Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
F12-0024 Stamped plans
RECEI V V ED 05/24/2012 @ 10:43am PRJ12-0010 B12-0045 F12-0024 FIRE PROTECTION SUBMITTAL MONTGOMERY RESIDENCE 385 E. GORE CREEK DR. UNIT 101 & 102 VAIL, CO 81658 Prepared by: Jason Brochu Project Manager Western States Fire Protection 7026 S. Tucson Way Centennial, CO 80112 Phone: (303) 792 ‐0022 Fax: (303) 792 ‐9049 Cell: (303) 928 ‐0192 Email: jason.brochu@wsfp.us WSFP #CS1506 May 23, 2012 Hydraulic Summary Report Description: Kitchen Job Number: CS1506 Node Flow(gpm)Total Hose Streams 100.00 Safety Margin Required Available Node Hose FlowStaticResidualFlowTotal Demand (gpm)(psi)(psi)(gpm)(psi)(gpm)(psi)(psi)@ @ 1 84.80973.53111.278 722.75 100.0081.740 85.150208.03 Design Engineer Job Number Total Water Required (Including Hose Allowance)208.03 Maximum Pressure Unbalance In Loops 0.000 Additional Hose Supplies 100.00 Hose Allowance At Source Supplies 81.22gal Residential 0.100gpm/ft²100.00ft²900.00ft² (Actual 290.44ft²)4 Occupancy Area of Application Coverage Per Sprinkler Number Of Sprinklers Calculated Density Job Suffix AutoPeak Results: Pressure For Remote Area(s) Adjacent To Most Remote Area Volume capacity of Dry Pipes Volume capacity of Wet Pipes 2.97 between nodes 1 and 3 Maximum Velocity Under Ground 18.38 between nodes 20 and 21 Maximum Velocity Above Ground 5.6 K-Factor 26.00 at 21.556 Most Demanding Sprinkler Data System Unit 301 and 302 Job Site/Building 385 Gore Creek Dr.AHJ Montgomery Residence Remodel Job State Certification/License Number Job Name:Jason Brochu CS1506 Contractor Contractor Number 21 Name of Contractor:Western States Fire Protection Address 1 7026 South Tucson Way Address 2 Centennial, CO 80112 Contact NameContact Title Project Manager Extension Phone (303) 792 - 0022 FAX (303) 792 - 9049 E-mail jason.brochu@wsfp.us Web-Site www.wsfp.com Jason Brochu Address 3 Address 1 Address 2 Drawing Name Montgomery Residence Grid.cad System Flow Demand 108.03 Remote Area(s)Address 3 Vail, CO 81658 05/16/2012 © M.E.P.CAD, Inc.Page 1 AutoSPRINK® VR8 v8.1.12.010:21:59AM Device (gpm)Actual FlowMinimum Flow (gpm)(K)K-Factor (psi)Pressure Summary Of Outflowing Devices Report Description: Kitchen Job Number: CS1506 Sprinkler10126.0026.005.621.556 Sprinkler10226.6226.005.622.593 Sprinkler10327.0026.005.623.239 Sprinkler10428.4126.005.625.741 Most Demanding Sprinkler Data © M.E.P.CAD, Inc.05/16/2012Page 1 AutoSPRINK® VR8 v8.1.12.010:22:08AM Fittings NodeElevation(Foot)Pressure(psi)Discharge(gpm)Node Analysis Report Description: Kitchen Job Number: CS1506 1-13'-11S73.531108.03 10116'-4Spr(-21.556)21.55626.00 10216'-6Spr(-22.593)22.59326.62 10316'-6Spr(-23.239)23.23927.00 10416'-6Spr(-25.741)25.74128.41 3-12'-3½E(7'-0)72.694 168'-4T(3'-6)32.151 178'-4cplg(1'-0)31.520 2016'-10T(2'-0)25.971 2116'-10T(2'-0)23.435 2216'-10T(2'-0)22.780 2616'-10T(3'-6)27.046 2716'-10T(2'-0)22.790 3416'-1T(3'-6)28.240 3916'-1T(2'-0)27.899 626'-4E(3'-6)43.753 738'-4T(5'-0)35.032 7414'-1T(3'-6)31.178 7714'-1T(2'-0)31.889 7814'-1T(2'-0)32.126 8014'-1T(3'-6)31.210 11414'-1T(3'-6)31.248 12013'-8T(2'-0)31.425 © M.E.P.CAD, Inc.05/16/2012Page 1 AutoSPRINK® VR8 v8.1.12.010:22:27AM Pipe TypeDiameterFlowVelocityFriction LossLengthPressure DownstreamElevationDischargeK-FactorPtPnFittingsEq. LengthSummary Upstream Total Length HWC Hydraulic Analysis Job Number: CS1506 Report Description: Kitchen • • • • • Route 1 • • • • •Pf Pe Pv BL1.055026.009.540.1360916'-81.451 10116'-426.005.621.556Sprinkler,4'-0-0.217 2716'-1022.7902E(2'-0)10'-8 150 Pf Pe Pv BL1.055029.5410.840.17229923'-9¼4.784 2716'-103.5422.790Flow (q) from Route 64'-00.325 3916'-127.899E(2'-0), T(2'-0)27'-9¼150 Pf Pe Pv BL1.527029.545.170.0284598'-5½0.341 3916'-127.8993'-6 3416'-128.240T(3'-6)11'-11½150 Pf Pe Pv FM1.527061.4510.770.11037412'-9¼2.071 3416'-131.9228.240Flow (q) from Route 56'-00.867 7414'-131.178E(2'-6), T(3'-6)18'-9¼150 Pf Pe Pv FM1.527059.1610.360.1028670'-3¾0.032 7414'-131.178 8014'-131.2100'-3¾150 Pf Pe Pv FM1.527053.339.340.0849018'-00.679 8014'-131.210 7714'-131.8898'-0 150 Pf Pe Pv FM1.527061.4510.770.1103742'-1¾0.236 7714'-18.1331.889Flow (q) from Route 7 7814'-132.1262'-1¾150 Pf Pe Pv BL2.009061.456.220.0290175'-90.413 7814'-132.1268'-62.493 738'-435.032E(3'-6), T(5'-0)14'-3 150 Pf Pe Pv FM2.0090108.0310.930.08239176'-3¾7.853 738'-446.5735.032Flow (q) from Route 219'-00.868 626'-443.7534E(3'-6), T(5'-0), CV95'-3¾150 Pf Pe Pv FM3.9350108.032.850.00311939'-220.868 626'-443.75316'-08.073 3-12'-3½72.694 2E(7'-0), Tr(2'-0), BFP(-12.446), PRV(-8.250)55'-2 150 Pf Pe Pv UG3.8570108.032.970.00343831'-7½0.133 3-12'-3½72.694Supply,7'-00.704 1-13'-1173.531E(7'-0), S38'-7½150 208.03 100.00Hose Allowance At Source 1 • • • • • Route 2 • • • • •Pf Pe Pv BL1.055026.629.770.1421330'-40.332 10216'-626.625.622.593Sprinkler,2'-0-0.145 2216'-1022.780T(2'-0)2'-4 150 Pf Pe Pv BL1.055023.088.470.1091886'-00.655 2216'-1022.780 2116'-1023.4356'-0 150 Pf Pe Pv BL1.055050.0818.380.4575815'-6½2.536 2116'-1027.0023.435Flow (q) from Route 3 2016'-1025.9715'-6½150 Pf Pe Pv BL1.527078.4913.750.1735692'-8¼1.076 2016'-1028.4125.971Flow (q) from Route 43'-6 2616'-1027.046T(3'-6)6'-2¼150 Pf Pe Pv FM1.527046.578.160.0660898'-60.792 2616'-1027.0463'-63.681 178'-431.520E(2'-6), cplg(1'-0)12'-0 150 Pf Pe Pv FR1.527046.578.160.0660895'-11¾0.627 178'-431.5203'-60.004 168'-432.151T(3'-6)9'-5¾150 Pf Pe Pv BL1.527046.578.160.06608934'-1¼2.881 168'-432.1519'-6 738'-435.0322T(3'-6), E(2'-6)43'-7¼150 • • • • • Route 3 • • • • •Pf Pe Pv BL1.055027.009.910.1458910'-40.340 10316'-627.005.623.239Sprinkler,2'-0-0.145 2116'-1023.435T(2'-0)2'-4 150 • • • • • Route 4 • • • • •Pf Pe Pv BL1.055028.4110.430.1603630'-40.374 10416'-628.415.625.741Sprinkler,2'-0-0.145 2016'-1025.971T(2'-0)2'-4 150 • • • • • Route 5 • • • • •Pf Pe Pv BL1.527031.925.590.03284716'-11¼0.869 2616'-1027.046T(3'-6)9'-60.325 3416'-128.240T(3'-6), E(2'-6)26'-5¼150 • • • • • Route 6 • • • • •© M.E.P.CAD, Inc.05/16/2012Page 1 AutoSPRINK® VR8 v8.1.12.010:22:36AM Pipe TypeDiameterFlowVelocityFriction LossLengthPressure DownstreamElevationDischargeK-FactorPtPnFittingsEq. LengthSummary Upstream Total Length HWC Hydraulic Analysis Job Number: CS1506 Report Description: Kitchen Pf Pe Pv BL1.05503.541.300.0033951'-0½0.010 2216'-1022.7802'-0 2716'-1022.790T(2'-0)3'-0½150 • • • • • Route 7 • • • • •Pf Pe Pv BL1.52702.300.400.0002529'-10½0.004 12013'-831.4256'-0-0.181 11414'-131.248E(2'-6), T(3'-6)15'-10½150 Pf Pe Pv BL1.05508.132.980.01582634'-6¼0.641 11414'-15.8331.248Flow (q) from Route 86'-0 7714'-131.8892T(2'-0), E(2'-0)40'-6¼150 • • • • • Route 8 • • • • •Pf Pe Pv FM1.48105.831.090.00164219'-7¼0.038 8014'-131.210T(3'-6)3'-6 11414'-131.24823'-1¼150 • • • • • Route 9 • • • • •Pf Pe Pv FM1.05502.300.840.00152731'-30.066 7414'-131.17812'-00.181 12013'-831.4252E(2'-0), 4T(2'-0)43'-3 150 1.51 4.87 150 1.33 140 1.16 130 0.713 100 Equivalent Pipe Lengths of Va lves and Fittings (C=120 only)Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc.05/16/2012Page 2 AutoSPRINK® VR8 v8.1.12.010:22:36AM Pipe TypeDiameterFlowVelocityFriction LossLengthPressure DownstreamElevationDischargeK-FactorPtPnFittingsEq. LengthSummary Upstream Total Length HWC Hydraulic Analysis Job Number: CS1506 Report Description: Kitchen Pipe Type Legend AOArm-Over BLBranch Line CMCross Main DNDrain DRDrop DYDynamic FMFeed Main FRFeed Riser MSMiscellaneous OROutrigger RNRiser Nipple SPSprig STStand Pipe UGUnderground Units Legend DiameterInch ElevationFoot Flowgpm Dischargegpm Velocityfps Pressurepsi LengthFoot Friction Losspsi/Foot HWCHazen-Williams Constant PtTotal pressure at a point in a pipe PnNormal pressure at a point in a pipe PfPressure loss due to friction between points PePressure due to elevation difference between indicated points PvVelocity pressure at a point in a pipe Fittings Legend ALVAlarm Valve AngVAngle Valve bBushing BalVBall Valve BFPBackflow Preventer BVButterfly Valve CCross Flow Turn 90°cplgCoupling CrCross Run CVCheck Valve DelVDeluge Valve DPVDry Pipe Valve E90° Elbow EE45° Elbow Ee111¼° Elbow Ee222½° Elbow fFlow Device fdFlex Drop FDCFire Department Connection fE90° FireLock(TM) Elbow fEE45° FireLock(TM) Elbow flgFlange FNFloating Node fTFireLock(TM) Tee gGauge GloVGlobe Valve GVGate Valve HoHose HoseHose HVHose Valve HydHydrant LtELong Turn Elbow mecTMechanical Tee NozNozzle P1Pump In P2Pump Out PIVPost Indicating Valve POPipe Outlet PRVPressure Reducing Valve PrVPressure Relief Valve redReducer/Adapter SSupply sCVSwing Check Valve SprSprinkler StStrainer TTee Flow Turn 90°TrTee Run UUnion WirFWirsbo WMVWater Meter Valve ZCap © M.E.P.CAD, Inc.05/16/2012Page 3 AutoSPRINK® VR8 v8.1.12.010:22:36AM Hydraulic Graph Report Description: Kitchen Job Number: CS1506 System Demand (Including Hose Allowance at Source)System Demand 81.740 @ 722.75 Residual: Pressure 85.150 Static: Pressure Supply at Node 1 Hydraulic Graph Supply at Node 1 73.531 @ 108.03 73.531 @ 208.03 Available Pressure at Time of Test 84.809 @ 208.03 © M.E.P.CAD, Inc.05/16/2012Page 1 AutoSPRINK® VR8 v8.1.12.0 10:23:02AM Flow Diagram (Top View)Report Description: Kitchen Job Number: CS1506 © M.E.P.CAD, Inc.05/16/2012Page 1 AutoSPRINK® VR8 v8.1.12.010:23:11AM Hydraulic Summary Report Description: Kitchen Job Number: CS1506 Node Flow(gpm)Total Hose Streams 100.00 Safety Margin Required Available Node Hose FlowStaticResidualFlowTotal Demand (gpm)(psi)(psi)(gpm)(psi)(gpm)(psi)(psi)@ @ 1 84.80973.53111.278 722.75 100.0081.740 85.150208.03 Design Engineer Job Number Total Water Required (Including Hose Allowance)208.03 Maximum Pressure Unbalance In Loops 0.000 Additional Hose Supplies 100.00 Hose Allowance At Source Supplies 81.22gal Residential 0.100gpm/ft²100.00ft²900.00ft² (Actual 290.44ft²)4 Occupancy Area of Application Coverage Per Sprinkler Number Of Sprinklers Calculated Density Job Suffix AutoPeak Results: Pressure For Remote Area(s) Adjacent To Most Remote Area Volume capacity of Dry Pipes Volume capacity of Wet Pipes 2.97 between nodes 1 and 3 Maximum Velocity Under Ground 18.38 between nodes 20 and 21 Maximum Velocity Above Ground 5.6 K-Factor 26.00 at 21.556 Most Demanding Sprinkler Data System Unit 301 and 302 Job Site/Building 385 Gore Creek Dr.AHJ Montgomery Residence Remodel Job State Certification/License Number Job Name:Jason Brochu CS1506 Contractor Contractor Number 21 Name of Contractor:Western States Fire Protection Address 1 7026 South Tucson Way Address 2 Centennial, CO 80112 Contact NameContact Title Project Manager Extension Phone (303) 792 - 0022 FAX (303) 792 - 9049 E-mail jason.brochu@wsfp.us Web-Site www.wsfp.com Jason Brochu Address 3 Address 1 Address 2 Drawing Name Montgomery Residence Grid.cad System Flow Demand 108.03 Remote Area(s)Address 3 Vail, CO 81658 05/16/2012 © M.E.P.CAD, Inc.Page 1 AutoSPRINK® VR8 v8.1.12.010:21:06AM ModelRFC56Concealed ResidentialSprinkler (SINRA0914)ProductDescription ModelRFC56ConcealedResidentialSprinklersarefast responseresidentialfusiblesold erlinkautomaticsprinklers.Residentialsprinklersdifferfro mstandardsprinklersprimarily intheirresponsetimeandwaterdistributionpatterns.ModelRFC56sprinklersdischargewaterina hemisphericalpatternbelowthesprinklerdeflector.Residentialdistributionpatternsarehigherandgenerally containafinerdropletsizethanstandardsprinklerpatterns.Thecombinationofspeedofoperationandhighdischarge patternrequiredforresidentialsprinklershasdemonstrated,infiretesting,anabilityforcontrollingresidentialfires,and therebyprovidingsignifi cantevacuationtimeforoccupants.TheRFC56Sprinklerprovidesthebestformoffire protectionbycombininganattractiveappearanceand½(13mm)ofcoveradjustmentforeaseofinstallation.The smalldiametercoverplateiseasilyandpositivelyattached andblendsintotheceiling,concealingthemostdependable fireprotectionavailable,anautomaticsprinklersystem.TheRFC56isaULListedResidentialSprinklertobe installedintheresidentialportionsofanyoccupancyin accordancewithNFPA13,13R,&13D.TheRFC56canreducetheneedforprecisecuttingofdrop nipples.Thethreadedcoverplateassemblycanbeadjusted withouttoolstofitaccuratelyagainsttheceiling.Thefire protectionsystemneednotbeshutdowntoadjustorremove thecoverplateassembly.ApplicationandInstallation TheRFC56,forresidentialinstallations,usesa165 F(74 C)fusiblesolderlinkwithadrop-downdeflector.Thisassembly isrecessedintotheceilingandconcealedbyaflatcover plate.Thecoverplateisattachedtotheskirt,using135 F (57 C)ordinarytemperatureclassificationsolder.Whenthe ceilingtemperaturerises,thesolderholdingthecoverplate releasesthecoverallowingthedeflectortodropintoposition andexposingthesprinklerinsidetoceilingtemperature.The TheReliableAutomaticSprinklerCo.,Inc.,103FairviewParkDrive,Elmsford,NewYork10523 Bulletin009 Rev.A B u l l e t i n 0 0 9 R e v .A Listings&Approval 1.ListedbyUnderwritersLaboratories,andcertifiedbyULforCanada(cULus)2.NYCMEA258-93-E ULListingCategories ResidentialAutomaticSprinklers ULGuideNumber VKKW Features 1.½(13mm)Totaladjustment.2.Smoothaestheticceilingprofile.3.Availableinbrass,chromeand blackplatedorpaintedfinishes.AConcealedResidentialSprinkler approvedforaminimumdensityof 0.05gpm/ft 2 .ThelargerKFactor provideslowerpressuredemands for0.10densitiesinNFPA-13 residentialapplications. subsequentoperationofthesolderlinkopensthewaterway todistributethedischargingwaterinahemisphericalpattern belowthesprinklerdeflector.Anyadjustmentofthread engagementbetweenthecoverplateandcupwillassure thatthedrop-downdeflectorisproperlylocatedbelowthe ceiling.Theresidentialdistributionpatterncontainsafiner dropletsizethanastandardsprinkler,andthepattern producessignificantlyhigherwallwetting.Aftera2 5 8 inchdiameterholeiscutintheceiling,the sprinkleriseasilyinstalledwiththeModelG4Wrench.The wrenchhasdrivetangswhichinsertintothecupslots.When installingasprinklerthewrenchisfirstpositionedintothe sprinkler/cupassemblyuntilthewrenchtangsengagethe driveslotsinthetopofthecup(therearetwosetsofdrive slotsinthecup).Thesprinkleristhentightenedintothepipe fitting.Wheninsertingorremovingthewrenchfromthe sprinkler/cupassembly,careshouldbetakentoprevent damagetothesprinkler.DONOTWRENCHONANY OTHERPARTOFTHESPRINKLER/CUPASSEMBLY.MODELRFC56CONCEALEDSPRINKLERSMUSTBE INSTALLEDONLYWITH135°FRATEDCOVERS.Inceilingsthathaveaplenumspaceabovethesprinkler,theplenumspacemayhaveneutralornegative pressurizationbutmustnotbe positivelypressurized.In addition,inspectallsprinklersafterinstallationtoensurethat boththegapbetweenthecoverplate,ceilingandthe4slots inthecupareopenandfreefromanyairflowimpediment.SprinklerCoverPlate Max.Ambient Temp.165 o F/74 o C135 o F/57 o C100 o F/38 o C TemperatureRating ThreadSize inch(mm)K Factor Sprinkler Spacing ft.(m)Maximum Distance toWallft.(m)Minimum Distancebetween sprinklerft.(m)MinimumRequired SprinklerDischarge Flow gpm(Lpm)Press.psi(bar)½(15mm)½(15mm)½(15mm)5.6 5.6 5.6 12x12(3.6x3.6)14x14(4.3x4.3)16x16(4.9x4.9)6(1.83)7(2.13)8(2.43)8(2.43)8(2.43)8(2.43)26(98)26(98)26(98)21.6(1.49)21.6(1.49)21.6(1.49)InstallationData Note:1bar=100Kpa 2. Maintenance ModelRFC56ConcealedSprinklersshouldbeinspected quarterlyandthesprinklersystemmaintainedinaccordance withNFPA25.Donotcleansprinklerswithsoapandwater,ammoniaoranyothercleaningfl uids.Removedustbyusing asoftbrushorgentlevacuuming.Removeanysprinkler coverplateassemblywhichhasbeenpainted(otherthan factoryapplied)ordamagedinanyway.Astockofspare sprinklersshouldbemaintai nedtoallowquickreplacementof damagedoroperatedsprinkl ers.Priortoinstallation,sprinklersshouldbemaintai nedintheoriginalcartonsand packaginguntilusedtominimizethepotentialfordamageto sprinklersthatwouldcauseimproperoperationor non-operation.OrderingInformation Specify:1.SprinklerModel 2.CoverPlateFinish StandardFinishes Chrome White SpecialApplication Finishes BrightBrass BlackPlating BlackPaint OffWhite SatinChrome CoverPlateFinishes (1)(1)Othercolorsandfinishes available.Consultfactory fordetails.Note:Paintoranyother coatingsappliedoverthe factoryfinishwillvoidall approvalsandwarranties.3.ModelRFC56ResidentialConcealed SprinklerSpecification SprinklersshallbecULusListedlowflowresidential concealedsprinklerswithdrop-downdeflectorand adjustableflatcoverplateengineeredforaminimumdesign densityof0.10gpm/ft 2 .Sprinklerframeanddeflectorshallbe ofbronzeconstructionhavinga½”NPTthread.Thermal elementshallconsistofa napprovedblack-painted beryllium-nickelfusiblesolderlinkwithleverandstrut mechanism,maintainingaTef lon-coatedbrasscapwater sealcontainingnoplasticparts .SprinklerK-factorshallbe nominal5.6(80),havinga 1 2 ”orifice.Temperatureratingshall beOrdinary165 F(74 C);coverplatetemperatureratingto be135 F(57 C).Coverplateassemblyshallconsistofa brasscoverplateandcopperalloyretainerflangehavinga push-onandthread-offdesign,allowinga½”coverplate adjustment.Anysecureengagementbetweenthecover plateandthecupwillassurethatthedrop-downdeflectoris properlylocatedbelowtheceiling.Aplasticprotectivecap shallbeprovidedandfactoryins talledinsidethesprinklercup toprotectthedrop-downsprinklerdeflectorfromdamage,whichcouldoccurduringconstruct ionbeforethecoverplate isinstalled.Standardcoverfinish:[Chrome][White][Specialty–specify].Resid entialconcealedsprinklersshall beReliableModelRFC56,SINRA0914(Bulletin009). Manufacturedby:Revisionlinesindicateupdatedornewdata E.G.PrintedinUSA.4/05P/N9999970277 Recycled Paper TheequipmentpresentedinthisbulletinistobeinstalledinaccordancewiththelatestpertinentStandardsoftheNationalFireProtectionAssocia tion,FactoryMutual ResearchCorporation,orothersimilarorganizationsandalsowiththeprovisionsofgovernmentalcodesorordinances,wheneverapplicable.Productsmanufacturedanddistributedb yRELIABLEhavebeenprotectinglifeandpropertyforo ver80years,andareinstalledandservicedbythemost highlyqualified andreputablesprinklercontractorslocatedthroughout theUnitedStates,Canad aandforeigncountries.TheReliableAutomaticSprinklerCo.,Inc.(800)431-1588SalesOffices (800)848-6051SalesFax (914)829-2042CorporateOffices www.reliablesprinkler.com InternetAddress Reliable...ForCompleteProtection Reliableoffersawideselectionofsprinklercomponents.Followingaresomeofthemany precision-madeReliableproductsthatguardlifeandpropertyfromfirearoundtheclock.•Automaticsprinklers •Flushautomaticsprinklers •Recessedautomaticsprinklers •Concealedautomaticsprinklers •Adjustableautomaticsprinklers •Dryautomaticsprinklers •Intermediatelevelsprinklers •Opensprinklers •Spraynozzles •Alarmvalves •Retardingchambers •Drypipevalves •Acceleratorsfordrypipevalves •Mechanicalsprinkleralarms •Electricalsprinkleralarmswitches •Waterflowdetectors •Delugevalves •Detectorcheckvalves •Checkvalves •Electricalsystem •Sprinkleremergencycabinets •Sprinklerwrenches •Sprinklerescutcheonsandguards •Inspectorstestconnections •Sightdrains •Balldripsanddrumdrips •Controlvalveseals •Airmaintenancedevices •Aircompressors •Pressuregauges •Identificationsigns •Firedepartmentconnection BERMAD Fire Protection 700 Series 700E Deluge Valve Data Description BERMAD 700E Deluge Valves are globe valves with integral unitized double chamber actuator that consists of one single moving assembly, which includes a diaphragm assembly, a flat seal disk and a stainless steel removable seat. These automatic water control valves are designed for high pressure service, in vertical or horizontal installations and are available in diameter sizes from 1½” to 16”; DN40 to DN400.The BERMAD 700E valves are used for water flow control in Deluge, Pressure Control Deluge, Preaction or Water/Foam systems, and are manufactured from materials suitable for freshwater or alternative for seawater, foam concentrate or other corrosive fluids.The 700E Deluge Valve is held closed by system water pressure trapped in the control chamber. When the releasing system operates, pressure is released from the control chamber, and the seal disc opens to allow water to flow into the system.The 700E valve body design includes a single, full bore seat with unobstructed flow path, free of any in-line ribs, supporting cage, or stem guides.The 700E “Y Type” design provides high flow capabilities with minimum head loss.The integral unitized double-chambered actuator provides a combination of positive, immediate response with smooth hammer-free, drip-tight closing. The whole actuator can be easily removed for a quick in-line inspection and servicing. Valve actuation is accomplished by one moving assembly which includes a replaceable flat diaphragm, harnessed to the diaphragm assembly, a stainless steel stem and a flat seal disk assembly. The balanced seal-disk assembly with its resilient seal enables controlled actuation, high durability and perfect drip-tight sealing, even under harsh conditions.Accessories The BERMAD 700E Deluge Valve shall be trimmed with the original components and accessories per specification and in accordance with valve functions and applications.Where additional specifications and/or signaling devices are required for a specific application, refer to system data for the system used, and to the BERMAD data sheet and Installation, Operation & Maintenance for specific model required.Main Features ■ High Pressure Construction – 400 psi (28 bar) rating available ■ Integral unitized double chamber actuator with single moving assembly ■ In-line serviceable, field replaceable internals ■ Obstacle free, full bore ■ Available in corrosion resistant materials ■ Designed to be reset without opening the valve ■ Compatible with electric/hydraulic/pneumatic release and pressure control trim systems Approvals ■ UL Listed to UL 260 from 5 to 300 psi; 0.3 to 21 bar WP, 2” through 10”; DN50 through DN250 ■ ABS Approved for 300 psi; 21 bar WP, 1½” through 12”; DN40 through DN300 ■ Lloyd’s Register Type Approval for 300 psi; 21 bar WP, 1½” through 16”; DN40 through DN400 ■ Fire Test Certified to ISO 6182 part 5, 1½” through 16”; DN40 through DN400 Notes: 1. The 700E valve shall be trimmed with specific components & accessories.2. The 700E valve must be installed and maintained in compliance with the most recent BERMAD publications.1 BERMAD Fire Protection 700 Series 700E Materials Specifications Construction Materials The BERMAD 700E valves are available in a variety of materials to ensure optimal suitability for a wide range of applications. For operation involving exposure to internal and/or external corrosive conditions, valves are constructed from corrosion-resistant materials making them suitable for use with seawater, brackish water, or corrosive environments such as seashore, petrochemical and other industrial facilities.Standard Configurations Item Number Description Firewater Valve 1 Cover Ductile Iron 2 Cover Bolt Z.C. Plated Steel 3 Cover Nut Z.C. Plated Steel 4 Separation Partition Ductile Iron 5 Stud Z.C. Plated Steel 6 Stud Nut Z.C. Plated Steel 7 Valve Body Ductile Iron 8 Spring S.S. 302 9 Removable Seat S.S. 304 10 Seal NBR (Buna-N)11 Upper Plug (6-20”)Brass 12 Shaft Lock Nut S.S. 303 13 Shaft Nut S.S. 303 14 Diaphragm Washers S.S. 431 15 Diaphragm NBR (Buna-N)16 Bearing Screw S.S. 303 17 Bearing Bronze 18 Shaft S.S. 303 19 Seal Disk S.S. 431 Specifications Castings ■ Ductile Iron to ASTM A536 65-45-12 (coated)■ Cast Steel ASTM A216 Grade WCB (coated)■ Nickel Aluminum Bronze ASTM B148 C95800 ■ Stainless Steel 316 ASTM A351 Grade CF8M ■ Super Duplex ASTM A890 Grade 5A ■ Hastelloy C-276 Bolting:■ Standard External Bolting: Zinc Plated Steel ■ Optional: S.S.316 to ASTM A320 Gr.B8F Internal Wetted Parts:■ Stainless Steel 303 ASTM A582 95B S30300A ■ Stainless Steel 304 ASTM A743 Grade CF8 ■ Stainless Steel 431 ASTM A743 Grade CA15M ■ Bronze ASTM B505 Grade C83600 ■ Internal Spring - S.S. 302 Optional Internal Wetted Parts:■ Stainless Steel 316 ASTM A351 Grade CF8M ■ Nickel Aluminum Bronze ASTM B148 C95800 ■ Monel 400 ■ Hastelloy C-276 ■ Internal Spring - Inconel Elastomers (Diaphragm & Seals) ■ NBR, Polyamide fabric reinforced Nitrile (Buna-N),Temperature Rating 80°C ■ EPDM, Polyamide fabric reinforced Ethylene-Propylene, Temperature Rating 90°C Coating ■ Electrostatic Powder Coating Polyester ■ High Built Epoxy Fusion-Bonded with UV Protection, Anti-Corrosion ■ Color: Fire Red to RAL 3002 Note: Internal & External coating applied on Ductile Iron or Cast Steel Castings only.Material End Connection Standard Inlet & Outlet Class & Type Max. working pressure psi bar Ductile Iron Flanged ANSI B16.42 #150RF 250 17.4 Flanged ANSI B16.42 #300RF 400 28 Flanged ISO 7005-2 PN 16 235 16 Flanged ISO 7005-2 PN 25 365 25 Grooved ANSI C606 300 400 25 Threaded BSP/NPT 300/PN25 400 25 Cast Steel & Stainless Steel Flanged ANSI B16.5 #150RF 250 17.4 Flanged ANSI B16.5 #300RF 400 28 Flanged ISO 7005-2 PN16 235 16 Flanged ISO 7005-2 PN25 365 25 Threaded BSP/NPT 300/PN25 400 25 Ni-Al Bronze Flanged ANSI B16.24 #150RF 250 17.4 Flanged ANSI B16.24 #300RF 400 28 Flanged ISO 7005-2 PN 16 235 16 Flanged ISO 7005-2 PN25 365 25 Note:1. Factory pressure testing: Each valve is tested at 1.6 of pressure rating.2. Water Temperature: 0.5 - 50ºC (33 - 122ºF)3. Standard flange facing: Raised Face (RF), Serrated Finish. Flat Face (FF) flanges available on request.Pressure Rating 2 1 2 3 4 5 6 7 8 9 10 9 19 18 17 16 15 14 13 12 11 BERMAD Fire Protection 700 Series FP 700E Flow & Hydraulic Data gpm Flow Rate Pr essur e Los s 0.1 1.0 10 100 1,000 0.5 40 65 50 500 5,000 psi 15.0 12.5 10.0 7.5 5.0 2.5 1.5 50 75 100 250 500 750 1,000 2,500 20,000 15,000 10,000 5,000 7,500 m3/h bar 1 1 /2 ”2 1 /2 ”2 ”50 80 3 ”100 4 ”150 6 ”200 8 ”250 10 ”300 12 ”350 14 ”400 16 ”Flow Chart Flow Properties DN 40-50 65 80 100 150 200 250 300 350 400 Inch 1½"-2”2½"3"4"6"8"10"12"14"16"“Y”-Type Kv-Y 50 55 115 200 460 815 1,250 1,850 1,990 3,310 Cv-Y 58 64 133 230 530 940 1,440 2,140 2,300 3,820 K-Y 3.9 9.2 4.9 3.9 3.7 3.8 3.9 3.7 5.9 3.7 Leq-m, Y 10.3 33.4 21.6 23 37.5 53.9 70 85.6 159.9 112.7 Leq-feet, Y 33.8 109.5 70.8 75.6 123 176.9 229.5 280.8 524.5 369.6 Angle Kv-A 55 61 127 220 506 897 1,375 2,035 2,189 3,641 Cv-A 64 70 146 250 580 1,040 1,590 2,350 2,530 4,210 K-A 3.2 7.6 4.0 3.2 3.1 3.1 3.2 3.1 4.9 3.0 Leq-m, A 8.5 27.6 17.8 19.0 37.0 44.6 57.8 70.7 132.1 93.1 Leq-feet, A 28 90.5 58.5 62.5 101.6 146.2 189.7 232 433.4 305.5 Valve flow coefficient, Kv or Cv Equivalent Pipe Length, Leq Flow resistance or Head loss coefficient,Cv = 1.155 Kv Where:Kv = Valve flow coefficient (flow in m 3 /h at 1bar Diff. Press.)Cv = Valve flow coefficient (flow in gpm at 1psi Diff. Press.)Q = Flow rate (m 3 /h ; gpm)∆P = Differential pressure (bar ; psi) Gf = Liquid specific gravity (Water = 1.0) Kv(Cv)=Q G f ∆P Leq=Lk .D K=∆H 2g V 2 Where:K = Flow resistance or Head loss coefficient (dimensionless)∆H = Head loss (m ; feet)V = Nominal size flow velocity (m/sec ; feet/sec.)g = Acceleration of gravity (9.81 m/sec 2 ; 32.18 feet/sec 2 )Where:Leq = Equivalent nominal pipe length (m ; feet)Lk = Equivalent length coefficient for turbulent flow in clean commercial steel pipe (SCH 40)D = Nominal pipe diameter (m; feet)Note:The Leq values given are for general consideration only.Actual Leq may vary somewhat with each of the valve sizes. 3 Design Criteria BERMAD Fire Protection 700 Series FP 700E Dimensions & Weights Size DN mm (inch)40 (1½”)50 (2”)65 (2½”)80 (3”)100 (4”)150 (6”)200 (8”)250 (10”)300 (12”)350 (14”)400 (16”)ANSI #150, ISO PN 16 L (mm)10 205 222 250 320 415 500 605 725 733 990 LG (4)(mm)N/A N/A N/A 250 320 415 500 N/A N/A N/A N/A W (mm) 165 165 178 200 223 320 390 480 550 550 740 R (mm) 78 83 95 100 115 143 172 204 242 268 300 La (mm) 124 124 149 152 190 225 265 320 396 400 450 ha (inch) 85 85 109 102 127 152 203 219 273 279 369 Hy (inch) 239 244 257 305 366 492 584 724 840 866 1,108 Ha (inch)227 227 241 281 342 441 545 633 777 781 1,082 Weight Y (kg) 10.6 10.6 13 22 37 75 125 217 370 381 846 Weight A (kg) 10 10 12 21.5 35 71 118 205 350 370 800 ANSI #300, ISO PN 25 L (mm)210 210 222 264 335 433 524 637 762 767 1,024 W (mm) 165 165 185 207 250 320 390 480 550 570 740 R (mm) 78 83 95 105 127 159 191 223 261 295 325 La (mm) 124 124 149 159 200 234 277 336 415 419 467 ha (inch) 85 85 109 109 127 165 216 236 294 299 386 Hy (inch) 239 244 257 314 378 508 602 742 859 893 1,133 Ha (inch)227 227 251 287 650 454 558 649 796 801 1,099 Weight Y (kg) 12.2 12.2 15 25 43 85 146 245 410 434 900 Weight A (kg) 11.5 11.5 13.5 23 41 81 138 233 390 421 855 Ports a (1) (mm)½½½½½½½½½½½b (1) (mm) ½½½½½½½½½½½c (1) (mm) ¾¾¾¾¾2 2 2 2 2 2 d (2) (optional)(mm) ¾¾1½1½2 2 2 2 2 2 2 Control Vol. (3)(Liter) 0.125 0.125 0.125 0.3 0.45 2.15 4.5 8.5 12.4 12.4 29.9 Metric Si Flanged d L & LG R Hy a c b a La Ha a ha c b a b c W b c Y Body Type Angle Body Type (1) (a), (b), (c) are NPT thread ports (2) (d) is BSPT threaded Optional drain port (3) (Control Volume) is Control Chamber Displacement Volume of liquid pushed when valve opens (4) LG for Grooved ends (see available sizes)4 BERMAD Fire Protection 700 Series FP 400E Dimensions & Weights Size (inch)1½”2”2½”3”4”6”8”10”12”14”16”ANSI #150, ISO PN 16 L (inch)8.1 8.1 8.3 9.8 12.6 16.3 19.7 23.8 28.5 28.9 39.0 LG (4)(inch)N/A N/A N/A 9.8 12.6 16.3 19.7 B/A B/A B/A B/A W (inch) 6.1 6.1 7.0 7.9 8.8 12.6 15.4 18.9 21.7 21.7 29.1 R (inch) 3.1 3.3 3.7 3.9 4.5 5.6 6.8 8.0 9.5 10.6 11.8 La (inch) 4.9 4.9 5.9 6.0 7.5 8.9 10.4 12.6 15.6 15.7 17.7 ha (inch) 3.3 3.3 4.3 4 5 6 8 8.6 10.7 11 14.5 Hy (inch) 9.4 9.6 10.1 12 14.4 19.4 23 28.5 33.1 34.1 43.6 Ha (inch)8.9 8.9 9.9 11.1 13.5 17.4 21.5 24.9 30.6 30.7 42.6 Weight Y (lb) 23 23 29 49 82 165 276 478 816 840 1,865 Weight A (lb) 22 22 27 47 77 157 260 452 772 216 1,764 ANSI #300, ISO PN 25 L (inch)8.3 8.3 8.7 10.4 13.2 17 20.6 25.1 30 30.2 40.3 W (inch) 6.5 6.5 7.3 8.1 9.8 12.6 15.4 18.9 21.7 22.4 29.1 R (inch) 3.1 3.3 3.7 4.1 5 6.3 7.5 8.8 10.3 11.6 12.8 La (inch) 4.9 4.9 5.9 6.3 7.9 9.2 10.9 13.2 16.3 16.5 18.4 ha (inch) 3.3 3.3 4.3 4.3 5.3 6.5 8.5 9.3 11.6 11.8 15.2 Hy (inch) 9.4 9.6 10.1 12.4 14.9 20 23.7 29.2 33.8 35.2 44.6 Ha (inch)8.9 8.9 9.9 11.3 13.8 17.9 22 25.6 31.3 31.5 43.3 Weight Y (lb) 27 27 33 55 95 187 322 540 904 957 1,984 Weight A (lb) 25 25 30 51 90 179 304 514 860 928 1,88 Ports a (1) (inch)½½½½½½½½½½½b (1) (inch) ½½½½½½½½½½½c (1) (inch) ¾¾¾¾¾2 2 2 2 2 2 d (2) (optional)(inch) ¾¾1½1½2 2 2 2 2 2 2 Control Vol. (3)(Gal.) 0.04 0.04 0.04 0.08 0.12 0.57 1.19 2.25 3.28 3.28 7.88 English US Flanged d L & LG R Hy a c b a La Ha a ha c b a b c W b c Y Body Type Angle Body Type (1) (a), (b), (c) are NPT thread ports (2) (d) is BSPT threaded Optional drain port (3) (Control Volume) is Control Chamber Displacement Volume of liquid pushed when valve opens (4) LG for Grooved ends (see available sizes) 5 BERMAD Fire Protection 700 Series FP 700E Installation, Operation & Maintanence Electr ic Pneumatic Hydraulic Electr ic Pneumatic Hydraulic Valve Closed (Set Position)Line pressure applied to the upper control chamber of the valve creates a superior force that moves the valve to the closed position and provides drip tight sealing. Valve Open (Operating Conditions)Releasing the pressure from the upper control chamber to atmosphere or some other lower pressure zone causes the line pressure acting on the seal disc to move the valve to the open position.Proper operation of the 700E Deluge Valves depends upon their trim being installed in accordance with the appropriate trim configuration.Notes: ■ Wet pilot height should not exceed “Maximum Elevation Above Valve” (see data for specific model).