Loading...
HomeMy WebLinkAboutA12-0033 Stamped approved plans � O �� � LEGEND� � SYMBOL DEVICE DESCRIPTION � ❑F Manual Pull Station O OP Photoelectric Smoke Detector J . 3 J . 7 � W � W � Heat Detector (fixed) � � �� Horn/Strobe r�l � �-�-� O \�/ � ,�. Strobe (candela specified) E LEV. ` � � � ^ � Horn Only cu ~� � � J I I��� � � W Q � �-�-* Sprinkler Waterflow Switch 1 Ol l � Q �--� � ^ � (Q �� � �T, Sprinkler Valve Tamper Switch � � O � � O � � SB Addressable Smoke Detector w/Sounder Base m � Q� � A��T. a �, � � �" Door Holder (120VAC) cT� ���� ' ^ � O O � i u� �/1 � �--� � 02 � � � NOTES : � • � � I� � 1. FIRE SYSTEM SHALL BE DESIGNED PER NFPA 72. � I� � O 2. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND I F�� O � ~ ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE � � ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE I ` H � � � � LOCATIONS, SYSTEM DESIGN AND INSTALLATION. �� 3. A�L DETECTORS WITHIN A SING�E UNIT SHALL ACTIVATE li I - Op � O o "` � TOGETHER UPON A LOCAL ALARM WITHIN THE UNIT. I I� \ ' � 4. ALL NEW DEVICES SHALL MATCH EXISTING FIRE ALARM I IN BUILDING. I U 5. EXISTING DEVICES TO REMAIN SHALL BE PROPERLY I z PROTECTED AND COVERED PRIOR TO AND DURING - CONSTRUCTION. � � w 6. EXISTING DEVICE LOCATIONS ARE APPROXIMATED. i4 � � �,�_, Q � � ACTUAL FIELD CONDITIONS MAY VARY FROM ' 4� � ��- � M1 � - LL � UNIT TO UNIT. ! � " � � (E) MAINT. � � oo ° � � � ° � SHOP � a w o Z � � � Z � �----. � ��� U � _ _ �,, z o � ✓LvJ \. � _ � ¢ " 1 00 ......,._.__ '�� �� �. _ U � '-- \� w � Z J w O , �, � G - a i- � P � � � 6Y __ i oo , � � , . � HOTEL , RC�C�,M o ` o P/ , � _� 100 � ASI #1 Q 3-9-12 NOTES : CD 2-23-12 DD PRICING 8-8-11 1. SPRINKLER SYSTEM SHALL BE DESIGNED PER NFPA 13. ISSUED FOR: DATE: 2. EXISTING BUILDING IS FUL�Y SPRINKLERED. CONNECT ALL NEW SPRINKLER HEADS INTO EXISTING SYSTEM PIPING. H OT E L RECALCULATE ALL AFFECTED AREAS. 3. SPRINKLER LOCATIONS AND PIPING ARE SCHEMATIC ONLY AND ��n n /� ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE `�1 4A p PROTECTION CONTRACTOR IS RESPONSIBLE FOR SPRINKLER � SYSTEM DESIGN AND INSTALLATION. � OO FIELD VERIFY SPRINKLER AND ALARM COVERAGE Shaner Life Safety 4. COORDINATE ALL PIPE RUNS WITH STRUCTURAL DRAWINGS. IN AREA. ADJUST/ADD AS NEEDED. BEAM PENETRATIONS SHALL BE COORDINATED WITH STRUCTURAL q'� PO Box �073, Frisco, Cdorado•80443 ENGINEER. SHANERLSOCOMCAST.NET; (970) 409-9082 5. SPRINKLER AND STANDPIPE RISERS SHALL BE SEPARATE. 6. DECKS SHALL BE SPRINKLERED AS SHOWN. SPRINKLER HEADS ON DECKS SHALL BE DRY TYPE. 7. ALL EXISTING SPRINKLER HEADS SHALL BE PROPERLY PROTECTED PRIOR TO AND DURING CONSTRUCTION. � � � � THESE DRAWINGS AND SPECIFICATIONS AND THE 8• EXISTING HEAD LOCATIONS ARE APPROXIMATED. _ _ _ _ _ _ _ _ _ _ _ � L - - - - - - - - - - - - - - - - - - J � - - - - - - ACTUAL FIELD CONDITIONS MAY VARY FROM i�E,as, �ESi�NS AND ARRaN�EMENTs UNIT TO UNIT. ,_ •; :_ _ _,, REPRESENTED THEREBY ARE AND SHALL REMAIN _ _ _ _ _ _ _ _ ,- PROPERTY OF THE ARCHITECT, AND NO PART � � � � � = THEREOF SHALL BE COPIED, DISCLOSED TO I I I I (I ' OTHERS, OR USED IN CONNECTION WITH ANY I ` '� WORK OR PROJECT FOR WHICH THEY HAVE BEEN L - - � � - - — � PREPARED WITHOUT THE WRITTEN CONSENT OF I THE ARCHITECT. VISUAL CONTACT WITH THESE � �,� DRAWINGS OR SPECIFICATIONS SHALL F I R E P R OT E C T I 0 N S Y M B 0 LS � � CONSTITUTE CONCLUSNE EVIDENCE oF I ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN � SPRINKLER HEAD - STANDARD UPRIGHT, CHROME DIMENSIONS oN THESE DRAWINGS SHALL HAVE I PRECEDENCE OVER SCALED DIMENSIONS. � SPRINKLER HEAD - CONCEALED PENDENT, WHITE L — — — — — — — — — — — — — — — — — — CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE — - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - — FOR ALL DIMENSIONS AND CONDITIONS ON THE � SPRINKLER HEAD - RECESSED SIDEWALL, WHITE �os,AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND � SPRINKLER HEAD - DRY SIDEWALL, CHROME CONDITIONS sHOwN BY THESE DRAWINGS. NOTE: SPRINKLER MANUFACTURER AND MODEL SHALL BE CHOSEN BY THE SPRINKLER CONTRACTOR SUBJECT TO APPROVAL BY ARCHITECT AND ENGINEER. COORDINATE 'fYPE AND FINISH WITH INTERIORS. ALL HEADS SHALL BE QUICK RESPONSE, EXCEPT IN ORDINARY HAZARD AREAS. USE SUMMER = 1 ST FLOOR EXTENDED COVERAGE HEADS WHERE APPLICABLE. � FIRST FLOOR pLAN � FIRE PROTECTION PLAN I FPjI .l SCALE: 1/4" = 1 '-0� WWTER z I �� ��= �` .��+Q ��r�, ..� �._��;�,���iGl�..S��.tS` ,.��;��' ;'�r�[�► 1 1 �.�� •�Y�. 1 1 �i� �S23ay ��� ,_.,� • �\ . �,,. ;r� a.': �:`�` `�, � _ , ����, ' _Fj��C�.`��i �►`G�dtA1-'� �\ / � / �' LEGEND� WILDWOOD SYMBOL DEVICE DESCRIPTION . � N 0 T E S . ❑F Manual Pull Station �°�� `��° � }� 1. SPRINKLER SYSTEM SHALL BE DESIGNED PER NFPA 13. O � OO 2• EXISTING BUILDING IS FULLY SPRINKLERED. CONNECT ALL OP Photoelectric Smoke Detector �� N E W S P R I N K L E R H E A D S I N T O E X I S T I N G S Y S T E M P I P I N G. � RECALCULATE ALL AFFECTED AREAS. � Heat Detector (fixed) 3. SPRINKLER LOCATIONS AND PIPING ARE SCHEMATIC ONLY AND � A R E I N T E N D E D T O R E P R E S E N T T H E D E S I G N I N T E N T. F I R E PROTECTION CONTRACTOR IS RESPONSIBLE FOR SPRINKLER � SYSTEM DESIGN AND INSTALLATION. � Horn�Strobe 4. COORDINATE ALL PIPE RUNS WITH STRUCTURAL DRAWINGS. O J . 