HomeMy WebLinkAboutDRB120327y { I
Project Name: TIMBER RIDGE BUILDINGS K &L DRB Number: DRB120327
Project Description:
REPAIR MODIFICATIONS TO EXISTING DECK WALKWAY STRUCTURE DUE TO WEAR AND TEAR.
BUILDINGS K AND L. SAME -FOR -SAME REPAIR AND REPAINT.
Participants:
OWNER TIMBER RIDGE AFFORDABLE HOUS 07/26/2012
IN CARE OF NAME FINANCE DIRECTOR
75 S FRONTAGE RD W
VAIL
CO 81657
CONTRACTOR RECONSTRUCTION EXPERTS INC 07/26/2012
DAVE ORNBERG
5310 VIVIAN STREET
ARVADA
CO 80002
License: C000003273
APPLICANT TIMBER RIDGE AFFORDABLE HOUS 07/26/2012
IN CARE OF NAME FINANCE DIRECTOR
75 S FRONTAGE RD W
VAIL
CO 81657
Project Address: 1280 N FRONTAGE RD W VAIL
Phone: 303-783-2562
Location: BUILDINGS K AND L.
Legal Description: Lot: C -1, Block: A TO Subdivision: LION'S RIDGE FIL. 1
Parcel Number: 2103 - 121 - 0500 -8
Comments: See conditions
BOARD /STAFF ACTION
Motion By: Action: STAFFAPP
Second By:
Vote: Date of Approval: 07/31/2012
Conditions:
Cond: 8
(PLAN): No changes to these plans may be made without the written consent of Town of
Vail staff and /or the appropriate review committee(s).
Cond: 0
(PLAN): DRB approval does not constitute a permit for building. Please consult with
Town of Vail Building personnel prior to construction activities.
Cond: 201
(PLAN): DRB approval shall not become valid for 20 days following the date of
approval, pursuant to the Vail Town Code, Chapter 12 -3 -3: APPEALS.
Cond: 202
(PLAN): Approval of this project shall lapse and become void one (1) year following
the date of final approval, unless a building permit is issued and construction is
commenced and is diligently pursued toward completion.
Planner: Warren Campbell DRB Fee Paid: $250.00
TOWN OF VAI
JUL 2 4 201
TOWN OF VAIL
Department of Community Development
75 South Frontage Road
Vail, CO 81657
Tel: 970479 -2128
www.vailgov.com
Development Review Coordinator
Application for Design Review
Minor Exterior Alteration
General Information: This application is required for all proposals involving minor changes to buildings and site improve-
ments, such as roofing, painting, window additions, landscaping, fences, retaining walls, etc. Applicable Vail Town
Code sections can be found at www.vailgov.com under Vail Information — Town Code Online. All projects requiring de-
sign review must receive approval prior to submitting a building permit application. An application for Design Review
cannot be accepted until all required information is received by the Community Development Department, as outlined in
the submittal requirements. The project may also need to be reviewed by the Town Council and /or the Planning and
Environmental Commission. Design review approval expires one year from the date of approval, unless a building per-
mit is issued and construction commences.
FeR
Fee: $250 r Multi - Family /Commercial !7"
for Single Family /Duplex
Single Family _❑� Duplex Multi - Family
❑ Commercial
Description of the Request: qtr e t)& c eo&ks y eKt 5nk� oxa- tk�Ak1�W'^'k--
Ser J c �C(► NJ C kv WPA\r i kArA,l-- b %)tk .kAe, 14 ��� L,
Physical Address: 1Z O /V lkl . Vk,( I(Cj . f3( (oS-7
Parcel Number: Zj D 1 L \bSUDg (Contact Eagle Co. Assessor at 970 - 328 -8640 for parcel no.)
tAo/),j R.Ajp, F�IINS 1 QiDIX
Property Owner: 1 Ak �k t Z)Kb (_ 4m)"J( UL_(1 . �' 1- S
Mailing Address: MtQ N oa.�g t�k W, u'J, W. 6[65"1
..Owner's Signature:
Phone: Al - ylt< - fob S1
r a5 4�c
v
Primary Contact/ Owner Representative: ('kr ,S fi�t�Ylr�� iDrJ
Mailing Address: LObb 0 C"n'� eo k Lo • �C A (,D• luo.
