HomeMy WebLinkAboutMIDDLE CREEK VILLAGE FIRE WALLS LEGALTOI^/N OF VAIL FIRE DEP 75 S.FRONTAGEROAD VAIL, CO 81657 970-479-2135 OWNER TOhIN OF VAIL ? FTNANEE DEPT 75 S FROMTAGE RD vArL co 81657 Iricense : CONrRACTOR Riviera Blectric P,O, Box 1417 G)rpsum, CO 410 Mccregor, Ste. 210 Gypsun, CO 81637 I-,icense: 670-S APPLICAI{|II Riviera Electric P.O. Box L417 cl4)sum, CO 410 Mccregor, Ste. 2L0 Gypsum, CO 81537 License:570-S Desciption: Fire alarm system for Middle Creek. Valuation: $56,853.00 VAIL FIRE DEPARTMENT NOTE: THIS PERMT MUST BE POSTED ON TOBSITE AT ALL TIMES o ARTMENT ALARMPERMIT ]ob Address: 129 N FRONTAGE RD WEST VAIL Location.....: Mtur. Bell Site housing wf . .L\Le C^*l-ParcelNo...: 210706400002 ProjectNo : ilt5ot {)SOO 05/29/2OO4 Phone: Permit #: Ao4-0039 3o 3 "-O r V1 3os-or t- 7Status...: ISSUED Applied..: 06/29/2004 Issued. .: 07/01./2004 Expires. .: P/n/2004 06/29/2OO4 Phone: 97O-328-4LL]- 06/29/2004 Phone: 97o-328-4tLt FEE SUMMARY Electrical___> DRB Fee--> Investigation-> Will Call-----> TOTALFEES-> $2,366.99 s0.00 $0.00 $0.00 s3.00 Total Calculated Fees-> 52,366.99 AdditionalFees_> 92,366.99) Total Permit Fee._---> Pa)'menrc-----> BALANCE DUE-_> $0.00 $0 - 00 $0.o0 Approvals:I€dm: 05500 FfRE DEPARTIIIEIIII 06/29/2004 mcgee Action: AP Pre-wire only. CONDITIONSOF APPROVAL DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the inlormation as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoninS and subdivision codes, design review approved, Uniform Building Code and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION STTALL BE MADE TWENTY-FOUR HOURS IN ADVANCf, BY SIGNATURE OF FROM t:00 AM - 5 PM, CTOR FOR HIMSELF AND OWNET ApplrcAroN wrLL Nor BE AccEprED rF rNcoMpLEr. "'Ili"*r.= (1!{Otl9oo ft | ',:'"':ins permit *: Br.a - ol4e t\\t T )l Alarm Permit#: --_--97 0-47 9- 21 35 (l ns pecti o n s)nw*#l timeorT's. Frontage Rd. , application submittal and must include information listed oh the Vail, Colorado81657 2- page of this form. Application will not be accepted without this ,^ 1 finformation. , nl\54r'( (\\-,1 tQw / t ' coNTRAcroR TNFoRMAtoN n U \ Fire Alarm Contractor: Rivietr, EArr.;r- Town of Vail Reg. No.:]zr<{Contact and Phone #'s: /u/;k, Hu;nr.f zof-ozot E-Mail Address:4,K\hS!.^rr l@ ri't;c ra ip j , < o,, contrador sisnatwe: ..,-Z2Z ,/c(VALUATIONS FOR ALARM PENUT (Labor & Materials) Fire Alarm: g ..) J Contact Assessors Office at 970-328-8640 or visit www.eaqle-countv.com for Parcel # Parcer# ZIOlO$[OOU)/ ua Nane.1/;on[ Oeek Affi.r"l^tl, H,,,'1j nllJ Ary Job Address: izg il, F"'"frO, nJ Wetf V"il Legal Description ll Lot: ll Block: ll Filing:Subdivision: owners Name:ru.n ^ of d,' l/'/o -n^o*, Dnr ll Adoress' 7 S s F.*h, r &J ll enone: Engin"t.ly'uhu/n* 6"*"1 Sytl?n: llAddress:7Jsr S,Rn-,rrP,r**, U"if &i ll enone: (lzo) 615- OjOS Detailed Location of work: (i.e., floor, unit #, bldg. #)(-o^pleh F..o fl..- srs l=*,' f4.un4\ouT- 5.;l/;"r, ft,6+ C Detailed descriotion of work:(-o.lp/e/'z Ery Al,,^ €r<fon Work Class: New( Addition ( ) Remodel ( ) Repair ( ) Retro-fit ( ) Other ( ) Type of Bldg.: Single-family ( ) Twolamily ( ) Multi-family ffi Commerciat ( ) Restaurant ( ) Other( ) No. of Existing Dwelling Units in this building: /t/1 ll No. of Accommodation units in this building: _- DoesaFireAlarmExist: Yes( ) No( ) ,00+ ll OoesaFireSprinkterSystemExist Yes( ) Uo()/lf :e'trl***'k****************rt****'k*****:f****FOR OFFICE USE ONLY*****it**:f*******************:h******** \VAiMAIA\CdEV\FORMS\PERMITS\ALRMPERM.DOC 07?1/2002 TOWNOF VAIL FIRE DEPARTMENT 75 S.FRONTAGEROAD VAIL, CO 81657 9'70-479-2135 VAIL FIRE DEPARTMENT NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TMES SPRINKLERPERMIT Permit #: Job Address: 129 N FRONTAGE RD WEST VAIL Location.....: Mtn. Bell Site ParcelNo...: 210106400002 ProjectNo : TR$O(-OSoo ft\,&LU G-d- F04-0038 ISSUED 08/04/2004 08/26/2Q04 OWNER TOWN OF VAIL8 FTNANCE DEPT 75 S FRONTAGE RD VAIIJ CO 81651 I-,icense: 08/04/2004 Phone: CONTRACTOR ALL STAIE FIRE PROTECTION, I08/04/2004 Phone: 303-288-3901 5045 E 76TH *72 COMMERCE CITY CO 80022License:370-5 APPLICANT AI-,L STATE FIRE PROTECTION, I08/04/2004 Phone: 303-288-3901 6045 E 76''rH +I2 COMMERCE CITY CO 80022 License:370-S Desciption: SPRINKLER SYSTEM FOR BUILDING E Valuation: S12.000.00 Mechanical--> Plan Check--> Investigation-> Will Call----> *rtlfr++it*'lraat****tt:rt*,r*r'*:l:r***ttr**:|t* FEE SUMMAIIY l*****ar**.***.|****1*r**'**:l*ttri*r***'l*a**r*r******rrr*,1**j*** S0 . 00 Restuarant Plan Review-> S0 . 00 Total Calculated Fees--> 5863 . 00 $350.00 DRB Fee-----------> 50.00 Additional Fees------> (5863-00) S0.00 TOTAL FEES---..--> 5853.00 Total Permit Fee------> 50.00 53.00 Paymsnts--------------> S0.00 BALANCE DUE..--.-.-->s0.00 ItEm: O51OO BUILDING DEPARTMENTItem: 05600 FIRE DEPARTMENT 08/25/2004 mvauglhan Action: AP CONDITION OF APPROVAL Cond:12 (BLDG. ) : FIELD INSPECTIONS ARE REQUIRED T0 CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in fulI the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structur€ according to the towns zoning and subdivision codes, design review approved, Uniform Building Code and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVAI\CE BY TELEPHONE AT 479-2135 FROM 8:00 AM - 5 PM. TTJRE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER Fug O3 O4 O2:38p o p.3 9(uf .E.f. Level lll (min) stamp. Gontractor. ,,_ffiI 75 S. Frontage Rd. APPLICATTON W]LL !!hout this information:r- [ Nor BE AccEprED rF rNcoMpLErSjS$ ii".EJo I _ 6 B oO Bullding Permit #r Sprinkler Permit #: Fire Sprinlrler "fro .T:i""j,ii :ly-d?-rl"If l.oyi ns-. pe rmit i ppr i caro n wi l nbt o J.i"epiil' - " - cut calcu CoTTRACTOR tN rioRtlrATtoN Fi re S prinkte r Con tracto-i Contact and Fhonefb:- COMPLETE VALUATIONS FOR.ALARM PERMIT (Labor & Matertats) Assessors Otfice at RFCE, YEO 1l .com for Parcel # I t****************************n**o*****ffi]S, ,Ygnd**********jl*********************r** Detaited Location orworkr 1ie'- floorlnif#,@ Agproved ar Submltted D WorkClass; New() Addition( ) Remodel Repalr( ) Retro-fit( ) Other( ) Type of Bldg.: Stngte-famity ( ) Two-famlty 1 I ( ) Commerciat ( ) Restaurant ( ) Other ( ) No, ot Exisung Dwelltng Unlts in this bulldlng: Does a Fire Alarm Eiisi:--Tes ( l-T6 a Fire Sprinkler System Exlst:' Ves (J llo 1 I tirVoil\duto\cdcy:tORMSit'tiRI TS,SpRKpt.:RM.DOC TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S.FRONTAGEROAD vArL, co 81657 970-479-2r35 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES SPRINKLER PERMIT Permit #: F04-0010 Job Address: 129 N FRONTAGE RD WEST VAIL Status . . . : ISSUED Location.....: Mtn. Bell Site Applied. . : 03/0312004 ParcelNo...: 210106400002 Issued. . : 04/14/2004 ProjectNo : ---.,(S(*OtSod Expires. .: o$tNER TOWN OF VAIL O3/O3/20O4 phone: I FINANCE DEPT 75 S FROIITAGE RD vArrr co 81657 L,icense: coNrRAcToR AI_,L STATE FIRE PROTECTION, I03/03/2004 phone: 303-288-3901 6045 E 76rH #12 COMMERCE CITY CO aoo22 T.ricense: 37O-S APPL.,ICANT ALIJ STATE FIRE PROTECTION, I03/03/2004 Phone: 303-288-3901 6045 E 76TH *L2 COMMERCE CITY CO 80022 I-,icense: 370-S Desciption: Install sprinkler system in Middle Creek Affordable Housing Valuation: $300,000.00 'r,l.i:r *:f * ,t * t *:* t *:* :* * Mechanical-->S0 . 00 Restuarant Plan Review->$0.00 Total Calculated F€es--> $13,103 - 00 Plan Check--> $3 5 0 . 00 DRB Fee---------->$0. o0 Additional Fe€s----_> BALANCE DUE--_--> Payments------2 $13,103.00 $0. 00 $0.00 Investigation-> WiU Call----> $0 - 00 TOTAI FEES.-_--_> $13,103.00 Total Permit Fee._-.-> $13, r03.00 $3.00 Item: 05100 BUILDING DEPARTMEI{:I Item: 05500 FIRE DEPARTMENI 04/06/2004 mcgee Action: AP Conditrional Approval granted as noted: Conditions per BFPE are as follows: ]-.Provide Expans ion Tank Size, Calculations & Data sheets. 2.Add enlarged plan showing Backflow etc., at riser rootn (BIdg. C) 3.Add antifreeze/wet details and refer to floor plan locations to this detail 4.Learning Center Submittal . 5,Provide hydraul ic data plates 6.provi.de QR heads in areas outside dwelling units. BIdg A FP-3 & FP-4; Bldg B FP 7.No FDc shown on Bldg A or Bldg B. E.Pressure switches for DPV? Note shows flow and tamper. 9.Add drum drip notation @ EP-7 Column 6 L,owe r Area of garage. Lo.Label risers coming through the floor from the Riser Room. ]-1..Provide correct data sheets for sprinkler heads. l2.Provide correct ai"tg" at node 59, BIdg " n"roQ tevel p1 .13. Provide calculation for equivalent K-factor. Condit j-ons per VFES are: 1. Sl-ow FDC locations, 2. Vertical risers are to be zoned per plan. Fire alarm system must monitor end-o thermals per detect,or in guest rooms for vertical zoning to be apporved. 3. Temporary standpipes are required per UFC. 4. Detail on garag'e ceiling panels must be subnj-tted. Desigrn shall conform to agr' between All State FP and VFE,S -3/O9/O4. 5. Provide physical protection from vehicular damage to drtm drips. 6. All conUrol valves must be readily accessible with out special knowledge or us, 7. Flre hose valves shall be installed at 60 inches above finish floor wiEh 2 L/2 non-pressure restricted valves, NST, with snoot pointed down. 8. Filters and dryers are required on air compressor(s) , 9, Compressors shall be hard wired into a dedicated circuit on the EM panel , 10. Isolation mount s are required for compressor. 11. L,ocate sprinkler heads in center of room where practical but within listing. 12. Stair C 123 does not appear to provide standpipe access to Lower uits on sout. building. Cornpliance with BFPE comnents j-s required- CONDITION OF APPROVALCond:12 j--1ll;]-;--l]-T:?--:T::i:l-llX.-ff--T::--TT.J:-:-T-:.1-i::.::":-:.-":1i-"l.Tli--++***,.*+,ii+,i**.,r*.i..,**,,*i!,,. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is conect. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, Uniform Building Code and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-F'OUR HOT'RS IN ADVA}ICE BY TELEPHONE AT 479-2135 FROM 8:00 AM - 5 PM. SIGNATURE OF O oRco CTOR FOR HIMSELF AND OWNEF 13 . .!?rlnron lfuE 0e :55 FAI 9702451015 Connerclat Desl& d,' XIDDLE CREffi EOor N ct:%ov -TO; -r-InrYemnon, 1rr;I rurrr s I cDE rIurrr s IcDEeA{TDDLE6REEKt_1.:*:::* __ I Frx r.ruMBEn, i uarE a rtrrE' I # PAaEsr I grgl a76 w . -i o6/?eto4e"a3 t^!* 1 24 I .-.l ,FR0/t4: Isgruo€pt I I I*PON SCHANAMAN I nT: I L*_c9rl4Elg/qLqsr6N I I EN6rNEERrN6l I I _l J i ..J AVE. 6RAND JUNCTTON, COLORADO 81501 I -r.e pxor.e, | (e7al 245-0'595 ,AAESSAGE:- -HERE ARE THE FIRE 5TOPIN6 CUT sHEETs ON THE IN5TALLATIONS THAT WE ARE UsINA. IF YOU HAVE ANY QUESTION5 PLEA5E LET ME KNOW, BEST RE6ARDS, DON _ _ rr:_yo_V_qrD r!_oT iEg-EJVE 4[!4€gg c!N-r4crr. I,_ - _| DeN scx4N4&!l- - ..J ,'.!'.'#onrrff Hi.,lrFAr e702rt10r5 -rrrrrro=rilflerclal Desl.o ra1f,'-rglF-ffi '''vroo2 I - qJ FS.ONE l'echnical Sata At rJ'F (23'gl &ld llot rlhtiya numiditv Emt{ocl !-3 !lE!s:b?E4!!I!eutqi!9uE!s09EEnllm.ltl &si!-".!.5@L- conrhd . !&ddnr |irr! !sr.cr'-Atl4!]&--Ct'iln trna Annx. uu..l'319E_cwr A B|rfiGltr$otLlo---.- tlo{Grrrt t saPrhlit, dH_oI, 5*, .. .ffimr!fif fatGliott l4F,ruilzigso:'A-- -Enrnllo.| r.lr (ungbtstsd): [&-c.r-'r{os.r!d|It-Eo!E ..-.-.- forwoaoro ff iEbr8. (cred) 10"r tn ,12"F t:.10'C h 100"(l) Apficrtin l par.lwo .lr.:E lslil!-!.fi:l-ugei surracc brnhl AcrastsrlsUcs (tsfir EE{-Fl Fla.,'!* Sprtd: 0'eilsf[sgsiMS- Sqnd trrtgrlsJon d*glfl cttion (|sru E sJ$l 56 lptrrEE- GBO Ewlorlbn Srftlqr. lnc. !!EI1lEt07l-_- -Cauomb Slrls fi.. lilf's|le I Ugi$r**,qSj!!Ult8___ Gib dt !f rbrl h€ 3r0 gc.nl w. !Y r*rcl rn i:ccocre ullr .tLl179 .ATTU;814 . ASTM E 34 FS-ONE High Performance Intrmescent Firestop serlant hstailalbn Instructlons for FS-OIE ProffidiGr|iilofr. lr[roh$ff,I hc{l& cst €p05al u! fi,t! tirEdqr caaum hlt tdpr prdlct csn[8!bb Jrd rfi.r&Toosltle |tr(n 0!. Umr ft rg to { ls0B tne dhg trodtlEt lb4iltE. $|ci{s, grs uN..taSI ls$hnt rlbr rdrld h|a curut. ccaEln6 rP nebgd|. shPnB o abcko. Htfs tirs iltirg prryfi,g. rt3lrf brisiil.lilgy |0 tjh.| Anar of anelcdol. Srcd, ary ami EhlT |)tlDc. Insulrtod strl and cao',ar d00i. cdrc burdE. Cbsdd or',fftrd 0letic tir3$. llVlC mnelrdlir$ For urc wi0t. donr(|t:, ,rucryry, Urtvdl erd sFcJ lbq tr$lrnuos+ Wd i',(1 ad s*nltllr dtd $ h { h0!! Erampl'3. 5.114) *0lrd 0lr,rtlc i90 p.ruiretlons an fira ntftl dl{ir$ibl. 5€slh0 arflltd rsritlrdblr ad lDn{otnusl;up lcn rnlillfi lr' llr? rdtlt enrdnE|ilt 0p!nio9 'i. C+an fu epBrir,g. ilurftlsr tr $/hlch FS'OI{E lJfll re tfflla't slrll rt bi ,:I.Jrlrd 3t knsn rldlrh. .ltl, flll, r.olr:u!. lrodt Anl iia[ i;lludu,lLl slpurrilr{l tendt',ting itcffi flust |lts ildalled io ccinpllrnoc "Jih irul lrtttr{ng *rl dr*trkd ttamunlr. lgDtlc.llon of itc6toP scoltllt l. k!$t!t ',lP D{e5d't}.id lJgNlllmg rrtrLr,nl ly!$ it:il ftDh it (rlaln thr.i d?slred Btind (l reluricdl. Lro€ eldlicitult drlrh ld( not')l';!.{t Fl.0rl1:. 3. lorlisntio'r of liltib$ sdlltlN: Arrtly fS-CStr l'.t ltr6 r0 iird dq.,ln h nn&( l0 rtli,in lhc da:ftd fitl riliinii. trLll€ crlrc is-Clil dorlDrjl:;1ll ri,dme; la plcvlt, mi$mum adh'?sion Ffi aFl,ti(llllott {1l FiI ONE rlse 'rct lt{ti{d cr!lte4( iirrtl, loil f,ar'..| orm. liuh Urd,ir'il{ txlk iJul vdrti Fs-ol'lt l)u*elN, cnut t4r.t *rdlnnl Jlrrd[s 'ru! h' nfl. iftrrt { n}I rl,1ruli$tttt" f.r naqger $.I(r:tii}li. ,l|. SmcotF:i4 ol lnn..Un .eiirrr:: lc nrtr,i.fB hr Bcrl. ilol imtngdahlt [t {ivo e ! r{ral| 100calalttjr. ErcbrS aErhr . ;iirx l1.r 3dn0. tiltl ')l rlP:r,:d 3'rily iror':l i-ralfinrnl turfuc4t .rlxl tlfil! qi'th lrntfl. 5. LcBtc cocnldtcfl -iei; lrk1is:lnltd hr 1!l hryil5. ii. fof inointonance leoson5, + 0enerr0orl g€al c{r.lld iic oGrrnErl'no, |l€rkcd $llh an rdP;iliiEJtu DL1lP. h $u$ j 0ESE fiDtlr lht idcrtil'rlr{llorr plnle ifd faslen il llr it dglre i)osrtlon nd* to lir,,t s' !. @ctiog. ?. hck t:ii)u;'t ..rrltul ll tilttltanl tbtila $!d.!||!{rlr ' Cltcl tflrt tll6 F uttgfrtn hnt b|g| slrd @rtlil.o D hctne.Jliat rradn! !a lln Rri Bgilclmcd ok!.J.rv u Hilli frreroo tlrlud. l{r lgdlll,. &l$(r', ti[,ng cd rct tflli udrDff 5rrri.s. Rcllr b llilu prootJcl ([drm rri {l- ltc |sriturc4 .lnrjo} ttr srulin djCit3iin d6la r ot f9t |.|.,.. kEh flprr?dL:t lipansrn idr,r. U ffti tlr Or maldlab drri Ol, ptdltlrHt (, !th/e 8 Intt l**d i,r. nrpl{glLlsd l|urt, . bajtd ff,tx, iifcgr fi psrlEllt ?r:V|lt!d ht0c. tr 3i.t 0eeotilsur,utlr g$n g|oco $!qpr& !e!ci!al h hls mrruA 0( n j!6t irfionl lrflu r||a||rtlorE. Erirrc irlsqir4. nnd ttE Fritu;t ,rE f.hla$ m|l 06lr Shgal lcr rdtilrd (65 tnt rrdth Inhrir8lir. l?(Dflndrrndloclllfsn. $br tf.ilbir 0lri/ss r d irlt pnrt$6rl 8lonSe. 8&|t o.rg bfte o4Jiad p*l6ghl in . Eldon lroEdf4 lrtnn mobltro ill rarnp.tiltn ldll'lfiF r0"l- l5"g qtd €S.|- flo"q- otrdati! s{ !dlt? ltik .$ !.to }lsclr$q h,r.*llci |i!li,r:rnid. m |5[ I ?Xrlf,ltrtN'Itrnrl ruln(f :,F 'Irr!!43 l. I trl tsil'll ir.€cl rr(l 'ffiffi f;!kl&lstpndur,nftrnurian: ff" ;,N#;:,:,:,, *.!ffi] ffi m m ffil tn"t"wnrd' Z ['t!, nndrt I ttoAy fgOtn { St dt RLOVf .t urs 4'tf"E A Aitr ni'ft+-viii-tti,,oi'ia ,fli.rtrbtrlol.tu ry&'nrr|||i !!!iD4 r. srqrt RLou 16 |ITlqIJ} Srrirg Uyds thrilgh hflrydiim & tdu$tlrn ! Hilti Firestop Guitc 2003{00{ | l-80dt!}ilIn I f{!iF t,usJfff.cutll " 68/29/01 23.6.m4 TIJE 09:58 FAX 0702{51015 Connerclal Deslg! 1++.' XIDDIA CnEEfL@z@.Hitltia->9?A2451815-t'tcd1@!*t-'lsJvnM @oor 6D rnorr*,itcrs Llloratorics ttlc.'s lb{ttr*.Iffi'Fqn+ffi u*, bf ft. (11612n.6C00 ffi grn gf,hna'taGrt {{fi &snh lrll.b Ffl. I|**q#-FlClEa&lrtr CERTIFICA]TE OF COMPLIANCE CEIffiPlCATtsNUMBETI ISSUE DATE: 21109? - RLl240A Ocr.ober 2l , L99'r Irsucd to: BcFE|i Rcferencc: Thir b to QcrUf that HilEi Construclion ChcnicaLe Inc . 5400 s. l22nd EasE AveBueTulsa, OR 7E146 USA R13240, February L4, L99'l ''Pr6'Gni.uvc rsrnPrcr€'r; 5t*i+"YEE$ 35 FE b:y Ylt!5ttl3;.t?i"E'5E 8F"*i3i HreE bFen tnvcBtgrted try Urdenvrllcrr Laborsroricr lrrc. In accqdlncc rith lhc St|rdatd(tt i;rdbl.cd orr this qcrufi{atc' st rda'dl6l for saJctyl uL, r4?9, glre TegEs o! fhrough - Dsttst rrE lottFirestoPe; vL zo'tg , Tests for Fire Rcej.sEes.ce of guildlng' Joint Svs t eln6 - ?hj:r r,r[i*rtrl i, i,nr Fnrt it,iu[cafcna tr.E iqP,{selttt lt' u.o lx tlr.6u,lh, ?4. l.s aioa | ! rrstop 6y tEada. Ilt+'te sNlnn rr ta. Clrr.ltttg rr "frtJ . !€jd er Crvlty '|da.?!alt ' 8lt trt. Jr Etl.rE :rtrr!ta$' P4.tttt;re ,,, r'6s rqP .f.lda..,rt!r ., rtta.itid in liloD{: of w'. Pir. iatri.r!:.urcc o t r !!ctt'.r. Addl$n lrforrpatlon; Ody thrc produrtc bcrrl4 thc UL Clerstneflon l[rrHnl rhanB tc ooddE|tr{ || Hl corccrl by ULrs cb..lgctdor rt|d Fdltcw.UP acavlcc' rfh. uL Ct sroc:llon MErhlnE Irdudcr. ttE rr.t|r!' 'uD.lcdtrla€re llrbtr Bt r ht': lfr ntd fCLrurdri a cctttol nu[rt$' (rnsy b4 alptl5dslttcrifu .rrrdnF by uL: r rrrr'rricnl lp tr*ttart3 E !4nt of ULf ci.lutlttt ol lhc F.!d'.|f.t; |.tr . lfic prgdqct r:ltcgo.y rE ac (producl klsntllyl tF. lrnlltlttrrl In lhc rpFoFtrdac UL bta*lltt' i r(l}44c(6n4 231 SAVing LiVgS hrcugh innot dion & uducatioft. Hilti tlrc5tse etrlr 2S1. ttili US: l-8(D!?FaxI} / nrri.us.hlltl,aom gft/29/04 rrJE 7:3,8.M4 LAZ0E FAX. 070245101509:57 Hi lti -r""raaqsrSlyerclsl De€lan rca;f,"-tl33lEdcREEff '.* @004 XSDS llo.: Eg Rcv]tlon tlo': 0oS Rrvirion Drie: Wl3,olozPrgr: l dz Prcdust neme: D.tc.ipliqn: Suppli.c Emergency fl (C ham.'l'rec.): F$-ONE Hfgh PEforr ance Intumesaent FirrrtoP SarlaFt one.gart ecrylic- bascd Saalant Hi[i. Inc- P.O- Bsx 21 148. Tvl:a, oK 74l2 ,l t S00 424 g3o0 (uSA, PR, Vigin lslefi&, cEnr6ll0017OA b27 n&7 6lhcr cauntriEEl Pobntctylsto dbplrsisft Calcium cerbonatc Zinc lprute Atnmonium polyphof phate Talc Expar$ablc graphite ElhylcF* glYcol Polybutene l.on oridc Gl6s lllamEnl Silkdn dioride Wlt€r Mi*lure 001317-65-3 138255-88-0 066333-79-9 0148SI.96-6 01z7Tl-e7-6 000107-?1-1 009003.29-6 oo1309-37.1 06tsc7-r7.3 014800-60-7 007732-1S-5 NE s mglm3 ('1") NE NE Z0 mppcf 5 mg/m' (T) NE NE 10 mg/m] NE 0.05 m9/rn3 (T) NE NE r0 mdm: (T) NE NE zmglm" e mOtnl ff, e;100 mgnl (4 fte 5 mlms 5 F€Jmr (Tl 0.r mgnf ff) NE NE NE NE NE NE FTE NE NE NE NE NE NE AbbraviauonF: pEL = OSHA penni59iblc Exposure Limit. TLV = ACGIH ThEshald Limit V.lue- C = Cciling. STEL - Shon i-;art e*eoguie l-imir. NE - Nonc Esdblishco. xe.= Not Applicsblc. (7) indicate!'ca totat duef. (Rl lndi:rtm "ai rlsPirablo tfaction". (At indicstes "49 3n aerosol'. mFPct = million particles per cublc tooi. Rcd pa6re. Not dclarmined. Noi applicable. Nat epplicable. Stab16. Strong acidt, petoxides. and oxidtzing aqenls. TlErmal dccompoEilion rJn yicld CO and CO?' Nanq known- Eyc an t skin conditbnc. .:::::iiiiillli!i J,iii!i;l::!iii' l,i::iiiilii:l " nl ,.:i Wltl not 6ccur- Qdotl€st. a3rnt6r 6t 20G l6sF Nonc. Soldble. Not detsfminod. tirea Involvino 4ti*iiiiilfF, j,.r:,",i, ""' ".. HILTI @ ir a regisbred hrdsmsla of H$i Co.F .OA/25/04 TIIE 09:57 FAI 970245101.5 Connerclal D€sl8! ^+++ IIDDLE CREEf, EbOOS23,E.W L6z@. Hilii ^ ->19?B24S7AL5 - Uca 1u!Am - 25Jun2g6El P.3 - v D€rrnal. IARC clessincs crystalline silha (quarlz sand) as Group I b.E d uPon ?vi.Lnca amorB workBts in indugtrias where th€r8 her beon longFterm and chmnb lxporut! (vb inhshtion) lo r[ica ducti r.9. ctft*q. quarry, stonc crushi4e, rc&acbry brah and potiory *orktrt. Thb ProdLEl does not posc r dusl bazerd; thcrefore. thi8 clca3ificrtion i8 nol 'ohv.nl. Bc€d uPon lhe naturo and inFnded use ol this product, it dDes ml p('38 an ircr*aced cancer rirh to *grhers. ,:,,', lmmediately llush with ptcnty of watef, Cell s pnydcbri if symptofltrr 6ccur. ''.: . lmmcdialrb wipc off malerial arrd waeh with eocp tnd wder. tlilslerbl cen rdhcrc to the skln. ii:ir:ii tf nrrtarff h.3 rdhoGd to the ghin. ueo an abrathrc eofleini?Ef hafr6 ahanet ll md?fisl do'tg ;1,,,1,, not come Oll, butf wilh a pumica Slone- i:r:'i:' Move yir;t.irn l'6 Ircsh rir if disco,nfon dovclopi. Call a phy3iclrn il lympiomr pcrebt, Seek medical anontion- Dg not rnducc vomiting unlcos diredBd by a PhFlci.n. lt a large :.rii,i: quunlity wsr ingeslBd. givg 1 lo 2 glasses of walet b rlllute. Never give anylhing by msuth lo an utlconsciou$ Petson- RcfBrral b a physician is rccommended if thcrc i! lny quclllhn ebout lhe Ecrioranoss ot thG injdryreipoliure. Gcnorgl {natur8l or mcchanically induced frcsh air movemenE). Nol rcquircd, however. safely glasses should bc worn ln 6r6rt ifIduafiEt tsttirlgrt, Avoid skin con(acl. Cloth glovc! 