Loading...
HomeMy WebLinkAboutB12-0289 PLANS approvedReceived June 29, 2012 RECEI V V ED Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By m at 1:50 pm, Jul 19, 2012 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By m at 1:50 pm, Jul 19, 2012 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By m at 1:50 pm, Jul 19, 2012 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By m at 1:50 pm, Jul 19, 2012 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By m at 1:51 pm, Jul 19, 2012 UNIT TAG MANUFACTURER & MODEL NODESCRIPTIONWASTEVENT COLD WATER HOT WATER REMARKS LVLAVATORY1-1/2"1-1/2"1/2"1/2"-WCWATER CLOSET3"2"1/2"--SHSHOWER2"1-1/2"3/4"3/4"-COZURN ZN1400CLEAN OUTVARIES----WCOZURN Z1441WALL CLEAN OUTVARIES----PLUMBING FIXTURE CONNECTION SCHEDULE PLUMBING FIXTURE SPECIFICATIONS & HARDWARE SELECTION TO BE BY ARCHITECT. FIXTURE ALLOWANCE NOT TO EXCEED THE ESTABLISHED BUDGET.CAP (BTU/LF)GPM EWT (°F)LWT (°F)WPD (FT)MOUNTING HEIGHT (IN. AFF)HEIGHTWIDTH BBSTERLING - CLCU75SEE PLANSSEE PLANS2 x 2505201.0180160-1 7/89 1/83 3/8 COORDINATE THE ENCLOSURE FOR EACH CONDO TO MATCH THE EXISTING ENCLOSURES.LOCATION ELEMENT SIZE (INxIN)FINS PER FOOT HEATING DATA SERVICE HYDRONIC BASEBOARD HEATER SCHEDULE OR EQUIVALENT UNIT TAG MANUFACTURER & MODEL NO.COVER DATA REMARKS POWER EF-1PANASONIC FV-11VQ5--CEILING901,1610.2520.7 W0.510.4INTEGRAL BACKDRAFT DAMPER, INTERLOCK WITH WALL SWITCH 120 / 1 / 60 SERVICE TOTAL CFM FAN RPM ESP (IN)ELECTRICAL DATA V / PH / Hz LOCATION NOISE LEVEL (SONES)OPER. WT. (LBS)TYPE EXHAUST FAN SCHEDULE OR EQUIVALENT UNIT TAG MANUFACTURER & MODEL NO.REMARKS Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By m at 1:51 pm, Jul 19, 2012 PROJECT: LIONSQUARE LODGE SOUTH INFILLENGINEER:DCF PROJECT #: 11056 VOLTAGE:120/208V, 1P, 3W MOUNTING: RECESSED MAINS:100A MLO TYPE: SQUARE D QO (NEW)AIC:EXISTING PHASE PHASE DESCRIPTION A BBKR PCIRCIR P BKR A BDESCRIPTION ENTRY BEDROOM #11280 20112120750 INSTA HOT RANGE 400050234120 425POWDER ROOM "4000 561201080 LIVING ROOM OUTLETS KITCHEN LIGHTS 60020178120 1500DINING ROOM KITCHEN OUTLET #11500 201910120600 LIVING ROOM LIGHTS BEDROOM #2 12802011112120 525BATH #1 (N) BEDROOM/LR REC(9)1620 2011314120225 (N) BATHROOM FAN/REC(1)(N) BED/BATH LIGHTING 6002011516 0SPACE SPACE0 17180 SPACE SPACE 01920 0SPACE SPACE0 21220 SPACE SPACE 02324 0SPACE LOAD CALCULATION SUMMARYNOTE: PROVIDE ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION-TYPE CIRCUIT BREAKERS FOR BRANCH CIRCUITS SUPPLYING ALL 120V POWER OUTLETS EXCEPT IN KITCHENS, BATHROOMS, AND GARAGES.CALCULATED POWER FACTOR:ALL EXISTING CIRCUITS THIS UNIT SHALL BE RE-FED WITH NEW BREAKERS IN NEW PANEL.1.00 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS APPLIANCES75047504 LIGHTING & RECEPT.1110053583528 MECHANICAL1351146.251 KITCHEN OVEN & DRYER800038640031 TOTAL19985961313163 PANEL UNIT 450 Fixture Type Lamp TypeQuantity Fixture Type Lamp TypeQuantity CINCANDESCENT1ACFL1 C2INCANDESCENT2BCFL1 DCFL1 FCFL1 Incandescent Total:3High-Efficacy Total:4 Percent High-Efficacy:57.14%(must be minimum of 50%)IECC 2009 CALCULATION Incandescent FixturesHigh Efficacy Fixtures Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By m at 1:51 pm, Jul 19, 2012 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By m at 1:51 pm, Jul 19, 2012 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By m at 1:51 pm, Jul 19, 2012 UNIT TAG MANUFACTURER & MODEL NODESCRIPTIONWASTEVENT COLD WATER HOT WATER REMARKS LVLAVATORY1-1/2"1-1/2"1/2"1/2"-WCWATER CLOSET3"2"1/2"--SHSHOWER2"1-1/2"3/4"3/4"-CWBCLOTHESWASHER BOX2"1-1/2"3/4"3/4"-COZURN ZN1400CLEAN OUTVARIES----WCOZURN Z 1441WALL CLEAN OUTVARIES----PLUMBING FIXTURE CONNECTION SCHEDULE PLUMBING FIXTURE SPECIFICATIONS & HARDWARE SELECTION TO BE BY ARCHITECT. FIXTURE ALLOWANCE NOT TO EXCEED THE ESTABLISHED BUDGET.CAP (BTU/LF)GPM EWT (°F)LWT (°F)WPD (FT)MOUNTING HEIGHT (IN. AFF)HEIGHTWIDTH BBSTERLING - CLCU75SEE PLANSSEE PLANS2 x 2505201.0180160-1 7/89 1/83 3/8 COORDINATE THE ENCLOSURE FOR EACH CONDO TO MATCH THE EXISTING ENCLOSURES.LOCATION ELEMENT SIZE (INxIN)FINS PER FOOT HEATING DATA SERVICE HYDRONIC BASEBOARD HEATER SCHEDULE OR EQUIVALENT UNIT TAG MANUFACTURER & MODEL NO.COVER DATA REMARKS POWER EF-1PANASONIC FV-11VQ5BATHBATHCEILING901,1610.2520.7 W0.510.4INTEGRAL BACKDRAFT DAMPER, INTERLOCK WITH WALL SWITCH 120 / 1 / 60 SERVICE TOTAL CFM FAN RPM ESP (IN)ELECTRICAL DATA V / PH / Hz LOCATION NOISE LEVEL (SONES)OPER. WT. (LBS)TYPE EXHAUST FAN SCHEDULE OR EQUIVALENT UNIT TAG MANUFACTURER & MODEL NO.REMARKS Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By m at 1:51 pm, Jul 19, 2012 PROJECT: LIONSQUARE LODGE SOUTH INFILLENGINEER:DCF PROJECT #: 11056 VOLTAGE:120/208V, 1P, 3W MOUNTING: RECESSED MAINS:100A MLO TYPE: SQUARE D QO (NEW)AIC:EXISTING PHASE PHASE DESCRIPTION A BBKR PCIRCIR P BKR A BDESCRIPTION EAST BEDROOM REC (5)900 20112120230 EAST BATHROOM KITCHEN REC 150020134120 1400LR & WEST BR LIGHTS BATH & KITCHEN LIGHTS1200 201561201500 NORTH KITCHEN REC REFRIGERATOR 100020178250 4000RANGE DISPOSAL1000 2019104000 "MICROWAVE 12002011112120 1440(N) BEDROOM REC(8)(N) BATHROOM FAN/REC(1)225 20113141201000 (N) BED/BATH LIGHTING (N) LAUNDRY REC 15002011516120 1500(N) WASHER SPACE0 17182302500 (N) DRYER SPACE 01920 2500"SPACE0 21220 SPACE SPACE 02324 0SPACE LOAD CALCULATION SUMMARYNOTE: PROVIDE ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION-TYPE CIRCUIT BREAKERS FOR BRANCH CIRCUITS SUPPLYING ALL 120V POWER OUTLETS EXCEPT IN KITCHENS, BATHROOMS, AND