HomeMy WebLinkAboutPEC120026 DRB120250 approved plans193 EAST GORE CREEK DRIVE VAIL, CO 81657 DRB & PEC 2012.06.25 GORE CREEK TENANT RENOVATION REVISIONS 2012.07.09 1 120600 2012.07.09 DHS SB COVER SHEET A0.0 1. THE GENERAL CONTRACTOR IS SUPPLIED, HEREIN, WITH THE CONSTRUCTION DOCUMENTS FOR USE IN PRICING & CONSTRUCTING THIS WORK. IT IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS & NOTIFY THE ARCHITECT OF ANY DISCREPANCIES & UNFORESEEN CONDITIONS & COORDINATE PRICING & CONSTRUCTION INFORMATION ACCORDINGLY. PROVIDE &INSTALL ADEQUATE BLOCKING IN WALLS TO RECEIVE ALL ATTACHED EQUIP., PLUMBING, FIXTURES FIXTURES, MILLWORK, & CASEWORK.2. CONTRACTOR IS RESPONSIBLE FOR FIELD INSPECTION OF ALL SURFACES TO RECEIVE PAINT OR OTHER FINISH TREATMENT & FOR ASSUMING THAT SUCH SURFACES ARE ACCEPTABLE FOR FINISH APPLICATION PRIOR TO INITIATING ACTUAL FINISH WORK. NO PAINT FINISH SHALL BE APPLIED ON ANY SURFACE WHICH IMPROPERLY FINISHED, REPAIRED OR OTHERWISE NOT FULLY ACCEPTABLE FOR THE FINISH APPLICATION.ALL ROUGHNESS OR IRREGULARITIES THAT MAY APPEAR AFTER PRIMING SHALL BE THOROUGHLY FILED OR SANDED OUT OR OTHERWISE CORRECTED TO PROVIDE A SMOOTH, EVEN SURFACE FOR PAINTING &FINISHING. FINISHED APPLICATION & WALL APPEARANCE SHOULD BE FREE OF SURFACE & COLOR IRREGULARITIES.GORE CREEK TENANT RENOVATION - WINDOW TYPE - DOOR NUMBER - AREA NUMBER - ELEVATION NUMBER - BUILDING SECTION NUMBER - ELEVATION - WALL TYPE INDICATION [REFER TO ASSEMBLIES SHEET]- LEVEL - BUILDING SECTION SHEET NUMBER - ELEVATION SHEET NUMBER - DETAIL NUMBER - DETAIL SHEET NUMBER - WALL SECTION NUMBER - WALL SECTION SHEET NUMBER SPOT ELEVATION - INTERIOR ELEVATION NUMBER - INTERIOR ELEVATION SHEET NUMBER - REVISION (SIGNIFICANT ALTERATIONS/CORRECTIONS HAVE BEEN MADE WHEN DRAWING TITLE IS CLOUDED)- FIRE EXTINGUISHER CABINET LOCATION PROJECT ABBREVIATIONS PROJECT TEAM DIRECTORY SYMBOL LEGEND XX X AX.X X 100 X AX.X X +100'-0"Level 1 INTERIOR ELEVATION AX.X 1 AX.X 1 AX.X 1 EXTERIOR ELEVATION BUILDING SECTION WALL SECTION DETAIL CALLOUT - AREA NAME ROOM AREA 100 ENTRY FEC VICINITY MAP GENERAL CONSTRUCTION NOTES - WINDOW FRAME ELEVATION NUMBER - WINDOW FRAME ELEVATION SHEET NUMBER AX.X G1 WINDOW FRAME TYPE ELEVATION - GENERAL WORK NOTE [REFER TO LEGENDS]1 - FLOOR OR ROOF TYPE INDICATION [REFER TO ASSEMBLIES SHEET]X1 X - DEMOLITION FLAG NOTES -CEILING ELEVATION [RELATIVE TO ROOM FINISH FLOOR]+9'-0"X-1 -MATERIAL TAG [RE: FINISH SCHEDULE]NO.SHEET NAME DRAWING INDEX DESCRIPTIONS OF WORK POUNDS PER SQUARE INCH PT POST TENSIONED or PORCELAIN TILE PTD PAINTED PTDR PAPER TOWEL DISPENSER AND RECEPTACLE PTN PARTITION PTR PAPER TOWEL RECEPTACLE PVC POLYVINYL CHLORIDE PVMT PAVEMENT QT QUARRY TILE QTY QUANTITY (R)REMOVE R RISER RAD RADIUS RB RUBBER BASE RBC RUBBER BASE COVE RBS RUBBER BASE STRAIGHT RBT RUBBER TILE RD ROOF DRAIN or ROAD RE REFER TO or REFERENCE REC RECESS(ED)RECPT RECEPTACLE REF REFRIGERATOR or REFRIGERATED REINF REINFORCED REQD REQUIRED RESIL RESILIENT REV REVISE, REVISED or REVISION(S)RF RESILIENT FLOORING RFG ROOFING RFL REFLECTED RH RIGHT HAND RL RAIN LEADER RM ROOM RO ROUGH OPENING ROD ROOF OVERFLOW DRAIN ROW RIGHT OF WAY RPM REVOLUTIONS PER MINUTE RVS REVERSE (SIDE)RWC RAIN WATER CONDUCTOR S SOUTH or SEALED SC SOLID CORE SCD SEAT COVER DISPENSER SCHED SCHEDULE SD SOAP DISPENSER SEC SECTION SF SQUARE FEET SHT SHEET SHTG SHEATHING SHWR SHOWER SIM SIMILAR SNC SANITARY NAPKIN CABINET SND SANITARY NAPKIN DISPENSER SNR SANITARY NAPKIN RECEPTACLE SOFF SOFFIT SPECS SPECIFICATION(S)SPKL SPRINKLER SPKR SPEAKER SPRT SUPPORT SQ SQUARE SR SINK RECEPTACLE SS STAINLESS STEEL SSK SERVICE SINK STA STATION STD STANDARD STL STEEL STOR STORAGE STRUCT STRUCTURE or STRUCTURAL SUSP SUSPEND(ED)SYM SYMMETRICAL SYS SYSTEM T TREAD T&B TOP AND BOTTOM T&G TONGUE AND GROOVE TB TOWEL BAR TBC TOP OF BACK OF CURB TELE TELEPHONE TEMP TEMPORARY or TEMPERATURE TG TEMPERED GLASS THERM THERMOSTAT THK THICK or THICKNESS THLD THRESHOLD TO TOP OF TOC TOP OF CONCRETE TOS TOP OF STEEL TOW TOP OF WALL TPD TOILET PAPER DISPENSER TPTN TOILET PARTITION TS TUBE STEEL TV TELEVISION TYP TYPICAL UL UNDERWRITER'S LABORATORY UNFIN UNFINISHED UON UNLESS OTHERWISE NOTED UR.URINAL USGS U.S. GEOLOGICAL SURVEY V VOLT VAR VARY or VARIES VB VAPOR BARRIER VCT VINYL COMPOSITION TILE VENT VENTILATION VER VERIFY VERT VERTICAL VEST VESTIBULE VIF VERIFY IN FIELD VIN VINYL or SHEET VINYL VOL VOLUME VTR VENT THROUGH ROOF VWC VINYL WALL COVERING W WEST or WIDE W.O.WHERE OCCURS W/WITH W/C WATER CLOSET W/O WITHOUT W/R WATER RESISTANT WC WALL COVERING WD WOOD WDO WINDOW WF.WIDE FLANGE or WOOD FLOORING WGL WIRE GLASS WP WATERPROOF(ING)WPT WORKING POINT WSCT TRUE NORTH MINOR EXTERIOR ALTERATION AND TENANT FINISH OF THE EXISTING INTERIORS TO UTILIZE THE SPACE AS A DRINKING/EATING ESTABLISHMENT. WORK INCLUDES ALL NECESSARY ARCHITECTURAL,MECHANICAL, PLUMBING, ELECTRICAL & KITCHEN EQUIPMENT SCOPE. DESIGN DOES NOT PROPOSE A CHANGE IN NET SQUARE FOOTAGE TO EXISTING USABLE AREA.DEMOLITION A0.0 COVER SHEET A1.0 