Loading...
HomeMy WebLinkAboutB12-0331 ASBESTOS REPORTSEMSL Analytical, Inc. 1010 Yuma Street, Denver, CO 80204 Phone/Fax:(303) 740-5700 / (303) 741-1400 http://www.emsl.com denverlab@emsl.com 221202660 CustomerID:INES78 CustomerPO: ProjectID: EMSL Order: Attn:Quentin Danziger Indoor Environmental Services, Inc. P.O. Box 997 Vail, CO 81658 Received:07/18/12 8:30 AM Gorsuch Offices Vail Fax: Phone:(970) 390-0087 Project: 7/18/2012Analysis Date: 7/17/2012Collected: Sample Description Appearance % Type AsbestosNon-Asbestos % Fibrous % Non-Fibrous Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy 05-02-Tape 221202660-0018A Front Office Room- Sheetrock/Joint Compound Tan None Detected Fibrous Heterogeneous Cellulose100%Non-fibrous (other)0% 05-02-Joint Compound 221202660-0018B Front Office Room- Sheetrock/Joint Compound White None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 05-02-Drywall 221202660-0018C Front Office Room- Sheetrock/Joint Compound Brown/White None Detected Fibrous Heterogeneous Cellulose10%Non-fibrous (other)90% 05-03-Texture 221202660-0019 Front Office Room- Sheetrock/Joint Compound White None Detected Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Non-fibrous (other)100% 05-03-Tape 221202660-0019A Front Office Room- Sheetrock/Joint Compound Tan None Detected Fibrous Homogeneous Cellulose100%Non-fibrous (other)0% 05-03-Joint Compound 221202660-0019B Front Office Room- Sheetrock/Joint Compound White None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 05-03-Drywall 221202660-0019C Front Office Room- Sheetrock/Joint Compound Brown None Detected Fibrous Heterogeneous Cellulose10%Non-fibrous (other)90% 7Test Report PLM-7.16.0 Printed: 7/19/2012 9:27:59 AM Erin Orthun, Laboratory Manager or other approved signatory Analyst(s) EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0 Report Amended: 07/19/2012 09:27:59 Replaces the Inital Report 07/18/2012 16:15:12. Reason Code: Client-Change to Appearance Erin Orthun (50) Michael DeCavallas (29) RECEIV VED 07/27/12 EMSL Analytical, Inc. 1010 Yuma Street, Denver, CO 80204 Phone/Fax:(303) 740-5700 / (303) 741-1400 http://www.emsl.com denverlab@emsl.com 221202660 CustomerID:INES78 CustomerPO: ProjectID: EMSL Order: Attn:Quentin Danziger Indoor Environmental Services, Inc. P.O. Box 997 Vail, CO 81658 Received:07/18/12 8:30 AM Gorsuch Offices Vail Fax: Phone:(970) 390-0087 Project: 7/18/2012Analysis Date: 7/17/2012Collected: Sample Description Appearance % Type AsbestosNon-Asbestos % Fibrous % Non-Fibrous Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy 06-01 221202660-0020 Front Office Storage Closet Vinyl Flooring Beige Fibrous Heterogeneous Chrysotile20%Cellulose10%Non-fibrous (other)70% 06-02 221202660-0021 Front Office Storage Closet Vinyl Flooring Beige Fibrous Heterogeneous Chrysotile20%Cellulose10%Non-fibrous (other)70% 06-03 221202660-0022 Front Office Storage Closet Vinyl Flooring Beige Fibrous Heterogeneous Chrysotile20%Cellulose10%Non-fibrous (other)70% 07-01-Top Mastic 221202660-0023 Front Office-Floor Mastic/Leveler Yellow None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 07-01-Fibrous Layer 221202660-0023A Front Office-Floor Mastic/Leveler Gray Fibrous Heterogeneous Chrysotile35%Cellulose60%Non-fibrous (other)5% 07-01-Bottom Mastic 221202660-0023B Front Office-Floor Mastic/Leveler Tan None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 07-02-Fibrous Layer 221202660-0024 Front Office-Floor Mastic/Leveler Gray Fibrous Heterogeneous Chrysotile35%Cellulose60%Non-fibrous (other)5% 07-02-Mastic 221202660-0024A Front Office-Floor Mastic/Leveler Tan None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 