Loading...
HomeMy WebLinkAboutF12-0039 CUT SHEETS �(�cQ Fire & Building Products rapid response� HOME FIRE SPRINKLER SYSTEM Technical Services: Tel: (800)381-9312/Fax: (800)791-5500 Series LFII Residential Horizontal Sidewall Sprinklers 4 .4 K-factor vides 1/4 inch (6,4 mm) of recessed G e n e ra 1 adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush De s c ri p t i o n mounting surface position.The adjust- The T co� Ra id Res onseT"", Series ment provided by the Recessed Es- Y p� p cutcheon reduces the accuracy to LFII (TY2334) Residential Horizontal which the pipe nipples to the sprinklers Sidewall Sprinklers are decorative, must be cut. � fast response, frangible bulb sprin- �"^�`�, klers designed for use in residential The Series LFII (TY2334) has been .�,, � occupancies such as homes, apart- designed with heat sensitivity and ����� ments, dormitories, and hotels. When Water distribution characteristics r' aesthetics and optimized flow charac- proven to help in the control of residen- �'- --►..�,„ teristics are the major consideration, tial fires and to improve the chance for the Series LFII (TY2334)should be the occupants to escape or be evacuated. first choice. The Series LFII are to be used in wet WARNINGS pipe residential sprinkler systems for The Series LFII (TY2334) Residential one-and two-family dwellings and mo- Horizontal Sidewall Sprinklers de- bile homes per NFPA 13D; wet pipe scribed herein must be installed and residential sprinkler systems for resi- maintained in compliance with this dential occupancies up to and includ- document, as well as with the applica- ing four stories in height per NFPA ble standards of the National Fire Pro- 13R;or, wet pipe sprinkler systems for tection Association, in addition to the the residential portions of any occu- standards ofany otherauthorities hav- /� pancy per NFPA 13. ing jurisdiction. Failure to do so may '�� � The Series LFII (TY2334) has a 4.4 �mpair the performance of these de- (63,4) K-factor that provides the re- vices. �� �, quired residential flow rates at reduced The owner is responsible for maintain- pressures,enabling smaller pipe sizes ing their fire protection system and de- and water supply requirements. vices in proper operating condition. The recessed version of the Series The installing contractor or sprinkler LFII (TY2334) is intended for use in manufacturer should be contacted areas with finished walls. It employs a with any questions. two-piece Style 20 Recessed Escutch- eon. The Recessed Escutcheon pro- Sprinkler/Model IMPORTANT Identification Always refer to Technical Data N u m b e r Sheet TFP700 for the "INSTALLER WARN/NG" that provides cautions SIN TY2334 with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 DECEMBER, 2007 TFP412 Components: WRENCH 1 - Frame — FLATS �/�/RENCH 2 - Button � I I FLATS 3 - Sealing TOP-OF- � ���I� �� � Assembly DEFLECTOR �1/2"NPT \ 4 - Bulb 5 - Compression 7/16"(11,1 mm) Screw 1 � � NOMINAL 2-7/8"DIA. 6 - Deflector* + � 6* 5 4 2 MAKE-IN (73,0 mm) � � \ , *Temperature rating � � _ CENTERLINE is indicated on top i� �� � OF WATERWAY of Deflector. ��16�� 1 — ' STYLE 20 g RECESSED (11,1 mm) � ��z„ i ESCUTCHEON END-OF- ~(38,1 mm)~\� ESCUTCHEON DEFLECTOR 2-1/8" PLATE SEATING BOSS ! (54,0 mm) SURFACE RECESSED F/GURE 1 SER/ES LFII(TY2334)RES/DENTIAL HORIZONTAL S/DEWALL AND RECESSED HORIZONTAL S/DEWALL SPRINKLERS 7/16±1/8" � � �(11,1±3,2 mm) � � � MOUNTING FACE OF WRENCH RECESS � (END"A"USED SURFACE � SPRWKLER FORTY2334) FITTING TOP-OF- CLOSURE _ F/GURE 3 DEFLECTOR � � W-TYPE 6 SPRINKLER WRENCH � TY2334 � I 2-7/8"DIA. (73,0 mm) WRENCH RECESS � 2-1/4"DIA. � (57,2 mm) � 7/16" � � (11,1 mm) � / MOUNTING � PLATE �� END-OF- �� DEFLECTOR ��$" PUSH WRENCH BOSS (3,2 mm) IN TO ENSURE ENGAGEMENT 1-1/4"(31,8 mm) 1/2"(12,7 mm) WITH SPRINKLER 1"(25,4 mm) 1/4"(6,4 mm) WRENCHING AREA FIGURE 4 FIGURE 2 W-TYPE 7 RECESSED STYLE 20 RECESSED ESCUTCHEON SPRINKLER WRENCH FOR USE W/TH THE SER/ES LFII(TY2334) RES/DENTIAL HOR/ZONTAL S/DEWALL SPR/NKLER 3 total number of"design sprinklers" as sufficientadjustmentinanEscutcheon h n specified in NFPA 13D or NFPA 13R. Plate by under- or over-tightening the For systems designed to NFPA 13,the Sprinkler. Readjust the position of the number of design sprinklers is to be sprinkler fitting to suit. Approvals: the four most hydraulically demanding The Series LFII Horizontal Sidewall UL and C-UL Listed. sprinklers. The minimum required dis- Sprinklers must be installed in ac- charge from each of the four sprinklers cordance with the following instruc- Maximum Working Pressure: is to be the greater of the following: tions. 