Phone: q10-411P-05i
E -Mail: C�� �S ��+� +n4�o�► Q(or�nnrc,��t fie. Fax: CiTb tilb - 2F333
how.
For Office Use Only:
Cash_ CC: Visa / MC Last 4 CC # Exp. Date: Auth # Check #
Fee Paid: IdA I V6 0 Received From:
Meeting Date: DRB No.:
Planner: Project No:
Zoning: Land Use:
Location of the Proposal: Lot: ` S Block: Subdivision: L1pA)1S 'Rt f'A E 5VlL.JMQ
TOWN OF VAIL
JOINT PROPERTY OWNER
WRITTEN APPROVAL LETTER
The applicant must submit written joint property owner approval for applications affecting shared ownership properties
such as duplex, condominium, and multi- tenant buildings. This form, or similar written correspondence, must be com-
pleted by the adjoining duplex unit owner or the authorized agent of the home owner's association in the case of a con-
dominium or multi- tenant building. All completed forms must be submitted with the applicants completed application.
I, (print name) 0 q'�_] S at Ai 6-M&) , a joint owner, or authority of the association,
of property located at 1 t60 N f2� provide this letter as written
approval of the plans dated i ? `l l z which have been submitted to the
Town of Vail Community Development Department for the proposed improvements to be completed at the address not-
ed above. I understand that the proposed improvements include:
car �s•%anS A4 A C1ciShr�ti �� w�11Gw�t ��L%J �� ��E
Additionally, please check the statement below which is most applicable to you:
I understand that minor modifications may be made to the plans over the course of the review process to ensure compli-
ance ith he Town's applicable codes and regulations.
(Initial here)
I understand that all modifications, minor or otherwise, which are made to the plans over the course of the review pro-
cess, be brought to my attention by the applicant for additional approval before undergoing further review by the Town.
(Initial here)
Property Information
Property Address
U160 /J 9 . (, i k4"' 1 (C - bS
Parcel #
0 b
Legal Description
L\on15 ��� �1 `un1 1 30C— L LD� 1 -Lj
Development Site Area
sq ft
Primary sq ft
acres
buildable sq
ft
Secondary sq ft
Zone District / SDD #
Hazard Zones
Sections 12 -21 & 14 -7
SnowAvolonche
❑ High Severity Moderate Severity E] N /A
Debris Flow
Flow
❑ High g ❑Moderate Flow []High Avalanche N/A
Rock fall
E] High Severity Medium Severity []N/A
Excessive Slopes
E] >_30% ❑ N/A
Floodploin I
E] 100 year flood plain ❑ Floodway [] Wetlands E] N/A
Creeks, Streams
Section 12 -14 -17
Gore Creek ❑ on site ❑ adjacent to site ❑ N/A
Other tributary: Don site E] adjacent to site ❑ N/A
Project Information
Project Description
Development Standards
Allowed
Existing
Proposed
Gross Residential Floor Area
(maximum)
Chapter 12 -15
Primary sq ft
Secondary sq ft
EHU sq ft
TOTAL sq ft
[1250 Addition o Interior Conversion
Credits:
Setbacks (minimum)
Section 14 -10 -4
Front ft
Side ft
Side ft
Rear ft
Watercourse ft
Site Coverage (maximum)
see definition Section 12 -2 -2
Building Height (maximum)
see definition Section 12 -2 -2
Sloping ft
Flat ft
Landscaping
See definition Section 14 -2 -1
Section 14 -10 -8
Softscape sq ft
Hardscape sq ft
TOTAL sq ft
Driveway
Sections 14 -3 -1 & 14 -3 -2
Max Curb -cuts
Max Grade @ cen-
terline
Min Width
Heated drive?
