Project Name: MIDDLE CREEK BBQ AREA DRB Number: DR6120248
Project Description:
BUILDING BBQ AREA FOR APARTMENT COMMUNITY.
Participants:
OWNER TOWN OF VAIL 06/22/2012
75SFRONTAGERDW
VAI L
CO 81657
APPLICANT COUGHLIN AND COMPANY 06/22/2012 Phone: 303-863-1900
140 E 19TH AVENUE
SUITE 700
DENVER
CO 80203
Project Address: 129 N FRONTAGE RD W VAIL Location:
MIDDLE CREEK VILLAGE
Legal Description: Lot: 1 Block: Subdivision: MIDDLE CREEK
Pa rcel N u m ber: 2101-064-0900-1
Comments: See conditions
BOARD/STAFF ACTION
Motion By: Action: STAFFAPP
Second By:
Vote: Date of Approval: 07/05/2012
Conditions:
Cond: 8
(PLAN): No changes to these plans may be made without the written consent of Town of
Vail staff and/or the appropriate review committee(s).
Cond: 0
(PLAN): DRB approval does not constitute a permit for building. Please consult with
Town of Vail Building personnel prior to construction activities.
Cond: 201
(PLAN): DRB approval shall not become valid for 20 days following the date of
approval, pursuant to the Vail Town Code, Chapter 12-3-3: APPEALS.
Cond: 202
(PLAN): Approval of this project shall lapse and become void one (1) year following
the date of final approval, unless a building permit is issued and construction is
commenced and is diligently pursued toward completion.
Cond: CON0012668
The applicant shall comply with Section 308.1.4, Open Flame Cooking Devices, 2009
International Building Code, requiring that the charcoal grills be a minimum of 10
feet from combustible construcution when locating the improvements.
Cond: CON0012669
The applicant shall locate the pad for the new grilling area a minimum of ten feet
to the north of the exisitng aspen trees located along the change in slope from the
flat area to the downhill sloping portion of the site.
Cond: CON0012670
The applicant shall stage all construction activity and materials upon their
property.
Planner: Warren Campbell DRB Fee Paid: $250.00
�
�' A �� D � �( � � �] � ment of Community Development
v v 75 South Frontage Road
TOWN OF VA►l=`h� JUN 2 2 1U1Z va�i, co s�ss7
Tel: 970-479-2128
� 3:�Q www.vailgov.com
TOWN OF VAIL Development Review Coordinator �
Application for Design Review
Minor Exterior AI#eration '�
�
General Information: This application is required for all proposals involving minor changes to buildings and site improve- I
ments, such as roofing, painting, window additions, landscaping, fences, retaining walls, etc. Applicable Vail Town '
Code sections can be found at www.vailqov.com under Vail Information—Town Code Online. All projects requiring de-
sign review must receive approval prior to submitting a building permit application. An app►ication for Design Review
cannot be accepted until all required information is received by the Community Development Department; as outlined in
the submittal requirements. The project may also need to be reviewed by the Town Council and/or the Planning and
Environmental Commission. Design review approval expires one year from the date of approval, unless a building per-
mit is issued and construction commences.
� m►D��� cREE�- ����.��c �
I
Fee: 250 or Multi-Family/Commercial
$20 for Single Family/Duplex �� ����
Single Family Duplex Multi-Family /� Commercial
Description of the Request: (�U 11 CE,t�C g l (� '�1� �
r�;�(Y1 IN1U�ll �
Physical Address: i`IS ��� �!� "�w �C�.�1 C0�0(C�L��? �� ��� �—
I
Parcel Number: ��� E (Contact Eagle Co. Assessor at 970-328-8640 for parcel no.)