GARAGES.CALCULATED POWER FACTOR:ALL EXISTING CIRCUITS THIS UNIT SHALL BE RE-FED WITH NEW BREAKERS IN NEW PANEL.1.00 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS APPLIANCES970047970047 LIGHTING & RECEPT.1080052573028 MECHANICAL951107.51 KITCHEN OVEN & DRYER800038640031 TOTAL2859513821938SEE DEMAND LOAD CALCS PANEL UNIT 550 Quantity Volt-Amps Demand Total (VA)General Dwelling unit Square footage General & Lighting (1st 3 KVA)1322 SF X 3X100%=3966 Kitchen Small Appliances1 EA X1500X100%=1500 Refrigerator1 EA X1200X100%=1200 Dishwasher1 EA X1200X100%=1200 Oven/Range (Re:table220.19)1 EA X8000X100%=8000 Disposal1 EA X1200X100%=1200 Microwave1 EA X1200X100%=1200 Laundry & Spa Appliances Clothes Washer1 EA X1000X100%=1000 Clothes Dryer1 EA X5000X100%=5000 Laundry Receptacle Circuit1 EA X1500X100%=1500 Steam Shower0 EA X7500X100%=0 Jacuzzi Tub0 EA X1200X100%=0 Mechanical Equipment Air Conditioning Units0 EA X4300X100%=0 Humidifiers0 EA X1420X100%=0 Electric In-Floor Heat0 SF X12X100%=0 Electric Baseboard Heat0 LF X250X100%=0 25766 100% of forst 10KVA 10000X100%=10000 40% of remainder 15766X40%=6306 16306 VA 208V, 1-Phase, 3 Wire Service78Amps UNIT 550 Demand Load Calculations (Per NEC Article 220 Parts I-III)Fixture Type Lamp TypeQuantity Fixture Type Lamp TypeQuantity BINCANDESCENT1ACFL2 Incandescent Total:1High-Efficacy Total:2 Percent High-Efficacy:66.67%(must be minimum of 50%)IECC 2009 CALCULATION Incandescent FixturesHigh Efficacy Fixtures Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By m at 1:51 pm, Jul 19, 2012 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By m at 1:51 pm, Jul 19, 2012 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By m at 1:52 pm, Jul 19, 2012 UNIT TAG MANUFACTURER & MODEL NODESCRIPTIONWASTEVENT COLD WATER HOT WATER REMARKS LVLAVATORY1-1/2"1-1/2"1/2"1/2"-WCWATER CLOSET3"2"1/2"--SHSHOWER2"1-1/2"3/4"3/4"-CWBCLOTHESWASHER BOX2"1-1/2"3/4"3/4"-COZURN ZN1400CLEAN OUTVARIES----WCOZURN Z1441WALL CLEAN OUTVARIES----PLUMBING FIXTURE CONNECTION SCHEDULE PLUMBING FIXTURE SPECIFICATIONS & HARDWARE SELECTION TO BE BY ARCHITECT. FIXTURE ALLOWANCE NOT TO EXCEED THE ESTABLISHED BUDGET.CAP (BTU/LF)GPM EWT (°F)LWT (°F)WPD (FT)MOUNTING HEIGHT (IN. AFF)HEIGHTWIDTH BBSTERLING - CLCU75SEE PLANSSEE PLANS2 x 2505201.0180160-1 7/89 1/83 3/8 COORDINATE THE ENCLOSURE FOR EACH CONDO TO MATCH THE EXISTING ENCLOSURES.LOCATION ELEMENT SIZE (INxIN)FINS PER FOOT HEATING DATA SERVICE HYDRONIC BASEBOARD HEATER SCHEDULE OR EQUIVALENT UNIT TAG MANUFACTURER & MODEL NO.COVER DATA REMARKS POWER EF-1PANASONIC FV-11VQ5--CEILING901,1610.2520.7 W0.510.4INTEGRAL BACKDRAFT DAMPER, INTERLOCK WITH WALL SWITCH 120 / 1 / 60 SERVICE TOTAL CFM FAN RPM ESP (IN)ELECTRICAL DATA V / PH / Hz