- Jo2 Town of Vail
FIELD
W }jx _ Y
�.
' e
COP
C-
,
a
� /zq /lam.
IM
�Slt-1 Psc>4 U 2S
4�&t't C ior- -•
---{2) - 2-m- t c T4jE1:b.t1--C> uE s
j ev ~ �`
Town of Vail
REVIEWED FOR CODE
COMPLIANCE
Date:- Z -�- - -Z
Bye - --
Code:
Monroe & Newell
Engineers, Inc.
A 70 Benchmark Rd. Suite 204
P.O. Box 15597
Avon, Colorado 81620
i f� —1 .0-- —t-
a J,
Monroe & Newell JOB.
Engineers, Inc. SHEET NO. OF
CALCULATED BY DATE
A CHECKED BY DATE
S R
CAI F
PROCLX— 204 1 jWe Sher) 205 I (Pad6ol)
vt
�v
J
2
3
G. CODE USED IN DESIGN: INTERNATIONAL BUILDING CODE, 2009 EDITION.
TESTING, INSPECTIONS AND OBSERVATIONS:
A. THE STRUCTURAL ENGINEER DOES NOT PROVIDE INSPECTIONS OF CONSTRUCTION.
STRUCTURAL ENGINEER MAY MAKE PERIODIC OBSERVATIONS OF THE
CONSTRUCTION; SUCH OBSERVATIONS SHALL NOT REPLACE REQUIRED
INSPECTIONS BY THE GOVERNING AUTHORITIES OR SERVE AS "SPECIAL
INSPECTIONS" AS MAY BE REQUIRED BY CHAPTER 17 OF THE INTERNATIONAL
BUILDING CODE.
B. THE FOLLOWING WORK SHALL BE INSPECTED BY THE SPECIAL INSPECTOR UNLESS
SPECIFICALLY WAIVED BY THE BUILDING OFFICIAL.
1. SOIL PREPARATION
2
FOUNDATIONS
a. EARTHWORK EXCAVATION, PLACEMENT AND COMPACTION OF FILL
AND IN -PLACE DRY DENSITY OF THE COMPACTED FILL FOR
CONFORMANCE WITH THE APPROVED REPORT.
CONCRETE CONSTRUCTION
a. PERIODIC INSPECTION OF REINFORCING STEEL.
b. PERIODIC VERIFICATION OF USE OF REQUIRED DESIGN MIX.
C. CONTINUOUS INSPECTION AT THE TIME FRESH CONCRETE IS SAMPLED
TO FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND
AIR CONTENT TESTS AND DETERMINE THE TEMPERATURE OF THE
CONCRETE.
d. CONTINUOUS INSPECTION OF CONCRETE AND SHOTCRETE PLACEMENT
FOR PROPER APPLICATION TECHNIQUES.
e. PERIODIC INSPECTION FOR MAINTENANCE OF SPECIFIED CURING
TEMPERATURE AND TECHNIQUES.
A. MAXIMUM SOIL DESIGN PRESSURE ASSUMED IN DESIGN IS 2000 PSF. CONTRACTOR
SHALL RETAIN A LICENSED SOILS ENGINEER TO INSPECT THE FOOTING EXCAVATION
Town of Vail
REVIEWED FOR CODE
COMPLIANCE
PROJECT: HERBST ENTRY DECK
M &N # 8888
DATE: MAY 29, 2012
Date: � �
B s -° - �--
GENERAL NOTES
Y
Code:
1. LIVE LOADS USED IN DESIGN:
A. ENTRY DECK
100 PSF
B. WIND
3 SECOND GUST
90 MPH
FASTEST MILE
85 MPH
EXPOSURE
B
F. LIVE LOADS ARE REDUCED PER CODE IF APPLICABLE.
2
3
G. CODE USED IN DESIGN: INTERNATIONAL BUILDING CODE, 2009 EDITION.
TESTING, INSPECTIONS AND OBSERVATIONS:
A. THE STRUCTURAL ENGINEER DOES NOT PROVIDE INSPECTIONS OF CONSTRUCTION.
STRUCTURAL ENGINEER MAY MAKE PERIODIC OBSERVATIONS OF THE
CONSTRUCTION; SUCH OBSERVATIONS SHALL NOT REPLACE REQUIRED
INSPECTIONS BY THE GOVERNING AUTHORITIES OR SERVE AS "SPECIAL
INSPECTIONS" AS MAY BE REQUIRED BY CHAPTER 17 OF THE INTERNATIONAL
BUILDING CODE.
