Loading...
HomeMy WebLinkAboutF12-0029 application.pdf AUTOMATIC FIRE SPRINKLER SYSTEM EQUIPMENT SUBMITTALS FOR ONE WILLOW BRIDGE E. MEADOWS DR. RETAIL 2, 3 AND 4 VAIL, CO. MICROFAST® AND MicrofastHP® QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS TECHNICAL DATA January 22, 2010 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Microfast® and MicrofastHP® Quick Response Upright and Conventional (Old Style) Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes, temperature ratings, and K-Factors to meet design requirements. The special Polyester and Teflon® coatings can be used in decorative applications where colors are desired. In addi- tion, these coatings have been investigated for installation in corrosive atmos- pheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Polyester coat- ings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 NYC Approved: Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 ABS Certified: Certificate 04-HS407984B-PDA VdS Approved: Certificate G4060054, G4060056, G4880046, G4930039, and G4980020 LPC Approved: Ref. No. 096e/03, TE30401, and TE30872 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40131, and 0786-CPD-40171 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to the Approval Chart on page 51d and Design Criteria on page 51e for cULus and FM approval requirements that must be followed. 3. TECHNICAL DATA Specifi cations: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinklers VK315 and VK340 are rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- sure (HP) sprinklers can be identified by locating “250” stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Chart Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Chart *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 06661B, 06766B, 07060, and 12281. Brass UNS-C84400 for all other sprinklers. Deflector: Brass UNS-C23000 or Copper UNS-C19500 for Sprinklers 06661B and 12281. Copper UNS-C19500 for Sprinklers 06665B, 06764B, and 07060. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06719B, 06717B, and 12286): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Form No. F_080488 Viking Technical Data may be found on The Viking Corporation’s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Sprinkler 51a Replaces page 51a-e, dated April 25, 2008. (Updated sprinkler materials. Min. operating pressure for LPCB and CE approval ONLY is 5 psi (0.35 bar). Added alternate frame material for Sprinklers 06661B, 06766B, 07060, and 12281. Removed VdS Approval from Sprinklers 06665B, 06764B, and 14817.) TECHNICAL DATA January 22, 2010 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com MICROFAST® AND MicrofastHP® QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Pip Cap Attachment (for Sprinklers VK300 and VK325): Brass UNS-C36000 For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Polyester = M-/W, Black Polyester = M-/B, and Black Teflon® = N Temperature Suffix (°F/°C): 135°/57° = A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK300 with a 1/2” thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 06661BAB Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the “Sprinkler Accessories” section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000) Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. Sprinkler 51b MICROFAST® AND MicrofastHP® QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS TECHNICAL DATA January 22, 2010 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Sprinkler 51c Figure 1: Standard Sprinkler Wrench 10896W/B TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Bulb Color Ordinary135 °F (57 °C)100 °F (38 °C)Orange Ordinary155 °F (68 °C)100 °F (38 °C)Red Intermediate175 °F (79 °C)150 °F (65 °C)Yellow Intermediate200 °F (93 °C)150 °F (65 °C)Green High286 °F (141 °C)225 °F (107 °C)Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings4: White Polyester, Black Polyester, and Black Teflon® Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 51d. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. TECHNICAL DATA January 22, 2010 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com MICROFAST® AND MicrofastHP® QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS Approval Chart Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers Maximum 175 PSI (12 bar) WWP Base Part Number1 SIN Thread Size Nominal K-Factor Overall Length Listings and Approvals3 (Refer also to Design Criteria on page 51e.) NPTBSPU.S.metric2 InchesmmcULus4 FM7 NYC8 VdSLPCB Upright-Standard Orifice 06661BVK3001/2”15 mm5.680.62-3/1656A2A3A2-------- 07060VK345--15 mm5.680.62-3/1656--A3--A3A3B312 B314 Conventional-Standard Orifice 06766BVK3101/2”15 mm5.680.62-3/1656A3--A3--A3B312 B314 Upright-Large Orifice 06665BVK3503/4”--8.0115.22-5/1659A2A3A2--A3B312 -- 14817VK350--20 mm8.0115.22-5/1659A2A3A2--A3B312 -- 06764BVK3501/2”15 mm8.0115.22-5/1659A2--A2-------- Conventional-Large Orifice 06768BVK3543/4”20 mm8.0115.22-5/1659A2--A3--A3B312 -- Upright-Small Orifice10 06717B11 VK3251/2”15 mm2.840.32-3/1656A2A1A2-------- 06719B11 VK3271/2”15 mm4.260.02-3/1656A2--A2-------- 06931B11 VK327--10 mm4.260.02-3/1656------A3--E113 -- Maximum 250 PSI (17 bar) WWP Upright-Standard Orifice Base Part Number1 SIN Thread Size Nominal K-Factor Overall Length Listings and Approvals3 (Refer also to Design Criteria on page 51e.) NPTBSPU.S.metric2 InchesmmcULus4 FMNYC9 VdSLPCB 12281VK3151/2”15 mm5.680.62-3/1656A2--A2-------- Upright-Small Orifice10 1228611 VK3401/2”15 mm2.840.32-3/1656A2--A2-------- Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) C - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 286 °F (141°C) D - 135 °F (57 °C), 155 °F (68 °C), and 175 °F (79 °C) E - 155 °F (68 °C) Approved Finishes 1 - Brass and Chrome-Enloy® 2 - Brass, Chrome-Enloy®, White Polyester5,6, Black Polyester5,6, and Black Teflon®5 3 - Brass, Chrome-Enloy®, White Polyester5,6, and Black Polyester5,6 Footnotes 1 Base part number is shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. 7 For installation in accordance with the latest applicable FM Loss Prevention Data Sheets and Technical Advisory Bulletins. 8 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. 9 Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vol. 16. 10 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. 11 The sprinkler orifice is bushed. 12 Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 13 Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40131. 