3 J . I BEAM PENETRATIONS SHALL BE COORDINATED WITH STRUCTURAL ��� Strobe candela s ecified ENGINEER. ' � P � 5. SPRINKLER AND STANDPIPE RISERS SHALL BE SEPARATE. �T� � - � Horn Only W 6. DECKS SHALL BE SPRINKLERED AS SHOWN. SPRINKLER � HEADS ON DECKS SHALL BE DRY TYPE. T � ' 7. ALL EXISTING SPRINKLER HEADS SHALL BE PROPERLY �-�--� Sprinkler Waterflow Switch v � PROTECTED PRIOR TO AND DURING CONSTRUCTION. � " '-"'� ' 8. EXISTING HEAD LOCATIONS ARE APPROXIMATED. � � ACTUAL FIELD CONDITIONS MAY VARY FROM ,.�, Sprinkler Valve Tamper Switch �T� � � � I�'�1 � UNIT TO UNIT. O U ��� � PRINKLER OSB Addressable Smoke Detector w/Sounder Base ` � � � ^ , M--� � � �� °H Door Holder (120VAC) a t� � � � FIRE PROTECTION SYMBOLS � � SPRINKLER HEAD - STANDARD UPRIGHT, CHROME � � � OQ ��� ���E SPRINKLER HEAD - CONCEALED PENDENT, WHITE N OT E S : �� � ' � � �T� O � F.L■+ 1�1 ` I � SPRINKLER HEAD - RECESSED SIDEWALL, WHITE 1. FIRE SYSTEM SHALL BE DESIGNED PER NFPA 72. � OO � SPRINKLER HEAD — DRY SIDEWALL, CHROME 2. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND � � �"� � � ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE � � � ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE � ~J � % -� NOTE: SPRINKLER MANUFACTURER AND MODEL SHALL BE CHOSEN BY THE LOCATIONS, SYSTEM DESIGN AND INSTALLATION. F—� O SPRINKLER CONTRACTOR SUBJECT TO APPROVAL BY ARCHITECT AND r^ � O ENGINEER. COORDINATE '�YPE AND FINISH WITH INTERIORS. ALL HEADS 3. ALL DETECTORS WITHIN A SINGLE UNIT SHALL ACTIVATE � SHALL BE QUICK RESPONSE, EXCEPT IN ORDINARY HAZARD AREAS. USE TOGETHER UPON A LOCAL ALARM WITHIN THE UNIT. v 1 I--I -' EXTENDED COVERAGE HEADS WHERE APPLICABLE. 4. ALL NEW DEVICES SHALL MATCH EXISTING FIRE ALARM � � O � � IN BUILDING. � • � 5. EXISTING DEVICES TO REMAIN SHALL BE PROPERLY � � � 1 PROTECTED AND COVERED PRIOR TO AND DURING � � 1 O � � CONSTRUCTION. �� O O ~ - 6. EXISTING DEVICE LOCATIONS ARE APPROXIMATED. l � �/'� � � ` I ACTUAL FIELD CONDITIONS MAY VARY FROM ^ V e � � �E 1 ���°,.�_� —_ ___ UNIT TO UNIT. � � � �� _� v z � � I N � � / � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � o 0 , � � � � � � � � � � � � � a LL > - v z o � ° N � � � o �"11 N - Q � o Z �. _ _ _ �— 2 � � � wz � . Zo . � J � � Jw �. w � Z � � Q _ � � _� � � _ ��� �T�� � i loo - � KITCHEN USEABLE O O ; H ■ -� AREA - 904.2 S.F. ■ 8 �I� �G G� ■ O � � . . . 0 � � C , � 0 ' �° . ; o � � i��:z. � � �� ASI #1 03-9-12 �e o : b� CD 2-23-12 � ' �'' DD PRICING 8-8-1 1 \ / ADJUST EXISTING SPRINKLER HEAD SPACING p� \ / IN ELEVATOR LOBBY. COOFltDINATE DEMO & r a �?�'�, �" ISSUED FOR: DATE: `O � � DRYWALL REPAIR WITH GENERAL CONTRACTOR. \�� ���'�� ��`�° "�° `' "��'' � ._. , , � ��� :� �-;��_ i T� � ���1 /= ,, , � . � � _ , � � � . __ � _ . , ;, � �P ���� 100 100 � - � '_ , , - _ , �C�� B �1� �_� � � � ' �_� Shaner Life Safety �� �� 200 ' ��� - . - . - - , � ���� - ' � PO Box 1073, Frisco, Colorado 80443 SHANERLSOCOMCAST.NET; (970) 409-9062 _ _ � THESE DRAWINGS AND SPECIFICATIONS AND THE IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN PROPERTY OF THE ARCHITECT, AND NO PART TI! THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY ���'4� .f� � � I � �`"�` l'`a-�-� � � �� � WORK OR PROJECT FOR WHICH THEY HAVE BEEN _ _ 1 FIELD VERIFY SPRINKLER AND ALARM COVERAGE PREPARE� wiTNOUT TNE wRiTrEN coNSENTOF I OO THE ARCHITECT. VISUAL CONTACT WITH THESE IN AREA. ADJUST/ADD AS NEEDED. oRawiN�s oR SPECIFICATIONS sHa,�� CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN I DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. E E T I N � CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE FIELD VERIFY SPRINKLER AND ALARM COVERAGE �oe,AND THIS OFFICE MUST BE NOTIFIED OF ANY IN AREA. ADJUST/ADD AS NEEDED. 1 OO vaRiarioNS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. I 9 ' 2ND FLOOR � SECOND FLOOR PLAN S�MMER = � FIRE PROTECTION PLAN FPl .2 SCALE: 1/4" = 1 '-0" wiNrER z �� ,.; ��, r,� �r+��'' . ����Q;����1��'�;� � �:i�,`�' ;��'�� °a� ���3.�� �:v :� ' �.� ��. � T � I , I � � _.�� _ :� � :" � �.c��`� . `�`��rca�i�a�.-� LEGEND� SYMBOL DEVICE DESCRIPTION N 0 T E S : ❑F Manual Pull Station 1. SPRINKLER SYSTEM SHALL BE DESIGNED PER NFPA 13. 2• EXISTING BUILDING IS FULLY SPRINKLERED. CONNECT ALL OP Photoelectric Smoke Detector NEW SPRINKLER HEADS INTO EXISTING SYSTEM PIPING. RECALCULATE ALL AFFECTED AREAS. � Heat Detector (fixed) 3. SPRINKLER LOCATIONS AND PIPING ARE SCHEMATIC ONLY AND � ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SPRINKLER O SYSTEM DESIGN AND INSTALLATION. Horn/Strobe 4. COORDINATE ALL PIPE RUNS WITH STRUCTURAL DRAWINGS. �� ENG NEER ETRATIONS SHALL BE COORDINATED WITH STRUCTURAL ,�� Strobe (candela specified) � 5. SPRINKLER AND STANDPIPE RISERS SHALL BE SEPARATE. � Horn Only � 6. DECKS SHALL BE SPRINKLERED AS SHOWN. SPRINKLER HEADS ON DECKS SHALL BE DRY TYPE. � 7. ALL EXISTING SPRINKLER HEADS SHALL BE PROPERLY f-�-° Sprinkler Waterflow Switch PROTECTED PRIOR TO AND DURING CONSTRUCTION. �----____ J . 