175 psi (12,1 bar) • The flow rates given in Tables A, B, Step 1. Horizontal sidewall sprinklers Discharge Coefficient: C, and D for NFPA 13D and 13R as are to be installed in the horizontal K=4.4 GPM/psi��2 (63,4 LPM/bar�i2) a function of temperature rating and position with their centerline of water- Temperature Rating: the maximum allowable coverage way perpendicular to the back wall and 155°F/68°C or 175°F/79°C area. parallel to the ceiling. The word "TOP" Finishes: • A minimum discharge of 0.1 gpm/sq. on the Deflector is to face towards the ceiling with the front edge of the De- White Polyester Coated, ft. over the "design area"comprised flector parallel to the ceiling. Chrome Plated, or Natural Brass of the four most hydraulically de- manding sprinklers for the actual Step 2. With pipe thread sealant ap- Physical Characteristics: coverage areas being protected by plied to the pipe threads, hand tighten Frame . . . . . . . . . . . . . . Brass the four sprinklers. the sprinkler into the sprinkler fitting. Button . . . . . . . . . . . . . Bronze Obstruction To Water Distribution. Step 3. Tighten the sprinkler into the Sealing Assembly . . . . . . . . . • Locations of sprinklers are to be in sprinkler fitting using only the W-Type . Beryllium Nickel w/Teflont accordance with the obstruction rules 6 Sprinkler Wrench (Ref. Figure 3). Bulb . . . . . . . . . 3 mm dia. Glass of NFPA 13 for residential sprinklers. With reference to Figure 1,the W-Type Compression Screw . . . . . Bronze 6 Sprinkler Wrench is to be applied to Deflector . . . . . . . . . . . Copper Operational Sensitivity. The sprin- the wrench flats. klers are to be installed with an end-of- tDupont Registered Trademark deflector-boss to wall distance of 1- The Series LFII Recessed Horizontal 3/8 to 6 inches or in the recessed po- Sidewall Sprinklers must be installed sition using only the Style 20 Re- in accordance with the following in- � n cessed Escutcheon as shown in structions. The glass Bulb contains a fluid that Figure 2. Step A. Recessed horizontal sidewall expands when exposed to heat.When In addition the top-of-deflector-to-ceil- sprinklers are to be installed in the the rated temperature is reached, the ing distance is to be within the range horizontal position with their centerline fluid expands sufficiently to shatter the (Ref. Table A, B, C, or D) being hy- of waterway perpendicular to the back glass Bulb allowing the sprinkler to draulically calculated. wall and parallel to the ceiling. The activate and flow water. Sprinkler Spacing. The minimum Word "TOP" on the Deflector is to face spacing between sprinklers is 8 feet towards the ceiling. n (2,4 m). The maximum spacing be- Step B. After installing the Style 20 tween sprinklers cannot exceed the Mounting Plate over the sprinkler width of the coverage area(Ref.Table threads and with pipe thread sealant A)being hydraulically calculated(e.g., applied to the pipe threads, hand The Tyco° Rapid ResponseT"", Series maximum 12 feet for a 12 ft. x 12 ft. tighten the sprinkler into the sprinkler LFII (TY2334) Residential Horizontal coverage area, or 16 feet for a 16 ft. x fitting. Sidewall Sprinklers are UL and C-UL 20 ft. coverage area). Step C. Tighten the sprinkler into the Listed for installation in accordance sprinkler fitting using only the W-Type with the following criteria. n n 7 Recessed Sprinkler Wrench (Ref. Figure 4). With reference to Figure 1, NOTE The Series LFII (TY2334) must be in- the W-Type 7 Recessed Sprinkler When conditions exist that are outside