HomeMy WebLinkAboutB12-0308 ASBESTOS TEST REPORTHERRON® Enterprises USA, Inc.
Phone (303) 763 9639
Fax (303) 763 9686
E-Mail Lennie.Herron@comcast.net
Hazardous Materials*Mold*Asbestos*Lead Paint Website www.HERRON-Enterprises.com
Environmental Services*Industrial Hygienists 7261 W. Hampden Ave., Lakewood, Colorado 80227-5305
HERRON® Project No. 0710126
Limited Asbestos Building Inspection
Page No. - 1 July 12, 2012
July 12, 2012
SRE Builders/Ms. Sarah Wyscarver
HERRON® Project No.: 0710126
Job No.: Verbal
Location: ‘Single Family Residential Dwelling’, 1st Floor Bathroom Walls and Floor, Unit #2, 1817 Meadow Ridge
Rd., Vail, CO 81657
Date(s) of Service: July 10-12, 2012
Services Requested: Environmental Consultation/Limited Asbestos Building Inspection
Per your request, and under the guidelines defined, HERRON® Enterprises USA, Inc. (HERRON®) has concluded the
Environmental Consultation/Comprehensive Asbestos Building Inspection at the aforementioned property.
Local, state and/or federal regulations, including but not limited to AQCC Regulation 8 (State), 29 CFR 1926.1101
(OSHA), 40 CFR Part 61 EPA (NESHAP), and 40 CFR 763 EPA (AHERA) may require a comprehensive asbestos
inspection prior to a renovation or demolition. This inspection requires an AHERA and State certified asbestos building
inspector identifying and sampling any friable and non-friable asbestos containing materials which could be affected by the
activity.
HERRON® was contracted by the Client, to perform:
1. ‘Single Family Residential Dwelling’, 1st Floor Bathroom Walls and Floor, Unit #2, 1817 Meadow Ridge Rd.,
Vail, CO 81657
a. Limited to locations of the submitted instructions and/or renovation/demolition plans, only. Any
locations/materials not specifically identified are assumed to be a Regulated Asbestos Containing
Material, and should be inspected prior to any activity which may disturb the materials;
i. Refer to materials identified in the report;
1. White Drywall/Joint Compound Walls, throughout Bathroom
2. White 4x4” Ceramic Tile and Adhesive, throughout Bathroom Shower Walls
3. White 3x6” Ceramic Tile and Adhesive, throughout Bathroom Floor
a. Ceiling is excluded from the inspection
b. Non-destructive bulk sampling;
c. 1 Day Turnaround PLM Analyses;
d. It was expressly advised that although this is a Limited Asbestos Building Inspection, it is a limited
inspection which is designed to indicate the presence of Asbestos Containing Materials in the Building(s),
and under normal the guidelines defined, specific samples and locations have been instructed and
authorized by the Client. Although some materials may indicate that Asbestos is not present in this
report, and under the protocol of limited sampling whereas not ‘all’ suspect materials were sampled,
under local, state and/or federal regulations, including but not limited to AQCC Regulation 8 and OSHA
29 CFR 1926.1101, a certain protocol for sampling, number of samples obtained, and assessment is
required.
HERRON® was subsequently contracted by the Client, to perform:
1. Not applicable.
HERRON® Enterprises USA, Inc.
Phone (303) 763 9639
Fax (303) 763 9686
E-Mail Lennie.Herron@comcast.net
Hazardous Materials*Mold*Asbestos*Lead Paint Website www.HERRON-Enterprises.com
Environmental Services*Industrial Hygienists 7261 W. Hampden Ave., Lakewood, Colorado 80227-5305
HERRON® Project No. 0710126
Limited Asbestos Building Inspection
Page No. - 2 July 12, 2012
Thank you for the opportunity to be of service. Should you have any questions or comments regarding this report, please do
not hesitate to call HERRON® Enterprises USA, Inc.