MAIN LEVEL FLOOR PLAN A1.1 MAIN LEVEL FINISH FLOOR PLAN A2.1 EXISTING BUILDING ELEVATION - NORTH ELECTRICAL and LIGHTING E1.0 LEVEL 1 EXTERIOR LIGHTING PLAN MECHANICAL and PLUMBING M5.0 MECHANICAL EAST ELEVATION PREFIN PREFINISHED PRESTR PRESTRESSED PRIM PRIMARY PROJ PROJECT PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT POST TENSIONED or PORCELAIN TILE PTD PAINTED PTDR PAPER TOWEL DISPENSER AND RECEPTACLE PTN PARTITION PTR PAPER TOWEL RECEPTACLE PVC POLYVINYL CHLORIDE PVMT PAVEMENT QT QUARRY TILE QTY QUANTITY (R)REMOVE R RISER RAD RADIUS RB RUBBER BASE RBC RUBBER BASE COVE RBS RUBBER BASE STRAIGHT RBT RUBBER TILE RD ROOF DRAIN or ROAD RE REFER TO or REFERENCE REC RECESS(ED)RECPT RECEPTACLE REF REFRIGERATOR or REFRIGERATED REINF REINFORCED REQD REQUIRED RESIL RESILIENT REV REVISE, REVISED or REVISION(S)RF RESILIENT FLOORING RFG ROOFING RFL REFLECTED RH RIGHT HAND RL RAIN LEADER RM ROOM RO ROUGH OPENING ROD ROOF OVERFLOW DRAIN ROW RIGHT OF WAY RPM REVOLUTIONS PER MINUTE RVS REVERSE (SIDE)RWC RAIN WATER CONDUCTOR S SOUTH or SEALED SC SOLID CORE SCD SEAT COVER DISPENSER SCHED SCHEDULE SD SOAP DISPENSER SEC SECTION SF SQUARE FEET SHT SHEET SHTG SHEATHING SHWR SHOWER SIM SIMILAR SNC SANITARY NAPKIN CABINET SND SANITARY NAPKIN DISPENSER SNR SANITARY NAPKIN RECEPTACLE SOFF SOFFIT SPECS SPECIFICATION(S)SPKL SPRINKLER SPKR SPEAKER SPRT SUPPORT SQ SQUARE SR SINK RECEPTACLE SS STAINLESS STEEL SSK SERVICE SINK STA STATION STD STANDARD STL STEEL STOR STORAGE STRUCT STRUCTURE or STRUCTURAL SUSP SUSPEND(ED)SYM SYMMETRICAL SYS SYSTEM T TREAD T&B TOP AND BOTTOM T&G TONGUE AND GROOVE TB TOWEL BAR TBC TOP OF BACK OF CURB TELE TELEPHONE TEMP TEMPORARY or TEMPERATURE TG TEMPERED GLASS THERM THERMOSTAT THK THICK or THICKNESS THLD THRESHOLD TO TOP OF TOC TOP OF CONCRETE TOS TOP OF STEEL TOW TOP OF WALL TPD TOILET PAPER DISPENSER TPTN TOILET PARTITION TS TUBE STEEL TV TELEVISION TYP TYPICAL UL UNDERWRITER'S LABORATORY UNFIN UNFINISHED UON UNLESS OTHERWISE NOTED UR.URINAL USGS U.S. GEOLOGICAL SURVEY V VOLT VAR VARY or VARIES VB VAPOR BARRIER VCT VINYL COMPOSITION TILE VENT VENTILATION VER VERIFY VERT VERTICAL VEST VESTIBULE VIF VERIFY IN FIELD VIN VINYL or SHEET VINYL VOL VOLUME VTR VENT THROUGH ROOF VWC VINYL WALL COVERING W WEST or WIDE W.O.WHERE OCCURS W/WITH W/C WATER CLOSET W/O WITHOUT W/R WATER RESISTANT WC WALL COVERING WD WOOD WDO WINDOW WF.WIDE FLANGE or WOOD FLOORING WGL WIRE GLASS WP WATERPROOF(ING)WPT WORKING POINT WSCT WAINSCOT WT WEIGHT WWF WELDED WIRE FABRIC YARD FLR FLOOR(ING)FLUOR FLUORESCENT FOC FACE OF CONCRETE FOF FACE OF FINISH FOM FACE OF MASONRY FOS FACE OF STUD FR FIRE RESISTIVE or FIRE RATED FRP FIBERGLASS REINFORCED PANEL(ING)FRT FIRE RETARDANT TREATED FT FOOT (FEET)FTG FOOTING FURN FURNISH(ED)FURR FURRED or FURRING FUT FUTURE FVC FIRE VALVE CABINET GA GAUGE GALV GALVANIZED GB GRAB BAR GC GENERAL CONTRACTOR GCMU GLAZED CONCRETE MASONRY UNIT(S)GL GLASS or GLAZING GND GROUND GR GRADE GRT GROUT GWB GYPSUM WALLBOARD GYP GYPSUM GYP. BD.GYPSUM BOARD HAS HEADED ANCHOR STUD HB HOSE BIB HC HOLLOW CORE or HANDICAPPED HDAS HEADED DEFORMED ANCHOR STUD HDR HEADER HDWR HARDWARE HM HOLLOW METAL HORIZ HORIZONTAL HR HOUR HT HEIGHT HTR HEATER HVAC HEATING, VENTILATION and AIR CONDITIONING HW HOT WATER HWH HOT WATER HEATER HWY HIGHWAY IBC INTERNATIONAL BUILDING CODE ID INSIDE DIAMETER IN INCH(ES)INCAND INCANDESCENT INCL INCLUD(ED)INFO INFORMATION INSUL INSULATION or INSULATED INT INTERIOR INTMED INTERMEDIATE INV INVERT JC JANITOR CLOSET JST JOIST JT JOINT KD KNOCKDOWN KIT KITCHEN KO KNOCKOUT KP KICK PLATE LAB LABORATORY LAM LAMINATE LAV LAVATORY LBL LABEL LDR LEADER LH LEFT HAND LKR LOCKER LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LP LIGHTING PANEL or LIGHT PROOF LT LIGHT LTL LINTEL LVR LOUVER MACH MACHINERY MAG MAGNETIC MAS MASONRY MATL MATERIAL MAX MAXIMUM MB MOISTURE BARRIER MECH MECHANICAL MED MEDIUM MEMB MEMBRANE MEP MECHANICAL, ELECTRICAL and PLUMBING MEZZ MEZZANINE MFR MANUFACTURER MH MANHOLE MIN MINIMUM MIRR MIRROR MISC MISCELLANEOUS MM MILLIMETERS MO MASONRY OPENING MTD MOUNT(ED)MTL METAL MUL MULLION (N)NEW N NORTH NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NRC NOISE REDUCTION COEFFICIENT NTS NOT TO SCALE OA OVERALL OC ON CENTER OD OUTSIDE DIAMETER OF OUTSIDE FACE OFF OFFICE OH OPPOSITE HAND OPNG OPENING OPP OPPOSITE OTO OUTSIDE-TO-OUTSIDE P PAINT(ED)P/L PROPERTY LINE PAC PREVIOUSLY AWARDED CONTRACT PAR PARALLEL PBO PROVIDED BY OTHERS PC PRECAST PERF PERFORATED PERIM PERIMETER PKG PARKING PL PLATE PLAM PLASTIC LAMINATE PLAS PLASTER PLBG PLUMBING PLYWD PLYWOOD PNL PANEL POL POLISHED PR PAIR or PROPOSAL REQUEST PREFAB PREFABRICATED POUND(S) or NUMBER AND ANGLE @ AT A/V AUDIO/VISUAL AB ANCHOR BOLT ABV ABOVE ACOUS ACCOUSTICAL ACT ACCOUSTICAL CEILING TILE AD AREA DRAIN or ACCESS DOOR ADD ADDENDUM ADJ ADJACENT or ADJUSTABLE AFF ABOVE FINISHED FLOOR AGG AGGREGATE AHU AIR HANDLING UNIT ALT ALTERNATE ALUM ALUMINUM ANOD ANODIZED APPROX APPROXIMATE ARCH ARCHITECTURAL ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS ASPH ASPHALT AUTO AUTOMATIC AVE AVENUE AVG AVERAGE AWP ACOUSTICAL WALL PANEL BASE B.O.BY OWNER B.O.F.BY OWNER, FUTURE BD BOARD BIT BITUMINOUS BLDG BUILDING BLKG BLOCKING BM BEAM or BENCH MARK BOT BOTTOM BRG BEARNING BSMT BASEMENT C CAULKING C.L.CENTERLINE CAB CABINET CATV CABLE TELEVISION CCD CONSTRUCTION CHANGE DIRECTIVE CCTV CLOSED CIRCUIT TELEVISION CDOT COLORADO DEPARTMENT OF TRANSPORTATION CEM CEMENTITIOUS CFL COUNTERFLASHING CG CORNER GUARD CIP CAST IN PLACE CIRC CIRCUMFERENCE CJ CONTROL JOINT CL COLUMN LINE CLG CEILING CLOS CLOSET CLR CLEAR CM CENTIMETERS CMU CONCRETE MASONRY UNIT CO CHANGE ORDER or CLEANOUT COL COLUMN CONC CONCRETE CONF CONFERENCE CONN CONNECTION CONSTR CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CORR CORRIDOR or CORRUGATED CPT CARPET CT CERAMIC TILE CTR COUNTER CU CUBIC CY CUBIC YARD DAMP DAMPROOFING DBL DOUBLE DEG DEGREE DEMO DEMOLISH or DEMOLITION DEPT DEPARTMENT DF DRINKING FOUNTAIN DIA DIAMETER DIAG DIAGONAL DIM DIMENSION DISP DISPENSER DIV DIVISION DN DOWN DR DOOR DS DOWNSPOUT DTL DETAIL DWG DRAWING DWR DRAWER (E)EXISTING EAST EA EACH EB EXPANSION BOLT ED EXHAUST DUCT EF EXHAUST FAN or EACH FACE EJ EXPANSION JOINT EL ELEVATION ELEC ELECTRICAL ELEV ELEVATOR EMER EMERGENCY ENGR ENGINEER EOS EDGE OF SLAB EQ EQUAL EQUIP EQUIPMENT ES EACH SIDE EST ESTIMATE EW EACH WAY EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EXT EXTERIOR FARENHEIT FA FIRE ALARM FAC FIRE ALARM CABINET FACP FIRE ALARM CONTROL PANEL FBO FURNISHED BY OTHER(S)FD FLOOR DRAIN or FIRE DAMPER FDN FOUNDATION FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FF FINISHED FLOOR FFL FINISHED FLOOR LINE FH FIRE HYDRANT FHC FIRE HOSE CABINET FHMS FLAT HEAD MACHINE SCREW FHV FIRE HOSE VALVE FHWS FLAT HEAD WOOD SCREW FIN FINISH(ED)FIXT FIXTURE FLG FLASHING YD <&#D1.0 MAIN LEVEL DEMOLITION FLOOR PLAN D1.1 LEVEL 1 DEMOLITION ROOF PLAN ARCHITECTURAL A2.2 EXISTING BUILDING ELEVATION - EAST A2.3 EXISTING BUILDING ELEVATION - SOUTH A2.4 EXISTING BUILDING ELEVATION - WEST A2.5 NEW BUILDING ELEVATION - NORTH A2.6 A2.7 A2.8 NEW BUILDING ELEVATION - EAST NEW BUILDING ELEVATION - SOUTH NEW BUILDING ELEVATION - WEST 193 GORE CREEK DRIVE, UNITS A & D VAIL, CO 81657 ARCHITECT OWNERS MATT MORGAN &KEVIN CLAIR 193 GORE CREEK DRIVE,SUITE 201, VAIL, CO 81657 PH: 970.476.0125 FAX: 970.476.0137 CONTACT:MATT MORGAN-matt@sweetbasil-vail.com GENERAL CONTRACTOR ROCKY MOUNTAIN CONSTRUCTION GROUP 120 WILLOW BRIDGE RD SUITE 7 VAIL, CO. 81657 PH: 970-476-4458 FAX#: 970 476-4951 CONTACT:MARK HALLENBECK -mark@rockymountainconstructiongroup.com MECH. ENGINEER Rader Engineering, Inc.40690 Highway 6, Suite E1 P.O. Box 8610 Avon, CO 81620 PH: 970-845-7910 FAX: 970-845-7522 CONTACT:BRYAN HOULE -Bryan@raderengineering.com KITCHEN EQUIPMENT Tundra Specialties Design Group 3825 Walnut St.Boulder, CO 80301 PH: 303-545-1365 CONTACT:JEFF KATZ -JKatz@etundra.com Occupant Load [Table 1004.1.1]The Maximum Floor Area Allowances per Occupant are:-Assembly without fixed seats (Unconcentrated-tables and chairs): 15 sf net -Storage 300 sf gross -Mechanical 300 sf gross -Kitchens [Commercial]200 sf gross 903.2.1.2 Group A-2.An automatic sprinkler system shall be provided for Group A-2 occupancies where one of the following conditions exists:1. The fire area exceeds 5,000 square feet (465 m2);2. The fire area has an occupant load of 100 or more;3. The fire area is located on a floor other than the level of exit discharge.*Note: Current program exceeds occupant load of 100 persons, therefore an automatic sprinkler system is required & provided.1004.7 Fixed seating."For areas having fixed seats and aisles,the occupant load shall be determined by the number of fixed seats installed therein. The occupant load for areas in which fixed seating is not installed, such as waiting spaces and wheelchair spaces, shall be determined in accordance with Section 1004.1.1 and added to the number of fixed seats.""...The occupant load of seating booths shall be based on one person for each 24 inches (610 mm) of booth seat length measured at the backrest of the seating booth."Occupant Load Calculations:LEVEL 1:-West Banquette & Bar Seating Areas [Fixed Seating-See Section 1004.7]: 28 OCCS -West Open Seating Area [Loose Seating]: 500 sf / 15 net = 20.73 OCCS -Kitchen & Beer Cooler/Storage area: 1,262 sf / 200 = 6.31 OCCS -Janitor Closet, Water & Mechanical: 122 sf / 300 = 0.41 OCC TOTAL MAIN LEVEL = 136.45 OCCS TOTAL OCCUPANT LOAD = 137 OCCS -Patio Areas: 316 sf / 15 net = 21.06 OCCS 193 Gore Creek Drive Tenant Renovation Code Analysis Project Number:120600.vtav Project Location:193 GORE CREEK DRIVE, UNITS A & D, VAIL, CO 81657 Applicable Codes:,QWHUQDWLRQDO%XLOGLQJ&RGH(GLWLRQ ,QWHUQDWLRQDO0HFKDQLFDO&RGH(GLWLRQ ,QWHUQDWLRQDO3OXPELQJ&RGH(GLWLRQ ,QWHUQDWLRQDO(QHUJ\&RQVHUYDWLRQ&RGH(GLWLRQ ,QWHUQDWLRQDO)XHO *DV&RGH(GLWLRQ ,QWHUQDWLRQDO)LUH&RGH(GLWLRQ 1DWLRQDO(OHFWULFDO&RGH(GLWLRQ (DJOH&RXQW\,%&$PHQGPHQWV =RQLQJ5HJXODWLRQV Building