07-17-2015 Inspection Request Re orting Page 1
4•06 pm Vail, CO - �itv O�
Requested Inspect Date: Monday July 20 2015
Site Address: 4936 JU�VIPER L�V VAIL
A/P/D Information
Activity: 612-0367 Type: COMBO Sub Type: ASFR Status: ISSUED
Const Type: Occupancy: Use: R-3 insp Area:
Owner: CUMMINGS,GREGORY&JANICE
Contractor: CUMMINGS,GREG Phone: 970-376-3911
Contractor: G&J CONSTRUCTION, INC. Phone: 970-476-3254
Description: NEW SINGLE FAMILY RESIDENCE
Reauested Inspection(s)
Item: 534 PLAN-FINAL C/O Requested Time: 08:00 AM
Requestor: Phone:
Comments: 376-3911
Assigned To: GRU Entered B : MHAEBERLE K
Action: T' ' � �Q ` \--
✓ L. �L/��� J .
Item: 535 DIA-30 DAY REMINDER Requested Time: 08:15 AM
Requestor: Phone:
Comments: 376-3911
Assigned To: GRUTHER Entered By: MHAEBERLE K
Action: Time Exp:
.�
Item: 539 C/O � Requested Time: 08:00 AM
Requestor: Phone:
Comments: 376-3911 ��� �"� P ti-'D
Assigned To: JMOND GON Entered By: HAEBERLE K
Action: �-' Time Exp:
�_ �.
— `v'�7C�1�y�T\�{--......_. -
-�-
Item: 90 BLDG-Final Requested Time: 10:30 AM
Requestor: Phone:
Comments: 376-3911
Assigned To: SGREMMER y �`� vcf � Entered By: MHAEBERLE K
Action: Time Ex�p:
Comment: TCO MISSING COPYOF-FII�AL SI REPORT AND BALANCE DUE FOR REVISION.
ALL BUILDING ELEMENTS ARE COMPLETED
/ �' /"
� , � '�� � �
�
��
Inspection Historv
Item: 10 BLDG-FOOTING '*Approved"
09/20/12 Inspector: mdenney Action: AP APPROVED
Comment:
Item: 20 BLDG-Foundation/Steel *'Approved"
10/02/12 Inspector: sgremmer Action: AP APPROVED
Comment: ���
Item: 110 ELEC-Service "'Approved"
09/26/12 Inspector: sgremmer Action: PI PARTIAL INSPECTION
Comment: Temp
08/20/14 Inspector: sgremmer Action: AP APPROVED
Comment:
Item: 120 ELEC-Rough "Approved"
04/24/14 Inspector: sgremmer Action: PI PARTIAL INSPECTION
Comment: sofiit cans only
REPT131 Run Id: 14641
,
� Department of Community Development
�' 75 South Frontage Road
TOWI� OF VAt�.�`�� va�i, co a�ss7
Tel: 970-479-2128
www.vailgov.com
Development Review Coordinator
BUILDING PERMIT APPLICATION
(Separate applications are required for alarm & sprinkler)
�Project Street Address: P� b G� �
� Project#: — � �O
�'9� J u�,�oP.� < <:�►ti �
DRB#: ����2.D C�D '�
(Number) (Street) (Suite#)
Building/Complex Name: (v�,lr, Building Permit#: � � �^ (� ��n 1
Contractor Information � ��� Lot#: Block# Subdivision:
6 __ _.. ..._ - ---.._._..