3 J . 7 8. EXISTING HEAD LOCATIONS ARE APPROXIMATED. -�_____ O ACTUAL FIELD CONDITIONS MAY VARY FROM r�, Sprinkler Valve Tamper Switch ___ UNIT TO UNIT. � OSB Addressable Smoke Detector w/Sounder Base � ���� � � W DH Door Holder (120VAC) ...� � ��■ FIRE PROTECTION SYMBOLS � SPRINKLER HEAD - STANDARD UPRIGHT, CHROME I � W � SPRINKLER HEAD - CONCEALED PENDENT, WHITE N 0 T E S : ;'! O ��� V '� ��// � � � SPRINKLER HEAD - RECESSED SIDEWALL, WHITE 1. FIRE SYSTEM SHALL BE DESIGNED PER NFPA 72 ` � � ` ' � � SPRINKLER HEAD - DRY SIDEWALL, CHROME /� 2. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND ~� � � ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE � � ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE � � �O LOCATIONS, SYSTEM DESIGN AND INSTALLATION. // � NOTE: SPRINKLER MANUFACTURER AND MODEL SHALL BE CHOSEN BY THE �E T I L� L E SPRINKLER CONTRACTOR SUBJECT TO APPROVAL BY ARCHITECT AND 3. ALL DETE TORS WITHIN A SIN LE UNIT SHALL A TIVATE S lJ NEW STANDPIPE/SPRINKLER � � OQ ENGINEER. COORDINATE �fYPE AND FINISH WITH INTERIORS. ALL HEADS C G C RISER LOCATION. � � SHALL BE QUICK RESPONSE, EXCEPT IN ORDINARY HAZARD AREAS. USE TOGETHER UPON A LOCAL ALARM WITHIN THE UNIT. � � _ ` O EXTENDED COVERAGE HEADS WHERE APPLICABLE. 4. ALL NEW DEVICES SHALL MATCH EXISTING FIRE ALARM �-��, � OO �M� IN BUILDING. II � Q ,,�� F-�j — � 5. EXISTING DEVICES TO REMAIN SHALL BE PROPERLY 1 � � PROTECTED AND COVERED PRIOR TO AND DURING O � �J CONSTRUCTION. � F-1 � � � o ° 6. EXISTING DEVICE LOCATIONS ARE APPROXIMATED. � � ACTUAL FIELD CONDITIONS MAY VARY FROM UNIT TO UNIT. � � O -�-� • � O � h� � r � I I �� O O h--� � � � � � � � z C.� FFICE o , 2 , z � oo � - � _ N N - � w wm Q o0 � - � LLz o � o - - - - - - - - - N � � � � � � oZ _ � a � - - , _ � w � Z � - wZo � _ J = � M w � ZJw I H __ , � ¢ - � � I o . I� �G G� � z \� � E L � '!_ EXISTING STANDPIPE/SPRINKLER � I RISER LOGATION TO BE RELOCATED. � I I � � - i l __ 3 ���� � "'� '� �� �� ADMIN . ADMIN . � ���ff � �� � , � �,J F F I �E� �,J F F I C E� �ADJUST EXISTING SPRINKLER HEAD SPACING � OO ���� ! IN ELEVATO� LOBBY. COORdINATE DEMO & � � \ DRYWALL REPAIR WITH GENER�AL CONTRACTOR. 100 100 �_,,_-------� � LO B �Y � � � ASI #1 03-9-12 300 CD 2-23-12 DD PRICING 8-8-1 1 ; � _ � ISSUED FOR: DATE: - - i/ ��°�J Shaner Life Safety PO Box 1073, Frisco, Colorado 80443 SHANERLS�COMCAST.NET; (970) 409-9082 ' �.�� I 1"�3.�._.� I. q�l � 0 � � - � � oo THESE DRAWINGS AND SPECIFICATIONS AND THE � IDEAS, DESIGNS AND ARRANGEMENTS ADJUST EXISTING SPRINKLER HEAD SPACING REPRESENTED THEREBY ARE AND SHALL REMAIN IN THIS AREA. COORDINATE DEMO �C PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO DRYWALL REPAIR WITH GENERAL CONTRACTOR. orHERS, OR USED W CONNECTION WITH ANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF � I � I �� OP THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL ? - CONSTITUTE CONCLUSIVE EVIDENCE OF I � I ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE I OO I OO PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB,AND THIS OFFICE MUST BE NOTIRED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. �, � � I 3RD FLOOR FIRE PROTECTION PLAN EXISTI G DECK TO REMAIN - �� �,,; ��� ���� , , ��'�':,���lG t� •�. °�; :� �n _ ���'``�.,�� � � � C7� '� �,F�. 1 � ��9 I�1�� ������t � � �� ��``o� [3 0� ��23.�� 1 m �'. --�-� . � � �s�. -�! • `, FPl .3 SCALE: 1/4" = 1 '-0° . '�^ } ••��v , . -e � . -� '��'l�-... • i�C��` ���dA4L�� J . 3 J . 7 I NEW STANDPIPE/SPRINKLER RISER LOCATION.Q , LEGEND� � : � � �� � � � i�� � � 0 SYMBOL DEVICE DESCRIPTION 4O2 �~ O 0 Manual Pull Station ~� � OP Photoelectric Smoke Detector � � Heat Detector (fixed) � � � Horn/Strobe O . , _ � ,�. Strobe (candela specified) � rT� � ^ W � Horn Only � � � 2 � � � � � Q �--g--� Sprinkler Waterflow Switch rTl � � (Q O U }T, Sprinkler Valve Tamper Switch (� — — — — — — — — — o � � z � E L E�r � �� � � � OSB Addressable Smoke Detector w/Sounder Base � � � � I � � ' 401 � �" Door Holder (120VAC) I " � � OQ ig � � � � �G G� � � � O I � � NOTES: i , � � � � � 1. FIRE SYSTEM SHALL BE DESIGNED PER NFPA 72. ^ ^�I �� � � � n/ �V� � �O 2. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND � � O ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE l ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE � I �� F� � I—� �J � o� � � Q LOCATIONS, SYSTEM DESIGN AND INSTALLATION. 3. A L L D E T E C T O R S W I T H I N A S I N G L E U N I T S H A L L A C T I V A T E > � � -- C— 403 -� �➢. � � � • U TOGETHER UPON A LOCAL ALARM WITHIN THE UNIT. 1 OO Ol OO � ^ ADJUST EXISTING SPRINKLER HEAD SPACING � � 4. ALL NEW DEVICES SHALL MATCH EXISTING FIRE ALARM �/ IN ELEVATOR LOBBY. COOR�INATE DEMO & O � ~ IN BUILDING. �� DRYWALL REPAIR WITH GENEF�AL CONTRACTOR. � �� 5. EXISTING DEVICES TO REMAIN SHALL BE PROPERLY pH` " O � � PROTECTED AND COVERED PRIOR TO AND DURING P � � � � CONSTRUCTION. � � 6 ACTUAL FI�ELDICCOND�ITIONS MAYEVARYR ROMATED. ��� �� ��� UNIT TO UNIT. /� ;��`�� � 400 � DH z N H � � s U Q — LL > U z � o � � � � � � � 0 z _ Q _ v _ _ . s.