window ?” prompt appears. 01 RELAY # ? 00 ACTION CODES EXPLANATION ACTION SPECIFIER 06=Relay Group On 07=Relay Group Off 08=Relay Group Close for 2 seconds 09=Relay Group Close XX minutes 10=Relay Group Close YY seconds Actions 06-10 If you selected actions 06-10, the prompt at the right appears. Enter the relay group number. Press [✳] to accept entry. The “Time Window ?” prompt appears. 01 RELAY GRP # ? 00 20=Arm-STAY 21=Arm AWAY 22=Disarm 23=Force Arm STAY 24=Force Arm AWAY 25=Arm INSTANT 26=Arm MAXIMUM 40=Enable Open Window by Part. 41=Enable Close Window by Part. Actions 21-26 and 40-41 If you selected actions 21-26 or 40-41, the prompt at the right appears. Enter the partition to which the action applies. Enter 0 to select all partitions. Enter a partition number again to deselect it. Press [✳] to accept entry. The “Time Window ?” prompt appears. PART? 12345678 HIT 0-8 X X 30=Auto bypass – Zone list 31=Auto unbypass – Zone list Actions 30-31 If you selected actions 30-31, the prompt at the right appears. Enter the zone list number that contains the zones to be bypassed or unbypassed. Press [✳] to accept entry. The “Time Window ?” prompt appears. 01 ZONE LIST ? ENTER 01-15 01 42=Enable Access Window for Access group(s) Action 42 If you selected action 42, the prompt at the right appears. Enter the group number to which the time window will apply. Press [✳] to accept entry. The “Time Window ?” prompt appears. GROUP ? 12345678 HIT 0-8 X 55=Access Point Grant 56=Access Point Grant w/Override 57=Access Point Protect 58=Access Point Bypass 59=Access Point Lock 60=Access Point Exit Actions 55-60 If you selected actions 55-60, the prompt at the right appears. Enter the access point number. Press [✳] to accept entry. The “Time Window ?” prompt appears. 01 ACCESS POINT # 000 61=Access Point Group Grant 62=Access Point Group Grant w/Override 63=Access Point Group Protect 64=Access Point Group Actions 61-66 and 77-78 If you selected actions 61-66, the prompt at the right appears. Enter the group number. Press [✳] to accept entry. The “Time Window ?” prompt appears. 01 GROUP # 00 Section 6 – Scheduling Options 6-11 Bypass 65=Access Point Group Lock 66=Access Point Group Exit 77=Access Point Group Enable 78=Access Point Group Disable ACTION CODES EXPLANATION ACTION SPECIFIER 67=Access Point Partition Grant 68=Access Point Partition Grant w/Override 69=Access Point Protect by Partition 70=Access Point Bypass by Partition 71=Access Point Lock by Partition 72=Access Point Exit by Partition Actions 67-72 If you selected actions 67-72, the prompt at the right appears. Enter the partition to which the action applies. Enter 0 to select all partitions. Enter a partition number again to deselect it. Press [✳] to accept entry. The “Time Window ?” prompt appears. PART? 12345678 HIT 0-8 X X 73=Access Point Trigger On 74=Access Point Trigger Off Actions 73-74 If actions 73-74 were selected, the prompt at the right will be displayed. Enter the trigger number. Press [✳] to accept entry. The “Time Window ?” prompt appears. 01 TRIGGER # 00 01 Time Window ? 00:00 00:00 01 Enter the time window number (01-20) for which this timed event is to occur. As the number is keyed in, the actual time that has been stored for the time window number is displayed. Press [✳] to accept entry. 01 Active time ? 0 Enter the activation time from 1-10 (listed below). As the number is keyed in, the activation time is displayed. The choices are: 1: Trigger at the start of the window. 2: Trigger at the end of the window. 3: Take effect only for the duration of the window. 4: Trigger at both the start and the end of the window. Example: coffee break buzzer. 5: Random trigger, up to 30 minutes, after the start of the window. 6: Random trigger, up to 30 minutes, after the end of the window. 7: Take effect only for the duration of the window, but random start and end the window up to 30 minutes. Press [✳] to accept entry. Days ? MTWTFSSH Hit 0-8 x x The system then asks for which days the event is to be activated. Press 0 to toggle all days on or off; or press keys 1-8 to toggle the letter “x” under the day on or off (Monday = 1, Holiday = H = 8). When all entries have been made, the “TIMED EVENT #?” prompt is displayed again. Repeat the procedure for each timed event for the installation. Quit ? 1 = YES 0 = NO 0 Enter 0 at the “Quit ?” prompt to return to the main menu choices and continue programming. Enter 1 to quit Scheduling Menu Mode. Section 6 – Scheduling Options 6-1 Limitation of Access Schedules Limitation of Access is a means by which a user’s access code is limited to working during a certain period of time. The system provides 8 Access Schedules, each of which consists of two time windows for each day of the week and two time windows for holidays (typically, one for an opening time window and the second for a closing time window). A user, required to follow a schedule, would be assigned to an access group of the same number (e.g., schedule 1= group 1). The user’s access code is assigned to a group when that user is added to the system. If no limitations apply, enter 0. Limitation of Access Schedule Worksheet Enter the appropriate time window numbers for each access schedule. Acc Mon Tues Wed Thurs Fri Sat Sun Hol Sch W1 W2 W1 W2 W1 W2 W1 W2 W1 W2 W1 W2 W1 W2 W1 W2 1 2 3…8 NOTE: The holidays used for the access groups are the same as those defined in the holiday schedule. Limitation of Access Schedules Programming To program access schedules enter Scheduling Menu Mode Installer Code + # 80. After entering Scheduling Menu Mode, press [0] until the “Access Sched. ?” prompt appears. PROMPT EXPLANATION Access Sched. ? 1 = YES 0 = NO 0 Enter 1 to program access schedules. ACCESS SCHED # ? 01-08, 00 = Quit 01 Enter the access control schedule number between 01 and 08. Press [✳] to accept entry. Enter 00 at the “Access Sched #?” prompt to quit the access control menus and display the Quit ? prompt. MON A1 Window 1? 00:00 00:00 00 Enter the first time-window number (01-20) for this access schedule for the displayed day. As the number is keyed in, the actual time that has been stored for the window is displayed. Press [✳] to continue. MON A1 Window 2 ? 00:00 00:00 00 Enter the second time-window number from 01-20 for this access schedule for the displayed day. As the number is keyed in, the actual time that has been stored for the window is displayed. Press [✳] to continue. TUE A1 Window 1? 00:00 00:00 00 Repeat the procedure for the other days of the week. When the last day of the week has been programmed, the windows for holidays may be entered. Hol A1 Window 1 ? 00:00 00:00 00 Enter the first time-window number for holidays for this access schedule. As the number is keyed in, the actual time that has been stored for the window is displayed. Press [✳] to continue. Hol A1 Window 2 ? 00:00 00:00 00 Enter the second time-window number for holidays for this access schedule. As the number is keyed in, the actual time that has been stored for the window is displayed. Press [✳] to continue. Quit ? Enter 0 at the “Quit ?” prompt to return to the main menu choices and continue programming. VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-14 Enter 0 at the “Quit ?” prompt to return to the main menu choices and continue programming. Enter 1 to quit Scheduling Menu Mode. Temporary Schedules Each partition can be assigned a temporary schedule, which overrides the regular open/close schedule (and the holiday schedule). This schedule takes effect as soon as it is programmed, and remains active for up to one week. Only users with the authority level of manager or higher can program temporary schedules. A temporary schedule affects only the partition from which it is entered. Temporary schedules can also be reused at later dates simply by scrolling (pressing [#]) to the “DAYS?” prompt and activating the appropriate days. This should be considered when defining daily time windows. Temporary Schedule Worksheet Partition/Windows Mon Tue Wed Thu Fri Sat Sun 1 Disarm Window Start Time HH:MM Stop Time HH:MM Arm Window Start Time HH:MM Stop Time HH:MM 2…8 Disarm Window Start Time HH:MM Stop Time HH:MM Arm Window Start Time HH:MM Stop Time HH:MM Temporary Schedules Programming Enter User Code + [#] + 81 to enter this mode. PROMPT EXPLANATION Mon DISARM WIND. 00:00AM 00:00AM This prompt is for entering the start and end times of the disarm (opening) window for Monday. Upon entry of this mode, the cursor is positioned on the tens of hours digit of the start time of the disarm window. Enter the desired hour. Press [✳] to move to the minutes field. The minutes are entered in the same manner. Press [✳] to move to the AM/PM position. Pressing any key in the 0-9 range toggles the AM/PM indication. Repeat the procedure for the stop time entry. Press [✳] to store the entries and move to the arming (closing) window for Monday. Pressing [#] scrolls you through the prompts without making any changes. Mon ARM WINDOW 00:00AM 00:00AM This prompt is for entering the start and end times of the arm (closing) window for Monday. The cursor is positioned on the tens of hours digit of the start time of the arm window. Enter the hour. Press [✳] to move to the minutes field. The minutes are entered in the same manner. Press [✳] to move to the AM/PM position. Pressing any key in the 0-9 range toggles the AM/PM indication. Repeat the procedure for the stop time entry. After the windows for that day have been completed, the system prompts for disarm and arm time windows for the next day. Press [#] if no changes are desired. VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-14 Tue DISARM WIND. 00:00AM 00:00AM Repeat the procedure described above for all days of the week. When all the windows for all the days have been completed, the system prompts for which days of the schedule are to be activated. Days ? MTWTFSS Hit 0-7 x x This is the prompt that actually activates the temporary schedule. To select the days to be activated, enter 1-7 (Monday = 1). An “X” appears under that day, indicating the temporary schedule for that day is active. Entering a day’s number again deactivates that day. Pressing 0 toggles all days on/off. The temporary schedule is in effect only for the days highlighted with the letter “x” under them. As the week progresses, the selected days are reset to the inactive state, but all other entries for the temporary schedule remain programmed. Press [✳] to store the entries or press [#] to exit the Temporary Schedule Entry Mode without making any changes. User Scheduling Menu Mode The system provides up to 20 “timers” available to the end user to control output devices. The output devices themselves are programmed into the system by the installer during Output Programming in the #93 Menu Mode. The end user needs only to know the output device number and its alpha descriptor. The installer may set certain outputs to be “restricted” during Output Programming (this prevents the end user from controlling doors, pumps, bell outputs, etc.) To enter this mode, the user enters User Code + [#] + 83. PROMPT EXPLANATION Output Timer # ? 01-20, 00=Quit 01 Enter the output timer number to be programmed (01-20). Press [✳] to accept entry and move to the next prompt. Enter 00 to quit and return to normal operating mode. 06 07:00P 11:45P PORCH LITE 04 If that timer number has already been programmed, a summary screen appears. In this example: 06 = Timer # 07:00PM = Start Time 11:45PM = Stop Time PORCH LITE = Descriptor for Output Device # 4 04 = Output Device # affected by this timer Press [✳] to continue. 06 ENTER OUTPUT# PORCH LITE 04 Enter the desired output number (01-96). As the number is entered, the descriptor for that output device is displayed. Press [✳] to continue. Entering 00 as the output number deletes the timer (Timer 06, in this example) and displays an output descriptor of “None.” Output devices are programmed via #93 Menu Mode. PROMPT EXPLANATION 06 ON TIME ? 07:00 PM The cursor is positioned on the tens of hours digit of the ON time. Enter the desired hour. Press [✳] to move to the minutes field. The minutes are entered in the same manner. The AM/PM indication is toggled by hitting any key from 0-9 while the cursor is under the AM/PM position. Press [✳] to continue. 06 OFF TIME ? 11:45 PM The cursor positioned on the tens of hours digit of the OFF time. Enter the desired hour. Press [✳] to move to the minutes field. The minutes are entered in the same manner. The AM/PM indication is toggled by hitting any key in the 0-9 range while the cursor is under the AM/PM position. Press [✳] to continue. Section 6 – Scheduling Options 6-15 06 DAYS? MTWTFSS HIT 0-7 x x To select the days to be activated, enter 1-7 (Monday = 1). An “x” appears under that day, indicating the output for that day is active. Entering a day’s number again deactivates that day. Pressing 0 toggles all days on/off. The outputs are in effect only for the days highlighted with the letter “x” under them. As the week progresses, the selected days are reset to the inactive state, unless the permanent option is selected (next screen prompt). When completed, press [✳] to continue. 06 Permanent ? 0 = NO,1 = YES 0 Selecting “Permanent” (1) means that this schedule will be in effect on a continuous basis. Selecting 0 means that this schedule will be in effect for one week only. The letter “x” under the day is then cleared, but all other entries for the output device remain programmed. Press [✳] to accept entry. The system quits User Scheduling Mode and returns to normal operating mode. 7-1 SECTION 7 Downloading Primer (Remote Downloading is not a UL Listed feature) •••••••••••••••••••••••••••••••••••••••••••••••• • General Information Downloading allows the operator to remotely access, program, and control the security system over normal telephone lines. Anything that can be done directly from the keypad can be done remotely, using ADEMCO’s COMPASS downloading software. To communicate with the control panel, the following is required: 1. IBM PC-compatible 486 33MHz PC or better with 30 MB of available hard disk space and at least 8MB of RAM (12MB is preferred). Windows 3.X, Windows 95, 98, or Windows NT. 2. One of the following modems: • ADEMCO CIA • Hayes Smartmodem 1200 (external: level 1.2 or higher; internal: level 1.1 or higher) • Hayes Optima 24 + Fax 96 external • Hayes Optima 336 • BizComp Intellimodem 1200 w/volume • BizComp Intellimodem 2400 Other brands are not compatible, even if claimed to be 100% compatible. 3. COMPASS DOWNLOADING software available on CD ROM with a complete User’s Manual. It may also be downloaded from the ADEMCO web page. The web address is http://www.ademco.com. Internal modems must have a 4-position DIP switch. Modems with a 6-position DIP switch will not work. Access Security The following four levels of protection guard the control against compromise while it is being accessed from a remote location: 1. Security code handshake: The subscriber’s account number as well as an 8-digit ID number (known only to the office) must be matched between the control and computer. 2. Hang-up and callback: The control panel “hangs up” and calls the computer back at the pre- programmed number only if the security codes match. 3. Data encryption: All data that is exchanged between the computer and control is encrypted to reduce the possibility of anyone “tapping” the line and corrupting data. 4. Operator access levels: Operators may be assigned various levels of access to the downloader, each having its own log-on code. The access levels allow the operators read/write capabilities of the customers’ account information. For a detailed explanation of the access levels, see the downloading software User Manual. NOTES: • Each time the control panel is accessed successfully, a Callback Requested report is sent to the central station, if Opening reports are programmed. • When the system is downloading, the keypad displays “MODEM COMM.” • After each download or save, an automatic time stamp is done, to indicate the last download (or save) and the operator ID number. • A complete hard copy of each individual account can be obtained by connecting a printer to the computer. Refer to your computer Owner’s Manual or contact your dealer for printer recommendations. Unattended Download Unattended download allows the control panel to communicate with the download computer without an operator at the computer. This feature is useful on new installations. VISTA-128BP/VISTA-250BP Installation and Setup Guide 7-2 The installer can mount the control, attach a keypad and phone line, and continue to wire the rest of the installation while the system is automatically downloaded. The following items must be programmed for unattended download: • The account number (field ✳32) • Primary central station telephone number (field ✳33) • The download telephone number (field ✳35) • Unattended Mode (enable in field ✳54.) NOTE: The default for field ✳54 is enabled (1). Installer Unattended Program Mode The Installer Unattended Program Mode allows the installer to program fields ✳32, ✳33, and ✳35 without entering the normal program mode. Press 0 (NO) or 1 (YES) in response to the displayed menu selection. Pressing 0 displays the next choice in sequence. To access this mode, enter Installer Code + [#] + [89]. The following prompt appears: PROMPT EXPLANATION Unattend. Phone 1 = YES 0 = NO 0 Press 1 to enter the unattended phone number. Unattend. Phone 1 Enter the telephone number of the download software modem. Enter up to 17 digits, 0-9; A key = ✳✳✳✳, B key = #, C key = 2-Sec. Pause. Do not fill unused spaces. Press the ✳ key to accept the phone number and exit. Press the # key to exit without changing any data. The system displays the Quit menu prompt. Press 1 to exit the Installer Unattended Program Mode, or 0 to continue to the next prompt. Unattended Acct# 1 = YES 0 = NO 0 Press 1 to enter the unattended account number. Unattended Acct# 15-15-15-15 Enter a 3-or 4-digit (depending on report format) account number 00-09; B-F (11-15). Each number requires a 2-digit entry so as to allow entry of hexadecimal digits (B-F). If a 3-digit account number is to be used, enter digits in the first 3 locations, and enter 00 in the last location. Press the ✳ to exit without changing any data. The system displays the Quit menu prompt. Press 1 to exit, or 0 to continue. Primary Phone 1 = YES 0 = NO 0 Press 1 to enter the primary phone number. Primary Phone 0 Enter the primary central station telephone number. Enter up to 17 digits, 0-9; A key = ✳, B key = #, C key = 2-Sec. Pause. Do not fill unused spaces. Press the D key accept the phone number and exit. Press the ✳ to exit without changing any data. The system displays the Quit menu prompt. Press 1 to exit, or 0 to continue. Quit ? 1 = YES 0 = NO 0 Enter 1 to quit the Installer Unattended Program Mode. Enter 0 at the “Quit ?” prompt to return to the first menu prompt, “UNATTEND. PHONE”. Trig. Unattended 1 = YES 0 = NO 0 Enter 1 to initiate the unattended download at this time. Otherwise enter 0. NOTE: The ADEMCO Compass Downloader must be in Unattended Mode. An unattended download may be initiated by the installer or end user at any time by entering User Code + [#] + [1]. Section 7 – Downloading 7-3 Getting On-Line with a Control Panel At the protected premises, the control panel must be connected to the existing telephone line (refer to SECTION 3: Installing the Control). No programming of the panel is required before downloading to an initial installation unless you are performing an unattended download. When establishing a connection between the computer and the control panel, the following occurs: Stage What Happens 1 The computer calls up the control panel. (The phone number for each customer must be entered into the customer’s account file on the computer.) 2 The control panel answers the phone call at the pre-programmed ring count and executes a handshake with the computer. 3 The computer sends a request for callback to the control, unless callback is not required. 4 The panel acknowledges the request and hangs up. During the next few seconds, the control processes the request, making sure certain encrypted information received from the computer matches its own memory. 5 Upon a successful match, the control panel seizes the phone line and calls the computer back, unless callback is not required. (The phone number to which the computer’s modem is connected must be programmed into the control field ✳35.) 6 The computer answers, usually by the second ring, and executes a handshake with the panel. 7 The panel then sends other default information to the computer. If this information matches the computer’s information, a successful link is established. The system is now “on-line” with the computer. • Alarms and Trouble responses and reports are disabled during actual uploading or downloading sessions. If you are on-line, but not actively uploading or downloading, all alarms report immediately. All other reports are delayed until you complete the session. • The keypads remain active when on-line with a control, but are inactive during actual uploading or downloading sessions. VISTA-128BP/VISTA-250BP Installation and Setup Guide 7-16 To download a control without programming any information, perform the following steps: Step Action 1 Enter the Installer Code + [#] + [5]. The panel temporarily enables a ring count of 5 and sets the Download Callback option to “1” (callback not required). 2 From the computer, call the panel using the downloader software set to “First Communication” Mode. The downloader establishes a session with no callback. The panel information can then be downloaded. On-Line Control Functions The following functions can be performed while on-line with a control panel (see field *37): • Arm the system in the AWAY Mode; disarm the system • Bypass a zone • Force the system to accept a new program download • Shut down communication (dialer) functions (for nonpayment of monitoring fees in an owned system) • Shut down all security system functions (for nonpayment for a leased system) • Inhibit local keypad programming (prevents takeover of your accounts) • Leave a message for customer NOTE: Messages sent to the control panel from the downloader will be viewable at ALL partitions. • Command the system to upload a copy of its resident program to the office • Read: arming status, AC power status, list of faulted zones, list of bypassed zones, 1000 event log, list of zones currently in alarm, list of zones currently in trouble, and ECP equipment list • Set the real-time clock Scheduled Download The VISTA-128BP/VISTA-250BP can be programmed to periodically and automatically call the downloader. When this option is set up, the system will call the downloader at a scheduled time. Once the connection is established with the modem, the downloader controls which functions are performed (download, arm, upload event log, etc.). The programmable options for the scheduled download are located in the #93 Menu Mode section under the main menu prompt Scheduled Check-in. The options are as follows: • Check-in interval (weekly, monthly quarterly, yearly) • Quarter of the year (if quarterly is selected) • Month of the year (if monthly, quarterly, or yearly is selected) • Day of the month (if monthly, quarterly, or yearly is selected) • Day of the week (if weekly is selected) • Time of day Refer to the #93 Menu Mode section in the Programming Guide for sequence of the prompts. Direct-Wire Downloading The VISTA-128BP/VISTA-250BP can be downloaded without using a modem or telephone line by using a 4100SM Serial Module and Compass Downloading Software. The direct-wire downloading connection is to be temporary, and is not part of the permanent installation. Direct-wire downloading is meant as a tool for the installer during the installation process. The connections between the control and the 4100SM are different than those shown in the 4100SM Installation Instructions. See Figure 7- 1 for the correct connections. In addition, in place of the green wire, referred to in step 2 of the “IN CASE OF DIFFICULTY” section of the 4100SM Instructions, use the violet wire instead. VISTA-128BP/VISTA-250BP Installation and Setup Guide 7-2 Connector J8 on the main PC board (see the Summary of Connections diagram on the inside back cover of this manual) is intended to be interfaced to either a local serial printer (see SECTION 3:Installing the Control) or a computer. Make connections to a computer as shown below. Note that the violet wire connection for a computer differs from that used when connecting a serial printer. Remove the VA8201 Alpha Pager Module, if it is installed, before performing the direct-wire download. It may be reconnected once the direct-wire download is completed. Figure 7-1: Direct-Wire Downloading Connections Telco Handoff Telco handoff is another method of getting on-line with the downloader. The installer or customer enters the User Code + [#] + [1], while on the phone line with the computer’s modem phone line. The customer will get cut-off and the panel and download computer will establish a connection. 8-1 SECTION 8 Setting the Real-Time Clock •••••••••••••••••••••••••••••••••••••••••••••••• • General Information This system provides a real-time clock, which must be set in order for the system’s event log to keep track of events by time and date. It must also be set in order to execute scheduling programs (Time-Driven events). If you are using Panel Linking, you can set the Real- Time clock at one panel and have the system automatically update the time and date at the other control panels. Use a 6139/6160 alpha keypad to set the real- time clock, or set the clock via the downloader software. Only users with Installer or Master authority level can set the clock. Setting the Time and Date To set the real time clock, perform the following steps: Step Action 1 Enter Installer or Master Code + [#] 63. Typical display shows: TIME/DATE –– THU 12:01 AM 01/01/90 The day of the week is automatically calculated based on the date entered. Time and date entries are made by simply entering the appropriate hour, minute, month, day and year. Press [✳] to move the cursor to the right of the display, to the next position. Press [#] to move the cursor to the left of the display, to the previous position. 2 Enter the correct hour. Then press [✳] to move to the “minutes” field. 3 Enter the correct minutes. Press [✳] to move to the AM/PM position. Step Action 4 Press any key 0-9 to change AM to PM, or PM to AM. Press [✳] to move cursor to the “month” field position. 5 Enter the correct month using a 2-digit entry. Press [✳] to move cursor to the “day” field position. 6 Enter the correct day using a 2-digit entry. Press [✳] to move cursor to the “year” field position. 7 Enter the correct year. Press [✳] to continue. 8 The following display appears: Broadcast Time? 1=YES 0=NO 0 If panel linking is being used, enter 1 (YES) to send this time and date setting to all the VISTA-128BP/VISTA-250BP Installation and Setup Guide 8-2 Press [✳] to exit the real-time clock edit mode. 8-3 9-1 SECTION 9 User Access Codes •••••••••••••••••••••••••••••••••••••••••••••••• • General Information The VISTA-128BP allows a total of 150 security access codes to be allocated. The VISTA-250BP allows a total of 250 security access codes to be allocated. Each security access code is identified by a user ID number. Regardless of the number of partitions each code has access to, it occupies only one user slot in the system. If a code is not used in all partitions, that user ID number cannot be used again. The Quick Arm feature can also be programmed (partition-specific program field *29). The Quick Arm feature allows the user to arm the system by pressing the [#] key instead of the security code. The security code must always be entered to disarm the system. • A user code other than the installer code must be programmed in order for the Quick Arm feature to function. • Users 001-050 are the only users that can perform panel linking and are automatically assigned panel linking access. The system is shipped with the following defaults for the user codes: User 4-Digit Code Alpha Descriptor User 1 (Installer) 4140 INSTLR User 2 1234 MASTER User Codes & Levels of Authority Each user of the system can be assigned a level of authority, which authorizes the user for certain system functions. A user can have different levels of authority within different partitions Use the “View Capabilities” keypad function (User Code + [✳] + [✳]) to view the partitions and authority levels for which a particular user is authorized. These levels are described below. Level 0: Installer (User 1) Code • Programmed in field *00 (default = 4-1-4-0). Installer Open/Close reporting selected in field *39. • Can perform all system functions (arm, disarm, bypass, etc.), but cannot disarm if armed by another code (or by Quick Arm). • Can add, delete, or change all other codes, and can select Open/Close reports for any user. • Is the only code that can be used to enter program mode. The Installer Code can be prevented from re-entering the Program Mode by exiting using ∗98. • Must program at least one Master Code during initial installation. Master Codes are codes intended for use by the primary user(s) of the system. Level 1: Master Codes • Can perform all normal system functions. • Can be used to assign up to 148 lower-level codes, which can be used by other users of the system. • Cannot assign anybody a level of 0 or 1. • May change his own code. • Can add, delete, or change Manager or Operator Codes. Each user’s code can be individually eliminated or changed at any time. • Open/Close reporting is automatically the same as that of the Master who is adding the new user. Level 2: Manager Codes • Can perform all system functions (arm, disarm, bypass, etc.) programmed by Master. • May add, delete, or change other users of the system below this level (Manager cannot assign anybody a level of 0, 1, or 2). • May change his own code. • Open/Close reporting is automatically the same as that of the Manager who is adding the new user. Levels 3-5: Operator Codes • Can operate a partition, but cannot add or modify any user code (see table below). Level Title Functions Permitted 3 Operator A Arm, Disarm, Bypass 4 Operator B Arm, Disarm 5 Operator C Arm, Disarm only if armed with same code VISTA-128BP/VISTA-250BP Installation and Setup Guide 9-2 • Operator C (sometimes known as the Babysitter Code) cannot disarm the system unless the system was armed with that code. This code is usually assigned to persons who may need to arm and disarm the system at specific times only (e.g., a babysitter needs to control the system only when babysitting). Level 6: Duress Codes • Sends a silent alarm to a central monitoring station if the user is being forced to disarm (or arm) the system under threat (system must be connected to a central station). • When the system’s Auxiliary Voltage Triggers are connected to another communication’s media (Derived Channel/Long Range Radio), note that duress is signaled on the same trigger that signals silent panic (whereas duress has its own unique report when digitally communicated). • Assigned on a partition-by-partition basis, and can be any code or codes desired. Duress Reporting NOTE: A non-zero report code for zone 992 (duress) must be programmed, and partition-specific field *85 duress location enabled, to enable Duress reporting. • The Duress report-triggering logic activates on the 5th key depression (such as OFF), not the 4th key depression (last digit of code). Duress reports are not triggered if the 5th key is a [*], such as when you perform a GOTO or view the capabilities of a user. General Rules on Authority Levels and Changes The following rules apply to users when making modifications within the system based on the user code authority levels: • Master Codes and all lower-level codes can be used interchangeably when performing system functions within a partition (a system armed with a user’s temporary code can be disarmed with the Master Code or another user’s temporary code), except the Operator Level C Code described above. • A user may not delete or change the user code of the SAME or HIGHER authority than that which he is assigned. • A user (levels 0, 1 and 2 only) may only ADD users to a LOWER authority level. • A user may assign other users access to only those partitions to which he himself has access. • A user code can be DELETED or CHANGED only from within the partition it was created in. • User numbers must be entered in 3 digits. Single-digit user numbers must, therefore, always be preceded by a “00” (e.g., 003, 004, 005, etc.). Make sure the end user understands this requirement. Temporary codes are entered as 4-digit numbers. Open/Close Reporting Note: When a user is added, the system prompts for Open/Close reporting capability only if the installer is adding the new user. When a Master or Manager adds a new user, the new user’s Open/Close reporting is the same as that of the Master or Manager who is adding the user. If Open/Close reports are required to be selectable by the Master or Manager, the Installer should assign two Master or Manager user codes: one with Open/Close reporting enabled, and one without. Note that Open/Close reporting of Quick Arm is enabled if User 002 is enabled for Open/Close reporting, and that Quick Arm reports as User 000. In order for Quick Arm reports to be sent for all partitions, User 002 must have authority and Open/Close must be enabled for all partitions. If a code with access to all partitions is not desired, it is suggested that user 002 be assigned authority level 5 in all partitions, and that the code be kept secret. Authority level 5 cannot disarm the system unless armed by that user. ADEMCO Contact ID format is capable of reporting Users 001-150 uniquely. If any other report format is used, only user numbers 001 – 015 can uniquely report to the central station. Users 016 – 150 will report as User 015. Multiple Partition Access Each user is programmed for a primary (home) partition. A user can also be given access to operate one or more additional partitions. Within each partition, each user may be programmed to have different levels of authority. For example, User 003, the VP of Engineering, could be assigned to work within the Engineering Department (Partition 1) of ABC Manufacturing. Because he needs the full capabilities in his area, he is assigned as a MASTER with Level 1 authority. He must also be able to gain access to the manufacturing area (Partition 2) on an emergency basis. You can set this up easily by requesting that he also be assigned to Partition 2, with a level of authority set lower, such as Level 4 (OPERATOR Level B). The control automatically assigns him the same user number within Partition 2. EXAMPLE OF MULTIPLE PARTITION ACCESS Part 1 Part 2 Part 3 Part 4 Part 5 Part 6 Part 7 Part 8 User 3 User 3 Level 1 Level 4 Master Oper B VISTA-128BP/VISTA-250BP Installation and Setup Guide 9-2 In the above example, User 3 has MASTER authority in Partition 1 and OPERATOR B authority in Partition 2. His user number is the same for both partitions. Note that if a user number is already being used in a partition, the system will automatically assign a new user an unused number. Also notice that no access is allowed for this user into Partitions 3 – 8. Attempts to access these partitions would be denied automatically. Adding a Master, Manager, or Operator Code During user code entry, normal key depressions at other keypads in a partition are ignored. However, panic key depression causes an alarm and terminates user entry. When entering panel link users (001-050) on the local panel, the other remote panels will be prevented from entering panel link user data until the local panel exits User Edit Mode. Enter Installer Code†+ [8] + new user no. (002- 250) + new user’s code †Or Master or Manager Code, but the code must be a higher level of authority than the code being changed (e.g., a Manager Code can add an Operator-level Code, but cannot add a Master or another Manager Code). Keypad prompts for the authority level for this user. NOTE: All references to the number of user codes pertain to the VISTA-250BP. The VISTA- 128BP allows only 150 user codes. PROMPT EXPLANATION User Number = 003 Enter Auth. Level Enter the level number as follows: 1 = Master 2 = Manager 3 = Operator Level A 4 = Operator Level B 5 = Operator Level C 6 = Duress Keypad then prompts for Open/Close reporting option for this user. Open/Close Rep.? 0 = NO , 1 = YES Press 0 (NO) or 1 (YES), depending on whether or not arming/disarming by this user will trigger Opening and Closing reports. This prompt appears only if the Installer Code is used to add a user. Group Bypassing? 0 = NO , 1 = YES Enter 1 (YES) to allow this user to perform group bypasses. Enter 0 (NO) this user will not be able to perform group bypasses. NOTE: In addition to enabling the user for group bypassing, the user must also have access to the partition(s) containing the zones being bypassed and have global arming capability. Access Group? Enter 0-8 If access schedules have been programmed, this prompt appears. Enter the user’s access group number (1-8) if this user should have limited access to the system. Enter 0 if no access group should be assigned. RF Button ? 0=NO , 1=YES If a 5800 Series button transmitter has been enabled for arming/disarming functions, and is not assigned to a user, this prompt appears. Press 0 (NO) or 1 (YES). Enter Button ZN # (001-087) If you answered “yes” to the RF button question, the zone number for the button is requested. Enter any one of the zone numbers assigned to the button transmitter as AWAY, STAY, or DISARM. The system then assigns all buttons of the transmitter to this user number. Multi-Access ? 0 = NO , 1 = YES Press 0 (NO) if the user is to have access to this partition only. Press 1 (YES) if the user is to have access to more than one partition. If NO, the program exits this mode. If YES, the keypad prompts for the Global Arm option for this user. Global Arm ? 0 = NO , 1 = YES Press 0 (NO) or 1 (YES), depending on whether this user will be allowed to arm more than one partition via Global Arm prompts. The keypad now prompts for the user’s access to the next partition. Part. 2 – SHOP ? 0 = NO , 1 = YES Press 0 (NO) or 1 (YES), depending on whether this user will have access to the displayed partition number. If NO, the keypad displays this prompt for the next partition number in sequence. If YES, the keypad prompts for the following: • User’s authority level in the displayed partition (see Authority Level prompt above). VISTA-128BP/VISTA-250BP Installation and Setup Guide 9-4 • Open/Close option for this user in the displayed partition (see Open/Close prompt above). • Global Arm option for this user in the displayed partition. When all partitions have been displayed, the keypad will scroll through all partitions to which access has been assigned, and will display the user number, authority level, open/close and global arm options that were programmed for each partition to which the user was granted access. PROMPT EXPLANATION XMT USER DATA 1 = YES 0 = NO If the user number is from 001-050 this appears. Answer YES (1) to have the system send the user’s attributes to all the other control panels that are “linked” to this control. If you answer NO (0), the system displays the following prompt on the next page. INDV USER PGM 1 = YES 0 = NO Answer YES (1) to link to another control panel and manually enter the user into partition(s) in that control panel. If you answer NO (0), the system scrolls through each partition displaying a summary of the user’s attributes in each partition (see next prompt). Part. 1 A0* WHSE User 003 Auth=3G. Note that the “G” following the authority level indicates that the global arm feature is enabled for this user in the displayed partition, and that the period at the end of the second line indicates Open/Close reporting is enabled for this user in the displayed partition. The “T” indicates the partition from which the user may be changed or deleted. Changing a Master, Manager, or Operator Code Enter Installer Code*+ [8] + new user no. (002-250) + new user’s code *Or Master or Manager Code, but the code must be a higher level of authority than the code being changed (e.g. a Manager Code can add an Operator-level Code, but cannot add a Master or another Manager Code). NOTE: The VISTA-128BP allows only 150 user codes. PROMPT EXPLANATION User Number = 003 NEW USER? The system detects that the user number is already assigned, and prompts if this is a new user. Press 0 (NO). The system then confirms that the change is allowed based on authorization level. Adding an RF Key to an Existing User To add an RF key to an existing user, or to change a user’s global arm option, first delete that user’s code, then re-add the user code as described in the “Adding a Master, Manager, or Operator Code” paragraph. Deleting a Master, Manager, or Operator Code Enter your code*+ [8] + new user no. (002-150) + your code again *Or Master or Manager Code, but the code must be a higher level of authority than the code being changed (e.g. a Manager Code can add an Operator-level Code, but cannot add a Master or another Manager Code). NOTE: The VISTA-128BP allows only 150 user codes. PROMPT EXPLANATION OK TO DELETE 003? 0=NO 1=YES The system prompts to confirm that you want to delete this user. Press 0 (NO) or 1 (YES). If you answered “yes,” that user’s code is removed from all partitions to which it was assigned, and all authorization levels and other information about that user are deleted. Note that a user can be deleted only by a user with a higher authority level. A user cannot delete himself. Section 9 - User Access Codes 9-5 A user code can be deleted only from the partition through which it was entered. If an attempt is made to delete from another partition, the message “User [XXX] Not Deleted” is displayed. Exiting the User Edit Mode Press either [✴] or [#], or don’t press any key for 10 seconds. 10-1 SECTION 10 Testing the System •••••••••••••••••••••••••••••••••••••••••••••••• • Battery Test When AC power is present, the VISTA-128BP/VISTA- 250BP runs a brief battery test every 60 seconds to determine if there is a battery connected, and runs an extended battery test every 4 hours to check on the battery’s condition. If the VISTA-128BP/VISTA-250BP finds that the battery voltage is low (less than approximately 11.5V), it initiates a keypad “SYSTEM LOBAT” display and a rapid keypad beeping sound. It also sends a Low Battery report to the central station (if programmed). The keypad is cleared by entering any security code + OFF, and a Restore report is sent to the central station if the situation has been corrected. Dialer Test The VISTA-128BP/VISTA-250BP may be programmed to automatically transmit test reports to a central station at intervals ranging from once per hour to once per 9999 hours (field ✳27). UL requires the test report to be transmitted at least once every 24 hours. The system can be programmed to send the first report at any time of the day, or on any day of the week (field ✳83). Burglary Walk-Test (Code + [5] TEST) This test causes the system to sound keypad beeps in response to faults on zones for the purpose of allowing proper zone operation to be checked without triggering alarms. This test can be activated by any-level user by entering the corresponding security code and pressing TEST while the burglary portion of the system is disarmed. UL requires that this test be conducted on a weekly basis. When this test is first entered, the system activates the alarm output for 3 seconds. The system sends a Start of Walk-Test message to the central station. The keypad displays “Burg Walk Test in Progress” and sounds a single beep every 15 seconds while the test remains active. Open and close each protected door and window in turn. Each action should produce 3 beeps from the keypad. Walk in front of any motion detectors. Listen for three beeps when the detector senses movement. The keypad displays the zone number and alpha descriptor while a door or window remains open or while a detector remains activated. The system automatically issues a Zone 8 Glassbreak Detector Power Reset about 10 seconds after it finds a fault on this zone, to allow faulted detectors to be reset. To end this test, enter any security code and press OFF. An End of Walk-Test message is sent to the central station. The system automatically exits the Test mode if there is no activity (no doors or windows are opened and closed, no motion detectors are activated, etc.) for 30 minutes on the VISTA-128BP, 60 minutes on the VISTA-250BP. The system beeps the keypad(s) twice every 5 seconds during the last 5 minutes as a warning that it is about to exit the Test mode and return to normal operation. Armed Burglary System Test Alarm messages are sent to the central station during the armed system tests. Notify the central station that a test will be in progress. VISTA-128BP/VISTA-250BP Installation and Setup Guide 10-2 A display of “COMM. FAILURE” indicates a failure to communicate (no kissoff by the receiver at the central station after the maximum number of transmission attempts is tried). If this occurs, verify that the phone line is connected, the correct report format is programmed, etc. To perform an armed burglary test, proceed as follows: Step Action 1 Notify the central station that a test of the system is being performed. 2 Arm the system. 3 Fault one or more zones. 4 Silence alarm sounder(s) each time by entering the code and pressing OFF. NOTE: The system must be rearmed after each code + off sequence. 5 Check that entry/exit delay zones provide the assigned delay times. Step Action 6 Check the keypad-initiated alarms, if programmed, by pressing the panic key pairs (✳ and #, 1 and ✳, and/or 3 and #). The word ALARM and a descriptor “999” are displayed for ✳ and #. If [1] and [✳] are pressed, “995” is displayed; if [3] and [#] are pressed, “996” is displayed. 7 If the system has been programmed for audible emergency, the keypad emits a loud, steady alarm sound. Silence the alarm by entering the security code and pressing OFF. If the system has been programmed for silent panic, there are no audible alarms or displays. A report is sent to the central station, however. 8 Notify the central station that all tests are finished, and verify results with them. Testing Wireless Transmitters Transmitter ID Sniffer Mode Use the Transmitter Sniffer Mode to test that transmitters have all been properly programmed. If a transmitter does not have its serial number “enrolled,” it will not turn off its zone number. To enter the Transmitter ID Sniffer Mode, proceed as follows: Step Action 1 Enter Installer Code + [#] + [3]. The keypad displays all zone numbers of wireless units programmed into the system. 2 Fault each wireless zone, causing each device to transmit. As the system receives a signal from each of the transmitters, the zone number of that transmitter disappears from the display. 3 Enter Installer Code + OFF to exit the Sniffer Mode. Go/No Go Test Mode Checking the transmitters in this mode assists in determining good mounting locations, and verifies that the RF transmission has sufficient signal amplitude margin for the installed system. • All partitions containing wireless transmitters must be placed in the test mode for sensitivity reduction of the RF receiver (50% sensitivity). Otherwise, the RF receiver remains at full strength. • Make sure that all partitions are disarmed when performing this test, as the wireless receiver gain is reduced in half. To enter the Go/No Go Test Mode, proceed as follows: Step Action 1 Enter Installer Code + [5]. 2 Fault each wireless transmitter, causing each device to transmit. NOTE: If a single receiver is used, the keypad beeps three times to indicate signal reception. If two receivers are used, the keypad beeps once if the first receiver received the signal, twice if the second receiver received the signal, and three times if both receivers heard the signal. 3 If the keypad does not beep, reorient or move the transmitter to another location. Usually a few inches in either direction is all that is required. 4 Enter Installer Code + OFF to exit the VISTA-128BP/VISTA-250BP Installation and Setup Guide 10-2 Go/No Go Test Mode. Trouble Conditions Check or Trouble Messages Display Description CHECK or TRBL (as per field 1✳07) This indicates that a problem exists on the zone number displayed. Zone trouble may be caused by one of the following conditions: • A hardwired fire zone is open (broken wire). • A Day/Night zone (zone type 5) is faulted. • A polling loop zone is not seen by the control panel. • A polling loop zone has been tampered (cover removed on a 4190). • A wireless zone has not checked in during the time programmed in field 1✳31. • A 5800 Series transmitter has been tampered (cover removed). CHECK 6XX XX = 01-32 This indicates a trouble on a 4204CF Supervised Bell Output (corresponding relay number 01-32). CHECK 8XX XX = 00-30 This indicates a trouble on a peripheral device (connected to the panel’s keypad terminals) of the corresponding device address (00-30). CHECK 9XX XX = 00-99 This indicates that a system trouble exists (RF receiver, bell output, etc.). If the problem has been corrected, enter an OFF sequence (Security Code + OFF) twice to clear the display. Power Failure Display Description AC LOSS POWER LED is off This indicates that the system is operating on battery power only. Check to see that the circuit breaker for the branch circuit that your system’s transformer is wired to has not been accidentally turned off. Instruct the user to call a service representative immediately if AC power cannot be restored. Other System Messages Display Description COMM FAILURE This indicates that a failure occurred in the telephone communication portion of your system. LO BAT This indicates that a low-battery condition exists in the wireless transmitter displayed. Pressing any key silences the audible warning sound. SYSTEM LO BAT This indicates that a low-battery condition exists with the system’s backup battery. RCVR SETUP ERROR This indicates that the system has more wireless zones programmed than the wireless receiver can support. If this is not corrected, none of the zones in the system will be protected. If additional wireless zones are desired, use an appropriate receiver. MODEM COMM This indicates that the control is on-line with a remote computer. To the Installer Regular maintenance and inspection (at least annually) by the installer and frequent testing by the user are vital to continuous satisfactory operation of any alarm system. The installer should assume the responsibility of developing and offering a regular maintenance program to the user as well as acquainting the user with the proper operation and limitations of the alarm system and its component parts. Recommendations must be included for a specific program of frequent testing (at least weekly) to ensure the system’s proper operation at all times. Turning the System over to the User Fully explain the operation of the system to the user by going over each of its functions, as well as the User’s Manual supplied. In particular, explain the operation of each zone (entry/exit, perimeter, interior, fire, etc.). Be sure the user understands how to operate any emergency feature(s) programmed into the system. VISTA-128BP/VISTA-250BP Installation and Setup Guide 10-4 Contacting Technical Support PLEASE, before you call Technical Support, be sure you: • READ THE INSTRUCTIONS! • Check all wiring connections. • Determine that the power supply and/or backup battery are supplying proper voltages. • Verify your programming information where applicable. • Verify that all keypads and devices are addressed properly. • Note the proper model number of this product, and the version level (if known) along with any documentation that came with the product. • Note your ADEMCO customer number and/or company name. Having this information handy will make it easier for us to serve you quickly and effectively. You may contact Technical Support via Toll-Free Fax. Please include your return fax number. You will receive a reply within 24 hours. You may also contact Technical Support via modem to ATLIS-BBS, Tech Support’s Electronic Bulletin Board System. Replies are posted within 24 hours. Technical Support:.................................................1-800-645-7492 (8 a.m.-8 p.m. EST) ATLIS-FAX FAXBACK Automated Fax Retrieval System:..................1-800-573-0153 or ............................................................................................1-516-921-6704 / ext. 1667 World Wide Web Address: .......................................http://www.honeywell.com/security A-1 APPENDIX A Regulatory Agency Statements •••••••••••••••••••••••••••••••••••••••••••••••• • UL Installation Requirements The following requirements apply to both UL Residential and UL Commercial Burglary installations: • All partitions must be owned and managed by the same person(s). • All partitions must be part of one building at one street address. • The audible alarm device(s) must be placed where it/they can be heard by all partitions. • The control cabinet must be protected from unauthorized access. This can be done by installing a tamper switch on the cabinet door (not supplied with VISTA-128BP/VISTA-250BP) or by installing a UL Listed passive infrared detector positioned to detect cabinet access. Wire the selected device to any EOLR-supervised zone (Zone 1-8). Program this zone for day trouble/night alarm (type 05) or 24-hour audible alarm (type 07) response. The 24-hour alarm response must be used for multiple-partitioned systems. • Remote downloading and auto-disarming are not UL Listed features. NOTE: UL Commercial Burglary installations require the attack resistant cabinet. The cabinet is included in the VISTA-ULKT kit. UL609 Grade A Local Mercantile Premises/Local Mercantile Safe & Vault Use the following guidelines for a Grade A Local Mercantile Premises/Local Mercantile Safe & Vault installation: • All zones must be configured for EOLR supervision (✳41=0). Wireless sensors may not be used. If 4190WH RPMs are used, set field ✳24 to “0” to enable tamper detection. • Attach a door tamper switch (supplied) to the VISTA-128BP/VISTA-250BP cabinet backbox. For safe and vault installations, a shock sensor (not supplied) must also be attached to the backbox. (Also see SECTION 3: Installing the Control) • Wire an ADEMCO AB12 Grade A Bell/Box to the bell output. Bell wires must be run in conduit. Program the bell output for a timeout of 16 minutes or longer timeout and for confirmation of arming ding. (Also see SECTION 3: Installing the Control.) • Wire the VISTA-128BP/VISTA-250BP tamper switch and AB12 Bell/Box tamper switches to any EOLR-supervised zone (zones 1-8). Program this zone for day trouble/night alarm (type 05) or 24-hour audible alarm (type 07) response. The 24-hour alarm response must be used for multiple-partitioned systems. • Entry delays must not exceed 45 seconds, and exit delays must not exceed 60 seconds. UL365 Police Station Connected Burglar Alarm Follow the instructions for UL609 local installations given above. For Grade A Service: • You may use the VISTA-128BP/VISTA-250BP dialer alone, or the 7720 Long Range Radio alone. • When using the dialer, program it to send Burglary Alarm, Low Battery, and Communicator Test reports. Field ✳27 must be set to “0024” (or less). • If you are using the 7720, connect it to the VISTA-128BP/VISTA-250BP burglary/audible panic alarm trigger. For Grade AA Service: • You must use a 7920SE Long Range Radio. • Connect the 7920SE to the VISTA-128BP/VISTA-250BP burglary/audible panic alarm trigger. VISTA-128BP/VISTA-250BP Installation and Setup Guide A-2 UL611/UL1610 Central Station Burglary Alarm Follow the instructions for UL609 Local installations given above. For Grade A Service: • You must use the VISTA-128BP/VISTA-250BP’ dialer with a 7720 Long Range Radio. • Connect the control’s burglary/audible panic alarm trigger (on J7 header) and the 659EN’s phone line monitor output to the 7720. The 7720 will send a report to the central station when a telephone line fault condition is detected. • Also connect the 7720’s radio fault output to one of the VISTA-128BP/VISTA-250BP’ EOLR-supervised zones (i.e., 1-8). Program this zone for a trouble by day/alarm by night (type 05) or a 24-hour alarm (type 07, 08) response to radio faults. • Program the control’s dialer to send Burglary Alarm, Trouble, Opening/Closing, and Low Battery reports. For Grade AA Service: Follow the instructions for Grade A service, except use the 7920SE in place of the 7720. California State Fire Marshal (CSFM) and UL Residential Fire Battery Backup Requirements The California State Fire Marshal and UL have regulations that require all residential fire alarm control panels to have backup battery with sufficient capacity to operate the panel and its attached peripheral devices for 24 hours in the intended standby condition, followed by at least 4 minutes in the intended fire alarm signaling condition. The VISTA-128BP/VISTA-250BP can meet this requirement without using a supplemental power supply, provided that the panel’s outputs (including the current drawn from the auxiliary power output terminals) are limited as shown below: • Output current is limited to 750mA maximum total auxiliary power, polling loop, and bell output current. • Maximum auxiliary current is 300mA (including polling loop current). • A 14AH battery is used. (Yuasa model NP7-12 recommended; use two connected in parallel.) A dual-battery harness is provided with ADEMCO No. 4100EOLR Resistor Kit (kit also contains EOL resistors having spade lug/heat shrink tubing construction approved by UL and CSFM for fire zone usage). Both batteries fit inside the panel’s cabinet. Appendix A – Regulatory Agency Statements A-3 FEDERAL COMMUNICATIONS COMMISSION (FCC) PART 15 STATEMENT NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. IN THE EVENT OF TELEPHONE OPERATIONAL PROBLEMS In the event of telephone operational problems, disconnect the control panel by removing the plug from the RJ31X (CA38A in Canada) wall jack. We recommend that you demonstrate disconnecting the phones on installation of the system. Do not disconnect the phone connection inside the control panel. Doing so will result in the loss of your phone lines. If the regular phone works correctly after the control panel has been disconnected from the phone lines, the control panel has a problem and should be returned for repair. If upon disconnection of the control panel, there is still a problem on the line, notify the telephone company that it has a problem and request prompt repair service. The user may not under any circumstances (in or out of warranty) attempt any service or repairs to the system. It must be returned to the factory or an authorized service agency for all repairs. FCC PART 68 NOTICE This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that contains, among other information, the FCC registration number and ringer equivalence number (REN) for this equipment. If requested, this information must be provided to the telephone company. This equipment uses the following jacks: An RJ31X is used to connect this equipment to the telephone network. The REN is used to determine the quantity of devices that may be connected to the telephone line. Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of the RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to the line, as determined by the total RENs, contact the telephone company to determine the maximum REN for the calling area. If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. If advance notice is not practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe necessary. The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make the necessary modifications in order to maintain uninterrupted service. If trouble is experienced with this equipment, please contact the manufacturer for repair and warranty information. If the trouble is causing harm to the telephone network, the telephone company may request that you remove the equipment from the network until the problem is resolved. There are no user serviceable components in this product, and all necessary repairs must be made by the manufacturer. Other repair methods may invalidate the FCC registration on this product. This equipment cannot be used on telephone company-provided coin service. Connection to Party Line Service is subject to state tariffs. This equipment is hearing-aid compatible. When programming or making test calls to an emergency number, briefly explain to the dispatcher the reason for the call. Perform such activities in the off-peak hours, such as early morning or late evening. VISTA-128BP/VISTA-250BP Installation and Setup Guide A-4 CANADIAN EMISSIONS STATEMENTS This Class B digital apparatus complies with Canadian ICES-003 NOTICE The Industry Canada Label identifies certified equipment. This certification means that the equipment meets telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to the user’s satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may cause the telecommunications company to request the user to disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines, and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Caution: Users should not attempt to make such connections themselves, but should contact an appropriate electric inspection authority, or electrician, as appropriate. NOTICE: The Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5. AVIS L’étiquette d’Industrie Canada identifie le matériel homologué. Cette étiquette certifie que le matériel est conforme aux normes de protection, d’exploitation et de sécurité des réseaux de télécommunications, comme le prescrivent les documents concernant les exigences techniques relatives au matériel terminal. Le Ministère n’assure toutefois pas que le matériel fonctionnera à la satisfaction de l’utilisateur. Avant d’installer ce matériel, l’utilisateur doit s’assurer qu’il est permis de le raccorder aux installations de l’enterprise locale de télécommunication. Le matériel doit également être installé en suivant une méthode acceptée da raccordement. L’abonné ne doit pas oublier qu’il est possible que la conformité aux conditions énoncées ci-dessus n’empêche pas la dégradation du service dans certaines situations. Les réparations de matériel nomologué doivent être coordonnées par un représentant désigné par le fournisseur. L’entreprise de télécommunications peut demander à l’utilisateur da débrancher un appareil à la suite de réparations ou de modifications effectuées par l’utilisateur ou à cause de mauvais fonctionnement. Pour sa propre protection, l’utilisateur doit s’assurer que tous les fils de mise à la terre de la source d’energie électrique, de lignes téléphoniques et des canalisations d’eau métalliques, s’il y en a, sont raccordés ensemble. Cette précaution est particulièrement importante dans les régions rurales. Avertissement : L’utilisateur ne doit pas tenter de faire ces raccordements lui-même; il doit avoir racours à un service d’inspection des installations électriques, ou à un électricien, selon le cas. AVIS : L’indice d’équivalence de la sonnerie (IES) assigné à chaque dispositif terminal indique le nombre maximal de terminaux qui peuvent être raccordés à une interface. La terminaison d’une interface téléphonique peut consister en une combinaison de quelques dispositifs, à la seule condition que la somme d’indices d’équivalence de la sonnerie de tous les dispositifs n’excède pas 5. B-1 APPENDIX B Summary of System Commands ••••••••••••••••••••••••••••••••••••••••••••••••• • User Code Commands Add A User Code = User Code + 8 + New User Number + New User’s Code Change a Code = User Code + 8 + User Number + New User’s Code Delete a User’s Code = Your User Code + 8 + User Number to Be Deleted + Your Code Again View User Capability = User’s Code + [✳] + [✳] Set Real-Time Clock (Installer, Master Only) = Code + [#] + 63 Programming Commands Site Initiated Download = User Code + [#] + 1. Direct-Wire Download Enable = User Code + [#] + 5. Enter Program Mode = Installer Code + 8000. Enter Interactive Program Mode = Installer Code + 8000 + [#] + 93 Exit Program Mode = ✳99 or ✳98. Event Logging Commands Event Log Display = Code + [#] + 60 (Installer or Master Only) Event Log Print = Code + [#] + 61 (Installer or Master Only) Clear Event Log = Code + [#] + 62 (Installer or Master Only) Wireless System Commands House ID Sniffer Mode = Code + [#] + 2 (Installer Only) Transmitter ID Test = Code + [#] + 3 (Installer Only) Go/No Go Test = Code + 5 (Test Key) Partition GOTO User Code + [✳] + Partition Number 0-8. GOTO Home Partition User Code + [✳] + 0. Panics [✳] + 1 or A Key (Zone 995). [✳] + [#] or B Key (Zone 999). [#] + 3 or C Key (Zone 996). View Downloaded Messages Press 0 for 5 Seconds. Display All Zone Descriptors Press [✳] for 5 Seconds. Additional Commands Display User Self Help Hold Any Key for 5 Seconds. Output Device Control Commands Activate Output Device as Programmed = User Code + [#] + 71. Activate Output Device as Programmed = User Code + [#] + 72. Activate Output Device Manually = User Code + [#] + 70. Activate Output Device or System Event Instantly = User Code + [#] + 77. Randomize Output Devices = User Code + [#] + 41 Randomize Output Devices Programmed with Activation Times Between 6 PM and 5 AM = User Code + [#] + 42. De-activate Randomization = Enter the sequence used to activate randomization. VISTA-128BP/VISTA-250BP Installation and Setup Guide B-2 Scheduling Commands Installer-Programmed Schedule Events = Installer Code + [#] + 80 (Installer or Master Only). Temporary Schedule Editing = User Code + [#] + 81 (Installer, Master, Manager Only). Extend Closing Window = User Code + [#] + 82 (Installer, Master, Manager Only). End User Output Device Programming = User Code + [#] + 83. Access Control Commands Activate Access Relay for Current Partition = User Code + 0. Request to Enter/Exit = User Code + [#] + 73. Request to Enter/Exit at Access Point = User Code + [#] + 74 + Access Point Number. Change Access Point State = User Code + [#] + 75 + Access Point + State. Perform a Test of the VistaKey Module = Installer Code + [#] + 78. Perform an Access Control Card Function = User Code + [#] + 79. Panel Linking Commands Only user 001 – 050 can perform panel linking. Activate Single-Partition, Single-Panel Mode = User Code + [#] + 86. Exit Single-Partition, Single-Panel Mode = User Code + [#] + 85. Activate Multi-Partition, Multi-Panel Mode = User Code + [#] + 87. Exit Multi-Partition, Multi-Panel Mode = Enter [0]. Activate Multi-Panel View Mode = User Code + [#] + 88. Exit Multi-Panel View Mode = Enter [0]. C-1 APPENDIX C Specifications ••••••••••••••••••••••••••••••••••••••••••••••••• • VISTA-128BP/VISTA-250BP CONTROL Physical: Standard Cabinet (included) 12 1/2" W x 14 1/2" H x 3" D UL Cabinet (optional) 14 1/2" W x 18" H x 4.3" D (Included in the VISTA-ULKT kit) Electrical: Voltage Input: From ADEMCO No. 1361 Plug-In Transformer (use 1361CN in Canada) or 1361X10 transformer (for X-10 installations) rated 16.5VAC, 40 VA. Alarm Sounder Output: 10VDC-13.8VDC, 1.7 amps max. (UL1023, UL609 installations); 750mA less aux. current draw (UL985 installations). Auxiliary Power Output: 9.6VDC-13.8VDC, 750mA max. For UL installations, the accessories connected to the output must be UL Listed, and rated to operate in the above voltage range. Backup Battery: 12VDC, 4AH or 7AH gel cell. YUASA NP4-12 (12V, 4AH) or NP7-12 (12V, 7AH) recommended. Standby Time: 4 hours min. with 750 mA aux. load using 7 AH battery. Circuit Protectors: PTC circuit breakers are used on battery input to protect against reverse battery connections and on alarm sounder output to protect against wiring faults (shorts). A solid-state circuit breaker is used on auxiliary power output to protect against wiring faults (shorts). Digital Communicator Formats Supported: ADEMCO High Speed, ADEMCO 4 + 2 Express, ADEMCO Low Speed, ADEMCO Contact ID, Sescoa and Radionics Low Speed Line Seize: Double Pole Ringer Equivalence: 0.7B FCC Registration No.: AC398U-68192-AL-E Remote Keypads 6139 Physical: Width: 6.25 inches Height: 4.75 inches Depth: 1.25 inches Electrical: Voltage Input: 12VDC Current Drain: 100mA Interface Wiring: RED: 12VDC input (+) auxiliary power BLUE: Not Used GREEN: Data to control panel YELLOW: Data from control panel BLACK: Ground and (-) connection from supplemental power supply 6160 Physical: Width: 7.437 inches Height: 5.25 inches Depth: 1.312 inches Electrical: Voltage Input: 12VDC Current Drain: 150mA Interface Wiring: RED: 12VDC input (+) auxiliary power BLUE: Not Used GREEN: Data to control panel VISTA-128BP/VISTA-250BP Installation and Setup Guide C-2 YELLOW: Data from control panel BLACK: Ground and (-) connection from supplemental power supply 6160V Physical: Width: 7 3/8 inches Height: 5 5/16 inches Depth: 1 3/16 inches Electrical: Voltage Input: 12VDC Current Drain: 190mA Interface Wiring: RED: 12VDC input (+) auxiliary power BLUE: Not Used GREEN: Data to control panel YELLOW: Data from control panel BLACK: Ground and (-) connection from supplemental power supply D 1 APPENDIX D Contact ID and Pager Event Codes ••••••••••••••••••••••••••••••••••••••••••••••••• • TABLE OF CONTACT ID EVENT CODES Code Definition 110 FireAlarm 111 SmokeAlarm 121 Duress 122 SilentPanic 123 AudiblePanic 124 DuressAccessGrant 125 DuressEgressGrant 131 PerimeterBurglary 132 InteriorBurglary 133 24-HourBurglary 134 Entry/ExitBurglary 135 Day/NightBurglary 140 ACSZoneAlarm 150 24-HourAuxiliary 301 ACLoss 302 LowSystem Battery 305 SystemReset 306 ProgramTamper 308 SystemShutdown 309 BatteryTestFail 313 SystemEngineerReset 320 ACSRelaySupervision 321 Bell1Trouble 332 PollLoop Short-Trouble 333 ExpansionModuleFailure 338 ACSModuleLowBattery 339 ACSModuleReset 342 ACSModuleACLoss 343 ACSModuleSelf-TestFail 354 ACSRS232Fail 373 FireLoop Trouble 378 CrossZoneTrouble 380 Trouble(global) 381 LossofSupervision(RF) 382 LossofRPMSupervision 383 RPMSensorTamper 384 RFTransmitterLowBattery 389 DetectorSelf-TestFailed 401 O/CbyUser 403 Power-Up Armed/Auto-Arm 406 CancelbyUser 407 RemoteArm/Disarm(Download) CodeDefinition 408 QuickArm 409 KeyswitchO/C 411 CallbackRequested 421 AccessDenied 422 Access Granted 423 DoorForceOpen 424 EgressDenied 425 EgressGranted 426 DoorProp Open 427 AccessPointDSMTrouble 428 AccessPointRTETrouble 429 ACSProgramEntry 430 ACSProgramExit 431 ACSThreatChange 432 AccessPointRelay/TriggerFail 433 AccessPointRTEShunt 434 AccessPointDSMShunt/Unshunt 441 ArmedSTAY 451 EarlyOpen/Close 452 LateOpen/Close 453 FailtoOpen 454 FailtoClose 455 Auto-ArmFail 457 ExitErrorbyUser 459 RecentClose 501 ACSReaderDisable 520 ACSRelayDisable 570 Bypass 576 ACSZoneShunt 577 ACSPointBypass 579 VentZoneBypass 602 CommunicatorTest 606 Listen-IntoFollow 607 BurglaryWalk-Test 621 EventLogReset 622 EventLog50%Full 623 EventLog90%Full 624 EventLogOverflow 625 Time/DateReset 631 ExceptionScheduleChange 632 AccessScheduleChange Event Log and Pager Alpha Descriptors Alpha Event Description FIRE Fire Alarm DURESS Duress Alarm PANIC Silent or Audible Panic Alarm BURGLARY Burglary Alarm EXP SHRT Polling Loop Short RF EXPND Expander Module Failure AUXILIARY Non-burglary Alarm TROUBLE Trouble AC LOSS AC Loss LOW BATTERY System Low Battery SYSTEM RESET System Reset PROG CHANGE Program Change BATTERY FAIL System Battery Failure RF SUPR RF Supervision RPM SUPR RPM Supervision Alpha Event Description RF LBAT RF Low Battery EXP TRBL Expander Module Trouble RF TRBL RF Trouble TAMPER Tamper FIRE TRB Fire Trouble FAIL TO COMM Failure to Communicate BELL TROUBLE Bell Trouble DISARMED Disarmed DISARMED-REM Disarmed Remotely DISARMED-KEY Disarmed Via RF Key DISARM-AUTO Auto-Disarm CALL BACK Callback Requested CANCEL Cancel VISTA-128BP/VISTA-250BP Installation and Setup Guide D 2 DISRMD-EARLY Disarmed Early DISRMD-LATE Disarmed Late Alpha Event Description MISSED DISRM Missed Disarm SKED CHANGE Schedule Change ACC SKED CHG Access Control Schedule Change ARM FAILED Failed to Arm DIALER SHUT Dialer Shutdown SYSTEM SHUT System Shutdown BYPASS Bypass SELF TEST Self-test TEST ENTRY Manual Test Entry TEST EXIT Manual Test Exit LOG 50% FULL Event Log 50% Full LOG 90% FULL Event Log 90% Full LOG OVERFLOW Event Log Overflow LOG CLEARED Event Log Cleared TIME SET Time Set TIME ERROR Time Error PROGRM ENTRY Program Entry PROGRAM EXIT Program Exit Uxxx ADD BY User XXX Added BY Uxxx DEL BY User XXX Deleted BY Uxxx CHG BY User XXX Changed BY PRINTER FAIL Event Log Printer Failure PAGER FAILED Pager Failure TESTED Zone Tested UNTESTED Zone Untested FAILED Zone Test Failed RLY TRBL Relay Trouble EXP TMPR Expansion Module Tamper VENT BYPASS Vent Zone Bypass RF JAM RF Jam Detected JAM RSTR RF Jam Restore FIRE RST Fire Alarm Restore DURE RST Duress Alarm Restore PNC RST Panic Alarm Restore BURG RST Burglary Alarm Restore EXP RST Expansion Module Restore RF RST RF Restore AUX RST Auxiliary Restore MED RST Medical Restore TRBL RST Trouble Restore AC RESTORE AC Restore LOW BATT RST System Low Battery Restore PROG CHANGE Program Change BAT TST FAIL Battery Test Failure RPM RST RPM Restore RFLB RST RF Low Battery Restore EXP RST Expansion Module Failure Restore TMPR RST Tamper Restore FRTR RST Fire Trouble Restore COMM RESTORE Communication Restore RLY RST ECP Relay Trouble Restore ARMED Armed ARMED-STAY Armed Stay ARMED-REM Armed Remotely ARMED-QUICK Quick Armed ARMED-KEY Armed Via RF Key ARMED-AUTO Auto-Armed PARTIAL ARM Partial Armed ARMED-EARLY Armed Early ARMED-LATE Armed Late MISSED ARM Missed Arm DIALER RST Dialer Restore (Shutdown) SYSTEM RST System Restore (Shutdown) Alpha Event Description BYP RST Bypass Restore TEST EXIT Test Mode Exit PRINTER RSTR Printer Restore PAGER RSTR Pager Restore BELL RESTORE Bell Restore EXIT ERR Exit Error RECENT ARM Recent Arm VENT BYP RST Vent Zone Bypass Restore Access Control Events ACS MOD VGM/Access Control Module Failure ACS PNT Access Point Failure DSM SHNT Door Status Monitor Shunt DUR ACCS Duress Access Grant NO ENTRY Access Denied DR OPEN Door Propped Open DR FORCE Door Forced Open ENTERED Access Granted NO EXIT Egress Denied ACPT BYP Access Point Bypass RTE SHNT Request to Exit Shunt EXITED Egress Granted ACLO MOD AC Loss at Module LBAT MOD Low Battery at Module COMM MOD Comm Failure from MLB to Module RES MOD Access Control Module Reset ACPT RLY Access Point Relay Supervision Fail SELF MOD Module Self-Test Failure ACZN CHG Access Control Zone Change ACS PROG Access Control Program Entry ACS PRGX Access Control Program Exit THRT CHG Access Control Threat Change SYS SHUT System Shutdown SYS RST System Engineer Reset ZN SHUNT Access Control Zone Shunt ZN ALARM Access Control Zone Alarm RDR DISA Access Control Reader Disable RLY DISA Access Control Relay/Trigger Disable RTE TRBL Request to Exit Point Trouble DSM TRBL Door Status Monitor Point Trouble DUR EXIT Duress Egress Grant BGN ACS TEST Access Control Test Mode Start MOD RST VGM/Access Control Module Restore ACPT RST Access Point Restore ACRST MOD AC Loss at Module Restore LBAT RST Low Battery at Module Restore COMM RST Comm Fail MLB to Module Restore RLY RST Access Point Relay Supervision Rest SELF RST Self-Test at Module Restore ACPT UNB Access Point Unbypass DSM UNSH Door Status Monitor Unshunt RTE UNSH Request to Exit Point Unshunt DRFO RST Door Forced Open Restore DRPO RST Door Propped Open Restore DSM RST Door Status Monitor Trouble Restore RTE RST Request to Exit Point Trouble Rest RLY ENAB Access Control Relay/Trigger Enable RDR ENAB Access Control Reader Enable ZNAL RST Access Control Zone Restore ZN UNSHT Access Control Zone Unshunt SYSHTRST System Shutdown Restore END ACS TEST Access Control Test Mode End Id 1 Index ••••••••••••••••••••••••••••••••••••••••••••••••• • #93 Menu Mode Programming ..................................4-2 #93 Menu Mode Programming Commands................4-4 12/24 Hour Type Stamp Format..............................5-12 1361 ................................................................3-35, C-1 24-hour Audible Alarm Type 07 .................................4-6 24-hour Auxiliary Alarm Type 08................................4-6 24-hour Silent Alarm Type 06....................................4-6 2-Wire Latching Glassbreak Detectors....................3-10 2-Wire Smoke Detectors...........................................3-7 333 PRM...................................................................3-8 4100SM ...........................................................3-27, 4-9 4100SM Serial Module ..............................................7-4 4101SN Relay Modules...........................................3-18 4197 Polling Loop Extender.....................................3-12 4204 and 4204CF Relay Modules............................3-17 4285/4286 VIP Module............................................3-28 4297 Polling Loop Extender.....................................3-12 4300 transformer ....................................................3-35 4300 Transformer ..........................................3-18, 3-35 4-Wire Smoke Detectors...........................................3-7 5800 Series Transmitters ........................................3-15 5800TM Module......................................................3-15 5869 ................................................................1-2, 3-13 5881 RF Receivers .................................................3-14 5881ENHC.......................................................1-2, 3-13 6139 ........................................................................C-1 6160 ........................................................................C-1 6160V......................................................................C-2 675 Ground Start Module........................................3-18 719...........................................................................3-4 747...........................................................................3-4 7720 .......................................................................3-22 7720ULF.................................................................3-22 7920SE...................................................................3-22 A AAV........................................................................3-30 ABB1031 ..................................................................3-4 AC 60Hz or 50Hz....................................................5-11 AC Loss Keypad Sounding........................................5-2 AC Outlet Ground ...................................................3-36 Access Group..........................................................9-3 Access Control........................................3-25, 3-26, 4-9 Access Control Commands................................6-8, B-2 Access Control Dialer Enables ................................5-10 Access Control of an Entry/Exit Point........................4-9 Access Control of Lighting and Appliances ..............4-10 Access Control Using RF Transmitter......................4-10 ACCESS GRP PGM..................................................4-3 ACCESS POINT PGM ..............................................4-3 Access Point Type 27................................................4-7 Access Relay Number.............................................5-12 Access Schedules.....................................................6-5 Action Code..............................................................6-8 Action Specifier.........................................................6-8 Activation Time.........................................................6-9 Adding a User Code..................................................9-3 Adding an RF Key to a User Code............................9-4 Addressing the Keypads ...........................................3-3 ADEMCO 4+2 Express.............................................3-5 ADEMCO 4+2 EXPRESS..........................................C-1 ADEMCO 4146.......................................................3-19 ADEMCO 685 receiver..............................................3-5 ADEMCO 685 Receiver ..........................................3-30 Ademco AB12...........................................................3-1 ADEMCO CONTACT ID............................................C-1 ADEMCO HIGH SPEED ...........................................C-1 ADEMCO Low Speed ...............................................3-5 ADEMCO LOW SPEED............................................C-1 Affects Lobby.....................................................2-2, 5-7 Agency Statements...................................................A-1 Alarm Output Current Load .....................................3-37 Alarm Output Supervision .........................................3-4 Allow Disarm Outside Window if Alarm Occurs........5-13 Allow Disarming Only During Arm/Disarm Windows.5-13 Alpha Pager Module ........................................3-23, 4-8 ALPHA PROG..........................................................4-3 Antenna Fault .........................................................3-23 Arm/Disarm Commands............................................6-8 Arm-Away Type 21...................................................4-7 Arms Lobby .......................................................2-2, 5-8 Arm-STAY Type 20...................................................4-7 Audio Alarm Verification Module..............................3-30 Auto Arming..............................................................6-1 Auto Disarming.........................................................6-1 Auto-Arm Delay...............................................5-13, 6-1 Auto-Arm Warning....................................................6-1 Auto-Arm Warning Period.......................................5-13 Auto-Disarm Delay..................................................5-13 AUXILIARY OUTPUT ENABLE......................3-18, 3-20 Auxiliary Output Mode.............................................5-11 Auxiliary Power Current Load..................................3-36 B BACK-UP BATTERY.................................................C-1 Battery Capacity Worksheet....................................3-37 Battery Selection Table...........................................3-38 Battery Test............................................................10-1 Bell Timeout..............................................................5-2 Burglary Alarm Communicator Delay.........................5-7 Burglary or RS232 Input............................................5-2 Burglary Trigger for Response Type 8.......................5-3 Burglary Walk Test.................................................10-1 Button RF...............................................................3-16 Button RF (BR) Type 05............................................4-7 Bypass Commands...................................................6-8 C Cabinet Lock.............................................................3-1 California State Fire Marshal (CSFM)........................A-2 Call Waiting Defeat.................................................5-10 Callback....................................................................7-3 Callback Requested..................................................7-1 CANADIAN EMISSIONS STATEMENTS...................A-4 Cancel Verify............................................................5-7 Changing a User Code..............................................9-4 Check Messages ....................................................10-3 Check or TBLE Display.............................................5-7 Checksum Verification...............................................5-5 Chime on External Siren..........................................5-11 CIRCUIT PROTECTORS.........................................C-1 Code + TEST [5].....................................................10-1 Cold Water Pipe......................................................3-36 COMM FAILURE....................................................10-3 Common Lobby.........................................................2-1 Communication Defaults...........................................4-4 Communicator Split Reporting Selection..................5-10 Compass Downloading Software...............................7-4 COMPASS downloading software .............................7-1 Compatible 2-Wire Smoke Detectors.........................3-7 Compatible 4-Wire Smoke Detectors.........................3-7 Compatible 5800 Series Transmitters......................3-16 Compatible Alarm Indicating Devices.........................3-4 Compatible Glass Break Detectors..........................3-10 Compatible Polling Loop Devices.............................3-11 Confirmation of Arming Ding......................................5-2 Console Input (CS) Type 09......................................4-8 Contact ID.................................................................1-3 CONTACT ID EVENT CODES .................................D-1 Contacting Technical Support..................................10-4 Control Unit Power Supply Load..............................3-36 Conventions Used in This Manual ................................vi Cross Zoning Pair Four.............................................5-9 Cross Zoning Pair One..............................................5-9 Cross Zoning Pair Three...........................................5-9 Cross Zoning Pair Two..............................................5-9 Cross-Zoning............................................................5-8 CUSTOM INDEX.......................................................4-3 D Data Encryption........................................................7-1 Data Field Descriptions.............................................5-1 Data Field Programming Mode..................................4-1 Daylight Saving Time Start/End Month....................5-12 Daylight Saving Time Start/End Weekend...............5-12 Deleting a User Code................................................9-4 DEVICE PROG.........................................................4-3 Dial Tone Detection...................................................5-5 Dial Tone Pause........................................................5-5 Dialer Test..............................................................10-1 DIGITAL COMMUNICATOR.....................................C-1 DIP Switch Loop (DP) Type 07..................................4-8 Direct-Wire Downloading...........................................7-4 Disable Download Callback .....................................5-11 Disarm Delay............................................................6-1 Disarm Type 22........................................................4-7 Display Burglary & Panic Alarms for Other Partitions5-14 Display Fire Alarms of Other Partitions....................5-14 Display Troubles of Other Partitions ........................5-14 Door Status Monitor (DSM) Type 11.........................4-8 Download Command Enables ...................................5-4 Download ID Number................................................5-4 Download Phone Number .........................................5-4 Downloading.............................................................7-1 Downloading Access Security ...................................7-1 Downloading Requirements ......................................7-1 Dual Reporting..........................................................5-6 Duress Codes Level 6...............................................9-2 Duress Reporting......................................................9-2 Dynamic Signaling Delay..................................3-22, 5-6 Dynamic Signaling Priority................................3-22, 5-6 E Early Power Detect.................................................3-23 Earth Ground..........................................................3-36 ECP Wire Run........................................................3-21 Enable 5800 RF Button Force Arm..........................5-11 Enable 5800 RF Button Global Arm.........................5-11 Enable Dialer Reports for Panics & Duress ...............5-7 Enable GOTO for this Partition................................5-13 Enable J7 Triggers for Partition...............................5-13 Enable Open/Close Report for Installer Code ............5-4 Enable Open/Close report for Keyswitch...................5-5 Enable Random Timers For Partitions 1-8.................5-1 Entering Programming Mode....................................4-1 Entry Delay #1..........................................................5-2 Entry Delay #2..........................................................5-2 Entry Warning...........................................................5-7 Entry/Exit #1 Type 01................................................4-6 Entry/Exit #2 Type 02................................................4-6 event log........................................................3-23, 3-27 Event Log...................................................1-4, 4-8, 4-9 Event Log and Pager Alpha Descriptors....................D-1 Event Log Printer On-Line Mode.............................5-12 Event Log Types.....................................................5-12 Event Logging Commands........................................B-1 EVENT/ACTION PGM ..............................................4-3 Exception Reports ....................................................6-2 Exit Delay #1............................................................5-2 Exit Delay #2............................................................5-2 Exit Delay Sounding................................................5-11 Exit Error..................................................................1-3 Exit Error Logic Enable .............................................5-8 Exiting the User Edit Mode........................................9-4 EXPERT MODE........................................................4-3 Extend Closing Window ............................................6-1 External Sounders ....................................................3-4 F FCC Part 15 STATEMENT........................................A-3 FCC PART 68 NOTICE.............................................A-3 FCC REGISTRATION NO.........................................C-1 Fire Display Lock......................................................5-7 VISTA-128BP/VISTA-250BP Installation and Setup Guide Index-D-2 Fire With Verification Type 16....................................4-7 First Communication.................................................7-3 First Test Report Time ..............................................5-6 Force Arm.................................................................6-1 Force Arm Enable for Auto-Arm ..............................5-13 Frwd. Power Loss...................................................3-23 FSA Modules ..........................................................3-17 G General Description ..................................................1-1 General Purpose (GP) Type 13.................................4-8 Getting On-Line with a Control Panel.........................7-3 Global Arm ?.............................................................9-3 Go/No Go Test Mode..............................................10-2 Grade A Mercantile Premises Listing.........................3-1 Grade A Mercantile Safe and Vault Listing.................3-2 Grade A Service................................................A-1, A-2 Grade AA Service .............................................A-1, A-2 Ground Start Module...............................................3-18 H Hardwire and Optional Expansion Zones...................1-2 Hardwired (HW) Type 01...........................................4-7 Holiday Schedule ......................................................6-3 Holiday Schedule Programming.................................6-7 Holiday schedules.....................................................6-4 Holiday Schedules.....................................................6-6 Home Automation..........................................3-24, 3-27 House ID Sniffer Mode............................................3-15 How to Use Panel Linking..........................................B-2 I Ignore Expansion Zone Tamper ................................5-3 Installer (User 1) Code Level 0 ..................................9-1 Installer Code............................................................5-1 Installer Unattended Program Mode ..........................7-2 Installing RPM Devices............................................3-11 Installing The Control................................................3-1 Installing the Control's Circuit Board..........................3-2 Intelligent Test Report...............................................5-3 Interior w/Delay Type 10...........................................4-7 Interior, Follower Type 04..........................................4-6 K Keypad Panic Enables ..............................................5-3 Keypads....................................................................2-1 Keyswitch...............................................................3-19 Keyswitch Assignment..............................................5-2 Keyswitch Tamper...................................................3-19 L Limitation of Access..................................................6-2 Limitation of Access Schedules ...............................6-11 Limitation Of Access Schedules Programming.........6-12 LINE SEIZE..............................................................C-1 List of Figures...............................................................v LO BAT..................................................................10-3 Lobby Partition..........................................................5-7 Long Range Radio Central Station #1 Category Enable..................................................................5-6 Long Range Radio Central Station #2 Category Enable..................................................................5-6 Long Range Radio ECP..........................................4-10 Long Range Radio to ECP......................................3-22 Long Range Radio to J7 Triggers............................3-22 Low Speed Format (Primary)....................................5-5 Low Speed Format (Secondary)................................5-5 LRR Battery............................................................3-23 LRR CRC is bad .....................................................3-23 LRR reporting options .............................................3-22 LRR Trouble Messages ..........................................3-23 M Main Logic Board....................................................3-27 Main Logic Board Supervision Type 28 .....................4-7 Manager Codes Level 2............................................9-1 Master Codes Level 1...............................................9-1 Master Keypad.........................................................2-3 MODEM COMM..............................................7-1, 10-3 modems ...................................................................7-1 Momentary Exit Type 29...........................................4-7 Mounting The Control Cabinet...................................3-1 Multi-Access ?..........................................................9-3 Multi-Panel View Mode .............................................2-6 Multi-Partition Multi-Panel Mode................................2-6 Multiple Alarms.........................................................5-3 Multiple Partition Access...........................................9-2 N No Alarm Response Type 23 ....................................4-7 Non-UL Installations..................................................3-4 Normally Closed or EOLR (Zones 2-8)......................5-5 Number of Partitions...............................................5-12 O OC or OPEN CIRCUIT..............................................3-3 On-Line Control Functions........................................7-3 Open/Close Reporting...............................................9-2 Open/Close Reports by Exception....................5-13, 6-3 Open/Close Schedule...............................................6-3 Open/Close Schedule Programming .........................6-6 Open/Close Schedules ......................................6-4, 6-6 Open/Close Windows................................................6-8 Operator Access Levels............................................7-1 Operator Codes Levels 3-5 .......................................9-1 Output Device Control Commands ............................B-1 Output Devices.......................................................3-17 OUTPUT PGM..........................................................4-3 Overvoltage Protection .............................................3-5 P PA400.......................................................................3-4 PABX Access Code...................................................5-4 Pager 1 Delay 1......................................................5-14 Pager 1 Delay 2......................................................5-14 Pager 1 Format.......................................................5-14 Pager 1 ID Number .................................................5-14 Pager 1 Partition Enable..........................................5-15 Pager 1 Phone Number...........................................5-14 Pager 1 Trigger Event Enables.......................5-15, 5-18 Pager 2 Delay 1......................................................5-15 Pager 2 Delay 2......................................................5-15 Pager 2 Format.......................................................5-15 Pager 2 ID Number .................................................5-15 Pager 2 Partition Enable..........................................5-15 Pager 2 Phone Number...........................................5-15 Pager 2 Trigger Event Enables................................5-15 Pager 3 Delay 1......................................................5-15 Pager 3 Delay 2......................................................5-15 Pager 3 Format.......................................................5-15 Pager 3 ID Number .................................................5-15 Pager 3 Partition Enable..........................................5-16 Pager 3 Phone Number...........................................5-15 Pager 3 Trigger Event Enables................................5-16 Pager 4 Delay 1......................................................5-16 Pager 4 Delay 2......................................................5-16 Pager 4 Format.......................................................5-16 Pager 4 ID Number .................................................5-16 Pager 4 Partition Enable..........................................5-16 Pager 4 Phone Number...........................................5-16 Pager 4 Trigger Event Enables................................5-16 Pager 5 Delay 1......................................................5-16 Pager 5 Delay 2......................................................5-16 Pager 5 Format.......................................................5-16 Pager 5 ID Number .................................................5-16 Pager 5 Partition Enable..........................................5-17 Pager 5 Phone Number...........................................5-16 Pager 5 Trigger Event Enables................................5-17 Pager 6 Delay 1......................................................5-17 Pager 6 Delay 2......................................................5-17 Pager 6 Format.......................................................5-17 Pager 6 ID Number .................................................5-17 Pager 6 Partition Enable..........................................5-17 Pager 6 Phone Number...........................................5-17 Pager 6 Trigger Event Enables................................5-17 Pager 7 Delay 1......................................................5-17 Pager 7 Delay 2......................................................5-17 Pager 7 Format.......................................................5-17 Pager 7 ID Number .................................................5-17 Pager 7 Partition Enable..........................................5-17 Pager 7 Phone Number...........................................5-17 Pager 7 Trigger Event Enables................................5-18 Pager 8 Delay 1......................................................5-18 Pager 8 Delay 2......................................................5-18 Pager 8 Format.......................................................5-18 Pager 8 ID Number .................................................5-18 Pager 8 Partition Enable..........................................5-18 Pager 8 Phone Number...........................................5-18 Pager Formats........................................................3-24 Pager Installed........................................................5-14 Paging Service........................................................3-23 Panel Link Module ...........................................2-4, 3-21 Panel Link Module Supervision .................................2-4 Panel Linking.......................................1-3, 2-1, 2-4, 4-8 Panel Linking Commands .........................................B-2 panel linking users.............................................2-4, 9-1 Panic Button or Speedkey.........................................5-9 Partitioned System....................................................2-1 Partitioning........................................................1-3, 2-1 PassPoint Access Control (ACS) Type 10.................4-8 PassPoint Access Control System..........................3-26 PassPoint Dialer Events............................................4-9 Perimeter Type 03....................................................4-6 Peripherals Devices ..................................................1-2 Permanent Keypad Display Backlighting .................5-10 Phone Module Access Code .....................................5-3 PLL out of Lock.......................................................3-23 PLM..........................................................................2-4 polling loop.............................................................3-11 Polling Loop Current Draw ......................................3-36 Polling Loop Supervision.........................................3-12 Power Failure.........................................................10-3 Power Unattained...................................................3-23 Power-Up in Previous State......................................5-3 Prevent Fire Timeout ................................................5-3 Prevent Zone XXX Bypass........................................5-4 Primary Format.........................................................5-5 Primary Phone Number.............................................5-4 Primary Subscriber’s Account Number......................5-4 Printer Baud Rate ...................................................5-12 Printer Configurations.............................................3-27 Printer Type............................................................5-12 Priority of Displays for Panel Linking .........................2-7 Program Modes........................................................4-1 Programming Commands .........................................B-1 PROGRAMMING COMMANDS................................4-1 Programming Entry Errors........................................4-2 Programming Overview.............................................4-1 Programming Partition-Specific Data Fields...............4-2 Programming Scheduling Options.............................6-4 Programming System-Wide Data Fields....................4-2 Q Quick Arm.........................................................5-3, 9-1 Quick Exit.................................................................5-1 R RADIONICS LOW SPEED........................................C-1 Random time............................................................6-9 Randomize AC Loss Report......................................5-2 RCVR SETUP ERROR...........................................10-3 Real-Time Clock.......................................................8-1 Recent Close............................................................1-3 Refresh Feature........................................................6-7 Regulatory Agency Statements.................................A-1 Relay commands......................................................6-8 Relay Timeout XXX Minutes....................................5-12 Relay Timeout YYY Seconds ..................................5-12 VISTA-128BP/VISTA-250BP Installation and Setup Guide Index-D-4 Remote Keypad Sounder........................................3-20 REPORT CODE PROG.............................................4-3 Reporting Formats ....................................................3-5 Request to Exit (RTE) Type 12..................................4-8 Restore Report Timing ..............................................5-7 Restrict Disarming.....................................................6-1 RF Motion (RM) Type 02..................................3-16, 4-7 RF Receiver Supervision Check-in Interval..............5-10 RF System Installation Advisories............................3-14 RF System Operation and Supervision....................3-13 RF Transmitter Check-in Interval.............................5-10 RF Transmitter Low Battery Reporting.....................5-10 RF Transmitter Low Battery Sound............................5-9 Ring Detection Count .........................................5-5, 7-3 RINGER EQUIVALENCE.........................................C-1 RJ31X jack.......................................................3-5, 3-29 RLY VOICE DESCR..................................................4-3 RS-485 Bus .....................................................2-4, 3-21 RTE..........................................................................4-8 S Scheduled Check-in..................................................7-4 Scheduled Download.................................................7-4 Scheduling................................................................6-1 Scheduling Commands .............................................B-2 Scheduling Menu Mode.............................................6-4 Secondary Format ....................................................5-5 Secondary Phone Number ........................................5-4 Secondary Subscriber Account Number ....................5-7 Send Cancel If Alarm + Off......................................5-11 Send Message to Pager After Dialer........................5-14 Serial Number Devices............................................3-12 Serial Number Polling Loop (DS) Type 08..................4-8 Serial Number Polling Loop (SL) Type 06 ..................4-8 Serial Printer..................................................3-24, 3-27 SESCOA..................................................................C-1 Sescoa/Radionics.....................................................3-5 Sescoa/Radionics Select...........................................5-5 Single-Partition Single-Panel Mode............................2-4 Siren Driver...............................................................3-5 Smoke Detector Reset............................................3-20 Smoke Power Reversal Module.................................3-8 Specifications...........................................................C-1 Standard/Expanded Reporting Primary......................5-6 Standard/Expanded Reporting Secondary.................5-6 Standby Battery Size...............................................3-37 Supervised Fire (Without Verification) Type 09 ..........4-6 Supervised RF (RF) Type 03............................3-16, 4-7 Supervision Pulses for LRR.....................................5-14 Supplementary Power Supply....................................3-3 Suppress Transmitter Supervision Sound................5-11 Swinger Suppression ................................................5-7 System Commands...................................................B-1 System Communication............................................1-3 System Events Notify................................................5-1 SYSTEM LO BAT....................................................10-3 System LoBat”........................................................10-1 System Messages...................................................10-3 System Sensor A77-716B EOL Relay Module ...........3-7 System Sensor MA 12/24D.......................................3-4 System Sensor P12575 ............................................3-4 T Tamper Supervision................................................3-10 TAP protocol...........................................................3-23 Telephone Line Connections.....................................3-5 TELEPHONE OPERATIONAL PROBLEMS..............A-3 TeleSmart...............................................................3-31 Temporary Schedules......................................6-3, 6-12 Temporary Schedules Programming .......................6-13 Test Report Interval ..................................................5-3 Testing The System................................................10-1 Time Driven Events Worksheet.................................6-7 Time to Delay Pager After Dialer.............................5-14 Time Window Definitions...........................................6-2 Time Windows...................................................6-4, 6-5 Time Windows Programming ....................................6-5 Timed Events............................................................6-5 Time-Driven Events...........................................6-2, 6-7 Time-Driven Events Programming.............................6-7 TouchTone or Rotary Dial.........................................5-4 TouchTone with Rotary Backup...............................5-10 Transformer Connections........................................3-35 Transmitter Battery Life...........................................3-16 Transmitter ID Sniffer Mode....................................10-2 Transmitter Input Types..........................................3-16 Transmitter Supervision..........................................3-16 Trouble by Day/Alarm by Night Type 05 ....................4-6 Trouble Conditions..................................................10-3 Trouble Messages ..................................................10-3 Turning the System Over to the User......................10-3 U UL Installation Requirements ....................................A-1 UL1023 Household Burglary Installations ..................3-4 UL365 Police Station Connected Burglar Alarm.........A-1 UL609 Grade A Local Mercantile Premises/Local Mercantile Safe & Vault.........................................A-1 UL611/UL1610 Central Station Burglary Alarm..........A-2 UL985 Household Fire or Household Fire/Burglary Installations...........................................................3-4 UNABLE TO ARM LOBBY PARTITION.....................2-2 Unattended Download...............................................7-1 Unattended Mode .....................................................5-6 Unsupervised RF (UR) Type 04 .......................3-16, 4-7 Use Partition Descriptor..........................................5-13 User Access Codes ..................................................9-1 User Code Authority Levels.......................................9-1 User Code Commands..............................................B-1 User Code Defaults...................................................9-1 User Code Rules ......................................................9-2 User Scheduling Menu Mode ..................................6-14 Users........................................................................2-1 Using ACS Zone Inputs.............................................4-9 V VA8200 ...........................................................2-4, 3-21 VA8201...................................................................3-23 View Capabilities.......................................................9-1 VIP Module.............................................................3-28 VIP Module Phone Code...........................................5-3 VISTA Gateway Module...................................3-27, 4-9 VISTA-128B Plus as Stand-Alone Access Control...4-10 VISTA-128B PLUS Current Load.............................3-37 VistaKey..........................................................3-25, 4-9 VistaKey Dialer Enables............................................4-9 W Wheelock AS-121575W ...........................................3-4 Wire Run Length/Gauge...................................3-3, 3-21 Wireless Keypad Assignment..................................5-11 Wireless Keypad Tamper Detect.............................5-10 Wireless System Commands.....................................B-1 Wireless Zone Expansion........................................3-13 Wiring Devices to Zones 1-9......................................3-6 Wiring the Alarm Output............................................3-4 Wiring the Keypads ...................................................3-3 Worksheets to calculate the total current.................3-36 World Wide Web Address.......................................10-4 X X-10.......................................................................3-18 Y Yuasa.....................................................................3-38 Z Zone 5 Audio Alarm Verification ..............................5-12 Zone 804................................................................3-28 Zone Defaults ...........................................................4-4 Zone Index ...............................................................4-4 Zone Input Type Definitions ......................................4-7 Zone Number Designations.......................................4-4 ZONE PROG........................................................vi, 4-3 Zone Response Type Definitions...............................4-6 Zone Type Restores for Zone Types 1-8...................5-6 Zone Type Restores for Zone Types 9, 10 and 16.....5-6 Zones.......................................................................2-1 WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM While this System is an advanced wireless security system, it does not offer guaranteed protection against burglary, fire or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reasons. For example: • Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor or disconnect an alarm warning device. • Intrusion detectors (e.g., passive infrared detectors), smoke detectors, and many other sensing devices will not work without power. Battery-operated devices will not work without batteries, with dead batteries, or if the batteries are not put in properly. Devices powered solely by AC will not work if their AC power supply is cut off for any reason, however briefly. • Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm receiver. Even if the signal path has been recently checked during a weekly test, blockage can occur if a metal object is moved into the path. • A user may not be able to reach a panic or emergency button quickly enough. • While smoke detectors have played a key role in reducing residential fire deaths in the United States, they may not acti- vate or provide early warning for a variety of reasons in as many as 35% of all fires, according to data published by the Federal Emergency Management Agency. Some of the reasons smoke detectors used in conjunction with this System may not work are as follows. Smoke detectors may have been improperly installed and positioned. Smoke detectors may not sense fires that start where smoke cannot reach the detectors, such as in chimneys, in walls, or roofs, or on the other side of closed doors. Smoke detectors also may not sense a fire on another level of a residence or building. A second floor detector, for example, may not sense a first floor or basement fire. Finally, smoke detectors have sensing limitations. No smoke detector can sense every kind of fire every time. In general, detectors may not always warn about fires caused by carelessness and safety hazards like smoking in bed, violent explosions, escaping gas, improper storage of flammable materials, overloaded electrical circuits, children playing with matches, or arson. Depending on the nature of the fire and/or location of the smoke detectors, the detector, even if it operates as anticipated, may not provide sufficient warning to allow all occupants to escape in time to prevent injury or death. • Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation manual. Passive Infrared Detectors do not provide volumetric area protection. They do create multiple beams of protection, and intrusion can only be detected in unobstructed areas covered by those beams. They cannot detect motion or intrusion that takes place behind walls, ceilings, floors, closed doors, glass partitions, glass doors, or windows. Mechanical tampering, masking, painting or spraying of any material on the mirrors, windows or any part of the optical system can reduce their detection ability. Passive Infrared Detectors sense changes in temperature; however, as the ambient temperature of the protected area approaches the temperature range of 90° to 105°F (32° to 40°C), the detection performance can decrease. • Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are located on the other side of closed or partly open doors. If warning devices are located on a different level of the residence from the bed- rooms, then they are less likely to waken or alert people inside the bedrooms. Even persons who are awake may not hear the warning if the alarm is muffled by noise from a stereo, radio, air conditioner or other appliance, or by passing traffic. Finally, alarm-warning devices, however loud, may not warn hearing-impaired people. • Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service or temporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders. • Even if the system responds to the emergency as intended, however, occupants may have insufficient time to protect themselves from the emergency situation. In the case of a monitored alarm system, authorities may not respond appropriately. • This equipment, like other electrical devices, is subject to component failure. Even though this equipment is designed to last as long as 20 years, the electronic components could fail at any time. The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance. This alarm system should be tested weekly to make sure all sensors and transmitters are working properly. The security keypad (and remote keypad) should be tested as well. Wireless transmitters (used in some systems) are designed to provide long battery life under normal operating conditions. Longevity of batteries may be as much as 4 to 7 years, depending on the environment, usage, and the specific wireless device being used. External factors such as humidity, high or low temperatures, as well as large swings in temperature, may all reduce the actual battery life in a given installation. This wireless system, however, can identify a true low battery situation, thus allowing time to arrange a change of battery to maintain protection for that given point within the system. Installing an alarm system may make the owner eligible for a lower insurance rate, but an alarm system is not a substitute for insurance. Homeowners, property owners and renters should continue to act prudently in protecting themselves and continue to insure their lives and property. We continue to develop new and improved protection devices. Users of alarm systems owe it to themselves and their loved ones to learn about these developments. LIMITED WARRANTY Honeywell International Inc., acting through its Security & Custom Electronics business ("Seller") 165 Eileen Way, Syosset, New York 11791, warrants its product(s) to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the date stamp control on the product(s) or, for product(s) not having a manufacturer’s date stamp, for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period, in which case the shorter period shall apply. Seller's obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labor, any product(s) which is proved not in compliance with Seller's specifications or proves defective in materials or workmanship under normal use and service. Seller shall have no obligation under this Limited Warranty or otherwise if the product(s) is altered or improperly repaired or serviced by anyone other than Honeywell factory service. Connection of any device(s) to a communicating bus of a Honeywell security system (e.g., keypad bus, polling loop) other than those manufactured or approved by Honeywell shall void this warranty. For warranty service, return product(s) transportation prepaid, to Honeywell Factory Service, 165 Eileen Way, Syosset, New York 11791. THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE OR FAULT. Seller does not represent that the product(s) it sells may not be compromised or circumvented; that the product(s) will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the product(s) will in all cases provide adequate warning or protection. Customer understands that a properly installed and maintained alarm system may only reduce the risk of a burglary, robbery, fire, or other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THAT THE PRODUCT(S) FAILED TO GIVE WARNING. HOWEVER, IF SELLER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN, SELLER'S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT(S), WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER. VISTA-128BP/VISTA-250BP Installation and Setup Guide Index-D-2 This warranty replaces any previous warranties and is the only warranty made by Seller on this product(s). No increase or alteration, written or verbal, of the obligations of this Limited Warranty is authorized. ÊK5894V5%Š K5894V5 6/04 Rev A Before Installing This detector must be installed in compliance with the control panel installation manual and meet the requirements of NFPA 72, and/or the local authority having jurisdiction. Read this manual carefully before using the detec- tor. This manual should be left with the owner/user of this equipment. General Description The 5600 series mechanical heat detector is in- tended for use in property protection applications, or for non-life-safety installations where smoke de- tection is not practical or appropriate. WARNING For life-safety installations, smoke detectors must be used, in lieu of, or in addition to mechanical heat detectors. The 5600 series consists of both single- and dual- circuit heat detectors featuring fixed temperature thermal sensors or combination fixed temperature/ rate-of-rise sensors, with temperature ratings of 135ºF (57ºC) or 194ºF (90ºC). D500-46-00 1 I56-2175-003R INSTALLATION AND MAINTENANCE INSTRUCTIONS 3825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6495 www.systemsensor.com 5600 Series Mechanical Heat Detector Single Circuit: 5601P, 5602, 5603, 5604 Dual Circuit: 5621, 5622, 5623, 5624 Markings on the exterior of the detector indicate the specific activation method and temperature rating. All models are identified as either 135ºF/57ºC or 194ºF/90ºC. Models equipped with combination fixed tem-perature/rate-of-rise sensors are marked FX/ROR. Fixed temperature only models are marked FX. Non-Resettable Fixed Temperature Sensor The fixed temperature element reacts to heat by re- sponding to a specific temperature setting (135ºF or 194ºF). The detection method is based on the spring action of a metal contact, held to the metal chamber by a fusible alloy. When the temperature reaches the alloy’s melting point, the metal contact will depress the diaphragm, causing the electrical contact to close the circuit. The circular external heat collector is released from the detector to visu- ally indicate that the detector has been activated. NOTE: 5600 series Fixed Temperature models (5603, 5604, 5623, and 5624) are non-resettable, and can- not be tested. Specifications: Operating Voltage/Contact Ratings (Resistive): 6 – 125 VAC / 3A 6 – 28 VDC / 1A 125 VDC / 0.3A 250 VDC / 0.1A Maximum Installation Temperature: Models 5601P, 5603, 5621, and 5623: 100°F (38°C) Models 5602, 5604, 5622, and 5624: 150°F (65.6°C) Alarm Temperature: Models 5601P, 5603, 5621, and 5623: 135°F (57°C) Models 5602, 5604, 5622, and 5624: 194°F (90°C) Rate-of-Rise Threshold: 15°F (8.3°C) per minute (models 5601P, 5602, 5621, and 5622 only) Operating Humidity Range: 5 to 95% RH non-condensing Input Terminals: 14 – 22 AWG Back Box Mounting: 31⁄2˝ octagonal 4˝ octagonal Single gang 4˝ square with a square to round plaster ring Dimensions with mounting bracket: Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Weight: 6 oz. (170 grams) CAUTION To prevent the activation of the fixed temperature element, the shipping and storage temperature must not exceed 122°F (50°C). I5 6 - 2 1 7 5 - 0 0 3 R Self-Restoring Rate-of-Rise (ROR) Sensor The rate-of-rise element responds to a rapid rise of temperature, approximately 15ºF (8.3ºC) per min- ute. As the temperature rises, the air within the sealed chamber expands. Should the chamber air expand faster than it can escape through the cali- brated vent, the diaphragm is depressed, and the electrical contact closes the circuit. NOTE: Only the ROR element of 5600 series com- bination fixed temperature/ROR models (5601P, 5602, 5621, and 5622) are self-restoring, and may be tested using a hair dryer or heat gun. When testing the ROR element, to prevent the activation of the fixed temperature element, the heat source must not exceed the fixed temperature rating of the detector. Mounting Bracket All 5600 series detectors are equipped with a mount- ing bracket that includes mounting slots to accom- modate single-gang, 31⁄2˝ octagonal, and 4˝ octagonal electrical boxes, as well as 4˝ square boxes equipped with a plaster ring (Figure 1). The mounting bracket is reversible to accommodate flush-mount and sur- face–mount installations (Figure 2). Wiring Installation GuidelinesAll wiring must be installed in compliance with the National Electrical Code, applicable state and local codes, and any special requirements of the local Authority Having Jurisdiction. Proper wire gauges should be used. The conductors used to connect heat detectors to the alarm control panel and ac-cessory devices should be color-coded to reduce the D500-46-00 2 I56-2175-003R Heat Detector Type RTI Classification Fixed 135°F RTI: SPECIAL RoR and Fixed 135°F RTI: ULTRA FAST and SPECIAL (Respectively) Fixed 194°F RTI: SPECIAL RoR and Fixed 194°F RTI:ULTRA FAST and SPECIAL (Respectively) FM Classification RTI ratings are for installations which must comply with FM 3210. Table 1. 5600 Series Mechanical Heat Detectors Model No.Circuit Temperature Rating Thermal Sensor UL Maximum Spacing (10-foot ceiling) 5601P Single 135ºF (57ºC)Fixed Temperature/Rate of Rise 50-feet x 50-feet 5602 Single 194ºF (90ºC)Fixed Temperature/Rate of Rise 50-feet x 50-feet 5603 Single 135ºF (57ºC)Fixed Temperature 25-feet x 25-feet 5604 Single 194ºF (90ºC)Fixed Temperature 25-feet x 25-feet 5621 Dual 135ºF (57ºC)Fixed Temperature/Rate of Rise 50-feet x 50-feet 5622 Dual 194ºF (90ºC)Fixed Temperature/Rate of Rise 50-feet x 50-feet 5623 Dual 135ºF (57ºC)Fixed Temperature 25-feet x 25-feet 5624 Dual 194ºF (90ºC)Fixed Temperature 25-feet x 25-feet NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. A= 31⁄2˝ Octagonal boxB= 4˝ Octagonal box C= Single gang box and 4˝ square with plaster ring D= Directly to Wall/Ceiling Figure 1. Bracket Mounting Locations: S0113-00 S0114-00 S0115-00 Surface–mount Flush–mount Figure 2. Reversible Mounting Bracket: D500-46-00 3 I56-2175-003R likelihood of wiring errors. Improper connections can prevent a system from responding properly in the event of a fire. The non-polarized screw terminals on the back of the detector will accept 14–22 AWG wire. For best system performance, all wiring should be installed in separate grounded conduit; do not mix fire alarm system wiring in the same conduit as any other electrical wiring. Twisted pair may be used to pro- vide additional protection against extraneous elec- trical interference. Wire connections are made by stripping approxi- mately 1⁄4˝ of the insulation from the end of the feed wire, inserting it into the proper base terminal, and tightening the screw to secure the wire in place. + – EOL OR Control Panel Auxiliary Device Auxiliary Device Auxiliary Device Auxiliary Device Auxiliary Device Control Panel + – OR EOL Figure 3. Wiring Diagram – Single Circuit Models: Figure 4. Wiring Diagram – Dual Circuit Models: Installation Remove power from the alarm control unit or initi- ating device circuits before installing detectors. 1. Detach the detector from the mounting bracket by rotating the detector 1⁄4 turn counter-clockwise. 2. Orient the mounting bracket properly for either a flush- or surface-mount installation (Figure 2). 3. Select the pair of mounting holes suitable for the junction box, (Figure 1) and secure the bracket to the box. 4. Connect the wires to the detector per Figure 3 or Figure 4, as applicable. 5. Place the detector onto the mounting bracket by rotating clockwise. The detector will lock into place with a “click”. 6. After all detectors have been installed, apply power to the alarm control unit. 7. Test each detector as described in Testing. 8. Reset all the detectors at the alarm control unit. 9. Notify the proper authorities that the system is in operation. S0239-00 S0240-00 D500-46-00 4 I56-2175-003R ©2009 System Sensor Please refer to insert for the Limitations of Fire Alarm Systems System Sensor warrants its enclosed product to be free from defects in materials and workmanship under normal use and service for a period of three years from date of manufacture. System Sensor makes no other express warranty for the enclosed product. No agent, representative, dealer, or employee of the Company has the authority to increase or alter the obligations or limitations of this Warranty. The Company’s obligation of this Warranty shall be limited to the replacement of any part of the product which is found to be defec-tive in materials or workmanship under normal use and service during the three year period commencing with the date of manufacture. After phoning System Sensor’s toll free number 800-SENSOR2 (736-7672) for a Return Authorization number, send defective units postage prepaid to: System Sensor, Returns FCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in ac- cordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. – Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. – Consult the dealer or an experienced radio/TV technician for help. Department, RA #__________, 3825 Ohio Avenue, St. Charles, IL 60174. Please include a note describing the malfunction and suspected cause of failure. The Company shall not be obligated to replace units which are found to be defective because of damage, unrea-sonable use, modifications, or alterations occurring after the date of manufacture. In no case shall the Company be liable for any consequential or incidental damages for breach of this or any other Warranty, ex-pressed or implied whatsoever, even if the loss or dam-age is caused by the Company’s negligence or fault. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Three-Year Limited Warranty Testing/Maintenance The rate-of-rise mechanism may be subject to re- duced sensitivity over time. Annual testing of the rate-of-rise operation is therefore recommended. Before testing, notify the proper authorities that maintenance is being performed and the system will be temporarily out of service. Disable the zone or system undergoing maintenance to prevent any un- wanted alarms. Only the ROR element of 5600 series combination fixed temperature/ROR models (5601P, 5602, 5621, and 5622) are self-restoring, and may be tested us-ing a hair dryer or heat gun. WARNING When testing the ROR element, to prevent the ac- tivation of the fixed temperature element, the heat source must not exceed the fixed temperature rating of the detector. WARNING 5600 series fixed temperature models (5603, 5604, 5623, and 5624) are non-resettable, and cannot be tested. CAUTION When using the RRS-MOD with model 2WTA-B, do not mix the 2WTA-B with other model smoke de- tectors and dry contact closure devices, including mechanical heat detectors, manual pull stations and waterflow switches. Such mixing can cause a direct short on the auxiliary power terminals, damaging the control panel’s internal circuitry and/or damage devices connected to the initiating device circuit. Agency Listings Mini-Horns The SpectrAlert® Advance series of mini-horn sounders are designed to simplify installations to provide primary and secondary signaling for fire and security applications. Features • 12 and 24V operation • High and low volume settings • Temporal and non-temporal tones • Mounts to single gang back box • Compatible with MDL sync module • Mechanically and electrically compatible with PA400 series Mini-Alert™ sounders • Listing for ceiling or wall mounting The MHR and MHW mini-horns operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications, where a smaller notification device is desired. The mini-horns offer high and low volume settings, and temporal or non-temporal tones. The horns can be mounted to single gang back boxes for aesthetically sensitive applications. Synchronization is also provided when using the MDL module. The MHR and MHW mini-horns can operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supply. They are listed to Underwriter’s Laboratories Standard UL 464 for fire protective signaling systems. S4011 3028007 CS1099 7135-1653:196 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2012 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS01500 • 3/12 Ordering Information Part No.Description MHR Mini-Horn, Red MHW Mini-Horn, White SpectrAlert® Advance Mini-Horn Specifications Architectural/Engineering Specifications Mini-horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a deep single gang back box. Mini-horn shall be listed to Underwriter’s Laboratories Standard UL464 for fire protective signaling systems. Mini-horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. When used with the Sync•Circuit™ Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Physical Specifications Dimensions 4.6˝L × 2.9˝W × .45˝D Weight 2.67 oz. Operating Temperature Range 32°F to 120°F (0°C to 49°C) Mounting Surface: deep single-gang back box (23/4˝ deep) Flush: Standard 4˝ × 4˝ back box with single gang mud ring, which allows sufficient clearance for conduit entrance. Electrical Specifications Input Terminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8–33 Operating Voltage with MDL 9–33 UL Sound Output and Current Draw Data Sounder Output (dBA) Switch Setting Pattern Output Level 8–17.5 VDC 8–17.5 VFWR Nominal 12 VDC Nominal 12 VFWR 16–33 VDC 16–33 VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non- temporal High 72 71 75 74 80 79 4 Non- temporal Low 70 69 73 72 78 77 Sounder Current Draw (mA RMS) Switch Position Sound Pattern Volume 8–17.5 Volts 16–33 Volts DC FWR DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 25 4 Non-temporal Low 17 13 21 19 Agency Listings CO1224T and CO1224TR Carbon Monoxide Detectors with RealTest® Technology The System Sensor CO1224T and CO1224TR (round) Carbon Monoxide (CO) Detectors use a highly accurate and reliable electrochemical sensing cell to provide early warning of dangerous CO levels. Features • RealTest® enables a functional test using canned CO • Full compliance with UL 2075 • A code-required trouble relay • Wiring supervision with SEMS terminals • A six-year end-of-life timer • 12/24 VDC • A low current draw of 20 mA in standby and 40 mA in alarm • Versatile mounting for wall and ceiling • Accurate and reliable electrochemical sensing technology • Optional CO-PLATE CO Detector Replacement Plate to upgrade previously installed competitor detectors to the CO1224T With RealTest® technology, the CO gas sensing cell used in the CO1224T and CO1224TR CO detectors can be tested using a CO gas agent, fully meeting the requirements of NFPA 720: 2009. Simply put the detector into RealTest mode, spray a small amount of CO into the detector per the installation instructions, and within seconds the detector will alarm, indicating successful gas entry. (See the reverse page or the user manual for complete instructions.) When dangerous amounts of CO are detected, the CO1224T and CO1224TR detectors alert residents by sounding and flashing a temp 4 signal alarm. With 24/7 central station monitoring, residents are guaranteed protection whether they are away from home, sleeping, or already suffering from the effects of CO. The CO1224T and CO1224TR are designed for system operation. These detectors are fully listed to UL 2075 and offer a code- required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station. The CO1224T and CO1224TR also use SEMS-type terminal Philips head screws for quicker and more positive wiring connections and code-required wiring supervision. With a low current draw, these detectors enable more devices to be connected to the panel, limiting the need to purchase extra power supplies or more expensive panels. As 12/24 VDC detectors, the CO1224T and CO1224TR will operate on most industry security and fire alarm control panels. E307195 E304075 5276-1653:0194 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2012 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.SCDS00100 • 4/12 Ordering Information Part No.Description CO1224T 12/24 volt, 4-wire system-monitored carbon monoxide detector with RealTest® Technology CO1224TR 12/24 volt, 4-wire system-monitored round carbon monoxide detector with RealTest® Technology CO-PLATE CO detector replacement plate to cover the footprint of previously installed competitive detectors as necessary CO1224T and CO1224TR Carbon Monoxide Detector Specifications Architectural/Engineering Specifications Carbon monoxide (CO) detector shall be a system-connected System Sensor model number CO1224T or CO1224TR listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors. The detector shall be equipped with a sounder and a trouble relay. The detector’s base shall be able to mount to a single-gang electrical box or direct (surface) mount to the wall or ceiling. Wiring connections shall be made by means of SEMS screws. The detector shall provide dual-color LED indication that blinks to indicate normal standby, alarm, or end-of-life. When the sensor supervision is in a trouble condition, the detector shall send a trouble signal to the panel. When the detector gives a trouble or end-of-life signal, the detector shall be replaced. The detector shall provide a means to test CO gas entry into the CO sensing cell. The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. The detector shall perform in the detection of CO up to 12,000 feet above sea level and alarm within the time specified by ANSI/UL 2034 for CO concentrations of 70, 150 and 400 parts per million (ppm), as verified by a Nationally Recognized Test Laboratory. Electrical Specifications Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA (75 mA test) Alarm Contact Ratings 0.5 A @ 30 VDC Trouble Contact Ratings 0.5 A @ 30 VDC Physical Specifications Size: CO1224T Length: 5.1 in, Width: 3.3 in, Height: 1.3 in CO1224TR Diameter: 6 in, Height: 1.3 in Approximate Weight CO1224T: 7 oz ; CO1224TR: 11 oz Operating Temperature Range 32°F to 104° F (0°C to 40° C) Operating Humidity Range 22 to 90% RH Input Terminals 14 to 22 AWG Mounting Single-gang back box; surface mount to wall or ceiling Operation Modes Operation Mode Green LED Red LED Sounder Normal (standby)Blink 1 per minute —— Alarm —Blink in temp 4 pattern Sound in temp 4 pattern RealTest® Feature: The System Sensor CO1224T and CO1224TR Carbon Monoxide Detectors with RealTest enable evaluation of the functionality of the CO sensing cell using a canned CO test agent. Hush Feature: Pushing the Test/Hush button will silence the sounder for 5 minutes (except in RealTest mode). Trouble Feature: When the detector is in a trouble condition, it will send a trouble signal to the panel. End-of-Life Timer: After the detector’s internal sensor has reached the end of its life, a trouble signal will be sent to the panel to indicate it is time to replace the detector. An electrochemical CO detector lifespan is about six years. The detector must be replaced by the date marked on the inside of the product. CO-PLATE: System Sensor also offers the CO-PLATE CO Detector Replacement Plate to cover the footprint (when necessary) of previously installed competitive carbon monoxide detectors that require replacement. 3. Push and hold the Test/Hush button for two seconds to enter RealTest mode. The green LED will flash once every second to indicate RealTest mode has started. Spray canned CO agent into the detector. CO-PLATE Verify CO sensing at the control panel. The detector will automatically exit RealTest alarm mode after about 20-60 seconds. NOTE: Check with local codes and the AHJ to determine if a functional gas test is desired for an installation. 1.2. K5894V5 6/04 Rev A AAAAAAAADDDDDDDDEEEEEEEEMMMMMMMMCCCCCCCCOOOOOOOO VVVVVVVVIIIIIIIISSSSSSSSTTTTTTTTAAAAAAAA SSSSSSSSEEEEEEEERRRRRRRRIIIIIIIIEEEEEEEESSSSSSSS VVVVVVVVIIIIIIIISSSSSSSSTTTTTTTTAAAAAAAA--------111111112222222288888888BBBBBBBBPPPPPPPP////////VVVVVVVVIIIIIIIISSSSSSSSTTTTTTTTAAAAAAAA--------222222225555555500000000BBBBBBBBPPPPPPPP//////// VVVVVVVVIIIIIIIISSSSSSSSTTTTTTTTAAAAAAAA--------111111112222222288888888SSSSSSSSIIIIIIIIAAAAAAAA Commercial BurglaryCommercial BurglaryCommercial BurglaryCommercial Burglary Partitioned Security SystemPartitioned Security SystemPartitioned Security SystemPartitioned Security System With SchedulingWith SchedulingWith SchedulingWith Scheduling Installation and Setup Guide . iii Table of Contents •••••••••••••••••••••••••••••••••••••••••••••••• •• List of Figures...................................................................................................................................................vi Conventions Used in This Manual..................................................................................................................vii SECTION 1: General Description...................................................................................................................1-1 About the VISTA-128BP/VISTA-250BP.......................................................................................................................1-1 Features....................................................................................................................................................................1-2 SECTION 2: Partitioning and Panel Linking..................................................................................................2-1 Theory of Partitioning .................................................................................................................................................2-1 Setting-Up a Partitioned System.................................................................................................................................2-1 Common Lobby Logic.................................................................................................................................................2-1 Master Keypad Setup and Operation..........................................................................................................................2-3 Panel Linking..............................................................................................................................................................2-4 SECTION 3: Installing the Control.................................................................................................................3-1 Mounting the Control Cabinet .....................................................................................................................................3-1 Installing the Cabinet Lock..........................................................................................................................................3-1 Grade A Mercantile Premises Listing Guidelines.........................................................................................................3-1 Grade A Mercantile Safe and Vault Listing Guidelines.................................................................................................3-2 Installing the Control's Circuit Board...........................................................................................................................3-2 Installing the Keypads ................................................................................................................................................3-4 Installing External Sounders.......................................................................................................................................3-4 Telephone Line Connections ......................................................................................................................................3-5 Wiring Burglary, Panic and Smoke Detector Devices to Zones 1-9..............................................................................3-5 Installing RPM Devices.............................................................................................................................................3-11 Wireless Zone Expansion .........................................................................................................................................3-13 Installing Output Devices..........................................................................................................................................3-17 Installing the Ground Start Module............................................................................................................................3-18 Installing a Remote Keyswitch..................................................................................................................................3-16 Smoke Detector Reset.............................................................................................................................................3-20 Remote Keypad Sounder .........................................................................................................................................3-20 Installing the VA8200 Panel Link Module ..................................................................................................................3-20 Long Range Radio Connected to the J7 Triggers......................................................................................................3-22 Long Range Radio Connected to the ECP ................................................................................................................3-22 Installing the Alpha Pager Module.............................................................................................................................3-23 Access Control Using VistaKey.................................................................................................................................3-25 Access Control Using the PassPoint Access Control System....................................................................................3-26 Installing a 4100SM..................................................................................................................................................3-27 Installing the 4285/4286 VIP Module.........................................................................................................................3-28 Installing the Audio Alarm Verification Module...........................................................................................................3-30 Installing TeleSmart..................................................................................................................................................3-31 Connecting the Transformer.....................................................................................................................................3-35 Panel Earth Ground Connections .............................................................................................................................3-36 Determining the Control’s Power Supply Load ..........................................................................................................3-36 Determining the Size of the Standby Battery.............................................................................................................3-37 SECTION 4: Programming..............................................................................................................................4-1 Program Modes .........................................................................................................................................................4-1 Entering and Exiting Programming Mode....................................................................................................................4-1 Data Field Programming Mode...................................................................................................................................4-1 #93 Menu Mode Programming ...................................................................................................................................4-2 Zone Number Designations ........................................................................................................................................4-4 Zone Response Type Definitions ................................................................................................................................4-6 Zone Input Type Definitions........................................................................................................................................4-7 Programming for Panel Linking...................................................................................................................................4-8 Programming for the Alpha Pager Module ..................................................................................................................4-8 Programming for 4100SM ..........................................................................................................................................4-9 Table of Contents iv Programming for Access Control................................................................................................................................4-9 Programming for ECP Long Range Radio.................................................................................................................4-10 Programming for TeleSmart.....................................................................................................................................4-10 SECTION 5: Data Field Descriptions .............................................................................................................5-1 About Data Field Programming...................................................................................................................................5-1 Programming Data Fields...........................................................................................................................................5-1 SECTION 6: Scheduling Options...................................................................................................................6-1 Time Window Definitions ............................................................................................................................................6-2 Open/Close Schedules Definitions..............................................................................................................................6-2 Scheduling Menu Mode..............................................................................................................................................6-4 Time Windows............................................................................................................................................................6-5 Daily Open/Close Schedules ......................................................................................................................................6-2 Holiday Schedules......................................................................................................................................................6-1 Time-Driven Events....................................................................................................................................................6-1 Limitation of Access Schedules ..................................................................................................................................6-1 Temporary Schedules ..............................................................................................................................................6-12 User Scheduling Menu Mode....................................................................................................................................6-14 SECTION 7: Downloading Primer..................................................................................................................7-1 General Information ...................................................................................................................................................7-1 Unattended Download ................................................................................................................................................7-1 Getting On-Line with a Control Panel..........................................................................................................................7-3 Scheduled Download................................................................................................................................................7-16 Direct-Wire Downloading..........................................................................................................................................7-16 Telco Handoff.............................................................................................................................................................7-2 SECTION 8: Setting the Real-Time Clock......................................................................................................8-1 General Information ...................................................................................................................................................8-1 Setting the Time and Date..........................................................................................................................................8-1 SECTION 9: User Access Codes ....................................................................................................................9-1 General Information ...................................................................................................................................................9-1 User Codes & Levels of Authority ...............................................................................................................................9-1 Multiple Partition Access.............................................................................................................................................9-2 Adding a Master, Manager, or Operator Code ............................................................................................................9-2 Changing a Master, Manager, or Operator Code ........................................................................................................9-4 Adding an RF Key to an Existing User........................................................................................................................9-4 Deleting a Master, Manager, or Operator Code ..........................................................................................................9-4 Exiting the User Edit Mode.........................................................................................................................................9-5 SECTION 10: Testing the System................................................................................................................10-1 Battery Test.............................................................................................................................................................10-1 Dialer Test...............................................................................................................................................................10-1 Burglary Walk-Test (Code + [5] TEST)......................................................................................................................10-1 Armed Burglary System Test....................................................................................................................................10-1 Testing Wireless Transmitters..................................................................................................................................10-2 Trouble Conditions...................................................................................................................................................10-2 To the Installer.........................................................................................................................................................10-2 APPENDIX A: Regulatory Agency Statements.............................................................................................A-1 UL Installation Requirements......................................................................................................................................A-1 UL609 Grade A Local Mercantile Premises/Local Mercantile Safe & Vault ..................................................................A-1 UL365 Police Station Connected Burglar Alarm ..........................................................................................................A-1 UL611/UL1610 Central Station Burglary Alarm ...........................................................................................................A-2 California State Fire Marshal (CSFM) and UL Residential Fire Battery Backup Requirements .....................................A-2 APPENDIX B: Summary of System Commands...........................................................................................B-1 APPENDIX C: Specifications.........................................................................................................................C-1 APPENDIX D: Contact ID and Pager Event Codes.......................................................................................D-1 TABLE OF CONTACT ID EVENT CODES..................................................................................................................D-1 Event Log and Pager Alpha Descriptors .....................................................................................................................D-1 Index.........................................................................................................................................................Index-1 THE LIMITATIONS OF THIS ALARM SYSTEM Table of Contents v ADEMCO LIMITED WARRANTY vi List of Figures •••••••••••••••••••••••••••••••••••••••••••••••• •• Figure 3-1: Installing the Lock...........................................................................................................................................3-1 Figure 3-2: Cabinet Attack Resistance Considerations......................................................................................................3-2 Figure 3-3: Mounting the PC Board ..................................................................................................................................3-4 Figure 3-4: Keypad Connections to Control Panel.............................................................................................................3-4 Figure 3-5: Using A Supplementary Power Supply............................................................................................................3-4 Figure 3-6: Wiring Polarized Fire Devices.........................................................................................................................3-5 Figure 3-7: Wiring Nonpolarized Burglary Devices ............................................................................................................3-5 Figure 3-8: Telephone Line Connections ..........................................................................................................................3-5 Figure 3-9: Wiring Connections for Zones 1-9...................................................................................................................3-6 Figure 3-10: 2-Wire Smoke Detector on Zone 1................................................................................................................3-8 Figure 3-11: 4-Wire Smoke Detectors...............................................................................................................................3-8 Figure 3-12a: Wiring a 333PRM to the Control..................................................................................................................3-2 Figure 3-12b: Wiring a 333PRM using a 4204...................................................................................................................3-2 Figure 3-12c: Wiring a 333PRM using a 4204 and a Power Supply ...................................................................................3-9 Figure 3-13: Wiring Latching Glassbreaks to Zone 8..........................................................................................................3-9 Figure 3-14: Wiring a Normally Closed Loop for Tamper Supervision..............................................................................3-11 Figure 3-15: Wiring a Normally Open Loop for Tamper Supervision................................................................................3-11 Figure 3-16: Polling Loop Connections to the VISTA-128BP/VISTA-250BP.....................................................................3-13 Figure 3-17: Polling Loop Connections Using One 4297 Extender Module ......................................................................3-13 Figure 3-18: Polling Loop Connections Using Multiple Extender Modules........................................................................3-13 Figure 3-19: Installing the 5881ENHC with Tamper Protection .........................................................................................3-14 Figure 3-20: 5881 RF Receiver (cover removed)............................................................................................................3-15 Figure 3-21: 4204 Relay Module.....................................................................................................................................3-17 Figure 3-22: 4204CF Relay Module ................................................................................................................................3-17 Figure 3-23: Wiring the FSA Module...............................................................................................................................3-18 Figure 3-24: Ground Start Module Connections..............................................................................................................3-16 Figure 3-25: Remote Keyswitch Wiring...........................................................................................................................3-20 Figure 3-26: Remote Keypad Sounder Wiring.................................................................................................................3-20 Figure 3-27: Panel Linking Block Diagram ......................................................................................................................3-20 Figure 3-28: VA8200 Panel Link Module Wiring..............................................................................................................3-20 Figure 3-29: Wiring Long Range Radio to Keypad Terminals ..........................................................................................3-23 Figure 3-30: Wiring the Alpha Pager Module...................................................................................................................3-25 Figure 3-31: Wiring the VistaKey.....................................................................................................................................3-26 Figure 3-32: Wiring the VISTA Gateway Module.............................................................................................................3-27 Figure 3-33: 4100SM Using a Serial Printer.....................................................................................................................3-27 Figure 3-34: 4100SM Using Home Automation ...............................................................................................................3-28 Figure 3-35: VIP Module Connections ............................................................................................................................3-29 Figure 3-36: UVS Connections to the Control Panel........................................................................................................3-31 Figure 3-37: TeleSmart Phone Connections ...................................................................................................................3-33 Figure 3-38: TeleSmart Speaker Connection ...................................................................................................................3-33 Figure 3-39: Keypad Connections....................................................................................................................................3-34 Figure 3-40: RTC and Ground Connections.....................................................................................................................3-34 Figure 3-41: TeleSmart to Control Connections ...............................................................................................................3-34 Figure 3-42: 1361 Transformer and Battery Connections................................................................................................3-35 Figure 3-43: 1361X10 Transformer Connections.............................................................................................................3-35 Figure 7-1: Direct-Wire Downloading Connections ............................................................................................................7-2 vii Conventions Used in This Manual •••••••••••••••••••••••••••••••••••••••••••••••• •• Before you begin using this manual, it is important that you understand the meaning of the following symbols (icons). UL These notes include specific information that must be followed if you are installing this system for a UL Listed application. These notes include information that you should be aware of before continuing with the installation, and that, if not observed, could result in operational difficulties. This symbol indicates a critical note that could seriously affect the operation of the system, or could cause damage to the system. Please read each warning carefully. This symbol also denotes warnings about physical harm to the user. ZONE PROG? 1 = YES 0 = NO 0 Many system options are programmed in an interactive mode by responding to alpha keypad display prompts. These prompts are shown in a single-line box. ✴00 Additional system options are programmed via data fields, which are indicated by a “star” (✴) followed by the data field number. PRODUCT MODEL NUMBERS: Unless noted otherwise, references to specific model numbers represent ADEMCO products. 1-1 SECTION 1 General Description •••••••••••••••••••••••••••••••••••••••••••••••• •• About the VISTA-128BP/VISTA-250BP All references to the VISTA-128BP also pertain to the VISTA-128SIA. The differences between the two panels are outlined in the supplement accompanying the VISTA-128SIA. The supplement must be referred to when programming the VISTA-128SIA. The VISTA-128BP/VISTA-250BP is an 8-partition, UL Listed control panel with the following features: • Supports hardwired, polling loop, and wireless zones • Supervision of bells, keypads, RF receivers, and output devices • Scheduling capabilities (allows certain operations to be automated) • The capability to link up to 8 control panels using Panel Linking Modules The VISTA-128BP/VISTA-250BP can interface with the following devices: • TeleSmart (See the TeleSmart instructions for operating procedures) • An alpha numeric paging device (VA8201) • Symphony (AUI) • Panel Link Module (VA8200) • Voice Keypad (6160V) • An ECP Long Range Radio that can send Contact ID messages • An access control system by using either the ADEMCO PassPoint system (via the VISTA Gateway Module) or a VistaKey module (via the polling loop) UL The access control function is not Listed for use with the VISTA-128BP/VISTA-250BP Control Panel in a UL installation. The system supports either the VistaKey or the VISTA Gateway Module, not both. NOTE: All references in this manual for number of zones, number of user codes, number of access cards, and the event log capacity, use the VISTA-250BP’s features. The following table lists the differences between the VISTA-128BP and the VISTA-250BP control panels. All other features are identical, except for the Remote Keypad Sounder (field 1✴46 option 2), which is available only in the VISTA128BP. Feature VISTA-128BP VISTA-250BP Number of Zones 128 250 Number of User Codes 150 250 Number of Access Cards 250 500 Event Log Capacity 512 1000 VistaKey Modules 8 15 VISTA-128BP/VISTA-250BP Installation and Setup Guide 1-2 Features Hardwire and Optional Expansion Zones • Provides 9 hardwire zones. • Supports up to 16 2-wire smoke detectors on zone 1. • Automatically resets 4-wire smoke detectors using the J7 output when a code + off is entered. • Triggers the built-in sounders on other hardwired smoke detectors if one smoke detector annunciates an alarm. This feature requires a 4204 Relay Module and/or the 333PRM. • Provides tamper supervision on the hardwire zones. • Supports up to 50 2-wire latching glassbreak detectors on zone 8. • Supports up to 241 additional expansion zones (119 for the VISTA-128BP) using a built-in polling (multiplex) loop. • Supports up to 250 wireless zones (128 for the VISTA-128BP) (fewer if using hardwire and/or polling loop zones). UL The 5881ENHC RF Receiver and the 5869 Holdup Switch Transmitter are listed for UL Commercial Burglary applications. All other RF receivers and transmitters are not listed for UL Commercial Burglary applications. • Can program burglary zones as silent in the alarm condition (alarm output is silent and the keypad does not display or sound the alarm). • Provides three keypad panic keys: 1 + ✴ (A), ✴ + # (B), and 3 + # (C). Peripherals Devices • Supports up to 31 addressable devices, (keypads, RF receivers, relay modules, etc.). • Supervises devices (keypads, RF receivers, and relay modules) and individual relays (up to 32), as well as system zones (RF receivers and keypad panics). • Provides 96 outputs using 4204 and 4204CF Relay Modules, Fire System Annunciators (FSA-8, FSA-24), V-Plex Relay Modules and X-10 devices can activate outputs in response to system events (alarm condition), at a specific time of day, at random times, and manually using the #70 Relay Command Mode. • Supports the ADEMCO 4285/4286 VIP Module, which allows access to the system from either a remote location or on the premises UL The VIP Module is not Listed for use with the VISTA-128BP/VISTA-250BP Control Panel in a UL installation. • Supports the ADEMCO 4146 Keyswitch on any one of the system's 8 partitions. Arming/Disarming and Bypassing • Can arm the system with zones faulted (Vent Zone). These zones are automatically bypassed and can be programmed to automatically unbypass when the zone restores. • Can arm with entry/exit and interior type zones faulted (Arm w/Fault). These zones must be restored before the exit delay expires, otherwise an alarm is generated. UL • Vent zones cannot be used in UL installations. • You must disable the Force Arm option (used in conjunction with the Arm w/Fault option), in UL installations. • Provides global arming capability (ability to arm all partitions the user code has access to in one command). • Can Quick Exit an armed premises without having to disarm and then rearm the system. UL Quick Exit is not permitted for use with the VISTA-128BP/VISTA-250BP Control Panel in a UL installation. Section 1 - General Description 1-3 • Can be armed in one of three STAY modes or Instant modes, automatically bypassing specific burglary zones regardless of the zone response type. • Can automatically bypass specific zones if no one exits the premises after arming (Auto-STAY). Auto-STAY will not occur if the system is armed via an RF transmitter, VIP module, scheduling, access control, keyswitch, RS232 automation or downloading. • Can bypass a group of zones with one set of keystrokes. • Supports Exit Error Logic, whereby the system can tell the difference between a regular alarm and an alarm caused by leaving an entry/exit door open. If the system is not subsequently disarmed, faulted E/E zone(s) and/or interior zones are bypassed and the system arms. • Supports Recent Close report, which is designed to notify the central station that an alarm has occurred within 2 minutes after the exit delay has expired. Partitioning and Panel Linking • Can control 8 separate areas independently, each functioning as if it had its own separate control. • Provides a Common Lobby partition, which can be programmed to arm automatically when the last partition is armed, and to disarm when the first partition is disarmed. • Provides a Master partition (9), used for the purpose of viewing the status of all partitions at the same time. • Can display fire, burglary, panic and trouble conditions at all other partitions’ keypads (selectable option). • Can “link” together up to 8 control panels. This allows users to access and control from a keypad another control panel. Scheduling • Can automate system functions, such as arming, disarming, and activation of outputs (e.g., lights). • Provides access schedules (for limiting system access to users by time). • Provides an End User Output Programming Mode, allowing the user to control outputs. Access Control • Supports up to 15 VistaKey modules (15 access points) (VISTA-128BP supports 8 modules), which are used for access control. It is a single-door access control module. • Support up to 500 access cards. • Supports ADEMCO PassPoint system via one VISTA Gateway Module (VGM), for a fully integrated access control system. • Can store access control events in the event log. System Communication • Supports ADEMCO Contact ID; ADEMCO High Speed; ADEMCO Express; and 3+1, 4+1, and 4+2 ADEMCO and Sescoa/Radionics Low-Speed formats. The system is shipped defaulted for Contact ID communication. It is the only format capable of uniquely reporting all 250 zones, as well as openings and closings for all 250 users. This requires central stations to be equipped with the ADEMCO 685 receiver using software level 4.10 or higher to fully support all new VISTA-128BP/VISTA-250BP report codes. If you need to update your 685 receiver, contact your distributor. • Can send messages such as alarms, opens/closes, etc. to up to 8 paging services. • Provides two paging formats (alphanumeric – requires the VA8201 Alpha Pager Module; and numeric – sent directly by the control) • Supports Dynamic Signaling feature, which prevents redundant signals being sent to the central station when both the built-in dialer and Long Range Radio are used. • Provides an Audio Alarm Verification (AAV) option that permits voice dialog between an operator at the central station and a person at the premises. An AAV unit, such as ADEMCO UVS, is required. VISTA-128BP/VISTA-250BP Installation and Setup Guide 1-4 Downloading • Supports upload and download capability. • Can perform unattended downloading (no one at the downloading computer). • Provides an Installer Unattended Program Mode. This allows the installer to program the download phone number, subscriber number, and primary central station receiver phone number without entering the normal program mode. • Can periodically and automatically perform a scheduled download. UL Unattended and Scheduled Downloading are not UL Listed features. • Can download access control cardholder information. Event Log • Provides an event log (history log) that can store up to 1000 events. • Can print the event log on a parallel or serial printer using a VA8201 Alpha Pager Module. • Can view the event log on an alpha keypad or AUI. Additional Features • Provides up to 60 installer-defined, custom words that can be used for zone descriptors. • Provides 32 keypad macro commands (each macro is a series of keypad commands of up to 32 keystrokes) using the A, B, C, and D keys by partition. • Provides cross-zone capability, which helps prevent false alarms by preventing a zone from going into alarm unless its cross-zone is also faulted within a 5-minute period. • Contains a built-in User’s Manual, which provides the end user with a brief explanation of the function of a key when the user presses any of the function keys on the keypad for 5 seconds. • Provides trigger outputs, which may interface with Long Range Radio equipment or other devices such as keyswitch LEDs, printer, or pager. • Provides an RS232 input for serial data. This is useful for interfacing the system with Automation software. Automation software cannot be used if a serial printer is used on the system. At least one 2-line alpha keypad (6139/6160) must be connected to the system for programming (if you are using keypad programming), and must remain connected to the system in order to allow the primary user to program additional user codes into the system at a later time. 2-1 SECTION 2 Partitioning and Panel Linking •••••••••••••••••••••••••••••••••••••••••••••••• •• Theory of Partitioning This system provides the ability to arm and disarm up to 8 different areas, as if each had its own control. These areas are called partitions. A Partitioned system allows the user to disarm certain areas while leaving other areas armed, or to limit access to certain areas to specific individuals. Each system user can be assigned to operate any or all partitions, and can be given a different authority level in each. Before anything can be assigned to those partitions, you must first determine how many partitions (1-8) are required. Following are some facts you need to know about partitioning. Keypads Each keypad must be given a unique "address" and be assigned to one partition. It can also be assigned to Partition 9 if Master keypad operation is desired. (See “Master Keypad Setup and Operation” later in this section.) Zones Each zone must be assigned to one partition. The zones assigned to a partition will be displayed on that partition's keypad(s). Users Each user may be given access to one or more partitions. If a user is to operate more than one partition and would like to arm/disarm all or some of those partitions with a single command, the user must be enabled for Global Arming for those partitions (when entering user codes). A user with access to more than one partition (multiple access) can "log on" to one partition from another partition's keypad, provided that program field 2*18: Enable GOTO is enabled for each partition he/she wants to log on to from another. A partition can be selected as a "common lobby" partition, and other partitions can affect this partition by causing arming/disarming of this partition to be automated (see “Common Lobby Logic” later in this section). Setting-Up a Partitioned System The basic steps to setting up a partitioned system are described below. If you need more information on how to program the options, see SECTION 4: Programming. 1. Determine how many partitions the system will consist of (programmed in field 2*00). 2. Assign keypads to partitions (Device Programming in the #93 Menu Mode). 3. Assign zones to partitions (Zone Programming in the #93 Menu Mode). 4. Confirm zones are displayed at the keypad(s) assigned to those partitions. 5. Assign users to partitions. 6. Enable the GOTO feature (program field 2*18) for each partition a multiple-access user can log on to (alpha keypad only). 7. Program partition-specific fields (see the Data Field Descriptions section). Common Lobby Logic When an installation consists of a partition shared by users of other partitions in a building, that shared partition may be assigned as the "common lobby" partition for the system (program field 1*17). An example of this might be in a medical building where there are two doctors’ offices and a common entrance area (see example that follows explanation). The Common Lobby feature employs logic for automatic arming and disarming of the common lobby. Two programming fields determine the way the common lobby will react relative to the status of other partitions. They are: 1*18 Affects Lobby and 1*19 Arms Lobby. VISTA-128BP/VISTA-250BP Installation and Setup Guide 2-2 1*18 Affects Lobby (must be programmed by partition) Setting this field to 1 for a specific partition causes that partition to affect the operation of the common lobby as follows: a. When the first partition that affects the lobby is disarmed, the lobby is automatically disarmed. b. The common lobby cannot be armed unless every partition selected to affect the lobby is armed. 1*19 Arms Lobby (must be programmed by partition) Setting this field to 1 for a specific partition causes that partition to affect the operation of the common lobby as follows: a. The common lobby cannot be armed unless every partition selected to affect the lobby is armed. b. Arming a partition that is programmed to arm the lobby causes the system to automatically attempt to arm the lobby. If any faults exist in the lobby partition, or if another partition that affects the lobby is disarmed, the lobby cannot be armed, and the message "UNABLE TO ARM LOBBY PARTITION" is displayed. You cannot select a partition to "arm" the lobby unless it has first been selected to "affect" the lobby. Do not enable field 1*19 without enabling field 1*18. The following chart sums up how the common lobby partition will operate. 1*18 Affects Lobby 1*19 Arms Lobby Disarms when partition disarms? Attempts to arm when partition arms? Can be armed if other partitions disarmed? 0 0 NO NO YES 1 0 YES NO NO 1 1 YES YES NO 0 1 ---ENTRY NOT ALLOWED--- Example Here is an example of how the lobby would react in a typical setup. OFFICE 1OFFICE 2 MAIN ENTRANCE COMMON LOBBY V128BP-001-V0 User #1 has access to Office #1 and the Common Lobby. User #2 has access to Office #2 and the Common Lobby. Office #1 is set up to affect the Common Lobby, but not arm it. Office #2 is set up to affect and arm the Common Lobby. NOTE: In the tables below, the notations in parentheses ( ) indicate the current status of the other partition when the user takes action. Sequence #1: Office 1 Office 2 Lobby Action User #1: Disarms (Armed) Disarms User #2: (Disarmed) Disarms No Change User #1: Arms (Disarmed) No change User #2: (Armed) Arms Arms Sequence #2: Office 1 Office 2 Lobby Action User #2: (Armed) Disarms Disarms User #1: Disarms (Disarmed) (No change) User #2: (Disarmed) Arms No Change User #1: Arms (Armed) No Change Notice that in sequence #1, because Office #2 was the last to arm, the lobby also armed (Office #2 is programmed to affect and arm the lobby). In sequence #2, the lobby could not arm when Office #2 armed, because Office #1, which affects the lobby, was still disarmed. When Office #1 armed, the lobby still did not arm because Office #1 was not programmed to arm the lobby. User #1 would have to arm the lobby manually. Therefore, you would want to program a partition to Section 3 - Installing the Control 2-3 affect and arm the lobby if the users of that partition are expected to be the last to leave the building. How User Access Codes Affect the Common Lobby Codes with Global Arming If a code is given "global arming" when it is defined (see SECTION 9: User Access Codes), the keypad prompts the user to select the partitions they want to arm. Only the partitions the user has access to are displayed. This allows the user to choose the partitions to be armed or disarmed, and so eliminates the "automatic" operation of the lobby. Keep in mind, however, that if a user attempts to arm all, and another "affecting" partition is disarmed, the user cannot arm the lobby, and the message "UNABLE TO ARM LOBBY PARTITION" is displayed. Codes with Non-Global Arming If a user arms with a non-global code, the lobby partition operation is automatic, as described by fields 1*18 and 1*19. Other Methods of Arming/Disarming Common Lobby logic remains active when arming or disarming a partition that affects and/or arms the common lobby in one of the following manners: • Quick-Arm • Keyswitch • Wireless Button • Wireless Keypad Arming/Disarming Remotely If a user arms or disarms remotely (through Compass downloading software), the lobby does not automatically follow another partition that is programmed to arm or disarm the lobby. The lobby must be armed separately, after arming all affecting partitions first. Auto-Arming/Disarming If scheduling is used to automatically arm and/or disarm partitions, the common lobby partition does not automatically follow another partition that is programmed to arm or disarm the lobby. The lobby must be included as a partition to be armed/disarmed and must be scheduled as the last partition armed. If you are using auto-arming, make sure that the Auto-Arm Delay and Auto-Arm Warning periods, for the lobby partition, (fields 2*05 and 2*06) combined are longer than that of any other partition that affects the lobby. This causes the lobby to arm last. Master Keypad Setup and Operation Although this system has eight actual partitions, it provides an extra partition strictly for the purpose of assigning keypads as Master keypads for the system. Assigning any keypad to Partition 9 in Device Programming in the #93 Menu Mode makes that keypad a Master keypad. A Master keypad reflects the status of the entire system (Partitions 1-8) on its display at one time. This is useful because it eliminates the need for a building security officer to have to log on to various partitions from one partition's keypad to find out where an alarm has occurred. The following is a typical display: S Y S T E M 1 2 3 4 5 6 7 8 S T A T U S R R N N A ✴ B Possible status indications include: A = Armed Away S = Armed Stay M = Armed Maximum C = Comm Fail I = Armed Instant R = Ready N = Not Ready B = Bypassed/Ready ✴ = Alarm T = Trouble F = Fire Alarm P = AC Power Failure L = Low System Battery To obtain more information regarding a particular partition, enter [✴] + Partition No. (e.g., [✴] + [4]). This allows viewing only of that partition. In order to affect that partition, the user must use a code that has access to that partition. Also, in order for a user of any partition to log on to Partition 9 to view the status of all partitions, that user must have access to all partitions. Otherwise, access is denied. The following is displayed for a fault condition on Zone 2 (Loading Dock Window) on Partition 1 (Warehouse) when a user logs on from a keypad on Partition 9: WHSE DISARMED HIT ✴ FOR FAULTS Pressing [✴] causes the following display to appear at Partition 1's keypad(s): FAULT 002 LOADING DOCK WINDOW Additional zone faults are displayed one at a time. To display a new partition's status, press [✴] + Partition No. The Armed LED on a Master keypad is lit only if all partitions have been armed successfully. The Ready LED is lit only if all partitions are "ready to arm." Neither LED is lit if only some partitions are armed and/or only some partitions are ready. VISTA-128BP/VISTA-250BP Installation and Setup Guide 2-4 Press [✴] + [0] or [✴] + [9] to return to the master partition. Otherwise, if no keys are pressed for 2 minutes, the system automatically returns to the master partition The sounder on a Master keypad reflects the sound of the most critical condition on all of the partitions. The priority of the sounds, from most to least critical, is as follows: 1. Pulsing fire alarm sounds 2. Steady burglar alarm sounds 3. Trouble sounds (rapid beeping) Silence the sounder by pressing any key on the Master keypad or a keypad on the partition where the condition exists. A Master keypad uses the same panics as Partition 1. Master keypad panics are sent to Partition 1, and will activate on Partition 1. Therefore, panics must be programmed for Partition 1. Panel Linking Up to eight VISTA-128BP/VISTA-250BP control panels may be networked, enabling a user to control the features of all control panels from a single location. The panel linking bus supports an end-to-end network length of up to 4,000 feet. This makes it ideal for multi-building environments (e.g., shopping mall, college campus, etc.). UL Panel Linking is not permitted in UL installations. Panel linking requires a VA8200 Panel Link Module (PLM) on each VISTA-128BP/VISTA-250BP. Users can link (access other control panels) in any of three different modes: Single-Partition, Single-Panel Mode; Multi-Partition, Multi-Panel Mode; Multi-Panel View Mode. These modes are described later in this section. Each PLM connects to the ECP bus on the control panel and communicates to each PLM via an RS-485 bus (3-wire twisted cable run) with a maximum wire- run of 4000 feet end-to-end. • Users 001-050 are the only users that can perform panel linking and are automatically assigned panel linking access when added to the system. • An alpha keypad must be used for panel linking. • The system may take up to 7 seconds to respond to a command when in a panel linking mode NOTE: A user cannot access partitions or panels that they have not been assigned to. Panel Link Module Supervision The Panel Link Module can be supervised for its connection to the control panel. The module’s supervisory zone is zone 8xx, where “xx” = the ECP address of the PLM. You must program that zone with response type 05 (Day/Night) in Zone Programming in the #93 Menu Mode (refer to the Programming Guide for detailed programming instructions). If you want to report the supervisory failure to the central station and/or to a paging service, the appropriate reporting parameters for that zone must be programmed. If you want the supervisory failure of PLM(s) on other linked control panels to display on this control panel, they must be programmed into Zone Programming in the #93 Menu Mode with response type 14 in this control panel (refer to the Programming Guide for detailed programming instructions). The panel ID number for each module must match the panel ID number programmed in Device Programming of its “host” VISTA-128BP/VISTA-250BP. How to Use Panel Linking Panel Linking can be used in any of three different modes: • Single-Partition, Single-Panel − displays status of a partition on a remote control panel and allows control of that remote control panel. • Multi-Partition, Multi-Panel Mode − displays status and allows arming/disarming of multiple partitions at once on a remote control panel. • Multi-Panel View Mode − displays status and allows arming/disarming of multiple remote control panels at a time. NOTE: A user will not be able to access or view partitions or panels that they have not been assigned to. VISTA-128BP/VISTA-250BP Installation and Setup Guide 2-4 Single-Partition Single-Panel Mode To access the Single-Partition, Single Panel mode, perform the following steps: Step Action 1 Enter User Code (for users 001-050) + [#] + [86]. 2 Enter the panel ID number (01-08) of the panel you want to link to. 3 Enter the partition number of the panel. The keypad displays “AWAITING PANEL LINK.” After a few seconds, the keypad displays the status of the partition along with the panel ID number and partition number flashing in the upper right-hand corner. The user now has full control of the remote control panel. All functions can be performed except the following: • Those limited by the user’s authority level. • The user cannot enter Installer Program mode. • The user cannot execute another panel linking mode. NOTE: To execute another panel linking mode or to access a different remote panel, the user must first exit this mode (return to the original control panel). 4 To exit, enter the User Code (for users 001-050) + [#] + [85]. After a few seconds, the keypad displays the status of the original partition for the keypad. Multi-Partition Multi-Panel Mode To perform a function in the Multi-Partition, Multi Panel mode, follow the steps below: Step Action 1 Enter User Code (for users 001-050) + [#] + [88]. The keypad displays the following: PANELnn 1 2 3 4 5 6 7 8 STATUS x x x x x x x x where “nn” = panel ID number (01-08), “12345678” are the partition numbers and “xxxxxxxx” is the status of each partition of that panel. Status indications include: A = Armed Away S = Armed Stay M = Armed Maximum I = Armed Instant R = Ready N = Not Ready B = Bypassed/Ready ✴ = Alarm T = Trouble F = Fire Alarm P = AC Power Failure L = Low System Battery C = Comm Fail NOTES: See table later in this section for priority of displays. A “•” under a partition number indicates the user does NOT have access to that partition. 2 The following functions can be performed: Press [1] to attempt to disarm all partitions. Press [2] to attempt to arm AWAY all partitions. Press [3] to attempt to arm STAY all partitions. Press [4] to attempt to arm MAXIMUM all partitions. Press [7] to attempt to arm INSTANT all partitions. Press [✴] to read the status of the next panel. Press [#] key to read the status of the previous panel. Press [0] to exit mode. After a few seconds, the keypad displays the status of the original partition of the original panel for the keypad. Also, this mode will end in approximately 120 seconds if no keys are pressed. NOTES: When performing any of the arming commands, if there are faults in any of the partitions, none of the partitions will arm. These faults must be corrected or bypassed before attempting to arm. When performing either a STAY or INSTANT arm command the system always arms in mode VISTA-128BP/VISTA-250BP Installation and Setup Guide 2-6 1. The user cannot execute another panel linking mode. To execute another panel linking mode or to access a different remote panel, the user must first exit this mode (return to the original control panel). Multi-Panel View Mode To perform a function in the Multi-Panel View mode, follow the steps below: Step Action 1 Enter User Code (for users 001-050) + [#] + [87]. The keypad displays the following typical display: ALLPANEL 1 2 3 4 5 6 7 8 STATUS x x x x x x x x where “12345678” are the panel ID numbers and “xxxxxxxx” is the overall status of each panel. Status indications include: A = Armed Away S = Armed Stay M = Armed Maximum I = Armed Instant R = Ready N = Not Ready B = Bypassed/Ready ✴ = Alarm T = Trouble F = Fire Alarm P = AC Power Failure L = Low System Battery C = Comm Fail NOTE: See table later in this section for priority of displays. 2 The following functions can be performed:: Press [1] to attempt to disarm all partitions on all panels. Press [2] to attempt to arm AWAY all partitions on all panels. Press [3] to attempt to arm STAY all partitions on all panels. Press [4] to attempt to arm MAXIMUM all partitions. Press [7] to attempt to arm INSTANT all partitions. Press [0] to exit mode. After a few seconds, the keypad displays the status of the original partition of the original panel for the keypad. Also, this mode will end in approximately 120 seconds if no keys are pressed. NOTES: When performing any of the arming commands, if there are faults in any of the partitions of a panel, the system will not arm that panel, but will arm all the other partitions of the other panels. When performing either a STAY or INSTANT arm command, the system always arms in mode 1 (see the VISTA-128BP/VISTA-250BP User Guide for a detailed explanation of the STAY and INSTANT arming modes). The user cannot execute another panel linking mode. In order to perform another panel linking mode or to access a different remote panel, the user must first exit this mode (return to the original control panel). Priority of Displays for Multi-Partition and Multi-Panel Modes This table shows the priority of displays if more than one of these conditions exists at the same time. Priority Description Display Priority Description Display 1 Fire Alarm F 8 Not Ready N 2 All Other Alarms ✴ 9 Ready R 3 AC Loss P 10 Armed STAY S 4 Comm Fail C 11 Armed AWAY A 5 System Low Battery L 12 Armed INSTANT I 6 Trouble T 13 Armed MAXIMUM M Section 3 - Installing the Control 2-7 7 Bypass B 3-1 SECTION 3 Installing the Control •••••••••••••••••••••••••••••••••••••••••••••••• • This section describes the procedures for mounting and wiring the control panel and all the peripheral devices. NOTE: All references in this manual for number of zones, number of user codes, number of access cards, and the event log capacity, use the VISTA-250BP’s features. See SECTION 1: General Description for the table listing the differences between the VISTA-128BP and the VISTA-250BP control panels. Mounting the Control Cabinet To mount the control cabinet, perform the following steps: Step Action 1 Before mounting the circuit board, remove the metal knockouts for the wiring entry that you will be using. DO NOT ATTEMPT TO REMOVE THE KNOCKOUTS AFTER THE CIRCUIT BOARD HAS BEEN INSTALLED. 2 Using fasteners or anchors (not supplied), mount the control cabinet to a sturdy wall in a clean, dry area that is not readily accessible to the general public. The back of the cabinet has 4 holes for this purpose. UL To provide certificated burglary service for UL installations, refer to the special requirements and Figure 3-2 Cabinet Attack Resistance Considerations to follow. For UL Commercial Burglary installations that require ATTACK RESISTANCE, use the cabinet included in the VISTA-ULKT kit. Installing the Cabinet Lock 1. Remove cabinet door, then remove the lock knockout from the door. Insert the key into the lock. 2. Position the lock in the hole, making certain that the latch will make contact with the latch bracket when the door is closed. 3. When correctly positioned, push the lock until it is held securely by its snap tabs. Use an ADEMCO No. K4445 Lock (supplied). CABINET DOOR BOTTOM LOCKED UNLOCKED ca b _ l o c k _ s n a p - 0 0 1 - V 0 AD E M C O AD E M C O PUSH SNAP TAB SNAP TAB PUSH ON LOCK UNTIL IT IS SEATED SECURELY STEP 2STEP 1 CHECK POSITION Figure 3-1: Installing the Lock Grade A Mercantile Premises Listing Guidelines • The panel door must be supervised. Mount the clip-on tamper switch (supplied) to the cabinet's right side wall as shown in the diagram below, and wire it to one of the hardwire zones. • Use a bell with a tamper-protected housing such as the ADEMCO AB12. The bell housing's tamper switch and inner tamper linings must also be wired to the hardwire zone. • Assign the tampers’ hardwire zone to a burglary partition. Program the hardwire zone for day trouble/night alarm (zone type 5) when only one burglary partition is used. Program it for 24-hr. audible alarm (zone type 7) when more than one burglary partition is used. • All wiring between the bell and panel must be run in conduit. Remaining wires do not need to be run in conduit. • All wiring that is not run in conduit must exit from the knockout openings on the bottom or back of the cabinet. • All unused knockouts must be plugged using the disc plugs and carriage bolts (supplied), as indicated in the diagram below. VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-2 • Fasten the cabinet door to the cabinet backbox using the 18 one-inch-long Phillips-head screws (supplied) after all wiring, programming, and checkout procedures have been completed. PC BOARD (Shows typical local Grade A listing installation) RUN BELL WIRES IN CONDUIT PLUG THIS KNOCKOUT PLUG THIS KNOCKOUT PLUG THIS KNOCKOUT PLUG THIS KNOCKOUT RUN ALL REMAINING WIRE THROUGH HERE CLIP-ON DOOR TAMPER SWITCH CABINET MOUNTING HOLE (4 PLACES) TO PLUG AN UNUSED KNOCKOUT OPENING, REMOVE KNOCKOUT AND INSTALL A PAIR OF DISC PLUGS AND A CARRIAGE BOLT AS SHOWN. KNOCKOUT OPENING HEX NUT AND WASHER DISC PLUGS (DIMPLES IN DISC PLUG SHOULD REGISTER INSIDE KNOCKOUT OPENING) CARRIAGE BOLT CABINET SIDE WALL (OUTSIDE) cabattack-001-V0 Figure 3-2: Cabinet Attack Resistance Considerations Grade A Mercantile Safe and Vault Listing Guidelines • Follow the guidelines given above for Grade A Mercantile Premises listing. • Mount a shock sensor such as Sentrol No. 5402 to the control's backbox. Follow the manufacturer's instructions for proper sensor mounting. This sensor also must be wired to a hardwire zone. • For safe and vault applications, a UL Listed contact must be used inside the cabinet through one of the knockouts for pry-off tamper purposes. This sensor also must be wired to a hardwire zone. Installing the Control's Circuit Board To install the circuit board in the cabinet, perform the following steps: Step Action 1 Hang the three mounting clips on the raised cabinet tabs. Refer to Figure 3-3 (Detail B). Make sure the clip orientation is exactly as shown in the diagram to avoid damage. This will also avoid problems with insertion and removal of the PC board. 