6re Euitable iot hatrd Ffolclbn- Norr normally tequkcd- Wher€ ventilalion is inldoquata to contt€i vapoar. |Jsr 3 NIOSH- aFpfiwcd respirator with organic vapor cai.6gcE. Nevet er or r sonflrrd spaco wlthout tin app|ggrbb :{r-supplicd respirEtor. Storc in a cool. dry arca pfelerably botwcen 40r and 77' F. l(6cp tfom troozlng. Do nol 8brc in dircct runlight. Avoid conbct with fie cyss or Blin. Prlcllca good hygionc: i.c. elwsy8 wasn lhomughly after handling and belote PsdtE or 9molifig. For |trdluEtrbt ura cr{y. KaoF oul of rcrch of childrcn. Follow lebel/use instruclions. tmmadictEly wipc away rpillod matorial boloro it hfidaRc. Placc in r <onlgincr br prpfer disposal in accordarre with all applicable local. stab. or ltalet2l requitom!nt8. fhie MSDS has begn prcpared in ac.cordance wilh thr lcdo.sl OSHA Ha.atd ftmmunlcafion Slandard 29 CFR 1910.12{,0. Hc.llh 1. Flarnmability 0. Reactivity 0, PPE B Not regulaled. Not rEgotsted, Chemical componEnls lisied on TSCA inventory. This pro.luct cantains < 3% elhylenc gtycot ICAS 107-21-l) and q l59t zirc boratc (rc: einc compounds) which ErB subjccl lo reporling un(kr slction 313 of SAFIA Tillo lll (40 CFR Prd t72t Not fcgulaled by EPA as a hazandous wast€. Consult with regulatory agensies or your corpo€ts Fs|EontFl fs di8po€d nrstlF& thd complt with bcal, Blaic. and l8deral safety. heallh and erwirDnmcntal rcgublioo8. Sl.cvc Gcrrard dfti.lfiiltHtpilnfl HariiUi:r:' : : :r:'':r::':: 'iml##lHfiqft iAeiqs Nq'r*, ; -i:Iii: , ,, .,.:':':i l:lii :::i::. : . [S}'ltlvtdHi#,Sta$jsj :' .::.:t.: 'gtr"xllHIi,llllr fict o" 31?i, ,: ef;,*lurlu,coiiltii::,;, 1 800 879 6000 MSDS 259, Page 2 cf2 06/25/01 TUE 09:5E FAX. S702{51015 Counerclal DeElrm O**'xIDDLa cnEEf,Eooe l- fd fssernbly lle I or 2 hr fr? tdod nlbood/dd wdl-ossonbty.. drd h_otrtrrthd d tte mh|itls ctr ntte ,i*'r". +etli*d h br'|'mvidwt t,3(io or Ul{D SeiFid std Futltd| DoCtte h An UL FtE Recl*orrcn tlirctay ind dlol Imlde lh folloning onstructim fc*ms: f" shlla tol lroming drcll cf'*rt of eitfpr rood- gbds or stetl chttnd *dr lood dttdt to codd d nfi Z by + in turter gocod 16 in. lumber sPoc€d 15 in. 0C. $cd dG to bc mh I-\f trr rih o.d +oc?d mox 24 in. 0C. B. Ef6in Bmrd* For t h oncmHy, one iqtr of mh 5/S in. ffilt Spcunboord o_ttsftGd h ht nd,**n Uo[ ond frr,litim D:si0n Fr 2 hr wembly, ho lotilE d rft 5/E ir. tict gtprnbocd os Gquircd in trc indrritfipt fd orrd Portilion 0etri$ llc dffi of-opdtnq l5.h' tr; hnt i totlA * grc fircdop c1ptem is cqudt to the hqrtlt firc rttitg 0a 0t ffil oscmbt h d*n il b i,s'loled. 2. Stcd $ecve (Optirnor) Uor 5 in. dern Sdredule +0 (or frqrtr) sbd. ry dccs ftldjm-ft hto cftq&f opning corc itr{ted tirmtgh rdl. Lcngth of steet de€w t0 be clpd to Sblno$ d 1$: - 3. lil{u,Sh ftnelront fne nom I h, d'om (or sndler) SOR I cros-ftd<td p|;t0rylctte (PEI) ful'tutg for rFs in al6 d (pm5aos or silpf,t) etFag syctcrrc. the trrbing idolhd corwrlticoly or ffcdtbtt.ott .itfn.tlo!. rhrl sfeerye. Ihe orndor$'U[ro ttt. tube ond ttre tfot decYs d'dl b ih 112 h. b mo: I-S/E ln' ftaG to bc dqidl, $fprbd m bdr rldeo ol rdl osscmbly' Ihc hurly T Roting is U2 ed I Hr for I ond 2 tk rol osombh& rtqcc$dt 4. tf, Vdd or Coyig Ud*of-Sdoaf lin s/ts in oN 1-l/1 i'[ rildne$ of fl ndrdsl- qdd rih&t onriulus, flnh r'rtfr Uottt qtf0c89 of roil Ar€mbly tor I ond 2 hr tlted rtf, rupsc$wN' HILII C0flstRuclnil o€rcrrs, Df|, 0F Hm NC - rS4ilE SEom rBeuirg the tf 0ossifrcotiol lhtk Svstem No. W-L-2180 F Rotinqs' - 1 ond 2 Hr (See ltems I ond 4) T Rotirqi - 1f2 ond 1 Hr (See ltems J ond 4) SECIPN A-A Rondnd bt ]l&It kta. Corlrry d' lhdcrrrilru tlbsotci* lr. 0eau 06. &} (o @ C\ d FUl-cF[' FtE fOP S'sIElS n8/29/04 TllE 09:58 FAX 9702451015 Connerclal D€sl& O*"r IIDDIa cREEn [0 ooz System No. F-C-2081 FRotings-1ond2Hr T Rotings - 1 ond 1-1/2Hr A Ore t* -- ItE t d t tr fta-+ded lirqL m€d sld/gytr{F dlbs4 @ rof Jdl bG co6trucbd of tre motlrhls ond in tre mqrnr sp€cifnd in tlre infifrlrd lJJ00 Scdcs fol a$ Fotlilim Oedgnr il Ste UL F'r: Ra*Srrcl Di*$ry ond $oll indud€ $c fo!ilLtg cot$udin hqtrus I Studs -- llom 2 bt 4 h. lurter ;tudr. B. $tc Plote -- l{om 2 8 l in lur$er pbtes' C Top plote -- the doubti top C,qte $roll conqict of ho r19nr 2 Ut + a1. tmlfr d6t13 tfi trn 0f opening is 1'1/z in 0. dtpsl'i' Bg{rd -- ttftlrre*+ !rp. niimbu of hyerc ond 16cur r1p1 bc or +.6r6d h 1gidfiC [oI ord Porttifi DeslEt. J. lLur$-Perutronts - mE mn t tr. ftm crpssfink d Pots{ttyiiffi (PD(} sDn g t.. fuf rne h doscd (pwrs or !ilpplt) fi wrrbd (drin, roste or vent) pphS eyttffns. Oiln d 0f.nh9 S'il{F flodittg ittsn o"C ttrroogt rf ud top flubt of dro6c rdl to bc mu l-1rt2 lr fro t0 bG ttstdt nf90.td on both sidee o{ floor-c?,llitg eemlily. L FX, Ytid a Ccrity lolrbt* -- s€ddlt -- l&r {4 in tlscke$ of fil nrotc$ol egrcd ;illtit tltc onrlus, flu$ rit-h tpp srrrtuoe 0f flofi gnd o mh 1-112 in. thlcffi of fl moffid qpld fitfrt ilr E{tuls, nud} dth the bottput $rfocs of the bp phles. il-lt c0tsTRucllo{ otollc'Als olv tr lfllhl0 - F5-(h8 Sedffit rBochg $e UL Clossificdion llodt ftilldd ry ilT, rte Cfltil d Udqttlt!{s lrSordg,lea h A{'d 11, 203 ,ff, .t6/28/04 TIIE 09:59 FAX 0702451015 Connerclsl Desl8a o*** IIDDTE CnEEr @ooe System No. F-C-2081 FRotings - | ond 2 Hr T Rotings - 1 ond 1-1/2 Hr SECTAN A.A l. Rmr-Ceilirq Assurbly -- Il* | or 2 hr fire-rcted soflrl or burcld ltnter_ F[n floo-r:qq4 osantt $olt be cogstructed ilf fte nrrtcrhb ond h the monn€r specifiod h t\c ttdStidnl lSUl Setls flmr- Cefim Oeshns in the UL Flrc Rqdstonct Dilectoty. tho F Rotkrg of ttc frtrtoP t dm b cqrdl t0 $o rotiry of thi froor-cdirg urd rdl ossembt'tes lhe generol c0nstrudlqr hqttss of $c fioor-caf,ttg orsembF olB ammftEd ffiil: A Fkrs.inq Sptcm -- lmber or dyrood subfloor rith finidt ffoor or lunbcr. ptyrood or Fbor l0?Pttq Sxturer ; 3pccif'ed iR ttre i$lriouot Floor-Cafnq 0eign- Iu &tn of ftoor ofilting h 1-1/2'tr B. f,ood &[eb* - Nom l0 h deep (or deeper) tumber, rtad or cortirtlm hrnltr od lbd i&' truseg or $tudtrd flood Uilb€rBr n'th brUging os rcqu.lrd od rih cttdl f|;#pped- C Funlng Chonndg -- (t{ot Shoffi) -- (As rcqulrco) - Fqlgtt ruoiizd lticl frflit}g fdded h occo*funce rih lhe monrror rpafied in thc lndividuot l-5@ Seri* lhd$t$ h the Frt Rcslstqte Dircctory. D- Gpsuni Bocf -- Ihidmess, t1pe, nunber of bprs ond fosbmn $dl Dr os spedfied h be indnddrtol noof-ceffitg Des'{n mroaet V Hn kt' edtbt d lhd.rrflrr l,lbdruto|les, hc t4.d t1,2OJ ,ff, 16/29/04 TIJE 09r59 FAX 9702451015 Connerclal Dssl8tr O**'ilIDDE cnEffi Ooos l- udl lseoDly -- Ihe I or 2 hr fn-rdsd gypsum rmllboord/std ru oisco$b drol be onsrdd o{tu mslsiols sd in trr monnrr 4*ifid in the indwidr.nl U300 or 1.|100 Siict-ld ond Portlio Dmigs in t|te, UL Frrc Resietonce fircqtory fid shol include ttn folloring cordrucdcr fcoturest stu& -- uoll frwn'ng moy comfid of eiilrer rood stlde o? decl dronncf sbG ftod cfu& b ronsist of nm 2 by 4 h. lunscr spoced l0 in. 0c. stcd cuds b bc trfii 2-llz in. Iih ond qocFd mor 24 'r'i. CC. tlm stoct studs ore used ond the dicn d oparru odre trc rittr ofttd covity, he opada shol bc fioned on oll sijcs usirp lcnqths d shcl st'rd ildokd bctrcen thevcrtid stl* ord w*-drdrcrt to tre deel sttl6 of ooch 6.d. Thc fiffird oofiim irF thc |d[ dtoil h 4 to 6 in. xidor qnd- a tg 6 h. h'4her thon the don of th pntoolhi nui r*tr mq rhan. tg Ellchotrts item ir instoilcd in the cpentnq o 2 to J h cbdqn ir irant bchrocil lhe penctruting iten ond the ftorring on sll four sidee U^tp,ryl Boo.d: --. f/a in.Ur-Iiq +.ft iide.yqh $uo!e or-topered_ edgcs. TE Spqrn bood t1pe, wcxnefs, DuDDer ol bJE s, lostcner type ond $€d orienhtin shol bc o' tpccilied irl lhc indridrrol U300 or U4fl) Seriao Deeign ln the UL tirr Rcsistoncc Dmroctort llor dian of opcr*rg 'E JZ-1/1 'n. lor steel stud rolh llox dom of opening E 14-l/2 in. for mod dud mls. lhc F Rotiq of the frestop sFtcfn is €$0t to the firo roting of thc rd oseirdy, System No. lf-L-f054 F ffitS - t dnd 2 }k (9Ghrr 1 cd 3) TMlng-0ll t hffrg lt ffi - t ss lht t Cn{/tq R LSdhsAamF-1Cfl/tqR sltot hA ftlludlc€d by |ttLll, bc. Cajrt?ly ol U[drrHtalE Loboro toriE. lnc. 0*.ntb.r 1, 2m2 .tr" .06/29/04 TIIE 09:59 FAX 9702451015 Contrerclsl Desltq +++ XIDDIS CREEE @oro Systern No. f1-L-1054 F RotuF - 1 ord 2 Hr (Sec frm I 0d t) TtuUng-0ff t kthg A ffi - klr lhm I CFIAq R t Rdirg a {n F - 1ffIAq R z thrqrg+$€trglts -- One metolfr pip,e, conduil a tubing to be iruhd alha concarttcnl; or t*pFryl[ r.:*hh try n]eslo'p eyrhn. ffte_onnutor spoce shoil b nr'n 0 tn to mor 2-ll4 i. frW nsl F fqghg rilh conlinuow pint. contocl. Pipe, condrrit or tuburg rrly !c imlokd d on ingc *t *t;uron $ d1"g.from ppadft:rlc. Pirc. conduit c'r tubing to br dgidly aryportd m both -*lcs c rota$fl'0l1 lhe fohuhg types od sires of meiofrc phes, iondfis r tdtfrg'tmy be ced: I Stoel frpe -- llqm J0 in dom (or smollcr] Scheduh t0 (or tmrlor) dcot pipo' B. hon Pge -- trm 30 irr. drom (or molfer) cost or duc{lc iton pipa C. Cmduit -- llom 4 in dhn (or snuller) steol cloctdcol rt'Gbfic ilft'S or 6 h. rftrn 513cl confuit D. 0Qp€r TrStrS -- tbflr 6 ilr. dom (or yrnkr) Type t (or heol{cr) c4pa tu*q. E Copper Pp€ -- t{otn 6 in diom (or smolbr) regutor (or luobr) oopper gge t, lll, void or Gcvity Motrldr -- sedmt -- Ilin ilB in. trichsr 0f ftt [frt€riot rypf,cd t'trin urc onruhr, lluft rith hth surfoe of rcll. A the pint or continuurs ontod bcotoni'b.fnen pqDe.rd l$ q "dn 112 w {si b.d d fiI rrolsiol sholt b* opptid at tti pf6 rdt ilbricc on bAh stftcceof roll , ilLll m{$RuclloN ftEttctts, uv tr tlLI lt{C -- FS-0ne $olsntr8corhg tha t[- Oossificotlon Uort f,|9rcdlced !t HIJL hc, Cortary Oa(hd.nritcrE hbomtsrieo, tnc, oec.db.r 4. 2002 ,ffi." N/29/04 T{JE 09:50 FA.X 9702451015 Connerclal Dssltn +++ IIDDLE CREffi @ orr SYstem No. W-L-2098Ftuhos-lord2lf(S;lhml) T Rrt6 - | ord 2 tl (* h;r t' L Rdq fr finbint - toss thcr I GtIISq R LFffirgAt{00F-I r^ l--r 1. l{dl ArsunHy -- Jhe fire-roffi gpsum wollboori/stud rdl osccmb| shdl bc onrbrrtcd d tho nuteriqls orrd in the monner specifird in the indivirJuol U300 or U100 ffi tfdl std Potdt'ton ffins ln lhe UL flre RedgtEne 0ircctory ond Eholl incftr& the folbring constudftn footrrccl A Studs -- ffit frqn'lrg nroy cotuitt of eittilr r00d sMs or dd ffi d6, f,cd tM3 to cofrc'rst of mn 2 bt t h- Unb3r spoced 16 in.0C.51cd sb6 to be nh2-1/2 h $dc od +ftd no( 2+ h 0C. B. Qpom Bosdr -- 5/E in hiclc 4 lt rih rith squce or hppcnd cdge+ Il|t gtFm mltoad tp* ticknesc, nurrber d layens, foshner tpe ond shed odcf*d&n dnl be or rgedftd h tlr irdiriduol ulol ond Fortfthn llcsign. lkn dhm of openiry b thc hourtf F ond T Ro$ttp of trc fktstop ryhrl ore equol to thc $iDh it b lrtolled. 2. lkor$ Pcnelrsnts -- One nmmstollc pipe irnhlted sithin tltc fircdq ryststt npc b h dddt sryportd on bolh sidcs sf fuor or roll ossembly. lhe sPoce bdmen fp ond FIdErt of opcittg #l be mh V+ in. to mor 1-l/4 in. Pipc to bc dguly suppottcd on bo'0r drhs of ttn lhor or mll cembty. the lollouing tyFs md aizes of nonrnetollic pipes moy !c tstd A Pollht Chlailc (Ptrt) Prpc -- lhm 2 in. diom (or mdler) Schdub 10 Plt phn for $s in cbsed (process or suppt) piperg sylten B. Chlorinted Pol! frt, O{sidi (ctl,c) P,p, -- Nom 2 irr. drn (r xnolcr) Sl7 CPVC t*pc fo uge h Uosad (pocrss or srpP|) ppins sl6tcflE. 3. ru V$ or Oority Uotsidsl -- Sndqnt -- Instdled to comgl{dt fll tlt omdor rye bctrton the Ffip€s fltd grpcufitt rdbffid on both sidcs of mll. HX-n CO{SIRUCIff fiElflcAs, mV 0F HtIl lrt0 -- FS-0ne Seghnt rBcodng the UL Clossificotion llo* 1-v8 ltouil it fin ru6r4 of fit rd o$eilnb} h [ilI=ffi'HHn 5r5f$ ktroduc€d b H[n hc. ColrLt d UndsrrrltiF l-oborotori.r, lr1a Jduoty 09, ztrl sffnor H 08/29/04 TUE 10:01 FA-X 9?02451016 Connerclal Deslto +++ UIDDI,E CNEEK @ors System No. F-C-2127 Ro|hg - 1 ard 2 tlr (SGa ftcm l) T noUng - 5/4 ltlO t-ll+ jF l. Flo6-{tO lffil| Ih. I fi I hr fire-roted solid or iru$ed lunbd itbt -froor-oaTng e*nbly $d be cordnrc{ed o[Su mdirlis ond in lhe nronner specifted in the indrridd L500 Scdtt Floor{e$ng Oei$s'trt tE {JL F*t Resitrne Dlrrctory.I! F fuftg d tilHop rphnt b cqud b ||: tfr! d l|r loott+-tg ci d {iltth. Ttc Ancrol congtruction lestrrres of the floor*eiling $sembry orc rumofted bck f, Fhf g&n Lumber of pftmd subfloor rilfi finFft floor of lu,nbcr, pSrod or fbor Tqdng Std og ipedfred ir' ttr individud Fbor-Ceilit{ lbsign. [0r dom of floor opsthg 'u 5-l/2 in B. ftod Jolilf Nom 10 ir4. d.cp (r de+er) lumhr, stecl or oqnbMion hber ond dcd ioi$, hnccs or Shdd fod h$r* rith hidgiq oc requked ord rith endr firudoped C. tmg CIhrnds (ttot Strorn) -- fusilent golv eted funing hehllad p€n€ndcub to rood iobb bctreen rdbmrd ond rood joish os rquired in the individuol Floor-Cefrq Desfgt Ffiitg chuutds spomd mor 14 h. 0c. D. ryDagn hrrf tlom 4 fl frJe by 5A in. thick os specified in tfic idrldnl floor.Calng hign Udbootd srcrir,fu to mod joints or fuirfng chonnols os rpecified in Ur€ indflidwl fbr"Ccfitlg Drdgn Reroduftd by lltll, Inc. ContGy dt derrdten tobotnttries kEa Juh 18, 2002 .tr" AE/20/04 nJE 10:01 FAX 0702451015 CoDnerclal DeElEn +++ IIXTXTI.B CnEEf @oro F ketg - T Rdhg System 1{o. F-C-2127 1 ard 2 Hr (sac ltcn l) - 5/+ fi{o 1-3l1tt. Z CtD H lhe trrouqh penelmnt (ltem J) sholl be rotd thmugh o 1 or 2 lr fry-rotd !in{h, douHe or doggorud wd shd/$pffm wtbood drc r{tr con&rntd of ttr rnoteridc dd h he m.ilr ry€etrted lo thc rnirilr lpcdrd h tt* 'rdviduol U500 Series Sol ond Portitiqn Deslns in he U. Fire foidoncc Dil€cfory crd ff irtcldc thr fololhg eendruction fedurca; A StS llom 2 by 6 in. lutnber dtds B. $h Htr t'lom 2 by 6 in. hmbs plohe C. h Efr Ih dqlrte top phte dtol cdrist of tuo mm 2 by 6 it lmba pHca llq dom d opc,*tg 'u J-112'ri. D. q'FE bcf, Tft*srccc tlpq oumber of hyers ond fostnaB droll bE or spedfiod in indviltrl ftl crd Podltixt l)edqP I llmrottc Pcrffi 0rr nonmetqfrc pipe to k instolled either cfficsntddly or ece|tfc$ ffih fftc tiltitop aFtcfir lhc onnulor cpocc betrren pipe ond p€rUEry of opening rhdl be conliruous osrtEd, 0 h. (toint oonfuct) b ru X 'ilrt. or 0 lu (pint cortoct) to mdc I in. (Soe ltem a). trrp to b ilgi{t nmodcd on Dolh crhs of flE fbor-cifing orsanbly. nrc fofio$ng typrs std sires of nonmetollic penefuwt moy be usd A. tb|*Ul qfsidr f!rc) h ilorn 4 in diom (or ernoller) Sdr:dub $ mld cm pft plr h rna in cload (foces$ u $pf) 0r varbd {ffin, rusb or vant} fiping ryrton* & f,lshftd hfthlf Orh/* (Cnq ft. Non 4 'n. diom (or $nolr) SDR115 CPVC 1f;r fs rnd h domd {procees or supply) p$ing systems. C. Arfiorftf Brhfqrc $vnr (iss) ftn Nom 4 in. diom (or mclcr) Sdndule {0 cetob oc fBS iF ftr re h cbaeC (process or supp$ r EdEd (dmin, roste or vent) piphg qddffi. {. Ff kid c Ocft ldilfd+ -- Scolail lifm 5/4 in. thicknes of fll motedd opplrd ritrh ttu orulur m bp ardoce d ltoor or sola plote of drce rolt llh y1 in tllckness ol fil moFhl Epliod rilti't Oc snnuls d t]rc bp pldr ftfi Wr 0re bottonr arfoe of tte liler top phte, Ilin 1/2 beod ol fill fltrtcthl g/id ot tte pstcbrf/ phtc hhrfsces ot poirt ccntoct locoticnrs on bo{lr riles of ossembly. lfhen prnctmnb orr f$hd d oontiruqr contod or rdn 0 in. to mqr l{ in. onnulor spoc€q o I in ueod rhqll be oppfred 0t thc patetrmt/ptr intaloca qtd ottr t( in. onndor ryoca m bo0t sides d 0|e ffinb}. lllr cs6rfrElt0r{ ffis lll, tr nn lG -- FS -- Ot{E Scoht* tfroritq hc UL Chs:ifbotion thrk niprod{cd bt Hlul Inc. Coudtsl ol u.diff,ihr! l-obomlodrs lltc.o Jdt r8, 2002 ,"ff" FIRESTOP SYSTEMS ProSet Systems, fnc. f a55 e.epltalClrde Lawrencevllle, GA" 300436866 U.S-A" Design No. PSTPH 180-03 Hodzontal(Floor) See ltem l. Rafings: ASTM E€14 - 3 Hls. (F),2 Hrc.. (I) CAI{/ULGSI1S - 3 Hrs. (F/FH),2 Hm. (FT/FTH) Test Prassure Dlfierential - 50 Pa (020In. of Water) Minimum l. Floon Mlnlmum 7 thick normal denslty concrete slab. 2 Plpe Support support for the riser pipe is prwlded by connecting the plpe b the fiesbp device. 3. Plpe ilaterlal: Gastlron, maximum dlameter3 in- 4. Flreabp Syctem Componentr: tfa. PrcSet 3' FVC Tee or Gross & Mounling Flange'cas{ ln ptaoe tn tre concreb equal b he stab thidatess. &andres conned only b dosed end frdrres. 4b. PrcSet 3' Gast{ron liner ppe insert, Part No. Cp35953 4c. Prose{ 3' E-Z NeHub Adaptor M.J. Coupling, Part No. S3S4ZO I Cor4ponents Bearlng the lVarnock Hersey lntemsilonal Certfrcaton Mark IRESTOP SYSTE ProSet Svstems. Inc.1355 Capihl Clrcle l-awren'cevine. CA aOO+li-1A66 Design No. pS/pHV 120-04 Horizontd (Ftmr) Verticat (wa[) €ee ibm l. ._"^ft iii8llfJiEfii;,tffi f ?'fr 3?'[F,,,,Test pressure Difrrential -z.spa(o.oi'in. dw;t;l) iliriimum o 1. :t_ooR: I't ;rimum +112' t1i*'.1orm1l 9"F tv concrete slab or 7-ll2'thic* hollorcore precast conc6tef - 'r units. Fluted decks witr 2-rp'concrete srab, rating rs rii #mi-\,'ALL: lt iimum 6'thick normal density concreb stab.)I ,re l\rlaterials & pipe Support:\ -nted or unvented pipinf_CeVdoi, pVC Scfr. 40 or hrbir,r {mum diameter 7 lnrOevtecan t*-,t_-.iJr"ir-.o-'l€e or unvenreo Dnng_cpvc or pVC Scfr. 40 or hrbing rrall thlclmesCIl :,ly*i"T.:g llllo"Ifcan q uipdniiwasrc prpe.I e tical riser support br pass trrougri Fbe is "rijpli#i'fi'f,t ftosea ptug nrastop devtca. plpB. 3. .:' :stop System Components: ; ;lroqe! Qerieg # 43 Sleeve Couollno. 1 . proset seat Rinqbi coreo trol-diii-eve and (optionet) pqsqtwabrproofing Gautk ps 3s.I -oset pmseat Ptug insrait;it at t6p dijti,,r u,arr!. im-Frta-nt Foir Fqp "nqp b.t a;X"rT$pl5?^gT*TffirtBf8 , ressure pipe at the point of contad arouno ne Frosdtpj,Eio;;"ont arry mtgrauon. ' lJr . Rating for vented pipe is I Hr. '-q Qglelt Bearing the Wamock Hersev lntemational cerffinatian Marll Gertification Mark RESTOP SYSTEM t- I ProSet Svstems. lnc. 1355 Capihl ClrclE Lawran-ceville, G4300436866 U.S-A" Design No. PS/PH 120-06 Horizontal (Floor) Ratings: ASTM E{14 - 2 Hrs. (F). 2 Hrs. ff}cAwULesllS-2 Hrs. (F/Fil.2 tirs. FT/Fft-t) Test Pressure Diftrenttat - 50 p'a (0J0 in. of Water) Minimum 1. Fioor/Ceiling Assembly: o'e+our rated or twohour nated wood framed/grypsum wallboad lfoor/ceiling assembly. F, : ' H raling ls limited to trat of he lloor/celllng a-sibmbf. l. f ie Materials & Pipe Support: |.r.ximum 2' diamebr Sch. 40 ABS or Ceilutar core FVC Branch pipe supported by solvent cementing tap to coupllng. 3. Firestop Sptem Components: 3a. Fire rated F/C Tub Box': n:oseat Maptor plug. - p25661 fur pipe slzs or p2s662 for Tublng slze. 4. T ' or Shower Fittings:.i ^ rass or plastic fub drain orerfiow fittinos orq ' PVC pipe extenton up Into a precasfshorer draln Jolnt 'corronent Bearing the wamock Hersey lntemationat ceffication Mark FIRESTOP SYSTEMS ' ProSet Svstems. lnc. 1 355 Capital Clrcle LavnentevillE, GA 3d)43{866 Desig n No. PS/PH 12047 Horizontal (Floor) 1. 2. 3. 4. 5. Flcor: lrlinimum 4" thick normal density concrete slab. Fipe Support: Pipe supported by sofuent cementing the fap extenslon or pipe b sleew coupflng. Pi;re Materials:j 35 or cellular cora F/C Pass.Through Pipe (Stacks), ma:dmum dlamebr 4' (not shown). P--l-rap: I.BS or FV_C, maximum diameter 4' (sho,vn). fi,:stop I ' - " DroSet System Gomponents: t PVC Couolino'. castih-olr Ratings: A.STM E€14 - 2 Hrs. (F),0 Hrs. ff) CAI\UULGS115 - 2 Hrs. (F/FH), 2 Hrs. FI/FfH) Test Pressure Differential - 50 Pa (0J0 in. of Wster) Mlnimum - f,roSet PVC Couolino'. castir . ) roset Setf€eal'lnfu-m-escent r r:n Cnr Or aira a ..--- a^- t. castih-place. scent Wrao Stsips'. I'or 3' pipe & 3 wraps for a 4' pipe..'ap for t pipa, 2 wraps for 3' pipe & 3 wraps for a 4' f loor Drain or Shorrrir Drain Asiemblv (shiryn). Proset Self Seal Mountino Flanoe'- I E I .rap for? Seal Mounting Flange'.-9. rponent Bearing the FIRESTOP SYSTEMS ProSet Systems, Inc. 1355 Gapital CIde l€ryrencavttte GA" 300t3€866 U.S_A" Design No. PS/PHV 120-01 Horizontal (Floor), Verdcal (WalD Ra.!ngg: |STM E€14 - 2 Hrs. (F), t5 Mtn. (t) CAllruLC^Sl15 -2 Hrs. (F/FH), 15 Min. (FT/Fftt) Test Fressure Dlfferential - 50 Pa (020 ln. of Wat60 Minimum l' r:mum +1F2' thi*' normal density concrete slab or 7-1l? thlck holtorvcora precast concreteL r'units. WALI-: Minimum 6" hick normal density concrete orany dassified srcreta block 3. Pipe Materlal & Plpe Support: Ca.-tiron, maximum diamebr4 in. ^ V.e iical rlser pipe ls supported by connecting tre pipe b the f,msbp devlce.3. Firestop Sletem Gomponents. : ^. proset PVC coupllng', castJnalace, or cored Hole Goupllng., lengrtfi equal b stEb ess. Optional wabrproofing caulk may be used undersaal rlng.. ncset EZ Flex PVC Goupling'solventwelded inb bp and borcm of coupllng. -q : PVC lnse( Sctr.40 pipe, solventwelded into coupling. ^omponents Bearlng the Wamock Herrcy tntErndtonal Cerllfraar0on ilart. FIRESTOP SYSTEMS ProSet Systems, Inc. 1355 CapltalCircle LavnenceMtte, GA 300436866 U.S-A" Design No. PS/PH 12U14 Hodzontal (Floor) - See ibm l. - Raflng9:ASTM EA14-z Ho.(F), 2 Hls. (I) CAI{/ULGSI15 - 2 Hrs. (F/FH), 2 Hrs. (FI/FTH) Test PressurB Dtfferentat - S0 pa (0.20 in. of Waffl Minimum 1. Floon Mlrlmum 2-112'@nc'eb slab, poured on madmum 2. comryatad m6l fiuhs. 2. Plpe llaterlal and plpe SupporE I'iaxjmum 4r ABS. cellular corc PVC or F.R. P-P, Support at penffiirn by sohnnt cemer16ngthe pass through pipe b the embedded pVC slerivi-65uiiini6;e.-" 3. Flr€stop Devlce: t 3:. casun -Part numbers-P2549H€', 2' p3549H€. 