HomeMy WebLinkAboutA12-0039 DATA SHEETSDF-52418:D • 02/22/2011 — Page 1 of 4 MS-9050UD(E) Fire Alarm Control Panel with DACT Addressable DF-52418:D • A1-20 52 4 1 8 c o v . j p g General The Fire•Lite MS-9050UD(E) is a Fire Alarm Control Panel (FACP) and Digital Alarm Communicator/Transmitter (DACT) combined into one circuit board. This compact, intelligent addressable control panel supports up to 50 addressable devices of any type of detectors and modules. With an exten- sive list of powerful features, the MS-9050UD programs just like Fire•Lite’s larger products, yet fits into applications previously served only by conventional panels. The MS-9050UD’s integral DACT transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the pub- lic switched telephone network. It also allows remote and local programming of the control panel using the PK-CD Upload/ Download utility. In addition, the control panel may be pro- grammed or interrogated off-site via the public switched tele- phone network. Any personal computer with Windows™ 95 or greater, and compatible modem with a speed of 14.4 kbps or faster and Fire•Lite Upload/Download software kit PK-CD, may serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history file, walk-test data, current status and system voltages. The power supply and all electronics are contained on a single circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polarity/city box transmitter. (4XTMF) New options include a UL listed printer, PRN-6F and the new IPDACT Internet Monitoring module.The FireWatch Series inter- net monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet, saving the monthly cost of two telephone lines. Although not required, the second- ary telephone line may be retained providing backup communi- cation over the public switched telephone line. NOTE: Unless otherwise specified, the term MS-9050UD is used in this data sheet to refer to both the MS-9050UD and the MS- 9050UDE FACPs. For MS-9050UDC, refer to DF-60445. Features •Listed to UL Standard 864, 9th edition. •Auto-program (learn mode) reduces installation time. Reports two devices set to the same address. •On-board DACT. •Two independently programmable Style Z (Class A) or Style Y (Class B) NAC circuits. •Selectable strobe synchronization for System Sensor, Whee- lock, and Gentex devices. •Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules. •Two programmable relays and one fixed trouble relay. •Built-in Programmer. •Telephone Line Active LEDs. •EIA-232 PC interface. •Integral 80-character LCD display with backlighting. •Real-time clock/calendar with automatic daylight savings control. •History file with 500 event capacity. •Automatic detector sensitivity testing (NFPA 72 compliant). •Automatic device type-code verification. •Point trouble identification. •Waterflow selection per module point. •Alarm verification selection per detector point. •Maintenance alert warns when smoke detector dust accumu- lation is excessive. •One-person audible or silent walk test with walk-test log and printout. •System alarm verification selection per detector point. •PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant). •Up to eight ANN-BUS annunciators •Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator. •Upload/Download (local or remote) of program and data via integral DACT. SLC COMMUNICATION LOOP •Single addressable SLC loop which meets NFPA Style 4, 6 and 7 requirements. •50 addressable device capacity (any combination of address- able detectors and modules). •Compatible with Fire•Lite’s addressable devices (refer to SLC Wiring Manual). NOTIFICATION APPLIANCE CIRCUITS (NACS) •Two independently programmable output circuits. Circuits can be configured for the following outputs: –Style Y (Class B) –Style Z (Class A) –Door Holder Service (cannot be used for notification appliances) –Aux Power Source (cannot be used for notification appliances) •Silence Inhibit and Autosilence timer options. •Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. •Selectable strobe synchronization per NAC. •2.5A total power for NACs. NOTE: Maximum or total 24VDC system power shared between all NAC circuits and the ANN-BUS is 2.7A. By David Rhoades at 4:12 pm, Aug 01, 2012 Page 2 of 4 — DF-52418:D • 02/22/2011 PROGRAMMING AND SOFTWARE •Autoprogram (learn mode) reduces installation time. •Custom English labels (per point) may be manually entered or selected from an internal library file. •Two programmable Form-C relay outputs. •20 software zones. •Continuous fire protection during online programming at the front panel. •Program Check automatically catches common errors not linked to any zone or input point. •OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package(order programming kit PK-CD, containing PK-Plus, separately). Upload/download system programming locally. User interface LED INDICATORS •AC Power (green) •Fire Alarm (red) •Supervisory (yellow) •Trouble (yellow) •Alarm Silenced signals (yellow) KEYPAD •16 key alpha-numeric pad •Acknowledge/Step •Alarm Silenced •Drill (Manual Evacuate) •Reset (lamp test) Product Line Information MS-9050UD(E): Combination DACT/Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, chassis with transformer, backbox with door, plastic bag contain- ing screws, cables, key, etc., manual. (For MS-9050UDC, refer to DF-60445.) PK-CD: Contains PK-Plus programming software for Win- dows®-based PC computer (cable not included). DP-51050: Optional dress panel for the MS-9050UD. TR-CE: Optional trim ring for semi-flush mounting. BB-2F: Optional cabinet for one or two modules. BB-6F: Optional cabinet for up to six modules mounted on CHS-6 chassis. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55F: Battery box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi-modules in a BB-6F cabinet. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead-acid bat- teries with a rating of 55 to 120 AH. Requires additional BB-55F for mounting. BAT Series: Batteries, see data sheet DF-52397. PRT/PK-CABLE: Cable printer/personal computer interface cable. PRN-6F: UL listed compatible event printer. Uses tractor-fed paper. IPDACT, IPDACT-2/2UD Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT telephone output ports for internet communications over customer provided ether- ADDRESSABLE FIREALARM CONTROLPANEL MS-9050UD MS-9050UD Fire Alarm Control Panel pooL C L S SD355 Photo Detector AD355 AdaptDetector MMF-300 Monitor Module P2R Strobe P2R Strobe MMF-302 2-Wire Detector Monitor Module BG-12LX Addressable Manual Pull Station Power Supply FCPS-24FS6 FCPS-24FS8 SD355T Photo/Thermal ANN-80 MDF-300 Dual Monitor Module H355/H355R/H355HT Heat Detector D355PL Duct Detector Multi-Modules •CRF-300-6 Six-Relay Control Module •CMF-300-6 Six-Circuit Supervised Control Module •MMF-302-6 Six-Zone Interface Module •MMF-300-10 Ten-Input Monitor Module P2R Strobe Beam Detector BEAM-335/(S) Printer Gateway ANN-S/PG Graphic LED Module Relay Module ANN-RLY ANN-I/O DF-52418:D • 02/22/2011 — Page 3 of 4 net internet connection. Requires compatible Teldat Visoralarm Central Station Receiver. Can use DHCP or static IP. (See data sheet df-52424 for more information.) IPBRKT: Mounting kit for IPDACT-2/2UD in common enclosure. IPSPLT: Y-adaptor option allows connection of both panel dialer outputs to one IPDACT-2/2UD cable input. AC-TRMBLK: AC Terminal Block mounts to a metal bracket, in turn, mounts to the FACP chassis. Use AC-TRMBLK when wire nuts are not allowed for AC connections to the transformer. OPTIONAL MODULES 4XTMF Reverse Polarity Transmitter Module: Provides a supervised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. ANN-SEC: Optional secondary ANN-BUS interface module. Note: Used only with firmware 3.0 or higher. COMPATIBLE ANNUNCIATORS ANN-80(-W): Remote LCD annunciator mimics the information displayed on the FACP LCD display. Recommended wire type is un-shielded. (Basic model is red; order -W version for white; see DF-52417.) ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DF-52430.) ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclo- sure. (See DF-60241.) ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF-60241.) ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DF-52431.) ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DF-52429.) ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. CP355: Addressable low-profile ionization smoke detector. SD355: Addressable low-profile photoelectric smoke detector. SD355T: Addressable low-profile photoelectric smoke detector with thermal sensor. SD355R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of- rise option. H355HT: Fast-response, low-profile heat detector that activates at 190°F/88°C. AD355: Low-profile, intelligent, “Adapt” multi-sensor detector (B350LP base included). BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sen- sitivity test. D355PL: InnovairFlex low-flow non-relay duct-detector housing; includes SD355R. DNR: InnovairFlex low-flow non-relay duct-detector housing. (Order SD355R separately.) DNRW: InnovairFlex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order SD355R separately.) MMF-300: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it provides two Style B (Class B) only IDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302A: Similar to MMF-300A. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires reset- table 24 VDC power. Refer to the Device Compatibility Docu- ment for listed compatible devices and quantity limitation. CMF-300: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power noti- fication appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. BG-12LX: Addressable manual pull station with interface mod- ule mounted inside. I300: This module isolates the SLC loop from short circuit condi- tions (required for Style 6 or 7 operation). SMB500: Used to mount all modules except the MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two mod- ules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. MMF-302-6: Six-zone interface module. Mount one or two mod- ules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F cabinet. CRF-300-6: Six-relay control module (Form-C relays). Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. NOTE: For more information on Compatible Addressable Devices for use with the MS-9050UD, see the following data sheets (docu- ment numbers): AD355 (DF-52386), BG-12LX (DF-52013), CMF- 300-6 (DF-52365), CRF-300-6 (DF-52374), CMF/CRF Series (DF- 52130), CP355 (DF-52383), H355 Series (DF-52385), I300 (DF- 52389), MMF-300 Series/MDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF-302-6 (DF-52356), SD355/SD355T (DF- 52384). ADDRESSABLE DEVICE ACCESSORIES End-of-Line Resistor Assembly (R-47K and R-3.9K): The 47kohm assembly supervises the MMF-300, MDF-300, MMF- 301, and CMF-300 module circuits. The 3.9kohm assembly supervises the MMF-302 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Refer to the panel manual for wiring details. Page 4 of 4 — DF-52418:D • 02/22/2011 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Made in the U.S. A. System Capacity •Intelligent Signalling Line Circuits.........................................1 •Addressable device capacity..............................................50 •Programmable software zones...........................................20 •Annunciators.........................................................................8 Electrical Specifications AC Power: MS-9050UD 120 VAC, 60 Hz, 3.0A. MS-9050UDE: 240 VAC, 50 Hz, 1.5A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, supervised. Battery: Two 12 V 18AH lead-acid batteries. Battery Charger Capacity: 7-18AH (MS-9050UD cabinet holds maximum of two 18AH batteries.) Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Terminal Block provides con- nections for two NACs, Style Y (Class B) or Style Z (Class A). Special Application power. Power-limited, supervised circuitry. Maximum signaling current per circuit: 2.5A. End-of-Line Resis- tor: 4.7kohm, ½ watt (P/N 71252 UL listed) for Style Y (Class B) NAC. Refer to the Fire•Lite Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0A @ 30 VDC (resistive), 0.5A @ 30 VAC (resistive). Form-C relays, nonpower-limited, nonsupervised. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00” (50.80 cm.) high x 22.5” (57.15 cm.) wide x 8.5” (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (non- condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic compo- nents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. NFPA Standards The MS-9050UD(E) complies with the following NFPA 72 Fire Alarm Systems requirements: –LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). –AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). –REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) –PROPRIETARY (Automatic, Manual and Waterflow). –CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). –OT, PSDN (Other Technologies, Packet-switched Data Net- work) Agency Listings and Approvals The listings and approvals below apply to the basic MS- 9050UD(E) control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. •UL: S624 •FM approved •CSFM: 7165-0075:210 •MEA: 442-06-E NOTE: See DF-60445 for ULC-listed model. FireLite® Alarms® and System Sensor® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. ©2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. SYSTEM SPECIFICATIONS P R O D U C T I N F O R M A T I O N B U L L E T I N 449/448 SERIES Self-Diagnostic, Four- Wire, Photoelectric Smoke Detectors Model numbers: 449AT, 449C, 449CT, 449CRT, 449CST, 449CSTE, 449CSRT, 449CSRH, 449CTE •Intelligent, self-diagnostics • On-site maintenance alert •Field replaceable optical chamber •Low-profile design •Plug-in terminal block •Advanced false alarm immunity The ESL 449/448 Series self-diagnostic, four-wire smoke detectors continually monitor their own sensitivity and operational status, and provide a visual trouble indication if they drift out of sensitivity range or fail internal diagnostics. This unique, patented technology meets NFPA 72 field sensitivity testing requirements without the need for external meters. Additional diagnostic information is activated by applying a magnet near the detector's integral reed switch. This initiates a self-diagnostic routine and provides visual indication of sensitivity level, or if service is required. This series is easily cleaned by simply replacing ESL’s proprietary field-replaceable optical chamber. All models are designed to reduce false alarms from dust, insects, RFI, and external light. An integral combination rate-of-rise