Loading...
HomeMy WebLinkAboutDRB120342 Project Name:PW LUNCHROOM WINDOWS DRB Number: DRB120342 Project Description: REPLACE EXISTING THREE WINDOWS WITH LIKE MATCHING WINDOWS. SIZE AND COLOR TO MATCH. Participants: OWNER TOWN OF VAIL 08/03/2012 75 S FRONTAGE RD VAIL CO 81657 APPLICANT TOWN OF VAIL 08/03/2012 75 S FRONTAGE RD VAIL CO 81657 Project Address:1289 ELKHORN DR VAILLocation: VAIL PUBLIC WORKS FACILITY 2ND FLOOR LUN Legal Description:Lot: Block: Subdivision: UNPLATTED Parcel Number:2101-092-0000-1 Comments:See conditions BOARD/STAFF ACTION Motion By: Action: STAFFAPP Second By: Vote: Date of Approval: 08/08/2012 Conditions: Cond: 8 (PLAN): No changes to these plans may be made without the written consent of Town of Vail staff and/or the appropriate review committee(s). Cond: 0 (PLAN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to construction activities. Cond: 201 (PLAN): DRB approval shall not become valid for 20 days following the date of approval, pursuant to the Vail Town Code, Chapter 12-3-3: APPEALS. Cond: 202 (PLAN): Approval of this project shall lapse and become void one (1) year following the date of final approval, unless a building permit is issued and construction is commenced and is diligently pursued toward completion. Planner:Warren Campbell DRB Fee Paid: $250.00 D TOWN OF VAI[ �� AUG 0 3 2012 TOWN OF VAIL epartment of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970 -479 -2128 www.vailgov.com Development Review Coordinator Application for Design Review Minor Exterior Alteration General Information: This application is required for all proposals involving minor changes to buildings and site improve- ments, such as roofing, painting, window additions, landscaping, fences, retaining walls, etc. Applicable Vail Town Code sections can be found at www.vailgov.com under Vail Information — Town Code Online. All projects requiring de- sign review must receive approval prior to submitting a building permit application. An application for Design Review cannot be accepted until all required information is received by the Community Development Department, as outlined in the submittal requirements. The project may also need to be reviewed by the Town Council and /or the Planning and Environmental Commission. Design review approval expires one year from the date of approval, unless a building per- mit is issued and construction commences. Fee: $250 for Multi - Family /Commercial $20 for Single Family /Duplex Single Family Description of the Request: Physical Address: Parcel Number: Property Owner: Mailing Address: Multi- Family MCommercial (Contact Eagle Co. Assessor at 970 - 328 -8640 for parcel no.) Phone: Q N — cl 7a - ZJ % CD Owner's Signature: Primary Contact/ O Mailing Address: er Representative: Pho E- MailAtMoOW LJJZL.C&,v Fax: For Office Use Only: Cash_ CC: Visa / MC Last 4 CC # Exp. Date: Auth # Check # Fee Paid: ✓� .� Received From: Meeting Date: DRB No.: ��g � � L'� p� Planner: Project No: PR5 I D — �'4 3 Zoning: Location of the Proposal: Lot Block Land Use: Subdivision:_ 01) PLLQ %TE: (p Property Information Property Address G59 &LL4 �` 6 Parcel # Legal Description Existing Proposed Development Site Area sq ft acres Secondary sq ft buildable sq ft Zone District / SDD # EHU sq ft Hazard Zones Sections 12 -21 & 14 -7 SnowAvolonche ❑ High Severity Moderate Severity FN /A Debris Flow Flow ❑ High g []Moderate Flow E] High Avalanche N/A Rock fall [] High Severity []Medium Severity [ N/A Excessive Slopes [ ?30% [ N/A Floodploin [] 100 year floodplain [ Floodway [] Wetlands [ N/A Creeks, Streams Section 12 -14 -17 Gore Creek ❑ on site ❑ adjacent to site ❑ N/A Other tributary: Elon site E] adjacent to site N/A Project Information Project Description 4tN_& f'3 A'A"i TN UL— `' �lrv�p�g Development Standards Allowed Existing Proposed Gross Residential Floor Area (maximum) Chapter 12 -15 Primary sq ft Secondary sq ft EHU sq ft TOTAL sq ft [1250 Addition ❑ Interior Conversion Credits: Setbacks (minimum) Section 14 -10 -4 Front ft Side ft Side ft Rearft Watercourse ft Site Coverage (maximum) see definition Section 12 -2 -2 Building Height (maximum) see definition Section 12 -2 -2 Sloping ft Flat ft Landscaping See definition Section 14 -2 -1 Section 14 -10 -8 Softscape sq ft Hardscape sq ft TOTAL sq ft Driveway Sections 14 -3 -1 & 14 -3 -2 Max Curb -cuts Max Grade @ cen- terline Min Width Heated drive? Yes []No []Yes No Snow Storage % Parking Sections 12 -10 & 14 -5 #Enclosed Spaces #Unenclosed TOTAL Outdoor Lighting (maximum) Section 14 -10 -7 # fixtures CTB Project Information Project: Fleet Maintainence upper level Sales Rep: Paul Bianchi Delivery / Pickup: Delivery Customer: CRC Design & Remodel Terms: Net 30 Comments: Billing Information Contact: Address: Phone: Fax: Detailed Quote Alpine Lumber 111 E Chambers Ave Eagle, CO 81631 970 - 328 -6306 pblanchi @alpinelumber.com l UNJct Shipping Information Contact: Address: Phone: Fax: Project ID: 102 Quote Date: 02/27/2012 Print Date: 02/27/2012 PO: Est. Delivery: (After Receipt of Order) Quote to: 102 1 Of 6 02/27/2012 Manufacturer: Milgard Item: 0001 Location: upper level garage break room Quantity: 3 SUB UNIT 1 - Essence, 9340, EFCAF, Net 47 3/16" x 53 1/2" UF: 0.24, SGC: 0.23, VLT: 0.40 487.94 NFS:141 9/16" x 77 1/2" SUB UNIT 1 - 1/8" SunCoat Low -E Tempered and 1/8" SunCoat Low -E Tempered 120.65 SUB UNIT 1 - Center Lite Clear Tempered 45.29 SUB UNIT 1 - Triple Glazed 34.18 SUB UNIT 2 - Essence, 9340, EFCAF, Net 47 3/16" x 53 1/2" UF: 0.24, SGC: 0.23, VLT: 0.40 487.94 SUB UNIT 2 - 1/8" SunCoat Low -E Tempered and 1/8" SunCoat Low -E Tempered 120.65 SUB UNIT 2 - Center Lite Clear Tempered 45.29 SUB UNIT 2 - Triple Glazed 34.18 SUB UNIT 3 - Essence, 9340, EFCAF, Net 47 3/16" x 53 1/2" UF: 0.24, SGC: 0.23, VLT: 0.40 487.94 SUB UNIT 3 - 1/8" SunCoat Low -E Tempered and 1/8" SunCoat Low -E Tempered 120.65 SUB UNIT 3 - Center Lite Clear Tempered 45.29 SUB UNIT 3 - Triple Glazed 34.18 SUB UNIT 4 - Essence, 9400, EFA, Net 47 3/16" x 24" UF: 0.25, SGC: 0.19, VLT: 0.33 347.53 SUB UNIT 4 - 1/8" SunCoat Low -E Tempered and 1/8" SunCoat Low -E Tempered 54.76 SUB UNIT 4 - Center Lite Clear Tempered 20.59 SUB UNIT 4 - Triple Glazed 15.65 SUB UNIT 4 - Full Screen w /PureView 20.18 SUB UNIT 5 - Essence, 9400, EFA, Net 47 3/16" x 24" UF: 0.25, SGC: 0.19, VLT: 0.33 347.53 SUB UNIT 5 - 1/8" SunCoat Low -E Tempered and 1/8" SunCoat Low -E Tempered 54.76 SUB UNIT 5 - Center Lite Clear Tempered 20.59 SUB UNIT 5 - Triple Glazed 15.65 SUB UNIT 5 - Full Screen w /PureView 20.18 SUB UNIT 6 - Essence, 9400, EFA, Net 47 3/16" x 24" UF: 0.25, SGC: 0.19, VLT: 0.33 347.53 SUB UNIT 6 - 1/8" SunCoat Low -E Tempered and 1/8" SunCoat Low -E Tempered 54.76 SUB UNIT 6 - Center Lite Clear Tempered 20.59 SUB UNIT 6 - Triple Glazed 15.65 SUB UNIT 6 - Full Screen w /PureView 20.18 COMPOSITE:Total Combination Charge 393.24 COMPOSITE:Special Size Width and Height 41.18 EAWSP 1 2 3 Fin Placement: No fin (block frame); 4 5 6 Even though the diagram of the grids may not line up exactly, manufacturer will line up the grids when being built. " "Verify composite configuration size availability and pricing with your Milgard location. Composite configurations exceeding 40 sq. ft. may require field glazing. Line Item Comments: Item Total Item Quantity Total Customer Approval: 3874.73 11624.19 Initials Quote ID: 102 2 Of 6 02/27/2012 Sub Component Item: HU JIZe =4/ llllb W X54 H Net Size = 47 3/16" W x 53 1/2' Essence, 9340, EFCAF, Net 47 3/16" x 53 1/2" UF: 0.24, SGC: 0.23, VLT: 0.40 1/8" SunCoat Low -E Tempered and 1/8" SunCoat Low -E Tempered Center Lite Clear Tempered Triple Glazed Fin Placement: No fin (block frame); Wall Condition: 5 1/16 "; Exterior Finish: Classic Brown; Interior Finish: Unfinished Pine; Bottom Rail: Short; Glazing: Triple Glazed; Tempered: All; Outer Glass Lite Option: SunCoat Low -E; Inner Glass Lite Option: SunCoat Low -E; Glass Thick 1: 1/8 "; Glass Thick 2: 1/8 "; Center Lite: Clear; Spacer Type: EdgeGardMAX; Breather Tubes: Yes; Even though the diagram of the grids may not line up exactly, manufacturer will line up the grids when being built. "Verify composite configuration size availability and pricing with your Milgard location. Composite configurations exceeding 40 sq. ft. may require field glazing. Sub Component Item: HU Jze =4/ 11 /10 W X54 H Net Size = 47 3/16" W x 53 1/2" Essence, 9340, EFCAF, Net 47 3/16" x 53 1/2* UF: 0.24, SGC: 0.23, VLT: 0.40 1/8" SunCoat Low -E Tempered and 1/8" SunCoat Low -E Tempered Center Lite Clear Tempered Triple Glazed Fin Placement: No fin (block frame); Wall Condition: 5 1/16 "; Exterior Finish: Classic Brown; Interior Finish: Unfinished Pine; Bottom Rail: Short; Glazing: Triple Glazed; Tempered: All; Outer Glass Lite Option: SunCoat Low -E; Inner Glass Lite Option: SunCoat Low -E; Glass Thick 1: 1/8"; Glass Thick 2: 1/8"; Center Lite: Clear; Spacer Type: EdgeGardMAX; Breather Tubes: Yes; Even though the diagram of the grids may not line up exactly, manufacturer will line up the grids when being built. " "Verify composite configuration size availability and pricing with your Milgard location. Composite configurations exceeding 40 sq. ft. may require field glazing. Sub Component Item Total:$ Sub Component Item Quantity Total:$ Sub Component Item Total:$ Sub Component Item Quantity Total:$ 487.94 120.65 45.29 34.18 688.06 688.06 487.94 120.65 45.29 34.18 688.06 688.06 Quote 10: 102 3 Of 6 02/27/2012 Sub Component Item: HUN e= 4/11110 wx04 M Net Size - 47 3/16" W x 53 1/2" Essence, 9340, EFCAF, Net 47 3/16" x 53 1/2" UF: 0.24, SGC: 0.23, VLT:0.40 1/8" SunCoat Low -E Tempered and 1/8' SunCoat Low -E Tempered Center Lite Clear Tempered Triple Glazed Fin Placement: No fin (block frame); Wall Condition: 5 1/16 "; Exterior Finish: Classic Brown; Interior Finish: Unfinished Pine; Bottom Rail: Short; Glazing: Triple Glazed; Tempered: All; Outer Glass Lite Option: SunCoat Low -E; Inner Glass Lite Option: SunCoat Low -E; Glass Thick 1: 1/8 "; Glass Thick 2: 1/8 "; Center Lite: Clear; Spacer Type: EdgeGardMAX; Breather Tubes: Yes; Even though the diagram of the grids may not line up exactly, manufacturer will line up the grids when being built. "Verify composite configuration size availability and pricing with your Milgard location. Composite configurations exceeding 40 sq. ft. may require field glazing. Sub Component Item: s RO Size = 47 11/16"W x 24 1/2" H Essence, 9400, EFA, Net 47 3/16" x 24" UF: 0.25, SGC: Net Size = 47 3/16" W x 24^ H 0. 19, VLT: 0.33 1/8" SunCoat Low -E Tempered and 1/8" SunCoat Low -E Tempered Center Lite Clear Tempered Triple Glazed Full Screen w /PureView Fin Placement: No fin (block frame); Wall Condition: 5 1/16 "; Exterior Finish: Classic Brown; Interior Finish: Unfinished Pine; Bottom Rail: Short; Glazing: Triple Glazed; Tempered: All; Outer Glass Lite Option: SunCoat Low -E; Inner Glass Lite Option: SunCoat Low -E; Glass Thick 1: 1/8 "; Glass Thick 2: 1/8 "; Center Lite: Clear; Spacer Type: EdgeGardMAX; Operating Hardware: None; Hardware Finish: Clay; Screen: Full Screen w /PureView; Breather Tubes: Yes; Extension pole & hex adapter may be needed if Awning is out of reach. Even though the diagram of the grids may not line up exactly, manufacturer will line up the grids when being built. "Verify composite configuration size availability and pricing with your Milgard location. Composite configurations exceeding 40 sq. ft. may require field glazing. 487.94 120.65 45.29 34.18 Sub Component Item Total:$ 688.06 Sub Component Item Quantity Total:$ 688.06 347.53 54.76 20.59 15.65 20.18 Sub Component Item Total:$ 458.71 Sub Component Item Quantity Total:$ 458.71 Quote ID: 102 4 Of 6 02127/2012 Sub Component Item: Ro Size = 47 11/16" W x 24 1/2• H Essence, 9400, EFA, Net 47 3/16" x 24" UF: 0.25, SGC: Net Size = 47 3/16" W x 24" H 0. 19, VLT: 0.33 1/8" SunCoat Low -E Tempered and 1/8" SunCoat low -E Tempered Center Lite Clear Tempered Triple Glazed Full Screen w /PureView Fin Placement: No fin (block frame); Wall Condition: 5 1/16 "; Exterior Finish: Classic Brown; Interior Finish: Unfinished Pine; Bottom Rail: Short, Glazing: Triple Glazed; Tempered: All; Outer Glass Lite Option: SunCoat Low -E; Inner Glass Lite Option: SunCoat Low -E; Glass Thick 1: 1/8 "; Glass Thick 2: 1/8 "; Center Lite: Clear; Spacer Type: EdgeGardMAX; Operating Hardware: None; Hardware Finish: Clay, Screen: Full Screen w /PureView; Breather Tubes: Yes; Extension pole & hex adapter may be needed if Awning is out of reach. Even though the diagram of the grids may not line up exactly, manufacturer will line up the grids when being built. " "Verify composite configuration size availability and pricing with your Milgard location. Composite configurations exceeding 40 sq. ft. may require field glazing. Sub Component Item: RO Size = 47 11/16" w x 24 112" H Essence, 9400, EFA, Net 47 3/16" x 24" UF: 0.25, SGQ Net Size - 47 3/16" W x 24" H 0. 19, VLT: 0.33 1/8" SunCoat Low -E Tempered and 1/8" SunCoat Low -E Tempered Center Lite Clear Tempered Triple Glazed Full Screen w /PureView Fin Placement: No fin (block frame); Wall Condition: 5 1/16 "; Exterior Finish: Classic Brown; Interior Finish: Unfinished Pine; Bottom Rail: Short; Glazing: Triple Glazed; Tempered: All; Outer Glass Lite Option: SunCoat Low -E; Inner Glass Lite Option: SunCoat Low -E; Glass Thick 1: 1/8 Glass Thick 2: 1/8"; Center Lite: Clear; Spacer Type: EdgeGardMAX; Operating Hardware: None; Hardware Finish: Clay; Screen: Full Screen w /PureView; Breather Tubes: Yes; Extension pole & hex adapter may be needed if Awning is out of reach. Even though the diagram of the grids may not line up exactly, manufacturer will line up the grids when being built. `"Verify composite configuration size availability and pricing with your Milgard location. Composite configurations exceeding 40 sq. ft. may require field glazing. Other Charges: 347.53 54.76 20.59 15.65 20.18 Sub Component Item Total:$ 458.71 Sub Component Item Quantity Total:$ 458.71 347.53 54.76 20.59 15.65 20.18 Sub Component Item Total:$ 458.71 Sub Component Item Quantity Total:$ 458.71 Quote ID: 102 5 Of 6 02/27/2012 SUBMITTED BY: SUB TOTAL (taxable):$ 11624.19 ACCEPTED BY: SUB TOTAL (non - taxable):$ 0.00 TAXES( 4.400 %):$ 511.46 DATE: GRAND TOTAL:$ 12135.66 Notice (if any): Please note that actual NFRC energy values may vary from those reported in CTB quote due to variations that may occur during the manufacturing process. In most cases variations will be minimal. Please contact your Milgard location with questions or concerns regarding this potential variation. 3 items. ADDITIONAL INFORMATION: This Quote is valid for 30 days. This is an estimate only and does not include delivery charges. I understand that this order will be placed according to these specifications and is non - refundable. Quote IDS 102 6 Of 6 02/27/2012