14 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. Sprinkler 51d MICROFAST® AND MicrofastHP® QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS TECHNICAL DATA January 22, 2010 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Sprinkler 51e DESIGN CRITERIA (Also refer to the Approval Chart on page 51d) cULus Listing Requirements: Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers, or old style (conventional) sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. For conventional sprinklers, refer to the installation guidelines for old style (conventional) sprinklers. • • FM Approval Requirements: For installation in accordance with the latest applicable FM Loss Prevention Data Sheets (including 2-8N) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Wheatland’s Schedule 40 Sprinkler Pipe is a high quality sprinkler pipe offering you the full range of assurances you require. Schedule 40 Sprinkler Pipe has passed some of the toughest lab tests ever created for sprinkler pipe. Wheatland’s schedule 40 Sprinkler Pipe is made from the highest quality steel in one of the nation’s most modern and most complete pipe manufacturing plants. Our proprietary mill coating offers you a clean, corrosion and heat resistant surface that outlasts and outperforms standard lacquer coatings. Plus, this coating can be quickly and easily painted without special preparation. Or it may be hot-dipped galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifi cation of ASTM A795. Schedule 40 is also available as ASTM A 53 in NPS 1 - 6 and is UL & C-UL Listed and FM Approved. Wheatland’s Schedule 40 Standard Wall Sprinkler Pipe meets or exceeds the following: UL & C-UL Listed• FM Approved• ASTM A795, Type E, Grade A• Sprinkler Pipe Specifi cations NPS Nominal O.DNominal I.DNominal WallNominal Weight UL CRR*Pieces Lift in.mmin.mmin.mmlbs./ft.kg/m 1”1.31533.41.04926.6.1333.381.682.501.0070 1 1/4”1.66042.21.38035.1.1403.562.273.391.0051 1 1/2”1.90048.31.61040.9.1453.682.724.051.0044 2”2.37560.32.06752.5.1543.913.665.451.0030 * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY * The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). Please refer to appropriate documentation for up-to-date listing and approval information. Specifi cations and descriptions are accurate as known at time of publication and are subject to change without notice. Wheatland’s Made in the U.S.A. by Wheatland Tube Company means made to the highest standards for consistant quality. Specifi cations and Approvals 700 South Dock Street, Sharon, PA 16146 Ph 800.257.8182 Fax 724.346.7260 www.wheatland.com Wheatland Tube Company 0309 1.0Mrev02 Effective February 23, 2009 Coated Black Sprinkler Pipe Page 40 D.I. THREADED FITTINGS For fire protection services request submittal GRS 1.3 DUCTILE IRON 90 DEG. ELBOW NOMINALITEMMAX.WEIGHT SIZECODEWORKING EACH (INCH)#P.S.I.ABPIECE 1DB900335001.501.500.62 1 1/4DB900445001.751.750.90 1 1/2DB900555001.941.941.20 2DB900665002.252.251.85 DIMENSIONS DUCTILE IRON STRAIGHT TEE NOMINALITEMMAX.WEIGHT SIZECODEWORKING EACH (INCH)#P.S.I.ABPIECE 1DT3335001.501.500.85 1 1/4DT4445001.751.751.22 1 1/2DT5555001.941.941.55 2DT6665002.252.252.45 DIMENSIONS DUCTILE IRON RED.90 DEG. ELBOW NOMINALITEMMAX.WEIGHT SIZECODEWORKING EACH (INCH)#P.S.I.ABPIECE 1X1/2DB900315001.261.360.44 1X3/4DB900325001.371.450.52 1 1/4X1/2DB900415001.341.530.64 1 1/4X3/4DB900425001.451.620.72 1 1/4X1DB900435001.581.670.75 1 1/2X1DB900535001.651.800.92 1 1/2X1 1/4DB900545001.821.881.08 2X1/2DB900615001.491.881.08 2X3/4DB900625001.601.971.24 2X1DB900635001.732.021.40 2X1 1/4DB900645001.902.101.52 2X1 1/2DB900655002.022.161.65 DIMENSIONS DUCTILE IRON COUPLING NOMINALITEMMAX.DIMENSIONWEIGHT SIZECODEWORKINGEACH (INCH)#P.S.I.APIECE 1DCL0335001.670.40 1 1/4DCL0445001.930.57 1 1/2DCL0555002.150.75 2DCL0665002.531.15 DUCTILE IRON RED. COUPLING NOMINALITEMMAX.DIMENSIONWEIGHT SIZECODEWORKINGEACH (INCH)#P.S.I.APIECE 1X1/2DRC0315001.690.39 1X3/4DRC0325001.690.53 