■ Any deviation in trim size or arrangement may adversely affect the proper operation of the deluge valve. ■ All the pilot system devices, must be UL Listed and compatible with the particular deluge system. Refer to current “UL Listed Fire Protection Equipment Directory”.Warning: The deluge valve and trim must be installed only in areas where they will not be subject to freezing temperatures.Installation Instructions 1. Allow enough room around the valve assembly for any adjustments and future maintenance.2. Before the valve is installed, flush the pipeline to remove any dirt, scale, debris, etc. Not flushing the line may result in the valve’s becoming inoperable.3. Install the valve in the pipeline so that the valve flow arrow appearing on the body casting is pointing in the desired direction. Ensure that the valve is positioned so that the actuator assembly can be easily removed for future maintenance.4. Ensure that the Control Trim is mounted properly and all other components are positioned correctly as per illustration.5. After installation in the main line, carefully inspect/correct any damaged accessories, piping, tubing, or fittings. Ensure that there are no leaks.6. Install the components comprising the Deluge Trim Package in their proper positions in compliance with all instructions, drawings, and technical specifications describing the BERMAD Deluge Valve, according to the relevant illustration.7. All additional accessories, although not packed together with the BERMAD Deluge Valve, must be installed as shown in the relevant P&ID and other illustrations.Operation Principle of Operation The BERMAD 700E Deluge Valve (assembled with specific trim) is suitable for systems that include adequate detecting and piping systems with open nozzles. The deluge valve prevents water from entering system piping until required. The deluge valve is kept closed by pressure applied to the upper control chamber through a restricted priming line.In the SET position, the water pressure supplied through the priming line is trapped in the upper control chamber of the deluge valve by a check valve, and by the normally closed release device.The pressure trapped in the upper control chamber of the deluge valve presses the valve seal disk down, thereby sealing the valve and keeping the system piping dry.Under conditions of FIRE, when the pressure is released from the upper control chamber by the opening of the automatic releasing device or by manual release, the deluge valve opens and allows the inlet supply water to flow through the valve and into the system piping and alarm devices.Warning: Whenever the handle of the Manual Emergency Release is pulled, pressure is released from the upper control chamber, the deluge valve will open, and water will flow into system piping and alarm devices.Installation 6 BERMAD Fire Protection 700 Series FP 700E Installation, Operation & Maintanence Placing in Service/Resetting The deluge valve and the control trim shall be Placed in Service with accordance to the most recent IOM procedures for the specific model. After all relevant instructions are performed, slowly open the supply-isolating valve and check that no water flows into the system.The system is now operational and in stand-by mode.Maintenance Bermad Deluge Valves require no lubrication, no packing tightening, and require a minimum of maintenance. Removing the System from Service Warning: When taking a deluge system out of service, a fire patrol should be established in the system area. If automatic fire alarm signaling equipment is utilized, the proper authority should be notified that the system is being removed from service. The insuring body and owner’s representative should also be notified when the system is being taken out of service.Removal Instructions 1. Shut off the main supply-isolating valve.2. Close the priming line valve to the deluge valve control chamber.3. Open all drain valves.4. Release the water pressure from the control chamber of the deluge valve by pulling the manual emergency release.5. Place "Fire Protection System Out of Service" signs in the area protected by the system.Inspection and Testing 1. Warning:Do not turn off the water supply to make repairs without placing a roving fire patrol in the area covered by the system. The patrol should continue until the system is back in service. 2. Prior to turning off any valves or activating any alarms, notify local security guards and the central alarm station, if used, to avoid signaling a false alarm. 3. The deluge valve and the control trim shall be maintained with accordance to the most recent IOM procedures for the specific model. A periodic test schedule should be established also with accordance to the site conditions and owner regulations. 4. Take all additional measures as required by NFPA-25 “standard for the inspection, testing, and maintenance of water-based fire protection systems”. 5. The system should be checked weekly for “Normal Conditions”.6. Clean the priming strainer prior to any resetting of the deluge valve. 7. The deluge valve must be activated at full flow at least annually. Take all necessary precautions to drain water and prevent damage in the area protected by the system.8. After about five years of operation, replacement of diaphragm and other elastomers is recommended. Remove the actuator and disassemble it. Clean the seat area from sediments, clean the control tubing entry holes, and install a new diaphragm and other elastomers in place.Spare Parts 1. The Diaphragm and the Seals are the only spare parts needed for the main deluge valve, see attached “Valve Disassembly and Parts Breakdown” illustration.2. It is not recommended to store spare rubber parts for long periods (rubber in improper storage conditions can harden and crack). 3. Contact your Bermad representative and order new rubber parts when required.7 BERMAD Fire Protection 700 Series Bea r ing Ass em b l y Shaft Diaph r agm W asher O-Ring Diaph r agm Spacer Disk Diaph r agm W asher Nut Indicator Lo c k Nut C o v er Disk Bolt C o v er Plug (6 ” and up)O-Ring E y e Nut Bea r ing Scr e w Disk Sepa r ation P a r tition Bolt Stud Nut Lo c king Scr e w Seal Disk Assem b l y Seal Disk W ash.Scr e w Seal Seal Disk O-Ring Sp r ing Nut Actuator Assem b ly Scr e w Rem o v a b le Seat Nut Y Body T ype Angle Body T ype FP 700E Installation, Operation & Maintanence Valve Disassembling Parts Breakdown bermadfire@bermad.com • www.bermad.com The information herein is subject to change without notice. BERMAD shall not be held liable for any errors. All rights reserved. © Copyright by BERMAD. PT7PE04-DATA 8 ES-F-860L SPECIFICATION SHEET FEBCO product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise mea -surements, please contact FEBCO. FEBCO reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on FEBCO products previously or subse -quently sold.Job Name ––––––––––––––––––––––––––––––––––––––––––– Contractor ––––––––––––––––––––––––––––––––––––––––––––Job Location ––––––––––––––––––––––––––––––––––––––––– Approval –––––––––––––––––––––––––––––––––––––––––––––Engineer –––––––––––––––––––––––––––––––––––––––––––– Contractor’s P.O. No. ––––––––––––––––––––––––––––––––––Approval –––––––––––––––––––––––––––––––––––––––––––– Representative ––––––––––––––––––––––––––––––––––––––––MasterSeries ® 860 Reduced Pressure Zone Assemblies Size: 2 1 ⁄2 " - 10" (65mm - 250mm) The FEBCO Master Series ® 860 Reduced Pressure Zone Assemblies are designed for health hazard applications. End connections – Flanged ANSI B16.1 Class 125 Pressure – Temperature Max. Working Pressure: 175psi (12.1 bar) Hydrostatic Test Press: 350psi (24.1 bar) Temperature Range: 32°F to 140°F (0°C to 60°C)Materials Main Valve Body: Ductile iron Grade 65-45-12 Coating: Fusion epoxy coated internal and external AWWA C550 Shutoff Valves: NRS and OS&Y resilient wedge gate valves AWWA C509 Trim: Bronze Elastomer Discs: EPDM Spring: Stainless steel Clamp: AWWA C606 (10" only, 250mm)Approvals – Standards • ANSI/AWWA (C511) - 2 1 ⁄2 " - 10" • Approved by the Foundation for Cross-connection Control and Hydraulic Research at the University of Southern California. - 2 1 ⁄2 " - 8" (65 - 200mm)Typical Installation MODEL 860 REDUCED PRESSURE ASSEMBLY Model 860 / Typical Installation 2 1 ⁄2 "3"Capacity 2 1 ⁄2 " & 3" (65 mm & 80 mm ) kPa psi 138 20 103 15 69 10 34 5 0 80 160 240 320 400 gpm 0 304 606 910 1211 1520 lpm H EADLOSS 4" & 6" (100 mm & 150 mm ) kPa psi 138 20 103 15 69 10 34 5 0 400 800 1200 1600 2000 gpm 0 1520 3040 4540 6060 7600 lpm H EADLOSS 8" & 10" (200 mm & 250 mm ) kPa psi 138 20 103 15 69 10 34 5 0 1000 2000 3000 4000 5000 gpm 0 3800 7600 11400 15140 19000 lpm H EADLOSS 1013 2 1 ⁄2 " - 10" 65 - 250mm B64.4 2 1 ⁄2 " - 8" 65 - 200mm 2 1 ⁄2 " - 8" 65 - 200mm 2 1 ⁄2 " - 8" 65 - 200mm S iz E (DN)Di MENS i ONS W E ig H t A B C D E F G H NRS OS&Y in.mm in.mm in.mm in.mm in.mm in.mm in.mm in.mm in.mm lbs.kgs.lbs.kgs.2 1 ⁄2 65 40 3 ⁄4 1035 25 1 ⁄2 648 12 5 ⁄8 321 10 254 12 7 ⁄8 327 10 254 4 1 ⁄2 114 7 1 ⁄8 181 219 99 223 101.2 3 80 41 7 ⁄8 1064 25 5 ⁄8 651 12 7 ⁄8 327 10 254 13 330 10 254 4 1 ⁄2 114 7 3 ⁄8 187 231 105 233 105.7 4 100 46 1 ⁄4 1175 28 711 14 3 ⁄8 365 10 1 ⁄8 257 15 1 ⁄8 384 10 1 ⁄8 257 5 1 ⁄2 140 8 1 ⁄8 206 317 144 334 151.5 6 150 56 1422 34 3 ⁄4 883 18 7 ⁄8 479 12 3 ⁄4 324 20 3 ⁄4 527 11 1 ⁄8 283 6 1 ⁄2 165 9 7 ⁄8 251 481 218 516 234.1 8 200 65 1651 41 3 ⁄4 1061 23 1 ⁄2 570 15 5 ⁄8 397 26 7 ⁄8 683 12 1 ⁄4 311 7 178 11 1 ⁄8 283 734 333 796 361.1 10 250 72 5 ⁄8 1845 46 3 ⁄8 1178 27 1 ⁄2 699 15 5 ⁄8 397 28 1 ⁄4 718 12 3 ⁄8 314 9 229 12 3 ⁄8 314 946 429 1008 457.2 Note: Dimensions shown are nominal. Allowances must be made for normal manufacturing tolerances.Dimensions – Weight Size: 2 1 ⁄2 " - 10" (65 - 80mm) ITEM D ES cr I p TI on Ma TE r I al 1 Body A536 GR 65-45-12 1.1 Pipe Plug Galv. Stl. 1.2 Bushing (2 1 /2 "-4" Only) Brass 2 Cover A536 GR 65-45-12 2.1 O-Ring EPDM ASTM D2000 2.2 Cap Screw Plated Steel 2.3 Hex Nut Plated Steel 3 Seat Ring B584 Alloy C83600 3.1 Gasket EPDM ASTM D2000 3.2 Socket Head Screw 18-8-SS 3.3 Washer 304 SS 3.4 Elastic Stop Nut 18-8-SS 4 Arm B584 Alloy C83600 4.1 Bushing-Swing Pin Acetal Resin 4.2 Swing Pin 304 SS 5 Retaining Clip 302 SS 5.1 Retaining Clip 302 SS 6 Check Disk EPDM Coated GR, 45 Ductile Iron with A276 type 304SS stem 7 Load Pin B150 Alloy C61300 8 Lwr Spring Retnr B584 Alloy C83600 9 Spring Stem 304 SS 9.1 Elastic Stop Jam Nut 18-8 SS 10 Spring A313 Type 631 SS 10.1 Spring 2nd Check A313 Type 631 SS 10.2 Spring Shim 2nd Check Acetal Resin 11 Spring Guide B130 Alloy C22000 12 Upr Spring Retnr B584 Alloy C83600 12.1 Bushing-Spr. Stem Acetal Resin 13 Pivot Bearing B585 Alloy C83600 14 Flange Gasket Rubber/Fabric 15 Bearing Socket Acetal Resin 16 Hex Jam Nut 18-8 SS 17 Washer 302 SS 18 Flange Nut Plated Steel 18.1 Flange Nut Plated Steel 20 R.V. Cover B584 Alloy C83600 20.1 Bleed Screw 18-8 SS 20.2 Gasket HDPE 21 R.V. Body B584 Alloy C83600 22 Cover Bolt 18-8 SS 23 Elbow A536 GR 65-45-12 24 RV Mtg Bolt Plated Steel 24.1 Washer Plated Steel 25 RV Mtg Nut Plated Steel 26 Gasket EPDM 27 Lrg. Diaphragm Nitrile ASTM D2000 28 Button A240 304 SS 28.1 Flow Washer Acetal Resin 29 RV Spring A313 Type 302 SS 30 RV Stem Acetal Resin 31 Main Guide B584 Alloy C83600 31.1 Main Guide O-Ring FDA EPDM 32 Seat Disc EPDM AST D2000 33 Lower Guide Acetal Resin 34 Seat Ring B584 Alloy C83600 34.1 O-ring FDA EPDM 35.1 O-Ring EPDM ASTM D2000 35.2 Extension Acetal Resin 37 Sm. Diaphragm Nitrile ASTM D2000 38 Retainer B584 Alloy C83600 38.1 Slip Ring Acetal Resin 39 Flow Washer Acetal Resin 40 Ball Valve B584 Alloy C84400 41 Nipple Brass 41.1 Nipple Brass 41.2 Nipple Brass 42 Gate Valve (NRS) AWWA C509 60 Identification Plate B36 Alloy C26000 62 Drive Screw Stainless Steel 70 Clamp AWWA C606 (10" Only)Series 860 / Materials of Construction Top View n ote: The gap drain is not designed to catch the maximum discharge pos -sible from the relief valve. The installation of FEBCO air gap with the drain line terminating above a floor drain will handle any normal discharge or nui -sance spitting through the relief valve. However, floor drain size may need to be designed to prevent water damage caused by a catastrophic failure condition. Do not reduce the size of the drain line from the air gap fitting.USA: Fresno, CA • Tel: (559) 441-5300 • Fax: (559) 441-5301 • www.FEBCOonline.com Canada: Burlington, ON • Tel: (905) 332-4090 • Fax: (905) 332-7068 • www.FEBCOonline.ca ES-F-860L 1119 © 2011 FEBCO A Watts Water Technologies Company g C F A B E D H AHEAD OF THE FLOW TM Copper Fittings CATALOG C-CF-0404 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH:1.888.446.4226 • FAX: 1.800.336.4226 • INTERNATIONALOFFICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com NIBCO flow-control solutions are everywhere you look, including on our website. We offer a wide range of metal and plastic valves and fittings that keep residential, commercial and industrial operations flowing smoothly throughout the world.Compact Economy Ball Valves Prepackaged Pneumatic Ball Valves Circuit Balancing Valves Flanged Butterfly Valves Bronze Ball Valve Line Extension PEXlink ®copper fittings for PEX applications Just Right ®hot-water circulation device Carbon/Stainless Steel Ball Valves Socket Fusion Equipment TruConnect ®fittings for Chem-Aire ®The "New Products" page is a continuously updated showcase for new products by NIBCO.*Current highlights include:ORDERONLINE NIBCOpartner.com makes it easy for you to order all the fittings you need right from your own computer. Its quick, easy and reliable.Place your order TODAY!Price sheets (PDF & Excel format)—also accessible from home page Downloadable catalogs (PDF format)Product drill-down capabilities to categories Wrot Copper & Cast Bronze Fittings ABS & PVC Drain, Waste, & Vent PVC Schedule 40 Fittings & Valves CPVC CTS Fittings The “Fittings” Homepage at www.nibco.com provides easy access to valuable reference tools.*Key information includes: AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 3 Table of Contents Cast Copper Alloy Flared Fittings . . . . . . . . . . . . . . . . . . . . . . . . . .22-24 Copper Insert Fittings for PEXlink ™ . . . . . . . . . . . . . . . . . . . . . . . . .25-27 Copper Insert Fittings for Polybutylene . . . . . . . . . . . . . . . . . . . . .28-29 Engineering Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41-84 Frequently-Asked Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90 Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85-89 Numerical Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91 Wrot & Cast DWV Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30-40 Wrot & Cast Pressure Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-21 The manufacturing plants at South Glens Falls, NY, Stuarts Draft, VA, Nacogdoches, TX and Reynosa, Mexico manufacture products under a Quality Management System conforming to the current revision of ISO-9001 International Standards AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 4 All of the advantages found in copper as a metal have been capitalized to the utmost in the manufacture of NIBCO Fittings. Beca use of the accuracy of construction and design, copper plumbing is more efficient and less expensive.NIBCO manufactures nine general types of fittings: Wrot Pressure; Cast Pressure; Wrot Drainage; Cast Drainage; Flanges; Flared Tube; Threaded Bronze; Insert Fittings for PEX; Barbed Insert Fittings for Polybutylene. Each has its particular place and use and each offers its own advantages when used for the proper service requirement.ALLOY AND FINISH — NIBCO Fittings are made from highest quality raw materials available — Cast Fittings are made from Copper Alloy C84400 which consists of 81% Copper, 7% Lead, 3% Tin, and 9% Zinc per ASTM Specification B584. Wrot Copper Fittings are made from commercially pure copper mill products per ASTM Specifications B75 Alloy C12200.NIBCO fittings are produced to meet requirements of applicable standards wherever practicable.NIBCO brand wrot and cast fittings are manufactured in the U.S.A. and Mexico. The manufacturing plants at South Glens Falls, NY ,Stuarts Draft, VA, Nacogdoches, TX and Reynosa, Mexico are registered to ISO 9002 quality standards.Following is suggested phrasing to be incorporated in your specifications or bills of material for Copper Tube Fittings.WROT SOLDER JOINT FITTINGS — “Wrot Solder Joint Fittings shall be produced to one of the following specifications:1.Material and workmanship shall be in accordance with ASME/ANSI B16.22; Wrought Copper and Copper Alloy Solder Joint Pressure Fittings.”Specifications 2.The dimensional, material and workmanship shall meet the requirements of MSS SP-104; Wrought Copper Solder Joint Pressure Fittings.”3.The dimensional, material and workmanship of 5"–12" copper fittings shall meet the requirements of MSS SP-109 “Welded Fabricated Copper Solder Joint Pressure Fittings.”4.Certified to ANSI/NSF 61.CAST COPPER ALLOY SOLDER JOINT FITTINGS —“Cast Copper Alloy Solder Joint Fittings shall be in accordance with ANSI Std. B16.18.”WROT DRAINAGE FITTINGS — “Wrot Drainage Fittings shall be in accordance with ASME/ANSI Std.B16.29.”CAST COPPER ALLOY SOLDER JOINT DRAINAGE FITTINGS — “Cast Copper Alloy Solder Joint Drainage Fittings shall be in accordance with ASME Std.B16.23.”CAST COPPER ALLOY FLARED TUBE FITTINGS — “Cast Copper Alloy Flared Tube Fittings shall be in accor-dance with ASME/ANSI Std. B16.26.CAST COPPER ALLOY FLANGES AND FLANGED FITTINGS—CLASS 150 — Cast Copper Alloy Flanges and Flanged Fittings shall meet the requirements of MSS SP-106 and/or the workmanship and dimensions of Federal Specifications WW-F-406 or ASME Std. B16.24.CLASS 125 — Material, workmanship and dimensions of flanges shall be in accordance with MSS SP-106.CAST BRONZE THREADED FITTINGS — “Cast Bronze Threaded Fittings shall be in accordance with ANSI/ASME B16.15.”POLYBUTYLENE COPPER INSERT TYPE VALVES AND FITTINGS — “Wrot Copper Insert Fittings shall be manufactured per the following specifications: MSS SP-103 or ASTM F1380.”NIBCO Copper Tube Fittings are all produced to above Standards. To simplify, write your specifications to read: “Copper Tube Fittings to be in accordance with specifications as outlined in NIBCO Catalog c-cf-0602.”WROT COPPER MEDICAL MEDICAL GAS SYSTEM COMPONENTS — Wrot copper fittings that are to be installed in medical gas applications shall be prepared in accordance with NFPA 99, Health Care Facilities Gas and Vacuum Systems and the Compressed Gas Association, Pamphlet G4.1. Packaging shall be adequately protective and include labeling that identifies the preparer and states that the product has been cleaned and bagged for oxygen or med gas service.For technical information and dimensions refer to the engineering section contained in this catalog. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 5 Wrot and Cast Pressure Fittings 600 Series – Wrot 700 Series – Cast Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-8 Air Chambers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Bulkhead Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Bushings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-11 Crosses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-15 Fitting Reducers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Flanges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15-16 Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Return Bends . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Straps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Tees . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16-20 Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Unions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Venturi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Y’s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 The manufacturing plants at South Glens Falls, NY, Stuarts Draft, VA, Nacogdoches, TX and Reynosa, Mexico manufacture products under a Quality Management System conforming to the current revision of ISO-9001 International Standards 7 03-2 Fitting Adapter Ftg x F – Cast APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1/2 x 1/4 0.111 7 /32 3/4 x 1/2 0.121 9 /16 1 x 3/40.381 31 /32 1 x 1/2 0.151 7 /16 2 1/21.652 15 /16 32.473 1 /4 703-5 Special Drop Adapter C x F – Cast APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/2 0.16 3 /4 3/4 0.24 31 /32 703-5B Drop Adapter C x F – Cast APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/2 0.15 3 /4 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 6 ADAPTERS 603 Adapter C x F – Wrot APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/8 0.03 13 /32 1/8 x 1/40.03 1 /2 1/40.03 5 /8 1/4 x 3/80.05 21 /32 3/80.04 11 /16 3/8 x 1/20.09 29 /32 3/8 x 1/40.03 9 /16 1/20.09 27 /32 1/2 x 3/40.141 1/2 x 3/80.04 17 /32 1/2 x 1/4 0.05 1 /2 5/8 x 3/40.12 29 /32 5/8 x 1/20.11 3 /4 3/40.15 29 /32 3/4 x 10.211 1 /8 3/4 x 1/20.10 5 /8 10.24 31 /32 1 x 1 1/40.281 7 /32 1 x 3/40.19 25 /32 1 x 1/20.24 5 /8 1 1/40.331 3 /32 1 1/4 x 1 1/20.401 1 /4 1 1/4 x 10.27 31 /32 1 1/20.441 1 /8 1 1/2 x 20.501 1 /32 20.631 3 /32 2 x 1 1/20.741 3 /16 2 1/21.13–31.94–703 Adapter C x F – Cast APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/4 x 1/20.13 27 /32 1/2 x 10.301 3/4 x 1 1/40.551 1 /8 3/4 x 3/80.17 3 /4 1 x 1 1/20.68 13 /32 1 1/4 x 10.27 31 /32 1 1/4 x 3/40.29 3 /4 1 1/2 x 20.781 1 /32 1 1/2 x 10.37 25 /32 1 1/2 x 1 1/40.471 1 /4 2 x 1 1/40.76 27 /32 2 1/21.621 3 /8 32.341 1 /2 44.051 9 /16 603-2 Fitting Adapter Ftg x F – Wrot APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1/40.031 3 /32 3/80.061 3 /16 1/20.091 7 /16 1/2 x 3/80.051 1 /4 3/4 0.131 11 /16 10.272 1 /32 1 1/4 0.312 1 /8 1 1/2 0.432 5 /16 20.612 17 /32 Consult price sheet for Made to Order items and for minimum order quantities. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 7 ADAPTERS continued 604 Adapter C x M – Wrot APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1/8 x 1/40.03 7 /16 1/40.03 23 /32 3/80.04 15 /32 3/8 x 3/40.151 5 /16 3/8 x 1/20.091 1/20.07 5 /8 1/2 x 10.251 1 /2 1/2 x 3/40.15 13 /16 1/2 x 3/80.05 19 /32 1/2 x 1/40.07 5 /8 5/8 x 3/40.161 1 /8 5/8 x 1/20.08 3 /4 3/40.14 13 /16 3/4 x 10.261 7 /16 3/4 x 1/20.10 27 /32 10.21 31 /32 1 x 1 1/20.54 29 /32 1 x 1 1/40.381 1 /2 1 x 3/40.18 29 /32 1 x 1/20.18 31 /32 1 1/40.35 15 /16 1 1/4 x 1 1/20.511 19 /32 1 1/4 x 10.271 5 /32 1 1/20.44 31 /32 1 1/2 x 20.811 1 /8 1 1/2 x 1 1/40.381 3 /16 1 1/2 x 10.371 3 /32 20.811 3 /32 2 x 1 1/20.641 1 /8 2 1/21.481 21 /32 31.69–Consult price sheet for Made to Order items and for minimum order quantities.704 Adapter C x M – Cast APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 3/4 x 1 1/20.601 17 /32 3/4 x 1 1/40.381 7 /32 3/4 x 3/80.19 13 /16 1 x 21.15–1 x 1 1/20.64 29 /32 1 1/4 x 20.881 9 /32 1 1/4 x 3/40.30 31 /32 1 1/2 x 20.771 1 /8 2 x 2 1/21.571 15 /32 2 x 1 1/20.711 1 /8 2 x 1 1/41.08–2 1/21.481 21 /32 2 1/2 x 21.831 11 /16 31.961 1 /2 43.661 11 /16 58.602 5 /8 610.732 704-F Flush Adapter C x M – Cast APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1/20.03 9 /16 3/40.03 19 /32 704-H Hose Adapter C x Hose – Cast APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/20.09 9 /32 NOTE: Fits 1 /2 ," 5 /8 " and 3 /4 " Garden Hose.604-2 Fitting Adapter Ftg x M – Wrot APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1/80.021 1 /8 3/80.041 1 /4 1/20.091 15 /32 1/2 x 3/40.161 13 /16 1/2 x 3/80.041 11 /32 3/40.171 15 /16 10.252 1 /4 704-2 Fitting Adapter Ftg x M – Cast APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 3/4 x 10.271 31 /32 3/4 x 1/20.121 23 /32 1 x 3/40.241 15 /16 1 1/40.432 27 /32 1 1/20.542 13 /32 20.892 3 /4 2 1/21.553 3 /8 32.213 23 /32 750 Bulkhead Fitting C x C – Cast APPROX.DIM. ADIM. B NOM. SIZENET WT./LBS.INCHESINCHES 1/20.481 1 /4 1 3/40.771 9 /32 1 1 /4 11.301 1 /2 1 5 /8 1 1/22.871 1 /2 2 3 /8 23.822 1 /32 2 5 /8 750-3 Bulkhead Fitting C x F – Cast APPROX.DIM. ADIM. B NOM. SIZENET WT./LBS.INCHESINCHES 1/20.481 15 /16 1 3/40.792 1 /16 1 1 /4 11.432 15 /32 1 5 /8 750-4 Bulkhead Fitting C x M – Cast APPROX.DIM. ADIM. B NOM. SIZENET WT./LBS.INCHESINCHES 1/20.401 31 /32 1 3/40.792 5 /32 1 1 /4 704-2-H Hose Adapter Ftg x Hose–Cast APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 3/4 F x 1/2 H0.161 5 /8 NOTE: Fits 1 /2 ," 5 /8 " and 3 /4 " Garden Hose.619 Air Chamber Ftg. – Wrot APPROX.DIM. ADIM. L NOM. SIZENET WT./LBS.INCHESINCHES 1/2 x 60.2116 1/2 x 120.41112 1/2 x 140.781 1 /8 14 3/4 x 120.40112 620-L Air Chamber or Stub-Out Ftg – Wrot As Air Chamber, just solder one joint. When used as Stub-Out, simply pressure test system then cut off stub-out (save piece for future use) and install valve or fixture.APPROX.DIM. L NOM. SIZENET WT./LBS.INCHES 1/2 x 60.146 1/2 x 80.198 1/2 x 100.2410 1/2 x 120.2812 3/4 x 120.4612 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 8 AIR CHAMBERS BULKHEAD FITTINGS Consult price sheet for Made to Order items and for minimum order quantities.618 Flush Bushing Ftg x C – Wrot APPROX.DIM. C NOM. SIZENET WT./LBS.INCHES 1/4 x 1/80.01 1 /16 3/8 x 1/40.01 1 /16 1/2 x 3/80.02 3 /32 1/2 x 1/40.04 1 /4 5/8 x 1/20.03 1 /16 3/4 x 5/80.22 3 /16 3/4 x 1/20.08 3 /32 3/4 x 3/80.11 7 /16 1 x 3/40.12 1 /8 1 x 1/20.22 15 /32 1 1/4 x 10.17 3 /32 1 1/2 x 1 1/40.22 5 /32 2 x 1 1/20.66 1 /8 618-3 Flush Bushing Ftg x F – Wrot APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1/2 x 1/80.03 9 /16 1/2 x 1/40.03 9 /16 718-3 Flush Bushing Ftg x F – Cast APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 3/4 x 3/80.061 31 /32 1 x 1/20.13 31 /32 1 1/4 x 3/40.181 1 /32 1 1/2 x 10.251 5 /32 BUSHINGS ADAPTERS continued AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 9 Consult price sheet for Made to Order items and for minimum order quantities.CAPS 617 Tube Cap C – Wrot APPROX.DIM. N NOM. SIZENET WT./LBS.INCHES 1/80.01 1 /32 1/40.01 3 /32 3/80.01 3 /32 1/20.02 3 /32 5/80.03 1 /8 3/40.04 1 /8 10.07 5 /32 1 1/40.10 3 /32 1 1/20.16 1 /8 20.27 5 /32 2 1/20.50 7 /32 30.78 7 /32 41.66 1 /4 717 Tube Cap C – Cast APPROX.DIM. N NOM. SIZENET WT./LBS.INCHES 55.48 7 /16 69.07 17 /32 717-D Drain Cap – Cast APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/2 0.06 21 /32 COUPLINGS 600 Reducing Coupling C x C – Wrot APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/8 x 3/16 O.D.0.01 5 /32 5/16 O.D. x 1/80.01 3 /16 1/4 x 5/16 O.D.0.01 3 /16 1/4 x 1/80.01 3 /16 3/8 x 1/40.02 3 /16 3/8 x 5/16 O.D.0.01 1 /4 3/8 x 1/80.01 1 /4 1/2 x 3/80.03 3 /16 1/2 x 1/40.02 1 /4 1/2 x 1/80.03 11 /32 5/8 x 1/20.05 3 /16 5/8 x 3/80.04 11 /32 5/8 x 1/40.03 13 /32 3/4 x 5/80.07 3 /16 3/4 x 1/20.06 9 /32 3/4 x 3/80.06 3 /8 3/4 x 1/40.05 11 /32 1 x 3/40.11 11 /32 1 x 5/80.09 3 /8 1 x 1/20.10 11 /32 1 x 3/80.10 13 /32 1 1/4 x 10.16 5 /16 1 1/4 x 3/40.18 17 /32 1 1/4 x 5/80.18 5 /8 1 1/4 x 1/20.14 7 /16 1 1/2 x 1 1/40.23 5 /16 1 1/2 x 10.22 9 /16 1 1/2 x 3/40.20 3 /8 1 1/2 x 1/20.19 1 /2 2 x 1 1/20.41 9 /16 2 x 1 1/40.35 11 /16 2 x 10.37 7 /16 2 x 3/40.34 17 /32 2 x 1/20.35 23 /32 2 1/2 x 20.59 9 /16 2 1/2 x 1 1/20.65 11 /16 2 1/2 x 1 1/40.65 13 /16 2 1/2 x 10.73 29 /32 Continues…APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 3 x 2 1/20.98 1 /2 3 x 21.06 15 /16 3 x 1 1/20.921 1 /32 3 1/2 x 31.52 1 /2 4 x 3 1/22.12 19 /32 4 x 31.92 27 /32 4 x 2 1/21.771 4 x 21.921 1 /4 5 x 43.503 31 /32 5 x 33.181 15 /32 5 x 2 1/23.50 13 /16 5 x 23.092 1 /32 6 x 55.701 1 /8 6 x 45.241 1 /2 6 x 35.042 6 x 2 1/25.132 1 /4 6 x 24.892 1 /2 8 x 613.061 19 /32 8 x 412.222 19 /32 8 x 311.793 3 /32 8 x 2 1/212.643 3 /8 600-RS Coupling with Rolled Tube Stop C x C – Wrot APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/8 O.D.0.01 1 /16 3/16 O.D.0.01 3 /32 1/80.01 1 /16 5/16 O.D.0.01 3 /32 1/40.01 1 /16 3/80.01 3 /32 1/20.03 3 /32 5/80.04 3 /32 3/40.06 3 /32 7/80.09 3 /32 10.11 3 /32 1 1/40.16 1 /8 1 1/20.23 1 /8 20.41 1 /8 2 1/20.65 1 /8 30.93 1 /8 3 1/21.45 5 /32 41.93 7 /32 601 Coupling without Stop C x C – Wrot APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1/40.01 11 /16 3/80.01 27 /32 1/20.031 5/80.041 11 /32 3/40.061 19 /32 10.111 29 /32 1 1/40.162 1 /16 1 1/20.232 5 /16 20.412 13 /16 2 1/20.642 15 /16 30.863 5 /16 3 1/21.403 13 /16 41.844 5 /16 53.505 5 /16 65.606 3 /16 813.688 3 /32 701 Reducing Coupling C x C – Cast APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 3 x 1 1/41.35 23 /32 3 x 11.64 27 /32 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 10 COUPLINGS continued Consult price sheet for Made to Order items and for minimum order quantities.600-DS Coupling with Dimpled Tube Stop C x C – Wrot APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 3/16 O.D.0.01 3 /32 1/80.01 1 /16 5/16 O.D.0.01 3 /32 1/40.01 1 /16 3/80.01 3 /32 1/20.03 3 /32 5/80.04 3 /32 3/40.06 3 /32 7/80.09 3 /32 10.11 3 /32 1 1/40.16 1 /8 1 1/20.23 1 /8 20.41 1 /8 2 1/20.65 1 /8 30.93 1 /8 3 1/21.45 5 /32 41.93 7 /32 53.53 7 /32 65.63 7 /32 814.12 15 /32 701-D Drain Coupling C x C – Cast APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/2 0.08 1 /4 3/4 0.14 1 /4 10.22 1 /4 702 Eccentric Coupling C x C–Cast APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 3/4 x 1/20.10 17 /32 1 x 3/40.18 1 /4 1 1/4 x 10.25 1 /4 1 1/4 x 3/40.24 9 /32 724-5-A Hy-Set Hanger Coupling C – Cast APPROX.DIM. CDIM. D NOM. SIZENET WT./LBS.INCHESINCHES 1/20.051 5 /8 23 /32 3/40.091 5 /8 27 /32 10.131 5 /8 1 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 0 0 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 11 736 Cross-Over Coupling C x C – Cast APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/2 0.271 7 /16 3/4 0.601 29 /32 COUPLINGS continued 735 Cross C x C x C x C – Cast APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 3/80.09 3 /8 1/20.15 7 /16 3/40.30 9 /16 10.54 23 /32 1 1/40.78 7 /8 1 1/21.051 22.001 1 /4 2 1/22.961 1 /2 CROSSES ELBOWS 606 45°Elbow C x C – Wrot APPROX.DIM. CDIM. D NOM. SIZENET WT./LBS.INCHESINCHES 1/80.01 1 /4 1 /4 1/40.02 9 /32 9 /32 3/80.03 3 /16 3 /16 1/20.04 9 /32 9 /32 5/80.09 15 /32 15 /32 3/40.10 11 /32 11 /32 7/80.20 11 /16 11 /16 10.16 3 /8 3 /8 1 1/40.25 17 /32 17 /32 1 1/20.35 19 /32 19 /32 20.65 25 /32 25 /32 2 1/21.07 29 /32 29 /32 31.581 1 /8 1 1 /8 43.351 7 /16 1 7 /16 511.051 9 /16 1 9 /16 616.9522 823.002 9 /32 2 9 /32 606-2 45° Fitting Elbow Ftg x C – Wrot APPROX.DIM. BDIM. C NOM. SIZENET WT./LBS.INCHESINCHES 1/40.02 9 /16 1 /4 1/20.04 3 /4 7 /32 5/80.081 1 /8 13 /32 3/40.101 1 /16 5 /16 10.161 7 /32 15 /32 1 1/40.251 19 /32 17 /32 1 1/20.351 25 /32 19 /32 20.652 3 /16 25 /32 2 1/21.072 3 /16 29 /32 31.552 19 /32 1 5 /32 Consult price sheet for Made to Order items and for minimum order quantities. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 12 ELBOWS continued Consult price sheet for Made to Order items and for minimum order quantities.706-2 45° Fitting Elbow Ftg x C – Cast APPROX.DIM. BDIM. C NOM. SIZENET WT./LBS.INCHESINCHES 44.313 11 /32 15 /16 607 90° Elbow – Close Rough C x C – Wrot APPROX.DIM. CDIM. D NOM. SIZENET WT./LBS.INCHESINCHES 1/80.01 13 /32 13 /32 1/40.02 9 /32 9 /32 3/80.03 1 /2 1 /2 1/20.04 3 /8 3 /8 1/2 x 3/80.04 9 /16 21 /32 3/40.10 17 /32 17 /32 3/4 x 5/80.12 29 /32 7 /8 3/4 x 1/20.10 17 /32 3 /4 10.21 23 /32 23 /32 1 x 3/40.16 23 /32 5 /8 1 1/40.311 1 /32 1 1 /32 1 1/4 x 10.311 5 /8 1 15 /32 1 1/20.461 7 /32 1 7 /32 1 1/2 x 1 1/40.351 5 /32 1 3 /32 20.841 1 /2 1 1 /2 2 x 1 1/20.581 7 /16 1 1 /4 2 1/21.411 27 /32 1 27 /32 32.072 3 /32 2 3 /32 3 1/22.942 3 /8 2 3 /8 44.232 25 /32 2 25 /32 5 7.742 7 /8 2 7 /8 610.953 7 /16 3 7 /16 8 29.504 23 /32 4 23 /32 707 90°Elbow – Close Rough C x C – Cast APPROX.DIM. CDIM. D NOM. SIZENET WT./LBS.INCHESINCHES 1 1/4 x 10.421 5 /8 1 15 /32 1 1/4 x 3/40.34 9 /16 13 /16 1 1/4 x 1/20.28 15 /32 27 /32 1 1/2 x 10.54 11 /16 1 1 1/2 x 3/40.42 19 /32 31 /32 1 1/2 x 1/20.40 5 /8 29 /32 2 x 1 1/40.86 7 /8 1 1 /4 2 x 10.78 3 /4 1 1 /4 2 x 3/40.69 5 /8 1 1 /4 2 1/2 x 22.161 3 /16 19 /32 3 x 2 1/22.261 11 /16 1 1 /2 3 x 22.681 3 /8 1 9 /16 4 x 35.181 29 /32 2 15 /32 607-I 90°Elbow – Intermediate Radius C x C – Wrot APPROX.DIM. CDIM. D NOM. SIZENET WT./LBS.INCHESINCHES 1/20.06 19 /32 19 /32 5/80.09 7 /8 7 /8 3/40.14 13 /16 3 /16 10.241 1 /16 1 1 /16 607-LT 90°Elbow – Long Radius C x C – Wrot APPROX.DIM. CDIM. D NOM. SIZENET WT./LBS.INCHESINCHES 3/16 O.D.0.01 13 /32 13 /32 1/80.01 13 /32 13 /32 5/16 O.D.0.02 9 /16 9 /16 1/40.02 17 /32 17 /32 1/4 x 1/80.01 19 /32 1 /2 3/80.04 23 /32 23 /32 1/20.08 7 /8 7 /8 1/2 x 3/80.06 13 /16 13 /16 1/2 x 1/40.03 25 /32 21 /32 5/80.101 3 /32 1 3 /32 5/8 x 1/20.091 1 /16 1 1 /16 3/40.161 1 /8 1 1 /8 3/4 x 5/80.131 1 /4 1 3 /32 3/4 x 1/20.101 1 /8 1 1 /16 7/80.281 19 /32 1 19 /32 10.281 7 /16 1 7 /16 1 x 3/40.201 1 /4 1 1 /8 1 x 5/80.151 13 /32 1 3 /32 1 1/40.421 7 /8 1 7 /8 1 1/4 x 10.331 25 /32 1 1 /2 1 1/20.662 1 /4 2 1 /4 21.232 15 /16 2 15 /16 2 1/21.963 11 /16 3 11 /16 32.934 1 /32 4 1 /32 45.955 1 /4 5 1 /4 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 13 Consult price sheet for Made to Order items and for minimum order quantities.607-2 90°Fitting Elbow–Close Rough Ftg x C – Wrot APPROX.DIM. BDIM. C NOM. SIZENET WT./LBS.INCHESINCHES 1/40.02 3 /4 3 /8 3/80.03 15 /16 1 /2 1/20.04 31 /32 3 /8 5/80.071 7 /32 17 /32 3/40.101 11 /32 17 /32 10.201 3 /4 27 /32 1 1/40.332 1 /8 1 1 /32 1 1/20.462 13 /32 1 7 /32 20.842 27 /32 1 1 /2 2 1/21.393 15 /32 1 29 /32 32.103 13 /16 2 3 /32 44.004 3 /4 2 25 /32 607-2-I 90°Fitting Elbow – Intermediate Radius Ftg x C – Wrot APPROX.DIM. BDIM. C NOM. SIZENET WT./LBS.INCHESINCHES 1/20.061 5 /32 19 /32 5/80.091 9 /16 7 /8 3/40.141 5 /8 13 /16 10.242 1 /32 1 1 /16 607-2-LT 90°Fitting Elbow – Long Radius Ftg x C – Wrot APPROX.DIM. BDIM. C NOM. SIZENET WT./LBS.INCHESINCHES 1/80.01 13 /32 1 /2 1/40.021 1 /8 3 /4 3/80.051 1 /8 7 /8 1/20.081 9 /16 1 3 /32 1/2 x 3/80.061 5 /16 13 /16 1/2 x 1/40.031 1 /4 5 /8 5/80.101 25 /32 1 3 /32 3/40.161 15 /16 1 1 /8 10.312 1 /2 1 21 /32 1 1/40.432 29 /32 1 7 /8 1 1/20.662 13 /32 2 1 /4 1 1/2 x 1 1/40.503 3 /8 2 3 /32 21.274 11 /32 2 31 /32 2 1/22.165 7 /32 3 11 /16 33.105 3 /4 4 1 /32 607-2-2 90°Fitting Elbow–Close Rough Ftg x Ftg – Wrot APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1/20.041 1 /16 3/40.121 15 /32 10.201 23 /32 1 1/40.332 1 /8 1 1/20.462 13 /32 20.822 27 /32 32.123 7 /8 ELBOWS continued 607-2-2-LT 90°Fitting Elbow – Long Radius Ftg x Ftg – Wrot APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1/40.02 27 /32 3/80.041 1 /8 1/20.081 19 /32 5/80.101 11 /16 3/40.161 15 /16 10.312 1 /2 1 1/40.432 29 /32 1 1/20.653 7 /16 21.254 11 /32 707-2-4 90°Fitting Elbow Ftg x M – Cast APPROX.DIM. BDIM. E NOM. SIZENET WT./LBS.INCHESINCHES 1/20.12 7 /8 25 /32 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 14 ELBOWS continued Consult price sheet for Made to Order items and for minimum order quantities.707-3 90°Elbow C x F – Cast APPROX.DIM. CDIM. E NOM. SIZENET WT./LBS.INCHESINCHES 1/40.06 13 /32 9 /16 3/80.09 7 /16 11 /16 3/8 x 1/20.13 9 /16 13 /16 1/20.12 7 /16 13 /16 1/2 x 3/40.18 11 /16 15 /16 1/2 x 3/80.09 1 /2 13 /16 1/2 x 1/40.10 3 /8 23 /32 3/40.18 21 /32 15 /16 3/4 x 10.35 13 /16 1 1 /8 3/4 x 1/20.20 9 /16 15 /16 10.43 25 /32 1 1 /4 1 x 3/40.35 11 /16 1 3 /16 1 x 1/20.26 9 /16 1 1 /8 1 1/40.6711 1 /2 1 1/4 x 3/40.47 9 /16 1 11 /16 1 1/20.891 1 /8 1 5 /8 21.461 3 /8 1 15 /16 707-3-5 90°Drop Elbow C x F – Cast NOM. APPROX.DIM. ADIM. CDIM. E SIZENET WT./LBS.INCHESINCHESINCHES 3/80.12 11 /32 7 /16 11 /16 3/8 x 1/20.18 11 /32 9 /16 13 /16 1/20.15 13 /32 9 /16 7 /8 1/2 x 3/80.17 3 /8 1 /2 13 /16 3/40.28 17 /32 21 /32 15 /16 3/4 x 1/20.24 17 /32 9 /16 15 /16 10.49 5 /8 25 /32 1 1 /4 707-3-5-A 90°Hy-Set Elbow C x F – Cast APPROX.DIM. CDIM. E NOM. SIZENET WT./LBS.INCHESINCHES 1/20.21 9 /16 7 /8 707-3-6 90°Union Elbow C x F – Cast APPROX.DIM. ADIM. E NOM. SIZENET WT./LBS.INCHESINCHES 1/20.311 1 /8 7 /8 3/40.491 7 /16 1 10.791 7 /8 1 1 /4 707-4 90°Elbow C x M – Cast APPROX.DIM. CDIM. E NOM. SIZENET WT./LBS.INCHESINCHES 3/80.08 5 /16 7 /8 1/20.12 7 /16 1 5 /32 1/2 x 3/40.18 9 /16 1 5 /32 1/2 x 3/80.10 5 /16 15 /16 3/40.21 9 /16 1 11 /32 3/4 x 10.33 21 /32 1 13 /32 3/4 x 1/20.18 7 /16 1 7 /32 10.43 23 /32 1 5 /8 1 1/40.58 7 /8 1 11 /16 1 1/20.8111 31 /32 21.381 1 /4 2 9 /32 707-4-6 90°Union Elbow C x M – Cast APPROX.DIM. ADIM. E NOM. SIZENET WT./LBS.INCHESINCHES 3/80.211 3 /32 1 3 /16 1/20.301 1 /32 1 1 /2 3/40.491 5 /16 1 13 /16 10.721 23 /32 1 5 /8 1 1/41.161 3 /4 1 27 /32 707-5 90°Drop Elbow C x C – Cast APPROX.DIM. ADIM. C NOM. SIZENET WT./LBS.INCHESINCHES 1/20.13 13 /32 7 /16 3/40.24 17 /32 9 /16 707-5-A 90°Hy-Set Elbow C x C – Cast NOM. APPROX.DIM. ADIM. CDIM. D SIZENET WT./LBS.INCHESINCHESINCHES 1/20.13 31 /32 7 /16 15 /32 3/40.211 5 /16 9 /16 9 /16 707-6 90°Union Elbow C x C – Cast APPROX.DIM. ADIM. C NOM. SIZENET WT./LBS.INCHESINCHES 3/80.17 31 /32 5 /16 1/20.241 7 /16 3/40.391 17 /32 9 /16 10.641 21 /32 23 /32 1 1/41.071 19 /32 23 /32 708 90°Flanged Sink Elbow C x F – Cast NOM. APPROX.DIM. ADIM. CDIM. F SIZENET WT./LBS.INCHESINCHESINCHES 1/20.20 7 /8 9 /16 1 3 /4 764 90°Double Elbow C x C x C – Cast APPROX.DIM. CDIM. D NOM. SIZENET WT./LBS.INCHESINCHES 1 x 3/4 x 3/40.33 3 /4 21 /32 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 15 ELBOWS continued Consult price sheet for Made to Order items and for minimum order quantities.FITTING REDUCERS APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 4 x 3 1/22.092 5 /8 4 x 32.003 1 /32 4 x 2 1/21.563 1 /32 4 x 21.763 13 /32 5 x 43.303 9 /16 5 x 32.974 1 /16 5 x 2 1/23.304 11 /32 5 x 22.884 11 /16 6 x 55.564 3 /16 6 x 45.094 9 /16 6 x 34.675 1 /16 6 x 2 1/24.475 11 /32 6 x 24.515 19 /32 8 x 612.335 15 /32 8 x 510.355 15 /16 8 x 411.106 7 /16 8 x 310.636 15 /16 8 x 2 1/211.417 3 /16 8 x 210.867 7 /16 741 Companion Flange C – Cast NOM. APPROX.DIM. BDIM. FDIM. GDIM. W SIZENET WT./LBS.INCHESINCHESINCHESINCHES 1/20.55 1 /8 3 1 /2 3 /16 2 3 /8 3/40.71 1 /8 3 7 /8 3 /16 2 3 /4 11.26 1 /8 4 1 /4 1 /4 3 1 /8 1 1/41.42 1 /8 4 5 /8 1 /4 3 1 /2 1 1/21.82 1 /8 5 5 /16 3 7 /8 22.76 1 /8 6 3 /8 4 3 /4 2 1/24.29 1 /8 7 3 /8 5 1 /2 35.26 1 /8 7 1 /2 7 /16 6 47.60 1 /8 9 7 /16 7 1 /2 59.04 1 /8 10 7 /16 8 1 /2 612.68 1 /8 11 1 /2 9 1 /2 NOTE:Dim. B = Tube Stop to Flange Face 600-2 Fitting Reducer Ftg x C – Wrot APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1/4 x 1/80.01 15 /32 3/8 x 1/40.01 19 /32 3/8 x 1/80.01 25 /32 1/2 x 3/80.03 11 /16 1/2 x 1/40.02 25 /32 5/8 x 1/20.04 7 /8 5/8 x 3/80.04 31 /32 5/8 x 1/40.031 1 /32 3/4 x 5/80.06 31 /32 3/4 x 1/20.061 1 /8 3/4 x 3/80.051 1 /8 3/4 x 1/40.051 3 /32 1 x 3/40.101 7 /32 1 x 5/80.091 3 /8 1 x 1/20.091 1 /4 1 x 3/80.081 9 /32 1 1/4 x 10.151 5 /16 1 1/4 x 3/40.161 1 /2 1 1/4 x 1/20.131 3 /8 1 1/2 x 1 1/40.231 13 /32 1 1/2 x 10.211 5 /8 1 1/2 x 3/40.201 7 /8 1 1/2 x 1/20.161 19 /32 2 x 1 1/20.401 31 /32 2 x 1 1/40.342 3 /32 2 x 10.351 27 /32 2 x 3/40.351 27 /32 2 x 1/20.341 31 /32 2 1/2 x 20.651 31 /32 2 1/2 x 1 1/20.652 3 /8 2 1/2 x 1 1/40.602 7 /32 2 1/2 x 10.782 9 /32 3 x 2 1/21.032 1 /4 3 x 20.992 9 /16 3 x 1 1/20.812 19 /32 3 x 1 1/41.293 1 /4 3 1/2 x 31.482 11 /32 Continues…FLANGES – CLASS 125 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 16 Consult price sheet for Made to Order items and for minimum order quantities.FLANGES – CLASS 150 771 Companion Flange C – Cast NOM. APPROX.DIM. BDIM. FDIM. GDIM. W SIZENET WT./LBS.INCHESINCHESINCHESINCHES 3/41.15 1 /8 3 7 /8 11 /32 2 3 /4 11.59 1 /8 4 1 /4 3 /8 3 1 /8 1 1/41.91 1 /8 4 5 /8 13 /32 3 1 /2 1 1/22.59 1 /8 5 7 /16 3 7 /8 24.10 1 /8 6 1 /2 4 3 /4 2 1/26.22 1 /8 7 9 /16 5 1 /2 38.03 1 /8 7 1 /2 5 /8 6 411.85 1 /8 9 11 /16 7 1 /2 515.69 1 /8 10 3 /4 8 1 /2 620.32 1 /8 11 13 /16 9 1 /2 NOTE:Dim. B = Tube Stop to Flange Face 775 Threaded Companion Flange F – Cast NOM. APPROX.DIM. EDIM. FDIM. W SIZENET WT./LBS.INCHESINCHES INCHES 24.31164 3 /4 2 1/26.301 1 /8 75 1 /2 37.131 3 /16 7 1 /2 6 410.201 5 /16 97 1 /2 PLUGS 616 Fitted Plug Ftg - Wrot APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 3/80.016 1 /16 1/20.02 3 /32 3/4 0.24 1 /8 638 Return Bend C x C – Wrot APPROX.DIM. EDIM. J NOM. SIZENET WT./LBS.INCHESINCHES 1/80.02 21 /32 1 1/40.04 21 /32 1 1 /2 3/80.081 1 /32 1 1 /2 1/20.131 1 /2 2 3/40.261 19 /32 2 1 /2 10.442 3 /32 3 1 1/40.702 3 /4 4 1 1/21.043 5 /32 4 1 /2 21.923 29 /32 5 1 /2 739 Return Bend – Closed C x C – Cast APPROX.DIM. EDIM. J NOM. SIZENET WT./LBS.INCHESINCHES 3/40.291 5 /32 1 5 /16 RETURN BENDS STRAPS TEES 623 Copper Hanger Strap APPROX.SIZENET WT./LBS.3/4" Wide x 25 Ft. Roll1.93 624 Tube Strap APPROX.NOM. SIZENET WT./LBS.1/80.01 1/40.01 3/80.01 1/20.01 5/80.02 3/40.02 10.02 1 1/40.03 1 1/20.03 20.04 705 Baseboard Tee C x F x C – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CDE 1/2 x1/8x 3/40.15 7 /16 9 /16 11 /16 1/2x1/8x1/20.11 7 /16 7 /16 9 /16 3/4x1/8x10.29 5 /8 3 /4 13 /16 3/4x1/8x3/40.19 9 /16 9 /16 11 /16 1 x 1/8 x 10.32 23 /32 23 /32 3 /4 11/4x1/8x11/40.51 7 /8 7 /8 15 /16 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 17 Consult price sheet for Made to Order items and for minimum order quantities.TEES continued 705-D Vent Elbow C x C – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CDS 1/20.10 7 /16 7 /16 25 /32 3/40.20 9 /16 9 /16 29 /32 10.31 23 /32 23 /32 1 1 /32 710-3 Tee F x F x C – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CES 1/20.20 9 /16 7 /8 7 /8 3/40.37 11 /16 11 3/4x 3/4 x 1/20.31 11 /16 31 /32 31 /32 3/4x 1/2 x 3/40.29 11 /16 1 15 /16 3/4x 1/2 x 1/20.27 11 /16 31 /32 7 /8 710-3-4 Tee M x F x C – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CES 3/40.34 11 /16 1 11 /32 1 3/4x 3/4 x 1/20.33 11 /16 1 7 /32 31 /32 611 Tee C x C x C – Wrot APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CFG 3/16 O.D.0.01 7 /32 7 /32 7 /32 1/80.02 1 /4 1 /4 7 /32 1/8 x 1/8 x 1/40.02 13 /32 13 /32 1 /4 1/8 x 1/8 x 3/16 O.D.0.01 1 /4 1 /4 5 /16 1/8 x 3/16 O.D. x 1/80.01 1 /4 11 /32 7 /32 5/16 O.D. 0.02 3 /8 3 /8 5 /16 5/16 O.D. x 5/16 O.D. x 1/40.02 3 /8 3 /8 1 /4 5/16 O.D. x 5/16 O.D. x 1/80.02 3 /8 3 /8 13 /32 5/16 O.D. x 1/8 x 5/16 O.D. 0.02 3 /8 13 /32 5 /16 5/16 O.D. x 1/8 x 1/80.02 3 /8 13 /32 13 /32 1/40.02 5 /16 5 /16 1 /4 1/4 x 1/4 x 1/20.06 19 /32 19 /32 3 /8 1/4 x 1/4 x 3/80.04 17 /32 17 /32 11 /32 1/4 x 1/4 x 5/16 O.D.0.02 5 /16 5 /16 5 /16 1/4 x 1/4 x 1/80.02 5 /16 5 /16 13 /32 1/4 x 1/4 x 3/16 O.D.0.02 5 /16 5 /16 7 /16 1/4 x 5/16 O.D. x 1/40.02 5 /16 3 /8 1 /4 1/4 x 1/8 x 1/40.02 5 /16 13 /32 1 /4 1/4 x 1/8 x 1/80.02 5 /16 13 /32 3 /8 3/80.04 11 /32 11 /32 11 /32 3/8 x 3/8 x 1/20.07 17 /32 17 /32 3 /8 3/8 x 3/8 x 1/40.04 11 /32 11 /32 15 /32 3/8 x 3/8 x 5/16 O.D.0.04 11 /32 11 /32 11 /32 3/8 x 3/8 x 1/80.04 11 /32 11 /32 11 /32 3/8 x 1/4 x 3/80.04 11 /32 17 /32 11 /32 3/8 x 1/4 x 1/40.04 11 /32 17 /32 15 /32 3/8 x 1/4 x 1/80.04 11 /32 17 /32 9 /16 3/8 x 1/8 x 3/80.04 11 /32 19 /32 11 /32 3/8 x 1/8 x 1/80.04 11 /32 19 /32 19 /32 1/20.06 11 /32 11 /32 11 /32 1/2 x 1/2 x 10.2911 21 /32 1/2 x 1/2 x 3/40.12 17 /32 17 /32 11 /32 1/2 x 1/2 x 5/80.11 5 /8 5 /8 7 /16 1/2 x 1/2 x 3/80.07 5 /16 5 /16 13 /32 1/2 x 1/2 x 1/40.06 5 /16 5 /16 9 /16 1/2 x 3/8 x 1/20.07 7 /16 17 /32 3 /8 1/2 x 3/8 x 3/80.06 5 /16 17 /32 13 /32 1/2 x 3/8 x 1/40.06 5 /16 17 /32 17 /32 1/2 x 1/4 x 3/80.06 5 /16 5 /8 9 /16 Continues…APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CFG 5/80.12 7 /16 7 /16 7 /16 5/8 x 5/8 x 3/40.15 23 /32 23 /32 1 /2 5/8 x 5/8 x 1/20.11 7 /16 7 /16 13 /32 5/8 x 5/8 x 3/80.09 7 /16 7 /16 5 /8 5/8 x 5/8 x 1/40.09 7 /16 7 /16 3 /4 5/8 x 1/2 x 5/80.10 7 /16 5 /8 7 /16 5/8 x 1/2 x 1/20.09 7 /16 19 /32 13 /32 5/8 x 3/8 x 5/80.10 7 /16 3 /4 7 /16 5/8 x 3/8 x 3/80.09 7 /16 3 /4 5 /8 3/40.15 1 /2 1 /2 1 /2 3/4 x 3/4 x 10.22 23 /32 23 /32 1 /2 3/4 x 3/4 x 5/80.16 17 /32 17 /32 11 /16 3/4 x 3/4 x 1/20.12 7 /16 7 /16 17 /32 3/4 x 3/4 x 3/80.12 7 /16 7 /16 21 /32 3/4 x 3/4 x 1/40.12 13 /32 13 /32 23 /32 3/4 x 3/4 x 1/80.12 7 /16 7 /16 13 /16 3/4 x 5/8 x 3/40.15 17 /32 11 /16 1 /2 3/4 x 5/8 x 5/80.15 17 /32 23 /32 11 /16 3/4 x 1/2 x 3/40.15 17 /32 25 /32 1 /2 3/4 x 1/2 x 1/20.12 13 /32 19 /32 1 /2 3/4 x 1/2 x 3/80.12 7 /16 21 /32 21 /32 3/4 x 3/8 x 3/40.15 17 /32 17 /32 1 /2 3/4 x 3/8 x 1/20.12 7 /16 23 /32 17 /32 3/4 x 3/8 x 3/80.12 7 /16 23 /32 21 /32 7/80.31 23 /32 23 /32 23 /32 10.30 11 /16 11 /16 21 /32 1 x 1 x 1 1/20.601 11 /32 1 11 /32 31 /32 1 x 1 x 1 1/40.4211 29 /32 1 x 1 x 3/40.27 9 /16 9 /16 21 /32 1 x 1 x 5/80.26 9 /16 9 /16 7 /8 1 x 1 x 1/20.23 15 /32 15 /32 23 /32 1 x 1 x 3/80.23 15 /32 15 /32 29 /32 1 x 1 x 1/40.23 15 /32 15 /32 1 1 x 3/4 x 10.29 11 /16 7 /8 21 /32 1 x 3/4 x 3/40.26 9 /16 23 /32 3 /4 1 x 3/4 x 1/20.22 15 /32 21 /32 23 /32 Continues…NOTE: Tee sizes are readRun x Run x Outlet. APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CFG 1 x 1/2 x 10.29 11 /16 1 21 /32 1 x 1/2 x 3/40.27 9 /16 13 /16 3 /4 1 x 1/2 x 1/20.22 15 /32 25 /32 23 /32 1 1/40.43 13 /16 3 /16 13 /16 1 1/4 x 1 1/4 x 21.131 30 /32 1 30 /32 1 3 /32 1 1/4 x 1 1/4 x 1 1/20.601 3 /16 1 3 /16 29 /32 1 1/4 x 1 1/4 x 10.45 25 /32 25 /32 29 /32 1 1/4 x 1 1/4 x 3/40.37 21 /32 21 /32 3 /4 1 1/4 x 1 1/4 x 1/20.30 1 /2 1 /2 25 /32 1 1/4 x 1 1/4 x 3/80.34 23 /32 23 /32 29 /32 1 1/4 x 1 x 1 1/40.43 13 /16 1 1 /32 13 /16 1 1/4 x 1 x 10.47 25 /32 7 /8 29 /32 1 1/4 x 1 x 3/40.35 21 /32 25 /32 7 /8 1 1/4 x 1 x 1/20.30 1 /2 5 /8 29 /32 1 1/4 x 3/4 x 1 1/40.42 13 /16 1 1 /8 13 /16 1 1/4 x 3/4 x 10.45 25 /32 1 1 /32 29 /32 1 1/4 x 3/4 x 3/40.37 21 /32 15 /16 7 /8 1 1/4 x 3/4 x 1/20.30 1 /2 3 /4 29 /32 1 1/4 x 1/2 x 1 1/40.41 13 /16 1 7 /32 13 /16 1 1/20.61 31 /32 31 /32 29 /32 1 1/2 x 1 1/2 x 21.111 25 /32 1 25 /32 1 3 /32 1 1/2 x 1 1/2 x 1 1/40.62 29 /32 29 /32 1 1 /16 1 1/2 x 1 1/2 x 10.55 11 /16 11 /16 7 /8 1 1/2 x 1 1/2 x 3/40.45 11 /16 11 /16 1 1 /32 1 1/2 x 1 1/2 x 1/20.40 1 /2 1 /2 1 1 /32 1 1/2 x 1 1/4 x 1 1/20.621 1 /32 1 3 /16 29 /32 1 1/2 x 1 1/4 x 1 1/40.62 31 /32 1 3 /32 31 /32 1 1/2 x 1 1/4 x 10.51 25 /32 11 1 /32 1 1/2 x 1 1/4 x 3/40.49 11 /16 13 /16 1 1 /32 1 1/2 x 1 1/4 x 1/20.41 1 /2 25 /32 1 1 /32 1 1/2 x 1 x 1 1/20.591 1 /32 1 11 /32 29 /32 1 1/2 x 1 x 1 1/40.63 29 /32 1 1 /8 1 1 /16 1 1/2 x 1 x 10.54 25 /32 1 1 /16 1 1 /32 1 1/2 x 1 x 3/40.44 11 /16 31 /32 15 /16 1 1/2 x 1 x 1/20.39 1 /2 25 /32 1 1 /32 1 1/2 x 3/4 x 1 1/20.621 1 /32 1 7 /16 1 1 /16 1 1/2 x 3/4 x 1 1/40.58 29 /32 1 11 /32 1 1 /16 1 1/2 x 3/4 x 10.54 25 /32 1 1 /4 1 1 /32 1 1/2 x 3/4 x 3/40.47 11 /16 1 3 /32 29 /32 1 1/2 x 3/4 x 1/20.39 1 /2 29 /32 31 /32 1 1/2 x 1/2 x 1 1/20.621 1 /32 1 13 /32 31 /32 Continues…APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CFG 21.301 9 /32 1 9 /32 1 1 /32 2 x 2 x 2 1/22.34221 21 /32 2 x 2 x 1 1/21.171 1 /4 1 1 /4 1 23 /32 2 x 2 x 1 1/41.12 9 /32 9 /32 1 7 /8 2 x 2 x 10.90 27 /32 27 /32 1 1 /4 2 x 2 x 3/40.88 19 /32 19 /32 1 1 /4 2 x 2 x 1/21.171 1 /4 1 1 /4 2 1 /4 2 x 1 1/2 x 21.161 9 /32 1 7 /8 1 11 /32 2 x 1 1/2 x 1 1/21.151 1 /4 1 3 /4 1 23 /32 2 x 1 1/2 x 1 1/41.15 7 /32 1 3 /4 1 11 /32 2 x 1 1/2 x 3/40.83 21 /32 15 /16 1 7 /32 2 x 1 1/2 x 1/21.121 1 /4 1 25 /32 2 1 /4 2 x 1 1/4 x 21.581 9 /32 1 15 /32 1 9 /32 2 x 1 1/4 x 1 1/21.161 1 /4 1 31 /32 1 23 /32 2 x 1 1/4 x 1 1/41.19 15 /16 1 11 /32 1 11 /32 2 x 1 1/4 x 10.90 27 /32 1 9 /32 1 11 /32 2 x 1 1/4 x 3/40.85 21 /32 11 8 /27 2 x 1 x 21.111 1 /8 1 25 /32 1 1 /4 2 x 1 x 10.89 27 /32 1 9 /32 1 11 /32 2 x 3/4 x 21.151 9 /32 2 3 /16 1 1 /4 2 x 1/2 x 21.151 9 /32 2 3 /8 1 1 /4 2 1/22.401 5 /8 1 5 /8 1 5 /8 2 1/2 x 2 1/2 x 21.971 5 /16 1 5 /16 1 21 /32 2 1/2 x 2 1/2 x 1 1/21.531 3 /32 1 3 /32 1 21 /32 2 1/2 x 2 1/2 x 1 1/41.721 3 /32 1 3 /32 1 27 /32 2 1/2 x 2 1/2 x 11.34 25 /32 25 /32 1 11 /16 2 1/2 x 2 1/2 x 3/41.34 25 /32 25 /32 1 13 /16 2 1/2 x 2 1/2 x 1/21.34 25 /32 25 /32 2 1 /8 2 1/2 x 2 x 2 1/21.991 21 /32 2 3 /32 1 21 /32 2 1/2 x 2 x 21.951 11 /32 1 5 /8 1 23 /32 2 1/2 x 2 x 1 1/21.571 3 /32 2 13 /32 1 21 /32 2 1/2 x 2 x 1 1/41.571 3 /32 1 19 /32 1 27 /32 2 1/2 x 2 x 11.40 25 /32 1 9 /32 1 3 /4 2 1/2 x 2 x 3/41.35 25 /32 1 9 /32 1 27 /32 2 1/2 x 1 1/2 x 1 1/21.761 3 /32 1 13 /32 1 3 /8 2 1/2 x 1 1/4 x 2 1/22.401 21 /32 2 7 /16 1 21 /32 2 1/2 x 1 x 2 1/22.041 21 /32 2 23 /32 1 21 /32 2 1/2 x 3/4 x 2 1/22.001 21 /32 2 11 /16 1 21 /32 2 1/2 x 1/2 x 2 1/22.461 1 /2 2 7 /32 1 1 /2 Continues…APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CFG 33.151 7 /8 1 7 /8 2 1 /32 3 x 3 x 2 1/23.551 29 /32 1 29 /32 2 3 /8 3 x 3 x 23.191 15 /32 1 15 /32 1 31 /32 3 x 3 x 1 1/23.081 15 /32 1 15 /32 2 9 /32 3 x 3 x 1 1/43.101 15 /32 1 15 /32 2 7 /16 3 x 3 x 12.12 27 /32 27 /32 1 31 /32 3 x 3 x 3/42.39 27 /32 27 /32 2 3 /16 3 x 3 x 1/21.82 27 /32 27 /32 2 3 /8 3 x 2 1/2 x 33.081 7 /8 2 3 /8 1 31 /32 3 x 2 1/2 x 2 1/23.121 29 /32 2 11 /32 2 5 /32 3 x 2 1/2 x 22.281 15 /32 1 27 /32 1 31 /32 3 x 2 x 33.621 29 /32 2 17 /32 1 15 /16 3 x 2 x 2 1/23.561 29 /32 2 9 /16 2 5 /16 3 x 2 x 23.221 15 /32 1 31 /32 1 31 /32 3 x 1 1/2 x 33.131 29 /32 2 25 /32 2 3 /32 3 x 1 1/4 x 33.631 29 /32 2 25 /32 1 15 /16 3 x 1 x 33.201 31 /32 2 19 /32 2 3 /16 3 x 3/4 x 33.551 31 /32 2 29 /32 2 3 /16 3 1/25.202 17 /32 2 17 /32 2 17 /32 48.122 13 /32 2 13 /32 2 17 /32 4 x 4 x 36.702 1 /32 2 1 /32 2 21 /32 4 x 4 x 2 1/26.652 1 /32 2 1 /32 3 5 /32 4 x 4 x 25.821 15 /32 1 15 /32 2 7 /16 4 x 4 x 1 1/23.941 11 /32 1 11 /32 2 17 /32 4 x 4 x 1 1/44.041 11 /32 1 11 /32 2 29 /32 4 x 4 x 13.72112 9 /16 4 x 4 x 3/43.70112 11 /16 4 x 3 x 47.052 25 /32 3 7 /32 2 17 /32 4 x 3 x 35.032 1 /32 2 15 /32 2 15 /32 4 x 3 x 2 1/25.042 1 /32 2 15 /32 2 29 /32 4 x 3 x 25.871 15 /32 1 31 /32 2 7 /16 4 x 2 1/2 x 47.192 25 /32 3 15 /32 2 27 /32 4 x 2 x 47.082 25 /32 3 19 /32 2 27 /32 Continued on next page.NOTE: Tee sizes are readRun x Run x Outlet.611 Tee C x C x C – Wrot continued AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 18 TEES continued Consult price sheet for Made to Order items and for minimum order quantities. 611-HE Heat Exchanger Tee C x C x C – Wrot Tube slips entirely through fitting on small end of run. Sizes same as listed under 611 where tee has one or more reductions on one end of run.711 Tee C x C x C – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CFG 1 1/4 x 1/2 x 10.48 3 /4 3 /4 7 /8 1 1/4 x 1/2 x 1/20.50 9 /16 5 /8 1 1 1/2 x 1/2 x 1 1/40.70 7 /8 31 /32 1 2 x 2 x 33.111 21 /32 1 21 /32 1 5 /16 2 x 1 x 1 1/21.2311 1 /4 1 1 /4 2 x 3/4 x 3/40.84 21 /32 7 /8 1 1 /4 2 1/2 x 2 1/2 x 32.981 3 /4 1 3 /4 1 17 /32 2 1/2 x 1 1/2 x 22.021 1 /4 1 15 /32 1 1 /2 2 1/2 x 1 1/2 x 1 1/21.761 3 /32 1 13 /32 1 3 /8 2 1/2 x 1/2 x 2 1/22.461 1 /2 2 7 /32 1 1 /2 3 x 3 x 46.962 11 /32 2 11 /32 1 23 /32 3 x 2 1/2 x 1 1/22.5311 3 /32 1 3 /4 3 x 2 x 1 1/22.6211 1 /4 1 3 /4 4 x 4 x 616.473 7 /32 3 7 /32 2 9 /32 4 x 2 x 24.641 1 /4 1 3 /4 2 1 /4 711-A Supply and Return Tee C x C x C – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CJ 1/20.17 13 /16 1 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 19 TEES continued Consult price sheet for Made to Order items and for minimum order quantities.611 Tee C x C x C – Wrot continued APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CFG 58.292 27 /32 2 27 /32 3 13 /32 5 x 5 x 47.092 7 /32 2 9 /32 3 3 /16 5 x 5 x 35.911 25 /32 1 25 /32 3 3 /16 5 x 5 x 2 1/25.901 5 /16 1 5 /16 3 3 /16 5 x 5 x 25.291 1 /16 1 1 /16 3 3 /16 5 x 5 x 1 1/24.871 1 /32 1 1 /32 3 3 /16 5 x 5 x 1 1/44.50 11 /16 11 /16 3 3 /16 5 x 5 x 14.20 9 /16 9 /16 3 3 /16 5 x 4 x 58.532 27 /32 4 29 /32 3 13 /32 5 x 4 x 48.172 1 /4 4 17 /32 3 3 /8 5 x 2 x 59.472 3 /4 5 1 /16 3 1 /2 613.503 9 /32 3 9 /32 4 1 /32 6 x 6 x 511.672 25 /32 2 25 /32 4 1 /32 6 x 6 x 410.172 9 /32 2 9 /32 3 11 /16 6 x 6 x 38.921 25 /32 1 25 /32 3 11 /16 6 x 6 x 2 1/28.111 17 /32 1 17 /32 3 3 /4 6 x 6 x 27.781 9 /32 1 9 /32 3 11 /16 6 x 6 x 1 1/26.86113 11 /16 6 x 6 x 1 1/46.66 29 /32 29 /32 3 11 /16 6 x 6 x 17.19 9 /16 9 /16 3 11 /16 6 x 6 x 3/47.18 9 /16 9 /16 4 9 /16 6 x 6 x 1/27.17 9 /16 9 /16 4 11 /16 6 x 4 x 616.603 3 /16 5 1 /8 4 1 /8 6 x 4 x 1 1/29.62 15 /16 2 15 /16 3 3 /4 836.814 1 /16 4 1 /16 5 1 /32 8 x 8 x 627.863 1 /16 3 1 /16 5 1 /8 8 x 8 x 524.902 25 /32 2 25 /32 4 15 /16 8 x 8 x 422.262 1 /16 2 1 /16 4 3 /4 8 x 8 x 320.011 9 /16 1 9 /16 4 3 /4 8 x 8 x 2 1/219.021 5 /16 1 5 /16 4 3 /4 8 x 8 x 218.011 1 /16 1 1 /16 4 3 /4 NOTE: Tee sizes are readRun x Run x Outlet.611-2 Fitting Tee C x Ftg x C – Wrot APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.BCF 1/20.071 1 /32 3 /8 7 /16 3/40.151 15 /32 1 /2 17 /32 711-5 Drop Tee C x C x C – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.AC 1/20.16 3 /8 7 /16 712 Tee C x C x F – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.EFG 3/80.11 11 /16 7 /16 7 /16 1/20.14 13 /16 7 /16 7 /16 3/40.331 21 /32 21 /32 10.541 1 /4 7 /8 7 /8 1 1/21.081 5 /8 1 1 /8 1 1 /8 21.741 7 /8 1 3 /8 1 3 /8 1/2 x 1/2 x 1/40.16 13 /16 1 /2 1 /2 1/2 x 1/2 x 3/80.15 13 /16 1 /2 1 /2 1/2 x 1/2 x 3/40.23 15 /16 11 /16 11 /16 3/4 x 3/4 x 3/80.23 7 /8 1 /2 1 /2 3/4 x 3/4 x 1/20.24 57 /64 17 /32 17 /32 1 1/4 x 1 1/4 x 1/20.491 1 /4 9 /16 9 /16 1 1/4 x 1 1/4 x 3/40.551 5 /16 11 /16 11 /16 1 1/4 x 1 1/4 x 10.661 7 /16 7 /8 7 /8 1 x 1 x 1/20.341 1 /8 9 /16 9 /16 1 x 1 x 3/40.421 3 /16 11 /16 11 /16 1 1/2 x 1 1/2 x 1/20.621 3 /8 9 /16 9 /16 1 1/2 x 1 1/2 x 3/40.701 7 /16 11 /16 11 /16 1 1/2 x 1 1/2 x 10.791 1 /2 13 /16 13 /16 2 x 2 x 1/20.971 5 /8 17 /32 17 /32 2 x 2 x 3/41.101 11 /16 11 /16 11 /16 2 x 2 x 11.231 3 /4 13 /16 13 /16 1/40.08 13 /16 9 /32 9 /32 1 1/40.761 7 /16 11 3/8 x 3/8 x 1/40.12 11 /16 7 /16 7 /16 3/4 x 1/2 x 3/40.281 21 /32 11 /16 3/4 x 3/4 x 10.401 1 /8 7 /8 7 /8 712-5 Drop Tee C x C x F – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.ACE 1/20.25 3 /8 9 /16 7 /8 3/40.38 1 /2 21 /32 1 713 Tee C x C x M – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.EF 1/20.151 3 /32 7 /16 3/40.291 9 /32 9 /16 714 Tee C x F x C – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CES 1/20.18 7 /16 9 /16 7 /8 1/2 x 3/4 x 1/20.27 7 /16 9 /16 1 3 /16 3/40.31 9 /16 11 /16 1 3/4 x 1/2 x 3/40.26 9 /16 9 /16 15 /16 10.52 23 /32 13 /16 1 1 /4 1 x 3/4 x 10.43 23 /32 23 /32 1 3 /16 1 x 1/2 x 10.42 3 /4 3 /4 1 1 /8 1 1/40.70 7 /8 11 13 /32 1 1/4 x 3/4 x 1 1/40.62 7 /8 7 /8 1 7 /32 1 1/4 x 1/2 x 1 1/40.56 7 /8 7 /8 1 3 /16 1 1/21.0011 1 /8 1 9 /16 1 1/2 x 3/4 x 1 1/20.88111 13 /16 21.721 1 /4 1 3 /8 1 7 /8 2 x 3/4 x 21.571 1 /4 1 1 /4 2 2 x 1/2 x 21.581 1 /4 1 1 /4 2 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 20 TEES continued Consult price sheet for Made to Order items and for minimum order quantities.TRAPS 698 Suction Line P-Trap C x C – Wrot A major application of this fitting is on the suction line of a refregeration compressor. The line is looped, by use of the Suction Line P-Trap, to the floor prior to being run vertically upwards to prevent the drainage of oil back to the compressor during shut down periods. Additional P-Traps are used for each 20' or riser pipe. this prevents high velocity build-up as the oil or liquid begins to return to the compressor during this shut down period.APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CDJK 1/20.365 3 /8 336 5/80.455 3 /8 2 7 /8 36 3/40.585 3 /8 2 3 /4 36 10.925 1 /4 2 21 /32 36 1 1/41.165 3 /8 2 7 /8 3 3 /4 6 1 /8 1 1/22.327 5 /8 3 5 /8 59 23.9383 5 /8 69 7 /16 621 Venturi Insert – Wrot Converts any tee into a special purpose venturi or scoop tee APPROX.NOM. SIZENET WT./LBS.1/20.01 3/40.02 10.03 1 1/40.04 748 90° YC x C x C – Cast APPROX.DIM. ADIM. B NOM. SIZENET WT./LBS.INCHESINCHES 1/20.11 7 /32 7 /16 3/40.25 7 /16 5 /8 10.61 1 /2 13 /16 749 45°YC x C x C – Cast APPROX.DIM. ADIM. B NOM. SIZENET WT./LBS.INCHESINCHES 1/20.151 3 /32 7 /8 3/40.301 17 /32 1 7 /32 10.551 13 /16 1 15 /32 1 1/40.812 1 /4 1 7 /8 1 1/21.142 5 /8 2 1 /8 22.173 5 /16 2 3 /4 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 21 Consult price sheet for Made to Order items and for minimum order quantities.UNIONS 733-2 Fitting Union Ftg x C – Cast APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1/20.231 9 /32 3/40.351 5 /8 10.551 27 /32 733-3 Fitting Union C x F – Cast APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/40.141 5 /32 3/80.191 3 /32 1/20.261 1 /8 3/40.371 5 /16 10.611 7 /16 1 1/40.981 19 /32 1 1/21.211 13 /16 21.902 5 /32 733-4 Union C x M – Cast APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/40.131 1 /2 3/80.201 5 /8 1/20.281 11 /16 1/2 x 3/40.352 1 /16 3/40.431 29 /32 10.682 1 /8 1 1/40.952 5 /32 1 1/21.352 13 /32 22.172 25 /32 2 1/24.133 13 /32 633-W Union C x C – Wrot APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/80.10 5 /8 1/40.15 11 /16 3/80.22 7 /16 1/20.31 13 /32 3/40.33 3 /8 10.54 1 /2 733 Union C x C – Cast APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/40.10 11 /16 3/80.15 7 /16 1/20.22 13 /32 5/80.31 21 /32 3/40.31 3 /8 10.54 1 /2 1 1/40.76 1 /2 1 1/21.04 23 /32 21.77 1 /2 2 1/23.251 34.751 5 /32 VENTURI Y’s Cast Copper Alloy Flared Fittings 100 Series – Heavy Flared 500 Series – Flared Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 Nuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 Tees . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 22 The manufacturing plants at South Glens Falls, NY, Stuarts Draft, VA, Nacogdoches, TX and Reynosa, Mexico manufacture products under a Quality Management System conforming to the current revision of ISO-9001 International Standards AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 23 104 Heavy Flared Adapter FL x M – Cast APPROX.DIM. L NOM. SIZENET WT./LBS.INCHES 3/4 0.602 1 /2 11.243 1 /4 503 Flared Adapter FL x F – Cast APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1/20.361 7 /8 3/40.482 1 /32 11.032 3 /4 1 1/21.993 7 /32 23.223 9 /16 504 Flared Adapter FL x M – Cast APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1/20.291 32 /32 3/40.582 11 /16 10.883 3 /16 1 1/21.893 3 /4 22.954 15 /16 101 Heavy Flared Coupling FL x FL – Cast APPROX.DIM. L NOM. SIZENET WT./LBS.INCHES 3/40.983 13 /16 11.705 5 /16 501 Flared Coupling FL x FL – Cast APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1/2 0.452 3 /8 3/4 0.602 1 /2 11.243 1 /4 1 1/4 2.183 1 /2 1 1/22.653 23 /32 24.034 1 /4 ADAPTERS COUPLINGS Consult price sheet for Made to Order items and for minimum order quantities.507 Flared 90°Elbow FL x FL – Cast APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1/20.541 5 /8 3/40.771 31 /32 11.602 9 /16 25.393 7 /8 507-3 Flared 90°Elbow FL x F – Cast APPROX.DIM. BDIM. E NOM. SIZENET WT./LBS.INCHESINCHES 1/20.491 5 /8 1 1 /2 3/40.691 15 /16 1 5 /8 11.432 9 /16 2 1 /4 507-4 Flared 90°Elbow FL x M – Cast APPROX.DIM. BDIM. E NOM. SIZENET WT./LBS.INCHESINCHES 1/20.341 11 /16 1 13 /32 3/40.551 31 /32 1 19 /32 11.342 3 /32 2 1 1/22.803 5 /16 2 1 /2 ELBOWS 500 Tube Nut – Cast APPROX.DIM. BDIM. L NOM. SIZENET WT./LBS.INCHESINCHES 3/40.201 1 /16 1 1 /2 10.311 3 /8 1 7 /8 TEES 511 Flared Tee FL x FL x FL – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.BDK 1/20.671 5 /8 1 5 /8 1 5 /8 3/41.09222 12.082 5 /8 2 5 /8 2 5 /8 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 24 NUTS Consult price sheet for Made to Order items and for minimum order quantities. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 25 Copper Insert Fittings for Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Brass Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Crimp Rings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Crimp Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Fitting Reducers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Tees . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Tube Cutter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 The manufacturing plants at South Glens Falls, NY, Stuarts Draft, VA, Nacogdoches, TX and Reynosa, Mexico manufacture products under a Quality Management System conforming to the current revision of ISO-9001 International Standards PEX600-2 Fitting ReducerFtgxPEX–Wrot APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/2 0.0351 5 /8 3/40.0591 13 /16 PEX611 TeePEX x PEX x PEX – Wrot APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.ABCD 1/20.0702 1 /4 1 1 /8 1 1 /8 –3/40.0972 1 /2 1 1 /4 1 1 /4 –1/2 x 1/2 x 3/40.1122 3 /4 1 3 /8 1 1 /4 –3/4 x 1/2 x 1/20.0972 1 /2 1 3 /16 11 5 /16 3/4 x 1/2 x 3/40.1122 5 /8 1 1 /4 1 1 /4 1 3 /8 3/4 x 3/4 x 1/20.0992 3 /8 1 3 /16 1–PEX198 Crimp Rings(Black)APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/2 0.0130.325 3/40.0170.325 PEX600-FA Coupling PEX x Swivel FIP – Wrot APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/2 0.0351 1 /2 PEX607 ElbowPEX x PEX – Wrot APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/2 0.0451 1 /4 3/40.0841 7 /16 PEX607-FA Faucet Elbow PEX x Swivel FIP – Wrot APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/2 0.0491 7 /16 PEX707-3-5 Drop Ear Elbow PEX x FIP – Wrot APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/2 0.1872 1 /4 PEX603 AdapterPEX x F – Wrot APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/2 0.1232 9 /16 3/40.2072 3 /4 PEX604 AdapterPEX x M – Wrot APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/2 0.1102 1 /4 3/40.1962 9 /16 PEX600-T AdapterPEX x PB – Wrot APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/2 0.0341 13 /16 3/40.0542 PEX600 CouplingPEX x PEX – Wrot APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1/2 0.0362 3/40.0562 FITTING REDUCERS TEES CRIMP RINGS AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 26 ADAPTERS COUPLINGS ELBOWS Consult price sheet for Made to Order items and for minimum order quantities.COUPLINGS continued PEX841 Crimp Tool APPROX.NOM. SIZENET WT./LBS.3/83.005 1/2 3.005 3/43.005 14.000 PEX100 Tube Cutter APPROX.NOM. SIZENET WT./LBS.—0.03 PEX616 Brass Plugs APPROX.NOM. SIZENET WT./LBS.3/80.0168 1/2 0.0213 3/40.0457 10.0801 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 27 Consult price sheet for Made to Order items and for minimum order quantities.CRIMP TOOL Copper Insert Fittings for Polybutylene Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 Crimp Rings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 Faucet Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 Tees . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 28 The manufacturing plants at South Glens Falls, NY, Stuarts Draft, VA, Nacogdoches, TX and Reynosa, Mexico manufacture products under a Quality Management System conforming to the current revision of ISO-9001 International Standards PB607-FA 90°Elbow Faucet Connector –Barb x Swivel FIPS APPROX.NOM. SIZENET WT./LBS.1/2without nut & washer0.04 PB611 Tee – Barb x Barb x Barb APPROX.NOM. SIZENET WT./LBS.1/20.05 1/2 x 1/2 x 3/40.10 3/40.10 3/4 x 3/4 x 1/20.08 3/4 x 1/2 x 3/40.10 3/4 x 1/2 x 1/20.08 CRIMP RINGS PB198 Crimp Ring – Copper APPROX.NOM. SIZENET WT./LBS.1/20.01 3/40.02 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 29 P B600 Coupling – Barb x Barb APPROX.NOM. SIZENET WT./LBS.1/20.04 3/40.06 PB607 90°Elbow – Barb x Barb APPROX.NOM. SIZENET WT./LBS.1/20.04 3/40.06 PB600-FA Straight Faucet Connector – Barb x Swivel FIPS APPROX.NOM. SIZENET WT./LBS.1/2without nut & washer0.03 COUPLINGS Consult price sheet for Made to Order items and for minimum order quantities.ELBOWS FAUCET CONNECTORS TEES FAUCET CONNECTORS Wrot and Cast DWV Fittings Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31-33 Bushings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 Cleanouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 Closet Flanges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35-36 Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 Return Bends . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 Tees . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 Test Caps & Tees . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37-38 Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39-40 T-Y’s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 Y’s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 30 The manufacturing plants at South Glens Falls, NY, Stuarts Draft, VA, Nacogdoches, TX and Reynosa, Mexico manufacture products under a Quality Management System conforming to the current revision of ISO-9001 International Standards AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 31 903-7 DWV Trap Adapter F x SJ – Wrot APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1 1/4 x 1 1/4 O.D.0.321 7 /16 1 1/2 x 1 1/2 O.D.0.421 7 /16 1 1/2 x 1 1/4 O.D.0.431 19 /32 904-7 DWV Trap Adapter M x SJ – Wrot APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1 1/4 x 1 1/4 O.D.0.411 3 /4 1 1/2 x 1 1/2 O.D.0.511 25 /32 1 1/2 x 1 1/4 O.D.0.491 29 /32 ADAPTERS – SLIP JOINT 801-2-7 DWV Fitting Trap Adapter Ftg x SJ – Cast APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1 1/4 x 1 1/4 O.D.0.251 19 /32 901-2-7 DWV Fitting Trap Adapter Ftg x SJ – Wrot APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1 1/2 x 1 1/2 O.D.0.291 7 /16 1 1/2 x 1 1/4 O.D.0.241 7 /16 901-7 DWV Trap Adapter C x SJ – Wrot APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1 1/4 x 1 1/4 O.D.0.21 21 /32 1 1/2 x 1 1/2 O.D.0.27 3 /4 1 1/2 x 1 1/4 O.D.0.24 7 /8 Consult price sheet for Made to Order items and for minimum order quantities.ADAPTERS – SOIL PIPE 805 DWV Soil Pipe Adapter C x Spigot – Cast Joins copper tube to cast iron soil pipes.APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1 1/4 x 20.933 9 /32 2 x 42.523 7 /8 31.562 3 /4 3 x 42.783 13 /16 42.233 905 DWV Soil Pipe Adapter C x Spigot – Wrot Joins copper tube to cast iron soil pipes.APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1 1/2 x 20.603 7 /16 20.442 9 /16 805-N DWV No Hub Soil Pipe Adapter C x No Hub – Cast APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1 1/2 x 20.421 7 /32 20.401 3 /16 30.751 3 /16 41.231 7 /32 801-T DWV Trap Adapter C x O.D. Tube – Cast APPROX.DIM. C NOM. SIZENET WT./LBS.INCHES 1 1/4 x 1 1/4 O.D.0.21 1 /8 1 1/2 x 1 1/2 O.D.0.22 7 /32 1 1/2 x 1 1/4 O.D.0.20 9 /32 802 DWV Adapter C x M – Cast APPROX.DIM. BDIM. C NOM. SIZENET WT./LBS.INCHESINCHES 1 1/40.23 15 /16 7 /16 1 1/4 x 1 1/2 0.411 1 /2 1 1/20.251 7 /16 20.331 1 /16 7 /16 30.921 1 /2 3 /4 802-C DWV Flush Adapter C x M – Cast APPROX.DIM. BDIM. C NOM. SIZENET WT./LBS.INCHESINCHES 1 1/40.16 15 /16 7 /16 1 1/20.20 15 /16 9 /16 20.231 1 /16 5 /8 802-F DWV Threaded Piece C x M – Cast Makes slip joint connection when soldered to the end of tube and slip joint nut and washer added.APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1 1/40.05 3 /8 1 1/20.05 3 /8 20.05 3 /8 803 DWV Adapter C x F – Cast APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 31.451 13 /32 42.311 17 /32 903 DWV Adapter C x F – Wrot APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1 1/40.19 27 /32 1 1/20.25 29 /32 20.411 ADAPTERS – THREADED continued ADAPTERS –THREADED AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 32 ADAPTERS –SPECIAL LEAD Consult price sheet for Made to Order items and for minimum order quantities.803-2 DWV Fitting Adapter Ftg x F – Cast APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1 1/20.391 15 /32 20.561 19 /32 31.442 7 /32 903-2 DWV Fitting Adapter Ftg x F – Wrot APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1 1/40.191 17 /32 804 DWV Adapter C x M – Cast APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1 1/20.341 3 /64 1 1/2 x 20.551 5 /16 1 1/2 x 1 1/40.31 27 /32 20.43 7 /8 2 x 1 1/20.52 15 /16 31.351 25 /32 42.592 1 /32 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 33 Consult price sheet for Made to Order items and for minimum order quantities.ADAPTERS –THREADED continued 904 DWV Adapter C x M – Wrot APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1 1/40.301 3 /32 1 1/4 x 1 1/20.371 3 /16 804-T DWV Trap Adapter O.D. Tube x M – Cast APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1 1/4 O.D. x 1 1/20.441 9 /32 804-2 DWV Fitting Adapter Ftg x M – Cast APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1 1/20.501 15 /16 20.712 1 /32 801-2 DWV External Bushing Ftg x C – Cast APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 3 x 20.611 11 /32 3 x 1 1/20.601 5 /16 4 x 31.121 21 /32 4 x 21.161 3 /4 901-2 DWV External Bushing Ftg x C – Wrot APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1 1/2 x 1 1/40.131 2 x 1 1/20.191 7 /32 2 x 1 1/40.191 3 /8 901-2-F DWV Fitting Flush Bushing Ftg x C – Wrot APPROX.DIM. BDIM. C NOM. SIZENET WT./LBS.INCHESINCHES 2 x 1 1/20.37 13 /16 1 /8 BUSHINGS CLEANOUTS 816 DWV Fitting Cleanout Ftg x Cleanout w/Plug – Cast APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1 1/40.492 5 /32 1 1/20.602 1 /4 20.872 3 /8 32.373 9 /32 43.993 5 /8 816-S DWV Flush Fitting Cleanout Ftg x Cleanout w/Plug – Cast APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1 1/4 x 3/40.201 5 /32 1 1/2 x 10.291 1 /16 2 x 1 1/20.421 7 /32 3 x 2 1/20.961 13 /16 4 x 32.252 1 /8 851 DWV Closet Flange C – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.BFW 41.45 5 /8 76 4 x 32.181 11 /16 76 951 DWV Closet Flange C – Wrot APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.BFW 4 x 30.841 11 /16 6 3 /4 6 851-C DWV Closet Flange C – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.BCFW 4 x 31.311 1 /16 1 /2 6 7 /8 6 CLOSET FLANGES AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 34 Consult price sheet for Made to Order items and for minimum order quantities.COUPLINGS 801 DWV Coupling C x C – Cast APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 3 x 20.70 11 /16 3 x 1 1/20.68 15 /16 4 x 30.98 9 /32 4 x 21.341 1 /4 901 DWV Coupling C x C – Wrot APPROX.DIM. A NOM. SIZENET WT./LBS.INCHES 1 1/40.07 3 /32 1 1/20.09 3 /32 1 1/2 x 1 1/40.13 5 /16 20.14 3 /32 2 x 1 1/20.19 15 /32 30.45 3 /32 40.57 1 /8 901-RP DWV Repair Coupling (No Stop)C x C – Wrot APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1 1/20.091 13 /32 20.141 17 /32 30.421 29 /32 40.572 13 /32 906-2 DWV 45°Fitting Elbow Ftg x C – Wrot APPROX.DIM. BDIM. C NOM. SIZENET WT./LBS.INCHESINCHES 1 1/40.131 3 /16 1 /2 1 1/20.211 1 /4 9 /16 20.391 5 /8 13 /16 30.841 7 /8 1 3 /8 807 DWV 90°Elbow C x C – Cast APPROX.DIM. CDIM. D NOM. SIZENET WT./LBS.INCHESINCHES 1 1/2 x 1 1/40.431 1 /4 1 3 /16 2 x 1 1/20.711 11 /16 1 7 /16 32.302 7 /8 2 7 /8 43.923 25 /32 3 25 /32 907 DWV 90°Elbow C x C – Wrot APPROX.DIM. CDIM. D NOM. SIZENET WT./LBS.INCHESINCHES 1 1/40.181 3 /16 1 3 /16 1 1/20.321 7 /16 1 7 /16 20.581 15 /16 1 15 /16 31.202 11 /16 2 11 /16 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 35 Consult price sheet for Made to Order items and for minimum order quantities.806 DWV 45°Elbow C x C – Cast APPROX.DIM. C NOM. SIZENET WT./LBS.INCHES 42.471 17 /32 906 DWV 45°Elbow C x C – Wrot APPROX.DIM. C NOM. SIZENET WT./LBS.INCHES 1 1/40.13 1 /2 1 1/20.21 9 /16 20.38 13 /16 30.781 3 /16 806-2 DWV 45°Fitting Elbow Ftg x C – Cast APPROX.DIM. BDIM. C NOM. SIZENET WT./LBS.INCHESINCHES 42.812 19 /32 1 17 /32 ELBOWS 907-LT DWV 90°Long Radius Elbow C x C – Wrot APPROX.DIM. C NOM. SIZENET WT./LBS.INCHES 1 1/20.412 5 /16 20.622 3 /4 807-2 DWV 90°Fitting Elbow Ftg x C – Cast APPROX.DIM. BDIM. C NOM. SIZENET WT./LBS.INCHESINCHES 43.844 13 /16 3 25 /32 907-2 DWV 90°Fitting Elbow Ftg x C – Wrot APPROX.DIM. BDIM. C NOM. SIZENET WT./LBS.INCHESINCHES 1 1/40.191 7 /8 1 3 /16 1 1/20.332 3 /16 1 7 /16 20.592 11 /16 1 7 /8 31.213 11 /16 2 11 /16 807-3 DWV 90°Elbow C x F – Cast APPROX.DIM. CDIM. E NOM. SIZENET WT./LBS.INCHESINCHES 1 1/20.721 13 /32 2 1 /8 21.151 7 /8 2 11 /16 807-4 DWV 90°Elbow C x M – Cast APPROX.DIM. CDIM. E NOM. SIZENET WT./LBS.INCHESINCHES 1 1/20.661 13 /32 2 3 /32 807-9 DWV 90°Elbow w/Side Inlet C x C x C – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CC 1 D 3 x 3 x 22.552 7 /8 1 5 /8 2 7 /8 960 DWV 60°Elbow C x C – Wrot APPROX.DIM. C NOM. SIZENET WT./LBS.INCHES 1 1/20.24 13 /16 20.441 1 /8 30.951 7 /8 861-LH DWV 90°Elbow w/Low Heel Inlet C x C x C – Cast APPROX.DIM. CDIM. E NOM. SIZENET WT./LBS.INCHESINCHES 3 x 3 x 22.432 7 /8 1 9 /32 818 A.S.A.DWV Plug M – Cast APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 3/40.08 23 /32 10.12 29 /32 1 1/40.19 31 /32 1 1/20.211 3 /32 20.34 15 /16 ELBOWS continued AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 36 Consult price sheet for Made to Order items and for minimum order quantities.837 DWV 90°Double Elbow C x C x C – Cast APPROX.DIM. CDIM. G NOM. SIZENET WT./LBS.INCHESINCHES 11/20.771 13 /32 1 13 /32 21.311 7 /8 1 7 /8 2 x 11/2 x 11/20.971 5 /8 1 1 /2 808 DWV 22 1 /2 °Elbow C x C – Cast APPROX.DIM. C NOM. SIZENET WT./LBS.INCHES 1 1/40.22 3 /16 1 1/20.28 1 /4 20.48 11 /32 30.99 17 /32 809 DWV 11 1 /4 °Elbow C x C – Cast APPROX.DIM. C NOM. SIZENET WT./LBS.INCHES 1 1/20.22 5 /32 20.38 3 /16 PLUGS 811-14 DWV Tee C x C x F – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.BFG 1 1/20.882 3 /16 13 /16 1 13 /32 21.572 23 /32 1 1 /16 1 7 /8 2 x 2 x 1 1/21.172 7 /16 7 /8 1 7 /16 811-15 DWV Tee C x F x F – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.BEG 1 1/40.731 25 /32 1 1 /2 1 5 /32 835 DWV Double Tee C x C x C x C – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CFG 1 1/40.651 5 /32 3 /4 1 5 /32 1 1/20.851 13 /32 13 /16 1 13 /16 11/2 x 11/2 x 11/4 x 11/40.721 9 /32 3 /4 15 /32 21.381 7 /8 1 1 /16 1 7 /8 2 x 2 x 1 1/2 x 1 1/20.991 21 /32 7 /8 1 7 /16 2 x 2 x 1 1/4 x 1 1/40.931 17 /32 25 /32 1 5 /32 2 x 1 1/2 x 1 1/2 x 1 1/20.941 21 /32 25 /32 1 7 /16 3 x 3 x 2 x 22.362 3 /8 1 1 /8 1 7 /8 3 x 3 x 1 1/2 x 1 1/21.512 5 /32 31 /32 1 15 /32 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 37 Consult price sheet for Made to Order items and for minimum order quantities.TEES 811 DWV Tee C x C x C – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CFG 32.842 53 /64 1 25 /64 2 53 /64 3 x 3 x 21.822 3 /8 1 1 /8 1 7 /8 3 x 3 x 1 1/21.582 5 /32 15 /16 1 7 /16 44.923 13 /16 23 13 /16 4 x 4 x 33.493 11 /32 1 19 /32 2 7 /8 4 x 4 x 22.912 7 /8 1 5 /32 1 13 /32 911 DWV Tee C x C x C – Wrot APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CFG 1 1/40.321 1 /8 13 /16 1 1 /8 1 1/20.491 13 /32 29 /32 1 13 /32 1 1/2 x 1 1/2 x 1 1/41.582 5 /32 15 /16 1 7 /16 20.781 27 /32 1 1 /8 1 7 /8 2 x 2 x 1 1/20.731 5 /8 15 /16 1 3 /8 2 x 2 x 1 1/40.511 1 /2 13 /16 1 1 /8 2 x 1 1/2 x 20.801 27 /32 1 25 /32 1 13 /16 2 x 1 1/2 x 1 1/20.731 5 /8 1 1 /4 1 3 /8 835-B DWV Double LT Tee C x C x C x C – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CDLM 2 x 11/2 x 11/2 x 11/21.732 3 /8 3 3 /16 3 21 /32 3 /32 917-B Test Caps – Copper C – Wrot APPROX.DIM. B NOM. SIZENET WT./LBS.INCHES 1/20.01 3 /16 3/40.01 3 /16 10.01 1 /8 1 1/40.01 1 /4 1 1/20.01 1 /4 20.02 1 /4 30.03 1 /4 40.05 5 /16 TEST CAPS 814 DWV Test Tee C x C x Cleanout w/Plug – Cast APPROX.DIM. EDIM. F NOM. SIZENET WT./LBS.INCHESINCHES 1 1/21.002 1 /16 1 1 /8 21.352 11 /32 1 3 /8 33.783 7 /16 1 15 /16 812 DWV Long Turn T-Y C x C x C – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CDJK §1 1/40.932 27 /32 1 27 /32 2 3 /4 13 /32 1 1/20.873 5 /16 2 1 /8 3 5 /32 7 /16 21.844 1 /4 2 3 /4 4 1 /16 1 /2 2 x 2 x 1 1/21.073 5 /8 2 3 /8 3 7 /32 7 /32 33.496 7 /16 4 1 /32 6 1 /32 3 /4 3 x 3 x 22.784 7 /8 3 5 /16 4 5 /32 3 /32 836 DWV Double Long Turn T-Y C x C x C x C – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CDJK 1 1/21.253 5 /16 2 1 /8 3 5 /32 7 /32 20.873 5 /16 2 1 /8 3 5 /32 7 /16 2 x 2 x11/2 x11/21.963 5 /8 2 3 /8 3 7 /32 7 /32 2 x 2 x11/4 x11/42.673 11 /16 2 3 /8 3 7 /32 7 /32 T-Y’s AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 38 Consult price sheet for Made to Order items and for minimum order quantities.TEST TEES Y’s continued 810 DWV 45°Y C x C x C – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CDKL 1 1/40.6022 3 /8 –1 1/20.942 5 /16 2 5 /16 1 /2 –21.262 7 /8 2 7 /8 17 /32 –2 x 2 x 1 1/21.152 11 /16 2 9 /16 3 /16 –2 x 2 x 1 1/41.012 9 /16 2 11 /32 1 /16 –2 x 11/2 x 21.162 17 /32 2 5 /8 17 /32 –2 x 11/2 x 11/20.842 5 /32 2 5 /32 5 /16 –33.194 1 /64 4 1 /64 45 /64 –3 x 3 x 22.023 17 /32 3 5 /16 1 /8 –3 x 3 x 1 1/21.693 1 /4 2 15 /16 –3 /16 45.555 15 /32 5 15 /32 1 1 /16 –4 x 4 x 33.964 11 /16 4 1 /2 5 /16 –4 x 4 x 22.904 7 /32 3 13 /16 –3 /8 834 DWV 45°Double Y C x C x C x C – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CDKL 21.902 7 /8 2 7 /8 17 /32 –2 x 2 x11/2 x11/21.262 11 /16 2 9 /16 3 /16 –34.204 13 /32 4 13 /32 25 /32 –3 x 3 x11/2 x11/22.093 1 /4 2 15 /16 –5 /16 881 DWV P-Trap C x SJ – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.AEJK 1 1/21.501 13 /32 2 7 /32 2 1 /2 3 17 /32 884 DWV P-Trap w/Cleanout C x C x Cleanout w/Plug – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.ACJK 1 1/41.211 5 /32 1 17 /32 2 1 /4 3 9 /32 1 1/21.531 13 /32 1 15 /32 2 1 /2 3 17 /32 22.261 7 /8 1 13 /32 34 3 /32 35.742 7 /8 1 15 /16 45 21 /32 885 DWV P-Trap C x C – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.ACJK 1 1/41.091 5 /32 1 17 /32 2 1 /4 3 9 /32 1 1/21.451 13 /32 1 15 /32 2 1 /2 3 17 /32 22.111 7 /8 1 13 /32 34 3 /32 35.172 7 /8 1 15 /16 43 21 /32 890 3 x 5 DWV Drum Trap w/Bottom Inlet C x F x Cleanout w/Plug – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.BCE 1 1/21.973 9 /32 1 1 /2 2 3 /8 891 3 x 6 DWV Swivel Drum Trap C x C x Cleanout w/Plug – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.BCFJ 1 1/22.906 21 /32 1 1 /2 13 7 /8 880 DWV P-Trap w/Cleanout CxSJxCleanout w/Plug–Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.AEJK 1 1/21.801 13 /32 2 7 /32 2 1 /2 3 17 /32 22.661 7 /8 2 7 /16 34 3 /16 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 39 Consult price sheet for Made to Order items and for minimum order quantities.TRAPS 892 DWV P-Trap w/Union Joint C x SJ – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.AEJK 1 1/21.861 1 /8 3 5 /32 2 5 /8 3 7 /16 22.641 15 /32 3 13 /32 3 1 /8 3 29 /32 892-3 DWV P-Trap w/Union Joint F x SJ – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.AEJK 22.891 13 /32 3 13 /32 3 1 /8 3 29 /32 892-A DWV P-Trap w/Union Joint FxSJxCleanoutw/Plug–Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.AEJK 1 1/21.881 15 /16 2 7 /32 2 1 /2 3 17 /32 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 40 879 DWV Return Bend C x C – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CJL 1 1/40.761 17 /32 2 1 /4 –1 1/20.901 15 /32 2 1 /2 –1 1/2 x 1 1/2 O.D.1.001 15 /32 2 1 /2 –21.251 13 /32 3–2 x 1 1/2 O.D.1.231 17 /32 31 19 /32 2x11/21.371 17 /32 31 19 /32 32.771 15 /16 4–875-S DWV Trap Upturn M x S – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.BEJ 1 1/21.201 41 /64 1 9 /64 4 Consult price sheet for Made to Order items and for minimum order quantities.TRAPS cont.RETURN BENDS 878 DWV Return Bend w/Cleanout C x C x Cleanout w/Plug – Cast APPROX.DIMENSIONS NET WT.INCHES NOM. SIZELBS.CJ 1 1/40.811 17 /32 2 1 /4 –1 1/20.981 15 /32 2 1 /2 –21.401 13 /32 3–33.341 15 /16 4– AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 41 Engineering Data continued Solder Joint Fittings Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 Friction Loss Allowances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 Installation Techniques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85 Tolerances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 Specifications Tolerances Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44, 48-49 Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50-53 Valves Friction Loss Allowances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 Working Pressures Joints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46-47 Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50-53, 57 Installation Instructions The Fine Art of Brazing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86-87 The Fine Art of Soldering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85 Polybutylene Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89 Polyethylene (PEX) Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88 Numerical Index Numerical Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92 Engineering Data Brazing Alloy Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 Brazing Fittings Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 Friction Loss Allowances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 Installation Techniques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86-87 Tolerances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 Copper Tube Fittings Brazing Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 Fitting Terms and Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42 Plumbing System Failures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 Rated Internal Working Pressures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46-47 Solder and Flux Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 Solder Joint Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 Tolerances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63 Types of Joints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42 Copper Water Tube Comparative Data with Iron Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50-53 Expansion and Contraction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 Internal Working Pressures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57 Selection of Tube Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 Tolerances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50-53 Types, Standards, Applications, Tempers and Lengths . . . . . . . . . . . . . . . . . .84 Water Flow and Friction Loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58-83 Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90 Joints Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42 Brazing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86-87 Soldering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85 Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42 Solder and Flux Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 The manufacturing plants at South Glens Falls, NY, Stuarts Draft, VA, Nacogdoches, TX and Reynosa, Mexico manufacture products under a Quality Management System conforming to the current revision of ISO-9001 International Standards AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 42 TYPES OF JOINTS Flared Joint — The principle of the flared joint was first developed for copper tube plumbing in 1928 by NIBCO. The flared type joint is wholly a mechanical means of joining copper tubes. The tube nut is placed over the end of the copper tube to be joined; the tube end then is flared out at an approximate 45 degree angle by a flaring tool. The flared end is then drawn up by the tube nut so the inside surface is tightly secured against the ball seat of the fitting. This joint can be readily dismantled at any time and is, in effect, a type of union connection. Its use is generally restricted to soft (annealed) copper tubes since hard drawn tubes would be subject to splitting when flared (if the ends were not previously annealed). The flared ends of NIBCO Flared Fittings are produced to the requirements of ASME B16.26, “Cast Copper Alloy Fittings for Flared Copper Tube.”Solder Joint — NIBCO pioneered the development of the solder joint and its application to the field of copper tube piping.Today the solder joint is widely adopted, as evidenced by the majority of cities and states that have written codes to include copper tube and solder joints as desirable for general plumbing,water lines, vent, stack, waste and drain lines, as well as other uses in industry. Testing has shown that often the solder joint has greater strength than the tubes being joined, depending upon the soldering alloy selected. While the method of preparing a solder joint is an exacting art to insure a full strength joint, it can be readily mastered by skilled tradesmen. It is for this reason — to insure the public of the protection afforded by properly prepared joints — that NIBCO products are marketed through the reputable sources of supply to the piping trades. Important procedures for preparing a solder joint are graphically illustrated in this catalog on page 95.Brazed Joint — This type of joint has long been used wherever and whenever critical situations have been encountered in copper piping.The joint itself is completed much in the same manner as the solder joint; however, considerably more heat and several refinements of technique require separate procedures that are described further in this catalog on pages 96-97.Threaded Ends — To adapt copper tube to equipment having National Standard Pipe Taper (NPT) threads or to add copper tube to existing iron pipe installations or other threaded connections, NIBCO provides fittings having both external and internal NPT threads.These threaded ends are produced to the requirements of ASME B1.20.1, “Pipe Threads, General Purpose (Inch).”Flanges — To adapt copper tube to equipment having flanged connections, or to add copper tube to flanged pipe installations or other purposes, NIBCO provides flanges. The flanges are produced in two standard types widely used in this field where copper tube can serve — Class 150, comply with ASME B16.24, “Cast Copper Alloy Pipe Flanges and Flanged Fittings Class 150, 300, 400, 600, 900, 1500 and 2500”; and Class 125, which conform to MSS SP 106, “Cast Copper Alloy Flanges and Flanged Fittings Class 125, 150 and 300.”Barbed Insert Fittings for Polybutylene (PB) — NIBCO offers a complete line of copper barbed insert fittings for joining PB tube. The insert fittings are produced to the requirements of ASTM F 1380.Along with the insert fittings are copper crimp rings, which, when properly installed, provide a leak-tight mechanical joint. Transition fittings are available for adapting to new or existing threaded or solder joint ends.Barbed Insert Fittings for PEX — NIBCO offers a complete line of copper barbed insert fittings for joining PEX tube. The insert fittings are produced to the requirements of ASTM F 1807. Along with the insert fittings are copper crimp rings, which, when properly installed,provide a leak-tight mechanical joint. Transition fittings are available for adapting to new or existing threaded or solder joint ends.Fitting Terms and Abbreviations C Female solder cup Ftg Male solder end F Female NPT thread M Male NPT thread Hose Standard hose thread Hub Female end for soil pipe Spigot Male end for soil pipe No Hub Used with mechanical coupling O.D. Tube Actual tube outside diameter S Straight thread SJ Slip joint FLFlared Copper Tube Fittings AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 43 WHAT MAKES A PLUMBING SYSTEM FAIL?F ailure in a copper plumbing system is rare, but may occur due to a variety of reasons. The most common causes of failure are:1.Excessive fluid velocity causes erosion-corrosion or impingement (to strike or hit against) attack in the tube and/or fitting. For this reason, the copper plumbing industry has establish design velocity limits for copper plumbing systems to the following:Hot Water > 140°F (60°C)2 to 3 feet per second (0.6 to 0.9 meters per second)Hot W ater 140°F (60°C)4 to 5 feet per second (1.2 to 1.5 meters per second)Cold Water5 to 8 feet per second (1.5 to 2.4 meters per second)2.Localized high velocities and/or turbulence. The presence of a dent, tube ends which are not reamed or deburred before soldering, and sudden changes in direction can all cause localized high velocity conditions.3.Flux Corrosion is typified by pin hole leaks, generally in the bottom of a horizontal line. Fluxes are mildly corrosive liquid or petroleum-based pastes containing chlorides of zinc and ammonia. Unless the flux is flushed from the system, it will lay in the bottom of the tube and remain active. ASTM B 813, “Liquid and Paste Fluxes for Soldering Applications of Copper and Copper-Alloy Tube,” limits the corrosivity of soldering fluxes and ensures that these fluxes are flushable in cold water, which facilitates easy removal of flux residue following installation.4.Galvanic Corrosion may be defined as the destruction of a material by electrochemical interaction between the environment and the material.Generally, it is slow but persistent in character and requires the presence of dissimilar metals. Galvanic corrosion requires the flow of an electric current between certain areas of dissimilar metal surfaces. To complete the electric circuit, there must be two electrodes, an anode and a cathode,and they must be connected by an electrolyte media (water) through which the current can pass. The amount of metal which dissolves at the anode is proportional to the number of electrons flowing, which in turn is dependent upon the potential and resistance of the two metals. The use of dissimilar metals in a plumbing system may or may not create a problem. For instance, copper and steel are perhaps the most common dissimilar metals found together in a plumbing system. In closed systems,such as a chilled or heating water piping, the use of dissimilar metals may not create a serious problem; this is because there is virtually no oxygen in the water and corrosion relations tend to be stifled. Where dissimilar metals must be used, some codes require that they should be separated by dielectric union or a similar type of fitting. The effectiveness depends upon; distance between the metals on the electromotive-force series (EMF) chart, ratio of cathode to anode area, degree of aeration, amount of agitation, temperature, presence of dissolved salts, and other factors.ABBREVIATED EMF SERIES (Electromotive-Force Series; Common Piping Materials in Sea Water)CATHODE (+) Passive GOLD – Fixtures, Faucets, Plating PLATINUM SILVER – Brazing alloys, Silver-bearing solders TITANIUM – Condenser tubes MONEL (67% Ni -33% Cu) – Specialty piping & equipment CUPRO-NICKEL – Condensers, Marine, Nuclear COPPER – Pressure, DWV, Gases, Air, Refrigeration, etc.BRASS (85/15 -Red) – Cast fittings, Valves BRASS (70/30 -Yellow) – Gas-cocks, Fittings, Connectors LEAD – Solder, Pipe, Sheet, Coating, Lining TIN – Solders, Coating, Lining CAST IRON – Pressure, DWV WROUGHT IRON – Pressure MILD STEEL – Fire Protection ALUMINUM – Refrigeration, Irrigation, some Solar GALVANIZED STEEL – Pressure, DWV ZINC – Coatings, Linings, some Fittings MAGNESIUM – Water Heater Anodes, Cathodic protection for pipelines ANODE (-) Active; Sacrificial Material 5.Dezincification is a type of corrosion in which brass dissolves as an alloy and the copper constituent redeposits from solution onto the surface of the brass as a metal, but in the porous form. The zinc constituent may be carried away from the brass as a soluble salt, or may be deposited in place as an insoluble compound. Dezincification is normally associated with brass valves where the zinc content exceeds 15%. Generally, areas of high stress, such as valve stems and gate valve bodies, are primary targets of attack.6.On rare occasion problems of corrosion by aggressive water, possibly aggravated by poor design or workmanship, do exist. Aggressive, hard well waters that cause pitting can be identified by chemical analysis and treated to bring their composition within acceptable limits. Typically these hard waters are found to have high total dissolved solids (t.d.s.) including sulfates and chlorides, a pH in the range of 7.2 to 7.8, a high content of carbon dioxide (CO2) gas (over 10 parts per million, ppm), and the presence of dissolved oxygen (D.O.) gas. Soft acidic waters can cause the annoying problem of green staining of fixtures or “green water”. Raising the pH of such waters to a value of about 7.2 or more usually solves the problem, but a qualified water treatment specialist should be consulted.7.Aggressive soil conditions can be a cause for external corrosion of copper piping systems. Non-uniform soil characteristics, such as different soil aeration, resistivity, or moisture properties, between adjacent sections of tube can create galvanic corrosion cells. Soils contaminated with high concentrations of road salts or fertilizers containing ammonia, chlorides,and nitrogen are known to combine with water to form acids. Any metal pipe laid in ash or cinders is subject to attack by the acid generated when sulfur compounds combine with water to form sulfuric acid.U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. 1.Soldering Clearance (between the outside of the tube and the inside diameter of the solder cup) and the Depth of the Solder Cup (into which the tube is inserted).Chart 1 – Soldering Clearance and Solder Cup Depth NominalMaximumMinimumMaximumDepth of SizeI.D. ofO.D. ofClearanceSolder Cup of FittingFittingTubefor Soldering (Inches)Inch(mm)Inch(mm)Inch(mm)Inch(mm)1/40.381(9.66)0.374(9.50)0.007(0.18)0.31(7.9)3/80.506(12.85)0.499(12.67)0.007(0.18)0.38(9.7)1/20.631(16.03)0.622(15.85)0.009(0.18)0.50(12.7)5/80.756(19.20)0.749(19.02)0.007(0.18)0.62(15.7)3/40.881(22.38)0.872(22.20)0.009(0.18)0.75(19.1)11.132(28.75)1.123(28.54)0.008(0.216)0.91(23.1)1 1/41.382(35.10)1.373(34.88)0.008(0.216)0.97(24.6)1 1/21.633(41.48)1.623(41.22)0.010(0.25)1.09(27.7)22.133(54.18)2.123(53.92)0.010(0.25)1.34(34.0)2 1/22.633(66.88)2.623(66.62)0.010(0.25)1.47(37.3)33.133(79.58)3.123(79.32)0.010(0.25)1.66(42.2)3 1/23.633(92.28)3.623(92.02)0.010(0.25)1.91(48.5)44.133(104.98)4.123(104.72)0.010(0.25)2.16(54.9)55.133(130.38)5.123(130.12)0.010(0.25)2.66(67.6)66.133(155.78)6.123(155.52)0.010(0.25)3.09(78.5)The National Bureau of Standards Report BMS58, “Strength of Soft-Soldered Joints in Copper Tubing,” reporting on tests conducted with 3 /4 -inch tubing and fitting, says “When the clearance is greater than 0.010 inch (0.25 mm), there is difficulty in filling the joint properly.”2.Depth of Solder Penetration drastically affects the breaking load of the joint. When there is too great a soldering clearance,there is no capillary flow to assure complete solder penetration.As shown in the chart below, the holding power of the 3 /4 -inch joint is directly proportional to the depth of solder penetration. For example: If you get only one-third penetration, you get approximately one-third the strength needed to assure complete satisfaction.Chart 2 – Type K 3 /4 " Tubing AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 44 SOLDER JOINT SPECIFICATION Copper Tube Fittings continued HOW TO BE SURE OF PROPER TOLERANCES It is apparent that all of the scientific apparatus used to test tube and fittings, according to the dimensions indicated in Chart 1, would be impractical to use on the job. It is therefore essential that you install tube and fittings manufactured by companies known to be dedicated to the highest quality control standards. Should you encounter a condition where there is difficulty in filling the joint properly, NIBCO will analyze the trouble without charge. Just send six inches of the tube, along with the fitting and our technicians will provide you with an authoritative report.Solder penetration of one-third the cup depth — breaking load,approximately 2,100 lb. (955 kg)Solder penetration of the entire cup depth — breaking load approximately 7,000 lb. (3175 kg)U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 45 BRAZING INFORMATION For Estimating Purposes Copper Water Tube SizeBrazing A Filler Required Torch Tip Acetylene ConsumptionOxygen Pressure (Approx.)Acetylene Pressure (Approx.)(In Inches)Inches(mm)Drill Size No.C.F.H.(C.M.H.)PSI(kPa)PSI(kPa)1/40.25 B (6.4)5415.9(0.5)4(27)4(27)3/80.38 B (9.7)5415.9(0.5)4(27)4(27)1/20.50(12.7)5124.8(0.7)5(34)5(34)5/80.62(15.7)5124.8(0.7)5(34)5(34)3/41.00(25.0)5124.8(0.7)5(34)5(34)11.60(41.0)4831.6(0.9)6(41)6(41)1 1/42.00(51.0)4831.6(0.9)6(41)6(41)1 1/22.60(66.0)4438.7(1.1)7(48)7(48)24.40(112.0)4060.0(1.7)7(48)7(48)2 1/25.90(150.0)4060.0(1.7)7(48)7(48)37.90(200.0)3570.0(2.0)7 1 /2 (52)7 1 /2 (52)3 1/210.50(207.0)3570.0(2.0)7 1 /2 (52)7 1 /2 (52)413.50(343.0)3088.5(2.5)9(62)9(62)520.50(521.0)3088.5(2.5)9(62)9(62)628.50(724.0)3088.5(2.5)9(62)9(62)A Approximate consumption when brazing one cup of the fitting. Actual consumption depends on workmanship. For filler sizes shown, one pound of filler alloy provides 1,068 inches (27.13 mm) of 1 /16 -inch wire or 475 inches (12,065 mm) of 3 /32 -inch wire.B 1 /16 -inch (1.59 mm) diameter wire; all other is 3 /32 -inch (2.38 mm) diameter.SOLDER AND FLUX REQUIREMENTS Nom. Size Joint Solder Required, LB (kg)(In Inches)General UseDrainage Use 1/40.097–3/80.159–1/20.261–5/80.389–3/40.548–10.856–1 1/41.1151.2(0.5)1 1/21.4801.4(0.6)22.3801.5(0.7)2 1/23.225–34.3352.8(1.3)3 1/25.786–47.4464.2(1.9)511.392–615.815–826.955–Solder requirements in this table are based on estimate of weight of solder used to prepare 100 solder joints of sizes shown.Two (2) ounces (0.06 kg) of solder flux will be required for each pound (0.45 kg) of solder.U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 3 3 //2 2 9 9 //0 0 4 4 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 46 Copper Tube Fittings continued RATED INTERNAL WORKING PRESSURES OF JOINTS MADE WITH FLARED FITTINGS AND COPPER WATER TUBE Nominal Size Joint (In Inches)Temperature, °F(°C)A Pressure, PSI (BAR)A 3/8, 1/2, 3/4, 1, 1 1/4, 1 1/2, 2100(38)175(12)A ASME B16.26 RATED INTERNAL WORKING PRESSURES OF POLYBUTYLENE TUBE AND COPPER BARBED INSERT FITTINGS Nominal Size Joint (In Inches)Temperature, °F (°C)Pressure, PSI (BAR)3/8, 1/2, 3/4, 173(23)200(14)140(60)160(11)180(82)100(7)200(93)80(5)RATED INTERNAL WORKING PRESSURES OF JOINTS MADE WITH COPPER WATER TUBE AND SOLDER TYPE FITTINGS, PSI (BAR)Maximum Gauge Working Pressure for Standard Water Tube Sizes [Note (1)]Saturated Steam Working Temperature 1 /8 " though 1"1 1 /4 " through 2"2 1 /2 " through 4"5" through 8"10" to 12"LB (kg)Joining Material°F°CPSIBARPSIBARPSIBARPSIBARPSIBARAll Sizes Alloy Sn50 10038200(14)175(12)150(10)135(9)100(6)50-50 Tin-Lead solder 15066150(10)125(9)100(7)90(6)70(5)15 [Notes (2), (3)]20093100(7)90(6)75(5)70(5)50(3)25012185(6)75(5)50(3)45(3)40(3)Alloy Sb5 100381090 (9)(75)850 (8)(59)705 (9)(49)660 (8)(46)340(23)95-5 Tin-Antimony solder 15066625 (10)(43)485 (10)(34)405 (10)(28)375 (10)(26)280(19)15 [Note (4)]20093505 (11)(35)395 (10)(27)325 (10)(32)305 (10)(21)230(16)250121270(19)210(15)175(12)165(11)120(8)Alloy E 10038710 (10)(49)555 (10)(38)460 (10)(32)430 (10)(30)320(22)15066475 (11)(33)370 (10)(26)305 (10)(21)285 (11)(20)215(15)15 20093375(26)290(20)240 (11)(17)225 (11)(16)170(12)250121320(22)250(17)205(14)195(13)145(9)Alloy HB 100381035 (9)(71)805 (8)(56)670 (8)(46)625 (9)(43)340(23)[Note (6)]15066710 (10)(49)555 (10)(38)460 (10)(32)430 (10)(30)320(22)15 20093440 (11)(30)345 (11)(24)285 (11)(20)265 (11)(18)200(14)250121430 (11)(30)335 (11)(23)275 (11)(19)260 (11)(18)195(13)Joining materials at or above 593°CPressure-temperature ratings consistent with the materials and procedures employed.