HomeMy WebLinkAboutB12-0365 SPEC SHEET FOR INTUMESCENT SEALANT • ■ � 1 1 � � Specseal,�o!I�Ill�i� SERIES LCI INTUMESCENT SEALANT APPLICATIONS PRODUCT DESCRIPTION SpecSealO LCI Sealant has a broatl application SpecSealO LCI Sealant is a versatile and economical intumescent product intended for firestopping a base tlesignetl to seal a wide variety of common wide array of applications in small commercial or grouped residential construction and other structures penetrations in light commercial antl groupetl with similar applications. SpecSealO LCI Sealant is available in a single grade that has excellent caulk- resitlential construction. Penetrant types inclutle ing properties as well as high build properties on vertical or overheatl surfaces.This single grade may be insulatetl antl non-insulatetl metallic pipes and caulked(standard cartridge or bulk loaded),knifed or troweled. In addition,SpecSealO LCI Sealant tloes tubes, non-metallic pipes antl tubes, and common not contain PCB's or asbestos. electrical service and power tlistribution,telephone, SpecSealO LCI Sealant is storage stable (when stored according to the manufacturer's recommentla- tlata, antl TV cabling.This protluct is also used in tions),and will not separate or shrink when dried.SpecSealO Series LCI Sealant will adhere to all com- conjunction with other SpecSealO Products such mon construction antl penetrant materials antl contains no solvents that might ativersely effect plastic as SpecSealO Firestop Collars antl Wrap Strips to pipes or cable jackets. protect larger plastic pipes. FEATURES See Table A for a summary application list. •Economical:High performance without the high price! •Highly Intumescent:Expantls up to 8 times. •Excellent Smoke Seal •Water Resistant:Will not re-emulsify when dry. •Water-Based for easy installation,cleanup,and disposal. _ �� •Acoustically Tested:Reduces noise transmission P I� •Safe...Low VOC's,No Solvents,Non-Halogenated � �.�.� •Paintable ��---- '� PERFORMANCE _ / SpecSealO LCI Sealant is the basis for systems that meet the exacting criteria of ASTM E814(UL1479) ,� and ASTM E1966(UL2079)as well as to the time-temperature requirements of ASTM E119(UL263).LCI I provides up to a 4-hour fire rating for typical service penetrations through concrete or wood floors,concrete � � \ or masonry walls,as well as gypsum board walls.SpecSealO LCI Sealant meets Class A finish require- '� ments for Flame Spread and Smoke Development when tested in accortlance with ASTM E84(UU23). � SpecSealO LCI Sealant is also acoustically tested,demonstrating excellent sound attenuation properties. � FBCT"' System Compatible indicates that this product has been tested, F�� and is monitored on an ongoing basis,to assure its chemical compatibility with FlowGuard GoIdOO,BlazeMasterOO and CorzanOO pipe and fittings. FBC, SYSTEM COMPATIBLE FlowGuard Gold, BlazeMaster and Corzan are licensed trademarks of The PHYSICAL PROPERTIES LubrizolCorporation. Properties Series LCI V�PSS'F�FO AND THROUGH-PEINE RATION FSR SR OP SYSTEIMS S SEE Ul Color Red u DIRECTORY OF PRODUCTS CERTIFIED FOR CANADA AND UL FM C �L US FIRE RESISTANCE DIRECTORY. APPROVED Odor Mild Latex 3L73 Density 9.0 Iblgal(1.08 kgiL) pH 90 SPECIFICATIONS In Service Temperature s 185°F(85°C) The firestopping sealant shall be a water-resistant,intumescent latex sealant.The sealant when exposetl Flame Spread o� to high heat or flame shall exhibit a free expansion of up to 8 times its original volume.The firestopping Smoke Developed 5" sealant shall contain no water soluble nor hygroscopic ingredients antl shall be acoustically testetl.The sealant shall be UL Classified and/or FM approvetl and tested to the requirements of ASTM E814(UL1479) STC Rating 62 and shall meet Class A finish requirements when tested in accordance with ASTM E84(UL723). (ASTM E90/ASTM C919) VOC Content 0291bs�gal(35.OgiL) (EPA Method 24/ASTM D3960) Shelf Life 2yrs SPECIFIED DIVISIONS Volume Expansion 10X Free Expansion DIV. 7 07840 Through-Penetration Firestopping DIV. 13 13900 Special Construction