HomeMy WebLinkAboutD12-0005TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
DEMO. OF PART /ALL BLDG
Job Address: 1320 WESTHAVEN DR VAIL
Location.......: MILLRACE CONDOMINIUMS UNIT 6C
Parcel No....: 210312111011
OWNER
APPLICANT
CONTRACTOR
GUDMUNDSON 1999 REVOCABLE TR 06/08/2012
22365 REGNART RD
CUPERTINO
CA 95014
SRE BUILDING ASSOCIATES
PO BOX 6376
VAIL
CO 81658
License: C000003460
SRE BUILDING ASSOCIATES
PO BOX 6376
VAIL
CO 81658
License: C000003460
Permit # D12 -0005
Project # ??
Status ...
Applied ...
Issued ...
Expires.....:
ISSUED
06/08/2012
06/11/2012
12/08/2012
06/08/2012 Phone: 970 - 945 -6359
06/08/2012 Phone: 970 - 945 -6359
Desciption:
REMOVAL OF FIRE DAMAGED MATERIAL TO PREPARE FOR REBUILD.
Occupancy:
Type Construction:
Valuation:
$9,000.00
Revision Valuation: ??
Total Sq Ft Added: 0
*********sssssssssssssssssss+++++*+** * + * +
* * * *s + *s *+ *s + * * * * * * +s * * * * ** FEE
SUMMARY s*s*ss******* ssss * *ssssss * *ss +s * * * * * *
* * *s * ** *sss +sss +* *sss **
Building ------ >
$167.25
Restuarant Plan Review - ->
$0.00 Total Calculated Fees - ->
$280.96
Plan Check --- >
$108.71
Recreation Fee--------- - - - - ->
$0.00 Additional Fees ---------- >
$0.00
Investigation ->
$0.00
TOTAL FEES ------------- >
$280.96 Total Permit Fee --------- >
$280.96
Will Call - - - - ->
$5.00
Payments ------------------- >
$280.96
BALANCE DUE --------- >
$0.00
+++s++++ss+++s+++++s+++++**+++ss+s+s+s++*+s++s*******s+*s+s*+++s++s+s+s+s+******+sss+s+s++s++s+** * + * * * *s + +s + +s + + +s + + + + * + * * * + + + ++ +sss + + + + + + + + + + +s+
Approvals:
Item: 05100 BUILDING DEPARTMENT
06/08/2012 JRM Action: AP
Item: 05400 PLANNING DEPARTMENT
Item: 05600 FIRE DEPARTMENT
Item: 05500 PUBLIC WORKS
See the Conditions section of this Document for any conditions that may apply to this permit
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOUR IN AbrANCE BY TELEPHONE AT 479 -2149 OR AT OUR OFFICE FROM 8:00 AM
4 PM. 1 / I A
SIGNA;FME OF )V"ER OR CONTRACTOR FOR HIMSELF AND OWNER
CONDITIONS OF APPROVAL
Permit #: D12 -0005 as of 06 -11 -2012 Status: ISSUED
************************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Permit Type: DEMO. OF PART /ALL BLDG. Applied: 06/08/2012
Applicant: SRE BUILDING ASSOCIATES Issued:
06/11/2012
970 - 945 -6359 To Expire: 12/08/2012
Job Address: 1320 WESTHAVEN DR VAIL
Location: MILLRACE CONDOMINIUMS UNIT 6C
Parcel No: 210312111011
Description:
REMOVAL OF FIRE DAMAGED MATERIAL TO PREPARE FOR REBUILD.
**************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Conditions:***************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Cond: 38
(BLDG.): THIS PERMIT IS GOOD FOR ASBESTOS ABATEMENT ONLY.
AN ASBESTOS ABATEMENT CERTIFICATE SHOWING THE AREA FREE
FROM ASBESTOS IS REQUIRED PRIOR TO ANY FURTHER WORK
OCCURING ON THIS SITE. IF FURTHER QUESTIONS ARISE, CONTACT
THE VAIL FIRE DEPARTMENT AT 479 -2252.
Cond: 1
(FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY
WORK CAN BE STARTED.
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE
COMPLIANCE.
TOWN OF VAIL, COLORADOCopy Reprinted on 06 -11 -2012 at 15:06:35 06/11/2012
Statement
Statement Number: R120000696 Amount: $280.96 06/11/201202:25 PM
Payment Method:Credit Crd Init: DR
Notation: VISA SARAH
WYSCARVER
-----------------------------------------------------------------------------
Permit No: D12 -0005 Type: DEMO. OF PART /ALL BLDG.
Parcel No: 2103 -121- 1101 -1
Site Address: 1320 WESTHAVEN DR VAIL
Location: MILLRACE CONDOMINIUMS UNIT 6C
Total Fees: $280.96
This Payment: $280.96 Total ALL Pmts: $280.96
Balance: $0.00
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------- - - - - -- ------------------------ - - - - -- ------ - - - - --
BP 00100003111100 BUILDING PERMIT FEES 167.25
PF 00100003112300 PLAN CHECK FEES 108.71
WC 00100003112800 WILL CALL INSPECTION FEE 5.00
TOWN Of VA
Department of Community Development
75 South Frontage Road
Vail, CO 81657
Tel: 970 - 479 -2128
www.vailgov.com
ptw "y Development Review Coordinator
PERMIT APPLICATION
(Separate applications are required for alarm & sprinkler)
Project Street Address:
��S r Na ✓E.N �2 .
