Loading...
HomeMy WebLinkAboutB12-0284 � Community Development Department 75 South Frontage Road Vail, Colorado USA 81657 CERTIFICATE OF OCCUPANCY This certificate is issued pursuant to the requirements of Title 10, Section 10-1-2, ADOPT'ED CODES of the Vail Town Code certifying that, at the time of issuance, this structure was found to be substantially in compliance with the various ordinances of the town regulating building construction or use for the following: New Duplex (primary side) Name and description of project 4898 Meadow Lane, Vail Cotorado 81657 Address of project: Owner name and address: 2009 IRC IBC Edition: Scott, Mark J. &Jacqueline K. 3471 S. Race Street Englewood,Co, 80113-3137 Occupancy Group(s) B12-0284 Permit Number(s): Occupant Load: Martin Haeberle,Chief Building Official R3 uB Type(s)of Construction: _ N/A N Sprinkler System Y/N Type: 11/18/2013 Date NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES 7►*VA' Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B12 -0284 Job Address: 4898 MEADOW DR VAIL Location......: primary side Parcel No....: 210113104022 Project #: PRJ11 -0451 Applied.....: 07/06/2012 Issued...: 08/28/2012 OWNER SCOTT, MARK J & JACQUELINE K 07/06/2012 3471 S RACE ST ENGLEWOOD CO 80113 -3137 CONTRACTOR NOVA GROUP, THE 07/17/2012 Phone: 970 - 390 -0931 DAVID IRWIN PO BOX 3342 VAIL CO 81657 License: C000003558 APPLICANT SCOTT, MARK R & JACQUELINE K 07/06/2012 4371 S RACE ST ENGLEWOOD CO 80113 -3137 Description: NEW DUPLEX Occupancy: R -3 Type Construction: VB Valuation: $552,000.00 xxwwwww wxfrwwww► xxwwwrrw, vwwwwwwwwwwwwwxwwwwwwwsewr�wwwwwwwwww FEE SUMMARY Building Permit - - - -> $3,480.75 Bldg Plan Check - - -> $2,262.49 Use Tax Fee > $10,840.00 Electrical Permit > $402.50 Elec Plan Check – > $261.63 Restuarant Plan Review —> $0.00 Mechanical Permit —> $440.00 Mach Plan Check - > $110.00 Additional Fees— > $0.00 Plumbing Permit - -> $690.00 Plmb Plan Check - -> $172.50 Recreation Fee— > $523.50 Investigation— —> $0.00 Will Call > $20.00 TOTAL PERMIT FEES— > $19,313.37 Payments– > $19,313.37 BALANCE DUE -> $0.00 www�rwwxwwmwxrewwwxwwwwxwwwx► wwww+ rxwwwwww+. xw► w► www+ rwwwwwwwxxxxwwwwwwwfxwxxw► xxwxxtwxxwxwwwwxwwwwwxmmmx:► wwxxwrxwwxxxweww► xxwwxxwx►► xxxxwxxrwxwwxxw ►xxx :x :xxxxwxwwxwxwwewxwxwxx► DECLARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. IREQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM. combination permit- 012811 CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #:, B12 -0284 Address: 4898 MEADOW DR VAIL Owner: SCOTT, MARK J & JACQUELINE K Location: primary side Cond: 52 (FIRE 2002) Monitored fire alarm system required and shall comply with NFPA 72 (2002 ed.) and VFES Standards Cond: 51 (FIRE 2007): MONITORED FIRE ALARM SYSTEM REQUIRED AND SHALL COMPLY WITH NFPA 72(2007) AND VFES STANDARDS. Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 I combination permit-012811 TowxOFvAILv REQUIRED INSPECTIONS AND STATUSES Permit #: B12 -0284 Owner: SCOTT, MARK J & JACQUELINE K primary side Address: 4898 MEADOW DR VAIL Location: Item: 00010 BLDG - FOOTING 08/21/2012 By: sgremmer Action: PI Comments: still need to see all interior pads Item: 00020 BLDG - Foundation /Steel Item: 00021 PLAWILC Foundation Plan Item: 00110 ELEC- Service Item: 00120 ELEC -Rough Item: 00200 MECH -Rough Item: 00210 PLM B-U nderg round Item: 00220 PLMB- Rough /D.W.V. Item: 00230 PLMB- Rough/Water Item: 00240 PLMB -Gas Piping Item: 00310 MECH- Heating Item: 00320 MECH- Exhaust Hoods Item: 00410 Special Inspect- progress rept Item: 00022 PLAWILC FRAMING Item: 00030 BLDG - Framing Item: 00050 BLDG - insulation Item: 00060 BLDG - Sheetrock Nail Item: 00190 ELEC -Final Item: 00290 PLMB -Final Item: 00390 MECH -Final Item: 00420 Special Inspect -final rept Item: 00540 BLDG -Final C/O Item: 00542 PLAN -FINAL Item: 00090 BLDG -Final combination permit-012811 TOWN OF VAIL, COLORADO Statement Statement Number: R120001187 Amount: $110.00 08/28/201201:34 PM Payment Method: Check Init: LC Notation: #11703 / david irwin, nova group ----------------------------------------------------------------------------- Permit No: B12 -0284 Type: COMBINATION BLDG PERMIT Parcel No: 2101 - 131 - 0402 -2 Site Address: 4898 MEADOW DR VAIL Location: primary side Total Fees: $19,313.37 This Payment: $110.00 Total ALL Pmts: $19,313.37 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- PF 00100003112300 PLAN CHECK FEES 110.00 70iMN OF VA Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970 - 479 -2128 www.vailgov_com vDevelopment Review Coordinator TRANSMITTAL FORM Revision Submittals: 1. "Field Set" of approved plans MUST accompany revisions. 2. No further inspections will be performed until the revisions are approved & the permit is re- issued. 3. Fees for reviewing revisions are $55.00 per hour (2 hour minimum), and are due upon issuance. Permit #(s) information applies to: 1.2- -- �-8 /Z - n_v3 Project Street Address: Attention: ,Number) (Street) (Suite #) Building /Complex Name: Contractor Information Business Name: D19 V;0�_ Business Address: city y ? / L_ /gyp v I° State: Zip: Contact Name: i\o(✓ Klt—fzopa Q Contact Phone: Contact E -Mail: �� N . �r ,r►/� -i1 ' Cori I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning d sub 'vision codes, design review ap- proved, err i I in and Residential Codes and other ordin ces a cable thereto. wKer /Owners Representative Signature (Required) Applicant Information Applicant Name: Applicant Phone: I Applicant E -Mail: For Office Use Only: Fee Paid: Received From: Cash Check # _ CC: Visa / MC Last 4 CC # Auth # exp. date: Revisions () Response to Correction Letter _attached copy of correction letter ( ) Deferred Submittal ( ) Other Description / List of Changes: (use additional sheet if necessary) Revised ADDITIONAL Valuations (Labor & Materials) (DO NOT include original valuation) Building: $ Plumbing: $ Electrical: $ Mechanical: $ Total: $ Date Received: AUG 15 1012 Y: isPm TOWN OF VA�I�L' JR Mond From: Sent: To: Subject: Hi JR, Primary 3490 s/f .electrical: $34,000 .plumbing: $46,000 .mechanical: $22,000 .building: $450,000 Secondary 3084 s/f .electrical: $26,000 .plumbing: $34,000 .mecanical:$18,000 .building: $370,000 Hope this helps, Dave 0 DAVID IRWIN <snapoutofit2 @msn.com> Monday, July 16, 2012 12:12 PM JR Mondragon RE: permit do C)303 2,0 O&PSY From: JMondragonc@vailciov.com To: sna outofit2 msn.c m Subject: permit Date: Mon, 16 Jul 2012 6:55:49 +0000 Greeting Dave, On the new duplex in eat vail, we need to assign 2 building permits to it. So I need your break down on the valuations for each side separate. The primary side is 3490 sq ft the secondary side is 3084 sq ft. Need breakdown on bull ing ,electrical, plumbing, mechanical. (ea) thanks Florencio Mondragon r Senior Building Inspecto /Plans Examiner Community Developme TOWN OF VAIL 970.479.2143 970.376.2673 vailgov.com twitter.com /vailgov 1 TOWN OF VAIL Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970 - 479 -2128 - www.vailgov.com Development Review Coordinator TRANSMITTAL FORM Revision Submittals: 1. "Field Set" of approved plans MUST accompany revisions. 2. No further inspections will be performed until the revisions are approved & the permit is re- issued. 3. Fees for reviewing revisions are $55.00 per hour (2 hour minimum), and are due upon issuance. Permit #(s) information applies to: Attention: ( ) Revisions 0 )Q � ( ) Response to Correction Letter I _attached copy of correction letter ( ) Deferred Submittal ( ) Other Project Street Address: (Number) (Street) (Suite #) Building /Complex Name: &,,- ke Ij / ewc C Contractor Information Business Name: �i`�F /I/ d V,4 6 Business Address: 33 ,4Z City ! State: �� Zip: Ezatf Contact Name: G!% / ni Contact Phone: Contact E -Mail: ���%ptlT�© r Z �' /&oj, noat I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review ap- proved, International Building and Residential Codes and other ordinan s f the To Ji ap icable thereto. X Owner /Owner's Representative Signature (Required) Applicant Information Applicant Name: _5Q1N1^ =- 6A0 Cx�oeg Applicant Phone: Applicant E -Mail: For Office Use Only: Fee Paid: Received From: Cash Check # _ CC: Visa / MC Last 4 CC # Auth # exp. date: Description / List of Changes: • c s av � e [r?S i4eC Z/V /l S (use additional sheet if necessary) Revised ADDITIONAL Valuations (Labor & Materials) (DO NOT include original valuation) Building: $ Plumbing: Electrical: $ Mechanical: $ [Total: $ AIA- Date Received: pED� iJUL 09 2012 WC IaY`1 TOWN OF VAI Job Name: --SCOTT p Sr a )n, L. 'n f J.^b Ar�lrireSc %✓�BALp111%f�Lt) ✓ >D:!°tl, TOM OF Permit No.: SPECIAL INSPECTION AND TESTING AGREEMEN I (To applicants of projects requiring Special Inspection or Testing per Section 1701 of the IBC) The owner or his /her representative, on the advice of the design professional in responsible charge, shall complete, seal, sign and submit a copy of the Special Inspection Agreement and Structural Tests Scheduled to the Town of Vail for review and approval. Signatures are required on both pages-, photocopied or faxed signatures are acceptable. The owner and his/her general contractor, where applicable, shall also acknowledge the following conditions applicable to Special Inspection Tesliray. 1. Contractor is responsible for proper notification to the Inspection or Testing agency for items listed.(Page 1) (IBC 1704) 2. Only the testing laboratory should take samples and transport them to their laboratory. 3. Copies of all laboratory reports and inspections are to be sent directly to the Town of Vail by the Testing agency on a weekly basis - 4. Inspection agency to submit names and qualifications of on -site special inspectors to the Town of Vail for review and approval.( Page 2) 5. The special inspector is responsible to immediately notify the Town of Vail Building Official in writing of any concerns and/or problems encountered. & It is the responsibility of the contractor to review the Town of Vail approved plans for additional inspection or testing requirements that may be noted. A pre - construction conference at the job site is recommended to review special inspection procedures. 7. The special inspector shall use only the Town of Vail approved drawings. 8. All special inspection field reports must be left on site for review by the Town of Vail staff prior to required inspections or re- inspections. BEFORE OCCUPANCY WILL BE GRANTED: The special inspection agency shall submit a signed and sealed statement that all items requiring testing and inspection were fulfilled and reported. Those items not tested and /or inspected shall be noted in this statement. A copy of the statement shall be maintained at the job site for the Building Inspector's review prior to final inspection. Acknowledgement: Owner: Special Agency: Project Arch /En Contractor: Jq)R r 7- Print Name bate 01;9 dtZ 1�o i 9 r uA10 Print N me ate (1);4 L) ( fo _1 11UJIto /L Print Name Oate Z2'w'� (1/ t) 110 at w I!) '`1 1,211 z Signature Print Name ate j- im CNJ(REScheck Software Version 4.4.3 Compliance Certificate Project Title: Scott Residence Unit "A" Energy Code: 2009 IECC Location: Vail, Colorado Construction Type: Single