Classification[s] per Section 303:Although this space may eventually include accessory occupancies, this area of the building will be evaluated as A-2 because of the specific functions within.A-2:"Assembly uses intended for food and/or drink consumption including, but not limited to Banquet halls, Night clubs, Restaurants, Taverns and Bars".Construction Type Proposed [Section 602]:Type II-A [Fully Sprinklered]Local Zoning District:CC1 [COMMERCIAL CORE-1]Allowable Height [Table 503]:15,500 SF for A-2; 65 feet max; 3-stories max Proposed Existing Renovated Building Area:3,912 gross sq ft plus 374 sf Outdoor Patio Area Proposed New Building Area:0 net sq ft Fire Resistive Requirements per Table 601 for Type II-A construction*:STRUCTURAL FRAME 1 (1 HR < 20')EXT. BEARING WALLS 1 (1 HR < 20') See Table 602 INT. BEARING WALLS 1 (1 HR < 20')EXT. NON-BEARING WALLS 1 (1 HR < 20')INT. PARTITIONS 0 (1 HR < 20')SHAFT ENCLOSURES 1 (1 HR < 20')FLOORS-CEILINGS/ROOFS 1 (1 HR < 20')ROOFS-CEILINGS/ROOFS 1 (1 HR < 20')2009 IECC Commerical Assemblies Table 502.2 [Climate Zone 6B]:*Note: R-values refer only to minimum amount of insulation required, not entire assemblies.Roofs:-Insulation entirely above deck: R-20 [continuous]-Attic & other: R-38 Walls, Above Grade:-Mass: R-13.3 [continuous]-Wood & Metal Framed: R-13 + R-7.5 [continuous]Walls, Below Grade:R-7.5 [continuous]Floors:-Mass: R-12.5 [continuous]-Joist/Framing: R-30 Slab on Grade:-Unheated: R-10 for 24-inches below -Heated: R-15 for 24-inches below Opaque Doors:-Swinging: U-0.70 -Roll-up or Sliding: U-0.50 Windows: [Table 502.3]-U-factor: 0.45 [curtain wall/storefront]-SHGC:-PF < 0.25: 0.40 0.25< PF > 0.5: No Requirement Plumbing fixture calculations [Table 2902.1]:137 total occupants 69 Men; 69 Women Water Closet ratio: Men-1 per 75; Women-1 per 75 Water Closets required: Men-1; Women-1 Water Closets provided: Men: 2 WCs ; Women: 2 WCs Lavatories ratio: Men & Women-1 per 200 Lavatories required: Men-1; Women-1 Lavatories provided: Men: 2 Lavs; Women: 2 Lavs Drinking fountain ratio:1 per 500 Drinking fountains required: 1 Drinking fountains provided: 1 Service sinks required: 1 Service sinks provided: 1 (*Per IPC 419.2, not more than 67% of required water closets may be replaced with urinals.)CIVIL ENGINEER:GORE RANGE SURVEYING, LLC PO BOX 15 5129 LONGSUN LANE AVON, CO 81620-0015 PH: (970) 479-8698 FAX: (970) 479-0055 CONTACT:SAM ECKER -sam@gorerange.net SEMPLE BROWN DESIGN, P.C.1160 SANTA FE DRIVE '(19(5&2¬PH: (303) 571.4137 FAX: (303) 571.0403 CONTACTS:DRU H SCHWYHART -dschwyhart@semplebrowndesign.com SARAH BROWN -sbrown@semplebrowndesign.com LIGHTING ENGINEER ARCHITECTURAL ENGINEERING DESIGN GROUP 1900 Wazee Street, Suite 350 Denver, Colorado 80202 PH: 303.296.3034 CONTACT:BRYAN JASS -bjass@aedesign-inc.com CIVIL C1.0 CIVIL SITE PLAN & SURVEY - EXISTING CONDITIONS EXHIBIT A4.0 NEW MATERIAL PALETTE A5.0 RENDERINGS A3.0 EXISTING CONDITIONS (PHOTOS)Frost Depth: 48" Below Grade Seismic Zone: C Snow Loads:Ground - 143 psf; Roof - 100 psf; Sloped Roofs (>4:12) - 80 psf; Decks (Uncovered) - 100 psf (Covered) - 80 psf Seismic Zone: C Wind Load: 90 MPH Seismic Zone: C *Footnote d: "An approved automatic sprinkler system in accordance with Section 903.3.1.1 shall be allowed to be substituted for I-hour fire-resistance-rated construction,provided such system is not otherwise required by other provisions of the code or used for an allowable area increase in accordance with Section 506.3 or an allowable height increase in accordance with Section 504.2. The1-hour substitution for the fire resistance of exterior walls shall not be permitted."LEGAL DESCRIPTION:UNITS 'A' & 'D' OF GORE CREEK PLAZA BUILDING, PART OF TRACT A, BLOCK 5-B, TOWN OF VAIL,COUNTY OF EAGLE , STATE OF COLORADO.-Bar area: 228 sf / 200 = 1.14 OCCS -East Banquette Seating Areas [Fixed Seating-See Section 1004.7]: 46 OCCS -East Open Seating Area [Loose Seating]: 192 sf / 15 net = 12.8 OCCS
UP (18 RISERS)UP (2 RISERS)4'-0" MO 5'-0" [VIF]GORE CREEK PROMENADE 3'-0" MO 1'-0"5'-8"2'-6"193 EAST GORE CREEK DRIVE VAIL, CO 81657 DRB & PEC 2012.06.25 GORE CREEK TENANT RENOVATION REVISIONS 2012.07.09 1 120600 2012.07.09 DHS SB LEVEL 1 DEMOLITION PLAN D1.0 LEVEL 1 DEMOLITION PLAN 1/4"=1'-0"4'2'1'0 NORTH TRUE NORTH PROJECT DEMOLISH EXISTING NON-STRUCTURAL DEMISING WALL[S]DEMOLISH EXISTING FURRING WALL[S]DEMOLISH ALL EXISTING NON-STRUCTURAL FRAMED WALLS [E] CONCRETE COLUMNS TO REMAIN REMOVE [E] SANDSTONE VENEER?REMOVE ALL EXISTING BRICK PAVER FLOORING IN THIS AREA [E] ELECTRICAL PANEL LOCATION REMOVE ALL [E]CARPET FLOORING DEMOLITION LEGEND GENERAL DEMO. NOTES 1.ASSUME ALL EXISTING FINISHES AND NON-STRUCTURAL FRAMING TO BE REMOVED.EXIST. CONSTRUCTION TO REMAIN DEMOLISH [E]RESTROOMS [E] CONCRETE COLUMN TO REMAIN [E] STEEL COLUMN TO REMAIN REMOVE [E] DOOR &PORTION OF EXISTING WALL [E] WALL TO REMAIN [E] STEEL COLUMN TO REMAIN REMOVE PORTIONS OF [E]BEARING WALL [E] MASONRY WALL TO REMAIN; REMOVE [E]SANDSTONE VENEER AT EXTERIOR [E] 12" MASONRY COLUMN TO REMAIN [E] 12" MASONRY COLUMN TO REMAIN DEMOLISH [E] BAR AND EQUIPMENT [E] 12" MASONRY COLUMN TO REMAIN REMOVE [E] WALL[S]DEMOLISH EXISTING VESTIBULE REMOVE [E] FOLDING GLASS DOOR REMOVE [E] AWNING &SLOPED GLAZING ROOF ABOVE [E] DEMISING WALL TO REMAIN [E] STEEL COLUMN TO REMAIN REMOVE EXISTING STOREFRONT WINDOW SYSTEM [E] STEEL COLUMN[S] TO REMAIN [E] STEEL PIPE COLUMN TO REMAIN [E] STEEL PIPE COLUMN TO REMAIN DEMOLISH ALL [E] FIXED SEATING AREA BANQUETTES [TYP]REPLACE EXISTING COOK LINE EXHAUST HOOD DEMOLISH [E] KITCHEN PARTITIONS [TYP][E] ELECTRICAL CONDUIT ABOVE TO REMAIN?