DUCTILE IRON 45 DEG. ELBOW NOMINALITEMMAX.WEIGHT SIZECODEWORKING EACH (INCH)#P.S.I.ABPIECE 1DB450335001.121.120.46 1 1/4DB450445001.291.290.73 1 1/2DB450555001.431.430.92 2DB450665001.681.681.50 DIMENSIONS DUCTILE IRON THREADED FITTINGS ARE UL, ULC LISTED AND FACTORY MUTUAL APPROVED FOR 500 PSI SERVICE. DUCTILE IRON PER ASTM A 536 GRADE 65-45- 12. DIMENSIONS CONFORM TO ANSI B16.3 CLASS 150. THREADS ARE NPT PER ANSI/ASME B1.20.1 NOTICE: DUCTILE IRON FITTINGS HAVE HIGHER TENSILE STRENGTH THEN THAT OF STEEL PIPE. THEREFORE, OVER TIGHTENING CAN CAUSE DAMAGE TO PIPE THREADS WHICH MAY CAUSE LEAKAGE. DUCTILE IRON FITTINGS SHOULD BE TIGHTENED THREE TURNS BEYOND HAND TIGHT, BUT NO MORE THAN FOUR TURNS. A Page 41 DUCTILE IRON REDUCING TEE NOMINALITEMMAX.WEIGHT SIZECODEWORKINGEACH (INCH)#P.S.I.ABCPIECE 1X1X1/2DT3315001.261.261.360.64 1X1X3/4DT3325001.371.371.450.73 1X1/2X1DT3135001.501.361.500.71 1X3/4X1DT3235001.501.451.500.76 1X1X1 1/4DT3345001.671.671.580.98 1X1X1 1/2DT3355001.801.801.651.16 1 1/4X1X1/2DT4315001.341.261.530.82 1 1/4X1X3/4DT4325001.451.371.620.90 1 1/4X1X1DT4335001.581.501.671.00 1 1/4X1X1 1/4DT4345001.751.671.751.08 1 1/4X1X1 1/2DT4355001.881.801.821.42 1 1/4X1 1/4X1/2DT4415001.341.341.530.86 1 1/4X1 1/4X3/4DT4425001.451.451.620.92 1 1/4X1 1/4X1DT4435001.581.581.670.95 1 1/4X1 1/4X1 1/2DT4455001.881.881.821.45 1 1/4X1 1/4X2DT4465002.102.101.901.75 1 1/2X1X1/2DT5315001.411.341.660.95 1 1/2X1X3/4DT5325001.521.371.751.14 1 1/2X1X1DT5335001.651.501.801.17 1 1/2X1X1 1/4DT5345001.821.671.881.34 1 1/2X1X1 1/2DT5355001.941.801.941.45 1 1/2X1 1/4X1/2DT5415001.411.341.661.05 1 1/2X1 1/4X3/4DT5425001.521.451.751.15 1 1/2X1 1/4X1DT5435001.651.581.801.25 1 1/2X1 1/4X2DT5465002.162.102.021.90 1 1/2X1 1/2X1/2DT5515001.411.411.161.15 1 1/2X1 1/2X3/4DT5525001.521.521.751.24 1 1/2X1 1/2X1DT5535001.651.651.801.30 1 1/2X1 1/2X1 1/4DT5545001.821.821.881.48 1 1/2X1 1/2X2DT5565002.162.162.021.98 2X1X2DT6365002.252.022.252.15 2X1 1/4X2DT6465002.252.102.252.30 2X1 1/2X1/2DT6515001.491.411.881.50 2X1 1/2X3/4DT6525001.601.521.971.62 2X1 1/2X1DT6535001.731.652.021.64 2X1 1/2X1 1/4DT6545001.901.822.101.80 2X1 1/2X1 1/2DT6555002.021.942.162.00 2X1 1/2X2DT6565002.252.162.252.35 2X2X1/2DT6615001.491.491.881.60 2X2X3/4DT6625001.601.601.971.68 2X2X1DT6635001.731.732.021.85 2X2X1 1/4DT6645001.901.902.102.04 2X2X1 1/2DT6655002.022.022.162.18 2X2X2 1/2DT5565002.602.602.393.61 2 1/2X2X3/4DT7625001.741.602.322.28 DIMENSIONS DUCTILE IRON CAP NOMINALITEMMAX.DIMENSIONWEIGHT SIZECODEWORKINGEACH (INCH)#P.S.I.APIECE 1DCP0035001.160.32 1 1/4DCP0045001.280.43 1 1/2DCP0055001.330.60 2DCP0065001.450.91 DUCTILE IRON CROSS NOMINALITEMMAX.WEIGHT SIZECODEWORKING EACH (INCH)#P.S.IABPIECE 1DX0335001.501.500.98 1 1/4DX0445001.751.751.50 1 1/2DX0555001.941.941.90 2DX0665002.252.252.95 1 1/4X1DX0435001.581.671.27 1 1/2X1DX0535001.651.801.48 2X1DX0635001.732.022.10 DIMENSIONS DT667 DUCTILE IRON BUSHINGS NOMINALITEM SIZECODE (INCH)# DIMENSIONS 1x1/2DBUSH310.750.251.42OUT 1x3/4DBUSH320.750.251.42OUT 1 1/4x1DBUSH430.800.281.76OUT 1 1/2x1DBUSH530.830.312.00OUT 1 1/2x1 1/4DBUSH540.830.312.00OUT 2x1DBUSH630.880.411.95IN 2x1 1/4DBUSH640.880.342.48OUT 2x1 1/2DBUSH650.880.342.48OUT 0.22 0.17 0.28 0.44 0.30 0.66 0.72 0.61 DIMENSIONS ABC STYLE WT. EACH D.I. THREADED FITTINGS For fire protection services request submittal GRS 1.3 OUTSIDE HEADINSIDE HEAD Main Office/Manufacturing Facility•1375 Sampson Ave. •Corona, CA 92879 •Ph: 909.737.5599 •Fax: 909.737.0330 Customer Service•800.786.5266 www.tolco.com 86 wwwwww..ttoollccoo..ccoomm Revision 5/24/2001 ™ ® a brand of Fig.200 - “Trimline”Adjustable Band Hanger Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil.Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes.Knurled swivel nut design permits hanger adjustment after installation. Features — •(1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion.Captured design keeps adjusting nut from separating with hanger.Hanger is easily installed around pipe. •(21/2" thru 8" Spring tension on nut holds it securely in hanger before installation.Adjusting nut is easily removed. Approvals — Underwriters’Laboratories listed (1/2" thru 8") in the USA (UL)and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8").Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature — 650°F Finish — Mil.Galvanized.For Stainless Steel materi- als, order TOLCO™ Fig.200WON. Order By — Figure number and pipe size Dimensions • Weights Pipe Rod SizeMax.Rec.Approx. SizeInchMetric ABLoad Lbs.Length 1/23/88mm or 10mm31/8 25/8 40011 3/43/88mm or 10mm31/8 21/2 40011 13/88mm or 10mm33/8 25/8 40012 11/4 3/88mm or 10mm33/4 27/8 40013 11/2 3/88mm or 10mm37/8 27/8 40014 23/88mm or 10mm41/2 340015 21/2 3/810mm55/8 41/8 60027 33/810mm57/8 460029 31/2 3/810mm73/8 51/4 60034 43/810mm73/8 5100035 51/212mm91/8 61/4 125066 61/212mm101/8 63/4 125073 81/212mm131/8 83/4 1250136 OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE. •CORONA, CA 92879 •PH: 951.737.5599 •FAX: 951.737.0330 CUSTOMER SERVICE•800.786.5266 www.tolco.com 66 wwwwww..ttoollccoo..ccoomm ™ ® a brand of Revision 9/22/2001 Fig.65 andFig.66 ReversibleC-TypeBeamClamps 3/4" and11/4" ThroatOpenings Size Range — (Fig.65 and Fig.66) 3/8", 1/2" and 5/8" rod Material — Carbon Steel with hardened cup point set screw and jam nut Function — Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig.65) or 11/4" (Fig.66). Features — All steel construction eliminates structural deficiencies associated with casting type beam clamps.May be used on top or bot- tom flange of the beam.(Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position.Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp.Open design permits inspection of thread engagement. Approvals — Underwriters’Laboratories Listed in the USA (UL)and Canada (cUL).Factory Mutual Engineering approved.Conforms to Federal Specification WW-H-171E, Type 23 and Manufacturers Standardization Society SP-69, Type 19.Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD).For additional load, spacing and placement relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Plain Note — Available in Electro-Galvanized and HDG finish. Order By — Figure number, rod size and finish Fig.65 Patent #4,570,885 Dimensions • Weights Rod Size Max.Rec.Approx. A B CDEFLoad Lbs.*Wt./100 3/813/16 3/417/16161028 1/211/2 3/419/1611/4 113055 5/811/2 3/419/1611/4 113055 * Max.loads for clamp with set screw in up or down position. Fig.65 Dimensions • Weights Rod Size Max.Rec.Approx. A B CDEFLoad Lbs.