Sincerely,
Julie Lucas
Administrative Assistant
HERRON® Enterprises USA, Inc.
Certified Asbestos Building Inspector(s): Julie Lucas (Administrative Assistant), and Dillon D. Carson
Assumptions, and Limitations
This Environmental Consultation is applicable in whole, not in part, to the entire contents of the document.
HERRON® and this Environmental Consultation make no representation or assumptions as to past and/or future
conditions/occurrences of the specific area(s) inspected.
The results, conclusions and/or recommendations expressed in this Environmental Consultation are based solely on the
conditions which were observed at the time of this Environmental Consultation.
HERRON®’s inspection incorporated non-destructive sampling techniques and visual inspections in areas which were
visible/accessible. Conditions and/or materials which were not inspected and/or commented on may very well differ from
those which were inspected and/or commented on.
HERRON® selected sample locations and frequency of sampling based on observations, your requirements and/or the
assumption that like materials in the same area are homogeneous.
HERRON® has specifically designed this Environmental Consultation for Client use in the location and identity of
Asbestos Containing Material (ACM), and under no circumstances is this Environmental Consultation to be copied,
used as a bidding tool and/or used for the development of an Asbestos Abatement Specification document without the
express written permission of an executive officer of HERRON®.
HERRON® is not responsible/liable for any opinions, conclusions and/or recommendations as provided by others based on
any means presented in this Environmental Consultation.
With use of Environmental Consultation, and/or use of any services offered by HERRON®, Client(s) agrees that HERRON®
has been given the authority by the Owner(s) of a property to enter the aforementioned premises, perform the services, utilize
any and all floor plans, blue prints, etc., and agrees to indemnify, hold harmless, and defend HERRON®, its Officers,
Employees, Assigns, etc. for any and all claims, costs or damages that may result from services contracted, etc.
HERRON® Enterprises USA, Inc.
Phone (303) 763 9639
Fax (303) 763 9686
E-Mail Lennie.Herron@comcast.net
Hazardous Materials*Mold*Asbestos*Lead Paint Website www.HERRON-Enterprises.com
Environmental Services*Industrial Hygienists 7261 W. Hampden Ave., Lakewood, Colorado 80227-5305
HERRON® Project No. 0710126
Limited Asbestos Building Inspection
Page No. - 3 July 12, 2012
Recommendations
The Client has advised that ‘Single Family Residential Dwelling’, 1st Floor Bathroom, Unit #2, 1817 Meadow Ridge
Rd., Vail, CO 81657 is a renovation.
As Regulated Asbestos Containing Materials were not discovered during this inspection, further action is not required.
Should a renovation or demolition occur which would affect materials that were not homogeneous to the materials which
were inspected and determined negative for Asbestos, HERRON® would recommend as a minimum Plan of Action:
1. Comprehensive Asbestos Building Inspection: a continuous process in areas which may not have been accessible,
or for materials which may have been concealed in previous inspections, may be required, i.e., review and usage of
previous Asbestos Inspection(s), identification of suspect materials, friable and non-friable, approximate quantities
(ACM), discovery sampling in areas which will be affected by the renovation/demolition in order to determine the
presence of Asbestos Containing Materials (ACM), etc.
Conclusion
Based on the information generated by this report, we conclude that the aforementioned property does not contain Regulated
Asbestos Containing Material(s) (RACM), in accordance with local, state, and/or federal regulations.