[E] BEARING WALL TO REMAIN DEMOLITION PLAN NOTES:ALL (E) PARKING GARAGE AREAS TO REMAIN UNDISTURBED.1 [E] PARKING GARAGE XX [E] FOOD STORAGE XX [E] VESTIBULE XX [E] ELEVATOR XX [E] STORAGE XX [E] MENS XX [E] WOMENS XX [E] WALK-IN COOLER XX [E] PREP AREA XX [E] MECHANICAL XX [E] BAR [E] BANQUETTES XX [E] VESTIBULE XX [E] UNOCCUPIED RETAIL XX [E] DINING AREA XX [E] WAITING XX [E] DISHWASHING XX [E] HALL XX [E] COOK LINE XX DEMOLISH ALL EXISTING NON-STRUCTURAL FRAMED WALLS & LOW WALLS IN [E]DINING AREA [TYP][E] SOFFIT AT UNDERSIDE OF STAIR TO REMAIN FIELD VERIFY [E] COLUMN LOCATION EXIST. CONSTRUCTION TO DEMOLISHED EXIST. DOOR TO BE DEMOLISHED EXIST. DOOR TO REMAIN [E] 1'-0" W.x12'-0" L. CONCRETE FOOTING BELOW TO REMAIN REMOVE [E] DOOR &PORTION OF EXISTING WALL [E] 3" DIA. STEEL PIPE COLUMNS & WIDE FLANGE ABOVE TO REMAIN [E] MECH./ELECT.XX [E] MASONRY WALL TO REMAIN; REMOVE [E]SANDSTONE VENEER AT EXTERIOR [E] WATER XX [E] CONCRETE FOUNDATION WALL TO REMAIN [VIF][E] FOUNDATION TO REMAIN [VIF]DEMOLISH [E] DOWNSPOUT; RE-USE EXISTING TIE-IN TO STORM PIPING [E] STORM PIPING TO REMAIN [E] FLOOR SLAB +100'-0" (8158'-10")REMOVE [E] DOOR AND PORTION OF WALL
GORE CREEK DRIVE UP (4 RISERS)DOWN (18 RISERS)GORE CREEK PROMENADE UP (17 RISERS)UP (6 RISERS)193 EAST GORE CREEK DRIVE VAIL, CO 81657 DRB & PEC 2012.06.25 GORE CREEK TENANT RENOVATION REVISIONS 2012.07.09 1 120600 2012.07.09 DHS SB LEVEL 2 DEMOLITION PLAN D1.1 LEVEL 2 DEMOLITION PLAN 1/4"=1'-0"4'2'1'0 NORTH TRUE NORTH PROJECT [E] ELEVATOR E02 [E] SWEET BASIL 200 REMOVE EXISTING SLOPED GLAZING & AWNING REMOVE EXISTING SLOPED GLAZING & AWNING DEMOLITION LEGEND GENERAL DEMO. NOTES 1.ASSUME ALL EXISTING FINISHES AND NON-STRUCTURAL FRAMING TO BE REMOVED.EXIST. CONSTRUCTION TO REMAIN DEMOLITION PLAN NOTES:ALL (E) PARKING GARAGE AREAS TO REMAIN UNDISTURBED.EXIST. CONSTRUCTION TO DEMOLISHED EXIST. DOOR TO BE DEMOLISHED EXIST. DOOR TO REMAIN [E] RETAIL 250 [E] STEEL COLUMN TO REMAIN DEMOLISH [E] PARTITION [E] CLOSET 203 [E] ADA WASHROOM 201 [E] VESTIBULE 201 [E] MENS WASHROOM 201 [E] CORRIDOR 202 [E] CORRIDOR 204 REPLACE [E] TOILET FIXTURES REPLACE [E] TOILET FIXTURES REMOVE [E] DOOR &PORTION OF [E] WALL REMOVE [E] DOOR AND ASSOCIATED WALLS REMOVE PORTION OF [E]WINDOW SYSTEM FOR NEW DOOR TO ROOF DECK
Xref /Users/Roy/Documents/Tundra Design Group/Projects/BBG_Basil Bar and Grill/04-Drawings/02-Current Drawings/x-BBG_plan.dwg UP (18 RISERS)UP (2 RISERS)23'-4" [VIF]4'-0" MO 5'-0" [VIF]4'-0" [MIN]22'-10"11'-2"3'-6"18'-6"4'-4"8'-6 1/4" [VIF]GORE CREEK PROMENADE 3'-0" MO 1'-0"5'-8"2'-6"10'-0" CLEAR [MIN]7'-6" MAX [PATIO]5'-6" MAX [VIF]10'-1" [VIF]26'-4" [PATIO]4'-4"1'-8 1/2"5'-0"4'-0"4'-0"6'-6" [CLR]193 EAST GORE CREEK DRIVE VAIL, CO 81657 DRB & PEC 2012.06.25 GORE CREEK TENANT RENOVATION REVISIONS 2012.07.09 1 REVISIONS 2012.07.16 2 120600 2012.07.09 DHS SB LEVEL 1 FLOOR PLAN A1.0 LEVEL 1 FLOOR PLAN 1/4"=1'-0"4'2'1'0 NORTH TRUE NORTH PROJECT FLOOR PLAN NOTES:(E) BASEMENT STORAGE TO REMAIN 1 WALK-IN COOLER EXTRUDED POLYSTYRENE INSULATION SPECS TO MEET OWENS CORNING - UL FOAM CORE 5 FLAME SPREAD RATING WITH AVG SMOKE RATING LESS THAT 175 (UL 723)2 LOCKED LIQUOR STORAGE 3 GENERAL CONST. NOTES 1.ALL SUBCONTRACTORS ARE RESPONSIBLE TO REVIEW ALL ARCHITECTURAL DRAWINGS AND INCLUDE ANY STRUCTURAL, ELECTRICAL, PLUMBING OR MECHANICAL CALLED OUT ON ARCHITECTURAL DRAWINGS THAT MAY BE MISSING FROM ENGINEERED DRAWINGS.2.ALL DIMENSIONS ARE TO FINISH FACE OF WALL OR STRUCTURAL GRID LINE.3.COORDINATE LOCATION OF ALL ACCESS PANELS W/ARCHITECT PRIOR TO INSTALLATION.4.ALL FURNISHINGS AND KITCHEN EQUIPMENT ARE BY OTHERS. G.C. RESPONSIBLE TO COORDINATE W/ KITCHEN DESIGNER, DRAFT, POS, A/V, FURNITURE & BOOTH CONSULTANTS TO PROVIDE OWNER W/COMPLETE PROJECT.5.ASSUME ALL EXISTING FINISHES AND NON-STRUCTURAL FRAMING TO BE REMOVED IN LEVEL 1 COMMERCIAL UNIT 'A'.6.ALL INTERIOR CONSTRUCTION AT LEVEL 2 TO REMAIN UNDISTURBED.SEE SHEET A4.0 FOR EMPLOYEE RESTROOM FIXTURES & FINISHES 4 [E] PARKING GARAGE XX COOLER 109 [E] ELEVATOR E01 PREP 107 [E] MECHANICAL XX SERVER STATION 114 VESTIBULE 100 DISHWASHING 112 COOK LINE 106 BAR 122 HOST 101 [E] MECH./ELECT.120 ICE 113 PICK UP HALL 115 NEW W8X40 STEEL COLUMN [RE:STRUCT.]NEW ALUMINUM FRAME INTERIOR FOLDING OR SLIDING GLASS DOOR NEW FRAMELESS STEEL & GLASS ENTRY DOOR NEW ALUMINUM FRAME INTERIOR FOLDING POCKET DOOR W/INTEGRAL SWINGING DOOR REPLACE [E] MTL DOWNSPOUT NEW W8X40 STEEL COLUMN [RE: STRUCT.][E] WATER XX WOOD GRILLE 105 NEW FRAMELESS GLASS ENTRY VESTIBULE ADA WASHROOM 119 BEER COOLER 123 WEST PATIO EAST PATIO 125 10' CLEAR SETBACK LINE FROM EDGE OF PAVERS FOR PROMENADE DOUBLE LINE INDICATES 36" H.GUARDRAIL AT PROPOSED PATIO EXTENTS WHEN WEATHER PERMITS WASHROOM 116 [E] WOOD FENCE TO REMAIN [E] ELECTRICAL TO REMAIN JANITOR 111 NEW FINISH FLOOR [TBD]EDGE OF PROMENADE PAVERS DOUBLE LINE INDICATES 36" H.GUARDRAIL AT PROPOSED PATIO EXTENTS WHEN WEATHER PERMITS NOTE: TOTAL OCCUPANT COUNT NOT TO EXCEED 149 PERSONS [MAX INTERIOR AND EXTERIOR].EDGE OF PROMENADE PAVERS [VIF]SITE COVERAGE CALC.EXISTING SITE COVERAGE:0.173 ACRES LOT BOUNDARY [7,535 SQ. FT.]EXISTING BUILDING FOOTPRINT: 6,437 SQ. FT.6,437 / 7,535 = 85.42%PROPOSED SITE COVERAGE:0.173 ACRES LOT BOUNDARY [7,535 SQ. FT.]PROPOSED BUILDING FOOTPRINT: 6,246 SQ. FT.6,417 / 7,535 = 85.16%STORAGE 122 [E] CONC. SLAB 100'-0" [8158'-10"]FREEZER 110 NEW LOUVER FOR GENERAL EXHAUST [RE: ELEVATIONS][E] STEEL PIPE COLUMNS AND BEAMS OVERHEAD TO REMAIN ADA WASHROOM 118 102 100 101 121 115A 116 117 111 115B 108 120 119 118 100 EAST DINING AREA 102 WEST DINING AREA 121 POS STATION 103 HALL 108 122 WOOD STORAGE IN STEEL CLAD STOREFRONT AREA WASHROOM 117
GORE CREEK DRIVE UP (4 RISERS)DOWN (18 RISERS)EXISTING ROOF NEW ROOF GORE CREEK PROMENADE UP (17 RISERS)UP (6 RISERS)2'-5 1/2"7 1/2"193 EAST GORE CREEK DRIVE VAIL, CO 81657 DRB & PEC 2012.06.25 GORE CREEK TENANT RENOVATION REVISIONS 2012.07.09 1 REVISIONS 2012.07.16 2 120600 2012.07.09 DHS SB LEVEL 2 FLOOR PLAN A1.1 LEVEL 2 FLOOR PLAN 1/4"=1'-0"4'2'1'0 NORTH TRUE NORTH PROJECT [E] SWEET BASIL 200 ROOF PLAN NOTES:TIE IN NEW ROOF DRAIN PIPES AND DOWNSPOUTS TO EXISTING STORM DRAINAGE SYSTEM.1 PLAN LEGEND NEW WALL CONSTRUCTION GENERAL CONST. NOTES 1.ALL SUBCONTRACTORS ARE RESPONSIBLE TO REVIEW ALL ARCHITECTURAL DRAWINGS AND INCLUDE ANY STRUCTURAL,ELECTRICAL, PLUMBING OR MECHANICAL CALLED OUT ON ARCHITECTURAL DRAWINGS THAT MAY BE MISSING FROM ENGINEERED DRAWINGS.2.ALL DIMENSIONS ARE TO FINISH FACE OF WALL OR STRUCTURAL GRID LINE.3.COORDINATE LOCATION OF ALL ACCESS PANELS W/ARCHITECT PRIOR TO INSTALLATION.4.ALL FURNISHINGS AND KITCHEN EQUIPMENT ARE BY OTHERS.G.C. RESPONSIBLE TO COORDINATE W/ KITCHEN DESIGNER,DRAFT, POS, A/V, FURNITURE & BOOTH CONSULTANTS TO PROVIDE OWNER W/COMPLETE PROJECT.5.ASSUME ALL EXISTING FINISHES AND NON-STRUCTURAL FRAMING TO BE REMOVED IN LEVEL 1 COMMERCIAL UNIT 'A'.EXIST. CONSTRUCTION TO REMAIN EXIST. DOOR TO REMAIN NEW DOOR EDGE OF NEW FLAT ROOF DBL DASHED LINE INDICATES LOCATION OF EXTERIOR WALL BELOW [E] FLAT ROOF TO REMAIN REPLACE [E] MTL DOWNSPOUT W/ NEW STL DRAIN PIPE DASHED LINE INDICATES [E]EXTERIOR SOFFIT ABOVE [E] DUMPSTER ENCLOSURE AREA TO REMAIN [E] SPIRAL STAIR INTEGRAL GUTTER NEW ROOF DRAIN; TIE INTO [E] STORM DRAIN PIPE BELOW 1/4:12 SLOPE GUTTER SLOPE 1/4:12 SLOPE [E] DOWNSPOUT TO BE RELOCATED; NEW COLLECTION BOX AT SOUTH ROOF EDGE [E] DOWNSPOUT FROM UPPER ROOF TO REMAIN [E] SWEET BASIL +110'-0" [8168'-10"]SEE ELEVATIONS FOR MORE INFO ON EXISTING AND NEW MECHANICAL EQUIPMENT SITE COVERAGE CALC.EXISTING SITE COVERAGE:0.173 ACRES LOT BOUNDARY [7,535 SQ. FT.]EXISTING BUILDING FOOTPRINT: 6,437 SQ. FT.6,437 / 7,535 = 85.42%PROPOSED SITE COVERAGE:0.173 ACRES LOT BOUNDARY [7,535 SQ. FT.]PROPOSED BUILDING FOOTPRINT: 6,246 SQ. FT.6,417 / 7,535 = 85.16%[E] CORRIDOR 202 [E] VESTIBULE 201 205 203 206 [E] CORRIDOR 204 204 42" H. GLASS GUARDRAIL BY 'CL LAURENCE' [OR SIM];PHASE 2 NEW DOOR TO ROOF DECK TO MATCH EXISTING WINDOW SYSTEM [FINAL LOCATION TBD]NEW HYDRONIC SNOW MELT SYSTEM EMBEDDED WITHIN CONCRETE ROOF TOPPING SLAB
193 EAST GORE CREEK DRIVE VAIL, CO 81657 DRB & PEC 2012.06.25 GORE CREEK TENANT RENOVATION REVISIONS 2012.07.09 1 REVISIONS 2012.07.16 2 120600 2012.06.25 DHS SB NORTH ELEVATION [EXISTING]A2.1 NORTH BUILDING ELEVATION [EXISTING]1/4"=1'-0"8'4'2'0 DASHED CALL OUT INDICATES PORTION OF EXISTING BUILDING TO BE RENOVATED
193 EAST GORE CREEK DRIVE VAIL, CO 81657 DRB & PEC 2012.06.25 GORE CREEK TENANT RENOVATION REVISIONS 2012.07.09 1 REVISIONS 2012.07.16 2 120600 2012.06.25 DHS SB EAST ELEVATION [EXISTING]A2.2 EAST BUILDING ELEVATION [EXISTING]1/4"=1'-0"8'4'2'0 DASHED CALL OUT INDICATES PORTION OF EXISTING BUILDING TO BE RENOVATED [E] MECHANICAL SCREEN TO REMAIN NOTE :ALL EXISTING MECHANICAL EQUIPMENT TO BE FIELD VERIFIED.[E] EXHAUST FAN TO BE REMOVED [E] EXHAUST FAN TO BE REPLACED [E] GREASE DUCT [E] MAKE-UP AIR UNIT [E] EXHAUST FAN [E] MECHANICAL LOUVER TO REMAIN
193 EAST GORE CREEK DRIVE VAIL, CO 81657 DRB & PEC 2012.06.25 GORE CREEK TENANT RENOVATION REVISIONS 2012.07.09 1 REVISIONS 2012.07.16 2 120600 2012.06.25 DHS SB SOUTH ELEVATION [EXISTING]A2.3 SOUTH BUILDING ELEVATION [EXISTING]1/4"=1'-0"8'4'2'0
193 EAST GORE CREEK DRIVE VAIL, CO 81657 DRB & PEC 2012.06.25 GORE CREEK TENANT RENOVATION REVISIONS 2012.07.09 1 REVISIONS 2012.07.16 2 120600 2012.06.25 DHS SB WEST ELEVATION [EXISTING]A2.4 WEST ELEVATION [EXISTING]1/4"=1'-0"8'4'2'0 DASHED CALL OUT INDICATES EXISTING PORTION OF EXISTING BUILDING TO BE RENOVATED EXISTING DOWNSPOUT TO REMAIN EXISTING ROOF STRUCTURE TO REMAIN