stalled in accordance with the follow- Wrench is to be applied to the sprinkler the scope of the provided criteria,refer ing instructions: wrench flats. to the Residential Sprinkler Design NOTES Step C. After the wall has been in- Guide TFP490 for the manufacturer's Do not install any bulb type sprinkler if stalled or the finish coat has been ap- recommendations that may be accept- the bulb is cracked or there is a loss of plied, slide on the Style 20 Closure able to the local Authority Having Ju- liquid from the bulb. With the sprinkler over the Series LFII Sprinkler and risdiction. held horizontally, a small air bubble push the Closure over the Mounting System Type. Only wet pipe systems should be present. The diameterof the Plate until its flange comes in contact may be utilized. air bubble is approximately 1/16 inch with the wall. (1,6 mm). Hydraulic Design. The minimum re- quired sprinkler flow rate for systems A 1/2 inch NPT sprinkler joint should designed to NFPA 13D or NFPA 13R be obtained with a minimum to maxi- are given in Table A, B, C, and D as a mum torque of 7 to 14 ft.lbs. (9,5 to function of temperature rating and the 19,0 Nm). Higher levels of torque may maximum allowable coverage areas. distort the sprinkler inlet with conse- The sprinkler flow rate is the minimum quent leakage or impairment of the required discharge from each of the sprinkler. Do not attempt to compensate for in- (Continued on Page 8) ........................................................................................................ ........................................................................................................ ........................................................................................................ : � ELEVATION Maximum Maximum Coverage Spacing Minimum Flow(�1 and Residual Pressure Area�a� Ft. Width x Length�b1 (m) Top-Of-Deflector-To-Ceiling: Top-Of-Deflector-To-Ceiling: Ft.x Ft. 4 to 6 Inches(100 to 150 mm) 6 to 12 Inches(150 to 300 mm) (m x m) 155°F/68°C 175°F/79°C 155°F/68°C 175°F/79°C 12 x 12 12 13 GPM(49,2 LPM) 13 GPM(49,2 LPM) 13 GPM(49,2 LPM) 13 GPM(49,2 LPM) (3,7 x 3,7) (3,7) 8.7 psi(0,60 bar) 8.7 psi(0,60 bar) 8.7 psi(0,60 bar) 8.7 psi(0,60 bar) 14 x 14 14 14 GPM(53,0 LPM) 14 GPM(53,0 LPM) 14 GPM(53,0 LPM) 14 GPM(53,0 LPM) (4,3 x 4,3) (4,3) 10.1 psi(0,70 bar) 10.1 psi(0,70 bar) 10.1 psi(0,70 bar) 10.1 psi(0,70 bar) 16 x 16 16 16 GPM(60,6 LPM) 16 GPM(60,6 LPM) 17 GPM(64,3 LPM) 17 GPM(64,3 LPM) (4,9 x 4,9) (4,9) 13.2 psi(0,91 bar) 13.2 psi(0,91 bar) 14.9 psi(1,03 bar) 14.9 psi(1,03 bar) 16 x 18 16 19 GPM(71,9 LPM) 19 GPM(71,9 LPM) 20 GPM(75,7 LPM) 20 GPM(75,7 LPM) (4,9 x 5,5) (4,9) 18.6 psi(1,28 bar) 18.6 psi(1,28 bar) 20.7 psi(1,43 bar) 20.7 psi(1,43 bar) 16 x 20 16 23 GPM(87,1 LPM) 23 GPM(87,1 LPM) 23 GPM(87,1 LPM) 23 GPM(87,1 LPM) (4,9 x 6,1) (4,9) 27.3 psi(1,88 bar) 27.3 psi(1,88 bar) 27.3 psi(1,88 bar) 27.3 psi(1,88 bar) 18 x 18 18 23 GPM(87,1 LPM) 23 GPM(87,1 LPM) 23 GPM(87,1 LPM) 23 GPM(87,1 LPM) (5,5 x 5,5) (5,5) 27.3 psi(1,88 bar) 27.3 psi(1,88 bar) 27.3 psi(1,88 bar) 27.3 psi(1,88 bar) 18 x 20 18 26 GPM(98,4 LPM) 26 GPM(98,4 LPM) 26 GPM(98,4 LPM) 26 GPM(98,4 LPM) (5,5 x 6,1) (5,5) 34.9 psi(2,41 bar) 34.9 psi(2,41 bar) 34.9 psi(2,41 bar) 34.9 psi(2,41 bar) (a) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Width (backwall where sprinkler is located)x Length(horizontal throw of sprinkler). (c) Requirement is based on minimum flow in GPM (LPM)from each sprinkler.The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design Criteria Section for details. (d)Sidewall sprinklers,where installed under a ceiling with a slope greater than 0 inch rise for a 12 inch run to a slope up to 2 inch rise for 12 inch run, must be located per one of the following: • Locate the sprinklers at the high point of the slope and positioned to discharge down the slope. • Locate the sprinklers along the slope and positioned to discharge across the slope. TABLE A NFPA 13D AND NFPA 13R WET PIPE HYDRAUL/C DESIGN CRITER/A FOR THE SER/ES LFII(TY2334) RES/DENTIAL HOR/ZONTAL S/DEWALL AND RECESSED HOR/ZONTAL S/DEWALL SPR/NKLERS FOR HORIZONTAL CEIL/NG(Maximum 21nch Rise for 12 Inch Run) 5 12" :; ���`����:�. 