2 Insert the top of the circuit board into the slots at the top of the cabinet. Make certain that the board rests in the slots as indicated (Detail A). 3 Swing the base of the board into the mounting clips and secure the board to the cabinet with the accompanying screws. Notes: • Make certain that the mounting screws are tight. This ensures that there is a good ground connection between the PC board and the cabinet. • Dress field wiring away from the microprocessor (center) section of the PC board. Use the loops on the left and right sidewalls of the cabinet for anchoring field wiring using tie wraps (Detail C). These steps are important to minimize the risk of panel RF interference with television reception. + + + DETAIL C SIDE VIEW OF SLOTS DETAIL A SIDE VIEW OF BOARD INSERTED INTO SLOTS DETAIL B SIDE VIEW OF SHORT MOUNTING CLIPS (TYP.) hi_end_mnt-PCB VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-4 Figure 3-3: Mounting the PC Board Installing the Keypads • Up to 31 addressable keypads (addresses 00-30) may be used (you may need to use an auxiliary power supply if the 750mA aux. output is exceeded). The following keypads may be used: • 2-line alpha display, 6139/6160/6160V NOTE: Refer to the Alpha Vocabulary list found in the #93 Menu Mode in the Programming Guide for list of the words annunciated by the 6160V. To wire the keypads, perform the following steps: Step Action Determine wire gauge by referring to the Wire Run Length/Gauge table below. Wire Run Length/Gauge Table Wire Gauge Length #22 gauge 450 feet #20 gauge 700 feet #18 gauge 1100 feet #16 gauge 1750 feet 1 2 Wire keypads to a single wire run or connect individual keypads to separate wire runs. The maximum wire run length from the control to a keypad, which is homerun back to the control must not exceed the lengths listed in the table. 3 Run field wiring from the control to the keypads (using standard 4-conductor cable of the wire gauge determined in step 1). 4 Connect the keypad(s) to terminals 6, 7, 8, and 9 on the control board, as shown in Figure 3-4. • The length of all wire runs combined, regardless of the wire gauge, must not exceed 2000 feet when unshielded quad conductor cable is used (1000 feet if unshielded cable is run in conduit, which acts a shield, or if shielded cable is used). • If more than one keypad is wired to one run, then the above maximum lengths must be divided by the number of keypads on the run (e.g., the maximum length is 225 feet if two keypads are wired on a #22 gauge run). KEYPADS BLACK RED GREEN YELLOW CONTROL TERMINALS 6 7 8 9 Figure 3-4: Keypad Connections to Control Panel VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-4 Addressing the Keypads The keypads will not operate until they are physically addressed and enabled in the system's Device Programming in the #93 Menu Mode. Set each keypad for an individual address (00-30) according to the keypad's instructions. Set an alpha keypad for address 00 and other keypads for higher addresses (00 and 01 are enabled in the system's default program). Any keypads set for address 02 and above will appear blank until they are enabled in the system's program. Each keypad must be set for a different address. • Do not set any keypads to address 31 (nonaddressable mode). They will interfere with other keypads (as well as other devices) connected to the keypad terminals. • If an “OC” or “OPEN CIRCUIT” message is present on a keypad, data from the control is not reaching the keypad. Check your wiring. Supplementary Power Supply for Additional Keypads When the control’s auxiliary power load for all devices exceeds 750mA, you can power additional keypads from a regulated 12VDC power supply (e.g., ADEMCO AD12612 (1.2A)). Use a UL Listed, battery-backed supply for UL installations. Connect the additional keypads as shown in Figure 3- 5, using the keypad wire colors shown. Be sure to observe the current ratings for the power supply used. • Make connections directly to the screw terminals as shown in Figure 3-5. Make no connection to the blue wire (if present). • Be sure to connect the negative (–) terminal on the power supply unit to terminal 7 (–) on the control. +–+ 6789 SUPPLEMENTARY POWER SUPPLY – CONTROL TERMINAL STRIP AUX.AUX.DATA IN DATA OUT IMPORTANT: MAKE THESE CONNECTIONS DIRECTLY TO SCREW TERMINALS AS SHOWN. RE D W I R E BL A C K W I R E YE L L O W W I R E GR E E N W I R E BL A C K W I R E RE D W I R E GR E E N W I R E YE L L O W W I R E pw r _ s u p p l y - 0 0 2 - V 0 TO MAIN KEYPAD TO SECONDARY KEYPAD Figure 3-5: Using A Supplementary Power Supply Installing External Sounders The VISTA-128BP/VISTA-250BP provides a bell circuit output for operating fire and burglary alarm notification appliances. The alarm output is rated as follows: 10VDC – 14VDC, 1.7A max., power-limited. UL • For Household Fire and combination Household Fire/Burglary installations, the total current drawn from the auxiliary power, polling loop, and alarm output combined must not exceed 750mA. • For Household Burglary installations, the total current drawn from the alarm output must not exceed 1.7A. A battery must be installed, as it supplies the current for the combined auxiliary power, polling loop, and alarm output in excess of 750mA. The output has the following options: • Selectable for supervision. • Selectable for confirmation of arming ding. • Selectable to chime when entry/exit or perimeter zones are faulted. • Selectable for no timeout or timeout of 2-30 minutes. UL Burglary bell circuits must be programmed for a timeout of 16 minutes or longer. UL985 Household Fire or Combination Household Fire/Burglary Installations For installations that must provide UL Listed protection, the total combined current drawn from the alarm output, auxiliary power output, and polling loop must not exceed 750mA in order to comply with the battery independence requirements. If, for example, two System Sensor PA400 piezo alarm sounders, wired in parallel, are used (24mA total), then 726mA (750mA – 24mA) is available for auxiliary output and polling loop use. UL1023 Household Burglary Installations For Household Burglary installations, the total current drawn from the alarm output must not exceed 1.7A. A battery must be installed, as the battery supplies current from the combined auxiliary power, polling loop, and alarm output in excess of 750mA. Non-UL Installations For non-UL installations, the total current drawn from this output can be up to 1.7 amps. A battery must be installed, as the battery supplies current in excess of 750mA. Up to two 719 sirens can be used wired in parallel. Section 3 - Installing the Control 3-5 UL This control complies with National Fire Protection Association (NFPA) requirements for temporal pulse sounding of fire notification appliances. Alarm Output Supervision When supervision is enabled, the VISTA- 128BP/VISTA-250BP monitors the alarm output wiring for open and short circuit faults while the output is inactive. The system provides a trouble indication (Zone 970) when an open occurs; or when a short occurs between the Bell (+) and Bell (-) terminal wiring, or between the Bell (+) terminal wiring and earth ground. UL NOTE: When supervising the bell output (zone 970), only one device can be connected to the alarm output (terminals 4 and 5) for UL and Fire installations. The VISTA-128BP/VISTA-250BP indicates the trouble condition regardless of whether the system is armed or disarmed. The zone displays on the keypads, reports to the event log, and transmits to the central station (if programmed) on Partition 1. The Contact ID event code is 321, Bell Trouble. The trouble is cleared from the display by entering the user code + OFF. Wiring the Alarm Output The wiring of the alarm output depends upon whether you are going to supervise the output or not. Use the appropriate procedure below for your application. UL Use only UL Listed sounding devices for UL installations. Compatible Alarm Indicating Devices Model Number Device Type Polarizing Diode 719 Compact Outdoor Siren (not UL Listed) Yes 747 Indoor Siren Yes AB12 Grade A Bell Yes System Sensor MA 12/24D Fire Piezo Horn No System Sensor P12575 Fire Horn/Strobe No Wheelock AS-121575W Fire Horn/Strobe No ALARM SOUNDER OUTPUT:1-VDC - 13.8VDC1.7A MAXIMUM BELL HORN 76 +- +-83124 fir e _ d e v i c e s - 0 0 1 - V 0 5 Figure 3-6: Wiring Polarized Fire Devices PANEL BELL PANEL BELL TO OTHER DEVICES NONPOLARIZED BURGLARY INDICATING DEVICES POLARIZED FIRE INDICATING DEVICE POLARIZING DIODES (MUST MOUNT AT INDICATING DEVICE) BELL BELL HORN non_polar_devices Figure 3-7: Wiring Nonpolarized Burglary Devices Supervising the Alarm Output To wire the alarm output using the supervision feature, perform the following steps: Step Action 1 Wire polarized fire-indicating devices to the alarm output as shown in Figure 3-6. 2 Wire nonpolarized burglary indicating devices to the alarm output using a polarizing diode (two 2A diodes supplied), as shown in Figure 3-7. 3 Program Zone 970 with a response type of 05 (trouble by day/alarm by night). NOTE: When supervising the bell output (zone 970), only one device can be connected to the alarm output (terminals 4 and 5) for UL and Fire installations. The minimum load on the alarm output must exceed 5mA at 12V for proper supervision operation. UL If a device such as a siren driver with a high- resistance trigger input (drawing less than 5mA) is used in a UL Household Fire installation, the siren driver must independently supervise siren speaker wiring. Section 3 - Installing the Control 3-5 Using a Siren Driver To install a siren driver, perform the following steps: Step Action 1 Mount the siren driver in the panel’s cabinet. 2 Wire the siren driver to the control and to the speaker(s). (See the driver’s instructions.) 3 Cut the blue jumper on the upper left-hand corner of the panel’s PC board. 4 Program Zone 970 with no response type (00). Disabling the Supervision of the Alarm Output To install the alarm output and disable the supervision feature, perform the following steps: Step Action 1 Wire the devices to terminals 4 and 5, observing polarity if necessary. 2 Cut the blue jumper on the upper left-hand corner of the panel’s PC board. 3 Program Zone 970 with no response type (00). Telephone Line Connections Connect the main dialer output to telephone company lines using the RJ31X cables supplied. UL The telephone line inputs have overvoltage protection in accordance with UL1459, as specified in UL985/UL1023. The system is shipped defaulted for Contact ID format. It is the only format capable of uniquely reporting all 250 zones, as well as openings and closings for all 250 users. This requires central stations to be equipped with the ADEMCO 685 receiver using software level 4.10 or higher. If you need an update, contact your distributor. To prevent the risk of shock, disconnect phone lines at the telco jack before servicing. If the communicator is connected to a PABX, be sure it has a backup power supply that can support the PABX for 24 hours (central station) or 60 hours (remote station). Many PABXs are not power-backed up, and this can result in a communication failure if power is lost. Reporting Formats The system supports the following formats: ADEMCO Low Speed 3+1; 4+1; 4+2; Sescoa/Radionics 3+1; 4+1; 4+2; ADEMCO 4+2 Express; ADEMCO High Speed; ADEMCO Contact ID TERMINALS ON CONTROL EARTH GROUND INCOMING TELCO LINE Handset TI P RI N G RJ31X JACK PLUG DIRECT CONNECT CORD TIP RING GR O U N D PREMISES PHONES {{ BR O W N ( T I P ) GR E Y ( R I N G ) GR E E N ( T I P ) RE D ( R I N G ) 2627282930 Incoming Telco Line Figure 3-8: Telephone Line Connections Wiring Burglary, Panic and Smoke Detector Devices to Zones 1-9 VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-6 The maximum zone resistance is 100 ohms for zones 1 and 8, and 300 ohms for all other zones (excluding the 2K EOL resistor). To wire burglary and panic devices to zones 1-9, connect sensors/contacts to the hardwire zone terminals (10 through 23). See Figure 3-9. Connect N.C. and N.O. devices as follows: • Connect N.C. devices in series with the high (+) side of the loop. The 2K EOL resistor must be connected in series with the devices, following the last device. • Connect N.O. devices in parallel (across) the loop. The 2K EOL resistor must be connected across the loop wires at the last device. ++- N.C.N.C. N.O. 2k EOLR2k EOLR +-++- N.C.N.C. 2k EOLR2k EOLR ++- N.C. ++- N.C.N.C. 2k EOLR SMOKE Zone resistance (Excluding EOLR): ZONE 1,8: 100 OHMS MAXIMUM ALL OTHER ZONES: 300 OHMS MAXIMUM ZONE 1 ZONE 2ZONE 3ZONE 4ZONE 5ZONE 6ZONE 7ZONE 8ZONE 9 2- W I R E S M O K E DE T E C T O R L O O P ( A l s o s u p p o r t s N O / N C B u r g c o n t a c t s ) LA T C H I N G T Y P E G L A S S BR E A K D E T E C T O R S 1011121314151617181920212223 N.C. N.O. N.O.N.O. 2k EOLR N.O.N.O. N.O. N.C. N.O. 2k EOLR 2k EOLR N.C. GLASS BREAKFireUsage Burg.Usage Red Jumper Zone response time:ZONES 1-9: 350mSec-500mSecZONE 9: Also Programmable for RS232 inputhw - z o n e s - 0 0 2 - V 0 Figure 3-9: Wiring Connections for Zones 1-9 Using 2-Wire Smoke Detectors on Zone 1 Zone 1 can support up to 16 2-wire smoke detectors. The alarm current on zone 1 supports only one smoke detector in the alarmed state. Compatible 2-Wire Smoke Detectors DETECTOR TYPE DEVICE MODEL # Photoelectric, direct-wire System Sensor 2400 Photoelectric w/heat sensor, direct-wire System Sensor 2400TH Photoelectric w/B401B base System Sensor 2451 Photoelectric w/heat sensor & B401B System Sensor 2451TH Ionization, direct-wire System Sensor 1400 Ionization w/B401B base System Sensor 1451 Photoelectric duct detect (DH400 base) System Sensor 2451 Photoelectric duct detect (DH400 base) System Sensor 2451 Ionization duct detector (DH400 base) System Sensor 1451DH Ionization, direct-wire System Sensor 1100 Ionization w/B110LP base System Sensor 1151 Photoelectric, direct-wire System Sensor 2100 Photoelectric w/heat sensor, direct-wire System Sensor 2100T Photoelectric w/B110LP base System Sensor 2151 UL These smoke detectors are UL Listed for use with the VISTA-128BP/VISTA-250BP and are the only 2-wire smoke detectors that may be used. Wiring 2-Wire Smoke Detectors to Zone 1 2K EOL resistors must be used on fire zones and must be connected across the loop wires of each zone at the last detector. To wire 2-wire smoke detectors to zone 1, perform the following steps: Step Action 1 Select up to 16 2-wire smoke detectors from the list of compatible detectors. 2 Connect 2-wire smoke detectors across zone 1 terminals (10 and 11) as shown in Figure 3-10. Observe proper polarity when connecting the detectors. 3 Connect the EOL resistor at the last detector in the loop across the zone 1 terminals. The EOL resistor must be connected across the loop wires at the last detector. VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-8 2k E O L R ZO N E 1 SM O K E (+) (-) 2-WIRE SMOKE DETECTOR 10 11 (+) (-) Figure 3-10: 2-Wire Smoke Detector on Zone 1 Using 4-Wire Smoke Detectors on Zones 1-8 You may use as many 4-wire smoke detectors as can be powered from the panel's Auxiliary Power output without exceeding the output's rating (750mA). • NFPA limits the number of 4-wire smoke detectors to 18 per zone. • Auxiliary power to 4-wire smoke detectors is not automatically reset after an alarm, and therefore must be momentarily interrupted using either the J7 smoke detector reset output trigger or a 4204 Relay Module. Compatible 4-Wire Smoke Detectors Use any UL Listed 4-wire smoke detector that is rated for 10-14VDC operation and that has alarm reset time not exceeding 6 seconds. Some compatible 4-wire smoke detectors are listed below. Detector Type Detector Model # Photoelectric, direct wire System Sensor 2412 Photoelectric w/heat sensor, direct wire System Sensor 2412TH Ionization, direct wire System Sensor 1412 Wiring 4-Wire Smoke Detectors UL Power to 4-wire smoke detectors must be supervised with an EOL device (use a System Sensor A77-716B EOL relay module connected as shown in Figure 3-11). To wire 4-wire smoke detectors to zones 1-8, perform the following steps: Step Action 1 Select 4-wire smoke detectors (see list of compatible detectors shown previously). 2 Connect detectors (including heat detectors, if used) across terminals of the zone selected. All detectors must be wired in parallel. See Figure 3-11. NOTE: If you are using the J7 output trigger to reset the smoke detectors, refer to Smoke Detector Reset on page 3-20 later in this section for the wiring instructions. 3 Connect the EOLR at the last detector in the loop across the zone’s terminals. You must connect the EOLR across the loop wires at the last detector. + + + + + HEAT DETECTOR 4-WIRESMOKEDETECTORS V128BP-002-V0 NO CONNECTION C NC NO RESET RELAY 1, 2, 3, OR 4 4204 RELAY MODULE NOTES: · PROGRAM THE RELAY TO TRANSFER ON FIRE ZONE RESET (ACTIVATION CODE 54). SEE 4204 RELAY MODULE SECTION FOR DETAILS. · SECOND CODE AND OFF ENTERED AT CONSOLE MOMENTARILY INTERRUPTS DETECTOR POWER. SHOWN POWERED. RELAY OPENS WHEN POWER IS LOST. EOL POWER SUPERVISION RELAY MODULE A77-716B 2kEOLR TO FIRE ZONE TERMINALS TO AUXILIARYPOWERTERMINALS Figure 3-11: 4-Wire Smoke Detectors Using Smoke Power Reversal Module The 333 PRM Polarity Reversing Module is used to reverse the polarity of the positive and negative voltages powering smoke detectors. The module is for use with 4-wire smoke detectors that employ a sounder and voltage-reversing feature. The module is triggered by a pulsing bell output. Smoke Detectors Compatible with the 333PRM The 333PRM may be used with the System Sensor 2112/24AT and similar models with the required operating features previously stated. VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-2 The 333PRM reverses polarity to smoke detectors with Integral Temp-3 Sounders. Typically, in alarm, each draws 49-60mA of current. The control panel supplies only enough current for one smoke detector. In order to attach more than one, an external power supply and an external relay may be required. Installing the 333 PRM Mount the 333 PRM inside the control panel’s cabinet or in a separate cabinet using the double-sided tape provided. Wire the 333PRM as shown in Figures 3-12a, b or c. Refer to the 333PRM Installation Instructions for detailed information on the installation of the module. -+ - + - + EOL POWER SUPERVISIONRELAY MODULEA77-761B 4-WIRE SMOKE DETECTORS 2000OHM EOLR TO FIRE ZONETERMINALS HEAT DETECTOR +– SHOWN POWERED. RELAY OPENS WHEN POWER IS LOST 33 3 P R M - 0 0 1 - V 0 33 3 P R M 7 6 5 4 3 -2 +1 8 JUMPER P1 NC MOMENTARY RESET SWITCH JUMPER P1 ON333 MODULE MUST BE IN "B" POSITION FOUR-WIRE DETECTOR CIRCUIT CONTROL PANEL 746 Figure 3-12a: Wiring a 333PRM to the Control -+ - + - + EOL POWER SUPERVISION RELAY MODULEA77-761B 4-WIRE SMOKEDETECTORS 2000 OHMEOLR TO FIRE ZONETERMINALS HEATDETECTOR +– SHOWN POWERED. RELAY OPENS WHEN POWER IS LOST 33 3 P R M - 0 0 2 - V 0 33 3 P R M 7 6 5 4 3 -2 +1 8 JUMPER NCCNO P1 JUMPER P1 ON 333 MODULEMUST BE IN"B" POSITION FOUR-WIRE DETECTOR CIRCUIT 4204 CONTROL PANEL 2 3 41 12 76 4 Figure 3-12b: Wiring a 333PRM using a 4204 Section 3 - Installing the Control 3-9 -+ - + - + EOL POWER SUPERVISION RELAY MODULEA77-761B 4-WIRE SMOKEDETECTORS 2000OHMEOLR TO FIRE ZONE TERMINALS HEATDETECTOR +– SHOWN POWERED. RELAY OPENS WHEN POWER IS LOST 33 3 P R M - 0 0 3 - V 0 PO W E R SU P P L Y 33 3 P R M 7 6 5 4 3 + -2 +1 8 JUMPER P1 USE A 12VDC,BATTERY-BACKED,UL LISTED POWERSUPPLY. JUMPER P1 ON333 MODULE MUST BE IN"B" POSITION FOUR-WIRE DETECTOR CIRCUIT 42 0 4 CONTROL PANEL 2 3 4 1 12 76 4 Figure 3-12c: Wiring a 333PRM using a 4204 and a Power Supply Using 2-Wire Latching Glassbreaks on Zone 8 Zone 8 can support 2-wire glassbreak detectors. The zone provides enough standby current to power up to 50 2-wire glassbreak detectors meeting the requirements listed below. Compatible Glassbreak Detectors Use detectors that meet the following ratings: Standby Voltage: 5VDC–13.8VDC Standby Resistance: Greater than 20k ohms (equivalent resistance of all detectors in parallel) Alarm Resistance: Less than 1.1k ohms (see note below) Alarm Current: 2mA–10mA Reset Time: Less than 6 seconds NOTES: • You can use detectors that exceed 1.1k ohms in alarm, provided they maintain a voltage drop of less than 3.8 volts in alarm. • The ADEMCO ASC-SS1 detector has been tested and found to be compatible with these ratings. 21 22 GLASSBREAK DETECTOR ZONE 8 (+) (-) LATCHING TYPE GLASS BREAK DETECTOR LOOP 2000 OHMS EOLR Figure 3-13: Wiring Latching Glassbreaks to Zone 8 • The alarm current provided by zone 8 supports only one glassbreak detector in the alarmed state. • Do not use other contacts when using glassbreak detectors on zone 8. Other contacts may prevent proper glassbreak detector operation. To wire 2-wire latching glassbreak detectors to zone 8, perform the following steps: Step Action 1 Select 2-wire glassbreak detectors that meet the requirements stated previously. 2 Connect detectors across zone 8 (terminals Section 3 - Installing the Control 3-11 21 and 22). See Figure 3-13. 3 Connect the EOL resistor at the last detector in the loop across the zone’s terminals. You Tamper Supervision for the Hardwired Zones The system can be programmed to monitor for either an open condition or a short condition of a tamper switch on zones 1-8. End-of-line supervision is required for this option. Wiring a Tamper Switch to Zones 1-8 The wiring of the tamper switch depends on whether the tamper switch and the sensor are normally open or normally closed. • If you are using a normally closed sensor, the tamper switch must be normally open. Refer to Figure 3-14 for the wiring configuration. • If you are using a normally open sensor, the tamper switch must be normally closed. Refer to Figure 3-15 for the wiring configuration. • For the normally closed sensor, program the zone for trouble on short. For the normally open sensor, program the zone for trouble on open. To wire a tamper switch on a hardwired zone, connect the EOL resistor at the last detector in the loop across the zone’s terminals. You must connect the EOL resistor at the last detector for proper operation of the tamper supervision. NOTE: For zones with a response type of 9 or 16 (Fire), the tamper selection must be “0” none. 2k EOLR + TAMPER SWITCH SENSOR Figure 3-14: Wiring a Normally Closed Loop for Tamper Supervision 2k EOLR + TAMPER SWITCH SENSOR Figure 3-15: Wiring a Normally Open Loop for Tamper Supervision Installing RPM Devices The polling loop provides both power and data to the RPM devices, and is constantly monitoring the status of all zones enabled on the loop. The maximum current draw of all devices on the polling loop cannot total more than 128mA (unless the system uses a 4297 Polling Loop Extender Module). Devices that can be programmed via either DIP switches or the built-in unique serial number must be set for the serial number mode operation. All devices on the polling loop must be wired in parallel to the [+] and [-] polling loop terminals of the control panel (24 and 25). You can wire from device to device, or have multiple branches connected directly to the control panel in a star configuration. Compatible Polling Loop Devices Model Number Type 4208 8-Zone Expander 4190WH 2-Zone Expander 4278 Quad PIR 4275 Dual PIR 4194 Surface-Mount Reed Contact (Wide Gap) 4297 Extender Module 4192SD Photoelectric Smoke Detector Devices 4192SDT Photoelectric Smoke Detector w/Heat Detector 4192CP Ionization Smoke Detector 4101SN Serial Number Single-Output Relay Module VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-12 4208U Universal 8-Zone Expander 4939SN-BR 4939SN-GY Serial Number Surface-Mount Reed Contacts 4191SN-WH Serial Number Recessed Reed Contact 4959SN Aluminum Overhead Door Contact 7500 Single Technology Glassbreak Detector 9500 Dual Technology Glassbreak Detector 4209U Universal Group Zoning Module 4193SN Serialized 2-Zone Expander 4293SN Serialized 1-Zone Expander 4190SN Serialized 2-Zone Expander 998MX Serialized PIR UL • The 4208 must be mounted either inside the control panel’s cabinet or in a separate enclosure that has a tamper-supervised cover. • The 4190WH right loop must not be used, and the left loop must be EOLR-supervised. • The 4278 right loop cannot be used. • The 4194 is not UL Listed. • The 4297 must be powered from the control panel’s Auxiliary Power Output or from a UL Listed supplementary power supply. • The 7500 and 9500 detectors are not UL Listed. • For new polling loop installations, always use twisted pair wiring. In many cases, existing non-twisted pair wiring may be used, but it is more susceptible to interference from other sources, and may be problematic in installations with long wire runs or in high noise environments. • Always locate polling loop wiring at least six inches (15cm) of AC power, telephone, or intercom wiring. The polling loop carries data between the control panel and the devices; interference on this loop can cause an interruption of communication. The polling loop can also cause outgoing interference on the intercom or phone lines. If this spacing cannot be achieved, shielded wire must be used. (Note that the maximum total wire length supported is cut in half when shielded wire is used.) • No more than 64mA may be drawn on any individual wire run. • When a star configuration is used, the total length of all wire runs combined cannot exceed 4000 ft (2000 ft. if you are using unshielded wire in conduit or shielded wire). IMPORTANT NOTE: If the installation needs to exceed or deviate from these parameters, refer to the application note on the Honeywell website for additional polling loop wiring configurations. To access the application note: 1. Go to the honeywell.com/security website 2. Click the Honeywell Security & Custom Electronics link. 3. Click the Commercial link. 4. Click the Documentation link. 5. Click the V-Plex Application Note. Section 3 - Installing the Control 3-13 To install polling loop devices, perform the following steps: Step Action 1 Select devices from the list of compatible devices shown previously. 2 Set the DIP switches in the device (if required). Refer to the device’s instructions. 3 Mount each device in the desired location. Refer to the device’s instructions. Run wires from the control panel to each device on the polling loop (see Figure 3-16). No individual wire run may exceed the lengths shown in the following table. Maximum Polling Loop Wire Runs Wire Gauge Max. Length #22 gauge 650 feet #20 gauge 950 feet #18 gauge 1500 feet #16 gauge 2400 feet 4 5 Wire each device to the polling loop, making sure of the correct polarity (refer to the device’s instructions). NOTE: If you are using serial number devices, and intend to enroll each device through the keypad automatically, wire no more than 25 of these devices to the control at a time. Then power up and program them before connecting the next 25. Leave previously enrolled devices connected. If you intend to manually enter the serial numbers via the keypad or the Compass downloading software, all the devices may be connected before powering up to program. POLLING LOOP RATING: 128mA MAXIMUM 4192SD SMOKE 4190RPM 4278PIR 232122 +- PO L L I N G L O O P 2524 TO RIGHT LOOP po l l _ l o o p - 0 0 1 - V 0 Figure 3-16: Polling Loop Connections to the VISTA-128BP/VISTA-250BP Polling Loop Supervision A short on the polling loop is indicated by a trouble on zone 997 and reports as a trouble condition only. If annunciation is desired, program the zone as type 05. If a device on the polling loop fails (the panel cannot "see" that device), the system displays a trouble condition for all zones on that device. If the panel is armed when a device fails, and the zone is a burglary zone, the will go into alarm A trouble on zone 997 prevents a partition from being armed, unless all polling loop zones on that partition are bypassed. Using the 4297 Polling Loop Extender The 4297 Polling Loop Extender may be used to provide additional polling loop current, to extend the polling loop wire run length, and/or to provide individual electrically isolated polling loops. Refer to Figures 3-17 and 3-18, to follow. DO NOT use the 4197 Polling Loop Extender module with the VISTA-128BP/VISTA-250BP. Be sure to include the total current drawn on the polling loop when figuring the total auxiliary load on the panel’s power supply. Section 3 - Installing the Control 3-13 CONTROL PANEL RPM INPUT POLLING LOOP EXTENSION POLLING LOOP RPM 4297 RPM RPM TO OTHER RPMS INPUT LOOP LIMITS: EXTENSION POLLING LOOP LIMITS = SAME AS INPUT LOOP •128 mA MAX. LIMIT CURRENT TO 64mA ON ANY INDIVIDUAL WIRE RUN. • NO MORE THAN 64 DEVICES MAY BE USED. NO INDIVIDUAL WIRE RUN CAN EXCEED: • • TOTAL LENGTH OF ALL WIRE RUNS COMBINED CANNOT EXCEED 4000FT. (2000FT. IF USING SHIELDED WIRE) GAUGE LENGTH #22 650 FT #20 950FT #18 1500 FT #16 2400 FT • NO MORE THAN119 DEVICES COMBINED. • TOTAL LENGTH OF ALL WIRE RUNS ON BOTH LOOPS COMBINED CANNOT EXCEED 6400 FT. 3200 FT. IF USING UNSHIELDED WIRE IN CONDUIT, OR IF USING SHIELDED WIRE po l l i n g _ l o o p _ 0 0 3 - V 2 COMBINED INPUT AND EXTENSION LOOP LIMITS: Figure 3-17: Polling Loop Connections Using One 4297 Extender Module CONTROL PANEL EXTENSION POLLING LOOP #1 4297 RPM COMBINED INPUT AND EXTENSION LOOPLIMITS: • NO MORE THAN 119 DEVICES COMBINED ON THE INPUT LOOP AND EXTENSION LOOP #1. NO MORE THAN 119 DEVICES COMBINED ON THE INPUT LOOP AND EXTENSION LOOP #2. • TOTAL LENGTH OF ALL WIRE RUNS ON THE INPUT LOOP AND EXTENSION LOOP #1 COMBINED CANNOT EXCEED 6400 FT. (3200 FT. IF USING UNSHIELDED WIRE IN CONDUIT, OR SHIELDED WIRE). TOTAL LENGTH OF ALL WIRE RUNS ON THE INPUT LOOP AND EXTENSION LOOP #2 COMBINED CANNOT EXCEED 6400 FT. (3200 FT. IF USING UNSHIELDED WIRE IN CONDUIT, OR SHIELDED WIRE). 4297 RPM INPUT POLLING LOOP • DO NOT CONNECT 4297 MODULES IN SERIES (i.e., DO NOT CONNECT ONE MODULE'S EXTENSION LOOP TO ANOTHER MODULE'S INPUT LOOP.) po l l i n g _ l o o p - 0 0 4 - V 1 EXTENSION POLLING LOOP #2 Figure 3-18: Polling Loop Connections Using Multiple Extender Modules NOTE: The input loop limits stated in Figure 3-17 apply to Figure 3-18 as well. Wireless Zone Expansion UL The 5881ENHC RF Receiver and the 5869 Holdup Switch Transmitter are listed for UL Commercial Burglary applications. All other RF receivers and transmitters are not listed for UL Commercial Burglary applications. The following table lists the receivers that may be used and the number of zones they support. 5800 Series Receivers Receiver Zones 5881L up to 8 5881M up to 16 5881H up to 250 In Canada, 5800 systems must use 5882 Series receivers: 5882L/5882H. Information to the 5881 Receivers applies as well to the 5882 Receivers. Both receivers use the same transmitters. RF System Operation and Supervision The 5800 RF system operation has the following characteristics: • The receiver responds to a frequency of 345MHz. • The receiver has a nominal range of 200 feet. • Supervised transmitters send a supervisory signal every 70-90 minutes. VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-14 • Zones 988 and 990 are used to supervise the RF reception of receivers 2 and 1, respectively. The reception is supervised for two conditions: 1. The receiver goes “deaf” (doesn’t hear from any transmitter) within a programmed interval of time (defined by program field 1*30). 2. Proper RF reception is impeded (i.e., jamming or other RF interference). The control checks for this condition every 45 seconds. UL A response type (05 Day/Night) must be programmed for zones 990 (1st receiver) and 988 (2nd receiver) for UL installations. • The 5881ENHC receiver contains front and back tampers that permit its use in commercial burglary installations. • You may only mount the 5881ENHC its own plastic housing. Otherwise, the receiver constantly reports a tamper condition. • The control checks the receiver connections about every 45 seconds. The receiver supervisory zone is 8 + 2-digit receiver device address (for example, Device address 05 = supervisory zone 805). NOTE: This zone must be programmed with a response type (e.g., type 05 Day/Night Trouble) before it supervise the connection to the receiver. • Use two identical receivers to provide either a greater area of coverage or redundant protection. They must be set for different addresses. • Any zone from 1 to 250 can be used as a 5800 Series wireless zone, with the exception of zone 64 (reserved for a wireless keypad). RF System Installation Advisories • Place the receiver in a high, centrally located area. Do not place it on or near metal objects. This will decrease the range and/or block transmissions. • Install the RF receiver at least 10 feet from the control panel or any keypads, to avoid interference from the microprocessors in these units. • If dual receivers are used: a. They must be at least 10 feet from each other, as well as from the control panel and remote keypads. b. Each receiver must be set to a different device address. The receiver set to the lower address is considered the 1st RF receiver for supervisory purposes. c. The House IDs must be the same. d. Using two receivers does not increase the number of transmitters the system can support (249 zones using the 5881H, plus a wireless keypad). Installation and Setup of 5881 RF Receivers Take note of the address you select for the RF receiver, as this address must be enabled in the system’s Device Programming in the #93 Menu Mode. 5881ENHC-001-V0 SCREW Figure 3-19: Installing the 5881ENHC with Tamper Protection To install the 5881 RF receiver, perform the following steps: Step Action 1 Mount the receiver, following the advisories stated previously. 2 Set the DIP switches in the receiver for the address (01-07). See Figure 3-20. Make sure the address setting is not being used by another device (keypad, relay module, etc.). 3 If installing a 5881ENHC, install a flat-head screw (supplied) in the case tamper tab as shown in Figure 3-19. When the receiver is pried from the wall, the tamper tab will break off and remain on the wall. This will activate a tamper switch in the receiver and cause generation of a tamper signal. Note that this signal will also be generated when the receiver’s front cover is removed. 4 Connect the receiver’s wire harness to the keypad terminals (6, 7, 8, and 9). Plug the connector at the other end of the harness into the receiver. 5 Refer to the Installation Instructions provided with the receiver for installations regarding antenna mounting, etc. Section 3 - Installing the Control 3-15 TO CONTROL'S REMOTE KEYPAD CONNECTION POINTS. USE MAX. of 220 ft. [67m of #22 (0.64mm) WIRE or 550 ft. (168m) of #18 (1mm) WIRE FOR EACH RUN. OBSERVE 20 ft. MAX. FOR COMMERCIAL FIRE INSTALLATIONS. (SEE RECEIVER'S INSTRUCTIONS.) DIP SWITCH WHITE AREAS = SWITCH HANDLES. POSITION 2-4 DETERMINE RECEIVER'S ADDRESS. CONSULT CONTROL'S INSTRUCTIONS FOR ADDRESS TO USE. DIP SWITCH BELOW SHOWN SET FOR ADDRESS "0." SWITCH POSITION RECEIVER ADDRESS SETTINGS (" - " MEANS OFF) 0 1 2 3 4 5 6 7 4 3 2 1 5 PRESENT ONLY ON 5881EH (SEE TEXT AT LEFT) ONONON ONON ONONONON ONON ON FOR FUTURE USEDIP SWITCH #5 (PRESET ONLY ON 5881EH) ON: SETS 5881EH FOR USE IN COMMERCIAL FIRE APPLICATIONS (SEE THE RECEIVER'S INSTRUCTIONS)*. OFF: USE IN NON-COMMERCIAL FIRE INSTALLATIONS. * FOR COMMERCIAL FIRE APPLICATIONS THE 5881EH PC BOARD MUST BE MOUNTED IN A SEPARATE CABINET (SEE RECEIVER'S INSTRUCTIONS FOR DETAILS). MOUNTING HOLES INSERT IN RIGHT-HAND TERMINALS CIRCUIT BOARD DIP SWITCH YELLOW RED BLACK GREEN INTERFERENCE INDICATOR LED WIRING OPENING PLUG & SOCKET ANTENNAS 58 8 1 - 0 0 1 - V 1 Figure 3-20: 5881 RF Receiver (cover removed) Installing the 5800TM Module Installation of this module is necessary only if you are using a 5827BD or 5804BD Bi-directional device. The address for the 5800TM must be enabled in the control’s Device Programming in the #93 Menu Mode as a keypad and then assigned to a partition. To install the 5800TM, perform the following steps: Step Action 1 Mount the unit using its accompanying mounting bracket near the RF receiver. The 5800TM must not be installed within the control cabinet. It must be between one and two feet from the receiver’s antennas. 2 Set the module for the appropriate address. For Address Setting 28 cut the red jumper; for Address 29 cut the white jumper; for Address 30 cut both jumpers. Make sure the address setting is not being used by another device (keypad, relay module, etc.). 3 Connect the module’s wire harness to the keypad terminals (6, 7, 8, and 9). Plug the connector at the other end of the harness into the module. House ID Sniffer Mode This mode applies only if you are using a wireless keypad (e.g., 5827) or bi-directional devices (e.g., 5804BD). Use the House ID Sniffer mode to make sure you do not choose a House ID that is in use in a nearby system. The House ID must be programmed for the receiver in Device Programming in the #93 Menu Mode. To enter House ID Sniffer mode, enter your Installer Code + [#] + [2]. The receiver now “sniffs” for any House IDs in the area and displays them. Keep the receiver in this mode for 2 hours. Use a House ID that is not displayed. Exit the Sniffer mode by entering your Installer Code + OFF. As Sniffer mode effectively disables RF point reception, Sniffer mode cannot be entered while any partition is armed. 5800 Series Transmitter Setup 5800 Series transmitters have the following characteristics: • Transmitters have built-in serial numbers that must be enrolled in the system using the #93 Menu Mode Programming, or input to the control via the downloader. • Transmitters do not have DIP switches (except 5827, described separately). • Some transmitters, such as the 5816 and 5817, can support more than one “zone” (referred to as loops or inputs). Each loop must be assigned a different zone number. VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-16 • For button-type transmitters (wireless keys), such as the 5804 and 5804BD, you must assign a unique zone number to each individual button used on the transmitter. Transmitter Input Types All transmitters have one or more unique factory- assigned input (loop) codes. Transmitters can be programmed as one of the following types: Type Description RM (RF Motion) Sends periodic check-in signals, as well as fault and low-battery signals. The control panel automatically restores the zone to “ready” after a few seconds. This type is designed for facilities with multiple motion detectors that may fault and restore simultaneously. The transmitter must remain within the receiver’s range. NOTE: If using RF Motion with a door/window type transmitter, only loop 1 may be used. RF (Supervised RF) Sends periodic check-in signals, as well as fault, restore, and low-battery signals. The transmitter must remain within the receiver’s range. UR (Unsupervised RF) Sends all the signals that the RF type does, but the control does not supervise the check-in signals. The transmitter may therefore be carried off-premises. BR (Unsupervised Button RF) These send only fault signals. They do not send low-battery signals until they are activated. The transmitter may be carried off-premises. Transmitter Supervision Supervised RF transmitters send a check-in signal to the receiver at 70–90 minute intervals. If at least one check-in is not received from each supervised transmitter within a programmed period (field 1∗31), the “missing” transmitter number(s) and “CHECK” or “TRBL” are displayed. Unsupervised RF transmitters (5802MN, 5804) may be carried off the premises. Some transmitters have built-in tamper protection, and annunciate a “CHECK” or “TRBL” condition if covers are removed. If a loss of supervision occurs on a transmitter programmed for Fire, it reports in Contact ID as a Fire Trouble (373), not Loss of Supervision (381), to the central station. Transmitter Battery Life Batteries in the wireless transmitters may last from 4 to 7 years, depending on the environment, usage, and the specific wireless device being used. Factors such as humidity, high or low temperatures, as well as large swings in temperature may all reduce the actual battery life in a given installation. The wireless system can identify a true low battery situation, thus allowing the dealer or user of the system time to arrange a change of battery and maintain protection for that point within the system. Some transmitters (e.g., 5802, 5802CP, and 5803) contain long-life but nonreplaceable batteries. At the end of their life, the complete unit must be replaced (and a new serial number enrolled at the control). Button-type transmitters (e.g., 5801, 5802, 5802CP and 5803) should be periodically tested, as these transmitters do not send supervisory check-in signals. To test the transmitters using the Transmitter ID Sniffer mode and the Go/NoGo Test Mode, see SECTION 10: Testing the System for the procedures. Compatible 5800 Series Transmitters Model Product Input Type 5801 Panic Transmitter UR or RF 5802 5802CP Pendant (Personal Emergency Transmitter) Belt Clip (Personal Emergency Transmitter) BR Only 5802MN Miniature (Personal Emergency Transmitter) UR or RF 5802MN2 Miniature (Personal Emergency Transmitter) UR or RF 5804 Wireless Key Transmitter BR Only 5804BD Wireless Key Bi-directional Transmitter BR Only 5804BDV Wireless Key Bi-directional Transmitter with Voice BR Only Model Product Input Type 5806/5807/ 5808 Wireless Photoelectric Smoke Detectors RF 5816 Door/Window Transmitter RF 5816MN Miniature Door/Window Transmitter 5816TEMP Temperature Sensor Transmitter 5817 Multi-Point Universal Transmitter RF 5818 Recessed Transmitter RF 5827 Wireless Keypad House ID 5827BD Wireless Bi-directional Keypad House ID 5849 Glassbreak Detector RF 5850 Glassbreak Detector RF 5890 PIR Detector RF 5890PI PIR Detector with Pet Immunity RF Section 3 - Installing the Control 3-17 Installing Output Devices The VISTA-128BP/VISTA-250BP support up to 96 outputs. Each device must be programmed as to how to act (ACTION), when to activate (START), and when to deactivate (STOP). The 4204, 4204CF, FSA-8, FSA- 24, 4140SN and/or X-10 devices may be used as output devices. Installing 4204 and 4204CF Relay Modules Each 4204 module provides 4 relays with Form C (normally open and normally closed) contacts. Each 4204CF module adds two style Y supervised bell outputs to the system. For 4204CF modules, only relays 1 and 3 on each module can be programmed. The relay module will not operate until the device address you have set the DIP switches for is enabled in the control’s Device Programming in the #93 Menu Mode. To install the relay modules, see Figures 3-21 and 3-22 and perform the following steps: Step Action 1 Set the 4204 or 4204CF’s DIP switches for a device address 01-15. Do not use an address being used by another device (keypads, RF receivers, etc.). 2 Mount the 4204 and 4204CF Modules per the instructions provided with them. Connect the module’s wire harness to the control (6, 7, 8, and 9). Plug the connector (other end of harness) to the module. If you are mounting remotely, homerun each module to the control. The table below shows the maximum wire run lengths. Refer to the instructions provided with the 4204CF for its maximum permissible wire lengths. Wire Gauge Maximum Length #22 125 feet #20 200 feet #18 300 feet #16 500 feet 3 SWITCH4204 ADDRESS SETTINGS POSITION("—" means "OFF") 0123456789101112131415 2 ON —ON —ON —ON —ON —ON —ON —ON — 3 ONON ——ONON ——ONON ——ONON —— 4 ONONONON ————ONONONON ———— 5 ONONONONONONONON ———————— ON12 3 4 5 13141516 C NC NO OFF ON DIP SWITCHFOR SETTING DEVICE ADDRESS AND ENABLING/DISABLING TAMPER COVER TAMPER (REED)SWITCH TB1 4204 TB2 4-PIN CONSOLE PLUG 12 11 10 9 8 7 6 5 4 3 2 1 C NC NO C NC NO C NC NO RELAY 3 RELAY 2 RELAY 1 RELAY4 TYPICAL (SHOWN "OFF") EITHER OR BOTH CAN BE USED DATA INFROM CONTROL (–) GROUND DATA OUTTO CONTROL (+) 12V YEL BLK GRN RED Figure 3-21: 4204 Relay Module SWITCH4204CF ADDRESS SETTINGSPOSITION("—" means "OFF") 0123456789101112131415 2 ON —ON —ON —ON —ON —ON —ON —ON — 3 ONON ——ONON ——ONON ——ONON —— 4 ONONONON ————ONONONON ———— 5 ONONONONONONONON ———————— ON12 3 4 5 OFF ON 13141516 NC NC DIP SWITCH FOR SETTING DEVICE ADDRESS AND ENABLING/DISABLING TAMPER COVER TAMPER (REED)SWITCH TB1 TB2 4-PIN CONSOLE PLUG 12 11 10 9 8 7 6 5 4 3 2 1 NC NC NC NC EITHER OR BOTH CAN BE USED DATA INFROM CONTROL (–) GROUND DATA OUTTO CONTROL YEL BLK GRN RED (+) 12V; SUPPLIES POWER TO MODULECIRCUITRY (INCLUDING NOTIFICATIONAPPLIANCE RELAY COILS). CURRENTDRAIN AT 12V IS: 25 mA + (80 mA PER ACTIVE OUTPUT) NOTIFICATION APPLIANCE ANDCONSOLE DATA OUTPUTS AREPOWER LIMITED – + NOTIFICATIONAPPLIANCE B 2K EOLR #610-7 POLARIZED NOTIFICATIONAPPLIANCE– + NOTIFICATIONAPPLIANCE A 2K EOLR #610-7 }– +POWER FOR NOTIFICATION APPLIANCE A,NOTIFICATION APPLIANCE B8-28VDC OR VFW. UP TO 2.4ADEPENDING ON BELL CURRENT - ALARM POLARITYSHOWN - EACH OUTPUT PROVIDES STYLE Y SUPERVISION - EACH OUTPUTRATED 1.2A MAX - USE NOTIFICATION APPLIANCES COMPATIBLE WITH NOTIFICATION APPLIANCE POWER SUPPLY VOLTAGE RATING Figure 3-22: 4204CF Relay Module Installing FSA Modules The 8-zone LED Fire System Annunciator FSA-8 and 24-zone LED Fire System Annunciator FSA-24 enable a fire response unit to identify quickly the point/zone of a fire. These indicators may be used for other functions as well, such as status indication. A maximum of 4 FSA modules, in any combination, can be supported. The FSA module will not operate until the device address you have set the DIP switches for is enabled in the control’s Device Programming in the #93 Menu Mode. To install the FSA module, refer to Figure 3-23 and perform the following steps: Step Action 1 Set the FSA’s DIP switches for a device address from 08 to 23. See the module’s instructions for the DIP switch table. Do not use an address being used by another device (keypads, RF receivers, etc.). 2 Mount the FSA module horizontally to a duplex box (quad box for FSA-24). VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-18 3 Connect the module to the control’s keypad terminals (6, 7, 8, and 9). 00000 ECP Bus Dip SwitchOptional Keyswitch Connection SIDE VIEW All Switches shown in Up position. (ECP Address 23) Terminal Block Connect to Keypad Terminals Figure 3-23: Wiring the FSA Module Installing 4101SN Relay Modules The 4101SN V-Plex Single Output Relay Module is a serial number polling loop output device. The 4101SN features the following: • Form C relay contacts rated at 2A, 28VAC/VDC with contact supervision. The position of the relay is supervised, but not the actual external contact wiring. • One class B/style B EOLR-supervised auxiliary input zone. • Operating power and communication with control panels via the V-Plex polling loop. • Electronics mounted in a small plastic case with tamper-protected cover. Connect the device to the polling loop, terminals 24 (+) and 25 (-). Be sure to observe polarity Installing X10 Devices X-10 devices are either plugged into standard AC outlets or wired into the AC electrical system by a licensed electrician, depending on the type of device used. Note each device’s House and Unit Code setup, as these codes will be used to program the devices in Output Programming in #93 Menu Mode described in the Programming Guide. X-10 devices require the use of a 1361X10 transformer in place of the regular 1361 transformer. X-10 devices respond to “on” and “off” commands sent from the panel through the 1361X10 transformer. To connect the 1361X10 transformer, see Connecting the Transformer, later in this section. Installing the Ground Start Module UL The Ground Start Module is not intended for use in UL Listed applications. Output 1 may be used to trigger an optional 675 Ground Start Module for installations having telephone lines that require ground start instead of loop start operation to obtain a dial tone from the telco central office. When the panel has a message to transmit to the central station, it seizes the line, goes off hook, and then triggers the 675 Module to connect the RING side of the telephone line to earth ground. The panel causes the module to break the connection between RING and earth ground when it obtains a dial tone. You cannot use Output 1 for the Ground Start if you are using it for a Smoke Detector Reset or an AAV module. To install the 675 Ground Start Module, perform the following steps: Step Action 1 Determine which side of the telephone line is the RING side by connecting the (+) lead of a DC voltmeter to earth ground, and the (-) lead to one side of the telephone line. The wire that reads + 50VDC is the RING side. 2 Connect the 675 Ground Start Module to the panel’s J7 connector trigger output 1, to auxiliary power, and to the RING side of the telephone line as shown in Figure 3-24. VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-16 3 Program field 1✳46 Auxiliary Output Enable with a [0]. 12 3 4 5 6 7 8 9 4142TR CABLE GRAY (GROUND) YELLOW (OUT 1) RED (OUT 2) GREEN (GROUND) BROWN (OUT 3) BLUE (GROUND) BLACK (OUT 4) WHITE (GROUND) J7 CONNECTOR N/U IF USED: 1. OUT 1 IS NO LONGER USABLE FOR SMOKE DETECTOR RESET (SEE FIELD 1*46). 2. OUT 2, 3, 4 CAN STILL BE USED TO PROVIDE ALARM STATUS INDICATIONS OR TO OPERATE A KEYSWITCH (SEE FIELD *15). 3. THE 675 IS NOT UL LISTED. BR O W N GROUND START TRIGGER BLUE GR E E N BLACK VIOLET TO AUX. POWER TERM. 7 TO AUX. POWER TERM. 6 (50mA CURRENT DRAW) 675 GROUND START MODULE (CUT ORANGE JUMPER) TO TELCO RING TO EARTH GROUND Figure 3-24: Ground Start Module Connections Installing a Remote Keyswitch A UL-Listed remote keyswitch, such as the ADEMCO 4146, can be used for remote arming/disarming of the burglary portion of the system and for silencing alarms. The keyswitch can operate in only one particular partition. The keyswitch is wired across zone 7. This zone is no longer available as a protection zone. Be sure to program Zone 7 with a response type (e.g., type 10). Operation • A momentary short across zone 7 arms the partition in the AWAY mode, and a short held for more than 10 seconds arms the partition in STAY mode 1. A subsequent short disarms the partition. • The keyswitch LEDs indicate the partition’s status (see table below). • A momentary short across Zone 7 silences alarm bell and keypad sounds, and disarms the system if it was armed. A subsequent short across Zone 7 clears the alarm memory indication and resets 2- wire smoke and glassbreak detectors (if used). LED Indications Green Red Indication On Off Disarmed & Ready Off Off Disarmed & Not Ready Off On Steady Armed Away Off Slow Flash Armed Stay Off Rapid Flash Alarm Memory The keyswitch reports as user 0, if Open/Close reporting is enabled in field ✳40. Keyswitch Tamper Operation The tamper switch need not be used for fire or UL Household Burglary installations. For UL Commercial Burglary installations, the tamper switch must be wired to a zone (zone 6 in Figure 3-25). Program that zone for Day Trouble/Night Alarm (response type 5). When the keyswitch is removed from the wall, the tamper switch opens, causing an alarm or trouble on the zone. This also causes the control to disable keyswitch operation until the tamper is restored and the associated partition is disarmed. Wiring for the Remote Keyswitch To install the ADEMCO 4146 keyswitch, perform the following steps: Step Action 1 Connect the ADEMCO 4146 to the panel as shown in Figure 3-25. 2 If you are using the tamper, make sure it is connected to a zone. VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-20 2K ELOR 2K ELOR TAMPER SWITCH(CONTACTS CLOSE WHEN SWITCH DEPRESSED). LOCK SWITCH (NORMALLY OPEN) + TO J7 / OUT 2 TO J7 / OUT 4 TO AUX POWER (TERMINAL 6) ZONE ZONE TO ZONE 7 (+) (TERMINAL 20) YELLOWWHITE GREEN (READY) RED (ARMED) REDBLACK 820 ohms 820 ohms J7_keyswitch Figure 3-25: Remote Keyswitch Wiring Smoke Detector Reset Output 1 may be used to reset 4-wire smoke detectors. Use this output to trigger a low current relay, and wire the power for the smoke detectors through the relay’s contacts. NOTE: The output is normally high (12VDC) and goes low when the User Code + Off is entered at the keypad. To install a relay for smoke detector reset, perform the following steps: Step Action 1 Connect power terminals of the relay to the panel’s auxiliary power (terminals 6 & 7). 2 Connect trigger input of the relay to Output 1 on J7. 3 Connect the “pole” (common) of the relay to terminal 6 of the control. 4 Connect the positive side of the smoke detectors to the normally closed contact of the relay. 5 Connect the negative side of the smoke detectors to terminal 7 of the control. Remote Keypad Sounder This feature is available in the VISTA-128BP only. An optional Amseco PAL 328N Piezo Sounder can be used to duplicate the sounds produced by the keypad's built-in sounder. The panel will remote all sounds (e.g., alarm, trouble, chime, entry/exit, etc.) produced by the keypad's built-in sounder except for the short beeps associated with keypad key depression. One application of this feature might be to produce chime sounds at a distant location from the panel's keypads. Remote Keypad Sounder Setup To setup for a remote keypad sounder, connect the piezo sounder to the panel’s positive auxiliary power output and to Output 1 on the J7 connector as shown in Figure 3-26. To duplicate the keypad sounds for a particular partition, program that partition number in field ✳15. Program field 1✳46 Auxiliary Output Enable with a [2]. 1 2 3 4 5 6 7 8 9 GRAY (GROUND) YELLOW (OUT 1) WHITE (GROUND) RED (OUT 2) GREEN (GROUND) BROWN (OUT 3) BLUE (GROUND) BLACK (OUT 4) J7 CONNECTOR IF USED. 1. OUT 1 IS NO LONGER USABLE FOR SMOKE DETECTOR RESET OR GROUND START (SEE FIELD 1*46). 2. OUT 2 & 4 CAN NO LONGER BE USED TO PROVIDE ALARM TRIGGERS. N/U 4142TR CABLE BLACK – AMSECO PAL-328NPIEZO SOUNDER + REDTO AUX POWER + TERMINAL 6 10mA CURRENT DRAIN) J7_trigcon-001-V1 Figure 3-26: Remote Keypad Sounder Wiring Section 3 - Installing the Control 3-20 Installing the VA8200 Panel Link Module The VA8200 Panel Link Module (PLM) connects to the keypad (ECP) terminals on the VISTA-128BP/VISTA- 250BP and also connects to other PLMs via the RS-485 bus (3-wire twisted cable run). Figure 3-27 is a block diagram of a panel linking setup using three control panels. UL Panel Linking is not permitted in UL installations. CONTROLPANEL CONSOLEPLM CONTROLPANEL CONSOLE PLM CONTROLPANEL CONSOLE PLM EC P EC P EC P RS-485 PLG-001-V0 Figure 3-27: Panel Linking Block Diagram ECP Wire Run Limitations Determine wire gauge by referring to the table below. Wire Run Length Table Wire Gauge Length #22 gauge 450 feet #20 gauge 700 feet #18 gauge 1100 feet #16 gauge 1750 feet • The length of the ECP wire runs combined must not exceed 2000 feet when unshielded cable is used (1000 feet if unshielded cable is run in conduit or if shielded cable is used). • If more than one ECP device is wired to a single run, then the above maximum lengths must be divided by the number of devices on the run (e.g., the maximum length is 225 feet if two keypads are wired on a #22 gauge run). RS-485 Bus Wire Run Limitations The RS-485 bus from the first Panel Linking Module to the last Panel Linking Module cannot exceed 4000 feet, using 16-AWG twisted-pair cable. The recommended form of wiring is to daisy chain the connection from one unit to another. If several buildings are to be connected, the RS-485 bus should form a continuous path from one building to the next. Avoid wiring units in a star configuration, where multiple branches are formed. Star configurations create loading and capacitance problems that are complex, and become difficult to troubleshoot. Mounting and Wiring the Panel Link Module • The PLM will not operate until the device is enabled in the control’s Device Programming in #93 Menu Mode. • Do not mount the PLM on the cabinet door or attempt to attach it to the PC board. To mount and wire the Panel Link Module, refer to Figure 3-28 and perform the following steps: Step Action 1 Remove all power from the control panel before making any wiring connections. 2 Mount the module in the control cabinet if space is available or, adjacent to the cabinet, using 2-faced adhesive tape. 3 Set the PLM’s DIP switches for a device address between 01 and 30. See the module’s instructions for the DIP switch table. Do not use an address being used by another device (keypads, RF receivers, etc.). 4 Connect the 12V (+) and (–) and data-out and data-in connections from the PLM to the control’s keypads terminals (6, 7, 8, and 9), respectively. 5 Connect the 3-wire RS-485 cable between each PLM. Recommended wiring is to bring the wires “in” from one module (or control panel) to terminals 5 (+), 6 (-), and 7 (G) and “out” to the next module from terminals TB1-8 (+), 9 (-), and 10 (G). +_ G +_ G + _ 1 2 3 4 5 6 7 8 PLG-002-V0 RS-485 RS-485 EOL JUMPER PINS PIEZO SOUNDER TAMPER REED SWITCH DIP SWITCH ECP IN ECP OUT Figure 3-28: VA8200 Panel Link Module Wiring VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-22 Long Range Radio Connected to the J7 Triggers These triggers may be used to trip auxiliary alarm signaling equipment such as ADEMCO’s 7720, 7720ULF, and 7920SE Long Range Radios. The triggers are common to all partitions and must be enabled for each partition (field 2✳20). The fire and burglary/audible panic alarm triggers are normally LOW and go HIGH until a User Code + OFF is entered in all enabled partition(s) that display these conditions. The silent panic/duress trigger latches HIGH, except for duress, which is momentary. Refer to the installation instructions that accompany your radio for the connections to the control panel. Long Range Radio Connected to the ECP The control can support an ECP Long Range Radio (LRR) (7820, 7835C, 7845C and 7845i are supported) that connects to control panel’s keypad terminals. All messages programmed for transmission via the phone lines may also be sent via the LRR. These messages are transmitted in Contact ID format regardless of the format programmed for the control in fields 45 and 47. We recommend that, if possible, you use Contact ID for the main dialer. If Contact ID is not used, certain types of reports are not sent. Operation The VISTA-128BP/VISTA-250BP features Dynamic Signaling Delay and Dynamic Signaling Priority message reporting when Long Range Radio is used. These options are accessed through data fields ✱56 and ✱57, respectively. The Dynamic Signaling feature is designed to reduce the number of redundant reports sent to the central station. The feature is described as follows: Dynamic Signaling Delay (Field ✱56) Select the time the panel should wait for acknowledgment from the first reporting destination before it attempts to send a report to the second destination. Delays can be selected from 0 to 225 seconds, in 15-second increments. Dynamic Signaling Priority (Field ✱57) Select the initial reporting destination for reports, Primary Dialer (0) or Long Range Radio (1). The chart below provides an explanation of how the Dynamic Signaling feature functions. If Priority (✱57) is… And message is… Then… Acknowledged before delay expires Report is removed from queue and no message is sent to LRR. Primary Phone No. ("0") Not acknowledged before delay expires Report is sent to both the Primary Phone No. and LRR. Long Range Radio ("1") Acknowledged before delay expires Report is removed from queue and no message is sent to Primary Phone No. Not acknowledged before delay expires Report is sent to both the Primary Phone No. and LRR. Additional LRR reporting options are defined by selecting the events for each subscriber ID in fields 58 and 59. The reporting events are Alarms, Troubles, Bypasses, Openings/Closing, System Events, and Test. Also, within an enabled category, the specific event must be enabled for dialer reporting. If, for instance, zone 10 is enabled to report, but zone 11 is not, zone 10 will report via the LRR, but Zone 11 will not. Reports are transmitted from the VISTA- 128BP/VISTA-250BP to the LRR on a “first in/first out” basis. If events occur at the same time, they are transmitted in order of priority. The priority from most to least important is : Fire Alarms, Panic Alarms, Burglary Alarms, Fire Troubles, Non-Fire Troubles, Bypasses, Openings/Closings, Test messages, and all other types of reports. There are two subscriber IDs programmed into the LRR: primary and secondary. These correspond to the two subscriber ID’s programmed into the control for each partition. If a subscriber ID for a partition is not programmed (disabling reports to that central station), the events enabled for the corresponding subscriber ID in the LRR will not be transmitted. If the event is to be reported to both phone numbers (dual reporting), then reporting through the LRR will be done in an alternating sequence. The first event in the queue is transmitted to both the primary and the secondary radio central stations before transmitting the second event. If split reporting is selected for the VISTA- 128BP/VISTA-250BP, then the LRR will send the appropriate reports to the primary and secondary central stations. Installing the ECP LRR To install the ECP LRR, perform the following steps: Step Action 1 Mount the radio according to the instructions that accompany the radio. Section 3 - Installing the Control 3-23 2 Connect the data in/out terminals and voltage input terminals of the radio to the control’s keypad connection points, terminals 6, 7, 8, and 9. See Figure 3-29. RED BLACK GREEN YELLOW CONTROL TERMINALS 7 8 9 6 ECP RADIO Figure 3-29: Wiring Long Range Radio to Keypad Terminals Supervision The data lines between the control and the LRR, as well as certain functions in the radio, can be supervised. If communication is lost or a trouble condition occurs, both the LRR and the control’s dialer can be programmed to send a Trouble message to the central station. NOTE: For complete information, see the Installation Instructions that accompany the radio. Trouble Messages The following messages are displayed on the 6139/6160 when a problem exists on the Long Range Radio: 1. “LRR Battery”: The battery connected to the radio is low. 2. “PLL out of Lock”: The radio has an internal fault and cannot transmit any messages. 3. “Early Power Detect”: RF power is detected without a valid transmission. 4. “Power Unattained”: Full RF power was never attained. 5. “Frwd. Power Loss”: RF power was not sustained throughout the transmission. 6. “Antenna Fault”: A problem with the antenna has been detected. 7. “LRR CRC is bad”: The radio’s EEPROM is corrupt (the internal CRC is bad). NOTES: Items 2 and 3 require factory service. Items 4 and 5 could be the result of a bad or low battery. If the item 6 message appears, check the antenna, connection and cable; if they are secure, factory service is required. All these messages are displayed in conjunction with the “CHECK 8xx” message, which indicates a trouble on the address to which the LRR unit is programmed in the control. All of these events except Antenna Fault are sent to the event log and reported to the central station using Contact ID Event Code 333 (expansion device trouble). Antenna Fault uses Event Code 357. If the tamper is tripped on the LRR, it uses Event Code 341 (expansion device tamper). Installing the Alpha Pager Module The VA8201 Alpha Pager Module (APM) is used for the transmission of alphanumeric messages to a user- subscribed Paging Service. The APM can be programmed to send the information to up to 8 different paging services. In addition, the module can direct the event log reports to a parallel or serial printer and can interface the control to a computer equipped with Home Automation software. UL The Alpha Pager Module is not permitted in UL installations. The types of events (messages) the pager can transmit are divided into 5 categories: alarms, troubles, bypasses, openings/closings, and system. The options for each paging service are: • Paging service phone number • Format (numeric, alphanumeric) • Two Delay Times (numeric format only): the time between dialing and transmitting of pager ID and the time between pager ID and event information • Pager ID number (if necessary) • Partition(s) (which partitions the events are transmitted for) • Types of messages (events) sent. Must be programmed for the pager to work. The APM hangs up between each message. Multiple messages are sent in the order received. If the APM cannot make contact with the paging service, it retries up to 10 times. • The APM is only required for alphanumeric format. The system sends numeric format messages directly. • When using the APM, field ✳14 must be programmed for RS232 input (1). Zone 9 can longer be used as a protection zone. • The APM transmits alphanumeric messages using the TAP protocol. You must check with the paging service to ensure that they are using the TAP protocol Rev. 1.8 or higher. VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-24 Paging Service Advisory If you are setting up the software for the first time, contact your paging service provider for the following two pieces of information: • The exact access number to be used with each receiving device • The correct PIN number for each receiving device. Pager Formats The system supports pager formats numeric and alphanumeric. Numeric Format SSSS P EEE ZZ, where: SSSS The partition’s 4-digit subscriber number (field ✳32) P Partition number EEE 3-digit event code ZZZ 3-digit zone or user number NOTE: If any of the digits for the subscriber number are hex digits (A, B, C, D, E, F), they will be replaced with 0, 1, 2, 3, 4, 5, respectively, on the pager display. Numeric Format Event Codes Event Code Alarm 333 Trouble 555 Open 444 Close 777 Other 000 Alphanumeric PP Date Time EA ZZZ SSSS AD Where: PP Partition number (e.g., P1) Date Date the event occurred (e.g., 03/15/00) Time Time the event occurred (e.g., 01:16AM) EA Event alpha descriptor (see APPENDIX D) ZZZ Zone or user number SSSS The partition’s 4-digit subscriber number (in field ✳32) AD The zone’s programmed alpha descriptor ✳ ✳ If the event is an arming or disarming, a 6- character descriptor can be sent for the user, if programmed, instead of the user number. The descriptor can be programmed only via the Compass Downloader. The installer code has a default of INSTLR and user number 002 has a default of MASTER for the 6-character descriptor. Mounting the Alpha Pager Module The Alpha Pager Module (APM) may be mounted in the control cabinet if space is available or, if this is not possible, on the side of the cabinet or adjacent to it. Do not mount the Alpha Pager Module on the cabinet door or attempt to attach it to the PC board. To mount the Alpha Pager Module, perform the following steps: Step Action 1 If you are mounting the Alpha Pager Module inside the control cabinet, attach it to the cabinet’s interior surface with 2-faced adhesive tape. 2 If you are mounting the Alpha Pager Module outside the cabinet, use the bracket interface (Ademco Part Number K5350). Wiring the Alpha Pager Module The Alpha Pager Module connects via the 4142TR cable to the J8 connector on the VISTA-128BP/VISTA- 250BP. To wire the Alpha Pager Module, refer to Figure 3-30 and perform the following steps: Step Action 1 Connect the 4142TR to J8 on the control. 2 Connect the Brown wire of 4142TR to the Orange wire of the APM. 3 Connect the Green wire of the APM to TB1- 23 of the control panel. 