Loading...
HomeMy WebLinkAboutB12-0299 Final Air Clearance Report Final Clearance Air Monitoring Report 927 Red Sandstone Rd, Unit 14B, Vail, Colorado 81657 Presented To: Mr. Bob Hamilton Stink, Inc. 2995 South Fox Street Englewood, CO 80110 Performed & Prepared By: Mr. Rich Kreuscher DS Consulting, Inc. PO Box 6864 Avon, CO 81620 (970) 389-3408 Project Details: Project Number: 6089 Conducted: July 11, 2012 2 TABLE OF CONTENTS PROJECT OVERVIEW 1.0 Introduction 2.0 Site Description 3.0 Scope of Work 4.0 Certifications 5.0 Final Visual & Final Clearance Procedures 6.0 Air Sample Analyzation 7.0 Air Sample Results APPENDIX A AMS/Analyst Certificates 3 PROJECT OVERVIEW 1.0 Introduction On July 11, 2012, DS Consulting, Inc. (DSC) conducted a final visual inspection, performed aggressive clearance air monitoring, and analyzed clearance air quality samples via Phase Contrast Microscopy (PCM) for an asbestos abatement project within a portion of the residence located at 927 Red Sandstone Rd, Unit 14B, Vail, Colorado. Stink Inc. Environmental was the General Abatement Contractor (GAC) performing the asbestos abatement within the residence. Mr. Mark Benedict was the GAC supervisor on- site during the final clearance. 2.0 Site Description The residence is a wood-framed, single-level, single-family residence in a multi-unit building. 3.0 Scope of Work The asbestos abatement activities were conducted to remove approximately 800 ft2 of asbestos- containing surfacing texture from a single full containment encompassing the main level kitchen, living room and hallway. This asbestos abatement project was a fully permitted project with the Colorado Department of Public Health and Environment (CDPHE). 4.0 Certifications The final visual inspection, the aggressive clearance air monitoring, and the PCM air sample analyzation were conducted by Mr. Rich Kreuscher with DSC. Mr. Kreuscher is a CDPHE certified Air Monitoring Specialist (AMS); having certification number 15812 and a NIOSH 582 certified analyst. DSC is a CDPHE certified Asbestos Consulting Firm, Registration No. 14912 and a participant in the Industrial Hygiene Proficiency Analytical Testing (IHPAT) program with laboratory ID No. 188987 maintaining a rating of Proficient. 5.0 Final Visual & Final Clearance Procedures Prior to the collection of final clearance air samples, a final visual inspection was conducted to ensure all of the visual requirements of CDPHE’s Regulation 8, Part B – Asbestos, were met. Once the abatement area passed the final visual inspection, DSC collected final clearance air samples from multiple locations within the containment. Following the collection of the final clearance air samples, the samples were analyzed - along with sample blanks - to determine the airborne fiber concentrations. The air samples were collected at an average flow rate 15.0 liters per minute (L/m) using Thomas high- volume pumps with a minimum of 1,200 liters being collected. Flow rates were collected at the beginning and at the end of the sampling period utilizing an airflow rotameter calibrated a gainst a primary-flow calibration instrument. Start times and stop times were recorded for all sampling periods. 4 6.0 Air Sample Analyzation The final clearance PCM samples were collected on 25-millimeter (mm) mixed-cellulose, ester-membrane filters with a 0.8-micron pore size and an effective collection area of 385 mm. All filters were pre- assembled by the manufacturer in three-stage, conductive sampling cassettes with extension cowls. A field blank and lab blank were also collected and analyzed along with the clearance samples. 7.0 Air Sampling Results The abatement project passed the final visual inspection and t he analytical results of all final clearance samples collected were below CDPHE’s clearance criteria of 0.01 fibers/cubic centimeter (f/cc). This amount, quantified as “fibers”, is not specific to asbestos fibers; therefore, all fibers that meet the counting criteria are counted as asbestos fibers. If the total fiber count is less than 0.01 fibers/cubic centimeter (f/cc), it is known that the total asbestos fiber count is also less than 0.01 fibers/cubic centimeter (f/cc). Please see Table 1 for analytical data. TABLE 1 Sample ID Sample Location Collection Rate (Liter/Minute) Collection Time (Minutes) Air Volume (Liters) Fields Analyzed Reporting Limit (Fibers/cc) Fiber Count Fiber Concentration (Fibers/cc) CL1 Main Level Kitchen, Middle 15.0 90 1350 100 0.002 6.0 0.002 CL2 Main Level Kitchen, West Side 15.0 90 1350 100 0.002 5.0 0.002 CL3 Main Level Hallway, Middle 15.0 90 1350 100 0.002 4.5 BRL CL4 Main Level Living Room, North Side 15.0 90 1350 100 0.002 3.5 BRL CL5 Main Level Living Room, South Side 15.0 90 1350 100 0.002 3.0 BRL LB Lab Blank N/A N/A N/A 100 0.000 0.0 0.000 FB Field Blank N/A N/A N/A 100 0.000 0.0 0.000 *Sample analysis has been blank corrected BRL = Below Reporting Limit CBR = Cannot Be Read APPENDIX A - AMS/ANALYST CERTIFICATIONS