Property Owner: ( 1 �� lM�.(, �Vl/l � ,
Mailing Address: t�lt�E. i�1t-�` R�ev�u�, 5�;1-e, �o�� aer�v r, (o�orc.�o S�%�b3- I�35
�Phone: /- 303 - 8�C 3--�`IOG
Owner's Signature:
Primary Contact/ Owner Representative: �-c.-t �uc.��
MailingAddress: I�{S�N. ��tac,,� �. (�• � ���C3C �C�.t� . ��o�o�ac�v 8(�S�—
Phone: ���- y��" �'Z��
E-Mail: ,�,ns��M�c;ldlncr ec.l,�vc�;� e C o r� Fax: �ti �� - y��1 - �32 C:! /
�
For Office Use Only:
Cash 1� CC: Visa/MC Last 4 CC# Exp. Date: Auth# Check#
Fee Paid: (j�SO-�� Received From: ���jLE eREE�C, Ult-LAG,�
Meeting Date: DRB No.: ___�Rg�a ����
Planner: Project No: ����a ^ �3 � 9
Zoning: Land Use:
Location of the Proposal: Lot:___�___ Block: Subdivision: m_�(�E LIC�E1/�
/
ii
BBQ Area Pricing for Middle Creek Village
Items Pricing Company
Concrete Pumpin (3 hours) $435 Highline Concrete Pumping LLC
Concrete $50 Highline Concrete Pumping LLC
Landsca in $250 Shem -Skitsteer Time
Framin $100 Shem
Finishin of Concrete $250 Highline Concrete Pumping LLC
http://www.parkn pool.com/picn ic-ta bles/rectang le-park-
Picnic Table $570 furniture.php
Grills (2) $1,146.57 http://www.furnitureleisure.com/home.asp?cid=245
http://www.globalindustrial.com/p/janitorial-
maintenance/garbage-recycling/animal-resistant-
receptacles/bearsaver-be-series-70-gal-animal-resistant-
Bear Safe Trash Can $904 waste-receptacle-green
Coal Dro $300 http://www.pilotrock.com/park_grills/hot_coal bin.htm
Grill Scrubbers $30
http://www.pbp1.com/Property/Product/Grounds/Indoor-
BBQ Area Si n $50 And-Outdoor-Furnishings/Grills-and-Accessories/SN396
http://www.google.com/products/catalog?riz=1 T4ADFA
enUS400US404&q=park+benches+for+sale&um=1&ie=
UTF-
8&tbm=shop&cid=9760796488628882132&sa=X&ei=oE
Benches $130 vWT-6FM4WS9gTCxsnqAw&ved=OCOsBEPICMAU
http://www.petwasteeliminator.com/superior-pet-waste-
Pet Waste Stand $169 eliminator-station/E3
Estimated Total $4,385
Notes
The price includes tax and S/H
for two covered grills
Not includin tax or shi pin .
Not includin tax or shippin .
estimate
idea of si n for area
Pet Areas on the east side of the
property and in front of A
building
extra pet station on the east pet
area
��� �� �
a3�xa3�' ��'s X ay.as''
C�I
D��p �
��
picnic table
� � �
� � x Sq• S '
lR,s�x a�.as'
�6''Xa�'
���� G� � ( �
� �/
;.:
...... .- � �
���• ... /
� . .. ......... �
������ . � .
, � � �,
.:. \`��,
w::` , � ����� MOUNT N BEL �..
m
Y
. � � � � \ �1
i �
; % ,
�,;
F� 6 � /
� Jr���� �w �e [�
i I � 8S . �,�,G
! � � � `�. �
' �• _"- _ RFCRF N ,�y�.
1� .���,.:''' i�i'O� ��� Alr�� ���1 Pl��
� � � �_ ti Q'{
- ` .J
�;,
�� � \
'__- � -
O '
. /, UIL�NQ�
o ��
� � g
� � - �
� � �6
GENERAL REQUIREMENTS
projection room complying with Section 409 of the Interna- 307.4.3 Portable outdoor fireplaces. Portable outdoor
tional Building Code. fireplaces shall be used in accordance with the manufac-
306.2 Cellulose nitrate film storage. Storage of cellulose turer's instructions and shall not be operated within 15 feet
nitrate film shall be in accordance with NFPA 40. (3048 mm) of a structure or combustible material.
Exception:Portable outdoor fireplaces used at one-and
two-family dwellings.