3. and p4549l{g, 4..:'.. Adjustable 26 gauge^s_heet metd insert cottarwih teOry Urm.in intmescent' zp with maximum ? collar odension to he botbm of 0re metal cor rthdns. :rmponentl Bearlrry the warnock Heraey InternEuonal carullcdon tart. a FIRESTOP SYSTEMS ProSet Systems, Inc. 1 355 Capilal Clrda Lawrencerille, GA. 3d1496866 U.S-A" Design No. PS/PH 120-13 Horizontal (Floofl - See ltem t. Ratings: ASTM E€14 - 2 Hrs. & 3 Hrs. (F), 2 Hrs. CD Soo ftem i. CANruLGSl15 -2 Hrs. & 3 Hn. (F/FH),2 Hrs. (FT/FTtt) See itam I Test Prssura Dlfrrcnlid - 5{l Pa (020 in. of Wabfl Minimum 1. Flmn fllnimum 4]giclq noqnal d.engity.ggncrete stab qr 7-1./? glg.helgrcore precast concratefioor units. Fluted decks wttl 2-1lt concrete sllali, radns Is l HiFiFii-- - When concrete or hollow core ls T 1lZ' or moreh-e FflFfi rmng b:3 Hts. 2. Plpe llaterlal and Plpe SupporE 3' or 4' Cast lron or Copper DWV. - Closet or l/4 bend can be s.rpporbd by the flrestop davlce. 3. Flrestop Davlce: 3a. Castln Part numbers P38l4H', t'sn6l pffi{{}f, {.. 3b. lnsertad in cored hole fart numbers P3S54Hr,3'and p4iS4H.,4,. 3c Adaptor Flex Coupllng fart numbers R15470,'3. andp4f!'m,+. Water Cloest (Not Shown) Flocr mounted doset mountb doset flange. 'Components Bearlng thg Wamock Hemoy lntemaUonal Certlllcdon l|art. 2004o FIBESTOP SYSTEMS ( polyethylene (PEX) SDR 9 tube for use in closed (process or supplv) orvented (drain, waste or vmt) piping systems. pex'tube to Ue ."'nieieayr* gpen{g wrrh a nom annular space between tube and periphery ol opening of 1/8 in. Tube ro be rigidiy supported on both siles irfroor-ceunq assembLv 4. Fill, Void or Cavity i\,Iaterialsr - Sealant - Min 3/4 in. thickness ofsealant applied within arurujar spacc, flush with top surfacc oi nnor. o, sole plate. Min.3/4 in. thickness oI sealant applied'within amular or vented (drain, wisie or vent) piping sys- space fl-ush with bottom surface of top platei System No. F-C-2203 FRatins-1Hr, T Rating-- 1/2 Hr Chloride (CPVC) pipe -13.5 CPVC pipe lor use in ne Stl,rene (ABS) Pipe- Nom 3 in. diam{u sotrd or cellular core ABS pipe lor use insupply) or vented (drain, waste 6ivent) piping shown) - Nogr 2 in. diam (or smaller) non-connection.with bra_nch pipe, p-bap to be ofiallic pipe used lor branch piiine. Materials* - Sealant - Miir 3/4"in. thickness oI Ipannutar space around perimeter of throueh pcn_ . with top surface of {looior sole plate aad ilm}ral top plate, Min 3/4 in. thickness of sealant spacc-around perimeter of branch piping (ltem e of floor, Min I /2 diam bead "pohell ai tt "rnterface ard the pipe/top plate' interface at 26 Mark System No. F-C-2202 FRatinq-1Hr TRatinE-1Hr SECTION A-A tl - tl" I hr fire rated wood truss or combinationI truss ftoor-ceiling assembly shall be constructed of tm the manner described in the individual L500 seriesin the uL Fire Resistance Directory and shall i construction featu.res; FrBE RESTSTANCE DTRECTORY o solid or cellular core. ABS pipe for use in,) or vented (drairl waste or'vent) piping c pipes may be used:Pipe- Nom 3 in, diam (or smaller) r core PVC pipe for use in closed Nom 3 in. closed (process THFOUGH:PENETRAT{oNFIRESToPSYSTEMS(xHEz). 2629 LOOK FOR THE UL MARK ON PRODUCT c6/ 2v/s4 'r'uE l6 i 45 I'AI 9702451015 +-'+ IJDDLE CREEI(@oozConnerclal De8ltn t. lgo. -- ftillng Aoornbty lhe t hr firc-rotcd rotid or truscd lumbrjrist floor-ceilirg ossembly slrcI bc constrwted of ile nuteriob ond in ltc..m5"g sqSllnd h th kdddsd tS00 Sdi€c ttoor4rflhg DGigch hdn- Firc R*irhnce Dircday. lhe generol corstnrction feqUres d the floor-cdling oscnrbly re gunmodzcd belou A .nooing Sptem Llmber or flyrmd suMoor jth finish floor of lur$or, plyiood or Floc lopping lirturef c specifki in the hdriduol flmr-Caihg Dedgn. fiectorgtdor otoirt in floorlng to occommodote the hthtub dmln ppr"ng (ttcm 2) to bs mor g in. W t2 in. Cutout to be potchcd on urrdcrsi& it suOmor ufrq onc hyr of nrfrn /a in. thhk ptymod or min S/g in. thhk gpsum boord (tcm tQ sLul tD lq r*r 2 h. bcyond cch cdgi of rectonguhr cutoul Potdt splt inb tro dres ol opmlng ondlolc*orcd for bo{rtub *oin fi;ing. 0[om of Acrfng'holc -srled throql potdr to occonrnodstc droin pipinq (ltem 2) to be I itn. lorga thm o{tuidc &m of &oh pdliA ond posilbnd guch thdhe onnulo epoco betleon euh piphg ond pen[hsy ol opcrirg ia min 0 in. (pht contod) to ru I in. Tro dects positiond orund droin pipirg, rfth cut cdgcs ttighfly buttd, oril scni-sttochd to uderddo of sl$fltor rfth l-lfi in long steel soers epooed mor 6 h. 0c. 8. $md Jobb. tldn l0 irr. dccp (or Occpcr) tu*er, s.tcel or combinotlot lwnbcr ond stcel pists, trusees or Slructurol Wood Ucmborsr iith brldgns os ruquird od $th dr& frestqped. C. Glpsrn Bood* lbil 5/E'iln hit 4 ft rkh os rpccfrcO fr Uc irdividuol Floor-&*llng De{n. System No. F-C-22O+ Ftuthg-lth T Rotng - 1/2 Hr o o L--------_-_____J o a R.F€*|od !r HlJ|. hc. eatk't 4 Undcrfurs l-otaotod.s. lnc 0*anbcr 7, 2001 w/2s/01 ruE 16:45 FAI 9702451015 Correrclal De8lp @oo3 $7stem lto. F-C-2201 FRding-llh T Rotrtg - l/zlh 2. Ddr'Pfing |lon .1-l/2 in. (or rmoler) dom Sdrcdub l0 ooylonibile butodienc dtren (ABS) or pgvirryt drbi& (h,C) ppe ond &oir+ filtimr g.dlrtnted togehcr old profthd $tr lS or pli0 IoOUU rosfcTovcrffor ftlingr. Arnrhr 3pocc $olt h nin 0 il. (goht oriod) to mor I iaI fll.Ydg or Cotdty [${d.: lin 5/s in. iepur or m motena oppricdrithin the onnulus, flush r'rtr boh surfocee df Srmod or gperrrr'loort potch. HLn CO{SlRUCnoil OAflCl|-S. Dw 0Fmn fS -- f5-,Oif, Scohntr&oring thc UL Oessilpqtlon lqrt R4mdro.d bt Hffi, hc. Cortcst cf t dlrrrltc|! Lobcotodcr. lnc. Occmba 7, 2llll + + oo I'i i:ltl rM"+a i'iinJ I -r-1 | tri \lr E5 e.Bo FFF g 3:g tss ses+ <tE a sitr'+xl Fl !l I I + Rili 's =llFlizl t'1 t4. l__nt= -_D >- I cz. z.c< L/a + -t oo lrEIE!N iiiE sFii tl 3 E 5H e. :1 (r F*F s A:' F13- ei SB3d -+ f,lsl =-lsl "l + c =lrr =l[Flezl t"1-l t- I I -t-rtr-IO t: ta-->z I =z.c =CDrfl <t) + + oo l(r)t><l.--l It-1ta-lo l- l>-, I Cz. z. <CF ET <-/'> E= 9.3<D F*s g g:B Eq ag #a6(! :I ElFlf;l E =lllEl! lEl-lz ttl + + oo tLnll'?'lt6t= t- t= t-_E) Fz, I -. =. = -ttJ) 5E e- :1 tl FFn sq:9 B6 sg3S F'D + HI Fl I + ailE 's rll !lHzl + + oo tFr-r | -t- I- t=lo -D >- I z. z,c< rrl 65 P.3(D FFg g *=a Fss UtF-t,*i $#s o.:6. cO,i€r: CO i:O Cooco:io. J_rl I\5 q() :-F*l J ::,,,,,::: c:i.:(f: -t, r:S: E i,.s' 3I .9. c- -r::E::: I< 'o: oit :" !ti!- '.,'.,: :liil ,.':, ::!:|:l:::: .:..: ..r tO .-t. -ra O: (' 5:r,::P I 8,;,$; gl <,ocno-+c)I 9',,9,oo: oooo :',t,:',::',: ,:*I, :::EB: ',,:fl).i,.,:o.:@ {o,ooo (,:::tOot(oP.F o:6 -n ::-n c ..F @,(D :::,:,::,: .A:::]!.: 9,69.+ @ t:i!:-::..o6::S ot'€i,,('i .,:jt::::: r :i*::::i| (, ^s{o.lrA o, (o(r)'i*+ st!o,6.o. tl- J$;o)oo5:(o Or'btioo -n i :"n: c:q. o- ,6:r \.>rb& t: oo<5$C)5 :|:r*t OJ ,+ -{og 3o 6ooo -.1 .:. O.:o:: o:::o.., (o::i ito, oo --'1 ots.o tD o} 3!) =o!F} :'::' 5 OJo + o! N.)oo5 @ o);\o @ :,{O :t.::'!li: ('.:.to 'n,,:i:ni c.::F o ,|}:: o (J:5 :*+: (,o bo -.t {o. ot CD :'<',: brr;i5:o':tlc': :,:.,r., o,,:,iidr :' 't:g'o (:':c) o: -n.. trC::C, d r.-a---i :,::::: b:,:b5rs ::.:::.': o.45<, fr- --.|' :.::.!;*l O::i5(,ri:,.(f!: {;i o..c:b:':t o,,ttF -co . ': :: J::':ir'!F oc ., 'tl:::.'f C:::Gd ::d :r:li.:l i.;'H b:::6$.& ,:::' ::::::: o'r.r CD :::(.tj !(lJ: o..cr(,t (Jt- l::i:|:t: JN' o:<)55 (o 1o (r)(t ?(l) co C'I(n (o '!o o)(o ?(r)o(tl (Jr (o (o:--l *l:o...o (o :t;ar: '\,.:J.llo) \l: Ctl r:,'A: or .(to. :o).6:t\t:]:]:':' @ i:,&I: -{!;i:lEl: O l,:,(i' (,) ..(o @ ..<r) A.:::+4, J...(}i.S r+.\.lll:@: @:!g: (O:, ,.1 ,,: , (O.\.1 ": ::: !o,::r:::os.: ..4-.1 .:.. \ro) :.:. o) (Jrl:.:::. : :r -..1o, ::::::: @.r:.1 -r':: : :i: :l:::i::: o @ or.: :\r. o:@::: (D: ('|: N,(o o)o. ..r 6:r'',',1 (i,,,'',,,o o....O): O.(c) ,O :r,'! .l -nc a o5 (t o(rl JJoo(t (rt; ottr(':ri(,t: o.655,! ,:+:'.rii a:'5: (o 1o (1)--l o,I(o (o ?@N coN(l) :::IE': ::+J.:::c': Aill .,,!:: "<:.{..5 l.' 1.8l.Atco l3to Il8t\ l3.rlo,IA o(,) o oo (r, 9.o e. ; o!' P(too ooooo(tl ctl c) or-' (D: d l'6)oN) oooo oo Pa)o(Jt €o o -@ o-7 CLo P oN o oo (,| (D I o6o o a ='o 4o \I G' :,o -.t(,) oo .{(, oo \t(t bo (rloIo<) -Il c d {(t bo ('r aofoo 6 A oooo -n c d (rlo N:. O!,:A. (n .!. O:rr(t ;,: '.,.;I R :': :]::] ,,:t. :] .' .iro o (,lo5 (o\. (t(, d, C.)(o N 5 No :.16 C,Jclt G,A'{l' --roo :AAiil {o, (o ]NI (':!i N(t (rlEN ^:iil{: ^{::rltli Gt (o:.9, !gA :iar' CO(o<6! 9'rP tsN .ltr: ?\)co a. o)S, Or, CD(Jr:r:j6: or ooo o6 C)ooc)or ct ool (D o6 oooo O) I Io !oIoo o ._l Cr, bo \(t ct {o) b o)(rl9:O:ol 'n d (o..1 A o) ('l(rloo o:'6:5!, J,, GDQ:b,('j:lO: d:.tso... olcn ... . i.: J :,, ;;f oct55 :,1. ':::i:: (o: A..1 o) (O, ::: .!:;:::l{',,,',:,, j:::::':]:'' (O:::,.(l-{.:oto::o N..:(E.o):.:.ltt-r i(t: o !:r:rit: o):'rh)o) ::(D. (o--to A.-l(oI@(o 6 N o)NN o) N) o oo(t\ + I (\l l(\l f\ Fofrf; ?i'so.ttfi) {fFili- $R'd Ifi Y Et t7: F4 + oo f E sF g.ao sgs g A:F FS BEse lF ---d- - u F Ir t l. I ln lo t"l! L__rL l I --- .. --- J t_Tlt-lt-') | --.1It--ntf- ><x = Ic =. z. =rtl U) + ? oO E s tLnlrfl lz,t-l"?1 :>z. I -. z. =rrl E5 !!.3t|f -l o F,Fg g 3:E Eq aF'#5 S EtitEl F'lllElz tt! oo t ---l t-lt- l=l z, I cz. =. = -an 5g e.ilof -3 o $Fg" s 3aE a"f, i#s -(! .? xlrl Fl -l I I + I :lFts Fll tlEzl + + + c -'uols 0N cNnvm lsglg op?roloJ .ll?A J tulp[ng lso/tr p?ou ot4uord guoN stl OlqsproJJv I00rJ slppln[ ,gta1lglfi rFFoJ 0A!19T0f rtqptl mrm 0oylfDc [aEEr] 0{t In ,lm Jusl, lwf 880rrr&tJ ox$t,|vld ttntrrtrrcrv'c'd 'SIcEItHCUY 11tqO '00d '62 aunf ilvo 0lz0 '01,t lcroud : I + + ,0-,1=.91/l :l]vcs SU]BI,INN ]INfl _ NVId ]3VUOlS H l NV H il/c 90t8 d0tc corJ | ouc ro Irou ] 60tc I lll}0ttc 0tec 0lec t0zJ ry/ stn /r ,* 90zc 80tB 207,8 t0t8 t0z8 'l zrqJ +;,rc\ EI ersc \4r / s,sr 1 Ft0'i/ srsc'l T;,-'l z0'c t0z8 t0zB/ ttgc-l tt*-'l_ ,,or\r.lM {gl'tl 16qc / ,0,-'lry fotc 9028 9028L'-J I ,'*J *l / tzgt "l n-l 90tc iD 80zB zoc8 LOZB l0[8 / ugt -t n-l ffi lzw "l I*t_z09c \Lj',,try I l sec /0tc / ,znt'l {,J 80m / srec 1.--.,lI mlc tzsc 0zqc fl9C [9t I,;, 1_,_ L_ ( tztJ 90sc /0t3 80zc /0zc 90zc mn t0tJ 30n le0f8 90f8 | r0f8 tof8 t-t/y f g5l24l2ag4 1g:51 Da 3a367a715h ODELL ARCHITECT PAGE AL ODELL ARCHITECTS, P C te: To: MayA,2Il04 Total # of pages:2 cc: Re: Fromi Remnrks: Errc ; ones P:\1-02- I 0\:'*-mor\far-banr\02 | o-fsa-Ch |di6D.,vi$.doc Dopartmsnt of Community Development ?5 Fronqep Road vail, CO E1657 i Phonc:970.479.2142 F a* P h o na : 970.479.2452 Middle Greek Erlc Jones Odell Architects, P,C. 32065 Castte Court, Suite 150 Bvcrgreen, Colorado 8(X39 i.,.,..,....,..,..,.,....,.,,.,. Phonc:303.6?0.59E0 Fax P h o n e:303.6'10.7162 For'four Use I For Your Review I Please Comment n Urgent ! Charlic. Amc hcd ir; tho assembly thst we ar€ proposing for the Floor/Ceilings at the Middle Ctcel: Housing projec, I wanrcd to verify that you will eccept tlrls toeted assenrbly. I will call if ou tomorrow to discuss. Than < you, g5l24l2aa4 18:51 ! StC.nd IIC v||lu.r c.limrr.d by I,|v4 L. A&mr A {ooi.t t, Ilr Fire Tert conducted u Gold Bond E rildir\g Product$ Rqcqrh Ccntor Third Prrty Wihess: Wordook Henry Int{rmotiooEl, Ino. oDELL ARCHrTr.t o Corrytj.dtrO?XN, /TMEN,ICAN FOREST ' P PER ASSOCIAT|ON, INC 3836787L62 a PAGE 62 WIJ-1.2 One -Hour tr'ire-Resistive Ceiling Assembly f,'loot'/Ceiling - 1000/" Derign Load - I Hour Retlng - ASTM E 119 / NFPA 251 2. Floor Sherttlng: Minimum 23132 in:h thiot tonguaan&groovc wood ehoatring (Erpoeurc l). Inctalled pu code -rcquirernnts with nriuinrm Ed corunorr nriftr, md glued to joist top fllagpc rrith APC-01 ooustruation Edhesive. 3. lnrulation: Minimun I -12 inoh thic < minoral wool inruletion bata - 2.5 pof (nominal), srypoded by rerilient obannolr, 4. Structurrl Menberr: Wood l.joieb ryaceril a marirmrm of 24 inphos oo center. Minimum l-joiet flange d€pth l-lfi.inalrrn Minimum t-joirt flange area: 5.25 inphecl Minirnm l.joist rveb thickness: Z16 itrFh Minimum l-joirt dqdr: 9-l/4 irches 5. Rccillmt Chrnnelr: Minimum 0.0 I 9 inoh drick galvanizcd rtccl $eili.ot chan4els, *teched perpcndioular to l-joistv using 1-5/8 inch lrmg drywdl sorcws. Restliert chunals spaced 16 inchps m cqrla rnd doubled at each wallboard ard joint exteoding ur the rextjoisl 6. Gyprum Wdlboard: Minimum 5/8 inoh ttrick $rye C gtrrysuru waltboard iffitalled with loog dineasion papendiculu to resilienr clutnncla and fastened to each c rannal with minimum I inch looe Type S drpvall scrcws. Paetcners spaced t2 inchee on oeoEr in. the field oftho wrllboar4 I incheo on carEr at wallboard endjoints, and 3/4 inches fiom panel edges and ads. Bnd joine rrf wallboasd staggered, 7. Finirh Slltem (oot rhown): Face lry er joirtts oovered with tape and coatcd with joint corpound. Sc,rsw hlads covored with joint oompc,und. rure 19, I9E4 Repon Noi wHI-6944159 8t*lt {qj :-,..,..^.,K_ {ful. Floor Trrpplng (optional, [ot rhown )! Gyprum concrotc, lightwoight or norrnal confuelq At GRICAN WOOD COrrNclL Mq ZO0Z Frcm: To: Date: SubJect: "Barry Monroe" <BanyM@Shau€onstruction.net> "Bill Gibson" <BGibson@vailgov.com> fnU2@410:57:14AM RE: Middle Creek - TCO Gentlemen: So as not to waste your time, we won't be requesting your pres€nce today for TCO inspection at Middle Creek. The fire alarm system piece is still needing some help - there is a meeting at 11:30 am today lhat will hopefully resolve this piece. lf you can hold onto the TCO inspeciion cards like you mentioned on Friday for another day or so, I will keep lpu informed on hov the fire alarm piece is getting resolved. Any other unit inspections, etc that were on the books for today we still want lo have happen. thanks Barry Monroe CG: "Charlie Davis" <GDavis@vailgov.com>, "Greg Denckla" <GDenckla@vailgov.com>, "Maft Gennett" <MGennett@vailgov.com>, <RForrest@vailgov.com>, <LSandwal@vailgov.com> LAl26/2aa4 LL:.24 3A36747L ODELL ARCHITECT OYPSUT' WALLBOAIO, STEEL CT STUDS One laysr 1" r 24' proprielary \rp€ X gyrsum plnets insort d b€twoen 2rl2r floor and oelllng J runnars with T sec{on ol 2ll2" I ecl C-T strds between pan6ls. OPPOSITE $lDE: Baso laye/ tA" praprletl ry typ" X gypsum wallboard applled at righl angle3 to $ludB wilh 1" Type S drywall sc €ws 2# o.c. Face lryar t/2' propdetary type X gypaurn w{ lboad applled parallel lo sfur lo with 1s/r' Typ6 g drywsll scnwg 1?. o.c, Sound looted ffth 17e'glass flber Insularlo' In shd space. (NLB) PROPHIETARY GYPSUilI BOARD Amsdcsn Gytr,sum Company - rA' FIREBLO0 WPE C- .I. FIREBLOC SHAFT LINER PABCO Gyps m - 1lz' FLAME CUBB. auper'C'- 1'PABGOnE Gypsum Llnef goad Temple-lnland FotBsr Product! Colporation 1/2r TG.c 1" Silenl Guardfl Gypsum Lln€r Boqrd GYPSUU WALLBOAIID, STEEL CT STUDS Ona lay6r 1" r 24t proprielary ty?e X gyp ium ptnels Insened batu,€en 2rlz'noor {d cEiling J ru lnels wllh T sociion of ?/2' s1 eel C-T str.rds betw€en penol6. Frce ldycr rrt' proprietary Vps X gypsum wqllboard app led parallol to sujds wfih verrhs,jotnb midliray belween stids and lalnlnar.d tr propriefr ry gyFum panols urllh 4'urlde slrlpo 0f teping compound at wallboad rhe pedmeEr tmd vsrtical c$brllne. I l/r' Typ€ G dryflall scrows 24" o.c. located ll/r' bgck {rom ti allboard odges and al v€||lcal Gntodlne. OPPOSITE SIDE: Bars lsyet r/zr pmpdet! Iy type X gypsum walbo{d appll€d at dght anglas to s:uds wlth 1' Type S drywall screws 24' o.c. Face layer 1/i' pfoprletary typo X g1Dsum w;llboard apdied patallel lo stu(b with l5A'Ttpe S drywal 6cr6do 1?" o.c. Sound tesled llh ltl.' glar$ flbar Ingulalion in 3tud Epare. (NLB) 62o Thickness: Limlung Helght: Approx. Wolght Fire T€st Sound Tcol: PAGE A7 gllt R€f€r to manufaoluret I psf uL HZt94, *3NK8151, 9-14"S3, UL Deslgn U428 RAL Tt33-181. 7-1-S3 ''',,1..:.' * tta i+ r-l^*j l,-*- ll +-.a+"r.r, --lI ,*,orl. PROPRIETAFY Amsrican Gypsum company , PABGO Gypsrm Templs{dan0 Forcsl Prcducb corporatlon !YP51'[I BOARD tr' FIHEBLOC WPE C- 1" FIBEBLOC SMFT LINEF- tht FLAME CURB. Sup€r'c'_ t, pAEcoREooypsum ",Ui?#s- 1' Siled euardrM Gypsum lJner Board '.'..t..: Thickneso: Uniling Height: Apprfi. Welght Fir€ Tesl: Sound Tesl: a Retor b manufiadt t€r 11 psf See WP 7051 (uL R7004, SiNKS151, +l+09. UL Deslgn U428) 56€ WP TGtl (RAL T$0-181.7.1.S3) GVPSUM WALLBOAF D, STEEL (ifl SruDS, MI}IERAL FIEI :8 INSULANON One layer 1" l 24" propdotary lype X gTpsulr panels imsrled between 4' floor end ceiling J runnsrs u,tth H soclion ot 4" proprietar/ wnled C.H 9@l suJds bet ccn panels, 3' pEpdetary nlrrral fib6r insulatlon, 2.0 p( I, h 6tud spa6e, OPFOSITE SIDE: Ons ley€r ./." ptopfielar) type X rypsum wallboard +pllsd parsll€l lo etuds with 1tl.'Type S drywEll screwg g' o,c, al edg6s and ends and 12" o.c. at intErm8dlallr sluds. (NLB) PROPRIETAFTY I :VPSU[' BOAND Unlted Stat€ ,Sypsum Company - o/r" SHEETFOCKo Brand Gypsum Paneb, ULTHACODE co|€ 1" SHEETROCK6 Brand Oypsum uner penelg ' .'..f. , '\A/lyfu\ 1 ThicJooss: 481.' Limiling Hoight; Refcr lo manufacrurer Approx. Welght I psl Firc Test uL 81319, glNKtals2, 11-18€1. UL Deslgn u4a2 Fiold Sound too[S^-010!r13, 0..12-01 .: "'...1 ..: MAISAA( f: A..enn enna I |l^hla^ lha B.nlf!.nr'g a^t tu'-.l.rollarl l.t^d.ri^. ^^ --^;^,--, ^F..,t-.- LAlz6l2gO4 LL.24 3S367a7LEL' lvlL v Liulo).ng Dearns - Kev$eucomnrenoauons ODELL ARCHITECT Eric Jonrrs From: Clregory P. Luth [greg@gpleinc.com] Sent: Friday, Oclober22,2OO4 3:26 PM To: H,ric Jones Cc: pauls@shawconsl.com;lluEsMartino Subiect; illCV Landing Beame - R3vbed Becommendations G€nll6men Please disrel;ard my last e"mail on tf is subject. Paul informed me lhat the stair header is a W10x17 as shown on the structural drawings. That beam lrorks fine. The reinforcilrg thal I suggested for the other beam do€sn't 6atl6fy the fire requirements unless the 2x members are f ire treat(ld. Paul said under the r)lrcumstancos, il would be easler to install another 6x10. The new 6x1 0 can go side by sirle with the one that curr)ntly tram€e into the header beam about 6 ft. from lhe north wall or half way between the north wall and the existittg 0x10, Have a good weekend. (ijirer:rrr'l P. Llrih. S,t:,, Fh.D. President ar.d Chief Engineer (lregtrrv F. Luth & Asnociotes, Irw 3350 Scott BI'rd., Bldg 21 Santa Clara, t3alifomia, 95054 PH: 408 6540475 FAX: dO86540475 CELL 415 310 5955 E-mail_grsg!! lgplatns"qem-srat[9i& ps@SpJaincccna_ Web: -ry.y;li.gplainc.com <http://v.fry-,gplainp$Am;'- PAGE A6rage I oT I t0n2n004 PAGE 85LAl26/2404 LLi24 ODELL ARCHITECT o 'llril ,r.t iii D --1(t o E $ J,f Jt .- $-I iil lt $ t++ I t€$ 4gJ-l.4 \d rl lrt,.t I, trl ttl (rl llr . <r.e.D tO/26/2A94 lL:24 3936747L62-o I\n{. ODELL ARCHITECT PAGE A3o Lvt. l'al*| -- €ir'lcuc', f'J{' G) 3* *{. }\*Ai-q.J wtry,6'{tos 6 vlo l"l.ou tt["r - L"\+aon-\., "c.fior, 1b (e) bxto. .\6v-s-z )-/i -z : ::. : - :.:,:......=-.:y - *' - PAGE A4ODELL ARC1IITECTL6/26/2AA4 tt:24 3A367A?t62-o W o D 4 3F,tJ ctI$+ Is3tty fp r-5' C-, N ,{tH g-$rx -r ,/a\9ds-i-i t o;,s--ZF Fq$5 tq \---J (.-t r -0td .1t$f-z o lrTrlxl+ ,.9 Ulf zt 0,b 9-L J T / L F vJ $\T/ 0DELL ARCHrT."to ODBL L ARCHITBCTS, P.C 07l2al2qq4 14:55 3A367A7L62o PAGE AL Date: To; Re! lromr R,erna,rkrl July 2t,2004 I Gree Denckla l f Town of Vail Dept Euilding Department ?5 Frontage Road vail, colqra.do 61657 i Phone;97O.479.2369 F a x P h o ne : 970.419,2452 ffi Clnorlr, .,, Pleqsn,Rpvt"u-r Eric trones Odoll ArchiFdts, P.c, 32065 Cartle Court, Suite 150 Evcrgrecn, Colorado For l'our Use !ForYour Review I Ploaso Comment I Urgont ! Gtel:, Hen are hc wall and floor/ceillng asscmblios por our discussion tho other day. Pleare reriew,and let us know if there appear to be any more issrcs. Also attached is $,1 roof/cciling asscnbly. Pleere pass rhis along to on hio return. Thatrk 44 Edc tone6 g7/28/2aa4 14:55 3A367O7L62- I-_ioist 2Jayrrs with RCs O oDELL ARcHIrt.to lMJ-1.6 One-llour Fire-Resistive Ceiling Assembly Flloof/Ceiling- t00o/o Decign Lord - I Hour Reting - ASTM E tl9 I NFPA 251 l. Floor TopF:ing (opdourl, not rhown): Oyparm concrtrte, lightweight or normal concrte topping. 2. Floor sherrlhing: Minimurn 2342 inoJr thick tougue-asd-growe wood sheathing (Exposure 1). tnstalled per cod€ requirenranb u'ith minimum Ed cornmm nails. 3. Inrulation (optionelo not fhowu): Insr ilatim fittei botrroen l.joisc $ppofted by the resilient channcls. 4, Structunl -'ylembergl Vr'ood I'joists qrared a maxlouro of 24 inchos oD oentlr. PAGE A2 Page I of2 Miaimum t-joiet flange depth: l-s/lf ioohos Minimum l-joist web thickneso;3/8 irch Mlnirntrm l-joist flalgo atta: 1.95 inchef Minimurn I-Joi$ d€,ptb: 9-ll2 incbec 5. Rcdtleut Clrennclcb: Mirimum 0.019 inob tbick galvadzcd sccl rcsilicot ohrnnel attached pc,rpcndicular to thc botmrn flange of the l.lioisb with one l-l/4 inch r trf,well eorcw' Chaancls speced e maxirnum of 16 iochee m ccnter [24 iochee on center when l.jorsb are spaced a malrimu n of 16 inches on ce,tmrJ. 6. Glprum lYdlborrd: Two layers of minimum 1/2 lnch Tlpe X gpnunwullboardafteched urith the long dimencion perpendicular 1o the reeilient channcls as :bllows: 6a TVdlboard Bare Layer: Basc layr of vallboard attached to resili€ot chmncls uing l-l/4 inch llpe S dryrvall sorews at 12 inches oo cqlter, 6b. Wallbo,erd Face Lrycr; Faoo ley r of wallboard attached io resilient chaolcls through base layer usiog 1.5/E inch'type S drfiwall ecr€ws opared 12 iaches on c€iligr. Edge joitrb of wallboed face layer olfser 24 inchee froffr ftoE€ of baro laycr. Additlonally, wallboard faco laycr atmohod to base laytr with l-l/2 itroh Tlpe G d4 wall rorcwe epaced I laclu 'g on c.ntsr, plaod 6 inphes from faco layer ond join6. 