Loading...
HomeMy WebLinkAboutB12-0351 04-08-2014 Inspection Request Reporting Page 4 4:05 pm Vail, CO - City Of Requested Inspect Date: Wednesday,April 09 2014 Site Address: 641 W LIONSHEAD CR VAIL Montaneros unit 406 A/P/D Information Activity B12-0351 Type: COMBO Sub Type: AMF Status: ISSUED Const Type Occupancy: Use: Insp Area: Owner HORGAN,NANCY E.&JOHN A. -JT Contractor: AM CARPENTRY Phone: 719-486-2835 Description: NORTH FACING WINDOW REPLACEMENTS BROWN FRAME TO MATCH EXISTING Requested Inspection(s) Item. 90 BLDG-Final Requested Time: 02:00 PM Requestor AM CARPENTRY Phone: 719-486-2835 Comments follow u Assigned To SGREMWER Entered By: JMONDRAGON K Action Time Exp: Inspection History Item: 542 PLAN-FINAL Item: 90 BLDG-Final I REPT131 Run Id: 14761 TOWN OF VA Project Street Address: (Number) (Street) Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970 -479 -2128 www.vaiigov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) (Suite #) Building /Complex Name: 1'nC 4� i-74 AJ a Zd -5 41 Contractor Information Business Name: / /I7 Project #: PRJ Q - ( 31C1 0 DRB #: -b F, A Q e�0� Building Permit #: �ra - Lot #: Block # Subdivision: Business Address: A J / a] - 7 44. 0 r e t 7 Work Class: New 0 Addition () Alteration (3 city LeApylLL E State: 0 Zip: ��'f G / Type of Buildin Contact Name: 4 A N I � �! a �� A Single - Family Commercial G Contact Phone: 9 %11 - 4 Contact E -Mail: /4A) e D A/YJ, a o• ti e Work Type: Duplex G Multi - Family (©j Other 0 Interior O Exterior O Both O I hereby acknowledge that I have read this application, filled out Valuation of in full the information required, completed an accurate plot plan, Work Included Plans Included Work and state that all the information as required is correct. I agree to Electrical OYes �No Oyes $&No comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to Mechanical (OYes No OYesiVo the town's zoning and subdivision codes, design review ap- proved, International Building and Residential Codes and other Plumbing OYes No tOYes .&o ordinances of the Town applicable thereto. ^ _ O 1-)AI Building Wes No es O No X sLL✓ Value of all work being performed: $ i0 1 - S Owner /Owner's Representativ igna (Requir (value based on IBC Section 109.3 & IRC Section 108.3) Electrical Square Footage Applicant Information _ 4)HtiLc/ A/o-, 9dik Detailed Scope and Location of Work: p Applicant Name: 1440# L) 4 /4/-' 1,6 0J /u of ,.;!i civ Applicant Phone: ?741 - 477' - 1A 3 / yU 751Y -5 G kcJ j -e� �� ee n du e- Tv Applicant E -Mail: 1Je- 2 v 4-'4 AAJ b) r' /e4--•, zcz;A�. #Ve-7- U% /ee ie� 241- `D Ad ZI Project Information Owner Name: --/d h AJ 14 • P0 /Z6, / }0J Parcel #: _� / 43 1 6 !c, 'yo `f C),YQ (For Parcel #, contact Eagle County Assessors Office at (970- 328 -8640 or visit www. eag lecou nty. us/patie) For Office Use Only: Fee Paid: Received From: Cash Check # CC: Visa / MC Last 4 CC # exp date: Auth # (use additional sheet if necessary) Date Received: AUG 06 2U, 1.35P TOWN OF VAIL State of Colorado Asbestos Testing & Abatement Requirements Asbestos testing and abatement protects workers, homeowners, neighbors and emergency services responders from ex- posure to harmful asbestos. It is your responsibility to be in compliance with the State. Please contact the State directly for their requirements at the contact info listed below. When is asbestos testing,rgguired7 ANY building projects disturbing more than these threshold levels of building materials require asbestos testing: One- and Two - Family Dwellings: 32 square feet All Others (commercial spaces, hotel rooms, etc): 160 square feet Definition of a single - family dwelling: any dwelling unit that is used primarily for a single family, including multi- family /condominium units, and fractional fee units. Asbestos testing results must be provided with your application for a building permit. Tests which identify POSITIVE results at more than 1% require abatement by a State - certified abatement contractor. The air clearance letter or form must be submitted to the Town of Vail before the building permit will be issued. Project Checklist My project falls into the category checked below: Will not disturb more than the threshold limits identified above. Tested negative, or at 1% or below (1 copies of test results included) Tested positive at more than 1 %, requires abatement (1 copies of test results included) Tips & Facts: • Even recent construction projects may include asbestos - containing materials, so buildings of aM age require testing. • The "1989 