(Number) (Street)
Building /Complex Name: /1i1TZL eaacji
Contractor Information
(-...L.
(Suite #)
Business Name: .5'K'� ,i30[�L� L�- rJoCist7
Project #: T- K V 1 4, —
Building Permit #: D `a — 000 S
Lot #: Block # Subdivision:
Work Class: New ( ) Addition ( ) Alteration ((�
Business Address: _2`3�`j y U (,W y 2 `t t
City State: GO zip: \ rocs Type of Building:
Contact Name: 111-i ✓z 9
Single - Family ( ) Duplex( ) Multi - Family (t/) t- � -LK�,Q
Commercial ( ) Other( )
Contact Phone: 9? c' 3-7
Contact E -Mail: ,f'TZ,/E 5,ef �u�c�.c�
I Work Type: Interior (V) Exterior ( ) Both ( )
I hereby acknowledge that I have read this application, filled out
in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to
comply with the information and plot plan, to comply with all Town
ordinances and state laws, and to build this structure according to
the town's zoning and subdivision codes, design review ap-
proved, International Building and Residential Codes and other
ordinances of the Town applicable thereto.
X
Owner /Owner's Representative Signature (Required)
Applicant Information
Applicant Name:
Applicant Phone:
Applicant E -Mail:
Project Informatyy'ggn
Owner Name: C %j
Parcel #: ,� i� 3'! a 1— I 1 — 0) 1
(For Parcel #, contact Eagle County Assessors Office at (970- 328 -8640 or visit
www.eaglecounty.us/patie)
For Office Use Only:
Fee Paid:
Received From:
Cash Check #
CC: Visa / MC Last 4 CC #
Auth #
exp date:
Valuation of
Work Included Plans Included Work
i
Electrical ( )Yes ( )No ( )Yes ( )No
Mechanical ( )Yes ( )No ( )Yes ( )No
Plumbing ( )Yes ( )No ( )Yes ( )No
Building (V�es ( )No (--Ife's ( )Nr
Value of all work being performed: $_
J
(value based on IBC Section 109.3 & IRC Section 108.3)
Electrical Square Footage
Detailed Scope and Location of Work:
i
(use additional sheet if
Date Received:
15- Mar -2012
SRE gUtLDING
June 8, 2012
Town of Vail Building Department
Attn: J.R. Mondragon, Senior Building Inspector
Re: Parcel # 2103 - 121 -11 -011, Millrace Unit #6C
Dear J. R.,
In an effort to remediate the smells remaining from the Millrace fire, SRE Building Associates would like to
move forward with interior demolition of Unit #6C immediately.
Our immediate work will include removal of all interior finishes & fixtures, bring the interior building structure
to the framing. Electrical wiring will be evaluated for damage and replaced as needed to regain power to the
unit.
An asbestos test has been obtained and is negative for asbestos containing materials (attached).
A future building permit application will be submitted for the reconstruction of the unit interior.
Please contact me should you have any questions.
Sincerely,
Steve Elicker
President
Meadow Mountain Business Park 23698 HWV 24 Suite D -2 Mintum, CO 81645 PO Box 6376 Vail, CO 81658 Office 970.845.6359 Fax 970.748.6452 SREBuilds.com
Account
Account: RO1O186
Location
Parcel Number 2103 - 121 -11 -011
Tax Area SC 115 - VAIL (TOWN)
- SCI 15
Situs Address 001320
WESTHAVEN DR #6C
Legal Summary Subdivision:
MILLRACE Unit: 6C BK -0342 PG
-0158
R941209 QCD 12 -20-05
R200630442 EAS 11 -06-06
Transfers
Page 1 of 1
Owner Information Assessment History
Owner Name GUDMUNDSON Actual (2012) $1,361,870
1999 REVOCABLE TRUST Primary Taxable $108,400
Owner Address 22365 Tax Area: SC115 Mill Levy: 56.4210
REGNART RD Type Actual Assessed Acres SQFT Units
CUPERTINO, CA 95014
Improvements $1,361,870 $108,400 0.000 1624.000 0.000
Land 0.091 0.000 0.000
Sale Price
Sale Date
$1.675,000
06/03/2008
$1.500,000
12/14/2005
$364,000
09/04/1991
$296,000
07/24/1981
Images
• Photo
• Sketch
Reception Number
200812821
941207
Book Page
B: 0562 P: 0414
B: 03271': 0257
http: / /property.eaglecounty.usl assessor / taxweb laccount.jsp ?accountNum= R010186 6/8/2012
1. Consulting
Asbestos Inspection and Sampling Report
Mill Race Condominiums - Units 6A, 6C and 61)
1376 Westhaven Dr, Vail, Colorado 81657
Presented To:
Mr. Gary Gilman
SteamMaster Restoration & Cleaning, LLC
P.O. Box 399
Minturn, CO 81645
Performed & Prepared By:
Mr. Steve Shurtliff
DS Consulting, Inc.