8" MAX I M U M ELEVATION Minimum Flow��>and Residual Pressure (I)Two sprinkler design with the sprinklers at the high point of the slope and positioned to discharge down the slope. Maximum Maximum Coverage Spacing Area�a> Ft. Width x Length�b> (m) Ft.x Ft. Top-Of-Deflector-To-Ceiling: Top-Of-Deflector-To-Ceiling: (m x m) 4 to 6 Inches(100 to 150 mm) 6 to 12 Inches(150 to 300 mm) 155°F/68°C 175°F/79°C 155°F/68°C 175°F/79°C 12 x 12 12 I 23 GPM(87,1 LPM) I 23 GPM(87,1 LPM) ( 23 GPM(87,1 LPM) l 23 GPM(87,1 LPM) (3,7 x 3,7) (3,7) 27,3 psi(1,88 bar) 27,3 psi(1,88 bar) 27,3 psi(1,88 bar) 27,3 psi(1,88 bar) 14 x 14 14 I 23 GPM(87,1 LPM) I 23 GPM(87,1 LPM) I 23 GPM(87,1 LPM) [ 23 GPM(87,1 LPM) (4,3 x 4,3) (4,3) 27,3 psi(1,88 bar) 27,3 psi(1,88 bar) 27,3 psi(1,88 bar) 27,3 psi(1,88 bar) 16 x 16 16 I 23 GPM(87,1 LPM) 1 23 GPM(87,1 LPM) I 23 GPM(87,1 LPM) [ 23 GPM(87,1 LPM) (4,9 x 4,9) (4,9) 27,3 psi(1,88 bar) 27,3 psi(1,88 bar) 27,3 psi(1,88 bar) 27,3 psi(1,88 bar) 16 x 18 16 1 23 GPM(87,1 LPM) I 23 GPM(87,1 LPM) I 23 GPM(87,1 LPM) l 23 GPM(87,1 LPM) (4,9 x 5,5) (4,9) 27,3 psi(1,88 bar) 27,3 psi(1,88 bar) 27,3 psi(1,88 bar) 27,3 psi(1,88 bar) 16 x 20 16 I 23 GPM(87,1 LPM) I 23 GPM(87,1 LPM) ( 23 GPM(87,1 LPM) l 23 GPM(87,1 LPM) (4,9 x 6,1) (4,9) 27,3 psi(1,88 bar) 27,3 psi(1,88 bar) 27,3 psi(1,88 bar) 27,3 psi(1,88 bar) 18 x 18 18 I 23 GPM(87,1 LPM) 1 23 GPM(87,1 LPM) [ 23 GPM(87,1 LPM) I 23 GPM(87,1 LPM) (5,5 x 5,5) (5,5) 27,3 psi(1,88 bar) 27,3 psi(1,88 bar) 27,3 psi(1,88 bar) 27,3 psi(1,88 bar) 18 x 20 18 I 26 GPM(98,4 LPM) 1 26 GPM(98,4 LPM) I 26 GPM(98,4 LPM) [ 26 GPM(98,4 LPM) (5,5 x 6,1) (5,5) 34.9 psi(2,41 bar) 34.9 psi(2,41 bar) 34.9 psi(2,41 bar) 34.9 psi(2,41 bar) (a) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b)Width (backwall where sprinkler is located)x Length(horizontal throw of sprinkler). (c) Requirement is based on minimum flow in GPM (LPM)from each sprinkler.The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design Criteria Section for details.. TABLE B NFPA 13D AND NFPA 13R WET P/PE HYDRAUL/C DES/GN CRITERIA FOR THE SER/ES LFII(TY2334) RES/DENT/AL HOR/ZONTAL S/DEWALL AND RECESSED HORIZONTAL SIDEWALL SPR/NKLERS FOR SPR/NKLERS AT THE H/GH PO/NT OF THE SLOPE AND D/SCHARG/NG DOWN THE SLOPE (Greater Than 2 Inch Rise for 12 Inch Run Up To 8/nch Rise for 12 Inch Run) O w y o The Tyco� Rapid ResponseT"", Series Products manufactured by Tyco Fire& When placing an order, indicate the LFII (TY2334)must be maintained and Building Products (TFBP) are war- full product name. Contact your local serviced in accordance with the follow- ranted solely to the original Buyer for distributor for availability.. ing instructions: ten (10)years against defects in mate- Sprinkler Assembly: NOTES rial and workmanship when paid for Absence of an Escutcheon Plate may and properly installed and maintained Series LFII (TY2334), K=4.4, Residen- delay the sprinkler operation in a fire under normal use and service. This tial Horizontal Sidewall Sprinkler with situation. warranty will expire ten (10) years (specify) temperature rating and from date of shipment by TFBP. No (specify)finish, P/N (specify). Before closing a fire protection system Warranty is given for products or com- main control valve for maintenance ponents manufactured by companies �ss°F/68°c or work on fhe fire protection system not affiliated by ownership with TFBP Chrome Plated ......... P/N 51-215-9-155 which it controls, permission to shut or for roducts and com onents which 155°Fisa°c down the affected fire protection sys- p p White Polyester......... P/N 51-215-4-155 tem must be obtained from the proper have been subjectto misuse,improper �ss°F/68°c authorities and all ersonnel who ma �nstallation, corrosion, or which have Natural Brass........... P/N 51-215-1-155 p y not been installed, maintained, modi- ��5°F/79°c or be affected by this action must be no- fied or repaired in accordance with ap- cnrome Piated ......... PiN s�-z�5-s-��5 