[Note (7)]GENERAL NOTE:For extremely low working temperatures in the 0°F to 200°F range, it is recommended that a joint material melting at or above 1 000°F be employed [see Note (5)].NOTES:(1)Standard water tube sizes per ASTM B 88 (2)ASTM B 32 Alloy Grade Sn50 (3)The Safe Drinking Water Act Amendment of 1986 prohibits the use of any solder having a lead content in excess of 0.2% in potable water systems.(4)ASTM B 32 Alloy Grade Sb5 (5)ASTM B 32 Alloy Grade E (6)ASTM B 32 Alloy Grade HB (7)These joining materials are defined as brazing alloys by the American Welding Society.(8)The solder joint exceeds the strength of Types K, L & M tube in drawn and annealed tempers.(9)The solder joint exceeds the strength of Types L & M tube in drawn temper and Type K tube in annealed temper.(10)The solder joint exceeds the strength of Type M tube in drawn temper and Types L &K in annealed temper.(11)The solder joint exceeds the strength of Type L tube in annealed temper.U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. RATED INTERNAL WORKING PRESSURE 1 FOR COPPER FITTINGS, PSI(BAR)Water Temperature Range Nominal Water Tube Size -20° to 100°F150°F200°F250°F300°F350°F400°F (In Inches)(-29° to 38°C)(66°C)(95°C)(120°C)(149°C)(177°C)(204°C)1/4912(62)775(53)729(50)729(50)714(49)608(42)456(31)3/8779(54)662(46)623(43)623(43)610(42)519(36)389(27)1/2722(50)613(42)577(40)577(40)565(39)481(33)361(25)5/8631(43)537(37)505(35)505(35)495(34)421(29)316(21)3/4582(40)495(34)466(32)466(32)456(31)388(27)291(20)1494(34)420(29)395(27)395(27)387(26)330(23)247(17)1 1/4439(30)373(26)351(24)351(24)344(23)293(20)219(15)1 1/2408(28)347(24)327(23)327(23)320(22)272(19)204(14)2364(25)309(21)291(20)291(20)285(20)242(17)182(13)2 1/2336(23)285(20)269(19)269(19)263(18)224(15)168(12)3317(22)270(19)254(17)254(17)248(17)211(15)159(11)3 1/2304(21)258(18)243(17)243(17)238(16)202(14)152(10)4293(20)249(17)235(16)235(16)230(16)196(13)147(10)5269(19)229(16)215(15)215(15)211(15)179(12)135 1 (9)6251(17)213(15)201(14)201(14)196(14)167(12)125 1 (8)8270(19)230(16)216(15)216(15)212(15)180(12)135 1 (9)1 The fitting pressure rating applies to the largest opening of the fitting.AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 47 RATED INTERNAL WORKING PRESSURES OF CAST COPPER ALLOY FLANGES AND FLANGED FITTINGS Pressure (PSI)Nominal Size JointTemperature (In Inches)°F (°C) A Class 125 A, B Class 150 B Class 150 A, C 1/2, 3/4,1, 1 1/4, 0 – 150(0 – 66)105(7)210(14)225(15)1 1/2, 2, 2 1/2, 175 1 (79)100(7)205(14)220(15)3, 4, 5, 6, 8200 1 (93)1 95(7)195(13)210(15)(also 10" for225(107)1 90(6)190(13)205(14)Class 125)250(121)1 90(6)180(12)195(13)275(135)1 85(6)175(12)190(13)300(149)1 85(6)170(12)180(12)350(177)1 75(5)150(10)165(11)406(208)1 70(5)140 1 (9)150(10)A MSS SP-106 B ASTM B584, UNS C83800 and UNS C84400 C ASTM B62, UNS C83600 and ASTM B584, UNS C83600 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 48 Copper Water Tube DIMENSIONAL DATA – SOLDER JOINT FITTING ENDS Solder Joint Fittings – TolerancesSolder Joint FittingsSolder Joint Fittings Copper Alloy – Pressure 1, 2 Copper Alloy – Drainage 3, 4 Male End (Fitting Connector)Female End (Solder Cup)NominalDiameterDiameterFitting End LengthSolder Cup LengthFitting End LengthSolder Cup Length Water TubeMin.Max.Min.Max.Min.Min.Min.Min.Size (In Inches)Inch(mm)Inch(mm)Inch(mm)Inch(mm)Inch(mm)Inch(mm)Inch(mm)Inch(mm)1/80.248(6.30)0.251(6.38)0.252(6.40)0.256(6.50)0.31(7.9)0.25(6.4)N/AN/AN/AN/A 1/40.373(9.47)0.376(9.55)0.377(9.58)0.381(9.68)0.38(9.7)0.31(7.9)N/AN/AN/AN/A 3/80.497(12.62)0.501(12.73)0.502(12.75)0.506(12.85)0.44(11.2)0.38(9.7)N/AN/AN/AN/A 1/20.622(15.80)0.626(15.90)0.627(15.93)0.631(16.03)0.56(14.2)0.50(12.7)N/AN/AN/AN/A 5/80.747(18.97)0.751(19.08)0.752(19.10)0.756(19.20)0.69(17.5)0.62(15.7)N/AN/AN/AN/A 3/40.872(22.15)0.876(22.25)0.877(22.28)0.881(22.38)0.81(20.6)0.75(19.1)N/AN/AN/AN/A 11.122(28.50)1.127(28.63)1.128(28.65)1.132(28.75)0.97(24.6)0.91(23.1)N/AN/AN/AN/A 1 1/41.372(34.85)1.377(34.98)1.378(35.00)1.382(35.10)1.03(26.2)0.97(24.6)0.56(14.2)0.50(12.7)1 1/21.621(41.17)1.627(41.33)1.628(41.35)1.633(41.48)1.16(29.5)1.09(27.7)0.62(15.7)0.56(14.2)22.121(53.87)2.127(54.03)2.128(54.05)2.133(54.18)1.41(35.8)1.34(34.0)0.69(17.5)0.62(15.7)2 1/22.621(66.57)2.627(66.73)2.628(66.75)2.633(66.88)1.53(38.9)1.47(37.3)N/AN/AN/AN/A 33.121(79.27)3.127(79.43)3.128(79.45)3.133(79.58)1.72(43.7)1.66(42.2)0.81(20.6)0.75(19.1)3 1/23.621(91.97)3.627(92.13)3.628(92.15)3.633(92.28)1.97(50.0)1.91(48.5)N/AN/AN/AN/A 44.121(104.67)4.127(104.83)4.128(104.85)4.133(104.98)2.22(56.4)2.16(54.9)1.06(26.9)1.00(25.4)55.121(130.07)5.127(130.23)5.128(130.25)5.133(130.38)2.72(69.1)2.66(67.6)1.31(33.3)1.25(31.8)66.121(155.47)6.127(155.63)6.128(155.65)3.133(79.58)3.22(81.8)3.09(78.5)1.62(41.1)1.50(38.1)88.119(206.22)8.127(206.43)8.128(206.45)8.133(206.58)4.09(103.9)3.97(100.8)2.12(53.8)2.00(50.8)1010.119(257.02)10.127(257.23)10.128(257.25)10.133(257.38)4.12(104.6)4.00(101.6)N/AN/AN/AN/A 1212.119(307.82)12.127(308.03)12.128(308.05)12.133(308.18)4.62(117.3)4.50(114.3)N/AN/AN/AN/A 1 As shown Standard ASME B16.18 2 As shown Standard ASME B16.22 3 As shown Standard ASME B16.23 4 As shown Standard ASME B16.29 The mechanics of making both the solder joint and the brazing joint are comparatively similar. Complete instructions on proper techniques of both of these joining methods are outlined in this catalog on pages 85-97.A very important consideration in Copper Piping is the selection of the proper bonding medium. As a general rule, the working temperature of the installation is a more important consideration than the working pressures. If the working temperature is not over 250°F (121°C), either 50-50%* or 95-5% solder can be used successfully. However, if the temperature exceeds 250°F (121°C), a lo w temperature brazing alloy should be used, with a melting temperature somewhat in excess of 1000°F (538°C).According to BMS report No. 58, joints made with tin or tin-alloy solders should not be subject continuously to temperatures ab ove 250°F (121°C).A number of brazing alloys are available and a careful study should be made in every case to determine the proper alloy for the particular application.*The Safe Drinking Water Act Amendment of 1986 prohibits the use in potable water systems of any solder having a lead content i n excess of 0.2%.U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 49 DIMENSIONAL DATA – BRAZING FITTING ENDS Male End (Fitting Connector) DiameterFemale End (Brazing Cup) DiameterFitting End Solder Cup LengthLength NominalMin.Max.Min.Max.Min.Min.Water Tube Size (In Inches)Inch(mm)Inch(mm)Inch(mm)Inch(mm)Inch(mm)Inch(mm)1/40.373(9.47)0.376(9.55)0.377(9.58)0.381(9.68)0.23(5.8)0.17(4.3)3/80.497(12.62)0.501(12.73)0.502(12.75)0.506(12.85)0.26(6.6)0.20(5.1)1/20.622(15.80)0.626(15.90)0.627(15.93)0.631(16.03)0.28(7.1)0.22(5.6)5/80.747(18.97)0.751(19.08)0.752(19.10)0.756(19.20)N/AN/AN/AN/A 3/40.872(22.15)0.876(22.25)0.877(22.28)0.881(22.38)0.31(7.9)0.25(6.4)11.122(28.50)1.127(28.63)1.128(28.65)1.132(28.75)0.34(8.6)0.28(7.1)1 1/41.372(34.85)1.377(34.98)1.378(35.00)1.382(35.10)0.37(9.4)0.31(7.9)1 1/21.621(41.17)1.627(41.33)1.628(41.35)1.633(41.48)0.40(10.2)0.34(8.6)22.121(53.87)2.127(54.03)2.128(54.05)2.133(54.18)0.47(11.9)0.40(10.2)2 1/22.621(66.57)2.627(66.73)2.628(66.75)2.633(66.88)0.53(13.5)0.47(11.9)33.121(79.27)3.127(79.43)3.128(79.45)3.133(79.58)0.59(15.0)0.53(13.5)3 1/23.621(91.97)3.627(92.13)3.628(92.15)3.633(92.28)0.65(16.5)0.59(15.0)44.121(104.67)4.127(104.83)4.128(104.85)4.133(104.98)0.72(18.3)0.64(16.3)55.121(130.07)5.127(130.23)5.128(130.25)5.133(130.38)0.81(20.6)0.73(18.5)66.121(155.47)6.127(155.63)6.128(155.65)3.133(79.58)0.94(23.9)0.83(21.1)88.119(206.22)8.127(206.43)8.128(206.45)8.133(206.58)1.28(32.5)1.17(29.7)1010.119(257.02)10.127(257.23)10.128(257.25)10.133(257.38)N/AN/AN/AN/A 1212.119(307.82)12.127(308.03)12.128(308.05)12.133(308.18)N/AN/AN/AN/A 1 In accordance with MS SP-73 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 50 Copper Water Tube continued U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents.DIMENSIONAL DATA – COPPER WATER TUBE – TYPE “K”TYPE “K”Hard Drawn:20-ft. (6.1m) Straight Lengths Soft Annealed:20-ft. (6.1m) Straight Lengths, or 40-ft. (12.2m) and 60-ft. (18.3m) Length Coils (to and including size 1 1/2)Usage:For underground service and general purpose plumbing and heating installations under severe conditions.TolerancesHard DrawnSoft Annealed (Hard Drawn Only)OutsideTubing ODNominal WallWeightBurstingSafe WorkingBurstingSafe Working NominalDiameterThicknessPer FootPressure A Pressure B Pressure A Pressure C Water TubeMin.Max.Size (In Inches)Inch(mm)Inch(mm)Inch(mm)Inch(mm)Lb(kg)psi(bars)psi(bars)psi(bars)psi(bars)1/40.375(9.53)0.373(9.47)0.376(9.55)0.035(0.89)0.145(0.07)N/AN/A1612 (111)N/AN/A913 (63)3/80.500(12.70)0.497(12.62)0.501(12.73)0.049(1.24)0.269(0.12)N/AN/A1675 (115)N/AN/A960 (66)1/20.625(15.88)0.622(15.80)0.626(15.90)0.049(1.24)0.344(0.16)9840 (678)1337 (92)4535 (313)758 (52)5/80.750(19.05)0.747(18.97)0.751(19.08)0.049(1.24)0.418(0.19)N/AN/A1104 (76)N/AN/A626 (43)3/40.875(22.23)0.872(22.15)0.876(22.25)0.065(1.65)0.641(0.29)9300 (641)1278 (88)4200 (290)724 (50)11.125(28.58)1.122(28.50)1.127(28.63)0.065(1.65)0.839(0.38)7200 (496)982 (68)3415 (235)557 (38)1 1/41.375(34.93)1.372(34.85)1.377(34.98)0.065(1.65)1.040(0.47)5525 (381)797 (55)2800 (193)452 (31)1 1/21.625(41.28)1.621(41.17)1.627(41.33)0.072(1.83)1.360(0.62)5000 (345)742 (51)2600 (179)420 (29)22.125(53.98)2.121(53.87)2.127(54.03)0.083(2.11)2.060(0.93)3915 (270)652 (45)2235 (154)370 (26)2 1/22.625(66.68)2.621(66.57)2.627(66.73)0.095(2.41)2.930(1.33)3575 (246)597 (41)N/AN/A338 (23)33.125(79.38)3.121(79.27)3.127(79.43)0.109(2.77)4.000(1.81)3450 (238)578 (40)N/AN/A328 (23)3 1/23.625(92.08)3.621(91.97)3.627(92.13)0.120(3.05)5.120(2.32)N/AN/A549 (38)N/AN/A311 (21)44.125(104.78)4.121(104.67)4.127(104.83)0.134(3.40)6.510(2.95)3415 (235)540 (37)N/AN/A306 (21)55.125(130.18)5.121(130.07)5.127(130.23)0.160(4.06)9.670(4.39)3585 (247)517 (36)N/AN/A293 (20)66.125(155.58)6.121(155.47)6.127(155.63)0.192(4.88)13.900(6.30)3425 (236)520 (36)N/AN/A295 (20)88.125(206.38)8.119(206.22)8.127(206.43)0.271(6.88)25.900(11.75)3635 (251)553 (38)N/AN/A314 (22)1010.125(257.18)10.119(257.02)10.127(257.23)0.338(8.59)40.300(18.28)N/AN/A553 (38)N/AN/A314 (22)1212.125(307.98)12.119(307.82)12.127(308.03)0.405(10.29)57.800(26.22)N/AN/A555 (38)N/AN/A314 (22)Note: Information and data contained in these charts, as taken from ASTM Specifications B 88. Rated internal pressure for copper water tube based on the strength of the tube alone and applicable to systems using suitable mechanical joints.A Based on actual laboratory test data provided by Copper Development Association, Inc.B Based upon 150°F (65.6°C) with an allowable stress of 9500 psi (668 kPa).C Based upon 150°F (65.6°C) with an allowable stress of 5100 psi (359 kPa). AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 51 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents.DIMENSIONAL DATA – COPPER WATER TUBE – TYPE “L”TYPE “L”Hard Drawn:20-ft. (6.1m) Straight Lengths Soft Annealed:20-ft. (6.1m) Straight Lengths, or 40-ft. (12.2m) and 60-ft. (18.3m) Length Coils (to and including size 1 1/2)Usage:For general purpose plumbing and heating conditions. TolerancesHard DrawnSoft Annealed (Hard Drawn Only)OutsideTubing ODNominal WallWeightBurstingSafe WorkingBurstingSafe Working NominalDiameterThicknessPer FootPressure A Pressure B Pressure A Pressure C Water TubeMin.Max.Size (In Inches)Inch(mm)Inch(mm)Inch(mm)Inch(mm)Lb(kg)psi(bars)psi(bars)psi(bars)psi(bars)1/40.375(9.53)0.373(9.47)0.376(9.55)0.030(0.76)0.126(0.06)N/AN/A1367 (94)N/AN/A775 (53)3/80.500(12.70)0.497(12.62)0.501(12.73)0.035(0.89)0.198(0.09)N/AN/A1168 (81)N/AN/A662 (46)1/20.625(15.88)0.622(15.80)0.626(15.90)0.040(1.02)0.285(0.13)7765 (535)1082 (75)3885 (268)613 (42)5/80.750(19.05)0.747(18.97)0.751(19.08)0.042(1.07)0.362(0.16)N/AN/A947 (65)N/AN/A537 (37)3/40.875(22.23)0.872(22.15)0.876(22.25)0.045(1.14)0.455(0.21)5900 (407)873 (60)2935 (202)495 (34)11.125(28.58)1.122(28.50)1.127(28.63)0.050(1.27)0.655(0.30)5115 (353)741 (51)2650 (183)420 (29)1 1/41.375(34.93)1.372(34.85)1.377(34.98)0.055(1.40)0.884(0.40)4550 (314)658 (45)2400 (165)373 (26)1 1/21.625(41.28)1.621(41.17)1.627(41.33)0.060(1.52)1.140(0.52)4100 (283)613 (42)2200 (152)347 (24)22.125(53.98)2.121(53.87)2.127(54.03)0.070(1.78)1.750(0.79)3365 (232)545 (38)1910 (132)309 (21)2 1/22.625(66.68)2.621(66.57)2.627(66.73)0.080(2.03)2.480(1.12)3215 (222)504 (35)N/AN/A285 (20)33.125(79.38)3.121(79.27)3.127(79.43)0.090(2.29)3.330(1.51)2865 (198)476 (33)N/AN/A270 (19)3 1/23.625(92.08)3.621(91.97)3.627(92.13)0.100(2.54)4.290(1.95)N/AN/A455 (31)N/AN/A258 (18)44.125(104.78)4.121(104.67)4.127(104.83)0.110(2.79)5.380(2.44)2865 (198)440 (30)N/AN/A249 (17)55.125(130.18)5.121(130.07)5.127(130.23)0.125(3.18)7.610(3.45)2985 (206)404 (28)N/AN/A229 (16)66.125(155.58)6.121(155.47)6.127(155.63)0.140(3.56)10.200(4.63)2690 (185)376 (26)N/AN/A213 (15)88.125(206.38)8.119(206.22)8.127(206.43)0.200(5.08)19.290(8.75)2650 (183)406 (28)N/AN/A230 (16)1010.125(257.18)10.119(257.02)10.127(257.23)0.250(6.35)30.100(13.65)N/AN/A407 (28)N/AN/A231 (16)1212.125(307.98)12.119(307.82)12.127(308.03)0.280(7.11)40.400(18.33)N/AN/A380 (26)N/AN/A215 (15)Note: Information and data contained in these charts, as taken from ASTM Specifications B 88. Rated internal pressure for copper water tube based on the strength of the tube alone and applicable to systems using suitable mechanical joints.A Based on actual laboratory test data provided by Copper Development Association, Inc.B Based upon 150°F (65.6°C) with an allowable stress of 9500 psi (668 kPa).C Based upon 150°F (65.6°C) with an allowable stress of 5100 psi (359 kPa). AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 52 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents.Copper Water Tube continued DIMENSIONAL DATA – COPPER WATER TUBE – TYPE “M”TYPE “M”Hard Drawn Only:20-ft. (6.1m) Straight Lengths Usage:For general purpose plumbing, heating and drainage installations.TolerancesHard Drawn (Hard Drawn Only)OutsideTubing ODNominal WallWeightBurstingSafe Working NominalDiameterThicknessPer FootPressure A Pressure B Water TubeMin.Max.Size (In Inches)Inch(mm)Inch(mm)Inch(mm)Inch(mm)Lb(kg)psi(bars)psi(bars)1/40.375(9.53)0.373(9.47)0.376(9.55)N/AN/AN/AN/AN/AN/AN/AN/A 3/80.500(12.70)0.497(12.62)0.501(12.73)0.025(0.64)0.145(0.07)N/AN/A855 (59)1/20.625(15.88)0.622(15.80)0.626(15.90)0.028(0.71)0.204(0.09)6135 (423)741 (51)5/80.750(19.05)0.747(18.97)0.751(19.08)N/AN/AN/AN/AN/AN/AN/AN/A 3/40.875(22.23)0.872(22.15)0.876(22.25)0.032(0.81)0.328(0.15)4717 (325)611 (42)11.125(28.58)1.122(28.50)1.127(28.63)0.035(0.89)0.465(0.21)3865 (266)506 (35)1 1/41.375(34.93)1.372(34.85)1.377(34.98)0.042(1.07)0.682(0.31)3875 (267)507 (35)1 1/21.625(41.28)1.621(41.17)1.627(41.33)0.049(1.24)0.940(0.43)3550 (245)497 (34)22.125(53.98)2.121(53.87)2.127(54.03)0.058(1.47)1.460(0.66)2935 (202)448 (31)2 1/22.625(66.68)2.621(66.57)2.627(66.73)0.065(1.65)2.030(0.92)2800 (193)411 (28)33.125(79.38)3.121(79.27)3.127(79.43)0.072(1.83)2.680(1.22)2665 (184)380 (26)3 1/23.625(92.08)3.621(91.97)3.627(92.13)0.083(2.11)3.580(1.62)N/AN/A378 (26)44.125(104.78)4.121(104.67)4.127(104.83)0.095(2.41)4.660(2.11)2215 (153)377 (26)55.125(130.18)5.121(130.07)5.127(130.23)0.109(2.77)6.660(3.02)2490 (172)349 (24)66.125(155.58)6.121(155.47)6.127(155.63)0.122(3.10)8.920(4.05)2000 (138)328 (23)88.125(206.38)8.119(206.22)8.127(206.43)0.170(4.32)16.500(7.48)2285 (158)344 (24)1010.125(257.18)10.119(257.02)10.127(257.23)0.212(5.38)25.600(11.61)N/AN/A344 (24)1212.125(307.98)12.119(307.82)12.127(308.03)0.254(6.45)36.700(16.65)N/AN/A345 (24)Note: Information and data contained in these charts, as taken from ASTM Specifications B 88. Rated internal pressure for copper water tube based on the strength of the tube alone and applicable to systems using suitable mechanical joints.A Based on actual laboratory test data provided by Copper Development Association, Inc.B Based upon 150°F (65.6°C) with an allowable stress of 9500 psi (668 kPa). AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 53 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents.DIMENSIONAL DATA – COPPER WATER TUBE – TYPE “DWV”TYPE “DWV”Hard Drawn Only:20-ft. (6.1m) Straight Lengths Usage:For drain, waste, vent and other non-pressure applications.TolerancesHard Drawn (Hard Drawn Only)OutsideTubing ODNominal WallWeightBursting NominalDiameterThicknessPer FootPressure A Water TubeMin.Max.Size (In Inches)Inch(mm)Inch(mm)Inch(mm)Inch(mm)Lb(kg)psi(bars)1/40.375(9.53)0.373(9.47)0.376(9.55)N/AN/AN/AN/AN/AN/A 3/80.500(12.70)0.497(12.62)0.501(12.73)N/AN/AN/AN/AN/AN/A 1/20.625(15.88)0.622(15.80)0.626(15.90)N/AN/AN/AN/AN/AN/A 5/80.750(19.05)0.747(18.97)0.751(19.08)N/AN/AN/AN/AN/AN/A 3/40.875(22.23)0.872(22.15)0.876(22.25)N/AN/AN/AN/AN/AN/A 11.125(28.58)1.122(28.50)1.127(28.63)N/AN/AN/AN/AN/AN/A 1 1/41.375(34.93)1.372(34.85)1.377(34.98)0.040(1.02)0.650(0.29)N/AN/A 1 1/21.625(41.28)1.621(41.17)1.627(41.33)0.042(1.07)0.809(0.37)440 (30)22.125(53.98)2.121(53.87)2.127(54.03)0.042(1.07)1.070(0.49)326 (22)2 1/22.625(66.68)2.621(66.57)2.627(66.73)N/AN/AN/AN/AN/AN/A 33.125(79.38)3.121(79.27)3.127(79.43)0.045(1.14)1.690(0.77)239 (16)3 1/23.625(92.08)3.621(91.97)3.627(92.13)N/AN/AN/AN/AN/AN/A 44.125(104.78)4.121(104.67)4.127(104.83)0.058(1.47)2.870(1.30)225 (16)55.125(130.18)5.121(130.07)5.127(130.23)0.072(1.83)4.430(2.01)227 (16)66.125(155.58)6.121(155.47)6.127(155.63)0.083(2.11)6.100(2.77)223 (15)88.125(206.38)8.119(206.22)8.127(206.43)0.109N/A10.600(4.81)219 (15)1010.125(257.18)10.119(257.02)10.127(257.23)N/AN/AN/AN/AN/AN/A 1212.125(307.98)12.119(307.82)12.127(308.03)N/AN/AN/AN/AN/AN/A Note: Information and data contained in these charts, as taken from ASTM Specifications B 88. Rated internal pressure for copper water tube based on the strength of the tube alone and applicable to systems using suitable mechanical joints.A Based on actual laboratory test data provided by Copper Development Association, Inc.B Based upon 150°F (65.6°C) with an allowable stress of 9500 psi (668 kPa).C Based upon 150°F (65.6°C) with an allowable stress of 5100 psi (359 kPa).DWV Tube is for sanitary drainage applications. The tubing wall is thinner than Type “M” – making it both lighter and less expensive. Research indicates that DWV tube has a service life of approximately 100 years –considerably longer than any building in which it might be installed.The advantages of copper systems are augmented in DWV installations. Its light weight makes handling and transportation easier – only 0.34 lb. (0.15 kg) for a 20 ft. (6.1 m) length of size 3. Its thinner wall allows faster soldering.These advantages offer an economical option without sacrificing stability or longevity for both contractor and the home owner. Further information will be furnished on request from NIBCO’s Technical Services Department, at 1-888-446-4226 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 54 Copper Water Tube continued Under normal conditions, the physical properties of copper tubes, when produced by responsible manufacturers are perfectly adap ted for the conveyance of hot and cold water, steam, oil, gas, and air. Copper tubes will stand up under ordinary conditions, but t he user is specifically cautioned against laying underground tube in cinderfill, especially if the ground is apt to be wet. Due to the sul phur compounds in the cinders, a condition of this kind may corrode the outside of the tubes. This may be overcome either by wrappin g the tube with canvas and asphaltum or by surrounding the tube with a bed of clean sand mixed with lime, or with limestone or broken plaster. When conditions are doubtful, it is advisable to consult the Copper Development Association, or the tube manufacturer.Annealed copper tubes are generally recommended for underground use. 1 /2 " annealed copper tubes have been frozen as many as six times before finally bursting, eight times for 1" size, and eleven times for 2" size. Hard drawn copper tubes, however, burst d uring the first freezing the same as iron pipe. (Condensed from Copper Tube Handbook.)COMPARATIVE DATA – COPPER WATER TUBE AND IRON PIPES BTUs to Raise 100°F/38°C Nominal“A”“B”“C”“D”“E”“F”“G”“H”“I”WaterNew PipeInside OutsideWeightVolumeWaterPipeHeat LossFlow Tube Size DiameterDiameter (In Inches)Inch(mm)Inch(mm)Lb(Kg)Gal/10ft.L/3.05m BTUkJBTUkJBTUkJGPMLPM 3/8Coper.430(10.92)0.500(12.70)0.198(0.090)0.0754(0.2854)62.89(66.4)18.61(19.6)No DataNo Data1.873(7.089)Iron.493(12.52)0.675(17.15)0.567(0.257)0.0992(0.3755)82.66(87.2)62.37(65.8)No DataNo Data2.464(9.326)1/2Coper.545(13.84)0.625(15.88)0.285(0.129)0.1212(0.4587)101.20(106.8)26.70(28.2)0.34(0.36)3.565(13.494)Iron.622(15.80)0.840(21.34)0.850(0.386)0.1578(0.5973)131.60(138.8)93.50(98.6)5.94(6.27)4.585(17.354)3/4Coper.785(19.94)0.875(22.23)0.455(0.207)0.2514(0.9515)209.60(221.1)42.67(45.0)0.41(0.44)9.599(36.332)Iron.824(20.93)1.050(26.67)1.130(0.513)0.2770(1.0484)230.10(242.8)124.30(131.1)7.16(7.55)9.720(36.790)1Coper1.025(26.04)1.125(28.58)0.655(0.297)0.4287(1.6226)357.30(377.0)61.38(64.8)0.50(0.53)19.80(74.94)Iron1.049(26.64)1.315(33.40)1.678(0.762)0.4490(1.6995)374.30(394.9)184.58(194.7)8.62(9.09)18.53(70.14)1 1/4Coper1.265(32.13)1.375(34.93)0.884(0.401)0.6529(2.4712)544.30(574.3)82.91(87.5)0.62(0.65)35.05(132.66)Iron1.380(35.05)1.660(42.16)2.270(1.031)0.7770(2.9409)647.70(683.4)249.70(263.4)10.65(11.24)38.56(145.95)1 1/2Coper1.505(38.23)1.625(41.28)1.140(0.518)0.9241(3.4977)770.40(812.8)107.16(113.1)0.69(0.73)56.16(212.57)Iron1.610(40.89)1.900(48.26)2.720(1.235)1.0580(4.0045)881.60(930.1)298.10(314.5)11.97(12.63)58.20(220.29)2Coper1.985(50.42)2.125(53.98)1.750(0.795)1.6080(6.0863)1340.00(1413.8)164.50(173.6)0.84(0.89)119.10(450.79)Iron2.067(52.50)2.375(60.33)3.650(1.657)1.7430(6.5973)1453.00(1533.0)401.50(423.6)14.61(15.41)113.50(429.60)2 1/2Coper2.465(62.61)2.625(66.68)2.480(1.126)2.4790(9.3830)2066.00(2179.7)233.00(245.8)1.01(1.07)214.30(811.13)Iron2.469(62.71)2.875(73.03)5.790(2.629)2.4870(9.4133)2073.00(2187.1)636.90(672.0)17.42(18.38)182.50(690.76)3Coper2.945(74.80)3.125(79.38)3.330(1.512)3.5390(13.3951)2945.00(3107.1)313.20(330.4)1.13(1.19)347.40(1314.91)Iron3.068(77.93)3.5(88.90)7.58(3.441)3.8400(14.5344)3201.00(3377.2)832.70(878.5)20.63(21.77)326.00(1233.91)4Coper3.905(99.19)4.125(104.78)5.380(2.443)6.2220(23.5503)5186.00(5471.5)505.72(533.6)1.50(1.58)747.10(2827.77)Iron4.026(102.26)4.5(114.30)10.79(4.899)6.6130(25.0302)5513.00(5816.5)1186.90(1252.2)26.00(27.43)673.80(2550.33)COLUMN A: The copper tube is Type L Standard, meeting the requirements of ASTM Specification B 88. The iron pipe is standard weight, schedule 40, bare pipe, except as to Column I where new galvanized pipe is referred to.COLUMN B: From manufacturers’ specifications. Slight variations can be noted between specifications of different manufacturers, but these figures are representative.COLUMN C: From manufacturers’ specifications with the same considerations as noted for Column B.COLUMN D: From manufacturers’ specifications.COLUMN E: Cubic contents of 10 linear feet/3.05 linear metres of tube and have been calculated from dimeters given in Column B, by the formula for the contents of a cylinder.COLUMN F: This column has been calculated from Column E and shows the number of BTUs (kilojoules) required to heat the water content only of 10 feet (3.05 metres) of the given tube and pipe 100°F (38°C). It requires 833.6 BTUs (879.5 kJ) to heat 1 gallon (3.875 litres) of water 100°F (38°C).COLUMN G: These figures are calculated from Column D and show the number of BTUs (kJ) required to raise the temperature of 10 feet (3.05 metres) of empty tube and pipe 100°F (38°C). Due to difference in the specific heat of the materials, it requires 9.4 BTUs (9.9 kJ) to raise 1 pound (0.454 kilograms) of copper 100°F (38°C) and 11.0 BTUs (11.6 kJ) to raise 1 pound (0.454 kilograms) of iron 100°F (38°C).COLUMN H: This column shows the heat emission from 10 feet (3.05 metres) of the given tube and pipe placed horizontally. The column in terms of BTUs lost per hour (kilojoules lost per hour) for each degree of difference in temperature between the pipe and the surrounding air. The figures for iron are taken from experimental data obtained at the Mellon Institute. Figures for copper have been calculated with reference to those for iron on the basis of the known ratio of heat emission between the two materials.COLUMN I: This column shows the number of gallons (litres) of water which will flow through 100 feet (30.48 metres) of the given tube and pipe with a pressure loss of 10 pounds per square inch (70 kilopascals). Flow is based on diameters in Column B according to Professor Dawson’s formulae for NEW galvanized iron pipe and NEW copper tube. Due to the corrosion of iron and its tendency to accumulate sediments and other foreign matter, Prof. Dawson suggests that 15% be deducted from the figures for iron pipe in order to arrive at a reasonable performance expectancy for such pipe in service. Because copper resists rust and is inherently more smooth, Professor Dawson suggests a deduction of only 5% from the figures given for copper tube.U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. RADII OF COILED EXPANSION LOOPS AND DEVELOPED LENGTHS OF EXPANSION OFFSETS Expected Expansion Nominal 1/211 1/222 1/233 1/24 TubeRLRLRLRLRLRLRLRL Size Inch(mm)Inch(mm)Inch(mm)Inch(mm)Inch(mm)Inch(mm)Inch(mm)Inch(mm)Inch(mm)1/4 6(152.4)38(965.2)9(228.6)54(1371.6)11(279.4)66(1676.4)12(304.8)77(1955.8)14(355.6)3/8 7(177.8)44(1117.6)10(254.0)63(1600.2)12(304.8)77(1955.8)14(355.6)89(2260.6)16(406.4)1/2 8(203.2)50(1270.0)11(279.4)70(1778.0)14(355.6)89(2260.6)16(406.4)99(2514.6)18(457.2)3/4 9(228.6)59(1498.6)13(330.2)83(2108.2)16(406.4)101(2565.4)19(482.6)117(2971.8)21(533.4)1 11(279.4)67(1701.8)15(381.0)94(2387.6)18(457.2)115(2921.0)21(533.4)133(3378.2)24(609.6)1 1/2 13(330.2)80(2032.0)18(457.2)113(2870.2)22(558.8)138(3505.2)25(635.0)160(4064.0)29(736.6)2 15(381.0)91(2311.4)21(533.4)129(3276.6)25(635.0)158(4013.2)29(736.6)183(4648.2)33(838.2)2 1/2 16(406.4)102(2590.8)23(584.2)144(3657.6)28(711.2)176(4470.4)32(812.8)203(5156.2)36(914.4)3 18(457.2)111(2819.4)25(635.0)157(3987.8)30(762.0)191(4851.4)35(889.0)222(5638.8)40(1016.0)3 1/2 19(482.6)120(3048.0)27(685.8)169(4292.6)33(838.2)206(5232.4)38(965.2)239(6070.6)43(1092.2)4 20(508.0)128(3251.2)29(736.6)180(4572.0)35(889.0)220(5588.0)41(1041.4)255(6477.0)45(1143.0)5 23(584.2)142(3606.8)32(812.8)201(5105.4)39(990.6)245(6223.0)45(1143.0)284(7213.6)51(1295.4)Inch(mm)Inch(mm)Inch(mm)Inch(mm)Inch(mm)Inch(mm)Inch(mm)86(2184.4)15(381.0)94(2387.6)16(406.4)102(2590.8)17(431.8)109(2768.6)99(2514.6)17(431.8)109(2768.6)19(482.6)117(2971.8)20(508.0)126(3200.4)111(2819.4)19(482.6)122(3098.8)21(533.4)131(3327.4)22(558.8)140(3556.0)131(3327.4)23(584.2)143(3632.2)25(635.0)155(3937.0)26(660.4)166(4216.4)149(3784.6)26(660.4)163(4140.2)28(711.2)176(4470.4)30(762.0)188(4775.2)179(4546.6)31(787.4)196(4978.4)34(863.6)212(5384.8)36(914.4)226(5740.4)205(5207.0)36(914.4)224(5689.6)39(990.6)242(6146.8)41(1041.4)259(6578.6)227(5765.8)40(1016.0)249(6324.6)43(1092.2)269(6832.6)46(1168.4)288(7315.2)248(6299.2)43(1092.2)272(6908.8)47(1193.8)293(7442.2)50(1270.0)314(7975.6)267(6781.8)47(1193.8)293(7442.2)50(1270.0)316(8026.4)54(1371.6)338(8585.2)285(7239.0)50(1270.0)312(7924.8)54(1371.6)337(8559.8)57(1447.8)361(9169.4)318(8077.2)55(1397.0)348(8839.2)60(1524.0)376(9550.4)64(1625.6)402(10210.8)AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 55 In the majority of low-pressure heating systems employing copper tube and installed in small houses or private dwellings, provision for expansion and contraction is relatively simple. Mains, risers, and branches to radiators should be free or floating at one end of the line. Holes should be large enough to permit free movement of the tube, and care should be exercised so that pipe hangers and supports permit unrestricted movement and do not anchor the tube.Wrought copper tube hangers that are both practicable and neat in appearance are available.Unusually long runs of copper tubing should be provided with an expansion bend or loop. By bending soft temper copper tube, a simple form of expansion loop can be made. With the addition of combination flared-tube to solder joint fittings, as illustrated in Figure 1, these types of loops can be used when space or other limitations exist. The correct proportions of such expansion loop to meet various conditions are shown in the accompanying table.FIGURE 1 EXPANSION AND CONTRACTION U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents.The above chart is calculated using 10ft (3.05m) of copper tubing as the reference point. You may use it as follows: 100ft (30.5m) of copper tube, with a 200°F (93.3°C) temperature change. Reference point .2256 inches for 10ft, (5.73mm for 3.05m), multipy by 10 for 100ft (30.5m), resulting in an answer of 2.256 inches (57.3mm) of expansion or contraction.NOTE: Calculations for expansion and contraction should be based on the average coefficient of expansion of copper which is 0.0000094 per °F (0.00001692 per °C) between 77°F and 212°F (25°C and 100°C). For example, the expansion for each 10ft (3.05m)of any size of tube heated from room temperature of 70°F (21.1°C) to 170°F (76.7°C), that is, 100°F (55.6°C) rise, is:RiseCoefficient 100°F10ft12 inches0.0000940.1128 in.xxx=(55.6°C)(3.05m)(1000mm)(0.00001692)(2.87mm)a. U-Bend c. Offset and Return b. Coiled Loop APPROXIMATE FRICTION LOSS ALLOWANCES FOR FITTINGS AND VALVES IN FEET OF STRAIGHT TUBE Wrought-Copper FittingsCast Copper Alloy Fittings and Valves Nominal90°45°Tee Tee 90°180°90°45°TeeTee Comp.GlobeGate Tube Size ElbowElbowRunSide OutletBendBendElbowElbowRunSide OutletStopValveValve (In Inches)Feet(m)Feet(m)Feet(m)Feet(m)Feet(m)Feet(m)Feet(m)Feet(m)Feet(m)3/8 0.5(0.15)0.5(0.15)0.5(0.15)1(0.31)0.5(0.15)0.5(0.15)1(0.31)0.5(0.15)0.5(0.15)1/2 0.5(0.15)0.5(0.15)0.5(0.15)1(0.31)0.5(0.15)1(0.31)1(0.31)0.5(0.15)0.5(0.15)5/8 0.5(0.15)0.5(0.15)0.5(0.15)2(0.61)1(0.31)1(0.31)2(0.61)1(0.31)0.5(0.15)3/4 1(0.31)0.5(0.15)0.5(0.15)2(0.61)1(0.31)2(0.61)2(0.61)1(0.31)0.5(0.15)1 1(0.31)1(0.31)0.5(0.15)3(0.92)2(0.61)2(0.61)4(1.22)2(0.61)0.5(0.15)1 1/4 2(0.61)1(0.31)0.5(0.15)4(1.22)2(0.61)3(0.92)5(1.53)2(0.61)1(0.31)1 1/2 2(0.61)2(0.61)1(0.31)5(1.53)2(0.61)4(1.22)8(2.44)3(0.92)1(0.31)2 2(0.61)2(0.61)1(0.31)7(2.14)3(0.92)8(2.44)11(3.36)5(1.53)2(0.61)2 1/2 2(0.61)3(0.92)2(0.61)9(2.75)4(1.22)16(4.88)14(4.27)8(2.44)2(0.61)3 3(0.92)4(1.22)––––5(1.53)20(6.10)18(5.49)11(3.36)2(0.61)3 1/2 4(1.22)––––––7(2.14)24(7.32)24(7.32)14(4.27)2(0.61)4 ––––––––8(2.44)28(8.54)28(8.54)17(5.19)2(0.61)5 ––––––––10(3.05)37(11.29)41(12.51)22(6.71)2(0.61)6 ––––––––13(3.97)47(14.34)52(15.86)28(8.54)2(0.61)Notes: This table is based on tests conducted at Harvard University (1948).If the type of fitting is not known – i.e., whether wrought copper or cast alloy – use cast copper alloy values for design.Feet(m)Feet(m)Feet(m)Feet(m)2(0.61)9(2.75)––––2(0.61)13(3.97)––––3(0.92)17(5.19)––––3(0.92)21(6.41)––––5(1.53)30(9.15)––1(0.31)7(2.14)––53(16.17)1(0.31)9(2.75)––66(20.13)2(0.61)12(3.66)––90(27.45)2(0.61)16(4.88)––––2(0.61)20(6.10)––––2(0.61)31(9.46)––––2(0.61)37(11.29)––––2(0.61)48(14.64)––––––61(18.61)––––––AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 56 SELECTION OF TUBE SIZES The smooth interior of copper tube, and the design of both solder joint and flared-tube-type fittings, which have no shoulders projecting into the flow of water, decrease friction loss. With the use of copper tube, no allowance is necessary for the accumulation of rust deposits in supply and service lines. Consequently, copper tube lines are usually figured one size smaller than iron pipe for the same service. Th is rule does not apply to lines from a well to a pump where the nominal diameters specified by the pump manufacturer must be adhered to strictly .Water passing through any pipe line encounters resistance by friction. The resistance is increased by bends and turns in the li ne, which should be taken into account in complex piping systems. For example, a one-inch 90° elbow will cause friction loss equivalent to that of one foot (0.305m) of straight one-inch tube. (See below for allowance to be made for fittings and valves in equivalent lengths of tube.) Friction loss in terms of head loss must be taken into consideration in calculating tube sizes to be used for various types of installations.For most average-size-house installations with water pressures 40 PSI (275.8kPa) and higher, 3 /4 " copper tube will be ample for main supply lines, and 1 /2 " copper tube can be used for risers and branches to all fixtures. The smaller 3 /8 " tube is adequate to supply branches, but with pressures at 40 PSI (275.8kPa) and higher, water hammer becomes a concern when the flow is suddenly stopped.Copper Water Tube continued U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 57 COPPER WATER TUBE – INTERNAL WORKING PRESSURES*Service Temperature °F (°C)100°F (37.8°C) 200°F (93.3°C)300°F (148.9°C)400°F (204.4°C)NominalS = 6000psi (414 bars)S = 4800psi (331 bars)S=4700 psi (324 bars)S=3000 psi (207 bars)Tube Size (In Inches)Type KType LType MType KType LType MType KType LType KType L 1/4 1210(83.43)1025(70.67)––850(58.61)700(48.27)––830(57.23)690(47.58)530(36.54)3/8 1275(87.91)890(61.37)625(43.09)930(64.12)630(43.44)460(31.72)910(62.74)610(42.06)590(40.68)1/2 1005(69.29)810(55.85)560(38.61)730(50.33)580(39.99)415(28.61)720(49.64)570(39.30)460(31.72)5/8 830(57.23)705(48.61)––600(41.37)500(34.48)––580(39.99)500(34.48)380(26.20)3/4 950(65.50)645(44.47)450(31.03)700(48.27)470(32.41)325(22.41)690(47.58)460(31.72)440(30.34)1 725(49.99)550(37.92)380(26.20)540(37.23)400(27.58)270(18.62)530(36.54)400(27.58)340(23.44)1 1/4 590(40.68)495(34.13)375(25.86)440(30.34)370(25.51)270(18.62)430(29.65)360(24.82)280(19.31)1 1/2 550(37.92)455(31.37)370(25.51)410(28.27)340(23.44)270(18.62)400(27.58)330(22.75)260(17.93)2 485(33.44)405(27.92)335(23.10)350(24.13)310(21.37)240(16.55)345(23.79)305(21.03)230(15.86)2 1/2 450(31.03)375(25.86)305(21.03)330(22.75)275(18.96)220(15.17)320(22.06)270(18.62)210(14.48)3 430(29.65)355(24.48)280(19.31)320(22.06)260(17.93)205(14.13)315(21.72)255(17.58)210(14.48)3 1/2 410(28.27)340(23.44)280(19.31)300(20.69)250(17.24)200(13.79)300(20.69)245(16.89)190(13.10)4 400(27.58)325(22.41)280(19.31)295(20.34)240(16.55)200(13.79)290(20.00)235(16.20)190(13.10)5 385(26.55)300(20.69)260(17.93)290(20.00)220(15.17)190(13.10)280(19.31)215(14.82)180(12.41)6 385(26.55)280(19.31)240(16.55)280(19.31)205(14.13)180(12.41)280(19.31)200(13.79)190(13.10)8 410(28.27)300(20.69)255(17.58)300(20.69)220(15.17)190(13.10)300(20.69)215(14.82)200(13.79)10 410(28.27)300(20.69)255(17.58)310(21.37)225(15.51)190(13.10)305(21.03)220(15.17)200(13.79)12 410(28.27)280(19.31)225(15.51)310(21.37)210(14.48)190(13.10)305(21.03)205(14.13)200(13.79)*Rated internal pressures for Copper Water Tube based on the strength of the tube alone and applicable to systems using suitable mechanical joints.The values are based on the formula in the American Standard Code, Power Piping ANSI/ASME B31.1 1992.Formulas 450(31.03)400(27.58)370(25.51)330(22.75)300(20.69)260(17.93)230(15.86)220(15.17)190(13.10)180(12.41)170(11.72)160(11.03)150(10.34)140(9.65)130(8.96)140(9.65)150(10.34)140(9.65)PD tm = + C 2S + 0.8P or 2 S tm P =when C is O D - 0.8 tm tmMinimum tube wall thickness PMaximum rated internal working pressure DOutside diameter of tube SAllowable stress in material due to internal pressure at operating temperature CAllowance for threading, mechanical strength and/or corrosion U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 58 1/4" TYPE “K” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=0.3760 inches (9.550 mm)Nominal O.D.