PO Box 6864
Avon, CO 81620
(303) 378 -1544
Project Details:
Project Number: 5908
Conducted: June 1, 2012
TABLE OF CONTENTS
PROJECT OVERVIEW
1.0 Introduction
2.0 Scope of Work
3.0 Site Description
4.0 Certifications
5.0 Inspection, Sampling & Analytical Procedures
5.1 Inspection Procedures
5.2 Sampling Procedures
5.3 Analytical Procedures
6.0 Homogeneous Areas
6.1 Material Friability
6.2 Material Classifications
6.3 Material Conditions
6.4 Sample Quantities
7.0 Overview of Findings
8.0 Conclusion & Recommendations
9.0 Asbestos Abatement & Demolition Requirements
10.0 Major Asbestos Spill Response
11.0 Disclaimer & Limitations
APPENDIX A Inspector & Firm Asbestos Certificates
APPENDIX B Analytical Data
2
PROJECT OVERVIEW
1.0 Introduction
On June 1, 2012, Mr. Steve Shurtliff with DS Consulting, Inc. (DSC) conducted a limited asbestos
inspection and collected asbestos bulk - samples of suspect asbestos - containing materials (ACM) within a
portion of Units 6A, 6C and 6D of the Mill Race Condominiums located at 1376 Westhaven Dr, Vail,
Colorado.
The purpose of the limited inspection was to identify and sample potentially hazardous friable and non -
friable ACM that has either been affected by a recent fire loss and /or may be impacted by subsequent
restoration activities within each unit.
2.0 Scope of Work
The scope of the limited inspection and bulk - sampling was limited to specific areas of the units defined
by the restoration company. These areas included the drywall within each unit. The remaining areas
within the residence, garage or any out - building on the property were not included in the scope of the
inspection. The limited asbestos inspection did not constitute a full building inspection and does not
fulfill the asbestos inspection requirements for structures that are to be demolished.
3.0 Site Description
The residences are wood - framed, two- level, single- family residences within a multi -unit building. The
units sit over an attached garage.
4.0 Certifications
The limited asbestos inspection and bulk - sampling was conducted by Mr. Steve Shurtliff with DSC. DSC is
a Colorado Department of Public Health and Environment ( CDPHE) certified Asbestos Consulting Firm,
Registration No. 14912. Mr. Shurtliff is a CDPHE certified Building Inspector; having certification number
15413 (see Appendix A for certificates).
5.0 Inspection, Sampling & Analytical Procedures
5.1 Inspection Procedures
The limited asbestos inspection was conducted by an Environmental Protection Agency (EPA) and
CDPHE certified Building Inspector. The inspection procedures included identifying and sampling
suspect ACM within the pre- defined areas, submitting samples to an accredited laboratory for analysis,
classifying the materials and assessing their condition, and compiling a final report detailing the
inspection and the analytical results of the bulk - samples.
5.2 Sampling Procedures
Statistically random bulk - samples representative of the suspect ACM of each homogeneous area were
collected according to the guidelines published as EPA Final Rule: Title II of the Toxic Substances
Control Act (TSCA), 15 USC, Sections 2641 through 2654 and in compliance with 40 CFR, Part 763 and
CDPHE Regulation Number 8, Part B - Asbestos (Reg. 8).
3
DSC has collected the appropriate number of bulk - samples to meet all regulatory requirements for the
classification and quantity of each homogeneous area. Some minor destructive sampling was
conducted; however, walls, columns and perimeter pipe chases were not broken into in order to locate
and quantify suspect ACM. It should be noted that additional ACM might be located in these and other
inaccessible areas.
Materials containing less than 1% asbestos are not regulated by CDPHE Regulation 8, Part B - Asbestos.
However, all demolition /abatement activities should be performed following the applicable
Occupational Safety and Health Administration (OSHA) regulations. This would include, but not limited
to, the appropriate asbestos training for the type of material being removed /disturbed as well as having
a properly trained supervisor onsite, using wet removal methods, wearing adequate personal
protective equipment (HEPA- filtered particulate respirators), medical surveillance of workers,
personal- exposure air monitoring, area air monitoring in occupied buildings, etc. There may also be
landfill disposal requirements for these materials, depending on the facility. DSC recommends that all
demolition /renovation areas involving any amount of asbestos be subjected to visual inspections and a
final clearance air testing by a CDPHE - certified Air Monitoring Specialist (AMS) after the work has been
completed, but before any containments are dismantled and the area is reoccupied.
5.3 Analytical Procedures
All asbestos bulk - samples were analyzed by a National Voluntary Laboratory Accreditation Program
(NVLAP) accredited laboratory via Polarized Light Microscopy (PLM) for asbestos content (see
Appendix B for laboratory report).
The percentage of asbestos within each individual bulk- sample can vary depending on sample location,
homogeneity of the material, and the type of application. Any sample reporting a "TRACE" amount of
asbestos must be considered positive for asbestos greater than 1% unless it is re- analyzed utilizing the
point -count method and verified to be less than 1 %.
