HomeMy WebLinkAboutF12-0031TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES SPRINKLER PERMIT Permit #: F12 -0031 Job Address: 2724 BALD MOUNTAIN RD VAIL Status ...: ISSUED Location.....: Applied..: 07/02/2012 Parcel No...: 210103403020 Issued . .: 08/16/2012 Project No Expires . .: $782.63 OWNER WOLFF, LARRY H. & ROSALIND K 07/02/2012 $0.00 DONALD J. $782.63 1000 E 80TH PL 222 BALANCE DUE--- - - - - -> MERRILLVILLE IN 46410 -5644 APPLICANT PHOENIX AUTOMATIC SPRINKLER 07/02/2012 Phone: 303 - 523 -2098 DEPARTMENT 7684 S BRENTWOOD ST LITTLETON McGee Action: CR Provide SSW CO 80128 doors when in o] condition. License: C000003080 CONTRACTOR PHOENIX AUTOMATIC SPRINKLER 07/02/2012 Phone: 303 - 523 -2098 mvaughan Action: AP 7684 S BRENTWOOD ST LITTLETON CO 80128 License: C000003080 Desciption: INSTALL AUTOMATIC FIRE SPRINKLER SYSTEM Valuation: $8,250.00 ************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** FEE SUMMARY ***************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Mechanical --- > $0.00 Restuarant Plan Review - -> $0.00 Total Calculated Fees --- > 5762.63 Plan Check --- > $432.00 DRB Fee------------ - - - - -> $0.00 Additional Fees------ - - - - -> $0.00 Investigation -> $0.00 TOTAL FEES--------- - - - - -> $782.63 Total Permit Fee ---------- > $782.63 Will Call - - - - -> $0.00 Payments ------------- — ---- > $782.63 BALANCE DUE--- - - - - -> $0.00 Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 07/03/2012 McGee Action: CR Provide SSW beneath garage doors when in o] condition. 08/09/2012 mvaughan Action: AP CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 53 (FIRE 2007) Monitored fire sprinkler system required and shall comply with NFPA 13 (2007) and VFES Standards. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY- FQII"OURS IN ADVANCE BY TELEPHONE AT 970 - 479 -2252 FROM 8:00 AM - 5 PM. OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER ,* ,r i t a g > �.-' v � �..z,^4 �, o °z3 a tom« � , �e� - r�. r 3 x :,7:,,,,,,,,, Department offCommunity Developmen 75 South Frontage •ad 1,:, ° , s d;.,',,'% w u:. R 3 v ,. -3F 7 a'c :;\--,' ,�. § Y om' x` R!° .; { ap C' "ail^ Y ,4 ., 5"'4, aR ;.,.,4,7: 1C:,, `* ,; �, ykr �i+� ,'s l � gam. K tr ,� . x; xm FIRE SPRINKLER PERMIT Commercial & Residential Fire Alarm shop drawings are required at the time of application submittal and must include the following information: 1. A Colorado Registered Engineer's stamp or N.I.C.E.T level III (min) stamp 2. Equipment cut sheets of materials 3. Hydraulic calculations 4. A State of Colorado contractor registration number 5. Plans must be submitted by a Registered Fire Protection Contractor Project Street Aess: Office Use:(� Z-7 ZL-{ 13c La w).O i tt,) R6 - Project#: I"IZ,S [Z b0 711 (Number) (Street) (Suite#) i i � Building Permit#: � �2_ —O Og 7 Building/Complex Name: i ( � 2 ( Sprinkler Permit#: `� OO 7 Contractor Information: nn �� . �� 1 � jL�' Lot#: Block# Subdivision: Company: ? i y 1 re,KA I4RC*IAi/�-�Q Company Address: �� 5 atom•1 Sr •' Detailed Description of Work:-I-05i19-I) Av-coM 1 1.0•C City:Lt ffid ) State: Zip: �1 spl2l10��( �u5 fXJ�' • Contact Name: ZOI•3 t ..-1 303 -5�3-zero. (use additional sheet if necessary) Contact Phone: E-Mail (b�• pC1.5t�Gom�s--1 x'1.2.. • • Detailed Location of Work: Z-7 Z� �c ld 1 To, • • • -. actor Registration No.: IX / Does a Monitored Fire Alarm Exist? Yes( ) No( ) Contracto A 'gnature(required) Does a Sprinkler System Exist? Yes( ) No K i Property Information Work Class: Parcel#: 7101 t,31-4 b 3020 New( ) Addition( ) Remodel( ) Repair( ) (For parcel#,contact Eagle County Assessors Office at 970-328-8640 or visit www.eaglecounty.uslpatie) Retro-Fit( ) Other( ) I Tenant Name: Type of Building: Owner Name: Single-Family( ) Duplex( ) Multi-Family( ) Commercial ( ) Restaurant( ) Other( ) 'Complete Valuation for Fire Sprinkler Permit: ; © II E im j 1 Date Received: Fire Sprinkler$: SeZSO I t JUL 0 w 2012 TOWN OF VAIL 01-Feb-10 Town of Vail itA Fire Permit Fee Schedule TOWN OF YAIL Instructions for calculating FIRE ALARM, SPRINKLER or ASBESTOS ABATEMENT permit fees (see applica- ble section below): 1. Determine the valuation (labor&materials) 2. See base Permit Fee (flat fee) 3. Calculate the Plan review fee (multiply the valuation by the applicable percentage listed) Fire Alarm: Permit Fee: 3.75% of the valuation Plan Review Fee: $288.00, due at permit submittal Fire Sprinkler: Permit Fee: 4.25% of the valuation Plan Review Fee: $432.00, due at permit submittal Asbestos Abatement: Permit Fee: $144.00 Plan Review Fee: No review fee F OTHER Fire Permit Fees: F • Permits issued under a Scope of Work letter shall be assessed a fee not less than $144.00 and may be increased at a rate of$72.00 per hour for inspections, revisions, and similar elements. • Re-inspections and plan review for re-submittals shall be billed at$72.00 per hour. • Operational Permits, Special Event Permits, and Construction Permits other than those required for Fire Alarm and Fire Sprinkler systems, issued under provisions of the International Fire Code shall be based on an hourly rate of$72.00 per hour per person for site inspections, plan review and permit processing. 1 gGg €y5y 6F, 5 R WOLF RESIDENCE 2724 BALD MAOUNTAIN ROAD VAIL, COLORADO HYDRAULIC CALCULATIONS AND PRODUCT SUBMITTALS THIS SET OF FI' 3' '. ' ER SH• ' SP CIFI• ■IONS AND HYDRAULIC CALCULATIONS HAVE BEEN REVIE ' ' AND r OUND 0 BE ACC, ' ABLE-N.I.C.E.T.IV#102055 SR ENGINEERING TECH I•N-FI:4 PR• ECTION,N ONAL INSTITUTE FOR CERTIFICATION IN ENGINES' G TECHNICIANS HY N 'O +.i."P ' -S r t DATE PHOENIX AUTOMATIC SPRINKLER 7684 S. BRENTWOOD ST. LITTLETON, CO 80128 720.922.9231 PHONE 1 5,. 7 I t �+ x�x t i I 5g @E@ aad: 1 1 gg� gps yEy� I I- e ) c2 - a ri IT§ e 41 - 2■ 6. § lc E 0 0 _ ' a k111 it - - TsI u \ c ■ ? @ § E2 N N z \ 4 1/M d I- - -- -J � � o m a. $ > N ^ \Q IB B § / o o \ & / o S s\ = 0 ) 0. 0- 5 � 8 4-= � O oo — k k / ■® x = a O N D I. .0 0 o 2 y m 7 ® « § 0 0 k U ¥ a _ § o■ _cr io■∎ k - - « a « t § n. 4) g 2 o 2 u a a § 2� \ ƒ § x2 f C 2 �� E E CC U a a a U- -J 0 ■ig N 1. E c• Z ck N 7 f � �Z § ° » o ) / a o _ - N 0 1 t HYDRAULIC CALCULATIONS t for 1 i Job Information F Project Name:WOLF RESIDENCE I. Contract No.: City: VAIL, CO 3 Project Location: 2724 BALD MAOUNTAIN ROAD Date:12/30/1899 i Contractor Information I Name of Contractor: PHOENIX AUTOMATIC SPRINKLER 3 Address: 7684 S.BRENTWOOD ST. City: LITTLETON, CO 80128 I Phone Number: 720.922.9231 E-mail i! Name of Designer: DLT l I Authority Having Jurisdiction: VAIL FIRE&RESCUE Design I Remote Area Name 1 I i Remote Area Location SECOND FLOOR t Occupancy Classification DWELLING Density(gpm/ft2) 0.1 g Area of Application(ft2) 1024 Coverage per Sprinkler(ft2) 256 Number of Calculated Sprinklers 4 In-Rack Demand(gpm) 0 r, ( Special Heads i Hose Streams(gpm) 0 Total Water Required incl.Hose Streams eq (' Streams)(gpm) 105.3 Pressure at Source(psi) 96.9 Type of System Wet Volume-Entire System (gal) 59.6 gal s Water Supply Information Date 06.22.12 Location NEAR SITE I E t Source W1 I Notes I I r f I z t I File:C:\dwg\Phoenix-wolf residence\wolf res fs-1.dwg Date 6/27/2012 Copyright©2002-2011 Tyco Fire Protection Products Page 2 1' t I l I • n . A 0 • 00 kk _J- §t z� ti / r I CI © § / ■ E ® « 8 ) c U § « CD= .. _ . o in D k { } A 2 ' . § / k $ § ( E £ k 'U 7\ / \ a Z :\ u \ / \ ƒ\ 4 i2 \ \ / ` /t \ \ \ \ \ %—� i � \ \ \ / / \ \ \ , \ \\ 3 } / b \ A. ` / \ W § F) / o § a k k pkp Job:WOLF RESIDENCE • Hydraulic Analysis for : 1 Y Y Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams Fluid Name Water @ 60F(15.6C) Fluid Weight, (Ib/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (Ib•s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters g Supply 1 :W1 Flow(gpm) Pressure(psi) 0 110 1300 85 Hoses Inside Hose Flow(gpm) Outside Hose Flow(gpm) Additional Outside Hose Flow(gpm) Other(custom defined) Hose Flow(gpm) Total Hose Flow(gpm) Sprinklers Ovehead Sprinkler Flow(gpm) 105.3 InRack Sprinkler Flow(gpm) 0 Other(custom defined)Sprinkler Flow(gpm) 0 Total Sprinkler Flow(gpm) 105.3 Other Required Margin of Safety(psi) 0 W1 -Pressure(psi) 96.9 W1 -Flow(gpm) 105.3 Demand w/o System Pump(s) N/A V File:C:\dwg\Phoenix-wolf residence\wolf res fs-1.dwg Date 6/27/2012 Copyright O 2002-2011 Tyco Fire Protection Products Page 4 a, cm to a Cr)• • O 1 ..,..1 O 51 i _ ..., <.,- ID 0) il L g c w- >, Q 3 u N ^ CI $ y LL ej O 0 a� o C Q L1. °3 V O ]___ x N O C a O 3 _d o CO ti v iii it Co I I_--__- _ I j . _r-_..__t 1 -. __,_I 1-t---1-4---1 __ __ r„ - Q Q _ ,-,--,--1 O O 0 O v' o 0 O 0 0 0 0 0 O 0 0 L) M N •— 0 0) CO I- CO LC) CO N %- !sd `eanssaad W 0 Z W a Cl) W N re cs J N CV CO a 0 `o a I Job:WOLF RESIDENCE t Hydraulic Analysis for : 1 1 i Graph Labels Values Label Description Flow (gpm) Pressure(psi) S1 Supply point#1-Static 0 110 S2 Supply point#2-Residual 1300 85 D1 Elevation Pressure 0 11.3 D2 System Demand 105.3 96.9 I Curve Intersections &Safety Margins Curve Name Intersection Safety Margin Pressure(psi) Flow(gpm) Pressure(psi) @ Flow (gpm) Supply 109.7 113.6 12.9 105.3 I I i Open Heads Required Calculated ( Head Ref. Head Type Coverage K-Factor - Density Flow Pressure Density Flow Pressure 1 (ft2) (gpm/Psi') (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (Psi) t 100 5p�inklea 256 4.9 0.1 25.6 27.3 0.1 25.6 27.3 101 Overhead 256 4.9 0.1 25.6 27.3 0.105 27 30.4 Sprinkler t 102 Sprnkledr 256 4.9 0.1 25.6 27.3 0.103 26.3 28.9 E 1 103 Overhead 256 4.9 0.1 25.6 27.3 0.103 26.4 29 Sprinkler ( F 1 i i s i 1 t I i fAA i I 5 f I I i 1 File:C:\dwg\Phoenix-wolf residence\wolf res fs-1.dwg Date 6/27/2012 Copyright©2002-2011 Tyco Fire Protection Products Page 6 1 I Job:WOLF RESIDENCE Hydraulic Calculations/Fluid Delivery Time Analysis Node Data • Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge gpm/psis/z gpm ft2 psi psi ft gpm gpm/ft2 psi gpm 001 Node 29.8 29 NODE -11.7 002 Node 29.8 29 NODE -11.7 003 Node 30.9 29 NODE -11.7 005 Node 35.9 29 NODE -11.7 012 Node 38.5 29 NODE -11.7 018 Node 41.3 29 NODE -11.7 024-A Node 56.3 22 NODE -8.7 024-B Node 72.9 22 NODE -8.7 026 Node 75.9 21 NODE -8.2 036 Node 38.5 29 NODE -11.7 039 Node 30.2 29 NODE -11.7 042 Node 27.4 29 NODE -11.7 049 Node 42.9 19 NODE -7.4 059 Node 42.8 19 NODE -7.4 061 Node 42.8 19 NODE -7.4 065 Node 42.8 19 NODE -7.4 100 Overhead Sprinkler 4.9 25.6 256 27.3 27.3 28 HEAD Open 0 0.1 -11.3 25.6 101 Overhead Sprinkler 4.9 27 256 30.4 27.3 28 HEAD Open 1.4 0.105 -11.3 25.6 102 Overhead Sprinkler 4.9 26.3 256 28.9 27.3 28 HEAD Open 0.7 0.103 -11.3 25.6 103 Overhead Sprinkler 4.9 26.4 256 29 27.3 28 HEAD Open 0.8 0.103 -11.3 25.6 127 Node 30.5 29 NODE -11.7 128 Node 29 29 NODE -11.7 W1 Supply 96.9 -105.3 2 SUPPLY 0 File:C:\dwg\Phoenix-wolf residence\wolf res fs-1.dwg Date 6/27/2012 Copyright©2002-2011 Tyco Fire Protection Products Page 7 . 1 Job:WOLF RESIDENCE Hydraulic Calculations PIPE INFORMATION r Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev(Pe) NOTES T frict(Pf) 's (ft) (gpm/psi1/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 F 100 28 4.9 25.6 1 lx(us.90)=3.11 1 150 27.3 042 29 25.6 1.055 3.11 0.1318 -0.4 k' 4.11 0.5 042 29 0 1 1x(BM.Tee-Br)=5 10.71 150 27.4 039 29 25.6 1.101 2x(BM.90)=10 15 0.107 0 25.71 2.8 039 29 31.8 1 3x(BM.Tee-Run)=3 14.56 150 30.2 036 29 57.4 1.101 3 0.478 0 E 17.56 8.4 036 29 3.3 1.5 2x(BM.Tee-Run)=2 13.36 150 38.5 018 29 60.7 1.598 lx(BM.Tee-Br)=8 18 0.0864 0 lx(BM.90)=8 31.36 2.7 018 29 44.6 1.5 3x(BM.90)=24 24.08 150 41.3 024-A 22 105.3 1.598 2x(BM.Tee-Run)=2 26 0.2396 3 50.08 12 024-A 22 0 1.5 1 0 56.3 4000B DblChk 024-B 22 105.3 0 0 16.6532 0 1 16.7 x 024-B 22 0 1.5 lx(BM.90)=8 2.61 150 72.9 026 21 105.3 1.598 8 0.2396 0.4 i 10.61 2.5 026 21 0 2 4x(us.90)=23.25 119.93 150 75.9 g W1 2 105.3 1.959 23.25 0.0888 8.2 143.19 12.7 ! W1 96.9 I Path No: 2 102 28 4.9 26.3 1 lx(us.90)=3.11 1 150 28.9 128 29 26.3 1.055 3.11 0.1388 -0.4 4.11 0.6 1 128 29 0 1 lx(BM.Tee-Br)=5 1.98 150 29 t 002 29 26.3 1.101 5 0.1127 0 6.98 0.8 002 29 -5.4 1 lx(BM.Tee-Br)=5 10 150 29.8 003 29 20.9 1.101 5 0.0736 0 15 1.1 003 29 27 1 lx(BM.Tee-Run)=1 8.71 150 30.9 t 005 29 47.9 1.101 lx(BM.Tee-Br)=5 6 0.3418 0 g 14.71 5 005 29 0 1.25 3x(BM.Tee-Run)=3 14.7 150 35.9 012 29 47.9 1.394 lx(BM.Tee-Br)=6 9 0.1083 0 23.7 2.6 012 29 -3.3 1.25 6x(BM.Tee-Run)=6 23.21 150 38.5 018 29 44.6 1.394 6 0.0949 0 Y 29.21 2.8 018 41.3 s: 1 File:C:\dwg\Phoenix-wolf residence\wolf res fs-1.dwg Date 6/27/2012 Copyright©2002-2011 Tyco Fire Protection Products Page 8 i I Job:WOLF RESIDENCE Hydraulic Calculations PIPE INFORMATION Path No: 3 103 28 4.9 26.4 1 lx(us.Tee-Br)=7.76 1 150 29 001 29 26.4 1.055 7.76 0.1396 -0.4 8.76 1.2 001 29 5.4 1 lx(BM.Tee-Run)=1 1 150 29.8 039 29 31.8 1.101 1 0.1602 0 2 0.3 039 30.2 Path No: 4 101 28 4.9 27 1 lx(us.90)=3.11 1 150 30.4 127 29 27 1.055 3.11 0.1455 -0.4 4.11 0.6 - 127 29 0 1 lx(BM.Tee-Run)=1 1.98 150 30.5 003 29 27 1.101 1 0.1182 0 2.98 0.4 003 30.9 Path No: 5 002 29 0 1 7.69 150 29.8 001 29 5.4 1.101 0 0.006 0 7.69 0.0 001 29.8 Path No: 6 012 29 0 1.25 lx(BM.Tee-Br)=6 10 150 38.5 065 19 3.3 1.394 6 0.0008 4.3 16 0.0 065 19 -0.9 1.25 lx(BM.90)=6 1.69 150 42.8 061 19 2.4 1.394 lx(BM.Tee-Br)=6 12 0.0004 0 13.69 0 061 19 0 1.25 2x(BM.Tee-Run)=2 11.01 150 42.8 059 19 2.4 1.394 2 0.0004 0 13.01 0 059 19 0.9 1.25 lx(BM.Tee-Run)=1 12 150 42.8 049 19 3.3 1.394 lx(BM.Tee-Br)=6 7 0.0008 0 19 0.0 049 19 0 1.5 2x(BM.Tee-Br)=16 27.58 150 42.9 036 29 3.3 1.598 2x(BM.90)=16 34 0.0004 -4.3 2x(BM.Tee-Run)=2 61.58 0.0 036 38.5 Path No: 7 065 19 0 1.25 8x(BM.Tee-Br)=48 99.43 150 42.8 059 19 0.9 1.394 6x(BM.Tee-Run)=6 78 0.0001 0 4x(BM.90)=24 177.43 0.0 059 42.8 File:C:\dwg\Phoenix-wolf residence\wolf res fs-1.dwg Date 6/27/2012 Copyright©2002-2011 Tyco Fire Protection Products Page 9 1 Job:WOLF RESIDENCE Hydraulic Calculations . PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) . Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict(Pf) (ft) (gpm/psi' ) (gpm) (in) (ft) (ft) (psi) (psi) * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 19.35 ft/s occurs in the following pipe(s): (036-039) t gggg pgk g� gkg gg F g6 File:C:\dwg\Phoenix-wolf residence\wolf res fs-1.dwg Date 6/27/2012 Copyright©2002-2011 Tyco Fire Protection Products Page 10 HYDRAULIC CALCULATIONS for Job Information Project Name:WOLF RESIDENCE Contract No.: City: VAIL, CO Project Location: 2724 BALD MAOUNTAIN ROAD Date:12/30/1899 Contractor Information Name of Contractor: PHOENIX AUTOMATIC SPRINKLER Address: 7684 S.BRENTWOOD ST. City: LITTLETON, CO 80128 Phone Number: 720.922.9231 E-mail: Name of Designer: DLT Authority Having Jurisdiction: VAIL FIRE&RESCUE Design Remote Area Name 2 Remote Area Location BASEMENT Occupancy Classification DWELLING Density(gpm/ft2) 0.1 Area of Application(ft2) 1024 Coverage per Sprinkler(ft2) 256 Number of Calculated Sprinklers 4 In-Rack Demand(gpm) 0 Special Heads Hose Streams(gpm) 0 Total Water Required(incl.Hose Streams)(gpm) 107.3 Pressure at Source(psi) 96.5 Type of System Wet Volume-Entire System (gal) 59.6 gal Water Supply Information Date 06.22.12 Location NEAR SITE Source W1 Notes File:C:\dwg\Phoenix-wolf residence\wolf res fs-1.dwg Date 6/27/2012 Copyright 0 2002-2011 Tyco Fire Protection Products Page 11 ( . ( { & - ( 0_ [ . [ ( ( 00 . - - ( U k § t zff. { [ ( 1 { ( 7 a 1 csi 2 3 S [ © \ f f & § t s ( « 2 (El c o . i ' ( ƒ i CD � 1—! $ % c. x § E w � ° CO N 8 / } \ & - ( = r � E : A:.. f k \ e � D © 0 O } / \ \ ƒ { . \ \ -\ \ < / \ \ \ K k \ \ ! \ 1 / ( 1 ®/1 /2 . z \/ \ \ } ( / { \ 3 § § / § § \ % \ R ( Job:WOLF RESIDENCE Hydraulic Analysis for : 2 Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams Fluid Name Water @ 60F(15.6C) Fluid Weight, (lb/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (Ib•s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters Supply 1 :W1 Flow(gpm) Pressure(psi) 0 110 1300 85 Hoses Inside Hose Flow(gpm) Outside Hose Flow(gpm) Additional Outside Hose Flow(gpm) Other(custom defined) Hose Flow(gpm) Total Hose Flow(gpm) Sprinklers Ovehead Sprinkler Flow(gpm) 107.3 InRack Sprinkler Flow(gpm) 0 Other(custom defined)Sprinkler Flow(gpm) 0 Total Sprinkler Flow(gpm) 107.3 Other Required Margin of Safety(psi) 0 W1 -Pressure(psi) 96.5 W1 -Flow(gpm) 107.3 Demand w/o System Pump(s) N/A File:C:\dwg\Phoenix-wolf residence\wolf res fs-1.dwg Date 6/27/2012 Copyright©2002-2011 Tyco Fire Protection Products Page 13 I . I a � co Q_ • 1 i ▪ A C ANAMMIMMIIIIMIMONei 0 i • .— — M _ O T tt • N f/H r O O 3 t tt —1-1---- 1 -711- 4 H t M . I .t e 0 o • o tt IF vz . a y 0 0 O r E 7 ill 1 :0 0 0 Q C - v▪ I 111 co L i _ H 4 I p LO - o C/3 6 w 0 0 0 0 O 0) 0O OLO OM O LO Cr) N .- 00 � CO pt N .- !sd `a.inssaad w 0 Z W 0 W r N U- p J N 0 t N CO i .0 y 0 0 i Job:WOLF RESIDENCE Hydraulic Analysis for : 2 Graph Labels Values Label Description Flow(gpm) Pressure(psi) S1 Supply point#1-Static 0 110 S2 Supply point#2-Residual 1300 85 - D1 Elevation Pressure 0 2.6 D2 System Demand 107.3 96.5 Curve Intersections &Safety Margins Intersection Safety Margin Curve Name Pressure (psi) Flow(gpm) Pressure (psi) @ Flow (gpm) Supply 109.7 115.3 13.3 107.3 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor - - Density Flow Pressure Density Flow Pressure (ft2) (gpm/psi'h) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) 201 Overhead 256 4.9 0.1 25.6 27.3 0.1 25.6 27.3 Sprinkler 202 Overhead 256 4.9 0.1 25.6 27.3 0.107 27.4 31.2 Sprinkler 203 Overhead 256 4.9 0.1 25.6 27.3 0.105 27 30.3 Sprinkler 204 Overhead 256 4.9 0.1 25.6 27.3 0.107 27.4 31.3 Sprinkler File:C:\dwg\Phoenix-wolf residence\wolf res fs-1.dwg Date 6/27/2012 Copyright©2002-2011 Tyco Fire Protection Products Page 15 i t 1. 1 t Job:WOLF RESIDENCE Hydraulic Calculations/Fluid Delivery Time Analysis 1 1. Node Data Node# Type K-Fact. Discharge Coverage Tot.Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge m z P psi r ft gpm/p1/2 gpm gpm/ft2 psi gpm i 201 Overhead Sprinkler 4.9 25.6 256 27.3 27.3 8 HEAD Open 0 0.1 -2.6 25.6 203 Overhead Sprinkler 4.9 27 256 30.3 27.3 8 HEAD Open 1.4 0.105 -2.6 25.6 202 Overhead Sprinkler 4.9 27.4 256 31.2 27.3 8 HEAD Open 1.8 0.107 -2.6 25.6 204 Overhead Sprinkler 4.9 27.4 256 31.3 27.3 8 HEAD Open 1.8 0.107 -2.6 25.6 075 Node 31.4 a 9 NODE -3 077 Node 31.4 9 NODE -3 S 074 Node 31.5 l 9 NODE -3 078 Node 31.6 1 9 NODE -3 F 012 Node 35.9 29 NODE -11.7 005 Node 36 1 29 NODE -11.7 t 4 059 Node 37 19 NODE -7.4 065 Node 37.3 19 NODE -7.4 036 Node 37.3 29 NODE -11.7 049 Node 38.7 19 NODE -7.4 018 Node 39.6 29 NODE -11.7 E e 024-A Node 55 22 NODE -8.7 024-B Node 72 22 NODE -8.7 026 Node 75 21 NODE -8.2 21 SUPPLY -107.3 96.5 5 f 4 File:C:\dwg\Phoenix-wolf residence\wolf res fs-1.dwg Date 6/27/2012 Copyright©2002-2011 Tyco Fire Protection Products Page 16 f r Job:WOLF RESIDENCE Hydraulic Calculations PIPE INFORMATION Node 1 " Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict(Pf) (ft) (gpm/psis) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 201 8 4.9 25.6 1 lx(BM.Tee-Br)=5 17.4 150 27.3 075 9 25.6 1.101 4x(BM.90)=20 25 0.107 -0.4 42.4 4.5 075 9 -2.1 1.25 lx(BM.Tee-Run)=1 2.71 150 31.4 074 9 23.5 1.394 1 0.0289 0 3.71 0.1 074 9 27.4 1.25 3x(BM.Tee-Br)=18 46.57 150 31.5 065 19 50.9 1.394 3x(BM.90)=18 37 0.121 -4.3 lx(BM.Tee-Run)=1 83.57 10.1 065 19 12.7 1.25 lx(BM.Tee-Br)=6 10 150 37.3 012 29 63.5 1.394 6 0.1826 -4.3 16 2.9 012 29 -11.4 1.25 6x(BM.Tee-Run)=6 23.21 150 35.9 018 29 52.2 1.394 6 0.1268 0 29.21 3.7 018 29 55.2 1.5 3x(BM.90)=24 24.08 150 39.6 024-A 22 107.3 1.598 2x(BM.Tee-Run)=2 26 0.2481 3 50.08 12.4 024-A 22 0 1.5 1 0 55 4000B DblChk 024-B 22 107.3 0 0 16.9468 0 1 16.9 024-B 22 0 1.5 lx(BM.90)=8 2.61 150 72 026 21 107.3 1.598 8 0.2481 0.4 10.61 2.6 026 21 0 2 4x(us.90)=23.25 119.93 150 75 W1 2 107.3 1.959 23.25 0.092 8.2 143.19 13.2 W1 96.5 Path No: 2 203 8 4.9 27 1 lx(BM.Tee-Run)=1 7.19 150 30.3 077 9 27 1.101 lx(BM.90)=5 6 0.1179 -0.4 13.19 1.6 077 9 2.1 1.25 lx(BM.Tee-Run)=1 2.71 150 31.4 078 9 29.1 1.394 1 0.043 0 3.71 0.2 078 9 27.4 1.25 4x(BM.Tee-Br)=24 33.42 150 31.6 059 19 56.5 1.394 3x(BM.Tee-Run)=3 33 0.1469 -4.3 lx(BM.90)=6 66.42 9.8 059 19 -12.7 1.25 lx(BM.Tee-Run)=1 12 150 37 049 19 43.8 1.394 lx(BM.Tee-Br)=6 7 0.0918 0 19 1.7 049 19 0 1.5 2x(BM.Tee-Br)=16 27.58 150 38.7 036 29 43.8 1.598 2x(BM.90)=16 34 0.0472 -4.3 2x(BM.Tee-Run)=2 61.58 2.9 036 29 11.4 1.5 2x(BM.Tee-Run)=2 13.36 150 37.3 018 29 55.2 1.598 lx(BM.Tee-Br)=8 18 0.0723 0 lx(BM.90)=8 31.36 2.3 018 39.6 File:C:\dwg\Phoenix-wolf residence\wolf res fs-1.dwg Date 6/27/2012 Copyright©2002-2011 Tyco Fire Protection Products Page 17 a Job:WOLF RESIDENCE Hydraulic Calculations ( t PIPE INFORMATION f Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) I Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES r T frict(Pf) (ft) (gpm/Psi' ) (gpm) (in) (ft) (ft) (Psi) (Psi) Path No: 3 t I 202 8 4.9 27.4 1 lx(BM.Tee-Br)=5 1 150 31.2 3 074 9 27.4 1.101 5 0.1212 -0.4 =' 6 0.7 074 31.5 I Path No: 4 i 204 8 4.9 27.4 1 lx(BM.Tee-Br)=5 1 150 31.3 078 9 27.4 1.101 5 0.1214 -0.4 6 0.7 078 31.6 Path No: 5 075 9 0 1.25 lx(BM.Tee-Br)=6 14.02 150 31.4 077 9 2.1 1.394 6 0.0003 0 20.02 0 077 31.4 Path No: 6 012 29 0 1.25 3x(BM.Tee-Run)=3 14.7 150 35.9 005 29 11.4 1.394 lx(BM.Tee-Br)=6 9 0.0075 0 23.7 0.2 005 29 0 1 6x(BM.Tee-Run)=6 41.96 150 36 036 29 11.4 1.101 lx(BM.Tee-Br)=5 11 0.0238 0 52.96 1.3 036 37.3 Path No: 7 059 19 0 1.25 2x(BM.Tee-Br)=12 12.7 150 37 , 065 19 12.7 1.394 lx(BM.Tee-Run)=1 19 0.0092 0 lx(BM.90)=6 31.7 0.3 065 37.3 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 17.17 ft/s occurs in the following pipe(s): (024-A-018), (026-024-B) File:C:\dwg\Phoenix-wolf residence\wolf res fs-1.dwg Date 6/27/2012 Copyright©2002-2011 Tyco Fire Protection Products Page 18 Job:WOLF RESIDENCE Device Graphs Pressure vs. Flow Function Design Area: 2; Supply Ref.:W1; Supply Name:W1 125 120 lls: 110 los loo' 95" 90 85 80" 75; 70 3 65 60: ` 55: a 507 45 40 35 30 25' 20 15 10" 5" . . . ... ° °o °o °o °o °o °o °o °o °0 0 N M a 71 .o n m rn o Flow,gpm Pressure Loss Function Design Area: 2; BFP Ref.: 186(4000B DblChk, Size = 1.5) 19.9 18.9: I16.9 psi @107.3gpm 17.9' --- - 16.9 15.9 14.9' s 13.9 y� 12.9 y 11.9" L 10.9- 7 9.9 8.9 a. 7.9 6.9 5.9 4.9 3.9- 2.9 1.9" 0.9 Row,gpm File:C:\dwg\Phoenix-wolf residence\wolf res fs-1.dwg Date 6/27/2012 Copyright©2002-2011 Tyco Fire Protection Products Page 19 r . I WATER FLOW TEST REPORT PROJECT NAME: WOLF RES JOB# I HYDRANT# &LOCATION: 2724 BALD MOUNTAIN RD DATE: 06.22.2012 f S TEST BY: RON KELLY Day or Week: TIME OF DAY: MIN.OF FLOW: WATER SUPPLIED BY: EAGLE RIVER WATER I PURPOSE OF TEST: FIRE FLOW DATA FLOW HYDRANT(S) Al A2 A3 SIZE OPENING: 2.5 0 COEFFICIENT: 0.9 0 PITOT READING: 60 0 GPM: 1300 0 0 TOTAL FLOW DURING TEST: 1300 GPM F STATIC READING: 120 PSI RESIDUAL: 95 PSI RESULTS: AT 20 PSI RESIDUAL 2748 GPM AT 0 PSI 3032 GPM a ESTIMATED CONSUMPTION: 1300 GAL. REMARKS: : E l 150 I 140 130 1 f 120 mIIIMmmomamimmss1111mmIMMMEIMIMm�M 110 msllimm�C RE; �� i o r r�r ■r iimn r��� �ri���� s 100 ■ NIIM■■�Mi11, f 0 co 0 =IIIIIIIIIIIIII1iIi!UIIIHIIIIIIIIIIIII�a 0 d 0 IIIIIIIIIIIIIIIIIOIIIii !iI 40 30 50 20 : : 2748 10 ,",,,,,,,,,,,,,,,,,,,,,,,,,,• 0 3032 0 500 1000 1500 2000 2500 3000 3500 4000 Flow,gpm j F k _ Calculation for size of expansion tank NFPA 13,13R,&13D Minimum _Insert data into yellow boxes only Tank Type of antifreeze used Size Propylene Glycol 8.4 gallons Glycerine! 9.1 i gallons A.7.5.3.2 One formula for sizing the chamber is as follows.Other methods also exist. i a1/. S,,r/&—1 1 where: Ixrr ) 11 A L =change in antifreeze solution volume(gal)due to thermal expansion 2.0413386 2.198198 12 S v=volume(gal)of antifreeze system,not including the expansion chamber 61 13 D D. =density(gm/ml)of antifreeze solution at lowest expected temperature 1.05' 1.15 14 DH=density(gm/ml)of antifreeze solution at highest expected temperature 1.016` 1.11 5 15 This method is based on the following information: !U 7 1= �� Adjusted where: Given Converted 19 VEc=minimum required volume(gal)of expansion chamber 3 20 V 0=air volume(gal)in expansion chamber at precharge(before installation) 1 ° 21 V,=air volume(gal)in expansion chamber at normal static pressure V 2=air volume(gal)in expansion chamber at post-expansion pressure 22 (antifreeze at high temperature) 3 P 0=absolute precharge pressure(psia)on expansion chamber before 23 installation 110 4 125 ° 24 P 1=absolute static pressure(psi)on water(supply)side of backflow preventer I 110 4 125 ° 25 P 2=absolute maximum allowable working pressure(psi)for antifreeze system 150 5 165 ° 26 T°=temperature(°R)of air in expansion chamber at precharge 68° 528 70 T,=temperature(°R)of air in expansion chamber when antifreeze system piping 27 is at lowest expected temperature 68 6 528 10 T 2=temperature(SR)of air in expansion chamber when antifreeze system piping 28 is at highest expected temperature 68° 528 10 This equation is one formulation of the ideal gas law from basic chemistry.The amount of air in the expansion chamber will not change over time.The pressure,temperature,and volume of the air at different times will be related in accordance with this formula. Yz=1%�—M. The antifreeze in the system is essentially incompressible,so the air volume in the expansion chamber will decrease by an amount equal to the expansion of the antifreeze. It is assumed that there is no trapped air in the system piping,so the only air in the system is in the expansion chamber.This is a conservative assumption,since more air is better.In reality,there will be at least some trapped air.However,only the air in the expansion chamber can be relied upon to be available when needed. VEr.= At precharge,the chamber will be completely full of air. = � 10 (P2•7;—P•�r) NFPA 13(02) Density is based on-10°F for 50%propylene glycol and is an estimate of the lowest expected temperature of the mixture in the entire system for a ranch style house.A higher temperature might be expected for a tri-level home.Use density for glycerine under the same conditions 2 Density is based on 130°F for 48%propylene glycol and is an estimate of the highest expected temperature of the mixture in the entire system for a ranch style house.A lower temperature might be expected for a tri-level home.Use density for glycerine under the same conditions 3 It is believed that values for V cancel since the total volume within the chamber does not change 4 The pre-charge pressure will be the same as static pressure at the street or pump chum pressure 5 The maximum allowable working pressure is the same as the maximum listed pressure for the sprinkler heads ° The temperature chosen is based on expansion tanks installed in heated basements Revised 12/06/05 Density values come from Fig 7.5.2.5(a-c)Pg 33-34 ° Left column=glycol;right column=glycerine 60%(-10 to 130) ° Add 15 to all pressure values to include atmospheric pressure 10 Add 459 to F to change to R i • f i f . I CFire Suppression & Building Products ft - k rapid response® Technical Services 800-381-9312 I+1-401-781-8220 HOME FIRE SPRINKLER SYSTEM www.tyco-fire.com I Series LFII Residential Sprinklers Flat-Plate Concealed Pendent t 4.9 K-Factor General The Series LFII Residential Flat-Plate Concealed Pendent Sprinkler has a 4.9 Description (60,5)K-factor that provides the required residential flow rates at reduced pres- is The TYCO RAPID RESPONSE Series sures,enabling smaller pipe sizes and LFII Residential Flat-Plate Concealed water supply requirements. , Pendent Sprinklers(TY2524)are decora- This sprinkler has been designed with tive,fast response,fusible solder sprin- heat sensitivity and water distribution klers designed for use in residential oc- characteristics proven to help in the con- _ cupancies such as homes,apartments, trol of residential fires and to improve ; a dormitories,and hotels. the chance for occupants to escape or `° ; The Cover Plate/Retainer Assembly con- be evacuated. , ceals the sprinkler operating ••> te p p g com o-p The Series LFII Residential Flat-Plate e, I nents above the ceiling.The flat profile Concealed Pendent Sprinklers are j of the Cover Plate provides the optimum shipped with a Disposable Protective i` aesthetically appealing sprinkler design. Cap.The Protective Cap protects the Additionally,the concealed design of the sprinkler during ceiling installation or Series LFII Residential Flat-Plate Con- finish.After ceiling installation is corn- Technical cealed Pendent Sprinklers provides 1/2 plete, the Protective Cap is removed inch(12,8 mm)vertical adjustment.This and the Cover Plate/Retainer Assem- Data adjustment provides a measure of flex- bly is installed. Removing the Protec- r ibility when cutting fixed pipe drops. tive Cap is required for proper sprinkler Approvals t The Series LFII Residential Flat-Plate performance. UL and C-UL Listed Concealed Pendent Sprinklers are in- NSF-61 Certified tended for use in the following systems: NOTICE I The Series LFII Residential Flat-Plate • per NFPA 13D, wet pipe residential The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers are only sprinkler systems for one- and two- Concealed Pendent Sprinklers(TY2524) listed with the Series LFII Concealed family dwellings and mobile homes; described herein must be installed and Cover Plates having a factory-applied •per NFPA 13R, wet pipe residential maintained in compliance with this doc- finish. sprinkler ument and with the applicable standards sprinkler systems for residential oc- cup s up to and including four of the National Fire Protection Associa- Maximum Working Pressure Lion,in addition to the standards of any 175 psi(12,1 bar) stories in height;and authorities having jurisdiction. Failure Discharge Coefficient• per NFPA 13,wet pipe sprinkler sys- to do so may impair the performance K=4.9 GPM/psi112(70,6 LPM/bar"2) terns for the residential portions of of these devices. any occupancy. Owners are responsible for maintaining Temperature Rating their fire protection system and devices Sprinkler: 160°F(71°C) in proper operating condition. The in- over Plate: 139°F(59°C) IMPORTANT stalling contractor or sprinkler manu- Vertical Adjustment ` Always refer to Technical Data facturer should be contacted with any 1/2 inch(12,7 mm) Sheet TFP700 for the "INSTALLER questions. WARNING" that provides cautions Finishes s with respect to handling and instal- Refer to the Ordering Procedure p g Model/Sprinkler g lation of sprinkler systems and com- section. • ponents.Improper handling and in- Identification Physical Characteristics i stallation can permanently damage •Cover Plate/Retainer Assembl a sprinkler system or its components Number (SIN) Cover Plate Co Copper and cause the sprinkler to fail to PP operate in a fire situation or cause it TY2524 Ejection Spring . . .. Stainless Steel 1, to operate prematurely. Retainer Brass Page 1 of 6 OCTOBER 2010 TFP443 K F TFP443 ' Page 2 of 6 Horizontal Ceiling Sloped Ceiling Sloped Ceiling Minimum Flowroland Minimum Flowroland Minimum Flow°land Residual Pressure Residual Pressure Residual Pressure Maximum Maximum (Maximum 2-inch rise (Greater than 2-inch rise (Greater than 4-inch rise Coverage Spacing for 12-inch run) up to maximum 4-inch up to maximum 8-inch Area ou rise for 12-inch run) rise for 12-inch run) 160°F(71°C) 160°F(71°C) 160°F(71°C) Sprinkler Sprinkler Sprinkler 12'x 12' 12' 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) 17 GPM(64,3 LPM) (3,7 m x 3,7 m) (3,7 m) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 12.0 psi(0,83 bar) 14'x 14' 14' 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) 17 GPM(64,3 LPM) (4,3 m x 4,3 m) (4,3 m) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 12.0 psi(0,83 bar) 16'x 16' 16' 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) 17 GPM(64,3 LPM) (4,9 m x 4,9 m) (4,9 m) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 12.0 psi(0,83 bar) 18'x 18' 18' 17 GPM(64,3 LPM) 22 GPM(83,3 LPM) 22 GPM(83,3 LPM) (5,5 m x 5,5 m) (5,5 m) 12.0 psi(0,83 bar) 20.2 psi(1,39 bar) 20.2 psi(1,39 bar) 20'x 20' 20' 20 GPM(75,7 LPM) 24 GPM(90,8 LPM) 24 GPM(90,8 LPM) (6,1 m x 6,1 m) (6,1 m) 16.7 psi(1,15 bar) 24.0 psi(1,65 bar) 24.0 psi(1,65 bar) (a)For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which Hydraulic Design section under the Design Criteria are stated. (b)The Minimum Flow requirement is based on minimum flow in GPM(LPM)from each sprinkler.The associated residual pressures are calculated using the nominal K-factor.Refer to"Hydraulic Design"in the Design Criteria section for details. TABLE A SERIES LFII RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SPRINKLER(TY2524) NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA WET PIPE SYSTEMS •Sprinkler/Support Cup Assembly: For systems designed to NFPA 13,the Body Brass Design number of design sprinklers is to be Cap Bronze C the four most hydraulically demanding Saddle Brass r�ter�a sprinklers.The minimum required dis- Sealing Assembly The TYCO RAPID RESPONSE charge greater of sprinklers Nickel w/Beryllium flon' LFII Residential FFlat-Plat Concealed is o e the of the following: Soldered Link Halves Nickel Pendent Sprinklers (TY2524) are UL •flow rates given in Table A for NFPA Lever Bronze and C-UL Listed for installation in ac- 13D and 13R as a function of tem- Compression Screw Brass cordance with the following criteria. perature rating and the maximum al- Deflector Bronze towable coverage area Guide Pin Housing Bronze NOTICE Guide Pins Bronze •minimum discharge of 0.1 GPM/ Support Cup Steel When conditions exist that are outside sq. ft. over the "design area" com- the scope of the provided criteria,re- prised of the four most hydraulically fer to the Residential Sprinkler Design demanding sprinklers for actual cov- Oeration Guide TFP490 for the manufacturer's erage areas protected by the four p recommendations that may be accept- sprinklers When exposed to heat from a fire,the able to the Authority Having Jurisdiction. Cover Plate,which is normally soldered Obstruction To Water Distribution The Series LFII Residential Flat-Plate to the Retainer at three points,falls away Concealed Pendent Sprinklers must Locate sprinklers in accordance with the to expose the Sprinkler/Support Cup As- not be used in applications where the obstruction rules of NFPA for residential sembly.At this point,the Deflector,sup- air pressure above the ceiling is greater sprinklers as well as obstruction criteria ported by the Guide Pins,drops down than that below. Down drafts through described within TYCO technical data to its operated position. the Support Cup can delay sprinkler op- sheet TFP490. The Solder Link Element of the Sprinkler/ eration in a fire situation. Operational Sensitivity Support Cup Assembly is comprised of Install sprinklers relative to the ceiling two link halves that are soldered togeth- System Type mounting surface as shown in Figure 3. er with a thin layer of solder.When the Only wet pipe systems may be utilized. rated temperature is reached,the sol- Sprinkler Spacing Hydraulic Design The minimums spacing between s rin- der melts and the two link halves sepa- Table A provides the minimum required , g p rate,allowing the sprinkler to activate sprinkler flow rate for systems designed klers is 8 feet(2,4 m). and flow water. to NFPA 13D or NFPA 13R as a function The maximum spacing between sprin- of temperature rating and the maximum klers cannot exceed the length of the allowable coverage areas.The sprinkler coverage area(Table A)being hydrau- flow rate is the minimum required dis- lically calculated;for example,a maxi- charge from each of the total number of mum of 12 feet for a 12 ft.x 12 ft.coy- ' 1 Registered trademark of Dupont "design sprinklers"as specified in NFPA erage area or 20 feet for a 20 ft.x 20 ft. 13D or NFPA 13R. coverage area. At I TFP443 Page 3 of 6 E i BODY /` SEALING 1 (1/2"NPT) / ASSEMBLY . CAP �f���,,i/�lL SPRINKLER j ���r�I '�� /�,'��_j WRENCHING SADDLE i�,a ",•∎,.� _A I AREA SUPPORT 11111111 ! CO PRESSION ROLL FORMED THREADS ) 1 1I LEVER WRENCH 1 ! RECESS GUIDE II I PIN I it■,:■.• SOLDER LINK l\�\ ELEMENT � GUIDE PIN HOUSING I W -e---------m- L (OPERATED PUSH WRENCH I- DEFLECTOR I E r-- 71 I POSITION) IN TO ENSURE SPRINKLER/SUPPORT CUP I ENGAGEMENT ASSEMBLY WITH SPRINKLER WRENCHING AREA I THREAD INTO RETAINER SUPPORT CUP UNTIL MOUNTING )j WITH I DIMPLES THREAD FIGURE2 SURFACE IS \ 0 O I, W-TYPE 18 FLUSH WITH ) EJECTION SPRINKLER WRENCH CEILING SPRING -I L SOLDER COVER PLATE/RETAINER COVER TAB ASSEMBLY PLATE FIGURE 1 FLAT-PLATE CONCEALED PENDENT SPRINKLER(TY2524) ASSEMBLY 2-1/2"DIA. SPRINKLER- I— (63,5 mm) 1/2"(12,7 mm) FACE OF SUPPORT CUP 1/2" THREADED SPRINKLER ASSEMBLY NPT ADJUSTMENT FITTING OPERATED � 'L r SPRINKLER J.COVER coin-11 _1-7/,6 mm' PLATE .�� (47,6 mm ��_�_ _ I 9JI 1 r 1/8"GAP ±3,2 mm) RETAINER 1A.,, -- �_ (3,2 mm) _ ( ■ mot.:._._._._._.... —r I I — COVER- SPRINKLER- MOUNTING 7/8"(22,2 mm) RETAINER SUPPORT CUP 1-1/8"(28,6 mm) 3/16" SURFACE _ �,���.� ASSEMBLY ASSEMBLY (4,8 mm) t "' --"' 3-3/16"DIA. DISPOSABLE DEFLECTOR IN (81,0 mm) TIP PROTECTIVE CAP OPERATED POSITION FIGURE 3 PROTECTIVE CAP AND ACTIVATED DEFLECTOR INSTALLATION DIMENSIONS TFP443 Page 4 of 6 Installation 6. Screw on the Cover Plate/Retainer Replace sprinklers that: Assembly until its flange contacts •were damaged by dropping,striking, The TYCO RAPID RESPONSE Series the ceiling. wrench twisting,wrench slippage,or LFII Residential Flat-Plate Concealed Do not continue to screw on the the like. Pendent Sprinklers must be installed Cover Plate/Retainer Assembly such .,sere modified or over-heated. in accordance with the following that it lifts a ceiling panel out of its instructions. normal position. •are leaking or exhibiting visible signs If the Cover Plate/Retainer Assembly of corrosion. NOTICE cannot be engaged with the Mounting Responsibility lies with owners for the Damage to the Solder Link Element dur- Cup or the Cover Plate/Retainer As- inspection,testing,and maintenance of ing installation can be avoided by han- sembly cannot be engaged sufficiently their fire protection system and devices ding the sprinkler by the Support Cup to contact the ceiling,the Sprinkler in compliance with this document,as only;that is,do not apply pressure to the Fitting must be repositioned. well as with the applicable standards of Solder Link Element(Figure 1). the National Fire Protection Association Obtain a leak-tight 1/2 inch NPT sprinkler Care and (for example,NFPA 25),in addition to joint by applying a minimum-to-maxi- the standards of any other authorities mum torque of 7 to 14 ft.