Fire Suppression&Supervisory Systems Storage Temp. 40°F(4°C)-95°F(35°C) DIV. 15 15250 Mechanical Insulation—Fire Protection 'Tested to ASTM E84(UL723)at 14%surface coverage(modified test for seaia�csanaca�iks) DIV. 16 16050 Basic Electrical Materials&Methods —"— Technical Service 1-800-992-1180 STI Product Data Sheet • Series L(I Intumescent Sealant • FOD-5062 05/2011 � STI� www•stifirestop.com Fig 1:METALLIC PIPES-ConcretelMasonry Floors&Walls Fig 2:INSULATED METALLIC PIPES-Concrete/Masonry Floors&Walls Steel ° ° Sleeve Metallic LCI LCI Mineral ° LCI Pipe Metallic Sealant LCI Sealant Sealant pipe ° Sealant Wool (goth Sides� Steel Concrete a� Sleeve Floor Steel Concrete Sleeve Floor � - o � a A. . Mineral Wool a Mineral a Wool o Concrete Insulated Concrete Wall Insulated Wall P�pe Assembly Metallic Pipe UL System No.C-AJ-1353 UL System No.W-J-1098 UL System No.C-AJ-5138 F Rating:3 Hr•T Rating:0 Hr F Rating:2 Hr•T Rating:ll4,3l4&1 Hr F Rating:2 Hr•T Rating:3/4 or 1 Hr Steel or Iron Pipe:<12",Copper Pipe:<4" Steel or Iron Pipe:<8",Copper Pipe:<4" Sieel or Iron Pipe:6",Copper Pipe:4" Annulus:0"to 2" Annulus:0"to 2" Pipe Covering:Max.2"fiber glass or mineral wool pipe insulation. Sealant Depth:l/4" Sealant Depth:5l8" Annulus:l/4"to 1-5/8"•Sealant:l/2" Forming Material:Nom 4 pcf mineral wool(21/4"Depth) Forming:Nom.4 pcf mineral wool(3"depth) SEALANT REQUIREMENTS IN CUBIC INCHES PER 1l4 INCH OF INSTALLED DEPTH* Pipe Size Diameter of Opening(in.) 1.5 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10 12 14 26 Trade Pipe Size O.D. 0.5" 0.840 0.3 0.6 1.6 3.0 4.8 6.9 9.5 12.4 19.5 28.1 38.3 132.6 'DifferentSealantDepih? 1" 1.315 0.1 0.4 1.4 2.8 4.6 67 9.3 12.2 19.3 27.9 38.1 132A ��p�� Multipryby2 1.5" 1.900 1.1 2.4 4.2 6.4 8.9 11.9 18.9 27.6 37.8 132.0 5/e" Multipryby2.5 2" 2.375 0.7 2.0 3.8 6.0 8.5 11.5 18.5 27.2 37.4 131.6 �" MWtiplyby4 2.5" 2.875 0.1 1.5 3.3 5.4 8.0 10.9 18.0 267 36.9 131.1 1-1/4" Multiplyby5 3" 3.500 0.7 2.5 4.7 7.2 10.2 17.2 25.9 36.1 130.3 3.5" 4.000 1.8 3.9 6.5 9.4 16.5 25.1 35.3 129.6 4" 4.500 0.8 3.0 5.6 8.5 15.6 24.2 34.4 128.7 6" 6.625 1.1 4.0 11.1 19.7 29.9 124.2 __. - �- -- -� - _ 8" 8.625 4.9 13.6 23.8 118.0 10" 10.750 5.6 15.5 110.0 12" 12.750 6.6 100.8 24" 24.000 19.6 IMPORTANT NOTE:This table is for estimation purposes oniy.Consult UL Fire Resistance Directory or STI Product&Application Guide for specific installation requirements and limitations Metric Estimation Table available upon request. Fig.3:ELECTRICAL,DATA OR COMMUNICATIONS-Gypsum Walls TABLE A: APPLICATIONS TESTED AND CLASSIFIED FOR FIRE RESISTANCE • Metallic Pipes including steel,iron,or copper Cable pipe and tubing. Bund\ I LCI Sealant LCI Sealant (Both Sides) Non-Metallic (Both sides) . Nonmetallic Pipes,Conduits&Tubing Conduit inclutling PVC,CPVC,ABS,antl PEX. • Electrical&Electronic Cabling including a 4 service entrance,power tlistribution,computer, telephone,antl television. Gypsum ': I G sum Metal Ductwork including HVAC,bath and Asslembid/ Wallboard dryer vents. y I Assembly • Insulated Pipes including heating,cooling, UL System No.W-L-3169 UL System No.W-L-2241 antl condensation applications. F Rating:l,2 Hr•T Rating:o antl o F Rating:l,2 Hr•T Rating:0,0,1,1-3/4 Complete Wood Floor firestopping package Up to 4-1/2""cable bundle <2""Rigid PVC or ENMT,CPVC,ABS , for electrical, lumbin HVAC,tele hone,antl Annulus:0""too"•Sealant:5/8"" Annulus:0-1""•Sealant5/8"" P 9� P television. 2 STI Product Data Sheet • Series LCI Intumescent Sealant • FOD-5062 05/2011 Technical Service 1-800-992-1180 -"- www.stifirestop.com STI$ INSTALLATION INSTRUCTIONS GENERAL:Areas to be protected must be clean and free of oil,loose dirt,rust or scale. Installation temperatures must be between 35°F(2°C)and 100°F (38°C).Allow protluct to tlry a minimum of 24 hours before exposure to moisture. SYSTEM SELECTION:Selection of an appropriate firestop system design is critical to the fire protection process.Space limitations preclude highly detailetl information pertaining to individual application systems.Please consult the