6.0 Homogeneous Areas
A Homogeneous Area (HA) includes materials that are uniform in appearance, color, texture and date of
application. The asbestos content of the bulk - samples collected within a homogeneous area can be
applied to the entire homogenous area if they conform to the above characteristics and the regulated
minimum sample quantities of each type of material are collected and analyzed.
6.1 Material Friability
A material can either be friable or non friable. A friable material is one that, when dry, can be
pulverized, or reduced to powder by hand pressure, a non - friable material cannot. A non - friable
material may become friable if its condition had deteriorated or has been impacted by forces that have
rendered it friable.
6.2 Material Classifications
Sampled materials are divided into one of the following three categories:
Surfacing Material: sprayed or troweled onto structural building members
Thermal System Insulation (TSI): any type of pipe, boiler, tank, or duct insulation
Miscellaneous Material: all other materials not classified in the above two categories
4
6.3 Material Conditions
Sampled materials are placed into one of the three following categories of conditions:
• Good: none to very little visible damage or deterioration
• Damaged: the surface is crumbling, blistered, water - stained, gouged, marred or otherwise abraded
over less than one -tenth of the surface if the damage is evenly distributed, or one - quarter if the
damage is localized
• Significantly Damaged: the surface is crumbling, blistered, water - stained, gouged, marred or
otherwise abraded over greater than one -tenth of the surface if the damage is evenly distributed,
or one - quarter if the damage is localized
6.4 Sample Quantities
DSC collected at least the minimum number of samples from each homogeneous area necessary to meet
all regulatory requirements for the quantity of material to be disturbed. The quantities listed in this
report are approximate and on -site verification of the exact quantity of each material is required. The
following outlines the minimum sample quantities required per homogeneous area:
• Surfacing Materials: up to 1,000 ftz of material requires a minimum of three (3) samples; between
1,000 ftz and 5,000 ftz of material requires a minimum of five (5) samples; over 5,000 ftz of
material requires a minimum of seven (7) samples; one (1) sample of each patch
• Thermal System Insulation (TSI): each homogeneous area requires a minimum of three (3)
samples; at least one (1) sample must be collected from each patch; and collect enough samples
sufficient to adequately assess the material and determine the asbestos content for TSI fittings
such as pipe elbows or T's.
• Miscellaneous Materials: collect enough samples sufficient to determine the asbestos content
7.0 Overview of Findings
Asbestos was not reported within any of the bulk - samples collected and analyzed. DSC collected a
total of nine (9) asbestos bulk - samples of three (3) homogeneous areas.
Table 1 below describes the materials composing each homogeneous area as well as the locations of each
bulk - sample collected. Also listed is the classification, condition, friability and estimated quantity of
material to be removed and /or disturbed, as well as the asbestos content within each bulk - sample.
Please see Appendix B: Analytical Data for the layer break -down of each bulk - sample.
5
TABLE 1
HA
Sample
Material
Sample
Material
Material
Estimated
Material
Asbestos
#
ID
Description
Location
Classification
Condition
Quantity
Friability
Content
6A -SM1 -1
Orange Peel Drywall
Kitchen Ceiling
SM
SD
—900 ft2
Friable
ND
Texture
1
6A -SM1 -2
Orange Peel Drywall
Kitchen Ceiling
SM
SD
—900 ft2
Friable
ND
Texture
6A -SM1 -3
Orange Peel Drywall
Kitchen Ceiling
SM
SD
—900 ft2
Friable
ND
Texture
6C -SM1 -1
Orange Peel Drywall
Bedroom Wall
SM
SD
—900 ft2
Friable
ND
Texture
2
6CSM1 -2
Orange Peel Drywall
Living Wall
SM
SD
—900 ft2
Friable
ND
Texture
6CSM1 -3
Orange Peel Drywall
Dining Room Wall
SM
SD
—900 ft2
Friable
ND
Texture
6D -SM1 -1
Orange Peel Drywall
Bedroom Closet Wall
SM
SD
—900 ft2
Friable
ND
Texture
3
6D -SM1 -2
Orange Peel Drywall
Bedroom Closet Wall
SM
SD
—900 ft2
Friable
ND
Texture
6D -SM1 -3
Orange Peel Drywall
Bedroom Closet Wall
SM
SD
—900 ft2
Friable
ND
Texture
HA - Homogeneous Area G - Good CHRY - Chrysotile SM - Surfacing Material
ND - None - detect D - Damaged ACT - Actinolite MM - Miscellaneous Material
TR - Trace, <1% Visual Estimate SD - Significantly Damaged TSI - Thermal System Insulation
8.0 Conclusion & Recommendations
ACM was not identified within the areas of the residences that were within the scope of the limited
inspection and bulk- sampling performed on June 1, 2012; therefore, no professional abatement activities
are required to remove or disturb the above - referenced sampled materials.
9.0 Asbestos Abatement & Demolition Requirements
If ACM is to be removed or disturbed in a single- family residence, and the total quantity exceeds any of
the regulatory trigger levels of 50 linear ft. on pipes, 32 ft2 on other surfaces, or the volume equivalent of
a 55- gallon drum, a CDPHE - certified General Abatement Contractor (GAC) is required to perform the
work. The regulatory trigger levels within a commercial building are 260 linear ft. on pipes, 160 ft2 on
other surfaces, or the volume equivalent of a 55- gallon drum. In addition, formal notification to CDPHE
prior to the abatement of ACM as well as air monitoring, visual inspections, and final air clearances by a
CDPHE - certified Asbestos AMS is required. DSC can provide the client or building owner with a proposal
for project design, abatement oversight and air monitoring upon request.