=0.3750 inches (9.525 mm)Minimum O.D.=0.3740 inches (9.499 mm)Nominal I.D.=0.3050 inches (7.747 mm)Nominal Wall Thickness=0.0350 inches (0.089 mm)Flow Area=0.0731 sq. inches (47.14 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)0.503.778.812.20320.858.810.67 1.0013.6231.774.39633.0831.771.34 1.5028.8667.276.59956.5367.272.01 2.0049.17114.548.7812611.12114.542.68 2.5074.33173.0810.9815816.81173.083.35 3.00104.18242.5113.1718923.57242.514.02 3.50138.60322.5415.3722131.35322.544.68 4.00177.49412.9217.5725240.15412.925.35 4.50220.75513.4619.7628449.94513.466.02 5.00268.32623.9621.9631560.70623.966.69 1/4" TYPE “L” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=0.3760 inches (9.550 mm)Nominal O.D.=0.3750 inches (9.525 mm)Minimum O.D.=0.3740 inches (9.499 mm)Nominal I.D.=0.3150 inches (8.001 mm)Nominal Wall Thickness=0.0300 inches (0.076 mm)Flow Area=0.0779 sq. inches (50.28 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)0.503.227.532.06320.737.530.63 1.0011.6427.164.12632.6327.161.25 1.5024.6757.506.18955.5857.501.88 2.0042.0297.908.231269.5197.902.51 2.5063.53147.9410.2915814.37147.943.14 3.0089.05207.2812.3518920.14207.283.76 3.50118.47275.6914.4122126.80275.694.39 4.00151.71352.9416.4725234.32352.945.02 4.50188.68438.8718.5328442.68438.875.65 5.00229.34533.3220.5831551.88533.326.27 3/8" TYPE “K” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=0.5010 inches (12.725 mm)Nominal O.D.=0.5000 inches (12.700 mm)Minimum O.D.=0.4990 inches (12.674 mm)Nominal I.D.=0.4020 inches (10.210 mm)Nominal Wall Thickness=0.0490 inches (1.244 mm)Flow Area=0.1269 sq. inches (81.89 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)1.003.558.292.53630.808.290.77 1.507.5317.553.79951.7017.551.16 2.0012.8329.895.061262.9029.891.54 2.5019.3945.166.321584.3945.161.93 3.0027.1863.287.581896.1563.282.31 3.5036.1684.168.852218.1884.162.70 4.0046.31107.7410.1125210.48107.743.08 4.5057.60133.9711.3728413.03133.973.47 5.0070.01162.8012.6431515.84162.803.85 5.5083.52194.1913.9034718.89194.194.24 6.0098.13228.1115.1737922.20228.114.62 6.50113.81264.5116.4341025.74264.515.01 7.00130.55303.3817.6944229.53303.385.39 7.50148.34344.6818.9647333.56344.685.78 8.00167.18388.4020.2250537.82388.406.16 8.50187.04434.4921.4953642.31434.496.55 9.00207.93482.9622.7556847.03482.966.93 9.50229.83533.7624.0159951.99533.767.32 10.00252.73586.8925.2863157.17586.897.70 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. 3/8" TYPE “L” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=0.5010 inches (12.725 mm)Nominal O.D.=0.5000 inches (12.700 mm)Minimum O.D.=0.4990 inches (12.675 mm)Nominal I.D.=0.4500 inches (10.211 mm)Nominal Wall Thickness=0.0350 inches (0.889 mm)Flow Area=0.1590 sq. inches (102.61 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)1.002.565.972.21630.585.970.67 1.505.4312.653.31951.2312.651.01 2.009.2421.544.421262.0921.541.35 2.5013.9832.545.521583.1632.541.68 3.0019.5945.606.631894.4345.602.02 3.5026.0660.657.732215.9060.652.36 4.0033.3777.648.842527.5577.642.69 4.5041.5196.549.942849.3996.543.03 5.0050.45117.3211.0531511.41117.323.37 5.5060.19139.9412.1534713.62139.943.70 6.0070.72164.3813.2637916.00164.384.04 6.5082.01190.6214.3641018.55190.624.38 7.0094.08218.6315.4644221.28218.634.71 7.50106.90248.4016.5747324.18248.405.05 8.00120.48279.9017.6750527.25279.905.39 8.50134.79313.1218.7853630.49313.125.72 9.00149.84348.0419.8856833.90348.046.06 9.50165.62384.6520.9959937.47384.656.40 10.00182.13422.9422.0963141.20422.946.73 3/8" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=0.5010 inches (12.725 mm)Nominal O.D.=0.5000 inches (12.700 mm)Minimum O.D.=0.4990 inches (12.675 mm)Nominal I.D.=0.4020 inches (10.211 mm)Nominal Wall Thickness=0.0250 inches (0.635 mm)Flow Area=0.1269 sq. inches (81.89 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)1.002.054.792.02630.464.790.61 1.504.3510.143.03950.9810.140.92 2.007.4117.264.031261.6817.261.23 2.5011.2026.095.041582.5326.091.54 3.0015.7036.556.051893.5536.551.84 3.5020.8948.617.062214.7348.612.15 4.0026.7562.238.072526.0562.232.46 4.5033.2777.399.082847.5377.392.77 5.0040.4494.0410.093159.1594.043.07 5.5048.25112.1711.0934710.91112.173.38 6.0056.68131.7612.1037912.82131.763.69 6.5065.74152.7913.1141014.87152.794.00 7.0075.41175.2514.1244217.06175.254.30 7.5085.69199.1015.1347319.38199.104.61 8.0096.57224.3516.1450521.84224.354.92 8.50108.04250.9817.1553624.44250.985.23 9.00120.11278.9718.1656827.17278.975.53 9.50132.76308.3219.1659930.03308.325.84 10.00145.99339.0120.1763133.02339.016.15 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 59 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 60 1/2" TYPE “K” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=0.626 inches (15.900 mm)Nominal O.D.=0.6250 inches (15.875 mm)Minimum O.D.=0.624 inches (15.850 mm)Nominal I.D.=0.527 inches (13.3858 mm)Nominal Wall Thickness=0.049 inches (1.245 mm)Flow Area=0.2181 sq. inches (140.73 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)1.000.952.221.47630.222.220.45 1.502.024.702.21950.464.700.67 2.003.448.002.941260.788.000.90 2.505.1912.103.681581.1812.101.12 3.007.2816.954.411891.6516.951.34 3.509.6922.545.152212.1922.541.57 4.0012.4028.865.882522.8128.861.79 4.5015.4335.886.622843.4935.882.02 5.0018.7543.617.353154.2443.612.24 5.5022.3752.018.093475.0652.012.47 6.0026.2861.108.833795.9561.102.69 6.5030.4870.859.564106.9070.852.91 7.0034.9781.2610.304427.9181.263.14 7.5039.7392.3211.034738.9992.323.36 8.0044.78104.0311.7750510.13104.033.59 8.5050.10116.3812.5053611.33116.383.81 9.0055.69129.3613.2456812.60129.364.03 9.5061.56142.9713.9759913.93142.974.26 10.0067.69157.2014.7163115.31157.204.48 10.5074.10172.0515.4466216.76172.054.71 11.0080.76187.5116.1869418.27187.514.93 11.5087.69203.5816.9172519.84203.585.16 12.0094.88220.2617.6575721.46220.265.38 12.50102.34237.5418.3978923.15237.545.60 13.00110.05255.4119.1282024.89255.415.83 13.50118.01273.8919.8685226.70273.896.05 14.00126.23292.9520.5988328.56292.956.28 1/2" TYPE “L” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=0.626 inches (15.900 mm)Nominal O.D.=0.6250 inches (15.875 mm)Minimum O.D.=0.624 inches (15.850 mm)Nominal I.D.=0.5450 inches (13.843 mm)Nominal Wall Thickness=0.049 inches (1.245 mm)Flow Area=0.2333 sq. inches (150.50 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)1.000.811.891.38630.181.890.42 1.501.713.992.06950.393.990.63 2.002.926.802.751260.666.800.84 2.504.4110.273.441581.0010.271.05 3.006.1814.394.131891.4014.391.26 3.508.2319.144.812211.8619.141.47 4.0010.5324.515.502522.3824.511.68 4.5013.1030.476.192842.9630.471.89 5.0015.9237.036.883153.6037.032.10 5.5019.0044.177.563474.3044.172.31 6.0022.3251.898.253795.0551.892.52 6.5025.8960.178.944105.8660.172.72 7.0029.7069.019.634426.7269.012.93 7.5033.7478.4110.314737.6378.413.14 8.0038.0388.3511.005058.6088.353.35 8.5042.5598.8311.695369.6298.833.56 9.0047.30109.8612.3856810.70109.863.77 9.5052.28121.4113.0759911.83121.413.98 10.0057.49133.5013.7563113.00133.504.19 10.5062.92146.1114.4466214.23146.114.40 11.0068.59159.2415.1369415.51159.244.61 11.5074.47172.8915.8272516.85172.894.82 12.0080.58187.0516.5075718.23187.055.03 12.5086.91201.7317.1978919.66201.735.24 13.0093.46216.9117.8882021.14216.915.45 13.50100.22232.6018.5785222.67232.605.66 14.00107.20248.7819.2588324.25248.785.87 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 61 1/2" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=0.626 inches (15.900 mm)Nominal O.D.=0.6250 inches (15.875 mm)Minimum O.D.=0.624 inches (15.850 mm)Nominal I.D.=0.5690 inches (14.4526 mm)Nominal Wall Thickness=0.028 inches (0.711 mm)Flow Area=0.2543 sq. inches (164.05 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)1.000.661.531.26630.151.530.38 1.501.393.241.89950.313.240.58 2.002.375.512.521260.545.510.77 2.503.588.333.151580.818.330.96 3.005.0111.673.791891.1311.671.15 3.506.6715.524.422211.5115.521.35 4.008.5419.875.052521.9319.871.54 4.5010.6224.715.682842.4024.711.73 5.0012.9130.036.313152.9230.031.92 5.5015.4135.826.943473.4835.822.12 6.0018.1042.077.573794.0942.072.31 6.5020.9948.798.204104.7548.792.50 7.0024.0855.968.834425.4555.962.69 7.5027.3663.579.464736.1963.572.88 8.0030.8371.6410.095056.9871.643.08 8.5034.5080.1410.725367.8080.143.27 9.0038.3589.0811.365688.6889.083.46 9.5042.3998.4511.995999.5998.453.65 10.0046.61108.2512.6263110.54108.253.85 10.5051.02118.4713.2566211.54118.474.04 11.0055.61129.1213.8869412.58129.124.23 11.5060.39140.1914.5172513.66140.194.42 12.0065.34151.6715.1475714.78151.674.61 12.5070.47163.5715.7778915.94163.574.81 13.0075.78175.8816.4082017.14175.885.00 13.5081.26188.6017.0385218.38188.605.19 14.0086.93201.7217.6688319.66201.725.38 5/8" TYPE “K” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=0.751 inches (19.075 mm)Nominal O.D.=0.7500 inches (19.050 mm)Minimum O.D.=0.749 inches (19.025 mm)Nominal I.D.=0.6520 inches (16.5608 mm)Nominal Wall Thickness=0.049 inches (1.245 mm)Flow Area=0.3339 sq. inches (215.40 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)1.000.340.790.96630.080.790.29 2.001.222.841.921260.282.840.59 3.002.586.022.881890.586.020.88 4.004.4010.243.842521.0010.241.17 5.006.6615.484.803151.5115.481.46 6.009.3321.695.773792.1121.691.76 7.0012.4128.856.734422.8128.852.05 8.0015.9036.937.695053.6036.932.34 9.0019.7745.928.655684.4745.922.64 10.0024.0355.819.616315.4455.812.93 11.0028.6766.5710.576946.4966.573.22 12.0033.6978.2011.537577.6278.203.51 13.0039.0790.6812.498208.8490.683.81 14.0044.82104.0013.4588310.14104.004.10 15.0050.92118.1614.4194611.52118.164.39 16.0057.39133.1415.37100912.98133.144.69 17.0064.21148.9516.34107214.52148.954.98 18.0071.38165.5617.30113616.15165.565.27 19.0078.89182.9818.26119917.85182.985.56 20.0086.76201.1919.22126219.63201.195.86 21.0094.96220.1920.18132521.48220.196.15 22.00103.51239.9821.14138823.41239.986.44 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 62 5/8" TYPE “L” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=0.751 inches (19.075 mm)Nominal O.D.=0.7500 inches (19.050 mm)Minimum O.D.=0.749 inches (19.025 mm)Nominal I.D.=0.6660 inches (16.9164 mm)Nominal Wall Thickness=0.042 inches (1.067 mm)Flow Area=0.3484 sq. inches (224.75 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)1.000.300.710.92630.070.710.28 2.001.102.561.841260.252.560.56 3.002.335.432.761890.535.430.84 4.003.979.243.682520.909.241.12 5.006.0013.964.603151.3613.961.40 6.008.4119.565.533791.9019.561.68 7.0011.2026.026.454422.5326.021.96 8.0014.3433.317.375053.2433.312.25 9.0017.8341.418.295684.0341.412.53 10.0021.6750.339.216314.9050.332.81 11.0025.8660.0310.136945.8560.033.09 12.0030.3870.5211.057576.8770.523.37 13.0035.2381.7711.978207.9781.773.65 14.0040.4193.7912.898839.1493.793.93 15.0045.92106.5613.8194610.39106.564.21 16.0051.75120.0714.74100911.71120.074.49 17.0057.90134.3215.66107213.10134.324.77 18.0064.37149.3016.58113614.56149.305.05 19.0071.15165.0117.50119916.09165.015.33 20.0078.24181.4318.42126217.70181.435.61 21.0085.64198.5719.34132519.37198.575.89 22.0093.34216.4220.26138821.11216.426.18 3/4" TYPE “K” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=0.876 inches (22.250 mm)Nominal O.D.=0.8750 inches (22.225 mm)Minimum O.D.=0.874 inches (22.200 mm)Nominal I.D.=0.7450 inches (18.923 mm)Nominal Wall Thickness=0.065 inches (1.651 mm)Flow Area=0.4359 sq. inches (281.24 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)2.000.641.491.471260.141.490.45 4.002.305.352.942520.525.350.90 6.004.8811.344.423791.1011.341.35 8.008.3119.305.895051.8819.301.79 10.0012.5629.177.366312.8429.172.24 12.0017.6140.878.837573.9840.872.69 14.0023.4254.3610.308835.3054.363.14 16.0030.0069.5911.7810096.7969.593.59 18.0037.3186.5413.2511368.4486.544.04 20.0045.35105.1614.72126210.26105.164.49 22.0054.10125.4416.19138812.24125.444.94 24.0063.56147.3417.66151414.38147.345.38 26.0073.72170.8619.14164016.68170.865.83 28.0084.56195.9720.61176619.13195.976.28 30.0096.09222.6522.08189321.74222.656.73 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 63 3/4" TYPE “L” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=0.876 inches (22.250 mm)Nominal O.D.=0.8750 inches (22.225 mm)Minimum O.D.=0.874 inches (22.200 mm)Nominal I.D.=0.7850 inches (19.939 mm)Nominal Wall Thickness=0.045 inches (1.143 mm)Flow Area=0.4840 sq. inches (312.25 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)2.000.49441.15171.3258126.170.11181.15170.4041 4.001.78464.15192.6516252.350.40374.15190.8082 6.003.78158.79053.9774378.520.85548.79051.2123 8.006.442514.96755.3032504.691.457314.96751.6164 10.009.739322.61696.6290630.872.203122.61692.0205 12.0013.651331.68967.9548757.043.088031.68962.4246 14.0018.161842.14729.2806883.214.108342.14722.8287 16.0023.257353.957810.60641009.395.261053.95783.2328 18.0028.926467.094411.93221135.566.543467.09443.6369 20.0035.159081.533813.25801261.737.953281.53384.0411 22.0041.946597.255514.58381387.919.488697.25554.4452 24.0049.2811114.241215.90961514.0811.1477114.24124.8493 26.0057.1557132.474717.23541640.2512.9290132.47475.2534 28.0065.5641151.940818.56131766.4314.8311151.94085.6575 30.0074.5002172.626119.88711892.6016.8525172.62616.0616 3/4" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=0.876 inches (22.250 mm)Nominal O.D.=0.8750 inches (22.225 mm)Minimum O.D.=0.874 inches (22.200 mm)Nominal I.D.=0.8110 inches (20.5994 mm)Nominal Wall Thickness=0.032 inches (0.813 mm)Flow Area=0.5156 sq. inches (333.27 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)2.000.420.981.241260.100.980.38 4.001.523.542.482520.343.540.76 6.003.237.503.733790.737.501.14 8.005.5012.774.975051.2412.771.51 10.008.3119.306.216311.8819.301.89 12.0011.6527.047.457572.6427.042.27 14.0015.5035.978.708833.5135.972.65 16.0019.8546.059.9410094.4946.053.03 18.0024.6957.2611.1811365.5857.263.41 20.0030.0069.5812.4212626.7969.583.79 22.0035.8083.0013.6613888.1083.004.16 24.0042.0697.4914.9115149.5197.494.54 26.0048.78113.0516.15164011.03113.054.92 28.0055.95129.6617.39176612.66129.665.30 30.0063.58147.3218.63189314.38147.325.68 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 64 1" TYPE “K” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=1.1265 inches (28.613 mm)Nominal O.D.=1.1250 inches (28.575 mm)Minimum O.D.=1.1235 inches (28.537 mm)Nominal I.D.=0.9850 inches (25.273 mm)Nominal Wall Thickness=0.0650 inches (1.651 mm)Flow Area=0.7776 sq. inches (501.65 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)2.500.240.551.031580.050.550.31 5.000.851.982.063150.191.980.63 7.501.804.193.094730.414.190.94 10.003.077.144.136310.707.141.26 12.504.6510.785.167891.0510.781.57 15.006.5115.116.199461.4715.111.89 17.508.6620.107.2211041.9620.102.20 20.0011.0925.738.2512622.5125.732.52 22.5013.8031.999.2814193.1231.992.83 25.0016.7738.8810.3215773.7938.883.14 27.5020.0146.3711.3517354.5346.373.46 30.0023.5154.4712.3818935.3254.473.77 32.5027.2763.1713.4120506.1763.174.09 35.0031.2872.4514.4422087.0872.454.40 37.5035.5482.3115.4723668.0482.314.72 40.0040.0592.7516.5025239.0692.755.03 42.5044.81103.7617.54268110.14103.765.34 45.0049.81115.3318.57283911.27115.335.66 47.5055.06127.4719.60299712.46127.475.97 50.0060.55140.1520.63315413.70140.156.29 52.5066.27153.3921.66331214.99153.396.60 55.0072.24167.1822.69347016.34167.186.92 1" TYPE “L” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=1.1265 inches (28.613 mm)Nominal O.D.=1.1250 inches (28.575 mm)Minimum O.D.=1.1235 inches (28.537 mm)Nominal I.D.=1.0250 inches (26.035 mm)Nominal Wall Thickness=0.0500 inches (1.270 mm)Flow Area=0.8252 sq. inches (532.36 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)2.500.200.480.971580.050.480.30 5.000.741.711.943150.171.710.59 7.501.563.632.924730.353.630.89 10.002.666.183.896310.606.181.19 12.504.029.334.867890.919.331.48 15.005.6413.085.839461.2713.081.78 17.507.5017.396.8011041.7017.392.07 20.009.6022.277.7812622.1722.272.37 22.5011.9427.698.7514192.7027.692.67 25.0014.5233.659.7215773.2833.652.96 27.5017.3240.1310.6917353.9240.133.26 30.0020.3547.1411.6618934.6047.143.56 32.5023.6054.6712.6420505.3454.673.85 35.0027.0762.7013.6122086.1262.704.15 37.5030.7671.2414.5823666.9671.244.44 40.0034.6680.2715.5525237.8480.274.74 42.5038.7889.8016.5226818.7789.805.04 45.0043.1199.8117.5028399.7599.815.33 47.5047.65110.3118.47299710.78110.315.63 50.0052.40121.2919.44315411.85121.295.93 52.5057.36132.7520.41331212.97132.756.22 55.0062.52144.6821.38347014.14144.686.52 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 65 1" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=1.1265 inches (28.613 mm)Nominal O.D.=1.1250 inches (28.575 mm)Minimum O.D.=1.1235 inches (28.537 mm)Nominal I.D.=1.0558 inches (26.797 mm)Nominal Wall Thickness=0.0350 inches (0.889 mm)Flow Area=0.8742 sq. inches (563.98 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)2.500.180.410.921580.040.410.28 5.000.641.491.843150.141.490.56 7.501.363.152.754730.313.150.84 10.002.315.373.676310.525.371.12 12.503.498.114.597890.798.111.40 15.004.9011.365.519461.1111.361.68 17.506.5215.116.4211041.4715.111.96 20.008.3419.357.3412621.8919.352.24 22.5010.3824.068.2614192.3524.062.52 25.0012.6129.249.1815772.8529.242.80 27.5015.0534.8810.0917353.4034.883.08 30.0017.6840.9711.0118934.0040.973.36 32.5020.5147.5111.9320504.6447.513.64 35.0023.5254.4912.8522085.3254.493.92 37.5026.7361.9113.7623666.0561.914.19 40.0030.1269.7614.6825236.8169.764.47 42.5033.7078.0415.6026817.6278.044.75 45.0037.4786.7416.5228398.4786.745.03 47.5041.4195.8717.4329979.3795.875.31 50.0045.54105.4118.35315410.30105.415.59 52.5049.84115.3719.27331211.28115.375.87 55.0054.33125.7420.19347012.29125.746.15 1 1/4" TYPE “K” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=1.3765 inches (34.963 mm)Nominal O.D.=1.3750 inches (34.925 mm)Minimum O.D.=1.3735 inches (34.887 mm)Nominal I.D.=1.2450 inches (31.623 mm)Nominal Wall Thickness=0.0650 inches (1.651 mm)Flow Area=1.2174 sq. inches (785.41 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)5.000.290.671.323150.060.670.40 10.001.032.402.646310.232.400.80 15.002.195.083.959460.495.081.20 20.003.738.655.2712620.848.651.61 25.005.6413.066.5915771.2713.062.01 30.007.9018.307.9118931.7918.302.41 35.0010.5124.349.2222082.3824.342.81 40.0013.4631.1710.5425233.0431.173.21 45.0016.7438.7511.8628393.7938.753.61 50.0020.3547.0913.1831544.6047.094.02 55.0024.2756.1814.4934705.4956.184.42 60.0028.5265.9915.8137856.4565.994.82 65.0033.0776.5217.1341017.4876.525.22 70.0037.9487.7618.4544168.5887.765.62 75.0043.1199.7119.7747329.7599.716.02 80.0048.58112.3521.08504710.99112.356.43 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 66 1 1/4" TYPE “L” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=1.3765 inches (34.963 mm)Nominal O.D.=1.375 inches (34.925 mm)Minimum O.D.=1.3735 inches (34.887 mm)Nominal I.D.=1.265 inches (32.131 mm)Nominal Wall Thickness=0.0550 inches (1.397 mm)Flow Area=1.2568 sq. inches (810.85 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)5.000.260.621.283150.060.620.39 10.000.962.222.556310.222.220.78 15.002.024.703.839460.464.701.17 20.003.458.005.1112620.788.001.56 25.005.2212.096.3815771.1812.091.95 30.007.3116.947.6618931.6516.942.33 35.009.7322.538.9322082.2022.532.72 40.0012.4528.8410.2125232.8228.843.11 45.0015.4935.8611.4928393.5035.863.50 50.0018.8343.5812.7631544.2643.583.89 55.0022.4651.9814.0434705.0851.984.28 60.0026.3961.0615.3237855.9761.064.67 65.0030.6170.8116.5941016.9270.815.06 70.0035.1181.2117.8744167.9481.215.45 75.0039.8992.2719.1547329.0292.275.84 80.0044.96103.9720.42504710.17103.976.22 1 1/4" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=1.3765 inches (34.963 mm)Nominal O.D.=1.3750 inches (34.925 mm)Minimum O.D.=1.3735 inches (34.887 mm)Nominal I.D.=1.2910 inches (32.7914 mm)Nominal Wall Thickness=0.0420 inches (1.067 mm)Flow Area=1.3090 sq. inches (844.52 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)5.000.240.561.233150.050.560.37 10.000.872.012.456310.202.010.75 15.001.834.263.689460.414.261.12 20.003.127.254.9012620.717.251.49 25.004.7210.956.1315771.0710.951.87 30.006.6215.347.3518931.5015.342.24 35.008.8120.408.5822081.9920.402.61 40.0011.2826.129.8025232.5526.122.99 45.0014.0332.4811.0328393.1732.483.36 50.0017.0539.4712.2531543.8639.473.74 55.0020.3447.0813.4834704.6047.084.11 60.0023.9055.3114.7137855.4155.314.48 65.0027.7264.1415.9341016.2764.144.86 70.0031.8073.5617.1644167.1973.565.23 75.0036.1383.5718.3847328.1783.575.60 80.0040.7294.1719.6150479.2194.175.98 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 67 1 1/2" TYPE “K” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=1.6270 inches (41.326 mm)Nominal O.D.=1.6250 inches (41.275 mm)Minimum O.D.=1.6230 inches (41.224 mm)Nominal I.D.=1.4810 inches (38.227 mm)Nominal Wall Thickness=0.0720 inches (1.829 mm)Flow Area=1.7227 sq. inches (1111.39 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)5.000.120.290.933150.030.290.28 10.000.441.031.866310.101.030.57 15.000.942.182.799460.212.180.85 20.001.603.723.7212620.363.721.14 25.002.425.614.6615770.555.611.42 30.003.397.875.5918930.777.871.70 35.004.5210.466.5222081.0210.461.99 40.005.7813.397.4525231.3113.392.27 45.007.1916.658.3828391.6316.652.55 50.008.7420.249.3131541.9820.242.84 55.0010.4324.1410.2434702.3624.143.12 60.0012.2628.3611.1737852.7728.363.41 65.0014.2132.8812.1141013.2232.883.69 70.0016.3037.7213.0444163.6937.723.97 75.0018.5342.8513.9747324.1942.854.26 80.0020.8848.2814.9050474.7248.284.54 85.0023.3654.0115.8353625.2854.014.83 90.0025.9760.0416.7656785.8760.045.11 95.0028.7066.3517.6959936.4966.355.39 100.0031.5672.9618.6263097.1472.965.68 105.0034.5579.8519.5666247.8279.855.96 110.0037.6687.0320.4969408.5287.036.24 115.0040.8994.4921.4272559.2594.496.53 1 1/2" TYPE “L” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=1.6270 inches (41.326 mm)Nominal O.D.=1.6250 inches (41.275 mm)Minimum O.D.=1.6230 inches (41.224 mm)Nominal I.D.=1.5050 inches (37.6174 mm)Nominal Wall Thickness=0.0600 inches (1.524 mm)Flow Area=1.7789 sq. inches (1147.71 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)5.000.110.260.903150.030.260.27 10.000.410.951.806310.090.950.55 15.000.872.022.719460.202.020.82 20.001.483.443.6112620.343.441.10 25.002.245.194.5115770.515.191.37 30.003.147.275.4118930.717.271.65 35.004.189.676.3122080.949.671.92 40.005.3512.397.2125231.2112.392.20 45.006.6515.408.1228391.5015.402.47 50.008.0918.729.0231541.8318.722.75 55.009.6522.329.9234702.1822.323.02 60.0011.3326.2210.8237852.5626.223.30 65.0013.1430.4111.7241012.9730.413.57 70.0015.0834.8812.6244163.4134.883.85 75.0017.1339.6313.5347323.8839.634.12 80.0019.3144.6514.4350474.3744.654.40 85.0021.6049.9515.3353624.8949.954.67 90.0024.0155.5216.2356785.4355.524.95 95.0026.5461.3617.1359936.0061.365.22 100.0029.1967.4718.0363096.6067.475.50 105.0031.9573.8418.9466247.2373.845.77 110.0034.8280.4819.8469407.8880.486.05 115.0037.8187.3820.7472558.5587.386.32 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 68 1 1/2" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=1.6270 inches (41.326 mm)Nominal O.D.=1.6250 inches (41.275 mm)Minimum O.D.=1.6230 inches (41.224 mm)Nominal I.D.=1.5270 inches (38.7858 mm)Nominal Wall Thickness=0.0490 inches (1.2446 mm)Flow Area=1.8313 sq. inches (1181.50 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)5.000.110.250.883150.020.250.27 10.000.380.891.756310.090.890.53 15.000.811.882.639460.181.880.80 20.001.383.203.5012620.313.201.07 25.002.094.844.3815770.474.841.33 30.002.936.785.2618930.666.781.60 35.003.899.026.1322080.889.021.87 40.004.9811.547.0125231.1311.542.14 45.006.2014.357.8828391.4014.352.40 50.007.5317.448.7631541.7017.442.67 55.008.9920.809.6434702.0320.802.94 60.0010.5624.4410.5137852.3924.443.20 65.0012.2528.3411.3941012.7728.343.47 70.0014.0532.5012.2644163.1832.503.74 75.0015.9636.9213.1447323.6136.924.00 80.0017.9941.6114.0250474.0741.614.27 85.0020.1346.5514.8953624.5546.554.54 90.0022.3851.7415.7756785.0651.744.81 95.0024.7357.1816.6459935.5957.185.07 100.0027.2062.8717.5263096.1562.875.34 105.0029.7768.8118.4066246.7368.815.61 110.0032.4574.9919.2769407.3474.995.87 115.0035.2381.4220.1572557.9781.426.14 2" TYPE “K” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=2.1270 inches (54.026 mm)Nominal O.D.=2.1250 inches (53.975 mm)Minimum O.D.=2.1230 inches (53.924 mm)Nominal I.D.=1.9590 inches (49.7586 mm)Nominal Wall Thickness=0.0830 inches (2.1082 mm)Flow Area=3.0141 sq. inches (1944.58 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)100.110.261.066310.030.260.32 200.410.952.1312620.090.950.65 300.872.023.1918930.202.020.97 401.483.434.2625230.343.431.30 502.245.195.3231540.515.191.62 603.147.276.3937850.717.271.95 704.189.677.4544160.959.672.27 805.3512.388.5250471.2112.382.60 906.6615.399.5856781.5115.392.92 1008.0918.7110.6463091.8318.713.24 1109.6622.3211.7169402.1822.323.57 12011.3426.2112.7775702.5726.213.89 13013.1630.4013.8482012.9830.404.22 14015.0934.8614.9088323.4134.864.54 15017.1539.6115.9794633.8839.614.87 16019.3344.6317.03100944.3744.635.19 17021.6249.9318.10107254.8949.935.52 18024.0455.5019.16113565.4455.505.84 19026.5761.3420.22119866.0161.346.16 20029.2267.4421.29126176.6167.446.49 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 69 2" TYPE “L” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=2.1270 inches (54.026 mm)Nominal O.D.=2.1250 inches (53.975 mm)Minimum O.D.=2.1230 inches (53.924 mm)Nominal I.D.=1.9850 inches (50.419 mm)Nominal Wall Thickness=0.0700 inches (1.778 mm)Flow Area=3.0946 sq. inches (1996.54 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)100.110.251.046310.020.250.32 200.390.892.0712620.090.890.63 300.821.893.1118930.181.890.95 401.393.224.1525230.313.221.26 502.104.875.1831540.484.871.58 602.956.826.2237850.676.821.90 703.929.077.2644160.899.072.21 805.0211.618.2950471.1411.612.53 906.2414.449.3356781.4114.442.84 1007.5917.5510.3763091.7217.553.16 1109.0620.9311.4069402.0520.933.48 12010.6424.5812.4475702.4124.583.79 13012.3428.5113.4882012.7928.514.11 14014.1532.7014.5188323.2032.704.42 15016.0837.1515.5594633.6437.154.74 16018.1341.8616.59100944.1041.865.06 17020.2846.8317.62107254.5946.835.37 18022.5452.0518.66113565.1052.055.69 19024.9257.5319.70119865.6457.536.00 20027.4063.2520.73126176.2063.256.32 2" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=2.1270 inches (54.026 mm)Nominal O.D.=2.1250 inches (53.975 mm)Minimum O.D.=2.1230 inches (53.924 mm)Nominal I.D.=2.0090 inches (51.0286 mm)Nominal Wall Thickness=0.0580 inches (1.4732 mm)Flow Area=3.1699 sq. inches (2045.11 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)100.100.231.016310.020.230.31 200.360.842.0212620.080.840.62 300.771.783.0418930.171.780.93 401.313.044.0525230.303.041.23 501.984.595.0631540.454.591.54 602.786.436.0737850.636.431.85 703.708.557.0844160.848.552.16 804.7410.958.1050471.0710.952.47 905.8913.629.1156781.3313.622.78 1007.1616.5510.1263091.6216.553.08 1108.5419.7411.1369401.9319.743.39 12010.0323.1912.1575702.2723.193.70 13011.6426.8913.1682012.6326.894.01 14013.3530.8414.1788323.0230.844.32 15015.1735.0415.1894633.4335.044.63 16017.1039.4816.19100943.8739.484.94 17019.1344.1717.21107254.3344.175.24 18021.2649.0918.22113564.8149.095.55 19023.5054.2619.23119865.3254.265.86 20025.8459.6620.24126175.8559.666.17 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 70 2 1/2" TYPE “K” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=2.6270 inches (66.7258 mm)Nominal O.D.=2.6250 inches (66.675 mm)Minimum O.D.=2.6230 inches (66.6242 mm)Nominal I.D.=2.4350 inches (61.849 mm)Nominal Wall Thickness=0.0950 inches (2.413 mm)Flow Area=4.6568 sq. inches (3004.380 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)200.140.331.3812620.030.330.42 400.511.192.7625230.121.190.84 601.092.524.1337850.252.521.26 801.864.305.5150470.424.301.68 1002.816.496.8963090.646.492.10 1203.949.108.2775700.899.102.52 1405.2412.109.6588321.1812.102.94 1606.7115.4911.02100941.5215.493.36 1808.3419.2612.40113561.8919.263.78 20010.1423.4113.78126172.2923.414.20 22012.1027.9215.16138792.7427.924.62 24014.2132.7916.53151413.2132.795.04 26016.4838.0317.91164033.7338.035.46 28018.9143.6219.29176644.2843.625.88 30021.4849.5520.67189264.8649.556.30 32024.2155.8422.05201885.4855.846.72 2 1/2" TYPE “L” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=2.6270 inches (66.7258 mm)Nominal O.D.=2.6250 inches (66.675 mm)Minimum O.D.=2.6230 inches (66.6242 mm)Nominal I.D.=2.4650 inches (62.611 mm)Nominal Wall Thickness=0.0800 inches (2.032 mm)Flow Area=4.7723 sq. inches (3078.87 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)200.130.311.3412620.030.310.41 400.481.122.6925230.111.120.82 601.032.384.0337850.232.381.23 801.754.055.3850470.404.051.64 1002.656.126.7263090.606.122.05 1203.718.578.0775700.848.572.46 1404.9311.409.4188321.1211.402.87 1606.3214.5910.76100941.4314.593.28 1807.8618.1512.10113561.7818.153.69 2009.5522.0513.45126172.1622.054.10 22011.4026.3014.79138792.5826.304.51 24013.3930.9016.13151413.0330.904.92 26015.5335.8317.48164033.5135.835.33 28017.8141.0918.82176644.0341.095.74 30020.2446.6920.17189264.5846.696.15 32022.8152.6121.51201885.1652.616.56 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 71 2 1/2" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=2.6270 inches (66.7258 mm)Nominal O.D.=2.6250 inches (66.675 mm)Minimum O.D.=2.6230 inches (66.6242 mm)Nominal I.D.