LOCATION NOISE LEVEL (SONES)OPER. WT. (LBS)TYPE EXHAUST FAN SCHEDULE OR EQUIVALENT UNIT TAG MANUFACTURER & MODEL NO.REMARKS Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By m at 1:52 pm, Jul 19, 2012 PROJECT: LIONSQUARE LODGE SOUTH INFILLENGINEER:DCF PROJECT #: 11056 VOLTAGE:120/208V, 1P, 3W MOUNTING: RECESSED MAINS:100A MLO TYPE: SQUARE D QO (NEW)AIC:EXISTING PHASE PHASE DESCRIPTION A BBKR PCIRCIR P BKR A BDESCRIPTION BATH & LV REC1440 20112120360 RIGHT BATH REC COOKTOP 325040234240 3250OVEN "3250 563250 "ENTRY & LEFT BEDROOM 144020178120 900BATH LIGHTING RIGHT BEDROOM1080 201910120600 KITCHEN LIGHTING MICROWAVE 12002011112120 1500KITCHEN REC REFRIGERATOR1000 20113141201000 DISHWASHER (N) BEDROOM REC(6) 10802011516120 1000DISPOSAL (N) BATHROOM FAN/REC(1)225 20117180 SPACE (N) BED/BATH LIGHTING 6002011920120 1500(N) WASHER SPACE0 21222302500 (N) DRYER SPACE 02324 2500"LOAD CALCULATION SUMMARYNOTE: PROVIDE ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION-TYPE CIRCUIT BREAKERS FOR BRANCH CIRCUITS SUPPLYING ALL 120V POWER OUTLETS EXCEPT IN KITCHENS, BATHROOMS, AND GARAGES.CALCULATED POWER FACTOR:ALL EXISTING CIRCUITS THIS UNIT SHALL BE RE-FED WITH NEW BREAKERS IN NEW PANEL.1.00 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS APPLIANCES10700511070051 LIGHTING & RECEPT.918044516325 MECHANICAL45056.250 KITCHEN OVEN & DRYER1300063845041 TOTAL3292515824369 SEE DEMAND LOAD CALCS PANEL UNIT 650 Quantity Volt-Amps Demand Total (VA)General Dwelling unit Square footage General & Lighting (1st 3 KVA)1235 SF X 3X100%=3705 Kitchen Small Appliances1 EA X1500X100%=1500 Refrigerator1 EA X1200X100%=1200 Dishwasher1 EA X1200X100%=1200 Oven/Range (Re:table220.19)2 EA X6500X100%=13000 Disposal1 EA X1200X100%=1200 Microwave1 EA X1200X100%=1200 Laundry & Spa Appliances Clothes Washer1 EA X1000X100%=1000 Clothes Dryer1 EA X5000X100%=5000 Steam Shower0 EA X7500X100%=0 Jacuzzi Tub0 EA X1200X100%=0 Towel Warmer0 EA X800X100%=0 Mechanical Equipment Air Conditioning Units0 EA X4300X100%=0 Humidifiers0 EA X1420X100%=0 Electric In-Floor Heat0 SF X12X100%=0 Electric Baseboard Heat0 LF X250X100%=0 29005 100% of forst 10KVA 10000X100%=10000 40% of remainder 19005X40%=7602 17602 VA 208V, 1-Phase, 3 Wire Service85Amps UNIT 650 Demand Load Calculations (Per NEC Article 220 Parts I-III)Fixture Type Lamp TypeQuantity Fixture Type Lamp TypeQuantity CINCANDESCENT2ACFL1 FINCANDESCENT1BCFL1 DCFL1 Incandescent Total:3High-Efficacy Total:3 Percent High-Efficacy:50.00%(must be minimum of 50%)IECC 2009 CALCULATION Incandescent FixturesHigh Efficacy Fixtures Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By m at 1:52 pm, Jul 19, 2012 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By m at 1:52 pm, Jul 19, 2012