In order to comply with local, state, and/or federal regulations, the following RACM, or assumed RACM will have to be
removed if they will be affected by the renovation:
1. None detected.
AHERA RATINGS
Rating Surfacing Material TSI Miscellaneous Material
1 Damaged or Significantly Damaged
2 Damaged
3 Significantly Damaged
4 Damaged or Significantly Damaged
5 Good Condition with Potential for
Damage
Good Condition with Potential for
Damage
Good Condition with Potential for
Damage
6 Good Condition with Potential for
Significant Damage
Good Condition with Potential for
Significant Damage
Good Condition with Potential for
Significant Damage
7 Good Condition with Low Potential Good Condition with Low Potential Good Condition with Low Potential
Asbestos
Forms
C = Chrysotile
A = Amosite
TA = Temolite-
Actinolite
Although a material may have been determined to contain <=1.0% Asbestos, such as the composition of drywall/joint
compound (when the joint compound does not cover the entire surface), traces of asbestos in surfacing materials, thermal
system insulation materials, or miscellaneous materials, etc, which is not considered Regulated Asbestos Containing
Materials by NESHAPS, EPA (AHERA), or the State of Colorado, may still be regulated by OSHA. OSHA regulations
may apply during potential disturbance activities, and the inspection document will serve as a Hazard Communication and
should be reviewed during an activity such as a renovation or demolition, to ensure that an exposure does not occur. The
Maximum Allowable Asbestos Level (MAAL) may not be exceeded at ‘any’ time in accordance with local, state, and/or
federal regulations, including but not limited to AQCC Regulation 8 (State), 29 CFR 1926.1101 (OSHA), 40 CFR Part 61
HERRON® Enterprises USA, Inc.
Phone (303) 763 9639
Fax (303) 763 9686
E-Mail Lennie.Herron@comcast.net
Hazardous Materials*Mold*Asbestos*Lead Paint Website www.HERRON-Enterprises.com
Environmental Services*Industrial Hygienists 7261 W. Hampden Ave., Lakewood, Colorado 80227-5305
HERRON® Project No. 0710126
Limited Asbestos Building Inspection
Page No. - 4 July 12, 2012
EPA (NESHAP), and 40 CFR 763 EPA (AHERA).
This document serves as a certified notification to the owner/operator of the facility and the demolition contractor that any
asbestos-containing material allowed to stay in the facility must remain non-friable during demolition.
All building material field information concerning sampling protocols, locations, assessments, etc. is available in our files for
Client use should the need arise.
Suspect materials which were sampled and determined to contain <=1.0% Asbestos (refer to Attachments), by PLM and/or
PLM Point Count analysis are:
White Drywall/Joint Compound Walls, Surfacing Material (S), <1,000 SF, Good Condition (Current Condition), Non-
Friable, throughout Bathroom, 3 Sample(s),
071012-1A, S Wall, 5’ from E Wall, 5’ from Floor
071012-1B, E Wall, 2’ from S Wall, 5’ from Floor
071012-1C, SE Corner, 5’ from Floor
White 4x4” Ceramic Tile and Adhesive, Miscellaneous Material (M), <160 SF, Good Condition (Current Condition),
Non-Friable, throughout Bathroom Shower Walls, 1 Sample(s),
071012-2A, E Wall, 4’ from N Wall, 5’ from Floor
White 3x6” Ceramic Tile and Adhesive, Miscellaneous Material (M), <160 SF, Good Condition (Current Condition),
Non-Friable, throughout Bathroom Floor, 1 Sample(s),
071012-3A, at Door
Suspect materials which were not within the Scope of Work at the time of the inspection were:
1. ‘All’ EPA suspect Materials not requested:
a. Limited to locations of the submitted instructions and/or renovation/demolition plans, only. Any
locations/materials not specifically identified are assumed to be a Regulated Asbestos Containing
Material, and should be inspected prior to any activity which may disturb the materials;
i. Refer to materials identified in the report;
1. White Drywall/Joint Compound Walls, throughout Bathroom
2. White 4x4” Ceramic Tile and Adhesive, throughout Bathroom Shower Walls
3. White 3x6” Ceramic Tile and Adhesive, throughout Bathroom Floor
a. Ceiling is excluded from the inspection
2. ‘Any’ confirmed or suspect ACM which may have been concealed at the time of the inspection.
3. During a normal inspection, and more specifically when non-destructive sampling techniques are employed, it is not
within the scope of the inspection to remove surface materials to inspect the structures and/or materials which may be
under the surface, i.e., within or under concealed areas such as under carpet, under sub-floors, within chases, walls,
crawlspaces, tunnels, etc., to remove suspect Asbestos Containing Material(s), to move and/or sample electrical
wiring which has not been 'locked out', etc. All said areas are to be assumed as containing >1.0% Asbestos, until
such a time that these areas are made accessible, and/or rendered safe so that sampling can be performed.
4. HERRON® recommends extreme caution during a renovation or demolition of these areas in the event that an area
which was not suspect, visible, accessible and/or specified during the inspection, is discovered to contain or is
suspected of containing an Asbestos Containing Material (ACM). Under local, state and/or federal regulations,
should such an event occur, the Client and or Contractor is required to cease operations which may effect this (these)
HERRON® Enterprises USA, Inc.
Phone (303) 763 9639
Fax (303) 763 9686
E-Mail Lennie.Herron@comcast.net
Hazardous Materials*Mold*Asbestos*Lead Paint Website www.HERRON-Enterprises.com
Environmental Services*Industrial Hygienists 7261 W. Hampden Ave., Lakewood, Colorado 80227-5305
HERRON® Project No. 0710126
Limited Asbestos Building Inspection
Page No. - 5 July 12, 2012
material(s) until an inspection is concluded and a determination is made by an AHERA and State Certified Asbestos
Building Inspector.
5. It was expressly advised that although this is a Limited Asbestos Building Inspection, it is comprehensive to the
aforementioned materials. Only materials impacted requiring response actions have been instructed and
authorized by the Client. Under the protocol of limited sampling whereas not ‘all’ suspect materials outside of the
response action areas were sampled, under local, state and/or federal regulations, including but not limited to
AQCC Regulation 8 and OSHA 29 CFR 1926.1101, a certain protocol for sampling, number of samples obtained,
and assessment is required.
6. Disturbance of these areas could create a potential health hazard.
Suspect materials which were visually inspected and determined to be Non-ACM materials at the time of the inspection were:
Fiberglass
Wood
Glass
Metal
Plastic
Concrete
Etc.
Inspection Methodology:
HERRON® selected sample locations and frequency of sampling based on observations, Client requirements and/or
the assumption that like materials in the same area are homogeneous in accordance with EPA Publication EPA 560 /
5-85 - 030a ‘Asbestos in Buildings: Simplified Sampling Scheme’.
Sample locations and frequency of sampling of Walls and Ceilings are based on EPA 9/30/94 EPA Sampling Bulletin -
ASBESTOS SAMPLING BULLETIN September 30, 1994 - Supplementary Guidance on Bulk Sample Collection and
Analysis. Section V of this guidance bulletin offers a suggested strategy for distinguishing between joint compound
found at joints in wallboard systems or when the material was applied as a skim coat; i.e., for determining whether “joint
compound” has been applied as a “skim coat” over a wall surface (as referred to in the NESHAP Jan. 5, 1994 FR notice.).
HERRON® Enterprises USA, Inc.
Phone (303) 763 9639
Fax (303) 763 9686
E-Mail Lennie.Herron@comcast.net
Hazardous Materials*Mold*Asbestos*Lead Paint Website www.HERRON-Enterprises.com
Environmental Services*Industrial Hygienists 7261 W. Hampden Ave., Lakewood, Colorado 80227-5305
HERRON® Project No. 0710126
Limited Asbestos Building Inspection
Page No. - 6 July 12, 2012
1A
1B
1C
2A
3A
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2012
T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc
Laboratory Code:RES
Subcontract Number:NA
Laboratory Report:RES 239860-1
Project # / P.O. #0710126
Project Description:
Lennie Herron
RES 239860-1
Sincerely,
Anita Grigg Robert R. Workman Jr.