____. __._.--
Business Name: L°q Inw�,►•�,n�A S__ _ � � /� �
�q n , �Work Class: New(✓j -� "�it�un t ; alteration( ) �
Business Address: �j/,3�,�j /v/����70�P (l/. � __ __ �
City�Q�� State: C Q Zip: g� ,� {Type of Building:
Single-Family(V) Duplex( ) Multi-Family( )
Contact Name: 7"l�� um�,+�t�.v�' S � Commercial( ) Other( )
Contact Phone: 9�� �37�-�/�
� � Work Type: Interior( ) Exterior( ) Both(�
Contact E-Mail:TG�,Q,/G��9� �O�nc�5': ���
_/
'� Valuation of
X G� Work Included Plans Included Work
Owner/Own sen ative Si nature Re uired �
9 � q ) �Electrical ( )Yes ( )No ( �'es ( )No ���
Applicant Information l, �Mechanical (✓�Yes ( )No (�es ( )No ��
/� �
ApplicantName: .��)/'��, f.(�u�IriiVdS �Plumbing (✓SYes ( )No ('�Yes ( )No ����I �
Applicant Phone: �7a'"37�`,3�'7// Building ( �Yes ( )No ( �Yes ( )No l���l�
Applicant E-Mail: ���r,o`����•�.C�3 t,N2 7 Value of all work being performed: $ � �T
_ —_��value based on IBC Section 109.3 8 IRC Section 108.3�
Project Information �Electrical Square Footage �
Owner Name:
�P�«#� �b r--1 31 - o v !
For Parc #,contact Eagle County Assessors O�ce at(970-328-8640 or visit
� .e ecounty.us/patie)
�• _.._.. :�.�—_-._ ._�;��w..�_�-x�_.y.�.,,-� �,:_ __��;.�-} _ _..._r....._
Detailed Scope and Location of Work: � � � L✓ �
� ��QGco tT �C�/AJ ��P✓P/ f7—ier,ce�.o Asv� �/�✓�r� .�s'r�bu,w .�'1 L�✓p� Q/La.r[�°
I
i(use additional sheet if necessary) --- — _— _ — _— —�
For Office Use Only: Date Received:
Fee Paid: � � � I t� � � � '
Received From:
Cash Check # AUG I � ZQ�Z
CC: Visa / MC Last 4 CC # exp date:
Auth # TOWN O� ��#IL
O 1-lan-11
TOWN OF VAIL �
75 South Frontage Road West Community Development Department
Vail, Colorado 81I657 970.479.2138
vailgov.com ��, 970.479.2452 fax
I
01/08/13
Dear Mr. Cummings.
The purpose f this letter is to clarify the square footage allowance and use as
determined ir�the Town of Vail Building Department plan review of your project
located at 49�6 Juniper Lane, in Vail Colorado.
The building permit is listed as 612-0367.
The plan review lists the project as a new single family residence with a total square
footage as 11918.
The square footage is broken down as follows:
Garage ( basement level) 4375 square feet
Garage ( middle level) 825 square feet
Bath room located on basement level 26 square feet
First level (living) 2544 square feet
Second level (living) 4148 square feet
Both garage areas will conform to 2009 IRC section R309.1 (garages)
The required fire ratings shall conform to the adopted building code.
The building will be fully sprinklered.
Any changes to the building, whether interior or exterior will require approvals from the
Town of Vail Building and Planning Departments thru the development process.
Approval must be obtained prior to commencing any changes.
Thank you ;
Sincere '
F ragon Jr
own of
Community Development Department
Vail,Colorado 81657
970-479-2143
RadiantWorks Professional Mechanical Summary Report 7/30/2012
Project Information Contact Information Project Assumptions
Project Number Designed By G PECK Outdoor Temp -21 °F
Project Quote Company Name GT SANDERS Elevation 9300 ft
Project Name CUMMINGS RES Phone Number Wind Speed 10 mph
Designed For Job Type Residential
VAIL , CO (Colorado)
Nt i �t
Pump Specs
Zone Name
Flow
Head
Delta T
Supply Fluid Temp
Zone 1
1.2
0.5
20
140
Zone 2
1.2
0.8
20
140
Zone 3
1.7
0.7
20
140
Zone 4
2.2
0.6
20
140
Zone 5
2.1
1.8
20
140
Zone 6
1.2
0.5
20
140
Zone 7
0.6
0.7
20
140
Zone 8
0.6
0.2
20
140
Zone 9
0.7
0.9
20
140
Zone 10
0.2
0.1
20
140
Zone 11
1.8
1.5
20
140
Zone 12
0.9
0.7
20
140
Zone 13
0.7
0.9
20
140
Zone 14
1.7
2.2
20
140
Zone 15
1
0.9
20
140
Zone 16
3.7
2.5
20
140
Heated Area Descriptions
Application
Construction
Heated Area
Product Totals
Zone 1 o Room List (GARAGE NW WING)
Radiant Heating
Slab
802 ft2
(5) 200' Lengths of 112"
RadiantPEX+
Zone 2 - Room List (GARAGE S.W. WING)
Radiant Heating
Slab
720 ft2
(4) 200' Lengths of 1/2"
RadiantPEX+
Zone 3 - Room List (GARAGE CENTRAL)
Radiant Heating
Slab
957 ft2
(6) 200' Lengths of 1/2"
RadiantPEX+
Zone 4 - Room List (GARAGE EAST WING)
Radiant Heating
Slab
1445 ft2
(8) 200' Lengths of 1/2"
RadiantPEX+
Zone 5 - Room List (UPPER GARAGE)
Radiant Heating
Slab
738 ft2
(4) 200' Lengths of 1/2"
RadiantPEX+
Zone 6 - Room List (FAMILY ROOM)
Radiant Heating
ThinSlab
846 ft2
(5) 200' Lengths of 1/2"
RadiantPEX+
CUMMINGS RES.rad
Copyright(c) Watts Radiant 2008
Page 1 of 4
RadiantWorks Professional Mechanical Summary Report
7/30/2012
Zone 7 <> Room List (BEDROOM/ CLOSET #1, BATH #1)
Radiant Heating
ThinSlab
368 ft2
(2) 200' Lengths of 1/2"
RadiantPEX+
Zone 8 <> Room List (BEDROOM/ CLOSET #2, CLOSET #2)
Radiant Heating
ThinSlab
385 ft2
(3) 200' Lengths of 1/2"
RadiantPEX+
Zone 9 <> Room List (BEDROOM/ CLOSET #3, BATH #3)
Radiant Heating
ThinSlab
285 ft2
(2) 200' Lengths of 1/2"
RadiantPEX+
Zone 10 <> Room List (HALL/ POWDER/ LAUNDRY)
Radiant Heating
ThinSlab
237 ft2
(2) 200' Lengths of 1/2"
RadiantPEX+
Zone l l <> Room List (ENTRY FOYER/ STAIRS/ POWDER RM, MUDROOM, OFFICE, MASTER LAUNDRY)
Radiant Heating
ThinSlab
691 ft2
(4) 200' Lengths of 1/2"
RadiantPEX+
Zone 12 <> Room List (MASTER BEDRM / CLOSET)
Radiant Heating
ThinSlab
445 ft2
(3) 200' Lengths of 1/2"
RadiantPEX+
Zone 13 <> Room List (MASTER BATH)
Radiant Heating
ThinSlab
265 ft2
(2) 200' Lengths of 1/2"
RadiantPEX+
Zone 14 <> Room List (WORKOUT ROOM / BATH)
Radiant Heating
ThinSlab
564 ft2
(3) 200' Lengths of 1/2"
RadiantPEX+
Zone 15 <> Room List (KITCHEN / PANTRY)
Radiant Heating
ThinSlab
475 ft2
(3) 200' Lengths of 1/2"
RadiantPEX+
Zone 16 <> Room List (BILLIARD RM, LIVING ROOM, DINING
ROOM)
Radiant Heating
ThinSlab
1042 ft2
(6) 200' Lengths of 1/2"
RadiantPEX+
Heating Load Summary
Tube
Back/Edge
Total
Total Supp.
Spacing
Intensity Losses
Required
Provided Needed
Zone
8792
63831
GARAGE NW WING 12
10.96 3.79
8792
63831
Zone 2
9568
57357
GARAGE S.W. WING 12
13.29 3.82
9568
57357
Zone 3
13715
76051
GARAGE CENTRAL 12
14.33 3.82
13715
76051
Zone 4
16757
114408
GARAGE EAST WING 12
11.6 3.80
16757
114408
Zone 5
16751
58539
UPPER GARAGE 12
22.7 5.47
16751
58539
CUiv MiNGS RES.rad Copyright(c) Watts Radiant 2008
Page 2 of 4
RadiantWorks Professional Mechanical Summary Report 7/30/2012
Zone 6
Total Flow:
21.7 GPM
11034
34720
FAMILY ROOM
12
13.04
1.31
11034
34720
Zone 7
5599
16089
BEDROOM / CLOSET #1
12
17.66
1.40
5086
10521
BATH #1
12
6.41
1.39
513
5568
Zone 8
5906
18566
BEDROOM / CLOSET #2
12
18.18
1.43
5310
10667
CLOSET #2
12
6.41
1.62
596
7899
Zone 9
6553
13552
BEDROOM / CLOSET #3
12
22.52
1.64
4548
7388
BATH #3
12
24.16
1.58
2005
6164
Zone 10
1519
16334
HALL / POWDER / LAUNDRY
12
6.41
1.42
1519
16334
Zone 11
16984
52104
ENTRY FOYER / STAIRS / POWDER RM
12
26.35
2.13
11885
37635
MUDROOM
12
20.24
1.52
1983
7269
OFFICE
12
24.44
1.71
2126
3358
MASTER LAUNDRY
12
18
1.53
990
3842
Zone12
8314
16237
MASTER BEDRM / CLOSET
12
18.68
1.44
8314
16237
Zone13
6571
19500
MASTER BATH
12
24.8
1.57
6571
19500
Zone 14
16086
22389
WORKOUT ROOM/ BATH
12
28.52
1.83
16086
22389
Zone 15
9492
34790
KITCHEN / PANTRY
12
19.98
1.49
9492
34790
Zone16
36924
41433
BILLIARD RM
12
29.13
1.83
9875
13482
LIVING ROOM
12
47.11
2.61
14603
12331 YES
DINING ROOM
12
31.67
1.93
12446
15620
Project Summary
Total Flow:
21.7 GPM
Total System Head:
2.5 ft
Boiler Load:
216589 BTU /h
Total System Volume:
119 Gallons
Total Heated Area:
10265 ftZ
CUMMINGS RES.rad Copyright(c) Watts Radiant 2008 Page 3 of 4
.IE ATING DESIGN INFORMATION SHEET �
� SEN DING BRANCH: SILVERTHORNE �
CONTRACTOR:
f
ACCOUNT #.
PHONE #:
PHONE M �l -
CONTACT: JCELL
JOB NAME:
J C4 o y��f L,-q 11 'e -
DATE:
2-0( 2
JOB SITE ELEVATION:
C/ -?,/) U
BOILER PREFERENCE:
BUDERUS
BURNHAM
LAARS
TRIANGLE TUBE
TRIANGLE COMBO
WRITE IN ANY UNLISTED. BOILER BELOW
ATMOSPHERIC
G124, G234, G334
ATMOSPHERIC
2B, 8 SERIES
ATMOSPHERIC
JV, HK
SEALED COMB
PG SERIES
CONDENSING
EXCELLENCE 110
SEALED COMB
GA124, GA244
SEALED COMB
RV OR SP
POWER VENT
JVH
CONDENSING
PRESTIGE
CONDENSING
GB142
SEALED COMB
PNCH
FUEL TYPE:
NATURAL
ELECTRIC
H:!;AT DISTRIBUTION:
RADIANT \
BASEBOARD
FAN COILS
RADIATORS
RADIAiaT FRAMED FLOORS ARE: ��
LT CONCRETE
GYPCRE?E
S' 2N ON GRADE
S'lAPI.ED UP
WATER HEATER TYPE:
INDIRECT \
ELECTRIC
BOILERiSTORAGE TANK
IF INDIRECT .PREFERENCE:
TRIANGLE TUBE
SUPERSTOR
BUDERUS
BRADFORD WHITE
TYPE OF GARAGE HEAT:
RADIANT
BASEBOARD
UNIT HEATER
NO HEAT
LIST ANY S(N�OWMELT AREAS:
LIST ANY COMMENTS OR SPECIAL INSTRUCTION :
JJ d W41 r k] 1/G !`1
2.
2. iG�
/tai G f4
3.
3. 7
4G /
pt
5.
5.
6.
6.
7.
7.
PLEASE PROVIDE DETAILED DESCRIPTION
OF HEATING REQUIREM.EN'I'S FOR REMODELS AND ADDITIONS TO EXISTING HOMES.
5////2
Cagl e/SummLt Uecf n Lc Co. Lnc. I Lc3578 pa./ o� /
Randy % Lngl e col o maaf en 4395
C.Lect n Lcal Load Cal cul of Lon
4936 Yuntpen
.Lot 6 aLh. / BLaAoan 5fh. addLtLon
VaLl CoLonado
7981 aq. ' @ 3va. pen
/ -hot tub 24ov
/ -wall oven
2- laundng cLA.
2- diahwaahen @ 1200ea.
3- appl Lance CLA @ 1500 ea.
/- ateam ahowen
boLlen and pumper
300' anow melt @ 6va. pen '
/- centnaL vac,
/- elevators
total va.
/af /0,000 va. @ 100%
bal. 64, 883 va. @40%
total demand 35,953 va.
35,953 va. clLvLded by 240v =149 amp
houae meteALng to be 325 amp cont. /0 w/ 2 panels
23,943 va.
9, 600 va
8, 000 va.
3, 000 va.
2, 400 va.
4 500 va.
9, 600 va.
000 va.
800 va.
/, 920 va.
9, /20 va
---------- - - - - --
74,883 va.
CNJ(
Energy Code:
Location:
Construction Type:
Building Orientation:
Glazing Area Percentage
Heating Degree Days:
Climate Zone:
Construction Site:
Juniper Lane
Vail, CO
REScheck Software Version 4.4.3
Compliance Certificate
2009 IECC
Vail, Colorado
Single Family
Bldg. orientation unspecified
19%
9248
6
Owner /Agent:
Compliance:
Compliance: 13.0% Better Than Code Maximum UA: 965 Your UA: 840
The % Better or Worse Than Code index reflects how close to compliance the house is based on code trade -off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home.
Ceiling 1: Cathedral Ceiling
Ceiling 2: Flat Ceiling or Scissor Truss
Floor 1: All -Wood Joist/Truss:Over Unconditioned Space
Wall 1: Wood Frame, 16" o.c.
Orientation: Unspecified
Window 2: Wood Frame:Double Pane with Low -E
SHGC: 0.00
Orientation: Unspecified
Designer /Contractor:
5023
47.0
0.0
111
764
47.0
0.0
20
1600
47.0
0.0
35
6806
23.0
0.0
304
1275
0.290
370
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in
REScheck Version 4.4.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
// 2 1 fi
Rame - Titlej — ignat Date
Project Title:
Data filename: C: \Documents and Settings \Owner\My Documents\REScheck \Juniper Lane.rck
Report date: 08/09/12
Page 1 of 4
t2TREScheck Software Version 4.4.3
Inspection Checklist
Energy Code:
2009 IECC
Location:
Vail, Colorado
Construction Type:
Single Family
Building Orientation:
Bldg. orientation unspecified
Glazing Area Percentage:
19%
Heating Degree Days:
9248
Climate Zone:
6
Ceilings:
❑ Ceiling 1: Cathedral Ceiling,
R-47.0 cavity insulation
Comments:
❑ Ceiling 2: Flat Ceiling or Scissor Truss, R-47.0 cavity insulation
Comments:
Above -Grade Walls:
❑ Wall 1: Wood Frame, 16" o.c., R -23.0 cavity insulation
Comments:
Windows:
❑ Window 2: Wood Frame:Double Pane with Low -E, U- factor: 0.290
For windows without labeled U- factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Floors:
❑ Floor 1: All -Wood Joist/Truss:Over Unconditioned Space, R-47.0 cavity insulation
Comments:
Floor insulation is installed in permanent contact with the underside of the subfloor decking.
Air Leakage:
❑ Joints (including rim joist junctions), attic access openings, penetrations, and all other such openings in the building envelope that are
sources of air leakage are sealed with caulk, gasketed, weatherstripped or otherwise sealed with an air barrier material, suitable film or
solid material.
❑ Air barrier and sealing exists on common walls between dwelling units, on exterior walls behind tubs /showers, and in openings between
window /doorjambs and framing.
❑ Recessed lights in the building thermal envelope are 1) type IC rated and ASTM E283 labeled and 2) sealed with a gasket or caulk
between the housing and the interior wall or ceiling covering.
❑ Access doors separating conditioned from unconditioned space are weather - stripped and insulated (without insulation compression or
damage) to at least the level of insulation on the surrounding surfaces. Where loose fill insulation exists, a baffle or retainer is installed
to maintain insulation application.
Wood - burning fireplaces have gasketed doors and outdoor combustion air.
Automatic or gravity dampers are installed on all outdoor air intakes and exhausts.
Air Sealing and Insulation:
❑ Building envelope air tightness and insulation installation complies by either 1) a post rough -in blower door test result of less than 7
ACH at 50 pascals OR 2) the following items have been satisfied:
(a) Air barriers and thermal barrier: Installed on outside of air - permeable insulation and breaks or joints in the air barrier are filled or
repaired.
(b) Ceiling /attic: Air barrier in any dropped ceiling /soffit is substantially aligned with insulation and any gaps are sealed.
(c) Above -grade walls: Insulation is installed in substantial contact and continuous alignment with the building envelope air barrier.
(d) Floors: Air barrier is installed at any exposed edge of insulation.
Project Title: Report date: 08/09/12
Data filename: C: \Documents and Settings \Owner \My Documents\REScheck\Juniper Lane.rck Page 2 of 4
(e) Plumbing and wiring: Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing, or
sprayed /blown insulation extends behind piping and wiring.
(f) Corners, headers, narrow framing cavities, and rim joists are insulated.
(9) Shower /tub on exterior wall: Insulation exists between showers /tubs and exterior wall.
Sunrooms:
Ej Sunrooms that are thermally isolated from the building envelope have a maximum fenestration U- factor of 0.50 and the maximum
skylight U- factor of 0.75. New windows and doors separating the sunroom from conditioned space meet the building thermal envelope
requirements.
Materials Identification and Installation:
F1 Materials and equipment are installed in accordance with the manufacturer's installation instructions.
F-I Materials and equipment are identified so that compliance can be determined.
F1 Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
r-i Insulation R- values and glazing U- factors are clearly marked on the building plans or specifications.
Duct Insulation:
F-1 Supply ducts in attics are insulated to a minimum of R -8. All other ducts in unconditioned spaces or outside the building envelope are
insulated to at least R -6.
Duct Construction and Testing:
I Building framing cavities are not used as supply ducts.
F-I All joints and seams of air ducts, air handlers, filter boxes, and building cavities used as return ducts are substantially airtight by means
of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Tapes, mastics, and fasteners are rated UL 181A or
UL 181B and are labeled according to the duct construction. Metal duct connections with equipment and /or fittings are mechanically
fastened. Crimp joints for round metal ducts have a contact lap of at least 1 1/2 inches and are fastened with a minimum of three
equally spaced sheet -metal screws.