4 Connect the Red and Black wires of the APM to terminals 6 and 7 (auxiliary power (+) and (-), respectively) of the control. 5 Connect the APM RJ11 connector labeled LINE to the handset terminals on the control panel (terminals 26 and 27). 6 Connect the handset side of telephone line to APM RJ11 connector labeled PHONE (Optional) (Brown and Gray wires of Phone Cord). 7 If you are using a parallel or serial printer, connect the printer according to the instructions accompanying the APM. • The serial printer must be configured for a baud rate of 1200, eight data bits, no parity, and one stop bit. (8/N/1). • The serial printer and Home Automation cannot be used on the same system. If you want to use a printer and Home Automation, you must use a parallel printer. Section 3 - Installing the Control 3-25 VA8201 ALPHA PAGER MODULE AUX PWR. PARALLEL PRINTER PARALLEL OUTPUT SERIAL OUTPUT DATA/ POWER TO PHONE TO LINE EARTH GROUND HOME AUTOMATION COMPUTER TIP RI N G RJ31X JACK TIP RING INCOMING TELCO LINE ANSWERING MACHINE CALLER ID UNIT PREMISES CALLER ID UNIT, ANSWERING MACHINE, AND PHONES RE D BROWN GRAY GR E E N RED BLACK GREEN RED BLACK GREEN AUX GND. 62627282930237 TIP RING HANDSET TIP RING INCOMING PHONE CORD (ZONE 9)BROWN WIRE FROM 4142 TR TRIGGER CABLE SPLICE VA8201-SOC-V1 1 2 3 4 5 6 7 8 9 J8 BR O W N ORANGE CONTROL PANEL NOTE WHEN USING THE VA8201, ZONE 9 CAN NO LONGER BE USED AS A PROTECTION ZONE. Figure 3-30: Wiring the Alpha Pager Module Access Control Using VistaKey The VistaKey is a single-door access control module that, when connected to the alarm system, provides access control to the protected premises. The VISTA- 128BP supports up to 8 modules, the VISTA-250BP supports up to 15 VistaKey modules (15 access points). DO NOT USE BOTH the VistaKey and a PassPoint Access Control System on the same alarm panel. UL The VistaKey module contains three zones. These zones should ONLY be used for access control functions in UL installations. THESE INPUT ZONES ARE NOT TO BE USED FOR FIRE AND BURGLARY APPLICATIONS IN UL INSTALLATIONS. VistaKey Features • Each VistaKey communicates with the VISTA- 128BP/VISTA-250BP via the V-Plex polling loop. • In the event local power to the VistaKey is lost, the VistaKey module provides backup monitoring of the access point door via a built-in V-Plex device that is powered solely from the polling loop. It is programmed as a new type of V-Plex device as part of the control’s V-Plex Device Programming. A serial number label is affixed to the VistaKey module for manual entry of its serial number. • The VistaKey supports up to 500 cardholders. • The addition and removal of VistaKey modules from the system is easily accomplished via the VISTA-128BP/VISTA-250BP keypad. • All configurable options for each VistaKey are accomplished via software, firmware, and nonvolatile memory, eliminating the need for PC board jumpers. The access point zone number (1- 15) is set via a user-friendly, 16-position rotary switch. • Each VistaKey provides one open-collector output trigger (sink 12mA @ 12VDC). Mounting and Wiring the VistaKey For detailed instructions on how to install and program the VistaKey, refer the Installation and Setup Guide that accompanies the VistaKey- SK. To mount and wire the VistaKey module, perform the following steps: Step Action 1 Mount the VistaKey, door strike or mag lock, and card reader. 2 Mount the door status monitor (DSM) and/or request-to-exit (RTE) devices. 3 Using Figure 3-31 as a reference, connect the card reader interface cable to TB3, making the +5V or +12V connection last. VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-26 Step Action 4 Connect the leads to TB1 in the following order: a. All ground leads to terminals 2, 5, and 9. b. The DSM, (optional) RTE, and General Purpose leads to terminals 6, 7, and 8, respectively. c. Door strike (or mag lock) lead to terminal 10. d. Local +12V or +24V supply lead to terminal 1. e. Local +12V or +24V supply lead to the N/C relay terminal 11 (if a mag lock is being used), OR to the N/O relay terminal 10 (if a door strike is being used). 5 Connect the (–) polling loop and (+) polling loop leads (from the VISTA-128BP/VISTA- 250BP) to terminals 4 and 3, respectively. 6 Set the Address Select switch to the desired access door number (1-15). 7 Repeat steps 1 through 6 for each VistaKey being installed. Connecting the Card Reader Lead from Reader Lead Color To VistaKey TB3 Terminal # Green LED Orange 1 Ground* Black 2 DATA 1 (Clock) White 3 DATA 0 (Data) Green 4 +5VDC† Red† 6 +12VDC† Red† 7 * TB-3 Terminal 5 is also a ground and may be used instead of terminal 2. Terminals 2 and 5 are a common ground. † Connect to +5VDC OR +12VDC per reader manufacturer’s specification. +WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM. POLE Door Strike/Mag Coil DATA 1 (WHITE) DATA 0 (GREEN) NOTE 1: USE UL LISTED ENERGY CABLE FOR ALL CONNECTIONS. NOTE 2: VISTAKEY TB3 TERMINAL 5 IS A GROUND AND MAY BE USED INSTEAD OF TB3 TERMINAL 2. TB3 TERMINALS 2 AND 5 ARE A COMMON GROUND. NOTE 3: WHEN USING TRIGGER TO TURN ON AN LED OR BUZZER, RETURN HIGH SIDE OF LED OR BUZZER TO TB3 TERMINAL 7. TRIGGER RATING IS 15mA AT 12VDC. +5V GND TRIGGER (SEE NOTE 3) +12V (RED) ZONE C (General) ZONE A (DSM) ZONE B (RTE) POLLING LOOP - 14V MAX (12V @ 85-160mA Nominal) POLLING LOOP + GND GND GND N/O DOOR STRIKE POWER N/C MAG COIL POWER 2 3 4 5 6 7 8 111223456789101 RELAY CONTACT RATINGS: 3A @ 28VDC MAX. (RESISTIVE LOAD)TB 1 TB 3 1 READER INTERFACE CABLE GND (BLACK) RDR LED (ORANGE) TO ALARM SYSTEM CONTROL PANEL POLLING LOOP TERMINALS. NO CONNECTION VISTAKEY THIS DEVICE COMPLIES WITH PART 15 CLASS A LIMITS OF FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) IT MAY NOT CAUSE HARMFUL INTERFERENCE. (2) IT MUST ACCEPT ANY INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. K1 DOOR CONTROL RELAY FOR ADDITIONAL RATINGS AND SPECIFICATIONS, REFER TO INSTALLATION INSTRUCTION FOR THE VISTAKEY-SK. THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION'S STANDARDS 70 & 74 (NATIONAL FIRE PROTECTION ASSOC., BATTERYMARCH PARK, QUINCY, MA. 02269). PRINTED INFORMATION DESCRIBING PROPER MAINTENANCE, EVACUATION PLANNING AND REPAIR SERVICE IS TO BE PROVIDED WITH THIS EQUIPMENT. TO T B 1 , 1 1 O R 1 2 + 12 VDC TO ONLY ONE OF THESE INPUTS. (FROM TB1-1) Figure 3-31: Wiring the VistaKey Access Control Using the PassPoint Access Control System The VISTA-128BP/VISTA-250BP interfaces with the PassPoint ACS via the VISTA Gateway Module (VGM). The VGM is connected between the ECP bus (keypad terminals) of the control and the network bus of the PassPoint ACS. The control sends the VGM its status information, event log entries, and entry/exit requests (inputs programmed with response type Access Point) from keypads, hardwired zones, and RF transmitters. Section 3 - Installing the Control 3-27 The VGM then reformats and retransmits this information to the Main Logic Board, (MLB) on the PassPoint ACS network bus. UL Interfacing the VISTA-128BP/VISTA-250BP with the PassPoint Access Control System via the VISTA Gateway Module is not permissible for UL installations. Wiring the VISTA Gateway Module The VISTA Gateway Module is connected between the ECP bus (VISTA-128BP/VISTA-250BP keypad terminals) and the network bus of the PassPoint Access Control System. See Figure 3-32 for the proper wiring connections. }ECHELON NETWORK (PASSPOINT ACS) YELLOW RED BLACK PROM C TRANSFORMER 4-PIN KEYPAD PLUG }TO CONTROL’S KEYPAD TERMINALS GREEN Figure 3-32: Wiring the VISTA Gateway Module Installing a 4100SM The 4100SM is used to print event log reports to a serial printer or to interface the control with a computer equipped with Home Automation software. When using the 4100SM, the system can interface with either a serial printer or Home Automation. It cannot do both. NOTE: See SECTION 4: Programming for the programming details when using the 4100SM. Printer/Computer Configurations Configure the serial printer or the Home Automation computer as follows: • 8 data bits, no parity, 1 stop bit • 1200 baud Connecting the 4100SM to a Serial Printer To connect a serial printer using the 4100SM, refer to Figure 3-33and perform the following steps: Step Action 1 Connect terminal 1 on the 4100SM to the Violet wire on the 4142TR cable. 2 Connect terminal 6 on the 4100SM to the Brown wire on the 4142TR cable. 3 Connect the 4142TR cable to J8 on the control. 4 Connect terminals 8 and 7 of the 4100SM to terminals 6 and 7 (aux. power (+) and (-)), respectively of the control. 5 Connect the UL EDP Listed serial printer to the 4100SM Interface Module. The 4100SM Module is supplied with a 10- foot RS232 cable. A longer cable can be used if the VISTA-128BP/VISTA-250BP is separated from the serial printer by more than 10 feet, but the total cable length should be less than 50 feet. 123456789 NU J8 CONNECTOR VIO L E T GR E Y YE L L O W RE D GR E E N BR O W N BL U E BL A C K IN 2 IN 3 GROUND OUT 5 OUT 6 GROUND GROUND PRI N T E R D T R 4142TR CABLE (SUPPLIED WITH 4100SM) 8 7 6 5 4 3 2 1 4100SM SERIAL MODULE + PWR - (GND) RXD not used not used TXD not used DTR BLUE WHITE To TB6 Aux. Power (+) (25mA current draw) To TB7 Aux. Power (-) USE GENDER CHANGER SUPPLIED WITH 4100SM IF PRINTER HAS DB25 MALE CONNECTOR 3MCableSupplied with 4100SM SERIAL PRINTER SET FOR: 8 DATA BITS EVEN PARITY STOP BIT300/1200 BAUD 4100SM JUMPERS (CUT TO SET RESPECTIVE SIGNAL FLOATING) COLORFUNCTIONPIN # RED BLUE WHITE CD CTS DSR 8 5 6 RED 41 0 0 S M - 0 1 1 - V 0 Figure 3-33: 4100SM Using a Serial Printer NOTE: See the 4100SM Installation Instructions for details concerning the serial printer operation. Connecting the 4100SM to a Home Automation Computer To connect the computer to the 4100SM, refer to Figure 3-34 and perform the following steps: Step Action 1 Connect terminal 23 on the control panel to terminal 3 on the 4100SM. 2 Connect terminal 6 on the 4100SM to the Brown wire on the 4142TR cable. 3 Connect the 4142TR cable to J8 on the control. 4 Connect terminals 8 and 7 of the 4100SM to terminals 6 and 7 (aux. power (+) and (-)), respectively of the control. 5 Connect the Home Automation computer VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-28 serial port to the 4100SM Interface Module. 123456789 NU J8 CONNECTOR VIO L E T GR E Y YE L L O W RE D GR E E N BR O W N BL U E BL A C K IN 2 IN 3 GROUND OUT 5 OUT 6 GROUND GROUND PRINTER DTR 4142TR CABLE (SUPPLIED WITH 4100SM) 8 7 6 5 4 3 2 1 4100SM SERIAL MODULE + PWR - (GND) RXD not used not used TXD not used DTR BLUE WHITE To TB6 Aux. Power (+) (25mA current draw) To Serial Port of Computer To Terminal TB23 (Zone 9 [+]) To TB7 Aux. Power (-) RED 4100SM-013-V0 Figure 3-34: 4100SM Using Home Automation NOTE: See the Home Automation software instructions for details concerning its operation. Installing the 4285/4286 VIP Module The 4285/4286 VIP Module is an add-on accessory that permits the user to access the security system (and relays) via a TouchTone telephone. This may be done either from the premises or by calling the premises from a remote location. Only one VIP Module can be used in a security system. This module must be enabled as Device Address 4 in the Device Programming in #93 Menu Mode, and must be assigned to a partition. UL The 4285/4286 VIP Module is not permitted in UL installations. Detailed operating instructions for phone access to the security system are provided with the VIP Module. The 4285/4286 VIP Module features: • Allows the user to receive synthesized voice messages over the phone regarding the status of the security system. • Allows the user to arm and disarm the security system and perform most other commands using the telephone keypad. • Allows the user to control relays using the telephone keypad. • Provides voice annunciation over the phone to confirm any command that is entered. • Announces many of the same words that would normally be displayed on an alpha keypad under the same system conditions. Refer to the words in bold on the Alpha Vocabulary list found in the #93 Menu Mode in the Programming Guide. • Can be supervised for connection to control panel (annunciated and reported as Zone 804). The 4285/4286 is wired between the control panel and the premises’ handset(s) (see Figure 3-35). It listens for TouchTones on the phone line and reports them to the control panel. During on-premises phone access, it powers the premises phones. During off-premises phone access, it seizes the line from the premises phones and any answering machines. • The VIP module will not operate until the device address (04) is enabled in the control’s Device Programming in #93 Menu Mode. • Do not mount the VIP Module on the cabinet door or attempt to attach it to the PC board. To install the VIP module, perform the following steps: Step Action 1 Mount the module in the control cabinet if space is available or, if this is not possible, on the side of the cabinet or adjacent to it. If you mount the VIP Module inside the control cabinet, attach it to the cabinet’s interior surface with 2-faced adhesive tape. You may leave the module’s cover off if it is mounted within the cabinet. If you mount the module outside the cabinet, use the screw holes at the rear to mount horizontally or vertically (2-faced adhesive tape may be used, if preferred). 2 Affix the 4285/4286 connections label (supplied separately) to the inside of the VIP Module’s cover, if the cover is used. Otherwise, affix the label to the inside of the Section 3 - Installing the Control 3-29 control cabinet’s door. 3 Make 12V (+) and (–) and data-in and data- out connections from the VIP Module to the control, using the connector cable supplied with the VIP Module. These are the same connections as for remote keypads. Step Action Connect the module to the phone line as shown below. See Figure 3-35. 4285/4286 Terminal Connects to direct connect cord: 1. Phone In (Tip) green wire 2. Phone In (Ring) red wire 3. Phone Out (Tip) brown wire 4. Phone Out (Ring) gray wire 5. No Connection 6. Audio Out 1∗ Speaker 7. Audio Out 1∗ Speaker 4 ∗∗∗∗Supported by the 4286 only Use an RJ31X Jack with the phone cable supplied with the control to make connections to the VIP module. Make connections exactly as shown in Figure 3-35. This is essential, even if the system is not connected to a central station. The 4285/4286 will not function if this is not done. • If touch-tones are not present following phone access to the security system via an on-premises phone, try reversing the pair of wires connected to terminals 3 and 4 on the 4285/4286. • If the phone plug is disconnected from the control, the premise’s phones will not operate. YELLOW NOCONNECTION RED BLACK GREEN TO CONTROL PANEL KEYPAD CONNECTIONS KEYED HEADER 12 3 4 5 6 7 NO CONNECTION 4286 VIP MODULE ANSWERING MACHINE PREMISES ANSWERING MACHINE AND PHONES TI P RI N G RJ31X JACK TIP RING INCOMING TELCO LINE CALLER ID UNIT IMPORTANT NOTE FOR EXISTING INSTALLATIONS: EXISTING WIRES CONNECTED TO THE “HANDSET” TERMINALS ON CONTROL MUST BE MOVED FROM THERE TO TERMINALS 3 AND 4 ON THE 4286. U.S.PATENT No.4791658 THIS DEVICE COMPLIES WITH FCC RULES, PART 68 FCC REGISTRATION No.AC3USA-74659-KX-N RINGER EQUIVALENCE:1.0B FOR COMPLETE INFORMATION, SEE INSTALLATION INSTRUCTIONS N6431-3 ACCOMPANYING 4286 VIP MODULE GREY BROWN GR E E N RE D EARTH GROUND TIP RING TIP RING 4500 THERMOSTAT GREENYELLOW HANDSETINCOMING TELCO LINE NOTE: 4286 DEVICE ADDRESS IS FACTORY SET TO “4” SEE SPEAKER NOTE SPEAKER NOTE:IF CONNECTING SINGLE SPEAKER, USE 8-ohm SPEAKER ONLY. IF CONNECTING 2 SPEAKERS, USE 4-ohm or 8-ohm SPEAKERS AND CONNECT IN SERIES. SPEAKER VOLUME CONTROL 4286_wiring-002-V1 Figure 3-35: VIP Module Connections VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-30 Installing the Audio Alarm Verification Module UL Audio Alarm Verification (AAV) is not permitted in UL installations. • 685 Receiver software must be rev. 4.6 or higher. Earlier versions will not hold the phone line connection. • Contact ID code for “Listen-in to Follow” is 606. Contact ID is the only reporting format that will send a “Listen-in to Follow.” • If you are also using a 4285/4286 VIP Module, be sure to follow Figure 3-37 when making connections. The UVS consists of a UVCM and at least one UVST. The UVCM board has a DC power jack and a 34- position terminal block for making connections to a DC power source, UVSTs, telephone lines, music source, or to the 4286 VIP Module; and to a control panel’s voice trigger and bell outputs (if required). Refer Figure 3- 28 for wiring connections. For a detailed explanation of the wiring connections and the functions of the DC power jack and terminal block positions, refer to the installation instructions that accompany the UVS. If the phone plug is disconnected from the control, the premise’s phones will not operate. NOTES: • When the AAV indicates that the audio alarm verification session is completed, all keypad sounds are restored. Sirens are restored if the alarm timeout period has not expired. • As part of its fail-safe software, the control limits all audio alarm verification sessions to 15 minutes. This is because once the session begins, the AAV Module controls the duration. • If a new Fire alarm should occur during a session, the control breaks the phone connection and sends the new Fire Alarm report, then re- triggers the AAV Mode. All other dialer messages triggered during ongoing conversation are held until either the AAV Module signals that it is inactive, or the 15-minute timeout occurs. Section 3 - Installing the Control 3-31 RE D GR E E N RIN G TIPNO T U S E D EA R T H G N D GN D AU X I L I A R Y A U D E N A B L E AU X I L I A R Y A U D I N SP K R 7 SP K R 6 SP K R 5 SP K R 4 SP K R 3 SP K R 2 SP K R 1 GN D GN D +1 2 V D C I N GN D IN S I D E U V S T P W R IN S I D E U V S T P W R OU T S I D E U V S T P W R AL A R M T R I G I N VO I C E R E L A Y P O L E VO I C E R E L A Y N C FA L L I N G V O I C E T R I G RIS I N G V O I C E T R I G NO T U S E D MIC 7 MIC 6 MIC 5 MIC 4 MIC 3 MIC 2 MIC 1 SWITCH BANK 1 SWITCH BANK 2 SWSWITCH BANK 1 1UVST 1 AUX AUDIO, ON = ENABLED 2UVST 2 AUX AUDIO, ON = ENABLED 3UVST 3 AUX AUDIO, ON = ENABLED 4UVST 4 AUX AUDIO, ON = ENABLED 5UVST 5 AUX AUDIO, ON = ENABLED 6UVST 6, ON = OUTSIDE, OFF = INSIDE 7UVST 7, ON = OUTSIDE, OFF = INSIDE 8VOICE TRIGGER, ON = IMMED, OFF = CALLBACK SWSWITCH BANK 2 1FUTURE USE, SET TO ON 2FUTURE USE, SET TO ON 3TELEPHONE RING, ON = ENABLED 4END USER VOICE, ON = DISABLED 5FUTURE USE, SET TO ON 6CS CODE LEARN, ON = DISABLED 7USER CODE LEARN, ON = DISABLED 8FUTURE USE, SET TO ON SHIPPED WITH ALL SWITCHES IN "ON" POSITION. ON ON AUXILIARY AUDIO LEVEL ADJUSTMENT TRIM POT INCOMING RING INCOMING TIP HANDSET RING HANDSET TIP CONTROL PANEL BE L L O U T P U T GN D AU X P W R ( 1 2 V D C ) 2- W A Y V O I C E T R I G G E R (S E E N O T E 3 ) (O P T I O N A L ; N O T E 5 ) (N O T E 2 ) (N O T E 2 ) 4286 VIP MODULE 12 3 4 5 6 7 12 3 4 KEYED HEADER SPEAKER VOLUMECONTROL OPTIONAL (NOTE 4) UV S T P W R GN D MIC SP K R SPEAKER VOLUME TRIM POT TYPICAL 1 OF 7 AUDIO OUT GND MUSIC SOURCE OPTIONAL (NOTE 4) PREMISES ANSWERING MACHINE AND PHONE (S) ANSWERING MACHINE P3 UVST VOLUME CONTROL DIAL TIPRIN G TIP RING 1234567812345678 NOTE 1: CONNECT TO PROPER EARTH GROUND. NOTE 2: POWER MAY ALSO BE SUPPLIED BY A LISTED CLASS 2 POWER SUPPLY RATED 12VDC, MIN 600mA CONNECTED TO THE UVCM +12VDC IN AND GND TERMINALS. NOTE 3: SOME CONTROL PANELS USE BUILT-IN TRIGGER AND SOME USE 4204 RELAY MODULE. REFER TO AAV SECTION OF CONTROL PANEL INSTALLATION AND SETUP GUIDE FOR CONNECTION. NOTE 4: EITHER MUSIC SOURCE OR 4286 VIP MODULE CAN BE USED BUT NOT AT THE SAME TIME. NOTE 5: DO NOT CONNECT IF 4286 VIP MODULE IS USED. 1234567891011121314151617181920212223242526272829 3031323334 SE L E C T AP P R O P R I A T E IN P U T RJ31X JACKPLUG DIRECT CONNECT CORD NOTE 1 UVCM AND UVST SUMMARY OF CONNECTIONS P2 P1 P7 FOR COMPLETE INFORMATION, SEE 4286 VIP MODULE INSTRUCTIONS. WARNING: TO PREVENT RISK OF ELECTRICAL SHOCK, DISCONNECT TELCO JACK BEFORE SERVICING THIS PANEL. COMPLIES WITH FCC RULES, PART 68FCC REGISTRATION NO. AC3 USA-40133-SP-TRINGER EQUIVALENCE: 1.0B THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFULINTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. 1 2 3 4 Refer to UVS Installation and Setup Guide K4214 for complete information GR A Y BR O W N UV C M _ U V S T - S O C - V 1 INCOMINGTELCO LINES ALTERNATE +12 VDC IN FOR PLUG-IN WALL PACK (SEE NOTE 2) Figure 3-36: UVS Connections to the Control Panel Installing TeleSmart The TeleSmart system provides a telephone interface and message center for an ADEMCO security system. It has the following features: • 4 unique mailboxes for storing messages • 6 user access codes • Security system interface • Memo feature for leaving messages for other users • Caller ID capabilities for up to 25 phone numbers • Memory (speed) dialing for up to 15 phone numbers • Repeat dialing (automatically redials busy numbers) • Last number redial • Call screening (with and without Caller ID) • Privacy (turns off the ringer) • Remote access of TeleSmart and security system VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-32 NOTE: The keypad connected to the TeleSmart module must be the 6139T. UL TeleSmart is not permitted in UL installations. Mounting the Telesmart Module The TeleSmart Module should be mounted in the security system’s control cabinet if space is available, or within a grounded metal enclosure to provide proper ESD protection. Mounting Inside the Control’s Cabinet: Use double-sided tape to attach the module to the interior surface of the cabinet, or hang it on two screws. Do not mount it on the cabinet door or attach it to the control’s PC board. Mounting Outside the Cabinet: Use the screw holes at the rear of the module. Wires can be brought out from the side or back (use the round breakout on the back). Affix the Summary of Connections label to the module’s inside cover or to the inside of the cabinet door. Wiring Connections Before making connections, power down the control panel. To wire the TeleSmart, perform the following steps: Step Action 1 Use a standard RJ31X phone jack (CA38A in Canada) and direct-connect cord. Connect the direct-connect cord’s red and green wires to the control’s incoming phone line terminals as described in the control’s instructions. (Figure 3-37) 2 Connect the direct-connect cord’s brown and gray wires to TeleSmart’s “Home Phones” terminals, disconnecting them from the control’s premises phone terminals, if previously connected. 3 Connect the control’s local phone TIP and RING terminals to TeleSmart’s “From Control” terminals (wires not supplied). 4 Connect an 8-Ohm speaker to TeleSmart’s speaker terminals. (Figure 3-38) 5 Disconnect those keypads intended to be used with TeleSmart from the control’s terminals, if previously connected. Step Action Connect keypad wiring as shown in (Figure 3-39) (see the chart below for the maximum wire run length for wire gauge you are using). NOTE: Run audio cable in separate 2- conductor twisted-pair cable (22AWG recommended). This cable should be kept at least 6 inches from other types of cables carrying potentially interfering signals, such as AC power, telephone, and polling loop cables. WIRE RUN LENGTHS Gauge 150mA 300mA 500mA 600mA 750mA 22 AWG 160ft 80ft 50ft 42ft 32ft 20 AWG 260mA 130mA 80mA 67mA 52mA 18 AWG 410mA 220mA 130mA 115mA 83mA 16 AWG 650mA 330mA 200mA 170mA 130mA 6 7 Set the keypad address, tamper option, and playback volume setting by pressing and holding the [1] and [3] keys at the same time for 3 seconds, then follows the prompts. You must press these keys within 60 seconds of power-up to set the address and/or tamper option; you can set the volume at any time after power-up. Refer to the instructions included with the keypad for additional details. You must set TeleSmart keypads to addresses 0-7 only. 8 TeleSmart Plus is powered from the control’s +12VDC keypad terminal. Connect the control’s keypad terminals to the TeleSmart Plus Control terminals as shown. (Figure 3- 41) IMPORTANT: You must program the TeleSmart module as device address 24 when programming the control. 9 This connection is used to drive the TeleSmart internal clock. Connect either terminal of the control’s AC input terminals to the TeleSmart RTC terminal. (Figure 3- 40) 10 Connect the TeleSmart ground terminal to a good earth ground. (Figure 3-40) Section 3 - Installing the Control 3-33 TYPICAL CONTROL’S PHONE TERMINALS LOCAL INCOMING RING TIP RING TIP RED GREEN BROWN GREY DIRECT CONNECT CORD 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 RJ31X 1 2 3 45 6 7 8 RING TIP INCOMING PHONE LINE TO PREMISES PHONES GREENRED GREY BROWN RING TIP FROM CONTROL HOME PHONES phon_conn-V0 Figure 3-37: TeleSmart Phone Connections NOTE: If the system hangs up the phone line when calling in from a remote location, check the phone connection terminals (Term. 17/18 = from control; Term. 15/16 = to house phones). 8 ohm Speaker 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 AUX SPEAKER Figure 3-38: TeleSmart Speaker Connection VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-34 IN OUT GRN (DATA IN) RED (+12VDC) BLACK (–) YEL (DATA OUT) USE OUTER WIRES OF AUDIO CABLE AUDIO IN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 KEYPADS KEYPAD AUDIO BUS ® 1 OFF 4 MAX 7INSTANT READY 2AWAY 5TEST 8CODE 0 3 STAY 6BYPASS 9CHIME # ARMED READY MESSAGE Figure 3-39: Keypad Connections REAL-TIME CLOCK (RTC) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 EARTH GROUND TYPICAL CONTROL'S AC TERMINALS Figure 3-40: RTC and Ground Connections 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 YEL (DATA OUT) RED (+12VDC) GRN (DATA IN) BLACK (-) GND TO CONTROL'S KEYPAD TERMINALS Figure 3-41: TeleSmart to Control Connections Section 3 - Installing the Control 3-35 Connecting the Transformer This product uses the 1361 transformer (1361CN in Canada). If you are using X-10 devices, the 1361X10 transformer interface must be used instead of the regular 1361 transformer. The 1361X10 supplies the control panel with AC, and also sends control pulses through the premises’ electrical system to control the X-10 devices. UL Use 1361CN Transformer in Canadian installations. Power Limiting Outputs All outputs are power-limited as per UL985/UL1023. The following table shows the maximum current that may be drawn from each output. Output Maximum Current Draw Auxiliary Power 750mA Polling Loop 128mA Alarm Output 1.7A For Household Fire or Combination Household Fire/Burglary Installation: The total current drawn from the auxiliary power, the polling loop, and the alarm output combined must not exceed 750mA to comply with the battery independence requirements in UL985. For Household Burglary-Only Installations: The total current drawn from the alarm output may be up to 1.7A. A battery must be installed to supply the current of the combined auxiliary power, polling loop, and alarm output in excess of 750mA. Failure to observe the polling loop current rating will cause polling loop malfunction. Failure to observe the auxiliary power current rating will result in a battery that does not charge properly or possibly a tripped circuit breaker. To connect the transformer to the control, perform the following steps: Step Action 1 Connect all installed devices to the control. 2 Wire the 1361 Transformer (1361CN in Canada) to the panel (before connecting the battery) as shown in Figure 3-42, or wire the 1361X10 Transformer as shown in Figure 3-43 (if using X-10 devices). 3 Plug the transformer into a 24-hour, uninterrupted, 120VAC, 60Hz outlet. After a few seconds, the keypad display appears. NO C O N N E C T I O N TRANSFORMER 16.5VAC, 40VA ADEMCO No.1361 or 1361X10, if X-10 DEVICES WILL BE USED. Connect to24hr. sourceof AC mains 123 RE D ( + ) BL K ( - ) Connect to 12VDC, 4AH or 12VDC, 7AH GEL CELL BATTERY CHARGINGVOLTAGE13.7VDC NOTE: WHEN POWERING UP THE PANEL, PLUG THE TRANSFORMER IN BEFORE CONNECTING THE BATTERY. BATTERYTABSPRIMARY POWER Supplied by a transformer which is rated at 16.5VAC, 40VA. Caution must be taken when wiring this transformer to the panel to guard against blowing the fuse inside the transformer (non-replaceable). pw r _ b a t _ c o n n - 0 0 1 - V 1 Figure 3-42: 1361 Transformer and Battery Connections 123456789 BL A C K BL U E BR O W N GR E E N RE D WH I T E YE L L O W GR A Y VIO L E T 4142TR CABLE X10 TRANSFORMER/INTERFACE TERMINALS ON CONTROL BOARD 1361X10-001-V0 J8 CONNECTOR Figure 3-43: 1361X10 Transformer Connections VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-36 Panel Earth Ground Connections In order for the lightning transient protective devices in this product to be effective, the designated earth ground terminal (terminal 30) must be terminated in a good earth ground. Recommended wire gauge for the ground connection is #16 AWG, run no farther than 30 feet. The following are examples of good earth grounds available at most installations: • Metal Cold Water Pipe: Use a noncorrosive metal strap (copper is recommended) firmly secured to the pipe to which the ground lead is electrically connected and secured. • AC Power Outlet Ground: Available from 3- prong, 120VAC, power outlets only. To test the integrity of the ground terminal, use a three-wire circuit tester with neon lamp indicators, such as the UL-Listed Ideal Model 61-035, or equivalent, available at most electrical supply stores. The panel requires the earth ground connection for its lightning transient protection devices. Determining the Control’s Power Supply Load Use the tables that follow to calculate the total current for the Auxiliary Power, the Alarm Output, and the Polling Loop. In each table, multiply each device’s standby and/or alarm current by the number of units used. 1. In Table 1, enter devices used on the polling loop. Calculate total current draw on the polling loop. Table 1: Total Polling Loop Current Draw Polling Loop Device Current # of Units Total Polling Loop Subtotal (terminals 24 & 25 – 128mA) ✳ ✳ The total current cannot exceed 128mA. If total load exceeds 128mA, then a 4297 Loop Extender Module can be used. Note that the total number of points connected to the panel cannot exceed 119. 2. In Table 2, enter devices used on Auxiliary Power. Calculate standby and alarm currents, then add to get Auxiliary Power current subtotal. Table 2: Auxiliary Power Current Load Total Current Device Model # Device Current X # of Units Standby Alarm Auxiliary Power Subtotal (terminals 6 & 7 – 750mA max.) Section 3 - Installing the Control 3-37 3. In Table 3, enter devices connected to the Alarm Output. Calculate alarm currents, then add to get the Alarm Output current subtotal. Table 3: Alarm Output Current Load Total Current Device Model # Device Current X # of Units Standby Alarm XXXXXX XXXXXX XXXXXX XXXXXX XXXXXX XXXXXX XXXXXX Alarm Output Subtotal (terminals 4 & 5 – 1.7A max.) 4. In Table 4, enter the total calculated subtotals of all listed outputs from Tables 1 through 3, then add to get the combined current. Table 4: Total VISTA-128BP/VISTA-250BP Current Load Total Current Standby Alarm Polling Loop Subtotal (see Table 1) Aux. Power Subtotal (see Table 2) Alarm Output Subtotal (see Table 3) VISTA-128BP/VISTA-250BP PCB Current (Includes 2-wire smoke detector loading on zone 1) 250mA 330mA Total Current Load Determining the Size of the Standby Battery The cabinet supplied with the control panel can house batteries of up to 12V, 14AH (two 12V, 7AH batteries wired in parallel). The VISTA-ULKT kit provides a cabinet that can house batteries of up to 12V, 17.2AH and that may be used with this panel. The total standby current drawn from the auxiliary power and polling loop outputs combined must be limited to 270mA when 14AH batteries are used; and to 390mA when 17.2AH batteries are used. DO NOT use Gates batteries (sealed lead-acid type). These batteries require a different charging voltage than is supplied by the panel. UL Household Fire or Combination Household/Fire/Burglary installations require the use of a backup battery that is capable of providing 24 hours of standby time followed by 4 minutes of alarm time. UL1023 Household Burglary-only installations require the use of a backup battery that is capable of providing 4 hours of standby time followed by 4 minutes of alarm time. Use Table 5 to determine the required backup battery capacity and use Table 6 to determine the battery model number. A dual battery harness is supplied that allows two batteries to be wired in parallel for increased capacity. 5. Using the total calculated from Table 4, calculate the battery capacity required for the installation. Table 5: Battery Capacity Calculation Table Capacity Formula Calculated Value Standby Capacity For 4-hour standby time: Total standby current X 4 hours X 1.4 contingency factor. For 24-hour standby time: Total standby current X 24 hours X 1.1 contingency factor. Alarm Capacity For 4-, 5-, or 15-minute alarm time: Total alarm curr. X 0.067 (4 min) 0.250 (15 min) VISTA-128BP/VISTA-250BP Installation and Setup Guide 3-38 Total Capacity Add standby and alarm capacities 6. Use the Battery Selection Table to select the appropriate battery for the installation. Table 6: Battery Selection Table Capacity Recommended Battery Comment 4AH Yuasa NP4-12 7AH Yuasa NP7-12 12AH Yuasa NP12-12 Fits in large mercantile cabinet only. 14AH Yuasa NP7-12 Connect two in parallel. 17.2AH Yuasa NPG18-12 Fits in large mercantile cabinet only. 7. Connect the battery, referring to Figure 3-42. The standby battery is automatically tested for 10 minutes every 4 hours, beginning 4 hours after exiting Programming mode. In addition, entry into the Test mode initiates a battery test. The VISTA-128BP/VISTA-250BP also runs a 5-second battery test every 60 seconds to check if the battery is connected. 4-1 SECTION 4 Programming •••••••••••••••••••••••••••••••••••••••••••••••• • NOTE: All references in this manual for number of zones, number of user codes, number of access cards, and the event log capacity, use the VISTA-250BP’s features. See SECTION 1: General Description for the table listing the differences between the VISTA-128BP and the VISTA-250BP control panels. Program Modes There are two programming modes for the VISTA- 128BP/VISTA-250BP. These are the Data Field Program Mode and the #93 Menu Mode. The Data Field Program Mode is where many system options are programmed. The #93 Menu Mode is an interactive mode that requires a 2-line alpha keypad (6139/6160). The factory-loaded defaults (✳97) enable keypad addresses 00-01 only. A keypad set to one of these addresses must be used to program the system initially. Local keypad programming can be disabled through Compass downloading software. If this is done, Program mode can only be accessed via the downloading software. Entering and Exiting Programming Mode Enter Programming mode using either method a or b: a. Press both the [✳] and [#] keys at the same time within 30 seconds after power is applied to the control. b. Enter the Installer Code + [8] + [0] + [0] + [0] keys. The factory installer code can be changed once in the Program mode (field ✳00). NOTE: The default for the Installer Code is 4140. Exit the Programming mode by either method a or b: a. Press [✳] + [9] + [8]. Exiting by this method prevents the installer code from being used to re- enter Programming mode. Only method “a” can be used to re-enter Programming mode. b. Press [✳] + [9] + [9]. Exiting by this method permits the installer code to be being used to re- enter Programming mode. Data Field Programming Mode In the Data Field Program Mode you may access any field simply by entering either [✳] or [#] + the field number: • To write or change information in a field press [✳] + the field number (✳03). • To read the information in a field press [#] + the field number (#03). When the entries for a field are completed, the keypad beeps three times and advances to the next field. Summary of Data Field Programming Commands ✳91 Select partition for programming partition-specific fields ✳92 Display the software revision level of the control panel ✳93 Enter Menu mode programming ✳94 Go to next page of fields ✳99 Go back to previous page of fields or exit Programming Mode with no installer code lockout ✳98 Exit Programming Mode with Installer Code lockout Moving Between Programming Levels The data fields are grouped into three levels (referred to as “pages”). The first page is accessed as soon as Programming Mode is entered. The second and third pages of data fields are indicated at the keypad by a 1 and 2, respectively, in front of the 2-digit field address. “ALT PROGRAM MODE” is displayed along with a “100” or “200,” indicating which page of program fields is accessed. To access the next level of programming fields, perform the following steps: Step Action 1 Press ✳94. 2 Press [✴] + [XX], where XX = the last two digits of the program field, and make the desired entry. NOTES: Press ✳94 to move to 2nd page, (fields 1✳01 - 1✳76); press ✳99 to move back to 1st page. VISTA-128BP/VISTA-250BP Installation and Setup Guide 4-2 Press ✳94 to move to 3rd page (fields 2✳00 - 2✳88); press ✳99 to move back to 2nd page Entry Errors • If an address is improperly entered, the keypad displays “FC.” • If a program entry is improperly entered (for example, a larger number than is permitted), the keypad display will go blank. In either of the above cases, simply re-enter [✳] + the correct field number and then enter the correct data. Programming System-Wide Data Fields Values for some programming fields are system-wide (global), and some can be different for each partition (partition-specific). The partition-specific programming fields are automatically skipped when programming the global fields. If the system has only 1 partition, the partition-specific fields are not automatically skipped. To program system-wide data fields, perform the following steps: Step Action 1 Enter Program Mode: Installer Code + 8 0 0 0. The following display appears: Program Mode ✳Fill # View – 00 2 If the control has not been programmed before, enter ✳97 to load factory defaults. 3 Press [✳] and enter the first field number to be programmed (for example, ✳00, Installers Code). Make the desired entry. When the field is complete, the keypad beeps three times and advances to the next field. If you do not want to change the next field, press [✳] and enter the next field number to be programmed. First Page of fields (✳00 - ✳90) To change to the next page of fields, press ✳94. To return to the previous page of fields, press ✳99. 4 Press ✳99 or ✳98 to exit Program Mode. NOTE: If the number of digits that you enter in a data field is fewer than the maximum permitted (for example, a phone number), the keypad displays the last entry and waits. To proceed, enter [✳] + the next data field you wish to program. Programming Partition-Specific Data Fields To program partition-specific data fields once in Program Mode, do the following: Step Action 1 Enter Program Mode: Installer Code + 8 0 0 0. 2 Press ✳91, which will prompt you for the partition number desired. 3 Enter a partition-specific field number (e.g., ✳09) to begin programming. When the first field’s entry is completed, the next partition-specific field is automatically displayed. When all partition-specific fields are programmed, the system returns to the global programming fields (page 1 fields). 4 Repeat this procedure for each partition in the installation. NOTE: To return to the global program fields before finishing all fields, enter any global field number. Programming Partition-Specific Fields Press ✳91 to select a partition. ↓↓↓↓ Enter the partition to be programmed. ↓↓↓↓ Enter a partition-specific field number and make entry. ↓↓↓↓ After partition-specific fields are programmed, press ✳91 to select next partition. Enter any global field number to return to the global fields at any time. #93 Menu Mode Programming The #93 Menu Mode is an interactive mode through which much of the system’s programming is done. In this mode, there are “question and answer” prompts that can be accessed once Data Field Program Mode has been entered. These prompts require a 2-line alpha keypad (6139/6160). After programming all system-related programming fields in the usual way, press #93 while still in VISTA-128BP/VISTA-250BP Installation and Setup Guide 4-2 programming mode to display the first choice of the menu-driven programming functions. Press 0 (NO) or 1 (YES) in response to the displayed menu selection. Pressing 0 will display the next choice in sequence. Below is a list of the main menus. For details refer to the VISTA-128BP/VISTA-250BP Programming Guide. MAIN MENU OPTIONS ZONE PROG? 1 = YES 0 = NO 0 For programming the following: • Zone Number • Zone Response Type • Partition Number for Zone • Dialer report code for zone • Input Device Type for zone (whether RF, polling loop, etc.) • Enrolling serial numbers of 5800 Series transmitters & serial polling loop devices into the system. • Zone Attributes (e.g., Arm w/Fault, Silent, etc.). EXPERT MODE? 1 = YES 0 = NO 0 Same as Zone Programming except: • Done with a minimum number of keystrokes. • Can program wireless keys using pre-defined templates. REPORT CODE PROG? 1 = YES 0 = NO 0 For programming the following: • Alarm report codes for zones • Restore and supervisory codes • All other system report codes ALPHA PROG? 1 = YES 0 = NO 0 For entering alpha descriptors for the following: • Zone Descriptors • Installer’s Message • Custom Words • Partition Descriptors • Relay Descriptors DEVICE PROG? 1 = YES 0 = NO 0 For defining the following device characteristics for addressable devices, including keypads, RF receivers (5881), output relay modules (4204/4204CF), FSA (FSA-8/FSA-24), 4285/4286 VIP Module, Panel Link Module (VA8201), ECP long range radio (7845C), and VISTA Gateway Module: • Device Address • Device Type • Keypad Options (including Partition assignment) • RF House ID • LRR Options (including Programming radio) OUTPUT PGM? 1 = YES 0 = NO 0 For defining output device functions. RLY VOICE DESCR? 1 = YES 0 = NO 0 For entering voice descriptors for relays to be used with the 4285/4286 VIP Module. CUSTOM INDEX ? 1 = YES 0 = NO 0 For creating custom word substitutes for VIP Module annunciation. ACCESS POINT PGM 1 = YES 0 = NO 0 For defining the parameters for each of the VistaKey zones, including which group(s) have access through an access point (door). See the VistaKey-SK Installation and Setup Guide for detailed programming instructions. ACCESS GRP PGM 1 = YES 0 = NO 0 For defining the capabilities (privileges) for each group of users. See the VistaKey-SK Installation and Setup Guide for detailed programming instructions. EVENT/ACTION PGM 1 = YES 0 = NO 0 For defining events and time windows for an access group. See the VistaKey-SK Installation and Setup Guide for detailed programming instructions. SCHEDULED CHK-IN For defining the schedule for the system to automatically call the downloader. VISTA-128BP/VISTA-250BP Installation and Setup Guide 4-4 1 = YES 0 = NO 0 Following is a list of commands used while in the Menu Mode: #93 Menu Mode Programming Commands #93 Enters Menu Mode. [✳] Serves as [ENTER] key. Press to have keypad accept entry. [#] Backs up to previous screen. 0 Press to answer NO. 1 Press to answer YES. 00, or 000+[✳] Quits Menu Mode and goes back to Data Field Programming Mode, if entered at first prompt of each main menu option. Zone Number Designations The VISTA-128BP supports up to 128 zones, the VISTA-250BP supports up to 250 zones, of hardwire, polling loop and/or wireless protection, distributed among up to 8 partitions. The following table lists the zone numbers and the types of sensors that can be used with each, and some alternate functions of the zones. Zone Function 1 2-wire Smoke Detectors (if used) 5 Audio Alarm Verification (if used) 7 Keyswitch (if used) 8 Latching-Type Glassbreak Detectors (if used) 1-9 Traditional Hardwired Zones 9 RS232 Input (if used) 1-250 5800 Series Wireless Devices 10-250 Polling Loop Devices 995 ✳ + 1 Panic 996 # + 3 Panic 999 ✳ + # Panic Zone Defaults Zone # Zone Type Zone # Zone Type 001 09 601-632 00 002 03 800-830 00 003 03 970 00 004** 04 988 00 005 03 990 00 006 03 992* N/A 007 03 995 00 008 03 996 00 009 03 997 05 010–250 00 999 06 NOTES: * Zone 992 is the Duress zone. Programming of the zone response type is not applicable. This zone requires only the report code programming. ** Zone 004 is also defaulted with Auto-STAY enabled. Zone Index The zones are designated as follows: ZONE # RANGE ZONE FUNCTION ACTUAL ZONE 001 – 250 Protection zones As indicated 601 – 632 Relay Supervisory Zones 6 + 2-digit Relay Number; e.g., Relay Number 03 is zone 603. 800 – 830 ECP Device Supervisory Zones 8 + 2-digit Device Address; e.g., Device Address 01 is zone 801. VIP Module is zone 804 (Device Address must be set to 4). TeleSmart is zone 824 (Device Address must be set to 24). 970, 988, 990, & 997 System Supervisory Zones 970: Bell Supervision 988: 2nd Wireless Receiver – not receiving signals 990: 1st Wireless Receiver – not receiving signals 997: Polling Loop (short circuit) 992, 995 – 999 Duress and Keypad Panics 992: Duress 995: 1 + ✳ panic (A key) 996: 3 + # panic (C key) 999: ✳ + # panic (B key) Program supervisory zones with response type of 05. Communication Defaults *45 PRIMARY FORMAT [1] ADEMCO Contact ID *46 LOW SPEED FORMAT (Prim) [0] ADEMCO Low Speed *47 SECONDARY FORMAT [1] ADEMCO Contact ID *48 LOW SPEED FORMAT (Sec.) [0] ADEMCO Low Speed *49 CHECKSUM VERIFICATION [0] [0] No checksum Primary Secondary *50 SESCOA/RADIONICS SEL. [0] Radionics *51 DUAL REPORTING [0] no *52 STANDARD/EXPANDED REPORT FOR PRIMARY [0] [0] [0] [0] [0] [0] standard Alarm Rstr Bypass Trbl Opn/Cls Low Bat *53 STANDARD/EXPANDED REPORT FOR SECONDARY [0] [0] [0] [0] [0] [0] standard Section 4 – Programming 4-5 Alarm Rstr Bypass Trbl Opn/Cls Low Bat Communication Defaults for Zones ZONE # 1st 2nd ZONE # 1st 2nd ZONE # 1st 2nd ZONE # 1st 2nd 1 01 00 50 05 00 99 09 00 148 13 00 2 02 00 51 06 00 100 10 00 149 14 00 3 03 00 52 07 00 101 11 00 150 15 00 4 04 00 53 08 00 102 12 00 151 01 00 5 05 00 54 09 00 103 13 00 152 02 00 6 06 00 55 10 00 104 14 00 153 03 00 7 07 00 56 11 00 105 15 00 154 04 00 8 08 00 57 12 00 106 01 00 155 05 00 9 09 00 58 13 00 107 02 00 156 06 00 10 10 00 59 14 00 108 03 00 157 07 00 11 11 00 60 15 00 109 04 00 158 08 00 12 12 00 61 01 00 110 05 00 159 09 00 13 13 00 62 02 00 111 06 00 160 10 00 14 14 00 63 03 00 112 07 00 161 11 00 15 15 00 64 04 00 113 08 00 162 12 00 16 01 00 65 05 00 114 09 00 163 13 00 17 02 00 66 06 00 115 10 00 164 14 00 18 03 00 67 07 00 116 11 00 165 15 00 19 04 00 68 08 00 117 12 00 166 01 00 20 05 00 69 09 00 118 13 00 167 02 00 21 06 00 70 10 00 119 14 00 168 03 00 22 07 00 71 11 00 120 15 00 169 04 00 23 08 00 72 12 00 121 01 00 170 05 00 24 09 00 73 13 00 122 02 00 171 06 00 25 10 00 74 14 00 123 03 00 172 07 00 26 11 00 75 15 00 124 04 00 173 08 00 27 12 00 76 01 00 125 05 00 174 09 00 28 13 00 77 02 00 126 06 00 175 10 00 29 14 00 78 03 00 127 07 00 176 11 00 30 15 00 79 04 00 128 08 00 177 12 00 31 01 00 80 05 00 129 09 00 178 13 00 32 02 00 81 06 00 130 10 00 179 14 00 33 03 00 82 07 00 131 11 00 180 15 00 34 04 00 83 08 00 132 12 00 181 01 00 35 05 00 84 09 00 133 13 00 182 02 00 36 06 00 85 10 00 134 14 00 183 03 00 37 07 00 86 11 00 135 15 00 184 04 00 38 08 00 87 12 00 136 01 00 185 05 00 39 09 00 88 13 00 137 02 00 186 06 00 40 10 00 89 14 00 138 03 00 187 07 00 41 11 00 90 15 00 139 04 00 188 08 00 42 12 00 91 01 00 140 05 00 189 09 00 43 13 00 92 02 00 141 06 00 190 10 00 44 14 00 93 03 00 142 07 00 191 11 00 45 15 00 94 04 00 143 08 00 192 12 00 46 01 00 95 05 00 144 09 00 193 13 00 47 02 00 96 06 00 145 10 00 194 14 00 48 03 00 97 07 00 146 11 00 195 15 00 49 04 00 98 08 00 147 12 00 196 01 00 197 02 00 215 05 00 232 07 00 249 09 00 198 03 00 216 06 00 233 08 00 250 10 00 199 04 00 217 07 00 234 09 00 601-632 00 00 200 05 00 218 08 00 235 10 00 800-830 00 00 201 06 00 219 09 00 236 11 00 970 00 00 202 07 00 220 10 00 237 12 00 988 00 00 203 08 00 221 11 00 238 13 00 990 00 00 204 09 00 222 12 00 239 14 00 992 (DURESS) 11 00 205 10 00 223 13 00 240 15 00 995 00 00 206 11 00 224 14 00 241 01 00 996 00 00 207 12 00 225 15 00 242 02 00 997 06 00 208 13 00 226 01 00 243 03 00 999 06 00 VISTA-128BP/VISTA-250BP Installation and Setup Guide 4-6 ZONE # 1st 2nd ZONE # 1st 2nd ZONE # 1st 2nd ZONE # 1st 2nd 209 14 00 227 02 00 244 04 00 ALARM RST. 00 00 210 15 00 228 03 00 245 05 00 TROUBLE 00 00 211 01 00 229 04 00 246 06 00 TRBLE. RST 00 00 212 02 00 230 05 00 247 07 00 BYPASS 00 00 213 03 00 231 06 00 248 08 00 BYP. RST. 00 00 214 04 00 Zone Response Type Definitions Each zone must be assigned a zone type, which defines the way in which the system responds to faults in that zone. There are three keypad-activated zones (panic keys; see note) for each partition, a polling loop supervision zone, and four RF supervisory zones, two for each RF receiver installed. Zone types are defined below. Type 00: Zone Not Used Program with this zone type if the zone is not used. Type 01: Entry/Exit #1 Burglary Provides entry delay whenever the zone is faulted and the system is armed in the AWAY or STAY mode. When the panel is armed in the INSTANT or MAXIMUM mode, no entry delay is provided. Exit delay begins whenever the control is armed, regardless of the arming mode selected. These delays are programmable. Assign this zone type to zones that are used for primary entry to and exit from the facility. Type 02: Entry/Exit #2 Burglary Provides a secondary entry delay, if the system is armed in the AWAY or STAY modes and the zone is faulted. When the panel is armed in the INSTANT or MAXIMUM mode, no entry delay is provided. Secondary exit delay begins whenever the control is armed, regardless of the arming mode selected. These delays are programmable. Assign this zone type to zones that are used for entry and exit of the facility and require more time than the primary entry and exit point. Delay times for this zone type must be greater than those for zone type 01 (e.g., a garage, loading dock, or basement door). Type 03: Perimeter Burglary Provides an instant alarm if the zone is faulted and the system is armed in the AWAY, STAY, INSTANT, or MAXIMUM mode. Assign this zone type to all exterior door and window zones. Type 04: Interior, Follower Provides a delayed alarm (using the programmed entry delay time) if an entry/exit zone is faulted first. Otherwise it produces an instant alarm. It is active when the system is armed in the AWAY or MAXIMUM mode, but the MAXIMUM mode eliminates the entry delay. If the Interior Follower zone is programmed for one of the STAY modes (default is STAY mode 1), it is automatically bypassed when the panel is armed in the STAY or INSTANT mode. Assign this zone type to a zone covering an area such as a foyer, lobby, or hallway through which one must pass upon entry or exit (to and from the keypad). Type 05: Trouble by Day/Alarm by Night Provides an instant alarm if the zone is faulted and the system is armed in the AWAY, STAY, INSTANT, or MAXIMUM mode. During the disarmed state (day), the system annunciates a latched trouble sounding from the keypad (and a central station report, if desired). Assign this zone type to a zone that contains a foil- protected door or window (such as in a store), or to a zone covering a sensitive area such as a stock room or drug supply room. It can also be used on a zone in an area where immediate notification of an entry is desired. Type 06: 24-Hour Silent Alarm Sends a report to the central station but provides no keypad display or sounding. Assign this zone type to a zone containing an Emergency button. Type 07: 24-Hour Audible Alarm Sends a report to the central station and provides an alarm sound at the keypad and an audible external alarm. Assign this zone type to a zone containing an Emergency button. Type 08: 24-Hour Auxiliary Alarm Sends a report to central station and provides an alarm sound at the keypad only. (No bell output is provided.) Assign this zone type to a zone an Emergency button or one containing monitoring devices such as water sensors or temperature sensors. Type 09: Supervised Fire (Without Verification) Section 4 – Programming 4-7 Provides a fire alarm on a short circuit and a trouble condition on open circuit. A fire alarm produces a pulsing of the bell output. A zone of this type is always active and cannot be bypassed. Type 10: Interior with Delay Provides entry and exit delays (using the programmed entry and exit delay times) when armed in the AWAY mode. Provides only exit delay when armed in the MAXIMUM mode (no entry delay). If the Interior with Delay zone is programmed for one of the STAY modes (default is STAY mode 1), it is automatically bypassed when the panel is armed in the STAY or INSTANT mode. Delay begins whenever sensors in this zone are violated, regardless of whether or not an entry/exit delay zone was tripped first. Assign this zone type to a zone covering an area such as a foyer, lobby, or hallway through which one must pass upon entry or exit (to and from the keypad). Type 14: PLM Supervision Provides supervision of remote Panel Link Modules. If the communication between the local PLM and a remote PLM fails, a trouble message is produced for the PLM zone. Type 16: Fire With Verification Provides a fire alarm on a short circuit and a trouble condition on open circuit. An initial short detection causes 7-second smoke detector power reset. A subsequent short detection within 90 seconds of the reset causes a fire alarm. A fire alarm produces a pulsing of the bell output. A zone of this type is always active and cannot be bypassed. Type 20: Arm-STAY (5800 Series devices only) Causes the system to arm in the STAY mode when the zone is activated. Type 21: Arm-AWAY (5800 Series devices only) Causes the system to arm in the AWAY mode when the zone is activated. Type 22: Disarm (5800 Series devices only) Causes the system to disarm when the zone is activated. Type 23: No Alarm Response Used on a zone when an output relay action is desired, but with no accompanying alarm (e.g., for lobby door access). Type 27: Access Point Assign this zone type to an input device (hardwired zone, wireless zone, keypad, access control relay, etc.) that controls an access entry point (e.g., a door). The access point entry relay can be assigned to an access control relay (controlled by the VISTA-128BP/VISTA- 250BP), ECP relay (4204), or to the access control system independent of the control panel. Type 28: Main Logic Board (MLB) Supervision Used to supervise the MLB. If communication between the MLB and the VISTA Gateway Module (VGM) fails, a trouble condition is annunciated for the zone. Also, if the communication fails, all access control system (ACS) input zones also display a “CHECK.” Type 29: Momentary Exit Used to cause an access point programmed for entry to revert to an exit point for 15 seconds. After the 15 seconds, it automatically reverts back to an entry point. This zone type should be used only with VistaKey modules. NOTE FOR PANIC KEYS: Keypad panic zones share the same zone response type for all 8 partitions, but panics may be individually enabled for each partition. IMPORTANT! FAULT ANNUNCIATION Polling loop and RF troubles (zones 988, 990, and 997) report as trouble conditions only, and as such, should be assigned zone type 05 if annunciation is desired. See Polling Loop Supervision and RF System Operation and Supervision in SECTION 3 Installing the Control for more information. Zone Input Type Definitions Each zone must be assigned an input type, which defines the where the system will “look” for status of the zone (RF receiver, polling loop, etc.). Zone input types are defined below. Type 01 Hardwired (HW) Reserved for the built-in hardwired zones 1-9. Type 02 RF Motion (RM) Select for 5800 Series RF transmitters. Sends periodic check-in signals, as well as fault and low-battery signals. The control panel automatically restores the zone to “ready” after a few seconds. This type is designed for facilities with multiple motion detectors that may fault and restore simultaneously. The transmitter must remain within the receiver’s range. NOTE: If using RF Motion with a door/window type transmitter, only loop 1 may be used. Type 03 Supervised RF (RF) Select for 5800 Series RF transmitters that will be supervised for check-in signals. The transmitter must remain within the receiver’s range. Type 04 Unsupervised RF (UR) Select for 5800 Series RF transmitters that will not be supervised for check-in signals. The transmitter may therefore be carried off-premises. VISTA-128BP/VISTA-250BP Installation and Setup Guide 4-8 Type 05 Unsupervised Button RF (BR) Select for 5800 Series RF transmitters specifically designed for this input type. Check the transmitter’s instructions for proper programming of the input type. These transmitters send only fault signals. They do not send low-battery signals until they are activated. The transmitter may be carried off-premises. Type 06 Serial Number Polling Loop (SL) Select for polling loop devices with a built-in serial number. For VistaKey, select this type for Door Status Monitor Backup DSMB. If local power to the VistaKey is lost, a V-Plex SIM, located on the VistaKey board, is powered directly from the polling loop and reports the state of the DSM via the standard V-Plex polling system. NOTE: To obtain the DSMB function, the Input Type must be defined as 06 and the next prompt in Zone Programming (Access Point) must contain the Access Point number (01-15) (address of the VistaKey module). Type 07 DIP Switch Loop (DP) Select for polling loop devices that use DIP switches for programming the zone number of the device. Type 08 Dip Switch Polling Loop Right Loop (PS) Select for the second loop of two-zone polling loop devices (e.g., 4190WH; 4278). Type 09 Console Input (CS) Select when this zone is to be controlled by a keypad input (user code + [#] + [7] + [3]) for access control. Type 10 PassPoint Access Control (ACS) Select when this zone is mapped to a zone on the PassPoint Access Control System. Type11 VistaKey Door Status Monitor (DSM) Select this input type when using a VistaKey module connected to a door. This must be programmed for each VistaKey module to provide the DSM zone mapping a panel zone. If this is not programmed the panel will not “see” the VistaKey module. It is also used to determine the door is opened after a card swipe or if the door is being held open. The device is normally a magnetic switch mounted on the door. The status of the switch is different when the door is in an open position. Type 12 VistaKey Request to Exit (RTE) Use this input type to map an uncommitted RTE zone to an alarm panel zone. This input type is not normally used if the zone is used for a request-to-exit function. Type 13 VistaKey General Purpose (GP) This input type operates in the same manner as other VISTA-128BP/VISTA-250BP alarm panel zones and is provided so that a zone in the proximity of the VistaKey can be wired without having to run additional wiring from the control panel. Programming for Panel Linking Step Action 1 Program the Panel Link Module (PLM) into the system in Device Programming in the #93 Menu Mode with Device Type 10. 2 If you want to supervise the PLM, program zone 8xx with response type 05, where “xx” = the module’s address. If you want the zone to report to the central station, make sure the report code for the zone is set with a non-zero value. Step Action 3 If you want to supervise the PLMs connected to other controls, program those modules in Zone Programming with response type 14. Also, program the panel ID number. The ID number must match the ID number programmed in Device Programming of the control panel the PLM is connected. If you want the zone to report to the central station, make sure the report code for the zone is set with a non-zero value. Be sure to program the input type with 00. See Device Programming and Zone Programming in #93 Menu Mode Programming in the Programming Guide for a detailed explanation of the programming procedures. Programming for the Alpha Pager Module • ✳05 Enter 1 to print all zone faults/restores; enter 0 to print only events enabled in field 1✳70 • ✳14 Enter 1 if using Home Automation • 1✳69 Printer selection 0 for parallel; 1 for serial • 1✳70 Event Log Types (1=enable; 0=disable) • 1✳71 12/24-Hour Time Stamp (0=12 hr; 1=24 hr) • 1✳72 Printer On-line (must be 1 (enable) for APM) • 1✳73 Enter 0 for 1200 Baud Rate Section 4 – Programming 4-9 • 2✳30 Enter 1 to enable the Alpha Pager Module. • 2✳31 - 2✳88 Paging service parameters. The events (e.g., field 2*39) must be programmed for the pager to work. Fields for programming the delay times (e.g. 2*36 and 2*37 for pager 1) are relevant only when using numeric format for the pager. NOTE: For Event Log Report Codes program System Group #2 in the #93 Menu Mode. Programming for 4100SM • ✳05 Enter 1 to print all zone faults/restores; enter 0 to print only events enabled in field 1✳70 • ✳14 Enter 1 if using Home Automation (cannot use both serial printer and Home Automation) • 1✳69 Not applicable • 1✳70 Event Log Types (1=enable; 0=disable • 1✳71 12/24-Hour Time Stamp (0=12 hr; 1=24 hr) • 1✳72 Printer On-line (0=disable; 1=enable) • 1✳73 Enter 0 for 1200 Baud Rate NOTE: For Event Log Report Codes program System Group #2 in the #93 Menu Mode. Programming for Access Control VistaKey See the VistaKey-SK Installation and Setup Guide for the detailed programming instructions. VistaKey Dialer Enables When the VistaKey is installed with an alarm system, the system defaults are set so that the system does not send reports to the central station. The programming is accomplished in field 1∗35 for the following events: • ACS Troubles - To enable or disable ACS trouble reporting. • ACS Bypasses - To enable or disable ACS bypass reporting. • ACS System - To enable or disable ACS system reporting, (i.e., ACS module reset). • ACS Alarms - To enable or disable ACS alarm reporting. • Dialer (Trace) - To enable or disable access grant/denial events sent to the central station. PassPoint The PassPoint ACS can dedicate some of its inputs for use as regular VISTA-128BP/VISTA-250BP hardwired zones (the zone response type is ACS). The PassPoint ACS can also utilize the control panel dialer for reports to the central station. PassPoint Dialer Events All PassPoint ACS events can be sent to the VISTA- 128BP/VISTA-250BP dialer via the VGM. These events will also be logged into the control’s event log. This is enabled in the PassPoint ACS. See the PassPoint ACS documentation for a detailed explanation. Programming the VISTA Gateway Module See the PassPoint ACS instructions to program the VISTA Gateway Module. Using ACS Zone Inputs If the PassPoint ACS has uncommitted zones, these may be used by the VISTA-128BP/VISTA-250BP as hardwired zones. To program for ACS zone inputs, perform the following steps: Step Action 1 Enter Zone Programming in the #93 Menu Mode. 2 Program this zone as any other zone. Indicate the input type as ACS (10). 3 Enter the PassPoint ACS’s zone ID (00-31) See Zone Programming in the Programming Guide for a detailed explanation. Access Control of an Entry/Exit Point The control can send entry and exit requests to the VistaKey or PassPoint ACS utilizing keypads and button-type (BR) RF transmitters. A zone is programmed with a response type 27 (Access Point) and an appropriate input type (console, RF). Using the Alpha Keypad Step Action 1 Enter Zone Programming in the #93 Menu Mode. 2 Program the zone with a response type 27 (Access Point). 3 Enter the access point number (00-31) of the door. 4 Program whether this is an entry or exit point. 5 Enter the partition number. 6 Enter the input type as CS (09). 7 Enter the keypad ECP address. See Zone Programming in the Programming Guide for a detailed explanation. Using Wireless Keypads Wireless keypads (5827 & 5827BD) can provide another way of entering or exiting the premises. They VISTA-128BP/VISTA-250BP Installation and Setup Guide 4-10 function the same as alpha keypads, except when the code + # 73 is entered. This entry will allow momentary access to ALL access points in the partition to which the keypad is assigned. To program the wireless keypad, enter the partition the keypad is assigned to in field 1*48. Using an RF Transmitter Zone A button type RF transmitter (5804) can be used to provide access or egress for up to 4 doors. One button will control one door. Also, a button can be used to provide access or egress due to a panic or duress condition. An RF transmitter (5816) can be used with a remote switch to provide exit in case of a fire alarm using a PassPoint event action. To program the RF transmitter for access control, perform the following steps: Step Action 1 Enter Zone Programming in the #93 Menu Mode. 2 Program the zone with a response type 27 (Access Point). 3 Enter the access point number (00-31) of the door. 4 Indicate whether RF device is for entry or exit. 5 Enter the partition number 6 Enter the input type: button RF (03). 7 Enter the loop number. 8 Enroll the serial number See Zone Programming in the Programming Guide for a detailed explanation. • RF buttons and pendants must be assigned to a user number in order to function. See SECTION 9: User Access Codes for the procedure. • An RF transmitter will not provide access or grant if the system is in any test mode. Control of Lighting and Appliances Lighting and appliances can be controlled when an access or exit event occurs. Lights or appliances can be automatically turned on or off when a valid entry or egress request is presented at an access point. To control these devices, the VISTA-128BP/VISTA-250BP relays or the ACS relays or triggers are used with keypads and/or RF transmitters whose response type is Access Point (27). To program the control of lighting and appliances, perform the following steps: Step Action 1 Enter Output Programming in the #93 Menu Mode. 2 Program all the information for the relay. 3 Select the output type: ECP (1) (4204) or (2) (X-10). See Output Programming in the Programming Guide for a detailed explanation. Using the VISTA-128BP/VISTA-250BP for Stand- Alone Access Control The VISTA-128BP/VISTA-250BP can be used for access control without interfacing to PassPoint ACS or VistaKey. A user can trigger an access point (i.e., door strike) for 2 seconds by entering User Code + [0]. To program the VISTA-128BP/VISTA-250BP for Stand- Alone access control, perform the following steps: Step Action 1 Enter Output Programming in the #93 Menu Mode. 2 Program the output type as 1, or 2. 3 For type 1, program the ECP address and relay number. 4 For type 2, program the house and unit codes. 5 Program the relay number in field 1∗76 (partition-specific). See Output Programming in the Programming Guide for a detailed explanation. Programming for ECP Long Range Radio • Program the LRR in Device Programming in the #93 Menu Mode Programming. • Field ✳56: Selects the time the panel should wait before it attempts to send a message to the second destination. • Field ✳57: Select the initial reporting destination for messages. • Field ✳58: Select events for the primary sub’s ID • Field ✳59: Select events for the secondary sub’s ID. Programming for TeleSmart The TeleSmart module has a fixed address of 24 (it cannot be changed). Set Device Address 24 for Device Type 11 in the control’s Device Programming mode. Also, Device Address 23 must be set for Device Type 01, Alpha Console, but do not actually connect a device to the control panel set to that address. Section 4 – Programming 4-11 This must be done so that TeleSmart can be accessed remotely (off premises). Refer to Device Programming in the #93 Menu Mode in the VISTA-128BP/VISTA-250BP Programming Guide for specific instructions. 