8Test Report PLM-7.16.0 Printed: 7/19/2012 9:27:59 AM Erin Orthun, Laboratory Manager or other approved signatory Analyst(s) EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0 Report Amended: 07/19/2012 09:27:59 Replaces the Inital Report 07/18/2012 16:15:12. Reason Code: Client-Change to Appearance Erin Orthun (50) Michael DeCavallas (29) EMSL Analytical, Inc. 1010 Yuma Street, Denver, CO 80204 Phone/Fax:(303) 740-5700 / (303) 741-1400 http://www.emsl.com denverlab@emsl.com 221202660 CustomerID:INES78 CustomerPO: ProjectID: EMSL Order: Attn:Quentin Danziger Indoor Environmental Services, Inc. P.O. Box 997 Vail, CO 81658 Received:07/18/12 8:30 AM Gorsuch Offices Vail Fax: Phone:(970) 390-0087 Project: 7/18/2012Analysis Date: 7/17/2012Collected: Sample Description Appearance % Type AsbestosNon-Asbestos % Fibrous % Non-Fibrous Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy 07-03-Mastic 221202660-0025 Front Office-Floor Mastic/Leveler Tan None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 07-03-Fibrous Layer 221202660-0025A Front Office-Floor Mastic/Leveler Gray Fibrous Homogeneous Chrysotile35%Cellulose60%Non-fibrous (other)5% 08-01-Linoleum 221202660-0026 Level 2 Office Vinyl Flooring Beige None Detected Fibrous Heterogeneous Cellulose20% Glass10% Non-fibrous (other)70% 08-01-Mastic 221202660-0026A Level 2 Office Vinyl Flooring Tan None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 08-02-Linoleum 221202660-0027 Level 2 Office Vinyl Flooring Beige None Detected Fibrous Heterogeneous Cellulose20% Glass10% Non-fibrous (other)70% 08-02-Mastic 221202660-0027A Level 2 Office Vinyl Flooring Tan None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 08-03-Linoleum 221202660-0028 Level 2 Office Vinyl Flooring Beige None Detected Fibrous Heterogeneous Cellulose20% Glass10% Non-fibrous (other)70% 08-03-Mastic 221202660-0028A Level 2 Office Vinyl Flooring Tan None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 9Test Report PLM-7.16.0 Printed: 7/19/2012 9:27:59 AM Erin Orthun, Laboratory Manager or other approved signatory Analyst(s) EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0 Report Amended: 07/19/2012 09:27:59 Replaces the Inital Report 07/18/2012 16:15:12. Reason Code: Client-Change to Appearance Erin Orthun (50) Michael DeCavallas (29) EMSL Analytical, Inc. 1010 Yuma Street, Denver, CO 80204 Phone/Fax:(303) 740-5700 / (303) 741-1400 http://www.emsl.com denverlab@emsl.com 221202660 CustomerID:INES78 CustomerPO: ProjectID: EMSL Order: Attn:Quentin Danziger Indoor Environmental Services, Inc. P.O. Box 997 Vail, CO 81658 Received:07/18/12 8:30 AM Gorsuch Offices Vail Fax: Phone:(970) 390-0087 Project: 7/18/2012Analysis Date: 7/17/2012Collected: Sample Description Appearance % Type AsbestosNon-Asbestos % Fibrous % Non-Fibrous Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy 09-01-Linoleum 221202660-0029 Level 3 Office Vinyl Flooring Gray None Detected Fibrous Heterogeneous Cellulose20% Glass10% Non-fibrous (other)70% 09-01-Mastic 221202660-0029A Level 3 Office Vinyl Flooring Tan None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 09-02-Linoleum 221202660-0030 Level 3 Office Vinyl Flooring Gray None Detected Fibrous Heterogeneous Cellulose20% Glass10% Non-fibrous (other)70% 09-02-Mastic 221202660-0030A Level 3 Office Vinyl Flooring Tan None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 09-03-Linoleum 221202660-0031 Level 3 Office Vinyl Flooring Gray None Detected Fibrous Heterogeneous Cellulose20% Glass10% Non-fibrous (other)70% 09-03-Mastic 221202660-0031A Level 3 Office Vinyl Flooring Tan None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 