7. l'idoh Syct'im (not rhown): Face laye I joint covared with tape and coated with joint compound, Screril heads covct€d with joint corqrcund. Firc Tesr c(n&rctod at Natioqal Resei roh Council of Canada ReportNo: A-'1440.1 lwe24,1997 I Thir i|rcmbly ma! d5 bo utcd la r (lG-rrrst roof/q iliu rypliertirn, brl erft wtrctr c<a*nrctccl qr:ly 5 <lcrribql, b Dirccr unchmcor of gyprut| wdlboqd in liar of |ltl tnstr ro I! lliam cheonsto ir Dpioe[y it€rn€d rcc.0(.bk. fual Swsum wlIM is dirtatly rl4ch€d to thp IioJ3b, $c wallbord strould bc imhllcd riih long dir cruion pcpcodiculu b Oc l-Jotrb rrd inarlrtion rhould not be upportsd by tho wdlbotd. o STC rDd llc vdxr .'ti"nFd tv Drvid t- Ad|rn AsFal$lr, ft|o 07/2e/2494 3936787L62o oDELL ARcHrr."to PAGE A3 00tr0-cYP. 80.; 5/b' TIPE )( flNM-RESUENT ftINNEL ffiM -tlOOD SIUO FRA}IING; 216, Rs Structurol for goc.ing O72O(, - RBIXO.ASS SqJND ATIENUANON BATTSI I l/2' UA)(, lllltrN$S 09200-GYP.8D.; s/8 TIPE X utE O UII T fi2, RI AIIAGIB) SNWruR{- $IEIS FOR AOJIJSIID IIAIUIIO PATIER}I. NIW )EMISING I/|/AIL IYPT lllll1 & vll12 GA Flo llo trP JzJ0 ($) + + t oDELL AICf,ITECTt, I C. Itrntrl6firr hrrrrro lnrucra !fi6 cnEdm. ulto anmc[!N 3r1lfdflr Wl ru td* Sf,tr lO Middle Creck Affordablc 129 North Frontagc Road Vait, Colorrdo tl55? PR0ECT ilo. 0210 DAIE Jrlr 26, 2l[1 DRAnlG [O sK-02-01 + 67 2A/2644 14:55 oDELL ARcHrrt.to PA@ g4 09250-GYP. BD.; 5/8'I]FE )( flfi[-RtsuEl{I slNiln {F260-0YP. BD.; 5/8' TYPE t (lfiM. tl()t}O SIU[) FRAIIING: 216. Rs: Structurul for gochg " - ['lf ft?'1TrPilhlilt'#f,S- 0s2[0-cn, BD,; 5/8' IIPE X NOIE SATIE NAIUIIG PAIITRI'I AS BS0nE U/ R.C, Al'rD Gn ot'tn lm. + + :t Middle Creek Affordable 129 North Frontrgo Road Vdl" Colorado 81657 PR0,rcI ilo. 0210 DAIE trly 20, 2004 DRATII{G ilO: I }I.I IoDBtL AlCf,tTtCTr. P c.l Arcrtrlcrorr Ptulrre lrurros Iue cllllrurl, ur ro 8m alm !{r IH'..-. 5t*Y:_l + sK-02-02 A7/28126a4 14:55 0DELL ARCHrr."to PAGE 65 09260-cn. BD; 5/8' IIPE x 000m-Rsrutt{T U1NNEL mrm-ruwom, t/z' 06100 - IIOOD SIUO FRAIIING: lx6, Re SUucturol for poo'ng '* - fllfftllTdnlP/ffi1f,H' $260 - 0YP. BD,; 5/8' TIPE X torE 0 ilJ & ur+ RE AnAOm $RUCruRAT $EIS FON ADilSIE0 ilA[StG P,\Tnil, NElll ]EMISING IIIIALL TYPE IilI1J & |'ll14 SCAIE J'=1'-0' 1 -tf f IIttt}r.l IDBLL AlCf,tTBCTt, I C. IArcrtntcrlr Purru. Ittlllo|! |ffiqi com,tm|! 8Elqtlnfitaffr ITd-rr IUnru r* Irmry_-| Middlc Crcck Affordable 129 North Frontagc Road Vail, Colorado 81657 PR0tcT !10 0210 OrtIE ,l{t 26, 200+ DRAIIG tIO o + sK-02.03 PAGE A6oDELL ARCHrr..to to $ Is 5o E c,{ IJ A bRon fl --1 5 E, |ll EoZU, .tt * =t6i e= a !I t tt :il cIII eg'e? !D d. d.ae tttt 9' B!t EF E a5 E .E Eg Bi e E l{ E T g Ea E P 8oIuroz IJJ UJGo .E o2 =$ d (9-6J a E z t Effi$ i gggg o t To 55i# gggg o .t !d issH gggg @ Ez E - r - rld 'EEEHsgggt F a.|z 6 ,"8' tlgsg (o sz I E8555 gggsr a =to E5F55 $gslg ! .El o EE55E gggs9 E go EEEIg gggSs ez 6 $ $tF;$ E r*:gE t 9E5EE B}gH3 '13431 A7l2el2gg4 14:55 3s367s7LT ol-l EI It ls i=ffi 9gs 't:r l1 oz E a A7128/2944 14:55 3a367a7LT oDELL ARCHrTr.to FF -* ItE,I I .sl* Lr= PAGE A7 g s F 6o Eo { E o-a F(, .ExJ 5e fi E(,zcn6P =F6:o= Fg aa, ? It EI E 3 uJq 6ulEo f 'EIo t I!l tg IEI s B a I !2 I * I E @ -BI .to z =f cl .J # g 9o FEES' ggggE 3 z !o s ig#ffi g3g3s 't3/\3'l [Ui* il{-l'= T(, t.|zoJ =el oz JJt Yoo =q 5 tO .o Iz G6 ;EH sls t4 5z Io ;;fi ggt =z !6 FEH ggg ., ;z go 55# glg 5z t E5H ggt at i 5,ffi tgg !,(\| 13/\31 ill€tcHU EEaadddb hBEI E8!gluoo 33gE DOs.sFF i.r h 8E,e ,! u,t uIzzoo E'Sgg g7/2U2AO4 L4:55 3a36707161 oDELL ARCHTTE.tO tlregory P. Luth €s Associates,,lnc, SitructUral Engineers A BuilderE 3150 Scott Blvd., Bldg. 2t tlenta Clarr, CA 95054 Ph: 408.654.0475 Fax; 408.654.0476 Phone Conversation Log # 5 F@t-ilt"-l-itibr----l- Comments: Ileference S2,5 (C ), 52.6 (C ), and S2.7 ( C) :The sheaf, walls / dimieing wall schedule issued 7/13/Ot whioh updat€d many of the walls to one sided drywall did not address tt e buildings located around the Main (C ) building. Thcse are located South of grid D and East of grid 8. The party walls on buildings can be une sided drywall walls, tlpe Wl I from the schcdule. PAGE O8 GPLA Participents:Distribqtion: GPLA Rrusel Martino l9VEndy Taniwangsa Shaw PauI Shultz Paul Shultz Odell Eric Jones Ownef Other Action Reo'd rhin 7 days o, uith the conh y altrchmen butclafifies zrtiee that nt t(t Information only: Ltnless notltied in writing w' r'zcipients are in agreeflent I fitllowlng lnfornatlon and at 'lhLc record is not wrbatim be used to inform iwolved 7 ' document and any attrchme t f the "date of menw" it shall be asstmed that the m* of this memo, Any disuepancies wtth the ts chould be brought to the attctttion of the sendzr. architecutal, sttuctural, and other comments and wtll t*d decisions will proceed as indicated by this Phone Log.xls PL#s 04-07'14 g7tzu2EA4 14:55 3435767161 ODELL ARCHITECT ^ PAGE 69 07m - AIiTHALT $ilNCLI$ --.{ lerturcd 00000 _ sF:fl ilEI|tsRA||lE __\ 06100 - R(IJF S||EAIIIINC; 5/8' ---" 06100 -PR|:-EN0NEER[D I/000 -rTRIISS; Rer Shuclurol \ 07200 - BA tT lNSULATt0r{; 09200 - 5/j' CYP. B0; I lslirs -.--.--If e 'C' on resilient' cn(finel 1H0 R RO'OF + oDBtt ArcErttclt, I lBclr'|totrrr Furrrto llltrrdl l6qFlrcnilE|! E&CumndI{|rt: !r!t0 fHr lit ltlo Middlc Crmk Affordablr lE North Fmntege Rdd Vril Colorado t1657 l _l PR0,,tCI t{0. 0fl0 DAIE lodr li,200+ oRAS!N0 rio sK.l0.0l ,,-t) Design Review Board ACTION FORM Department of Community Development 75 South Frontage Road, Vail, colorado 81657 tel: 970.479.2L39 fa* 97 0.479.2452 web: www.ci.vail.co.us Project Name: MIDDLECREEK SnE SIGN DRB Number: DR8040228 Project Description: MIDDLE CREEK AFFORDABLE HOUSING SITE SIGN Participants: OWNER VAIL COLOMDO MUNICIPAL BLDG06/04/2004 Phone: 75 S FRONTAGE RD VAIL co 81657 License: APPLICANTOdellArchitects 0610412004Phone:303-670-5980 32055 Castle Court, Ste. 150 Evergreen, CO License: C000001534 Project Addrcss: 75 S FRONTAGE RD WEST VAIL Location: 129 N. FRONTAGE ROAD Legal Description! Lot: Block: Subdivision: Parcel Number: 210106400003 Comments: drb directed administrator to staff AP BOARD/STAFF ACTION Motion By: Action: STAFFAPR Second By:Vote: Date of Approvalt 0710912004 Conditions: Cond: 8 (PLAN): No changes to these plans may be made without the written consent of Town of Vail staff and/or the appropriate review committee(s). Cond: 201 DRB approval shall not become valid for 20 days following the date of approval. Cond: 202 Approval of this project shall lapse and become void one (1) year following the date of final approval, unless a building permit is issued and construction is commenced and is diligently pursued toward completion. Planner: Matt Gennett DRB Fee Paid: $60.00 07/06/04 TIJE 1L:57 FAX 9702451015 Comerclal Deslgn @ 001 d..,Commercial Deslgn Engineering, Ltd TO: ATTENTION: CHARLIE DAVIS AT: TO\AN OF VAIL FAX NUMBER: 970-479-2452 DATE & TIME: 0710610412:03 PM # PAGES: 6 FROM: SENDER: MARIA PRINCE AT: COMMERCIAL DESIGN ENGINEERING ADDRESS: 1OO3 WINTERS AVE, GRAND JUNCTION, COLORADO 81501 FAX PHONE: (970) 245-1015 VOICE PHONE: (e70) 245-0595 MESSAGE: HERE IS AN UP DATE ON FIRE STOPPING FOR THE SHOWER DMINS. IF YOU HAVE ANY QUESTIONS PLEASE LET ME KNOW. BEST REGARDS, DON CREATED Wltl WI{COVER 3.1e 07 /06/04 TrJE 11:57 FAX 9702451015 Memo Tor Flor GICI D.til Rc Nlels Jepsen and Richard Cordora DmaldSdranalan Jlm Hyde, Paul, and Charlle Danis July 6, 2004 Fire stoping d shouer dnlm. Connerclal Deslgn q oo2 This mqno is in regalds b tre Hilti enginsring judgment for he show€r drein fire sbpping. I have talk€d to Chaiie Davb at the Torar of Vdl and he was onoemed wih the size of sare of the openings br the slrorrver drains. In or&r to sohre tho issu€ with he shorer drains op€nings laEer lhan 3' ute agr€ed to install ar addtirnd shed of plyrflood as shown in ho frI€ stopfing dsfrNlfor 0r€ tub In*dldlm FG.AIM. Phese refer to the atadr€d delets rega;ding shov,€r drah and fub fire dopping. lf you hav€ any questona or concema plese le{ me knoiv. Beot regErds, Donald schanemrn 07/06/04 TUE 11:57 FAX 9702451015 Connerclal Deslgn !h oo3 o o System No. F-C-2204 FRotrrg-ltk T Rotiq - ll2 Hr l. Floc -- Ceiling AEEEnbly The t hr fire-luted solid or trussd lumber lfst floor-ceiling osscmbly slnll be constructd of the motsiols ond in lhe monncr speciflred in the indilduol 1500 Seri€s Floor-Ceilhg Desiglts in theUL Firc Resistonce Okectory. The gnerol construction feotures ol tlrc floor-ceifng ossemb! ore summodzed bclou: A floodng Sptem Lumber or plyrood subfloor rih finish floor of lumbu, plyuood or Floc lopping llixfurel os specified in the indiriduol Floor-Ceiling Design. Rec{ongulor cutout in flooriq to occommodote th bo0rtub druin plping (ltem 2) to be mox I in. by 12 in. Cutoui to h potched on undenide of subfloor using one loyer of mln 5/4 in. thick flpood 0r min 5/8 in. thick gypsum boord (ttem tC) shd to hp min 2 in beyond eoch edge of reclongulor cutout. Pstch split into tro piects of opening ond hole-somd for Mhtub droin pi$ng. Diom of opening hole sored thmr4h pot$ to occommodote druin pipiq (ltem 2) b be I in. lorger thon ouhlde d'rom ol droin piping ond positioned ruch thot the onnulor spocc bctreen droin piflng ond pdphcy of opening is min 0 in. (point contoct) to mox I in. Tto pieces pdt'nned oround droin pipir4, rith cut cdges tighily butted. ottd scnr-ottoched to undenide of srbfloor rlth 1-1l in. long eteel scnrs spoced mx 6 in. 0C. B. lhod Jobtsf ibn l0 in. dccp (or dcpr) lumbcr, steel or combinotbn lumber ond steel joirb, truscs or Structurol lhod Mcmbasr dth bridging os rcquircd ond rith ends fkestopped. C. clpsum Bocdf Norn 5/E in. thic( 4 ft r'rjc os spccified h the indlviduol Floor-Ceil'rng DesQn. A-l Rrprodwcd by HlLIl, Inc. Cottcct ol Undrrrrtss l-obcsbrils, Inc. thcrmbcr 7, 2001 07 /06/04 I'IJE 11:5E FAI' 9?02451015 Connerclal Deslen B oo4 System No. F-C-2204 FRoUlg-ltf T nofirg - l/2 Hr 2 lhoh Pfing Non 1-112 in. (or smoller) dion Sdrcdule {} ocn/onlkile butod'rene styrcnc (ABS) or polpinyl chkride (Pt/C) pipe ond droin fittings cemcnted togethr md proridcd rilh ABS or F[ hthtub rosle/outrflor fitlings. Arnuhr spoce *0il be min 0 h. (po'nnt contoc{) to mor I in. J. lll Void or Cority MotsiolS llin 5/8 in. depth or fill rmhriol cpplied r'rt'hin the onnulue, f,ush rih both surfoces of plpood ot gypum bood potch, HLn CoilStRuclloti ffiElilcAl-s, uv tr tilLll NC -- t5-0m Seolctt rBeodng the UL Clossificstion tlork Rc9roducd ry HLfl, hc. Cdl'tcly of Undcrrrltcrs l-cbomtodrs, Inc. thambcr 7, 2001 07/06/04 TUE 11:5E FAX. Jul-06-2004 08:tOstn Fron- 9702451015 CoDnerclal Deslgn To: Gompany: Phone: Fax: Date: Gomments: 43721a Don Schanaman s70-245-1015 7l2to4 tI I hr From: Company: Phone; Fax: Pages Includlng Jonathan W Mafthews Hllti, Inc 918-252-6181 918-254-1679 fr.bltfia*.cra Jonathan W Matthews, CFPS Fire Protcction DePartment Hllti, Inc Gover Page: 2 Because of the numemus flcld conditions Gncountered, lt ls not allvays posslbb t9 ldentify a firostop "V"tgm thet has bcen tarteClasssn* fy. natlonally re-coOnized naeneL!9$ testlng laboratory (cuch a's Unairwrfters Laboratori6;-il4;t Uutual, Omega point, etc.).. ln euch ' c€6€r an Engineering Jrag.unt (;'Et") may be approprlate. in EJ t"presenfu ! tirestop system that would be expccted io Pass the sbted ratlngs and requlrements if tEstsd. All Hilu EJ's afe deelgned in accordancc with thc Intemqtional Firestop Counsel.(lFC') guldelines' These EJ,s are designed uv oui'experreneeo degreed fire probctlon enlineers using, ae the basis for our opinion: . rel€vanl S'n.p"rty olqsslfled sys,tdfls testcd ln accordance with ASTM EE4, ASTM E-119' ASTM E-138,'nSffirf e.Sf+, Asrr,lt e-tsee, ULo.S11$95M. UL 293, UL 723, UL 1479' or uL 2079,. wide-ranglng rolated internal testing of our firestoP produeb, and . e'1.nsive knorvlctlge and algerlenca of tha performance characlprlstlcs of Hilti flrestop produds, and fireetopping t€chnology generally' pursuant to IFC gulrtellnes, each El ls intended Jor one specific jobsite, slnce evEn sliEht variances from one applicatlon to the neK cqn affect systgn peformanc€' Best regards, @ oos T-0f5 ?.801/ooz t-ts1 07 /06/o4 Jq l-05-?001 TIJE 11:59 FAX 9702451015 06r60an Fron- Counerclal DeslSn @ 006 T-018 P.002/002 t-ts| EnstnrEntnc JUDqIENT FIRESToP ur?u ENgfCN RTDNE CREEK $flHNBLE IflUStNG Cg11g6gf[[r C0E F-RATIT{6 = I.HR. cRINs-sEcTIIltlAL VliY 1, v00xl FL00R/CEILII6 ASSEISLY-ISISI CLASSIFIEID (l-HR' FIRE-RATI]'IO', z. nAxlt{ul,t e, N116NAiriiitriE[ fil-E n14lfii stlgvEn DRAIN AllD PIPE' i. iiifriitili gj +;-DLTf fr nii.f i'r1-qltr- rritnEscenr ruF-sI-nP-!EALANT' 4. Hrr{n{uu ye' BEAIT hiiTiii-StEldiw-riatfi FIRESTIIP SEALANT APPLIED AT POINT IIF CONTACT. THF oomffi rm$r Elnso[s Afn[$r s.srEr nr!_ryJ E ffisru m pAs nr sTArrJ RArr]Gs F rEsTEr -(ffiEi[iif;ut lfiiEtt m,r+-mso t F{-? HILTI, Inc. Tqtsc, Ekhhono USA (918)!/+' = l' Irpmtfui and €dnw, 07/06/04 TUE 08:16 FAX 9702451015 Co[nerclel Desl8n B oor d'., CHARLIE DAVIS TOWN OF VAIL DATE &TlMEr 07106104 8:4E AM COMMERCIAL DESIGN ENGINEERING coLoMDo 81501 VOICE PHONE: (970) 245-05es FAX NUMBER: s70479-2452 FROM: MESSAGE: I HAVE RECEIVED THE ENGINEERS JUDGEMENT FOR THE FIRE STOPING FOR THE SHOVER DRAINS FOR MIDDLE CREEK. PLEASE REFER TO THE ATTACHED SHEETS FOR DETAIL. IFYOU YOU HAVEANY QUESTIONS OR CONCERNS PLEASE LET ME KNOW. BEST REGAROS, DON CREATED WTH IMNCOVER 3.1! Commercial Design Engineering, Ltd 07 /09/04 Jl l-06-ZUqa TtiE 08:48 FAX0E:50ail Fron- 9702411015 Connerclel DeElgn @ ooe I I Er From: T-018 P.riltolz F-ts. Jonathan W Matthews Hlltl, Inc To: Gompany: Phone: Far: Date: Gsmments: 43721a Don Schanaman 970-245-1015 7l2lo4 Company: Phone: 918€524181 Far: 918-254'1679 ft.ft-ll('a*.cm Jonathan w Matthews, GFPS Fire Protection DePartment Hilti, Inc Pages Including Gover Page: 2 Becausc of the numeous field conditions encountcrect, it is not .always possible to ldantify a firestop ;tG;6;i tr"" uren tu"t.l lcrassririi ti i nlttonatty rellgnized independelt testing labomtory (such as underwritem u.uor*oiJt,-F-.tt"t tll'uruul, omega Point' etc'1' In.such a crlse' an Engineerlng Juagrint (;el,) -uy U" apiriprfac. in EJ represenls a firestop systsm lhat would bc expccted to Pass the slated ratings and rcqulrcmants if tested. All Hilti EJ's are deslgned in accordance with the Intematlonal Firestop counsel.('lFG") guidelines' -These EJ,s are designed UV oui'Jlp-.-iiiii"o iier".a fire Protection enllneers uslng, as the basis br our opinion: . relcvant 3'd4arty classified sys-terns_tsetrlC in accordance wlth.ASTM E-84. ASTM E 119' nSfl, E,tsa,'i!fM- e-ii+, nSfU E-1965, ULC'S11$95M, UL 263' UL7Z3, UL 147e' or uL 2079,. wide-ranging related inbmal testlng of curfirestop P-roducts, and . e$ensiye rnon,teoge and erperiencc of ure peiformance charecteristics of Hllti firestop ploducts, and firesbpphg technology generally' Pursuant to lFc Ouidelines, each EJ ls intended -br one speciflc lobs'rt'e. since even slight variances from one aPPlication to tha next can affect system performahoe' Best regards, 07 /06/04 TUE 08:46 FAL S70245L ,r r. t-u!-100+ 06:g0eE Fro!- Connerclal Desl8u 6 oose ETA T-0lE ?.itZ/002 F-131 IL 1, V0EII FL0I]R/CEILIilG ASsEl,|lLY-t9-L/sqL. c|,AssIFIEIl) (-t|R, FIRE+ATII|o. 2. r{Axrru}t 2' iEr{rNAL'uifiten qv_c-tgl5ftc $nvER ItRAtN AND PIPE 3, r{r1nttg 3/4' DEPrI Hiiiilsiq1b:rnrUrlrScenr FIRESTIIP SEALANT' 4. ltNIHul ye' EEAD hilTi ri:o[i-dnlrliiant'FlRlsT0P SEALNT APPLIEII AT PDINT IlF CIII{TACT. rHrs tmlmDs ImE{I E,HEqs-A-tESItr SYSIil llsl uqt'[ E ryEgrB ru PAS Itf, slllttr FAIIlss r TEStn*(ffiitriiiE;rt llILTL Inc. Ektohono usA (91$ 25?:6qgq .'a.tc L/1, = t bt? LuLY 03, zoo4 Lr*t*vr&r@ UL/cUL SYSTEI'I N0. FC3044 CABLE BUNDLE THRDUGH l-HR. VOOD RATING = l-HR, RATING = l-HR, TOP VIEV-_.---v- ASSEt.,|BLY Po za alc) CJ .J: = i! SECTIUN A-A tu (_) a ID ;1 (.'z = nJ I. VO[]D FLOOR/CIILING ASSEI,IBLY (UL/ULC CLASSIFIED LsOO SERIES) (l-HR. FIRE-RATIN6). E, LUI.IBER OR PLYVMD SUBFLDOR VITH FINISH FLtlOR OF LUI'IBER, PLYVOID, ER FLOIR TOPPINC I'IIXTURE. 3. IIAnfu[ 1:'2, DIAMETER CABLE BUNDLE TO CONSIST IlF ANY tlF THE FOLLOVINII A. RG 59 COAXIAL CABLE. B. }IAXI}IU}I 25 PAIR N8.24 AVG TELEPHONE CABLE. c, ilAxll'lulrl 3/c N0, l0 AvG CABLE Gol{En, D, l'{Axlltlul,l 3/C (+ 6RND) 2/0 AVG SER CABLE (ALUI'{INUI,{ 0R C0PPER), E. IIIAXII.IUI,i 3/C NO, IO AVG I.IETAL-CLAD CABLE. F, IIIAXII'IUIII 24 FIBER-OPTIC CABLE. 4. IIINITIUII 3/4' DEPTH HILTI FS-ONE INTUIIESCENT FIRESTOP SEALANT. 5, IIINII.IUIII 5/8' DEPTH HILTI FS-DNE INTUHESCENT FIRESTDP SEALANT, lnstallation Instructions for UL N0, FC3044 SIEP 1 pREpAMTION:All surfaces musl be clean, sound, dry and frost free prior to application of firestopping materials. STEP 2 FIREST0P SEALANT:Appty the required depth of Firestop Sealant in the annular space between the cables and subfloor and between the.l iii|gypiriirilfig. tS6iitie seiiant *ith i putty t<nite io push it in place and sniooth the surface. Leave both completed seals undisturoFJ 48 hours. 2, ANNULAR SPACE = 3/4', 3, CAELES Tt] FILL A IIIAXIIIIUI,I 252 OF CRESS-SECTII]NAL AREA llF OPENING. 4, CHASE VALL OOT SHOVN, BPTIONAD THE THROUGH PENETRANT IiIAY BE ROUTED THROUGH A l-HR, FIRE-RATED GYPSUII CHAST VALL. E[E[. Sryirg tiyes through innovation & education I Hilti Firestop Guide 2003-2004 I 1'800-879'8000 | www'us'hiltr'o 'een and he 1e ;,Dry. icket .,,..-.,.JN-TENETHATION FTRES'SYSTEMS (XHEZ) Fire Resistance Directory and shall include the following construction feahrres: A. Studs - Nom 2 by 6 in. or double nom 2 by 4 in. lumber studs. B. Sole Plate - Noni z Uy 6 in. or parallel 2 bi 4 in. lumber plates, tightly butted. C. Tip Plate - The double top plate shall consist o[ two nom 2 by 6 iir. or two sets of parallel 2 6y 4 in. lumber platcs, tightly -,.-, ., .p.ning is 2 in, D. Gypsum Board* - Thickneis, typc, number of layers and fasten- eriihall be as specified in individuat Wall and Paitrtion Desrgn, 3. Through Penetrating 'Prod uct" - Max 4/C No. 5 AWG (or smallei) aluminium or steel Metal-Clad Cable+ with copper conductors. Max one metal-clad cable to be installed either conc-eirtrically or eccentricity within the firestop system. Cable to be installed approximately midway between wood ioists. Diam of openinss hole-sawdd throush doorine svstem and thr6ueh sole and tob platis ol chase wall asse"mbly to b'" nbm 3/8 in. largei than the outdide diam oI cable. Through-pdnetrating p_roduct to be rigidly supportcd on both sides of a floor-ciilihg assem- ory. NORTHERN CABLES INC 3A. Cables - (Not Shown) - As an alternate to Item 3, one or more cables to be installed either concentricallv or eccentricitv within the fir- estop system. Cables to be installed appiorjmately midway between woob 16ists, Diam of openings hole-siwed through flooring system and throuch sole and toD Dlates of chase wall as.emblv to bc nom 3/8 rn. larger"than the outsidA diam of cable r,r cable bun'dlc. Cable to be rjg- idly supported on both sides of floor-ceiling asscmbly lhe following types and sizes of cables may be used:"A. Max 100 pair No.24 AWG (or smaller) copper conductor tele- phone cablcs with polyvinyl chloride (PVC) insulation and jacket materla$. B. Max 3/C (with ground) No. 5 AWC aluminum conductor service entran.e cable tith PVC insulation and iacket materials. C. Max 3/C (with ground) No. 12 AWG (or smaller) copper conduc. tor nonmetallic aheathed (Romex) cable with PVC in-sllation and iacket materials.'The number of cables allowed within thc opcning is depend€nt upon the tvpe and size of cable as tabulated in ltem 3. The numbii of through penetrants permitted within the firestop system is dependent upon the type and size of through penetrant as taoulateo Delow: lduc- and rdent n the ough n8 Tlpe of Through Penctrant Telephone Cable Service Enhance Cable Romex Cable Metal Clad Cable Max No. of Penetrants 1 1 7 1 4. Fill, Void or Cavity Material* - Sealant - Min 3/4 in. thickness of fiil material applied within the annulus, flush with top surface of floor At the bottom bf assembly. a min 5,/8 in. fill material hpplied within arurulus, flush with lowei top plate of chase wall assem6ly. On both too and bottom of assemblv fill material forced into inter6tices of cable brindle to max extent possille. Additional fill material to be installed such that a min l/4 iri. crown is formed around the cable or cable bundle on both sides of floor-ceiline assemblv SPECIFIED TECHNOLOGIEi9 INC -SOCCSCAI 1OO, 101, 102 Or' 105 Sealant*Bearing the UL Classifrcahon Mark System No. F-C-3044 FRatine-1HrTRatini-1HI gh t- L 1. Floor-Ceiling Assembly - The t hr fire-rated solid or trussed lumber ioist floor-ceiline assemblv shall be constructed of the materials and in ihe manner spdifi"d in t6e individual L500 Series Floor-Ceiline Designs in th; UL Fire Resistance Dircctory. The general constr-uction fcanies of the floor-ceiling assemblv are summarized below: A. Floorine Svstem - Lumber or plywood subfloor with finish floor of'lurirber, ply.wood or Flo6r Topping Mixture* as specified ,rrorortrrrAroN FrRESrop sYsrEMS (xHEz) 268e in the individual Floor-Ceiling Design. Max diam of oPening shall be 3 in. B. Wood Joists* - Nom 10 in. deep (or deeper) lumbet steel or combination lumber and steel ioists, trusses or Structural Wood Members* with bridging as required and with ends firestopped. C. Gypsum Board' - Nom 4 ft wide by 5/8 in. thick as specified in the individual Floor-Ceiling Design. Max diam of opening shall be 3 in. 1.1 Chase Wall - (Not Shown, Optional)-The through penetrants (ltcm 2) may be routed through a I hr fire-rated single, double or staggered wood-stud/qvpsum wa-llboard chase wall havlnq a ftre rating cbnsis- tcnt with th;i 6f the floor-ceilinq assembly. The ihase wall sh"ail be con- structed of the materials and in-the mann-er soecified in the individual U300 Series Wall and Partition Desiens in the UL Fire Resistance Direc- tory and shall include the followingfconstruction features: A. Studs - Nom 2 bv 4 in. Iumber studs. B. Sole Platc - ttloni z by 4 ir lumber plates. C. Top Plate - The double top plate stujll consist of two nom 2 by 4 in. Iumber plates. Max diim of opening shall be 3 rn. D. Gypsum noard* - Thickness, typi, nufiber of layers and fasten- erslhall be as specified in individual Watl and Pa;tition Design. 