CDPHE regulations allow for the demolition of a building that contains non - friable asbestos - containing
materials, such as caulking, mastic or resilient floor tiles. However, demolition must be completed
without causing the non - friable ACM to be rendered friable. Burning a building with any ACM is
prohibited. Operations such as sanding, cutting, crushing, grinding, pneumatic jacking, etc. of ACM are
not permitted. Recycling of building materials such as concrete, metal, or wood that are bonded or
contaminated with ACM, e.g. glue, caulking, or mastic is also prohibited. If any of the non - friable asbestos
containing materials are to be recycled and rendered friable after demolition (i.e. crushing mastic - coated
concrete), these materials must be abated of all ACM prior to shipping offsite for recycling.
OSHA regulations regarding occupational exposure during demolition activities is still mandatory. OSHA
29 CFR 1926.1101 requires that workers performing construction - related activities be protected from
asbestos fibers in excess of the permissible exposure limit of 0.1 f /cc of air. Contractors are must comply
with applicable provisions of OSHA 29 CFR 1926.1101 during demolition and renovation activities.
These OSHA provisions include, but are not limited to, PPE and respirators, personnel training, personal -
exposure air monitoring, employee medical surveillance, wet removal methods, signage for regulated
areas, etc.
10.0 Major Asbestos Spill Response
If ACM is significantly damaged and the total quantity exceeds the regulatory trigger levels, the area is
deemed a "Major Asbestos Spill." The area is consequently subject to the requirements in Reg. 8, Section
III.T.1. - Major Asbestos Spills, as outlined below. Additional asbestos air or dust sampling should also be
conducted within the remaining areas not directly impacted by the Major Asbestos Spill to determine if
asbestos - containing dust /debris has spread to adjacent areas. If asbestos fibers are found within any
other areas or on building contents, they should be included in the scope of professional abatement and
decontamination. The following response actions must be followed per Colorado Reg. 8 when a Major
Asbestos Spill occurs:
• Restrict access to the area and post warning signs to prevent entry to the area by persons other
than those necessary to respond to the incident.
• Shut off or temporarily modify the air handling system to prevent the distribution of asbestos
fibers to other areas.
• Immediately contact the Division by telephone, submit a notification in compliance with
subsection III.E. (Notifications) and, if in an area of public access, apply for a permit in accordance
with subsection III.G. (Permits).
• Be exempted from the requirements to have a certified Supervisor on -site at all times, until such
time as the immediate danger has passed. Any cleanup or asbestos abatement that must occur
after the immediate danger has passed shall be supervised by a person certified by the Division.
• Using certified Supervisors and certified Workers in accordance with section II. (Certification
Requirements) of this Regulation, seal all openings between the contaminated and
uncontaminated areas and establish none - detect air pressure within the contaminated area in
accordance with paragraph III.J. (Air Cleaning and None - detect Pressure Requirements). This is to
be accomplished using polyethylene sheeting to cover areas such as doorways, windows, elevator
openings, corridor entrances, grills, drains, grates, diffusers and skylights.
• HEPA vacuum or steam clean all carpets, drapes, upholstery, and other non - clothing fabrics in the
contaminated area, or discard these materials.
• Launder or discard contaminated clothing in accordance with subsection III.R. (Waste Handling).
• HEPA vacuum or wet clean all surfaces in the contaminated area.
• Discard all materials in accordance with subsection III.R. (Waste Handling).
• Following completion of subparagraph III.T.1.a. through III.T.1.i. above, comply with air
monitoring requirements as described in subsection III.P. (Clearing Abatement Projects); air
samples shall be collected aggressively as described in 40 C.F.R. Part 763, Appendix A to Subpart
E (EPA 1995), except that the air stream of the leaf blower shall not be directed at any friable ACM
that remains in the area and
• Comply with any other measures deemed necessary by the Division to protect public health.
11.0 Disclaimer & Limitations
The activities outlined in this report were conducted in a manner consistent with a level of care and
expertise exercised by members of the environmental consulting and industrial hygiene profession. All
activities were performed in accordance with all applicable federal, state, and local regulations as well as
generally accepted standards and professional practice. No warranty is either expressed or implied. DSC
assumes no responsibility or liability for error in public information utilized, statements from sources
other than DSC, or developments resulting from situations outside the scope of this project.
The details provided within this report outline the inspection activities on the date(s) indicated and
should not be relied upon to represent conditions at a later date, the limited number of bulk - samples
collected, and the laboratory results of those bulk - samples. The laboratory results contained in this
report apply specifically to the materials in which bulk - samples were collected. The results do not
include or apply to any other materials within the structure that were not sampled, but may contain
asbestos; including materials that may be hidden or inaccessible. Additional inspection and bulk -
sampling activities would be required to determine if any other materials contain asbestos.