=2.4950 inches (63.373 mm)Nominal Wall Thickness=0.0650 inches (1.651 mm)Flow Area=4.8891 sq. inches (3154.27 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)200.130.291.3112620.030.290.40 400.461.062.6225230.101.060.80 600.972.243.9437850.222.241.20 801.653.825.2550470.373.821.60 1002.505.776.5663090.565.772.00 1203.508.087.8775700.798.082.40 1404.6510.759.1988321.0510.752.80 1605.9613.7610.50100941.3513.763.20 1807.4117.1111.81113561.6817.113.60 2009.0120.7913.12126172.0420.794.00 22010.7524.8014.44138792.4324.804.40 24012.6229.1315.75151412.8629.134.80 26014.6433.7817.06164033.3133.785.20 28016.8038.7518.37176643.8038.755.60 30019.0944.0219.69189264.3244.026.00 32021.5149.6021.00201884.8749.606.40 3" TYPE “K” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=3.1270 inches (79.4258 mm)Nominal O.D.=3.1250 inches (79.375 mm)Minimum O.D.=3.1230 inches (79.3242 mm)Nominal I.D.=2.9070 inches (73.8378 mm)Nominal Wall Thickness=0.1090 inches (2.7686 mm)Flow Area=6.6371 sq. inches (4282.01 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)250.090.211.2115770.020.210.37 500.330.762.4231540.070.760.74 750.701.613.6347320.161.611.11 1001.192.744.8363090.272.741.47 1251.794.146.0478860.414.141.84 1502.515.807.2594630.575.802.21 1753.347.728.46110400.767.722.58 2004.289.889.67126170.979.882.95 2255.3312.2910.88141951.2012.293.32 2506.4714.9412.08157721.4614.943.68 2757.7217.8213.29173491.7517.824.05 3009.0720.9314.50189262.0520.934.42 32510.5224.2715.71205032.3824.274.79 35012.0727.8316.92220802.7327.835.16 37513.7231.6218.13236583.1031.625.53 40015.4635.6319.34252353.5035.635.89 42517.2939.8620.54268123.9139.866.26 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 72 3" TYPE “L” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=3.1270 inches (79.4258 mm)Nominal O.D.=3.1250 inches (79.375 mm)Minimum O.D.=3.1230 inches (79.3242 mm)Nominal I.D.=2.9450 inches (74.803 mm)Nominal Wall Thickness=0.0900 inches (2.286 mm)Flow Area=6.8118 sq. inches (4394.69 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)250.090.201.1815770.020.200.36 500.310.712.3531540.070.710.72 750.651.513.5347320.151.511.08 1001.112.574.7163090.252.571.44 1251.683.895.8978860.383.891.79 1502.365.457.0694630.535.452.15 1753.147.258.24110400.717.252.51 2004.029.289.42126170.919.282.87 2255.0011.5410.60141951.1311.543.23 2506.0814.0211.77157721.3714.023.59 2757.2516.7212.95173491.6416.723.95 3008.5219.6514.13189261.9319.654.31 3259.8822.7815.31205032.2322.784.67 35011.3326.1316.48220802.5626.135.02 37512.8829.6917.66236582.9129.695.38 40014.5133.4518.84252353.2833.455.74 42516.2437.4220.02268123.6737.426.10 3" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=3.1270 inches (79.4258 mm)Nominal O.D.=3.1250 inches (79.375 mm)Minimum O.D.=3.1230 inches (79.3242 mm)Nominal I.D.=2.9810 inches (75.7174 mm)Nominal Wall Thickness=0.0720 inches (1.8288 mm)Flow Area=6.9793 sq. inches (4502.79 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)250.080.191.1515770.020.190.35 500.290.672.3031540.070.670.70 750.621.423.4547320.141.421.05 1001.052.434.6063090.242.431.40 1251.593.675.7578860.363.671.75 1502.225.146.9094630.505.142.10 1752.966.838.04110400.676.832.45 2003.798.759.19126170.868.752.80 2254.7110.8810.34141951.0710.883.15 2505.7313.2211.49157721.3013.223.50 2756.8315.7612.64173491.5515.763.85 3008.0318.5213.79189261.8218.524.20 3259.3121.4714.94205032.1121.474.55 35010.6824.6316.09220802.4224.634.90 37512.1427.9817.24236582.7527.985.25 40013.6831.5318.39252353.0931.535.60 42515.3035.2719.54268123.4635.275.95 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 73 3 1/2" TYPE “K” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=3.6270 inches (92.1258 mm)Nominal O.D.=3.6250 inches (92.075 mm)Minimum O.D.=3.6230 inches (92.0242 mm)Nominal I.D.=3.3850 inches (85.979 mm)Nominal Wall Thickness=0.1200 inches (3.048 mm)Flow Area=6.9993 sq. inches (5805.97 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)250.040.100.8915770.010.100.27 500.160.361.7831540.040.360.54 750.330.772.6747320.080.770.81 1000.571.313.5763090.131.311.09 1250.851.984.4678860.191.981.36 1501.202.775.3594630.272.771.63 1751.593.686.24110400.363.681.90 2002.044.717.13126170.464.712.17 2252.545.868.02141950.575.862.44 2503.097.128.91157720.707.122.72 2753.688.499.80173490.838.492.99 3004.339.9810.70189260.989.983.26 3255.0211.5711.59205031.1311.573.53 3505.7613.2712.48220801.3013.273.80 3756.5415.0813.37236581.4815.084.07 4007.3716.9914.26252351.6716.994.35 4258.2519.0115.15268121.8719.014.62 4509.1721.1216.04283892.0721.124.89 47510.1323.3516.93299662.2923.355.16 50011.1425.6717.83315432.5225.675.43 52512.2028.1018.72331212.7628.105.70 55013.2930.6219.61346983.0130.625.98 57514.4333.2520.50362753.2633.256.25 60015.6235.9721.39378523.5335.976.52 3 1/2" TYPE “L” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=3.6270 inches (92.1258 mm)Nominal O.D.=3.6250 inches (92.075 mm)Minimum O.D.=3.6230 inches (92.0242 mm)Nominal I.D.=3.4250 inches (86.995 mm)Nominal Wall Thickness=0.1000 inches (2.540 mm)Flow Area=9.2132 sq. inches (5944.00 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)250.040.090.8715770.010.090.27 500.150.341.7431540.030.340.53 750.310.732.6147320.070.730.80 1000.531.233.4863090.121.231.06 1250.811.874.3578860.181.871.33 1501.132.615.2294630.262.611.59 1751.513.486.09110400.343.481.86 2001.934.456.96126170.444.452.12 2252.405.537.84141950.545.532.39 2502.916.738.71157720.666.732.65 2753.488.029.58173490.798.022.92 3004.099.4210.45189260.929.423.18 3254.7410.9311.32205031.0710.933.45 3505.4412.5312.19220801.2312.533.71 3756.1814.2413.06236581.4014.243.98 4006.9616.0513.93252351.5716.054.25 4257.7917.9514.80268121.7617.954.51 4508.6619.9515.67283891.9619.954.78 4759.5722.0516.54299662.1622.055.04 50010.5224.2517.41315432.3824.255.31 52511.5226.5418.28331212.6126.545.57 55012.5528.9219.15346982.8428.925.84 57513.6331.4020.02362753.0831.406.10 60014.7533.9720.89378523.3433.976.37 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 74 3 1/2" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=3.6270 inches (92.1258 mm)Nominal O.D.=3.6250 inches (92.075 mm)Minimum O.D.=3.6230 inches (92.0242 mm)Nominal I.D.=3.4590 inches (87.8586 mm)Nominal Wall Thickness=0.0830 inches (2.1082 mm)Flow Area=9.397 sq. inches (6062.59 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)250.040.090.8515770.010.090.26 500.140.331.7131540.030.330.52 750.300.692.5647320.070.690.78 1000.511.183.4163090.121.181.04 1250.771.784.2778860.171.781.30 1501.082.495.1294630.242.491.56 1751.443.315.97110400.323.311.82 2001.844.246.83126170.424.242.08 2252.295.277.68141950.525.272.34 2502.786.418.54157720.636.412.60 2753.317.659.39173490.757.652.86 3003.898.9810.24189260.888.983.12 3254.5210.4111.10205031.0210.413.38 3505.1811.9411.95220801.1711.943.64 3755.8913.5712.80236581.3313.573.90 4006.6315.2913.66252351.5015.294.16 4257.4217.1114.51268121.6817.114.42 4508.2519.0215.36283891.8719.024.68 4759.1221.0216.22299662.0621.024.94 50010.0323.1117.07315432.2723.115.20 52510.9825.2917.92331212.4825.295.46 55011.9627.5618.78346982.7127.565.72 57512.9929.9319.63362752.9429.935.98 60014.0632.3820.49378523.1832.386.24 4" TYPE “K” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=4.1270 inches (104.8258 mm)Nominal O.D.=4.1250 inches (104.775 mm)Minimum O.D.=4.1230 inches (104.7242 mm)Nominal I.D.=3.8570 inches (97.9678 mm)Nominal Wall Thickness=0.1340 inches (3.4036 mm)Flow Area=11.6839 sq. inches (7538.01 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)500.080.191.3731540.020.190.42 1000.300.692.7563090.070.690.84 1500.631.474.1294630.141.471.26 2001.082.505.49126170.242.501.67 2501.643.776.86157720.373.772.09 3002.295.298.24189260.525.292.51 3503.057.039.61220800.697.032.93 4003.919.0010.98252350.889.003.35 4504.8611.1912.36283891.1011.193.77 5005.9013.6013.73315431.3413.604.18 5507.0416.2315.10346981.5916.234.60 6008.2719.0616.48378521.8719.065.02 6509.6022.1017.85410062.1722.105.44 70011.0125.3519.22441612.4925.355.86 75012.5128.8020.59473152.8328.806.28 80014.1032.4521.97504693.1932.456.70 85015.7736.3023.34536243.5736.307.11 90017.5340.3524.71567783.9740.357.53 95019.3844.6026.09599324.3844.607.95 100021.3149.0427.46630874.8249.048.37 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 75 4" TYPE “L” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=4.1270 inches (104.8258 mm)Nominal O.D.=4.1250 inches (104.775 mm)Minimum O.D.=4.1230 inches (104.7242 mm)Nominal I.D.=3.9050 inches (99.187 mm)Nominal Wall Thickness=0.1100 inches (2.794 mm)Flow Area=11.9766 sq. inches (7726.80 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)500.080.181.3431540.020.180.41 1000.280.652.6863090.060.650.82 1500.601.384.0294630.141.381.22 2001.022.355.36126170.232.351.63 2501.543.556.70157720.353.552.04 3002.164.988.04189260.494.982.45 3502.876.629.38220800.656.622.86 4003.688.4810.72252350.838.483.27 4504.5710.5412.05283891.0310.543.67 5005.5612.8113.39315431.2612.814.08 5506.6315.2814.73346981.5015.284.49 6007.7917.9516.07378521.7617.954.90 6509.0420.8117.41410062.0420.815.31 70010.3723.8718.75441612.3423.875.72 75011.7827.1220.09473152.6627.126.12 80013.2730.5621.43504693.0030.566.53 85014.8534.1822.77536243.3634.186.94 90016.5138.0024.11567783.7338.007.35 95018.2541.9925.45599324.1341.997.76 100020.0746.1726.79630874.5446.178.17 4" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=4.1270 inches (104.8258 mm)Nominal O.D.=4.1250 inches (104.775 mm)Minimum O.D.=4.1230 inches (104.7242 mm)Nominal I.D.=3.9350 inches (99.949 mm)Nominal Wall Thickness=0.0950 inches (2.413 mm)Flow Area=12.1613 sq. inches (7845.87 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)500.080.171.3231540.020.170.40 1000.270.632.6463090.060.630.80 1500.581.333.9694630.131.331.21 2000.982.275.28126170.222.271.61 2501.483.426.60157720.343.422.01 3002.084.807.91189260.474.802.41 3502.776.389.23220800.636.382.81 4003.548.1710.55252350.808.173.22 4504.4110.1511.87283891.0010.153.62 5005.3612.3413.19315431.2112.344.02 5506.3914.7214.51346981.4514.724.42 6007.5117.2915.83378521.7017.294.82 6508.7120.0517.15410061.9720.055.23 7009.9923.0018.47441612.2623.005.63 75011.3526.1319.79473152.5726.136.03 80012.7929.4421.11504692.8929.446.43 85014.3132.9322.42536243.2432.936.83 90015.9136.6123.74567783.6036.617.24 95017.5840.4625.06599323.9840.467.64 100019.3344.4926.38630874.3744.498.04 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 76 5" TYPE “K” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=5.1270 inches (130.2258 mm)Nominal O.D.=5.1250 inches (130.175 mm)Minimum O.D.=5.1230 inches (130.1242 mm)Nominal I.D.=4.8050 inches (122.047 mm)Nominal Wall Thickness=0.1600 inches (4.064 mm)Flow Area=18.1333 sq. inches (11698.87 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)500.030.070.8831540.010.070.27 1000.100.241.7763090.020.240.54 1500.220.502.6594630.050.500.81 2000.370.863.54126170.080.861.08 2500.561.304.42157720.131.301.35 3000.791.815.31189260.181.811.62 3501.052.416.19220800.242.411.89 4001.343.097.08252350.303.092.16 4501.673.847.96283890.383.842.43 5002.034.678.85315430.464.672.70 5502.425.579.73346980.555.572.97 6002.846.5410.62378520.646.543.24 6503.297.5911.50410060.757.593.51 7003.788.7012.39441610.858.703.77 7504.299.8913.27473150.979.894.04 8004.8411.1414.15504691.0911.144.31 8505.4112.4615.04536241.2212.464.58 9006.0213.8515.92567781.3613.854.85 9506.6515.3116.81599321.5015.315.12 10007.3216.8317.69630871.6516.835.39 10508.0118.4218.58662411.8118.425.66 11008.7320.0819.46693951.9720.085.93 11509.4821.8020.35725502.1421.806.20 5" TYPE “L” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=5.1270 inches (130.2258 mm)Nominal O.D.=5.1250 inches (130.175 mm)Minimum O.D.=5.1230 inches (130.1242 mm)Nominal I.D.=4.8750 inches (123.825 mm)Nominal Wall Thickness=0.1250 inches (3.175 mm)Flow Area=18.6655 sq. inches (12042.22 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)500.030.060.8631540.010.060.26 1000.100.221.7263090.020.220.52 1500.200.472.5894630.050.470.79 2000.350.803.44126170.080.801.05 2500.521.214.30157720.121.211.31 3000.731.695.16189260.171.691.57 3500.982.256.02220800.222.251.83 4001.252.886.88252350.282.882.10 4501.553.587.73283890.353.582.36 5001.894.358.59315430.434.352.62 5502.255.199.45346980.515.192.88 6002.656.1010.31378520.606.103.14 6503.077.0711.17410060.697.073.41 7003.528.1112.03441610.808.113.67 7504.009.2112.89473150.919.213.93 8004.5110.3813.75504691.0210.384.19 8505.0511.6114.61536241.1411.614.45 9005.6112.9115.47567781.2712.914.72 9506.2014.2716.33599321.4014.274.98 10006.8215.6917.19630871.5415.695.24 10507.4617.1718.05662411.6917.175.50 11008.1318.7118.91693951.8418.715.76 11508.8320.3219.77725502.0020.326.02 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 77 5" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=5.1270 inches (130.2258 mm)Nominal O.D.=5.1250 inches (130.175 mm)Minimum O.D.=5.1230 inches (130.1242 mm)Nominal I.D.=4.9070 inches (124.6378 mm)Nominal Wall Thickness=0.1090 inches (2.7686 mm)Flow Area=18.9113 sq. inches (12200.83 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)500.030.060.8531540.010.060.26 1000.090.211.7063090.020.210.52 1500.200.452.5494630.040.450.78 2000.340.773.39126170.080.771.03 2500.511.174.24157720.111.171.29 3000.711.645.09189260.161.641.55 3500.952.185.94220800.212.181.81 4001.212.796.79252350.272.792.07 4501.513.477.63283890.343.472.33 5001.834.228.48315430.414.222.59 5502.185.039.33346980.495.032.84 6002.565.9110.18378520.585.913.10 6502.976.8511.03410060.676.853.36 7003.417.8611.88441610.777.863.62 7503.888.9312.72473150.888.933.88 8004.3710.0613.57504690.9910.064.14 8504.8911.2514.42536241.1111.254.40 9005.4312.5115.27567781.2312.514.65 9506.0113.8216.12599321.3613.824.91 10006.6015.2016.97630871.4915.205.17 10507.2316.6317.81662411.6416.635.43 11007.8818.1318.66693951.7818.135.69 11508.5619.6819.51725501.9419.685.95 6" TYPE “K” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=6.1270 inches (155.6258 mm)Nominal O.D.=6.1250 inches (155.575 mm)Minimum O.D.=6.1230 inches (155.5242 mm)Nominal I.D.=5.7410 inches (145.8214 mm)Nominal Wall Thickness=0.1920 inches (4.8768 mm)Flow Area=25.8860 sq. inches (16700.61 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)1000.040.101.2463090.010.100.38 2000.160.362.48126170.040.360.76 3000.330.763.72189260.070.761.13 4000.561.304.96252350.131.301.51 5000.851.966.20315430.191.961.89 6001.192.757.44378520.272.752.27 7001.593.668.68441610.363.662.64 8002.044.699.92504690.464.693.02 9002.535.8311.15567780.575.833.40 10003.087.0812.39630870.707.083.78 11003.678.4513.63693950.838.454.16 12004.319.9214.87757040.989.924.53 13005.0011.5016.11820131.1311.504.91 14005.7413.1917.35883211.3013.195.29 15006.5214.9918.59946301.4714.995.67 16007.3516.8919.831009391.6616.896.04 17008.2218.9021.071072471.8618.906.42 18009.1421.0022.311135562.0721.006.80 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 78 6" TYPE “L” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=6.1270 inches (155.6258 mm)Nominal O.D.=6.1250 inches (155.575 mm)Minimum O.D.=6.1230 inches (155.5242 mm)Nominal I.D.=5.8450 inches (148.463 mm)Nominal Wall Thickness=0.1400 inches (3.556 mm)Flow Area=26.8324 sq. inches (17311.17 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)1000.040.091.2063090.010.090.36 2000.140.332.39126170.030.330.73 3000.300.703.59189260.070.701.09 4000.521.194.78252350.121.191.46 5000.781.805.98315430.181.801.82 6001.092.527.17378520.252.522.19 7001.463.358.37441610.333.352.55 8001.874.299.57504690.424.292.92 9002.325.3410.76567780.525.343.28 10002.826.4911.96630870.646.493.64 11003.367.7413.15693950.767.744.01 12003.959.0914.35757040.899.094.37 13004.5810.5415.54820131.0410.544.74 14005.2612.0916.74883211.1912.095.10 15005.9813.7417.94946301.3513.745.47 16006.7315.4819.131009391.5215.485.83 17007.5317.3220.331072471.7017.326.20 18008.3819.2521.521135561.8919.256.56 6" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=6.1270 inches (155.6258 mm)Nominal O.D.=6.1250 inches (155.575 mm)Minimum O.D.=6.1230 inches (155.5242 mm)Nominal I.D.=5.8810 inches (149.3774 mm)Nominal Wall Thickness=0.1220 inches (3.0988 mm)Flow Area=27.1639 sq. inches (17525.07 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)1000.040.091.1863090.010.090.36 2000.140.322.36126170.030.320.72 3000.290.683.54189260.070.681.08 4000.501.164.72252350.111.161.44 5000.761.755.91315430.171.751.80 6001.062.457.09378520.242.452.16 7001.413.268.27441610.323.262.52 8001.814.179.45504690.414.172.88 9002.255.1810.63567780.515.183.24 10002.746.3011.81630870.626.303.60 11003.277.5112.99693950.747.513.96 12003.848.8214.17757040.878.824.32 13004.4510.2315.35820131.0110.234.68 14005.1011.7416.54883211.1511.745.04 15005.8013.3317.72946301.3113.335.40 16006.5415.0218.901009391.4815.025.76 17007.3116.8120.081072471.6516.816.12 18008.1318.6821.261135561.8418.686.48 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 79 8" TYPE “K” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=8.1270 inches (206.4258 mm)Nominal O.D.=8.1240 inches (206.3496 mm)Minimum O.D.=8.1210 inches (206.2734 mm)Nominal I.D.=7.5820 inches (192.5828 mm)Nominal Wall Thickness=0.2710 inches (6.8834 mm)Flow Area=45.1500 sq. inches (29128.95 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)2000.040.091.42126170.010.090.43 4000.150.342.84252350.030.340.87 6000.310.714.26378520.070.711.30 8000.531.215.68504690.121.211.73 10000.801.837.11630870.181.832.17 12001.112.568.53757040.252.562.60 14001.483.419.95883210.343.413.03 16001.904.3611.371009390.434.363.47 18002.365.4312.791135560.535.433.90 20002.876.6014.211261730.656.604.33 22003.427.8715.631387910.777.874.76 24004.029.2417.051514080.919.245.20 26004.6710.7218.481640251.0610.725.63 28005.3512.2919.901766431.2112.296.06 30006.0813.9621.321892601.3813.966.50 32006.8515.7322.742018771.5515.736.93 34007.6717.6024.162144951.7317.607.36 36008.5319.5725.582271121.9319.577.80 38009.4221.6227.002397292.1321.628.23 400010.3623.7828.422523472.3423.788.66 8" TYPE “L” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=8.1270 inches (206.4258 mm)Nominal O.D.=8.1240 inches (206.3496 mm)Minimum O.D.=8.1210 inches (206.2734 mm)Nominal I.D.=7.7240 inches (196.1896 mm)Nominal Wall Thickness=0.2000 inches (5.080 mm)Flow Area=46.8570 sq. inches (30230.26 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)2000.040.091.37126170.010.090.42 4000.130.312.74252350.030.310.83 6000.280.654.11378520.060.651.25 8000.481.115.48504690.111.111.67 10000.731.676.85630870.161.672.09 12001.022.348.22757040.232.342.50 14001.353.129.59883210.313.122.92 16001.733.9910.961009390.393.993.34 18002.164.9612.321135560.494.963.76 20002.626.0313.691261730.596.034.17 22003.137.1915.061387910.717.194.59 24003.688.4416.431514080.838.445.01 26004.269.7917.801640250.969.795.43 28004.8911.2319.171766431.1111.235.84 30005.5612.7620.541892601.2612.766.26 32006.2614.3821.912018771.4214.386.68 34007.0116.0823.282144951.5816.087.10 36007.7917.8824.652271121.7617.887.51 38008.6119.7626.022397291.9519.767.93 40009.4721.7227.392523472.1421.728.35 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 80 8" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=8.1270 inches (206.4258 mm)Nominal O.D.=8.1240 inches (206.3496 mm)Minimum O.D.=8.1210 inches (206.2734 mm)Nominal I.D.=7.7840 inches (197.7136 mm)Nominal Wall Thickness=0.1700 inches (4.3180 mm)Flow Area=47.5878 sq. inches (30701.74 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)2000.040.081.35126170.010.080.41 4000.130.302.70252350.030.300.82 6000.270.634.05378520.060.631.23 8000.461.075.39504690.101.071.64 10000.701.616.74630870.161.612.05 12000.982.268.09757040.222.262.47 14001.303.009.44883210.303.002.88 16001.673.8410.791009390.383.843.29 18002.084.7812.141135560.474.783.70 20002.535.8013.481261730.575.804.11 22003.016.9214.831387910.686.924.52 24003.548.1316.181514080.808.134.93 26004.119.4317.531640250.939.435.34 28004.7110.8118.881766431.0710.815.75 30005.3512.2920.231892601.2112.296.16 32006.0313.8521.572018771.3613.856.58 34006.7515.4922.922144951.5315.496.99 36007.5017.2224.272271121.7017.227.40 38008.2919.0325.622397291.8819.037.81 40009.1220.9226.972523472.0620.928.22 10" TYPE “K” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=10.1270 inches (257.2258 mm)Nominal O.D.=10.1230 inches (257.1242 mm)Minimum O.D.=10.1190 inches (257.0226 mm)Nominal I.D.=9.4470 inches (239.9538 mm)Nominal Wall Thickness=0.3380 inches (8.5852 mm)Flow Area=70.0935 sq. inches (45221.52 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)2000.010.030.92126170.000.030.28 4000.050.121.83252350.010.120.56 6000.110.242.75378520.020.240.84 8000.180.423.66504690.040.421.12 10000.270.634.58630870.060.631.40 12000.380.885.49757040.090.881.67 14000.511.176.41883210.121.171.95 16000.651.507.321009390.151.502.23 18000.811.868.241135560.181.862.51 20000.982.269.151261730.222.262.79 22001.172.7010.071387910.272.703.07 24001.383.1710.991514080.313.173.35 26001.603.6811.901640250.363.683.63 28001.844.2212.821766430.424.223.91 30002.094.7913.731892600.474.794.19 32002.355.4014.652018770.535.404.46 34002.636.0415.562144950.606.044.74 36002.926.7116.482271120.666.715.02 38003.237.4217.392397290.737.425.30 40003.558.1618.312523470.808.165.58 42003.898.9319.222649640.888.935.86 44004.249.7320.142775810.969.736.14 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 81 10" TYPE “L” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=10.1270 inches (257.2258 mm)Nominal O.D.=10.1230 inches (257.1242 mm)Minimum O.D.=10.1190 inches (257.0226 mm)Nominal I.D.=9.6230 inches (244.4242 mm)Nominal Wall Thickness=0.2500 inches (6.3500 mm)Flow Area=72.7295 sq. inches (46922.19 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)2000.010.030.8812617.330.000.030.27 4000.050.111.7625234.670.010.110.54 6000.100.222.6537852.000.020.220.81 8000.160.383.5350469.330.040.381.08 10000.250.574.4163086.670.060.571.34 12000.350.805.2975704.000.080.801.61 14000.461.076.1888321.330.111.071.88 16000.601.377.06100938.670.131.372.15 18000.741.707.94113556.000.171.702.42 20000.902.078.82126173.330.202.072.69 22001.072.479.70138790.670.242.472.96 24001.262.9010.59151408.000.292.903.23 26001.463.3611.47164025.330.333.363.50 28001.683.8512.35176642.670.383.853.76 30001.914.3813.23189260.000.434.384.03 32002.154.9314.12201877.330.494.934.30 34002.405.5215.00214494.670.545.524.57 36002.676.1315.88227112.000.606.134.84 38002.956.7816.76239729.330.676.785.11 40003.257.4517.65252346.670.737.455.38 42003.568.1618.53264964.000.808.165.65 44003.888.8919.41277581.330.888.895.92 10" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=10.1270 inches (257.2258 mm)Nominal O.D.=10.1230 inches (257.1242 mm)Minimum O.D.=10.1190 inches (257.0226 mm)Nominal I.D.=9.6990 inches (247.3546 mm)Nominal Wall Thickness=0.2120 inches (5.3848 mm)Flow Area=73.8829 sq. inches (47666.28 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)2000.010.030.87126170.000.030.26 4000.040.101.74252350.010.100.53 6000.090.212.61378520.020.210.79 8000.160.373.47504690.040.371.06 10000.240.554.34630870.050.551.32 12000.340.775.21757040.080.771.59 14000.451.036.08883210.101.031.85 16000.571.326.951009390.131.322.12 18000.711.647.821135560.161.642.38 20000.871.998.681261730.201.992.65 22001.032.379.551387910.232.372.91 24001.212.7910.421514080.272.793.18 26001.413.2311.291640250.323.233.44 28001.623.7112.161766430.373.713.71 30001.844.2113.031892600.424.213.97 32002.074.7513.902018770.474.754.24 34002.315.3114.762144950.525.314.50 36002.575.9015.632271120.585.904.76 38002.846.5316.502397290.646.535.03 40003.137.1717.372523470.717.175.29 42003.427.8518.242649640.777.855.56 44003.738.5619.112775810.848.565.82 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 82 12" TYPE “K” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=12.1270 inches (308.0258 mm)Nominal O.D.=12.1230 inches (307.9242 mm)Minimum O.D.=12.1190 inches (307.8226 mm)Nominal I.D.=11.3130 inches (287.3502 mm)Nominal Wall Thickness=0.4050 inches (10.2870 mm)Flow Area=100.5184 sq. inches (64850.43 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)10000.110.263.19630870.030.260.97 12000.160.373.83757040.040.371.17 14000.210.494.47883210.050.491.36 16000.270.625.111009390.060.621.56 18000.340.775.751135560.080.771.75 20000.410.946.381261730.090.941.95 22000.491.127.021387910.111.122.14 24000.571.327.661514080.131.322.33 26000.671.538.301640250.151.532.53 28000.761.758.941766430.171.752.72 30000.871.999.581892600.201.992.92 32000.982.2510.212018770.222.253.11 34001.092.5110.852144950.252.513.31 36001.222.7911.492271120.282.793.50 38001.343.0912.132397290.303.093.70 40001.483.3912.772523470.333.393.89 42001.623.7113.412649640.373.714.09 44001.764.0514.042775810.404.054.28 46001.924.3914.682901990.434.394.48 48002.074.7515.323028160.474.754.67 50002.245.1315.963154330.515.134.86 52002.405.5116.603280510.545.515.06 54002.585.9117.243406680.585.915.25 56002.766.3217.873532850.626.325.45 58002.946.7518.513659030.676.755.64 60003.137.1819.153785200.717.185.84 62003.337.6319.793911370.757.636.03 12" TYPE “L” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=12.1270 inches (308.0258 mm)Nominal O.D.=12.1230 inches (307.9242 mm)Minimum O.D.=12.1190 inches (307.8226 mm)Nominal I.D.=11.5630 inches (293.7002 mm)Nominal Wall Thickness=0.2800 inches (7.1120 mm)Flow Area=105.0101 sq. inches (67748.29 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)10000.100.233.06630870.020.230.93 12000.140.333.67757040.030.331.12 14000.190.444.28883210.040.441.30 16000.240.564.891009390.060.561.49 18000.300.705.501135560.070.701.68 20000.370.856.111261730.080.851.86 22000.441.016.721387910.101.012.05 24000.521.197.331514080.121.192.23 26000.601.377.941640250.141.372.42 28000.691.588.551766430.161.582.61 30000.781.799.171892600.181.792.79 32000.882.029.782018770.202.022.98 34000.982.2610.392144950.222.263.17 36001.092.5111.002271120.252.513.35 38001.212.7711.612397290.272.773.54 40001.333.0512.222523470.303.053.72 42001.463.3412.832649640.333.343.91 44001.593.6413.442775810.363.644.10 46001.723.9514.052901990.393.954.28 48001.864.2714.673028160.424.274.47 50002.014.6115.283154330.454.614.66 52002.164.9615.893280510.494.964.84 54002.325.3116.503406680.525.315.03 56002.485.6817.113532850.565.685.21 58002.656.0717.723659030.606.075.40 60002.826.4618.333785200.646.465.59 62002.996.8618.943911370.686.865.77 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 83 12" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D.=12.1270 inches (308.0258 mm)Nominal O.D.=12.1230 inches (307.9242 mm)Minimum O.D.=12.1190 inches (307.8226 mm)Nominal I.D.=11.6150 inches (295.021 mm)Nominal Wall Thickness=0.2540 inches (6.4516 mm)Flow Area=105.9567 sq. inches (68359.01 sq. mm)Hazen Williams FormulaC Factor=150 FLOW, QPressure LossHead LossVelocityFLOW, QPressure LossHead LossVelocity (GPM)(psi/100 ft)(ft/100 ft)(ft./sec.)(cu. cm/sec.)(kPa/100 m)(m/100 m)(m/sec.)10000.100.233.03630870.020.230.92 12000.140.323.63757040.030.321.11 14000.190.434.24883210.040.431.29 16000.240.554.841009390.050.551.48 18000.300.685.451135560.070.681.66 20000.360.836.061261730.080.831.85 22000.430.996.661387910.100.992.03 24000.511.167.271514080.111.162.22 26000.591.357.871640250.131.352.40 28000.671.548.481766430.151.542.58 30000.761.759.081892600.171.752.77 32000.861.989.692018770.191.982.95 34000.962.2110.302144950.222.213.14 36001.072.4610.902271120.242.463.32 38001.182.7111.512397290.272.713.51 40001.302.9812.112523470.292.983.69 42001.423.2712.722649640.323.273.88 44001.553.5613.322775810.353.564.06 46001.683.8713.932901990.383.874.25 48001.824.1814.533028160.414.184.43 50001.974.5115.143154330.444.514.61 52002.114.8515.753280510.484.854.80 54002.275.2016.353406680.515.204.98 56002.435.5616.963532850.555.565.17 58002.595.9317.563659030.595.935.35 60002.766.3218.173785200.626.325.54 62002.936.7118.773911370.666.715.72 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 84 Copper Water Tube continued COPPER TUBE – TYPES, STANDARDS, APPLICATIONS, TEMPERS AND LENGTHS Commercially Available Lengths Tube TypeColor CodeStandardApplicationNominal or Standard SizesDrawnAnnealed Type KGreenASTM B 88Domestic Water Service DistributionStraight Lengths:1 /4 -inch to 8-inch20 ft. (6.1m)20 ft. (6.1m)Fire Protection10-inch18 ft. (5.5m)18 ft. (5.5m)Solar12-inch12 ft. (3.7m)12 ft. (3.7m)Fuel/Fuel OilCoils:1 /4 -inch to 1-inch–60 ft. (18.3m)HVAC–100 ft. (30.5m)Snow Melting1 1 /4 -inch & 1 1 /2 -inch –60 ft. (18.3m)2-inch–40 ft. (12.2m)–45 ft. (13.7m)Type LBlueASTM B 88Domestic Water Service DistributionStraight Lengths:1 /4 -inch to 10-inch20 ft. (6.1m)20 ft. (6.1m)Fire Protection12-inch18 ft. (5.5m)18 ft. (5.5m)Solar Fuel/Fuel Oil Natural GasCoils:1 /4 -inch to 1-inch–60 ft. (18.3m)Liquified Petroleum (LP) Gas–100 ft. (30.5m)HVAC1 1 /4 -inch & 1 1 /2 -inch –60 ft. (18.3m)Snow Melting2-inch–40 ft. (12.2m)–45 ft. (13.7m)Type MRedASTM B 88Domestic Water Service DistributionStraight Lengths:1 /4 -inch to 12-inch20 ft. (6.1m)N/A Fire Protection Solar Fuel/Fuel Oil HVAC Snow Melting DWVYellowASTM B 306DrainStraight Lengths:1 1 /4 -inch to 8-inch20 ft. (6.1m)N/A Waste Vent HVAC Solar ACRBlueASTM B 280Air ConditioningStraight Lengths:1 /4 -inch to 4 1 /8 -inch20 ft. (6.1m)20 ft. (6.1m)1 Refrigeration Natural GasCoils:1 /8 -inch to 1 5 /8 -inch–50 ft. (15.3m)1 Liquified Petroleum (LP) Gas OXYType KASTM B 819Medical GasStraight Lengths:1 /4 -inch to 8-inch20 ft. (6.1m)N/A MEDGreen OXY/MED OXY/ACRType L ACR/MEDBlue Type GYellowASTM B 837Natural GasStraight Lengths:3 /8 -inch to 1 1 /8 -inch12 ft. (3.7m)12 ft. (3.7m)1 Liquified Petroleum (LP) Gas20 ft. (6.1m)20 ft. (6.1m)1 Coils:3 /8 -inch to 7 /8 -inch–60 ft. (18.3m)1 –100 ft. (30.5m)1 1 Available as special order only.U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. The Fine Art of Soldering AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 85 1.Cut tube end square, ream, burr and size.When adjoining surfaces of copper and copper alloys meet under proper conditions of cleanliness and temperature,solder will make a perfect adhesion. The strength of joint is equal to or even greater than the strength of tube alone.Surface tension seals the joint. Capillary attraction draws solder into, around, and all about the joint. It’s easy to learn to make a perfect solder joint when you use NIBCO Fittings.WITH 95-5 SOLDER AND INTERMEDIATELY CORROSIVE FLUX 6.Remove excess solder with a small brush or wiping cloth while the solder is plastic.2.Use sand cloth or steel wire brush to clean tube and cup to a bright metal finish.3.Apply solder flux to outside of tube and inside of cup of fitting carefully so that surfaces to be joined are completely covered. Use flux sparingly.4.Apply flame to the fitting to heat tube and solder cup of fitting until solder melts when placed at joint of tube and fitting.5.Remove flame and feed solder into the joint at one or two points until a ring of solder appears at the end of the fitting.The correct amount of solder is approximately equal to 1 1 /2 the diameter of the fitting… 3 /4 " (20mm) solder for 1 /2 " fitting, etc. 1.The tube should be cut to desired length with a square cut,preferably in a square-end sawing vise. The cutting wheel of the type specifically designed for cutting copper tube will also do a satisfactory job. The tube should be the exact length needed, so that the tube will enter the cup of the fitting all the way to the shoulder of the cup. Remove all slivers and burrs left from cutting the tube, by reaming and filing, both inside and outside.2.To make a proper brazing joint, the clearance between the solder cup and the tube should be approximately 0.001" to 0.010"(0.0254mm to 0.254mm). Maintaining a good fit on parts to be brazed insures:Ease of Application — Excessively wide tolerances tend to break capillary force; and, as a result the alloy will either fail to flow throughout the joint or may flush out of the joint.Corrosion Resistance — There is also a direct relation between the corrosion resistance of a joint and the clearance between members.Economy — If brazing alloys are to be used economically, they, of necessity, must be applied in the joint proper and in minimum quantities, using merely enough alloy to fill the area between the members.3.The surfaces to be joined must be clean and free from oil,grease and heavy oxides. The end of the tube need be cleaned only for a distance slightly more than it is to enter the cup. Special wire brushes designed to clean tube ends may be used, but they should be carefully used so that an excessive amount of metal