HomeMy WebLinkAboutDRB120331 Project Name:TURLEY RES. DOOR REPLACEMENTS DRB Number: DRB120331 Project Description: REPLACE THREE SLIDING DOORS. ALL THREE FACE THE STREET AND WILL BE THE SAME SIZE WITH ALUMINUM CLADDING TO MATCH HOUSE COLORS. THE SLIDING DOORS ARE GOING FROM WHITE BACK TO TAN WHICH IS THE COLOR OF WINDOWS. Participants: OWNER TURLEY, MARSHALL F.-HAUSAM, 07/30/2012 4011 BIGHORN RD 6C VAIL CO 81657 CONTRACTOR ANKERHOLZ INC. 07/30/2012 Phone: 970-949-6341 PO BOX 296 AVON CO 81620 License: C000003141 APPLICANT TURLEY, MARSHALL F.-HAUSAM, 07/30/2012 4011 BIGHORN RD 6C VAIL CO 81657 Project Address:1151 SANDSTONE DR VAILLocation: UNIT A Legal Description:Lot: A-7 Block: 2 Subdivision: CASOLAR VAIL Parcel Number:2103-014-1400-4 Comments:See conditions BOARD/STAFF ACTION Motion By: Action: STAFFAPP Second By: Vote: Date of Approval: 08/06/2012 Conditions: Cond: 8 (PLAN): No changes to these plans may be made without the written consent of Town of Vail staff and/or the appropriate review committee(s). Cond: 0 (PLAN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to construction activities. Cond: 201 (PLAN): DRB approval shall not become valid for 20 days following the date of approval, pursuant to the Vail Town Code, Chapter 12-3-3: APPEALS. Cond: 202 (PLAN): Approval of this project shall lapse and become void one (1) year following the date of final approval, unless a building permit is issued and construction is commenced and is diligently pursued toward completion. Planner:Warren Campbell DRB Fee Paid: $20.00 TOWN Of VAJL Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970 -479 -2128 www.vailgov.com Development Review Coordinator Application for Design Review Minor Exterior Alteration General Information: This application is required for all proposals involving minor changes to buildings and site improve- ments, such as roofing, painting, window additions, landscaping, fences, retaining walls, etc. Applicable Vail Town Code sections can be found at www.vailgov.com under Vail Information – Town Code Online. All projects requiring de- sign review must receive approval prior to submitting a building permit application. An application for Design Review cannot be accepted until all required information is received by the Community Development Department, as outlined in the submittal requirements. The project may also need to be reviewed by the Town Council and /or the Planning and Environmental Commission. Design review approval expires one year from the date of approval, unless a building per- mit is issued and construction commences. _ AWOL _ Fee: for Multi - Family /Commercial 'o" or Single Family /Duplex FT Single Family i ✓ Duplex ' Multi- Family Description of the Request: Replace 3 Sliding doors. All 3 facing street. Doors will be same size with aluminum cladding to match house colors. Physical Address: 1151 Casolar Del Norte (A) Parcel Number: 2103 014 14 004 Property Owner. Turley, Marshall Mailing Address: 11 � t CAR e I Commercial (Contact Eagle Co. Assessor at 970 - 328 -8640 for parcel no.) LAA, a , uOrLTC AKA Phone VA4L Cp f t � S .7-- -7o — ' 1 (o - _7( 4 Owner's Signature: Primary Contact/ Owner Representative: Matt Sayre (Ankerholz Inc.) Mailing Address: PO BOX 296 AVON CO 81620 Phone: 970 -949 -6341 E -Mail: ankerholzinc @yahoo.com Fax: 970- 949 -6341 For Office Use Only: tir Cash_ CC: Visa/MC Last 4 CC # Exp. Date. Auth # Check # � Fee Paid: 6A '7;t,0. 0I) Meeting Date: Planner: Received From: t'NN1�E.'r-1d0 L 14J L . DRB No-: n 75 D 1 Project No: ti R Ts oZ — y` 13 Zoning: Land Use: Location of the Proposal: Lot: Block:_ Subdivision: r! ► L,&3 T_t JUL 27 ZUIn?