This report has been prepared on behalf of and exclusively for use by the Client, with specific application
to their project as discussed in the scope of work. The results of any surfacing material indicated in this
report also includes any associated overspray of that material, e.g., under carpet, above suspended
ceilings, etc. The information contained in this report is intended as supplementary material for
abatement design and is not to be used as the scope of work for abatement activities, bidding or billing
purposes. Contractors or consultants reviewing this report must draw their own conclusions regarding
further investigation or remediation deemed necessary. DSC can provide a full scope of work for
abatement upon request. DSC does not warrant the work of regulatory agencies, laboratories or other
third parties supplying information which may have been used in the preparation of this report.
E
APPENDIX A
INSPECTOR & FIRM ASBESTOS CERTIFICATES
10
STATE OF COLORADO
ASBESTOS
CERTIFICATION*
('olorado Deparinxnt of Public Ilealth
and Environment
f#' Air Pollution Control Division
This certitics that
Steve Shurtliff
( ertillcation No: I5413
has met the requirements of 25- 7.507, ('.R.S. and Air Quality Control
Commission Regulation No. R. Part B. and is hereby certified by the
state of Colorado in the following discipline:
Building Inspector*
Issued: 6112/2011
F:xpireson: NI2,2012 /
Arco NepT W—
f
' IAI, wN�a ,elN.j.vei Mels ,.n,l.n. /�nrmfOlHaw.yp�,rinW,np ,wne
.m,Il.vn.. i. rA..G., V>�yiMpH1 /Ana
STATE OF COLORADO
ASBESTOS CONSULTING FIRM
II
Colorado Department of Public I Ic tlth
#
and Environment
Air Pollution Control Division
X.
Ibis certifies that
'
, >-
j'
DS Consulting, Inc.>
t
1
S
Registration No. ACF - 14912 }
has met the'reRistration
reygiremeuts of 25 -' -507. C'. R.S. and the Air Qu ty Control
Commission Regulation-'No. X, Part 13, and is hereby authorized to perform ashl consulting
activities as required
urider Regal atidir No R. fart B. in the state or Colorado.
L A
Issued: January 30, 2012
Expires: January 30. 2013
A.Wrile AM[)negesentst-
-1 J .
II
ANALYTICAL DATA
12
AAA��.'
'A'ERObiOAOqy I11bORATORy
ASSOCIATFS, INCORPORATED
revaoess
Certificate of Analysis
13949 W. Colfax Ave
Suite 205
Lakewood, CO 80401
303.232.3746
www.aerobioloay.net
Client Name
Street address
DS Consulting
5366 Flatrock Ct
_ ^�14)-)
w
Date Collected:
Date Received:
06/01/12
06/01/12
City, State ZIP
Morrison, CO 80465
Non - Fibrous
Material
Percentage
Date Analyzed:
06/04/12
Attn:
Steve Shurtliff
NVLAP Lab Code 200860 -0
Date Reported:
06/05/12
Client Project Name:
1376 Westhaven Dr, Vail, CO
TR = Tremolite
Project ID:
12006329
C
12006329 -1B
White Texture w/White Paint
Job ID:
Report #2
Test Requested: 3002, Asbestos in Bulk Samples
Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993.
Sample Identification
Physical Description of Sample/Layer
Homo-
geneous
(Y N)
Layer
Percentage
Asbestos Detected
Asbestos Percentage
Non - Asbestos
Fiber
Percentage
Non - Fibrous
Material
Percentage
Matrix
Material
Composition
Client
Lab Sample Number
6A -SM1 -1
12006329 -1A
White Texture w/White Paint
N
30%
ND
TR = Tremolite
Paul appe
Laboratory Analyst
100
C
12006329 -1B
White Texture w/White Paint
N
30%
ND
100
C
12006329 -1C
Brown Fibrous Material
N
40%
ND
98
2
6A -SM 1 -2
12006329 -2A
White Texture w/White Paint
N
10%
ND
100
C
12006329 -2B
White Joint Compound
N
20%
ND
100
C
12006329 -2C
White /Tan Drywall
N
30%
ND
15
85
G
12006329 -2D
White Tape
N
40%
ND
98
2
6A -SM1 -3
12006329 -3A
Brown Fibrous Material
N
30%
ND
98
2
12006329 -3B
White Texture w/White Paint
N
30%
ND
100
C
12006329 -3C
White Texture w/White Paint
N
40%
ND
100
C
Page 1 of 4
Q = Quartz P = Perlite
C = Carbonates B = Binder
G = Gypsum D= Diatoms
M = Mica
T = Tar
NTR = Non - Asbestiform TR
NAC = Non- Asbestiform AC
A = Amosite
AC = Actinolite
AN = Anthophyllite
CHRY = Chrysotile
CR = Crocidolite
TR = Tremolite
Paul appe
Laboratory Analyst
Paul Knappe
Asbestos Laboratory Supervisor
Trace =Less Than 1%
ND =None Detected
13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746
Page 1 of 4
Q = Quartz P = Perlite
C = Carbonates B = Binder
G = Gypsum D= Diatoms
M = Mica
T = Tar
NTR = Non - Asbestiform TR
NAC = Non- Asbestiform AC
AEROb�O�OC�y LAI�ORATORy
ASSOCIATES, INCORPORATE[
Certificate of Analysis
13949 W. Colfax Ave
Suite 205
Lakewood, CQ 80401
303.232.3746
www.aerobioloay.net
Client Name
Street address
DS Consulting
5366 Flatrock Ct
r,\n �n ^au
I�Ij
Date Collected:
Date Received:
06/01/12
06/01/12
City, State ZIP
Morrison, CO 80465
Non- Fibrous
Material
Percentage
Date Analyzed:
06/04/12
Attn:
Steve Shurtliff
NVLAP Lab Code 200860 -0
Date Reported:
06/05/12
Client Project Name:
1376 Westhaven Dr, Vail, CO
Trace =Less Than I%
Project ID:
12006329
C
12006329 -413
Brown Fibrous Material
Job ID:
Report #2
Test Requested: 3002, Asbestos in Bulk Samples
Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA- 600/R- 93/116, July 1993.