D Yes E]No
E]Yes EiNo
Snow Storage
Parking
Sections 12 -10 & 14 -5
#Enclosed Spaces
#Unenclosed
TOTAL
Outdoor Lighting (maximum)
Section 14 -10 -7
# fixtures
3
Bounkal Ham
AND SHRUBS
EXISTM TREES
• -./� a�
PROPOSED LANDSCAPING
Common Name Quanti Size
Minimum Requirements for Landscaping: Deciduous Trees — 2" Caliper
Coniferous Trees — 6' in height
Shrubs — 5 Gal.
Type Sgua m F00we
GROUND COVER
SOD
SEED
IRRIGATION
TYPE OF EROSION CONTROL
Please specify other landscape features (i.e. retaining walls, fences, swimming pools, etc.)
I
Buildina Materials
Roof
Siding
Other Wall Materials
Fascia
Soffits
Windows
Window Trim
Doors
Door Trim
Hand or Deck Rails
Flues
Flashing
Chimneys
Trash Enclosures
Greenhouses
Retaining Walls
Exterior Lighting
Other
PROPOSED MATERIALS
Type of Material
i(,G%Ure- '(' CAI eA 000v
Notes:
Please specify the manufacturer's name, the color name and numbe
36r► )C, ,",j iv---,-( 1- 6C6r_v-I ( NZ
Color
_ . M a
Vol,b
I�LD&. L,
�MOIA
1 •
SECTION 1 - GENERAL REQUIREMENTS
BUILDING JURISDICTION: TOWN OF VAIL, CO
JURISDICTION'S ADOPTED CODE: IBC /IRC 2009
BUILDING DESIGN LOADS:
DECK LIVE LOAD: 100 PSF
DECK DEAD LOAD: 15 PSF
WIND DESIGN: 90 MPH, EXP. B
SEISMIC DESIGN CATEGORY: C
1. DEFINITIONS:
A. ENGINEER: REFERENCES ON THE STRUCTURAL DRAWINGS TO'ENGINEER'
MEAN THE STRUCTURAL ENGINEER OF RECORD ( SER) . OTHER ENTITIES
ARE SPECIFICALLY NOTED AS "CONTRACTOR'S ENGINEER ", "MECHANICAL
ENGINEER ", ETC.
2. THESE NOTES SUPPLEMENT THE SPECIFICATIONS, WHICH SHALL BE REFERRED
TO FOR ADDITIONAL REQUIREMENTS.
3. UNDERGROUND UTILITIES: LOCATE EXISTING UTILITIES, AND NOTIFY ENGINEER
OF EXISTING UTILITIES OR SUB GRADE CONDITIONS WHICH INTERFERE WITH
WORK,
4. EXISTING STRUCTURES:
A. CONTRACT DOCUMENTS HAVE BEEN PREPARED USING AVAILABLE
DRAWINGS AND SITE OBSERVATION AS PERMITTED BY ACCESS
RESTRICTIONS DURING DESIGN.
B. DURING CONSTRUCTION, THE CONTRACTOR MAY ENCOUNTER EXISTING
CONDITIONS WHICH ARE NOT NOW KNOWN OR ARE AT VARIANCE WITH
PROJECT DOCUMENTATION ( DISCOVERY) .
C. CONTRACTOR SHALL NOTIFY THE ENGINEER OF ALL CONDITIONS NOT PER
THE CONTRACT DOCUMENTS. EXAMPLES INCLUDE:
• SIZES OR DIMENSIONS OTHER THAN THOSE SHOWN.
• DAMAGE OR DETERIORATION TO MATERIALS AND COMPONENTS.
• CONDITIONS OF INSTABILITY OR LACK OF SUPPORT.
• CONTRACTOR SHALL MAKE ALLOWANCE FOR THE RESOLUTION OF SUCH
DISCOVERIES IN THE CONSTRUCTION AND CONTINGENCY FEE SCHEDULES.