_ IV.13fkin WIF TOWN OF VAIL (�7y� 0000frViA �Rll I, (print name JOINT PROPERTY OWNER WRITTEN APPROVAL LETTER C�- �fP il� . tic provide this letter as written approval of the plans dated 4t) a f property located at C-0 Wl� -1 which have been submitted to the Town of Vail Community Development Department for the proposed improvements to be completed at the address noted above. I understand that the proposed improvements include: (Signature) � (Date) Additionally, please check the statement below which is most applicable to you: 1 understand that minor modifications may be made to the plans over the course of the review rocess to ensure compliance with the Town's applicable codes and regulations. (Initial here) E7 1 request that all modifications, minor or otherwise, which are made to the plans over the course of the review process, be brought to my attention by the applicant for additional approval before undergoing further review by the Town. (Initial here) F. \cdev\ FORMS \Permits \Planning \DRB%joint property owner 10- 18- 2006.doc joint property owner letter revised 1011812006 Er 5 , k VOW 1�j 1 ' �� , , ... -. _.. • {rte t 4s r `a i '.1 Id ET PATIO DOOR GLAZING PERFORMANCE - TOTAL UNIT Prol-ine® Clad Contemporary Type of Glazing 1 /d" A.- It-, with 'A mm nlncc 0 tvJ f0 = J 4- Shaded Areas Meet ENERGY STAR' Performance Criteria in Zones Shown u U.S. Canadaz Zone JERI Zone 0.47 0 S 60 59 with grilles - between- the -glass 0.47 0.51 53 59 3/4" Advanced Low -E IG with argon with 3 mm glass with 9 ri I les-between-the-9 lass 0.30 0.30 0.28 0.24 52 45 60 60 18 16 " .- 3/4" NaturalSun Low -E IG with argon with 3 mm glass 0.32 0.52 58 58 29 with 9 ri I les-between-the-9 lass 0.32 0.46 50 58 26 ' 3/4" SunDefenseTm Low -E IG with argon with 3 mm glass 0.30 0.21 48 60 14 - with g ri I les-between-the-g lass 0.30 0.18 41 60 12 3/4" SunDefense Dual Low -E IG with argon with 3 mm glass 0.26 0.20 43 48 18 with grilles-between-the-glass 0.26 0.17 38 48 16 3/4" clear IG with 4 mm glass 0.49 0.56 60 60 with grilles-between-the-glass 0.50 0.49 52 60 3/4" Advanced Low -E IG with argon with 4 mm glass 0.32 0.27 51 59 15 with 9 ri I les- between-the-9 lass 0.32 0.24 44 59 13 3/4" NaturalSun Low -E IG with argon with 4 mm glass 0.32 0.50 58 57 28 with g ri Iles-between-the-g lass 0.32 0.44 50 57 25 3/4" SunDefense Low -E IG with argon with 4 mm glass 0.32 0.21 47 59 11 with g rilles- between- the -glass 0.33 0.18 41 59 3/4" SunDefense Dual Low -E IG with argon with 4 mm glass 0.28 0.20 43 47 16 with i rilles- between -the lass 0.29 0.18 37 47 13 3/4" Advanced Low -E IG air - filled High Altitude with 3 mm glass 0.35 0.28 52 55 with g rilles- between -the- lass 0.35 0.25 45 55 3/4" NaturalSun Low -E IG air - filled High Altitude with 3 mm glass 0.35 0.52 58 55 26 with grilles- between- the -glass 0.35 0.45 50 55 21 3/4" SunDefense Low -E IG air - filled High Altitude with 3 mm glass 0.35 0.21 48 57 with grilles-between-the-glass 0.35 0.19 41 57 3/4" SunDefense Dual Low -E IG air - filled HA with 3 mm glass 0.30 0.20 43 44 13 with g ri I les-between-the-g lass 0.30 0.18 38 44 12 3/4" Advanced Low -E IG air - filled High Altitude with 4 mm glass 0.35 0.28 51 59 with grilles-between-the-glass 0.35 0 -24 44 59 3/4" NaturalSun Low -E IG air - filled High Altitude with 4 mm glass 0.36 0.50 58 53 23 with grilles-between-the-9 lass 0.36 0.44 50 53 3/4" SunDefense Low -E IG air - filled High Altitude with 4 mm glass 0.35 0.21 47 55 with grilles-between-the-glass 0.37 0.19 41 55 3/4" SunDefense Dual Low -E IG air - filled HA with 4 mm glass 0.31 0.20 43 43 12 with grilles - between- the -glass 0.32 0.18 37 43 10 Climate R -Value - 1/U- Factor See the Product Performance section for more SHGC - Solar Heat Gain Coefficient detailed information or visit www.energystacgov - VLT % - Visible Light Transmission for Energy Star guidelines. CR - Condensation Resistance N ER - Canadian Energy Rating NC (1) Glazing performance values are calculated based on NFRC 100. SC (2) The values shown are based on Canada's updated ENERGY STAR* initiative. For center -glass values, see the Product Performance section. Ak ^ Pella 2012 Architectural Design Manual I Division 08 - Openings I Windows and Doors I www.PellaADM.com W -SD -1 1 o� O Eo , 7. U C v°u A, v o f0 c c g v.4 c0C ON ENO goo Lri „e I�I N o L