-Ibs.(9,5 to 19,0 Maintenance having jurisdiction.Contact the install- Nm).Higher levels of torque can distort ing contractor or sprinkler manufacturer the sprinkler inlet with consequent leak- The TYCO RAPID RESPONSE Series regarding any questions. age or impairment of the sprinkler. LFII Residential Flat-Plate Concealed Automatic sprinkler systems are rec- Pendent not attempt to compensate for in- Pendent Sprinkler(TY2524) must be o ommended to be inspected, tested, sufficient adjust to c in the Cover Plate/ maintained and serviced in accordance and maintained by a qualified Inspec- Retainer Assembly by under-or over- with the following instructions. tion Service in accordance with local tightening the sprinkler.Re-adjust the requirements and/or national codes. position of the sprinkler fitting to suit. NOTICE 1. Install pendent sprinklers in the Before closing a fire protection system pendent position, with the centre main control valve for maintenance work con- line pendent of the sprinkler with perpendicular center- on the fire protection system that it con- li the the surface. trols,obtain permission to shut down the affected fire protection system from the 2. Remove the Protective Cap. proper authorities and notify all person- nel With pipe-thread sealant applied nel who may be affected by this action. to the pipe threads, and using the When properly installed,there is a nomi- W-Type 18 Wrench shown in Figure nal 1/8 inch(3,2 mm)air gap between 2, install and tighten the Sprinkler/ the lip of the Cover Plate and the ceil- Support Cup Assembly into the fit- ing,as shown in Figure 3.This air gap ting. The W-Type 18 Wrench ac- is necessary for proper operation of the cepts a 1/2 inch ratchet drive. sprinkler by allowing heat flow from a 4. Replace the Protective Cap by fire to pass below and above the Cover pushing it upwards until it bottoms Plate to help assure appropriate release out against the Support Cup. The of the Cover Plate in a fire situation.If the Protective Cap helps prevent dam- ceiling needs repainting after sprinkler installation,exercise care to ensure that age to the Deflector and Guide Pins the new paint does NOT seal off any of ins during ceiling installation and/ the air gap.Failure to do so may impair or during application of the finish coating of the ceiling. sprinkler operation. Absence of a Cover Plate can delay the NOTICE sprinkler operation in a fire situation. As long as the protective Cap re- Do not pull the Cover Plate relative to mains in place, the system is con- the Enclosure.Separation may result. sidered"Out Of Service" Exercise care to avoid damage to sprin- 5. After the ceiling has been com- klers before,during,and after installa- pleted with the 2-1/2 inch (63 mm) tion. Never paint,plate,coat,or other- diameter clearance hole and in wise alter automatic sprinklers after they preparation for installing the Cover leave the factory. Plate/Retainer Assembly, remove Never repaint factory-painted Cover and discard the Protective Cap, Plates.When necessary,replace cover and verify that the Deflector moves plates with factory-painted units. Non- up and down freely. factory applied paint can adversely de- If the Sprinkler has been damaged lay or prevent sprinkler operation in the and the Deflector does not move up event of a fire. and down freely, replace the entire Sprinkler assembly.Do not attempt to modify or repair a damaged sprinkler. 1 TFP443 Page5of6 g 1 S E Limited Ordering f Warranty Procedure Products manufactured by Tyco Fire Contact your local distributor for avail- s Suppression & Building Products ability.When placing an order,indicate t (TFSBP)are warranted solely to the orig- the full product description and Part inal Buyer for ten(10)years against de- Number(P/N). fects in material and workmanship when paid for and properly installed and main- Sprinkler/Support Cup Assembly tamed under normal use and service. Specify: Series LFII Residential Flat- t This warranty will expire ten(10)years Plate Concealed Pendent Sprinkler from date of shipment by TFSBP. No (TY2524), K=4.9,without over Plate/ warranty is given for products or com- Retainer Assembly,P/N 51-114-1-160. ponents manufactured by companies Cover Plate/Retainer Assembly ,' not affiliated by ownership with TFSBP Specify:Cover Plate/Retainer Assem- or for products and components which bly with finish (below) for the Series have been subject to misuse,improper LFII Residential Flat-Plate Concealed installation,corrosion,or which have not Pendent Sprinkler(TY2524),K=4.9,P/N t been installed,maintained,modified or (below): repaired in accordance with applicable . Standards of the National Fire Protection Chrome P/N 56-201-9-135 Association,and/or the standards of any Custom P/N 56-201-X-135 ' other Authorities Having Jurisdiction. Off White P/N 56-201-0-135 Materials found by TFSBP to be defer- Pure White* tive shall be either repaired or replaced, (RAL 9010) P/N 56-201-3-135 at TFSBP's sole option.TFSBP neither assumes,nor authorizes any person to Signal White" assume for it, any other obligation in (RAL 9003) P/N 56-201-4-135 connection with the sale of products or Standard White(Grey White) parts of products.TFSBP shall not be (RAL9002) P/N 56-201-5-135 responsible for sprinkler system design * Eastern Hemisphere sales only. errors or inaccurate or incomplete in- •• Previously known as Bright White. formation supplied by Buyer or Buyer's Note: All Custom Cover Plates are representatives. painted using Sherwin Williams Interior t In no event shall TFSBP be liable,in con- Latex Paint. Contact TYCO Customer tract,tort,strict liability or under any oth- Service with any questions related to er legal theory,for incidental, indirect, custom orders. special or consequential damages, in- t cluding but not limited to labor charg- Sprinkler Wrench es,regardless of whether TFSBP was Specify W-Type 18 Sprinkler Wrench, informed about the possibility of such P/N 56-000-1-265. damages,and in no event shall TFSBP's liability exceed an amount equal to the +' sales price. The foregoing warranty is made in lieu of any and all other warranties.express or implied,including warranties of mer- chantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on fail- ure of or defect in products,materials or components,whether the claim is made in contract,tort,strict liability or any oth- er legal theory. This warranty will apply to the full extent permitted by law.The invalidity,in whole or part,of any portion of this warranty will not affect the remainder. 9 S TFP443 Page 6 of 6 1 Copyright®2010 Tyco Fire Suppression&Building Products.All rights reserved. i 1 1 v tCO Fire Suppression , & Building Products rapid response. Technical Services 800-381-93121+1-401-781-8220 HOME FIRE SPRINKLER SYSTEM $ www.tyco-fire.com f Series LFII Residential Sprinklers s k 4.9 K-Factor Pendent and Recessed Pendent k Wet Pipe and Dry Pipe Systems t { i General The Listing for the Series LFII Residential Pendent and Recessed Pendent Sprinklers now offers Description the laboratory approved option of The TYCO RAPID RESPONSE Series designing dry pipe residential sprinkler I LFII Residential Pendent and Recessed systems. Pendent Sprinklers(TY2234)are deco- Through extensive testing,it has been f rative, fast response, frangible bulb determined that the number of design i L .... sprinklers designed for use in residen- sprinklers (hydraulic design area) for , tial occupancies such as homes,apart- the Series LFII Residential Pendent and ments,dormitories,and hotels.When Recessed Pendent Sprinklers(TY2234) •`= aesthetics and optimized flow charac- need not be increased over the number ;' teristics are the major consideration, of design sprinklers(hydraulic design the Series LFII Residential Sprinklers area)as specified for wet pipe sprinkler should be the first choice. systems,as is accustomed for density/ The Series LFII Residential Sprinklers area sprinkler systems designed per are intended for use in the following NFPA 13. NOTICE scenarios: Consequently, the Series LFII The Series LFII Residential Pendent • wet and dry pipe residential sprinkler Residential Sprinklers offer the features and Recessed Pendent Sprinklers systems for one- and two-family of non-water filled pipe in addition to y y not having to increase the number of (TY2234) described herein must be dwellings and mobile homes per design sprinklers (hydraulic design ance with this document and the appli- area)13D pli- area) for systems designed to NFPA • wet and dry pipe residential sprinkler 13, 13D,or 13R. Non-water filled pipe Protection standards of the National to systems for residential occupancies will permit options for areas sensitive the standards dsof ntiau, in addition to up to and including four stories in to freezing. the standards of any authorities having height per NFPA 13R jurisdiction.Failure to do so may impair These Sprinklers have a 4.9 (70,6) the performance of these devices. • wet and dry pipe sprinkler systems K-Factor that provides the required for the residential portions of any residential flow rates at reduced Owners are responsible for main- occupancy per NFPA 13 pressures,enabling smaller pipe sizes taining their fire protection system and and water supply requirements. devices in proper operating condition. Historically residential sprinklers, The installing contractor or sprinkler i. based on their Listing, have been The recessed version of the Series manufacturer should be contacted with limited to wet pipe sprinkler systems LFII Residential Sprinklers is intended any questions. t to assure speed of water delivery for a for use in areas with finished ceilings. given prescribed design area(number It employs a two-piece Style 20 of design sprinklers). Recessed Escutcheon. The Recessed Escutcheon provides 1/4 inch(6,4 mm)of recessed adjust- ment or up to 1/2 inch (12,7 mm) of IMPORTANT total adjustment from the flush ceiling Always refer to Technical Data position.The adjustment provided by A t Sheet lwa TFP700 for the "INSTALLER the Recessed Escutcheon reduces the WARNING" that provides cautions the sprinklers must be c nipples to cut. with respect to handling and instal- lation of sprinkler systems and The Series LFII Residential Pendent k' components.Improper handling and and Recessed Pendent Sprinklers have installation can permanently damage been designed with heat sensitivity a sprinkler system or its components and water distribution characteristics I and cause the sprinkler to fail to proven to help in the control of residen- operate in a fire situation or cause it tial fires and to improve the chance for to operate prematurely. occupants to escape or be evacuated. z b Page 1 of 8 AUGUST 2011 TFP400 , • TFP400 Page 2 of 8 WET PIPE SYSTEM • Minimum Flow and Residual Pressure(b) Maximum Maximum For Horizontal Coverage Spacin g Ceiling(c,d,e) For Sloped Ceiling(c,d,e) For Sloped Ceiling(c,d,e) Area(a) Ft. (Maximum 2-Inch Rise (Greater than 2-Inch Rise up to (Greater than 4-Inch Rise up to Ft.x Ft. (m) for 12-Inch Run) Maximum 4-Inch Rise for 12-Inch Run) Maximum 8-Inch Rise for 12-Inch Run) (m x m) 155°F(68°C)or 155°F(68°C) 175°F(79°C) 155°F(68°C) 175°F(79°C) 175°F(79°C) 12 x 12 12 13 GPM(49,2 LPM) 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) (3,7 x 3,7) (3,7) 7.0 psi(0,48 bar) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 14 x 14 14 13 GPM(49,2 LPM) 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) (4,3 x 4,3) (4,3) 7.0 psi(0,48 bar) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 16 x 16 16 13 GPM(49,2 LPM) 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) (4,9 x 4,9) (4,9) 7.0 psi(0,48 bar) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 18 x 18 18 17 GPM(64,3 LPM) 17 GPM(64,3 LPM) 17 GPM(64,3 LPM) 17 GPM(64,3 LPM) 17 GPM(64,3 LPM) (5,5 x 5,5) (5,5) 12.0 psi(0,83 bar) 12.0 psi(0,83 bar) 12.0 psi(0,83 bar) 12.0 psi(0,83 bar) 12.0 psi(0,83 bar) 20 x 20 20 20 GPM(75,7 LPM) 20 GPM(75,7 LPM) 20 GPM(75,7 LPM) 21 GPM(79,5 LPM) 22 GPM(83,3 LPM) (6,1 x 6,1) (6,1) 16.7 psi(1,15 bar) 16.7 psi(1,15 bar) 16.7 psi(1,15 bar) 18.4 psi(1,27 bar) - 20.2 psi(1,39 bar) (a) For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (1)) The Minimum Flow requirement is based on minimum flow in GPM(LPM)from each sprinkler.The associated residual pressures are calculated using the nominal K-Factor.Refer to Hydraulic Design under the Design Criteria section. (c) For NFPA 13D 2010 applications,Horizontal Ceiling criteria shall be used for certain sloped ceiling configurations up to 8:12 pitch. Refer to TIA 1028R for allowed sloped ceiling limitations when using horizontal ceiling criteria. (d) For NFPA 13R applications,Horizontal Ceiling criteria may be used for sloped ceiling configurations up to 8:12 pitch when acceptable to the Local Authority Having Jurisdiction. (e) For NFPA 13 residential applications,the greater of 0.1 GPM/Ft 2 over the design area or the flow in accordance with the criteria in Table A must be used. TABLE A SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS(TY2234) NFPA 13, 13D AND 13R HYDRAULIC DESIGN CRITERIA WET PIPE SYSTEMS DRY PIPE SYSTEM Minimum Flow and Residual Pressure(b) Maximum Maximum For Horizontal Ceiling(C) Coverage Area(a) Spacing (Maximum 2-Inch Rise for 12 Inch Run) Ft.x Ft.(m x m) Ft.(m) 155°F(68°C) 175°F(79°C) 12 x 12 12 13 GPM(49,2 LPM) 13 GPM(49,2 LPM) (3,7 x 3,7) (3,7) 7.0 psi(0,48 bar) 7.0 psi(0,48 bar) 14 x 14 14 14 GPM(53,0 LPM) 14 GPM(53,0 LPM) (4,3 x 4,3) (4,3) 8.2 psi(0,57 bar) 8.2 psi(0,57 bar) 16 x 16 16 15 GPM(56,8 LPM) 15 GPM(56,8 LPM) (4,9 x 4,9) (4,9) 9.4 psi(0,65 bar) 9.4 psi(0,65 bar) 18 x 18 18 18 GPM(68,1 LPM) 18 GPM(68,1 LPM) (5,5 x 5,5) (5,5) 13.5 psi(0,93 bar) 13.5 psi(0,93 bar) 20 x 20 20 21 GPM(79,5 LPM) 21 GPM(79,5 LPM) (6,1 x 6,1) (6,1) 18.4 psi(1,27 bar) 18.4 psi(1,27 bar) (a) For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) The Minimum Flow requirement is based on minimum flow in GPM(LPM)from each sprinkler.The associated residual pressures are calculated using the nominal K-Factor.Refer to Hydraulic Design under the Design Criteria section. (c) For NFPA 13D 2010 applications,Horizontal Ceiling criteria shall be used for certain sloped ceiling configurations up to 8:12 pitch. Refer to TIA 1028R for allowed sloped ceiling limitations when using horizontal ceiling criteria. k TABLE B 1 SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS(TY2234) NFPA 13D HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEMS f 1 • f TFP400 Page3of8 P I 7/16"(11,1 mm) ESCUTCHEON 1/2" Components: NOMINAL PLATE SEATING _ 2-7/8"DIA. 1 Frame MAKE-IN NPT SURFACE (73,0 mm) 2 - Button 3 Sealing Assembly 1 4- Bulb 14,1114 �_5 Compression 2 I■r`'.Screw � �- . 2-1/4" f: :::- Defe 3 41, � ����1 (57,2 mm) �� ����� t IL 4 I 1-5/8" (41,3 mm) WRENCH ' STYLE 20 a < RECESSED 5 1�` FLATS . ESCUTCHEON 9 indicated on 6 �° — _._..---.._._.. „_._..---.._._.. Deflector. CROSS SECTION PENDENT RECESSED PENDENT (` ( FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS(TY2234) I 2-7/8"DIA. 7/16±1/8" (73,0 mm) 1/2"(12,7 mm) 4.c.,, (11,1±3,2 mm) 2-1/4"DIA. 1/4"(6,4 mm) WRENCH RECESS (57,2 mm) FACE OF (END"A"USED SPRINKLER MOUNTING FOR TY2234) FITTING PLATE FIGURE 3 .. I W-TYPE 6 /i GOOK W , SPRINKLER WRENCH j , "Miff MI Mr t \ .. ....■a-. MOUNTING SURFACE Ill 1/8" WRENCH . (3,2 mm) RECESS i CLOSURE TY2234 1-3/8"(34,9 mm) r,>1 1-1/8"(28,6 mm) i r FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE SERIES LFII RESIDENTIAL PENDENT SPRINKLERS(TY2234) ' PUSH WRENCH IN TO ENSURE l ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH r i TFP400 • Page 4 of 8 • Model/Sprinkler Note: When conditions exist that are outside the scope of the provided A criteria, refer to the Residential Identification Sprinkler Design Guide TFP490 for �? it Number (SIN) the manufacturer's recommendations that may be acceptable to the local TY2234 authority having jurisdiction. ,n co Ti Technical System Types Per the UL Listing, wet pipe and dry 7 pipe systems may be utilized. Per the Data C-UL Listing, only wet pipe systems \vI ;i\� may be utilized. i Approvals • For dry systems corrosion-resistant • UL Listed for use with wet pipe and or internally galvanized pipe shall TY2234 dry pipe systems be utilized with the sprinklers de- • C-UL Listed for use only with wet scribed in this data sheet. B pipe systems • For dry systems not using CPVC, Z• NYC Approved under MEA 44-03-E pendent sprinklers shall be installed iI on return bends, where the sprin-For details on these approvals,refer klers, return bends, and branch E E to the Design Criteria section. line piping (that is, potential areas Maximum Working Pressure for trapped water)are in areas at or 4°C 40°F bove ( ).175 psi(12,1 bar) a Discharge Coefficient Refer to technical data sheet TFP485 Disch Gge Coefficient cie,6 LPM/barti2) about the use of Residential Sprinklers in residential dry pipe systems. l�i, Temperature Rating 155°F(68°C)or 175°F(79°C) NOTICE MAXIMUM TY2234 Finishes When corrosion-resistant or inter- ONE-HALF B • White Polyester nally galvanized pipe and fittings with WIDTH PLUS a potable water supply is utilized, 2"(50,8 mm) • Chrome Plated return bends need not be installed. • Natural Brass However,any portion of the piping that FIGURE 5 has the potential to trap water must SPRINKLER POSITIONING Physical Characteristics be maintained at or above 40°F(4°C) S PRI NKPRIMARYBEAM Frame Brass unless provision to drain such areas is UNDEIPE SYSTEMS ONLY Button Bronze provided and maintained dry. Sealing Assembly Beryllium (Refer to the "Beam Ceiling g y ry Design Criteria"section.) Nickel w/Teflon' Water Delivery When using the Series LFII Residential Bulb(3 mm) Glass Pendent and Recessed Pendent Compression Screw Bronze Sprinklers (TY2234) in dry pipe NOTICE Deflector Bronze sprinkler systems, the requirements The number of "design sprinklers" Ejection Spring Stainless Steel for "Dry System Water 2010 edition specified in NFPA 13D and 13R for wet 1 P 9 Section 8.3.4.3 of the 2010 edition of NFPA 13D apply. For a residential pipe systems is to be applied when hazard, in no case shall the time of designing dry pipe systems. There is Operation water delivery exceed 15 seconds for no need to increase the design area,as The glass Bulb contains a fluid that the most remote operating sprinkler. is the case for density/area systems,in expands when exposed to heat.When accordance with U.S.Patent 7,712,543. the rated temperature is reached,the Hydraulic Design Refer to technical data sheet TFP485. fluid expands sufficiently to shatter the (NFPA 13D and 13R) glass Bulb, allowing the sprinkler to The minimum required sprinkler activate and flow water. flow rate for systems designed to NFPA 13D or NFPA 13R are given in Tables A and B as a function Design of temperature rating and the maximum allowable coverage areas. Criteria The sprinkler flow rate is the minimum The RAPID RESPONSE Series LFII required discharge from each of the Residential Pendent and Recessed total number of"design sprinklers"as Pendent Sprinklers (TY2234)are UL specified in NFPA 13D or NFPA 13R. and C-UL Listed for installation in accordance with the following criteria. `Registered trademark of Dupont 1 I I TFP400 Page 5 of 8 ▪ i ALL FIGURES: A—•-i--.