Loading...
HomeMy WebLinkAboutB12-0288 Approved plansPROJECT: LIONSQUARE LODGE SOUTH INFILLENGINEER:DCF PROJECT #: 11056 VOLTAGE:120/208V, 1P, 3W MOUNTING: RECESSED MAINS:70A MLO TYPE: SQUARE D QO (NEW)AIC:EXISTING PHASE PHASE DESCRIPTION A BBKR PCIRCIR P BKR A BDESCRIPTION KITCHEN1500 201121201080 LOFT REC AND LTG DISPOSAL 100020134120 1500REFRIGERATOR KITCHEN1500 201561201080 EXISTING BEDROOM 4 RANGE 400050278 0 SPACE "4000 9101201080 (N) LIVING ROOM REC (6)(N) BEDROOM REC(8) 14402011112120 600(N) BED/BATH/LVG LTG (N) BATH 2 REC(1) & VANITY LT 200 20113141201080 (N)BEDROOM 7 REC (6)(N) BATH 8 REC(1) & VANITY LT 2002011516 0SPACE (N) BATH 6 REC(1) & VANITY LT 200 20117180 SPACE (N) BATH 2 FAN HT 14002011920 0 SPACE (N) BATH 8 FAN HT1400 20121220 SPACE (N) BATH 6 FAN HT 14002012324 0 SPACE LOAD CALCULATION SUMMARYNOTE: PROVIDE ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION-TYPE CIRCUIT BREAKERS FOR BRANCH CIRCUITS SUPPLYING ALL 120V POWER OUTLETS EXCEPT IN KITCHENS, BATHROOMS, AND GARAGES.CALCULATED POWER FACTOR:ALL EXISTING CIRCUITS THIS UNIT SHALL BE RE-FED WITH NEW BREAKERS IN NEW PANEL.0.97 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS APPLIANCES1000510005 LIGHTING & RECEPT.1146055596129 MECHANICAL420024455026 KITCHEN OVEN & DRYER800038640031 TOTAL2466012217911REFERENCE DEMAND LOAD CALCS PANEL UNIT 554 Quantity Volt-Amps Demand Total (VA)General Dwelling unit Square footage970 General & Lighting (1st 3 KVA)1000 SF X 3X100%=3000 General & Lighting (Remainder) SF X 3X35%=0 Kitchen Small Appliances2 EA X1500X35%=1050 Refrigerator1 EA X1000X75%=750 Dishwasher1 EA X1200X75%=900 Oven/Range (Re:table220.19)1 EA X5000X80%=4000 Disposal1 EA X1000X75%=750 Microwave1 EA X1200X75%=900 Laundry & Spa Appliances Clothes Washer0 EA X1000X75%=0 Clothes Dryer0 EA X5000X100%=0 Mechanical Equipment bathroom exhaust fans3 EA X1500X100%=4500 TOTAL 15850 For 208V, 1-Phase, 3 Wire Service15850(VA) /208=76AMPS UNIT 554 Demand Load Calculations (Per NEC Article 220 Parts I-III)Fixture Type Lamp TypeQuantity Fixture Type Lamp TypeQuantity AINCANDESCENT5BCFL3 CCFL2 F CFL3 Incandescent Total:5High-Efficacy Total:8 Percent High-Efficacy:61.54%(must be minimum of 50%)IECC 2009 CALCULATION Incandescent FixturesHigh Efficacy Fixtures UNIT TAG MANUFACTURER & MODEL NODESCRIPTIONWASTEVENT COLD WATER HOT WATER REMARKS LVLAVATORY1-1/2"1-1/2"1/2"1/2"-WCWATER CLOSET3"2"1/2"--SHSHOWER2"1-1/2"3/4"3/4"-COZURN ZN1400CLEAN OUTVARIES----WCOZURN Z1441WALL CLEAN OUTVARIES----PLUMBING FIXTURE CONNECTION SCHEDULE PLUMBING FIXTURE SPECIFICATIONS & HARDWARE SELECTION TO BE BY ARCHITECT. FIXTURE ALLOWANCE NOT TO EXCEED THE ESTABLISHED BUDGET.CAP (BTU/LF)GPM EWT (°F)LWT (°F)WPD (FT)MOUNTING HEIGHT (IN. AFF)HEIGHTWIDTH BBSTERLING - CLCU75SEE PLANSSEE PLANS2 x 2505201.0180160-1 7/89 1/83 3/8 COORDINATE THE ENCLOSURE FOR EACH CONDO TO MATCH THE EXISTING ENCLOSURES.LOCATION ELEMENT SIZE (INxIN)FINS PER FOOT HEATING DATA SERVICE HYDRONIC BASEBOARD HEATER SCHEDULE OR EQUIVALENT UNIT TAG MANUFACTURER & MODEL NO.COVER DATA REMARKS A EF-1PANASONIC FV-11VHL2BATHBATHCEILING901,1610.2512.50.510.4INTEGRAL BACKDRAFT DAMPER, INTERLOCK WITH WALL SWITCH NOISE LEVEL (SONES)OPER. WT. (LBS)TYPE EXHAUST FAN SCHEDULE OR EQUIVALENT UNIT TAG MANUFACTURER & MODEL NO.REMARKS 120 / 1 / 60 SERVICE TOTAL CFM FAN RPM ESP (IN)ELECTRICAL DATA V / PH / Hz LOCATION