and fixed 135°F (57°C), 50-foot rated, heat sensor is available with all “T” model detectors (see selection guide), allowing latching of the alarm for either smoke or heat. The 449CSRH includes an isolated alarm output for heat and activates an internal non-latching sounder (local alarm) for smoke, making it ideal for motel/hotel and dormitory rooms where smoking is permitted. California State Fire Marshal Approved MEA (New York City) Approved ULC model numbers: 448AT, 448C, 448CT, 448CST, 448CSRH, 448CTE continued E-3965 Rev B-1101 PH 503.692.4052 USA & Canada: 800.547.2556 Technical Service: 800.648.7424 FaxBack: 800.483.2495 www.sentrol.com www.interlogixsecurity.com ©2001 Interlogix, Inc. Interlogix, Caddx, ESL, ITI and Sentrol are trademarks of Interlogix,Inc. Architectural and Engineering Specifications The ESL 449 Series low-profile, self-diagnostic, four-wire smoke detectors work on the light scattering principle. A pulsed infrared light-emitting diode serves as the light source, and a high-speed photodiode as the sensing element. When the amount of light reflected onto the photodiode reaches the sensitivity setting, the smoke sampling rate increases. Three (3) successive smoke sensings above the sensitivity setting are required to sound an alarm. This design has superior protection against false alarms caused by dust, insects, RF and ambient-light. A confirmed alarm causes the normally flashing power indicator LED to light continuously and the alarm relay to operate. A trouble indication is automatically displayed by flashing the LED every second. This meets NFPA 72 field sensitivity testing requirements. An internal 85 dB horn (available in “S” models) emits a temporal 3 when the detector alarms and a steady tone when power polarity is reversed. ESL 449 Series Smoke Detectors Product Data Sensitivity.................................................3.1 - 1.0%/ft. (max.) 3.1 + 0.50%/ft. (min) Operating temp. range...............32°F to 120°F (0°C to 50°C) Operating humidity range....................................0 to 95% RH Minimum voltage - C, CT, CRT, CST, CSRT, CSRH , - CSTE.........................................................................8.5V - AT..............................................................................5.1V Maximum voltage - C, CT, CRT, CST, CSRT, CSRH, - CSTE...........................................................................33V - AT................................................................................27V Maximum ripple (peak to peak)........................................10% Typical average standby current.....................................70µA - CSTE........................................................................23mA Typical alarm current - C, CT and AT............................15mA - CRT..........................................................................31mA The proprietary optical sensing chamber is field replaceable, allowing quick and easy cleaning and maintenance. Models with auxiliary relays are approved for releasing service. This low profile product is equipped with a hinged cover, a concealed tamper-resistant latch, and insect screens. Wiring terminates in plug-in, clamp-type screw terminals. Detectors mount to a standard single-gang electrical box, a four-inch octagonal, four-inch square electrical box, or WIREMOLD 5739 fixture box. Smoke Detector Spacing On smooth ceilings (as defined in NFPA 72), spacing of 30 feet (9.1 meters) may be used as a guide. Other spacing may be used depending on ceiling height, high air movement, and other conditions or response requirements. - CST..........................................................................40mA - CSRT, CSRH, CSTE................................................51mA Typical avg. polarity reverse current - CST, CSRT, CSTE, and CSRH................................10mA Sounder specifications.........................................85 dB at 10' Heat detector specifications - fixed temperature..................................... 135°F (57.2°C) - rate of rise....15°F/min. & >105°F (8.3°C/min. & >40.6°C) Auxiliary relay contacts2A @ 28 VDC or 120 VAC (resistive) Alarm contacts........................ 