5. USE OF DRAWINGS:
A. DO NOT SCALE DRAWINGS.
B. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL NOTES
AND SPECIFICATIONS, THE MORE STRINGENT REQUIREMENTS SHALL
GOVERN, DETAILS ON DRAWINGS TAKE PRECEDENCE OVER GENERAL
NOTES AND TYPICAL DETAILS. DETAILS NOTED TYPICAL APPLY TO ALL
SIMILAR CONDITIONS, WHERE NO SPECIFIC DETAILS ARE SHOWN,
CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ELSEWHERE ON THE
PROJECT OR STANDARD CONSTRUCTION PRACTICES.
6. TEMPORARY CONDITIONS:
A. THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION.
THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL TEMPORARY
BRACING AND /OR SUPPORT THAT MAY BE REQUIRED AS THE RESULT OF THE
CONTRACTOR'S CONSTRUCTION METHODS AND /OR SEQUENCES.
CONTRACTOR'S CONSTRUCTION AND /OR ERECTION SEQUENCES SHALL
RECOGNIZE AND CONSIDER THE EFFECTS OF THERMAL MOVEMENTS OF
STRUCTURAL ELEMENTS DURING THE CONSTRUCTION PERIOD.
B. FOUNDATION WALLS SHALL NOT BE BACK FILLED UNTIL THE
SLABS -ON -GRADE AND UPPER SLABS ARE IN PLACE AND REACH FULL
STRENGTH UNLESS ADEQUATE BRACING IS PROVIDED. PROVIDE FREE
DRAINING BACK FILL ADJACENT TO FOUNDATION WALLS. USE ONLY HAND
OPERATED TOOLS FOR COMPACTION ADJACENT TO FOUNDATION WALLS.
7. SUBMITTALS AND SUBSTITUTIONS:
A. SUBMITTALS: REFER TO SPECIFICATIONS FOR DETAILED REQUIREMENTS. IF
THE CONTRACTOR REQUESTS A CHANGE FROM THE STRUCTURAL
DRAWINGS, IT SHALL BE APPROVED BY THE ARCHITECT AND DESIGNED BY
THE SER.
B. CONSTRUCTION DOCUMENTS SHALL NOT BE REPRODUCED FOR USE IN
SUBMITTALS.
C. SUBSTITUTIONS: ENGINEERS APPROVAL SHALL BE SECURED FOR ALL
SUBSTITUTIONS,
D. NONCONFORMANCE: NOTIFY ENGINEER OF CONDITIONS NOT
CONSTRUCTED PER THE CONTRACT DOCUMENTS PRIOR TO PROCEEDING
WITH CORRECTIVE WORK. SUBMIT PROPOSED REPAIR TO THE
ARCHITECT /OWNER/BUILDER FOR ACCEPTANCE.
8. OSHA STANDARDS:
A. THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION.
NOTHING SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE CONSTRUED
AS ELIMINATING THE NEED FOR THE CONTRACTOR TO COMPLY WITH ALL
OSHA REQUIREMENTS.
B. THE CONTRACTOR SHALL ADD ALL NECESSARY BOLTS, STIFFENERS, PLATES,
STABILIZERS, BRIDGING, BRACING, BEARING SEATS, COLUMN SPLICES, ETC.,
AS WALL AS CLOSURES FOR OPENINGS. IN ADDITION, FIELD WELD ANYTHING
THAT MY BE CONSIDERED A TRIP HAZARD, SUCH AS SHEAR STUDS, AFTER
PROTECTIVE DECKING IS INSTALLED.
C. WHERE THE STRUCTURAL DRAWINGS APPEAR TO CONFLICT WITH OSHA
REQUIREMENTS, THE STRUCTURAL DRAWINGS REPRESENT FINAL
CONDITION ONLY; THE CONTRACTOR SHALL ADD ALL ERECTION FRAMING AS
MAY BE NECESSARY TO COMPLY WITH OSHA.
9. COORDINATION:
A. STRUCTURAL DRAWINGS ARE NOT STAND -ALONE DOCUMENTS AND ARE
INTENDED TO BE USED IN CONJUNCTION WITH CIVIL, ARCHITECTURAL,
MECHANICAL, ELECTRICAL, AND DRAWINGS FROM OTHER DISCIPLINES. THE
CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE CONTRACT
DOCUMENTS INTO SHOP DRAWINGS AND WORK.