B. THE FOLLOWING WORK SHALL BE INSPECTED BY THE SPECIAL INSPECTOR UNLESS
SPECIFICALLY WAIVED BY THE BUILDING OFFICIAL.
1. SOIL PREPARATION
2
FOUNDATIONS
a. EARTHWORK EXCAVATION, PLACEMENT AND COMPACTION OF FILL
AND IN -PLACE DRY DENSITY OF THE COMPACTED FILL FOR
CONFORMANCE WITH THE APPROVED REPORT.
CONCRETE CONSTRUCTION
a. PERIODIC INSPECTION OF REINFORCING STEEL.
b. PERIODIC VERIFICATION OF USE OF REQUIRED DESIGN MIX.
C. CONTINUOUS INSPECTION AT THE TIME FRESH CONCRETE IS SAMPLED
TO FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND
AIR CONTENT TESTS AND DETERMINE THE TEMPERATURE OF THE
CONCRETE.
d. CONTINUOUS INSPECTION OF CONCRETE AND SHOTCRETE PLACEMENT
FOR PROPER APPLICATION TECHNIQUES.
e. PERIODIC INSPECTION FOR MAINTENANCE OF SPECIFIED CURING
TEMPERATURE AND TECHNIQUES.
A. MAXIMUM SOIL DESIGN PRESSURE ASSUMED IN DESIGN IS 2000 PSF. CONTRACTOR
SHALL RETAIN A LICENSED SOILS ENGINEER TO INSPECT THE FOOTING EXCAVATION
AND VERIFY IN WRITING THAT THE ACTUAL SOILS CAPACITY IS EQUAL OR GRATER THAN
ASSUMED.
B. ALL FOOTING BEARING ELEVATIONS SHOWN ARE ASSUMED. EXACT BEARING
ELEVATIONS SHALL BE VERIFIED IN THE FIELD WITH ACTUAL CONDITIONS BY
CONTRACTOR WITH APPROVAL OF SOILS ENGINEER AND ALL BOTTOMS OF FOOTINGS
SHALL BE A MINIMUM OF 48" BELOW EXTERIOR GRADE.
C. ALL FOOTINGS ARE TO BE PLACED ON FIRM, UNDISTURBED, NATURAL SOIL OR
PROPERLY COMPACTED BACKFILL, APPROVED BY THE SOILS ENGINEER. BACKFILL
SHALL BE COMPACTED TO 95% (MINIMUM) MODIFIED PROCTOR DENSITY PER ASTM
D1557 UNLESS OTHERWISE RECOMMENDED IN THE SOILS REPORT. IF SOFT SPOTS ARE
ENCOUNTERED REMOVE SOIL AND RECOMPACT WITH APPROVED FILL (RE: SOIL
REPORT FOR DESCRIPTION OF BEARING SOIL).
D. CONTRACTOR SHALL BACKFILL EQUALLY ON EACH SIDE OF PIERS IN 12 INCH MAXIMUM
VERTICAL LIFTS OR AS RECOMMENDED IN THE SOILS REPORT. REFER TO SOILS
REPORT FOR BACKFILL MATERIAL.
E. CENTER ALL FOOTINGS UNDER COLUMNS UNLESS NOTED OTHERWISE ON PLANS.
F. NOTIFY SOILS ENGINEER WHEN EXCAVATION IS COMPLETED SO THAT CONDITIONS MAY
BE INSPECTED PRIOR TO PLACEMENT OF ANY FILL OR CONCRETE.
G. FOR SOIL DRAINAGE REQUIREMENTS REFER TO SOILS REPORT AND CIVIL DRAWINGS.
CONCRETE
A. ALL CAST -IN -PLACE CONCRETE SHALL BE MADE WITH TYPE I PORTLAND CEMENT,
STONE AGGREGATE AND SHALL SATISFY THE FOLLOWING REQUIREMENTS:
R
II
CONCRETE ITEM F'C MIX TYPE MAX W/C RATIO % AIR REQ.