2. Cables - Aggrcgate tross-sectional area of cables in opening to be max 25 percent of the cross-sectional area of the openinq. The annular space within the firestop system shall be 3/4 in. Cables'io be rigrdly sirpported on both sidei of floor assembly. Any combination of ihe-fol- lowing t)?es and sizes of cables may be used: A. RC 59 coaxial cable with single copper conductor, cellular poly- ethylene cellular foam insulalion and polyvinyl chloride (PvC) jacket, B. Max 25 pair No. 24 AWG telephone cable wifh polywinyl chloride (PVC) iacketing. C. Max 3/C No. I0 AWG cable (Type NM). D. Max 3/C with ground No. 2/0'AWG aluminum or copper Type SER cable with polywinyl chloride (PVC) insulation. - - E. Max 24 fiber oDtic cable. F. Thrcueh Penetratins Products* - Three conductor No. 10 AWG Metal-tlad Cable. " AFC CABLE SYSTEMS INC 3. Fill, Void or Cavity Materials*-Sealant - Min 3/4 in. thickness of sealant applied within the annular space, flush with top surface of floor. Miir'5,28 in. thj.kness of sealarit applied within annular space. flush with bottom surface of the gypsum wallboard or lower tdp plate. Sealant forced into the intersticcs;f the cables on both sides of ihi: wall. HITTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -F$ONE Sealant 'Bearine the UL Classifrcation Mark +Bearing the UL Listing Mark System No. F-C-3045 F Ratings - 1 and 2 Hr (See ltem 1) T Ratings - 314, 7 and 2 Hr (See ltem 2) L Rating at Ambient-Less than 1 CF/sq ft L Rating at 400 F-Less than 1 CF/sq ft SECTION A.A L Floor-Ceilins Assemblv - The t hr Iire-rated solid or trussed Iumber joist floor-ceiling assem'bly shall be constructed of the materials and rn the mdnner speiified in the indjvrdual Lq00 Series Floor-Ceiling Designs in th-e UL Fire Resistance l)irectory. The 2 fu fire-rated wood ioist -floor-ceiling assembly shall be constrticted of the materials and in the manner speiified in Design Nos. L505, 1511 or L536 in the UL Fire Resistance Diiectory. The general construction features of the floor- ceilinq assembly arb sumriarizcd below: A. llooring -system - Lumber or plywood subfloor with finish floor of-luriber, pl\.wood or Flodr-Topping Mixture* as specified in the hdividuaf Floor{eiling Design.-Ma-x diam of flooiopen- ins is 2 in. B. Wood Joists* - For t hr fire-rated floor-ceiling assemblies nom l0 in. deep (or dccper) lumbet steel or combin"ation lumber and steel joists-, trusses br Stru(turel Wood Members* with bridging as required and with ends firestopped. For 2 hr fire-rated floor- LOOK FOR THE UL MARK ON PBODUCT UL/cuL SYSTEI,I N0. U-L-3065 OABLE BUNDLE THRIUGH l-HR, 0R e-!LIYPSUM VALL ASSEMBLY F-RATING = l-HR. ER Z-HR, T-RATING = 0-HR. FRENT VIEV---.------_-SECTII]N A-A -v- 2a alO:I za o.: z !J o- ao 2a E MAXIMUM 18' I.6YPSUI,I VALL ASSE}IBLY (UL/ULC CLASSIFIED U3OO OR U4{)O SERIES) (l-HR' OR z-HR' FIRE-RATINO G-HR. SHDV$. a. <mi SXOVU, t00D STUDS T0 CUNSIST 0F NolllNAL ?' x 4'LUIIBER, STEEL STUDS T0 BE l,tlNltfulf ?-t/?' ulDE S, EFTiONnL' ttAX, +, Hgttnnt Dhl.tETER STEEL PIPE SLEEVE (ScHEIIULE 40 0R HEAVIER) (SEE NOTE NB. 4 BELOV). 4, CABLE BUNDLE TO CBNSIST tlF ANY CE}IBINATION BF THE FOLLOVING I A, l,lAxlllull 7/c N0. 1? AvG CA8LE, B. I'IAXIIIIUIII 25 PAIR NO, E4 AVG TELEPHONE CABLE. C. RG 59 CI]AXIAL CABLE. D. }IAXIIIU}I 3/C NO. 14 AVG I.IETAL-CLAI} CABLE. E, l'lAxll,lulr{ e/c N0, I Av6 |IiETAL-CLAD CA8LE, F, I,IAXII,IUII 5/8 DIAI,IETER FIBTR-OPTIC CABLE. 5, itNll,tuf s/g; DEpTH HILTI Fs-oNE INTUI,IEScENT FIRESTSP SEALANT, cP 60ls ELAsTOl'lERIc FIRESTOP SEALANT, llR CP 606 FLEXIELE FIRESTEP SEALANT' 6, SEE NOTE Ntl. 4 BELOV, N[TES r l, lfAXlllUl,l SIZE 0F OPENING = 4-l/?', 2, ANNULAR SPACE = lllNll'lul'l 1/4', l'lAxlltlult'l 3/4', 3. CABLES TIl FILL I'IAXIIIIUI,I 452 OF CROSS-SECTIONAL AREA tlF OPENING. +. STE* SLEEVE },IAY BE FLUSH VITH VALL SURFACE OR EXTEND tJP TO 18'BEYONI) VALL SURFACE. VHEN SLEEVE IS EXTENIIEII BEYOND ONE tlR SOTH SIDES OF VALL, Api[v ittttlUlt ye, BEAD HILTI Fs-oNE INTU]IESCENT FIRESToP SEALANT, CP 6015 TUSTOUENIC FIRESTEP SEALNT, IlR CP 60IS FLEXIBLE FIRESTI]P SEALANT TO VALL/SLEEVE INTERFACE, tnstallation lnstructions for UL N0. W13065 STEP 1 pREPARATION:All surfaces must be clean, sound, dry and frost free prior t0 application of firestopping materials STEP 2 FIRESTOP SEALANT:Apply the required depth 0f Firestop Sealant in the aonulus, flush with b0th sides of wall or end of external sleeve. seatant witl putty t<nlfeio pusn it in plac'e and smootli the surtace. Leave completed seal undisturbed for 48 hours. 216 E[E[. Sryrrrg tryes through innovation & education I Hilti Firestop Guide 2003-2004 I 1'800-879-8000 I www.us hil O 2004 FIBE RESISTANCE DlREcroRY j THROUGH.PENETRATION FIBESTOP SYSTEMS System No. W-L-3063 F Rating - I and 2 Hr (See ltem 1) T Rating - 1 and 1-1/2 Hr (See Item 1) l. Wall Assemblv - The I or 2 hr fire-rated evosum wallboard/stud wall assemblv'shall be constructed of the mTtLrials and in the marner soecified in the individual U300 or U400 Series Wall and partition Designs in the UL Fire Resistance Directory and shall incl'ude the fol- lowing construction features: A. Studs - Wall framing may consist of either wood studs or steel charurel studs. Wood s-tudi kr consist of nom 2 bv 4 in. lumber soaccd 16 in. OC. Steel stucls to be min 2-1,/2 in 'wide and spaced riax 24 in. OC. B. Gypsum Board* - 5/8 in. thick 4 ft wide with square or tapered edgis. The gypsum wallboard type, thickness, nuinber of layers, fas'lener typi, ind sheet orientaliirn shall be as as specified in the lnqlvrquar UJUU or u*uu )enes L,reslqn m tne uL flre l(esEtance Directory. Max diam of opening is 1f2 in. The houily F and T Ratinis of ihe fircstop arc dcpcndcnt upon thc hourly fir6 rating of the ivall assembly in whicli it it inst;lled as shown in the table: :ot'l- drr-j rbcr lrc ot fas- 'indr. 8)-P' thi.k the vall )ro,('(t the rd on ,utsidt : diam :l Lting of Wall Hf t F Ratins Hr t 11?g "'11 2. Cables - Max 2/C (with ground) - 12 AWG (or smaller) polyvinyl chkrride insulated and iacketed nonmetallic sheathed cable. Oni ca6le to be centered within the firestop system. A nom annular space of 1/4 in. is required within thc fircstoi slstem. Cable to be rigidly supported on both'sides of wall assemblv' ..1. Fill, Void or Cavity Material; - Sealant - ln 2 hr fire-rated assem- blies,min l-1l4 in. thickness of fill material applied within the annulus on both surfaces of wall. Additional fill mateiibl to be installed such that a min 1/2 in. thick crown is formed around the penetrating item and lapping 1/2 in. beyond the peripherv of the openine. In I hr fire- rated isseri'blies. min 5/8 in. thiiknass oi fill mareiial aiolied withirr the annulus, flush with both surfaces of wall. Additional li[ material to be installed such that a min 1 in. thick crown is formed around the penetratinq item and lappinq a min 1/2 in. beyond the periphery.. ISOTATEK INTE.{NATIONAL _TvDe i 'Beadng the UL Classification Mark Svstem No. W-L-3054 F Rating - 1 and 2 Hr (See ttem 1) TRating-0Hr maller) under a smaller) :ket smaller) t a iacket ckness perma- roard st : annular fill mate of wall to the eve on ,etween th sides -:| '1,ffi)ry/ful I Wall Assembly - The I or 2 hr fire-rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner soecified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the fol- lowing construction features: A. Studs - Wall framing may consist of either wood studs or steel channel studs. Wood ituds to consist of nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min2-1/2 in.-wide and sbaced max 24 in. ()C . B. Gypsum Board* - 5/8 in. thick 4 ft wide with square or tapered edjes. Ihe gypsum wallboard type, thickness, nurirber of layers, e rated LOOK FOR THE UL MARK ON PRODUCT THBOUGH.PENETRATIONFIRESTOPSYSTEMS(XHEZ) 3313 fastener wDe and sheet orientation shall be as soecified in the individua'l'U30o or U400 Series Desisns in th" 0L Fir" Resistance Directory. Max diam of opening is 3in. The hourly F and T Ratings of the firestop system is equal to the hourlv fire ratins of the wall assemblv in which it is installed. 2. Cables - Aqqreqate iross-sectional arca ol thc opcning to bc max 40 percent of thi-crois-sectional area of the opening.'Cablds to be rigidly supDorted on both sides of wall assemblv Anv combination of the fol- lowing types and sizes of copper conducior cables may be used: A. Max 50 pair No. 24 AWG (or smaller) polyvinyl chloride (PVC) insulated and jacketed telephone cable. B. Max 2/C (with qround) - 12 AWG (or smaller) PVC insulateo and iacketed noimetallic sheathed cable. 3. Firestop System - The fircstop systcm shall consist of the following: A. P-ackine Material - Mi 7l8 in. thickness of min 4 pcf minerar wool bitt insulation firmly packed into openrng as a permanent forrn. Packins material to'be forced into ihterstices of cable qrou to max exteni possible. Packing material to be recessed fronibot surfaces of wall as rcouircd tolccommodate the reouired thick- ness of fill matedal. B. Fill, Void or Cavitv Material* - Sealant - ln 2 hr fire-rated assemblies, min 1,/2 in. thickness of fill material applied within the annulus on both surface..; of wall. Fill material tb be forceo into interstices of cable sroup to max extent possible. Additional fill matcrial to bc installEd such that a min 174 in. thick crown u formed around the cable bundle. In t hr firc-rated assemblies, min 3/8 in. thickness of fill material applied within the annulus on both surfaces of wall. Fill material i<i be forced into interstices of cable group to max extent possrble. Additional material hr be installed3ucli that a min 3/8in. thick crown is formed around the cable bundle. ISOLATEK INTERNATIONAL -TvDe I.Bearing the tit. Classification Mark System No. W-L-3065 F Ratings - 1 and 2 Hr (See ltem 1) TRatins-0Hr IB :-.-.' . ,2' 'A SECTION A-A 1. Wall Assembly - The 1 or 2 fire-rated gypsum wallboard/stud wall assembly shall be constmcted of the matiiials and in the manner speci- fied in the individual U300 or U400 Series Wall and Partition Desieins in thc UL Fire Resistance Directory and shall include the following con- struction fcaturcs: A. Studs - Wall framing may consist of cithcr wood studs or stecl channel studs. Wood studs to consist of nom 2 bv 4 in. lumber spaced 16 in. OC. Steel studs to be min2-1/2 in 1 wide and sbactd max 24 in, OC. B. Cypsum Board* - Nom 5/8 in. thick gypsum wallboard. with squire or tapered edges. The gypsum viillboard typc, thickncss. nirmber of liyers, faslener tvpi-ind sheet orientati6n shall be as specified in the individual U500 o! U400 Series Designs in the UL fire Resistance Direckrry,. Mar diam of opening is 4 in. The F Rating of the firestop'system is equal io the fire rating of the wall assembly. 2. Metallic Sleeve - (Optional) - Nom 4 in. diam (or smaller) steel electrical metallic tubing (EMT) or Schcdr.rlc 5 (or hcavier) steel pipc or min 0.016 in. thick (28 MSG) galv steel sleeve cast into wall assehbly with ioint comDound and installed flush with wall surfaces. When Schedule 5 ste6l pipe or EMT is used, sleeve may extend up to 18 in. bevond the wall ltirfaces. 3. Cibles - Aggrcgate cross-sectional area of cable in opening to be max 45 percent of the cross-sectional area of the opening. The annular space between the cable bundle and the periphery of the opening to be min 1/4 in. to max 3/4 in. Cables to be ridigly iupported on biith sides of the wall assembly. Any combination of [h'e follbwing tvpes and sizes of copper conductoi cabfes mav be used:'4. MaxT /C No. 12 AWd with polvvinvl chloride (PvC) insulation and jacket. B. Max 25 pair No. 24 AWC telephone cnble with l'VC insulation and iacket. C. Type RG/U coaxial cable with folvethvlene (PE) insulation and J04 FIRE RESISTANCE DIREoTOBY 3314 THROUGH.PENETRATION FIRESTOP SYSTEMS (XHEZ) PVC iacket having a max outside diameter of '.4 in D. Multiplc fiber optical communication cable iacketed with PVC and hivine a mix OD of 5/8 in. E. Through P'enetrating Products. - Max three copper conductor No. 8 AWG .Metal-Clad Cable+ AFC CABLE SYSTEMS INC F. Max 3/C (with ground)(or smaller) No 8 AWG copper conduc- tor cable with PVC insuldtion and jacketinS 4. Fill, Void or Cavity Material* - Sealant Fill material aPPlied within the annulus, flush with each end of the steel sleeve or wall surface. Fill material installed symmetrically on both sides of the wall. A min 5/8 in, thickness of seaiant is required for the 1 or 2 hr F t{ating . An.addi- tional 1/2 in. diam bead of fill material shall be applied around the Derimeter of sleeve on both sides of the wall when sleeve extends bevond surface of wall.- HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC - CP601S, CP606 or FS-One Sealant tBearine the UL Classification Mark- System No' W-L-3O67 F Ratings - 1 and 2 Hr (See Item 1 and 3) T Ratings - 0 and U2 Hr (See ltem 1.) L Rating at Ambient - Less Than 1 CFM/sq ft L Rating at 400 F- 3 CFM/sq ft (t ^) .rt\ sEcTroN A-4 1. Wall Assembly - The I or 2 Iu fire rated gypsum wallboard/stud wall assemblv shall be constructed of the materials and in the manner specified in tire individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the fol- Iowins construction teaturesi A. Studs- Wall framing may consist oI either wood studs or steel chamel studs. Wood studs to consist oI nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min 3-L/2 in widc and spaced max 24 rn. OC. B. Gypsum Board* - Thickness, type, number of layers and fasten- eri as requircd in the individual Wall and Partition Design. Max diam of opening is 4 h. The hourlv F Ratins of the firestop system is equal to the hourly fire rahrg of (he rvall issembly in ;hrlh it is installed. The hr-rurll T Ratins is 0 hr for I hr rated assemblies and 1/2 hr for 2 fu assemolles. 2. Cables - ASgregate cross-sectional area of cables in opening to be max 37 percent of the aggregJtc cross.secftonal urca of the opening Annulai space between cablis and edge of opening shall be min 0 in (point contact) to max 2-1l2 in. SeP.lration between cablcs shali he min i/8 ir,. C"bl"t to be rigidly suppoited on both sides of wall assembly Any combination of the (ollowing types and sizes of coPPer or alumi- num conductor cables mav be used: A. Max 100 pair No. 24 AWG cables with polyvinyl chloride (PVC) insulation and iacket. B, Max 3/C No. 2 AWC polyvinyl chloride (PVC) iacketed alumi- num ctad cable with ciosilinl<ed polvcthvlene IXLPE) irsulation C. Mar 2/C No. 14 AWC poll'vinyl ;il6ride (PVC) jacketed alumi- num clad cable with cr6ss-linkid polvethvlene (XLPE) insulation. 3. Fill, Void or Cavity Material* - Sealant - MII thickness of 5/8 in. and 1-114 in. of sealart for 1 and 2 hr rated wall asssemblies, respec- tivelv applied within annulus between cables and between cables and perl|leiv r.rf opening, flush with both surfaces of wall assembly. At the boint conta.t lbcation between iables and gypsum wallboard, a min l/2 in. diam bead o( scalant shall be applied at the cable/wallboard interface on both surfaces of wall assemblv, NUCO INC -Self Seal CC-2IJ0 'Bearine the UL Classification MarL LOOK FOR THE UL MARK ON PRODUCT THROUGH.PENETRANOil fBES'TOP SYSTEMS Systern'No. W-L-3058 FRating-2Hr TRating-0Hr I ;l:.-,::. ,fr'*',t , ':-: .-/::. ' -i--l: 'A srcriol l-,r Wall Assembly- The fire-rated gypsum wallboard/stud wll blv shall be constructed of the materials and in the manner sPl the irdividual U300 or U400 Series Wall and Partition Designs UL Fire Resistance Directory and shall include the following tion features: A. Studs - Wall framing may consist of either wood studs channel studs. Wood studs to consist of nom 2 by 4 in. h spaced 16 in. OC. Steel studs to be min 3-5/8 in wide spaced ma\ 24 in. OC. Gvosum Board* - Two layers of nom 5/8 in thick gB. Gvpsum Board* - Two layers of nom 5/8 in thick *ifiboard. as soecified in the individual Wall and Pr PVC jacket. Firestop System - The firestop system shall consist of the fol n. Firedtop Device* - Thrc'adbd steel sleeve halves incorp split nJts and split washers srTed to fit the specific diamsplt nuts and splrt washers srzed to llt tne sPeclnc qran opening. Devicd shall be installed around cables in accc rnlith the accompanvine install,rtion instructiuns. Dcvice in nom 1,2 and 4 i'n. rizes. Max diam of opening in wdin nom 1,2 and 4 in. sizes. Max diam of opening in r and 4 in. size devices arc 1-1/ 4,2-7 / L6 and 4-1 /2 in., tlYclv.- UNIQUE FIRE STOP PRODUCTS INC -SplitB. tacking Miterial - Min I in. thickness of min 4.0 pcf mirr wool bttt insulation firmlv oacked into Split Slceve as a pet npnt form Packino materiaf to be recessed from each end o{nent form. Packins materiaf to be recessed from each end Sleevc as required-to accommodate the required thickness b Irf s material. C. Fill, Void or Cavity Material* - Caulk or Putty - Min I thicknes; of fill miterral applied within the Split Sleeve. flt 3M COMPANY -CP 25WB+ Caulk, Ml'S-2+ Putty *Bearine. lhe UI Classi[ic.ltion Mark- System No. W-L'3O7'[ F Ratinqs - 1 and 2 Hr (See ltem 1) T Ratines'- 1/4 and 3/4 Hr (See ltem 1) L Rating At-Ambient - Less Than 1 CFNt/Sq Ft L Rating At 400 F - 4 CFM/Sq Ft with both cnds. th; individual U300 or U400 Series Wall and Partition Desigrs in 1. Wall Assembly - The fire-ratcd gypsum waUboard/stud wall bly shall be co'nstructed-of^the mat6rial.s and in [he. manner spe FRONT VIEV n <-l w A lnstuctions for UL N0. WL307l throughinnovation&education I Hilti FirestopGuide2003-2004 | 1-800-8?9-8{X,0 | www.us.hilti.com ETffn. UL,/cUL SYSTEM NE, V13071 CABLES THRI]U6H l-HR. I]R z-HR. GYPSUM VALL ASSEMBLY F RATING = l-lR, tR Z-HR T RATIItr = l/{ lR. R 3/4 HR. L RATING AT AI,IBIENT = LESS THN I CFil/S0. FT, L RATITE AT 400'F = 4 CFlt/SO, FT, SECTION A-A------ I. GYPSUI.I VALL ASSEI{BLY (UL/II-C CLASSIFIE! U3OO t]R U4OO SERIES) (I-HR OR z-Ifr. NRE-RATINO (z-HR. SHIVIO. 