500 mA @ 36 VDC (resistive) Field wiring size..................................................14 - 24 AWG Packaging.......................10 detectors are packed in a carton Color....................................................white cover/white base with UV inhibitor to prevent yellowing Listing.............................. UL 268, ULC FM, CSFM and MEA Selection Guide DesignatorFeatureDescription H Isolated Fixed Temp.Isolated fixed 135°F (57°C) and rate of rise heat detector, independently trips the LED and alarm and Rate of Riseoutput. Smoke detector activates internal sounder (local alarm) and auxiliary relay, but Heat Detector does not latch. Approved as both single station smoke alarm and system heat detector. Ideal for hotel, motel and dormitory rooms where smoking is allowed. R Auxiliary RelayUsed to activate other devices such as elevator recall, door holders, strobes, etc. Listed for releasing service. S Built-in Sounder85dB built-in sounder alarms when smoke is detected or when power wiring polarity is reversed. T Intergrated FixedIntergrated Fixed 135°F (57°C) temperature and rate of rise heat detector. Temp. and Rate ofEither heat detector or smoke detector can trip and latch LED and alarm protection. Rise Heat Detectorrelay outputs. E Built-in end of lineRelay is normally energized and will trip with loss of power. Can also provide notification power supervision relaywhen detector needs maintenance. Agency Listings CO1224T Carbon Monoxide Detector with RealTest™ Technology The System Sensor CO1224T CO detector provides early warning by using electrochemical sensing technology to measure carbon monoxide levels in the air. Features RealTest• ™ technology allows installer to test detector with CO gas Full compliance with UL 2075• A code required trouble relay• Wiring supervision with SEMS terminals• A six year end-of-life timer• 12/24 VDC• A current draw of 20mA in standby and 40mA in alarm• Versatile mounting for wall and ceiling• Electrochemical sensing technology• With RealTest™ technology, the CO gas sensing cell of the CO1224T CO detector can be tested using a carbon monoxide gas agent. Simply hold the test button for two seconds. After the alarm cycle (temp 4) the green LED will flash about once per second, indicating that the detector is ready to accept CO for testing. Spray a small amount of CO into the detector per the installation instructions, and within seconds the detector will alarm, indicating successful gas entry. If dangerous amounts of carbon monoxide is detected, the CO1224T detector will alert residents by sounding and flashing a temp-4 signal alarm. Protection is guaranteed 24/7 by a central station, regardless of whether residents are away from home, sleeping or already suffering from the effects of CO. This specific device is designed for system operation. The detector is fully listed to UL 2075. It offers a code required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station. It also uses SEMS-type terminal Philips head screws to provide a quicker and more positive wiring connection and code required wiring supervision. The CO1224T detector offers a low current draw, allowing more devices to be connected to the panel without having to purchase a more expensive panel or an extra power supply. The CO1224T model will operate on most industry security and fire alarm control panels because it is is a 12/24 VDC detector. 2075 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2008 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0437-000 • 8/08 • #1953 Ordering Information Part No.Description CO1224T 12/24 volt, 4-wire system-monitored carbon monoxide detector with RealTest™ Technology CO1224T Carbon Monoxide Detector Specifications Architectural/Engineering Specifications Carbon monoxide detector shall be a System Sensor model number CO1224T, listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors. The detector shall be equipped with a sounder and a trouble relay. The detector’s base shall be able to mount to a single-gang electrical box or direct (surface) mount to the wall or ceiling. Wiring connections shall be made by means of SEMS screws. The detector shall provide dual color LED indication, which blinks to indicate normal standby, alarm, or end-of-life. When the sensor supervision is in a trouble condition, the detector shall send a trouble signal to the panel. When the detector gives a trouble or end-of-life signal, the detector shall be replaced. The detector shall provide a means to test CO gas entry into the CO sensing cell. The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. Electrical Specifications Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA (75 mA test) Alarm Contact Ratings 0.5 A @ 30 VDC Trouble Contact Ratings 0.5 A @ 30 VDC Physical Specifications Size Length: 5.1 in, Width: 3.3 in, Height: 1.3 in Approximate Weight 7 oz Operating Temperature Range 32°F to 104° F (0°C to 40° C) Operating Humidity Range 22 to 90% RH Input Terminals 14 to 22 AWG Mounting Single-gang back box; surface mount to wall or ceiling Operation Modes Operation Mode Green LED Red LED Sounder Normal (standby)Blink 1 per minute —— Alarm —Blink in temp 4 pattern Sound in temp 4 pattern RealTest™ Feature: The System Sensor CO1224T carbon monoxide detector with RealTest™ can evaluate the functionality of the CO sensing cell using canned test agent. NOTE: Check with local codes and the AHJ to determine whether or not a functional gas test is desired for an installation. Hush Feature: Pushing the Test/Hush button will silence the sounder for 5 minutes (except in RealTest mode). Trouble Feature: When the detector is in a trouble condition, it will send a trouble signal to the panel. End-of-life Timer: After the detector’s internal sensor has reached the end of its life, a trouble signal will be sent to the panel. This will indicate that it is time to replace the detector. An electrochemical carbon monoxide detector lifespan is approximately six years, and the detector must be replaced by the date marked on the inside of the product. 