�"� `1 u, � z 0 J � � Z � = Q w U — � � . � 0 � � Q z a �- \ �'..,, �� _, ���- � I I I I ��°�� � � � I � � � % I I I !- -�� � �� � I I I � �� � - II I I �- � � I � � � � II I I �� � I � J' � I I I I I I \ � � � � � � �u L - - - 1 —� o L — — — — 0 � ���,� � � ; - �' �.� ��� �� ��� ��� �� , ; � � NOTES: 100 �S6 _ _,' � 100 100 i �' 1. SPRINKLER SYSTEM SHALL BE DESIGNED PER NFPA 13. ��,�f���� � � � �� I � � I I O \ 2. EXISTING BUILDING IS FULLY SPRINKLERED. CONNECT ALL I I �� I I NEW SPRINKLER HEADS INTO EXISTING SYSTEM PIPING. i I � �� _I.I RECALCULATE ALL AFFECTED AREAS. �50A j I ASI #� Q3-9-12 3. SPRINKLER LOCATIONS AND PIPING ARE SCHEMATIC ONLY AND � I I OSB CD 2-23-12 ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE I I PROTECTION CONTRACTOR IS RESPONSIBLE FOR SPRINKLER I � � DD PRICING 8-8-1 1 SYSTEM DESIGN AND INSTALLATION. I � ISSUED FOR: DATE: 4. COORDINATE ALL PIPE RUNS WITH STRUCTURAL DRAWINGS. i I I BEAM PENETRATIONS SHALL BE COORDINATED WITH STRUCTURAL ENGINEER. � , '�; i � , ; _ �-� . � � _ _ _ . _ 5. SPRINKLER AND STANDPIPE RISERS SHALL BE SEPARATE. 6. DECKS SHALL BE SPRINKLERED AS SHOWN. SPRINKLER HEADS ON DECKS SHALL BE DRY TYPE. I Sh a n e r Life Safet 7. ALL EXISTING SPRINKLER HEADS SHALL BE PROPERLY I y PROTECTED PRIOR TO AND DURING CONSTRUCTION. _ _ _ PO Box 1073, Frisco, Colorado 80443 8. EXISTING HEAD LOCATIONS ARE APPROXIMATED. sHnNER�socoMCnsr.NEr, (s�o) aos-sos2 ACTUAL FIELD CONDITIONS MAY VARY FROM _ UNIT TO UNIT. I I' I FIRE PROTECTION SYMBOLS THESE DRAWINGS AND SPECIFICATIONSANDTHE IDEAS, DESIGNS AND ARRANGEMENTS 0 SPRINKLER HEAD — STANDARD UPRIGHT, CHROME REPRESENTED THEREBY ARE AND SHALL REMAIN - PROPERTY OF THE ARCHITECT, AND NO PART � SPRINKLER HEAD — CONCEALED PENDENT, WHITE � OTHEROSF OR USEDBIN CONNECTION LOW TH ANOY SPRINKLER HEAD — RECESSED SIDEWALL, WHITE ���>.9r, _ woRK oR PRO�ECT FoR wHicH THEV Ha,vE BEEN � ���,� — -� � PREPARED WITHOUT THE WRITTEN CONSENT OF SPRINKLER HEAD — DRY SIDEWALL, CHROME �;� THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN NOTE: SPRINKLER MANUFACTURER AND MODEL SHALL BE CHOSEN BY THE / � F��U RT I� F L��R P LAI�'°� SUMMER � �innENSioNS oN THESE oRa,ww�s sHA��HavE SPRINKLER CONTRACTOR SUBJECT TO APPROVAL BY ARCHITECT AND � r � PRECEDENCE OVER SCALED DIMENSIONS. ENGINEER. COORDINATE fiYPE AND FINISH WITH INTERIORS. ALL HEADS � CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE SHALL BE QUICK RESPONSE, EXCEPT IN ORDINARY HAZARD AREAS. USE FPl .4 SCALE: 1/4" = 1 '_O" WINTER FOR ALL DIMENSIONS AND CONDITIONS ON THE EXTENDED COVERAGE HEADS WHERE APPLICABLE. �_,�' z VOARIATIONS IS OOM E rHET B�iMOENSIIONSOFAND CONDITIONS SHOWN BY THESE DRAWINGS. SCOPE OF WORK FO � 4TH FLOOR J K L M FIRE PROTECTION PLAN INFILL PROJEC� �� �= �� �,w�: �;�, °,��;:,���i G�.,S+a�.� � � �r�� 7��� � 1 ��o� 3�23.ap� .�;� ,--� . , J� _ ;,� i�,. �`�r���' •••�.,,�.���� `�rG�$d��--`� J . 3 J . 7 � � NEW STANDPIPE/SPRINKLER �I�.��'� RISER LOCATION.Q , LEGEND� �TA I R � SYMBOL DEVICE DESCRIPTION JII 1 O O 502 - � � 0 Manual Pull Station � OP Photoelectric Smoke Detector � � � Heat Detector (fixed) � � Horn/Strobe O . , � ,�. Strobe (candela specified) � W � Horn Only � � �_ _� 2 Q -g- Sprinkler Waterflow Switch T � rTl (Q OV � U }T, Sprinkler Valve Tamper Switch ' _ � � V� � � � � � OSB Addressable Smoke Detector w/Sounder Base - - - - - - - z � rTl � L� N , �� � Q � � _ _ � ) , �--� DH Door Holder (120VAC) -" � � � � OQ E L E�/ � H � � � � � w o 501 — ie � � Q NOTES: �w �� �� � � � 1. FIRE SYSTEM SHALL BE DESIGNED PER NFPA 72. � � � � � , Or � � 2. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND I � � O O ALARM CONTRAC�OREPS RESPONSIBLDEEFOR DEV CE FIRE I � l � /� f� f � l I—� �VI�IIV� LOCATIONS, SYSTEM DESIGN AND INSTALLATION. � 1 O � M--� � l 3. ALL DETECTORS WITHIN A SINGLE UNIT SHALL ACTIVATE �� �I �� � LOS ET . `�� TOGETHER UPON A LOCAL ALARM WITHIN THE UNIT. _ — — 3 � � 4. ALL NEW DEVICES SHALL MATCH EXISTING FIRE ALARM = ' IN BUILDING. 503 1✓O � ADJUST �XISTING SPR,INKLER HEAD SPACING O h--�I IN ELEV�TOR LOBBY. COORDINATE DE'M� & �� O 5. EXISTING DEVICES TO REMAIN SHALL BE PROPERLY � � DRYVIIaLL REPAIR WITH _ GENERAL CONTRACTOR. �^ � � PROTECTED AND COVERED PRIOR TO AND DURING 'I CONSTRUCTION. �� � I �H 6. EXISTING DEVICE LOCATIONS ARE APPROXIMATED. � OP � ACTUAL FIELD CONDITIONS MAY VARY FROM � UNIT TO UNIT. � �� �v� i�,,��(�� i � U 500 z N 'L _ � O � Q - LL > — U z � o " �" �1 [ W O w � � �� N � � 0 z _ Q u — � w � Z U _ ,,, z _.-_-_. J s � Q c, _ . . .. w � z J W 0 0 � a — a � o � o o � o , �� °ee sae , � � , �� , ��o�� i � _ _ _ _ _ _ _ _ = 0 � — � � � �"' L �� � � _ = O O _— i � — „ i � — � � � 5�.� 9�: . � � � � ,' �� � � ��,���� � � lA���� l 1 � � �� � � ==_' _ _ _ _ � �� 0 � 550 o '� NOTES: S �)AREZ 1. SPRINKLER SYSTEM SHALL BE DESIGNED PER NFPA 13. 