—A—�-••—A--.--1 14"(356 mm) DISTANCES ARE f s` f MAXIMUM MEASURED TO ▪ 1 COMPARTMENT �ua�6;sv 6Mgint w f WALL FACES AND . I . ) TO CENTERLINES �1 " A=3'-4'to 6'-0"(1,0 to 1,8 m)OF BEAMS A A_ FOR PRIMARY BEAMS HAV- ING A 14"(356 mm)MAXIMUM ;� DEPTH ( PRIMARY St ): BEAM a 20'-0'(6,1 m) ( Alit 3 MAXIMUM t COMPARTMENT 1 a T WALLS VtiVMEIRE?Z?T WSS V.SVV4E sgVPSss y' FIGURE 6A PRIMARY BEAM SPANS UP TO 20'-0"(6,1 m) i A—.-t•—A_- - A--.--1 \ >` F F \ s �a ��f5t, B A=3'-4'to 6'-0'(1,0 to 1,8 m) _'�_1 1 DEPTH 'A(3 6 EA MS HAV- 1 fi SECONDARY B ING A 14'(356 mm)MAXIMUM BEAM �� � B=20'-0"(6,1 m)MAXIMUM i...... FOR SECONDARY BEAMS THAT ARE TO BE EQUAL IN PRIMARY Ilk -`-` DEPTH TO PRIMARY BEAMS : BEAM 1, AND THAT MUST BE IN PLACE f �— •— — — SO THAT PRIMARY BEAM , , , POCKETS DO NOT EXCEED p 20'-0'(6,1 m) ( COMPARTMENT 1 WALLS A.i .£ ..°_a ",_'...:6-.;-'''v;- ,, «, FIGURE 68 PRIMARY BEAM SPANS GREATER THAN 20'-0'(6,1 m) A —A —A \ A=3'-4'to 6.-0"(1,0 to 1,8 m) C FOR PRIMARY BEAMS HAV- q. ING A 14'(356 mm)MAXIMUM SECONDARY -1_.1_11- C DEPTH BEAM iitc Ii■ l■ ■■••■' j C=3'-4'(1,0 m)MINIMUM FOR SECONDARY BEAMS HAVING ), ''‘ Ilk DEPHS GREATER OF PTRIMARY BEAMS AN 25% PRIMARY* 1s, __ —A —or— €: BEAM C=ANY DISTANCE FOR SEC- *REFER TO ii 1 DEPTHS UP TO 25%OF 1 PRIMARY BEAMS FIGURE 68 COMPARTMENT a FOR SPANS WALLS '66A--V8ZAcsax:66eA'a.E x ZA6 16 EXCEEDING 20'-0"(6,1 m) FIGURE 6C COMBINATIONS OF PRIMARY AND SECONDARY BEAMS r t FIGURE 6 BEAM ARRANGEMENTS WET PIPE SYSTEMS ONLY FI (Refer to the "Beam Ceiling Design Criteria"section.) E Gr i y` TFP400 Page 6 of 8 * SECONDARY e`AVA � � , fg� � g" BEAM 1-'1_.'_N_e * :i� 16=1.0 � \ *USE DISTANCES SHOWN PRIMARY U FIGURES CE SHOWN W BEAM EXCEPT MEASUREMENTS _ ,. ARE TAKEN FROM FACES OF SOFFITS INSTEAD OF FROM WALL S SURFACES ENT FACE OF ,1 SOFFIT A t Vi 4 Iii COMPARTMENT 4 e 4 WALLS _nk �' ",': ��rk � 1 � i FIGURE 7 BEAM AND SOFFIT ARRANGEMENTS WET PIPE SYSTEMS ONLY (Refer to the"Beam Ceiling Design Criteria"section.) Hydraulic Design(NFPA 13) Operational Sensitivity Beam Ceiling For systems designed to NFPA 13, For Horizontal Ceilings (maximum the number of design sprinklers is 2-inch rise for 12-inch run),the sprin- Design Criteria to be the four most hydraulically klers are to be installed with a deflector- demanding sprinklers. The minimum to-ceiling distance of 1-3/8 to 4 inches required discharge from each of the or in the recessed position using only The RAPID RESPONSE Series LFII four sprinklers is to be the greater of the Style 20 Recessed Escutcheon as Residential Pendent and Recessed the following: Pendent Sprinklers (TY2234) are UL g shown in Figure 2. and C-UL Listed for installation in wet • The flow rates given in Tables A or B pipe systems only for residential occu- of NFPA 13D and 13R as a function NOTICE of temperature rating and the maxi- pancies with horizontal ceilings(that is, mum allowable coverage area. The "Beam Ceiling Design Criteria slopes up to a 2-inch rise over a 12-inch section permits deflector-to-ceiling run) with beams when installed in • A minimum discharge of 0.1 GPM/ distances up to 15-3/4 inches. accordance with the following criteria. sq. ft. over the "design area com- prised of the four most hydraulical- To help avoid obstructions to water General Information ly demanding sprinklers for actual distribution, a maximum 12-inch The basic concept of this protection coverage areas protected by the deflector-to-ceiling distance is scheme is to locate the sprinklers four sprinklers. permitted for NFPA 13D and NFPA on the underside of the beams, refer 13R applications where the sprinklers Figure 5,(not in the beam pockets);to NOTICE are located in closets. identify the main beams that princi- The number of "design sprin- For Sloped Ceilings (greater than pally run in one direction as"primary klers" specified in NFPA 13 for wet 2-inch rise up to 8-inch rise for 12- beams"; and, to identify the beams pipe systems is to be applied when inch run), the sprinklers are to be that run principally perpendicular to designing dry pipe systems. There is installed with a deflector-to-ceiling the main beams, as may be present distance of 1-3/8 to 4 inches or in the no need to increase the design area,as (or in some cases may be necessary is the case for density/area systems,in recessed position using only the Style for proper sprinkler protection), as accordance with U.S.Patent 7,712,543. 20 Recessed Escutcheon as shown in "secondary beams". Refer to technical data sheet TFP485. Figure 2. Sprinkler Spacing Primary and Secondary Beam Obstruction to Water Distribution. Types The minimum spacing between sprin- Sprinklers are to be located in accor- klers is 8 feet (2,4 m). The maximum Solid surface, solid or hollow core, dance with the obstruction rules of spacing between sprinklers cannot combustible or non-combustible. NFPA 13D,13R,and 13 as applicable exceed the length of the coverage area for residential sprinklers as well as (Table A)being hydraulically calculated; Primary and Secondary Beam with the obstruction criteria described maximum 12 feet for a 12 ft. x 12 ft. Positioning within the TYCO technical data sheet coverage area,or 20 feet fora 20 ft.x Directly attached to the underside of TFP490. 20 ft.coverage area. a combustible or non-combustible 3 smooth ceiling at any elevation. i 1 TFP400 Page 7 of 8 - Primary Beam Cross-Section Sprinkler Position Obtain a leak-tight 1/2 inch NPT Maximum depth of 14 inches and the The deflector to bottom of primary sprinkler joint by applying a minimum- maximum width is unlimited.The cross- beams for the Series LFII Pendent and to-maximum torque of 7 to 14 ft. lbs. f sectional shape of the primary beam Recessed Pendent Sprinklers(TY2234) (9,5 to 19,0 Nm).Higher levels of torque may be rectangular to circular. is to be 1-1/4 to 1-3/4 inches (Figure can distort the sprinkler Inlet with Seconds Beam Cross-Section 5A). The vertical center-line of the consequent leakage or impairment of Series LFII Pendent Sprinklers is to be the sprinkler. Maximum depth to be no greater than no greater than half the primary beam the primary beam and the maximum Do not attempt to compensate a width is unlimited.The cross-sectional cross-sectional width plus 2 inches for insufficient adjustment in an shape of the secondary beam may be from the centerline of the primary beam Escutcheon Plate b under- or over- 5 P rY Y Y rectangular to circular. (Figure 56). tightening the Sprinkler Re-adjust the Primary Beam Spacing NOTICE position of the sprinkler fitting to suit. I The primary beams(Figure 6A)are to Core drilling of beams to allow the Series LFII Residential Pendent be 3 ft.-4 in.to 6 ft.from the compart- installation of sprinkler drops requires Sprinklers ment wall to center of the nearest beam consulting with a structural engineer. The Series LFII Residential Pendent and from center to center between Where core drilling is not permitted, Sprinklers must be installed in accor- beams. the previously stated sprinkler position dance with the following instructions. I' criteria for the Series LFII Residential 1. Install p Secondary Beam Spacing pendent s rinkle d in the Pendent and Recessed Pendent Y The secondary beams principally run Sprinklers(TY2234)allows placement Pendent position with the deflector perpendicular to the primary beams. parallel to the ceiling. Secondary beams of a depth equal to of the sprinkler drop adjacent to the the primary beam must be placed so primary beam. 2. With pipe-thread sealant applied to that the beam pockets created by the the pipe threads, hand-tighten the Beam and Soffit Arrangements sprinkler into the s primary beams do not exceed 20 feet rangements pprinkler fitting. A in length(Figure 6B). soffit is permitted to be placed around 3. Tighten the sprinkler into the I the perimeter of a compartment with sprinkler fitting using only the the beam arrangement within the NOTICE soffited area(Figure 7). 3)Type 6 Sprinkler Figure (Figure When the beam pockets created by 3).With reference to Figure 1,apply the primary beams exceed 20 feet in The cross-section of the soffit may be the W-Type 6 Sprinkler Wrench to length, the installation will require the any size as long as it does not create the wrench flats. use of secondary beams as described an obstruction to water distribution above. Otherwise, secondary beams per the obstruction rules of NFPA 13 for Series LFII Residential Recessed need not be present. residential sprinklers. Pendent Sprinklers When soffits are present, the prev-i The Series LFII Residential Recessed Secondary beams of a cross-sectional ously provided 3 ft.-4 inches to 6 ft. Pendent Sprinklers must be installed depth greater than one-quarter the y p in accordance with the following depth of the primary beams are to be a "compartment wall to adjacent beam" owg distance for the primary instructions. minimum of 3 ft. - 4 inches from the p � ary and secondary compartment wall to center of the beams is to be measured from 1. Install recessed pendent sprinklers nearest beam and from center to center the face of the soffit as opposed to in the pendent position with the between beams(Figure 6C). the compartment wall. deflector parallel to the ceiling. Secondary beams of a cross-sectional Note: Although the distance to the 2. After installing the Style 20 Mounting depth no greater than one-quarter the beams is measured from the face of Plate over the sprinkler threads depth of the primary beams may be the soffit, the sprinkler coverage area and with pipe-thread sealant applied f, placed at any compartment wall to is to be measured from the compart- to the pipe threads, hand-tighten i center of the nearest beam distance ment wall. the sprinkler into the sprinkler fitting. and from any center to center distance 3. Tighten the sprinkler into the sprin- between beams(Figure 6C). Installation kier fitting using only the W-Type 7 Lintels Recessed Sprinkler Wrench(Figure Lintels over doorwa s exitin The RAPID RESPONSE Series LFII 4). With reference to Figure 1, I the compartment must be presentg Residential Pendent and Recessed apply the W Type 7 Recessed The minimum height for the lintels is Pendent Sprinklers(TY2234)must be Sprinkler Wrench to the sprinkler I 8 inches or no less than the depth of the installed in accordance with the wrench flats. Primary Beams,whichever is greater. following instructions. 4. After the ceiling has been installed Y NOTICE or the finish coat has been applied, s, Sprinkler Types slide on the Style 20 Closure over Series LFII Pendent and Recessed Do not install any bulb type sprinkler if the Series LFII Residential Sprinkler Pendent Residential Sprinklers the bulb is cracked or there is a loss of and push the Closure over the (TY2234), 155°F (68°C) and 175°F liquid from the bulb. With the sprinkler Mounting Plate until its flange (79°C). held horizontally, a small air bubble comes in contact with the ceiling. should be present. The diameter of the Sprinkler Coverage Area and Hy- air bubble is approximately 1/16 inch draulic Design (1,6 mm). The sprinkler coverage areas and hydraulic design criteria as presented in the Table A for "Horizontal Ceilings"are to be applied. f t r i I t TFP400 Page 8 of 8 Care and Responsibility lies with the owner for This limited warranty sets forth the the inspection, testing, and mainte- exclusive remedy for claims based Maintenance nance of their fire protection system on failure of or defect in products, and devices in compliance with this materials or components,whether the The RAPID RESPONSE Series LFII document, as well as with the appli- claim is made in contract, tort, strict Residential Pendent and Recessed cable standards of the National Fire liability or any other legal theory. Pendent Sprinklers(TY2234)must be Protection Association(that is, NFPA This warranty will apply to the full maintained and serviced in accordance 25),in addition to the standards of any extent permitted by law.The invalidity, with the following instructions. authorities having jurisdiction.Contact in whole or part,of any portion of this the installing contractor or sprinkler warranty will not affect the remainder. NOTICE manufacturer regarding any questions. Before closing a fire protection system Automatic sprinkler systems are Ordering main control valve for maintenance recommended to be inspected, work on the fire protection system tested,and maintained by a qualified Procedure that it controls, obtain permission to Inspection Service in accordance with shut down the affected fire protection local requirements and/or national Contact your local distributor for systems from the proper authorities codes. availability. When placing an order, and notify all personnel who may be indicate the full product name and Part affected by this action. Limited Number(P/N). Absence of the outer piece of an Sprinkler Assembly escutcheon, which is used to cover Warranty Specify Series LFII Residential Pendent a clearance hole, can delay sprinkler and Recessed Pendent Sprinkler operation in a fire situation. Products manufactured by Tyco Fire (TY2234), r , K 9ith (temperature Suppression & Building Products ) =4. , w (em p Owners must assure that the sprin- (TFSBP) are warranted solely to the rating),(finish),and P/N(below). klers are not used for hanging of any original Buyer for ten(10)years against 155°F(68°C)or objects and that the sprinklers are only defects in material and workmanship Chrome Plated P/N 51-201-9-155 cleaned by means of gently dusting when paid for and properly installed 155°F(68°C) with a feather duster;otherwise,non- and maintained under normal use White Polyester P/N 51-201-4-155 operation in the event of a fire or Thad- and service.This warranty will expire 155°F(68°C) vertent operation may result. ten (10) years from date of shipment White P/N 51-201-3-155 by TFSBP. No warranty is given for (RAL9010)' Exercise care to avoid damage to products or components manufac- 155°F(68°C) sprinklers before, during, and after p p Natural Brass P/N 51-201-1-155 installation. Never paint, plate, coat, tured by companies not affiliated by 175°F(79°C)or or otherwise alter automatic sprinklers ownership with TFSBP or for products Chrome Plated P/N 51-201-9-175 after they leave the factory. and components which have been 175°F(79°C) subject to misuse, improper instal- White Polyester P/N 51-201-4-175 Replace sprinklers that: lation, corrosion, or which have not 175°F(79°C) • were modified or over-heated. been installed, maintained, modified White or repaired in accordance with appli- (RAL9010)' P/N 51-201-3-175 • were damaged by dropping,striking, cable Standards of the National Fire 175°F(79°C) wrench twisting,wrench slippage,or Protection Association, and/or the Natural Brass P/N 51-201-1-175 the like. standards of any other Authorities 'Eastern Hemisphere sales only. • are leaking or exhibiting visible signs Having Jurisdiction. Materials found by I of corrosion. TFSBP to be defective shall be either Recessed Escutcheon • were exposed to corrosive repaired or replaced,at TFSBP's sole Specify Style 20 Recessed Escutcheon products of combustion but have option. TFSBP neither assumes, nor with finish and P/N.Refer to Technical not operated, if you cannot easily authorizes any person to assume for Data Sheet TFP770. remove combustion by-products it, any other obligation in connection with a cloth. with the sale of products or parts of Sprinkler Wrench • have a cracked bulb or have lost products.TFSBP shall not be respon- Specify W-Type 6 Sprinkler Wrench, liquid from the bulb. Refer to the sible for sprinkler system design errors P/N 56-000-6-387. Installation section in this data sheet. or inaccurate or incomplete infor- mation supplied by Buyer or Buyer's Specify W-Type 7 Sprinkler Wrench, Initial and frequent visual inspections of representatives. P/N 56-850-4-001. random samples are recommended for In no event shall TFSBP be liable, in corrosion-resistant sprinklers to verify contract, tort, strict liability or under the integrity of the corrosion-resistant any other legal theory, for incidental, material of construction. Thereafter, indirect, special or consequential annual inspections per NFPA 25 should damages, including but not limited to suffice. labor charges, regardless of whether Inspections of corrosion-resis- TFSBP was informed about the possi- tant sprinklers are recommended at bility of such damages, and in no close range, instead of from the floor event shall TFSBP's liability exceed an level per NFPA. Inspection at close amount equal to the sales price. range can better determine the exact The foregoing warranty is made in sprinkler condition and the long-term lieu of any and all other warranties, integrity of the corrosion-resistant express or implied.including warran- material,which can be affected by the ties of merchantability and fitness for a corrosive conditions present. particular purpose. Copyright 0 2006-2011 Tyco Fire Suppression&Building Products.All rights reserved. 