5-1 SECTION 5 Data Field Descriptions •••••••••••••••••••••••••••••••••••••••••••••••• • About Data Field Programming The following pages list this control’s data fields in numerical order. Field numbers are listed in the left column, followed by a “Title and Data Entries column, which lists the valid entries for each field. Experienced installers can simply follow this column when programming the data fields. The “Explanation” column provides explanatory information and special notes where applicable. NOTE: Refer to the Programming Guide for the default values. They are not listed in this section. Use the Programming Guide to record the data for this installation. NOTE: All references in this manual for number of zones, number of user codes, number of access cards, and the event log capacity, use the VISTA-250BP’s features. See SECTION 1: General Description for the table listing the differences between the VISTA-128BP and the VISTA-250BP control panels. All other features are identical, except for the Remote Keypad Sounder (field 1✴46 option 2), which is available only in the VISTA128BP. Programming Data Fields Data field programming involves making the appropriate entries for each of the data fields. Start Data Field programming by entering the installer code + 8 + 0 + 0 + 0. FIELD TITLE and DATA ENTRIES EXPLANATION *00 Installer Code Enter 4 digits, 0-9 The Installer Code is a 4-digit code reserved for installation company use. This is the only code that can be used to enter the Program Mode from the keypad. This code cannot be used to disarm the system if it isn’t used to arm the system. This code cannot be used to re-enter Program Mode if Program Mode is exited by the *98 command. *04 Enable Random Timers For Partitions 1-8 0 = disable 1 = enable If enabled, the activation time of the window is randomized up to 30 minutes and is initialized by either of two methods: User Code + [#] + [41] Initiates the random schedule for all devices in the partition. User Code + [#] + [42] Initiates the random schedule for all devices in the partition with a time window within 6 PM and 5 AM. *05 System Events Notify 0 = disable 1 = enable If enabled the system sends notification messages via the RS232 port. Field *14 must be set for RS232 port (1). NOTE: If enabled, the system also sends fault and restore messages via the RS232 port. Quick Exit (partition-specific) 0 = disable 1 = enable If enabled, allows users to exit the armed partition without disarming and then rearming the partition. Quick Exit is initiated by entering [#] + [9]. This restarts the exit delay. All rules of exit apply, including exit error logic. UL Quick Exit is not permitted for use with the VISTA-128BP/VISTA-250BP Control Panel in a UL installation. *06 VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-2 FIELD TITLE and DATA ENTRIES EXPLANATION *09 Entry Delay #1 (partition-specific) Enter 02-15 multiplied by 15 seconds. 00 = no delay. Entry delay defines the delay time that allows users to re-enter the premises through a door that has been programmed as an entry delay door and disarm the system without sounding an alarm. The system must be disarmed within this period or an alarm will occur. NOTE: The delay may not exceed 45 seconds for UL installations. SIA Guidelines: The entry delay time and Burg Alarm Comm Delay (field *88) combined cannot exceed 1 minute. *10 Exit Delay #1 (partition-specific) Enter 03-15 multiplied by 15 seconds. 00 = no delay. Exit delay defines the delay period that allows users to leave the premises through a door that has been programmed as an entry/exit delay door after arming the system without setting off the alarm. NOTE: SIA Guidelines: The delay must be set for a minimum 45 seconds. *11 Entry Delay #2 (partition-specific) Enter 02-15 multiplied by 15 seconds. 00 = no delay. Entry Delay #2 is used for a secondary door requiring a longer delay than those assigned to Entry Delay #1. NOTE: The delay may not exceed 45 seconds for UL installations. SIA Guidelines: The entry delay time and Burg Alarm Comm Delay (field *88) combined cannot exceed 1 minute. *12 Exit Delay #2 (partition-specific) Enter 03-15 multiplied by 15 seconds. 00 = no delay. Exit Delay #2 is used for a secondary door requiring a longer delay than those assigned to Exit Delay #1. NOTE: The delay may not exceed 60 seconds for UL installations. SIA Guidelines: The delay must be set for a minimum 45 seconds. *13 Alarm Sounder Duration (partition-specific) Enter 01-15 multiplied by 2 minutes. 00 = no timeout. Defines the length of time the Bell Output and the keypad’s sounder will sound for all audible alarms. Must be minimum 16 minutes for UL Commercial Burglary installations. SIA Guidelines: Must be minimum 6 minutes. Burglary or RS232 Input 0 = burglary 1 = RS232 input If enabled, sets terminal 23 (high side (+) of zone 9) as an RS232 input. This enables the system to receive serial data (75 baud) via terminal 23. UL Using the RS232 input for automation is not permitted in UL installations. *14 *15 Keyswitch Assignment Enter 1-8 partition keyswitch is being used. Enter 0 if the keyswitch is not used. The keyswitch requires the use of zone 7 wired loop (zone 7 is no longer available as protection zone). The fire and panic alarm voltage triggers (J7) automatically become ARMING and READY status outputs for the Keyswitch LEDs. Openings/closing report as user “0” if enabled in field *40. *16 Confirmation of Arming Ding (partition-specific) 0 = disable 1 = enable If enabled, produces ½-second external alarm sounding (“ding”) at the end of exit delay (or after kissoff from the central station, if sending closing reports). Must be 1 for UL installations. *17 AC Loss Keypad Sounding 0 = disable 1 = enable If enabled, sounding at the keypad (rapid beeping) occurs when AC power is lost (sounding occurs about 2 minutes after actual AC loss). *19 Randomize AC Loss Report 0 = disable 1 = enable If enabled, randomizes AC loss reporting between 10 and 40 min. after an actual AC loss. If disabled, AC loss reporting about 2 minutes after actual AC loss. Selecting this option helps prevent an overload of AC loss messages at the central station during a community blackout. FIELD TITLE and DATA ENTRIES EXPLANATION Section 5 – Data Field Descriptions 5-3 *20 VIP Module Phone Code 1-9 = first digit of access code ∗∗∗∗ or # = second digit of access code (enter # +11 for “∗”, or # +12 for “#”) To disable enter 00 for the 1st digit If a 4285/4286 Voice Module is being used, enter the 2-digit phone code used to access the system. Must be disabled for UL installations. *21 Prevent Fire Timeout 0 = disable (timeout) 1 = enable (no timeout) If enabled, there is no timeout of the alarm sounder duration for all fire zones, regardless of partition, so that fire sounding continues until the system is reset. If disabled, (timeout) the normal burglary sounder duration (field ✳13) applies to fire alarms. *22 Keypad Panic Enables (partition- specific) 0 = disable 1 = enable If enabled, the keypad panics (zones 995, 996, and 999) may be used in this partition. There are 3 entries in this field, one for each panic. *23 Multiple Alarms (partition- specific) 0 = disable 1 = enable If enabled, allows more than one alarm sounding for a given zone during an armed period. NOTE: that multiple alarm soundings will not occur more frequently than allowed by the programmed alarm sounder duration. This has no impact on the number of communication messages transmitted. Must be 1 for UL installations. *24 Ignore Expansion Zone Tamper 0 = disable (tamper detection) 1 = enable (no tamper detection) If disabled, the system monitors the tampers on expansion zones. NOTE: Only applicable to certain polling loop sensors with tamper switches or 5800 Series transmitters. Must be 0 for UL installations. *25 Burglary Trigger for Response Type 8 0 = disable 1 = enable If enabled, allows triggering of Output 3 (pin 7) of the J7 header to include zone response type 8 (24-hr. auxiliary). *26 Intelligent Test Report 0 = disable 1 = enable If enabled, no test report is sent if any other type of report was sent since the last test report. If disabled, test reports are sent at the set intervals, regardless of whether or not any other report has been sent. Must be 0 for UL applications. *27 Test Report Interval Enter 0001-9999 for the test report interval in hours. Enter 0000 for test reporting. If a test report is desired, enter a test code in Report Code Programming in #93 Menu Mode. Set first test report time in field *83. Maximum Test report interval is 0024 for UL installations. *28 Power-Up in Previous State 0 = disable 1 = enable If enabled, the system, upon power-up, reverts to its status prior to a complete power loss. If disabled, the system always powers up in a disarmed state. NOTE: Neither authority level 0 nor 5 can be used to disarm the system if the control powers up armed. Must be 1 for UL applications. *29 Quick Arm (partition-specific) 0 = disable 1 = enable If enabled, allows arming of the burglary system in AWAY, STAY, INSTANT, or MAXIMUM mode by using the [#] key instead of the user code. NOTES: When armed, the system reports closing as User 0 if Open/Close reporting for User #2 (typically a Master level user) was enabled for a given partition. If Quick Arm is used, the Installer Code and Authority Level 5 codes cannot disarm the system. FIELD TITLE and DATA ENTRIES EXPLANATION VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-4 TouchTone or Rotary Dial 0 = disable 1 = enable Select the dialing method for the system If you select TouchTone, make sure the subscriber has requested and is paying for TouchTone service. Note that whether or not TouchTone dialing for call placement is permitted, communication by the use of DTMF signaling (ADEMCO High Speed) will still take place. See field 1*33 for TouchTone w/Rotary backup *30 *31 PABX Access Code Enter 00-09; B-F (11-15) This field is used to enter up to four 2-digit numbers representing the prefix needed to obtain an outside telco line. If not required, enter nothing and proceed to next field. *32 Primary Subscriber’s Account Number (partition-specific) Enter 00-09; B-F (11-15) Enter a 3- or 4-digit (depending on report format) primary subscriber account number. Each number requires a 2-digit entry so as to allow entry of hexadecimal digits (B-F). If a 3-digit account number is to be used, enter data only in the first 3 locations, and enter * in the fourth location. *33 Primary Phone Number Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause. Enter the primary central station phone number, up to 17 digits. This is the phone number the control will use to transmit Alarm and status messages to the central station. Do not fill unused spaces. NOTE: Backup reporting is automatic only if a secondary phone number is entered. *34 Secondary Phone Number Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause. Enter the secondary phone number, up to 17 digits. The secondary phone number is used if communication on the primary number is unsuccessful, or if split/dual reporting is desired. Do not fill unused spaces. NOTE: If this field is programmed, a secondary subscriber account number (field *90) must also be programmed. *35 Download Phone Number Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause. Enter the downloading phone number, up to 17 digits. Do not fill unused spaces. NOTE: This field is applicable only if downloading is utilized. *36 Download ID Number Make entries as 2-digit numbers as follows: 00=0 01=1 02=2 03=3 04=4 05=5 06=6 07=7 08=8 09=9 10=A 11=B 12=C 13=D 14=E 15=F Enter eight digits. NOTE: This field is applicable only if downloading is utilized. *37 Download Command Enables 0 = disable 1 = enable Enabling a function means that you are able to perform that function via the ADEMCO Compass Downloading software. Functions are as follows: Dialer Shutdown; System Shutdown; Not Used; Remote Bypass; Remote Disarm; Remote Arm; Upload Program; Download Program. For UL installations, all entries must be 0. *38 Prevent Zone XXX Bypass (partition-specific) Enter a zone number (001-250). Enter 000 if all zones can be bypassed. Enter three digits for zone that cannot be bypassed by the user. NOTES: The actions manual bypass, group bypass, auto-stay, and STAY/INSTANT arming modes cannot bypass any zone programmed in this field. The system will not arm if the zone is programmed with the vent zone or force arm fault attributes. *39 Enable Open/Close Report for Installer Code (partition-specific) 0 = disable 1 = enable If enabled, whenever the Installer Code is used to arm or disarm the partition, an open/close report is sent to the central station. FIELD TITLE and DATA ENTRIES EXPLANATION Section 5 – Data Field Descriptions 5-5 *40 Enable Open/Close report for Keyswitch 0 = disable 1 = enable If enabled, whenever the keyswitch is used to arm or disarm the partition, an open/close report is sent to the central station. *41 Normally Closed or EOLR (Zones 2-8) 0 = EOLR used 1 = normally closed If 0, end-of-line resistors must be used on zones 2-8. If 1 end-of-line resistors cannot be used and only normally closed devices must be used. Must be 0 for UL installations. *42 Dial Tone Pause Enter the wait time for dial tone detection: 0 = 5 seconds; 1 = 11 seconds; 2 = 30 seconds. Enter the time the system waits for dial tone before dialing. Applies if true dial tone is not selected in field *43. Must be 0 for UL installations. *43 Dial Tone Detection 0 = disable 1 = enable If enabled, the system waits for true dial tone. If no dial tone is detected, control dials at end of pause programmed in field *42. If disabled, the system pauses for seconds entered in field *42, then dials. NOTE: Disabling may be necessary in high-noise environment telco networks where noise can be confused with dial tone, resulting in premature dialing. *44 Ring Detection Count Enter 00 to disable ring detection. Enter 01-14 for ring counts of 1-14. Enter 15 to select Answering Machine Defeat Mode Only applicable if using a 4285/4286 VIP Module and/or if station-initiated downloading will be used. NOTES: Do not enter 00 if a 4285/4286 is installed. In the Answering Machine Mode, the caller should let the phone ring once, then hang up, and call again within 30 seconds. The system, upon hearing one ring followed by nothing, does not answer the first call, but readies itself to pick up on the first ring of the next incoming call that is received within 30 seconds (i.e., the downloader calling again). Must be 00 for UL installations. *45 Primary Format 0=Low Speed; 1=Contact ID; 2=ADEMCO High Speed; 3=ADEMCO Express Enter the reporting format for the primary telephone number. *46 Low Speed Format (Primary) 0 = ADEMCO Low Speed 1 = Sescoa/Radionics Enter the low speed format for the primary telephone number. *47 Secondary Format 0=Low Speed; 1=Contact ID; 2=ADEMCO High Speed; 3=ADEMCO Express Enter the reporting format for the secondary telephone number. *48 Low Speed Format (Secondary) 0 = ADEMCO Low Speed 1 = Sescoa/Radionics Enter the low speed format for the secondary telephone number. *49 Checksum Verification Enter 2 digits, one for the primary and one for the secondary. 0 = disable 1 = enable If enabled, the system for either or both primary/secondary formats sends a verification digit to validate the message at the receiver without having to send two message rounds. Selection is valid for 3+1, 4+1, and 4+2 reports. *50 Sescoa/Radionics Select 0 = Radionics 1 = Sescoa Radionics selection uses hexadecimal 0-9, B-F reporting. Sescoa selection uses only numeric reporting (0-9). NOTE: The selection applies to both primary and secondary phone numbers. FIELD TITLE and DATA ENTRIES EXPLANATION VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-6 *51 Dual Reporting 0 = disable 1 = enable If enabled, all reports are to be sent to both primary and secondary phone numbers. NOTE: If used with Split Reporting option 1 (1*34), alarms go to both primary and secondary numbers, while all other reports go to secondary only. If used with Split Reporting option 2, alarms go to both lines, open/close and test messages go to secondary only, while all other reports go to primary. *52 Standard/Expanded Reporting Primary 0 = disable 1 = enable This field has six entries as follows: Alarm, Restore, Bypass, Trouble, Open/Close, Low Battery. If enabled, expanded reports are sent to the primary phone number if low speed format is selected in field *45. NOTE: Expanded overrides 4+2 format. *53 Standard/Expanded Reporting Secondary 0 = disable 1 = enable This field has six entries as follows: Alarm, Restore, Bypass, Trouble, Open/Close, Low Battery. If enabled, expanded reports are sent to the secondary phone number if low speed format is selected in field *47. NOTE: Expanded overrides 4+2 format. *54 Unattended Mode 0 = disable 1 = enable If enabled, the system automatically calls the downloader at programmed intervals. NOTE: The following fields must be programmed first: primary subscriber account number – field *32; primary phone number – field *33; downloader phone number – field *35. Or you can go into the Unattended Program Mode, from normal operating mode, by entering Installer Code + [#] + [8] + [9]. *56 Dynamic Signaling Delay Enter 00-15 times 15 seconds. Select the time the panel should wait for acknowledgment from the first reporting destination before it attempts to send a message to the second destination (first and second destinations are determined in field ✳57). NOTE: If the acknowledgment is received before the delay time expires, no message is sent to the second destination. *57 Dynamic Signaling Priority 0 = Primary Dialer 1 = Long Range Radio Select the initial reporting path for central station messages. *58 Long Range Radio Central Station #1 Category Enable 0 = disable 1 = enable This field has six entries as follows: Alarm, Trouble, Bypass, Open/Close, System, Test. If enabled, the reports are sent to the primary subscriber ID of the Long Range Radio. *59 Long Range Radio Central Station #2 Category Enable 0 = disable 1 = enable This field has six entries as follows: Alarm, Trouble, Bypass, Open/Close, System, Test. If enabled, the reports are sent to the secondary subscriber ID of the Long Range Radio. *79 Zone Type Restores for Zone Types 1-8 0 = disable 1 = enable This field has eight entries, one for each zone type. Select the zone types that will send Restore reports. *80 Zone Type Restores for Zone Types 9, 10 and 16 0 = disable 1 = enable This field has three entries, one for each zone type. Select the zone types that will send Restore reports. *83 First Test Report Time Enter 00-07the for day (01 = Monday) Enter 00-23 for the hour Enter 00-59 for the minutes Enter the day and time that the first Test report shall be transmitted. Enter 00 in all locations if the Test report is to be sent immediately upon exiting. Enter 00 in the day location if the report is to be sent at the next occurrence of the time that is set. FIELD TITLE and DATA ENTRIES EXPLANATION Section 5 – Data Field Descriptions 5-7 *84 Swinger Suppression (partition- specific) Enter 01-15. Enter 00 for unlimited reports This option limits the number of messages (alarms or troubles) sent for a specific zone in an armed period. The system automatically resets the shutdown for a zone after 48 hours if there are no trips on any zone. Must be 00 for UL installations. *85 Enable Dialer Reports for Panics & Duress (partition-specific) 0 = disable 1 = enable This field has four entries as follows: Zone 995, 996, 999, Duress Enable for each partition that the panics and duress reporting is desired. NOTE: Non-zero report code must be assigned to zone 992 (duress) to enable Duress reporting. If you enable any of the panics to report, make sure field *22 is programmed correctly for each partition. *87 Entry Warning (partition-specific) 0 = 3 short beeps 1 = slow continuous beeps Select the type of warning for the entry delay period. *88 Burglary Alarm Communicator Delay (partition-specific) 0 = no delay 1 = 30-second delay Select the delay, if any, for burglary alarm communications. Must be 0 for UL installations. SIA Guidelines: Must be 1. *89 Restore Report Timing 0 = instant 1 = after bell timeout 2 = when system is disarmed Select the time when restore reports are sent after an alarm. Must be 2 for UL installations. *90 Secondary Subscriber Account Number (partition-specific) Enter 00-09; B-F (11-15) Enter a 3- or 4-digit (depending on report format) primary subscriber account number. Each number requires a 2-digit entry so as to allow entry of hexadecimal digits (B-F). If a 3-digit account number is to be used, enter data only in the first 3 locations, and enter * in the fourth location. NOTE: This field must be programmed if a secondary phone number is used (field *34). This account number can be the same as the primary account number. 1*07 Check or TRBL Display 0 = CHECK 1 = TRBL Select whether the system should display TRBL or CHECK for trouble conditions. 1*10 First to Alarm Display Lock 0 = scroll alarms 1 = lock display If lock display is selected, the system displays of first fire alarm and requires the user to press the [*] key for a display of each additional fire alarm. Otherwise, the system automatically scrolls all fire alarms. 1*15 Cancel Verify 0 = disable 1 = enable If enabled, the system pulses the alarm output three times and displays “Cancel Sent to Central Station” when it receives a “kissoff” of a Cancel report from the central station This message can only be cleared by entering the code + off. Enter 0 to disable. NOTE: Field 1✳52 determines when a Cancel report is sent to the central station. 1*17 Lobby Partition 0 = none 1-8 = partition number Select the Common Lobby Partition. 1*18 Affects Lobby (partition-specific) 0 = disable 1 = enable If enabled, causes lobby partition to disarm when this partition disarms. NOTE: This partition must be armed before lobby can be armed. FIELD TITLE and DATA ENTRIES EXPLANATION VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-8 1*19 Arms Lobby (partition-specific) 0 = disable 1 = enable If enabled, arming this partition causes the system to attempt to arm the lobby partition automatically. To enable this field, field 1*18 must also be enabled (partition-specific). NOTES: The lobby cannot be armed unless all partitions programmed for “affect” (field 1*18) is already armed. If his field is enabled, Field 1*18 for this partition must also be enabled. Exit Error Logic Enable 0 = disable 1 = enable Exit Error Logic functions as follows: the system at the end of the exit delay, if a door is left open or an interior zone is faulted, starts the entry delay period, and sounds the bell(s), siren(s), and keypad sounders for the duration of entry delay. This gives the user time to re-enter the premises and disarm the system before exit error occurs. If the user does not re-enter the premises and disarm the system, the system bypasses the faulted entry/exit and/or interior zone(s). The rest of the system is armed. In addition, the following dialer reports are sent to the central station if programmed: Exit Error by User (not sent when is using ADEMCO High Speed format) Entry/Exit or Interior Alarm with the zone number Bypass reports NOTE: SIA Guidelines: This field must be enabled. UL Exit Error Logic is not suitable for use in a UL installation. 1*20 Exit Delay Reset 0 = disable 1 = enable If enabled, when the panel is armed, the normal exit delay begins. After the user exits, closes the door and then re-enters the premises, the exit delay time is reset to the programmed value. NOTES: Exit Delay Reset is designed to allow an operator to re-enter the premises to retrieve a forgotten item without triggering an alarm. This feature may only be activated once after arming. SIA Guidelines: The Exit Delay must be enabled. UL Exit Delay Reset is not suitable for use in a UL installation. 1*21 Cross-Zoning UL Cross Zoning is not suitable for use in a UL installation. Cross Zoning is designed so that a combination of two zones must be faulted within a 5-minute period of each other (whereas the first zone remains faulted, when the second zone trips) to cause an alarm on either zone. This prevents momentary faults from one of the zones from causing an alarm condition. You can select four "sets" of cross-zones (programmed in data fields 1*22, 1*23, 1*24, and 1*25), keeping in mind the following: • Both zones in each set must protect the same area. • When cross-zoning motion sensors, both device's areas of protection must be situated so that both units will trip at the same time if their shared protected area is violated. • Both zones in each set must be in the same partition. • A fire zone must only be crossed to another fire zone protecting the same physical area (see warning below). DO NOT cross-zone a fire zone with a burglary zone under any circumstance. Cross a fire zone with another fire zone only, and BOTH must be protecting the same physical area (no walls or partitions separating them). Consult NFPA 72 standard for exact spacing requirements. We recommend that spacing between fire cross- zones be no farther than 30 ft. Section 5 – Data Field Descriptions 5-9 Conditions That Affect Cross-Zone Operation • If one of the zones in a pair is bypassed or has a zone response type set to 0, the cross-zoning feature does not apply. • If an entry/exit zone is paired with an interior follower zone, be sure to enter the entry/exit zone as the first zone of the pair. This ensures that the entry delay time is started before the follower zone is processed. • If a relay is programmed to activate on a fault of one of the zones, the relay activates without the other zone being faulted. • If a relay is programmed to activate on either an alarm or trouble, both zones must trip before the relay will activate, and both zones must restore for the relay to deactivate (if relay is programmed to deactivate on a Zone List Restore). If the one of the zones trips and the second zone does not trip within the 5-minute period, an “error” message is reported to the central station. The Contact ID event code is 378. FIELD TITLE and DATA ENTRIES EXPLANATION 1*22 Cross Zoning Pair One Enter 001-250 Enter 000,000 to disable Select the first pair of cross zones, which must both be faulted within a five- minute period to cause an alarm. Must be 000,000 for UL installations. 1*23 Cross Zoning Pair Two Enter 001-250 Enter 000,000 to disable Select the second pair of cross zones, which must both be faulted within a five- minute period to cause an alarm. Must be 000,000 for UL installations. 1*24 Cross Zoning Pair Three Enter 001-250 Enter 000,000 to disable Select the third pair of cross zones, which must both be faulted within a five- minute period to cause an alarm. Must be 000,000 for UL installations. 1*25 Cross Zoning Pair Four Enter 001-250 Enter 000,000 to disable Select the fourth pair of cross zones, which must both be faulted within a five- minute period to cause an alarm. Must be 000,000 for UL installations. 1*26 Panic Button or Speedkey For A, B, C keys: 00 = panic function 01-32 = macro number For D key: 00 = to select a macro to execute when key is pressed 01-32 = macro number Select for the A, B, and C keys whether the system performs a panic or a speedkey function when the key is pressed. Select for the D key whether the system performs a specific macro or if the user will select a macro when the key is pressed. NOTES: If using the A, B, and C, keys for panic alarms, verify fields *22 and *85 are programmed correctly. If a user code with global arm/disarm is used to execute the macro, the user’s global capabilities will override any arm/disarm commands in the macro sequence. 1*28 RF Transmitter Low Battery Sound 0 = disarmed state only 1 = both armed and disarmed states Select when the RF transmitter low-battery condition should display and audible beep annunciate on the keypad. Must be 1 for UL installations. FIELD TITLE and DATA ENTRIES EXPLANATION VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-10 1*29 RF Transmitter Low Battery Reporting 0 = disable 1 = enable If enabled, the system sends a Trouble message for RF transmitter low-battery condition to the central station. NOTE: The Trouble message will be sent for a transmitter supervision failure, independent of this selection. Must be 1 for UL. 1*30 RF Receiver Supervision Check- in Interval Enter 02-15 times 2 hours (4-30 hours). 00 = disable receiver supervision. Select the check-in monitoring interval for the RF receiver(s). Failure of a receiver to receive any RF signal within the time entered results in the activation of the response type programmed for zone 990 for the first receiver and zone 988 for the second receiver and their related communication reports. Maximum is 2 (4 hr) for UL installations. 1*31 RF Transmitter Check-in Interval Enter 02-15 times 2 hours (4-30 hours). 00 = disable transmitter supervision. Select the check-in monitoring interval for the RF transmitters. Failure of an individual transmitter to send a supervision signal within the time entered will result in a trouble response and related communication report. Maximum is 2 (4 hr) for UL. 1*33 TouchTone with Rotary Backup 0 = disable 1 = enable If enabled, the system reverts to rotary dialing if communicator is not successful in dialing using TouchTone DTMF on first attempt. 1*34 Communicator Split Reporting 0 = Split Reporting disabled 1 = Alarm, Alarm Restore, and Cancel reports to primary, all others to secondary 2 = Open/Close and Test reports to secondary, all other reports to primary Select the type of split reporting for system communication. NOTE: See *51 for split/dual reporting combinations. 1*35 Access Control Dialer Enables 0 = disable 1 = enable There are six entries for this field as follows: Trace, Trouble, Not Used, Bypass, System, Alarm. If Trace is enabled, access grant/denial events sent to the central station. For the other events, if enabled, a report is sent to the central station. 1*42 Call Waiting Defeat 0 = disable 1 = enable If enabled, the system defeats Call Waiting on the first outgoing call attempt to both the primary and secondary numbers. NOTES: After the panel's initial call to report the alarm, the panel may attempt to make an additional call, perhaps for a cancel or a zone restoral. If Call Waiting is not defeated, an operator at the central station attempting to contact the premises (to verify whether the alarm is valid) hears the phone ringing indefinitely and must to dispatch on the call. DO NOT enable this feature unless Call Waiting is being used. 1*43 Permanent Keypad Display Backlighting (partition-specific) 0 = disable 1 = enable If enabled, backlighting for the keypad display remains on at all times. Otherwise the backlighting comes on when a key is pressed. NOTE: When a key is pressed, display backlighting turns on for all keypads in that partition. 1*44 Wireless Keypad Tamper Detect 0 = disable 1 = enable If enabled, when more than 40 key depressions are received without a valid sequence (arm, disarm, etc.), the control panel disables the wireless keypad. The inhibit is removed once a valid key sequence is received from a wired keypad. FIELD TITLE and DATA ENTRIES EXPLANATION Section 5 – Data Field Descriptions 5-11 1*45 Exit Delay Sounding (partition- specific) 0 = disable 1 = enable If enabled, the system produces slow beeping from the keypads during exit delay and reverts to rapid beeping during the last 10 seconds of the exit delay. NOTE: The duration of the beeping is the programmed value of field *10 regardless of which entry/exit zone is used to exit the premises. SIA Guidelines: Exit Delay Sounding must be enabled. See page 32 in the Programming Guide, “SOUND OPTION”, prompt for disabling the entry/exit beeps on individual keypads. 1*46 Auxiliary Output Mode 0 = ground start output. 1 = smoke detector reset. 2 = keypad sounds at an auxiliary sounder. 3 = AAV module. Select the mode for output 1 on the J7 triggers. NOTES: Only one of the options may be active within the system. Option 2 is available in the VISTA-128BP only. Option 2 applies only to the partition enabled in field *15. 1*47 Chime on External Siren (partition-specific) 0 = disable 1 = enable If enabled, the system produces chime annunciation on the external alarm sounder. 1*48 Wireless Keypad Assignment 0 = none 1-8 = partition number Select the partition in which RF keypad is used. 1*49 Suppress Transmitter Supervision Sound 0 = disable 1 = enable If enabled, no trouble soundings occur on the keypad for transmitter check-in failures. Must be 0 for UL. 1*52 Send Cancel If Alarm + Off (partition-specific) 0 = disable 1 = enable If enabled, Cancel reports are sent when the system is disarmed after an alarm, regardless of how much time has gone by. If disabled, Cancel reports are sent within Bell Timeout period only. NOTE: This option must be enabled so Cancel reports are always sent. 1*53 Disable Download Callback 0 = callback required 1 = no callback required Select whether a callback from the control panel is required for downloading. Must be 0 for UL installations. 1*55 European Date Format 0 = disable (mm/dd/yy) 1 = enable (dd/mm/yy) Select the date format for display in the event log. 1*56 AC 60Hz or 50Hz 0 = 60Hz 1 = 50Hz Select the frequency for the AC. Must be set to 0 for U.S. and Canadian installations. 1*57 Enable 5800 RF Button Global Arm 0 = disable 1 = enable If enabled, the system arms/disarms in accordance with the button’s user’s global arming settings. 1*58 Enable 5800 RF Button Force Arm 0 = disable 1 = enable If enabled, allows the RF button user to force a bypass of all faulted zones when arming the system. NOTE: When attempting to arm the system, the keypad beeps once after the button is pressed if any faulted zones are present. The user should then press the button again within 4 seconds to force-bypass those zones and arm the system. FIELD TITLE and DATA ENTRIES EXPLANATION VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-12 1*60 Zone 5 Audio Alarm Verification 0 = disable 1 = enable If enabled, zone 5 is used for 2-way audio (AAV). Must be 0 for UL installations. NOTE: Zone 5 cannot be used as protection zone. 1*69 Printer Type 0 = parallel printer 1 = serial printer Select the printer type for the event log printout. NOTE: if you are using a parallel printer connected to the VA8201 Alpha Pager Module. 1*70 Event Log Types 0 = disable 1 = enable This field has five entries as follows: Alarm, Check, Bypass, Open/Close, System. If enabled, the system logs those events into the event log. NOTE: Events are also logged into the PassPoint system, if installed. 1*71 12/24 Hour Type Stamp Format 0 = 12-hour 1 = 24-hour Select the type of time stamping for the event log. 1*72 Event Log Printer On-Line Mode 0 = disable 1 = enable If enabled, the system prints the events as they occur. If disabled, the system prints the log only upon request. 1*73 Printer Baud Rate 0 = 1200 1 = 300 Select the baud rate for the serial printer. NOTE: Must be 1 if using the alphanumeric pager interface. 1*74 Relay Timeout XXX Minutes Enter 000-127 times 2 minutes (000-254). This is used for #80 Menu Mode Time-Driven event relay command numbers “04/09” and Output Programming in the #93 Menu Mode Programming output command “56.” 1*75 Relay Timeout YYY Seconds Enter 000-127 seconds. This is used for #80 Menu Mode Time-Driven event relay command numbers “05/10” and Output Programming in the #93 Menu Mode Programming command “57.” 1*76 Access Control Relay (partition- specific) 01-96 = relay number 00 = relay not used. If enabled, the assigned relay closes for 2 seconds when the user enters his code and presses 0. Must be 00 for UL installations. NOTE: See SECTION 3: Installing the Control for enhanced access control capabilities. 2*00 Number of Partitions Enter 1-8. Enter the number of partitions used in the system. 2*01 Daylight Saving Time Start/End Month 0 = disable 1 = enable Enter the months (00-12) in which daylight saving time starts and ends. Enter 00, 00 if daylight saving time does not apply to the user’s region. Standard setting for U.S. is 04,10. 2*02 Daylight Saving Time Start/End Weekend 0 = disable 1 = enable Enter the start and end weekends for daylight saving time as follows: 1=first; 2=second; 3=third; 4=fourth; 5=last; 6=next to last; 7=third from last. Standard setting for U.S. is 1,5. UL Fields 2*05 – 2*08 must be set to 0 for UL installations. FIELD TITLE and DATA ENTRIES EXPLANATION Section 5 – Data Field Descriptions 5-13 2*05 Auto-Arm Delay (partition- specific) 00 = no delay. 01-14 times 4 minutes (04-56) delay. 15 = no auto arming. This is the time between the end of the arming window and the start of auto-arm warning time (field 2*06). 2*06 Auto-Arm Warning Period (partition-specific) 01-15 times 1-minute warning. 00 = no warning period. This is the time that the user is warned by a keypad sounding and display to exit the premises prior to auto arming of the system. 2*07 Auto-Disarm Delay (partition- specific) 00 = no delay. 01-14 times 4 minutes (04-56) delay. 15 = no auto disarming. This is the time between the end of the disarming window and the start of auto disarming of the system. 2*08 Force Arm Enable for Auto-Arm (partition-specific) 0 = disable 1 = enable If enabled, the system automatically bypasses any faulted zones when it attempts to auto-arm. If disabled, the system will not auto-arm. 2*09 Open/Close Reports by Exception (partition-specific) 0 = disable 1 = enable If enabled, Open/Close reports are sent only if the openings/closings occur outside the arm and disarm windows. NOTES: Open reports are also suppressed during the closing window in order to prevent false alarms if the user arms the system, then re-enters the premises, for example to retrieve a forgotten item. Openings and closings are still recorded in the event log. This field must be set to 1 if No Opening and No Closing reports are to be sent. 2*10 Allow Disarming Only During Arm/Disarm Windows (partition- specific) 0 = disable 1 = enable If enabled, disarming of the system is allowed only during the arming/disarming windows, or if the system is in alarm (if 2*11 is set to 1). NOTE: This applies only to Operator-level users. Installer, Master, and Manager-level users can disarm the system at any time. 2*11 Allow Disarm Outside Window if Alarm Occurs 0 = disable 1 = enable If enabled, allows the system to be disarmed outside the programmed disarm (opening) window if an alarm has occurred. Otherwise disarming is allowed only during the disarm window. NOTE: Used only if field 2*10 is enabled. 2*18 Enable GOTO for this Partition (partition-specific) 0 = disable 1 = enable If enabled, this partition can be accessed from another partition’s keypad using the GOTO command. 2*19 Use Partition Descriptor 0 = disable 1 = enable If enabled, the normal keypad display will include a partition number and four- digit descriptor. 2*20 Enable J7 Triggers for Partition (partition-specific) 0 = disable 1 = enable If enabled, the J7 triggers function for this partition. FIELD TITLE and DATA ENTRIES EXPLANATION VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-14 2*21 Supervision Pulses for LRR 0 = disable 1 = enable There are three entries in this field as follows: Fire, Burglary/Audible Panic, Silent Panic/Duress. If enabled, causes the control to send periodic short pulses on the J7 radio triggers to the LRR. The LRR uses these pulses to determine that its connection to the control is still intact. Must be 1 for UL installations. 2*22 Display Fire Alarms of Other Partitions (partition-specific) 0 = disable 1 = enable If enabled, allows fire alarms that occur on other partitions to be displayed at this partition’s keypad(s). 2*23 Display Burglary & Panic Alarms for Other Partitions (partition- specific) 0 = disable 1 = enable If enabled, allows burglary and panic alarms that occur on other partitions to be displayed at this partition’s keypad(s). 2*24 Display Troubles of Other Partitions (partition-specific) 0 = disable 1 = enable If enabled, allows troubles that occur on other partitions to be displayed at this partition’s keypad(s). 2*30 Pager Installed 0 = disable 1 = enable Enable if the alphanumeric pager interface is installed. 2*31 Delay Paging 0 = disable 1 = enable This field has eight locations, one for each pager. If enabled, the system waits the delay time specified in field 2*32 before transmitting the message after the dialer completes sending the message. 2*32 Time to Delay Pager After Dialer 000-024 times 10 seconds (010-240). This delay should be set to allow enough time for the central station to call back the premises in order to verify an alarm condition. Field 2*31 must be enabled. 2*33 Pager 1 Phone Number Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause. Enter the paging service phone number for Pager 1. Enter up to 17 digits. Do not fill unused spaces. 2*34 Pager 1 ID Number Enter 0-9 Enter the Pager ID number for Pager 1. Enter up to 10 digits. 2*35 Pager 1 Format 0 = numeric 1 = ID 2 = alphanumeric Enter the pager format for Pager 1. 2*36 Pager 1 Delay 1 000-060 seconds. This delay occurs after the phone number is dialed and before the pager ID is sent, giving the pager system time to answer the phone call. NOTE: Program only if using numeric format. 2*37 Pager 1 Delay 2 000-060 seconds. This delay occurs after the pager ID is sent and before the event information is sent. NOTE: Program only if using numeric format. FIELD TITLE and DATA ENTRIES EXPLANATION Section 5 – Data Field Descriptions 5-15 2*38 Pager 1 Partition Enable 0 = disable 1 = enable This field has eight entries, one for each partition. If enabled, the system sends messages to Pager 1 for the partition(s). 2*39 Pager 1 Trigger Event Enables 0 = disable 1 = enable This field has five entries as follows: Alarm, Trouble, Bypass, Open/Close, System. If enabled, the system sends a signal to the pager. 2*40 Pager 2 Phone Number Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause. Enter the paging service phone number for Pager 2. Enter up to 17 digits. Do not fill unused spaces. 2*41 Pager 2 ID Number Enter 0-9 Enter the Pager ID number for Pager 2. Enter up to 10 digits. 2*42 Pager 2 Format 0 = numeric 1 = ID 2 = alphanumeric Enter the pager format for Pager 2. 2*43 Pager 2 Delay 1 000-060 seconds. This delay occurs after the phone number is dialed and before the pager ID is sent, giving the pager system time to answer the phone call. NOTE: Program only if using numeric format. 2*44 Pager 2 Delay 2 000-060 seconds. This delay occurs after the pager ID is sent and before the event information is sent. NOTE: Program only if using numeric format. 2*45 Pager 2 Partition Enable 0 = disable 1 = enable This field has eight entries, one for each partition. If enabled, the system sends messages to Pager 2 for the partition(s). 2*46 Pager 2 Trigger Event Enables 0 = disable 1 = enable This field has five entries as follows: Alarm, Trouble, Bypass, Open/Close, System. If enabled, the system sends a signal to the pager. 2*47 Pager 3 Phone Number Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause. Enter the paging service phone number for Pager 3. Enter up to 17 digits. Do not fill unused spaces. 2*48 Pager 3 ID Number Enter 0-9 Enter the Pager ID number for Pager 3. Enter up to 10 digits. 2*49 Pager 3 Format 0 = numeric 1 = ID 2 = alphanumeric Enter the pager format for Pager 3. 2*50 Pager 3 Delay 1 000-060 seconds. This delay occurs after the phone number is dialed and before the pager ID is sent, giving the pager system time to answer the phone call. NOTE: Program only if using numeric format. 2*51 Pager 3 Delay 2 000-060 seconds. This delay occurs after the pager ID is sent and before the event information is sent. NOTE: Program only if using numeric format. FIELD TITLE and DATA ENTRIES EXPLANATION VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-16 2*52 Pager 3 Partition Enable 0 = disable 1 = enable This field has eight entries, one for each partition. If enabled, the system sends messages to Pager 3 for the partition(s). 2*53 Pager 3 Trigger Event Enables 0 = disable 1 = enable This field has five entries as follows: Alarm, Trouble, Bypass, Open/Close, System. If enabled, the system sends a signal to the pager. 2*54 Pager 4 Phone Number Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause. Enter the paging service phone number for Pager 4. Enter up to 17 digits. Do not fill unused spaces. 2*55 Pager 4 ID Number Enter 0-9 Enter the Pager ID number for Pager 4. Enter up to 10 digits. 2*56 Pager 4 Format 0 = numeric 1 = ID 2 = alphanumeric Enter the pager format for Pager 4. 2*57 Pager 4 Delay 1 000-060 seconds. This delay occurs after the phone number is dialed and before the pager ID is sent, giving the pager system time to answer the phone call. NOTE: Program only if using numeric format. 2*58 Pager 4 Delay 2 000-060 seconds. This delay occurs after the pager ID is sent and before the event information is sent. NOTE: Program only if using numeric format. 2*59 Pager 4 Partition Enable 0 = disable 1 = enable This field has eight entries, one for each partition. If enabled, the system sends messages to Pager 4 for the partition(s). 2*60 Pager 4 Trigger Event Enables 0 = disable 1 = enable This field has five entries as follows: Alarm, Trouble, Bypass, Open/Close, System. If enabled, the system sends a signal to the pager. 2*61 Pager 5 Phone Number Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause. Enter the paging service phone number for Pager 5. Enter up to 17 digits. Do not fill unused spaces. 2*62 Pager 5 ID Number Enter 0-9 Enter the Pager ID number for Pager 5. Enter up to 10 digits. 2*63 Pager 5 Format 0 = numeric 1 = ID 2 = alphanumeric Enter the pager format for Pager 5. 2*64 Pager 5 Delay 1 000-060 seconds. This delay occurs after the phone number is dialed and before the pager ID is sent, giving the pager system time to answer the phone call. NOTE: Program only if using numeric format. 2*65 Pager 5 Delay 2 000-060 seconds. This delay occurs after the pager ID is sent and before the event information is sent. NOTE: Program only if using numeric format. FIELD TITLE and DATA ENTRIES EXPLANATION Section 5 – Data Field Descriptions 5-17 2*66 Pager 5 Partition Enable 0 = disable 1 = enable This field has eight entries, one for each partition. If enabled, the system sends messages to Pager 5 for the partition(s). 2*67 Pager 5 Trigger Event Enables 0 = disable 1 = enable This field has five entries as follows: Alarm, Trouble, Bypass, Open/Close, System. If enabled, the system sends a signal to the pager. 2*68 Pager 6 Phone Number Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause. Enter the paging service phone number for Pager 6. Enter up to 17 digits. Do not fill unused spaces. 2*69 Pager 6 ID Number Enter 0-9 Enter the Pager ID number for Pager 6. Enter up to 10 digits. 2*70 Pager 6 Format 0 = numeric 1 = ID 2 = alphanumeric Enter the pager format for Pager 6. 2*71 Pager 6 Delay 1 000-060 seconds. This delay occurs after the phone number is dialed and before the pager ID is sent, giving the pager system time to answer the phone call. NOTE: Program only if using numeric format. 2*72 Pager 6 Delay 2 000-060 seconds. This delay occurs after the pager ID is sent and before the event information is sent. NOTE: Program only if using numeric format. 2*73 Pager 6 Partition Enable 0 = disable 1 = enable This field has eight entries, one for each partition. If enabled, the system sends messages to Pager 6 for the partition(s). 2*74 Pager 6 Trigger Event Enables 0 = disable 1 = enable This field has five entries as follows: Alarm, Trouble, Bypass, Open/Close, System. If enabled, the system sends a signal to the pager. 2*75 Pager 7 Phone Number Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause. Enter the paging service phone number for Pager 7. Enter up to 17 digits. Do not fill unused spaces. 2*76 Pager 7 ID Number Enter 0-9 Enter the Pager ID number for Pager 7. Enter up to 10 digits. 2*77 Pager 7 Format 0 = numeric 1 = ID 2 = alphanumeric Enter the pager format for Pager 7. 2*78 Pager 7 Delay 1 000-060 seconds. This delay occurs after the phone number is dialed and before the pager ID is sent, giving the pager system time to answer the phone call. NOTE: Program only if using numeric format. 2*79 Pager 7 Delay 2 000-060 seconds. This delay occurs after the pager ID is sent and before the event information is sent. NOTE: Program only if using numeric format. 2*80 Pager 7 Partition Enable 0 = disable 1 = enable This field has eight entries, one for each partition. If enabled, the system sends messages to Pager 7 for the partition(s). FIELD TITLE and DATA ENTRIES EXPLANATION VISTA-128BP/VISTA-250BP Installation and Setup Guide 5-18 2*81 Pager 7 Trigger Event Enables 0 = disable 1 = enable This field has five entries as follows: Alarm, Trouble, Bypass, Open/Close, System. If enabled, the system sends a signal to the pager. 2*82 Pager 8 Phone Number Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause. Enter the paging service phone number for Pager 8. Enter up to 17 digits. Do not fill unused spaces. 2*83 Pager 8 ID Number Enter 0-9 Enter the Pager ID number for Pager 8. Enter up to 10 digits. 2*84 Pager 8 Format 0 = numeric 1 = ID 2 = alphanumeric Enter the pager format for Pager 8. 2*85 Pager 8 Delay 1 000-060 seconds. This delay occurs after the phone number is dialed and before the pager ID is sent, giving the pager system time to answer the phone call. NOTE: Program only if using numeric format. 2*86 Pager 8 Delay 2 000-060 seconds. This delay occurs after the pager ID is sent and before the event information is sent. NOTE: Program only if using numeric format. 2*87 Pager 8 Partition Enable 0 = disable 1 = enable This field has eight entries, one for each partition. If enabled, the system sends messages to Pager 8 for the partition(s). 2*88 Pager 8 Trigger Event Enables 0 = disable 1 = enable This field has five entries as follows: Alarm, Trouble, Bypass, Open/Close, System. If enabled, the system sends a signal to the pager. 6-1 SECTION 6 Scheduling Options •••••••••••••••••••••••••••••••••••••••••••••••• • UL • You must program Bypass and Auto-Arm Fail reports for UL installations. • Auto-disarming is not permitted in UL installations. • You must not program Random Scheduling of Time Driven Events for UL installations. General The scheduling features allow certain operations to be automated, such as arming, disarming, bypassing of zones, and activating relay outputs. The system uses time windows (a programmed period of time with a start and stop time) for defining open/close schedules, holiday schedules, user-defined temporary schedules, and access schedules for users. Scheduled events are programmed by user-friendly menu modes of programming (#80, #81, #83, and #93 modes), explained in detail in this section. These menus take you step by step through the options. Auto Arming The system can automatically arm (AWAY Mode) a partition at the end of a pre-determined closing (arming) time window. Auto Arming can be delayed three ways: by use of the Auto-Arm Delay, the Auto-Arm Warning, or by manually extending the closing (arming) time window with a keypad command. The system can also automatically bypass any open zones when auto arming. Auto-Arm Delay Auto-Arm Delay provides a delay (grace period) before auto arming. It starts at the end of the closing time window. The delay is set in 4-minute increments, up to 56 minutes in partition-specific program field 2*05. At the expiration of this delay, the Auto-Arm Warning will start. Auto-Arm Warning The Auto-Arm Warning causes the keypad sounder to warn the user of an impending Auto-Arm. The warning can be set from 1 to 15 minutes prior to the arming in partition-specific program field 2*06. During this period the keypad beeps every 15 seconds and displays “AUTO ARM ALERT.” During the last 60 seconds, the keypads beep every 5 seconds. The panel arms at the conclusion of the Auto-Arm Warning period. Extend Closing Window A user can manually delay the arm (closing) time window by 1 or 2 hours. This is done by entering a keypad command (User Code + #82), which then prompts the user to enter the desired extension time of 1 or 2. This feature is useful if a user must stay on the premises later than usual. The Auto-Arm delay and warning periods begin at the end of the extension. Force Arm The Force Arm option causes the panel to attempt to bypass any faulted zones prior to auto arming (panel performs a force-arm). This option is set in partition-specific program field 2*08. Auto Disarming The system can automatically disarm a partition at the end of a pre-determined opening (disarm) time window. The disarming time can be delayed by using the Auto- Disarm Delay feature. Disarm Delay Auto-Disarm Delay provides a delay before auto disarming. This delay is added to the end of the disarm time window. The delay is set in 4-minute increments, up to 56 minutes, in partition-specific program field 2*07. Restrict Disarming This option allows disarming by users only during the disarm time window and during the arming time window (in case user needs to re-enter premises after manually arming the partition). This option is set in partition-specific field 2*10. If field 2*10 is set, we highly recommend setting field 2*11, as well. This field allows the partition to be disarmed outside the arm/disarm time windows only if the partition is in alarm. VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-2 Exception Reports This option allows the reporting of openings and closings to the central station only if the arming and disarming occurs outside of the predetermined opening and closing time windows. It is set in partition-specific field 2*09. The system can be programmed to send Failed to Open and Failed to Close reports if the partition is not armed or disarmed by the end of the corresponding time window. Limitation of Access of Users by Time A user’s access to the system can be limited to a certain time period. Outside this time, that user’s code is inactive. The system provides up to 8 access schedules, each consisting of two time windows (typically one for opening, one for closing) for each day of the week and two time windows for holidays. The access schedules are programmed in the #80 Menu Mode, and enabled when a user’s access code is added to the system. If a user tries to operate the system outside the schedule, the alpha keypad displays “Access Denied.” Time-Driven Events The system can automatically activate and de-activate relays at predetermined times to turn lights or other devices on and off. The Time-Driven events can be activated at different times in relation to a time window: • At the beginning of a time window • At the end of a time window • During a time window (on at beginning of window, off at end) • At both the beginning and end of the time window (e.g., to sound a buzzer at the beginning and end of a coffee break) • Random time at the start of the time window (occurs within 30 minutes after the start of the time window) • Random time at the end of the time window (occurs within 30 minutes after the end of the time window) • Random during the time window (begins within 30 minutes after the start of the time window and ends within 30 minutes after the end of the time window) The system can perform the same actions on a daily basis, or can perform an action only once (e.g., turn on the porch light this Wednesday at 8:00 PM). The system also provides up to 20 programmable “timers” available to the end user for the purpose of activating output devices at preset times and days. Time Window Definitions Scheduled events are based on time windows, (periods of time) during which an event may take place. The system supports up to 20 time windows, each defined by a “Start” time and a “Stop” time. The windows are shared by all 8 partitions, and are used when programming the various schedules (open/close, limitation of access), as well as for Time- Driven event control. Scheduling Example A store that has the following hours: Monday to Friday 9am to 6pm Saturday 10am to 4pm Sunday Closed Holidays Closed The owner desires the following time windows to allow time for employees to arm or disarm the system: Monday to Friday Open (disarm) 8am to 9am Close (arm) 6pm to 6:30pm Saturday Open (disarm) 9am to 10am Close (arm) 4pm to 4:30pm Sunday & Holidays Closed For this schedule, the four time windows need to be programmed: Window Start Stop Purpose 1 8am 9am Monday-Friday open window 2 9am 10am Saturday open window 3 4pm 4:30pm Saturday close window 4 6pm 6:30pm Monday-Fri. close window Using the #80 Menu Mode, the installer can program open/close schedules by assigning a time window to a day of the week (windows are entered as 2-digit entries) Mon Tue Wed Thu Fri Sat Sun Hol Op/Cl Op/Cl Op/Cl Op/Cl Op/Cl Op/Cl Op/Cl Op/Cl 01/04 01/04 01/04 01/04 01/05 02/03 00/00 00/00 NOTE: 00 is entered for those days on which the store is closed. Employees can arm and disarm the system, when programmed, within the open and close time windows without causing a report to be sent to the central VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-2 station (reporting by exception, field 2*09). The system can be programmed to automatically arm/disarm in case an employee fails to arm/disarm manually (auto-arm/auto-disarm). Open/Close Schedules Definitions General The open/close scheduling is controlled by one of three schedules. Each schedule consists of one time window for openings and one time window for closings. There are three types of schedules available: Daily, Holiday, and Temporary. Daily Schedule Each partition can have one daily schedule consisting of one opening window and one closing window per day. Holiday Schedule A holiday schedule overrides the regular daily schedule on selected holidays throughout the year. The opening and closing windows are programmed in the daily schedule, but the holidays themselves are defined in Holiday Schedule Programming in the #80 Menu Mode. Temporary Schedule The temporary schedule provides a method for the end user to override the daily and holiday schedules. It consists of one opening window and one closing window for each day of the week. The schedule takes effect for up to one week, after which it is automatically deactivated. This schedule is programmed using the #81 Temporary Schedule Menu Mode. Additional Schedules Additional opening and closing schedules can be programmed using the Time-Driven Event Programming. For example, a schedule for normal store openings/closings can be programmed with a daily open/close schedule, and another open/close schedule for a lunch hour can be programmed using the Time-Driven event schedule programming. Refer to “Time-Driven Events” later in this section for detailed information. Open/Close Reports by Exception The system can help reduce communication traffic to the central station by using the Open/Close Reports by Exception feature. The Open/Close by Exception option suppresses these reports from being sent to the central station if an arm or disarm is done within the expected time window. Reports are only sent if the arm or disarm occurs outside the assigned time window. The system keeps a record of all openings/closings in its event log. If a disarming occurs during a closing window (for example, a person who arms the system forgets something and has to re-enter), the Opening report (although outside of the opening window) will not be sent (as long as that disarming occurs within the closing window). This option is programmed in partition-specific program field 2*09. Example of Open/Close Exception Reporting & Scheduling The following chart gives an example of how the Open/Close by Exception reporting works. 6:01PM 5:59AM 6AM 9AM 9:01AM 3:59PM 4PM 6PM 6:01PM 5:59AM Early Opening reports are sent if system is manually disarmed before opening window begins. Early and Late Opening and Closing reports are programmable options in the Report Code Programming. They are not dependent on the programming of the Exception Reporting option. Opening Window No reports are sent if system is disarmed during this time window. If an arming occurs, a Closing report is sent to the central station regardless of how the Exception Reporting option is set. Auto-disarm delay begins. Auto-disarm occurs after delay (if auto-disarm is enabled). Missed Opening reports are sent if manual disarming has not occurred at expiration of opening window. Late Opening reports are sent if disarm occurs after the opening window expires. Early Closing reports are sent if manual arming occurs before the closing window begins. Missed Opening/Closing type reports are programmed in the Report Code Programming. The Exception Reporting option must be set for these to be sent. Closing Window No reports are sent if system is armed* during this time window. * or disarmed if user needs to re-enter premises. Auto-arm delay begins. Auto-arm warning begins. Auto-arm occurs after warning expires (if auto-arm is enabled). Missed Closing reports are sent if manual arming has not occurred at expiration of closing window. Late Closing reports are sent if system is manually armed after the closing window expires. VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-4 Scheduling Menu Mode The #80 Scheduling Menu Mode is used to program most of the scheduling and timed-event options. Enter Installer Code + [#] + [8] + [0] from the normal operating mode. NOTE: Only users with an Installer or Master level user code may enter the #80 mode. The following can be programmed while in this mode: • time windows • open/close schedules to each partition • holiday schedules • Time-Driven events (for system functions and relay activation) • limitation of access schedules Some scheduling features are programmed in Data Field Programming Mode (Installer Code + 8 0 0 0). Some features are programmed in the #93 Menu Mode. The programming scheduling fields are listed below. System-Wide Fields: *04 Enable Random Timers 1*74 –1*75 Relay timeout values 2*01-2*02 Daylight saving time options 2*11 Allow disarming outside window if alarm occurs Partition-Specific fields: 2*05 Auto-arm delay value 2*06 Auto-arm warning time 2*07 Auto-disarm delay value 2*08 Force-arm enable 2*09 Open/Close Reporting by Exception 2*10 Restrict disarm only during windows #93 Menu Mode (System Group #3) Scheduling related report codes Event-driven options are programmed using Output Programming in #93 Menu Mode. Relay activation can also be Time-Driven and that those are programmed using the #80 Menu Mode. Refer to the Time-Driven Event Programming later in this section for the procedure. Steps to Program Scheduling Options This section contains examples of the worksheets only. For complete worksheets, see the Programming Guide accompanying this Installation and Setup Guide. In order to use #80 Scheduling Menu Mode, use the worksheets to do the following: 1. Define time windows (up to 20) 2. Define the daily open/close schedules (one schedule per day, per partition) 3. Define the holidays to be used by the system (up to 16) 4. Define limitation of access times (up to 8 schedules) 5. Define the Time-Driven events (up to 20) NOTE: Temporary schedules are programmed using #81 Menu Mode. Use #80 Scheduling Menu Mode to perform the following functions: 6. Program the time windows 7. Program the open/close schedules 8. Program the Time-Driven events 9. Program the access schedules Scheduling Menu Structure To program schedules, enter Scheduling Program Mode: Installer Code + [#] + [80]. (Installer or Master level user code.) Scheduling Program Mode can be entered only when all partitions are disarmed. There are 6 sections of scheduling menus accessed via #80, as shown below. Entering 1 at a displayed main menu prompt selects that menu section. Prompts for programming that scheduling feature then appear. Enter 0 to skip a section and display the next menu option. PROMPT EXPLANATION Time Window ? 1 = YES 0 = NO 0 Upon entering Schedule Menu Mode, this prompt appears. Enter 1 to program time windows. Refer to Time Windows Programming later in this section for detailed procedures. Enter 0 to move to the “O/C Schedules?” prompt. O/C Schedules ? 1 = YES 0 = NO 0 Enter 1 to program opening and closing schedules. Refer to Open/Close Schedules Programming later in this section for detailed procedures. Enter 0 to move to the “Holidays?” prompt. Section 6 – Scheduling Options 6-5 Holidays ? 1 = YES 0 = NO 0 Enter 1 to program holiday schedules. Refer to Holiday Schedule Programming later in this section for detailed procedures. Enter 0 to move to the “Timed Events?” prompt. PROMPT EXPLANATION Timed Events ? 1 = YES 0 = NO 0 Enter 1 to program timed events for relay outputs, additional schedules, and other system functions. Refer to Time-Driven Event Programming later in this section for detailed procedures. Enter 0 to move to the “Access Sched?” prompt. Access Sched. ? 1 = YES 0 = NO 0 Enter 1 to program access schedules. Refer to Limitation of Access Schedules Programming later in this section for detailed procedures. Enter 0 to move to the “Quit?” prompt. Quit ? 1 = YES 0 = NO 0 Enter 1 to quit #80 Scheduling Menu Mode and return to normal operating mode. Enter 0 to make any changes or review the scheduling programming options. If you press 0, the “Time Window?” prompt is displayed. Time Windows The system provides 20 time windows that are defined with start and stop times. These windows are used for various open/close and access schedules, as well as for output controls, and are the basis of the scheduling system. These windows are shared among all 8 partitions. Time Windows Worksheet The following worksheet is an example of the worksheet found in the Programming Guide. This worksheet will help you define time windows and scheduling aspects of this system before you program them. Note that time windows can span midnight; for example, from 11 PM to 1 AM. Time Window Number Start Time (HH:MM) Stop Time (HH:MM) 1 2 3…..20 A time window must have a start and a stop time. Time Windows Programming Enter Scheduling Mode by entering Installer Code + [#] + [80]. The keypad displays the Time Window Programming prompt. PROMPT EXPLANATION Time Window ? 1 = YES 0 = NO 0 Enter 1 at this main menu prompt to program time windows. Time Window # ? 01-20, 00 = Quit 01 Enter the 2-digit time window number (01-20) to be programmed. Press [✳] to accept the entry. Enter 00 + [✳] at the “Time Window #?” prompt to quit time window programming and display the “Quit ?” prompt. 01 TIME WINDOW 00:00AM 00:00AM If you entered a time window number, the cursor is now positioned on the tens of hours digit of the start of window entry. Enter the desired start of window hour and press [✳]. The cursor moves to the minutes position. Enter the desired minutes and press [✳]. Toggle the AM/PM indication by pressing any key 0-9 while the cursor is under the A/P position and then press [✳]. Repeat this to program the stop of window entry. When the entry is completed, the “Time Window #?” prompt is displayed again. Enter the next time window number to be programmed and repeat the procedure. Quit ? 