2. EXISTING BUILDING IS FULLY SPRINKLERED. CONNECT ALL � 550A � NEW SPRINKLER HEADS INTO EXISTING SYSTEM PIPING. � RECALCULATE ALL AFFECTED AREAS. ', OO SB ASI #� Q 3-9-12 3. SPRINKLER LOCATIONS AND PIPING ARE SCHEMATIC ONLY AND CD 2-23-12 ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SPRINKLER DD PRICING 8-8-1 1 SYSTEM DESIGN AND INSTALLATION. i � ISSUED FOR: DATE: 4. COORDINATE ALL PIPE RUNS WITH STRUCTURAL DRAWINGS. / BEAM PENETRATIONS SHALL BE COORDINATED WITH STRUCTURAL � ENGINEER. � _ _ 5. SPRINKLER AND STANDPIPE RISERS SHALL BE SEPARATE. I � -- - 61 i' ii! i''i�l� = i. , 6. DECKS SHALL BE SPRINKLERED AS SHOWN. SPRINKLER � I � HEADS ON DECKS SHALL BE DRY TYPE. S�aner L�fe Safe I 7. ALL EXISTING SPRINKLER HEADS SHALL BE PROPERLY y PROTECTED PRIOR TO AND DURING CONSTRUCTION. _ _ _ PO Box 1073, Frisco, Colorado 80443 8. EXISTING HEAD LOCATIONS ARE APPROXIMATED. sHnNER�socoMCnsr.NEr, (s�o) aos-sos2 ACTUAL FIELD CONDITIONS MAY VARY FROM UNIT TO UNIT. _: � � �,.�, <<�:. ,,_,�, FIRE PROTECTION SYMBOLS THESE DRAWINGS AND SPECIFICATIONS AND THE � SPRINKLER HEAD — STANDARD UPRIGHT, CHROME i�E,as, DESIGNS aN� aR�,aN�EMENTs REPRESENTED THEREBY ARE AND SHALL REMAIN � SPRINKLER HEAD — CONCEALED PENDENT, WHITE PROPERTY oF THE aRCHiTECr, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO � SPRINKLER HEAD — RECESSED SIDEWALL, WHITE OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN � SPRINKLER HEAD — DRY SIDEWALL, CHROME PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF NOTE: SPRINKLER MANUFACTURER AND MODEL SHALL BE CHOSEN BY THE accEPraNCE oF THESE RESTRICTIONS.WRITTEN SPRINKLER CONTRACTOR SUBJECT TO APPROVAL BY ARCHITECT AND �innENSioNS oN THESE oRa,wiN�s sHA��HavE ENGINEER. COORDINATE '�YPE AND FINISH WITH INTERIORS. ALL HEADS PRECE�ENCE OVER SCALED DIMENSIONS. SHALL BE QUICK RESPONSE, EXCEPT IN ORDINARY HAZARD AREAS. USE , coNTRacroRS sHa,��vERiFV,AND BE RESPONSIBLE EXTENDED COVERAGE HEADS WHERE APPLICABLE. r l � k.�l „ p SuMMER = FOR ALL DIMENSIONS AND CONDITIONS ON THE � � � `� �I I I I l� �L�����`'a tl ,_��'�Iy�'tU � JOB,AND THIS OFFICE MUST BE NOTIRED OF ANY VAR ATIONS FROM THE DIMENSIONS AND �� FP� .�J � SCALE: ��4�� — � �-O�� WINTER � CONDI70NS SHOWN BY THESE DRAWINGS. i � �� 5TH FLOOR S C O P E O F WO R K F � � FIRE PROTECTION PLAN J K L M � NFILL PR��IEG� r, �� �._ �`�_ � �a4.'U. ����,. '��''y�',':���1Gj�';�•�� 0'�-��' ;;�.�� ��� ��23.�� �i v • �;� a.:, �:�� ��, - T� � _. °.� i��-,,:,. .� ':�,C,�1`� `��E�fdP�E-� J . 3 J . 7 LEGEND� � SYMBOL DEVICE DESCRIPTION O NEW STANDPIPE/SPRINKLER �� F Manual Pull Station I RISER LOCATION.Q � � OP Photoelectric Smoke Detector =� _ ��� � � O �� Heat Detector (fixed) � Horn/Strobe O . , � ,�. Strobe (candela specified) � ^ � Horn Only I � WALKWAI� TO EAST B U I LD I N G BY OTH E RS (E) EX � .,� ( l � ., �-- -� Sprinkler Waterflow Switch `�/ I ����'� � � T � rTl � ��� � � 1� V W TA I R � O � t�, Sprinkler Valve Tamper Switch , � �� � � 602 �� �"� 0 I�:� - - � M", ►-� � SB Addressable Smoke Detector w/Sounder Base I � � � � � , r--� DH Door Holder (120VAC) � � � 00 ` �� � � ^ O z C _,: � I�'1 NOTES: , N i � � � ( ) � _ � � �4 1. FIRE SYSTEM SHALL BE DESIGNED PER NFPA 72. � � �\� I � � n/ �+-� 2. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND � H O O ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE I c �n � ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE L O� .r � �� � �-1 LOCATIONS, SYSTEM DESIGN AND INSTALLATION. U B � � � I� �G G� � O 3. ALL DETECTORS WITHIN A SINGLE UNIT SHALL ACTIVATE � � � TOGETHER UPON A LOCAL ALARM WITHIN THE UNIT. I � I � � 4. ALL NEW DEVICES SHALL MATCH EXISTING FIRE ALARM I O � IN BUILDING. O P E N TO E LOW i � O p �—+ 5. EXISTING DEVICES TO REMAIN SHALL BE PROPERLY MAI DS � � PROTECTED AND COVERED PRIOR TO AND DURING ^ � � � � CONSTRUCTION. � � ��tl�� �T _ o _ . 3 6. EXISTING DEVICE LOCATIONS ARE APPROXIMATED. , � -, ,_ , - ACTUAL FIELD CONDITIONS MAY VARY FROM 6O3 I` Di ADJUST, EXISTING S , RINKLER HEAD �NACING UNIT TO UNIT. IN ELE�%ATOR LOBBY. COORDINATE �[�E�10 & DRY,4VALL REPAIR WITH GENERAL CON�RACTOR. �_ � U DVI �H O I N i �P � � ° ° LO � �Y � - � ��_� I�� �T m w o � N w � � !� 600 Q � � Z _ � - - � Z FARC lJ S � _ w Z H = � Q �' 0 w � � a � � QZ � � o �o Q ° � 'Y�V W� • GARC IA ' � � _ _ = O o i � �-- — — — --a I NOTES: �- ,�� ii i � _ _ _ _ _ _ � � � , -� i i O O � ii i � , ii ii 1. SPRINKLER SYSTEM SHALL BE DESIGNED PER NFPA 13. D II \\ II I � �� � /'� � / II I I � � � � � � _ J � 2. EXISTING BUILDING IS FULLY SPRINKLERED. CONNECT ALL �_ _ _ � - - - - o N EW SPRINK L ER H EA D S INT O EXI STIN G SY ST EM PIPIN G. � II RECALCULATE ALL AFFECTED AREAS. II II �� �� ° ASI #1 03-9-12 3. SPRINKLER LOCATIONS AND PIPING ARE SCHEMATIC ONLY AND �� ,, '� � '�� -�� CD 2-23-12 ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SPRINKLER Q DD PRICING 8-8-1 1 SYSTEM DESIGN AND INSTALLATION. SB O � �� SB �SSUED FOR: DATE: 4. COORDINATE ALL PIPE RUNS WITH STRUCTURAL DRAWINGS. BEAM PENETRATIONS SHALL BE COORDINATED WITH STRUCTURAL I � II � � _ ENGINEER. O P E N T E LOW I �� I I � ' � — J � JJ � 5. SPRINKLER AND STANDPIPE RISERS SHALL BE SEPARATE. � � � � � 6. DECKS SHALL BE SPRINKLERED