1 Y e ES-A-4000B ( Series 4000B A M E S Reduced Pressure Zone Assemblies FIRE&`""TER`"ORKS 1 Sizes: 1/2"-2" (15-50mm) c a. d `'. . c /' a;V. 2"(50mm)4000B-HC '/:N(15mm)4000B Features Series 4000B Reduced Pressure Zone Assemblies are designed to protect • Single access cover and potable water supplies in accordance with national plumbing codes and wa- r modular check construction ter authority requirements.This series can be used in a variety of installa- for ease of maintenance tions, including the prevention of health hazard cross connections in piping f systems or for containment at the service line entrance. • Top entry-all internals t immediately accessible This series features two in-line, independent check valves,captured springs • and replaceable check seats with an intermediate relief valve. Its compact Captured springs for safe modular design facilitates easy maintenance and assembly access. Sizes maintenance • Internal relief valve for reduced '/2"- 1" (15-25mm)shutoffs have tee handles. installation clearances • Replaceable seats for Specifications economical repair • Bronze body construction for A Reduced Pressure Zone Assembly shall be installed at each potential durability- t/2" to 2" (15-50mm) health hazard location to prevent backflow due to backsiphonage and/or backpressure.The assembly shall consist of an internal pressure differential • Ball valve test cocks- relief valve located in a zone between two positive seating check modules screwdriver slotted -t/" to 2" with captured springs and silicone seat discs.Seats and seat discs shall be } (15-50mm) replaceable in both check modules and the relief valve.There shall be no • Large body passages provides threads or screws in the waterway exposed to line fluids. Service of all inter- low pressure drop nal components shall be through a single access cover secured with stain- • Compact, space saving design less steel bolts.The assembly shall also include two resilient seated isolation • No special tools required for valves, four resilient seated test cocks and an air gap drain fitting.The as- servicing sembly shall meet the requirements of: USC Manual 8th Editiont;ASSE Std. 1013;AWWA Std. C511; CSA 864.4.The assembly shall be an Ames Com- pany Series 4000B. Job Name Contractor Job Location Approval Engineer Contractor's P.O.No. ; Approval Representative Ames product specifications in U.S.customary units and metric are approximate and are provided for reference only For precise measurements,please contact Ames Technical Service.Ames reserves the right to change or modify product design,construction,specifications,or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.amesfirewateccom t I r l- ; 4 • Materials Pressure — Temperature Bronze body construction,silicone rubber disc material in the Suitable for supply pressures up to 175psi(12.06 bar) first and second check plus the relief valve. Replaceable poly- and water temperature to 180°F(75°C)continuous. . mer check seats for first and second checks.Removable stain- less steel relief valve seat.Stainless steel cover bolts. Standardly furnished with NPT body connections.For optional Available Models • bronze union inlet and outlet connections,specify prefix U Suffix: Ch"-2"X15-50mm).Series 4000B furnished with quarter turn, B -quarter-turn ball valves full port,resilient seated,bronze ball valve shutoffs. LBV -less ball valves Standards LH -locking handle ball valves(open position) AWWA C511-92,USC Manual 8th Edition,IAPMO File No.1563 SH -stainless steel ball valve handles HC -21/2" inlet/outlet fire hydrant fitting(2"valve) Approvals S -bronze strainer ® C S A• "w w s/„. Prefix: c �L us U -union connections C US 1013 B64.4 3/4"-2"(20-50mm) (LBV models only) Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Approval models QT,U. IMPORTANT:Inquire with governing authorities for local installation requirements. Weights — Dimensions — .:a - ® C 7511- I am■ ij li e 313*IT t 11) hJdV.11 I 'I'l ' I 11 E---iiii.E. '.0 N • • — I — Li L ), �J -41(----M- 30- it A • Suffix HC- Fire Hydrant Fittings dimension "A" =251/1s (637mm) MODEL SIZE(DN) DIMENSIONS STRAINER DIMENSIONS WEIGHT A B C D L M N in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kg. au.. * MIIIIIWZIIEMIIIIIIIIIIMMIIIIIMIMMIW11111 4. . .1 ,u1: IMPI 1 EIll M' EWM IM ' 2.. 40006 M2" 1 25 1634 425 5' 140 3 76 11W111 9' 241 WM= 2 1s 59 12.25 5.6 4110B" : � ' 'r '9 c. t1 1' 14..2 44108" r '1 � ' IC 'EII 1.. 2 7.4 40008" 2 50 FIIMIIM 7 4 197 IMES 3'4 83 IMOMMI 6316 157 41 124 30.00 13.6 Strainer sold separately "Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. 2 r i Capacity • 1 Performance as established by an independent testing laboratory. *Typical maximum system flow rate(7.5 feet/sec.,2.3 meters/sec.) g` { I t kPa psi '/4" (8mm) kPa 138 20 Psi 1" (25mm) vto * E 0 117 17 o 207 30 25 i F, 76 11 = 138 20 I g 55 8 _ E 103 15 d 35 5 _ a 69 10 ftP 0 .25 .50 .75 1 1.17 gpm 34 5 0 .95 1.9 2.9 3.8 4.5 Ipm 0 0 0 5 10 20 30 40 50 60 70 80 gpm a Flow Rate "P 0 19 38 76 114 152 190 228 266 304 Ipm r 7.5 15 fps 2.3 4.6 mps f Flow Rate kPa psi %" (1Omm) kPa psi 1W (32mm) y 138 20 y 172 25 cn 117 17 3 k J J 138 20 E 96 14 �� �- E 103 15 H 76 11 0 69 10 E55 8 E d 35 5 0. 34 5 �p 0 .25 .50 .75 1 1.25 1.50 2.5 3.1 gpm 0 0 - 0 .95 1.9 2.9 3.8 4.8 5.7 9.5 11.8 Ipm 0 10 20 30 40 50 60 70 80 gg Flow Rate p AP 0 38 76 114 152 190 228 266 304 Ipm 5 7.5 10 15 fps i; 1.5 2.3 3.0 4.6 mps =` Flow Rate E kPa psi '/2" (15mm) 1'/2" (4Omm) vt 172 25 2207 3300 * - - - o 138 20 �C J 172 25 E 103 15 E 138 20 q 69 10 0 103 15 i E 0. 355 1 69 10 I 0. 345 { Ap 0 1 2.5 5 7.5 10 12.5 15 gpm 0 0 - - d 0 3.8 9.5 19 28.5 38 47.5 57 Ipm pp 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 5 7.5 15 fps 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 1.52.3 4.6 mps 5 7.5 10 15 fps Flow Rate 1.5 2.3 3.0 4.6 mps Flow Rate kPa psi * 3/4" (2Omm) 2" (5Omm) 207 30 M■■■■■■■M M ■M■ ■■■M■■MM■■ 207 30 207 30 H 165 24 ■■■■■■■MME■■■■■ME■■■■■IR o ■■■■■■■EM■■■M■■■M■■■EM■ q 172 25 -1124 18 ■■MM■■IMMMMUMMMMM.MalIMMIN J 138 20 E ■■■■M■■■■■■_■•!Mil•■■■■■■ 83 12 ���-iiisM■■■■■■■MINE E 103 15 q Al 6 IM■■■■■■■EM■EE■■■■■■■M■ » 69 10 ■■■■■■■IN■■■■■■M■■■■■■M■ » a 0 0 ��MMININ MN��M��MINENIMMEN�M 0. 34 5 - - O o 4 0 2 6 10 14 18 22 26 30 34 38 42 46 pp0 20 40 60 80 100 120 140 160 180 200 gpm 0 76 152 228 304 380 456 532 608 684 760 Ipm AP 0 7.6 23 38 53 68 84 99 114 129 144 160175 I 7.5 15 iPs 5 7.5 10 15 fps 2.3 4.6 mps 1.5 2.3 3.0 4.6 mps Flow Rate Flow Rate 4' 3 , For additional information, visit our web site at: www.amesfirewater.com A A M E S S09001 FIRE&WATERWORKS A Division of Watts Regulator Company www.amesfirewater.com CERTIFlED 1427 North Market Blvd. • Suite #9 • Sacramento, CA 95834 • Phone: 916-928-0123 • Fax: 916-928-9333 ES-A-4000B 0625 ©Ames Fire&Waterworks,2007 ffi., , ','W°.:,:,,,Iii• :;-rt 44, ,,,,,, ■ -1P- I-„,. ,—,`„„„, 4 - 1,:k - I' ' I-Pp.,---., ,.,I,41, ., ,,-14 ' z,.. i",' 'A )::„:1 i r, -.',!...% ' '' '''t.'k"IPP„ :,,4 `, I,44-IIIs.,,44 I2•I,,,, ItA P - -'''' ,''` 3' ' ' ■14'- iII -,,, --'IP*" ' 'z' , i.7i-- . ",,, : A>°■A 1 : ' ' 4 ff r i ; , :,. --, . ,t- 1 ' t I ji - .„,4.1-..w. - - 1 ' ,: - .., ' —L;ipr4, ......„, : ' f St' T . il, ° ! , 1 ._,*,,,, 1. . ,,. -fitl:„. ,-- kart4,.• ' ,- ,,,.,1 ;.,. t,f—r i : 1.!.. - j 4 ',I:1' I . ,t gallons intailec, -, 4 ,, , , ,,,,,- i i44: -i•.*- t' - " " ''' '''''' millions of 1 K ,,..,::, ......„ ,.,, ._,,, ,.., , 4 Time Tested... 15 years and ml Illo,, ‘•:,-,', ,,,r, 'T Fire .... • Igh er , ! t . ,:f ire ghter.,„ ,1 0,10.4.pnitieston siorovoi Freeze erinProtection esolutions fo r Fluid c Pv c sprinkler ; „ ,....,. 41T . .... ......, FireFighterTM PG .t 1.- , , Protection Fluid „......„ , .... ...„,, e Prate ,.....-00 FireFFreigze , E t 1 i' ., m oPropylene stwet f ireGslyocroi hi ksioelrutsiyosntsemfosr ri) Use [ Row <2 ht.**Protection roger .< isv tut*simitocillorkt '' t i — . 401 bona pirsisielf!t_serams01'' '' Ina 011U-otrtml*Nr,,,41,norZ Easy to t Available in 5 gallon containers,tank trucks gallon drums totes or , . Ready to use or concentrates P------ - -- :, ,. - I ..... --zr • Custom blends available Easy to Maintain .........,- ,, ,..., , IN'”' '''• 1 —.... 6., , Instruments test the necessary f lui fluids ehdprotection maintain the p to -- g. Hydrometer ....„ The Noble Company Refractometer 800-878- 5788 ,!:'r'.›..,..t.,,c.t.',..,, , ,,, '' - www.noblecompany.com , FreF[ght-r,s,a tr9d,r11r4 of Trh-Noble ComPl” Digital Refractometer PRODUCT DESCRIPTION FDA References • FireFighter GL and FireFighter PG are non-toxic*'anti- GRAS:FireFighter GL and FireFighter PG are consid- freezes designed specifically for fire protection systems. ered"Generally Regarded as Safe"(GRAS)by the Fed- These products are used in place of water and other wa- eral Food and Drug Administration. ter-like fluids in sprinkler systems where freezing may either cause damage or interfere with the functioning of systems or equipment,and/or toxicity to humans or ani- Typical Physical Properties of "Ready-to-Use" mals is a concern. FireFighter GL and FireFighter PG "Ready-to-Use" FireFighter GL FireFighter PG FireFighter GL Color: Orange Red FireFighter GL is a Glycerine based material which is compatible with all approved types of pipe,including Density @ 77°F: 1.137 1.026 BlazeMaster®CPVC sprinkler pipe and fittings. (grams/ml) Active Ingredient:USP or CP Glycerine Viscosity @ 77°F: 7.05 6.15 Other ingredients:Water (Centipoise) Viscosity Reduction Agent Dye pH: 7.0 8.0-9.6 Boiling Point @ Atmospheric Pressure: FireFighter PG (760 mm) 212°F 222°F FireFighter PG is a Propylene Glycol based material Minimum Flow which is compatible with all approved types of sprinkler Temperature: -15°F -15°F systems,with the exception of CPVC. Minimum Burst Active Ingredient:Propylene Glycol Temperature: -50°F -50°F Other Ingredients:Water (Hard Freeze) Viscosity Reduction Agent Inhibitor Flash Point 350°F 214°F Dye Fire Point 400°F 220°F Concentrate (Pensky-Martens Closed Cup) Flammability FireFighter GL and FireFighter PG are not flammable Other FireFighter Antifreeze Products since they have no measurable flash point;however,both products can flash or burn if the water content is evapo- FireFighter GL Concentrate rated off.No harmful fumes are produced. ## FireFighter PG Concentrate(New Formula) # GL and PG Custom Blends For specifications on these products please contact us. Toxicological,Environmental and Health Information *FireFighter is a Trademark of The Noble Company *BlazeMaster is a Registered Trademark of Noveon FireFighter GL and FireFighter PG are virtually harmless *'Non-Toxic is used to describe extremely low chronic and acute toxic- to animals or plants;however,the disposal of these mate- ity.No maximum safe intake for humans has been established.The product is considered GRAS by The Food and Drug Administration. rials should be in conformance with national,state and local health codes. 1 Sizes FireFighter GL and FireFighter PG are available in: 4# 1 gallon plastic bottles (6 per case, PG Ready- RECOMMENDED CONCENTRATIONS to-Use only) 4# 5 gallon pails 4# 30 gallon drums #t 55 gallon drums # 275 or 330 gallon totes FireFighter GL Ready-to-Use t-# 5000 gallon tank truck Specific Gravity Freeze Point Burst Point @ 77°F System Requirements and Limitations 1.141 -15°F -50°F All fire protection sprinkler systems that use Fire- 1.116 5°F 45°F Fighter GL and FireFighter PG should conform to 1.102 0°F -40°F local, state and NFPA requirements. The use of an- tifreeze within these systems should also conform 1.096 111°F -35°F to NFPA requirements. i i. Use of antifreeze solutions should also be in confor- mance with any state or local health codes. Please FireFighter PG Ready-to-Use contact your local health authorities if you have any questions concerning the codes in your area. Specific Gravity Freeze Point Burst Point £ @77°F € Maintenance 1.033 0°F -50°F 1.028 +10°F -20°F Chemicals which compose FireFighter GL and Fire- r Fighter PG can break down over time NFPA 25 re- 1.024 +15°F 0°F quires that the freezing point of the system should be tested at least once a year. Periodic testing of 1.020 +20°F +10°F systems is critical to maintaining the proper con- ' centration and freeze point of the fluid. Leaks, pressure surges and temperature changes to the system can cause antifreeze to flow out of the sys- s tem or water to flow into the system changing the FireFighter GL Concentrate freeze temperature. GL Concentrate Freeze Point Specific Gravity k` @60°F Testing To test the freeze protection level of FireFighter GL 40°, +5°F 1.100 or FireFighter PG the correct instrument must be used 50% -15°F 1.133 For testing FireFighter GL we have two instruments. 60% 22°F 1.151 A lab grade hydrometer or a digital refractometer. 70% -40°F 1.165 For testing FireFighter PG we have three instru- ments for test. A lab grade hydrometer, an analog i; refractometer or a digital refractometer. f' When testing indicates that the solution has weak- ened, empty the system and replace with fresh FireFighter GL or FireFighter PG, according to the installation instructions. r For further information concerning correct testing procedures and test instruments, contact our tech- nical services department and ask for"How to t Choose the Correct Antifreeze Loop Tester': € s z RECOMMENDED CONCENTRATIONS FireFighter PG Concentrate (New Formula) The Noble Company FF PG Freeze Point Specific Gravity Concentrate @ 60°F P.O. Box 350 60% -60°F 1.045 Grand Haven, MI 49417-0350 50% -26°F 1.041 www.noblecompany.com 40% -6°F 1.034 Phone: (231) 799-8000 30% +9°F 1.027 (800) 878-5788 Fax: (231) 799-8850 Fast Fax: (800) 272-1519 ACCESSORIES # Lab Grade Hydrometer Analog Refractometer Digital Refractometer 41111Mi AVAILABILITY MEMaEf FireFighter GL and Firefighter PG are tliATIONFIL available throughout the U.S. through eIlde wholesale distributors. Please contact The Noble Company for your local representa- tive and wholesaler. law TECHNICAL SUPPORT MEMBER Specifications, installation design, instal- lation techniques and unique applications will be reviewed upon request. Address inquiries ATTN: FireFighter Technical Support, Email: www.noblecompany.com or phone us at: 800-878-5788 Field services are available through fac- tory representatives and Noble Company staff. Contact The Noble Company for local representatives. Additional product information and MSDS are available immediately through our website at www.noblecompany.com or our Fast Fax service at 1-800-272-1519. These are available 24 hours a day, 7 ©2004 Form#FFPIG 1004 days a week. Supercedes 0604 1 . .. AAMTROL \.... ..../ FIRE-X-TROL® FPT Series, Fire Protection Expansion Tanks (ASME) - !175 PSIG Working Pressure SYSTEM CONNECTION B CA CHARGING In-Line Models Model Tank A B Sys. Ship No. Vol. Hel ht Diameter Conn. Wt. Lit. Gal. mm ins. mm ins. ins. kg lbs. k MODELS: FPT-5-C 15 2.1 264 1034 254 10 4'4 NPTF 9.5 21 A FPT-1 C FPT 12-C 24 6.4 397 1554 305 12 414 NPTF 15.4 36 ) 1 Stand Models n ONNECTION Model Tank A B C Sys. Ship t No. Vol. Height Diameter Dim. Conn. Wt. t ARGING Lit. Gal. mm Ins. mm ins. mm Ins. ins. kg lbs. t VE FPT-20V-C 30 8.0 495 191/2 305 12 273 10414 414 NPTF 23.6 52 FPT-30V-C 53 14.0 486 191/2 419 161/4 324 124'4 414 NPTF 44 97 MODELS: FPT-42V-C 66 17.5 616 241/4 419 1614 324 12414 414 NPTF 52.7 116 FPT-30V-C FPT-60V-C 95 25.0 838 33 419 161/4 324 12414 414 NPTF 70 154 A FPT-42V C FPT 70V-C 129 34.0 1054 411/2 419 1614 324 12414 414 NPTF 90 197 FPT-60V C FPT-80V-C 200 53.0 908 35414 610 24 406 16 11/4 NPTF 114 251 FPT-70V C FPT-120V-C 250 66.0 1111 43414 610 24 406 16 1 V4 NPTF 127.6 281 i FPT-180V-C 292 77.0 1235 481/2 610 24 406 16 1V4 NPTF 160.3 353 1 FPT 210V-C 341 90.0 1410 551/2 610 24 406 16 114 NPTF 173.4 382 -D. Constructed per ASME Code Section VIII,Division 1. 1: All dimensions and weights are approximate. s 1 Maximum Operating Conditions B i AGING Operating Temperature -20°F(-29°C)to 200°F(93°C) Working Pressure 175 PSIG(12 bar) UL , MODELS: Specifications FPT-80V-C Description Standard Construction A FPT-120V C Standard Factory Pre-charge 25 PSIG(1.7 bar) FPT-180V-C System Connection Stainless Steel FPT-210V-C Diaphragm Material High-Performance Rubber Compound Liner Material Polypropylene f ■ Shell Steel ` SYSTEM CONNECTION 5M1 V Coating FPT Red I'6'I Fluid Compatibility With or Without Antifreeze Per NFPA 13 k i Job Name Contractor Location Contractor P.O.No. Sales Representative P Model No.Ordered Engineer 1< ) I 3 Rev.03/06 Submittal data sheets can ONLY be ordered as a'Submittal Data Sheet Pack',using MCI,4400.They are not available to order on an indi- vidual basis,however each data sheet is available on the Amtrol Web Site and can be downloaded and printed for use as needed. u f I f , AJ%1TE%OIr• FIRE-X-TROL® FPT Series, Fire Protection Expansion Tanks (Non-ASME) 175 PSIG Working Pressure SYSTEM CONNECTION B CHARGING Non-ASME In-Line Models VALVE Model Tank A B Sys. Ship No. Vol. Nei ht Diameter Conn. Wt. Lit. Gal. mm ins. mm ins. Ins. kg lbs. MODELS: FPT-5 15 2.1 264 103/8 254 10 %NPTF 9.5 21 A FPT-5 FPT-12 24 6.4 397 15% 305 12 %NPTF 15.4 36 FPT 12 Non-ASME Stand Models nAL ONNECTION Model Tank A B C Sys. Ship No. Vol. Height Diameter Dim. Conn. Wt. RGING Lit. Gal. mm Ins. mm ins. mm Ins. ins. kg lbs. VE FPT-20V 3 0 8.0 495 191/2 305 12 273 10% %NPTF 23.6 52 FPT-30V 53 14.0 486 1918 419 161/4 324 12'4 4'4 NPTF 44 97 MODELS: FPT-42V 66 17.5 616 24/4 419 16/4 324 12'4 %NPTF 52.7 116 FPT-20V FPT-30V FPT-60V 95 25.0 838 33 419 16V4 324 12 '4 %NPTF 70 154 A FPT-42V FPT-70V 129 34.0 1054 411/2 419 16114 324 12'4 %NPTF 90 197 FPT-60V FPT-80V 200 53.0 908 35'4 610 24 406 16 11/4 NPTF 114 251 FPT-70V FPT-120V 250 66.0 1111 43 '4 610 24 406 16 1 V4 NPTF 127.6 281 FPT-180V 292 77.0 1235 48% 610 24 406 16 1 V4 NPTF 160.3 353 FPT-210V 341 90.0 1410 551/2 610 24 406 16 11/4 NPTF 173.4 382 All dimensions and weights are approximate. Maximum Operating Conditions B CHARGING o 0 0 ° VALVE Operating Temperature 20 F( 29 C)to 200 F(93 C) U I. -=A Working Pressure 175 PSIG(12 bar) MODELS: Specifications FPT-80V Description Standard Construction A FPT-120V Standard Factory Pre-charge 25 PSIG(1.7 bar) FPT-180V System Connection Stainless Steel FPT-210V Diaphragm Material High-Performance Rubber Compound Liner Material Polypropylene ■ Shell Steel CONNECTION 5211 W Coating FPT Red 14— 'I Fluid Compatibility With or Without Antifreeze Per NFPA 13 Job Name Contractor • Location Contractor P.O. No Sales Representative Model No.Ordered Engineer i. Rev.03/06 19 Submittal data sheets can ONLY be ordered as a"Submittal Data Sheet Pack",using MC#4400.They are not available to order on an indi- f vidual basis,however each data sheet is available on the Amtrol Web Site and can be downloaded and printed for use as needed. t • t I tqco I Fire & Building - Products rapid response HOME FIRE SPRINKLER SYSTEM € Technical Services:Tel:(800)381-9312/Fax:(800)791-5500 I t s t Figure 513D (13D) and 513D/R (13D/R) Riser Manifolds 1, 1-1/2, and 2 Inch (DN25, DN4O, and DN5O) For NFPA 13D/13R Residential Sprinkler Systems f P i General Technical f t Description Data I. i The Riser Manifolds described in this Approvals r technical data sheet provide the nec- The Figure 513D (13D) and 513D/R ...4 essary waterflow alarm, pressure (13D/R) Riser Manifolds with a cover gauge,and drain equipment in a single tamper switch for the waterflow alarm assembly for use in NFPA 13D or 13R switch are UL Listed, ULC Listed, and residential sprinkler systems as fol- FM Approved. i. lows: The Figure 513D (13D) and 513D/R NFPA 13D (13D/R) Riser Manifolds without a R • Figure 513D(13D) cover tamper switch for the waterflow 1 Inch 513D alarm switch are UL Listed and FM :; Female Thread x Female Thread Approved. NFPA 13D/13R Maximum Working Pressure z 175 psi(12,1 bar) line prior to performing the alarm test. c • Figure 513D/R(13D/R) Assembly The second option is to