Family Glazing Area Percentage: 43% Heating Degree Days: 9248 Climate Zone: 6 Construction Site: 4898 Meadow Lane Vail, CO 81658 Permit # B Permit Date: 7 Owner /Agent: David Irwin The Nova Group P.O.Box 3342 Vail, CO 81658 970- 390 -0931 snapoutofit2 @msn.com Compliance: 7.0% Better Than Code Maximum UA: 512 Your UA: 476 The % Better or Worse Than Code index reflects how close to compliance the house is based on code tradeoff rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Designer /Contractor: David Irwin The Nova Group P.O.Box 3342 Vail, CO 81658 970 - 390 -0931 snapoutofit2 @msn.com Ceiling 1: Flat Ceiling or Scissor Truss 1329 49.0 0.0 35 Ceiling 2: Cathedral Ceiling 600 49.0 0.0 13 Wall 1: Wood Frame, 16" o.c. 2100 21.0 0.0 67 Window 1: Metal Frame:Triple Pane with Low -E 900 0.290 261 Door 1: Solid 24 0.290 7 Floor 1: All -Wood Joist/Truss:Over Unconditioned Space 1560 19.0 0.0 73 Floor 2: All -Wood Joist/fruss:Over Unconditioned Space 600 30.0 0.0 20 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in REScheck Version 4.4.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name - Title Signature Date Project Title: Scott Residence Unit "A" Data filename: Untitled.rck JUL 0 2012 TOWN OF VAIL Report date: 07/09/12 Page 1 of 4 CNJ(REScheck Software Version 4.4.3 Inspection Checklist Energy Code: 2009 IECC Location: Vail, Colorado Construction Type: Single Family Glazing Area Percentage: 43% Heating Degree Days: 9248 Climate Zone: 6 Ceilings: ❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-49.0 cavity insulation Comments: ❑ Ceiling 2: Cathedral Ceiling, R-49.0 cavity insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, 16" o.c., R -21.0 cavity insulation Comments: Windows: ❑ Window 1: Metal Frame:Triple Pane with Low -E, U- factor: 0.290 For windows without labeled U- factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1: Solid, U- factor: 0.290 Comments: Floors: ❑ Floor 1: All -Wood Joist/Truss:Over Unconditioned Space, R -19.0 cavity insulation Comments: Floor insulation is installed in permanent contact with the underside of the subfloor decking. ❑ Floor 2: All -Wood Joist/Truss:Over Unconditioned Space, R -30.0 cavity insulation Comments: Floor insulation is installed in permanent contact with the underside of the subfloor decking. Air Leakage: ❑ Joints (including rim joist junctions), attic access openings, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed with caulk, gasketed, weatherstripped or otherwise sealed with an air barrier material, suitable film or solid material. ❑ Air barrier and sealing exists on common walls between dwelling units, on exterior walls behind tubs /showers, and in openings between window /doorjambs and framing. ❑ Recessed lights in the building thermal envelope are 1) type IC rated and ASTM E283 labeled and 2) sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. ❑ Access doors separating conditioned from unconditioned space are weather - stripped and insulated (without insulation compression or damage) to at least the level of insulation on the surrounding surfaces. Where loose fill insulation exists, a baffle or retainer is installed to maintain insulation application. ❑ Wood- burning fireplaces have gasketed doors and outdoor combustion air. ❑ Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. Air Sealing and Insulation: ❑ Building envelope air tightness and insulation installation complies by either 1) a post rough -in blower door test result of less than 7 ACH at 50 pascals OR 2) the following items have been satisfied: Project Title: Scott Residence Unit "A" Report date: 07/09/12 Data filename: Untitled.rck Page 2 of 4 (a) Air barriers and thermal barrier: Installed on outside of air - permeable insulation and breaks or joints in the air barrier are filled or repaired. (b) Ceiling /attic: Air barrier in any dropped ceiling /soffit is substantially aligned with insulation and any gaps are sealed. (c) Above -grade walls: Insulation is installed in substantial contact and continuous alignment with the building envelope air barrier. (d) Floors: Air barrier is installed at any exposed edge of insulation. (e) Plumbing and wiring: Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing, or sprayed /blown insulation extends behind piping and wiring. (f) Corners, headers, narrow framing cavities, and rim joists are insulated. (9) Shower /tub on exterior wall: Insulation exists between showers /tubs and exterior wall. Sunrooms: Li Sunrooms that are thermally isolated from the building envelope have a maximum fenestration U- factor of 0.50 and the maximum skylight U- factor of 0.75. New windows and doors separating the sunroom from conditioned space meet the building thermal envelope requirements. Materials Identification and Installation: Materials and equipment are installed in accordance with the manufacturer's installation instructions. Materials and equipment are identified so that compliance can be determined. Li Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. Li Insulation R- values and glazing U- factors are clearly marked on the building plans or specifications. Duct Insulation: FI Supply ducts in attics are insulated to a minimum of R -8. All other ducts in unconditioned spaces or outside the building envelope are insulated to at least R -6. Duct Construction and Testing: F1 Building framing cavities are not used as supply ducts. F-1 All joints and seams of air ducts, air handlers, filter boxes, and building cavities used as return ducts are substantially airtight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Tapes, mastics, and fasteners are rated UL 181A or UL 181B and are labeled according to the duct construction. Metal duct connections with equipment and /or fittings are mechanically fastened. Crimp joints for round metal ducts have a contact lap of at least 1 1/2 inches and are fastened with a minimum of three equally spaced sheet -metal screws. Exceptions: Joint and seams covered with spray polyurethane foam. Where a partially inaccessible duct connection exists, mechanical fasteners can be equally spaced on the exposed portion of the joint so as to prevent a hinge effect. Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). Lj Duct tightness test has been performed and meets one of the following test criteria: (1) Postconstruction leakage to outdoors test: Less than or equal to 279.1 cfm (8 cfm per 100 ft2 of conditioned floor area). (2) Postconstruction total leakage test (including air handler enclosure): Less than or equal to 418.7 cfm (12 cfm per 100 ft2 of conditioned floor area). (3) Rough -in total leakage test with air handler installed: Less than or equal to 209.3 cfm (6 cfm per 100 ft2 of conditioned floor area). (4) Rough -in total leakage test without air handler installed: Less than or equal to 139.6 cfm (4 cfm per 100 ft2 of conditioned floor area). Temperature Controls: Where the primary heating system is a forced air - fumace, at least one programmable thermostat is installed to control the primary heating system and has set - points initialized at 70 degree F for the heating cycle and 78 degree F for the cooling cycle. Lj Heat pumps having supplementary electric- resistance heat have controls that prevent supplemental heat operation when the compressor can meet the heating load. Heating and Cooling Equipment Sizing: ❑ Additional requirements for equipment sizing are included by an inspection for compliance with the International Residential Code. Lj For systems serving multiple dwelling units documentation has been submitted demonstrating compliance with 2009 IECC Commercial Building Mechanical and /or Service Water Heating (Sections 503 and 504). Circulating Service Hot Water Systems: F-i Circulating service hot water pipes are insulated to R -2. Lj Circulating service hot water systems include an automatic or accessible manual switch to turn off the circulating pump when the system is not in use. Project Title: Scott Residence Unit "A" Report date: 07/09112 Data filename: Untitled.rck Page 3 of 4 Heating and Cooling Piping Insulation: HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to R -3. Swimming Pools: F1 Heated swimming pools have an on /off heater switch. F-1 Pool heaters operating on natural gas or LPG have an electronic pilot light. Lj Timer switches on pool heaters and pumps are present. Exceptions: Where public health standards require continuous pump operation. Where pumps operate within solar- and /or waste - heat - recovery systems. Lj Heated swimming pools have a cover on or at the water surface. For pools heated over 90 degrees F (32 degrees C) the cover has a minimum insulation value of R -12. Exceptions: Covers are not required when 60% of the heating energy is from site - recovered energy or solar energy source. Lighting Requirements: F1 A minimum of 50 percent of the lamps in permanently installed lighting fixtures can be categorized as one of the following: (a) Compact fluorescent (b) T -8 or smaller diameter linear fluorescent (c) 40 lumens per watt for lamp wattage — 15 (d) 50 lumens per watt for lamp wattage > 15 and — 40 (e) 60 lumens per watt for lamp wattage > 40 Other Requirements: Li Snow- and ice - melting systems with energy supplied from the service to a building shall include automatic controls capable of shutting off the system when a) the pavement temperature is above 50 degrees F, b) no precipitation is falling, and c) the outdoor temperature is above 40 degrees F (a manual shutoff control is also permitted to satisfy requirement V). Certificate: F1 A permanent certificate is provided on or in the electrical distribution panel listing the predominant insulation R- values; window U- factors; type and efficiency of space - conditioning and water heating equipment. The certificate does not cover or obstruct the visibility of the circuit directory label, service disconnect label or other required labels. NOTES TO FIELD: (Building Department Use Only) Project Title: Scott Residence Unit "A" Report date: 07/09/12 Data filename: Untitled.rck Page 4 of 4 / 2009 IECC Energy d Efficiency Certificate Ceiling / Roof 49.00 Wall 21.00 Floor / Foundation 19.00 Ductwork (unconditioned spaces): Window Door Heating System: Cooling System: Water Heater: 0.29 0.29 NA Name: Date: Comments: CNJ(REScheck Software Version 4.4.3 Compliance Certificate Project Title: Scott Residence Unit "B" Energy Code: 2009 IECC Location: Vail, Colorado Construction Type: Single Family Glazing Area Percentage: 44% Heating Degree Days: 9248 Climate Zone: 6 Construction Site: 4898 Meadow Lane Vail, CO 81658 Permit # B Permit Date: 7 Owner /Agent: David Irwin The Nova Group P.O.Box 3342 Vail, CO 81658 970 - 390 -0931 snapoutofit2@msn.com Compliance trade-off Compliance: 7.3% Better Than Code Maximum UA: 453 Your UA: 420 The % Better or Worse Than Code index reflects how dose to compliance the house is based on code tradeoff rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Designer /Contractor: David Irwin The Nova Group P.O.Box 3342 Vail, CO 81658 970 - 390 -0931 snapoutofit2 @msn.com Ceiling 1: Flat Ceiling or Scissor Truss 1450 49.0 0.0 38 Ceiling 2: Cathedral Ceiling 400 49.0 0.0 9 Wall 1: Wood Frame, 16" o.c. 1800 21.0 0.0 56 Window 1: Metal Frame:Triple Pane with Low -E 800 0.290 232 Door 1: Solid 24 0.290 7 Floor 1: All -Wood Joist/Truss:Over Unconditioned Space 1234 19.0 0.0 58 Floor 2: All -Wood Joist/Truss:Over Unconditioned Space 600 30.0 0.0 20 Compliance Statement The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in REScheck Version 4.4.