2. I{AXIITJI.I 3/C (+ TfiND) NIl. 2/O AvG ALUI,III{J}I llR COPPER sER 0ABLE VITH PVc INU-ATIll.l OIAX, OTY, = 2) 3 HILTI FS-IilE INTUI,IESCENT FIRESTOP SEALNTI A }IINII,III,I 5/8' IEPTH, FOR A I-HR. FIRE-RATING B I,IT.IIiII}I I-II.,I' DEPTH, FOR A A-HR, FIRE-RATIIfi. N0TES r t llAXIruH DIAI,IETER 0F 0PENIIS = 3,i 2, ANM,LAR SPACE = lllNlruil ye,, ilAxll,tult l-ile,, All sudaces must be clean, sound, dry and frost free pri0r t0 application of firestopping materials. I9l^llH!I:{qp]tth,e requrred depth of .Firestop Sealant withrn the annulus 0n both sides of watt. Tool wirh a puny srdaces. Leave completed seal undisturbed for 48 hours. oi F. J knife until flush with z oo(:c) =<.) E -z : 7 =a PVC rcior onduc- vithin ace. Fill n )/d n addi- the ds ;tud :rannet cn re fol- Jr steel mber 1 I fasten- r. Max b,, Erly fire purly T for 2 hr ,, tbe hg t0in. ,rb" *in totbly. alumi- {PVC) l. Fr i I ir E.UL MABK ON PRODUCT LOOK FOR THE UL M' : RESISTANCE DIRECTORY THROUGH-PENETRAT|ON F|RESTOP SVSTEMS (XHE4, System No. W-L-3068 FRating-2Hr TRating-0Hl 2OO4 FIRER:! li;1ff,nf,"r." Dtueciory and shall include the following construc_ A, S.tuds - Wall framing may consist of either wood studs or steelchannel shrds. Wood s"tudjto consi"t "i *; ,;;-4;l;;",spaced 16 in. Oc. steel sruds to be "*, z-i7zl. _a" ria"- sfaced max 24 in. OC.6. Gypsum Board+- 5/g h. tlLick, 4,ft wide.with sguare or tap_ ff::1 ".1q::: rhe gypsum.waub,,,,r ryp;ih;i;;; ,ii,ilji "riil1i'Tii:T",Y"fi'"Xtt;.1e.91 9ng1qii:tn.slratt .r" is ifeiiriea in J rn. The hourly F,"tir.rn 1t;".T91ljt:ign Max diam ofopening is h".tty'-fi;;;i;;#'-E or-tne luestoP system is equaf to the Ih"hle;;,i.rR;?,;;;i,fl [::ff il3ir,.iiyi"rti;!:'lll,"l;, Ffi liftt"?',#"f"""r,'#semulv in wtrictr it i" il"i"ri"i. fr,l ii".r!, " ^,., l"ll assimblies, resplcriu"jf, it v+ *a aa hr for 1 and 2 hr ratei 'F,"fl *ff :"trJ;if; ilj,T"yi;ili)ft ",d,ryfi iff il*:EJbi".?I-bedtidll, supported on both siqes or w_all assembly. The arurular space ,:.Xffi_rff.**, and the periphery of openins ,6.11 u"i,i,iiJy'in. 1 IIJIY:i1 or Caviry Materiat+ _,Seatanr_ tnsrallcd ro completety fill .*Oo.***u." Oetween the cabjes and gypsum rv"UL"ra'."^'idtf, HI.LTI CONSTRUCTION CHEMTCALS, Drv oF-u""'*, ilttll'!':,*:1,ff ",#li"' System No. W_L-3072 F Ratings__ I ard 2 Hr (See ltem 1)T Raring _ U2 Hr i. Walt Assembty-..The I or 2 tu o,*lrnTffi"- wallboard/studwa.u assembly shall. bc constructcd of the miiirials "";;ld,;;;..descdbcd in the_individual U300 or U400 Series Wall o. parito.i.-.uesign in the uL- Fire Resistance uit tory iniih"ii'i^.rriJt?i"ur*-lng construction feahues: Ir - l, 1..;:1.--- 1':lo ol\1 j'':,..{' i I :i,l' Wall Assembly - The fue-rated gypsum watlboard/stud wall asser bly sha-tl be constructed oI the materials and in the manncr specified the individual U300 or U400 Series Wall and Partition Desisns in the. UL Fire Resistance Directory and shall include the followin! construc. tion features: spaced 16 in. OC. Steel studs to be min 3-5/8 in. wide and A. Studs - Wall framhg may consist of either wood studs or st€ channel studs. Wood itudi to consist of nom 2 by 4 in. lumber 1. Wall-Aslembly- The fue-rated gypsr,rm wallboard/stud wall blv shall be constructed of the maierials and h the manner sp thi, individual U300 or U400 Series Wal.l and Partition Desie s with the accompanying installntion instructions. Device in nom l, 2 and 4 iir. sizes. Max diam oI oDenine in waur nurn l, z dn(r + rn. slzes. vrax qlam ol operung ur wall and.4 in. size devices are 1-l /4. 2-z /16 and 4-1n n., 16 nvely. UNIQUE FIRE STOP PRODUCTS INC -Split Sl B. Packing Materia!- _Mir1 1 in. _thickness of min 4b pcf wool batt iruulation firmlv packed into SDlit Sleeve 'as a nent form. Packine material to be recesse'd from each en Sleeve as required to accommodate the required thickness matenal. C. Fill, Void ol Cavity Material* - Caulk or Putty- Min 1 thickness of fiIl material applied within the Sp[i Sleeve, flr with both ends. 3M COMPAIIY -CP 25WB+ Caulk, MPg2+ Puttv-Bearing the UL Classification Mark System No. W-L-3071 F Ratings - 1 and 2 Hr (See Item 1) T Ratings - 714 and 3/4 Hr (See |tem 1) L Rating At Ambient - Less Than 1 CFM/Sq Ft L Rating At 400 F - 4 CFIWSq Fr ^ .T*;ffji ffTfg,f;rt :"-tst oI either wood studs or steel :f ffi jillrr"f, ,'JA;ft 1,".'f ,:"ff ''#fi 2',"1'*1ii"'"T*' B. Gypsum Board* - 5/g in. l *ii,j:d.:g;;,:n"#!illlji6,i,[T,,$?.Tnll,iXH,*"1i.*,., fir""f;aiiilili',Htr :lfih8"J orientardri,n.n -u" iiip*inli u flT"""'ttrFfl"Ytiflif Hf,i{il?iirii,'lr,"o'"0":": *:::$itr;"1-:!$f *ii.l'i{-ttr*T$.q:tT:r_":iil'J"'" ift:'ffiH':?iT,l"iff?H.:t"ff[ f'.sth or sreeve.to be equat t, ihe s_legye prole-c1 2 in. beyond "".h ,id1;i[X',ff;:lled, the ends of the g."f ,rHr,.F:ifir'[?;3i$gF,t{;ril]*i&"1#,T{1i3.?t1n"..",area ot.cable to be max 25 perceni r ilg: -g_"bf, to ue riggry suipo;;i"j,'i"itT,'Jtr.j',"** i::L"ff:*"'f 'H.'t!"L;,"#,1;",6';n:,n*t j;"*"fu,"1i1.{{i- Htii ?lx-tr$:?+i ruH?:i:"l Tii""f; runs i,rd"h:.to max extent possible. packir lHjT?''",'#j,[ j:.'"*"rillff ffi '?':ini*'"?i,T'1'j"fi .?s B. Fill,.Void or Cavity Material* i*!m;ruif ##1til"i*1$i;t:',^"r$,:"$:ff : lllx^:x^telj rys:ible. A min l./2 in. thict Ueaa sr,aU Ue'ufpiiii aime steer sreeve/gypsum wallboard interface on Uom "ui6cei J' W R GRACE & CO. CONN CONSTRUCTION PRODUCTS DIV _FS 1900 Sealanr spaced max 24 in. OC. B. Gypsum Board* - Two Iayers ol nom 5/8 in. thick gvpsum waLlboard, as specified in the individual Wall and Paitlfion Desisn, Cables - Aggregate cross-sectional area of cables in Solit Sleeve min 8 percen'lio -max 36 pcrcent of the asffesate cross]sectional r the Split Sleeve. Cables to be rigidly supiSrtid on both sides of r(ne )prrr Jreeve. LaDles ro De ngldly supported on both sides ( assembly. Any_ combination of tl-re following types and sizes ot conductor cable mav be usedr A. Max 350 kcmil sinqle conductor Type XHHW power cibles: cross-linked polyeihylene (XLPE) Gsulation. B. Max 150 Dair N6. 2dAWC conductor telecommuni.etion c)ts. Max 150 pair No. 24 AWG conductor telecorrununication cat _ polyvinyf chloride (PVC) insulation and jacket materials. C. Mal Nci. t2 AWG multrconductor Type fC power and contr, 99!!e9; Jype XHHW conductors XLPE insulition with XLPEr PVC iacket. Firestop System - Thc lirestop systcm shall consist of the A. Firestop Device* - Thniadbd steel sleeve halves inc, split nuts and split washers sized to fit ihe specific dia; opening. Device shall be installed around cables in accot SECIION A-A 2004 F|RE RESTSTANCE DTRECTORY o for the side of the outlet box against the stud) and completely seal aqainstthe stud withrn the stud caviry An additional 3/4 in. b;lt of -punv D;dmatenal used to plug the end of each elechical metallic tube'or c6riduit atlts connection to the box. When moldable putty pad outlet box protective matedal is used on boxes on both sides of'wall is directed, the horizontal separation between boxes on opposite sides of the wall may be less than 24rn. provrded that the boxes are not installed back to back- W R GRACE & CO - CONN CONSTRUCTION PRODUCTS R11635 DIV 52 WHITTEMORE AVE, CAMBRIDGE MA O2I4O . ,FlameSafe P-.utry Pads for use with max 4 by 3-3/ 4 by 3 in. deep UL Listedr\{onmera lc (Juflet ttoxes manutacfured by Carlon Electrical pioducts andmade from polyvinyl chloride and bearing a 2 hr rating under tt" ;OuO.t Boxes;nd Fittiirgs elassilied for Fire Resis"tarce,, .rios"?v i" th"'iir" n.ri"tdrce lJueclory. Pulty pads and boxes for use in 2 hr fir? rited eypsum boardwau assembtjes tramed with min 3-1l2 in. deep wood studs a_id tonstructed as specified in the individual U300 Series Wall aid partition Designs in the FireKeslsrance urectory. Uuflet box secued to wood stud by means of two nailine tabs ln conJunctron with nails supptied with tie outlet box. Min | /g in. thjc[moloable putty pnds are to be instdlled to completely cover the exterror surlaces ot the outlet bor (cxccpl for thc sidc of the outletbox agdiJrst the stud) induding nailing tabs and completely seal against the stud within the stud caviry. An additional 1/8 in. thickness of putty to be formed around the end of each nonmetallic sheated cable at its conneciion to the box and to extend a mininum of 1/2 in. hom the box onto the nonmetallic sheated cable within the stud cavity. Boxes installed with plastic cover plates. When rnoldable putty pad outlet box protective matedal is used on boxes on both sides of wirll asdirected, the horizontal separation between outlet boxes on opposite sides ofthe wall may be less than 24 in. provided that the boxes ai6 noi installed back-to-back. - !yp9 nn Putg Pads Ior use with max 4 by 4 in. flush device UL ListedMetauic Outlet Boxes installed with steel covef plates in 1 ard 2 hr fhe ratedglpsum wallboard wall assemblies framed with i.ninimum 3-5/g in. wide steelstuds and constructed as specified in the individual U400 Series Wall andl'arhhon l)esigns in the Fire Resistance Directory. Min l/8 in. thick moldableputty pads.rre to be.installed to completely cover the exterior surfaces oI theouttet, bo), (ercepl .lor Lhe side oI the outlct box against the stud) andcompletely.seal against the siud within the stud cavity.-,An additional 1/g in,of pu-tty tobe formed around the connector securing tfre end of each electricalmetallrc tube or conduit to the box. When molda-ble putty pad outlet box protectivc. material used on boxes on both sides of wiU G js directetl, thehorzontal separation between outlet boxes on opposite sides of Lhe wal.l mavbe less than 24 in. provided that thc boxes arc riot instaled back_to_back- ' 1090 LOOK FOR THE UL MARK ON PRODUCT g/01 I'UE 0g:59 FAI S?0Z451O 15o conuerclal De818n,ug;:z xkler & ooe \J System No. W-L-|OS1 F Rofia$ - I oad 2 Hr (Sce ficrts t cnd S)TRdim-0ftt tutttg At ffi --Lcgs lhon t Cillh RtffotqA{nF-lCillhFt SEfinfl r-A_ L Udl Asanbly -: Thg I or 2 hr firc-mtad gypsum rollbmnr^ff fl*l*$.m1fi-*rtiu,p1;vrsdffi ,ffi ffi##,*nffi.A 5tr6.-- woll frqning moy-onr*st & d!il6; silb or decf *onncf rtr6. kod $tu6 bconsist of ,rsn 2 by 4 in. tunser. spoced 16 in, oc- it g +dr b bc rfin 2-r/2 in, ri& .ndsp.c^d mor 24 in. 6. ftlre g.r! ituds ore u"o ono lr'r dicn of opcnng a.iro trs ritttr *rtud covfty, he openirn sttor bc_tumcd ;;ffi;;u Jrnslto_of drrr-$ud rniloied brtrcar tjrclatiod stu& ond scr*f'd*d to_uru rtrur riuau-otL.r, *a lhc kon.d opcni,iE i,r thc rcilch.lt h 4 to 6 h' rider qnd.1 to g r,t r'gl.ifii ri'iqrr;t th;fi,rrrfr #H'",,a, ,,ot,rt*n rre penerrotirs ilem.ie a*ura n tdrpJird ;", b l-n, ;ffi"t?#lio** u,.pcldrutng ilem ond fre komrilg ot oll four iOes. " - - B' Gpsrm Boordr -- 5/E in-th'nk +.ft iide *i*rsguore-or.topuF. $*the-grp*um bo.rd bpquridoe$, number of ri1'ers, t d";r #;"il"j*J"oH,r.- rn.r E 08 sccfird in u,u indiyirmlu500 or u4fl) serieo Desiyr in tre uL'Fira n*pt i.r olr*try. lt cm 0t opc'r,g b J2-r/1 h,1" $ryl rhd roll$. llox dom of operhg t f+_|i1..'r"r rcod srud mls.lha F Rotiu of the firestop sptern'is c,{,oi to nJin rc*,rg ot tio ro* or*m.ry ftproe€Ed by Hrllt, hr. Cd tlsy dUrdcffitcD Loborotorisc, tnc, 0.ccmber 1. 2m2 'tr" 15o9702t510 Systern No. t-L-1054 F Rffigs - 1 ond 2 Hr (Sec fim t dd 0IRqtrtg-0tlt RoBtg * ffitunt - tcss lhcr | ffiAq R LtuetgAt{nF-4CnlSR 2 lhrc4h-Penetrunts -- One metollic pipe, conduit or tubing to bc ilrrtdbd dlha mncartdcof or 9ocgtqrytl T:Fir tlre ftrc0t111.-?,B!l.l. lho^onnutor spoce ehoil bs dn 0 tn b mox 2_1h 11" Hpe mqbe instqlhd rilh conlinuors poin{.corrtoct. Pipe, corduit o tub'nog "ry lc lnrtiottcl of on'i,nglu 1rt -9rd6, trn l.! $reg-trog pencndkuror. Fpa, cdnduit w tubing to tic rtiutl a,piidri;-bd6 ddls of ,olo'sanbly' Ihe tuhrhg ffi o'd sircs of met'fic prpee, iontuib d trforw';Ev be-d;- ! lteel_fpe -- lbm J0 in diom (or smollcr) Sshsdute 10 (or hooyiodftoipipa - B. hm Ppr -- ilnn J0 irr dhrn (or moller) oost or drcdli tor, pd C. Co.rduit -- lhm 4 in dhm (or smoller) shol ctectrir:ol rnemnc i6ing or 6 in. dorl Ssd cdduitl.W Trbitg - mrn 6 irr- dom (or snrofier] Type t (or heoricr],fo- tli,"_. _ -E Oopper Ppe -- t{om 6 in. diom (or emotbr) rquhr (or trea,bd ;d phs - 3.ril, luofr.htl Tofrrd'-- sedmt -- rtin ile-in. ftich.s, 'f'nr ilob,id oDDtud $fiin h,onrultn' fldt rith both surfoceg of roll. At the poirt or continuous *rt""t 6;"td'diffi pb" 6ndl$' : "m 1/2 rl" drnr. b.d of frfi nrtarist shotf h opplfud ot $c pp6 roll .nhrisq m boffr rrrfoo*of rol . ilLll mt$zucn0N $EltcAs, uv tr HtIl ltl0 -- F5-0ne Seqlont.ts{rhg t}te t[- Clossilicotion Uo* WA b, HI+ hs, Co,trry ol UndrnrihrE Lobom lorier, lnc: 0ec€m[r 1. 2m2 ,ffi"" @ oro t t t U-/cuL SYSTEI,I tfr, F-C-1059 I.|ETAL PIPE THRI]UGH I-HR. ER E-HR, Vtlt]D FLt]t]R F-RATING = l-HR 0R ?-tR T-RATING = 0-HR,0R I/Z-HR. TOP VIEV zI -oo z, t =oo zak-I. V_OEII FLOOR/CEILING AS-SEIIILY ruL/ULC CLASSIFIEII LsM SERIE$ O-HR. IR 2-I{R,FNE-RATI}.IO (z-HR SHOVD. A LU,IEER OR PLYVITD SUBFLMR VNH FII{ISH FLOM tF LU{BER, PLYVNOD, OR FLIORTI]PPII{G I,IIXNNE, 3 PEIfiIRATING ITEIi T0 BE mE 0F TtE F0LL0VI}S r A. IIAXI}IUII 6' NO}IINAL IIAIIETER STEET PIPi (SCIfl)til-E 10 OR HEAVIE$,!, llAXIl,tU,t 6, NBI,INAL I]IAffiTER CAST IR0N-PIiE. C. I,IAXIruH 6'NI]IIINAL DIAIfrTER STEEL CINIIJiT, D. I,IAXI}IU}I 4' NO}IINAL DIA},IETER EI,IT.. ._ _E, ilAXIilUlt 2' N0ilINAL DIAHETER FLEXIELE STEEL CtililtutT. 1, fqfuu! 3/4, DEPTH HrLTr FS-oNE rNTUilEScaNi iriEsroF-SeAr_em,5, HITTI FS-IINE INTUIIESCENT FIRESTI]P SiCTEI[i, - A, IIINII{U}I 5/8' DEPTH OF SEALNT FOR A I-HR, FIRE-RATING, B. lftNlilul't t-t/4, DE9TH 0F SEALANT roR A z_HR. iine:nnimc. Eo :E<) u.J F(5z, E F lnstallation lnstructions tor llL N0. FCl05g STEP 1 PREPAMTION:All surfaces must be clean, sound, dry and frost free prior t0 application 0f firestopping materiats. STEP 2 llllsryf qEA{ITi.Apply the required depth.of Ftrestop Seatant,in the annutar space between the pipe and subfto6r and betlveen the pt'e andg)/psum ceiling Tool the sealant with a puttv knife to push lt in place and smootn tne surrace, leirie'borh compreiro irili ,iniiiii,iij.ci'r6i48 hours. ffi N0TES r l, l,lAxll,lutt DIAMETER EF 0PENINC = 7-S/B', 2. ANNULAR SPACE = l,fiNlltult t/4,, t4AXI4tJt4 g/4' 3. qH4SE VALL (NI]T SHEVN, OPTII]MD - TH' THROUGH PENETRANT }IAY BE RI]UTEI) THROUGH A I-HR OR A-HR, FIRE-RATID GYPSUI.I C_iAJE VA'f AiSEIirirV. - _' EE['srYing Liyes thtough innovation & education I Hitti Firestop cuide 2003-2004 | t -g00-879-E@0 I www.us.hitti.com ASSI|[|BLY d\ UL/cUL SYSIEII N0, F-A-1029 METAL PIPE THROUGH CONCRETE FLOOR I]R CDNCRETE FLOOR I]VER T,IETAL DECKING F-RATING = Z-lR, T-RATItfi = 0-HR, g GIe 6 ETOP VIEV---SECTII]N A-A'-"- A t- l. CI]NCRETE FL00R ASSEIIBLY (e-HR, FIRE-RATINO t A. LIGHTVEIGHT M NOR}IAL VUCIT CIilERETE FLOM ffiN, ?-Ilfl THICO, B. STEEL FLIm U.IIT/FL00R ASSEIIBLY - ]fiRl,lAL VEIGHT CIIIIIRETE rL0m (}lru e-il?' IHICIO OVER }IETAL IECKING. 2, PEIETRATIIS ITEJ T0 BE ENE 0F THE FII-L0VING I A. }IAXII{J}I 30' M]I,IINAL DIAIETER STEEL PIPE (SCHEDULE IO llR HEAVIER), E. I,IAXII{SI 3I'M},IINA- IIIAIIETTR CAST IRON PIPE, C, I,IANruil 6' MHIML DIAIf,IER COPPER PIPE. IL tlAxll,lul,l 6' Nlllln$L IIIAIIETER STEEL CIINIIUIT, E, I,IAXIruil 4' NIilIINAL IIIA}fiTER EiIT, 3 ilINNUH V2' WPIH HILTI FS-Iil{E INTTJIIESCENT FIRESTIIP SEALANT. 1. I,IINII.IIJI{ I/4' BEAD HILTI FS-E{E INTI'IESCENT FNESTIIP SEALA}IT AT PI]INT IX,I CONTACT. N0TES r L l{Axlruil DIAI,IETER llF 0PENING = 30-7/8" ?, AI$[I-AR SPACE = nNInil 0', l,lAxlllL$l 7/8'' lnstructions for UL ll0. FAlng All surfaces must be cban, sound, dry and frost free prior t0 application ot firestopping materials. SEALANT:Apply the required depth of Firestop Sealant flush with the top 0f the fl0or. Tool the sealant with a putty knife to push it in place h the surface. Leave completed seal undisturbed lor 48 hours. Innovarion a eOrratil Hilti Firestop cuide 2003-2004 r r-gG0-Azs-s000Qww.us.hilti.com l=Tfn' z--']Do0c 6z (-) -z, c --t a = = @ --.1 -o t submittal Pr{ect: Archltect: General Contractor: Instal ling Contractor: Distributor (and Gontact): Western Fastnerc 2607 W. 8th Ave. Denver, CO.80204 303-534-0661 Manufacture/s Representative : Hunter & Associates, lNC. 1724Wllox Crt. Fort Collins, Go.80524 303-659-9016 (Denver) Rcctorseal - Technical Services Ph (713) 263{00l i (Eoo) 23t-3345 ut I v.r\.I+J+o - wau \rPcnug rfo[Ecu o rage r or ) CLIV.RI4546 Questions? Wall Opening Protective Materials Page Bottom Wall Opening Protective Materials Guide Information RECTORSEAL 2601 SPEI\NVICKDR HOUSTON, TX 77055 USA Metacaulk Fire Rated Putty Pads or Biostop Fire Rated Putty Pads for use with max 4by 4 in. flush device UL Listed Metallic Outlet Boxes installed with steel cover plates in I and 2hfre rated glrpsum board wall assemblies framed with min 3-ll2 in. deep wood or steel studs and constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the Fire Resistance Directory. Min 1/8 in. thick moldable putty pads are to be installed to completely cover the exterior surfaces of the outlet box (except for the side of the outlet box against the stud) and completely seal against the stud within the stud cavity. When moldable putty pad outlet box protective material is used on boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk Fire Rated PuW Pads or Biostop Fire Rated Putty Pads for use with max 2-3/16 by 3-3/4 by 2-ll/32 n. deep UL Listed Nonmetallic Outlet Boxes manufactured by Pass & Seymorn Inc. under the tradename Slater, made from polyvinyl chloride and bearing a 2 h rating under the "Outlet Boxes and Fittings Classified for Fire Resistance" category in the Fire Resistance Directory. Putfy pads and boxes for use in 2 h fire rated gypsum board wall assemblies framed with min 3-l/2 n. deep wood or steel studs and constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the Fire Resistance Directory. Outlet box secured to studs by means of mounting tab supplied with the outlet box. Min 1/8 in. thick moldable putty pads are to be installed to completely cover the exterior surfaces of the outlet box http:i/database.nl.com/cgi-binuXWtemplate/LlSEXT/IFRAME/showpage-htrnl?name :CLIV... 3/7/04 Rl4546 ul-r v -ral4)+o - walr LrDenng Ivlarcnals Yage I oI J including the side of the outlet box against the stud. Outlet boxes installed with steel or plastic cover plates. When moldable putty pad outlet box protective material is used on boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than24 in. provided that the boxes are not installed back-to-back. Metacaulk fire Rated Putfy Pads or Biostop Fire Rated Putty Pads for use with max 4 by 4 in. flush device UL Listed Metallic Outlet Boxes Installed with steel or plastic cover plates in I h fire rated gypsum board wall assemblies framed with min 3-l/2 n. deep steel studs and constructed of the materials and in the manner specified in the individual U400 Series Wall and Partition Designs in the Fire Resistance Directory. Two layers of min 1/8 in. thick moldable putfy pads are to be installed to coompletely cover the exterior surfaces of the outlet box including the side of the outlet box against the stud. Nom 1/2 in. plaster rings installed over outlet boxes. After installation of gypsum board, nom l/4 in. thickness of RectorSeal Metacaulk 1000 or Biostop 500+ Sealant, bearing the IIL Classification Marking for Fill, Void or Cavity Materials, applied between gypsum board and the plaster ring. When moldable putry pad outlet box protective material and fill material are used on boxes on both sides of wall as directed, t}re horizontal separation between outlet boxes on opposite sides of the wall may be less than24 in. provided that the boxes are not installed back-to-back. Metacaulk Box Guard or Biostop Lectra Stop Inserts for use with max 2-l/8by 4by 2-l/8 in deep. flush device UL Listed Metallic Outlet Boxes without internal clamps in 2 h fire rated gypsum board wall assemblies framed with min 3-I/2 n. deep steel studs and constructed of the materials and in the manner specified in the individual U400 Series Wall and Partition Designs in the Fire Resistance Directory. One 47 mm wide by 71 mm high insert adhered to the interior back wall of the outlet box in accordance with the installation instructions supplied with the product. Installation to comply with Article 370-16 of the National Electrical code, (NFPA 70). Outlet boxes installed with steel cover plates. When protective material is used within outlet boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk Box Guard or Biostop Lectra Stop Inserts for use with max 4 by 4 by 2- 1/8 in deep flush device UL Listed Metallic Outlet Boxes without internal clamps :rnzlv fire rated gypsum board wall assemblies framed with min 3-l/2 n. deep steel studs and constructed ofthe materials and in the manner specified in the individual U400 Series Wall and Partition Designs in the Fire Resistance Directory. One 94 mm wide by 95 mm high insert adhered to the interior back wall of the outlet box in accordance with the installation instructions supplied with the product. Installation to comply with Article 370-16 of the National Electrical Code, (I.IFPA 70). Outlet boxes installed with steel cover plates. When protective material is used within outlet boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. http://database.ul.com/cgi-bin/XYV/template/LlSEXT/lFRAME/showpage.htrnl?name:CLIY... 317/04 fTOIeCUVe o \-Ll v.lrl+J+o - walr LrDeruns ve rvlalenars rage J oI J Metacaulk Fire Rated Putty Pads or Biostop Fire Rated Putty Pads for use with max 4by 3-314 by 3 in. deep IIL Listed Nonmetallic Outlet Boxes manufactured by Carlon Electrical Products, made from polyvinyl chloride, and