Product&Application Guide as well as the ULOO Fire Resistance Directory for adtlitional information. FORMING:Some installations may require forming as either an integral part of the system or as an option to facilitate installation.In systems where forming is required,mineral wool batts with a minimum nominal density of 4 PCF(64 kg/m3)are generally required.Cut forming material oversize to allow for tight packing.Position forming material to allow for the proper depth of fill material. FILL MATERIAL:SpecSealO LCI Sealant may be installed by caulking using a standard caulking gun or from bulk containers using a bulk loading caulk gun,or by manually troweling using a mason's trowel or putty knife.If the sealant tends to pull back from a surface,clean the surface with a damp rag or sponge antl reapply.Work sealant into all areas exercising care to eliminate voitls or seams.The surface of the sealant can be smoothed using a putty knife tlippetl in water.Atltling water to the sealant itself is not recommentled.Sealant(when tlry)may be paintetl using most non-solvent based paints. Fig.4:BARE&INSULATED METALLIC PIPES-Wood Floor Assemblies In gypsum wallboard penetrations,apply a minimum cove bead of 1/4" (6 mm) at the interface of the penetrant with both exterior wall surfaces. Insulated Metallic ��� Metallic Pipe SMOKE SEALING:In some applications inclutling Pipe�- seaiant �ci firestop collars, SpecSealO LCI Sealant is � Sealant recommended as a smoke seal.It is suggested in these applications that the sealant be applied to both sides of walls. In floor applications,a sealing bead is suggested top and bottom. LIMITATIONS: SpecSealO LCI Sealant is water- based and cures through the evaporation of water. Low temperatures as well as high humidity may retartl drying.Non-porous or impermeable backing — , materials,plates,or coatings may retard the drying � process. Do not paint or seal in any way that pre- wooa Fioo� S a�lant �ci wo d Floor vents contact with air until sealant has drietl through Assembly Sealant Assembly completely. This product has been designetl to be UL System No.F-C-1074 UL System No.F-C-5043 safe with plastics antl has been usetl extensively and F Rating:1 &2 Hr•T Rating:n,o antl 1 Hr F Rating:1 &2 Hr•T Rating:a and 1 Hr successfully with a variety of different types of plastic Steel,Iron or Copper:4"'•Chase wall optional. Steel,Iron or Copper:4"' pipes,tubes,and plaStiC Cable insulati0ns.Variations Annulus:0"'to 1""•Sealant:5/8"�bottom,o"'top Pipe covering:1""Fiber Glass,Mineral fiber in these m8teridlS hOwever, mdke it impOSSible t0 or AB/PVC•Chase wall optional. guarantee compatibility. STI strongly recommends Annulus:0"'to 1"'•Sealant:5/8'"bottom,o"top. that the user consult with the manufacturer of the pipe, tubing, or cable in question regarding any known sensitivities or potential restrictions before applying this protluct. Fig.5:BARE&INSULATED METALLIC PIPES-Gypsum Walls LCI Sealant Metallic (Both Sides) Insulated LCI Sealant Pipe Metallic (Both Sides) LCI Sealant Pipe (Both Sides) I AC Line Gypsum Set Gypsum Gypsum Wallboard Wallboard Wallboard Assembly ��. Assembly Assembly UL System No.W-L-1222 UL System Nos.W-L-5121,W-L-5122 UL System No.W-L-8025 F Rating:1,2 Hr•T Rating:o,o,1 Hr F Rating:1,2 Hr•T Rating:1 Hr&1/4 Hr F Rating:1,2 Hr•T Rating:o Hr Steel or Iron pipe:8"",Copper pipe:4"" Steel or Iron pipe:6"",Copper pipe:4" AC Line Set:Two copper tubes, Annulus:0""to 2""•Sealant:5/8"" Pipe covering:Max.2""fiber glass, one with o`AB/PVC antl thermostat wire o""AB/PVC or 2""mineral fiber Annulus:0""to 1"'•Sealant 5/8"" Annulus:0""to 1-1/2""•Sealant:5/8"" —"— Technical Service 1-800-992-1180 STI Product Data Sheet • Series LCI Intumescent Sealant • FOD-5062 05/2011 3 STI� www•stifirestop.com MAINTENANCE No maintenance is normally required,however a periotlic inspection of rated barriers is recommentletl to make sure that any new openings,motlifications of previously installed firestops,or areas exhibiting physical damage,have been properly sealed or repaired.Subsequent