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name - Title Signature Date Project Title: Scott Residence Unit "B" Report date: 07/09/12 Data filename: Untitled.rck Page 1 of 4 CNJ(REScheck Software Version 4.4.3 Inspection Checklist Energy Code: 2009 IECC Location: Vail, Colorado Construction Type: Single Family Glazing Area Percentage: 44% Heating Degree Days: 9248 Climate Zone: 6 Ceilings: ❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-49.0 cavity insulation Comments: ❑ Ceiling 2: Cathedral Ceiling, R-49.0 cavity insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, 16" o.c., R -21.0 cavity insulation Comments: Windows: ❑ Window 1: Metal Frame:Triple Pane with Low -E, U- factor: 0.290 For windows without labeled U- factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1: Solid, U- factor: 0.290 Comments: Floors: ❑ Floor 1: All -Wood Joist/Truss: Over Unconditioned Space, R -19.0 cavity insulation Comments: Floor insulation is installed in permanent contact with the underside of the subfloor decking. ❑ Floor 2: All -Wood Joist/Truss:Over Unconditioned Space, R -30.0 cavity insulation Comments: Floor insulation is installed in permanent contact with the underside of the subfloor decking. Air Leakage: ❑ Joints (including rim joist junctions), attic access openings, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed with caulk, gasketed, weatherstripped or otherwise sealed with an air barrier material, suitable film or solid material. r❑ Air barrier and sealing exists on common walls between dwelling units, on exterior walls behind tubs /showers, and in openings between window /door jambs and framing. ❑ Recessed lights in the building thermal envelope are 1) type IC rated and ASTM E283 labeled and 2) sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. ❑ Access doors separating conditioned from unconditioned space are weather- stripped and insulated (without insulation compression or damage) to at least the level of insulation on the surrounding surfaces. Where loose fill insulation exists, a baffle or retainer is installed to maintain insulation application. ❑ Wood - burning fireplaces have gasketed doors and outdoor combustion air. ❑ Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. Air Sealing and Insulation: ❑ Building envelope air tightness and insulation installation complies by either 1) a post rough -in blower door test result of less than 7 ACH at 50 pascals OR 2) the following items have been satisfied: Project Title: Scott Residence Unit "B" Report date: 07/09/12 Data filename: Untitled.rck Page 2 of 4 (a) Air barriers and thermal barrier: Installed on outside of air - permeable insulation and breaks or joints in the air barrier are filled or repaired. (b) Ceiling /attic: Air barrier in any dropped ceiling /soffit is substantially aligned with insulation and any gaps are sealed. (c) Above -grade walls: Insulation is installed in substantial contact and continuous alignment with the building envelope air barrier. (d) Floors: Air barrier is installed at any exposed edge of insulation. (e) Plumbing and wiring: Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing, or sprayed /blown insulation extends behind piping and wiring. (0 Corners, headers, narrow framing cavities, and rim joists are insulated. (9) Shower /tub on exterior wall: Insulation exists between showers/tubs and exterior wall. Sunrooms: ❑ Sunrooms that are thermally isolated from the building envelope have a maximum fenestration U- factor of 0.50 and the maximum skylight U- factor of 0.75. New windows and doors separating the sunroom from conditioned space meet the building thermal envelope requirements. Materials Identification and Installation: ❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions. F1 Materials and equipment are identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. F-1 Insulation R- values and glazing U- factors are clearly marked on the building plans or specifications. Duct Insulation: F1 Supply ducts in attics are insulated to a minimum of R -8. All other ducts in unconditioned spaces or outside the building envelope are insulated to at least R -6. Duct Construction and Testing: Building framing cavities are not used as supply ducts. ❑ All joints and seams of air ducts, air handlers, filter boxes, and building cavities used as return ducts are substantially airtight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Tapes, mastics, and fasteners are rated UL 181A or UL 181 B and are labeled according to the duct construction. Metal duct connections with equipment and /or fittings are mechanically fastened. Crimp joints for round metal ducts have a contact lap of at least 1 1/2 inches and are fastened with a minimum of three equally spaced sheet -metal screws. Exceptions: Joint and seams covered with spray polyurethane foam. Where a partially inaccessible duct connection exists, mechanical fasteners can be equally spaced on the exposed portion of the joint so as to prevent a hinge effect. Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). F-1 Duct tightness test has been performed and meets one of the following test criteria: (1) Postconstruction leakage to outdoors test: Less than or equal to 246.7 cfm (8 cfm per 100 ft2 of conditioned floor area). (2) Postconstruction total leakage test (including air handler endosure): Less than or equal to 370.1 cfm (12 cfm per 100 ft2 of conditioned floor area). (3) Rough -in total leakage test with air handler installed: Less than or equal to 185.0 cfm (6 cfm per 100 ft2 of conditioned floor area). (4) Rough -in total leakage test without air handler installed: Less than or equal to 123.4 cfm (4 cfm per 100 ft2 of conditioned floor area). Temperature Controls: Lj Where the primary heating system is a forced air- fumace, at least one programmable thermostat is installed to control the primary heating system and has set - points initialized at 70 degree F for the heating cycle and 78 degree F for the cooling cycle. Lj Heat pumps having supplementary electric - resistance heat have controls that prevent supplemental heat operation when the compressor can meet the heating load. Heating and Cooling Equipment Sizing: U Additional requirements for equipment sizing are included by an inspection for compliance with the International Residential Code. ❑ For systems serving multiple dwelling units documentation has been submitted demonstrating compliance with 2009 IECC Commercial Building Mechanical and /or Service Water Heating (Sections 503 and 504). Circulating Service Hot Water Systems: ❑ Circulating service hot water pipes are insulated to R -2. Lj Circulating service hot water systems include an automatic or accessible manual switch to turn off the circulating pump when the system is not in use. Project Title: Scott Residence Unit "B" Report date: 07/09/12 Data filename: Untitled.rck Page 3 of 4 Heating and Cooling Piping Insulation: F-1 HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to R -3. Swimming Pools: ❑ Heated swimming pools have an on /off heater switch. U Pool heaters operating on natural gas or LPG have an electronic pilot light. Li Timer switches on pool heaters and pumps are present. Exceptions: Where public health standards require continuous pump operation. Where pumps operate within solar- and /or waste - heat - recovery systems. Lj Heated swimming pools have a cover on or at the water surface. For pools heated over 90 degrees F (32 degrees C) the cover has a minimum insulation value of R -12. Exceptions: Covers are not required when 60% of the heating energy is from site - recovered energy or solar energy source. Lighting Requirements: F1 A minimum of 50 percent of the lamps in permanently installed lighting fixtures can be categorized as one of the following: (a) Compact fluorescent (b) T -8 or smaller diameter linear fluorescent (c) 40 lumens per watt for lamp wattage — 15 (d) 50 lumens per watt for lamp wattage > 15 and — 40 (e) 60 lumens per watt for lamp wattage > 40 Other Requirements: Snow- and ice - melting systems with energy supplied from the service to a building shall include automatic controls capable of shutting off the system when a) the pavement temperature is above 50 degrees F, b) no precipitation is falling, and c) the outdoor temperature is above 40 degrees F (a manual shutoff control is also permitted to satisfy requirement'c'). Certificate: Lj A permanent certificate is provided on or in the electrical distribution panel listing the predominant insulation R- values; window U- factors; type and efficiency of space - conditioning and water heating equipment. The certificate does not cover or obstruct the visibility of the circuit directory label, service disconnect label or other required labels. NOTES TO FIELD: (Building Department Use Only) Project Title: Scott Residence Unit "B" Report date: 07/09/12 Data filename: Untitled.rck Page 4 of 4 �J(2009 IECC Energy Efficiency Certificate Insulation Rating R-Value Ceiling / Roof 49.00 Wall 21.00 Floor / Foundation 19.00 Ductwork (unconditioned spaces): Glass & Door Rating U-Factor SHGC Window 0.29 Door 0.29 NA Heating System: Cooling System: Water Heater: Name: Date: Comments: TOWN OF VAIL/ Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970 - 479 -2128 www.vailgov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: Project #: flow ONE DRB #: to U 1 (Number) (Street) (Suite #) �7 Building Permit #: ;Building /Complex Name: ��Ot( SIQI =NGE Contractor Information Lot #: Block # Subdivision. Business Name: 11 n(tg nt)a GRDV Business Address: h7Dx�3� -¢ 2 City VA I( State: Co. Zip: B 16 S A Contact Name: I ✓ n 114u to 7_ w; m Contact Phone: q70 – 3g0- 0131 Work Class: New (x) Addition( ) Alteration ( ) Type of Building: Single - Family ( ) Duplex (><) Multi-Family( Commercial ( ) Other( Work Type: Interior ( ) Exterior ( )Both (x ) Contact E -Mail: �iVtA �(_ WTO-F LT 2 C, ► ,3A) • GOt>?'1 I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review ap- proved, International Building and Residential Codes and other ordinances of the Town applicable thereto. X ��. � Owner/Owner's Representative Signature (Required) Applicant Information %� Applicant Name: `I V J I iii Ywml oo Applicant Phone: 49n – Oct I Applicant E -Mail: XTjpl R lQ/9y To 7F tY 2 R. 011 S BV . GOW Project Information _ Owner Name: lIlAa.k SGo 1 _. Parcel #: 2 10 11 3 16 -4 0 2 2 I21011 310 4 6 2 3 (For Parcel #, contact Eagle County Assessifrs Office at (970- 328 -8640 or visit www.eaglecounty. uslpatie) For Office Use Only: Fee Paid: / _ "t 10 Received From: Cash Check # CC: Visa / MC Last 4 CC # exp date: Auth # Valuation of Work Included Plans Included Work )c )Yes ( )No ( x)Yes ( )No 000 Mechanical ( X )Yes ( )No (-c )Yes ( )No 5D, oc) o i Plumbing (x )Yes ( )No (x )Yes ( )No 6 a: 0o 0O i Building ( X )Yes ( )No (;c )Yes ( )No 8_31; 000 Value of all work being performed: — $ 1.00o, oath (value based on IBC Section 109.3 & IRC Section 108.3) Electrical Square Footage Detailed Scope and Location of Work: -r-6 �P_ de, dno l (S 4e I (use additional sheet if Date Received: I I D Ip– � W E JUL 0 3 2012 TOWN OF VAIL 11 -27 -2013 Inspection Request Reporting Page 4 4:05 Dm Vaal, M city Of Requested Inspect Date: Friday, November 29, 2013 Site Address: 4898 MEADOW DR VAIL primary side A/P /D Information Activity: Const Type: 1312 -0284 Type: COMBO Occupancy: Owner: SCOTT, MARK J & JACQUELINE K Contractor: NOVA GROUP, THE Applicant: SCOTT, MARK R & JACQUELINE K Description: NEW DUPLEX Comment: REV1 RECEIVED. TRUSS PLAN FOR ROO Comment: RECEIVED THE SPFrIA1 w .qPFr.Tinni AN Comment: SCANNED Comment: TCO issuec Comment: REV1 CR1 Comment: RECEIVED SGREMMER ROUTED T Comment: ILC RECEI� U IM FOR APPROVAL. - D & ROUTED TO WARRE Requested Insuection(s) Item: 190 ELEC -Final �✓ Requestor: Comments: Comments: TCO Assigned To: SGREMMER Action: Comment: Time Exp: ina connec ion o hot tub. Comment: Sub Type: NDUP Status: ISSUED Use: R -3 Insp Area: Phone: 970 - 390 -0931 UTED TO G -1. - DRHOADES E AGRAGREEMENT. O JRM RESCHECK WAS PUT IN F 2 BILL G AND FIRE. - DRHOADES for 11/29 - MHAEBERLE ANFORMAT) ROUTED SCANNED TRANSM TRANSMITTAL FORM AND Item: 290 PLMB -Final Requestor: Comments: TCO Assigned To: SGREMMER Action: Comment: Time Exp: comp e e mas er bath and 2 showers in asemen Comment: . Item: 390 MECH -Final Requestor: Comments: TCO Assigned To: SGREMMER Action: Time Exp: Comment: comp e e snowmelt boiler. Comment: Item: 420 Special Inspect -final rept Requestor: Comments: TCO Assigned To: SGREMMER Action: Time Exp: Comment: Item: 540 BLDG -Final C/O Requestor: Assigned To: SGREMMER Action: Time Exp: Requested Time: 08:00 AM Phone: Entered By: MHAEBERLE K Requested Time: 08:30 AM Phone: Entered By: MHAEBERLE K Requested Time: 09:00 AM Phone: Entered By: MHAEBERLE K Requested Time: 09:30 AM Phone: Entered By: MHAEBERLE K Requested Time: 09:45 AM Phone: Entered By: MHAEBERLE K Inspection History Item: 543 PW FINAL ** Approved ** 11/12/13 Inspector: Is Action: AP APPROVED Comment: Item: 10 BLDG - FOOTING —Approved" REPT131 Run Id: 14778 - 11 -27 -2013 Inspection Request Reporting Page 7 4:05 p- - -- _ -_ Vail, CO - City Of Requested Inspect Date: Friday, November 29, 2013 Site Address: 4894 MEADOW LN VAIL 4898 meadow lane (secondary side) A /P /D Information Activity: B12 -0303 Type: COMBO Sub Type: NDUP Status: ISSUED Const Type: Occu anc Use: R -3 Insp Area: Owner: SCOTT, MARK J & JACQUELINE K Applicant: SCOTT, MARK R & JACQUELINE K Contractor: THE NOVA GROUP Phone: 970 - 390 -0931 Description: NEW DUPLEX Secondary side Comment: REV1 RECEIVED. TRUSS PLAN FOR ROOF. SCANNED TRANSMITTAL AND ROUTED TO G -1. - DRHOADES Comment: APIA in the amount of $1,500 was provided to cover the cost of the incomplete railing and light fixtures on teh primary side of the duplex. - WCAMPBELL Comment: RECEIVED ILC - ROUTED TO WARREN - SBELLM Comment: DIA Ok'd for release - WCAMPBELL Comment: SOILS REPORT. - JMONDRAGON Comment: RECEIVED TWO SETS OF SOILS REPORTS (PLAN FORMAT). SCANNED TRANSMITTAL FORM AND ROUTED TO JRM FOR APPROVAL. - DRHOADES Comment: In§ppection entetred for 11/30/2013 for CofO on both sides - MHAEBERLE Comment: REV1 CR1 RECEIVED. STAMPED TRUSS PLAN FOR ROOF. ROUTED TO G -1. - DRHOADES Requested Inspection(s) Item: 540 BLDG -Final C/O Requested Time: 10:45 AM Requestor: Phone: Assigned To: SGREMMER Entered By: MHAEBERLE K Action: Time Exp: Inspection History Item: 20 BLDG - Foundation /Steel " Approved *` 08/31/12 Inspector: nsc Action: AP APPROVED Comment: wall steel Item: 21 PLAN -ILC Foundation Plan '* Approved «* 06/07/13 Inspector: Warren Action: AP APPROVED Comment: Item: 10 BLDG - FOOTING **Approved** 08/21/12 Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: still need to see all interior pads 09/26/12 Inspector: sgremmer Action: AP APPROVED Comment: pads Item: 110 ELEC - Service Approved «« 10/11/12 Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: service laterals 06/11/13 Inspector: sgremmer Action: AP APPROVED Comment: Item: 120 ELEC -Rou h " Approved " 06/05/13 Inspector: sgremmer Action: DN DENIED Comment: Ufer ground required for service notch plate where required 06/10/13 Inspector: sgremmer Action: AP APPROVED Comment: Item: 200 MECH -Rough '« Approved *' 06/11/13 Inspector: sgremmer Action: AP APPROVED Comment: Item: 210 PLMB - Underground '* Approved *' 10101112 Inspector: sgremmer Action: AP APPROVED Comment: Item: 220 PLMB - Rough /D.W.V. '* Approved *« 06/11/13 Inspector: sgremmer Action: AP APPROVED Comment: Item: 230 PLMB -Rough /Water *' Approved *« 06/11/13 Inspector: sgremmer Action: AP APPROVED Comment: Item: 240 PLMB -Gas Piping " Approved " 06/11/13 Inspector: sgremmer Action: AP APPROVED Comment: 09/23/13 Inspector: sgremmer Action: AP APPROVED Comment: Item: 310 MECH - Heating " Approved '* 06/11/13 inspector: sgremmer Action: AP APPROVED Comment: REPT131 Run Id: 14778 NOTE: TH/S PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ,. �w�o�v�, . Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B12-0284 Project #: PRJ11-0451 Job Address: 4898 MEADOW DR VAIL Applied.....: 07/06/2012 Location......: primary side Issued. . . : 06/19/2013 Parcel No....: 210113104022 OWNER SCOTT, MARK J &JACQUELINE K 07/06/2012 3471 S RACE ST ENGLEWOOD CO 80113-3137 CONTRACTOR NOVA GROUP, THE 07/17/2012 Phone: 970-390-0931 DAVID IRWIN PO BOX 3342 � VAIL CO 81657 License: C000003558 APPLICANT SCOTT, MARK R & JACQUELINE K 07/06/2012 4371 S RACE ST ENGLEWOOD CO 80113-3137 Description: NEW DUPLEX Occupancy: R-3 Type Construction: VB Valuation: $552,000.00 ..,....,.,,...,...