Loading...
HomeMy WebLinkAboutB12-0377 ASBESTOS TEST Indoor Environmental Services, Inc Project: 600 Vail Valley Drive, Unit O Pinos Del Norte Vail, Colorado Asbestos Sampling Report — Page 1 of 2 August 15, 2012 Warren Nedbo Construction On August 13, 2012, Quentin Danziger conducted an asbestos inspection of the suspect materials to be effected by a planned remodel. Asbestos was NOT found, as described below. Homogenous Description Number of % Asbestos Square Type/Friable? Area Sam les Feet O1 Texture 3 Non-Detect 02 Sheetrock/ 3 Non-Detect Joint Com ound 03 Kitchen 3 Non-Detect Floorin BACKGROUND: A remodel is planned for the kitchen of this single-family residence. Indoor Environmental Services was requested to conduct an asbestos inspection of the suspect materials to be effected. This inspection includes only suspect materials that are visible to the inspector. If other suspect materials become visible during demolition, they must be sampled before they are disturbed. Examples of suspect materials include but are not limited to: linoleum, floor tile, ceiling tile, mastic, sheetrock,joint compound, roofing materials, etc. There are over 3000 known asbestos containing materials. SAMPLING PLAN: Colorado State Requirements - For each homogenous area of less than 1000 square feet, a minimum of three samples must be collected in random areas. For each homogenous area of 1000—5000 square feet, a minimum of five samples must be collected in random areas. Areas of 5001 square feet or greater require a minimum of 7 samples. These laws are defined by the EPA (AHERA) and Colorado State Regulation 8. Indoor Environmental Services, Inc Project: 600 Vail Valley Drive, Unit O Pinos Del Norte Vail, Colorado Asbestos Sampling Report — Page 2 of 2 Determination of homogenous sampling areas —Homogenous Areas are determined by type of suspect material, texture, color and location. Determination of random sampling areas —The samples were collected in a random manner within each homogenous area. Thank you for using Indoor Environmental Services, Inc. We are proud to be your local indoor air quality consultants. We look forward to working with you in the future. Quentin Danziger, BS, ABI—Colorado Asbestos Inspector Certification # 12781 Indoor Environmental Services, Inc. 970-390-0087 ColoradoAsbestos.com 221202994 � Asbestos Chain of Custody Enns� aNa�v���;;�, iNC. EMSL Order Number�cae use o�ry�: i oi o vuMn sr. DFNVER,CO 80204 e�na�wwwuricw�.i«c � P:yoNe: (303)740-5700 .:.:�:.�::;r.�:;�:...:�..q r<<x: (3631741-14G�� A EMSL-Bill to: Same Different Compan • rH Q(O �N p �q SdCs II Bill lo is DiRerent note instluctlons in CommenLS° Stfeet: �d 36X Third Pa 6illin re uires writlen aufhorizafion 6om third a Ci : �'�' ✓q,.� ( State/Prwince: GO rp/POSWICode: �S/�s� Country: �%S _ _ _ Re ortTo Name : �ue.<,ti� .�4h2 i Pax#: j Tele hone#: 97�- 3 9 v� GO �� � Email Address: Q Con $�(n�. T ti c "�pv �,� ProedNamdNumber: co �/Qi� i/a (/c j�b'. u�� tr � •- �U�tioS � i � ,��oC- � Please Provide Results: ❑ Fax Emai Purchase Order: U.S.State Sam es Taken: around Time TAT O 5ons'-Please Check ��/� 3 Hours 6 Hours 24 Hrs � 48 Hrs 3 Da s 4 Da s 5 Da s 10 Da 'Fw TEM Air 3 hours/6 hours,please ca edule.'There is a premium cha�ge/or 3 Ho�r TEM AHERA w EPA Level!I TAT. You will be asked ro sign an aufhaization Iwm for this service. Anal sis can efed in aaoidance wi(h EMSCs Terms and Conddions located in the Ana/ ical PnCe Guide. PCM-Air TEM-Air TEM-Dust ❑ NIOSH 7400 ❑ AHERA 40 CFR, Part 763 ❑ Miaovac-ASTM D 5755 ❑ w/OSHA 8hr.TWA ❑ NIOSH 7402 ❑Wipe-ASTM D6480 i P • ulk re ortin limit ❑ EPA Level II ❑ Carpet Sonication(EPA 600/J-93/167) i P 00/R-93/11fi(<1%) ❑ IS010312 Soil/Rock/Vertniculite � ❑ PLM EPA NOB(<1°/a) TEM-Bulk ❑ PLM CARB 435-A(0.25%sensitivity) � Point Count ❑TEM EPA N08 ❑ P�M CARB 435-B(0.1°/a sensitivity) � ❑400(<0.25%,)� 1000(<0.1%) ❑ NYS NOB 198A(norrfriable-NY) ❑ TEM CARB 435-8(0.1%se�sitivtty) � Poinl Count w/Gravimetric ❑ Chalfietd SOP ❑ TEM CARB 435-C(0.01%sensifivity) i ❑400(<0.25°/a)❑ 1000(<0.1%) ❑TEM Mass AnalysisEPA 600 sec.2.5 ❑ EPA Protocd (Semi-Quantitative) ❑ NYS 198.1 (friable in NY) TEM-Water. EPA 100.2 ❑ EPA Protocd(Quantitative) � ❑ NYS 198.6 NOB(non-fnaWe-NY) Fibers>10Um ❑Waste ❑ Drinking I Other: �' I ❑ NIOSH 9002(<i°ro� ai F�ne�s�ze5 ❑Waste ❑ od�w�9 '�; ❑ , ❑ Check For Positive Stop-Clearly Identify Homogenous Group � � Samplers Name: Sampiers Signature: � Volume/Area(Air) DateTme Sample# Sample Descriptio� HA#(Bulk) Sampled (� �-Z'i� �e-XT�-c.,r`E �'-/.�-/Z- ' �1—O Z- � o .' 3� I 0 /-03 6 z��'� � �T�o c,F J�.tiT C'�,,, ��d�Y<�� � bZ —o Z I bz -b3 i 0 3—� ( iFi-r-�-�,Q�, '/o� r,'/� a 3—�� � �/ Client Sample q(s): C>(-c�/ - O .3 -�' 3 Total#of Sam les: `j Relinquished(Client): Q Date: -�3-�Z Time: ��� yr i /'� Received(La6): Date: � Time: (J R Q Comments/Spe al 1 �� ^ ._� �,^^,� A�� �� j� �G���� �a+������-K�s+�• -a,-��� Page 1 of I pages 221202994 1 � Asbestos Chain of Custody �r��������f''=��, ����- EMSL Order Number��ab usa nly): 1010 Yurutr Sr � � DENVER, CO 80204 e�na�www�rrrew�,ixc. ProNE: (303)740-5700 a.��;�::..-.��...�; Fax: (303)741-?4i)0 Additional Pages of the Chain of Custody are only necessary if needed for additional sample information Volume/Area(Air) OateTme Sam le# Sam le Descri tion HA# Bulk Sam led Z1-3�OS /t /'�z�C-, �lo�' -,— ..� � •CommentslSpecial I nstructions: Page_of_pages (:q4Wed Wzr2M-M1SE¢NUt LCC-fl1-NYKW EMSL Analytical, Inc. EMSL Order: 221202994 1010 Yuma Street,Denver,CO 80204 CustomerlD: INES78 Phone/Fax: (303)740-5700/(303)741-1400 CustomerPO: httq://www.emsl.com denverlab@emsl.com ProjectlD: Attn: Quentin Danziger Phone: (970)390-0087 Indoor Environmental Services, Inc. Fax: P.O. Box 997 Received: 08/14/12 10:15 AM Vail, CO 81658 Analysis Date: 8/14/2012 Collected: 8/13/2012 Project: 600 Vail Valley Dr.Unit O-Pinos Del Notre Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy Non-Asbestos Asbestos Sample Description Appearance % Fibrous % Non-Fibrous % Type 01-01-Texture1 Texture White/Cream 100% Non-fibrous(other) None Detected zzizozssa-000i Non-Fibrous Heterogeneous Inseparable paint/coating layer included in analysis 01-01-Texture 2 Texture White 100% Non-fibrous(other) None Detected 221202994-OOOIA Non-Fibrous Heterogeneous Inseparable paint/coating layer included in analysis 01-02-Texture 1 Te�ure White/Cream 100% Non-fibrous(other) None Detected zzizozssa-000z Non-Fibrous Heterogeneous Inseparable paint/coating layer included in analysis 01-02-Texture 2 Te�ure White 100% Non-fibrous(other) None Detected zzizozssa-000za Non-Fibrous Heterogeneous Inseparable paint/coating layer included in analysis 01-03-Texture 1 Te�ure White 100% Non-fibrous(other) None Detected zzizozssa-000s Non-Fibrous Heterogeneous Inseparable paint/coating layer included in analysis 01-03-Texture 2 Te�ure White 100% Non-fibrous(other) None Detected 221202994-0003A Non-Fibrous Heterogeneous Inseparable paint/coating layer included in analysis r -F' � ,"�. � , Analyst(s) � ` ` � �L !