Loading...
HomeMy WebLinkAboutB12-0355 ComCheck COMcheck Software Version 3.9.1 Interior Lighting and Power Compliance Certificate 90.1 (2007) Standard Section 1: Project Information Project Type: New Construction Project Title : Gore Creek Tenant Renovation Construction Site: Owner/Agent: Designer/Contractor: 193 East Gore Creek Drive Jeff Mullikin Vail,CO 81657 Architectural Engineering Design Group 1900 Wazee Street,Suite#350 Denver,CO 80202 303.296.3034 Section 2: Interior Lighting and Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts ��tz� watts i�tz �e X c� Main Dining Area(Common Space Types:Dining Area-Family Restaurant) 1614 2.1 3389 Allowance:Decorative Appearance/Fix. ID:C 360(a) 1 360(b) Allowance:Decorative Appearance/Fix. ID: E 400(a) 1 150(b) Allowance:Decorative Appearance/Fix. ID:J 450(e) 1 450(b) Allowance:Decorative Appearance/Fix. ID: L 131(a) 1 131(b) Bar Dining Area(Common Space Types:Dining Area-Bar Lounge/Leisure) 180 1.4 252 Kitchen(Common Space Types:Food Preparation) 1172 1.2 1406 Restrooms(Common Space Types:Restrooms) 580 0.9 522 Electrical Room(Common Space Types:Electrical/Mechanical) 74 1.5 111 Bar Storage Area(Common Space Types:Active Storage) 195 0.8 156 Total Allowed Watts= 6928 (a)Area claimed must not exceed the illuminated area permitted for this allowance type. (b) Allowance is(B x C)or the actual wattage of the fixtures given in Section 2,whichever is Iess. (e) Additional controls/switching allowances are based on number of fixtures or wattage controlled, not floor area of allowance. Section 3: Interior Lighting Fixture Schedule A B C D E Fixture ID: Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Main Dining Area(Common Space Types:Dining Area-Family Restaurant 1614 sq.ft.) Halogen 1:A: PINSPOT RECESSED CAN/Halogen MR-16 50W 1 20 50 1000 Linear Fluorescent 1: B:2X2 RECESSED TROFFER/24"T8 17W/Electronic 3 7 54 378 Linear Fluorescent 2:C: LINEAR WALL WASHER/46"T5 28W/Electronic 2 6 66 396 Halogen 2:D: PROJECTOR LIGHT/Halogen MR-16 50W 1 27 50 1350 Incandescent 1:E: LED TAPE LIGHT(3W/LF)/Other 1 50 3 150 Compact Fluorescent 1: F: KITCHEN RECESSED DOWNLIGHT/Triple 4-pin 42W/ 1 23 45 1035 Electronic Halogen 3:H: RECESSED DOWNLIGHT DINING RM/Halogen MR-16 50W 1 16 50 800 Halogen 4:J:SLOTTED WALL WASHER/Halogen MR-16 50W 1 24 50 1200 Linear Fluorescent 3: K: INGRADE UPLIGHT WALL WASHER/22"T5 HO 24W/ 1 5 32 Exempt Electronic Exemption:Retail Display Window Halogen 5:L:RECESSED DOWNLIGHT DEC/Halogen MR-16 50W 1 9 50 450 Linear Fluorescent 4: M:VAPOR TIGHT CEILING SURFACE/48"T8 32W/Electronic 2 3 65 Exempt Project Title: Gore Creek Tenant Renovation Report date: 08/06/12 Data filename:J:\2280.00-Gore Creek TI\Ltg Calcs\228000LCO2-Space x Space ASHRAE90_1.cck Page 1 of Exemption:Lighting in Refrigerator/Freezer Cases Linear Fluorescent 5: N:STORAGE STRIP LIGHTING/48"T8 32W/Electronic 2 2 65 130 Bar Dining Area(Common Space Types:Dining Area-Bar Lounge/Leisure 180 sq.ft.) Kitchen(Common Space Types:Food Preparation 1172 sq.ft.) Restrooms(Common Space Types:Restrooms 580 sq.ft.) Electrical Room(Common Space Types:Electrical/Mechanical 74 sq.ft.) Bar Storage Area(Common Space Types:Active Storage 195 sq.ft.) Total Proposed Watts= 6889 Section 4: Requirements Checklist Lighting Wattage: 0 1. Total proposed watts must be less than or equal to total allowed watts. Allowed Watts Proposed Watts Complies 6928 6889 YES 0 2. Exit signs 5 Watts or less per sign. Controls, Switching, and Wiring: 0 3. Independent manual or occupancy sensing controls for each space(remote switch with indicator allowed for safety or security). � 4. Occupant sensing control in class rooms,conference/meeting rooms,and employee lunch and break rooms. Exceptions: � Spaces with multi-scene control;shop classrooms,laboratory classrooms,and preschool through 12th grade classrooms. � 5. Automatic shutoff control for lighting in>5000 sq.ft buildings by time-of-day device,occupant sensor,or other automatic control. Exceptions: � 24 hour operation lighting;patient care areas;where auto shutoff would endanger safety or security. � 6. Master switch at entry to hotel/motel guest room. 0 7. Separate control device for display/accent lighting,case lighting,task lighting,nonvisual lighting,lighting for sale,and demonstration lighting. � 8. Tandem wired one-lamp and three-lamp ballasted luminaires(No single-lamp ballasts). Exceptions: � Electronic high-frequency ballasts. � Luminaires not on same switch. � Recessed luminaires 10 ft.apart or surface/pendant not continuous. � Luminaires on emergency circuits. Voltage Drop: � 9. Feeder conductors have been designed for a maximum voltage drop of 2 percent. � 10.Branch circuit conductors have been designed for a maximum voltage drop of 3 percent. r- . •- ..- Section 5: Compliance Statement Compliance Statement.� The proposed lighting design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application.The proposed lighting system has been designed to meet the 90.1 (2007)Standard requirements in COMcheck Version 3.9.1 and to comply with the mandatory requirements in the Requirements Checklist. Jeff Mullikin, Principal 8/6/2012 Name-Title Signature Date Section 5: Post Construction Compliance Statement Record Drawings and Operating and Maintenance Manuals: � 1. Construction documents with record drawings and operating and maintenance manuals provided to the owner. Project Title: Gore Creek Tenant Renovation Report date: 08/06/12 Data filename:J:\2280.00-Gore Creek TI\Ltg Calcs\228000LCO2-Space x Space ASHRAE90_1.cck Page 2 of Lighting Designer or Contractor Name Signature Date Project Title: Gore Creek Tenant Renovation Report date: 08/06/12 Data filename:J:\2280.00-Gore Creek TI\Ltg Calcs\228000LCO2-Space x Space ASHRAE90_1.cck Page 3 of