install an In- 1-1/2 Inch(DN40) The manifold body of the Figure 513 is spector's Test Connection down- Male Thread x Female Thread ductile iron, whereas the manifold stream of the WaterflowAlarm Switch. Male Thread x Male Thread body of the Figure 13 is cast iron.The • Figure 513D/R 13D/R two assemblies are completely inter- nent Never remove any piping cpmpo- 9 ( ) P Y Went nor correct or modify any piping ; 2 Inch(DN50) changeable in function, application, deficiencies without first depressuriz- ' Groove x Groove and end-to-end laying length. ing and draining the system. Male Thread x Groove Finish Step 1. Install the manifold body with t The variety of sizes and end connec- Red painted. the flow arrow pointing in the down- t_ tions allow cost effective and easy stream position using threaded con- , transition to check valves, control Installation nections and/or listed mechanical ` valves, and system piping. The Riser grooved connections,as applicable. Manifolds may be installed in either the The Riser Manifolds may be installed Step 2. Connect the drain line, and horizontal(flow switch on top)or verti in either the horizontal(flow switch on then close the drain valve. cal(flow going up), top) or vertical (flow going up). The Step 3. Refer to Figure 4 for wiring WARNING inlet of the Riser Manifold may be di- ' rectly connected to a shut-off control guidance. All wiring must be per- The Riser Manifolds described herein valve. formed in accordance with the Author- must be installed and maintained in ity Having Jurisdiction and/or the Na- compliance with this document, as NOTES tional Electrical Code. i well as with the applicable standards (1) Where applicable pipe thread Step 4.Place the system in service by f. of the National Fire Protection Asso- Y l- ciati a in addition to the standards of sealant is to be applied sparingly. Use filling the system with water.When fill- any other authorities having jurisdic- ofanon-hardening pipe thread sealant ing the system,partially open the con- tion. Failure to do so may impair the is recommended. trol valve to slowly fill the system. Fill- performance of these devices. (2) Provisions for an alarm test flow ing the system slowly will help avoid must be made. The alarm test flow is damaging the waterflow alarm switch. The owner is responsible for maintain- to be through an orifice having a flow After the system is fully pressurized, ing their fire protection system and de capacity equal to or smaller than the completely open the control valve. vices in proper operating condition. smallest orifice sprinkler the system. i, The installing contractor or sprinkler Step 5. Secure all supply valves One of two options can be considered. manufacturer should be contacted The first option is to temporarily install open. with any questions. a test orifice in the outlet of the drain Page 1 of 6 APRIL, 2006 TFP960 g S Page 2 of 6 TFP96O • NO. DESCRIPTION QTY. P/N ' 1 1"Manifold Body, 3-11/2" Female x Female NPT... 1 N/A (88,9 mm) I 1 2 WaterfowAlarm Switch: 1I VSR-SF modified with t Paddle,UUFM 1 971-096-01 VSR-SF modified with Paddle and Cover Tamper Switch,ULC/FM 1 976-519-01 3 Water r e s Pressure LEM Water Pressure Gauge .. 1 2343 2 3 / NOTES: 1. Approximate weight,7.5 lbs.(3,4 kg). WaterRow 1.1 2. ULC Listed Manifolds are equipped with 9314" Cover Tamper Switches installed internal to the Waterfiow Alarm Switches. (247,7 mm) ii iriffilll 3. CH:Common Hardware 3 5/8" 111111 2-7/8" ■ . 1 (73.0 mm) (92,1�mm) 3/4"NPT Drain Valve 4-1/2" (Normally Closed) (114,3 mm) 10" _ (254,0 mm) FIGURE 1 1 INCH(DN25)RISER MANIFOLD ASSEMBLY AND DIMENSIONS NO. DESCRIPTION QTY. P/N f er--1 1 1-1/2"Manifold Body, 3-1/2" Male x Female NPT 1 N/A (88,9 mm) F' li Male x Male NPT 1 N/A I _1 ) _ 2 Waterflow Alarm Switch: VSR-SF modified with Paddle,UL/FM 1 971-096-00 VSR-SF modified with Paddle and Cover Tamper , Switch,ULC/FM 1 976-519-02 3 300 psi/2000 kPa 3 2 Water Pressure Gauge .. 1 2341 NOTES: Waterfiow 111 1 1. Approximate weight,8.7 lbs.(3,9 kg). 111 *I M 2. ULC Listed Manifolds are equipped with MIIIP - Cover Tamper Switches installed internal 11-3/8" lr to the Waterflow Alarm Switches. (288,9 mm) nill 3. CH:Common Hardware . 4-1/2" 5-3/8" (114,3 mm) (136,5 mm) "� ILII 1" I II;I 1... NPT Drain Valve 2-1/8" (Normally Closed) (54,0 mm) 10"(254,0 mm) - Male x Female NPT Manifold 11-1/8"(282,6 mm) - Male x Male NPT Manifold FIGURE 2 1-1/2 INCH(DN40)RISER MANIFOLD ASSEMBLY AND DIMENSIONS I ( TFP960 Page 3 of 6 . i NO. DESCRIPTION QTY. P/N I 1 2"Manifold Body, 3-1/2" Groove x Groove 1 N/A (88,9 mm) I I MB Male NPT x Groove 1 N/A 2 Waterflow Alarm Switch: I d•-•— VSC with Paddle, UUFM 1 976-357-01 s, VSC with Paddle and f; Cover Tamper Switch, ( ULC/FM 1 976-520-01 3 300 psi/2000 kPa 3 0 2 Water Pressure Gauge .. 1 2341 Optionally Waterflow GI; Grooved or e` NOTES: 1 1111 ale NPT E 1. Approximate weight,11.0 lbs.(5,0 kg). 111 41111 Supply End MN 2. ULC Listed Manifolds are equipped with Connection Cover Tamper Switches installed internal 12" iiIii iiii to the Waterflow Alarm Switches. (304,8 mm) 3. CH:Common Hardware . I 5-7/16" N 4-1/2" ' i (138,1 mm) (114, mm) f, r 1 'I' Villa 1" ( NPT FIGURE 3, Drain Valve L 2-1/4" , i 2 INCH(DN50)RISER MANIFOLD ASSEMBLY (Normally Closed) (57,2 mm) AND DIMENSIONS 13"(330,2 mm) Groove x Groove, - g Male NPT x Groove ,; t I Care and result in operation of the associated recorded for the system when it was alarms. Consequently, notification first installed. r must be given to the owner and the fire f Maintenance department, central station, or other Alarm Test Procedure With A Test signal station to which the alarms are Orifice(See Installation Note 2) The following inspection procedure connected, and notification must be t' must be performed as indicated,in ad- given to the building occupants. Step 1. Temporarily I' dition to any specific requirements of g g P P pnrline install a test ori- y P Before closing a fire protection system face in the drain line outlet. t the NFPA, and any impairment must 9 P Y be immediately corrected. control valve for inspection or mainte- Step 2. Fully open the drain valve. nance work on the fire protection sys- Make certain that drainage water will r The owner is responsible for the in- tem that it controls,permission to shut not cause any damage or injury. their fire protection system and de- down the effected fire protection sys- Step 3.Verify operation of the associ- P Y tem must first be obtained from the ated alarms. vices in compliance with this docu- proper authorities and all personnel ment, as well as with the applicable who may be affected by this action Step 3.Close the drain valve. C standards of the National Fire Protec- must be notified. tion Association (e.g., NFPA 25), in Step 4. Remove the test orifice from addition to the standards of any After placing a fire protection system the drain line outlet. authority having jurisdiction. The in- in service,notify the proper authorities stalling contractor or product manufac- and advise those responsible formoni- Alarm Test Procedure With An turer should be contacted relative to toring proprietary and/or central sta- Inspector's Test Connection(See d any questions. Lion alarms. Installation Note 2) It is recommended that automatic Flow Test Procedure Step 1.Fully open the Inspector's Test sprinkler systems be inspected, Connection Valve. Make certain that tested, and maintained by a qualified Step 1. Fully open the drain valve. drainage water will not cause any dam- E Inspection Service in accordance with Make certain that drainage water will age or injury. local requirements and/or national not cause any damage or injury. codes. Step 2.Verify operation of the associ- Step 2. Verify that the residual (flow- ated alarms. s NOTES ing) pressure indicated by the pres- Step 3. Close the Inspector's Test No attempt is to be made to repair any sure gauge is no less that originally Connection Valve. Riser Manifold component in the field. recorded for the system when it was Only the pressure gauge or waterflow first installed. ' alarm switch can be replaced. If any Step 3.Close the drain valve. other problems are encountered the x entire riser manifold must be replaced. Step 4.Verify that the static(not flow- s ing) pressure indicated by the pres- ,, The flow and alarm test procedure will sure gauge is no less that originally €` z Page 4 of 6 TFP96O SWITCH TERMINAL CONNECTIONS UNINSULATED CLAMPING SEVERED LOOPED SECTION CAUTION: PLATE STRIPPED SINGLE An uninsulated section of a TERMINAL ENDS CONDUCTOR single conductor is not `�� SEPARATE permitted to be looped around `� CONDUCTORS CLAMPING the terminal and serve as two , PLATE separate connections.The TERMINAL wire must be severed to serve ' INCOMING `v� as twb spp providing `� of t thereby connection in the even of the connection in the event that the wire becomes dislodged from the terminal. OUTGOING IMPROPER CONNECTION METHOD PROPER CONNECTION METHOD WATERFLOW SWITCH TYPICAL ELECTRICA CONNECTIONS CONTACTS SPDT(Form C) LOCAL END OF LINE RESISTOR CONTACT RATING .... 5A @ 125 VAC SIGNAL 2.5A @ 30 VDC DEVICE NC NO 2 NC NNO• /4) NC OM COM COM CONTROL POWER PANEL NO FLOW NON-SUPERVISED STYLE B/CLASS B CONDITION CIRCUIT SUPERVISED CIRCUIT (SEE NOTE) NOTE: For supervised circuits,see"Switch Terminal Connections"above.The Waterflow Alarm Switch has two switches,one can be used to operate a central station,proprietary or remove signaling unit,while the other contact is used to operate a local audible or visual annunciator. COVER TAMPER SWITCH(ULC ASSEMBLIES ONLY) CONTACTS SPDT(Form C) CONTACT RATING .... 3A @ 250 VAC 5A @ 125 VAC 1mA©5 VDC min. NO\ • NC COM CONTACTS SHOWN WITH COVER IN PLACE FIGURE 4 WIRING GUIDANCE ( TFP960 Page 5 of 6 • Limited Ordering i Warranty Information - I Products manufactured by Tyco Fire& Riser Manifold: Building Products (TFBP) are war- Specify;Size(specify),Figure(specify l ranted solely to the original Buyer for 513D or 513D/R, (specify connection t ten(10)years against defects in mate- type inlet x outlet) Riser Manifold rial and workmanship when paid for (specify-without or with)a cover tam- x and properly installed and maintained per switch for the waterflow alarm tt under normal use and service. This switch, P/N(specify). t warranty will expire ten (10) years from date of shipment by TFBP. No NOTES warranty is given for products or com- Orders for Figure 513D or513D/R may t ponents manufactured by companies be filled with a Figure 13D or 13D/R, not affiliated by ownership with TFBP respectively. The two assemblies are #' or for products and components which completely interchangeable in func- have been subject to misuse,improper tion, application, and end-to-end lay- installation, corrosion, or which have ing length. not been installed, maintained, modi- If a ULC Listing is required, the Riser €. fled or repaired in accordance with ap- Manifold must be ordered with a cover plicable Standards of the National Fire tamper switch for the waterflow alarm Protection Association, and/or the switch. standards of any other Authorities Having Jurisdiction. Materials found t by TFBP to be defective shall be either UL/ULC/FM Assemblies I° repaired or replaced, at TFBP's sole With Cover Tamper Switch % option. TFBP neither assumes, nor 1 Inch(DN25) authorizes any person to assume for it, FT x FT P/N 4085 any other obligation in connection with 1-1/2 Inch(DN40) the sale of products or parts of prod- MT x FT P/N 4088 P P P 1-1/2 Inch(DN40) ucts.TFBP shall not be responsible for MT x MT P/N 4089 r sprinkler system design errors or inac- 2 Inch(DN50) , curate or incomplete information sup- G x G P/N 4093 plied b Bu er or Bu er's re re- 21 M (DN5o) P y y y P MT x G P/N 4094 F sentatives. In no event shall TFBP be liable, in UL/FM Assemblies s contract, tort, strict liability or under Without Cover Tamper Switch any other legal theory, for incidental, 1 Inch(DN25) k: indirect,special or consequential dam- FT x FT P/N 4047 e P q 1-1/2 Inch(DN40) ; ages, including but not limited to labor MT x FT P/N 4057 ,, charges, regardless of whether TFBP 1-1/2 Inch(DN40) F` was informed about the possibility of 2 Inch(DN 0) P/N 4058 such damages, and in no event shall G x G P/N 4059 i TFBP's liability exceed an amount 2 Inch(DN50) _' equal to the sales price. MT x G P/N 4064 The foregoing warranty is made in lieu r of any and all other warranties. ex- Replacement Parts: i press or implied. including warranties Specify:(description)for use with Fig- of merchantability and fitness fora par- ure 513D, 513D/R, 13D, or 13D/R ticular purpose. Riser Manifold, P/N (Ref. Figure 1, 2 This limited warranty sets forth the ex- or 2, as applicable). clusive remedy for claims based on failure of or defect in products,materi- als or components,whether the claim is made in contract, tort, strict liability ` or any other legal theory. t This warranty will apply to the full ex- 1 tent permitted by law.The invalidity,in F whole or part, of any portion of this warranty will not affect the remainder. F I r i I I P t 1 F: e t , Page 6 of 6 TFP960 TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19446 t tL,CD I Flow Tyco Fire Control Products I i f i it BlazeMaster i FIRE SPRINKLER PIPE & FITTINGS SUBMITTAL SHEET i 1 TYCO FIRE PRODUCTS s 451 North Cannon Avenue Lansdale,Pennsylvania 19446 www.tyco-fire.com , TECHNICAL SERVICES TEL: (800) 381-9312 • Fax (800) 791-5500 E-M !L:techserv@tycofp.com k Tex T4 '. "ter - i Li Limo 3 i. E d i } No. 19-1.5 TD915 € 4-1.1.20 a 9/2001 1 s' t Introduction Tyco Fire Products(TFP) BlazeMaster°CPVC pipe and the same time,they provide superior heat resistance and • fittings are designed exclusively for use in wet pipe strength as compared to traditional CPVC and PVC piping automatic fire sprinkler systems.They are made from a materials used in the plumbing trade.Various adapters are specially developed thermoplastic compound composed of available to connect CPVC pipe to metallic piping.All female post chlorinated polyvinyl chloride(CPVC)resin and state of pipe thread adapters have brass inserts for durability. ` the art additives.TFP BlazeMaster®CPVC products are Grooved adapters connect directly to grooved end valves easier to install than traditional steel pipe systems,and at and metallic pipe,with flexible grooved end couplings. Technical Data Sizes: 3/4"-3" Manufacture Source: U.S.A. Maximum Working Pressure: 175 psi Material: Approvals: UL, FM,CUL,NSF, Dade County, LPCB, Pipe: ASTM F442, SDR 13.5 MEA,and the City of Los Angeles Fittings: ASTM F438(Sch.40)and Note: See current TFP BlazeMaster Installation Instructions and ASTM F439(Sch.80) Technical Manual,for exact isting/appraval information Colon Orange Pipe Nom.Pipe Size Avg.O.D.Inches Avg.I.D.Inches Wt.Lbs./Ft. Wt.160 filled Pipe Lbs./Ft. Ft.of Pipe per Lift WL per Lift Lbs. 3/4" 1.050 0.874 0.17 0.43 7875 1413 1" 1.315 1.101 0.26 0.67 5040 1320 11/4" 1.660 1.394 0.42 1.07 2835 1191 1'/2" 1.900 1.598 0.55 1.40 2205 1136 2" 2.375 2.003 0.86 2.20 1260 1063 2'/2" 2.875 2.423 1.26 3.22 1215 1531 3" 3.500 2.952 1.87 4.79 ■ 720 1344 Fittings T/o_ \ T/O rm 45° Elbow _.-._._. .r Reducing -.__._._. ► + 90° Elbow 90 Elbow j T/02 ek,,, voi i , I 1 i ' i 1 Part No. Size Sch. T/O Wt. Part T/O Wt. Part No. Size Sch. T/O Wt. 80050 3/4" 40 3/8" 0.08 lb. No. Size Sch. 1 2 lb. 80025 3/4" 40 9/,6" 0.09 lb. 80051 1* 40 3/e" 0.11 lb. 80032 1"x 3/4" 40 "/,e" 73/,8" 0.16 80026 1" 40 3/4" 0.14 lb. 80052 1'/4" 40 3/4" 0.20 lb. 80027 1'/4" 40 7/8" 0.21 lb. 80053 11/2" 80 '/,e" 0.31 lb. 80028 1'/2" 80 1'h6" 0.40 lb. 80054 2" 80 3/4" 0.56 lb. 80029 2" 80 11/4" 0.79 lb. 80055 21/2" 80 3/4" 0.89 lb. 80030 2'/2" 80 1'/2" 1.14 lb. 80056 3" 80 1" 1.19 lb. 80031 3" 80 113/18" 1.82 lb. i . i R Z Tee Tf eng _-_. Cross L . :HI Cross i I Z T/O T/O (II. . T/O' • I-•-•- Tro T/O • •I-• T/O Part No. Size Sch. T/O Wt. Part T/O Wt. Part No. Size Sch. T/O Wt. 80000 3/4" 40 5/8" 0.11 lb. No. Size Sch. 1 2 lb. 80009 3/4" 40 8/18" 0.13 lb. 80001 1" 40 3/4" 0.19 lb. 80015 1"x 3/4" 40 "/,e" "/,5" 0.28 80010 1" 40 15/,8" 0.23 lb. 80002 1'/4" 40 7/8" 0.26 lb. 80011 1'/4" 40 15/,8" 0.34 lb. 80003 1'/2" 80 1" 0.51 lb. 80012 1'/2" 80 1'/,8" 0.67 lb. 80004 2" 80 13/8" 0.90 lb. 80013 2" 80 13/8' 1.00 lb. 80005 272" 80 18/,8" 1.59 lb. 80014 2'/2" 80 18/16" 1.91 lb. 80006 3" 80 1"/18" 2.41 lb. 80008 3" 80 113/,8" 2.89 lb. It -T/0 -•---T/O --I -T/O a Coupling Cap -. _ Reducer _ _ Bushing �� Part No. Size Sch. T/O Wt. Part No. Size Sch. T/O Wt. Part No. Size Sch. T/O Wt. 80200 1"x 3/4" 40 1/46" 0.04 lb. t' 80075 3/4" 40 '/e" 0.07 lb. 80100 3/4" 40 5/,e" 0.04 lb. 80201 11/4"X 3/4" 40 '/,e" 0.11 lb. 80076 1" 40 '/e" 0.11 lb. 80101 1" 40 3/6" 0.06 lb. 80202 1'/4"x 1" 40 5/16" 0.12 lb. _ 80077 1'/4" 40 3/18" 0.12 lb. 80102 1/4" 40 '/2" 0.10 lb. 80203 1/2"x 3/4" 80 5/s" 0.16 lb. I; 80078 1/2" 80 3/16" 0.25 lb. 80103 1'/2" 80 5/e" 0.20 lb. 80204 1/2"x 1" 80 '/2" 0.14 lb. 80079 2" 80 3/160 0.38 lb. 80104 2" 80 6/e" 0.31 lb. 80205 1/2"x 1'/4" 80 3/e" 0.17 lb. 80080 21/4" 80 3/,e' 0.67 lb. 80105 21/4" 80 '/e" 0.58 lb. 80206 2"x 3/4" 80 3/4" 0.27 lb. i 80081 3" 80 3/,8" 0.91 lb. 80106_ 3" 80 1" 0.88 lb. 80207 2"x 1" 80 "/1e 0.26 lb. e 80208 2"x 1'/4" 80 9/16" 0.24 lb. e T/0 80209 2"x 1'/2" 80 '/,6" 0.19 Ib. t Grooved 80215 21/4"x 1" 80 115/,6" 0.42 lb. s Coupling To.o. 80214 21/2"x 1'/4" 80 13/." 0.45 lb. Adapter ®�� I 80213 2'/2"X 1'/2" 80 11/4" 0.46 lb. E 80211 2'/2"x 2" 80 18/,6" 0.29 lb. Part No. Size Sch. T/O Wt. Pipe OD 80210 3"x 2" 80 2 3/,6" 0.72 lb. 80160 11/4"x 1'/,'Grooved 40 2 5/,e" 0.78 lb. 1'/4"(1.660") 80212 3"x 2'/2" 80 115/,6" 0.47 lb. 80161 1'/2"x 1/2"Grooved 80 2 5/,e" 0.95 lb. 1/2"(1.900") - t 80162 2"x 2"Grooved 80 2 5/,6" 1.42 lb. 2"(2.375") t 80163 2'/2"x 2'/2"Grooved 80 2 5/,e" 2.28 lb. 2'/2"(2.875") - '�� I t 80164 3"x 3"Grooved 80 21/4" 3.00 lb. 3"(3.500") Reducing - _ ' 80168 3"x 76.1mm Grooved 80 2'/," 2.72 lb. 76.1mm(3.000") Tee Elm T'° r I/O' II I/O' Tro Part T/O Wt. I. No. Size Sch•Jill 1 2 3 lb. Female ._ 80132 3/+"x 3/+"x 1" 40 3/4" 3/4" 5/e" 0.14 I Adapter ,� 80133 1"x 3/4"x 3/+" 40 1/2" 11/460 3/4" 0.14 80134 1"x 3/4"x 1" 40 5/8" 3/4" 3/4" 0.17 f" Part No. Size Sch. T/O Wt. 80260 1"x 1"x3/4" 40 3/4" 3/4" "/,e" 0.16 I' 80142 3/4"x 3/4"NPT 40 5/8" 0.41 lb. 80135 11/4"x 1"x 3/4" 40 '/,e" 3/4" '5/16" 0.21 80145 1"x 1"NPT 40 3/4" 0.63 lb. 80136 11/4"x 1"x 1" 40 "/,e" 3/4" 15/,80 0.22 80146 1'/4"x 11/4"NPT 40 '/e" 1.03 lb. 80137 11/4"x 1"x 11/40 40 73/,8" 15/,6" 13/,e" 0.26 80147 1'/2"x 1'/2"NPT 80 1" 1.42 lb. 80261 1'/4"x 1'/4"x 3/4" 40 5/8" 5/e" '/e" 0.23 t 80148 2"x 2"NPT 80 13/8" 2.66 lb. 80262 1'/4"x 1'/4"x 1" 40 3/4" 3/4" 7/8" 0.26 . 80138 1'/4"x 11/4"x 11/2 80 1" 1" 1" 0.43 t v0 80140 1/2"x 1'/4"x 3/4" 80 1/2" 5/e" 1" 0.36 80141 1'/2"x 1'/4"x 1" 80 1/4" 5/e" 1'/e" 0.38 '` Male -._._._._.--_._._. 80263 11/2"x 1'/2"x 3/4" 80 "/,e" e/,6" 1" 0.36 6. Adapter r_,.,, 80264 1'/2"x 1'/2"x 1" 80 9/,6" 9/,6" 1" 0.38 MIIMIfild 80275 1'/2"x 11/2"x 1'/4" 80 '/e" '/e" 1" 0.45 Part No. Size Sch. T/O Wt. 80265 2"x 2"x 3/." 