*Wt./100 3/813/16 11/4 17/16161028 1/211/2 11/4 19/1611/4 113055 5/811/2 11/4 19/1611/4 113055 * Max.loads for clamp with set screw in up or down position. Fig.66 Component of State of California OSHPD Approved Seismic Restraints System Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thick Max Thick Box Qty Case Qty 1/4"8024957 DSTR 100 *1/4-20 x 1" TEKS 3 1510 (20 ga.).036"-20 ga 3/16"25 125 1/4"8025957 DST 100 1/4-14 x 1" TEKS 3 446 (20 ga.).036"-20 ga 3/16"25 125 1/4"8026957 DST 150 1/4-14 x 1-1/2" TEKS 3 970 (16 ga.).036"-20 ga 3/16"25 125 1/4"8027957 DST 200 1/4-14 x 2" TEKS 3 446 (20 ga.).036”-20 ga 3/16”25 125 1/4"8030957 TEK 500 12-24 x 1-1/2" TEKS 5 3125 (3/16").187”-3/16”1/2"25 125 3/8"8038957 DSTR 1 *1/4-20 x 1" TEKS 3 1510 (20 ga.)1500 1475 .036"-20 ga 3/16"25 125 3/8"8037957 DSTR 1-1/2 *12-24 x 1-1/2" TEKS 5 1510 (3/16")1500 1475 .060”-16 ga.1/2"25 125 3/8"8039957 DSTR 516 *5/16-18 x 1-1/4" TEKS 3 2200 (20 ga.)1500 1475 .036"-20 ga 1/8"25 125 3/8"8040957 DST 10 1/4-14 x 1" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8077925 DST 10-SS 1/4-14 x 1" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8041957 DST 15 1/4-14 x 1-1/2" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8078925 DST 15-SS 1/4-14 x 1-1/2" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8042957 DST 20 1/4-14 x 2 TEKS" 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8043957 DST 25 1/4-14 x 2-1/2" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8044957 DST 30 1/4-14 x 3" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8045957 DST 516 5/16-18 x 1-1/4" TEKS 3 1500 (3/16")1500 1475 .125"-1/8"1/8"25 125 3/8"8046957 TEK 50 12-24 x 1-1/2" TEKS 5 3125 (3/16")1500 1475 .187”-3/16”1/2"25 125 1/2"8031925 DST 2.0 1/4-14 x 2" TEKS 3 446 (20 ga.) 970 (16 ga.).188"-3/16"1/4"25 125 1/2"8033925 DSTR 1.0 *1/4-20 x 1" TEKS 3 1510 (20 ga.).036"-20 ga 3/16"25 125 1/2"8034925 DSTR 5.16 *5/16-18 x 1-1/4" TEKS 3 2220 (20 ga.).036"-20 ga 1/8"25 125 1/2"8035925 DST 5.16 5/16-18 x 1-1/4" TEKS 3 1500 (3/16").125"-1/8"1/8”25 125 1/2"8036925 TEK 5.0 12-24 x 1-1/2" TEKS 5 3125 (3/16").187"-3/16"1/2"25 125 #14 Black Nut Driver Part # 8113910 #14 SW Red Nut Driver Part # 8114910*Includes retaining nut Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thick Max Thick Box Qty Case Qty 3/8"8137957 SH-DSTR 1 *1/4-20 x 1"3220 (3/16")1500 1475 .035"3/16”25 125 #14 Black Nut Driver Part # 8113910 SAMMY Swivel Head® for Steel 6 For the most up to date information, visit www.sammysuperscrew.com SAMMYS® for Steel Installs VERTICALLY into the bottom of steel structures easily and quickly! VERTICAL MOUNT ST E E L S T E E L S T E E L S T E E L S T E E L SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. pre -drillingno required Product Features • Made with Teks® self-drilling fasteners - no pre-drilling required. • Install into steel range from 22 gauge – 1/2” thicknesses. • Saves time from traditional methods. • Reduces installation cost. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Product Features • Eliminates distortion of threaded rod in sloped roof applications. • Accommodates 3-1/2 x 12 pitch. • Installs into angled Z-Purlin; Allows threaded rod to hang plumb. • Allows 17° deflection from vertical. (Does not comply with ROHS requirements) Installs VERTICALLY and swivels up to 17° in steel structure *Includes retaining nut 7 To find a distributor near you, call 800-BUILDEX Installs VERTICALLY into the bottom of steel structures easily and quickly! HORIZONTAL MOUNT ST E E L S T E E L S T E E L S T E E L S T E E L SIDEWINDERS® for Steel Installs HORIZONTALLY into the side of steel structures easily and quickly! Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thickness Max Thickness Box Qty Case Qty 1/4"8047957 SWD 100 1/4-14 x 1" TEKS 3 1477 (16 ga.).060"-16 ga 3/16"25 125 1/4"8049957 SWDR 100 *1/4-20 x 1" TEKS 3 1900 (20 ga.).036"-20 ga 3/16"25 125 3/8"8050957 SWD 10 1/4-14 x 1" TEKS 3 1477 (16 ga.).060"-16 ga 3/16"25 125 3/8"8080925 SWD 10-SS 1/4-14 x 1" TEKS 3 1477 (16 ga.).060"-16 ga 3/16"25 125 3/8"8051957 SWD 15 1/4-14 x 1-1/2" TEKS 3 1477 (16 ga.).060"-16 ga 3/16”25 125 3/8"8081925 SWD 15-SS 1/4-14 x 1-1/2" TEKS 3 1477 (16 ga.).060"-16 ga 3/16”25 125 3/8"8052957 SWD 20 1/4-14 x 2" TEKS 3 1477 (16 ga.).060"-16 ga 3/16”25 125 3/8"8053957 SWD 516 5/16-18 x 1-1/4" TEKS 3 2480 (20 ga.).036”-20 ga 1/8”25 125 3/8"8055957 SWDR 1 *1/4-20 x 1" TEKS 3 1900 (20 ga.)1500 1475 .036"-20 ga 3/16"25 125 3/8"8054957 SWDR 1-1/2 *12-24 x 1-1/2" TEKS 5 2375 (3/16")1500 1475 .187"-3/16"1/2"25 125 3/8"8056957 SWDR 516 *5/16-18 x 1-1/4" TEKS 3 2480 (20 ga.)1500 1475 .036"-20 ga 1/8"25 125 3/8"8057957 SWT 15 12-24 x 1-1/2" TEKS 5 237 (3/16").187"-3/16"1/2"25 125 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. #14 SW Red Nut Driver Part # 8114910 pre -drillingno required Ultimate Pullout Values (avg. lbs. ultimate) - SAMMYS Fastener Steel Gauge (lbs.) Model Dia.Pt.20 18 16 14 12 3/16 1/4 DST 1/4 #3 446 613 970 1145 1544 3190 DST 516 5/16 #3 457 568 1209 1712 2422 TEK 50 #12 #5 487 699 913 1527 3270 3593 DSTR 1-1/2”#12 #5 3270 3593 DSTR 1”1/4 #3 1510 DSTR 516 5/16 #3 2200 Ultimate Pullout Values (avg. lbs. ultimate) - SIDEWINDERS Fastener Steel Gauge (lbs.) Model Dia.Pt.20 18 16 14 12 3/16 1/4 SWD 1/4 #3 1477 SWDR 1-1/2”#12 #5 2375 SWDR 1”1/4 #3 1900 1900 SWDR 516 5/16 #3 2480 2480 Performance Data - Steel Sheet Steel Gauges Gauge No.26 24 22 20 18 16 14 12 3/16”1/4” Nominal Decimal Equivalent .018 .024 .030 .036 .048 .060 .075 .105 .188 .250 *Includes retaining nut Product Features • Made with Teks® self-drilling fasteners - no pre-drilling required. • Install into steel range from 22 gauge – 1/2” thicknesses. • Saves time from traditional methods. • Reduces installation cost. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Aluminum Curtain Wall Extrusion Ultimate Pullout Values (average lbs. ultimate) Fastener Thickness Model Dia.Pt..114 .092 .365 .132 DST 10 1/4 #3 1265 2750 SWD 10 1/4 #3 1120 1420 Installs VERTICALLY and swivels up to 17° in steel structure OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE. •CORONA, CA 92879 •PH: 951.737.5599 •FAX: 951.737.0330 CUSTOMER SERVICE•800.786.5266 www.tolco.com 70 wwwwww..ttoollccoo..ccoomm ™ ® a brand of Revision 8/15/2005 Size Range — Secures 3/8" thru 7/8" hanger rod Material — Carbon Steel Function — Secures channel to hanger rod for vertical seismic bracing. Approvals — Underwriters Laboratories Listed in the USA(UL) and Canada (cUL).Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish — Electro Galvanized Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number Fig.98 - Rod Stiffener Fig.99 - All ThreadRodCut to Length Size Range — Secures 3/8" thru 7/8" rod in 1" increments Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter, rod length and finish Fig.100 - All ThreadRodFullLengths Size Range — Secures 3/8" thru 7/8" rod in 10’lengths Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter and finish Dimensions • Weights RodMax.Rec.Load Lbs. SizeFor Service Temps 650°F750°F 3/8610540 1/211301010 5/818101610 3/427102420 7/837703360 Dimensions • Weights Max Rec.Load Lbs. RodFor Service TempsApprox. Size650°F750°FWt./100 1/424021512 3/861054029 1/21130101053 5/81810161084 3/427102420123 7/837703360169 149604420222 11/4 80007140360 11/2 1163010370510 Component of State of California OSHPD Approved Seismic Restraints System