Loading...
HomeMy WebLinkAboutB12-0367 g. 3 � _ 1 (�, ' 3 � . • 07-17-2015 Inspection Request Re orting Page 1 4•06 pm Vail, CO - �itv O� Requested Inspect Date: Monday July 20 2015 Site Address: 4936 JU�VIPER L�V VAIL A/P/D Information Activity: 612-0367 Type: COMBO Sub Type: ASFR Status: ISSUED Const Type: Occupancy: Use: R-3 insp Area: Owner: CUMMINGS,GREGORY&JANICE Contractor: CUMMINGS,GREG Phone: 970-376-3911 Contractor: G&J CONSTRUCTION, INC. Phone: 970-476-3254 Description: NEW SINGLE FAMILY RESIDENCE Reauested Inspection(s) Item: 534 PLAN-FINAL C/O Requested Time: 08:00 AM Requestor: Phone: Comments: 376-3911 Assigned To: GRU Entered B : MHAEBERLE K Action: T' ' � �Q ` \-- ✓ L. �L/��� J . Item: 535 DIA-30 DAY REMINDER Requested Time: 08:15 AM Requestor: Phone: Comments: 376-3911 Assigned To: GRUTHER Entered By: MHAEBERLE K Action: Time Exp: .� Item: 539 C/O � Requested Time: 08:00 AM Requestor: Phone: Comments: 376-3911 ��� �"� P ti-'D Assigned To: JMOND GON Entered By: HAEBERLE K Action: �-' Time Exp: �_ �. — `v'�7C�1�y�T\�{--......_. - -�- Item: 90 BLDG-Final Requested Time: 10:30 AM Requestor: Phone: Comments: 376-3911 Assigned To: SGREMMER y �`� vcf � Entered By: MHAEBERLE K Action: Time Ex�p: Comment: TCO MISSING COPYOF-FII�AL SI REPORT AND BALANCE DUE FOR REVISION. ALL BUILDING ELEMENTS ARE COMPLETED / �' /" � , � '�� � � � �� Inspection Historv Item: 10 BLDG-FOOTING '*Approved" 09/20/12 Inspector: mdenney Action: AP APPROVED Comment: Item: 20 BLDG-Foundation/Steel *'Approved" 10/02/12 Inspector: sgremmer Action: AP APPROVED Comment: ��� Item: 110 ELEC-Service "'Approved" 09/26/12 Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: Temp 08/20/14 Inspector: sgremmer Action: AP APPROVED Comment: Item: 120 ELEC-Rough "Approved" 04/24/14 Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: sofiit cans only REPT131 Run Id: 14641 , � Department of Community Development �' 75 South Frontage Road TOWI� OF VAt�.�`�� va�i, co a�ss7 Tel: 970-479-2128 www.vailgov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) �Project Street Address: P� b G� � � Project#: — � �O �'9� J u�,�oP.� < <:�►ti � DRB#: ����2.D C�D '� (Number) (Street) (Suite#) Building/Complex Name: (v�,lr, Building Permit#: � � �^ (� ��n 1 Contractor Information � ��� Lot#: Block# Subdivision: 6 __ _.. ..._ - ---.._._.. ____. __._.-- Business Name: L°q Inw�,►•�,n�A S__ _ � � /� � �q n , �Work Class: New(✓j -� "�it�un t ; alteration( ) � Business Address: �j/,3�,�j /v/����70�P (l/. � __ __ � City�Q�� State: C Q Zip: g� ,� {Type of Building: Single-Family(V) Duplex( ) Multi-Family( ) Contact Name: 7"l�� um�,+�t�.v�' S � Commercial( ) Other( ) Contact Phone: 9�� �37�-�/� � � Work Type: Interior( ) Exterior( ) Both(� Contact E-Mail:TG�,Q,/G��9� �O�nc�5': ��� _/ '� Valuation of X G� Work Included Plans Included Work Owner/Own sen ative Si nature Re uired � 9 � q ) �Electrical ( )Yes ( )No ( �'es ( )No ��� Applicant Information l, �Mechanical (✓�Yes ( )No (�es ( )No �� /� � ApplicantName: .��)/'��, f.(�u�IriiVdS �Plumbing (✓SYes ( )No ('�Yes ( )No ����I � Applicant Phone: �7a'"37�`,3�'7// Building ( �Yes ( )No ( �Yes ( )No l���l� Applicant E-Mail: ���r,o`����•�.C�3 t,N2 7 Value of all work being performed: $ � �T _ —_��value based on IBC Section 109.3 8 IRC Section 108.3� Project Information �Electrical Square Footage � Owner Name: �P�«#� �b r--1 31 - o v ! For Parc #,contact Eagle County Assessors O�ce at(970-328-8640 or visit � .e ecounty.us/patie) �• _.._.. :�.�—_-._ ._�;��w..�_�-x�_.y.�.,,-� �,:_ __��;.�-} _ _..._r....._ Detailed Scope and Location of Work: � � � L✓ � � ��QGco tT �C�/AJ ��P✓P/ f7—ier,ce�.o Asv� �/�✓�r� .�s'r�bu,w .�'1 L�✓p� Q/La.r[�° I i(use additional sheet if necessary) --- — _— _ — _— —� For Office Use Only: Date Received: Fee Paid: � � � I t� � � � ' Received From: Cash Check # AUG I � ZQ�Z CC: Visa / MC Last 4 CC # exp date: Auth # TOWN O� ��#IL O 1-lan-11 TOWN OF VAIL � 75 South Frontage Road West Community Development Department Vail, Colorado 81I657 970.479.2138 vailgov.com ��, 970.479.2452 fax I 01/08/13 Dear Mr. Cummings. The purpose f this letter is to clarify the square footage allowance and use as determined ir�the Town of Vail Building Department plan review of your project located at 49�6 Juniper Lane, in Vail Colorado. The building permit is listed as 612-0367. The plan review lists the project as a new single family residence with a total square footage as 11918. The square footage is broken down as follows: Garage ( basement level) 4375 square feet Garage ( middle level) 825 square feet Bath room located on basement level 26 square feet First level (living) 2544 square feet Second level (living) 4148 square feet Both garage areas will conform to 2009 IRC section R309.1 (garages) The required fire ratings shall conform to the adopted building code. The building will be fully sprinklered. Any changes to the building, whether interior or exterior will require approvals from the Town of Vail Building and Planning Departments thru the development process. Approval must be obtained prior to commencing any changes. Thank you ; Sincere ' F ragon Jr own of Community Development Department Vail,Colorado 81657 970-479-2143 RadiantWorks Professional Mechanical Summary Report 7/30/2012 Project Information Contact Information Project Assumptions Project Number Designed By G PECK Outdoor Temp -21 °F Project Quote Company Name GT SANDERS Elevation 9300 ft Project Name CUMMINGS RES Phone Number Wind Speed 10 mph Designed For Job Type Residential VAIL , CO (Colorado) Nt i �t Pump Specs Zone Name Flow Head Delta T Supply Fluid Temp Zone 1 1.2 0.5 20 140 Zone 2 1.2 0.8 20 140 Zone 3 1.7 0.7 20 140 Zone 4 2.2 0.6 20 140 Zone 5 2.1 1.8 20 140 Zone 6 1.2 0.5 20 140 Zone 7 0.6 0.7 20 140 Zone 8 0.6 0.2 20 140 Zone 9 0.7 0.9 20 140 Zone 10 0.2 0.1 20 140 Zone 11 1.8 1.5 20 140 Zone 12 0.9 0.7 20 140 Zone 13 0.7 0.9 20 140 Zone 14 1.7 2.2 20 140 Zone 15 1 0.9 20 140 Zone 16 3.7 2.5 20 140 Heated Area Descriptions Application Construction Heated Area Product Totals Zone 1 o Room List (GARAGE NW WING) Radiant Heating Slab 802 ft2 (5) 200' Lengths of 112" RadiantPEX+ Zone 2 - Room List (GARAGE S.W. WING) Radiant Heating Slab 720 ft2 (4) 200' Lengths of 1/2" RadiantPEX+ Zone 3 - Room List (GARAGE CENTRAL) Radiant Heating Slab 957 ft2 (6) 200' Lengths of 1/2" RadiantPEX+ Zone 4 - Room List (GARAGE EAST WING) Radiant Heating Slab 1445 ft2 (8) 200' Lengths of 1/2" RadiantPEX+ Zone 5 - Room List (UPPER GARAGE) Radiant Heating Slab 738 ft2 (4) 200' Lengths of 1/2" RadiantPEX+ Zone 6 - Room List (FAMILY ROOM) Radiant Heating ThinSlab 846 ft2 (5) 200' Lengths of 1/2" RadiantPEX+ CUMMINGS RES.rad Copyright(c) Watts Radiant 2008 Page 1 of 4 RadiantWorks Professional Mechanical Summary Report 7/30/2012 Zone 7 <> Room List (BEDROOM/ CLOSET #1, BATH #1) Radiant Heating ThinSlab 368 ft2 (2) 200' Lengths of 1/2" RadiantPEX+ Zone 8 <> Room List (BEDROOM/ CLOSET #2, CLOSET #2) Radiant Heating ThinSlab 385 ft2 (3) 200' Lengths of 1/2" RadiantPEX+ Zone 9 <> Room List (BEDROOM/ CLOSET #3, BATH #3) Radiant Heating ThinSlab 285 ft2 (2) 200' Lengths of 1/2" RadiantPEX+ Zone 10 <> Room List (HALL/ POWDER/ LAUNDRY) Radiant Heating ThinSlab 237 ft2 (2) 200' Lengths of 1/2" RadiantPEX+ Zone l l <> Room List (ENTRY FOYER/ STAIRS/ POWDER RM, MUDROOM, OFFICE, MASTER LAUNDRY) Radiant Heating ThinSlab 691 ft2 (4) 200' Lengths of 1/2" RadiantPEX+ Zone 12 <> Room List (MASTER BEDRM / CLOSET) Radiant Heating ThinSlab 445 ft2 (3) 200' Lengths of 1/2" RadiantPEX+ Zone 13 <> Room List (MASTER BATH) Radiant Heating ThinSlab 265 ft2 (2) 200' Lengths of 1/2" RadiantPEX+ Zone 14 <> Room List (WORKOUT ROOM / BATH) Radiant Heating ThinSlab 564 ft2 (3) 200' Lengths of 1/2" RadiantPEX+ Zone 15 <> Room List (KITCHEN / PANTRY) Radiant Heating ThinSlab 475 ft2 (3) 200' Lengths of 1/2" RadiantPEX+ Zone 16 <> Room List (BILLIARD RM, LIVING ROOM, DINING ROOM) Radiant Heating ThinSlab 1042 ft2 (6) 200' Lengths of 1/2" RadiantPEX+ Heating Load Summary Tube Back/Edge Total Total Supp. Spacing Intensity Losses Required Provided Needed Zone 8792 63831 GARAGE NW WING 12 10.96 3.79 8792 63831 Zone 2 9568 57357 GARAGE S.W. WING 12 13.29 3.82 9568 57357 Zone 3 13715 76051 GARAGE CENTRAL 12 14.33 3.82 13715 76051 Zone 4 16757 114408 GARAGE EAST WING 12 11.6 3.80 16757 114408 Zone 5 16751 58539 UPPER GARAGE 12 22.7 5.47 16751 58539 CUiv MiNGS RES.rad Copyright(c) Watts Radiant 2008 Page 2 of 4 RadiantWorks Professional Mechanical Summary Report 7/30/2012 Zone 6 Total Flow: 21.7 GPM 11034 34720 FAMILY ROOM 12 13.04 1.31 11034 34720 Zone 7 5599 16089 BEDROOM / CLOSET #1 12 17.66 1.40 5086 10521 BATH #1 12 6.41 1.39 513 5568 Zone 8 5906 18566 BEDROOM / CLOSET #2 12 18.18 1.43 5310 10667 CLOSET #2 12 6.41 1.62 596 7899 Zone 9 6553 13552 BEDROOM / CLOSET #3 12 22.52 1.64 4548 7388 BATH #3 12 24.16 1.58 2005 6164 Zone 10 1519 16334 HALL / POWDER / LAUNDRY 12 6.41 1.42 1519 16334 Zone 11 16984 52104 ENTRY FOYER / STAIRS / POWDER RM 12 26.35 2.13 11885 37635 MUDROOM 12 20.24 1.52 1983 7269 OFFICE 12 24.44 1.71 2126 3358 MASTER LAUNDRY 12 18 1.53 990 3842 Zone12 8314 16237 MASTER BEDRM / CLOSET 12 18.68 1.44 8314 16237 Zone13 6571 19500 MASTER BATH 12 24.8 1.57 6571 19500 Zone 14 16086 22389 WORKOUT ROOM/ BATH 12 28.52 1.83 16086 22389 Zone 15 9492 34790 KITCHEN / PANTRY 12 19.98 1.49 9492 34790 Zone16 36924 41433 BILLIARD RM 12 29.13 1.83 9875 13482 LIVING ROOM 12 47.11 2.61 14603 12331 YES DINING ROOM 12 31.67 1.93 12446 15620 Project Summary Total Flow: 21.7 GPM Total System Head: 2.5 ft Boiler Load: 216589 BTU /h Total System Volume: 119 Gallons Total Heated Area: 10265 ftZ CUMMINGS RES.rad Copyright(c) Watts Radiant 2008 Page 3 of 4 .IE ATING DESIGN INFORMATION SHEET � � SEN DING BRANCH: SILVERTHORNE � CONTRACTOR: f ACCOUNT #. PHONE #: PHONE M �l - CONTACT: JCELL JOB NAME: J C4 o y��f L,-q 11 'e - DATE: 2-0( 2 JOB SITE ELEVATION: C/ -?,/) U BOILER PREFERENCE: BUDERUS BURNHAM LAARS TRIANGLE TUBE TRIANGLE COMBO WRITE IN ANY UNLISTED. BOILER BELOW ATMOSPHERIC G124, G234, G334 ATMOSPHERIC 2B, 8 SERIES ATMOSPHERIC JV, HK SEALED COMB PG SERIES CONDENSING EXCELLENCE 110 SEALED COMB GA124, GA244 SEALED COMB RV OR SP POWER VENT JVH CONDENSING PRESTIGE CONDENSING GB142 SEALED COMB PNCH FUEL TYPE: NATURAL ELECTRIC H:!;AT DISTRIBUTION: RADIANT \ BASEBOARD FAN COILS RADIATORS RADIAiaT FRAMED FLOORS ARE: �� LT CONCRETE GYPCRE?E S' 2N ON GRADE S'lAPI.ED UP WATER HEATER TYPE: INDIRECT \ ELECTRIC BOILERiSTORAGE TANK IF INDIRECT .PREFERENCE: TRIANGLE TUBE SUPERSTOR BUDERUS BRADFORD WHITE TYPE OF GARAGE HEAT: RADIANT BASEBOARD UNIT HEATER NO HEAT LIST ANY S(N�OWMELT AREAS: LIST ANY COMMENTS OR SPECIAL INSTRUCTION : JJ d W41 r k] 1/G !`1 2. 2. iG� /tai G f4 3. 3. 7 4G / pt 5. 5. 6. 6. 7. 7. PLEASE PROVIDE DETAILED DESCRIPTION OF HEATING REQUIREM.EN'I'S FOR REMODELS AND ADDITIONS TO EXISTING HOMES. 5////2 Cagl e/SummLt Uecf n Lc Co. Lnc. I Lc3578 pa./ o� / Randy % Lngl e col o maaf en 4395 C.Lect n Lcal Load Cal cul of Lon 4936 Yuntpen .Lot 6 aLh. / BLaAoan 5fh. addLtLon VaLl CoLonado 7981 aq. ' @ 3va. pen / -hot tub 24ov / -wall oven 2- laundng cLA. 2- diahwaahen @ 1200ea. 3- appl Lance CLA @ 1500 ea. /- ateam ahowen boLlen and pumper 300' anow melt @ 6va. pen ' /- centnaL vac, /- elevators total va. /af /0,000 va. @ 100% bal. 64, 883 va. @40% total demand 35,953 va. 35,953 va. clLvLded by 240v =149 amp houae meteALng to be 325 amp cont. /0 w/ 2 panels 23,943 va. 9, 600 va 8, 000 va. 3, 000 va. 2, 400 va. 4 500 va. 9, 600 va. 000 va. 800 va. /, 920 va. 9, /20 va ---------- - - - - -- 74,883 va. CNJ( Energy Code: Location: Construction Type: Building Orientation: Glazing Area Percentage Heating Degree Days: Climate Zone: Construction Site: Juniper Lane Vail, CO REScheck Software Version 4.4.3 Compliance Certificate 2009 IECC Vail, Colorado Single Family Bldg. orientation unspecified 19% 9248 6 Owner /Agent: Compliance: Compliance: 13.0% Better Than Code Maximum UA: 965 Your UA: 840 The % Better or Worse Than Code index reflects how close to compliance the house is based on code trade -off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Ceiling 1: Cathedral Ceiling Ceiling 2: Flat Ceiling or Scissor Truss Floor 1: All -Wood Joist/Truss:Over Unconditioned Space Wall 1: Wood Frame, 16" o.c. Orientation: Unspecified Window 2: Wood Frame:Double Pane with Low -E SHGC: 0.00 Orientation: Unspecified Designer /Contractor: 5023 47.0 0.0 111 764 47.0 0.0 20 1600 47.0 0.0 35 6806 23.0 0.0 304 1275 0.290 370 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in REScheck Version 4.4.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. // 2 1 fi Rame - Titlej — ignat Date Project Title: Data filename: C: \Documents and Settings \Owner\My Documents\REScheck \Juniper Lane.rck Report date: 08/09/12 Page 1 of 4 t2TREScheck Software Version 4.4.3 Inspection Checklist Energy Code: 2009 IECC Location: Vail, Colorado Construction Type: Single Family Building Orientation: Bldg. orientation unspecified Glazing Area Percentage: 19% Heating Degree Days: 9248 Climate Zone: 6 Ceilings: ❑ Ceiling 1: Cathedral Ceiling, R-47.0 cavity insulation Comments: ❑ Ceiling 2: Flat Ceiling or Scissor Truss, R-47.0 cavity insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, 16" o.c., R -23.0 cavity insulation Comments: Windows: ❑ Window 2: Wood Frame:Double Pane with Low -E, U- factor: 0.290 For windows without labeled U- factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: Floors: ❑ Floor 1: All -Wood Joist/Truss:Over Unconditioned Space, R-47.0 cavity insulation Comments: Floor insulation is installed in permanent contact with the underside of the subfloor decking. Air Leakage: ❑ Joints (including rim joist junctions), attic access openings, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed with caulk, gasketed, weatherstripped or otherwise sealed with an air barrier material, suitable film or solid material. ❑ Air barrier and sealing exists on common walls between dwelling units, on exterior walls behind tubs /showers, and in openings between window /doorjambs and framing. ❑ Recessed lights in the building thermal envelope are 1) type IC rated and ASTM E283 labeled and 2) sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. ❑ Access doors separating conditioned from unconditioned space are weather - stripped and insulated (without insulation compression or damage) to at least the level of insulation on the surrounding surfaces. Where loose fill insulation exists, a baffle or retainer is installed to maintain insulation application. Wood - burning fireplaces have gasketed doors and outdoor combustion air. Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. Air Sealing and Insulation: ❑ Building envelope air tightness and insulation installation complies by either 1) a post rough -in blower door test result of less than 7 ACH at 50 pascals OR 2) the following items have been satisfied: (a) Air barriers and thermal barrier: Installed on outside of air - permeable insulation and breaks or joints in the air barrier are filled or repaired. (b) Ceiling /attic: Air barrier in any dropped ceiling /soffit is substantially aligned with insulation and any gaps are sealed. (c) Above -grade walls: Insulation is installed in substantial contact and continuous alignment with the building envelope air barrier. (d) Floors: Air barrier is installed at any exposed edge of insulation. Project Title: Report date: 08/09/12 Data filename: C: \Documents and Settings \Owner \My Documents\REScheck\Juniper Lane.rck Page 2 of 4 (e) Plumbing and wiring: Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing, or sprayed /blown insulation extends behind piping and wiring. (f) Corners, headers, narrow framing cavities, and rim joists are insulated. (9) Shower /tub on exterior wall: Insulation exists between showers /tubs and exterior wall. Sunrooms: Ej Sunrooms that are thermally isolated from the building envelope have a maximum fenestration U- factor of 0.50 and the maximum skylight U- factor of 0.75. New windows and doors separating the sunroom from conditioned space meet the building thermal envelope requirements. Materials Identification and Installation: F1 Materials and equipment are installed in accordance with the manufacturer's installation instructions. F-I Materials and equipment are identified so that compliance can be determined. F1 Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. r-i Insulation R- values and glazing U- factors are clearly marked on the building plans or specifications. Duct Insulation: F-1 Supply ducts in attics are insulated to a minimum of R -8. All other ducts in unconditioned spaces or outside the building envelope are insulated to at least R -6. Duct Construction and Testing: I Building framing cavities are not used as supply ducts. F-I All joints and seams of air ducts, air handlers, filter boxes, and building cavities used as return ducts are substantially airtight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Tapes, mastics, and fasteners are rated UL 181A or UL 181B and are labeled according to the duct construction. Metal duct connections with equipment and /or fittings are mechanically fastened. Crimp joints for round metal ducts have a contact lap of at least 1 1/2 inches and are fastened with a minimum of three equally spaced sheet -metal screws. Exceptions: Joint and seams covered with spray polyurethane foam. Where a partially inaccessible duct connection exists, mechanical fasteners can be equally spaced on the exposed portion of the joint so as to prevent a hinge effect. Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). Lj Duct tightness test has been performed and meets one of the following test criteria: (1) Postconstruction leakage to outdoors test: Less than or equal to 8 cfm per 100 ft2 of conditioned floor area. (2) Postconstruction total leakage test (including air handler enclosure): Less than or equal to 12 cfm per 100 U. (3) Rough -in total leakage test with air handler installed: Less than or equal to 6 cfm per 100 ft2 of conditioned floor area. (4) Rough -in total leakage test without air handler installed: Less than or equal to 4 cfm per 100 ft2 of conditioned floor area. Temperature Controls: Where the primary heating system is a forced air - furnace, at least one programmable thermostat is installed to control the primary heating system and has set - points initialized at 70 degree F for the heating cycle and 78 degree F for the cooling cycle. ❑ Heat pumps having supplementary electric- resistance heat have controls that prevent supplemental heat operation when the compressor can meet the heating load. Heating and Cooling Equipment Sizing: Additional requirements for equipment sizing are included by an inspection for compliance with the International Residential Code. For systems serving multiple dwelling units documentation has been submitted demonstrating compliance with 2009 IECC Commercial Building Mechanical and /or Service Water Heating (Sections 503 and 504). Circulating Service Hot Water Systems: J Circulating service hot water pipes are insulated to R -2. 1-1 Circulating service hot water systems include an automatic or accessible manual switch to turn off the circulating pump when the system is not in use. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to R -3. Swimming Pools: Heated swimming pools have an on /off heater switch. Pool heaters operating on natural gas or LPG have an electronic pilot light. Project Title: Report date: 08/09/12 Data filename: C:1Documents and SettingslOwnerlMy Documents\RESchecklJuniper Lane.rck Page 3 of 4 0 Timer switches on pool heaters and pumps are present. Exceptions: Where public health standards require continuous pump operation. Where pumps operate within solar- and /or waste- heat - recovery systems. Heated swimming pools have a cover on or at the water surface. For pools heated over 90 degrees F (32 degrees C) the cover has a minimum insulation value of R -12. Exceptions: Covers are not required when 60% of the heating energy is from site - recovered energy or solar energy source. Lighting Requirements: L7 A minimum of 50 percent of the lamps in permanently installed lighting fixtures can be categorized as one of the following: (a) Compact fluorescent (b) T -8 or smaller diameter linear fluorescent (c) 40 lumens per watt for lamp wattage — 15 (d) 50 lumens per watt for lamp wattage > 15 and — 40 (e) 60 lumens per watt for lamp wattage > 40 Other Requirements: Snow- and ice- melting systems with energy supplied from the service to a building shall include automatic controls capable of shutting off the system when a) the pavement temperature is above 50 degrees F, b) no precipitation is falling, and c) the outdoor temperature is above 40 degrees F (a manual shutoff control is also permitted to satisfy requirement's'). Certificate: F-1 A permanent certificate is provided on or in the electrical distribution panel listing the predominant insulation R- values; window U- factors; type and efficiency of space- conditioning and water heating equipment. The certificate does not cover or obstruct the visibility of the circuit directory label, service disconnect label or other required labels. NOTES TO FIELD: (Building Department Use Only) Project Title: Report date: 08/09/12 Data filename: C:\Documents and Settings \Owner \My Documents\REScheck\Juniper Lane.rck Page 4 of 4 CJ/ 2009 IECC Energy Efficiency Certificate Insulation Rating R-Value Ceiling / Roof 47.00 Wall 23.00 Floor / Foundation 47.00 Ductwork (unconditioned spaces): Window Door 0.29 Heating & Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Comments