tified, licable Standards of the National Fire 175°F/79°c p White Polyester......... P/N 51-215-4-175 Sprinklers which are found to be leak- Protection Association, and/or the 175°F/79°c ing or exhibiting visible signs of corro- standards of any other Authorities Natural Brass........... P/N 51-215-1-175 sion must be replaced. Having Jurisdiction. Materials found Recessed Escutcheon: Automatic sprinklers must never be by TFBP to be defective shall be either painted, plated, coated, or otherwise repaired or replaced, at TFBP's sole Specify: Style 20 Recessed Escutch- altered after leaving the factory. Modi- option. TFBP neither assumes, nor eon with (specify�) finish, P/N (spec- fied sprinklers must be replaced. authorizes any person to assume for it, ify'). Sprinklers that have been exposed to any other obligation in connection with corrosive products of combustion, but the sale of products or parts of prod- •Refer to Technical Data Sheet TFP770. have not operated,should be replaced ucts.TFBP shall not be responsible for if they cannot be completely cleaned sprinkler system design errors or inac- Sprinkler Wrench: by wiping the sprinkler with a cloth or curate or incomplete information sup- Specify: W-Type 6 Sprinkler Wrench, by brushing it with a soft bristle brush. plied by Buyer or Buyer's repre- P/N 56-000-6-387. Care must be exercised to avoid dam- sentatives. Specify: W-Type 7 Sprinkler Wrench, age to the sprinklers - before, during, In no event shall TFBP be liable, in P/N 56-850-4-001. and after installation. Sprinklers dam- contract, tort, strict liability or under aged by dropping, striking, wrench any other legal theory, for incidental, twist/slippage, or the like, must be re- indirect,special or consequential dam- placed.Also,replace any sprinkler that ages, including but not limited to labor has a cracked bulb or that has lost charges, regardless of whether TFBP liquid from its bulb. (Ref. Installation vvas informed about the possibility of Section). such damages, and in no event shall The owner is responsible for the in- TFBP's liability exceed an amount spection, testing, and maintenance of equal to the sales price. their fire protection system and de- The foregoing warranty is made in lieu vices in compliance with this docu- of any and all other warranties. ex- ment, as well as with the applicable press or implied. including warranties standards of the National Fire Protec- Qf inerchantability and fitness for a par_ tion Association (e.g., NFPA 25), in ticular purpose. addition to the standards of any other authorities having jurisdiction. The in- This limited warranty sets forth the ex- stalling contractor or sprinkler manu- clusive remedy for claims based on facturer should be contacted relative failure of or defect in products, materi- to any questions. als or components, whether the claim NOTE is made in contract, tort, strict liability The owner must assure that the sprin- or any other legal theory. klers are not used for hanging of any This warranty will apply to the full ex- objects and that the sprinklers are only tent permitted by law.The invalidity, in cleaned by means of gently dusting �nihole or part, of any portion of this with a feather duster, otherwise, non- Warranty will not affect the remainder. operation in the event of a fire or inad- vertent operation may result. Automatic sprinkler systems should be inspected,tested,and maintained by a qualified Inspection Service in accord- ance with local requirements and/or national codes. O 2007 TYCO FIRE 8�BUILDING PRODUCTS,451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Engineering Data . Working Pressures Rated Internal Working Pressures of Piping System and Solder Made of Copper Water Tube and Soldered Fittings The table of maximum working Seruice POUNDS PER SQUARE INCH pressures below must be Solder Used Temp. Water(a) understood to reflect what is �n jainis °F Capper Water Tube-Nominal Sizes enerall considered as ood %"to 1" 1'/<"to 2" 2�"to 4" 5"to 8' 'The data given for 50%tin-50%lead applies g y g also for the 40%tin-60%lead alloy. engineering practice under Incl. Incl. Incl. Incl. '50-50 100 200 175 150 135 The values in this table are based on data in reasonably constant and the National Bureau of Standards Publications, favorable conditions; I.