�..................�,,,.......,.....,+�....,.,.,.......,......_... FEE SUMMARY .........,,..........,,,.....,,.._.....,....................,,.............._..,,., Building Permit-----------> $3,480.75 Bldg Plan Check----------> $2,262.49 Use Tax Fee-----------------------> $10,840.00 Electrical Permit---------> $402.50 Elec Plan Check-----------> $261.63 Restuarant Plan Review--------> $0.00 Mechanical Permit------> $440.00 Mech Plan Check---------> $110.00 Additional Fees--------------------> $0.00 Plumbing Permit--------> $690.00 Plmb Plan Check---------> $172.50 Recreation Fee--------------------> $523.50 Investigation-----------------------> $0.00 Will Call------------------------------> $20.00 � TOTAL PERMIT FEES--------------> $19,643.37 Payments-------------------------------> $19,643.37 BALANCE DUE------------------------> $0.00 ....,...,...x.......«..................,.,.,,...,,...,._...,........,>.,...............,..._...,,.,.,...........,...........,,....,..,...................�....................�.....,,...... DECLARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM -4:00 PM. combination permit_012811 a � � ��I��4 1 4!��� 1 .x.•+�..xxx.,r.«�...�..........w..xxx.x.x..xx.w...•....++.•..r•.+.........x..x....x+.+...+...r•..•.e.•..��..+.•.x.».•.xw.x.xs.�••:..e.....+e..+r..xx.xx...x.•..x...+�............x.�w... CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF "� Permit#: 612-0284 Address: 4898 MEADOW DR VAIL Owner: SCOTT, MARK J &JACQUELINE K Location: primary side ....................:...................................................»,,......,,��...,............»...,......,.,..,.,�.,,.....,....,x......,.........,....................�........ Cond: 52 (FIRE 2002) Monitored fire alarm system required and shall comply with NFPA 72 (2002 ed.) and VFES Standards Cond: 51 -. (FIRE 2007): MONITORED FIRE ALARM SYSTEM REQUIRED AND SHALL COMPLY WITH NFPA 72(2007)AND VFES STANDARDS. Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 combination permit_012811 � � � 1 V T111 V� 1'#]t1.� • ****************************�**.,********««*****.,********«*,�************.,*********«,,,,«*****««*****,.,.***********««.,****«**.***,�*.*****,.**„�«******�*.** REQUIRED INSPECTIONS AND STATUSES � Permit#: 612-0284 Address: 4898 MEADOW DR VAIL Owner: SCOTT, MARK J & JACQUELINE K Location: primary side ****«****««********«****««.,*************,*****«*,.,,*,..******.****************«*««**«**,.*,,,..,***********************«****************««*«*******.*�***** Item: 00010 BLDG-FOOTING 08/21/2012 By: sgremmer Action: PI Comments: still need to see all interior pads 09/26/2012 By: sgremmer Action: AP Comments: pads 10/10/2012 By: sgremmer Action: AP Comments: slab Item: 00020 BLDG-Foundation/Steel 08/31/2012 By: nsc Action: AP Comments: wall steel Item: 00021 PLAN-ILC Foundation Plan 06/07/2013 By: Warren Action: AP Item: 00110 ELEC-Service 10/11/2012 By: sgremmer Action: PI Comments: service laterals 10/17/2012 By: sgremmer Action: PI Comments: Temp power 06/10/2013 By: sgremmer Action: AP Item: 00120 ELEC-Rough 06/05/2013 By: sgremmer Action: DN Comments: Notch plate where required. 06/10/2013 By: sgremmer Action: AP Item: 00200 MECH-Rough 06/11/2013 By: sgremmer Action: AP 06/12/2013 By: sgremmer Action: NR Comments: Infloor 06/13/2013 By: sgremmer Action: AP Comments: infloor heat Item: 00210 PLMB-Underground 10/01/2012 By: sgremmer Action: AP Item: 00220 PCMB-Rough/D.W.V. 04/12/2013 By: sgremmer Action: AP Item: 00230 PLMB-Rough/Water 04/12/2013 By: sgremmer Action: AP Item: 00240 PLMB-Gas Piping 04/12/2013 By: sgremmer Action: AP Item: 00310 MECH-Heating 10/10/2012 By: sgremmer Action: PI Comments: in floor heat al in slab at 100 PSI Item: 00320 MECH-Exhaust Hoods Item: 00410 Special Inspect-progress rept Item: 00022 PLAN-ILC FRAMING Item: 00030 BLDG-Framing �6/11/2013 By: sgremmer Action: DN Comments: Framing and Foundation ILC Submit new plans W/Truss system Support heel cuts Fire block fireplace chase Truss bracing per truss specs combination permit_012811 � Wrap panels in garage 06/17/2013 By: JRM Action: AP Item: 00050 BLDG-Insulation Item: 00060 BLDG-Sheetrock Nail 11/23/2012 By: JRM Action: AP Comments: PARTY WALL ONLY 2ND LEVEL Item: 00190 ELEC-Final Item: 00290 PLMB-Final Item: 00390 MECH-Final Item: 00420 Special Inspect-final rept Item: 00540 BLDG-Final C/O ttem: 00542 PLAN-FINAL Item: 00090 BLDG-Final combination permit_012811 ********+****************+******+*****�***************************************************** TOWN OF VAIL, COLORADOCopy Reprinted on 06-19-2013 at 14:37:01 06/19/2013 Statement ***************�****************+*�***********�*********************+********++***********+* Statement Number: R130000836 Amount: $330.00 06/19/201302:30 PM Payment Method: Check Init: CG Notation: ck 11781 david lawrence irwin ----------------------------------------------------------------------------- Permit No: B12-0284 Type: COMBINATION BLDG PERMIT Parcel No: 2101-131-0402-2 Site Address: 4898 MEADOW DR VAIL Location: primary side Total Fees: $19, 643. 37 This Payment: $330.00 Total ALL Pmts: $19, 643. 37 Balance: $0.00 ***********************************�************************+******************************* ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ PF 00100003112300 PLAN CHECK FEES 330.00 -----------------------------------------------------------------------------