�/� Breena Frederick(8) Erin Orthun,Laboratory Manager Donna Nading(18) or other approved signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analy[ical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal government Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless othervvise noted. Estimated accuracy,precision and uncertainty data available upon request.Unless requested by the client,building materials manufactured with multiple layers(i.e.linoleum,wallboard,etc.)are reported as a single sample.Reporting limit is 1% Samples analyzed by EMSL Analytical,Ina Denver,CO NVLAP Lab Code 200828-0 Initial report from 08/14/2012 15:57:36 Test Reeort PLM-7.16.0 Printed:8/14/2012 3:57:36 PM � EMSL Analytical, Inc. EMSL Order: 221202994 1010 Yuma Street,Denver,CO 80204 CustomerlD: INES78 Phone/Fax: (303)740-5700/(303)741-1400 CustomerPO: httq://www.emsl.com denverlab@emsl.com ProjectlD: Attn: Quentin Danziger Phone: (970)390-0087 Indoor Environmental Services, Inc. Fax: P.O. Box 997 Received: 08/14/12 10:15 AM Vail, CO 81658 Analysis Date: 8/14/2012 Collected: 8/13/2012 Project: 600 Vail Valley Dr.Unit O-Pinos Del Notre Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy Non-Asbestos Asbestos Sample Description Appearance % Fibrous % Non-Fibrous % Type 02-01-Texture Sheetrock/Joint White 100% Non-fibrous(other) None Detected Compound Non-Fibrous 221202994-0004 Heterogeneous Inseparable paint/coating layer included in analysis 02-01-Tape Sheetrock/Joint White 100% Cellulose 0% Non-fibrous(other) None Detected Compound Fibrous 221202994-0004A Homogeneous 02-01-Joint Sheetrock/Joint White 100% Non-fibrous(other) None Detected Compound Compound Non-Fibrous 221202994-00048 Homogeneous 02-01-Drywall Sheetrock/Joint Brown/White 10% Cellulose 88% Non-fibrous(other) None Detected zzizozss4-0004c Compound Fibrous 2% Glass Heterogeneous 02-02-Texture Sheetrock/Joint White 100% Non-fibrous(other) None Detected Compound Non-Fibrous 221202994-0005 Heterogeneous Inseparable paint/coating layer included in analysis 02-02-Tape Sheetrock/Joint White 100% Cellulose 0% Non-fibrous(other) None Detected Compound Fibrous 221202994-OOOSA Homogeneous 02-02-Joint Sheetrock/Joint White 100% Non-fibrous(other) None Detected Compound Compound Non-Fibrous 221202994-00058 Homogeneous r -F' � ,"�. � , Analyst(s) � ` ` � �L !�/� Breena Frederick(8) Erin Orthun,Laboratory Manager Donna Nading(18) or other approved signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analy[ical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal government Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless othervvise noted. Estimated accuracy,precision and uncertainty data available upon request.Unless requested by the client,building materials manufactured with multiple layers(i.e.linoleum,wallboard,etc.)are reported as a single sample.Reporting limit is 1% Samples analyzed by EMSL Analytical,Ina Denver,CO NVLAP Lab Code 200828-0 Initial report from 08/14/2012 15:57:36 Test Reeort PLM-7.16.0 Printed:8/14/2012 3:57:36 PM 2 EMSL Analytical, Inc. EMSL Order: 221202994 1010 Yuma Street,Denver,CO 80204 CustomerlD: INES78 Phone/Fax: (303)740-5700/(303)741-1400 CustomerPO: httq://www.emsl.com denverlab@emsl.com ProjectlD: Attn: Quentin Danziger Phone: (970)390-0087 Indoor Environmental Services, Inc. Fax: P.O. Box 997 Received: 08/14/12 10:15 AM Vail, CO 81658 Analysis Date: 8/14/2012 Collected: 8/13/2012 Project: 600 Vail Valley Dr.Unit O-Pinos Del Notre Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy Non-Asbestos Asbestos Sample Description Appearance % Fibrous % Non-Fibrous % Type 02-02-Drywall Sheetrock/Joint Brown/White 10% Cellulose 90% Non-fibrous(other) None Detected Compound Fibrous 221202994-0005C Heterogeneous 02-03-Te�ure Sheetrock/Joint White 