10-01 221202660-0032 Shop-Speckled Green Vinyl Flooring Tan/Green None Detected Fibrous Heterogeneous Cellulose20%Non-fibrous (other)80% 10-02-Linoleum 221202660-0033 Shop-Speckled Green Vinyl Flooring Tan/Green None Detected Fibrous Heterogeneous Cellulose15%Non-fibrous (other)85% 10Test Report PLM-7.16.0 Printed: 7/19/2012 9:27:59 AM Erin Orthun, Laboratory Manager or other approved signatory Analyst(s) EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0 Report Amended: 07/19/2012 09:27:59 Replaces the Inital Report 07/18/2012 16:15:12. Reason Code: Client-Change to Appearance Erin Orthun (50) Michael DeCavallas (29) Indoor Environmental Services, Inc Project: Gorsuch Offices Vail, Colorado Asbestos Sampling Report – Page 1 of 2 July 19, 2012 Kevin Squires - George Shaeffer Construction On July 17, 2012, Quentin Danziger conducted an asbestos inspection of the suspect materials in the offices. Asbestos WAS FOUND, as described below. Homogenous Area Description Number of Samples % Asbestos Square Feet Type/Friable? 01 Main Big Flat Texture 5 Non-Detect 02 Sheetrock / Joint Compound with Main Big Flat Texture 5 <1% Composite 1000 - 5000 Misc/No 03 Copy Room Texture 3 Non-Detect 04 Faint Texture – Front Office Room 3 Non-Detect 05 Front Office Room Sheetrock Joint Compound 3 06 Front Office Storage Closet – Vinyl Flooring 3 20%~100 Misc/No 07 Front Office Floor Mastic / Fibrous Layer Under Carpet 3 35%<1000 Misc/No 08 Office 2nd Level Vinyl Flooring 3 Non-Detect 09 Office 3rd Level Vinyl Flooring 3 Non-Detect 10 Shop – Green Speckled Vinyl Flooring 3 Non-Detect 11 Shop – Dark Green Vinyl Floor 3 Non-Detect Indoor Environmental Services, Inc Project: Gorsuch Offices Vail, Colorado Asbestos Sampling Report – Page 2 of 2 BACKGROUND: A remodel is planned for the offices. Indoor Environmental Services, dba Built Forensics, was requested to conduct an asbestos inspection of the suspect materials that will be effected in the remodel. This inspection includes only suspect materials that are accessible to the inspector. If other suspect materials become visible during demolition, they must be sampled before they are disturbed. Examples of suspect materials include but are not limited to: linoleum, floor tile, ceiling tile, mastic, sheetrock, joint compound, roofing materials, etc. There are over 3000 known asbestos containing materials. CONCLUSIONS: Asbestos WAS FOUND in the linoleum flooring in the big front office storage closet (20%), and in the “fibrous layer” under the carpet in the big front office (35%). If these materials are to be disturbed, it should be done only by a professional asbestos abatement company and personnel, currently qualified and certified by the State of Colorado. Asbestos WAS FOUND in the joint compound (<1%), under the big flat texture that is found on most of the office walls and ceilings that make up the Tower. Less than 1% asbestos in Joint Compound – Important Details Since the joint compound contains less than 1% asbestos, it is under the State of Colorado's radar for Permitting. HOWEVER, the EPA (disposal) does care, and OSHA (worker safety) does care. Therefore, all Federal Regulations from EPA and OSHA having to do with the handling and disposal of Asbestos Containing Material, DO APPLY. These Regulations amount to a complete asbestos abatement project. Indoor Environmental Services strongly recommends that, if the walls and/or ceilings with big flat texture is to be disturbed, it be done by a qualified, professional asbestos abatement company. Note that the State of Colorado does NOT require this, in this particular circumstance. The industry refers to