Ban" on asbestos - containing materials is commonly misunderstood. "In fact, in 1991 the U.S. Fifth Circuit Court of Appeals vacated much of the so- called "Asbestos Ban and Phaseout" rule and remanded it to the EPA. Thus, much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce of many asbestos - containing product categories was set aside and did not take effect." - CDPHE Asbestos test results should be submitted to: Town of Vail, Community Development, 75 S Frontage Rd, Vail, CO, 81657. Town of Vail Contact: Fire Prevention Bureau Vail Fire Department 75 S Frontage Rd Fire—inspectors@vailgov.com 970 - 479 -2252 www.vailciov.com State of Colorado Contact: Colorado Department of Public Health and Environment Asbestos Compliance Assistance Group 303 - 692 -3158 asbestos @state.co.us www.cdphe.state.co.us Builder Copy -Ship To I?x ! ura) v 4 0 Quote # TBD Montaneros #406 Eagle •.w W I N O O W t O D O R S an AndcncnC'A,mpany Quote TBD Job Tag Company AM Carpentry 231 W. 7th Leadville 9709 - 471 -8103 CO 80461 FAX 719 - 386 -2830 4/20/2012 FAX Bid By Bill Coughlin 303 - 903 -5194 Job Site i Montaneros #406 Lionshead Circle Vail CO 81658 JobPhone Line Item Number um oty Base Price Extended Price Quote # 100 CSLDS2 EA 2 $649.03 $1,298.06 TBD CLAD SLIDE -BY WINDOWS 1 WIDE UNIT, 4 9/16" Wall, Pine, w /Nailfin, NO BRICKMOLD, Frame Bourbon 2604 (152), Sash Bourbon 2604 (152), Primed (E), Colonial Glass Stop, 1 SLIDER, CSLD -02, 4', 11 ", 1/2 ", 4', 7 ", 1/2 ", XO, EQUAL, BEIGE, 2 LOCKS, ONE PULL, BRONZE, Anneal, H /A, Anneal, H /A, L =Low -E (272), R =Low -E (272), DP POS 30, DP NEG 30,1/2 SCREEN, BOURBON FIBER MESH, Rough Opening: 60" X 4'8" Main level Bedrooms S . '�e_ UV�ep.J•J�.�. �e�o, �,cS2.. � v� w`c:�l. we��,�- c�v�� 04._ c cv� U� �1,1�' -ail. -� �rev� u..e_ �� �.�wt�{ 1►..�.�..e_ -� (,-�e. °tr Vul -e- ate- _�t ro c."2QC4, Lkjr\-- Page 1 of 2 rA,r, Quote # TBD Montaneros #406 24�- �, C eh b D 4 Line Item Number UM Qty Base Price Extended Price Quote # 200 CCMTS EA 1 $890.21 $890.21 TBD CLAD CASEMENTS 2 WIDE UNIT, 4 9/16" Wall, Step Jamb, All Sides, Pine, PineJamb, PineMull, STD LGTH, w /Nailfin, NO BRICKMOLD, Frame Bourbon 2604 (152), Sash Bourbon 2604 (152), Primed (E), Colonial Glass Stop, Zero Vert Mull, Zero Horz Mull, �n Axiom 11 Casement, 2', 5 ", 0, 3', 5 ", 0, LEFT HAND, BRONZE, WHITE ARLOC BULB WEATHERSTIP, FOLDING W /COVER, STAINLESS STEEL, 2 LOCKING POINTS, HI- PERFOMANCE KEEPER, Anneal, H /A, Insulated Glass, Low -E (272), DP POS 30, DP NEG 30, BRONZE FIBER MESH SCREEN, Casement, 2', 5 ", 0, 3', 5 ", 0, STATIONARY, 1 PC STAT STOPS ALL SIDES, Anneal, H /A, Insulated Glass, Low -E (272), DP POS 30, DP NEG 30 UP Bedroom Disclaimer Rough Opening: 4' 10 1/2" X 3' 5 1/2" Selling Price $2,188.27 Labor $0.00 Freight $0.00 Sales Tax $63.46 Total Quote $2,251.73 Bd Page 2 of 2 Technical Product Performance Data Summary Customer Information: GREGORY DOOR & WINDOW COMPANY PO BOX 290 vnIw wllll r%NNucu ucraura aJI-ra�.wra. 2006 IECC Table 102.1.3(1) Operable (including sliding and swinging glass doors) Fixed Qty Line Position Unit Type 868696 Unit Unit B,RRECKENRID CO 80424 Height Unit Sqft Total Sqft 59.5 B 45.8646 29 Job Name: ontaneros Quote: 8.2569 29 41 8.2569 46 Rated Units: Totals: 62.3784 Qty Line Position Unit Type 2 100 1 CLAD SLIDE -BY WINDOWS 1 200 1 CLAD CASEMENTS 1 200 2 CLAD CASEMENTS vnIw wllll r%NNucu ucraura aJI-ra�.wra. 2006 IECC Table 102.1.3(1) Operable (including sliding and swinging glass doors) Fixed Qty Line Position Unit Type 868696 Unit Unit Width Height Unit Sqft Total Sqft 59.5 55.5 22.9323 45.8646 29 41 8.2569 8.2569 29 41 8.2569 8.2569 14.218 Totals: 62.3784 Single Double Glazed Glazed 0.95 0.55 0.95 0.55 Unit Unit Width Height Unit Sqft Total Sqft Totals: Eagle � WINDOWS DOORS an AnderscnCc,mpany Weighted Contribution Performance U -Value SHGC VLT to Entire Job Class Weighted Average Job Total With Applied Default U- Factors on Non -Rated Units: 62.3785 19.6676 Percent of Job Non - Rated: 0 % Weighted Average: 0.3153 Quote is valid for 30 days from date of issuance. Page 1 of 1 Weighted Performance U -Value SHGC VLT Contribution Class to Entire Job 0.31 0.29 0.48 14.218 0.33 0.29 0.49 2.725 0.33 0.29 0.49 2.725 19.6676 Weighted Average 0.3153 Weighted Contribution Performance U -Value SHGC VLT to Entire Job Class Weighted Average Job Total With Applied Default U- Factors on Non -Rated Units: 62.3785 19.6676 Percent of Job Non - Rated: 0 % Weighted Average: 0.3153 Quote is valid for 30 days from date of issuance. Page 1 of 1