@., Tin-Lead(b) 150 150 125 100 90 "Building Materials and Structures Reports pressures which are fairly 200 100 90 75 70 BMS 58 and BMS 83." steady, absence of particularly 2b0 $b 75 5� 45 (a) Including other noncorrosive liquids and 95-5 100 500 400 300 27p gases corrosive media, etc. Unusual (b) ASTM B32,Alloy Grade Sn 50 conditions require increased Tin-Antimony 150 400 350 275 250 (�) ASTM B32,Alloy Grade Sb 5 safety factors and therefore, (C)�d) 2�0 3�� 25� 2�� 18� (d) of 1 86 p ohibits9he utse ncpo able wa[er. lower working pressures 250 200 175 150 135 Systems of any solder having a lead should be used. Brazing Alloys Temperature and pressure ratings consistent with the content in excess of 2%. Melting at or materials and procedures emplayed. NoTE:rne tabie ac ien�5 f�om aara P�brSned ahave 1000°F. by the Copper and Brass Research Association. Estimated Quantity of 50-50 Solder Required to Make 100 Joints Size in Inches 3/8 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 3 1/2 4 5 6 8 Quantity in Pounds .5 .75 1.0 1.4 1.7 1.9 2.4 3.2 3.9 4.5 5.5 8 15 32 1.The quantity of hard solder used is dependent in the skill of the operator,but for estimating purposes,75%of the above figures may be used. 2.Two ounces of Solder Flux will be required for each pound of solder. Wrot Copper and Bronze Solder-Joint Pressure Fittings Male End Dimensions of Soldered-Joint Ends (in inches) Ti �--K-'� Male End Female End Inside 1 � Stantlard Diameter o A Water Ouside Inside Wall of 1 + Tube Diameter Length Diameter Depth Thickness Fitting T� Size A K F G T 0 Min. Max. Min. Min, Max. Min. Avg. Min. � } 1/8 0.248 0.251 0.31 0.252 0.256 0.25 .019 0.18 o I 1/4 0.373 0.376 0.38 0.377 0.381 0.31 .023 0.30 I I 3/8 0.497 0.501 0.44 0.502 0.506 0.38 .026 0.39 ± � 1/2 0.622 0.626 0.56 0.627 0.631 0.50 .029 0.52 T} 5/8 0.747 0.751 0.69 0.752 0.756 0.62 .031 0.63 Female End 3/4 0.872 0.876 0.81 0.877 0.881 0.75 .033 0.74 I_--c-I iT 1 1.122 1.127 0.97 1.128 1.132 0.91 .040 0.98 } � } " 1 1/4 1.372 1.377 1.03 1.378 1.382 0.97 .044 1.23 1 1/2 1.621 1.627 1.16 1.628 1.633 1.09 .051 1.47 I I 2 2.121 2.127 1.41 2.128 2.133 1.34 .059 1.94 1 � 21/2 2.621 2.627 1.53 2.628 2.633 1.47 .067 2.42 tT 3 3.121 3.127 1.72 3.128 3.133 1.66 .075 2.89 -c- 3 1/2 3.621 3.627 1.97 3.628 3.633 1.91 .086 3.37 } � 4 4.121 4.127 2.22 4.128 4.133 2.16 .096 3.84 I F O 5 5.121 5.127 2.72 5.128 5.133 2.66 .111 4.70 � I 6 6.121 6.127 3.22 6.128 6.133 3.09 .124 5.72 � 8 8.119 8.127 4.09 8.128 8.133 3.97 .173 7.55 tr T Elkhart Products Corporation 39 . Engineering Data Wrot Copper Solder-Joint Drainage Fittings Dimensions of Soldered-Joint Ends (in inches) See Diagram Page 39 Male End Female End Inside Metal Diameter Size Outside Diameter Length Insitle Diameter Depth Thickness of Fitting A K F G T 0 Min. Max. Min. Min. Max. Min. Min. Min. 1 1/4 1.372 1.377 0.56 1.378 1.382 0.50 0.040 1.29 1 1/2 1.621 1.627 0.62 1.628 1.633 0.56 0.042 1.53 2 2.121 2.�27 0.69 2.�28 2.133 0.62 �.�42 2.0� Extracted from American National Standard Wrought Copper 3 3.121 3.127 0.81 3.128 3.133 0.75 1.045 2.g$ and Bronze Solder-Joint Drainage Fiitings(ANSI B16.29)with permission of the publisher. The American Society of 4 4.121 4.127 1.06 4.128 4.133 1.00 0.058 3.93 Mechanical Engineers,345 East 47th St.,New York,N.Y. Wrot Copper Fittings Large Diameter Welded Design Fitting Material: Methotl of Joining: Copper Alloy#122, Phosphorus Electric Weld. Deoxidized-HighoResidual Phosphoruo (DHP). Dimensions & Specifications: Composition: 99/o Copper; .015-.040/o Phosphorus. EPC Welded fittings are produced in accordance with Weld Material: specifications shown in Manufactures Standardization Silicon Bronze. Meets specification Society(MSS) SP-109 for wrought copper, and copper American Welding Society (AWS)A5.7-91 R alloy solder-joint pressure fittings. and American Metals Society. Testing: Weld Specifications: Each fitting is individually tested with air under water. Tensile Strength-Up to 58,000 PSI The burst pressure of EPC welded fittings exceeds Yield Strength-Up to 25,000 PSI the recommended working pressure of comparable Elongation in 2"-53% to 55% diameter, annealed, straight, seamless ASTM B88- Hardness-80 to 100 Brinell (500kg. Load) 96-A type "L" copper water tube by a safety factor Temperature: Melt 1832°F, Flow 1931°F. of 4:1 or more. Copper Water Tube-Standard Dimensions and Weights Outside Inside Diameter, Inches Wall Thickness, Inches tPounds per Linear Foot Nominal Dia., In. Tube Types Type Type Type Type Type Type Type Type Type Type Type Type Size K-L-M- K L M DWV K L M DWV K L M DWV Inches DWV 1/4 .375 .305 .315 - - .035 .030 .025 - .145 .126 .106 - 3/8 .500 .402 .430 - - .049 .035 .025 - .269 .198 .145 - 1/2 .625 .527 .545 - - .049 .040 .028 - .344 285 .204 - 5/8 .750 .652 .666 - - .049 .042 .030 - .418 .362 .263 - 3/4 .875 .745 .785 - - .065 .045 .032 - .641 .455 .328 - 1 1.125 .995 1.025 - - .065 .050 .035 - .839 .655 .465 - 1 1/4 1.375 1245 1.265 1.291 1.295 .065 .055 .042 .040 1.04 .884 .682 .650 1 1/2 1.625 1.481 1.505 1.527 1.541 .072 .060 .049 .042 1.36 1.14 .940 .809 2 2.125 1.959 1.985 2.009 2.041 .083 .070 .058 .042 2.06 1.75 1.46 1.07 2 1/2 2.625 2.435 2.465 2.495 - .095 .080 .065 - 2.93 2.48 2.03 - 3 3.125 2.907 2.945 2.981 3.035 .109 .090 .072 .045 4.00 3.33 2.68 1.69 3 1/2 3.625 3.385 3.425 3.459 - .120 .100 .083 - 5.12 4.29 3.58 - 4 4.125 3.857 3.905 3.935 4.009 .134 .110 .095 .058 6.51 5.38 4.66 2.87 5 5.125 4.805 4.875 4.907 4.981 .160 .125 .109 .072 9.67 7.61 6.66 4.43 6 6.125 5.741 5.845 5.881 5.959 .192 .140 .122 .083 13.9 10.2 8.92 6.10 8 8.125 7.583 7.725 7.785 - 271 .200 .170 - 25.9 19.3 16.5 - 4� Elkhart Products Corporation tSlight variations from these weights must be expected in practice. FIGURE 5. Selected Pressure Fittings ADAPTERS OO � i0 �O FTGxM FTGxF CxC Adapter Adapter Union �0 03 OO OO � '� �O C x M C x F C x C x F Adapter Adapter Tee ELBOWS � � OO z0 10 10 CxC :, x C CxCxC 45° Elbow 9�° -1bow Tee z0 OO OO z0 �O �O FTGx C FTGxC CxFTGxC a5° Elbow 90°Elbow Tee COUPLINGS OO i0 CxC CxC CxC CxC Roll Stop Staked Stop No Stop Reducing GENERAL NOTES: (a) Fittings are designated by size in the order: 1x2x3(b) Fitting designs and drawings are for illustration only. 36 ST E E L — sammys � Self-Dr�illing • Self-tapping � � � � . , . Use#14 Nut Driver(Item#100) �� Item# Model Screw gox Qty W��g�t Case Qty �• Descri 6on (p' ) `� 50 DSTR 100 1/4-20x1 100 6.z5 1000 � 51 DST100 1/4-14x1 lo0 525 l000 � i t 52 DST150 1/4-14x11/2 lo0 5.50 l000 t 53 DST 200 1/4-14� 100 6.00 1000 54 DST250 1/4-14x21/2 lo0 6.75 l000 #14 55 DST300 ]/4-]4x3 100 725 1000 Qtem#1o0.black) Sammys 1/4",3/8"rod 56 TEK500 12-24x1 1/2 �o0 5.50 �000 - : ' � � i Use#14 Nut Driver Qtem#100) Approvals Item# Moc�l Screw FMTest ULTest iJ[JFM 1VI'inimam Malrimam AcYual Pullout Bo� Descri fion Load,lb. Loadlb. Pi Size Thickness Thickness u�•FM•NFPA 29 DSTR11/2" 12-24x1 1/2 1475# 1500# 3/4-4 I/4" 1/2" 1510#/1/4" 1 u�•FM•NFPA 30 DSTR1" 1/4-20x1 1475# 1500# 3/4-4 036"-20ga 1/4" 1570#/20ga 1 u�•NFPA 31 DSTRSl6 5/16-18x11/4 1500# 4 036"-20ga 1/4" 2200#/20ga 1 �FPA 32 DST10 1/4-14x1 Note:Screwdiameter/design/ 036"-20 ga 1/4" 446#/20 ga I NFP/+ 33 DSTlS 1/4-14x11/2 per/i�rm�mce�ordeeDSTlO(!" 1/4" 970#/L6ga ] NFP/+ 34 DST20 1/4-14� length)through the DST 30(3" 1/4" 1 NFPA 35 DST25 V4-14a21/2 �engrlr)nreconstantOn[yNie V4" 1 NFP/+ 36 DST30 U4-14� ler�gthsvary. 1/4" I u�•NFPA 37 DST516 5/16-18x1 1/4 ISOOl1 4 188"-3/16" 1/4" 1500N�/3/16" ] FM•NFPA 38 �j'g�gp ]2-24X� �/2 1475# I/4" U2" 3125#/1/4" 1 ' 1 � 1 Use#14SW NutDriver(Item#101) Item# Modcl Screw NGnimum Maximum Actual Pullout Box Qty �'cight Casc Qty Descri tion Thickness Thickness (per 100) - 601 DST2.0 1/4-14� �88"-3n6" 1/a" 50 6.75 500 1113 DST2.5 l/4-14a21/2 188"-3/16" 1/4" 50 7.25 500 � 422 DSTR 1.0 1/4-20x1 036°-20 ga 1/4" 1510#/20 ga 50 500.00 7 -- 28 DSTR 5.16 5/16-18x1 1/4 036"-20 ga 1/4" 2220#/20 ga 50 8.00 500 #14SW (Item#101-red) 443 DST516 5/16-18x11/4 188"-3/16" 1/4" 1500+#/3/16" 50 6J5 500 Sidewinders& OS TEK5.0 12-24X11/2 25"-L/4" 1/2" 3125#�/L/4" 50 6.00 500 Sammys7/Y'rod � 1 -- � �r � : �..