Exceptions:
Joint and seams covered with spray polyurethane foam.
Where a partially inaccessible duct connection exists, mechanical fasteners can be equally spaced on the exposed portion of the
joint so as to prevent a hinge effect.
Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa).
Lj Duct tightness test has been performed and meets one of the following test criteria:
(1) Postconstruction leakage to outdoors test: Less than or equal to 8 cfm per 100 ft2 of conditioned floor area.
(2) Postconstruction total leakage test (including air handler enclosure): Less than or equal to 12 cfm per 100 U.
(3) Rough -in total leakage test with air handler installed: Less than or equal to 6 cfm per 100 ft2 of conditioned floor area.
(4) Rough -in total leakage test without air handler installed: Less than or equal to 4 cfm per 100 ft2 of conditioned floor area.
Temperature Controls:
Where the primary heating system is a forced air - furnace, at least one programmable thermostat is installed to control the primary
heating system and has set - points initialized at 70 degree F for the heating cycle and 78 degree F for the cooling cycle.
❑ Heat pumps having supplementary electric- resistance heat have controls that prevent supplemental heat operation when the
compressor can meet the heating load.
Heating and Cooling Equipment Sizing:
Additional requirements for equipment sizing are included by an inspection for compliance with the International Residential Code.
For systems serving multiple dwelling units documentation has been submitted demonstrating compliance with 2009 IECC Commercial
Building Mechanical and /or Service Water Heating (Sections 503 and 504).
Circulating Service Hot Water Systems:
J Circulating service hot water pipes are insulated to R -2.
1-1 Circulating service hot water systems include an automatic or accessible manual switch to turn off the circulating pump when the
system is not in use.
Heating and Cooling Piping Insulation:
❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to R -3.
Swimming Pools:
Heated swimming pools have an on /off heater switch.
Pool heaters operating on natural gas or LPG have an electronic pilot light.
Project Title: Report date: 08/09/12
Data filename: C:1Documents and SettingslOwnerlMy Documents\RESchecklJuniper Lane.rck Page 3 of 4
0 Timer switches on pool heaters and pumps are present.
Exceptions:
Where public health standards require continuous pump operation.
Where pumps operate within solar- and /or waste- heat - recovery systems.
Heated swimming pools have a cover on or at the water surface. For pools heated over 90 degrees F (32 degrees C) the cover has a
minimum insulation value of R -12.
Exceptions:
Covers are not required when 60% of the heating energy is from site - recovered energy or solar energy source.
Lighting Requirements:
L7 A minimum of 50 percent of the lamps in permanently installed lighting fixtures can be categorized as one of the following:
(a) Compact fluorescent
(b) T -8 or smaller diameter linear fluorescent
(c) 40 lumens per watt for lamp wattage — 15
(d) 50 lumens per watt for lamp wattage > 15 and — 40
(e) 60 lumens per watt for lamp wattage > 40
Other Requirements:
Snow- and ice- melting systems with energy supplied from the service to a building shall include automatic controls capable of shutting
off the system when a) the pavement temperature is above 50 degrees F, b) no precipitation is falling, and c) the outdoor temperature is
above 40 degrees F (a manual shutoff control is also permitted to satisfy requirement's').
Certificate:
F-1 A permanent certificate is provided on or in the electrical distribution panel listing the predominant insulation R- values; window
U- factors; type and efficiency of space- conditioning and water heating equipment. The certificate does not cover or obstruct the visibility
of the circuit directory label, service disconnect label or other required labels.
NOTES TO FIELD: (Building Department Use Only)
Project Title: Report date: 08/09/12
Data filename: C:\Documents and Settings \Owner \My Documents\REScheck\Juniper Lane.rck Page 4 of 4
CJ/ 2009 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
Ceiling / Roof 47.00
Wall 23.00
Floor / Foundation 47.00
Ductwork (unconditioned spaces):
Window
Door
0.29
Heating & Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Comments