1.2.3. Push and hold the Test/Hush button for two seconds to enter RealTest mode. The green LED will flash once every second to indicate RealTest mode has started. Spray canned CO agent into the detector.Verify CO sensing at the control panel. The detector will automatically exit RealTest alarm mode after about 20-60 seconds. DF-52121:C • 10/06/2010 — Page 1 of 4 MMF-300(A) Series, MDF-300(A) Addressable Monitor Modules Addressable Devices DF-52121:C • E-325 General Four different monitor modules are available for Fire•Lite’s intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302(A)). MMF-300(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. MMF-301(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D used to super- vise a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the MMF-301(A) to be mounted in a single-gang box behind the device it monitors. MMF-302(A) is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. MDF-300(A) is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems. LiteSpeed™ is a communication protocol developed by Fire•Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. designs. MMF-300(A) Monitor Module •Built-in type identification automatically identifies this device as a monitor module to the control panel. •Powered directly by two-wire SLC loop. No additional power required. •High noise (EMF/RFI) immunity. •SEMS screws with clamping plates for ease of wiring. •Direct-dial entry of address: 01 – 159 on MS-9600 series panels, 01 – 99 on other compatible systems. •LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-300(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300(A) OPERATION Each MMF-300(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-300(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 μA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MMF-300(A) (TypeH) 69 9 9 c o v . j p g Page 2 of 4 — DF-52121:C • 10/06/2010 MMF-301(A) Mini Monitor Module •Built-in type identification automatically identifies this device as a monitor module to the panel. •Powered directly by two-wire SLC loop. No additional power required. •High noise (EMF/RFI) immunity. •Tinned, stripped leads for ease of wiring. •Direct-dial entry of address: 01 – 159 on MS-9600 series panels, 01 – 99 on other compatible systems The MMF-301(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The MMF-301(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A) can be used to replace M301(A) modules in existing systems. MMF-301(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. MMF-301(A) OPERATION Each MMF-301(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). MMF-301(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 μA, 1 communication every 5 seconds, 47k EOL; 600 μA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 μA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. MMF-302(A) Interface Module •Supports compatible two-wire smoke detectors. •Supervises IDC wiring and connection of external power source. •High noise (EMF/RFI) immunity. •SEMS screws with clamping plates for ease of wiring. •Direct-dial entry of address: 01 – 159 on MS-9600 series panels, 01 – 99 on other compatible systems. •LED flashes during normal operation. •LED latches steady to indicate alarm on command from control panel. The MMF-302(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The MMF- 302(A) can be used to replace M302(A) modules in existing systems. MMF-302 (A) APPLICATIONS Use the MMF-302(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302(A) OPERATION Each MMF-302(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-302(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 μA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. 