will not be removed from the tube. Fine sand cloth or emery cloth may also be used with the same precautions. The cleaning should not be done with steel wool, because of the likelihood of leaving small slivers of the steel or oil in the joint.4.The cup of the fitting should be cleaned by methods similar to those used for the tube end, and care should be observed in removing residues of the cleaning medium. Attempting to braze a contaminated or an improperly cleaned surface will result in an unsatisfactory joint. Brazing alloys will not flow over or bond to oxides; and oily or greasy surfaces tend to repel fluxes,leaving bare spots which will oxidize, resulting in voids and inclusions.5.Flux should be applied to the tube and solder cup sparingly and in a fairly thin consistency. Avoid flux on areas not cleaned.Particularly avoid getting excess flux into the inside of the tube itself. Flux has three principal functions to perform:A.It prevents the oxidation of the metal surfaces during the heating operation by excluding oxygen.B.It absorbs and dissolves residual oxides that are on the surface and those oxides which may form during the heating operation.C.It assists in the flow of the alloy by presenting a clean nascent surface for the melted alloy to flow over. In addition, it is an excellent temperature indicator, especially if an indicating flux is used.6.Immediately after fluxing, the parts to be brazed should be assembled. If fluxed parts are allowed to stand, the water in the flux will evaporate, and dried flux is liable to flake off, exposing the metal surfaces to oxidation from the heat. Assemble the joint by inserting the tube into the cup, hard against the stop. The assembly should be firmly supported so that it will remain in alignment during the brazing operation.AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 86 The Fine Art of Brazing Best results will be obtained by a skilled operator employing the step-by-step brazing technique that follows: AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 87 7.Brazing is started by applying heat to the parts to be joined. The preferred method is by the oxyacetylene flame. Propane and other gases are sometimes used on smaller sizes. A slightly reducing flame should be used, with a slight feather on the inner blue cone;the outer portion of the flame, pale green. Heat the tube first,beginning at about one inch from the edge of the fitting. Sweep the flames around the tube in short strokes up and down at right angles to the run of the tube. It is very important that the flame be in continuous motion and should not be allowed to remain on any one point to avoid burning through the tube. Generally, the flux may be used as a guide as to how long to heat the tube, continuing heating after the flux starts to bubble or work, and until the flux becomes quiet and transparent, like clear water. The flux will pass through four stages:A.At 212°F (100°C) the water boils off.B.At 600°F (315.6°C) the flux becomes white and slightly puffy and starts to work.C.At 800°F (426.7°C) it lays against the surface and has a milky appearance.D.At 1100°F (593.3°C) it is completely clear and active and has the appearance of water.8.Now switch the flame to the fitting at the base of the cup. Heat uniformly,sweeping the flame from the fitting to the tube until the flux on the fitting becomes quiet.Avoid excessive heating of cast fittings.9.When the flux appears liquid and transparent on both the tube and the fitting, start sweeping the flame back and forth along the axis of the joint to maintain heat on the parts to be joined, especially toward the base of the cup of the fitting. The flame must be kept moving to avoid burning the tube or the fitting.10.Apply the brazing wire or rod at a point where the tube enters the socket of the fitting. The temperature of the joint should be hot enough to melt the brazing alloy. Keep the flame away from the rod or wire as it is fed into the joint. Keep both the fitting and the tube heated by moving the flame back and forth from one to the other as the alloy is drawn into the joint. When the proper temperature is reached, the alloy will flow readily into the space between the tube outer wall and the fitting socket, drawn in by the natural force of capillary attraction. When the joint is filled, a continuous fillet of brazing alloy will be visible completely around the joint. Stop feeding as soon as the joint is filled, using table on page 54 as a guide for the alloy consumption.NOTE: For tubing one inch and larger, it is difficult to bring the whole joint up to heat at one time. It frequently will be found desirable to use a double-tip torch to maintain the proper temperature over the larger area. A mild pre-heating of the whole fitting is recommended. The heating then can proceed as in steps 7, 8,9, and 10. If difficulty is encountered in getting the whole joint up to heat at one time, then when the joint is nearly up to the desired temperature the alloy is concentrated in a limited area. At the brazing temperature the alloy is fed into the joint and the torch is then moved to an adjacent area and the operation carried on progressively all around the joint.HORIZONTAL JOINTS — When making horizontal joints, it is preferable to start applying the brazing alloy at the 5 o’clock position, then move around to the 7 o’clock position and then move up the sides to the top of the joint, making sure that the operations overlap.VERTICAL JOINTS — On vertical joints, it is immaterial where the start is made. If the opening of the cup is pointed down, care should be taken to avoid overheating the tube, as this may cause the alloy to run down the tube. If this condition is encountered, take the heat away and allow the alloy to set. Then reheat the solder cup of the fitting to draw up the alloy.After the brazing alloy has set,remove residual flux from the joint area as it is corrosive and presents an unclean appearance and condition. Hot water or steam and a soft cloth should be used. Wrot fittings may be chilled; however it is advisable to allow cast fittings to cool naturally to some extent before applying a swab. All flux must be removed before inspection and pressure testing.TROUBLE SPOTS If the alloy fails to flow or has a tendency to ball up, it indicates oxidation on the metal surfaces, or insufficient heat on the parts to be joined. If work starts to oxidize during heating, it indicates too little flux, or a flux of too thin consistency. If the brazing alloy refuses to enter the joint and tends to flow over the outside of either member of the joint, it indicates this member is overheated, or the other is underheated, or both. In both cases, operations should be stopped and the joints disassembled, recleaned and fluxed. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 88 FITTING SYSTEM – INSERT/CRIMP TYPE*Making a Connection Polyethylene (PEX) Tubing *NIBCO recommends the use of copper crimp rings ONLY and a properly calibrated full circle crimping tool for joining PEX tubing and copper barbed fittings.2.Slide copper crimp ring on tubing.3.Insert ribbed fitting into tubing until tubing contacts the fitting shoulder (tube stop). Position the crimp ring on the tubing so that the edge of the ring is 1/8" to 1/4" (3 to 6mm) from the end of the tube.4.Center the crimping tool jaws exactly over the ring while maintaining its position relative to the fitting. Crimp the ring by closing the handles together to the positive stop on the tool. Check the after-crimped diameter of each ring with the crimp gauge. If the small flats on the gauge do not fit over the crimped ring, the ring is under-crimped. Cut out any under-crimped rings and fittings and completely replace. DO NOT RE-CRIMP.1.Using a tube cutter, cut tubing squarely and remove burrs. AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 89 FITTING SYSTEM – INSERT/CRIMP TYPE MADE BY NIBCO Making a Connection Polybutylene Tubing TOOLS AND RINGS •Use tools recommended by fitting and tubing manufacturers. All tools must make a full-circle crimp.•Check tool adjustment at least daily, and readjust as necessary.•Use crimp rings of copper as recommended by NIBCO INC.2.Slide copper crimp ring on tubing. Only copper crimp rings should be used to ensure the highest quality connection.3.Insert fitting into tubing, then position crimp ring squarely over barbs. Proper alignment is important for making the best connection.4.Center the crimping tool jaws exactly over the ring, and bring the tool handles together until totally closed to the stop indicator. Check each crimp ring with the caliper gauge after completion. If the small flats on the gauge do not fit over the crimped ring, the ring is undercrimped. Cut out any undercrimped rings and fittings,and completely replace.1.Using a tube cutter,cut tubing squarely and remove burrs. Frequently Asked Questions Q:What is the pressure rating of a given fitting?A:Fittings are rated per Table 1 of ASME B16.22. The system rated pressure shall be the lowest of the fitting, tube or joint.Q:When copper fails in a system, what is the problem?A:MOST COMMON:1.Velocity – fluid is moving too fast. Recommendation: 2-3 fps (0.0508-0.0762 m/s) hot water 140°F, 5-8 fps (0.127-0.2032 m/s) cold water. Refer to pages 68-93.2.Turbulence – burrs left on the cut tubing causes a tumbling effect causing localized erosion and eventual failure.3.Aggressive Waters – tend to cause pitting or green staining of fixtures. Aggressive, hard well waters that cause pitting typically are found to have total dissolved solids including suflates and chlorides, a pH in the range of 7.2 to 7.8, a high content of carbon dioxide gas and the pressence of dissolved oxygen gas. Soft acidic waters that cause green staining typically tend to be more corrosive. Low alkalinity, low mineralization, pH levels of 7 or lower should be avoided.LESS COMMON:1.Flux Corrosion – using too much flux when making joints can potentially leave residue and cause isolated corrosion. Flux should be used sparingly and system adequately flushed.2.Electrolysis – stray (D.C.) current; inadequate grounding for the piping.3.Sand or other solid particulates – erosion/corrosion problems can occur. Lower velocities must be maintained if solids are present in flow media.4.Galvanic Corrosion – destruction of a material by electrochemical interaction between the environment and the material.Q:Copper tubing wall thickness is designated “K,” “L” or “M.” What are the copper fittings applicable to?A:Copper fittings’ wall thickness is determined by standards (ASME B-16:22 and MSS-SP-104). These standards address minimum wall thickness (per size) for the full range of copper fittings and are not intended to match tubing wall thicknesses.Q:Can dissimilar metals (i.e., copper and iron) be joined together without use of dielectric insulators to prevent corrosion?A:In most situations dissimilar metals (copper/iron/steel) can be joined successfully without using dielectric insulators. Factors to consider:1.The composition of the two metals.2.The rate of liquid flow past the two metals.3.Chemicals in the water which could enhance or destroy protective films.4.The relative areas of the two metals - unless the surface area of the less noble (steel) material is less that 5% of the more noble (copper) material, the need for a dielectric separator is not needed. (Failures due to galvanic corrosion are very unusual and only occur under very strict conditions.)5. Local code requirements.Q:What should the installer of copper unions know and do in order to assure a proper leak-free installation?A.The following should be done:1.Make sure the ground-joint(mating area of unionís tail and thread pieces) are free of nicks and scratches.2.Spray the ground-joint area with a food grade silicone spray or apply bees wax to enhance seating.3.Make sure alignment of line does not put lateral stress on the ground-joint seal.4.Make sure that excess solder (droplets) do not reach the ground-joint area.AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 90 Residential Copper Plumbing Products Limited Warranty What the warranty terms mean In this warranty “Manufacturer” refers to the company listed below which manufactured the Product and any person or company that assumes its obligations under this warranty. “Homeowner” means you as the owner of the residential building in the United States in which the Product has been installed and also means any succeeding owner during the original warranty term. “Product” means the copper water tube and/or copper or brass fittings manufactured by the Manufacturer for the residential building market in the United States.Each Manufacturer listed below separately and individually warrants only Products it has manufactured and does not warrant Products of any other company, whether or not listed below.Date the warranty begins The warranty begins on the date of the new home purchase, or in the case of home additions or renovations, on the date the installation is completed. The warranty is transferable to succeeding Homeowners for the remainder of the original warranty term, in which case the date the warranty begins shall continue without change.What is covered The Manufacturer warrants to the Homeowner for a period of 50 years from the date the warranty begins that its properly installed Product will be free of failure as a result of defects in material or workmanship in manufacturing the Product.What the manufacturer will do for you As long as (1) such a failure occurs within 50 years from the date the warranty begins and (2) the Homeowner promptly notifies the Manufacturer of the Product of that failure by contacting it through its 800 phone number listed below, the Manufacturer will correct that failure by repairing or replacing the Product within a reasonable time,without charge. This warranty is limited to the cost of repairing or replacing the Product, including installation.NIBCO TECHNICAL SERVICE 1-888-446-4226 What is not covered: Disclaimer of liability for consequential and other damages The Manufacturer does NOT warrant against failure:1.of any product, parts, or systems that it has not manufactured;2.if the Product is used for purposes other than residential plumbing applications;3.caused by, contributed in whole or in part by, or resulting from,any of the following:(a)improper installation;(b)abuse, such as, without limitation, vandalism;(c)natural disasters, such as, without limitation, flooding,windstorm and lightning;(d)attachments or modifications to the Product that the Manufacturer did not authorize;(e)external causes, where external, physical or chemical qualities produce damage to the Product, such as, without limitation, aggressive water or an unsuitable or hostile environment; or (f)any other cause beyond the Manufacturer’s control.The Manufacturer shall NOT be liable under any circumstances for any other direct or any indirect, incidental or consequential damages of any kind.This is the only warranty This warranty is the only warranty for the Product provided by the Manufacturer, and is and shall be in lieu of any and all other warranties, express or implied, including but not limited to an implied warranty of merchantability, and of all other obligations or liabilities on the part of the Manufacturer. None of the Manufacturer’s employees, and no other person or business, is authorized to make any other warranty on the Manufacturer’s behalf covering the product.This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 91 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 92 Numerical Index Figure NumberPage Figure NumberPage Figure NumberPage Figure NumberPage Figure NumberPage 100 Series Cast Heavy Flared 101...............................23 104...............................23 500 Series Cast Flared 500..............................24 503..............................23 504..............................23 507..............................23 507-3...........................23 507-4...........................23 511...............................24 600 Series Wrot Pressure 600................................9 600-2...........................15 600-DS........................10 600-RS .........................9 601..............................10 603................................6 603-2.............................6 604................................7 604-2.............................7 606..............................11 606-2...........................11 607..............................12 607-2...........................13 607-2-2........................13 607-2-2-LT....................13 607-2-I.........................13 607-2-LT.......................13 607-I............................12 607-LT..........................12 611.........................17-19 611-2............................19 616..............................16 617................................9 618................................8 618-3.............................8 619 ...............................8 620-L ............................8 621..............................21 623..............................16 624..............................16 633-W.........................21 638..............................16 698..............................20 700 Series Cast Pressure 701..............................10 701-D...........................10 702 .............................10 703................................6 703-2.............................6 703-5 ............................6 703-5B ..........................6 704................................7 704-2.............................7 704-2-H.........................8 704-F.............................7 704-H............................7 705..............................16 705-D...........................17 706-2...........................12 707..............................12 707-2-4........................13 707-3...........................14 707-3-5........................14 707-3-5-A....................14 707-3-6........................14 707-4...........................14 707-4-6........................14 707-5...........................14 707-5-A........................14 707-6...........................15 708..............................15 710-3...........................17 710-3-4........................17 711..............................19 711-5...........................19 711-A...........................19 712..............................20 712-5...........................20 713 .............................20 714..............................20 717................................9 717-D.............................9 718-3.............................8 724-5-A ......................10 733..............................21 733-2...........................21 733-3...........................21 733-4...........................21 735..............................11 736 .............................11 739..............................16 741...............................15 748 .............................21 749 .............................21 750................................8 750-3.............................8 750-4.............................8 764..............................15 771..............................16 775..............................16 800 Series Cast DWV 801..............................34 801-2...........................33 801-2-7........................31 801-T............................32 802..............................32 802-C...........................32 802-F...........................32 803..............................32 803-2...........................32 804..............................32 804-2...........................33 804-T...........................33 805..............................31 805-N..........................31 806..............................35 806-2...........................35 807..............................35 807-2...........................35 807-3...........................36 807-4...........................36 807-9...........................36 808..............................36 809..............................36 810..............................38 811..............................37 811-14..........................37 811-15..........................37 812..............................38 814..............................38 816..............................33 816-S...........................33 818 A.S.A....................36 834..............................38 835..............................37 835-B...........................37 836..............................38 837..............................36 851..............................34 851-C...........................34 861-LH.........................36 875-S...........................40 878..............................40 879..............................40 880..............................39 881..............................39 884..............................39 885..............................39 890..............................39 891..............................39 892..............................39 892-3...........................39 892-A...........................39 900 Series Wrot DWV 901..............................34 901-2...........................33 901-2-7........................31 901-2-F........................33 901-7............................31 901-RP.........................34 903..............................32 903-2...........................32 903-7...........................31 904..............................33 904-7...........................31 905..............................31 906..............................35 906-2...........................35 907..............................35 907-2...........................35 907-LT..........................35 911..............................37 917-B...........................37 951..............................34 960..............................36 Copper Insert Fittings for Polybutylene PB198..........................29 PB600..........................29 PB600-FA....................29 PB607..........................29 PB607-FA.....................29 PB611..........................29 Copper Insert Fittings for Polyethylene (PEX)PEX198.........................26 PEX600.........................26 PEX600.........................26 PEX600-2......................26 PEX600-FA...................26 PEX600-T......................26 PEX603.........................26 PEX604.........................26 PEX607.........................26 PEX607-FA...................26 PEX611.........................26 PEX707-3-5..................26 PEX841.........................27 PEX100.........................27 PEX6I6..........................27 AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 93 NOTES AHEADOFTHEFLOW ™w w w w w w ..n n i i b b c c o o ..c c o o m m R R e e v v i i s s i i o o n n 5 5 //1 1 4 4 //0 0 2 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 94 NOTES NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH:1.888.446.4226 • FAX: 1.800.336.4226 • INTERNATIONALOFFICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com It’s a new age of business, and a new way at NIBCO. From Elkhart,Indiana to Lodz, Poland,and points beyond, our company has integrated manufacturing, distribu-tion, and networked communica-tions to provide a seamless source of information and service, 24 hours a day, 7 days a week. But this integration hasn’t hap-pened overnight. It’s been part of a long-term strategic process that has pushed us to reconsid-er every aspect of our business.The result? We’re a vertically integrated manufacturer with the products and systems in place to deliver low cost and high quality. NIBCO’s products are manufactured under a Quality Management System conforming to the current revi-sion of ISO-9001 International Standards. We know the flow control industry is only going to get more demanding, and we are more than ready. We will continue to lead. That’s what NIBCO is all about.globally connecting you at all levels World Headquarters Elkhart, Indiana Metal Valves and Fittings Blytheville, Arkansas McAllen, Texas Nacogdoches, Texas South Glens Falls,New York Stuarts Draft, Virginia Plastic Pipe, Valves, and Fittings Greensboro,Georgia Goshen,Indiana Denmark, South Carolina Industrial Plastics Charlestown, Indiana International Lodz, Poland Reynosa, Mexico U.S. & International Distribution Centers Atlanta, Georgia Charlestown,Indiana Columbus, Ohio Lodz, Poland Los Angeles,California Global Offices Elkhart, Indiana Lodz, Poland Vilnilus, Lithuania MANUFACTURING DISTRIBUTION INTERNATIONAL Pipe Hangers & Support Systems Corona,California C-CF-0404 © 2004, NIBCO INC.Printed in USA NIBCO INC.WORLD HEADQUARTERS WEB: www.nibco.com 1516 MIDDLEBURY STREET ELKHART, IN 46516-4740 USA DOMESTIC CUSTOMER SERVICE PHONE: 800.234.0227 FAX: 800.234.0557 TECHNICAL SERVICE PHONE: 888.446.4226 FAX: 888.336.4226 INTERNATIONAL OFFICE PHONE: +1/574.295.3221 FAX: +1/574.295.3455 FITTINGS VALVES & ACTUATION CHEMTROL ®TOLCO ™NIBCO ®now offers complete support with its newest addition of TOLCO ™brand piping solutions including: Pipe attachments• Structural attachments• Pipe rollers • Threaded products and accessories • Seismic components •Vibration isolation • Standard and specialty supports • TOL-Strut ™channel and components.Pressure-rated bronze, iron and alloy-iron gate, globe and check valves • Pressure-rated bronze ball valves • Boiler specialty valves • Commercial and industrial butterfly valves • Circuit balancing valves • Carbon and stainless steel ball valves •ANSI flanged steel ball valves • Pneumatic and electric actuators and controls • Grooved ball and butterfly valves • High performance butterfly valves • UL/FM fire protection valves • MSS specification valves • Bronze specialty valves • Low- pressure gate, globe, check and ball valves • Frostproof sillcocks • Quarter--turn supply stops • PVC ball valves • CPVC CTS ball valves • Just Right ®recirculating valves.Thermoplastic pipe, valves and fittings in PVC, Corzan ®CPVC, polypropylene and PVDF Kynar ®• Chem-Aire ®thermoplastic compressed air piping systems • Pneumatic and electric actuation systems.Wrot and cast copper pressure fittings • Wrot and cast copper drainage fittings • Wrot copper PEXlink ®fittings • Cast copper alloy flared fittings • Cast copper alloy flanges • ABS and PVC DWV fittings • Schedule 40 PVC pressure fittings • CPVC CTS fittings • CPVC CTS-to-metal transition fittings • Schedule 80 PVC and CPVC systems • CPVC metric piping systems.Corzan ® is a registered trademark of Noveon, IP Holdings Corp. Kynar ®is a registered trademark of ATOFINAChemicals, Inc.eNIBCO A suite of services designed to make customers more efficient •More cost--effective • More informed • EDI—Electronic Data Interchange •VMI—Vendor Managed Inventory •NIBCO.com •NIBCOpartner.com •eNIBCO will continuously develop new products to deliver the competitive advantage.C-CF-0404 AHEADOFTHEFLOW ™w w w .n i b c o .c o m R e v i s i o n 5 /1 4 /0 2 NIBCO INC. WORLDHEADQUARTERS • 1516 MIDDLEBURYST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECHSERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONALSERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 52 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents.Copper Water Tube continued DIMENSIONAL DATA – COPPER WATER TUBE – TYPE “M”TYPE “M”Hard Drawn Only:20-ft. (6.1m) Straight Lengths Usage:For general purpose plumbing, heating and drainage installations.TolerancesHard Drawn (Hard Drawn Only)OutsideTubing ODNominal WallWeightBurstingSafe Working NominalDiameterThicknessPer FootPressure A Pressure B Water TubeMin.Max.Size (In Inches)Inch(mm)Inch(mm)Inch(mm)Inch(mm)Lb(kg)psi(bars)psi(bars)1/40.375(9.53)0.373(9.47)0.376(9.55)N/AN/AN/AN/AN/AN/AN/AN/A 3/80.500(12.70)0.497(12.62)0.501(12.73)0.025(0.64)0.145(0.07)N/AN/A855 (59)1/20.625(15.88)0.622(15.80)0.626(15.90)0.028(0.71)0.204(0.09)6135 (423)741 (51)5/80.750(19.05)0.747(18.97)0.751(19.08)N/AN/AN/AN/AN/AN/AN/AN/A 3/40.875(22.23)0.872(22.15)0.876(22.25)0.032(0.81)0.328(0.15)4717 (325)611 (42)11.125(28.58)1.122(28.50)1.127(28.63)0.035(0.89)0.465(0.21)3865 (266)506 (35)1 1/41.375(34.93)1.372(34.85)1.377(34.98)0.042(1.07)0.682(0.31)3875 (267)507 (35)1 1/21.625(41.28)1.621(41.17)1.627(41.33)0.049(1.24)0.940(0.43)3550 (245)497 (34)22.125(53.98)2.121(53.87)2.127(54.03)0.058(1.47)1.460(0.66)2935 (202)448 (31)2 1/22.625(66.68)2.621(66.57)2.627(66.73)0.065(1.65)2.030(0.92)2800 (193)411 (28)33.125(79.38)3.121(79.27)3.127(79.43)0.072(1.83)2.680(1.22)2665 (184)380 (26)3 1/23.625(92.08)3.621(91.97)3.627(92.13)0.083(2.11)3.580(1.62)N/AN/A378 (26)44.125(104.78)4.121(104.67)4.127(104.83)0.095(2.41)4.660(2.11)2215 (153)377 (26)55.125(130.18)5.121(130.07)5.127(130.23)0.109(2.77)6.660(3.02)2490 (172)349 (24)66.125(155.58)6.121(155.47)6.127(155.63)0.122(3.10)8.920(4.05)2000 (138)328 (23)88.125(206.38)8.119(206.22)8.127(206.43)0.170(4.32)16.500(7.48)2285 (158)344 (24)1010.125(257.18)10.119(257.02)10.127(257.23)0.212(5.38)25.600(11.61)N/AN/A344 (24)1212.125(307.98)12.119(307.82)12.127(308.03)0.254(6.45)36.700(16.65)N/AN/A345 (24)Note: Information and data contained in these charts, as taken from ASTM Specifications B 88. Rated internal pressure for copper water tube based on the strength of the tube alone and applicable to systems using suitable mechanical joints.A Based on actual laboratory test data provided by Copper Development Association, Inc.B Based upon 150°F (65.6°C) with an allowable stress of 9500 psi (668 kPa). OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 84 www.tolco.com Revision 5/24/2001 ™®a brand of www.tolco.com Revision 5/24/2001 Fig. 200 - “Trimline” Adjustable Band Hanger Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation.Features — • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe.• (2 1 ⁄2 " thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed.Approvals — Underwriters’ Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10.Maximum Temperature — 650°F Finish — Mil. Galvanized. For Stainless Steel materi-als, order TOLCO™ Fig. 200WON.Order By — Figure number and pipe size Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 3 1 ⁄8 2 5 ⁄8 400 11 3/4 3/8 8mm or 10mm 3 1 ⁄8 2 1 ⁄2 400 11 1 3/8 8mm or 10mm 3 3 ⁄8 2 5 ⁄8 400 12 1 1 ⁄4 3/8 8mm or 10mm 3 3 ⁄4 2 7 ⁄8 400 13 1 1 ⁄2 3/8 8mm or 10mm 3 7 ⁄8 2 7 ⁄8 400 14 2 3/8 8mm or 10mm 4 1 ⁄2 3 400 15 2 1 ⁄2 3/8 10mm 5 5 ⁄8 4 1 ⁄8 600 27 3 3/8 10mm 5 7 ⁄8 4 600 29 3 1 ⁄2 3/8 10mm 7 3 ⁄8 5 1 ⁄4 600 34 4 3/8 10mm 7 3 ⁄8 5 1000 35 5 1/2 12mm 9 1 ⁄8 6 1 ⁄4 1250 66 6 1/2 12mm 10 1 ⁄8 6 3 ⁄4 1250 73 8 1/2 12mm 13 1 ⁄8 8 3 ⁄4 1250 136 4 For the most up to date information, visit www.itwbuildex.com Wood Flooring Wood Joist Double Sheetrock Ceiling Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs)UL Test Load (lbs)FM Test Load (lbs)Box Qty Case Qty VERTICAL MOUNT 1/4"8002957 GST 100 1/4 x 1"210 (7/16” OSB)670 (3/4” Ply)25 125 1/4"8003957 GST 200 1/4 x 2"1760 (Fir)25 125 1/4"8004957 GST 300 1/4 x 3"2060 (Fir)25 125 3/8"8007957 GST 10 1/4 x 1"210 (7/16” OSB)670 (3/4” Ply)300 25 125 3/8"8008957 GST 20 1/4 x 2"1760 (Fir)850 1475 25 125 3/8"8068925 GST 20-SS 1/4 x 2"1760 (Fir)850 25 125 3/8"8009925 GST 25-380 3/8 x 2-1/2"2113 (Fir)1500 25 125 3/8"8010957 GST 30 1/4 x 3"2060 (Fir)1500 1475 25 125 3/8"8069925 GST 30-SS 1/4 x 3"2060 (Fir)25 125 3/8"8011925 GST 40 1/4 x 4"2180 (Fir)25 125 1/2"8013925 GST 2 1/4 x 2"1760 (Fir)25 125 1/2"8014925 GST 2.5-380 3/8 x 2-1/2"2113 (Fir)25 125 1/2"8015925 GST 3 1/4 x 3"2275 (Fir)25 125 Not less than 2” nominal width (1-1/2”)Not less than 3” nominal thickness (2-1/2”) (depth or side of vertical member)#14 Black Nut Driver Part # 8113910 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. W arranty requires the use of the appropriate nut driver for installations.#14 SW Red Nut Driver Part # 8114910 Composite / Truss Consult truss manufacturer for recommended installation point.*Pre-drilling may be required for GST 25-380 . Tool available on page 11.For vertical use - install in center of lower face.Minimum 2” embedment into base material for NFPA 13 compliance.• No pre-drilling required.• Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver.• Saves time from traditional methods.• Reduces installation costs.• Made in the U.S.A.SAMMYS ® FOR WOOD Application Product Features Watch a video demonstration at www.itwbuildex.com SAMMYS ® FOR WOOD - Vertical Application