80 3/4" 3/4" 13/6" 0.61 80157 3/4"x 3/4"NPT 40 15/,8" 0.33 lb. 80266 2"x 2"x 1" 80 '/e" '/6" 13/e" 0.66 80158 1"x 1"NPT 40 13/e" 0.56 Ib. 80274 2"x 2"x 11/4" 80 1" 1" 13/8" 0.74 80267 2"x 2"x 1/2" 80 1'18" 1'/8" 13/6" 0.78 -- -T/0 80271 21/4"x 2'/2"x 1" 80 1"/,6" 1"/,600 15/,e" 1.43 80272 2'/2"x 2'/2"X 1'/4" 80 1"/,." 1"/,e" 19/,8" 1.46 Reducing lit_ 80273 2'/2"x 2'/2"x 1'/� 80 1"/,e" 1"/18" 19/,8" 1.48 Coupling 80276 2'/2"X 2'/2"x 2" 80 1"/16" 1"/16" 19/18" 1.50 80270 3"x 3"x 1/2" 80 13/4" 13/4" 113/15" 2.28 Part No. Size Sch. T/O Wt. 80268 3"x 3"x 2" 80 13/4" 13/4" 13/4" 2.25 I 80220 1"x 3/4" 40 '/8" 0.08 lb. 80269 3"x 3"x 272" 80 13/4" 13/4" 115/,6" 2.44 t t t r t i --T/O —Tro Sprinkler Head Adapter _ �- ,_ Sprinkler Head Adapter illija _ • with Brass Threaded Insert ...� with Brass Threaded Insert Part No. Size Sch. T/O Wt. Part No. Size Sch. I/O Wt. * 80175E 3/4"x'12"NPT 80 7/1e 0.20 lb. 80175W 3/4"x'/z NPT 40 '/,e 0.19 lb. 80176E 1"x'/2 NPT 80 1/46" 0.22 lb. 80176W 1"x'/2"NPT 40 7/,6" 0.18 lb. 80177WL 3/4"x'/2"NPT 40 9/16" 0.16 lb. 80179 1 x 3/."NPT 40 3/s" 0.43 lb. i i T/O' Tro Back-to-Back Cross .. Sprinkler Head Adapter ;,, with Brass Threaded Insert $ a l � (Spigot) _._�, — T/°' i I I with Brass Threaded Insert i Tro' I Tro' Part No. _ Size Sch. T/O Wt. Part T/O Wt. 80177L 3/4"x'/2"NPT 40 1/2" 0.16 lb. No. Size Sch. 1 2 lb. 80178 1"x'/2"NPT 40 1/2" 0.20 lb. 80462 1"x 1"x'12"NPT x V2"NPT 40 5/e" 11/8" 0.46 80463 1"x 1"x'/2"NPT x NPT 40 5/e" 16/+e" 0.47 TAY Sprinkler Head Adapter 1 90° Elbow - lip Tro= rro'_ � �� , with Brass Threaded Insert uc + Back-to-Back Tee Mi Q 1111 with Brass Threaded Insert 1 ' �^ i T/°' Tro' Part T/O Wt. Part Size Sch. T/O Wt. No. Size Sch. 1 2 lb. No. 1 2 lb. - 80199 3/4"x'/z"NPT 40 5/e' 15/+e' 0.20 80459 1"x'/2"NPT x'/2"NPT 40 "/+e" 15/,6" 0.48 80189 1"x'/2"NPT 40 13/,e 13/,e" 0.26 80460 1"x1/2"NPT X1/2"NPT 40 "/16" 1'/e 0.46 Part Size Sch. 1 T/O 3 lb.Wt. 80250 3/4"x 3/4"x'/2"NPT 40 5/e" 5/e" 1" 0.22 I 80251 1"x 1"x'/2"NPT 40 "/,e" "/+e" 13/16" 0.29 111! I 80249 1"x 1"x 1"NPT 40 75/,e" 15/1e 1'/16" 0.73 Sprinkler Head Adapter v rid 80256 1'/ x 1"x'/2"NPT 40 '/1B 9/+e 1'/e" 0.30 Tee + 80252 1'/4"x 1'/4"x'/2"NPT 40 7/,6" '/,e" 1'/e" 0.31 with Brass Threaded Insert - 80257 1/2"x 1'/4"x'/2"NPT 80 9/,6" 54" 17/,6" 0.43 T/O' 1 ._Troy 80254 11/2"x 1'/2"x'/2"NPT 80 9/+6" 9/+6" 1'/16" 0.46 80258 2"x 11/2"x1/2"NPT 80 1/2" 5/e" 15/e" 0.56 80253 2"x 2"x'/2"NPT 80 1/2" '/2" 15/e" 0.62 Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten(10)years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten(10)years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse,improper installation,corrosion,or which have not been installed,maintained,modified or repaired in accordance with applicable Standards of the National Fire Protection Association(NFPA),and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced,at Tyco Fire Products sole option. Tyco Fire Products neither assumes,nor authorizes any person to assume for it,any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE,IN CONTRACT,TORT,STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY,FOR INCIDENTAL,INDIRECT,SPECIAL OR CONSEQUENTIAL DAMAGES,INCLUDING BUT NOT LIMITED TO LABOR CHARGES,REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCT'S LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED,INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, tgCO/Flow Control/p oducts ® TOLCO www.tolco,com :, rr,d o,NIBCQ Revision 5/24/2001 i t Fig. 24 - Hanger for CPVC Plastic Pipe Double Fastener Strap Type - Side Mount iC 1 t t. Size Range— 3/4"thru 2"CPVC pipe C Material—Carbon Steel, Pre-Galvanized , -'� „ Function—Intended to perform as a hanger/restrainer to support only / �' CPVC piping used in automatic fire sprinkler systems. Can be installed r on the top or on the bottom of a beam. The Fig.24 can also function i as a restrainer to prevent the upward movement of the sprinkler head I / during activation. ,,� Approvals—Underwriters'Laboratories Listed in the USA(UL) and `, 1 � Canada (cUL)to support fire sprinkler piping. Meets and exceeds the 1 requirements of NFPA 13, 13R and 13D. , l' Features—Fig.24 incorporates features which protect the pipe and t ease installation. The flared edge design* protects the CPVC pipe from i any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws**furnished with the product. It 10 1 is recommended that rechargeable electric drills fitted with a hex socket 5 attachment be used as installation tools. No impact tools (such as a hammer) B or impact fasteners(such as drive screws or nails)are allowed. Damage has t been known to result from installations using impact type tools. No pre-drilling z tt of a pilot hole in wood is required. B A ' Finish—Pre-Galvanized It Order By—Figure number and pipe size * Patent Pending I 1 **Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. i, t F t Dimensions •Weights CPVC Max.Hanger Fastener Hex Approx. Pipe Size A B C Spacing(Ft.) Head Size Wt./100 1 3/4 2'/„ 15/32 134„ 512 5/16 9 1 254 15/,e 15/,a 6 5/16 9 s: 11/4 3 11/2 13/m 6'/2 5/16 11 , 11/2 3'/. 15/B 1'/,e 7 5/16 12 t` 2 3"4e 127/32 13/,e 8 5/16 15 i' t i I 1 1 i III Main Office/Manufacturing Facility•1375 Sampson Ave.•Corona,CA 92879•Ph: 909.737.5599•Fax 909.737.0330 Customer Service•800 786 5266 €; w 1 www.tolco.com 4 I . ® 1 DLCD www,tolco,com , NIECO Revision 5/24;2001 Fig. 24 - Hanger for CPVC Plastic Pipe Double Fastener Strap Type - Side Mount SCI Size Range— 3/4"thru 2" CPVC pipe C Material—Carbon Steel, Pre-Galvanized .„.. Function—Intended to perform as a hanger/restrainer to support only ;' CPVC piping used in automatic fire sprinkler systems. Can be installed i on the top or on the bottom of a beam. The Fig.24 can also function as a restrainer to prevent the upward movement of the sprinkler head ! t, during activation. ,„., 1 Approvals—Underwriters'Laboratories Listed in the USA(UL) and •,...,� ' Canada (cUL)to support fire sprinkler piping. Meets and exceeds the ` requirements of NFPA 13, 13R and 13D. Features—Fig.24 incorporates features which protect the pipe and ease installation. The flared edge design* protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws**furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) B/ or impact fasteners(such as drive screws or nails)are allowed. Damage has .�-'-- been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. B A Finish—Pre-Galvanized Order By—Figure number and pipe size * Patent Pending **Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Dimensions •Weights CPVC Max.Hanger Fastener Hex Approx. Pipe Size A B C Spacing(Ft.) Head Size Wt./100 3/4 25/,3 15/32 13/,5 51/2 5/16 9 1 25/5 15/,5 1'/,5 6 5/16 9 1'14 3 1'/2 1'/,a 61/2 5/16 11 1'/2 31/1 15/5 1'/,e 7 5/16 12 2 3"/,5 127/32 13/,e 8 5/16 15 ® Main Office/Manufacturing Facility•1375 Sampson Ave.•Corona,CA 92879•Ph: 909.737.5599•Fax: 909.737.0330 Customer Service•800.786.5266 www.to(co,com ® TOLCD www.toico.com .a NIBCO• Revision 4,27/2006 Fig. 28 c0 US LISTED "Stand-Off" Hanger & Restrainer for CPVC Plastic Pipe I Size Range—'/a"through 2" - Material—Carbon Steel, Pre-Galvanized • Function—Designed to be used as a hanger and restrainer for CPVC piping where the "stand-off'design will ease installation by eliminating the need for wood blocking. ` I Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces. A I: • Unique twist and lock design holds pipe firmly in place and allows retrofit type B of installation. • The "Stand-Off"design eliminates the need for wood block extension. • Can be installed on horizontal or vertical piping regardless of mounting / I surface orientation. • Attaches easily to wood structure with two hex head self-threading screws i furnished with product. i • Installs easily using rechargeable electrical driver with 5/16"extension socket { eliminating impact tool damage to pipe. is • Attaches easily to steel, minimum 18 gauge with (2) 1/4"x 1"tek type self drilling tapping screws. • U.L.Listed as a hanger and a restrainer for fire sprinkler piping. Approvals—Underwriters' Laboratory Listed in the USA(UL) and Canada (cUL)to s support automatic fire sprinkler systems. May be installed into wood using fasteners supplied with product, or into minimum 18 gauge steel using (2) 1/4"x 1"tek type screws. f'" Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig.28 satisfies the UL vertical restraint requirement where needed. UL Listed as a hanger and vertical restraint t I when installed on 3/8" composite wood material. Use two Fig.27B Speed Nuts when 7 I used as a hanger and restraint. Use one Fig.27B Speed Nut on the upper installed t 1 0. ' screw when used as a hanger only. 1 Order by—Figure number and pipe size. F' US AND INTERNATIONAL PATENT APPLICATION IN PROCESS. {` `'':\, t vb re h �u� Cm-' s f+lcurtm.... \ 1,04 274 1 k , WON SIDE aD. r23 REWIRED 111 \ >: s' / .' ■ / t. Dimensions •Weights HANGER HER AFVUCATIQN &RESTRAENT Pipe Approx. ...a APPLICATION Size A B C Wt. g T: t 3/4 31/22 2 311 .180 �.. __..._. ._._ r" 1 3916 2 6 37h 210 i 11/4 3% 2 31/2 225 • I { -. .. T 17h 4 21/2 31i'z 310 F��........._.._ i -" Wl t! .. 2 41/2 2116 3% .340 —� — 1 F4 30 t, i a / f 3 3: OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH: 951 737 5599•FAX 951.737.0330 F 38 CUSTOMER SERVICE•800 786 5266 s www.tolco.com t ® TOLCO www.tolco,corn ,::i "fNIBCO Revision 5/24/2001 a 7. Fig. 22C - Combination Hanger & Restrainer Application s® Size Range— 3/4"thru 2"CPVC pipe -` N'b Material—Carbon Steel, Pre-Galvanized Function—Designed to support a CPVC pipe away " ,,R�'-'- , from the corner of a beam. This position allows for easy ,- 'k\ installation of drops or risers without adding additional ` �' .,,, ° f 8" wood blocks. Approvals—Underwriters'Laboratories Listed in the USA --' t r (UL)and Canada (cUL)for use as a combination hanger and ,- �` ,-A--- TRUSS HEADER restrainer. ,,--' / OR Finish—Pre-Galvanized ~r TRUSS JOIST Note—Approved UL Listed fastener into wood is furnished } % _'--` (TYR) with the product. A fastener into light gauge metal may be ordered separately. Minimum acceptable#10 x 1"hardened �J•' ,- " . self threading screw with 5/16"hex washer head. " ,.�i '` - Order By-Fig.22C application is composed of two -�, �"\ . ,,..` "� >% 1 5!8" standard Fig.22 models—order two singles for each hanger ,„:` - - .° ),and restrainer application required. ( '\ .- '— f r 4110 i liW '''':,,---:-.::'!'-::: r ° °'- 151$° 'ii ' x'..."` ma,,: 1 7<p P ',.,,,,,,,, ...,` ,`‘'<\:,,,'{\ ,,,,,,,.."` k - .ii. ;0111,1himiii, 11......_ 1 ,...,...„.....\\:,,......„..„--,,,,,,__...„: t4 Is' irio Main Office/Manufacturing Facility•1375 Sampson Ave.•Corona,CA 92879•Ph: 909 737 5599•Fax 909.737.0330 Customer Service•800 786 5266 www.tolco.com x NIBCOw,'. h ��C =.m 250 lb WWP Bronze Ring Check® Valves Dezincification Fire Protection Valve •Inline Lift Type • Rubber Discs • Spring Actuated Resistant 250 PSI/17.2 Bar Non-Shock Cold Working Pressure' 1 I I t CONFORMS TO MSS SP-80 } MATERIAL LIST PART SPECIFICATION 1 1. Body Bronze ASTM B 584 Alloy C84400 s; 2. Stem Stainless Steel ASTM A 582 I Alloy C30300 T-480 , 3. Spring 316 Stainless Steel Threaded 4. Disc Holder Stainless Steel Type 301 5. Disc Water,Oil or Gas(Buna-N) 6. Seat Screw Stainless Steel ASTM A 276 t Alloy S43000 7. Body End Bronze ASTM B 584 Alloy C84400 4 ) 4 F'1• f tr: A 0 \ As a DIMENSIONS-WEIGHTS-QUANTITIES Q `` : -- t. Dimensions -^® • = ,-.."'�, Size A B C T-480 Master 'd In. mm.In. mm. In. mm. In. mm. In. mm. In. Ctn.Qty. 9's 10 2.00 51 1.38 35 1.44 37 0.41 0.19 100 r 1h 15 2.06 52 1.38 35 1.19 30 0.36 0.16 100 NPTTxNPT 3/4 20 2.25 57 1.63 41 1.31 33 0.48 0.22 100 1 25 2.63 67 2.00 51 1.50 38 0.77 0.35 50 11/4 32 2.94 75 2.38 60 1.69 43 1.14 0.51 30 1 11h 40 3.31 84 2.75 70 2.00 51 1.63 0.74 30 2 50 3.69 94 3.38 86 2.31 59 2.27 1.03 10 Ordering:The T-480 has standard Buna-N Discs. Also available with TFE(Y)Discs;specify T-400-Y. NIBCO check valves may be installed in both horizontal and vertical 46`thru 2`require IA pound pressure to open. lines with upward flow or in any intermediate position. WARNING-Valve must be installed downstream of receiver tank if t used in line with reciprocating air compressor. Do Not Use as a Footvalve. Warning-Do Not Use For Reciprocating Air Compressor Service. E NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 II i TECH SERVICES PH:1.888.446.4226•FAX 1.800.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3221•FAX:+1.574.295.3455 www.nibco.com I VSR-F • P POTTER VANE TYPE WATERFLOW ® The Symbol of Protection ALARM SWITCH WITH RETARD UL,ULCandCSFMListed,FMandLPCBApproved,NYMEA Accepted,CE Marked Service Pressure: Up to 450 PSI(31 BAR) Minimum Flow Rate forAlarm:10 GPM(38 LPM) Maximum Surge: 18 FPS(5,5 m/s) ContactRatings: Two sets of SPDT(Form C) y 15.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive Conduit Entrances: Two knockouts provided for 1/2"conduit Environmental Specifications: ' • Suitable for indoor or outdoor use with factory installed gasket and die-cast housing. • NEMA 4/IP54 Rated Enclosure-use with appropriate - -• wt� ':, ` conduit fitting. � • Temperature Range: 40°F/120°F, 4,5°C/49°C • Non-corrosive sleeve factory installed in saddle. Caution:This device is not intended for applications in explosive environments. Sizes Available: Steel Pipe schedules 10 thru 40,sizes 2"thru 8" BS 1387 pipe 50mm thru 200mm Note: For copper or plastic pipe use Model VSR-CF. "'`'t Service Use: Automatic Sprinkler NFPA-13 U.S. Pat. No.3921989 One or two family dwelling NFPA-13D Canadian Pat. No. 1009680 Residential occupancy up to four stories NFPA-13R Other Patents Pending National Fire Alarm Code NFPA-72 Potter Electric, Rd., 1990 Optional: Cover Tamper Switch Kit,Stock No.0090018 GENERAL INFORMATION INSTALLATION: See Fig.2 The Model VSR-F is a vane type waterflow switch for use on These devices may be mounted on horizontal or vertical pipe. wet sprinkler systems. It is UL Listed and FM Approved for On horizontal pipe they should be installed on the top side of the use on steel pipe; schedules 10 through 40, sizes 2" thru 8" pipe where they will be accessible. The units should not be in- (50mm thru 200mm). stalled within 6"(15cm)of a fitting which changes the direction of LPC approved sizes are 2" thru 8" (50mm thru 200mm). the waterflow or within 24"(60 cm)of a valve or drain. The unit may also be used as a sectional waterflow detector Drain the system and drill a hole in the pipe using a circular saw on large systems. in a slow speed drill.The 2"(50mm)and 2 1/2"(65mm)devices require a hole with a diameter of 1 1/4" + 1/8" - 1/16" (33mm The unit contains two single pole, double throw, snap action ±2mrm).All other sizes require a hole with a diameter of 2"±1/8" switches and an adjustable, instantly recycling pneumatic re- tard. The switches are actuated when a flow of 10 gallons per minute (38 LPM) or more occurs downstream of the device. Clean the inside pipe of all growth or other material for a dis- The flow condition must exist for a period of time necessary to tance equal to the pipe diameter on either side of the hole. overcome the selected retard period. Roll the vane so that it may be inserted into the hole;do not bend ENCLOSURE: The unit is enclosed in a general purpose, die- or crease it. Insert the vane so that the arrow on the saddle cast housing.The cover is held in place with two tamper resis- points in the direction of the waterflow. Install the saddle strap tant screws which require a special key for removal. A field in- and tighten nuts alternately to an eventual 50 ft-lbs. (68 n-m)of stallable cover tamper switch is available as an option which torque(see Fig.2).The vane must not rub the inside of the pipe may be used to indicate unauthorized removal of the cover.See or bind in any way. bulletin no. 5400775 for installation instructions of this switch. Specifications subject to change without notice. Potter Electric Signal Company•2081 Craig Road,St.Louis,MO,63146-4161•Phone:800-325-3936/Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8800001-REV W PAGE 1 OF 2 MFG.#5400761-7/02 , , . , , : 1,i P POTTER vsR-F VANE TYPE WATERFLOW . . The Symbol of Protection ALARM SWITCH WITH RETARD , I FIG. 1 FIG.2 4 i SWITCH TERMINAL i i CONNECTIONS OPTIONAL TAMPER SWITCH DO NOT LEAVE COVER OFF FOR EXTENDED PERIOD OF TIME CLAMPING PLATE 1 k TERMINAL RETARD ADJUSTMENT: 41 •'/14!& TO CHANGE TIME TURN KNOB (EITHER DIRECTION) i ;%,.,,,,irl.,,,boor. TIGHTEN NUTS 1 FOR DESIRED TIME DELAY. USE THE MINIMUM p ALTERNATELY TO AN 1 AMOUNT OF RETARD NECESSARY TO PREVENT .Alt."I 15kkb..10- EVENTUAL SOFT-LOS (68 n-m) FALSE ALARMS. A " " SETTING IS UUALLY l' '' OF TORQUE 1 I f,1,. 1\ f'it4C" ADEQUATE FOR THIS B RY IS FACTO SET S TO "B" Ill•. CO i TO INSTALL. DRILL HOLE AS INDICATED: i I C;) 11110 I W PIPE SIZE HOLE SIZE ‘Ili 111., jk\ CO 1 01/T°16 Om.1923-3 2" to 2 1/2" 1 1/4" +1/8 -1/16" Iv. 7_i_ 1111111 DI W, toglW MOUNT ON PIPE SO ARROW ON SADDLE (50mm to 65mm) (33mm ±2mm) IN POINTS RECTION / CAUTION: 3" to 8" 2' ±1/8" ------, lirlivilik OF WATERFLOW i An uninsulated section of a (somm to 200mm) 50mm ±2rnm) ROLL PADDLE IN single conductor should not po kw OPPOSITE DIRECTION Tamper ! be looped around the termi- --=--, (wiCover th cover in place) OF WATERFLOW ;- nal and serve as two sepa- rate connections. The wire 1 fi DIRECTION OF must be severed, thereby WATERFLOW, I 0 0 1 , t providing supervision of the c NO NC APPROX. RETARD SETTINGS (IN SECS.) I Ow) (Ra8 WO connection in the event that 0 ABC OE i i 1 the wire becomes dislodged OM 011.141144 DWG #761-30 0 10-25 20-40 35-55 30-70 60-90 1 g ' i from under the terminal. i I , I 1 } 1 FIG.3 TYPICAL ELECTRICAL CONNECTIONS NOTES: FIG.4 ' , 1 1. The Model VSR-F has two To remove knockouts: Place i i , switches,one can be used to screwdriver at edge of knock- 1 i 3 SEM OF NORMALLY CPEN CCRTACTS w,,,,,,,,,,zo., ECOV FNON CLOSE ON ALARM ON ME PAM. rPE"1°- operate a central station,pro- prietary or remote signaling outs, not in the center. i I i 11111111M1111 alL■MLII unit,while the other contact is I c.1 FT, i 1 i ,g kill L:11 used to operate a local audible cd1111711 No wil us in iim me or visual annunciator. ' , .rir 1..r 1 i , , Ir. 1. ,, 1:,-,: 1 , :,-,,, 2. A condition of LPC Approval of F = mo Imi NE mg NE this product is that the electri- 1 / / THE NC MID 1•3 WRIONGS POSITP/E OC OM THE 9MTC14 ARE FOR OR HOr AC CD cal entry must be sealed to I NI ALARM CORWIN. : THE CCRTACTS PECATNE OC ME REVERSE° oR p&-uTRAL,e exclude moisture. PIHOV THE DEVCE IS IN ORO./73,2 , THE ION./CONDITION. 