2'-0"8'-0"NEW CONSTRUCTION NEW CONSTRUCTION EXISTING BUILDING EXISTING BUILDING 5'-6"3'-6"NEW PHASE 1 PHASE 2 3'-0" [MAX]4'-0" [MAX]193 EAST GORE CREEK DRIVE VAIL, CO 81657 DRB & PEC 2012.06.25 GORE CREEK TENANT RENOVATION REVISIONS 2012.07.09 1 REVISIONS 2012.07.16 2 120600 2012.06.25 DHS SB NORTH ELEVATION [NEW]A2.5 NORTH BUILDING ELEVATION [NEW]1/4"=1'-0"8'4'2'0 ELEVATION KEY NOTES:NEW DARK BRONZE ALUMINUM & GLASS FOLDING DOOR BY LA CANTINA [SEE GEN NOTES]1 NEW BLACKENED STEEL WALL PANEL 2 NEW DOUGLAS FIR PLANK SIDING [STAINED &SEALED]3 NEW BLACKENED STEEL WIDE FLANGE COLUMN 4 NEW FRAMELESS GLASS ENTRY DOOR [BY DORELCO OR SIM]5 NEW PAINTED WOOD OR FIBER CEMENT BOARD FASCIA 6 EXISTING STUCCO WALL SYSTEM 7 EXISTING WINDOW SYSTEM 8 EXISTING PAINTED EXTERIOR STAIRS 10 11 12 13 NEW DOUGLAS FIR PLANK SOFFIT [STAINED &SEALED]NEW STONE VENEER WALL PANEL EXISTING PAINTED WOOD FASCIA LIGHT FIXTURE LEGEND NEW WALL SURFACE MOUNTED DARK BRONZE ALUMINUM UP/DOWN LIGHT;MODEL# HL-374-2X-AA-120 BY HEVI-LITE A NEW DARK BRONZE ALUMINUM GROUND MOUNTED UP ACCENT LIGHT;MODEL# HL-387-AA-120 BY HEVI-LITE [FOR SIGNAGE ILLUMINATION]B NEW DARK BRONZE ALUMINUM CEILING RECESSED DOWN LIGHT;MODEL# 102050130 BY RICHELIEU C NEW DE-MOUNTABLE 36" H. PAINTED STL PATIO GUARDRAIL TO ALIGN W/ VERTICAL DOOR FRAMES [TYP]9 14 EXISTING EXPOSED STEEL COLUMN NEW WALL SURFACE MOUNTED DARK BRONZE ALUMINUM DOWN LIGHT;MODEL# HL-340-AA-12-LA BY HEVI-LITE D 1 1 1 5 3 B 2 2 2 6 2 4 10 11 13 12 14 14 A D D C C 8 9 9 7 STEEL PLATE DOOR GENERAL NOTES:1. EXTERIOR GLASS DOOR MANUFACTURER AND TYPE IS STILL BEING DETERMINED. ALTERNATE TYPE AND MANUFACTURER MAY INCLUDE: SLIDING POCKET DOORS BY 'FLEETWOOD' [OR SIM.]2. ALTERNATE EXTERIOR DOOR OPTIONS WILL REMAIN CONSISTENT WITH FINISH, GLAZING PATTERN AND PROPORTION SHOWN IN NEW PROPOSED NORTH BUILDING ELEVATION.TYPICAL PATIO GUARDRAIL DETAIL 1/2"=1'-0"4'2'1'0 1-1/2" DIA ROUND STEEL PIPE [TOP &BOTTOM RAIL]1/2 "x 1-1/4" STEEL BAR 1/2 "x1/2" VERTICAL STEEL BAR @ MIDSPAN 2" DIA. GALVANIZED STEEL PIPE SLEEVE FOR BALUSTERS [MIN 6" EMBEDMENT]MAX 12" RETURN EXTENSION AT CORNERS ALIGN CENTER OF BALUSTERS W/EXTERIOR DOOR FRAME PATTERN [TYP]NEW [PHASE 2] GLASS GUARDRAIL BY CL LAURENCE OR SIM [PHASE 2]
NEW CONSTRUCTION EXISTING BUILDING NEW CONSTRUCTION EXISTING BUILDING 4'-7"2'-0"8'-0"PHASE 1 NEW PHASE 2 193 EAST GORE CREEK DRIVE VAIL, CO 81657 DRB & PEC 2012.06.25 GORE CREEK TENANT RENOVATION REVISIONS 2012.07.09 1 REVISIONS 2012.07.16 2 120600 2012.06.25 DHS SB EAST ELEVATION [NEW]A2.6 EAST BUILDING ELEVATION [NEW]1/4"=1'-0"8'4'2'0 ELEVATION KEY NOTES:NEW DARK BRONZE ALUMINUM & GLASS FOLDING DOOR BY LA CANTINA [SEE GEN NOTES]1 NEW BLACKENED STEEL WALL PANEL 2 NEW DOUGLAS FIR PLANK SIDING [STAINED &SEALED]3 NEW BLACKENED STEEL WIDE FLANGE COLUMN 4 NEW FRAMELESS GLASS ENTRY DOOR [BY DORELCO OR SIM]5 NEW PAINTED WOOD OR FIBER CEMENT BOARD FASCIA 6 EXISTING STUCCO WALL SYSTEM 7 EXISTING WINDOW SYSTEM 8 EXISTING PAINTED EXTERIOR STAIRS 10 11 12 13 NEW DOUGLAS FIR PLANK SOFFIT [STAINED &SEALED]NEW STONE VENEER WALL PANEL EXISTING PAINTED WOOD FASCIA LIGHT FIXTURE LEGEND NEW WALL SURFACE MOUNTED DARK BRONZE ALUMINUM UP/DOWN LIGHT;MODEL# HL-374-2X-AA-120 BY HEVI-LITE A NEW DARK BRONZE ALUMINUM GROUND MOUNTED UP ACCENT LIGHT;MODEL# HL-387-AA-120 BY HEVI-LITE [FOR SIGNAGE ILLUMINATION]B NEW DARK BRONZE ALUMINUM CEILING RECESSED DOWN LIGHT;MODEL# 102050130 BY RICHELIEU C NEW DE-MOUNTABLE 36" H. PAINTED STL PATIO GUARDRAIL TO ALIGN W/ VERTICAL DOOR FRAMES [TYP]9 14 EXISTING EXPOSED STEEL COLUMN NEW WALL SURFACE MOUNTED DARK BRONZE ALUMINUM DOWN LIGHT;MODEL# HL-340-AA-12-LA BY HEVI-LITE D 10 11 14 12 A 7 6 13 2 10 11 NEW MECHANICAL & LOUVER SCREEN TO MATCH EXISTING AT NEW MAKE-UP AIR UNIT [E] MECHANICAL SCREEN TO REMAIN NOTE :ALL EXISTING MECHANICAL EQUIPMENT TO BE FIELD VERIFIED.[E] FAN UNIT [E] GREASE DUCT [E] MAKE-UP AIR UNIT [E] EXHAUST FAN 10 10 9 NEW [PHASE 2] GLASS GUARDRAIL BY CL LAURENCE [OR SIM]
193 EAST GORE CREEK DRIVE VAIL, CO 81657 DRB & PEC 2012.06.25 GORE CREEK TENANT RENOVATION REVISIONS 2012.07.09 1 REVISIONS 2012.07.16 2 120600 2012.06.25 DHS SB SOUTH ELEVATION [NEW]A2.7 SOUTH BUILDING ELEVATION [NEW]1/4"=1'-0"8'4'2'0 ELEVATION KEY NOTES:NEW DARK BRONZE ALUMINUM & GLASS FOLDING DOOR BY LA CANTINA [SEE GEN NOTES]1 NEW BLACKENED STEEL WALL PANEL 2 NEW DOUGLAS FIR PLANK SIDING [STAINED &SEALED]3 NEW BLACKENED STEEL WIDE FLANGE COLUMN 4 NEW FRAMELESS GLASS ENTRY DOOR [BY DORELCO OR SIM]5 NEW PAINTED WOOD OR FIBER CEMENT BOARD FASCIA 6 EXISTING STUCCO WALL SYSTEM 7 EXISTING WINDOW SYSTEM 8 EXISTING PAINTED EXTERIOR STAIRS 10 11 12 13 NEW DOUGLAS FIR PLANK SOFFIT [STAINED &SEALED]NEW STONE VENEER WALL PANEL EXISTING PAINTED WOOD FASCIA LIGHT FIXTURE LEGEND NEW WALL SURFACE MOUNTED DARK BRONZE ALUMINUM UP/DOWN LIGHT;MODEL# HL-374-2X-AA-120 BY HEVI-LITE A NEW DARK BRONZE ALUMINUM GROUND MOUNTED UP ACCENT LIGHT;MODEL# HL-387-AA-120 BY HEVI-LITE [FOR SIGNAGE ILLUMINATION]B NEW DARK BRONZE ALUMINUM CEILING RECESSED DOWN LIGHT;MODEL# 102050130 BY RICHELIEU C NEW DE-MOUNTABLE 36" H. PAINTED STL PATIO GUARDRAIL TO ALIGN W/ VERTICAL DOOR FRAMES [TYP]9 14 EXISTING EXPOSED STEEL COLUMN NEW WALL SURFACE MOUNTED DARK BRONZE ALUMINUM DOWN LIGHT;MODEL# HL-340-AA-12-LA BY HEVI-LITE D [E] MECHANICAL SCREEN TO REMAIN NOTE :ALL EXISTING MECHANICAL EQUIPMENT TO BE FIELD VERIFIED.[E] MECHANICAL LOUVER TO REMAIN NEW MECHANICAL LOUVER FOR MAKE UP AIR UNIT