sealing or repairs should be accomplishetl using SpecSealO products per the original approvetl design. RETROFIT:When adding or removing penetrants,care should be taken to minimize damage to the seal. Reseal using SpecSealO products per the approved design.NOTE:New penetrants of a different nature than the original tlesign may require a totally new firestop design or extensive modifications to the existing design.Reseal all openings as per the requirements of the modified tlesign. TECHNICAL SERVICE Specified Technologies Inc.provides toll free technical support to assist in product selection and appropriate installation tlesign. UL Systems, Material Safety Data Sheets antl other technical information is available through the Technical Library at www.stifiresto .n com. PRECAUTIONARY INFORMATION Consult Material Safety Data Sheet for additional information on the safe handling and disposal of this material. AVAILABILITY SpecSealO Series LCI Sealant is available from authorizetl STI distributors. Consult factory or website for the names antl locations of the nearest sales representatives or tlistributors. ORDERING INFORMATION �_� - --� CAT.N0. DESCRIPTION � W; LC1300 Sealant 10.1 oz Tube 18.2 Cu In(300 ml) � _"� ��� � � � �� LCI305 Sealant 5 Gal Pail 1,155 Cu In(19.0 Liters) � LCI320 Sealant 20 oz Sausage 36 Cu in.(592 ml) � ^ "' 0 '° � ° � LCI329 Sealant 29 oz Quart Tube 52 Cu in.(858 ml) additional SpecSeal Products... I Series SSS Sealant Firestop Mortar The industry's most versatile sealant provides the firestopping solutions for a wide range of Lightweight,versatile and economicali The best choice for large or complex installations. combustible and noncombustible applications.Water-based intumescent sealani expands up SSP Firestop Putty to 8X. Available both in bar form antl in pads,putty provitles easy retrofit for through-penetrations antl ImumesCerdWrapStrips economical protection for electrical boxes. Three gratles of intumescent wrap strips provide an unmatchetl combination of flexibility, economy,and expansion(up to 30X).Systems for plastic pipes induding FR Polypropylene up PenSiIOO SIflCOnes to 8"trade size! Sealants antl foam for through penetrations and construction joints.Unexcelled aging charac- SSC&LCC Firestop Collars teristics and flexibility. Easy to install,economical protection for ABS and PVC pipes(both solid and foam core)as ElastomeriC Joint Seals well as CPVC,PVDF,and FRPP.LCC Collars are available up to 4"and SSC Collars are avail- New economical products for sealing construction joints.Choose caulk or spray applied able up to 6"trade size. products tested to UL2079. IMPORTANT NOTICE: All statements,technical information,and recommendations contained herein are based upon testing believed to be reliable,but the accuracy and completeness thereof is not guaranteed. WARRANTY Specified Technologies Inc.manufactures its goods in a manner to be free of defects. Should any defect occur in its goods(within one year),Specified Technologies Inc.,upon prompt notification,will at its option,exchange or repair the goods or refund the purchase price. LIMITATIONS AND EXCLUSIONS: THIS WARRANTY IS IN LIEU OF ALL OTHER REPRESENTATIONS EXPRESSED OR IMPLIED(INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR USE)AND UNDER NO CIRCUMSTANCES SHALL SPECIFIED TECHNOLOGIES INC.BE RESPONSIBLE FOR ANY INCIDENTAL OR CONSEQUENTIAL PROPERTY DAMAGE OR LOSSES.PRIOR TO USE,THE USER SHALL DETERMINE THE SUITABILITY OF THE PRODUCT FOR ITS INTENDED USE,AND THE USER ASSUMES ALL RISKS AND LIABILITY FOR SUBSEQUENT USE. No statement or recommendation not contained herein shall have any force or effect unless in an agreement signed by officers of seller and manufacturer. MADE IN THE USA –COPYRIGHT �O 2011 SPECIFIED TECHNOLOGIES INC. _✓ Specified Technologies STI� Inc. Specified Technologies Inc.•210 Evans Way,Somerville,NJ 08876 USA•Phone:800.992.1180•Fax:908.526.9623 —� 4 STI Produci Data Sheet • Series LCI Iniumesceni Sealant • FOD-5062 05/2011 Technical Service 1-800-992-1180 www.stifirestop.com STI$