�" For fastenin�/anchoring in high vibratory environments, consult local code au�lzorities for accepted anchoring devices Page 6 ' � � � Note:Screws n¢ust be instulled witk appropriute nxt driver to comp[v with wnrranty STEEL —sidewinders �A Self-D�illing • Self-tapping • #14SW Qtem#101-red) Sidewinders& " Sammys 1/2"rod ��� ' 1 1 1 1 1 I _� � Use#14SW Nut Driver(Item#101) �;��'�' Item# Model Screw Minimum Maximum Actual BoX Q� Wcight Case Qty � �, Descri 'on Thickness Thickness Shear/Pulloat (per 100) --� -- 2003 SWD 100 1/4-14x1 066"-16 ga t/4" 1477#/16 ga 100 6.00 1000 407 SWD 200 1/4-14x2 O66"-16�a 1/4" 1477#/16 ga 100 6.50 1000 szeeLsarcvshmrnn�iUrreminerriut 206 SWDR1�� 1/4-�.0 036"-20ga 1/4" 1900t{/20ga 100 6.00 1000 SWDR srrews include retainer nui i � 1 1 1 1 1 Use#14SW Nut Driver(Item#101) Screw UL Test UL/FM Minimum Maximum Actual Weigh Approval Item# Model Descri ion Loadlb. Pi Size Thickness Thickness Shcar/Pullout BoxQTy ��er1oC 39 SWD 10 1/4-14x1 O66"-16 ga I/4" 1477N/16 ga l00 6A0 40 SWD15 1/4-14x11/2 No/e:Screwdimxeter/desi�n/per�ormanceJorSWD10(1"length) l00 7.50 4l SWD 20 1/4-14x2 through SWD 20(2"length)nre eoNSUenL Only the dengths varry. l00 6.50 42 SWD516 5/16-18x11/4 ioo �.00 46 SWDR11/2" 1/4-20x11/2 1500# 4 25"-t/4" 1�2^ z375#�.z5"-1/4" t0o 7.25 43 SWDR1" 1/4-20x1 1500# 4 036"-20ga 1/4" 1900#/20ga 100 7.00 44 SWDR516 5/16-18x11/4 1500# 4 036"-20ga 7/4" 2480#/20ga 100 8.25 45 SWT15 12-24x11/2 25"-L/4" 1/2" 100 625 � � . � , � � � . SHEET STEEL GAUGES Gauge No. 1/4 3/16 12 14 16 18 20 22 24 26 Decimal Equivalent .25 .188 .105" .075" .060" .048" .036" .030" .024" .018" '� Ultimate Pullout Values -Sammys (average Ibs.ultimate) Fastener Steel Gauge Model Dia. Pt. 20 18 16 14 12 3/16 1/4 DST 1/4 #3 446# 613# 970# 1145# 1544# 3190# DST 516 5/16 #3 457# 568# 1209# 1712# 2422# 3716# TE}(50 #12 #5 487# 699# 913# 1527# 3270# 3593# DSTR 1 1/2" #12 #5 3270# 3593# DSTR1" 1/4 #3 1510# DSTR516 5/16 #3 2200# Aluminum Curtain Wall Extrusion Ultimate Shear I Pullout Values-Sidewinders Ultimate Pullout Values (average Ibs.ultimate) (average Ibs.ultimate) Fastener SteelGauge Fastener Thickness Model Dia. Pt. 20 18 16 14 12 3/16 1/4 Model Dia. Pt. .114 .092 .365 .132 SWD 1/4 #3 1477# DST 10 1/4 #3 1265# 2750# SWDR 1 1/2" #12 #5 2375# SWD 10 1/4 #3 1120# 1420# SWDR 1" 1/4 #3 1900# 1900# SWDR 516 5/16 #3 2480# 2480# For fastening/anchoring i�r high vibratory environments, consult local code authorities for accepted anchorin�clevices Note:Screive'nrust be iirsta/let!witlr nppropriate r:ut driver to emnply ivi77�warru>ery Page 7 ��0� 302 RING HANGER SIZE- 1/2 thru 8 inch pipe. MATERIAL-Sta1riICSS StCCI-�TypC 304� IMPERIAL MAX REC. METRIC* CONFORMS WITH: Federal Specification WW-H-171 (Type 10, PIPE Ro� LOAD LBS. pIPE Roo Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10). �i� 3is aoo �o MAXIMUM TEMPERATURE-6500F. 3i4 3�$ aoo Za ,� FUNCTION-Pipe hanger component far use on steel ar 1 g�g aoo 2s io copper piping.For use with CPVC-consult factory. � va 3�8 aoo 3z io INSTALLATION-Per NFPA-13, 13R and 13D. � vz 3�$ aoo 40 �o FEATURES- z 3�$ 400 50 �� * Sized and listed exclusively for use with#310 Surge Restrainer. * Stainless steel swivel nut. ��iz 3�$ soo 65 �o * Custom fit swivel nut for better retention in ring body. 3 3�$ 600 so io ORDERING-Part#,pipe size. 3��� 3ie 600 io 4 3B i000 �oo io Note: On Copper-Insulate pipe. 5 ��z �2so 125 �z 6 ��2 1250 150 12 $ 1/2 1250 200 12 'Order Part#300m Note:1/2"Ring Hanger not<FM>approved 08/03 f�'� ���, � 650 ALL THREADED ROD 10' - 0' LENGTHS ROD MAX.REC.LOAD LBS. SIZE FOR SERVICE TEMP. 650°F 750°F 1/4 240 215 3/g 610 540 �/2 1130 1010 5/g 1810 1610 3/4 2710 2420 7/g 3770 3360 � 4960 4420 1 1/4 8000 7140 1 1/2 11630 10370 NOTE;maximum Temperature:750°F SIZE- 1/4 thru 1 1/2 inch rod in 10'-0"lengths. MATERIAL-Carbon Steel. FINISH-Plain,Electro-Galvanized and Stainless Steel. ORDERING-Part#,rod diameter and finish. 2/00