bearing a2lu rating under the "Outlet Boxes and Fittings Classified for Fire Resistance" category in the Fire Resistance Directory. Putty pads and boxes for use in I and 2hr fuerated gypsum board wall assemblies framed with min 3-Il2 n. deep wood studs and constructed of the materials and ;n the manner specified in the individual U300 Series Wall and Partition Designs in the Fire Resistance Directory. Outlet box secured to wood stud by means of two nailing tabs in conjunction wit nails supplied with the outlet box. Min 1/8 in. thick moldable putty pads are to be installed to completely cover the exterior surfaces of the outlet box (except for the side of the outlet box against the stud) including the nailing tab and completely seal against the stud within the stud cavity. Outlet boxes installed with steel or plastic cover plates. When moldable putty pad outlet box protective material is used on boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than24 in. provided that the boxes are not installed back-to-back. Metacaulk Box Guard or Biostop Lectra Stop Inserts for use with max 4-l/2by 8-l/2 by 1-518 in deep . flush device IIL Listed Metallic Outlet Boxes without intemal clamps in 2 ltr fire rated rypsum board wall assemblies framed with min 3-Il2 rn.deep steel studs and consfucted ofthe materials and in the manner specified in the individual U400 Series Wall and Partition Designs in the Fire Resistance Directory. Two 94 mm wide by 95 mm high inserts are evenly spaced and adhered to the interior back wall ofthe outlet box in accordance with the installation instructions supplied with the product. Installation to comply with Article 370-16 of the National Electrical Code, (NFPA 70). Min 3/4 in. deep plaster rings installed over outlet box. After installation of gypsum board, nom 1/4 in. thickness of RectorSeal Metacaulk 1000 or Biostop 500+ Sealant, bearing the UL Classification Marking for Fill, Void or Cavrty Materials, applied between the base layer of wallboard and the plaster ring. Outlet boxes installed with steel cover plates. When protective material is used within and around outlet boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk Box Guard or Biostop Lectra Stop Inserts for use with max 4by 4by l- I/2 in. deep flush device UL Listed Metallic Outlet Boxes without internal clamps in I hr fire rated gypsum board wall assemblies framed with min 3-1l2 in.deep wood studs and with max 4 by 4 by 2-l/8 in. deep flush device UL Listed Metallic Outlet Boxes without internal clamps in t hr fire rated gypsum board wall assemblies framed with min 3-112 in.deep steel studs and constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the Fire Resistance Directory. One 94 mm wide by 95 mm high insert adhered to the interior back wall of the outlet box in accordance with the installation instructions supplied with the product. Installation to comply with Article 370-16 of the National Electrical Code, (NFPA 70). Outlet boxes installed with plastic cover plates. When protective material is used within htfp://database.ul.con:/cgi-binD(Wtemplate/LlSEXT/lFRAME/showpage.htrnl?narrc:CLN... 317/04 rrorecu o u]-rv-Kl4)4o - wau qperung Matenals rage 4 ot ) outlet boxes on both sides of wall as directei, the horizontal separation between outlet boxes on opposite sides of the wall may be less than24 in. provided that the boxes are not installed back-to-back. Metacaulk Cover Guard or Bio Fireshield Firestop Gaskets for use with max 4-II/16 by 4-lI/16 in. flush device UL Listed Metallic Outlet Boxes installed with steel or plastic cover plates in 2 h fire rated gypsum board wall assemblies framed with min 3-I/2 n. deep steel studs and constructed of the materials and in the manner specified in the individual U400 Series Wall and Partition Designs in the Fire Resistance Directory. Nom Zby 4 in. or 4 by 4 in. gaskets to be installed on the inside of single gang or double gang cover plates, respectively, prior to attachment to device. Installation to comply with Article 370 ofthe National Electrical Code, (I.IFPA 70). When protective material is used within cover plates on outlet boxes on each sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than24 n. provided the boxes are not installed back-to-back. Metacaulk Cover Guard or Bio Fireshield Firestop Gaskets for use with max 4-ll/16 by 4-11116 in. flush device UL Listed Metallic Outlet Boxes installed with steel or plastic cover plates in t h fne rated gypsum board wall assemblies framed with min 3-l/2 n- deep steel studs and constructed of the materials and in the manner specified in the individual U400 Series Wall and Partition Designs in the Fire Resistance Directory. Min 4 in. thick fiberglass (min 0.5 pcf) or mineral wool (min 4.0 pcf) batt insulation is to be installed within the wall cavity. Nom 2 by 4 in. or 4 by 4 in. gaskets to be installed on the inside of single gang or double gang cover plates, respectively, prior to attachment to device. Installation to comply with Article 370 of the National Electrical Code, (I.IFPA 70)- When protective material is used within cover plates on outlet boxes on each sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than?4 in. provided the boxes are not installed back-to-back. Metacaulk Cover Guard or Bio Fireshield Firestop Gaskets , for use with max 4- 11/16by 4-11/16 in. flush device UL Listed Metallic Outlet Boxes installed with Decora style steel or plastic cover plates in t h fne rated gypsum board wall assemblies framed with min 3-l/2 n. deep steel studs and constructed of the materials and in the manner specified in the individual U400 or V400 Series Wall and Partition Designs in the Fire Resistance Directory. Min 4 in. thick fiberglass (min 0.5 pcf) or mineral wool (min 4.0 pcf) batt insulation is to be installed within the wall cavity. Nom 4 by 4 in. gaskets to be installed on the inside of double gang cover plates prior to attachment to device. Installation to comply with Article 370 of the National Electrical Code, (NFP A 70). When protective material is used within cover plates on outlet boxes on each sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than24 in. provided the boxes are not installed back-to-back. Page lo+Notice of Questiens? rrotecuve O httpJ/database.ul.com/cgi-binD(Wtemplate/LlSEXT/lFRAME/showpage.hfinl?nasrc:CLIY... 3/7104 rage J or ) Disclaimer UL Listed and Classified UL Recognized Products Certified Products Components for Canada This page and all contents are copyright @ 2004 by underwriters Laboratories Inc.@ Thg appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the IIL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look forthe Mark onttre producl UL pennits the reproduction of the material contained on tIL's Website subject to fhe following conditions: L The Guide Infonnation, Designs and/or Listings (files) must be prespnted in their entirety and in a non-misleading manner, without any manipulation of the data (or d.a*ingf). 2. The statement 'Reprinted from the Online Certifications Directory with permission fiom Underu.iiters Laboratories Inc." must appear adjacent to the exhacted material. In addition, the reprirrted material must include a .copyright notice in the following format: "Copyright @ 2004 Underwriters Laboratories Inc.@u \-!r v .^l+J.to - warr vPclturg, r.rolccuvc rvlatrflals o h@/database.ul.com/cgi-binD(YV/template/LISEXT/lFRAME/shourpage.htrnl?name:CLlY..- 3/VM January 1999 APPROVALS FOR BIO FIRESHIELD" PRODUGTS Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived from one or more of these model codes. Bio FireShield" products and systems meet the through-penetration firestopping requirements of all of these codes. Bio FireShield" has also been approved in various cities, counties and slates that have written their own code requirements which may supersede or supplement model building codes. Gitv Approvals Phoenix, Arizona Tucson, Arizona Los Angeles, Galifornia San Francisco, Califomia Minneapolis, Minnesota New York, New York Milwaukee, Wisconsin Gounty APprovals coilier, Frorida Dade, Florida Palm Beach, Florida State Aoorovals Newyork North Carolina Wisconsin Miscellaneous Approvals corp of Engineers Califomia Strate Fire Marshal General Services Administration lndustrial Risk Insurers Bio FireShield" Products are UL Classified and conform to the codes and test reouirements shown below. ASTM E 814. Fire Tests of Through-Pen€tration Fire Sbps UL 1479 . . . . Flre Tssts of Through-Pen€tsatton Fire Sbps NFPA 70 . . . Nalional Fire Protec.tlon Association National Elec.trical Code UL 723 . . . . . Standard Test Method for Surfuce Buming CharacErbtics of Building Mabrials UL 263 . . . . . Fire T€sb of Building Consfuclion and Mabrialg NFPA 255 . . . Method cf Tesling of Surbce Bumlng Characbdstics of Building Mabriets ASTM E 119 Firc Tesb sf Buitding Construcdon and MaErlals ASTM E 84 . . Surface Bumirg CharacEristics of Building Mabrials ULC CAM€1 15M . . . . Sbndad Method of Fire Tests of Firestop Systans ULC CA|I/ULC-SI01M . Stgndard Mehods of Fire Endumnce Tesb For Questions or Additional lnformation call Technical Service 1€0G231-3345 ' 1-713-263-800'l F ax I 3O0452-2824 . 1-71 3{82$813 SBCCI . . . . . Soulhem Building Code Congress Intemadonal; Shndard Building Code BOCA . . . . . Euilding fficial and Code Administators lnbmatonal; Nalimal Buildlng Code CABO . . . . . Councilof Am€rican Bullding Otrdds (coordinating agency between ICBO, SBCCI and BOCA) NBCC..... Nalional Building Code of Canada NFPA 101 . . National Fire Protectim Associalon Life Safetv Code 2601 Spenwick Orive affi::H*:T'77055'1035 TE!-EFHON E: 71 31263-8001 FAX: 713/263*7577 GNERAL CERTIFICA1E OF COMPTIANGE BIO FIRESHIELDTM FIRESTOPP. ING PRODUCTS BIO K-10+TMMORTAR BlomERMrl' r00p00sl. flLIcoNE SEALANT BIOSTOPfl BFl50+ BIOSTOP-III 500+ SEAI-AI{T BIOSTOPT!{ 7OO SPRAYASI.E MASTIC B IOSTO?'IM 750 SPRAYABI,E MASTIC BIOSTOPTM COMPOSITE SHEET BIOSTOPT}{ FIRESTOP GASKET BIOSTOPTM FIRESTOP PILOW BIOSTOPH IOINT STRIP BIO FIRESHIEI..DtM LECTRA.STOP BIOSTOPTM PIPE COI.II\R BIOSTOPTMPUTry STICKAND PUffY PAD l BIOSTOPTMWRAP STRIP ARE TESTED ACCORDING TO ONE OR MORE OF: Tlm FOII-OWING DESCRIPTION: THESE PRODUCXS STA}.IDARDS: U,L.263 -FIRE TESTS OF BUILDINC CONSTRUCflONANDMATERIALS U-L. 1479 -'FIRE TFSTS OF TI{ROUGH-PENETRAfiON FIRESTOPS UL 2079 - IESTS.FOR FIRE RESISTANCE OF BTJILDING JOINT SYSTEMS ASTM E-814 - FIRE TESTS OF]I{ROUGH-P"ENETRATION FIRESTOPS ASfi\lI E-84 - SURFACE BURNING CHARACIERISflCS OF BIJILDING MATERIALS ALL P,RODUCIS CONTAIN NO ASBESTOS OR PCB'S AND ARE CONSIDERED V.O.C. COMPLIANT. EVAACKERMAN TECHNICALDIRECTOR SUBSCRIBEDAI{D SWORNTO BEFOREME THIS :6 DAY OF NOTARY IN AND FOR THE STATE OF TEJGS COUN,TYOFHARRIS My COMMSSIO'I E(PIRES ir,tAY t,2004 MYCOMMISSION STIBILITY: Stable C€Ii|DITIONS TO AVOID: lfoDe rlIcoMPATIBItIfC (ItlAIERrAlS fO AVOfD) 3 None )o.oun. $AZARDOITS DECOUPOSITION PRODBCTS: CO, CO2 a!'d lragnentsed hydrocar.bonE. EAZARDO.ITS poIYMERIZATION: 91i11 not occu!. Sectior 11 -- ToXIcOIJogy INFoRlaTfoN OIROITTC EEAT,IH IIAZIRDS No irgredient in Ehis product, is an IARC, l{fp or OSHA LiBted carcinoEen. TOXICOI,OGY DATA Ingredieat Name Triazine T!ia(oi.[e Pbosphate Oral- -Rat LD50:N/D Inhalation-Rat:N/D caLciul Borate Ora]. -Rat. LD50r5600 nglkg Inhalatioo-Rat:N/D Poltpbo6phori c Acid oral -Itat LD50:!I/D Inhalat.ion-Ret:N/D IEodecyldipbeayl E6ter OraI -Rat LD50:N/D Iabalation-Rat:N/D Sec!.i.on 1.2 -- Ecological Inforoabion ECOIOGICAI, DATA fngredient Name friazine Triamine Phoapbate Food Cbain concentration Potential N/D IIAIERFOWIJ TOXICIT:f N/D BOD }I/D AQ@TIC TOXICITY N/D caLcium Borate Food Cbain Concerrtratioo Potentia] N/D NATERFOMJ TOXICITY !T/D BOD N/D AOTRTTC TOXTCITy ![/D Pol)rpboapholic Acid Food Cbain concentratior PoteD.tial N/D T(AfERFOIL TOXTCTTY N/D BC}D N/D AQLATIC TOXTCITY N/D Isodecyldipbenyl Ester Food Cbain Conce!.Erat.idr Potsential II/D flATERFOWL TO|I(ICTTY N/p BOD N/D AQmTTC TOXTCITY N/D SECIiON 13 -- DISPOSAIJ CONSIDERATIONS tfaate Claedification: t{on-regulated 6ol-id waate Dispoeal uetbod: 4)proved landfi.].l, nasEe from t1d6 Irroduct is not coa6idered bazardous as defined rmder tbe Regource CoD.aenration and Recovery Act (RCRA) 40 CER 261. Diapoae of ia accordance lrith Fedcral, State, and Local regulation regarding pol_lution. secEi@. 1rt - - rRANspclRTATIotv It[FoR!,rATroN DOT: t{on-Regnrlatcd OCEIAIS (Il,lDG) : Nor-Regulated AfR (IATA): Non-Regufaled tfllllS (cDrlADrA): lg@-R€gulaced sectlon 15 - - REGST,AIORT r![RCrRtrtArIOU RAq'T.A!C'RY DATA Irgrredient Nene Tliaziae rrianine PboElrbate SARA 313 tf,o ISCA Inrr€ntory Yes CERCLA RQ lVA RCRA COdE N/A ca].ciun Borate stRl 313 lto TSCA InveDtory Y6s CER,CIA RQ !5/A RCRA COdE N/A PolylihoBtriboric Acid SARA 313 [o TSCA Xnventorl. Y€s CERCIA RQ N/A RCRiA Code !r/A Isodecyldipbe[ty]- Bater seRA 3L3 No TSCA Iav€ntsoqr Yes CERCIA RQ N/A RCRA COdE !T/A o seclion 15 -- cxnl8R. IIIFORI|ATTON Tbia documE is pr€pafcd purEuant to tbe OSSA Hazard co@udieation Standard (29 cAR 1910.1200). The iaformation bereir le Eiwen in good faith, but no warranEy, €xpleEaed or lugllied i6 nadc. consulE Rectorseal f,ot further infoloatior: (713) 263 - 8001 nedical att€srtion. It in EYES I hnediateLy fl.ush with Lalge amountg of sater. IfirritatioD occura, seek nedical attenti.on. If StlALrL,OlfED: If Bwallowed, call a physician immediaiely. Only iaduce . vomiting at lbe insrruclion of a physicial. Never gj-ve anytbing by mouth to an unconscioua peraon. SeCTioA 5 .- FIRI FIGHTIIIG MEASI'RES FLASE POII{T r.Er. I1EL None t[/D N/D EKTII{GUS TNG MEDIA Foam, dqf cbenical, carbon dl-oxide or sate! fog. SPECDAL FIRA FIGIIrING PROCEDIIRES: Ifear self-coatained breathing epparaEus (SCBA) arld other protective cLotbi.ng. Hezardou8 deco.poEition productsposaible (6ee Sectlon L0). UNUSIIAIT FIRE AIID ETPLoSfON HAZARDS: HeaE nay build up and rupture clo6ed containers . SECTiON 6 -- ACCIDEIITAT R.ELEIASE UE]ASI'RES STEPS TO AB TAXBN M CASE ITTATERLAIJ IS RELEASED oR SPIITLED! fripe up spill,s to prevents fooEing hazard. Avoial flurhing inEo aewers. dratns, rratenrayE and6oi1. lfear plobect.ive clothing durl.ng clean r:!). Section 7 -- HANDLING At{D STORAGE P&ECAIMOIIS TO BE TAXEN IN HAIIDLING AND STORING: Keep conbainer closed andupright rrhen noE Ln u6e. To prevents freezing ard [roEaible rupture of coaEainer, do not Etole below 40 F. OTIIER PRECAEEONS: Avoid prolonged or repeated contact. vitsh akin orclothing. &!pty contsiners nay cotltain residues and vaporg t treah aa iffull and obgerve a]-l product precautions. Do not reus€ erq)ty contaLaerd. KEEP OUT OF REJACH OF CHIIiDREN. section I -- BposoRl cottrtRot s/pERsoMt pRolEcmoll RESPIRAToRY pROTBCIIOI{ (SPECIFY SYPE): None requifed. VENTIIATION - LOCAL EHAIIST: Acceptable SPBCIAI.: N/A !,IECTIA}IICAT (GENERAI]) : Pref,erable O!I{ER: N/A PROTECTM G'!,O'VES: wear tubber glovee. gYE PROTBCTIOIC: Safety glaeseE (AIISI 2-87.1 or equivalents ) OTEER PROrECTTVE CIJOAHING OR EQuIPMFIr: Covelalls recodneaded. IfORK/I{YGIEMC PRACIICES: tftrere ure calt re6u1t in skin contect, wasb expoded areaa thorougbly befofe eating, atrijlking, emoking, or leaving rrork area. Launder coDlaEi-aated cJ-othing before reuse. SECIiOTT 9 -. PETSICAIJ AND CTIEMICAT PROPERTIES BOTIrIIIG POIMf : N/A SPACIFIC GRjAVITT (rzo - 11 : 1.48 IIAPoR PRESSITRE (t!o Cg): N/A IGLTIIIG POrNt: N/A VAPOR DENS IjrY (AIR - 1): t{/A EIIAPORATrON RiAIE (ErFrr, ACETATE - 1): ![/e APPTARTTICE /ODOR: pinlc / sligrht odor SOI.ItBMna lll ISATR: Inaolub1e SecIioE ]-O .- STABILITT AND REACTTVTTY 2 !4ATERIAL SAFETY DATA SIIEET MSDS 0215 Section I -- PRODUCT AND COMpAt[y IDENrIFfCATfON IIMIS CODES PRODIICT NAl,tE Heal-Eh 1Biostop Fire Rated Putty Pad/Stick Flannabilitv 0 Reactiv-ity O PRODUCT coDEs PPI B 66335, 56490, 5549s CHEMICAI, FAIT'ILY: organj.c/Inolgad.c usE Fireetsopp{ng Sealant MANUFACTT'RER'S NAME EMERGEVCY TELEPHONE NO, The RecEorseal Corpolation Chemtrec 24 Houls 2601 Spenyick Drive (800) {24-9300 Ilouston, rexas 77055 USA DATE OF PREPARA1ION TECINICAIJ SERVICE IEI]EPHOIIE NO. August 7, 2002 (800) 231-3345 secLion 2 -- coMposrTIoN/INFORtIATION OlI l}r@.mlEars t by BT CAS No. INGREDIETCT UNITS 41583-09-9 ftiaziJre TriamiJre phoaDbate ACGIH TIJV N/D ppm osIIA PBL r{/D ppm 12007-56-6 Calcium Borate ACGII{ TIJV lr/D ppm OSHA PEL N/D pPm 68333-79-9 Pol)rphospbolic Acid ACGIH TTJV N/D Ppm OSIIA PEr, N/D ppm 2976L-21-S laodecyldiphenyl E6ter ACGIH TLv N/D ppm osHi{ PEL N/D ppm Section 3 -- I{AZARDS IDENTIFICATIOII SINA,'IRY OF ACIITE HAZARDS May ceuae akin irritation. ROUTE OF EXPOSURE, SIGINS AND SY!{PTOMS IT{EAI,ATIOI{ Not a reEpiratory irritant. EY:E CONTACT Contact nay cams€ eye irritation. SKIN COICTACT contact may cau6€ akitx irritation. INSESTIO}T Possibfe irritatisr to rtrucous mernbranea of the moutsb. throat, alxd stonach. SOMMARY OF OTRONIC HAZARDS None laowa. MEDICIIJ CONDITIOIIS AGGRAI''ATED BY EXPOSIJRE Persong ritb pre-ecisting akin conditions or cheIlical aLlergies nay be noreguaceptible to conlacE effecla of product.. Seclion 4 .- FIRST AID !,IEASIJRES If $!IALED: Not a re6piratory irriranU. ff on SKIN: Wash rfitlx soap and sater. If irritation occutg, aeek ECOIJOGICAI DATA Inoredi-ent Name Food Chain Concentrati.on Potential N/A N/A N/A N/A *ATEnpOWt TOXTCITy BOD AQIRTTC TOXTCITY Section 13 -- DISpOSAI CCINSIDERATIONS nasle Claesifj.calion: Non- regul.at ed 6ol-id wastse Dispo6aL Method: Approved landfiu tfaEte from t'bis product is noE condideled hasardouB a6 defined under the RegorEce colservatioa and Recov€ry Act (RCRA) 40 CFR 251. Dispose of ia accordance with Fed€ral, Sbate, and LocaL re$:.lation regardj.ng pollution. SECIiON 14 -- TRATSSPORTATION ITTFONMATION DOT: ljlon-Regulated OCEAN(IMDG): Noa-Regnrlated AIR (IATA): NoD-Regulated lfI{MIS (CA}lllDA} : Non-Regulated SECIiON 15 -- REGULATORY INFORITIATION REGT'LATORY DATA Ingredient Name Noae SARA 313 N/A TSCA InvenLory A11 component a li6ted CERCIA RQ N/A RCRA Code N/A Seclion 16 -- OTHER IIiIFORMATTON ThiB document is prepared purBuant tso tshe OSIiA llazard corurunicaEion SEandard (29 cFR L9L0.1200). Itre informat.ion hereia i€ given in good faich, but no warranEy, er<pres,sed or inpl.ied iE made. Condult Rectorseal for furtheriafortnatiou: (713) 263 -8001 3 EI(TINGI'S IIIG MDIA Foam, dly chemical, carbo!, dioxlde or vater fog. SPBCIAL FIRE FIGI{IING PROCEDIIRES: tlear aelf -contai-!.ed breatbing apparatus (SCBA) and olher protective clothing. UNUSIIAL. FIRE AI{D E:KPI,OSIO}' HAZARDS: Fire conditsions srill activat.e ploducts causing intunegcence to occur. Section 6 -- ACCIDENTAL RETEASE MEASI,RES STEPS TO aE TAKEN llr CASE MATER.IAL Is REIJEASED OR SPILLED: Pick up debli6 to prevent fooEiag hazard. Sectj,on 7 -- IIANDIJING AND STORAGE PRECAUTIONS 10 BE TaKEN IN HAI,IDLING AttID STORING: Do !'ot store near beat, 6parks, or Open flames . OTIIER PRECAIITIONS: REEP OUt OF REACH OF CHILDREN. SECtsiON 8 -- EKPOSURE CONTROIS/PERSOIIAIJ PROTECTION RESPInATORY PROTECTION (SPECIFY ITPB): None required. VEIiIIILATION - LOCAIT EKHAUST: N/A SPECI{L: l{/A !{ECII!|NICA! (GEMRAI") : IiI/A OTHBR: N/A PROTECTIVE GLOVES: W€ar cut lesiEtant gloves. EyE PROTECTIoN: Safety glasses (AlrSI 2-87.1 or eqrdvalents) OTHER PROTBCTM SLOTIIING OR EQIIfPI4ENr: Covera]"].s reconmended. noRR/IfycIBNlc PRACTICES: trtrere uee c;ur result in ekin contact., wash exposed areaa tboroughly before eating. drinking, smoking, or leawilg work area. Launder contaoinaEed clotbinq befote reuae. SECI,iON 9 -- PKYSTCAI AND CHEMTCAIJ PROPERTIES BOIT,II$G POINT: N/A SPACIFIC GRAVITY (H20 = 1): 1.53 POR PRESSURE (m H9): N/A I,IELTING POIlilI: N/A \TAPOR DEIIS ITY (AIR = 1): N/A EVA.PORATION RATE (81'EfL ACETATE = l.): N/A APPEARAiTCE /ODOR: Black / Mild Odor SOLUBILIIY IN IIATER: Insoluble SecTion 1.0 -- STABITJITY AND REACTIVIT]. STABILITY: Stable COI{DITIONS TO AVOID: None INCOMPATTBILITr (MATERIAIS TO AVOID): None known. IIAZARDOITS DBCO|,IPOSITION PRODUCTS: CO, COz and frag,mented hydrocarbons. IIAZARDOUS POIY!.{ERIZATION: I{iI]. not ocsur. SecEioa 11 -- TOXICOLOGY INFOR!.{ATION CIIROIIIC IIIA].TH HAZARDS No ing?edien! in this product i6 arr IARC, li|:fP or osHA tiaEed carcinogen- TOXICOLOGY DATA Ingredieat Name Noae Sectio!. 