this material as “OSHA Sheetrock”. This will help when describing the situation to abatement contractors. They will also need the square footage Indoor Environmental Services, Inc Project: Gorsuch Offices Vail, Colorado Asbestos Sampling Report – Page 3 of 2 of the area to be removed/disturbed. The square footages referenced above are not meant for bidding purposes. Asbestos Abatement Contractors The following contractors have earned a reputation for being responsive and doing a professional job. Indoor Environmental Services gets nothing from recommending them, except peace-of-mind that we recommend good companies to our clients. Rocky Mountain Abatement - Richard Capra - 303-619-8023 - Cell Stink, Inc – Bob Hamilton – 303-886-4719 – Cell Prestige Environmental – Paul Radford - 303-371-8118 SAMPLING PLAN - REGULATIONS: Colorado State Requirements - For each homogenous area of less than 1000 square feet, a minimum of three samples must be collected in random areas. For each homogenous area of 1000 – 5000 square feet, a minimum of five samples must be collected in random areas. Areas of 5001 square feet or greater require a minimum of 7 samples. These laws are defined by the EPA (AHERA) and Colorado State Regulation 8. Determination of homogenous sampling areas – Homogenous Areas are determined by type of suspect material, texture, color and location. Determination of random sampling areas – The samples were collected in a random manner within each homogenous area. Thank you for using Indoor Environmental Services, Inc. We are proud to be your local indoor air quality consultants. We look forward to working with you in the future. Quentin Danziger, BS, ABI, CIEC – Colorado Asbestos Inspector Certification # 12781 Indoor Environmental Services, Inc. 970-541-4747 BuiltForensics.com ColoradoAsbestos.com EMSL Analytical, Inc. 1010 Yuma Street, Denver, CO 80204 Phone/Fax:(303) 740-5700 / (303) 741-1400 http://www.emsl.com denverlab@emsl.com 221202660 CustomerID:INES78 CustomerPO: ProjectID: EMSL Order: Attn:Quentin Danziger Indoor Environmental Services, Inc. P.O. Box 997 Vail, CO 81658 Received:07/18/12 8:30 AM Gorsuch Offices Vail Fax: Phone:(970) 390-0087 Project: 7/18/2012Analysis Date: 7/17/2012Collected: Sample Description Appearance % Type AsbestosNon-Asbestos % Fibrous % Non-Fibrous Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy 01-01 221202660-0001 Main Big Flat Texture White None Detected Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Non-fibrous (other)100% 01-02 221202660-0002 Main Big Flat Texture White None Detected Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Non-fibrous (other)100% 01-03 221202660-0003 Main Big Flat Texture White None Detected Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Non-fibrous (other)100% 01-04 221202660-0004 Main Big Flat Texture White None Detected Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Non-fibrous (other)100% 01-05 221202660-0005 Main Big Flat Texture White None Detected Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Non-fibrous (other)100% 02-01-Joint Compound A 221202660-0006 Sheetrock/Joint Compound w/Main Big Flat Texture Gray/White None Detected Inseparable paint / coating layer included in analysis No drywall present Non-Fibrous Heterogeneous Non-fibrous (other)100% 1Test Report PLM-7.16.0 Printed: 7/19/2012 9:27:59 AM Erin Orthun, Laboratory Manager or other approved signatory Analyst(s) EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0 Report Amended: 07/19/2012 09:27:59 Replaces the Inital Report 07/18/2012 16:15:12. Reason Code: Client-Change to Appearance Erin Orthun (50) Michael DeCavallas (29) EMSL