100% Non-fibrous(other) None Detected Compound Non-Fibrous 221202994-0006 Heterogeneous Inseparable paint/coating layer included in analysis 02-03-Tape Sheetrock/Joint White 100% Cellulose 0% Non-fibrous(other) None Detected Compound Fibrous 221202994-0006A Homogeneous 02-03-Joint Sheetrock/Joint White 100% Non-fibrous(other) None Detected Compound Compound Non-Fibrous 221202994-00068 Homogeneous 02-03-Drywall Sheetrock/Joint Brown/White 10% Cellulose 90% Non-fibrous(other) None Detected Compound Fibrous 221202994-0006C Heterogeneous 03-01-Floor Tile Kitchen Floor Tile Brown 100% Non-fibrous(other) None Detected z2�zo2ss4-000� Non-Fibrous Heterogeneous 03-01-White Kitchen FloorTile White 100% Non-fibrous(other) None Detected Backing Non-Fibrous 221202994-0007A Homogeneous r" -F' � ,"�. � , ���/ � — ��'�L-z`T'i_.- Analyst(s) , ` Breena Frederick(8) Erin Orthun,Laboratory Manager Donna Nading(18) or other approved signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analy[ical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal government Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless othervvise noted. Estimated accuracy,precision and uncertainty data available upon request.Unless requested by the client,building materials manufactured with multiple layers(i.e.linoleum,wallboard,etc.)are reported as a single sample.Reporting limit is 1% Samples analyzed by EMSL Analytical,Ina Denver,CO NVLAP Lab Code 200828-0 Initial report from 08/14/2012 15:57:36 Test Reeort PLM-7.16.0 Printed:8/14/2012 3:57:36 PM 3 EMSL Analytical, Inc. EMSL Order: 221202994 1010 Yuma Street,Denver,CO 80204 CustomerlD: INES78 Phone/Fax: (303)740-5700/(303)741-1400 CustomerPO: httq://www.emsl.com denverlab@emsl.com ProjectlD: Attn: Quentin Danziger Phone: (970)390-0087 Indoor Environmental Services, Inc. Fax: P.O. Box 997 Received: 08/14/12 10:15 AM Vail, CO 81658 Analysis Date: 8/14/2012 Collected: 8/13/2012 Project: 600 Vail Valley Dr.Unit O-Pinos Del Notre Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy Non-Asbestos Asbestos Sample Description Appearance % Fibrous % Non-Fibrous % Type 03-01-Mastic Kitchen FloorTile Tan 100% Non-fibrous(other) None Detected zzizozssa-000�e Non-Fibrous Homogeneous 03-02-Floor Tile Kitchen Floor Tile Brown 100% Non-fibrous(other) None Detected zzizozssa-000s Non-Fibrous Heterogeneous 03-02-White Kitchen FloorTile White 100% Non-fibrous(other) None Detected Backing Non-Fibrous 221202994-OOO8A Homogeneous 03-02-Clear Kitchen Floor Tile Clear 100% Non-fibrous(other) None Detected Adhesive Non-Fibrous 221202994-00088 Homogeneous 03-03-Floor Tile Kitchen Floor Tile Brown 100% Non-fibrous(other) None Detected zzizozssa-000s Non-Fibrous Heterogeneous 03-03-White Kitchen FloorTile White 100% Non-fibrous(other) None Detected Backing Fibrous 221202994-0009A Homogeneous r -F' � ,"�. � , Analyst(s) � ` ` � �L !�/� Breena Frederick(8) Erin Orthun,Laboratory Manager Donna Nading(18) or other approved signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analy[ical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal government Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless othervvise noted. Estimated accuracy,precision and uncertainty data available upon request.Unless requested by the client,building materials manufactured with multiple layers(i.e.linoleum,wallboard,etc.)are reported as a single sample.Reporting limit is 1% Samples analyzed by EMSL Analytical,Ina Denver,CO NVLAP Lab Code 200828-0 Initial report from 08/14/2012 15:57:36 Test Reeort PLM-7.16.0 Printed:8/14/2012 3:57:36 PM THIS IS THE LAST PAGE OF THE REPORT. 4