Bethany Nichols Anya Angst
July 12, 2012
Analyst(s): _________________________
Paul D. LoScalzo Wenlong Liu
Michael Scales Adam Humphreys
is the job number assigned to this study. This report is considered highly confidential
andthesolepropertyofthecustomer.ReservoirsEnvironmental,Inc.willnotdiscussanypartofthisstudy
withpersonnelotherthanthoseoftheclient.Theresultsdescribedinthisreportonlyapplytothesamples
analyzed.ThisreportmustnotbeusedtoclaimendorsementofproductsoranalyticalresultsbyNVLAPor
anyagencyoftheU.S.Government.Thisreportshallnotbereproducedexceptinfull,withoutwritten
approvalfromReservoirsEnvironmental,Inc.Sampleswillbedisposedofaftersixtydaysunlesslonger
storage is requested. If you have any questions about this report, please feel free to call 303-964-1986.
Jeanne Spencer
President
Dear Customer,
ReservoirsEnvironmental,Inc.isananalyticallaboratoryaccreditedfortheanalysisofIndustrialHygiene
andEnvironmentalmatricesbytheNationalVoluntaryLaboratoryAccreditationProgram(NVLAP),Lab
Code101896-0forTransmissionElectronMicroscopy(TEM)andPolarizedLightMicroscopy(PLM)
analysisandtheAmericanIndustrialHygieneAssociation(AIHA),LabID101533-AccreditationCertificate
#480forPhaseContrastMicroscopy(PCM)analysis.Thislaboratoryiscurrentlyproficientinboth
Proficiency Testing and PAT programs respectively.
ReservoirsEnvironmental,Inc.hasanalyzedthefollowingsamplesforasbestoscontentasperyour
request.Theanalysishasbeencompletedingeneralaccordancewiththeappropriatemethodologyas
stated in the attached analysis table. The results have been submitted to your office.
Herron Enterprises, USA, Inc.
7261 W. Hampden Ave.
Lakewood CO 80227
None Given
P: 303-964-1986
F: 303-477-4275
5801 Logan Street, Suite 100 Denver, CO 80216
Page 1 of 2
1-866-RESI-ENV
www.reilab.com
Re
s
e
r
v
o
i
r
s
E
n
v
i
r
o
n
m
e
n
t
a
l
,
I
n
c
.
Re
s
e
r
v
o
i
r
s
E
n
v
i
r
o
n
m
e
n
t
a
l
Q
A
M
a
n
u
a
l
Effective January 1, 2012
T:
\
Q
A
Q
C
\
L
a
b
\
R
e
s
e
r
v
o
i
r
s
E
n
v
i
r
o
n
m
e
n
t
a
l
Q
A
M
a
n
u
a
l
.
d
o
c
TA
B
L
E
P
L
M
B
U
L
K
A
N
A
L
Y
S
I
S
,
P
E
R
C
E
N
T
A
G
E
C
O
M
P
O
S
I
T
I
O
N
B
Y
V
O
L
U
M
E
RE
S
J
o
b
N
u
m
b
e
r
:
Cl
i
e
n
t
:
Cl
i
e
n
t
P
r
o
j
e
c
t
N
u
m
b
e
r
/
P
.
O
.
:
Cl
i
e
n
t
P
r
o
j
e
c
t
D
e
s
c
r
i
p
t
i
o
n
:
Da
t
e
S
a
m
p
l
e
s
R
e
c
e
i
v
e
d
:
An
a
l
y
s
i
s
T
y
p
e
:
ND=None Detected
Tu
r
n
a
r
o
u
n
d
:
TR=Trace, <1% Visual Estimate
Da
t
e
A
n
a
l
y
z
e
d
:
Trem-Act=Tremolite-Actinolite
Cl
i
e
n
t
NonNon-
Sa
m
p
l
e
Su
b
AsbestosFibrous
Nu
m
b
e
r
Ph
y
s
i
c
a
l
P
a
r
t
F
i
b
r
o
u
s
C
o
m
p
o
n
e
n
t
s
De
s
c
r
i
p
t
i
o
n
(
%
)
Mi
n
e
r
a
l
V
i
s
u
a
l
Components(%)
Es
t
i
m
a
t
e
(
%
)
(%)
.