AS SHOWN. SPRINKLER � HEADS ON DECKS SHALL BE DRY TYPE. I i �� � 7. ALL EXISTING SPRINKLER HEADS SHALL BE PROPERLY I I � _ = Shaner Life Safety PROTECTED PRIOR TO AND DURING CONSTRUCTION. � I _ _ _ _ 8. EXISTING HEAD LOCATIONS ARE APPROXIMATED. I I PO Box �0�3, Frisco, oo�orado soaa3 ACTUAL FIELD CONDITIONS MAY VARY FROM � � _ - sHnNER�socoMCnsr.NEr, (s�o) aos-soa2 :; ; UNIT TO UNIT. � � � FIRE PROTECTION SYMBOLS THESE DRAW�NGS AND SPECIFICATIONSANDTHE IDEAS, DESIGNS AND ARRANGEMENTS • SPRINKLER HEAD - STANDARD UPRIGHT, CHROME REPRESENTE� rHEREBV a,RE a,N� sHa�� REnnaw Q PROPERTY OF THE ARCHITECT, AND NO PART � THEREOF SHALL BE COPIED, DISCLOSED TO SPRINKLER HEAD — CONCEALED PENDENT, WHITE oTHERS, OR USED IN CONNECTION WITH ANY � SPRINKLER HEAD — RECESSED SIDEWALL, WHITE � WORK OR PROJECT FOR WHICH THEY HAVE BEEN a" PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE � SPRINKLER HEAD — DRY SIDEWALL, CHROME DRAWINGS oR SPECIFICATIONS sHa�� CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE Of THESE RESTRICTIONS.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE NOTE: SPRINKLER MANUFACTURER AND MODEL SHALL BE CHOSEN BY THE PRECEDENCE OVER SCALED �innENSioNS. SPRINKLER CONTRACTOR SUBJECT TO APPROVAL BY ARCHITECT AND CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE ENGINEER. COORDINATE fiYPE AND FINISH WITH INTERIORS. ALL HEADS FOR ALL DIMENSIONS AND CONDITIONS ON THE SHALL BE QUICK RESPONSE, EXCEPT IN ORDINARY HAZARD AREAS. USE �oa,aN�THis oFFicE nnusr aE NoTiFiEO oF ANv VARIATIONS FROM THE DIMENSIONS AND EXTENDED COVERAGE HEADS WHERE APPLICABLE. CONDITIONS SHOWN BY THESE DRAWINGS. / —�� ' � �� IXTH FL�C�R PLAI`�9 s�"'"'�R � � 6TH FLOOR FPI .b SCALE: 1/4�� _ ��-o" WINTER z FIRE PROTECTION PLAN � '` r, �� �, t �.w,� 'L�',l+A H J �,, K L � . � ���'�;:,������,t.�� � � �=��" +s�`��c�s �! ; ��. � � � � � � ��� � � ��a� ���3.�� �� �,� J;� �,` �?�,�` �,, ' ��� ` �: �`��EQFd�l�-���`� J . 3 J . 7 LEGEND� � SYMBOL DEVICE DESCRIPTION NEW STANDPIPE/SPRINKLER O RISER LOCATION.Q ❑F Manual Pull Station �� �, - 1 � � � „ . _ _ I P Photoelectric Smoke Detector � O � Heat Detector (fixed) � � ❑ O� Horn/Strobe ,�. Strobe (candela specified) � � ^ � Horn Only � (E) EXT. � }_ _, Q -g- Sprinkler Waterflow Switch � f71 ��� � � � � ���AIR � U Sprinkler Valve Tamper Switch � � � t�, — � �� � � � . 2 � � � OSB Addressable Smoke Detector w/Sounder Base 702 '" OP ~� � � � Q � � � ' � DH Door Holder (120VAC) � � 4� — — — — — — — — — 0 � � z � W p (N) ' � � NOTES: i � � ELEU � � � � 1. FIRE SYSTEM SHALL BE DESIGNED PER NFPA 72. I � � n/ H ��.� 2. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND �Ol �� o o � � � O O ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE � l ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE I B G G � ��� LOCATIONS, SYSTEM DESIGN AND INSTALLATION. I � � O 3. ALL DETECTORS WITHIN A SINGLE UNIT SHALL ACTIVATE `�\ � � • V TOGETHER UPON A LOCAL ALARM WITHIN THE UNIT. �� I � ^ 4. ALL NEW DEVICES SHALL MATCH EXISTING FIRE ALARM I � M--� O IN BUILDING. �� O O M--I �� (N) MAI DS � � 5. EXISTING DEVICES TO REMAIN SHALL BE PROPERLY \ � ' w � � PROTECTED AND COVERED PRIOR TO AND DURING �� ^ ��� �� I ,` � �J1 CONSTRUCTION. �� �� � � 6. EXISTING DEVICE LOCATIONS ARE APPROXIMATED. O OO ADJUST EXISTING SPRINKLER HEAD SPACING ACTUAL FIELD CONDITIONS MAY VARY FROM �O� UNIT TO UNIT. � IN ELEVAfiOR LOBBY. COORDINATE DEMO & ! DRYWALL REPAIR WITH GENERAL CONTRACTOR. /� i DH / / O v � �P � � LC�� �Y � � a � � � � 7OO � m w , o �' � ` ° � � � � — � DH � � Q � o z _ � �, F�==�-- �, � �_�_ � w � z � �� , � � _ � � �� � , _ _ J � wZ � = Q � — _ — J / � � � �� w I / I I �� � Z � — J � � - - - - - - - � � w � - ��u\— � - - - - - - � -� � � � � Q _ a � — ����� II �� � _ _ �\ /� 1�\ � � ��-1 � I I ^ � ^� —�-, � _ I I � / \ �� � / ��� 1 1 �� �� � ( 1 � �� �� / \ o � � o � �G � o o �� _ � — _ - - - - - - - - - - - - -,��, � � �� �� , � � � �� �� — � r - - - ___— � — - - - � — � i —� _ _ � I I �� NOTES: _- - - _ �- - - - - �L - - - 1. SPRINKLER SYSTEM SHALL BE DESIGNED PER NFPA 13. � � � OSB � 2. EXISTING BUILDING IS FULLY SPRINKLERED. CONNECT ALL NEW SPRINKLER HEADS INTO EXISTING SYSTEM PIPING. RECALCULATE ALL AFFECTED AREAS. ASI #1 03-9-12 3. SPRINKLER LOCATIONS AND PIPING ARE SCHEMATIC ONLY AND O O CD 2-23-12 ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SPRINKLER DD PRICING 8-8-1 1 SYSTEM DESIGN AND INSTALLATION. � �SSUED FOR: DATE: 4. COORDINATE ALL PIPE RUNS WITH STRUCTURAL DRAWINGS. / BEAM PENETRATIONS SHALL BE COORDINATED WITH STRUCTURAL ENGINEER. � � � � 5. SPRINKLER AND STANDPIPE RISERS SHALL BE SEPARATE. \ 6. DECKS SHALL BE SPRINKLERED AS SHOWN. SPRINKLER � HEADS ON DECKS SHALL BE DRY TYPE. � I n O � � ���� Shaner Life Safety 7. A L L E X I S T I N G S P R I N K L E R H E A D S S H A L L B E P R O P E R L Y I PROTECTED PRIOR TO AND DURING CONSTRUCTION. � , , - - . - . . - - . -;. , i i , ;, ', , �, , _ _._.. _ __ — _ . - ` PO Box 1073. Frisco. Colorado 80443 8. EXISTING HEAD LOCATIONS ARE APPROXIMATED. � � � � Q SHANERLSOCOMCAST.NET; (s�o) aos-soa2 