Sample Identification
Physical Description of Sample/Layer
Homo-
geneous
Y/N
Layer
Percentage
Asbestos Detected
Asbestos Percentage
Non- Asbestos
Fiber
Percentaize
Non- Fibrous
Material
Percentage
Matrix
Material
Composition
Client
Lab Sample Number
6C -SM1 -1
12006329 -4A
White Texture wBrown Paint
N
50%
ND
Trace =Less Than I%
Laboratory Analyst
100
C
12006329 -413
Brown Fibrous Material
N
50%
ND
98
2
6C -SM 1 -2
12006329 -5A
White Texture wBlack Paint
N
20%
ND
100
C
12006329 -5B
White Tape
N
20%
ND
98
2
12006329 -5C
White Joint Compound
N
20%
ND
100
C
12006329 -5D
White /Tan Drywall
N
40%
ND
15
85
G
6C -SM 1 -3
12006329 -6A
White Tape
N
10%
ND
98
2
12006329 -613
White Joint Compound
N
20%
ND
100
C
12006329 -6C
White Texture wBlack Paint
N
30%
ND
100
C
12006329 -6D
White /Tan Drywall
N
40%
ND
15
85
G
Page 2 of 4
Q = Quartz P = Perlite
C = Carbonates B = Binder
G = Gypsum D= Diatoms
M = Mica
T = Tar
NTR = Non - Asbestiform TR
NAC = Non - Asbestiform AC
A = Amosite
AC = Actinolite
AN = Anthophyllite
CHRY= Chrysotile
CR = Crocidolite
TR = Tremolite
Paul appe
Paul Knappe
Trace =Less Than I%
Laboratory Analyst
Asbestos Laboratory Supervisor
ND =None Detected
13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746
Page 2 of 4
Q = Quartz P = Perlite
C = Carbonates B = Binder
G = Gypsum D= Diatoms
M = Mica
T = Tar
NTR = Non - Asbestiform TR
NAC = Non - Asbestiform AC
AERObiOtOCiy LAbORATORy
ASSOCC�IATTES, INCORPORATFn
e�
Certificate of Analysis
13949 W. Colfax Ave
Suite 205
Lakewood, CO 80401
303.232.3746
www.aerobioloay.net
Client Name
Street address
DS Consulting
5366 Flatrock Ct
�n
�
Date Collected:
Date Received:
06/01/12
06/01/12
City, State ZIP
Morrison, CO 80465
UU
Date Analyzed:
06/04/12
Attn:
Steve Shurtliff
NVLAP Lab Code 200860 -0
Date Reported:
06/05/12
Client Project Name:
1376 Westhaven Dr, Vail, CO
Trace =Less Than 1%
ND =None Detected
Project ID:
12006329
12006329 -713
White Joint Compound
Job ID:
Report #2
Test Requested: 3002, Asbestos in Bulk Samples
Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA- 6001R- 93/116, July 1993.
Sample Identification
Physical Description of Sample/Layer
Homo-
geneous
Y/N
Layer
Percentage
Asbestos Detected
Asbestos Percentage
Non- Asbestos
Fiber
Percentage
Non - Fibrous
Material
Percentage
Matrix
Material
Composition
Client
Lab Sample Number
6D -SM 1- I
12006329 -7A
White Tape
N
10%
ND
Trace =Less Than 1%
ND =None Detected
99
1
12006329 -713
White Joint Compound
N
20%
ND
3
97
C
12006329 -7C
White Texture w/White Paint
N
30%
ND
3
97
C
12006329 -71)
Tan/White Drywall
N
40%
ND
10
90
G
6D -SM 1 -2
12006329 -8A
White /Tan Drywall
N
3%
ND
10
90
G
12006329 -8B
White Joint Compound
N
7%
ND
3
97
C
12006329 -8C
White Tape
N
20%
ND
99
1
12006329 -813
White Texture w/White Paint
N
70%
ND
3
97
C
6D -SM 1 -3
12006329 -9A
White Texture w/White Paint
N
40%
ND
3
97
C
12006329 -913
Tan/White Drywall
N
60%
ND
10
90
G
Page 3 of 4
Q = Quartz P = Perlite
C = Carbonates B = Binder
G = Gypsum D= Diatoms
M = Mica
T = Tar
NTR = Non- Asbestiform TR
NAC = Non - Asbestiform AC
A = Amosite
AC = Actinolite
//•
%x'— �//
�� •- O�j� -'
AN Anthophyllite
CHRY= Chrysotile
CR = Crocidolite
TR = Tremolite
Paul appe
Laboratory Analyst
Paul Knappe
Asbestos Laboratory Supervisor
Trace =Less Than 1%
ND =None Detected
13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746
Page 3 of 4
Q = Quartz P = Perlite
C = Carbonates B = Binder
G = Gypsum D= Diatoms
M = Mica
T = Tar
NTR = Non- Asbestiform TR
NAC = Non - Asbestiform AC
General Notes
♦ ND indicates no asbestos was detected; the method detection limit is 1 %.