07
1
0
1
2
-
1
A
EM
1
4
8
3
6
6
A
B
l
u
e
p
a
i
n
t
w
/
w
h
i
t
e
c
o
m
p
o
u
n
d
2
ND0100
B
W
h
i
t
e
/
b
r
o
w
n
d
r
y
w
a
l
l
9
8
ND1585
07
1
0
1
2
-
1
B
EM
1
4
8
3
6
7
A
B
l
u
e
p
a
i
n
t
w
/
w
h
i
t
e
c
o
m
p
o
u
n
d
2
ND0100
B
W
h
i
t
e
/
b
r
o
w
n
d
r
y
w
a
l
l
9
8
ND1585
07
1
0
1
2
-
1
C
EM
1
4
8
3
6
8
A
B
l
u
e
p
a
i
n
t
1
ND0100
B
W
h
i
t
e
t
a
p
e
5
ND955
C
W
h
i
t
e
c
o
m
p
o
u
n
d
7
ND0100
D
W
h
i
t
e
/
b
r
o
w
n
d
r
y
w
a
l
l
8
7
ND1585
07
1
0
1
2
-
2
A
EM
1
4
8
3
6
9
A
W
h
i
t
e
g
r
o
u
t
T
R
ND0100
B
B
r
o
w
n
f
i
b
r
o
u
s
m
a
t
e
r
i
a
l
2
ND955
C
T
a
n
m
a
s
t
i
c
3
ND0100
D
W
h
i
t
e
c
e
r
a
m
i
c
t
i
l
e
9
5
ND0100
07
1
0
1
2
-
3
A
EM
1
4
8
3
7
0
A
W
h
i
t
e
c
e
r
a
m
i
c
t
i
l
e
1
0
0
ND0100
RE
S
E
R
V
O
I
R
S
E
N
V
I
R
O
N
M
E
N
T
A
L
,
I
N
C
.
NV
L
A
P
L
a
b
C
o
d
e
1
0
1
8
9
6
-
0
TD
H
L
i
c
e
n
s
e
d
L
a
b
o
r
a
t
o
r
y
#
3
0
-
0
1
3
6
ID
N
u
m
b
e
r
L A Y E R
La
b
2
H
o
u
r
RE
S
2
3
9
8
6
0
-
1
07
1
0
1
2
6
He
r
r
o
n
E
n
t
e
r
p
r
i
s
e
s
,
U
S
A
,
I
n
c
.
Asb
e
s
t
o
s
C
o
n
t
e
n
t
Ju
l
y
1
1
,
2
0
1
2
No
n
e
G
i
v
e
n
PL
M
,
S
h
o
r
t
R
e
p
o
r
t
Ju
l
y
1
2
,
2
0
1
2
TE
M
A
n
a
l
y
s
i
s
r
e
c
o
m
m
e
n
d
e
d
f
o
r
o
r
g
a
n
i
c
a
l
l
y
b
o
u
n
d
m
a
t
e
r
i
a
l
(
i
.
e
.
f
l
o
o
r
t
i
l
e
)
i
f
P
L
M
r
e
s
u
l
t
s
a
r
e
<
1
%
.
P:
3
0
3
-
9
6
4
-
1
9
8
6
F:
3
0
3
-
4
7
7
-
4
2
7
5
5
8
0
1
L
o
g
a
n
S
t
r
e
e
t
,
S
u
i
t
e
1
0
0
D
e
n
v
e
r
,
C
O
8
0
2
1
6
Pa
g
e
2
o
f
2
_______Data QA 1-866-RESI-ENV www.reilab.com