Analytical, Inc. 1010 Yuma Street, Denver, CO 80204 Phone/Fax:(303) 740-5700 / (303) 741-1400 http://www.emsl.com denverlab@emsl.com 221202660 CustomerID:INES78 CustomerPO: ProjectID: EMSL Order: Attn:Quentin Danziger Indoor Environmental Services, Inc. P.O. Box 997 Vail, CO 81658 Received:07/18/12 8:30 AM Gorsuch Offices Vail Fax: Phone:(970) 390-0087 Project: 7/18/2012Analysis Date: 7/17/2012Collected: Sample Description Appearance % Type AsbestosNon-Asbestos % Fibrous % Non-Fibrous Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy 02-01-Tape 1 221202660-0006A Sheetrock/Joint Compound w/Main Big Flat Texture Tan None Detected Fibrous Homogeneous Cellulose100%Non-fibrous (other)0% 02-01-Joint Compound B 221202660-0006B Sheetrock/Joint Compound w/Main Big Flat Texture White None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 02-01-Tape 2 221202660-0006C Sheetrock/Joint Compound w/Main Big Flat Texture Tan None Detected Fibrous Heterogeneous Cellulose100%Non-fibrous (other)0% 02-01-Joint Compound C 221202660-0006D Sheetrock/Joint Compound w/Main Big Flat Texture White None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 02-02-Joint Compound 221202660-0007 Sheetrock/Joint Compound w/Main Big Flat Texture Gray/White None Detected Inseparable paint / coating layer included in analysis No drywall present Non-Fibrous Heterogeneous Non-fibrous (other)100% 02-02-Tape 1 221202660-0007A Sheetrock/Joint Compound w/Main Big Flat Texture Tan None Detected Fibrous Homogeneous Cellulose100%Non-fibrous (other)0% 02-02-Joint Compound A 221202660-0007B Sheetrock/Joint Compound w/Main Big Flat Texture White None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 2Test Report PLM-7.16.0 Printed: 7/19/2012 9:27:59 AM Erin Orthun, Laboratory Manager or other approved signatory Analyst(s) EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0 Report Amended: 07/19/2012 09:27:59 Replaces the Inital Report 07/18/2012 16:15:12. Reason Code: Client-Change to Appearance Erin Orthun (50) Michael DeCavallas (29) EMSL Analytical, Inc. 1010 Yuma Street, Denver, CO 80204 Phone/Fax:(303) 740-5700 / (303) 741-1400 http://www.emsl.com denverlab@emsl.com 221202660 CustomerID:INES78 CustomerPO: ProjectID: EMSL Order: Attn:Quentin Danziger Indoor Environmental Services, Inc. P.O. Box 997 Vail, CO 81658 Received:07/18/12 8:30 AM Gorsuch Offices Vail Fax: Phone:(970) 390-0087 Project: 7/18/2012Analysis Date: 7/17/2012Collected: Sample Description Appearance % Type AsbestosNon-Asbestos % Fibrous % Non-Fibrous Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy 02-02-Tape 2 221202660-0007C Sheetrock/Joint Compound w/Main Big Flat Texture Tan None Detected Fibrous Homogeneous Cellulose100%Non-fibrous (other)0% 02-02-Joint Compound B 221202660-0007D Sheetrock/Joint Compound w/Main Big Flat Texture White None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 02-03-Joint Compound A 221202660-0008 Sheetrock/Joint Compound w/Main Big Flat Texture White Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Chrysotile<1%Non-fibrous (other)100% 02-03-Tape 221202660-0008A Sheetrock/Joint Compound w/Main Big Flat Texture Tan None Detected Fibrous Homogeneous Cellulose100%Non-fibrous (other)0% 02-03-Joint Compound B 221202660-0008B Sheetrock/Joint Compound w/Main Big Flat Texture White Non-Fibrous Homogeneous Chrysotile<1%Non-fibrous (other)100% 02-03-Drywall 221202660-0008C Sheetrock/Joint Compound w/Main Big Flat Texture Brown/White None Detected Fibrous Heterogeneous Cellulose10%Non-fibrous (other)90% 02-03-Composite 221202660-0008D Sheetrock/Joint Compound w/Main Big Flat Texture Brown/Tan/White Fibrous Heterogeneous