67 2 0 m 1 0 1 . w m f DF-52121:C • 10/06/2010 — Page 3 of 4 MDF-300(A) Dual Monitor Module The MDF-300(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The MDF-300(A) provides two Style B (Class B) IDC cir- cuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. MDF-300(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 μA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 μA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm) deep. MDF-300(A) AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address “26”, then it will automati- cally assign itself to addresses “26” and “27”. NOTE: “Ones” addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wiring only. The MMF-301(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. •UL: S2424 •ULC: S2424 •FM Approved •CSFM: 7300-0075:0185 •MEA: 72-01-E Product Line Information NOTE: “A” suffix indicates ULC-listed model. MMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module, two-wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51309. Architects’/Engineers’ Specifications Specifications of these devices and all FireLite products are available from FireLite. !CAUTION: Avoid duplicating addresses on the system. Page 4 of 4 — DF-52121:C • 10/06/2010 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Fire·Lite® and LiteSpeed® are registered trademarks and FireWatch™ is a trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Made in the U.S. A. DF-52347:A • 05/15/2009 — Page 1 of 2 MMF-300-10(A) Ten-Input Monitor Module Addressable Devices DF-52347:A • E-900 General The MMF-300-10 ten-input monitor module is an interface between a control panel and normally open contact devices in intelligent alarm systems such as pull stations, security contacts, or flow switches. The first address on the MMF-300-10 is set from 01 to 150 and the remaining modules are automatically assigned to the next nine higher addresses. Provisions are included for dis- abling a maximum of two unused addresses. The supervised state (normal, open, or short) of the moni- tored device is sent back to the panel. A common SLC input is used for all modules, and the initiating device loops share a common supervisory supply and ground — otherwise each monitor operates independently from the others. Each MMF-300-10 module has panel-controlled green LED indicators. The panel can cause the LEDs to blink, latch on, or latch off. NOTE: Unless otherwise specified, the term MMF-300-10 is used in this data sheet to refer to both the MMF-300-10 and the MMF- 300-10A (ULC-listed version). Features •Listed to UL Standard 864, 9th edition. •Ten addressable Class B or five addressable Class A initi- ating device circuits. •Removable 12 AWG (3.25 mm²) to 18 AWG (0.9 mm²) plug-in terminal blocks. •Status indicators for each point. •Unused addresses may be disabled. •Rotary address switches. •Class A or Class B operation. •Flexible mounting options. •Mounting hardware included. Specifications Standby current: 3.5 mA (SLC current draw with all addresses used; if some addresses are disabled, the standby current decreases). Alarm current: 55 mA (assumes all ten LEDs solid ON). Temperature range: 32°F to 120°F (0°C to 49°C) for UL applications; –10°C to +55°C for EN54 applications. Humidity: 10% to 85% noncondensing for UL applications; 10% to 93% noncondensing for EN54 applications. Dimensions: 6.8" (172.72 mm) high x 5.8" (147.32 mm) wide x 1.25" (31.75 mm) deep. Shipping weight: 0.76 lb. (0.345 kg) including packaging. Mounting options: –CHS-6 chassis: Up to 6 modules. –BB-6F cabinet: Up to 6 modules. –BB-2F cabinet: One or two modules. Wire gauge: 12 AWG (3.25 mm²) to 18 AWG (0.9 mm²). Power-limited circuits must employ type FPL, FPLR, or FPLP cable as required by Article 760 of the NEC. MMF-300-10 is shipped in Class B position; remove shunt for Class A operation. Maximum SLC wiring resistance: 40 or 50 ohms, panel dependent. Maximum IDC wiring resistance: 1500 ohms. Maximum IDC voltage: 10.2 VDC. Maximum IDC current: 240 µA. 69 2 3 x p 1 0 . j p g Page 2 of 2 — DF-52347:A • 05/15/2009 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com FireLite® Alarms® and System Sensor® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Made in the U.S. A. Agency Listings and Approvals The listings and approvals below apply to the MMF-300- 10(A)Ten-Input Monitor Module. In some cases, certain mod- ules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for lat- est listing status. •UL Listed: S2424 •ULC Listed: S2424 •CSFM approved: 7300-0075:205 •FM approved •MEA approved: 55-02-E Product Line Information MMF-300-10: Ten-input monitor module. MMF-300-10A: Same as above with ULC Listing. BB-2F: Optional cabinet for one or two modules. Dimen- sions, DOOR: 9.234" (23.454 cm) wide (9.484" [24.089 cm] including hinges), x 12.218" (31.0337 cm) high, x 0.672" (1.7068 cm) deep; BACKBOX: 9.0" (22.860 cm) wide (9.25" [23.495 cm] including hinges), x 12.0" (30.480 cm) high x 2.75" (6.985 cm); CHASSIS (installed): 7.150" (18.161 cm) wide overall x 7.312" (18.5725 cm) high interior overall x 2.156" (5.4762 cm) deep overall. BB-6F: Optional cabinet for up to six modules mounted on CHS-6 chassis (below). Dimensions, DOOR: 24.0" (60.96 cm) wide x 12.632" (32.0852 cm) high, x 1.25" (3.175 cm) deep, hinged at bottom; BACKBOX: 24.0" (60.96 cm) wide x 12.550" (31.877 cm) high x 5.218" (13.2537 cm) deep. CHS-6: Chassis, mounts up to six modules in BB-6F.