ACTUAL FIELD CONDITIONS MAY VARY FROM � UNIT TO UNIT. � / / FIRE PROTECTION SYMBOLS THESE DRAWINGS AND SPECIFICATIONSANDTHE IDEAS, DESIGNS AND ARRANGEMENTS �. SPRINKLER HEAD – STANDARD UPRIGHT, CHROME REPRESENTED THEREBY ARE AND SHALL REMAIN PROPERTY OF THE ARCHITECT, AND NO PART � SPRINKLER HEAD – CONCEALED PENDENT, WHITE THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY � SPRINKLER HEAD – RECESSED SIDEWALL, WHITE WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF � SPRINKLER HEAD – DRY SIDEWALL, CHROME THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE Of THESE RESTRICTIONS.WRITTEN NOTE: SPRINKLER MANUFACTURER AND MODEL SHALL BE CHOSEN BY THE DIMENSIONS oN THESE DRAWINGS SHALL HAVE SPRINKLER CONTRACTOR SUBJECT TO APPROVAL BY ARCHITECT AND PRECEDENCE OVER SCALED DIMENSIONS. ENGINEER. COORDINATE fiYPE AND FINISH WITH INTERIORS. ALL HEADS CONTRACTORS SHALL VERIFY,AND BE RESPONSIBLE SHALL BE QUICK RESPONSE, EXCEPT IN ORDINARY HAZARD AREAS. USE ' ^ SUMMER = FOR ALL DIMENSIONS AND CONDITIONS ON THE EXTENDED COVERAGE HEADS WHERE APPLICABLE. S EV E N T H F LO`J R P LAN �oa,aN�THis oFFicE nnusr aE NoTiFiEO oF ANv � � �/ VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. \FPl .7 SCALE: 1/4" = 1 '_0" wiNrER z � - —� , _ .� 7TH FLOOR FIRE PROTECTION PLAN � , r, ^'= P E F R K t� �:�w:��;���� SCO O WO �� J K � a�� ��+s, �l� �;rs��� � � M o.:� ; -�.a F O R I N F I L L P ROJ E �� �.. �F� ���3��r.��� ��� �'��,�-:......���`� ��UtdAL'� • J . 3 J . 7 � LEGEND� � SYMBOL DEVICE DESCRIPTION � _ � O ❑F Manual Pull Station �� � OP Photoelectric Smoke Detector � � Heat Detector (fixed) � � Horn/Strobe I O . , � ,�. Strobe (candela specified) � W � Horn Only � � � ,. �---g--�* Sprinkler Waterflow Switch L r71 � r^l O V t�, Sprinkler Valve Tamper Switch `��.� � � � � �� � � OSB Addressable Smoke Detector w/Sounder Base � � � � � � � DH Door Holder (120VAC) � � O'0 � � � ^ O � � NOTES. � � � � 1. FIRE SYSTEM SHALL BE DESIGNED PER NFPA 72. � � 2. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND � � O O ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE l ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE � � h—I LOCATIONS, SYSTEM DESIGN AND INSTALLATION. � O 3. ALL DETECTORS WITHIN A SINGLE UNIT SHALL ACTIVATE � � � TOGETHER UPON A LOCAL ALARM WITHIN THE UNIT. � ^ 4. ALL NEW DEVICES SHALL MATCH EXISTING FIRE ALARM _ I� � O IN BUILDING. 3 M--I �� O 0 5. EXISTING DEVICES TO REMAIN SHALL BE PROPERLY � � PROTECTED AND COVERED PRIOR TO AND DURING � � � � CONSTRUCTION. 6. EXISTING DEVICE LOCATIONS ARE APPROXIMATED. ACTUAL FIELD CONDITIONS MAY VARY FROM UNIT TO UNIT. 1 � U — — — — — — � z � � I � o � � � �� �� � � i ��°�� ��°�� � ° � __ � Q � � ��� �� w � i - LL Q � _ _ �� , o m � � �� �' I I —� `� � � `� � � oZ � / II � � Q � _ _ - - � � w w — � �.—�I U F I � `1 z - - Z � I \ / / Z Q M \ ~ � �� �\ � � /� II � , � w � za � I / '—�r�-.\ I I �� �, �SB � Q �, � � � � \ � � �� �. � - - - - - - — - - - . -� �1� i _ _ . :� ; . - - - - - - - � i � � i i �_ � � �sB � � I J - - — - - - - .- - - - - - — - - - - - - - - - - -- � � I�� - - - �� � �\ IIII � � I NOTES: � � � i i ' � �� i r - - - - li �� 1. SPRINKLER SYSTEM SHALL BE DESIGNED PER NFPA 13. � � — � �L� _ — � � —i- - 2. EXISTING BUILDING IS FULLY SPRINKLERED. CONNECT ALL � I / � I I II /� \\ I I � NEW SPRINKLER HEADS INTO EXISTING SYSTEM PIPING. � j I l I I I I I / � J I�'�� RECALCULATE ALL AFFECTED AREAS. � I � I I u- � i��� ASI #� 0 3-9-12 3. SPRINKLER LOCATIONS AND PIPING ARE SCHEMATIC ONLY AND OSB I /� I � ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE � I � � � CD 2-23-12 PROTECTION CONTRACTOR IS RESPONSIBLE FOR SPRINKLER I � � — ���� DD PRICING 8-8-11 SYSTEM DESIGN AND INSTALLATION. � L - -- ��� I �' �SSUED FOR: DATE: 4. C O O R D I N A T E A L L P I P E R U N S W I T H S T R U C T U R A L D R A W I N G S. I I� i I _ _ _ _ _ _ _ _ � _ BEAM PENETRATIONS SHALL BE COORDINATED WITH STRUCTURAL — � � II I I i ' � � ENGINEER. � II I � 1 5. SPRINKLER AND STANDPIPE RISERS SHALL BE SEPARATE. �\ I I I I �� �� � _ _ � 6. DECKS SHALL BE SPRINKLERED AS SHOWN. SPRINKLER —' � 'I I-, 1 II i I I HEADS ON DECKS SHALL BE DRY TYPE. � �` � � ShCII1 r Lif fet �� 7. ALL EXISTING SPRINKLER HEADS SHALL BE PROPERLY � e e Sa y PROTECTED PRIOR TO AND DURING CONSTRUCTION. _ _ _ _ PO Box 1073, Frisco, Colorado 80443 8. EXISTING HEAD LOCATIONS ARE APPROXIMATED. sHnNER�socoMCnsr.NEr, (s�o) aos-soa2 ACTUAL FIELD CONDITIONS MAY VARY FROM UNIT TO UNIT. FIRE PROTECTION SYMBOLS THESE DRAWINGS AND SPECIFICATIONS AND THE � SPRINKLER HEAD — STANDARD UPRIGHT, CHROME I i�Eas, DESIGNS AND aRRaN�EnnENTs REPRESENTED THEREBY ARE AND SHALL REMAIN � SPRINKLER HEAD — CONCEALED PENDENT, WHITE PROPERTY oF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO � SPRINKLER HEAD — RECESSED SIDEWALL, WHITE OTHERS, OR USED IN CONNECTION W�TH ANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN � SPRINKLER HEAD — DRY SIDEWALL, CHROME PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE SUMMER = DRAWINGS OR SPEQFICATIONS SHALL E I