J
FOOTINGS 3000 psi STD - -- - --
FOUNDATION PIERS 3000 psi STD - -- --- CL
B. FOOTINGS AND PIERS SHALL NOT HAVE JOINTS IN A HORIZONTAL PLANE. ® UJ
C. ALL CONCRETE WORK AND REINFORCEMENT DETAILING SHALL BE IN ACCORDANCID Zl\,D
WITH ACI BUILDING CODE 318 LATEST EDITION, UNLESS NOTED OTHERWISE. USE 'jj Q
STANDARD HOOKS FOR DOWELS UNLESS NOTED OTHERWISE. ALL EXPOSED EDGES'OF
CONCRETE WORK SHALL HAVE 3/4 INCH CHAMFER.
(D
� >
REINFORCEMENT o
0
A. ALL REINFORCING SHALL BE HIGH - STRENGTH DEFORMED BARS CONFORMING TO ASTM
A615, GRADE 60 EXCEPT TIES, STIRRUPS AND PLATE ANCHORS WHICH SHALL BE
DEFORMED BARS, ASTM DESIGNATION A615, GRADE 40 OR ASTM A706 GRADE 60.
B. REINFORCEMENT PROTECTION UNLESS NOTED OTHERWISE:
1. CONCRETE POURED AGAINST EARTH 3"
2. CONCRETE POURED IN FORMS (EXPOSED TO WEATHER OR EARTH) 2"
3 COLUMNS AND BEAMS (TIE BARS) 1 -1/2"
C. REINFORCEMENT PLACEMENT AND TOLERANCES SHALL BE IN ACCORDANCE WITH
SECTIONS 7.5, 7.6 AND 7.7 OF ACI 318, LATEST EDITION.
D. NO SPLICES OF REINFORCEMENT SHALL BE MADE EXCEPT AS DETAILED OR
AUTHORIZED BY THE STRUCTURAL ENGINEER.
WOOD
A. ALL FRAMING AND TRUSS LUMBER SHALL BE DRY DOUGLAS FIR, LARCH, GRADED BY
WESTERN WOOD PRODUCTS ASSOCIATION AND CONFORMING TO INTERNATIONAL
BUILDING CODE AS FOLLOWS:
2" THICK - 4" TO 6" WIDE (WALL STUD ONLY) STUD Fb = 700 PSI
2" TO 4" THICK - 6" AND WIDER NO. 2 Fb = 900 PSI
5" THICK - 5" AND WIDER NO. 1 Fb = 1350 PSI
NOTED ALLOWABLE STRESSES ARE MINIMUMS AND FOR NONREPETITVE USES PRIOR
TO ALLOWABLE STRESS INCREASES.
B. WHEN PRESERVATIVE TREATED LUMBER IS REQUIRED BY CODE ALL CONNECTIONS AND
NAILING SHALL BE ADEQUATELY GALVANIZED (DOUBLE DIPPED OR BETTER).
C. TREATED SILL PLATE LUMBER MAY BE HEM -FIR, STRUCTURAL #1 GRADE.
D. FASTEN ALL WOOD MEMBERS WITH COMMON NAILS ACCORDING TO THE IBC SCHEDULE
TABLE 2304 -9.1 UNLESS NOTED OTHERWISE.
GENERAL
A. ENGINEER'S ACCEPTANCE MUST BE SECURED FOR ALL STRUCTURAL SUBSTITUTIONS.
B. PROVIDE ASPHALTIC MASTIC - COATING ON ALL STEEL AND WOOD EXPOSED TO EARTH.
C WATERPROOFING, VAPOR BARRIERS, ETC., SHALL BE AS SHOWN ON THE
ARCHITECTURAL DRAWINGS AND AS INDICATED IN THE SPECIFICATIONS.
D. ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED AGAINST FIELD
CONDITIONS AND ARCHITECTURAL DRAWINGS.
E. CONTRACTOR SHALL VERIFY ALL ASSUMED EXISTING CONDITIONS. IF CONDITIONS
ARE DIFFERENT THAN ASSUMED, NOTIFY ENGINEER.
Town of Vail
REVIEWED FOR CODE
COMPLIANCE
Date: z--'c r
By:
Code: