Loading...
HomeMy WebLinkAboutF12-0041 HYDRAULIC CALCS corrections requiredGRAHAM RESIDENCE Fire Sprinkler Reports for J.L. Viele Constructrion Inc. 2111 North Frontage Road West Suite E Vail, Colorado 81657 USA Prepared By: Bojar Voda Sprinklers R Us, Inc. 0035 Apache Trail Carbondale, CO 81623 (970) 963-8752 7/26/2012 FIRE - Fire Sprinkler Hydraulics Calculation ProgramElite Software Development, Inc. A & A Fire Protection Graham Residence Glenwood Springs, CO 81611 Page 2 General Project Data Report General Data Project Title:Graham ResidenceProject File Name:Graham..fiw Designed By:Bojar VodaDate:7/26/2012 Code Reference:NFPA 13 RApproving Agency: Client Name:J.L. Viele Constructrion Inc.Phone:970.476.3082 Address:2111 North Frontage Road West Suite E City, State Zip Code:Vail, Colorado 81657 USA Company Name:Sprinklers R Us, Inc.Representative:Bojar Voda Company Address:0035 Apache TrailCity And State:Carbondale, CO 81623 Phone:(970) 963-8752 Building Name:Summers Lodge, Unit 3Building Owner:Richard and Kimberly Graham Contact at Building:Scott AshburnPhone at Building: Address Of Building:123 Willow Pl.City, State Zip Code:Vail, Colorado, 81657 Project Data Description Of Hazard:13 RSprinkler System Type:Wet Design Area Of Water Application:943ft²Maximum Area Per Sprinkler:256ft² Default Sprinkler K-Factor:4.90KDefault Pipe Material:BLAZEMASTER CPVC Inside Hose Stream Allowance:0.00gpmOutside Hose Stream Allowance:0.00gpm In Rack Sprinkler Allowance:0.00gpm Sprinkler Specifications Make:TYCOModel:LFII Size:7/16"Temperature Rating:155F NONE Water Supply Test Data Source Of Information: Test Hydrant ID:Date Of Test: Hydrant Elevation:0ftStatic Pressure:130.00psi Test Flow Rate:500.00gpmTest Residual Pressure:100.00psi Calculated System Flow Rate:70.74gpmCalculated Inflow Residual Pressure:58.89psi Available Residual Pressure At System Flow:129.19psi Calculation Project Data Calculation Mode:Demand HMD Minimum Residual Pressure:7.00psiMinimum Desired Flow Density:0.07gpm/ft² Maximum Water Velocity:20.00ft/sMaximum Frictional Loss / 100 feet:20.00psi Number Of Active Nodes:16 Number Of Active Pipes:15Number Of Inactive Pipes:0 Number Of Active Sprinklers:4Number Of Inactive Sprinklers:0 C:\Users\Bojar\Documents\Elite Software\Fire 6 Projects\Graham..fiwThursday, July 26, 2012, 7:09 PM FIRE - Fire Sprinkler Hydraulics Calculation ProgramElite Software Development, Inc. A & A Fire Protection Graham Residence Glenwood Springs, CO 81611 Page 3 Fire Sprinkler Output Data Overall Pipe Output Data Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 14.9032.2017.0212.071.0017.020.050529.750.493 24.9032.2017.3712.561.10117.02-----0.000.000 BLAZEMASTER CPVC1505.7409.750.493 24.9032.2017.3712.561.0017.370.1855811.922.695 30.0032.200.0015.261.10134.39E2.600.000 BLAZEMASTER CPVC15011.59014.522.695 30.0032.200.0015.261.0018.350.205570.671.227 54.9032.2018.3514.031.10136.35T5.300.000 BLAZEMASTER CPVC15012.2505.971.227 44.9032.2017.9913.481.0017.990.055989.750.546 54.9032.2018.3514.031.10117.99-----0.000.000 BLAZEMASTER CPVC1506.0609.750.546 30.0032.200.0015.261.250.000.2233317.835.523 60.0032.200.0020.781.39470.74T6.900.000 BLAZEMASTER CPVC15014.87024.735.523 60.0032.200.0020.781.500.000.1148411.421.311 70.0032.200.0022.091.59870.74-----0.000.000 BLAZEMASTER CPVC15011.32011.421.311 70.0032.200.0022.091.500.000.1148418.172.087 80.0032.200.0024.181.59870.74-----0.000.000 BLAZEMASTER CPVC15011.32018.172.087 80.0032.200.0024.181.500.000.1148410.082.088 90.0032.200.0026.271.59870.74T8.100.000 BLAZEMASTER CPVC15011.32018.182.088 90.0032.200.0026.272.000.000.0382219.081.127 100.0032.200.0027.392.00370.742E10.400.000 BLAZEMASTER CPVC1507.20029.481.127 100.0032.200.0027.392.000.000.040273.500.906 110.0032.200.0028.302.15770.74TB19.000.000 SCHED 10 WET STEEL1206.21022.500.906 110.0032.200.0028.302.500.000.0208527.170.654 120.005.000.0040.732.46970.74E4.2011.778 SCHED 40 STEEL BLK1204.74031.3712.432 120.005.000.0040.732.500.000.0208512.330.697 130.000.000.0043.592.46970.743ET21.102.165 SCHED 40 STEEL BLK1204.74033.432.862 C:\Users\Bojar\Documents\Elite Software\Fire 6 Projects\Graham..fiwThursday, July 26, 2012, 7:09 PM FIRE - Fire Sprinkler Hydraulics Calculation ProgramElite Software Development, Inc. A & A Fire Protection Graham Residence Glenwood Springs, CO 81611 Page 4 Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 130.000.000.0043.592.500.000.020855.500.290 140.000.000.0043.882.46970.742E8.400.000 SCHED 40 STEEL BLK1204.74013.900.290 14 Backflo Prev 0.0043.8870.74 1510.00 psi0.0053.93 15Meter0.0053.9370.74 165.00 psi0.0058.89 C:\Users\Bojar\Documents\Elite Software\Fire 6 Projects\Graham..fiwThursday, July 26, 2012, 7:09 PM FIRE - Fire Sprinkler Hydraulics Calculation ProgramElite Software Development, Inc. A & A Fire Protection Graham Residence Glenwood Springs, CO 81611 Page 5 Fire Sprinkler Output Data Overall Sprinkler Output Data Flowing Sprinkler Node No. Area Group Code Sprinkler KFactor (K) Sprinkler Elevation (feet) Residual Pressure (psi) Flowing Area (ft²) Flowing Density (gpm/ft²) Sprinkler Discharge (gpm) 14.9032.2012.07256.000.06717.02 Sub Totals For Non-Group256.000.06717.02 24.9032.2012.56256.000.06817.37 Sub Totals For Non-Group256.000.06817.37 44.9032.2013.48256.000.07017.99 Sub Totals For Non-Group256.000.07017.99 54.9032.2014.03256.000.07218.35 Sub Totals For Non-Group256.000.07218.35 Totals For All Groups1024.000.06970.74 C:\Users\Bojar\Documents\Elite Software\Fire 6 Projects\Graham..fiwThursday, July 26, 2012, 7:09 PM FIRE - Fire Sprinkler Hydraulics Calculation ProgramElite Software Development, Inc. A & A Fire Protection Graham Residence Glenwood Springs, CO 81611 Page 6 Fire Sprinkler Output Summary Hydraulically Most Demanding Sprinkler Node HMD Sprinkler Node Number:1 HMD Actual Residual Pressure:12.07psi HMD Actual GPM:17.02gpm Sprinkler Summary Sprinkler System Type:Wet Specified Area Of Application:943.00ft² Minimum Desired Density:0.067gpm/ft² Application Average Density:0.075gpm/ft² Application Average Area Per Sprinkler:235.75ft² Sprinkler Flow:70.74gpm Average Sprinkler Flow:17.68gpm Flow Velocity And Imbalance Summary Maximum Flow Velocity ( In Pipe 3 - 6 )14.87ft/sec Maximum Velocity Pressure ( In Pipe 3 - 6 )1.49psi Allowable Maximum Nodal Pressure Imbalance:0.0000psi Actual Maximum Nodal Pressure Imbalance:0.0000psi Actual Average Nodal Pressure Imbalance:0.0000psi Actual Maximum Nodal Flow Imbalance:0.0000gpm Actual Average Nodal Flow Imbalance:0.0000gpm Overall Network Summary Number Of Unique Pipe Sections:15 Number Of Flowing Sprinklers:4 Pipe System Water Volume:22.11gal Sprinkler Flow:70.74gpm Non-Sprinkler Flow:0.00gpm Minimum Required Residual Pressure At System Inflow Node:58.89psi Demand Flow At System Inflow Node:70.74gpm C:\Users\Bojar\Documents\Elite Software\Fire 6 Projects\Graham..fiwThursday, July 26, 2012, 7:09 PM FIRE - Fire Sprinkler Hydraulics Calculation ProgramElite Software Development, Inc. A & A Fire Protection Graham Residence Glenwood Springs, CO 81611 Page 7 Fire Sprinkler Output Data Hydraulic Supply/Demand Graph Pr e s s u r e p s i Flowrate(x100) gpm 130 100 22 0 20 40 60 80 100 120 140 160 180 200 1 2 3 4 5 6 7 8 9 10 Supply Curve Data Static Pressure: 130 psi Test Residual Pressure: 100 psi Test Flow Rate: 500 gpm Demand Curve Data Calculated Residual Pressure: 58.89 psi Calculated Flow Rate: 70.74 gpm Excess Available Residual Pressure At Calculated Flow: 70.31 psi Pressure Required For First Sprinkler Downstream From Inflow Node To Flow: 28.94 psi C:\Users\Bojar\Documents\Elite Software\Fire 6 Projects\Graham..fiwThursday, July 26, 2012, 7:09 PM