♦ Trace or " <1" indicates asbestos was identified in the sample, but the concentration is less than 1 %.
♦ All regulated asbestos minerals (i.e. chrysotile, amosite, crocidolite, anthophyllite, tremolite, and actinolite) were sought in every layer of each sample, but only those asbestos
minerals detected are listed. Amosite is the common name for the asbestiform variety of the minerals cummingtonite and grunerite. Crocidolite is the common name used for the
asbestiform variety of the mineral riebeckite.
♦ Tile, vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter (< 0.25 microns in diameter) that these fibers cannot be detected by PLM.
For such samples, more sensitive analytical methods (e.g. TEM, SEM, and XRD) are recommended if greater certainty about asbestos content is required. Semi - quantitative bulk TEM
floor tile analysis is accepted under NESHAP regulations.
♦ These results are submitted pursuant to Aerobiology Laboratory Associates, Inc.'s current terms and conditions of sale, including the company's standard warranty and limitation
of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted.
♦ Unless notified in writing to return the samples covered by this report, Aerobiology Laboratory Associates, Inc. will store the samples for a minimum period of thirty (30) days
before discarding. A shipping and handling charge will be assessed for the return of any samples.
♦ Aerobiology does not guarantee the results of tape lifts, microvacs, wipe, and/or debris samples. Accurate analysis cannot be performed due to particle size, media used, and/or
amount of material given. Analysis of these materials should be preformed by a TEM. A result of ND does not indicate that the sample area does not contain asbestos. It means the
analyst could not identify asbestos in the specific sample for the reasons listed above.
Notes Required by NVLAP
♦ This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
♦ This test report relates only to the items tested or calibrated.
♦ This report is not valid unless it bears the name of a NVLAP- approved signatory.
♦ Any reproduction of this document must include the entire document in order for the report to be valid.
Page 4 of 4 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746
13949 W. Colfax Ave
Suite 205
AEROI7icAc>gy LABORATORY
Lakewood, CO 80401
ASSOCIATES, INCORPORATED
303.232.3746
G�„► ,
Certificate of Analysis
www.aerobioloay.net
DS Consulting
5366 Flatrock Ct
n � p,
Ll\J
Date Collected:
Date Received:
06/01/12
06/01/12
Morrison, CO 80465
Date Analyzed:
06/04/12
Steve Shurtliff
NVLAP Lab Code 200860 -0
Date Reported:
06/05/12
Client Project Name: 1376 Westhaven Dr, Vail, CO
Project ID:
12006329
Job ID:
Report #2
General Notes
♦ ND indicates no asbestos was detected; the method detection limit is 1 %.
♦ Trace or " <1" indicates asbestos was identified in the sample, but the concentration is less than 1 %.
♦ All regulated asbestos minerals (i.e. chrysotile, amosite, crocidolite, anthophyllite, tremolite, and actinolite) were sought in every layer of each sample, but only those asbestos
minerals detected are listed. Amosite is the common name for the asbestiform variety of the minerals cummingtonite and grunerite. Crocidolite is the common name used for the
asbestiform variety of the mineral riebeckite.
♦ Tile, vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter (< 0.25 microns in diameter) that these fibers cannot be detected by PLM.
For such samples, more sensitive analytical methods (e.g. TEM, SEM, and XRD) are recommended if greater certainty about asbestos content is required. Semi - quantitative bulk TEM
floor tile analysis is accepted under NESHAP regulations.
♦ These results are submitted pursuant to Aerobiology Laboratory Associates, Inc.'s current terms and conditions of sale, including the company's standard warranty and limitation
of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted.
♦ Unless notified in writing to return the samples covered by this report, Aerobiology Laboratory Associates, Inc. will store the samples for a minimum period of thirty (30) days
before discarding. A shipping and handling charge will be assessed for the return of any samples.
♦ Aerobiology does not guarantee the results of tape lifts, microvacs, wipe, and/or debris samples. Accurate analysis cannot be performed due to particle size, media used, and/or
amount of material given. Analysis of these materials should be preformed by a TEM. A result of ND does not indicate that the sample area does not contain asbestos. It means the
analyst could not identify asbestos in the specific sample for the reasons listed above.
Notes Required by NVLAP
♦ This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
♦ This test report relates only to the items tested or calibrated.
♦ This report is not valid unless it bears the name of a NVLAP- approved signatory.
♦ Any reproduction of this document must include the entire document in order for the report to be valid.
Page 4 of 4 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746