111 0 Q 0 1'141I 1 I 3. For supervised circuits see I I "Switch Terminal Connec- tions" drawing and caution OWC.1761-4 I ,I i note(Fig.1). , i )' APPLICATION WARNING! I , Due to the possibility of unintended discharges caused by pressure surges,trapped air, or short retard times,waterflow switches I oi that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF,deluge, or [ I chemical suppression systems. i i i TESTING z The frequency of inspection and testing for the model VSR-F and its associated protective monitoring system should be in 1 t 1 accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction(manufacturer recommends i 1 1 quarterly or more frequently). 3 3 If provided,the inspector's test valve,that is usually located at the end of the most remote branch line,should always be used for 1 i test purposes. If there are no provisions for testing the operation of the flow detection device on the system,application of the VSR-F is not recommended or advisable. i t 4 A minimum flow of 10 gpm(38 Lpm)is required to activate this device. i 1 1 ' IMPORTANT NOTICE: Please advise the person responsible for testing of the fire protection system that this system must be 1 tested in accordance with the testing instructions. ; 1 , 1 I PRINTED IN USA MKT.#8800001-REV W PAGE 2 OF 2 MFG.#5400761-7/02 I i I i . i I ' i s . P WHEELOCK PDTTEJ . SERIES MT AND MT STROBE ® The Symbol of Protection MULTITONE ELECTRONIC SIGNALS Wheelock's MT and MT Strobe Series Multitone Electronic Signals offer a choice of eight(8)nationally and internationally recognized alerting sounds: Horn,Bell,March Time Horn,Code-3 Tone,Code-3 Horn,Slow Whoop,Siren or Hi/Lo Tone. Wheelock's Code-3 horn and tone patterns are engineered to comply with NFPA/ANSI Temporal Pattern specifications without requiring additional coding means. With MT and MT Strobe Signals, one alarm appliance meets most of your signaling needs.Wheelock's MT and MT Strobe Signals are UL Listed, FM, CSFM and NYMEA Approved. Features • One alarm appliance with (8)eight selective signals to provide superior sound penetration for various ambient \ and wall conditions with two field selectable sound output i levels. • Code-3 Horn and Tone meet NFPA/ANSI/ISO temporal t pattern for standard emergency evacuation signaling. , • Audible and strobe can operate from a single signaling circuit. t ; . • Designed to meet or exceed NFPA/ANSI Standards and ADA Accessibility Guidelines. 110 VAC model does not meet ADA requirements. ' • Low current draw with low temperature compensation to reduce power consumption and wiring costs. • Low cost installation via standard electrical boxes. Attractive flush or surface mounting options available. MT-24-1575W-FR SHOWN MT-121575W-FR MT 12/24 MT-24-1575W-FR* MT4-115-WH-VFR (Strobe/Horn) (Horn) (Strobe/Horn) Indoor (Strobe/Horn) Model Stock No. 1610921 Stock No. 1610914 Stock No. 1610915 Stock No. 1610216 Mounting Options** Mounting Options** Mounting Options** Mounting Options** D,E,F,L,M,O,P,R D,E,F,L,M,O,P,R D,E,F,L,M,O,P,R D,E,J,K,N,O,R dBA and Current Ratings Average Current Ratings(Amps) dBA Reverberant Ratings dBA Anechoic Ratings Per UL 464 Tone @ 24VDC ©12VDC @ 24VDC ©12VDC @ 12 and 24VDC HI STD HI STD HI STD HI STD HI STD Horn 0.038 0.024 0.095 0.019 92 87 90 77 99 93 Bell 0.019 0.012 0.030 0.010 86 80 85 69 92 87 March Time Horn 0.038 0.024 0.095 0.019 89 84 89 74 99 93 Code-3 Horn 0.038 0.024 0.095 0.019 88 83 88 73 99 93 Code-3 Tone 0.027 0.016 0.057 0.014 85 80 84 70 95 90 Slow Whoop 0.047 0.025 0.095 0.024 90 89 89 75 99 94 Siren 0.034 0.022 0.078 0.019 89 84 89 75 98 93 Hi/Lo 0.020 0.013 0.042 0.011 86 81 86 71 93 88 • For outdoor installation use MTWP-2475W-FR with IOB-R backbox. ** See next page for mounting options. Potter Electric Signal Company•2081 Craig Road,St.Louis,MO,63146-4161•Phone:800-325-3936/Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8850002-REV H PAGE 1 OF 2 2/03 . It ! : WHEELOCK PQ SERIES MT AND MT STROBE e The Symbol of Protection MULTITONE ELECTRONIC SIGNALS #_ i MOUNTING ACCESSORIES 4 f r (D)4"SQUARE,FLUSH(BO) (E)4"SQUARE,DEEP,FLUSH(BO) (F)DOUBLE-GANG,FLUSH(BO) ��oo NI 0 a , c 0., PJI!Io ;Rip r MAXIMUM NUMBER OF CONDUCTORS MAXIMUM NUMBER OF CONDUCTORS MAXIMUM NUMBER OF CONDUCTORS x AWO.HS AWO.HS AWO.314 AWE,.312 AM.318 AWO.HS AWO.1H4 AWO.H2 AWO.HS AWO.HS AWO.H4 AW0.1112 4 4 4 4 8 S 8 • 4 4 4 4 l (J)BB BACKBOX (K)WBB WEATHER RESISTANT BACKBOX (L)ISP SURFACE ADAPTER (Order Code:2830) (Order Code:2959) (Order Code:5306) Standard steel backbox with knockouts for Sturdy die-cast housing,threaded conduit hole Indoor use. K interior surface mounting,concealed conduit and knockout for outdoor applications.It is mounting or semi-flush applications. It is painted to match the signal painted to match the signal. �. @. ,y. rN I{—f 1M y, r'--___7 4O O .� s i 1 i i $t �� .M k i + . .-N lE/S} 1 1 r w.or f: 11.4r:THH"-..'" ki,ea.4 AM—I t Rai, p t MAXIMUM NUMBER OF CONDUCTORS MAXIMUM NUMBER OF CONDUCTORS MAXIMUM NUMBER OF CONDUCTORS AWO.HS AWO.HS AWO.314 AWO.012 AWO.HS AWO.HS AWO.H4 AM.012 AWO.HS AWO.HS AWO.314 AWO.1012 4 4 4 4 4 4 4 4 a 8 8 • z (0)RP-R RETROFIT PLATE (R)SFP SEMI-FLUSH PLATE (M)10B BACKBOX (Order Code:5042) (Order Code:2957) (Order Code:5046) Stamped aluminum surface wall plate which For surface mounting MT products. t. mounts behind the basic unit and serves to cover recessed backboxes in semi-flush r.....--1 mounting applications.It is painted to match nA. �w the signal. r. i I .SYY.M K 5. f11 EE • 1 LIII1 � I 0m0 Oar. ♦e e+ f MAXIMUM NUMBER OF CONDUCTORS t OMG.�8a50002-1 AWE,.HI AWO.in *WO.0.14 AWO.H2 8 S 8 4 i F MOUNTING NOTES t CAUTION:The mounting options figures show the maximum number of field wires(conductors)that can enter the backbox used with each mounting option.If these limits are exceeded,there may be insufficient space in the backbox to accommodate the field wires and stresses from the wires could damage the product. f ffi Although the limits shown for each mounting option comply with the National Electrical code(NEC),Wheelock recommends use of the largest backbox option and the use of approved stranded field wires whenever possible,to provide additional wiring room for easy installation and minimum stress on the product from wiring. CAUTION:Check that the installed product will have sufficient clearance and wiring room priorto installing backboxes and conduit,especially if sheathed multiconductor cable or 3/4"conduit fittings are used. y 1. Mounting hardware for each mounting option is supplied. i 2. Conduit entrances to the backbox should be selected to provide sufficient wiring clearance for the installed product.When extension rings are required,conduit should enter through the backbox,not the extension ring.Use Steel City#53151(1-1/2"deep)or 853171(2-1/8"deep)extension rings(as noted in the mounting options)or equivalent f; with the same cut-out area. 3 3. When terminating field wires,do not use more lead length than required.Excess lead length could result in insufficient wiring space for the appliance. t 4. Use care and proper techniques to position the field wires in the backbox so that they use minimum space and produce minimum stress on the product.This is especially important for stiff,heavy gauge wires and wires with thick insulation or sheathing. 5. Do not pass additional wires(used for other than the appliance)through the backbox.Such additional wires could result in insufficient wiring space for the appliance. t ( t PRINTED IN USA MKT.#8850002-REV H PAGE 2 OF 2 ft 2/03 ( i 1;. r cgg ) NIBCO • 400 lb. WWP Bronze Ball Valves Fire Protection Valve • Standard Port • Two-Piece Body • Blowout-Proof Stem • TFE Seats 400 PSI/27.6 Bar Non-Shock Cold Water MATERIAL LIST PART SPECIFICATION T-580 1. Handle Nut Zinc Plated Steel Threaded 2. Handle Zinc Plated Steel Clear Chromate Plastisol Coated 3. Packing Gland Brass ASTM B 16 Alloy C36000 4. Packing TFE 5. Stem Silicon Bronze ASTM B 371 Alloy C69400 C or ASTM B 16 Alloy C36000 O 6. Ball Brass ASTM B 16 Alloy C36000 or ASTM B 124 Alloy C37700 7. Seat Rings TFE \% 11� 8. Body Bronze ASTM B 584 Alloy C84400 Q © e p or Brass ASTM B 124 Alloy C37700 1INC !a o 9. Bod y End piece Bronze ASTM B 584 Alloy C84400 IM- nl a' or Brass ASTM B 124 Alloy C37700 WPM '4% D A T-580 NPT x NPT DIMENSIONS-WEIGHTS-QUANTITIES Dimensions Size A B C D Port Weight Box Master In. mm. In. mm. In. mm. In. mm. In. mm. Lbs. Kg. Qty. Ctn.Qty. ih 15 2.00 51 1.56 40 3.94 100 .38 8 .57 .26 10 60 3/4 20 2.28 58 1.72 44 3.94 100 .50 13 .72 .33 10 60 1 25 2.88 73 2.06 52 4.69 119 .75 19 1.25 .57 5 30 11/4 32 3.41 87 2.31 59 4.69 119 1.00 25 1.65 .79 4 40 1 lh 40 3.75 95 2.81 61 6.75 171 1.25 32 2.53 1.19 2 10 2 50 4.44 113 3.13 79 6.75 171 1.50 38 3.65 1.66 1 10 NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX:1.800 234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3221•FAX:+1.574.295.3455 www.nibco.com t CENTRAL Sign 1 -95 Signs „ , , „,,,... ,,,„..,_L. • i al: {,EI rIr '� R 11111. 1. Forsprinkler systems & devices 1 IIIIIIIIIIIIIMIIIII Manufactured by:Central Sprinkler Company 451 North Cannon Avenue,Lansdale,Pennsylvania 19446 Main drain i i Product Open sprinkler control Open sprinkler drain Identification Description TTest valve angular main drain Water motor Signs s t Central's Identification Signs are Water motor line designed to provide information to the end user about the sprinkler system and it's components.They are Technical available with a variety of wording Data 1 combinations to meet the signing ii requirements of NFPA 13. The five basic types of signs are as Model: Sign follows: Style: Flat, rectangular a Type A-Control Valve Sign Standard Finish: porcelain or mylar Type B-Multi-purpose Text Signs Size: Type A-9”x 7" Type C-Cold Weather Sign Type B-6"x 2" Type D-Fire Alarm Sign Type C-7%"x 11/4" Type E-Hydraulic Calculation Sign Type D-9"x 7" The Signs are constructed of 18 Type E-5"x 7" gauge steel or aluminum with a Weight: Type A-4.5 oz. porcelain enamel or printed mylar Type B-0.5 oz. facing respectively.The signs have Type C-2.0 oz. corner holes or slots for easy attach- Type D-4.0 oz. ment in the field. Type E-1.5 oz. Sign Type B is available with the following text options: Air control Installation Air control valve 0 Air line Alarm test Alarm line Antifreeze system The Identification Signs are pro- Auxiliary drain vided with %8"diameter or larger holes Control (or slots)in the corners for easy Control valve attachment using standard hardware Drain chain,wire, plastic lock ties,or light Drain valve gauge metal strap(not included). Entire system From city main In this building In this section Inspectors test Main control No.28-9.0 • " Sign -Type A Sign-Type D THIS VALVE CONTROLS • • Ordering SUPPLY AUTOMATIC SPRINKLERS SPRINKLER To • FIRE - ALARM rill Information v • • When placing an order, indicate MUST OPEN TIMES WHEN BELL RINGS the full product name. Please BE TO BE HANDLED ONLY EY AUTHOR ZED PERSON OR CALL specify the quantity and type. BY EMPLOYEE CARING FOR SPR.NKLER SYSTEM IN CASE OF FIRE FIRE DEPT OR POLICE Hardware for hanging is not DO NOT SHUT VALVE UNTIL FIRE IS ENTIRELY OUT supplied with the Sign. It must be WHEN VALVE iS SHUT FOR EMERGENCY•REPAIRS-OR FiRE- NOTIFy ordered separately. Availability and Service: REQUEST DIRECTIONS..RESTORE PROTECTION QUICKLY Central sprinklers,accessories, and other products are available The blank spaces on this sign may throughout the U.S. and Canada, be utilized to provide message and internationally through a flexibility. Simply add combinations of Sign -Type E network of Central Sprinkler sign Type B and Type C as desired. • HYDRAULIC-SYSTEM • distribution centers.You may This Building is Protected by a write directly to Central Sprinkler Sign-Type B Hydraulically Designed Automatic Company, or call(215)362-0700 Sprinkler System • • for the distributor nearest you. AUXILIARY DRAIN Location Guarantee: Central Sprinkler No. of Sprinklers Company will repair and/or • •- replace any products found to be Basis of Design defective in material or 1 DENsITY GPM/SO.FT. Sign-Type C workmanship within a period of yP 2 DESIGNED AREA OF DISCHARGE WEFT. one year from date of shipment. System Demand Please refer to the current Price FRONT List for further details of the 1 ISU ER FLOW RATE GPM 2. RESIDUAL PRES,CE AT THE PSI HST :.TEE(;F E'FL '.---'.._E CC C;FE "I T LASE OF THE RISER Conversion Table: ._��[ •F .,. - . 2TI A • • 1 inch =25.400 mm BACK 1 foot=0.3048 M 1 pound=0.4536 kg oPEN Conversions are approximate. CENTRAL _.„„,_ 1 Central Sprinkler Company 451 N.Cannon Avenue, Lansdale,PA 19446 21 2- 7 ©1995 Central Sprinkler Company Phone(215)36 0 00 Printed in U.S.A. FAX (215)362-5385 Signs.1 t • + 122 CkASHCROFF" Fire Protection,Sprinkler Service Gauge Type 1005P,XUL f. ASME B 40.1 Grade B (±3-2-3%of span) : F 4. •Underwriters Laboratory listed and Ashcroft®fire protection sprinkler I Factory Mutual approved gauges are Underwriters Laboratory (`+rrr i •Corrosion-resistant ABS case listed and Factory Mutual approved % ISO f,.`R• for fire protection sprinkler service. 120 ISO t •Heat-resistant polycarbonate The case material on Type 1005P, 90 210 � , 1' push-in window XUL gauges is ABS.The 0-300 psi r:b0 240 . •Patented PowerFlex*M movement pressure range is used on"wet" ° 270 with polyester segment systems where water is available to ),•30 '°, the sprinkler heads.The 0-80 retards + •* � 300 •True Zero TM indication, a unique to 250 psi pressure range is used on + •' �`�' P P 9 ' safety feature dry systems where the lines are ' filled with air pressure until system t. activation. The patented PowerFlex move- ment with polyester segment is designed to provide unequalled True Zero indication, a standard shock and vibration resistance feature on these gauges, reduces resulting in superior performance the potential risk of installing a dam- and extended gauge life. aged gauge on your equipment. s GAUGE SPECIFICATIONS GAUGE OPTIONS Type no.: 1005P,XUL Operating Customized dials t Accuracy: ASME B 40.1 Grade B temperature: —40°F to 150°F i Other UL listed ranges on application i (t3-2-3%of span) Connection: 1/4 NPT lower ( Size: 31/2" Ranges: 0-300 psi(water) Case: ABS(Polycarbonate blend) 0-80 retard to 250 psi(air) UL 393 Listed,UL of Canada Ring: None Listed and FM approved. Window: Polycarbonate,push-in Equivalent(single or dual Dial: Black figures on white back- scale)metric scales are ground available NOTES ( Pointer: Black,aluminum LISTED I Bourdon tube: "C"shaped bronze Movement: Patented PowerFlex it with polyester segment 41> 5 Socket. Brass LOOK FONTNESE AGENCY YANKS ON OUR RIOOUCTS Restrictor: None { 1 TO ORDER THIS TYPE 1005P,XUL GAUGE: Select: 35 W 1005 P H 02L XUL 300# 1. Dial Size:3W 2. Patented PowerF/ex m Movement } 3. Case Type Number:1005 1 4. Case Type Material:ABS 5. Socket Material:Brass 6. Connection Size/Location:'/,NPT lower 7. UL listed,FM approved 8. Range:300 psi € Consult factory for guidance in product selection ---"""44 Phone(203)385-0217,Fax(203)385-0602 or DRESSER. visit our web site at www.ashcroft.com Instruments 1 ■ CENTRAL Hd. Cab. 11 -94 Sprinkler Head Central Sprinkler Company 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Product Technical 3, 6 & 12 Description n Data Head Central Sprinkler Head Cabinets Model: Sprinkler Head Cabinet Sprinkler are constructed of a metal enclosure Style: 3,6 or 12 head with a hinged cover designed to Head Standard Finish: Red enamel provide on-site storage of an emergency supply of sprinkler heads Mfgr. Source: Non-domestic and a sprinkler head wrench. Capacity: 3 sprinkler heads Cab i net NFPA 13 requires a representative 6 sprinkler heads number of each type of sprinkler 12 sprinkler heads head used in a sprinkler system to be Dimensions: stored in a cabinet on-site to allow for immediate removal and replacement 3 head-5"high x 7f"long x 2f"deep of sprinklers which may have 6 head-5"high x 14"long x 3W deep operated or become damaged. 12 head-5"high x 143A" long x 5"deep Central Sprinkler Head Cabinets Weight: 3 head- 1.5 lbs. are manufactured of heavy gauge 6 head-2.3 lbs. steel with knock-outs to 12 head-4 lbs. accommodate either W'or 3/<" N.P.T. threaded sprinkler heads and are painted an attractive red enamel. They are available in three(3),six(6) or twelve(12)head capacity. No.28-6.0 • [ Installation il Care & At Ordering Maintenance wig Information y 1 Central's Sprinkler Head Cabinet is The Cabinet,wrench,and stock of When placing an order, indicate the i designed with two 3A6"diameter holes spare sprinklers should be inspected full product name. Please specify the To7 wall mounting or direct attachment at least quarterly. The following items quantity, model,style,capacity, and to the system riser with a strap-type should be checked: size. i hanger. The Cabinet should be Sprinklers,wrenches, and hard- installed at or near the system control 1. The Cabinet should be readily ware for hanging are not supplied ; valve and must be stocked with an accessible, and not exposed to with the Cabinet. They must be adequate supply of spare sprinklers a corrosive atmosphere or ordered separately. I` and a sprinkler wrench. temperatures in excess of , The stock of spare sprinklers 100°F/38°C. Availability and Service: Central I should include sprinklers of each type sprinklers, accessories,and other and temperature rating as are 2. The stock of spare sprinklers products are available throughout the installed in the sprinkler system, in should include an adequate U.S.and Canada,and internationally the following quantities: number of each type and through a network of Central I temperature rating. Sprinkler distribution centers. You I Sprinklers Spare Sprinklers may write directly to Central Sprinkler t In System Required 3. The stock of sprinklers must be Company,or call(215)362-0700 for t in good condition. the distributor nearest you. I under 300 6 300-1000 12 4. A sprinkler wrench of the Guarantee: Central Sprinkler t over 1000 24 appropriate type must be Company will repair and/or replace included in the Cabinet. any products found to be defective in i The Cabinets are designed to material or workmanship within a I accept both f"and 3/4"N.P.T. period of one year from date of s threaded sprinklers. For f"N.P.T. shipment. Please refer to the current I sprinklers, leave the removable P Price List for further details of the K knockout in the hole. For%"N.P.T. warranty. I sprinklers, insert a screwdriver blade from the front top of the shelf and Conversion Table: t under the near bottom part of the 1 inch=25.400 mm t knockout annular ring. Press the 1 foot=0.3048 M t screwdriver handle down to remove 1 pound=0.4536 kg the knockout ring. The hole,with the knockout ring removed,will accept a 9 P Conversions are approximate. %"N.P.T.sprinkler. i I t i i s t I I 41111M1 I 1g CENTRAL ______ , Central Sprinkler Company 451 North Cannon Avenue,Lansdale,PA 19446 ©1994 Central Sprinkler Company Phone(215)362-0700 4 Printed in U.S.A. FAX (215)362-5385 Hd.Cab.2 C i I. I i 0 -- I ",;";. Hl1 D SKNGa . P 5151 Bannock . Denver, CO 80A' 303 -291 - 101 . 313 - 383 - 5023 F firespri . kler@a sco . com A FI 'I ' ' ' KLER DESIGN COMPANY