SECTION 307 307.5 Attendance. Open burning,bonfires,recreational fi�s
I OPEN BURNING,RECREATIONAL FIRES and use of portable outdoor fireplaces shall be constantly
AND PORTABLE OUTDOOR FIREPLACES attended until the fire is extinguished.A minimum of one por-
307.1 General.A person shall not kindle or maintain or autho- table fire extinguisher complying with Section 906 with a mini-
rize to be kindled or maintained any open burningunless con- mum 4-A rating or other approved on-site fire-extinguishing
ducted and approved in accordance with this section. equipment, such as dirt, sand, water barrel, garden hose or
water truck,shall be available for immediate utilization.
307.1.1 Prohibited open burning. Open burning that is
offensive or objectionable because of smoke emissions or
when atmospheric conditions or local circumstances make SECTION 308
such fires hazardous shall be prohibited. OPEN FLAMES
307.2 Permit required. A permit shall be obtained from the 308.1 General. Open flame,fire and burning on all premises
8re code ofiScial in accordance with Section 105.6 prior to shall be in accordance with Sections 308.1.1 through 308.4.1
kindling a fire for recognized silvicultural or range or wildlife and with other applicable sections of this code.
management practices, prevention or control of disease or 308.1.1 Where prohibited.A person shall not take or uti-
pests,or a bonfire.Application for such approval shall only be lize an open flame or light in a structure,vessel,boat or other
presented by and permits issued to the ownerof the land upon place where highly flammable, combustible or explosive
which the�re is to be kindled. material is utilized or stored. Lighting appliances shall be
307.2.1 Authorization. Where required by state or local well-secured in a glass globe and wire mesh cage or a simi-
law or regulations, open burning shall only be permitted lar approved device.
with prior approval from the state or local air and water 308.1.2 Throwing or placing sources of ignition.No per-
quality management authority,provided that all conditions son shall throw or place,or cause to be thrown or placed,a
specified in the authorization are followed. lighted match,cigar,cigarette,matches,or other flaming or
307.3 Extinguishment authority. The fire code official is glowing substance or object on any surface or article where
authorized to order the extinguishment by the permit holder, it can cause an unwanted�re.
another person responsible or the fire department of open burn- 308.1.3 Torches for removing paint. Persons utilizing a
ingthat creates or adds to a hazardous or objectionable situa- torch or other flame-producing device for removing paint
tion. from a structure shall provide a minimum of one portable
307.4 Location.The location for open burningshall not be less fire extinguisher complying with Section 906 and with a
than 50 feet (15 240 mm) from any structure, and provisions minimum 4-A rating,two portable fire extinguishers,each
shall be made to prevent the fire from spreading to within 50 with a minimum 2-A rating,or a water hose connected to the
feet(15 240 mm) of any structure. water supply on the premises where such burning is done.
The pe�son doing the burning shall remain on the premises 1
Exceptions: hour after the torch or flame-producing device is utilized.
�
1. Fires in app�oved containers that are not less than 15 �308.1.4 Open-tlame cooking devices. Charcoal burners
feet(4572 mm) from a structure. and other open-flame cooking devices shall not be operated
2. The minimum required distance from a structure shall on combustible balconies or within 10 feet (3048 mm) of
be 25 feet(7620 mm)where the pile size is 3 feet(914 combustible construction.
mm)or less in diameter and 2 feet(610 mm)or less in Exceptions:
height.
1. One-and two-family dwellings.
307.4.1 Bonfires.A bonfire shall not be conducted within
50 feet(15 240 mm) of a structure or combustible material 2• Where buildings, balconies and decks are pro-
unless the fire is contained in a barbecue pit. Conditions tected by an automatic sp�rnkler system.
which could cause a fire to spread within 50 feet (15 240 3. LP-gas cooking devices having LP-gas container
mm) of a structure shall be eliminated prior to ignition. with a water capacity not greater than 2'/Z pounds
307.4.2 Recreational fires. Recreational fires shall not be [nominal 1 pound (0.454 kp� LP-gas capacityj.
conducted within 25 feet(7620 mm) of a structure or com- 308.1.5 Location near combustibles.Open flames such as
bustible material. Conditions which could cause a fire to from candles,lanterns,kerosene heaters and gas-fired heat-
spread within 25 feet(7620 mm)of a structure shall be elim- ers shall not be located on or near decorative material or
inated prior to ignition. similar combustible materials.
I 2009 INTERNATIONAL FIRE CODE° 35