1 = YES 0 = NO 0 Enter 0 at the Quit ? prompt to return to the main menu choices and continue programming. Enter 1 to quit Scheduling Menu Mode. VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-2 Because the time windows are shared among all partitions, it is important to make sure that changing a time window does not adversely affect desired actions in other partitions. Daily Open/Close Schedules Each partition can be assigned one daily open/close schedule, plus a holiday schedule. Temporary schedules are programmed separately, using the #81 Temporary Schedule Menu Mode. To program additional open/close schedules, see Time-Driven Events Programming later in this section for the procedure. Open/Close Schedule Worksheet The following worksheet is an example of the worksheet found in the Programming Guide. Write the previously defined time window numbers for open and close for each partition. Part Mon Tues Wed Thur Fri Sat Sun Hol Op Cl Op Cl Op Cl Op Cl Op Cl Op Cl Op Cl Op Cl 1 2 3…8 Open/Close Schedule Programming After entering Scheduling Menu Mode, press [0] until the “O/C Schedules?” prompt appears. PROMPT EXPLANATION O/C Schedules ? 1 = YES 0 = NO 0 Enter 1 to program opening and closing schedules. Partition # ? 01-08, 00 = Quit 01 Enter the appropriate partition number for which the following open/close schedules will apply. Enter 00 + [✳] at the “Partition #?” prompt to quit open/close schedules programming and display the “Quit ?” prompt. Mon P1 OP WIND.? 00:00 00:00 00 Enter the time window number 01-20 for the displayed day’s opening schedule beginning with Monday. Enter 00 if no schedule is desired for a particular day. As the number is keyed in, the actual time that has been stored for that window number is displayed as a programming aid. Press [✳] to accept the entry. Mon P1 CL WIND.? 00:00 00:00 00 Enter the time window number for the displayed day’s closing schedule. As the number is keyed in, the actual time that has been stored for the window number is displayed. Press the [✳] key to accept the entry. Tue P1 OP WIND.? 00:00 00:00 00 The keypad now prompts for Tuesday’s open/close schedule. Follow the procedure for Monday’s prompts. When the last day of the week has been programmed, the holiday opening and closing window prompts are displayed. Hol P1 OP WIND.? 00:00 00:00 00 Repeat the procedure for the holiday opening and closing time windows. Press the [✳] key to accept the entry. When the entries are completed, the “Partition #?” prompt is displayed again. Repeat this procedure for each partition in the system. Quit ? 1 = YES 0 = NO 0 Enter 0 at the “Quit ?” prompt to return to the main menu choices and continue programming. Enter 1 to quit Scheduling Menu Mode. 6-1 Holiday Schedules A holiday schedule overrides the regular daily open/close schedule on the programmed holidays throughout the year. The system provides up to 16 holidays that can be assigned for the system. Each holiday can be assigned to any combination of partitions. List the desired holidays in a Month/Day format on the worksheet. Check the partitions for which these holidays apply. Holiday Schedule Worksheet The following worksheet is an example of the worksheet found in the Programming Guide. HOL Partition Month/Day 1 2 3 4 5 6 7 8 1 / 2 / 3…16 Holiday Schedule Programming After entering Scheduling Menu Mode, press [0] until the “Holidays ?” prompt appears. PROMPT EXPLANATION Holidays ? 1 = YES 0 = NO 0 Enter 1 to program holiday schedules. HOLIDAY NUMBER ? 01-16,00=Quit 01 Enter the 2-digit holiday number (01-16) to be programmed and press [✳] to accept entry. Enter 00 + [✳] at the “Holiday Number?” prompt to quit the holiday menus and display the “Quit ?” prompt. 01 ENTER DATE 00/00 The cursor is now positioned on the tens of months digit. Enter the appropriate month, then press [✳] to proceed to the day field. Enter the appropriate day for the holiday. Press [✳] to accept the entry. Part ? 12345678 Hit 0-8 x x Holidays can be set for any partition, as follows. Press [0] to turn all partitions on or off, or use keys 1-8 to toggle the letter “x” under the partition to which this holiday will apply. Press the [✳] key when all desired partitions have been assigned. The “Holiday Number?” prompt is displayed again. Repeat the procedure for each holiday to be programmed. Quit ? 1 = YES 0 = NO 0 Enter 0 at the “Quit ?” prompt to return to the main menu choices and continue programming. Enter 1 to quit Scheduling Menu Mode. Time-Driven Events These schedules are used to activate outputs, bypass zones, etc. based on time. There are 20 of these schedules that may be programmed for the system, each governed by the previously defined time windows. The actions that can be programmed to automatically activate at set times are: relay commands, arm/disarm commands, zone bypassing commands, and open/close access conditions. Time-Driven Events Worksheet The following worksheet is an example of the worksheet found in the Programming Guide. Fill out the worksheet using the steps outlined below. Automatic Refresh Feature The system automatically updates the status of all Time-Driven Events upon any of the following occurrences: • Changing of the time or date via #63 mode • Exiting #80 Scheduling Menu mode • Exiting Program mode • After a disconnect from the downloader • On a power-up • At Daylight Saving Time adjustment. Sched Time Days Action Action Activation VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-2 Num. Window M T W T F S S HDesired Specifier Time 1 2 3…20 1. Enter the schedule number (01-20) and time window number (01-20), and note the day of the week the action is desired. 2. Enter the code for the desired action and action specifier. The action codes represent the events that are to take place when the scheduled time is reached. Each action also requires an action specifier, which defines what the action will affect (relay, relay group, partition, zone list, user group). The action specifier varies, depending on the type of action selected. The following is a list of the Action Codes (desired actions) used when programming Time-Driven events. Note that these codes are independent of the relay codes programmed during Output Programming in the #93 Menu Mode. Relay Commands Action Code Action Action Specifier 01 Relay On Relay # 02 Relay Off Relay # 03 Relay Close for 2 seconds Relay # 04 Relay Close XX minutes (set in field 1*74) Relay # 05 Relay Close YY seconds (set in field 1*75) Relay # 06 Relay Group On Relay Group # 07 Relay Group Off Relay Group # 08 Relay Group Close for 2 seconds Relay Group # 09 Relay Group Close XX minutes (set in field 1*74) Relay Group # 10 Relay Group Close YY seconds (set in field 1*75) Relay Group # Arm/Disarm Commands Action Code Action Action Specifier 20 Arm-STAY Partition(s) 21 Arm AWAY Partition(s) 22 Disarm Partition(s) 23 Force Arm STAY (Auto- bypass faulted zns) Partition(s) 24 Force Arm AWAY (Auto- bypass faulted zns) Partition(s) 25 Arm INSTANT Partition(s) 26 Arm MAXIMUM Partition(s) • The auto-arm warning (field 2*06) applies when using Time-Driven events to auto-arm. • Temporary schedules do not override an auto-arming or auto-disarming programmed in Time-Driven events. • The auto-arming window cannot be extended using the Installer Code + #82 Mode. Bypass Commands Action Code Action Action Specifier 30 Auto bypass – Zone list Zone list # 31 Auto unbypass – Zone list Zone list # Open/Close Windows Action Code Action Action Specifier 40 Enable Opening Window by partition Partition(s) 41 Enable Closing Window by partition Partition(s) 42 Enable Access Window for access group Access Group Access Control Commands Action Code Action Action Specifier 55 Access Point Grant Access Point # 56 Access Point Grant with Override Access Point # 57 Access Point Protect Access Point # 58 Access Point Bypass Access Point # 59 Access Point Lock Access Point # 60 Access Point Exit Access Point # 61 Access Point Group Grant Group # 62 Access Point Group Grant with Override Group # 63 Access Point Group Protect Group # 64 Access Point Group Bypass Group # 65 Access Point Group Lock Group # 66 Access Point Group Exit Group # 67 Access Point Partition Grant Partition # 68 Access Point Partition Grant with Override Partition # 69 Access Point Protect by Partition Partition # 70 Access Point Bypass by Partition Partition # 71 Access Point Lock by Partition Partition # 72 Access Point Exit by Partition Partition # 73 Access Point Trigger On Trigger # 74 Access Point Trigger Off Trigger # 77 Access Point Group Enable Group # 78 Access Point Group Disable Group # Section 6 – Scheduling Options 6-9 3. Enter the desired activation time (when the action is to take place). Select from: Activation Time Description 1 Beginning of time window. 2 End of time window. 3 During time window active period only (on at beginning of window, off at end). For example, if bypass is selected to activate during the window, zones in a zone list are bypassed at the beginning of the window and unbypassed at the end of the window. 4 Beginning and end of time window (e.g., a coffee break buzzer). In this example, if relay pulse is selected, the relay pulses for 2 seconds at the beginning of the window, signaling the beginning of the coffee break. At the end of the window it pulses again, signaling the end of coffee break. 5 Random time at the start of the time window (occurs within 30 minutes after the start of the time window). NOTE: Since the randomization for choice “5” occurs within 30 minutes after the start of the window, the time window must be of a duration of at least 30 minutes. 6 Random time at the end of the time window (occurs within 30 minutes after the end of the time window). 7 Random during the time window (begins within 30 minutes after the start of the time window and ends within 30 minutes after the end of the time window). NOTE: Since the randomization for choice “7” occurs within 30 minutes after the start of the window, the time window must be of a duration of at least 30 minutes. Field *04 must be enabled for randomization. A user must initiate a random schedule by entering one of the following sequences: • [User Code] + [#] + [41]. This will randomize, up to 30 minutes, the activation time of all devices, programmed for randomization, assigned to the partition the sequence is entered in. Enter the sequence again to turn off the random schedule. • [User Code] + [#] + [42]. This is the same as the method above, except the randomization occurs only on devices with activation times within 6 PM and 5 AM. Enter the same sequence again to turn off the random schedule. UL You must not program Random Scheduling of Time Driven Events for UL installations. Time-Driven Event Programming The following menu items must first be programmed in Output Programming in the #93 Menu Mode: Enter Relay No. (reference identification number) Output Group (if applicable) Restriction Output Type (V-Plex, 4204/4204CF, FSA, or X-10) Zone No. (V-Plex) ECP Address (4204/4204CF or FSA) Relay No. (4204/4204CF) LED No. (FSA) House Code (X-10) Unit Code (X-10) After entering Scheduling Menu Mode, press [0] until the “Timed Events ?” prompt appears. PROMPT EXPLANATION Timed Events ? 1 = YES 0 = NO 0 Enter 1 to program timed events. TIMED EVENT # ? 01-20, 00=Quit 01 Enter the timed event number to be programmed (01-20). Press [✳]. The system then prompts the user to enter the desired action to be taken. Enter 00 at the “TIMED EVENT #?” prompt to quit the timed event menus and display the “Quit ?” prompt. VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-10 01 ACTION ? none 00 Enter the action code for this timed-event number from the list at the left. This could be an output command, an arming command, or any other Time-Driven event. Press [✳] to accept the entry. The prompt for the action specifier appears. ACTION CODES EXPLANATION ACTION SPECIFIER 01=Relay On 02=Relay Off 03=Relay Close for 2 seconds 04=Relay Close XX minutes 05=Relay Close YY seconds Actions 01-05 If you selected actions 01-05, the prompt at the right appears. Enter the relay number. Press [✳] to accept entry. The “Time Window ?” prompt appears. 01 RELAY # ? 00 ACTION CODES EXPLANATION ACTION SPECIFIER 06=Relay Group On 07=Relay Group Off 08=Relay Group Close for 2 seconds 09=Relay Group Close XX minutes 10=Relay Group Close YY seconds Actions 06-10 If you selected actions 06-10, the prompt at the right appears. Enter the relay group number. Press [✳] to accept entry. The “Time Window ?” prompt appears. 01 RELAY GRP # ? 00 20=Arm-STAY 21=Arm AWAY 22=Disarm 23=Force Arm STAY 24=Force Arm AWAY 25=Arm INSTANT 26=Arm MAXIMUM 40=Enable Open Window by Part. 41=Enable Close Window by Part. Actions 21-26 and 40-41 If you selected actions 21-26 or 40-41, the prompt at the right appears. Enter the partition to which the action applies. Enter 0 to select all partitions. Enter a partition number again to deselect it. Press [✳] to accept entry. The “Time Window ?” prompt appears. PART? 12345678 HIT 0-8 X X 30=Auto bypass – Zone list 31=Auto unbypass – Zone list Actions 30-31 If you selected actions 30-31, the prompt at the right appears. Enter the zone list number that contains the zones to be bypassed or unbypassed. Press [✳] to accept entry. The “Time Window ?” prompt appears. 01 ZONE LIST ? ENTER 01-15 01 42=Enable Access Window for Access group(s) Action 42 If you selected action 42, the prompt at the right appears. Enter the group number to which the time window will apply. Press [✳] to accept entry. The “Time Window ?” prompt appears. GROUP ? 12345678 HIT 0-8 X 55=Access Point Grant 56=Access Point Grant w/Override 57=Access Point Protect 58=Access Point Bypass 59=Access Point Lock 60=Access Point Exit Actions 55-60 If you selected actions 55-60, the prompt at the right appears. Enter the access point number. Press [✳] to accept entry. The “Time Window ?” prompt appears. 01 ACCESS POINT # 000 61=Access Point Group Grant 62=Access Point Group Grant w/Override 63=Access Point Group Protect 64=Access Point Group Actions 61-66 and 77-78 If you selected actions 61-66, the prompt at the right appears. Enter the group number. Press [✳] to accept entry. The “Time Window ?” prompt appears. 01 GROUP # 00 Section 6 – Scheduling Options 6-11 Bypass 65=Access Point Group Lock 66=Access Point Group Exit 77=Access Point Group Enable 78=Access Point Group Disable ACTION CODES EXPLANATION ACTION SPECIFIER 67=Access Point Partition Grant 68=Access Point Partition Grant w/Override 69=Access Point Protect by Partition 70=Access Point Bypass by Partition 71=Access Point Lock by Partition 72=Access Point Exit by Partition Actions 67-72 If you selected actions 67-72, the prompt at the right appears. Enter the partition to which the action applies. Enter 0 to select all partitions. Enter a partition number again to deselect it. Press [✳] to accept entry. The “Time Window ?” prompt appears. PART? 12345678 HIT 0-8 X X 73=Access Point Trigger On 74=Access Point Trigger Off Actions 73-74 If actions 73-74 were selected, the prompt at the right will be displayed. Enter the trigger number. Press [✳] to accept entry. The “Time Window ?” prompt appears. 01 TRIGGER # 00 01 Time Window ? 00:00 00:00 01 Enter the time window number (01-20) for which this timed event is to occur. As the number is keyed in, the actual time that has been stored for the time window number is displayed. Press [✳] to accept entry. 01 Active time ? 0 Enter the activation time from 1-10 (listed below). As the number is keyed in, the activation time is displayed. The choices are: 1: Trigger at the start of the window. 2: Trigger at the end of the window. 3: Take effect only for the duration of the window. 4: Trigger at both the start and the end of the window. Example: coffee break buzzer. 5: Random trigger, up to 30 minutes, after the start of the window. 6: Random trigger, up to 30 minutes, after the end of the window. 7: Take effect only for the duration of the window, but random start and end the window up to 30 minutes. Press [✳] to accept entry. Days ? MTWTFSSH Hit 0-8 x x The system then asks for which days the event is to be activated. Press 0 to toggle all days on or off; or press keys 1-8 to toggle the letter “x” under the day on or off (Monday = 1, Holiday = H = 8). When all entries have been made, the “TIMED EVENT #?” prompt is displayed again. Repeat the procedure for each timed event for the installation. Quit ? 1 = YES 0 = NO 0 Enter 0 at the “Quit ?” prompt to return to the main menu choices and continue programming. Enter 1 to quit Scheduling Menu Mode. Section 6 – Scheduling Options 6-1 Limitation of Access Schedules Limitation of Access is a means by which a user’s access code is limited to working during a certain period of time. The system provides 8 Access Schedules, each of which consists of two time windows for each day of the week and two time windows for holidays (typically, one for an opening time window and the second for a closing time window). A user, required to follow a schedule, would be assigned to an access group of the same number (e.g., schedule 1= group 1). The user’s access code is assigned to a group when that user is added to the system. If no limitations apply, enter 0. Limitation of Access Schedule Worksheet Enter the appropriate time window numbers for each access schedule. Acc Mon Tues Wed Thurs Fri Sat Sun Hol Sch W1 W2 W1 W2 W1 W2 W1 W2 W1 W2 W1 W2 W1 W2 W1 W2 1 2 3…8 NOTE: The holidays used for the access groups are the same as those defined in the holiday schedule. Limitation of Access Schedules Programming To program access schedules enter Scheduling Menu Mode Installer Code + # 80. After entering Scheduling Menu Mode, press [0] until the “Access Sched. ?” prompt appears. PROMPT EXPLANATION Access Sched. ? 1 = YES 0 = NO 0 Enter 1 to program access schedules. ACCESS SCHED # ? 01-08, 00 = Quit 01 Enter the access control schedule number between 01 and 08. Press [✳] to accept entry. Enter 00 at the “Access Sched #?” prompt to quit the access control menus and display the Quit ? prompt. MON A1 Window 1? 00:00 00:00 00 Enter the first time-window number (01-20) for this access schedule for the displayed day. As the number is keyed in, the actual time that has been stored for the window is displayed. Press [✳] to continue. MON A1 Window 2 ? 00:00 00:00 00 Enter the second time-window number from 01-20 for this access schedule for the displayed day. As the number is keyed in, the actual time that has been stored for the window is displayed. Press [✳] to continue. TUE A1 Window 1? 00:00 00:00 00 Repeat the procedure for the other days of the week. When the last day of the week has been programmed, the windows for holidays may be entered. Hol A1 Window 1 ? 00:00 00:00 00 Enter the first time-window number for holidays for this access schedule. As the number is keyed in, the actual time that has been stored for the window is displayed. Press [✳] to continue. Hol A1 Window 2 ? 00:00 00:00 00 Enter the second time-window number for holidays for this access schedule. As the number is keyed in, the actual time that has been stored for the window is displayed. Press [✳] to continue. Quit ? Enter 0 at the “Quit ?” prompt to return to the main menu choices and continue programming. VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-14 Enter 0 at the “Quit ?” prompt to return to the main menu choices and continue programming. Enter 1 to quit Scheduling Menu Mode. Temporary Schedules Each partition can be assigned a temporary schedule, which overrides the regular open/close schedule (and the holiday schedule). This schedule takes effect as soon as it is programmed, and remains active for up to one week. Only users with the authority level of manager or higher can program temporary schedules. A temporary schedule affects only the partition from which it is entered. Temporary schedules can also be reused at later dates simply by scrolling (pressing [#]) to the “DAYS?” prompt and activating the appropriate days. This should be considered when defining daily time windows. Temporary Schedule Worksheet Partition/Windows Mon Tue Wed Thu Fri Sat Sun 1 Disarm Window Start Time HH:MM Stop Time HH:MM Arm Window Start Time HH:MM Stop Time HH:MM 2…8 Disarm Window Start Time HH:MM Stop Time HH:MM Arm Window Start Time HH:MM Stop Time HH:MM Temporary Schedules Programming Enter User Code + [#] + 81 to enter this mode. PROMPT EXPLANATION Mon DISARM WIND. 00:00AM 00:00AM This prompt is for entering the start and end times of the disarm (opening) window for Monday. Upon entry of this mode, the cursor is positioned on the tens of hours digit of the start time of the disarm window. Enter the desired hour. Press [✳] to move to the minutes field. The minutes are entered in the same manner. Press [✳] to move to the AM/PM position. Pressing any key in the 0-9 range toggles the AM/PM indication. Repeat the procedure for the stop time entry. Press [✳] to store the entries and move to the arming (closing) window for Monday. Pressing [#] scrolls you through the prompts without making any changes. Mon ARM WINDOW 00:00AM 00:00AM This prompt is for entering the start and end times of the arm (closing) window for Monday. The cursor is positioned on the tens of hours digit of the start time of the arm window. Enter the hour. Press [✳] to move to the minutes field. The minutes are entered in the same manner. Press [✳] to move to the AM/PM position. Pressing any key in the 0-9 range toggles the AM/PM indication. Repeat the procedure for the stop time entry. After the windows for that day have been completed, the system prompts for disarm and arm time windows for the next day. Press [#] if no changes are desired. VISTA-128BP/VISTA-250BP Installation and Setup Guide 6-14 Tue DISARM WIND. 00:00AM 00:00AM Repeat the procedure described above for all days of the week. When all the windows for all the days have been completed, the system prompts for which days of the schedule are to be activated. Days ? MTWTFSS Hit 0-7 x x This is the prompt that actually activates the temporary schedule. To select the days to be activated, enter 1-7 (Monday = 1). An “X” appears under that day, indicating the temporary schedule for that day is active. Entering a day’s number again deactivates that day. Pressing 0 toggles all days on/off. The temporary schedule is in effect only for the days highlighted with the letter “x” under them. As the week progresses, the selected days are reset to the inactive state, but all other entries for the temporary schedule remain programmed. Press [✳] to store the entries or press [#] to exit the Temporary Schedule Entry Mode without making any changes. User Scheduling Menu Mode The system provides up to 20 “timers” available to the end user to control output devices. The output devices themselves are programmed into the system by the installer during Output Programming in the #93 Menu Mode. The end user needs only to know the output device number and its alpha descriptor. The installer may set certain outputs to be “restricted” during Output Programming (this prevents the end user from controlling doors, pumps, bell outputs, etc.) To enter this mode, the user enters User Code + [#] + 83. PROMPT EXPLANATION Output Timer # ? 01-20, 00=Quit 01 Enter the output timer number to be programmed (01-20). Press [✳] to accept entry and move to the next prompt. Enter 00 to quit and return to normal operating mode. 06 07:00P 11:45P PORCH LITE 04 If that timer number has already been programmed, a summary screen appears. In this example: 06 = Timer # 07:00PM = Start Time 11:45PM = Stop Time PORCH LITE = Descriptor for Output Device # 4 04 = Output Device # affected by this timer Press [✳] to continue. 06 ENTER OUTPUT# PORCH LITE 04 Enter the desired output number (01-96). As the number is entered, the descriptor for that output device is displayed. Press [✳] to continue. Entering 00 as the output number deletes the timer (Timer 06, in this example) and displays an output descriptor of “None.” Output devices are programmed via #93 Menu Mode. PROMPT EXPLANATION 06 ON TIME ? 07:00 PM The cursor is positioned on the tens of hours digit of the ON time. Enter the desired hour. Press [✳] to move to the minutes field. The minutes are entered in the same manner. The AM/PM indication is toggled by hitting any key from 0-9 while the cursor is under the AM/PM position. Press [✳] to continue. 06 OFF TIME ? 11:45 PM The cursor positioned on the tens of hours digit of the OFF time. Enter the desired hour. Press [✳] to move to the minutes field. The minutes are entered in the same manner. The AM/PM indication is toggled by hitting any key in the 0-9 range while the cursor is under the AM/PM position. Press [✳] to continue. Section 6 – Scheduling Options 6-15 06 DAYS? MTWTFSS HIT 0-7 x x To select the days to be activated, enter 1-7 (Monday = 1). An “x” appears under that day, indicating the output for that day is active. Entering a day’s number again deactivates that day. Pressing 0 toggles all days on/off. The outputs are in effect only for the days highlighted with the letter “x” under them. As the week progresses, the selected days are reset to the inactive state, unless the permanent option is selected (next screen prompt). When completed, press [✳] to continue. 06 Permanent ? 0 = NO,1 = YES 0 Selecting “Permanent” (1) means that this schedule will be in effect on a continuous basis. Selecting 0 means that this schedule will be in effect for one week only. The letter “x” under the day is then cleared, but all other entries for the output device remain programmed. Press [✳] to accept entry. The system quits User Scheduling Mode and returns to normal operating mode. 7-1 SECTION 7 Downloading Primer (Remote Downloading is not a UL Listed feature) •••••••••••••••••••••••••••••••••••••••••••••••• • General Information Downloading allows the operator to remotely access, program, and control the security system over normal telephone lines. Anything that can be done directly from the keypad can be done remotely, using ADEMCO’s COMPASS downloading software. To communicate with the control panel, the following is required: 1. IBM PC-compatible 486 33MHz PC or better with 30 MB of available hard disk space and at least 8MB of RAM (12MB is preferred). Windows 3.X, Windows 95, 98, or Windows NT. 2. One of the following modems: • ADEMCO CIA • Hayes Smartmodem 1200 (external: level 1.2 or higher; internal: level 1.1 or higher) • Hayes Optima 24 + Fax 96 external • Hayes Optima 336 • BizComp Intellimodem 1200 w/volume • BizComp Intellimodem 2400 Other brands are not compatible, even if claimed to be 100% compatible. 3. COMPASS DOWNLOADING software available on CD ROM with a complete User’s Manual. It may also be downloaded from the ADEMCO web page. The web address is http://www.ademco.com. Internal modems must have a 4-position DIP switch. Modems with a 6-position DIP switch will not work. Access Security The following four levels of protection guard the control against compromise while it is being accessed from a remote location: 1. Security code handshake: The subscriber’s account number as well as an 8-digit ID number (known only to the office) must be matched between the control and computer. 2. Hang-up and callback: The control panel “hangs up” and calls the computer back at the pre- programmed number only if the security codes match. 3. Data encryption: All data that is exchanged between the computer and control is encrypted to reduce the possibility of anyone “tapping” the line and corrupting data. 4. Operator access levels: Operators may be assigned various levels of access to the downloader, each having its own log-on code. The access levels allow the operators read/write capabilities of the customers’ account information. For a detailed explanation of the access levels, see the downloading software User Manual. NOTES: • Each time the control panel is accessed successfully, a Callback Requested report is sent to the central station, if Opening reports are programmed. • When the system is downloading, the keypad displays “MODEM COMM.” • After each download or save, an automatic time stamp is done, to indicate the last download (or save) and the operator ID number. • A complete hard copy of each individual account can be obtained by connecting a printer to the computer. Refer to your computer Owner’s Manual or contact your dealer for printer recommendations. Unattended Download Unattended download allows the control panel to communicate with the download computer without an operator at the computer. This feature is useful on new installations. VISTA-128BP/VISTA-250BP Installation and Setup Guide 7-2 The installer can mount the control, attach a keypad and phone line, and continue to wire the rest of the installation while the system is automatically downloaded. The following items must be programmed for unattended download: • The account number (field ✳32) • Primary central station telephone number (field ✳33) • The download telephone number (field ✳35) • Unattended Mode (enable in field ✳54.) NOTE: The default for field ✳54 is enabled (1). Installer Unattended Program Mode The Installer Unattended Program Mode allows the installer to program fields ✳32, ✳33, and ✳35 without entering the normal program mode. Press 0 (NO) or 1 (YES) in response to the displayed menu selection. Pressing 0 displays the next choice in sequence. To access this mode, enter Installer Code + [#] + [89]. The following prompt appears: PROMPT EXPLANATION Unattend. Phone 1 = YES 0 = NO 0 Press 1 to enter the unattended phone number. Unattend. Phone 1 Enter the telephone number of the download software modem. Enter up to 17 digits, 0-9; A key = ✳✳✳✳, B key = #, C key = 2-Sec. Pause. Do not fill unused spaces. Press the ✳ key to accept the phone number and exit. Press the # key to exit without changing any data. The system displays the Quit menu prompt. Press 1 to exit the Installer Unattended Program Mode, or 0 to continue to the next prompt. Unattended Acct# 1 = YES 0 = NO 0 Press 1 to enter the unattended account number. Unattended Acct# 15-15-15-15 Enter a 3-or 4-digit (depending on report format) account number 00-09; B-F (11-15). Each number requires a 2-digit entry so as to allow entry of hexadecimal digits (B-F). If a 3-digit account number is to be used, enter digits in the first 3 locations, and enter 00 in the last location. Press the ✳ to exit without changing any data. The system displays the Quit menu prompt. Press 1 to exit, or 0 to continue. Primary Phone 1 = YES 0 = NO 0 Press 1 to enter the primary phone number. Primary Phone 0 Enter the primary central station telephone number. Enter up to 17 digits, 0-9; A key = ✳, B key = #, C key = 2-Sec. Pause. Do not fill unused spaces. Press the D key accept the phone number and exit. Press the ✳ to exit without changing any data. The system displays the Quit menu prompt. Press 1 to exit, or 0 to continue. Quit ? 1 = YES 0 = NO 0 Enter 1 to quit the Installer Unattended Program Mode. Enter 0 at the “Quit ?” prompt to return to the first menu prompt, “UNATTEND. PHONE”. Trig. Unattended 1 = YES 0 = NO 0 Enter 1 to initiate the unattended download at this time. Otherwise enter 0. NOTE: The ADEMCO Compass Downloader must be in Unattended Mode. An unattended download may be initiated by the installer or end user at any time by entering User Code + [#] + [1]. Section 7 – Downloading 7-3 Getting On-Line with a Control Panel At the protected premises, the control panel must be connected to the existing telephone line (refer to SECTION 3: Installing the Control). No programming of the panel is required before downloading to an initial installation unless you are performing an unattended download. When establishing a connection between the computer and the control panel, the following occurs: Stage What Happens 1 The computer calls up the control panel. (The phone number for each customer must be entered into the customer’s account file on the computer.) 2 The control panel answers the phone call at the pre-programmed ring count and executes a handshake with the computer. 3 The computer sends a request for callback to the control, unless callback is not required. 4 The panel acknowledges the request and hangs up. During the next few seconds, the control processes the request, making sure certain encrypted information received from the computer matches its own memory. 5 Upon a successful match, the control panel seizes the phone line and calls the computer back, unless callback is not required. (The phone number to which the computer’s modem is connected must be programmed into the control field ✳35.) 6 The computer answers, usually by the second ring, and executes a handshake with the panel. 7 The panel then sends other default information to the computer. If this information matches the computer’s information, a successful link is established. The system is now “on-line” with the computer. • Alarms and Trouble responses and reports are disabled during actual uploading or downloading sessions. If you are on-line, but not actively uploading or downloading, all alarms report immediately. All other reports are delayed until you complete the session. • The keypads remain active when on-line with a control, but are inactive during actual uploading or downloading sessions. VISTA-128BP/VISTA-250BP Installation and Setup Guide 7-16 To download a control without programming any information, perform the following steps: Step Action 1 Enter the Installer Code + [#] + [5]. The panel temporarily enables a ring count of 5 and sets the Download Callback option to “1” (callback not required). 2 From the computer, call the panel using the downloader software set to “First Communication” Mode. The downloader establishes a session with no callback. The panel information can then be downloaded. On-Line Control Functions The following functions can be performed while on-line with a control panel (see field *37): • Arm the system in the AWAY Mode; disarm the system • Bypass a zone • Force the system to accept a new program download • Shut down communication (dialer) functions (for nonpayment of monitoring fees in an owned system) • Shut down all security system functions (for nonpayment for a leased system) • Inhibit local keypad programming (prevents takeover of your accounts) • Leave a message for customer NOTE: Messages sent to the control panel from the downloader will be viewable at ALL partitions. • Command the system to upload a copy of its resident program to the office • Read: arming status, AC power status, list of faulted zones, list of bypassed zones, 1000 event log, list of zones currently in alarm, list of zones currently in trouble, and ECP equipment list • Set the real-time clock Scheduled Download The VISTA-128BP/VISTA-250BP can be programmed to periodically and automatically call the downloader. When this option is set up, the system will call the downloader at a scheduled time. Once the connection is established with the modem, the downloader controls which functions are performed (download, arm, upload event log, etc.). The programmable options for the scheduled download are located in the #93 Menu Mode section under the main menu prompt Scheduled Check-in. The options are as follows: • Check-in interval (weekly, monthly quarterly, yearly) • Quarter of the year (if quarterly is selected) • Month of the year (if monthly, quarterly, or yearly is selected) • Day of the month (if monthly, quarterly, or yearly is selected) • Day of the week (if weekly is selected) • Time of day Refer to the #93 Menu Mode section in the Programming Guide for sequence of the prompts. Direct-Wire Downloading The VISTA-128BP/VISTA-250BP can be downloaded without using a modem or telephone line by using a 4100SM Serial Module and Compass Downloading Software. The direct-wire downloading connection is to be temporary, and is not part of the permanent installation. Direct-wire downloading is meant as a tool for the installer during the installation process. The connections between the control and the 4100SM are different than those shown in the 4100SM Installation Instructions. See Figure 7- 1 for the correct connections. In addition, in place of the green wire, referred to in step 2 of the “IN CASE OF DIFFICULTY” section of the 4100SM Instructions, use the violet wire instead. VISTA-128BP/VISTA-250BP Installation and Setup Guide 7-2 Connector J8 on the main PC board (see the Summary of Connections diagram on the inside back cover of this manual) is intended to be interfaced to either a local serial printer (see SECTION 3:Installing the Control) or a computer. Make connections to a computer as shown below. Note that the violet wire connection for a computer differs from that used when connecting a serial printer. Remove the VA8201 Alpha Pager Module, if it is installed, before performing the direct-wire download. It may be reconnected once the direct-wire download is completed. Figure 7-1: Direct-Wire Downloading Connections Telco Handoff Telco handoff is another method of getting on-line with the downloader. The installer or customer enters the User Code + [#] + [1], while on the phone line with the computer’s modem phone line. The customer will get cut-off and the panel and download computer will establish a connection. 8-1 SECTION 8 Setting the Real-Time Clock •••••••••••••••••••••••••••••••••••••••••••••••• • General Information This system provides a real-time clock, which must be set in order for the system’s event log to keep track of events by time and date. It must also be set in order to execute scheduling programs (Time-Driven events). If you are using Panel Linking, you can set the Real- Time clock at one panel and have the system automatically update the time and date at the other control panels. Use a 6139/6160 alpha keypad to set the real- time clock, or set the clock via the downloader software. Only users with Installer or Master authority level can set the clock. Setting the Time and Date To set the real time clock, perform the following steps: Step Action 1 Enter Installer or Master Code + [#] 63. Typical display shows: TIME/DATE –– THU 12:01 AM 01/01/90 The day of the week is automatically calculated based on the date entered. Time and date entries are made by simply entering the appropriate hour, minute, month, day and year. Press [✳] to move the cursor to the right of the display, to the next position. Press [#] to move the cursor to the left of the display, to the previous position. 2 Enter the correct hour. Then press [✳] to move to the “minutes” field. 3 Enter the correct minutes. Press [✳] to move to the AM/PM position. Step Action 4 Press any key 0-9 to change AM to PM, or PM to AM. Press [✳] to move cursor to the “month” field position. 5 Enter the correct month using a 2-digit entry. Press [✳] to move cursor to the “day” field position. 6 Enter the correct day using a 2-digit entry. Press [✳] to move cursor to the “year” field position. 7 Enter the correct year. Press [✳] to continue. 8 The following display appears: Broadcast Time? 1=YES 0=NO 0 If panel linking is being used, enter 1 (YES) to send this time and date setting to all the VISTA-128BP/VISTA-250BP Installation and Setup Guide 8-2 Press [✳] to exit the real-time clock edit mode. 8-3 9-1 SECTION 9 User Access Codes •••••••••••••••••••••••••••••••••••••••••••••••• • General Information The VISTA-128BP allows a total of 150 security access codes to be allocated. The VISTA-250BP allows a total of 250 security access codes to be allocated. Each security access code is identified by a user ID number. Regardless of the number of partitions each code has access to, it occupies only one user slot in the system. If a code is not used in all partitions, that user ID number cannot be used again. The Quick Arm feature can also be programmed (partition-specific program field *29). The Quick Arm feature allows the user to arm the system by pressing the [#] key instead of the security code. The security code must always be entered to disarm the system. • A user code other than the installer code must be programmed in order for the Quick Arm feature to function. • Users 001-050 are the only users that can perform panel linking and are automatically assigned panel linking access. The system is shipped with the following defaults for the user codes: User 4-Digit Code Alpha Descriptor User 1 (Installer) 4140 INSTLR User 2 1234 MASTER User Codes & Levels of Authority Each user of the system can be assigned a level of authority, which authorizes the user for certain system functions. A user can have different levels of authority within different partitions Use the “View Capabilities” keypad function (User Code + [✳] + [✳]) to view the partitions and authority levels for which a particular user is authorized. These levels are described below. Level 0: Installer (User 1) Code • Programmed in field *00 (default = 4-1-4-0). Installer Open/Close reporting selected in field *39. • Can perform all system functions (arm, disarm, bypass, etc.), but cannot disarm if armed by another code (or by Quick Arm). • Can add, delete, or change all other codes, and can select Open/Close reports for any user. • Is the only code that can be used to enter program mode. The Installer Code can be prevented from re-entering the Program Mode by exiting using ∗98. • Must program at least one Master Code during initial installation. Master Codes are codes intended for use by the primary user(s) of the system. Level 1: Master Codes • Can perform all normal system functions. • Can be used to assign up to 148 lower-level codes, which can be used by other users of the system. • Cannot assign anybody a level of 0 or 1. • May change his own code. • Can add, delete, or change Manager or Operator Codes. Each user’s code can be individually eliminated or changed at any time. • Open/Close reporting is automatically the same as that of the Master who is adding the new user. Level 2: Manager Codes • Can perform all system functions (arm, disarm, bypass, etc.) programmed by Master. • May add, delete, or change other users of the system below this level (Manager cannot assign anybody a level of 0, 1, or 2). • May change his own code. • Open/Close reporting is automatically the same as that of the Manager who is adding the new user. Levels 3-5: Operator Codes • Can operate a partition, but cannot add or modify any user code (see table below). Level Title Functions Permitted 3 Operator A Arm, Disarm, Bypass 4 Operator B Arm, Disarm 5 Operator C Arm, Disarm only if armed with same code VISTA-128BP/VISTA-250BP Installation and Setup Guide 9-2 • Operator C (sometimes known as the Babysitter Code) cannot disarm the system unless the system was armed with that code. This code is usually assigned to persons who may need to arm and disarm the system at specific times only (e.g., a babysitter needs to control the system only when babysitting). Level 6: Duress Codes • Sends a silent alarm to a central monitoring station if the user is being forced to disarm (or arm) the system under threat (system must be connected to a central station). • When the system’s Auxiliary Voltage Triggers are connected to another communication’s media (Derived Channel/Long Range Radio), note that duress is signaled on the same trigger that signals silent panic (whereas duress has its own unique report when digitally communicated). • Assigned on a partition-by-partition basis, and can be any code or codes desired. Duress Reporting NOTE: A non-zero report code for zone 992 (duress) must be programmed, and partition-specific field *85 duress location enabled, to enable Duress reporting. • The Duress report-triggering logic activates on the 5th key depression (such as OFF), not the 4th key depression (last digit of code). Duress reports are not triggered if the 5th key is a [*], such as when you perform a GOTO or view the capabilities of a user. General Rules on Authority Levels and Changes The following rules apply to users when making modifications within the system based on the user code authority levels: • Master Codes and all lower-level codes can be used interchangeably when performing system functions within a partition (a system armed with a user’s temporary code can be disarmed with the Master Code or another user’s temporary code), except the Operator Level C Code described above. • A user may not delete or change the user code of the SAME or HIGHER authority than that which he is assigned. • A user (levels 0, 1 and 2 only) may only ADD users to a LOWER authority level. • A user may assign other users access to only those partitions to which he himself has access. • A user code can be DELETED or CHANGED only from within the partition it was created in. • User numbers must be entered in 3 digits. Single-digit user numbers must, therefore, always be preceded by a “00” (e.g., 003, 004, 005, etc.). Make sure the end user understands this requirement. Temporary codes are entered as 4-digit numbers. Open/Close Reporting Note: When a user is added, the system prompts for Open/Close reporting capability only if the installer is adding the new user. When a Master or Manager adds a new user, the new user’s Open/Close reporting is the same as that of the Master or Manager who is adding the user. If Open/Close reports are required to be selectable by the Master or Manager, the Installer should assign two Master or Manager user codes: one with Open/Close reporting enabled, and one without. Note that Open/Close reporting of Quick Arm is enabled if User 002 is enabled for Open/Close reporting, and that Quick Arm reports as User 000. In order for Quick Arm reports to be sent for all partitions, User 002 must have authority and Open/Close must be enabled for all partitions. If a code with access to all partitions is not desired, it is suggested that user 002 be assigned authority level 5 in all partitions, and that the code be kept secret. Authority level 5 cannot disarm the system unless armed by that user. ADEMCO Contact ID format is capable of reporting Users 001-150 uniquely. If any other report format is used, only user numbers 001 – 015 can uniquely report to the central station. Users 016 – 150 will report as User 015. Multiple Partition Access Each user is programmed for a primary (home) partition. A user can also be given access to operate one or more additional partitions. Within each partition, each user may be programmed to have different levels of authority. For example, User 003, the VP of Engineering, could be assigned to work within the Engineering Department (Partition 1) of ABC Manufacturing. Because he needs the full capabilities in his area, he is assigned as a MASTER with Level 1 authority. He must also be able to gain access to the manufacturing area (Partition 2) on an emergency basis. You can set this up easily by requesting that he also be assigned to Partition 2, with a level of authority set lower, such as Level 4 (OPERATOR Level B). The control automatically assigns him the same user number within Partition 2. EXAMPLE OF MULTIPLE PARTITION ACCESS Part 1 Part 2 Part 3 Part 4 Part 5 Part 6 Part 7 Part 8 User 3 User 3 Level 1 Level 4 Master Oper B VISTA-128BP/VISTA-250BP Installation and Setup Guide 9-2 In the above example, User 3 has MASTER authority in Partition 1 and OPERATOR B authority in Partition 2. His user number is the same for both partitions. Note that if a user number is already being used in a partition, the system will automatically assign a new user an unused number. Also notice that no access is allowed for this user into Partitions 3 – 8. Attempts to access these partitions would be denied automatically. Adding a Master, Manager, or Operator Code During user code entry, normal key depressions at other keypads in a partition are ignored. However, panic key depression causes an alarm and terminates user entry. When entering panel link users (001-050) on the local panel, the other remote panels will be prevented from entering panel link user data until the local panel exits User Edit Mode. Enter Installer Code†+ [8] + new user no. (002- 250) + new user’s code †Or Master or Manager Code, but the code must be a higher level of authority than the code being changed (e.g., a Manager Code can add an Operator-level Code, but cannot add a Master or another Manager Code). Keypad prompts for the authority level for this user. NOTE: All references to the number of user codes pertain to the VISTA-250BP. The VISTA- 128BP allows only 150 user codes. PROMPT EXPLANATION User Number = 003 Enter Auth. Level Enter the level number as follows: 1 = Master 2 = Manager 3 = Operator Level A 4 = Operator Level B 5 = Operator Level C 6 = Duress Keypad then prompts for Open/Close reporting option for this user. Open/Close Rep.? 0 = NO , 1 = YES Press 0 (NO) or 1 (YES), depending on whether or not arming/disarming by this user will trigger Opening and Closing reports. This prompt appears only if the Installer Code is used to add a user. Group Bypassing? 0 = NO , 1 = YES Enter 1 (YES) to allow this user to perform group bypasses. Enter 0 (NO) this user will not be able to perform group bypasses. NOTE: In addition to enabling the user for group bypassing, the user must also have access to the partition(s) containing the zones being bypassed and have global arming capability. Access Group? Enter 0-8 If access schedules have been programmed, this prompt appears. Enter the user’s access group number (1-8) if this user should have limited access to the system. Enter 0 if no access group should be assigned. RF Button ? 0=NO , 1=YES If a 5800 Series button transmitter has been enabled for arming/disarming functions, and is not assigned to a user, this prompt appears. Press 0 (NO) or 1 (YES). Enter Button ZN # (001-087) If you answered “yes” to the RF button question, the zone number for the button is requested. Enter any one of the zone numbers assigned to the button transmitter as AWAY, STAY, or DISARM. The system then assigns all buttons of the transmitter to this user number. Multi-Access ? 0 = NO , 1 = YES Press 0 (NO) if the user is to have access to this partition only. Press 1 (YES) if the user is to have access to more than one partition. If NO, the program exits this mode. If YES, the keypad prompts for the Global Arm option for this user. Global Arm ? 0 = NO , 1 = YES Press 0 (NO) or 1 (YES), depending on whether this user will be allowed to arm more than one partition via Global Arm prompts. The keypad now prompts for the user’s access to the next partition. Part. 2 – SHOP ? 0 = NO , 1 = YES Press 0 (NO) or 1 (YES), depending on whether this user will have access to the displayed partition number. If NO, the keypad displays this prompt for the next partition number in sequence. If YES, the keypad prompts for the following: • User’s authority level in the displayed partition (see Authority Level prompt above). VISTA-128BP/VISTA-250BP Installation and Setup Guide 9-4 • Open/Close option for this user in the displayed partition (see Open/Close prompt above). • Global Arm option for this user in the displayed partition. When all partitions have been displayed, the keypad will scroll through all partitions to which access has been assigned, and will display the user number, authority level, open/close and global arm options that were programmed for each partition to which the user was granted access. PROMPT EXPLANATION XMT USER DATA 1 = YES 0 = NO If the user number is from 001-050 this appears. Answer YES (1) to have the system send the user’s attributes to all the other control panels that are “linked” to this control. If you answer NO (0), the system displays the following prompt on the next page. INDV USER PGM 1 = YES 0 = NO Answer YES (1) to link to another control panel and manually enter the user into partition(s) in that control panel. If you answer NO (0), the system scrolls through each partition displaying a summary of the user’s attributes in each partition (see next prompt). Part. 1 A0* WHSE User 003 Auth=3G. Note that the “G” following the authority level indicates that the global arm feature is enabled for this user in the displayed partition, and that the period at the end of the second line indicates Open/Close reporting is enabled for this user in the displayed partition. The “T” indicates the partition from which the user may be changed or deleted. Changing a Master, Manager, or Operator Code Enter Installer Code*+ [8] + new user no. (002-250) + new user’s code *Or Master or Manager Code, but the code must be a higher level of authority than the code being changed (e.g. a Manager Code can add an Operator-level Code, but cannot add a Master or another Manager Code). NOTE: The VISTA-128BP allows only 150 user codes. PROMPT EXPLANATION User Number = 003 NEW USER? The system detects that the user number is already assigned, and prompts if this is a new user. Press 0 (NO). The system then confirms that the change is allowed based on authorization level. Adding an RF Key to an Existing User To add an RF key to an existing user, or to change a user’s global arm option, first delete that user’s code, then re-add the user code as described in the “Adding a Master, Manager, or Operator Code” paragraph. Deleting a Master, Manager, or Operator Code Enter your code*+ [8] + new user no. (002-150) + your code again *Or Master or Manager Code, but the code must be a higher level of authority than the code being changed (e.g. a Manager Code can add an Operator-level Code, but cannot add a Master or another Manager Code). NOTE: The VISTA-128BP allows only 150 user codes. PROMPT EXPLANATION OK TO DELETE 003? 0=NO 1=YES The system prompts to confirm that you want to delete this user. Press 0 (NO) or 1 (YES). If you answered “yes,” that user’s code is removed from all partitions to which it was assigned, and all authorization levels and other information about that user are deleted. Note that a user can be deleted only by a user with a higher authority level. A user cannot delete himself. Section 9 - User Access Codes 9-5 A user code can be deleted only from the partition through which it was entered. If an attempt is made to delete from another partition, the message “User [XXX] Not Deleted” is displayed. Exiting the User Edit Mode Press either [✴] or [#], or don’t press any key for 10 seconds. 10-1 SECTION 10 Testing the System •••••••••••••••••••••••••••••••••••••••••••••••• • Battery Test When AC power is present, the VISTA-128BP/VISTA- 250BP runs a brief battery test every 60 seconds to determine if there is a battery connected, and runs an extended battery test every 4 hours to check on the battery’s condition. If the VISTA-128BP/VISTA-250BP finds that the battery voltage is low (less than approximately 11.5V), it initiates a keypad “SYSTEM LOBAT” display and a rapid keypad beeping sound. It also sends a Low Battery report to the central station (if programmed). The keypad is cleared by entering any security code + OFF, and a Restore report is sent to the central station if the situation has been corrected. Dialer Test The VISTA-128BP/VISTA-250BP may be programmed to automatically transmit test reports to a central station at intervals ranging from once per hour to once per 9999 hours (field ✳27). UL requires the test report to be transmitted at least once every 24 hours. The system can be programmed to send the first report at any time of the day, or on any day of the week (field ✳83). Burglary Walk-Test (Code + [5] TEST) This test causes the system to sound keypad beeps in response to faults on zones for the purpose of allowing proper zone operation to be checked without triggering alarms. This test can be activated by any-level user by entering the corresponding security code and pressing TEST while the burglary portion of the system is disarmed. UL requires that this test be conducted on a weekly basis. When this test is first entered, the system activates the alarm output for 3 seconds. The system sends a Start of Walk-Test message to the central station. The keypad displays “Burg Walk Test in Progress” and sounds a single beep every 15 seconds while the test remains active. Open and close each protected door and window in turn. Each action should produce 3 beeps from the keypad. Walk in front of any motion detectors. Listen for three beeps when the detector senses movement. The keypad displays the zone number and alpha descriptor while a door or window remains open or while a detector remains activated. The system automatically issues a Zone 8 Glassbreak Detector Power Reset about 10 seconds after it finds a fault on this zone, to allow faulted detectors to be reset. To end this test, enter any security code and press OFF. An End of Walk-Test message is sent to the central station. The system automatically exits the Test mode if there is no activity (no doors or windows are opened and closed, no motion detectors are activated, etc.) for 30 minutes on the VISTA-128BP, 60 minutes on the VISTA-250BP. The system beeps the keypad(s) twice every 5 seconds during the last 5 minutes as a warning that it is about to exit the Test mode and return to normal operation. Armed Burglary System Test Alarm messages are sent to the central station during the armed system tests. Notify the central station that a test will be in progress. VISTA-128BP/VISTA-250BP Installation and Setup Guide 10-2 A display of “COMM. FAILURE” indicates a failure to communicate (no kissoff by the receiver at the central station after the maximum number of transmission attempts is tried). If this occurs, verify that the phone line is connected, the correct report format is programmed, etc. To perform an armed burglary test, proceed as follows: Step Action 1 Notify the central station that a test of the system is being performed. 2 Arm the system. 3 Fault one or more zones. 4 Silence alarm sounder(s) each time by entering the code and pressing OFF. NOTE: The system must be rearmed after each code + off sequence. 5 Check that entry/exit delay zones provide the assigned delay times. Step Action 6 Check the keypad-initiated alarms, if programmed, by pressing the panic key pairs (✳ and #, 1 and ✳, and/or 3 and #). The word ALARM and a descriptor “999” are displayed for ✳ and #. If [1] and [✳] are pressed, “995” is displayed; if [3] and [#] are pressed, “996” is displayed. 7 If the system has been programmed for audible emergency, the keypad emits a loud, steady alarm sound. Silence the alarm by entering the security code and pressing OFF. If the system has been programmed for silent panic, there are no audible alarms or displays. A report is sent to the central station, however. 8 Notify the central station that all tests are finished, and verify results with them. Testing Wireless Transmitters Transmitter ID Sniffer Mode Use the Transmitter Sniffer Mode to test that transmitters have all been properly programmed. If a transmitter does not have its serial number “enrolled,” it will not turn off its zone number. To enter the Transmitter ID Sniffer Mode, proceed as follows: Step Action 1 Enter Installer Code + [#] + [3]. The keypad displays all zone numbers of wireless units programmed into the system. 2 Fault each wireless zone, causing each device to transmit. As the system receives a signal from each of the transmitters, the zone number of that transmitter disappears from the display. 3 Enter Installer Code + OFF to exit the Sniffer Mode. Go/No Go Test Mode Checking the transmitters in this mode assists in determining good mounting locations, and verifies that the RF transmission has sufficient signal amplitude margin for the installed system. • All partitions containing wireless transmitters must be placed in the test mode for sensitivity reduction of the RF receiver (50% sensitivity). Otherwise, the RF receiver remains at full strength. • Make sure that all partitions are disarmed when performing this test, as the wireless receiver gain is reduced in half. To enter the Go/No Go Test Mode, proceed as follows: Step Action 1 Enter Installer Code + [5]. 2 Fault each wireless transmitter, causing each device to transmit. NOTE: If a single receiver is used, the keypad beeps three times to indicate signal reception. If two receivers are used, the keypad beeps once if the first receiver received the signal, twice if the second receiver received the signal, and three times if both receivers heard the signal. 3 If the keypad does not beep, reorient or move the transmitter to another location. Usually a few inches in either direction is all that is required. 4 Enter Installer Code + OFF to exit the VISTA-128BP/VISTA-250BP Installation and Setup Guide 10-2 Go/No Go Test Mode. Trouble Conditions Check or Trouble Messages Display Description CHECK or TRBL (as per field 1✳07) This indicates that a problem exists on the zone number displayed. Zone trouble may be caused by one of the following conditions: • A hardwired fire zone is open (broken wire). • A Day/Night zone (zone type 5) is faulted. • A polling loop zone is not seen by the control panel. • A polling loop zone has been tampered (cover removed on a 4190). • A wireless zone has not checked in during the time programmed in field 1✳31. • A 5800 Series transmitter has been tampered (cover removed). CHECK 6XX XX = 01-32 This indicates a trouble on a 4204CF Supervised Bell Output (corresponding relay number 01-32). CHECK 8XX XX = 00-30 This indicates a trouble on a peripheral device (connected to the panel’s keypad terminals) of the corresponding device address (00-30). CHECK 9XX XX = 00-99 This indicates that a system trouble exists (RF receiver, bell output, etc.). If the problem has been corrected, enter an OFF sequence (Security Code + OFF) twice to clear the display. Power Failure Display Description AC LOSS POWER LED is off This indicates that the system is operating on battery power only. Check to see that the circuit breaker for the branch circuit that your system’s transformer is wired to has not been accidentally turned off. Instruct the user to call a service representative immediately if AC power cannot be restored. Other System Messages Display Description COMM FAILURE This indicates that a failure occurred in the telephone communication portion of your system. LO BAT This indicates that a low-battery condition exists in the wireless transmitter displayed. Pressing any key silences the audible warning sound. SYSTEM LO BAT This indicates that a low-battery condition exists with the system’s backup battery. RCVR SETUP ERROR This indicates that the system has more wireless zones programmed than the wireless receiver can support. If this is not corrected, none of the zones in the system will be protected. If additional wireless zones are desired, use an appropriate receiver. MODEM COMM This indicates that the control is on-line with a remote computer. To the Installer Regular maintenance and inspection (at least annually) by the installer and frequent testing by the user are vital to continuous satisfactory operation of any alarm system. The installer should assume the responsibility of developing and offering a regular maintenance program to the user as well as acquainting the user with the proper operation and limitations of the alarm system and its component parts. Recommendations must be included for a specific program of frequent testing (at least weekly) to ensure the system’s proper operation at all times. Turning the System over to the User Fully explain the operation of the system to the user by going over each of its functions, as well as the User’s Manual supplied. In particular, explain the operation of each zone (entry/exit, perimeter, interior, fire, etc.). Be sure the user understands how to operate any emergency feature(s) programmed into the system. VISTA-128BP/VISTA-250BP Installation and Setup Guide 10-4 Contacting Technical Support PLEASE, before you call Technical Support, be sure you: • READ THE INSTRUCTIONS! • Check all wiring connections. • Determine that the power supply and/or backup battery are supplying proper voltages. • Verify your programming information where applicable. • Verify that all keypads and devices are addressed properly. • Note the proper model number of this product, and the version level (if known) along with any documentation that came with the product. • Note your ADEMCO customer number and/or company name. Having this information handy will make it easier for us to serve you quickly and effectively. You may contact Technical Support via Toll-Free Fax. Please include your return fax number. You will receive a reply within 24 hours. You may also contact Technical Support via modem to ATLIS-BBS, Tech Support’s Electronic Bulletin Board System. Replies are posted within 24 hours. Technical Support:.................................................1-800-645-7492 (8 a.m.