Chrysotile<1%Cellulose10%Non-fibrous (other)90% 3Test Report PLM-7.16.0 Printed: 7/19/2012 9:27:59 AM Erin Orthun, Laboratory Manager or other approved signatory Analyst(s) EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0 Report Amended: 07/19/2012 09:27:59 Replaces the Inital Report 07/18/2012 16:15:12. Reason Code: Client-Change to Appearance Erin Orthun (50) Michael DeCavallas (29) EMSL Analytical, Inc. 1010 Yuma Street, Denver, CO 80204 Phone/Fax:(303) 740-5700 / (303) 741-1400 http://www.emsl.com denverlab@emsl.com 221202660 CustomerID:INES78 CustomerPO: ProjectID: EMSL Order: Attn:Quentin Danziger Indoor Environmental Services, Inc. P.O. Box 997 Vail, CO 81658 Received:07/18/12 8:30 AM Gorsuch Offices Vail Fax: Phone:(970) 390-0087 Project: 7/18/2012Analysis Date: 7/17/2012Collected: Sample Description Appearance % Type AsbestosNon-Asbestos % Fibrous % Non-Fibrous Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy 02-04-Joint Compound A 221202660-0009 Sheetrock/Joint Compound w/Main Big Flat Texture White Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Chrysotile<1%Non-fibrous (other)100% 02-04-Tape 221202660-0009A Sheetrock/Joint Compound w/Main Big Flat Texture Tan None Detected Fibrous Homogeneous Cellulose100%Non-fibrous (other)0% 02-04-Joint Compound B 221202660-0009B Sheetrock/Joint Compound w/Main Big Flat Texture White Non-Fibrous Homogeneous Chrysotile<1%Non-fibrous (other)100% 02-04-Drywall 221202660-0009C Sheetrock/Joint Compound w/Main Big Flat Texture Brown None Detected Fibrous Heterogeneous Cellulose10%Non-fibrous (other)90% 02-04-Composite 221202660-0009D Sheetrock/Joint Compound w/Main Big Flat Texture Brown/White Fibrous Heterogeneous Chrysotile<1%Cellulose10%Non-fibrous (other)90% 02-05-Joint Compound A 221202660-0010 Sheetrock/Joint Compound w/Main Big Flat Texture White Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Chrysotile<1%Non-fibrous (other)100% 02-05-Tape 221202660-0010A Sheetrock/Joint Compound w/Main Big Flat Texture Tan None Detected Fibrous Homogeneous Cellulose100%Non-fibrous (other)0% 4Test Report PLM-7.16.0 Printed: 7/19/2012 9:27:59 AM Erin Orthun, Laboratory Manager or other approved signatory Analyst(s) EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0 Report Amended: 07/19/2012 09:27:59 Replaces the Inital Report 07/18/2012 16:15:12. Reason Code: Client-Change to Appearance Erin Orthun (50) Michael DeCavallas (29) EMSL Analytical, Inc. 1010 Yuma Street, Denver, CO 80204 Phone/Fax:(303) 740-5700 / (303) 741-1400 http://www.emsl.com denverlab@emsl.com 221202660 CustomerID:INES78 CustomerPO: ProjectID: EMSL Order: Attn:Quentin Danziger Indoor Environmental Services, Inc. P.O. Box 997 Vail, CO 81658 Received:07/18/12 8:30 AM Gorsuch Offices Vail Fax: Phone:(970) 390-0087 Project: 7/18/2012Analysis Date: 7/17/2012Collected: Sample Description Appearance % Type AsbestosNon-Asbestos % Fibrous % Non-Fibrous Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy 02-05-Joint Compound B 221202660-0010B Sheetrock/Joint Compound w/Main Big Flat Texture White Non-Fibrous Homogeneous Chrysotile<1%Non-fibrous (other)100% 02-05-Drywall 221202660-0010C Sheetrock/Joint Compound w/Main Big Flat Texture Brown/White None Detected Fibrous Heterogeneous Cellulose10%Non-fibrous (other)90% 02-05-Composite 221202660-0010D Sheetrock/Joint Compound w/Main Big Flat Texture Brown/White Fibrous Heterogeneous Chrysotile<1%Cellulose10%Non-fibrous (other)90% 03-01 221202660-0011 Copy Room Texture White None Detected Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Non-fibrous (other)100% 03-02 221202660-0012 Copy Room Texture White None