G H T H F LO O R P LA N ~ CONSTITUTE CONCLUSIVE EVIDENCE oF NOTE: SPRINKLER MANUFACTURER AND MODEL SHALL BE CHOSEN BY THE � � ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN SPRINKLER CONTRACTOR SUBJECT TO APPROVAL BY ARCHITECT AND Fp� .g �� _ � �� I wINTER DIMENSIONS oN THESE �R,nwiN�s sHa,��HAVE ENGINEER. COORDINATE 'fYPE AND FINISH WITH INTERIORS. ALL HEADS SCALE: 1/4 — 1 -0 z PRECEDENCE OVER SCALED DIMENSIONS. SHALL BE QUICK RESPONSE, EXCEPT IN ORDINARY HAZARD AREAS. USE I coNTRa,cTORS sHA��vERiFV,ANO BE RESPONSia�E EXTENDED COVERAGE HEADS WHERE APPLICABLE. FoR a�� �innENSioNS aN�coN�irioNS oN rHE JOB,AND THIS OFFICE MUST BE NOTIRED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SCO PE O F WO RK 8TH FLOOR FIRE PROTECTION PLAN J K FOR INFILL PROJECT L -��: �n, •:"�,,.�Q�i���I'' =,�`�'e�����r�';�. � *,J: ''" ;T`r'`���yy; 4��� , �:.�a �'�233� �i 4 �, ,.;� �.` _ ��` ��' 1 .., _, , ,, � � Y�'��''•d.. • '����� �E{��d�l�.�, J . 3 J . 7 LEGEND� � SYMBOL DEVICE DESCRIPTION O ❑F Manual Pull Station �� II _ ,. � � OP Photoelectric Smoke Detector � � Heat Detector (fixed) � � Horn/Strobe � O ,�. Strobe (candela specified) � � ^ � Horn Only � � ,_ _, � -g- Sprinkler Waterflow Switch r71 � r^l O V t�, Sprinkler Valve Tamper Switch �_ � � � _ � �� � � OSB Addressable Smoke Detector w/Sounder Base - � � W Q � � � DH Door Holder (120VAC) � � � � � � � W � � Q NOTES. � � � � 1. FIRE SYSTEM SHALL BE DESIGNED PER NFPA 72. I � � 2. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND � � O O ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE l ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE � h—I LOCATIONS, SYSTEM DESIGN AND INSTALLATION. `\ - � � O 3. ALL DETECTORS WITHIN A SINGLE UNIT SHALL ACTIVATE NOTE: PROVIDE CONTROL RELAYS FOR ELEVATOR PRIMARY / . r 1 TOGETHER UPON A LOCAL ALARM WITHIN THE UNIT. � O O AND SECONDARY RECALL, ELEVATOR SHUNT TRIP AND HAT /�-1 � • �•J � LIGHT INTERFACE WITH FACP. � � 4. A L L N E W D E V I C E S S H A L L M A T C H E X I S T I N G F I R E A L A R M � O IN BUILDING. �� O O M--I 5. EXISTING DEVICES TO REMAIN SHALL BE PROPERLY � � � PROTECTED AND COVERED PRIOR TO AND DURING \. ! .. 3 � � � � CONSTRUCTION. 6. EXISTING DEVICE LOCATIONS ARE APPROXIMATED. � O ACTUAL FIELD CONDITIONS MAY VARY FROM ' P UNIT TO UNIT. J _- I � U Z � � � o � u O � " 'z i U m o 0 N N � `� � � Z (E) ELEV. Q � � _ - � � I�� II� E � �� - � � = w � � _ � � ' �� � � � 1 Z � = Q w � Z � w 900 � a - n � o \�� , , , � � ; � NOTES: - 1. SPRINKLER SYSTEM SHALL BE DESIGNED PER NFPA 13. 2. EXISTING BUILDING IS FULLY SPRINKLERED. CONNECT ALL NEW SPRINKLER HEADS INTO EXISTING SYSTEM PIPING. RECALCULATE ALL AFFECTED AREAS. ASI #1 � 3-9-12 3. SPRINKLER LOCATIONS AND PIPING ARE SCHEMATIC ONLY AND CD 2-23-12 ARE INTENDED TO REPRESENT THE DESIGN INTENT. FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SPRINKLER DD PRICING 8-8-1 1 SYSTEM DESIGN AND INSTALLATION. �SSUED FOR: DATE: 4. COORDINATE ALL PIPE RUNS WITH STRUCTURAL DRAWINGS. ' BEAM PENETRATIONS SHALL BE COORDINATED WITH STRUCTURAL ENGINEER. 5. SPRINKLER AND STANDPIPE RISERS SHALL BE SEPARATE. 6. DECKS SHALL BE SPRINKLERED AS SHOWN. SPRINKLER HEADS ON DECKS SHALL BE DRY TYPE. SI laner L�fe Safel 7. ALL EXISTING SPRINKLER HEADS SHALL BE PROPERLY y PROTECTED PRIOR TO AND DURING CONSTRUCTION. i - - - - PO Box 1073, Frisco, Colorado 80443 8. EXISTING HEAD LOCATIONS ARE APPROXIMATED. sHnNER�socoMCnsr.NEr, (s�o) aos-soa2 ACTUAL FIELD CONDITIONS MAY VARY FROM UNIT TO UNIT. I FIRE PROTECTION SYMBOLS I THESE DRAWINGS AND SPECIFICATIONSANDTHE IDEAS, DESIGNS AND ARRANGEMENTS • SPRINKLER HEAD — STANDARD UPRIGHT, CHROME REPRESENTED THEREBY ARE AND SHALL REMAIN Q PROPERTY OF THE ARCHITECT, AND NO PART � THEREOF SHALL BE COPIED, DISCLOSED TO SPRINKLER HEAD — CONCEALED PENDENT, WHITE OTHERS, OR USED IN CONNECTION W�TH ANY � WORK OR PROJECT FOR WHICH THEY HAVE BEEN SPRINKLER HEAD — RECESSED SIDEWALL, WHITE PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE � SPRINKLER HEAD — DRY SIDEWALL, CHROME �—� = DRAWINGS oR SPEQFICATIONS SHALL � 1 �I �p����� ������� �}� �p� � SUMMER � CONSTITUTE CONCWSIVE EVIDENCE OF � � U�`L ACCEPTANCE OF THESE RESTRICTIONS.WRITTEN DIMENSIONS ON THESE DRAWWGS SHALL HAVE NOTE: SPRINKLER MANUFACTURER AND MODEL SHALL BE CHOSEN BY THE '�, FPl .9 ;' SCALE: 1/4" = 1 '_O" wINTER PRECEDENCE OVER SCALED DIMENSIONS. SPRINKLER CONTRACTOR SUBJECT TO APPROVAL BY ARCHITECT AND I � � ;' Z CONTRACTORS SHALLVERIFY,ANO BE RESPONSia�E ENGINEER. COORDINATE fiYPE AND FINISH WITH INTERIORS. ALL HEADS J -- '" FOR ALL DIMENSIONS AND CONDITIONS ON THE SHALL BE QUICK RESPONSE, EXCEPT IN ORDINARY HAZARD AREAS. USE �oB,ANO THis oFFicE nnusT BE NoTiFiE�oF aNv EXTENDED COVERAGE HEADS WHERE APPLICABLE. vaRi,aTioNS FROM THE �innENSioNS AND CONDITIONS SHOWN BY THESE DRAWINGS. S C O P E O F W O R K 9TH FLOOR FIRE PROTECTION PLAN FOR INFILL PROJECT r, � �� �. i " w�. ���� ' ,,r�"'�;������ii�; �€�a � .c'��C`"F *J'�.�" $s`"�� S� ��� � o c�a;:� ���3.�r �; �.� �"•;'� �`;, �?:�' ��' 1 � ; -• '.;.•,��i • �`���CB�'d�4k--����.