-8 p.m. EST) ATLIS-FAX FAXBACK Automated Fax Retrieval System:..................1-800-573-0153 or ............................................................................................1-516-921-6704 / ext. 1667 World Wide Web Address: .......................................http://www.honeywell.com/security A-1 APPENDIX A Regulatory Agency Statements •••••••••••••••••••••••••••••••••••••••••••••••• • UL Installation Requirements The following requirements apply to both UL Residential and UL Commercial Burglary installations: • All partitions must be owned and managed by the same person(s). • All partitions must be part of one building at one street address. • The audible alarm device(s) must be placed where it/they can be heard by all partitions. • The control cabinet must be protected from unauthorized access. This can be done by installing a tamper switch on the cabinet door (not supplied with VISTA-128BP/VISTA-250BP) or by installing a UL Listed passive infrared detector positioned to detect cabinet access. Wire the selected device to any EOLR-supervised zone (Zone 1-8). Program this zone for day trouble/night alarm (type 05) or 24-hour audible alarm (type 07) response. The 24-hour alarm response must be used for multiple-partitioned systems. • Remote downloading and auto-disarming are not UL Listed features. NOTE: UL Commercial Burglary installations require the attack resistant cabinet. The cabinet is included in the VISTA-ULKT kit. UL609 Grade A Local Mercantile Premises/Local Mercantile Safe & Vault Use the following guidelines for a Grade A Local Mercantile Premises/Local Mercantile Safe & Vault installation: • All zones must be configured for EOLR supervision (✳41=0). Wireless sensors may not be used. If 4190WH RPMs are used, set field ✳24 to “0” to enable tamper detection. • Attach a door tamper switch (supplied) to the VISTA-128BP/VISTA-250BP cabinet backbox. For safe and vault installations, a shock sensor (not supplied) must also be attached to the backbox. (Also see SECTION 3: Installing the Control) • Wire an ADEMCO AB12 Grade A Bell/Box to the bell output. Bell wires must be run in conduit. Program the bell output for a timeout of 16 minutes or longer timeout and for confirmation of arming ding. (Also see SECTION 3: Installing the Control.) • Wire the VISTA-128BP/VISTA-250BP tamper switch and AB12 Bell/Box tamper switches to any EOLR-supervised zone (zones 1-8). Program this zone for day trouble/night alarm (type 05) or 24-hour audible alarm (type 07) response. The 24-hour alarm response must be used for multiple-partitioned systems. • Entry delays must not exceed 45 seconds, and exit delays must not exceed 60 seconds. UL365 Police Station Connected Burglar Alarm Follow the instructions for UL609 local installations given above. For Grade A Service: • You may use the VISTA-128BP/VISTA-250BP dialer alone, or the 7720 Long Range Radio alone. • When using the dialer, program it to send Burglary Alarm, Low Battery, and Communicator Test reports. Field ✳27 must be set to “0024” (or less). • If you are using the 7720, connect it to the VISTA-128BP/VISTA-250BP burglary/audible panic alarm trigger. For Grade AA Service: • You must use a 7920SE Long Range Radio. • Connect the 7920SE to the VISTA-128BP/VISTA-250BP burglary/audible panic alarm trigger. VISTA-128BP/VISTA-250BP Installation and Setup Guide A-2 UL611/UL1610 Central Station Burglary Alarm Follow the instructions for UL609 Local installations given above. For Grade A Service: • You must use the VISTA-128BP/VISTA-250BP’ dialer with a 7720 Long Range Radio. • Connect the control’s burglary/audible panic alarm trigger (on J7 header) and the 659EN’s phone line monitor output to the 7720. The 7720 will send a report to the central station when a telephone line fault condition is detected. • Also connect the 7720’s radio fault output to one of the VISTA-128BP/VISTA-250BP’ EOLR-supervised zones (i.e., 1-8). Program this zone for a trouble by day/alarm by night (type 05) or a 24-hour alarm (type 07, 08) response to radio faults. • Program the control’s dialer to send Burglary Alarm, Trouble, Opening/Closing, and Low Battery reports. For Grade AA Service: Follow the instructions for Grade A service, except use the 7920SE in place of the 7720. California State Fire Marshal (CSFM) and UL Residential Fire Battery Backup Requirements The California State Fire Marshal and UL have regulations that require all residential fire alarm control panels to have backup battery with sufficient capacity to operate the panel and its attached peripheral devices for 24 hours in the intended standby condition, followed by at least 4 minutes in the intended fire alarm signaling condition. The VISTA-128BP/VISTA-250BP can meet this requirement without using a supplemental power supply, provided that the panel’s outputs (including the current drawn from the auxiliary power output terminals) are limited as shown below: • Output current is limited to 750mA maximum total auxiliary power, polling loop, and bell output current. • Maximum auxiliary current is 300mA (including polling loop current). • A 14AH battery is used. (Yuasa model NP7-12 recommended; use two connected in parallel.) A dual-battery harness is provided with ADEMCO No. 4100EOLR Resistor Kit (kit also contains EOL resistors having spade lug/heat shrink tubing construction approved by UL and CSFM for fire zone usage). Both batteries fit inside the panel’s cabinet. Appendix A – Regulatory Agency Statements A-3 FEDERAL COMMUNICATIONS COMMISSION (FCC) PART 15 STATEMENT NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. IN THE EVENT OF TELEPHONE OPERATIONAL PROBLEMS In the event of telephone operational problems, disconnect the control panel by removing the plug from the RJ31X (CA38A in Canada) wall jack. We recommend that you demonstrate disconnecting the phones on installation of the system. Do not disconnect the phone connection inside the control panel. Doing so will result in the loss of your phone lines. If the regular phone works correctly after the control panel has been disconnected from the phone lines, the control panel has a problem and should be returned for repair. If upon disconnection of the control panel, there is still a problem on the line, notify the telephone company that it has a problem and request prompt repair service. The user may not under any circumstances (in or out of warranty) attempt any service or repairs to the system. It must be returned to the factory or an authorized service agency for all repairs. FCC PART 68 NOTICE This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that contains, among other information, the FCC registration number and ringer equivalence number (REN) for this equipment. If requested, this information must be provided to the telephone company. This equipment uses the following jacks: An RJ31X is used to connect this equipment to the telephone network. The REN is used to determine the quantity of devices that may be connected to the telephone line. Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of the RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to the line, as determined by the total RENs, contact the telephone company to determine the maximum REN for the calling area. If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. If advance notice is not practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe necessary. The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make the necessary modifications in order to maintain uninterrupted service. If trouble is experienced with this equipment, please contact the manufacturer for repair and warranty information. If the trouble is causing harm to the telephone network, the telephone company may request that you remove the equipment from the network until the problem is resolved. There are no user serviceable components in this product, and all necessary repairs must be made by the manufacturer. Other repair methods may invalidate the FCC registration on this product. This equipment cannot be used on telephone company-provided coin service. Connection to Party Line Service is subject to state tariffs. This equipment is hearing-aid compatible. When programming or making test calls to an emergency number, briefly explain to the dispatcher the reason for the call. Perform such activities in the off-peak hours, such as early morning or late evening. VISTA-128BP/VISTA-250BP Installation and Setup Guide A-4 CANADIAN EMISSIONS STATEMENTS This Class B digital apparatus complies with Canadian ICES-003 NOTICE The Industry Canada Label identifies certified equipment. This certification means that the equipment meets telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to the user’s satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may cause the telecommunications company to request the user to disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines, and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Caution: Users should not attempt to make such connections themselves, but should contact an appropriate electric inspection authority, or electrician, as appropriate. NOTICE: The Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5. AVIS L’étiquette d’Industrie Canada identifie le matériel homologué. Cette étiquette certifie que le matériel est conforme aux normes de protection, d’exploitation et de sécurité des réseaux de télécommunications, comme le prescrivent les documents concernant les exigences techniques relatives au matériel terminal. Le Ministère n’assure toutefois pas que le matériel fonctionnera à la satisfaction de l’utilisateur. Avant d’installer ce matériel, l’utilisateur doit s’assurer qu’il est permis de le raccorder aux installations de l’enterprise locale de télécommunication. Le matériel doit également être installé en suivant une méthode acceptée da raccordement. L’abonné ne doit pas oublier qu’il est possible que la conformité aux conditions énoncées ci-dessus n’empêche pas la dégradation du service dans certaines situations. Les réparations de matériel nomologué doivent être coordonnées par un représentant désigné par le fournisseur. L’entreprise de télécommunications peut demander à l’utilisateur da débrancher un appareil à la suite de réparations ou de modifications effectuées par l’utilisateur ou à cause de mauvais fonctionnement. Pour sa propre protection, l’utilisateur doit s’assurer que tous les fils de mise à la terre de la source d’energie électrique, de lignes téléphoniques et des canalisations d’eau métalliques, s’il y en a, sont raccordés ensemble. Cette précaution est particulièrement importante dans les régions rurales. Avertissement : L’utilisateur ne doit pas tenter de faire ces raccordements lui-même; il doit avoir racours à un service d’inspection des installations électriques, ou à un électricien, selon le cas. AVIS : L’indice d’équivalence de la sonnerie (IES) assigné à chaque dispositif terminal indique le nombre maximal de terminaux qui peuvent être raccordés à une interface. La terminaison d’une interface téléphonique peut consister en une combinaison de quelques dispositifs, à la seule condition que la somme d’indices d’équivalence de la sonnerie de tous les dispositifs n’excède pas 5. B-1 APPENDIX B Summary of System Commands ••••••••••••••••••••••••••••••••••••••••••••••••• • User Code Commands Add A User Code = User Code + 8 + New User Number + New User’s Code Change a Code = User Code + 8 + User Number + New User’s Code Delete a User’s Code = Your User Code + 8 + User Number to Be Deleted + Your Code Again View User Capability = User’s Code + [✳] + [✳] Set Real-Time Clock (Installer, Master Only) = Code + [#] + 63 Programming Commands Site Initiated Download = User Code + [#] + 1. Direct-Wire Download Enable = User Code + [#] + 5. Enter Program Mode = Installer Code + 8000. Enter Interactive Program Mode = Installer Code + 8000 + [#] + 93 Exit Program Mode = ✳99 or ✳98. Event Logging Commands Event Log Display = Code + [#] + 60 (Installer or Master Only) Event Log Print = Code + [#] + 61 (Installer or Master Only) Clear Event Log = Code + [#] + 62 (Installer or Master Only) Wireless System Commands House ID Sniffer Mode = Code + [#] + 2 (Installer Only) Transmitter ID Test = Code + [#] + 3 (Installer Only) Go/No Go Test = Code + 5 (Test Key) Partition GOTO User Code + [✳] + Partition Number 0-8. GOTO Home Partition User Code + [✳] + 0. Panics [✳] + 1 or A Key (Zone 995). [✳] + [#] or B Key (Zone 999). [#] + 3 or C Key (Zone 996). View Downloaded Messages Press 0 for 5 Seconds. Display All Zone Descriptors Press [✳] for 5 Seconds. Additional Commands Display User Self Help Hold Any Key for 5 Seconds. Output Device Control Commands Activate Output Device as Programmed = User Code + [#] + 71. Activate Output Device as Programmed = User Code + [#] + 72. Activate Output Device Manually = User Code + [#] + 70. Activate Output Device or System Event Instantly = User Code + [#] + 77. Randomize Output Devices = User Code + [#] + 41 Randomize Output Devices Programmed with Activation Times Between 6 PM and 5 AM = User Code + [#] + 42. De-activate Randomization = Enter the sequence used to activate randomization. VISTA-128BP/VISTA-250BP Installation and Setup Guide B-2 Scheduling Commands Installer-Programmed Schedule Events = Installer Code + [#] + 80 (Installer or Master Only). Temporary Schedule Editing = User Code + [#] + 81 (Installer, Master, Manager Only). Extend Closing Window = User Code + [#] + 82 (Installer, Master, Manager Only). End User Output Device Programming = User Code + [#] + 83. Access Control Commands Activate Access Relay for Current Partition = User Code + 0. Request to Enter/Exit = User Code + [#] + 73. Request to Enter/Exit at Access Point = User Code + [#] + 74 + Access Point Number. Change Access Point State = User Code + [#] + 75 + Access Point + State. Perform a Test of the VistaKey Module = Installer Code + [#] + 78. Perform an Access Control Card Function = User Code + [#] + 79. Panel Linking Commands Only user 001 – 050 can perform panel linking. Activate Single-Partition, Single-Panel Mode = User Code + [#] + 86. Exit Single-Partition, Single-Panel Mode = User Code + [#] + 85. Activate Multi-Partition, Multi-Panel Mode = User Code + [#] + 87. Exit Multi-Partition, Multi-Panel Mode = Enter [0]. Activate Multi-Panel View Mode = User Code + [#] + 88. Exit Multi-Panel View Mode = Enter [0]. C-1 APPENDIX C Specifications ••••••••••••••••••••••••••••••••••••••••••••••••• • VISTA-128BP/VISTA-250BP CONTROL Physical: Standard Cabinet (included) 12 1/2" W x 14 1/2" H x 3" D UL Cabinet (optional) 14 1/2" W x 18" H x 4.3" D (Included in the VISTA-ULKT kit) Electrical: Voltage Input: From ADEMCO No. 1361 Plug-In Transformer (use 1361CN in Canada) or 1361X10 transformer (for X-10 installations) rated 16.5VAC, 40 VA. Alarm Sounder Output: 10VDC-13.8VDC, 1.7 amps max. (UL1023, UL609 installations); 750mA less aux. current draw (UL985 installations). Auxiliary Power Output: 9.6VDC-13.8VDC, 750mA max. For UL installations, the accessories connected to the output must be UL Listed, and rated to operate in the above voltage range. Backup Battery: 12VDC, 4AH or 7AH gel cell. YUASA NP4-12 (12V, 4AH) or NP7-12 (12V, 7AH) recommended. Standby Time: 4 hours min. with 750 mA aux. load using 7 AH battery. Circuit Protectors: PTC circuit breakers are used on battery input to protect against reverse battery connections and on alarm sounder output to protect against wiring faults (shorts). A solid-state circuit breaker is used on auxiliary power output to protect against wiring faults (shorts). Digital Communicator Formats Supported: ADEMCO High Speed, ADEMCO 4 + 2 Express, ADEMCO Low Speed, ADEMCO Contact ID, Sescoa and Radionics Low Speed Line Seize: Double Pole Ringer Equivalence: 0.7B FCC Registration No.: AC398U-68192-AL-E Remote Keypads 6139 Physical: Width: 6.25 inches Height: 4.75 inches Depth: 1.25 inches Electrical: Voltage Input: 12VDC Current Drain: 100mA Interface Wiring: RED: 12VDC input (+) auxiliary power BLUE: Not Used GREEN: Data to control panel YELLOW: Data from control panel BLACK: Ground and (-) connection from supplemental power supply 6160 Physical: Width: 7.437 inches Height: 5.25 inches Depth: 1.312 inches Electrical: Voltage Input: 12VDC Current Drain: 150mA Interface Wiring: RED: 12VDC input (+) auxiliary power BLUE: Not Used GREEN: Data to control panel VISTA-128BP/VISTA-250BP Installation and Setup Guide C-2 YELLOW: Data from control panel BLACK: Ground and (-) connection from supplemental power supply 6160V Physical: Width: 7 3/8 inches Height: 5 5/16 inches Depth: 1 3/16 inches Electrical: Voltage Input: 12VDC Current Drain: 190mA Interface Wiring: RED: 12VDC input (+) auxiliary power BLUE: Not Used GREEN: Data to control panel YELLOW: Data from control panel BLACK: Ground and (-) connection from supplemental power supply D 1 APPENDIX D Contact ID and Pager Event Codes ••••••••••••••••••••••••••••••••••••••••••••••••• • TABLE OF CONTACT ID EVENT CODES Code Definition 110 FireAlarm 111 SmokeAlarm 121 Duress 122 SilentPanic 123 AudiblePanic 124 DuressAccessGrant 125 DuressEgressGrant 131 PerimeterBurglary 132 InteriorBurglary 133 24-HourBurglary 134 Entry/ExitBurglary 135 Day/NightBurglary 140 ACSZoneAlarm 150 24-HourAuxiliary 301 ACLoss 302 LowSystem Battery 305 SystemReset 306 ProgramTamper 308 SystemShutdown 309 BatteryTestFail 313 SystemEngineerReset 320 ACSRelaySupervision 321 Bell1Trouble 332 PollLoop Short-Trouble 333 ExpansionModuleFailure 338 ACSModuleLowBattery 339 ACSModuleReset 342 ACSModuleACLoss 343 ACSModuleSelf-TestFail 354 ACSRS232Fail 373 FireLoop Trouble 378 CrossZoneTrouble 380 Trouble(global) 381 LossofSupervision(RF) 382 LossofRPMSupervision 383 RPMSensorTamper 384 RFTransmitterLowBattery 389 DetectorSelf-TestFailed 401 O/CbyUser 403 Power-Up Armed/Auto-Arm 406 CancelbyUser 407 RemoteArm/Disarm(Download) CodeDefinition 408 QuickArm 409 KeyswitchO/C 411 CallbackRequested 421 AccessDenied 422 Access Granted 423 DoorForceOpen 424 EgressDenied 425 EgressGranted 426 DoorProp Open 427 AccessPointDSMTrouble 428 AccessPointRTETrouble 429 ACSProgramEntry 430 ACSProgramExit 431 ACSThreatChange 432 AccessPointRelay/TriggerFail 433 AccessPointRTEShunt 434 AccessPointDSMShunt/Unshunt 441 ArmedSTAY 451 EarlyOpen/Close 452 LateOpen/Close 453 FailtoOpen 454 FailtoClose 455 Auto-ArmFail 457 ExitErrorbyUser 459 RecentClose 501 ACSReaderDisable 520 ACSRelayDisable 570 Bypass 576 ACSZoneShunt 577 ACSPointBypass 579 VentZoneBypass 602 CommunicatorTest 606 Listen-IntoFollow 607 BurglaryWalk-Test 621 EventLogReset 622 EventLog50%Full 623 EventLog90%Full 624 EventLogOverflow 625 Time/DateReset 631 ExceptionScheduleChange 632 AccessScheduleChange Event Log and Pager Alpha Descriptors Alpha Event Description FIRE Fire Alarm DURESS Duress Alarm PANIC Silent or Audible Panic Alarm BURGLARY Burglary Alarm EXP SHRT Polling Loop Short RF EXPND Expander Module Failure AUXILIARY Non-burglary Alarm TROUBLE Trouble AC LOSS AC Loss LOW BATTERY System Low Battery SYSTEM RESET System Reset PROG CHANGE Program Change BATTERY FAIL System Battery Failure RF SUPR RF Supervision RPM SUPR RPM Supervision Alpha Event Description RF LBAT RF Low Battery EXP TRBL Expander Module Trouble RF TRBL RF Trouble TAMPER Tamper FIRE TRB Fire Trouble FAIL TO COMM Failure to Communicate BELL TROUBLE Bell Trouble DISARMED Disarmed DISARMED-REM Disarmed Remotely DISARMED-KEY Disarmed Via RF Key DISARM-AUTO Auto-Disarm CALL BACK Callback Requested CANCEL Cancel VISTA-128BP/VISTA-250BP Installation and Setup Guide D 2 DISRMD-EARLY Disarmed Early DISRMD-LATE Disarmed Late Alpha Event Description MISSED DISRM Missed Disarm SKED CHANGE Schedule Change ACC SKED CHG Access Control Schedule Change ARM FAILED Failed to Arm DIALER SHUT Dialer Shutdown SYSTEM SHUT System Shutdown BYPASS Bypass SELF TEST Self-test TEST ENTRY Manual Test Entry TEST EXIT Manual Test Exit LOG 50% FULL Event Log 50% Full LOG 90% FULL Event Log 90% Full LOG OVERFLOW Event Log Overflow LOG CLEARED Event Log Cleared TIME SET Time Set TIME ERROR Time Error PROGRM ENTRY Program Entry PROGRAM EXIT Program Exit Uxxx ADD BY User XXX Added BY Uxxx DEL BY User XXX Deleted BY Uxxx CHG BY User XXX Changed BY PRINTER FAIL Event Log Printer Failure PAGER FAILED Pager Failure TESTED Zone Tested UNTESTED Zone Untested FAILED Zone Test Failed RLY TRBL Relay Trouble EXP TMPR Expansion Module Tamper VENT BYPASS Vent Zone Bypass RF JAM RF Jam Detected JAM RSTR RF Jam Restore FIRE RST Fire Alarm Restore DURE RST Duress Alarm Restore PNC RST Panic Alarm Restore BURG RST Burglary Alarm Restore EXP RST Expansion Module Restore RF RST RF Restore AUX RST Auxiliary Restore MED RST Medical Restore TRBL RST Trouble Restore AC RESTORE AC Restore LOW BATT RST System Low Battery Restore PROG CHANGE Program Change BAT TST FAIL Battery Test Failure RPM RST RPM Restore RFLB RST RF Low Battery Restore EXP RST Expansion Module Failure Restore TMPR RST Tamper Restore FRTR RST Fire Trouble Restore COMM RESTORE Communication Restore RLY RST ECP Relay Trouble Restore ARMED Armed ARMED-STAY Armed Stay ARMED-REM Armed Remotely ARMED-QUICK Quick Armed ARMED-KEY Armed Via RF Key ARMED-AUTO Auto-Armed PARTIAL ARM Partial Armed ARMED-EARLY Armed Early ARMED-LATE Armed Late MISSED ARM Missed Arm DIALER RST Dialer Restore (Shutdown) SYSTEM RST System Restore (Shutdown) Alpha Event Description BYP RST Bypass Restore TEST EXIT Test Mode Exit PRINTER RSTR Printer Restore PAGER RSTR Pager Restore BELL RESTORE Bell Restore EXIT ERR Exit Error RECENT ARM Recent Arm VENT BYP RST Vent Zone Bypass Restore Access Control Events ACS MOD VGM/Access Control Module Failure ACS PNT Access Point Failure DSM SHNT Door Status Monitor Shunt DUR ACCS Duress Access Grant NO ENTRY Access Denied DR OPEN Door Propped Open DR FORCE Door Forced Open ENTERED Access Granted NO EXIT Egress Denied ACPT BYP Access Point Bypass RTE SHNT Request to Exit Shunt EXITED Egress Granted ACLO MOD AC Loss at Module LBAT MOD Low Battery at Module COMM MOD Comm Failure from MLB to Module RES MOD Access Control Module Reset ACPT RLY Access Point Relay Supervision Fail SELF MOD Module Self-Test Failure ACZN CHG Access Control Zone Change ACS PROG Access Control Program Entry ACS PRGX Access Control Program Exit THRT CHG Access Control Threat Change SYS SHUT System Shutdown SYS RST System Engineer Reset ZN SHUNT Access Control Zone Shunt ZN ALARM Access Control Zone Alarm RDR DISA Access Control Reader Disable RLY DISA Access Control Relay/Trigger Disable RTE TRBL Request to Exit Point Trouble DSM TRBL Door Status Monitor Point Trouble DUR EXIT Duress Egress Grant BGN ACS TEST Access Control Test Mode Start MOD RST VGM/Access Control Module Restore ACPT RST Access Point Restore ACRST MOD AC Loss at Module Restore LBAT RST Low Battery at Module Restore COMM RST Comm Fail MLB to Module Restore RLY RST Access Point Relay Supervision Rest SELF RST Self-Test at Module Restore ACPT UNB Access Point Unbypass DSM UNSH Door Status Monitor Unshunt RTE UNSH Request to Exit Point Unshunt DRFO RST Door Forced Open Restore DRPO RST Door Propped Open Restore DSM RST Door Status Monitor Trouble Restore RTE RST Request to Exit Point Trouble Rest RLY ENAB Access Control Relay/Trigger Enable RDR ENAB Access Control Reader Enable ZNAL RST Access Control Zone Restore ZN UNSHT Access Control Zone Unshunt SYSHTRST System Shutdown Restore END ACS TEST Access Control Test Mode End Id 1 Index ••••••••••••••••••••••••••••••••••••••••••••••••• • #93 Menu Mode Programming ..................................4-2 #93 Menu Mode Programming Commands................4-4 12/24 Hour Type Stamp Format..............................5-12 1361 ................................................................3-35, C-1 24-hour Audible Alarm Type 07 .................................4-6 24-hour Auxiliary Alarm Type 08................................4-6 24-hour Silent Alarm Type 06....................................4-6 2-Wire Latching Glassbreak Detectors....................3-10 2-Wire Smoke Detectors...........................................3-7 333 PRM...................................................................3-8 4100SM ...........................................................3-27, 4-9 4100SM Serial Module ..............................................7-4 4101SN Relay Modules...........................................3-18 4197 Polling Loop Extender.....................................3-12 4204 and 4204CF Relay Modules............................3-17 4285/4286 VIP Module............................................3-28 4297 Polling Loop Extender.....................................3-12 4300 transformer ....................................................3-35 4300 Transformer ..........................................3-18, 3-35 4-Wire Smoke Detectors...........................................3-7 5800 Series Transmitters ........................................3-15 5800TM Module......................................................3-15 5869 ................................................................1-2, 3-13 5881 RF Receivers .................................................3-14 5881ENHC.......................................................1-2, 3-13 6139 ........................................................................C-1 6160 ........................................................................C-1 6160V......................................................................C-2 675 Ground Start Module........................................3-18 719...........................................................................3-4 747...........................................................................3-4 7720 .......................................................................3-22 7720ULF.................................................................3-22 7920SE...................................................................3-22 A AAV........................................................................3-30 ABB1031 ..................................................................3-4 AC 60Hz or 50Hz....................................................5-11 AC Loss Keypad Sounding........................................5-2 AC Outlet Ground ...................................................3-36 Access Group..........................................................9-3 Access Control........................................3-25, 3-26, 4-9 Access Control Commands................................6-8, B-2 Access Control Dialer Enables ................................5-10 Access Control of an Entry/Exit Point........................4-9 Access Control of Lighting and Appliances ..............4-10 Access Control Using RF Transmitter......................4-10 ACCESS GRP PGM..................................................4-3 ACCESS POINT PGM ..............................................4-3 Access Point Type 27................................................4-7 Access Relay Number.............................................5-12 Access Schedules.....................................................6-5 Action Code..............................................................6-8 Action Specifier.........................................................6-8 Activation Time.........................................................6-9 Adding a User Code..................................................9-3 Adding an RF Key to a User Code............................9-4 Addressing the Keypads ...........................................3-3 ADEMCO 4+2 Express.............................................3-5 ADEMCO 4+2 EXPRESS..........................................C-1 ADEMCO 4146.......................................................3-19 ADEMCO 685 receiver..............................................3-5 ADEMCO 685 Receiver ..........................................3-30 Ademco AB12...........................................................3-1 ADEMCO CONTACT ID............................................C-1 ADEMCO HIGH SPEED ...........................................C-1 ADEMCO Low Speed ...............................................3-5 ADEMCO LOW SPEED............................................C-1 Affects Lobby.....................................................2-2, 5-7 Agency Statements...................................................A-1 Alarm Output Current Load .....................................3-37 Alarm Output Supervision .........................................3-4 Allow Disarm Outside Window if Alarm Occurs........5-13 Allow Disarming Only During Arm/Disarm Windows.5-13 Alpha Pager Module ........................................3-23, 4-8 ALPHA PROG..........................................................4-3 Antenna Fault .........................................................3-23 Arm/Disarm Commands............................................6-8 Arm-Away Type 21...................................................4-7 Arms Lobby .......................................................2-2, 5-8 Arm-STAY Type 20...................................................4-7 Audio Alarm Verification Module..............................3-30 Auto Arming..............................................................6-1 Auto Disarming.........................................................6-1 Auto-Arm Delay...............................................5-13, 6-1 Auto-Arm Warning....................................................6-1 Auto-Arm Warning Period.......................................5-13 Auto-Disarm Delay..................................................5-13 AUXILIARY OUTPUT ENABLE......................3-18, 3-20 Auxiliary Output Mode.............................................5-11 Auxiliary Power Current Load..................................3-36 B BACK-UP BATTERY.................................................C-1 Battery Capacity Worksheet....................................3-37 Battery Selection Table...........................................3-38 Battery Test............................................................10-1 Bell Timeout..............................................................5-2 Burglary Alarm Communicator Delay.........................5-7 Burglary or RS232 Input............................................5-2 Burglary Trigger for Response Type 8.......................5-3 Burglary Walk Test.................................................10-1 Button RF...............................................................3-16 Button RF (BR) Type 05............................................4-7 Bypass Commands...................................................6-8 C Cabinet Lock.............................................................3-1 California State Fire Marshal (CSFM)........................A-2 Call Waiting Defeat.................................................5-10 Callback....................................................................7-3 Callback Requested..................................................7-1 CANADIAN EMISSIONS STATEMENTS...................A-4 Cancel Verify............................................................5-7 Changing a User Code..............................................9-4 Check Messages ....................................................10-3 Check or TBLE Display.............................................5-7 Checksum Verification...............................................5-5 Chime on External Siren..........................................5-11 CIRCUIT PROTECTORS.........................................C-1 Code + TEST [5].....................................................10-1 Cold Water Pipe......................................................3-36 COMM FAILURE....................................................10-3 Common Lobby.........................................................2-1 Communication Defaults...........................................4-4 Communicator Split Reporting Selection..................5-10 Compass Downloading Software...............................7-4 COMPASS downloading software .............................7-1 Compatible 2-Wire Smoke Detectors.........................3-7 Compatible 4-Wire Smoke Detectors.........................3-7 Compatible 5800 Series Transmitters......................3-16 Compatible Alarm Indicating Devices.........................3-4 Compatible Glass Break Detectors..........................3-10 Compatible Polling Loop Devices.............................3-11 Confirmation of Arming Ding......................................5-2 Console Input (CS) Type 09......................................4-8 Contact ID.................................................................1-3 CONTACT ID EVENT CODES .................................D-1 Contacting Technical Support..................................10-4 Control Unit Power Supply Load..............................3-36 Conventions Used in This Manual ................................vi Cross Zoning Pair Four.............................................5-9 Cross Zoning Pair One..............................................5-9 Cross Zoning Pair Three...........................................5-9 Cross Zoning Pair Two..............................................5-9 Cross-Zoning............................................................5-8 CUSTOM INDEX.......................................................4-3 D Data Encryption........................................................7-1 Data Field Descriptions.............................................5-1 Data Field Programming Mode..................................4-1 Daylight Saving Time Start/End Month....................5-12 Daylight Saving Time Start/End Weekend...............5-12 Deleting a User Code................................................9-4 DEVICE PROG.........................................................4-3 Dial Tone Detection...................................................5-5 Dial Tone Pause........................................................5-5 Dialer Test..............................................................10-1 DIGITAL COMMUNICATOR.....................................C-1 DIP Switch Loop (DP) Type 07..................................4-8 Direct-Wire Downloading...........................................7-4 Disable Download Callback .....................................5-11 Disarm Delay............................................................6-1 Disarm Type 22........................................................4-7 Display Burglary & Panic Alarms for Other Partitions5-14 Display Fire Alarms of Other Partitions....................5-14 Display Troubles of Other Partitions ........................5-14 Door Status Monitor (DSM) Type 11.........................4-8 Download Command Enables ...................................5-4 Download ID Number................................................5-4 Download Phone Number .........................................5-4 Downloading.............................................................7-1 Downloading Access Security ...................................7-1 Downloading Requirements ......................................7-1 Dual Reporting..........................................................5-6 Duress Codes Level 6...............................................9-2 Duress Reporting......................................................9-2 Dynamic Signaling Delay..................................3-22, 5-6 Dynamic Signaling Priority................................3-22, 5-6 E Early Power Detect.................................................3-23 Earth Ground..........................................................3-36 ECP Wire Run........................................................3-21 Enable 5800 RF Button Force Arm..........................5-11 Enable 5800 RF Button Global Arm.........................5-11 Enable Dialer Reports for Panics & Duress ...............5-7 Enable GOTO for this Partition................................5-13 Enable J7 Triggers for Partition...............................5-13 Enable Open/Close Report for Installer Code ............5-4 Enable Open/Close report for Keyswitch...................5-5 Enable Random Timers For Partitions 1-8.................5-1 Entering Programming Mode....................................4-1 Entry Delay #1..........................................................5-2 Entry Delay #2..........................................................5-2 Entry Warning...........................................................5-7 Entry/Exit #1 Type 01................................................4-6 Entry/Exit #2 Type 02................................................4-6 event log........................................................3-23, 3-27 Event Log...................................................1-4, 4-8, 4-9 Event Log and Pager Alpha Descriptors....................D-1 Event Log Printer On-Line Mode.............................5-12 Event Log Types.....................................................5-12 Event Logging Commands........................................B-1 EVENT/ACTION PGM ..............................................4-3 Exception Reports ....................................................6-2 Exit Delay #1............................................................5-2 Exit Delay #2............................................................5-2 Exit Delay Sounding................................................5-11 Exit Error..................................................................1-3 Exit Error Logic Enable .............................................5-8 Exiting the User Edit Mode........................................9-4 EXPERT MODE........................................................4-3 Extend Closing Window ............................................6-1 External Sounders ....................................................3-4 F FCC Part 15 STATEMENT........................................A-3 FCC PART 68 NOTICE.............................................A-3 FCC REGISTRATION NO.........................................C-1 Fire Display Lock......................................................5-7 VISTA-128BP/VISTA-250BP Installation and Setup Guide Index-D-2 Fire With Verification Type 16....................................4-7 First Communication.................................................7-3 First Test Report Time ..............................................5-6 Force Arm.................................................................6-1 Force Arm Enable for Auto-Arm ..............................5-13 Frwd. Power Loss...................................................3-23 FSA Modules ..........................................................3-17 G General Description ..................................................1-1 General Purpose (GP) Type 13.................................4-8 Getting On-Line with a Control Panel.........................7-3 Global Arm ?.............................................................9-3 Go/No Go Test Mode..............................................10-2 Grade A Mercantile Premises Listing.........................3-1 Grade A Mercantile Safe and Vault Listing.................3-2 Grade A Service................................................A-1, A-2 Grade AA Service .............................................A-1, A-2 Ground Start Module...............................................3-18 H Hardwire and Optional Expansion Zones...................1-2 Hardwired (HW) Type 01...........................................4-7 Holiday Schedule ......................................................6-3 Holiday Schedule Programming.................................6-7 Holiday schedules.....................................................6-4 Holiday Schedules.....................................................6-6 Home Automation..........................................3-24, 3-27 House ID Sniffer Mode............................................3-15 How to Use Panel Linking..........................................B-2 I Ignore Expansion Zone Tamper ................................5-3 Installer (User 1) Code Level 0 ..................................9-1 Installer Code............................................................5-1 Installer Unattended Program Mode ..........................7-2 Installing RPM Devices............................................3-11 Installing The Control................................................3-1 Installing the Control's Circuit Board..........................3-2 Intelligent Test Report...............................................5-3 Interior w/Delay Type 10...........................................4-7 Interior, Follower Type 04..........................................4-6 K Keypad Panic Enables ..............................................5-3 Keypads....................................................................2-1 Keyswitch...............................................................3-19 Keyswitch Assignment..............................................5-2 Keyswitch Tamper...................................................3-19 L Limitation of Access..................................................6-2 Limitation of Access Schedules ...............................6-11 Limitation Of Access Schedules Programming.........6-12 LINE SEIZE..............................................................C-1 List of Figures...............................................................v LO BAT..................................................................10-3 Lobby Partition..........................................................5-7 Long Range Radio Central Station #1 Category Enable..................................................................5-6 Long Range Radio Central Station #2 Category Enable..................................................................5-6 Long Range Radio ECP..........................................4-10 Long Range Radio to ECP......................................3-22 Long Range Radio to J7 Triggers............................3-22 Low Speed Format (Primary)....................................5-5 Low Speed Format (Secondary)................................5-5 LRR Battery............................................................3-23 LRR CRC is bad .....................................................3-23 LRR reporting options .............................................3-22 LRR Trouble Messages ..........................................3-23 M Main Logic Board....................................................3-27 Main Logic Board Supervision Type 28 .....................4-7 Manager Codes Level 2............................................9-1 Master Codes Level 1...............................................9-1 Master Keypad.........................................................2-3 MODEM COMM..............................................7-1, 10-3 modems ...................................................................7-1 Momentary Exit Type 29...........................................4-7 Mounting The Control Cabinet...................................3-1 Multi-Access ?..........................................................9-3 Multi-Panel View Mode .............................................2-6 Multi-Partition Multi-Panel Mode................................2-6 Multiple Alarms.........................................................5-3 Multiple Partition Access...........................................9-2 N No Alarm Response Type 23 ....................................4-7 Non-UL Installations..................................................3-4 Normally Closed or EOLR (Zones 2-8)......................5-5 Number of Partitions...............................................5-12 O OC or OPEN CIRCUIT..............................................3-3 On-Line Control Functions........................................7-3 Open/Close Reporting...............................................9-2 Open/Close Reports by Exception....................5-13, 6-3 Open/Close Schedule...............................................6-3 Open/Close Schedule Programming .........................6-6 Open/Close Schedules ......................................6-4, 6-6 Open/Close Windows................................................6-8 Operator Access Levels............................................7-1 Operator Codes Levels 3-5 .......................................9-1 Output Device Control Commands ............................B-1 Output Devices.......................................................3-17 OUTPUT PGM..........................................................4-3 Overvoltage Protection .............................................3-5 P PA400.......................................................................3-4 PABX Access Code...................................................5-4 Pager 1 Delay 1......................................................5-14 Pager 1 Delay 2......................................................5-14 Pager 1 Format.......................................................5-14 Pager 1 ID Number .................................................5-14 Pager 1 Partition Enable..........................................5-15 Pager 1 Phone Number...........................................5-14 Pager 1 Trigger Event Enables.......................5-15, 5-18 Pager 2 Delay 1......................................................5-15 Pager 2 Delay 2......................................................5-15 Pager 2 Format.......................................................5-15 Pager 2 ID Number .................................................5-15 Pager 2 Partition Enable..........................................5-15 Pager 2 Phone Number...........................................5-15 Pager 2 Trigger Event Enables................................5-15 Pager 3 Delay 1......................................................5-15 Pager 3 Delay 2......................................................5-15 Pager 3 Format.......................................................5-15 Pager 3 ID Number .................................................5-15 Pager 3 Partition Enable..........................................5-16 Pager 3 Phone Number...........................................5-15 Pager 3 Trigger Event Enables................................5-16 Pager 4 Delay 1......................................................5-16 Pager 4 Delay 2......................................................5-16 Pager 4 Format.......................................................5-16 Pager 4 ID Number .................................................5-16 Pager 4 Partition Enable..........................................5-16 Pager 4 Phone Number...........................................5-16 Pager 4 Trigger Event Enables................................5-16 Pager 5 Delay 1......................................................5-16 Pager 5 Delay 2......................................................5-16 Pager 5 Format.......................................................5-16 Pager 5 ID Number .................................................5-16 Pager 5 Partition Enable..........................................5-17 Pager 5 Phone Number...........................................5-16 Pager 5 Trigger Event Enables................................5-17 Pager 6 Delay 1......................................................5-17 Pager 6 Delay 2......................................................5-17 Pager 6 Format.......................................................5-17 Pager 6 ID Number .................................................5-17 Pager 6 Partition Enable..........................................5-17 Pager 6 Phone Number...........................................5-17 Pager 6 Trigger Event Enables................................5-17 Pager 7 Delay 1......................................................5-17 Pager 7 Delay 2......................................................5-17 Pager 7 Format.......................................................5-17 Pager 7 ID Number .................................................5-17 Pager 7 Partition Enable..........................................5-17 Pager 7 Phone Number...........................................5-17 Pager 7 Trigger Event Enables................................5-18 Pager 8 Delay 1......................................................5-18 Pager 8 Delay 2......................................................5-18 Pager 8 Format.......................................................5-18 Pager 8 ID Number .................................................5-18 Pager 8 Partition Enable..........................................5-18 Pager 8 Phone Number...........................................5-18 Pager Formats........................................................3-24 Pager Installed........................................................5-14 Paging Service........................................................3-23 Panel Link Module ...........................................2-4, 3-21 Panel Link Module Supervision .................................2-4 Panel Linking.......................................1-3, 2-1, 2-4, 4-8 Panel Linking Commands .........................................B-2 panel linking users.............................................2-4, 9-1 Panic Button or Speedkey.........................................5-9 Partitioned System....................................................2-1 Partitioning........................................................1-3, 2-1 PassPoint Access Control (ACS) Type 10.................4-8 PassPoint Access Control System..........................3-26 PassPoint Dialer Events............................................4-9 Perimeter Type 03....................................................4-6 Peripherals Devices ..................................................1-2 Permanent Keypad Display Backlighting .................5-10 Phone Module Access Code .....................................5-3 PLL out of Lock.......................................................3-23 PLM..........................................................................2-4 polling loop.............................................................3-11 Polling Loop Current Draw ......................................3-36 Polling Loop Supervision.........................................3-12 Power Failure.........................................................10-3 Power Unattained...................................................3-23 Power-Up in Previous State......................................5-3 Prevent Fire Timeout ................................................5-3 Prevent Zone XXX Bypass........................................5-4 Primary Format.........................................................5-5 Primary Phone Number.............................................5-4 Primary Subscriber’s Account Number......................5-4 Printer Baud Rate ...................................................5-12 Printer Configurations.............................................3-27 Printer Type............................................................5-12 Priority of Displays for Panel Linking .........................2-7 Program Modes........................................................4-1 Programming Commands .........................................B-1 PROGRAMMING COMMANDS................................4-1 Programming Entry Errors........................................4-2 Programming Overview.............................................4-1 Programming Partition-Specific Data Fields...............4-2 Programming Scheduling Options.............................6-4 Programming System-Wide Data Fields....................4-2 Q Quick Arm.........................................................5-3, 9-1 Quick Exit.................................................................5-1 R RADIONICS LOW SPEED........................................C-1 Random time............................................................6-9 Randomize AC Loss Report......................................5-2 RCVR SETUP ERROR...........................................10-3 Real-Time Clock.......................................................8-1 Recent Close............................................................1-3 Refresh Feature........................................................6-7 Regulatory Agency Statements.................................A-1 Relay commands......................................................6-8 Relay Timeout XXX Minutes....................................5-12 Relay Timeout YYY Seconds ..................................5-12 VISTA-128BP/VISTA-250BP Installation and Setup Guide Index-D-4 Remote Keypad Sounder........................................3-20 REPORT CODE PROG.............................................4-3 Reporting Formats ....................................................3-5 Request to Exit (RTE) Type 12..................................4-8 Restore Report Timing ..............................................5-7 Restrict Disarming.....................................................6-1 RF Motion (RM) Type 02..................................3-16, 4-7 RF Receiver Supervision Check-in Interval..............5-10 RF System Installation Advisories............................3-14 RF System Operation and Supervision....................3-13 RF Transmitter Check-in Interval.............................5-10 RF Transmitter Low Battery Reporting.....................5-10 RF Transmitter Low Battery Sound............................5-9 Ring Detection Count .........................................5-5, 7-3 RINGER EQUIVALENCE.........................................C-1 RJ31X jack.......................................................3-5, 3-29 RLY VOICE DESCR..................................................4-3 RS-485 Bus .....................................................2-4, 3-21 RTE..........................................................................4-8 S Scheduled Check-in..................................................7-4 Scheduled Download.................................................7-4 Scheduling................................................................6-1 Scheduling Commands .............................................B-2 Scheduling Menu Mode.............................................6-4 Secondary Format ....................................................5-5 Secondary Phone Number ........................................5-4 Secondary Subscriber Account Number ....................5-7 Send Cancel If Alarm + Off......................................5-11 Send Message to Pager After Dialer........................5-14 Serial Number Devices............................................3-12 Serial Number Polling Loop (DS) Type 08..................4-8 Serial Number Polling Loop (SL) Type 06 ..................4-8 Serial Printer..................................................3-24, 3-27 SESCOA..................................................................C-1 Sescoa/Radionics.....................................................3-5 Sescoa/Radionics Select...........................................5-5 Single-Partition Single-Panel Mode............................2-4 Siren Driver...............................................................3-5 Smoke Detector Reset............................................3-20 Smoke Power Reversal Module.................................3-8 Specifications...........................................................C-1 Standard/Expanded Reporting Primary......................5-6 Standard/Expanded Reporting Secondary.................5-6 Standby Battery Size...............................................3-37 Supervised Fire (Without Verification) Type 09 ..........4-6 Supervised RF (RF) Type 03............................3-16, 4-7 Supervision Pulses for LRR.....................................5-14 Supplementary Power Supply....................................3-3 Suppress Transmitter Supervision Sound................5-11 Swinger Suppression ................................................5-7 System Commands...................................................B-1 System Communication............................................1-3 System Events Notify................................................5-1 SYSTEM LO BAT....................................................10-3 System LoBat”........................................................10-1 System Messages...................................................10-3 System Sensor A77-716B EOL Relay Module ...........3-7 System Sensor MA 12/24D.......................................3-4 System Sensor P12575 ............................................3-4 T Tamper Supervision................................................3-10 TAP protocol...........................................................3-23 Telephone Line Connections.....................................3-5 TELEPHONE OPERATIONAL PROBLEMS..............A-3 TeleSmart...............................................................3-31 Temporary Schedules......................................6-3, 6-12 Temporary Schedules Programming .......................6-13 Test Report Interval ..................................................5-3 Testing The System................................................10-1 Time Driven Events Worksheet.................................6-7 Time to Delay Pager After Dialer.............................5-14 Time Window Definitions...........................................6-2 Time Windows...................................................6-4, 6-5 Time Windows Programming ....................................6-5 Timed Events............................................................6-5 Time-Driven Events...........................................6-2, 6-7 Time-Driven Events Programming.............................6-7 TouchTone or Rotary Dial.........................................5-4 TouchTone with Rotary Backup...............................5-10 Transformer Connections........................................3-35 Transmitter Battery Life...........................................3-16 Transmitter ID Sniffer Mode....................................10-2 Transmitter Input Types..........................................3-16 Transmitter Supervision..........................................3-16 Trouble by Day/Alarm by Night Type 05 ....................4-6 Trouble Conditions..................................................10-3 Trouble Messages ..................................................10-3 Turning the System Over to the User......................10-3 U UL Installation Requirements ....................................A-1 UL1023 Household Burglary Installations ..................3-4 UL365 Police Station Connected Burglar Alarm.........A-1 UL609 Grade A Local Mercantile Premises/Local Mercantile Safe & Vault.........................................A-1 UL611/UL1610 Central Station Burglary Alarm..........A-2 UL985 Household Fire or Household Fire/Burglary Installations...........................................................3-4 UNABLE TO ARM LOBBY PARTITION.....................2-2 Unattended Download...............................................7-1 Unattended Mode .....................................................5-6 Unsupervised RF (UR) Type 04 .......................3-16, 4-7 Use Partition Descriptor..........................................5-13 User Access Codes ..................................................9-1 User Code Authority Levels.......................................9-1 User Code Commands..............................................B-1 User Code Defaults...................................................9-1 User Code Rules ......................................................9-2 User Scheduling Menu Mode ..................................6-14 Users........................................................................2-1 Using ACS Zone Inputs.............................................4-9 V VA8200 ...........................................................2-4, 3-21 VA8201...................................................................3-23 View Capabilities.......................................................9-1 VIP Module.............................................................3-28 VIP Module Phone Code...........................................5-3 VISTA Gateway Module...................................3-27, 4-9 VISTA-128B Plus as Stand-Alone Access Control...4-10 VISTA-128B PLUS Current Load.............................3-37 VistaKey..........................................................3-25, 4-9 VistaKey Dialer Enables............................................4-9 W Wheelock AS-121575W ...........................................3-4 Wire Run Length/Gauge...................................3-3, 3-21 Wireless Keypad Assignment..................................5-11 Wireless Keypad Tamper Detect.............................5-10 Wireless System Commands.....................................B-1 Wireless Zone Expansion........................................3-13 Wiring Devices to Zones 1-9......................................3-6 Wiring the Alarm Output............................................3-4 Wiring the Keypads ...................................................3-3 Worksheets to calculate the total current.................3-36 World Wide Web Address.......................................10-4 X X-10.......................................................................3-18 Y Yuasa.....................................................................3-38 Z Zone 5 Audio Alarm Verification ..............................5-12 Zone 804................................................................3-28 Zone Defaults ...........................................................4-4 Zone Index ...............................................................4-4 Zone Input Type Definitions ......................................4-7 Zone Number Designations.......................................4-4 ZONE PROG........................................................vi, 4-3 Zone Response Type Definitions...............................4-6 Zone Type Restores for Zone Types 1-8...................5-6 Zone Type Restores for Zone Types 9, 10 and 16.....5-6 Zones.......................................................................2-1 WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM While this System is an advanced wireless security system, it does not offer guaranteed protection against burglary, fire or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reasons. For example: • Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor or disconnect an alarm warning device. • Intrusion detectors (e.g., passive infrared detectors), smoke detectors, and many other sensing devices will not work without power. Battery-operated devices will not work without batteries, with dead batteries, or if the batteries are not put in properly. Devices powered solely by AC will not work if their AC power supply is cut off for any reason, however briefly. • Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm receiver. Even if the signal path has been recently checked during a weekly test, blockage can occur if a metal object is moved into the path. • A user may not be able to reach a panic or emergency button quickly enough. • While smoke detectors have played a key role in reducing residential fire deaths in the United States, they may not acti- vate or provide early warning for a variety of reasons in as many as 35% of all fires, according to data published by the Federal Emergency Management Agency. Some of the reasons smoke detectors used in conjunction with this System may not work are as follows. Smoke detectors may have been improperly installed and positioned. Smoke detectors may not sense fires that start where smoke cannot reach the detectors, such as in chimneys, in walls, or roofs, or on the other side of closed doors. Smoke detectors also may not sense a fire on another level of a residence or building. A second floor detector, for example, may not sense a first floor or basement fire. Finally, smoke detectors have sensing limitations. No smoke detector can sense every kind of fire every time. In general, detectors may not always warn about fires caused by carelessness and safety hazards like smoking in bed, violent explosions, escaping gas, improper storage of flammable materials, overloaded electrical circuits, children playing with matches, or arson. Depending on the nature of the fire and/or location of the smoke detectors, the detector, even if it operates as anticipated, may not provide sufficient warning to allow all occupants to escape in time to prevent injury or death. • Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation manual. Passive Infrared Detectors do not provide volumetric area protection. They do create multiple beams of protection, and intrusion can only be detected in unobstructed areas covered by those beams. They cannot detect motion or intrusion that takes place behind walls, ceilings, floors, closed doors, glass partitions, glass doors, or windows. Mechanical tampering, masking, painting or spraying of any material on the mirrors, windows or any part of the optical system can reduce their detection ability. Passive Infrared Detectors sense changes in temperature; however, as the ambient temperature of the protected area approaches the temperature range of 90° to 105°F (32° to 40°C), the detection performance can decrease. • Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are located on the other side of closed or partly open doors. If warning devices are located on a different level of the residence from the bed- rooms, then they are less likely to waken or alert people inside the bedrooms. Even persons who are awake may not hear the warning if the alarm is muffled by noise from a stereo, radio, air conditioner or other appliance, or by passing traffic. Finally, alarm-warning devices, however loud, may not warn hearing-impaired people. • Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service or temporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders. • Even if the system responds to the emergency as intended, however, occupants may have insufficient time to protect themselves from the emergency situation. In the case of a monitored alarm system, authorities may not respond appropriately. • This equipment, like other electrical devices, is subject to component failure. Even though this equipment is designed to last as long as 20 years, the electronic components could fail at any time. The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance. This alarm system should be tested weekly to make sure all sensors and transmitters are working properly. The security keypad (and remote keypad) should be tested as well. Wireless transmitters (used in some systems) are designed to provide long battery life under normal operating conditions. Longevity of batteries may be as much as 4 to 7 years, depending on the environment, usage, and the specific wireless device being used. External factors such as humidity, high or low temperatures, as well as large swings in temperature, may all reduce the actual battery life in a given installation. This wireless system, however, can identify a true low battery situation, thus allowing time to arrange a change of battery to maintain protection for that given point within the system. Installing an alarm system may make the owner eligible for a lower insurance rate, but an alarm system is not a substitute for insurance. Homeowners, property owners and renters should continue to act prudently in protecting themselves and continue to insure their lives and property. We continue to develop new and improved protection devices. Users of alarm systems owe it to themselves and their loved ones to learn about these developments. LIMITED WARRANTY Honeywell International Inc., acting through its Security & Custom Electronics business ("Seller") 165 Eileen Way, Syosset, New York 11791, warrants its product(s) to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the date stamp control on the product(s) or, for product(s) not having a manufacturer’s date stamp, for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period, in which case the shorter period shall apply. Seller's obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labor, any product(s) which is proved not in compliance with Seller's specifications or proves defective in materials or workmanship under normal use and service. Seller shall have no obligation under this Limited Warranty or otherwise if the product(s) is altered or improperly repaired or serviced by anyone other than Honeywell factory service. Connection of any device(s) to a communicating bus of a Honeywell security system (e.g., keypad bus, polling loop) other than those manufactured or approved by Honeywell shall void this warranty. For warranty service, return product(s) transportation prepaid, to Honeywell Factory Service, 165 Eileen Way, Syosset, New York 11791. THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE OR FAULT. Seller does not represent that the product(s) it sells may not be compromised or circumvented; that the product(s) will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the product(s) will in all cases provide adequate warning or protection. Customer understands that a properly installed and maintained alarm system may only reduce the risk of a burglary, robbery, fire, or other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THAT THE PRODUCT(S) FAILED TO GIVE WARNING. HOWEVER, IF SELLER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN, SELLER'S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT(S), WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER. VISTA-128BP/VISTA-250BP Installation and Setup Guide Index-D-2 This warranty replaces any previous warranties and is the only warranty made by Seller on this product(s). No increase or alteration, written or verbal, of the obligations of this Limited Warranty is authorized. ÊK5894V5%Š K5894V5 6/04 Rev A