Detected Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Non-fibrous (other)100% 03-03 221202660-0013 Copy Room Texture White None Detected Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Non-fibrous (other)100% 04-01 221202660-0014 Faint Texture- Front Office Room White None Detected Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Non-fibrous (other)100% 5Test Report PLM-7.16.0 Printed: 7/19/2012 9:27:59 AM Erin Orthun, Laboratory Manager or other approved signatory Analyst(s) EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0 Report Amended: 07/19/2012 09:27:59 Replaces the Inital Report 07/18/2012 16:15:12. Reason Code: Client-Change to Appearance Erin Orthun (50) Michael DeCavallas (29) EMSL Analytical, Inc. 1010 Yuma Street, Denver, CO 80204 Phone/Fax:(303) 740-5700 / (303) 741-1400 http://www.emsl.com denverlab@emsl.com 221202660 CustomerID:INES78 CustomerPO: ProjectID: EMSL Order: Attn:Quentin Danziger Indoor Environmental Services, Inc. P.O. Box 997 Vail, CO 81658 Received:07/18/12 8:30 AM Gorsuch Offices Vail Fax: Phone:(970) 390-0087 Project: 7/18/2012Analysis Date: 7/17/2012Collected: Sample Description Appearance % Type AsbestosNon-Asbestos % Fibrous % Non-Fibrous Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy 04-02 221202660-0015 Faint Texture- Front Office Room White None Detected Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Non-fibrous (other)100% 04-03 221202660-0016 Faint Texture- Front Office Room White None Detected Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Non-fibrous (other)100% 05-01-Texture 221202660-0017 Front Office Room- Sheetrock/Joint Compound White None Detected Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Non-fibrous (other)100% 05-01-Tape 221202660-0017A Front Office Room- Sheetrock/Joint Compound Tan None Detected Fibrous Heterogeneous Cellulose100%Non-fibrous (other)0% 05-01-Joint Compound 221202660-0017B Front Office Room- Sheetrock/Joint Compound White None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 05-01-Drywall 221202660-0017C Front Office Room- Sheetrock/Joint Compound Brown/White None Detected Fibrous Heterogeneous Cellulose10%Non-fibrous (other)90% 05-02-Texture 221202660-0018 Front Office Room- Sheetrock/Joint Compound White None Detected Inseparable paint / coating layer included in analysis Non-Fibrous Heterogeneous Non-fibrous (other)100% 6Test Report PLM-7.16.0 Printed: 7/19/2012 9:27:59 AM Erin Orthun, Laboratory Manager or other approved signatory Analyst(s) EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0 Report Amended: 07/19/2012 09:27:59 Replaces the Inital Report 07/18/2012 16:15:12. Reason Code: Client-Change to Appearance Erin Orthun (50) Michael DeCavallas (29) EMSL Analytical, Inc. 1010 Yuma Street, Denver, CO 80204 Phone/Fax:(303) 740-5700 / (303) 741-1400 http://www.emsl.com denverlab@emsl.com 221202660 CustomerID:INES78 CustomerPO: ProjectID: EMSL Order: Attn:Quentin Danziger Indoor Environmental Services, Inc. P.O. Box 997 Vail, CO 81658 Received:07/18/12 8:30 AM Gorsuch Offices Vail Fax: Phone:(970) 390-0087 Project: 7/18/2012Analysis Date: 7/17/2012Collected: Sample Description Appearance % Type AsbestosNon-Asbestos % Fibrous % Non-Fibrous Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy 10-02-Mastic 221202660-0033A Shop-Speckled Green Vinyl Flooring Tan None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 10-03-Linoleum 221202660-0034 Shop-Speckled Green Vinyl Flooring Tan/Green None Detected Fibrous Heterogeneous Cellulose15%Non-fibrous (other)85% 10-03-Mastic 221202660-0034A Shop-Speckled Green Vinyl Flooring Tan None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 11-01 