NEW CONSTRUCTION EXISTING BUILDING TO REMAIN NEW CONSTRUCTION EXISTING BUILDING TO REMAIN 8'-0"2'-0"NEW PHASE 2 PHASE 1 193 EAST GORE CREEK DRIVE VAIL, CO 81657 DRB & PEC 2012.06.25 GORE CREEK TENANT RENOVATION REVISIONS 2012.07.09 1 REVISIONS 2012.07.16 2 120600 2012.06.25 DHS SB WEST ELEVATION [NEW]A2.8 WEST BUILDING ELEVATION [NEW]1/4"=1'-0"8'4'2'0 ELEVATION KEY NOTES:NEW DARK BRONZE ALUMINUM & GLASS FOLDING DOOR BY LA CANTINA [SEE GEN NOTES]1 NEW BLACKENED STEEL WALL PANEL 2 NEW DOUGLAS FIR PLANK SIDING [STAINED &SEALED]3 NEW BLACKENED STEEL WIDE FLANGE COLUMN 4 NEW FRAMELESS GLASS ENTRY DOOR [BY DORELCO OR SIM]5 NEW PAINTED WOOD OR FIBER CEMENT BOARD FASCIA 6 EXISTING STUCCO WALL SYSTEM 7 EXISTING WINDOW SYSTEM 8 EXISTING PAINTED EXTERIOR STAIRS 10 11 12 13 NEW DOUGLAS FIR PLANK SOFFIT [STAINED &SEALED]NEW STONE VENEER WALL PANEL EXISTING PAINTED WOOD FASCIA LIGHT FIXTURE LEGEND NEW WALL SURFACE MOUNTED DARK BRONZE ALUMINUM UP/DOWN LIGHT;MODEL# HL-374-2X-AA-120 BY HEVI-LITE A NEW DARK BRONZE ALUMINUM GROUND MOUNTED UP ACCENT LIGHT;MODEL# HL-387-AA-120 BY HEVI-LITE [FOR SIGNAGE ILLUMINATION]B NEW DARK BRONZE ALUMINUM CEILING RECESSED DOWN LIGHT;MODEL# 102050130 BY RICHELIEU C NEW DE-MOUNTABLE 36" H. PAINTED STL PATIO GUARDRAIL TO ALIGN W/ VERTICAL DOOR FRAMES [TYP]9 14 EXISTING EXPOSED STEEL COLUMN NEW WALL SURFACE MOUNTED DARK BRONZE ALUMINUM DOWN LIGHT;MODEL# HL-340-AA-12-LA BY HEVI-LITE D 10 10 13 11 D 6 EXISTING DOWNSPOUT TO REMAIN NEW ROOFING MEMBRANE AND FASCIA TO MATCH RENOVATON RELOCATE [E] DOWNSPOUT W/NEW COLLECTION BOX [E] WOOD FENCE TO REMAIN NEW 24x12 METAL LOUVER GENERAL EXHAUST [APPROXIMATE LOCATION SHOWN]9 NEW [PHASE 2] GLASS GUARDRAIL BY CL LAURENCE [OR SIM]
View of Existing North Exterior Elevation 193 EAST GORE CREEK DRIVE VAIL, CO 81657 DRB & PEC 2012.06.25 GORE CREEK TENANT RENOVATION REVISIONS 2012.07.09 1 REVISIONS 2012.07.16 2 120600 2012.06.25 DHS SB EXISTING PHOTOS A3.0 View of Existing Building From NorthEast View of Existing Building From NorthWest View of Existing Building at Sweet Basil Egress Stair
ACCENT FEATURES WALLS GLASS / WINDOWS BUILDING EXTERIOR WALLS:BLUED STEEL PLATE WITH CLEAR MATTE SEALER FINISH DETAIL: 4'x8' [MAX] RAIN SCREEN PANELS COLOR: DARK GRAY TONES CLEAR, DOUBLE-PANED,LOW-EMMITTING INSULATED GLASS COLOR: CLEAR ALUMINUM STOREFRONT & FOLDING GLASS DOOR FRAMES:COLOR: ANODIZED DARK BRONZE MECHANICAL SCREEN WALLS [AS NECESSARY]:VERTICAL WOOD OR FIBER CEMENT PANEL [TO MATCH EXISTING]COLOR: OFF-WHITE OR CREAM [MATCH EXISTING]193 EAST GORE CREEK DRIVE VAIL, CO 81657 DRB & PEC 2012.06.25 GORE CREEK TENANT RENOVATION REVISIONS 2012.07.09 1 REVISIONS 2012.07.16 2 120600 01/19/12 DHS SB MATERIAL PALETTE A4.0 STONE ACCENT WALL:PANELIZED STONE VENEER; TYPE: TBD COLOR: NEUTRAL/LIGHT GREY (BETTER INDICATED BY RENDERINGS)NOTE: THIS MATERIAL IS INTENDED TO BE A BACKDROP FOR SMALL LANDSCAPE FEATURE OR EXTERIOR SCULPTURE BUILDING EXTERIOR WALLS & SOFFIT:STAINED AND SEALED WOOD PLANK DETAIL: 4" WIDE COLOR/TYPE: DOUGLAS FIR OR CEDAR ROOF & FASCIA PAINTED WOOD OR CEMENT BOARD FASCIA:FASCIA TO MATCH EXISTING COLOR: SW7048 "URBANE BRONZE" BY SHERWIN WILLIAMS [OR SIM]*NOTE: PAINT COLOR MAY VARY SLIGHTLY FROM ORIGINAL SELECTION PENDING SITE MOCK-UP APPROVAL BY OWNER.ROOFING:SHEET MEMBRANE ROOFING [BY CARLISLE ,FIRESTONE OR SIM.]APPLY 3" LAYER OF CONCRETE TOPPING OVERLAY WITH INTEGRAL HYDRONIC SNOWMELT SYSTEM COLOR: NEUTRAL GREY [TBD]
View of Exterior from NorthEast View of North Exterior Elevation Detailed View of Entry 193 EAST GORE CREEK DRIVE VAIL, CO 81657 DRB & PEC 2012.06.25 GORE CREEK TENANT RENOVATION REVISIONS 2012.07.09 1 REVISIONS 2012.07.16 2 120600 2012.06.25 DHS SB RENDERINGS A5.0 View of Exterior from NorthWest NOTE: 3D RENDERINGS ARE SHOWN AS A MOCK-UP REPRESENTATION FOR MATERIALS, FINISHES AND COLOR SELECTIONS ONLY. ACTUAL COLORS AND FINISHES MAY VARY SLIGHTLY FROM THOSE REPRESENTED HERE.NOTE: RESTAURANT SIGNAGE LOCATION;APPROVAL PENDING SEPARATE SUBMITTAL PROCESS NOTE: RESTAURANT OUTDOOR PATIO LEASE EXPANSION PENDING SEPARATE TOWN AGREEMENT NOTE: RESTAURANT LOGO [TBD] LASER ETCHED OR SANDBLASTED ON DOOR SURFACE.NOTE: EXTERIOR ALUMINUM DOOR SYSTEM TYPE &MANUFACTURER TBD NOTE: GLASS GUARDRAIL AT ROOF DECK BY CL LAURENCE OR SIM [PHASE 2]NOTE: GLASS GUARDRAIL AT ROOF DECK BY CL LAURENCE OR SIM [PHASE 2]NOTE: GLASS GUARDRAIL AT ROOF DECK BY CL LAURENCE OR SIM [PHASE 2]