B. ARCHITECTURAL DRAWINGS, DRAWINGS FROM OTHER DISCIPLINES,
PROJECT SHOP DRAWINGS, AND FIELD CONDITIONS PRIOR TO SHOP
DRAWING SUBMITTAL.
SECTION 2 - WOOD
1. ENGINEERED LUMBER SIZES (MICROLAM, PARALAM, TIMBERSTRAND, AND
FABRICATED MEMBER SIZES) SHOWN ARE NET: OTHER MEMBER SIZES ARE
NOMINAL.
A. ALL COMPOSITE LAMINATED VENEER LUMBER (LVQ TO HAVE A
MINIMUM ALLOWABLE BENDING. STRESS OF 2800 PSI (2800Fb) AND
MODULUS OF ELASTICITY OF 1,900,000 PSI (1.9E) PER ICC /ICBO ES 4979.
B. ALL COMPOSITE PARALLEL STRAND LUMBER (PSL) TO HAVE A MINIMUM
ALLOWABLE BENDING STRESS OF 2850 PSI (2850Fb) AND MODULUS OF
ELASTICITY OF 2,000,000 PSI (2.0E) PER ICC /ICBO ES 4979.
C. MULTIPLE PLY MEMBERS TO BE NAILED TOGETHER USING 3 ROWS OF 16d
COMMON WIRE NAILS SPACED AT 16" O/C ( U.O.N.)
D. COMPOSITE LAMINATED STRAND LUMBER (LSL) IS MANUFACTURED BY
TRUS JOIST AND SHOULD BEAR THE LABEL OF "STRANDGARD" OR
"TI MBERSTAN D" WITH A MINIMUM MODULUS OF ELASTICITY OF 1,300,000
PSI (1.3E) PER ICC /ICBO ES 4979.
2. FRAMING LUMBER DRY (19% MAXIMUM MOISTURE CONTENT AT TIME OF
INSTALLATION) SHALL BE SHOWN BELOW WITH MINIMUM DESIGN VALUES
BASED ON THE 2005 NDS, UNLESS OTHERWISE NOTED.
A. EXTERIOR STUDS: DF NO.2 OR BETTER
B. LOAD BEARING STUDS (AND COLUMNS ASSEMBLED FROM STUDS) : DF
NO.2 OR BETTER
C. NON -LOAD BEARING INTERIOR STUDS: DF STUD OR BETTER
D. HEADERS AT TYPICAL OPENINGS: DF NO.2 OR BETTER
E. 2 "-4" NOMINAL MEMBERS: DF NO.2 OR BETTER
F. 5" NOMINAL AND LARGER MEMBERS: DF NO.1 OR BETTER
3. NAILING:
A. UNLESS NOTHED OTHERWISE ON THE DRAWINGS, PROVIDE BOX NAILS
WITH SIZES SHOWN ON THE DRAWINGS. MINIMUM NAILING SHALL BE IN
ACCORDANCE WITH THE NAILING SCHEDULE PER IBC2009 TABLE 2304.9.1
UNLESS NOTED OTHERWISE ON DRAWINGS.
ri
REPLACR DA 4ACTP.D
1 1/2" = P-0"
6X6 PUuSTPER PLAN
0
M •
DAMAGED 6X6 POST
TO BE REPLACED
ABA66 POST BASE - USE
LEVELING GROUT AS
REQUIRED,
5/8" DIA x 6" THREADED
ROD STET IN HILTI HY -150
EPDXY OR EQUIVALENT.
MIN 4" EMBED.