221202660-0035 Shop-Dark Green Vinyl Flooring Gray/Tan None Detected Fibrous Heterogeneous Cellulose15%Non-fibrous (other)85% 11-02 221202660-0036 Shop-Dark Green Vinyl Flooring Gray/Tan None Detected Fibrous Heterogeneous Cellulose15%Non-fibrous (other)85% 11-03-Linoleum 221202660-0037 Shop-Dark Green Vinyl Flooring Gray/Tan None Detected Fibrous Heterogeneous Cellulose15%Non-fibrous (other)85% 11-03-Mastic 221202660-0037A Shop-Dark Green Vinyl Flooring Tan None Detected Non-Fibrous Homogeneous Non-fibrous (other)100% 11THIS IS THE LAST PAGE OF THE REPORT.Test Report PLM-7.16.0 Printed: 7/19/2012 9:27:59 AM Erin Orthun, Laboratory Manager or other approved signatory Analyst(s) EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0 Report Amended: 07/19/2012 09:27:59 Replaces the Inital Report 07/18/2012 16:15:12. Reason Code: Client-Change to Appearance Erin Orthun (50) Michael DeCavallas (29) ROCKY MOUNTAIN ABATEMENT, INC.  PO BOX 621840  LITTLETON, CO 80162  TELEPHONE: 303‐932‐1767  FAX: 303‐972‐2907  RMtnAbatement@comcast.net    IN CONSIDERATION of the services and materials to be provided to the purchaser by Rocky Mountain  Abatement, Inc. ("Contractor") , and the mutual covenants contained herein, this Proposal shall become  a contract between parties upon acceptance by Purchaser.  This Proposal includes labor, material, equipment, permits, and fee's required for the completion of this  project described in the Scope of Work.  The owner will provide all water and electricity necessary for this project.  Final air sampling is not included in the contract price.  Asbestos waste will be taken to a EPA approved landfill.  The owner shall vacate and remove all movable items from the work area before and during the  project.  The removal and disposal work will be done in compliance with Federal, State and local regulations.  Rocky Mountain Abatement, Inc will provide liability and workers compensation insurance.  Rocky Mountain Abatement, Inc is not responsible for damage to walls or ceilings affected by the  containment.    A finance charge of 1.5% per month will be added for unpaid balances. Customer is responsible for  payment of all costs of collection of past due accounts, including court costs, finance charges and  attorney fees.  PROPOSAL TO: George Shaeffer Construction  PO Box 373 Vail, CO 81658    TELEPHONE: 970‐790‐1512  FAX:970‐790‐1523  kevins@gsconco.com    DATE: 07/23/12      JOB LOCATION: Gorsuch  offices  SCOPE OF WORK TO BE PERFORMED:  1st level  Office area, Removal of carpet and mastic , the carpet will also be asbestos containing, removal  of the wall board where electrical conduit is present some two foot flood cut and four in flood cut  includes storage closet.          Contract Price: $6640.00  Final air clearance: $800.00    TOTAL COST: $7440.00    EXCLUSION:   Any asbestos containing material not in the scope of work.  TERMS AND CONDITIONS OF PAYMENT: Payment Due upon completion of the project.  The Above Proposal shall remain in effect  for 30 days, but shall expire if not accepted by Purchaser  within such period.  Rocky Mountain Abatement, Inc.  By:__________________________  Title:________________________  The above proposal is herby accepted this______ day of__________________________,     by,______________________________________, an authorized agent of  Purchaser:________________________________,    Purchaser,________________________________,  _____________________________________________________________________________________  (Insert Purchaser's correct entity name above)    By,_______________________________________,    Title,_____________________________________,