I U2" =1`-Q"
-CENSPACE, LLC
11332 OSWEGO STREET
i � i :i•� 1
PHONE: ( 303) 655 -9118
FAX: ( 303) 655 -9116
WWW.Censpace.com
TIMBER
CO 1280 N. Frontage Road
81657
COPYRIGHT
@ 2012 CENSPACE, LLC:
ALL RIGHTS RESERVED. THE INFORMATION DEPICTED ON THIS SHEET IS THE
SOLE PROPERTY OF CENSPACE, LLC AND NO PART OF THIS INFORMATION
MAY BE REPRODUCED IN ANY FORM WITHOUT THE WRITTEN PERMISSION OF
CENSPACE, LLC
PROFESSIONAL SEAL:
1, *mkk
I ` i 12" x 12" SQUARE ^ .
i ( i I { CONC CASSION I
L L L (Typ) L L
BUILDING "L" - EAST ELEVATION
NOTES: CONTRACTOR TO VERIFY ALL DIMENSIONS. SCALE: 1/4"= 1'-V
ROOF LEVEL
3RD FLOOR LEVEL
2ND FLOOR LEVEL
GROUND FLOOR
LEVEL
BUILDING "L" - 3RD FLOOR DECK. FRAMING (PARTIAL PLAN} BUILDING "K" - 3RD FLOOR DECK FRAMING (PARTIAL PLC
NOTES: CONTRACTOR TO VERIFY ALL DIMENSIONS. SCALE: 114"= V-0" NOTES: CONTRACTOR TO VERIFY ALL DIMENSIONS. SCALE: 1/4" = 1'-0"
BUILDING "L" - 2ND FLOOR DECK FRAMING (PARTIAL PLAN) BUILDING "K" - 2ND FLOOR DECK FRANnNG PARTIAL PLAN)
NOTES: CONTRACTOR TO VERIFY ALL DIMENSIONS. SCALE: 114"= i' -0" NOTES: CONTRACTOR TO VERIFY ALL DIMENSIONS. SCALE: 1(4" =1'-4"
1. PROVIDE 6X6 BEAMS UNDER DECK JOISTS WITH 6X6 POSTS AT 8' -0" O.C. (MAX.) FOR SHORING. BLOCK SOLID THROUGH
DECK FRAMING.
2. REMOVE AND REPLACE DAMAGED 2XI2 RIM BOARD AND /OR 2X10 LEDGER SECTIONS SHOWN HATCHED. NAIL EACH
MEMBER TOGETHER WITH FOUR ROWS OF 10d NAILS AT 16" O /C. STAGGER NAILS EVENLY BETWEEN EACH PLY.
3. REPLACE DAMAGED 2X10 JOISTS SHOWN HATCHED.
4. REPLACE FIRST THREE COURSES OF T &G DECKING AS INDICATED.
5. REPLACE DAMAGED 6X6 POSTS AS INDICATED.
6. REATTACH AND /OR REPLACE DAMAGED PORTIONS OF HANDRAIL.
7. ENSURE EACH END OF EACK JOIST IS ATTACHED TO SUPPORTING FRAMING WITH SIMPSON LU26 (SINGLE JOIST) OR
LU26 -2 (DOUBLE JOIST) PER MANUFACTURER'S SPECIFICATIONS.
8. REMOVE SHORING AFTER FRAMING IS IN PLACE AND FULLY SECURED.
NOTES:
(E) = EXISTING, (N} = NEW
ALL DAMAGED MEMBERS TO BE REPLACED WITH TREATED LUMBER. REFER TO SHEET SG.1 FOR ALL OTHER LUMBER SPECIFICATIONS.
C-
CENSPACE, LLC
STRUCTURAL ENGINEERING
11332 OSWEGO STREET
HENDERSON, CO 80644
PHONE: ( 303) 655 -9118
FAX: ( 303) 655 -9116
www.censpace.com
TIMBER RIDGE DECK REPAIR
80 Frontage lord
Vail, 81657
i!! E,
@ 2012 CENSPACE, LLC:
ALL RIGHTS RESERVED. THE INFORMATION DEPICTED ON THIS SHEET IS THE
SOLE PROPERTY OF CENSPACE, LLC AND NO PART OF THIS INFORMATION
MAY BE REPRODUCED IN ANY FORM WITHOUT THE WRITTEN PERMISSION OF
CENSPACE, LLC
i
DECK FRAMING
PLAN