12 -- Ecological Inforroation 2 I|ATERIAI. SAFETY DATA SI{EET MSDS 0591 Seclion 1 -- PRODIICT AIID COMPENY IDENTIFICATIOT{ Htfis coDEs PRODUCt NAMB l{ealth 1 Bioatop FiresEop cask€t Flamnablltfy 0 Reactivity 0 PRODUCT CODES PPI B 66260, 6626L, 6627L. 66273, 66273, 66277 CIISiIICA', FAMIIY: OrganLc/Itrorganic I'SE Firestoppiag Material- }'ANUFAEN'RER'S NA|,TE EMERGENCT 1TLBPHOITB NO. Tbe RectorseaL Corporation dremErec 24 Hour6 2601 gpenvick Drive (800) 424-9300 Houston, Texas 77055 ItsA DA!E OF PREPAR,ATION TECHMTCAI, SERVICE TEIJEPIIOIIE NO. itanuary 7, 2003 (800) 231-3345 section 2 -- CO|,IPOSIfION/I}rPORIBTIoN ON MGREDIENTS t by nT CAS l[o. IISGREDIBNT uNITlt lilone as defineal by OSIIA llazatd CorErunicatioEr Steldard 29 CFR 1910,1200. SECIiON 3 -- }IAZARDS IDEMTTFICATION STJ!'MARY OF ACTIIE IIAZARDS May cause Ekin irf,itat.ion. ROTITE OF EXPOSI'RB. SIGI{S AND SYMSIICMS INTTAIJ\TION NoE a le6ltiratory iFitant -gYE CONTACA Cootact nay cauae eye iEilation. sKrN colqrAcl Contact may cause Ekin irritatidr. IISGBSTI6T PogEj.ble irritsation to GucouE menbraneE of the moulh, tlrroat, and stomach. ST'IA{ARY OF CHRONIC HAZARDS None lgror$1. MMICAL COIIDITIONS AGGRA\TATED BY EXPOSIJRE Peraon6 l'ith pre-exigting akin conditiorrs or dtenj.cal allergdes nay b€ ft)re susceplible to contact effectE of tshe cured ela6torn6r. SECIiON 4 .- FTRST AID ME;ASURES If INEAI,ED: l$ot a reapiratory irlitart. It on SKIN: tfa6h uitb soap arnd reter. If initation occurs, aeek medical ettenEion. If ia EYES: Imediately flush sitb large amounts of wate!. I! irritsation occurs, aeek nedical attention. If Sl{ALLollD: If swal:.owed, call a pbysician irutrediaEely. Oaly induce vooitirg at tbe itar.ructioa of a physicial. t{ever give anythiDg by $outlr to erl rmconEcious per8oa. SECt1ON 5 -- FIRE FIGETIIIG MEA.ST'RES FI,ASH POINT None I.EI, I]TL N/D }I/D EC€LOGICAI DATA lngrredi.ent Nane None Food Cbai!. concentrati.on Potential N/A rIAAERFO'IL IOXICITT r/ABOD N/A AQI'ATIC TOXICI1T tI/A section 13 -- DrsPosAL coNsIDERATroNs Wa6te classificat.ion: [on-regrulated soli.d rraEte DisposaL Metl:od: Approved latrdftU lfaate from this product is not coDEidered barardoua as defined lmder tslae Reaoulce Conaerlration and Recovery Act (RCRA) 40 CFR 251,. DisEroge of inaccordance witb FeCleral, State, and Local regmlation regardirg pouut ion. section 14 -- TRANSPoRTArIoN INFoRUA?ror[ DOTI Non-Regulated OCE:AN{IMDG): No{r-Regulaled AIR (IAIA) : N@-Regutated WIIMIS (CAI{ADA): Non-RegmlaEed SECI,iON 15 -. RECII'LATC}RY IIIFORIiIATIOT{ REGT'IJATORY DATA Ingrredieat Name Noae SARA 313 N/A TSCA IDveaEory A1l coq)onenEs ILstsed CERCI,A RQ N/A RCRA Code N/A sectsion 15 -- OII{BR INFoRMATTON This docun€lrt is prepared pursua!ts to tsbe OSm ltazard Cot[mmication Standard (29 CFR 1,910.1200). lbe information herein i6 given in good faith,but no varranty, expreased o! iq)lied i-g made. conEult RecEorseal for furtherinformatioq: (713) 2G3 -8001 3 E$TICUSING MEDIA Foam, dry drerni,cal, carbon dioi(id6 or naler fog. sPBcrAL FrRE FrGETrrlc pRocEDnREs: Irear seff-contained breatbi.ag apparacus (SCBA) and oEher protective clothing. ttNusrtAl FrRE A!{D E:KProsro[ HAZARDS: File conditiona wirl act.ivate produc! causiDg intu[esce4ce !o ocsur. SECI,iO! 6 -- ACCIDEMEAIJ RETEASE MEASI'RES srEPs ro BE TAKEN rl{ cAsE MATERTATT rs RETJEiASED oR sprLrrED: pick up debrig toprevent fooLing ha.zard. Seclion ? -- I{A}IDLII\IG AND STORAGE PRECAUTIONS !O BB TIKEN It{ IIA}IDLINC Al[D STORING I Do not store near heac.spark6, or olren flamer. O${ER PRECAIJTTONS: KEEP OIII OF REACE OF CHIITDRBN. section I -- ExposIJRE coNlRoLs/pERsotBIr pRoTECtIOlr RASPIRATORY PROTBCTION (SPECIFY TTPB): None requiled. VEIITILATIoN - LOCAL EKIIAUST: N/A SPECIALT N/A MECIImnCAI (cEl{BRAr,) : N/A OTHER: N/A PROTECTM GLOVES: wear cuts re6i6Eant gloves - ElrE PROTECTION! Safety glasseE (ANSI 2-92.1 or equivalenE) OTHER PRc)|fEctM CIOTI{II{IG OR EeOfpMEMt: Coveralf6 reconmended. IKIRK/HxGrEIcrc PRACITCES: nhere uae caa resul,t in skin contact, $aEh expoaedaleas thoroughly before eating. drilki_og, amoking. or leav-ing rctk area. Launder contaminated clotbing before reuse - Sectlon 9 -- PFTSICAI AND e|EMICAL PROPIRTIES BoILMG POrNI: N/A SPBCIFIC GRAVITY (H20 - 1): 1..63 VAPOR PRESST RE (mn IIg): N/A MELTING POINT: N/A \TAPOR DENSITY (AIR - L): N/A EVAPoRATION RAlllE (ETIIYL ACEIATE = 1): N/A A"PPEARiANCE/ODOR: 81ack / Mild Odor SOLITBILITY IN TIATER: In6oluble sectior 10 -- sTABIr,rly AltD REAcrrvur SIABTLIIY: Stable CO!@ITIONS To AVoID: None INCOI'PATIBIIII'Y (MATERfALS aO AVOID): None lcrowrr. IIAZIRDOUS DECOMPOSI?ION PRODUCTS: CO, CO2 aad flagroented trydrocarbons. IIIIZARDOIIS POLYIT{ERIZATION: rfiLl aot occu!. SecEi.on 11 - - TCTXICOLOGY INFOR!,RTION C}IROTTC HE,AITII HAZARDS tilo ingredient j.n tbis product is en IARC. Ii|lfp or OSHA lisbed cafcinoge!.. TO:'ICOIPSY DATA lngredient Nane None Sect,ion L2 -- Ecological InfonEtioa 2 I.BTERIAIJ SAFETY DATA SIIEET MSDS 0480 Secti.on 1 -- PRODUCT AIID COMPAN:r fDEMIIFICATION TIT4IS CODES PRODttcT IBME l{ea1tsh L Eio Fireahield tectra-stop Flamr€bility o Reactiv:ity 0 PRODUeT CODES PPI B 56495. 66497 C}IE$IICAI, FAFIII,Y: Or:ganic/Inorga!'ic ttsE Electrical Box Inaert MANI'FACN'RER''S NAI.IE EMERGEIICY TEIJEPHONE NO. The Rectorseal. Corporation chemt.rec 24 Hour6 2601 Spelxuick Drive (800) 424-9300 Hougton, Texaa 77055 USA DAIE OF PREPARATION TECI{NTCAI SERVICE TSLBPHON! NO.,tuly 24, 2002 (800) 231-3345 SECtiON 2 -- COMPOSI1IOTT/INFOR!'AIION ON I}IGREDIEIITS t by wT cAs No- IIIGREDIENT ITNITS None as defined by OSIIA Hazard Co runicaEion Standard 29 CFR 1910.1200. Section 3 -- nZARDS fDENIIFICATION SUMIIARY OF ACTITE IIAZARDS May camse skin irritalion. ROtxrE OA STPOSITRE, Srctrs AID SYMPTOMS INIIAIJATION NoE a reapiratory irri-tant. TYE q)NTACT Contact lray cause eye irritaEion. SKTN CONTACT Contact nay cauae Ekin irfitation. IlvGiBSTIOEI Poscible irrj.tation to mrcouB membranes of the moutb, throat, and ator0ach. Su![ilIRY OF CHRONIC IIIZ.ARDS None lsrowa. MEDICAI, CONDITIOIS AGGRA\IATED BY BXPOSURE Peraona with pre-exi6tj.ng Ekin cotrditsiona or chemicaI aLlergiea n.ay be more susceptibl-e to conEact effects of tbe cured elastoner. Sect ion 4 - - FIRST AID ITIEASI'RES If fiE(LED: Not a respj-ratory irriEant.. If oq SKII{: nash yit}r aoap and water. If irritatsion occurB, aeek medical atteation. If i-n EYES: Imediatsely fluah yith 1a!ge ar0oulEg of rate!. If irriEation occurs, seek medical attantion.If SwAI,rrolf@: If awalloved, caLl a physiciar iomediatel-y. Only induce rr@ititrg at tbe instructioa of a phyaiciaa. Never give anythinE by nouth to an unconacioug per6on. SecLion 5 -- FIRE FIGI{:rING ME.ASI,RES FI,ASH PONflT None IJEL I'EI }T/D N/D PRODUCT DATA SHEET Biostop- Fire Rated Putty and Putty Pads Classif ied Through-Penetration FireStop System Number CXJ1202, CAJ3105, CAJ3106, CAJ0046 and CAJ1207.'"6-g Dec€mber 2002ffi Hffi 1. Product Description Biostop* Putty is a moldable non-curing one component fire-rated material lor through- penetration firestop systems. Biostop* Pufty will intumesce when heated, forming an insu- lating char. In the event of a fire, Blostop* Putty will pre- vent the spread of flames, smoke, gas and waterthrough penetration openings. Biostopw Putty is applied by hand. Mixing is never required and no special skills are nec- essary for installation. Biostop* Putty is tttted for up to 3hours in accordance with the ASTM E 814. UL 1479 and ULC/CAN+SI 1 5-M test stan- dards, Use Biostop" Fire Rated Putty for various penetrations: Small Openings, EMT Pipe, Steel, Conduit, and Cabling, (Ielephone, Power, Commu- nications) and metal or non- metallic Electrical Boxes Use Biostop* Fire Rated Putty Pads for: Metal or non-metallic Outlet Boxes, Electrical Gabinets, and Mechanical Cabinets Biostopru Putty Features* Possesses intumescent propertles; expands when exposed to fire. " No Volatile Solvents, which makes it particularly useful when installing in confined spac€s or occupied areas. * Does not have Asbestbs Fill- ers. * A single component putty system; no mixing neces- sary and no required addi- tives. " DOT Classification is Not Regulated. * Applied by hand. * Easy to install. " Adheres to all common building common surfaces. * Water resistant 2. Material Prcpertles Asbestos Fillers None Application By hand Color Red Cure Time None SpecificGravity 1.,189/cc Activation of Intumescence: Expansion Begins220'F Putty pads STC Rating 49 Tested in accordance with ASTttl E 90-97 3. Appllcations Use Biostop" Fire Hated Putty to seal around cable, electrical conduit and metal pipe to pre- vent passage of smoke, flame and toxic gases. Use Biostop* Fire Rated Putty Pads to pro- tect metal electrical cabinets, outlet boxes and mechanical cabinets. 4.Installation lnstructions PUTTY: Penetrating items should be firmly anchored. Clean open- ing of dust, dirt and oil. Refer to RectorSeal@ application guide or current UL directory for selection of proper system design detailing depths of putty and backing material. PUTW PADS: Remove liner from one side of pad (Step 1). Align with the side of the box partially over- Putty and Putty Pads o Fire RatedBlostop*m_ lapping the stud and adhere. Work pad to the opposite side of the box and over the edges (Step 2). lf wall membrane is in place, pack putty into gaps between box and gypsum board slightly overlapping in- nerwallboard surface. lf mem- brane is to be installed after pad installation, overlap front edge of box so that putty will be compressed around edges of box as wallboard is in- sralled. cut slits in pad to fit around conduit or cables (Step 3). Press pad to surface of top, bottom, and sides of box (Step 4). Trim excess at corners and apply to conduit fittings connected to the box. Remove exposed liner. Op- tionally, putty may be packed into inside of conduit fittings to prevent passage of smoke. Only one putty pad thickness (1/8") is needed for a 1 or 2 hour rating. 5. Testing Data Biostop" Fire Rated Putty is classified by Underwriters Laboratories, Inc. as a fill, void or cavity material. Biostop* Fire Flated Putty Pads are classified as a wall opening protective material. For spe- cific test criteria see UL Fire Resistance Directory or call RECTORSEAL. Biostop* Fire Rated Putty was tested at a minium 0.01 inch of water, positive pressure in ac- cordancewith UL 1479, ASTM E 814 and CAN4-S115-M. 6. Storage & Handling Biostop* Fire Rated Putty is not to be stored in areas where the temperatures ex- ceed 120'F or drop below 0'F. Best if protectedfrom freezing. lf freezing occurs, thaw com- pletely before using, Keep products dry and stored under protective cover in their origi- nal conlainea. Products have a minimum shelf life of 2 years subject to re-inspection there- after. A stock rotation prognm is recommended. 7. Availability Moldable Fire Rated Putty available in 1 112 inches diam- eter by 10 inches long (18 cu- bic inches) Moldable putty pads are 6 inches by 7 inches by 1/8 inch thick and 7 inches by 7 inches by 1/8 inch. 8. Llmltations Do not expose to water. 9. CAUTIONS FOR CHEMICAL EMER. GENCY, SPILL, LEAK FIRE, EXPOSURE OR ACCIDENT, CALLCHEMTREC. DAY OR N|GHT 1-80G 42+9300. For additional inirrmation, re- fer to Material Safety Data Sheet For additional technical servlce, call: 1€0G231-33,'lS Fax: 1-8O&4i52-2824 RECTOBSEAL 2601 Sp€nwick Ddvs Houston, TExas 2055 wtwY.bitir€€hi€ld.com 10. LIMTTEDWARRANTY Recf€d mabGfhe Llml€atE9Fgg $htranyhdwh€ntha lrltnrliorEbrsbragaand hudlhgotoorprductsar€blloird t€rErrarnou WAFRANTY IS WRESSLY IN UEU OFANYOIHEF O@RESS OB IIFUEOWAFMNTIES IiELUOI'IG A'{YIMPI.IEDWARMNTY CIF MEFCMN'AEIUTY Ofi FITNESS R)RAfiFIIdJLAE PURPCISe AND OF ANY OfEn OBUGAnI Oll THE mHT OF RECtOFISEAL.Th€ 6ole Bmdybr bEach ol the Urnlted EgtEs! tAbnuty slsll b6rn6 rE und.f th€ purrlrss6 Blce Al dh€r lablky b n€gal€d ard dbabino4 a'|d R€cbrs€al 6rEtl rd bs |Llrl€ b l.ttFftt or cois€qJsriial &|||sgEs, Sugg6dorc {d aEconnEraalbrb coEftg tlt6 us€ d olr FdtEE aF bEFd oi ou. past oeargEs and bbordorllndhos. Hf'rer, als urs tq\ro m cottrEt aFpllcatlon, E onv ascldrE Eapor€b ity tor tfE unilbfinlv of our p@dlEts withh mandacfurirE tol€rsrt6n Zlla PRODUCT DATA SHEET Bio FireshiEIdTM LECTRA-STOPTM Classified under Wall Opening Protective Material as found in UL's Fire Resistance Directory ."ffif*- \z-- o ffi_9H June 2002 (ffilleo6cr htuutiotul fr€WCoffil 1. Product Description Bio Fireshield* LECTRA- STOP* is a one component fire rated pad for use in electri- cal boxes. lt is inserted on the inside back wall of an electrical box, and is a highly intumes- cent firestop material. When exposed to fire, Bio Fi reshield* LECTRA-STOP" willexpand forming a charthat will seal off the opening and prevent the spread of flames and limit the temperature rise on the unexposed surfaces. Bio Fireshield* LEGTRA- STOP* is applied by hand, and must comply with NEG 370-16 or other applicable codes. BIOSTOPTM Electrical Box lnsert Features ' Easy to lnstall * Cost Etfective . Highly Intumescent * Adheres to Back of Electrical Box * Non-Conductive ' Dielectric Breakdown Voltage 22Ylmil (ASTM D 14e) 2. Material Properties Asbestos Fillers NoneSolvents None Hazardouslngredients None Sizes (Approx.) Single box 1 13/16"x213/16"x1l4" 47mmx71 mmx6mm Double box 3 1 1/16" x3 314' x 114" 94mmx95mmxGmm Color ASTM E 84, UL 723 TUnnel Test Flame Spread Smoke Index STC Rating 55 3. Applications Use Bio Fireshield* LECTRA- STOP* on inside back panelof electrical boxes to maintain the integrity of fire rated wall as- semblies restricting the pas- sage of flames and limiting the temperature rise on the unex- posed surfaces. When Bio Fireshield* LECTRA-STOP* is used as directed, the horizontal separa- tion between outlet boxes on opposite sides of the wall may be less than 24 inches pro- vided that the boxes are not installed back-to-back. 4.Installation Instructions Bio Fireshield" LECTRA- STOP* is easy to install by ll- censed Electricians. Make sure rear surface is clean, dry and not contaminated. Remove protective paperfrom tape and stick pad to inside back wall of electrical box*. Center pad from top and bottom ot box. lnstall switch, or outlet. Use the small pad for a single box (2" x 4"), and one large pad for maxi- mum 4" x 4" box. Make sure installation complles with NEC 37tr16 or other appli- cable codes. 'lf necessary slit the pad from one edge to allow access to the ground screw Do not remove material from the pad. 5. Testing Data Bio Fireshield* LECTRA- STOP* is classified by Under- writers Laboratories, Inc. under Wall Opening Protective Mate- rial as found in the Fire Resis- tance Directory. For specific test criteria see UL Fire Resis- tance Directory or call RECTORSEAL. Bio Fireshield* LECTRA- STOP" was tested at positive pressure for a minimum .01 inches of water. The basic stran- dard used to investigate prod- 5 5 2.4 LECTRA.STOPTN o FIRESHIELDTMBIO ucts is UL 263/ASTM E-1 19, "Fire Tests of Building Con- struction and Materials". 6. Storage & Handling Bio Fireshield* LECTRA- STOP" should be stored be- tween 35' F and 120' F. Keep products stored under protective cover, in their origi- nal containers. A stock rota- tion program is recom- mended. 7. Availability Bio Fireshield* LECTRA- STOP" is available as pads measuring, approximately 1 13/16" x213116" x114" (47 mrn x 71 mm x 6 mm) and 3U4'x3314'x 1/4' (95 mm x 95 mm x6 mm). 8. Limitations To be used only in the tested configurations or as recom- mended by RectorSeal. 9. CAUTIONS FOR GHEMICAL EMER. GENCY, SPILL, LEAK, F|RE, EXPOSURE OR AC- CIDENI CALLCHEMTREC - DAY OR NIGHT 1.800. 424-9300. PRECAUTONS: tlo nottak€ intornally. tvlay be harmtul it sarallo^€d. tllay cause ey€ eld skin initatlon It prolonggd or r€peated contract occurs. Wash atter handhg. FIRST AID: Foranyov€rdposure, gstimfl€date medical atterdon aft€rfirstald is gi\i€n. Ey6-Flush 15 minubs vrith dean rEter. Skln-Wbsh witt Soap and water. hg€stlononly It conscioris, giw laE€ anlounts of {laler and call ptrysbhn. F[fE AND SPR-LS: t ce wabrtog, COr, tuam, or dry ch6mtcals. wip€ up spllls to prer€nt boting hazad. CLan up with sclap€ls ard watgf. STORAGE AND HANDLING: Store atvay trom h€st sources. KEEP gUT OF REACH OF CHILDREN. Foradltbnd holrn ddr r*rb lbt rhlsahytbtr Std. For additional technical servlce, call: 1-80G231-33/$5 Fa* 1-80f},452-2824 BEGTORSEAL 2601 Spenwick Drive Houslon, Tsxas 77055 wflr.bifI€shbH.com Not to be used on wlth internalclamps on plastic boxes. Retain copy of the Product Data Sheet for review by the 10. LIMITED WARRANTY Recbas€rl r€bghsUrifadEgt€$ $ratdnyrhdwtra[ths btLdo,Elorrio.agsandhardllnga*oorpld.E€E sflloN9dwe{Eflmou WARRAIITY IS EGRESSLY NUAI OFAT.IYOIHER EXPNESSOH MruED WARRT{NES IiICLUOIiGAf{Y IMPLEDU'ABRAfiTY OFMEFCHAI{TASUTY OR FTTNESSFt}RAFAHNCULAF PURPOSE AND OF ANY Otl{EE OtUOAT|ON ON THE FhRT OF BESTORSEAL. Thg sole EnFdylor bBach dfE Llntt€d 6e|lss UJlnEr{y !h.I bo th€ r€turd otitE putrh.$ Frbe. Alourlablity b negd€d ald &chimed, and Fdb.S€d 6l€l not !a tht . tgr hEttul o. cdE€erdat (b|'|.g€i su9g€suon9dI'drecorfi6ndat|on3coicrh!ih€Eeo|.U'prod{rFar€bar6donotrr!€!ltgQ!rterEoandtaboraorfhdhg6.Hf5,6r|8w9hgwFqoito|aI'totfFd qilcatb.l, !re oalv a$urr rE$o,Ebiltyloa tlE rlltonn.ly ot our prldl6 wlttn fiarukctrirE tderam6. L23. PRODUCT DATA SHEET BIOSTOPTM Firestop Gasket Classified under Wall Opening Protective Material as frund in UL's Fire Resistance Directory o @rt?nc|vtD December 2002 (bEli{cnD€r hftnrdiod ItoESbpCrud'ffi- BIOSTOPTM Firestop Gasket is a single component fire rated gas- ket for use with electrical boxes when addressing the "24 inch rule". lt is mounted on the inside of the cover plate and installed at the same time as the cover plate, covering the opening and provid- ing the necessarylire protection. When exposed to heat, BIOSTOPTM Firestop Gasket's highly intumescent nature causes it to expand forming a char that will seal olf the opening and prevent the spread of flames and limit the temperature rise on the unexposed surfaces. BIOSTOPTM Firestop Gasket is applied by hand, does not take up volume in the electrical box and is a labor saving replace- ment for putty pads in normal applications, Patent Pending. BIOSTOPTM Firestop Gasket Features . Easyto Install . Cost Eftective * Great for sale retrofit applica- tions * Reduces sound transmission Asbestos Fillers None Solvents None Hazardouslngredients None Sizes : 66277 Single svrritch 66275 Double switch 66273 Singlereceptacle 66271 Doublereceptacle Packed 50 per case Golor Black ASTM E 84, UL 723 TUnnel Tesl Flame Spread Smoke lndex STC Rating 54 Tested in accordance with ASTM E 90-99 also be used as a solution lor stan- dard electrical boxes when the 100 square inch rule is violated. BIOSTOPTM Firestop Gasket is UL tested and can be used with both metal and plastic cover plates. Tested conditions for one and two hours. 4.Installation lnstructions BIOSTOPTM Firestop Gasket is easy to install. 1) Place aluminum foil side of BIOSTOPil Firestop Gasket against inside ol electrical face plate. 2) Do not remove any material, film or foil from BIOSTOPTM Firestop Gasket. 3) ln- stall tace plate with BIOSTOPTM Firestop Gasket over $i/itch or re- ceptacle and secure hce plate with screws, 5 5 a.hdrFl'r.Fof r.d.od!_ t\\ *i- *i- lnstalh{on ol Slngle ElocHcal Sudtrch I 1. Product Description 2. Material Properties ffi H @ H 3. Applications ffi *r*ffi,-\ I I BIOSTOPTM Firestop Gasket is used when electrical boxes are installed in rated walls facing op- posite directions and horizontally separated by less than 24". BIOSTOPTM Firestop Gasket can Installdlion ot Singlo Re6ptrdE 2.N BIOSTOPTII FIRESTOP GASKET 5. Testing Data BIOSTOPYM Firestop Gasket is classified by Underwriters Laboratories, Inc. under Wall Opening Prolective Material as found in the Fire Resistance Directory. For specific test cri- teria see UL Fire Resistance Directory or call RECTORSEAL. BIOSTOPTM Firestop Gasket was tested to UL 263/ ASTM E- 119 standard. "Fire Tests of Building Construction and Mat+ rials". lt meetsthe requirements of all model building codes. 6. Storage & Handling BIOSTOPTM Firestop Gasket should be stored in a dry envi- ronment. A stock rotiation pro- gram is recommended. 9. CAUTIONS FOR CHEMICAL EMER. GENGI SPILL, LEAK, FIRE, EXPOSURE OR ACCIDENT, CALL CHEMTREC. DAY OR NIGHT 1-8(XF42't-9300. PREGAIITFNS: Do not bko internally. tr/by b€ hatfiful it sr'€llonEd. luay cau6e €ys ard skin irihtion if prolonged or repeated mnied occurs- Wa.sh after handling. FIRSTAI& Fol any ovErdeosure, gs1 imm€dato modcal atontion afterfrst ald ls gi\€n. Eyee'Flush t5 mlnubs with closn watsr. Sldn-Wash wifi soap and water. hg.don€nlyf consdous, g[ve large arnounts of ttraior and call plrysbhn. FIFE ANDSPI-IS: Us€ uabr bg, Cq, toam, or dry c$emicals. Wlp€ up spills to prqrent bdting hazad. Clean up with scrap€rs and water. STORAGE AND IIANDLING: Stor6 away lrom heat sourc6s. KEEP OUT OF REACH OF CHIU'REN. Forsdoid mfirddt derto l'|ddlsaLv &Eglet For addltlonal technical servic€, call: 1-800-231€3/15 Fa* 1-|cfll0-452-2824 RECTORSEAL 2601 Spenwick Driv€ Hou$on, Texas 77055 www.BroFlBESHrs-D.coM 10. LIMITEDWARRANW Rsrselmdlh.thndEg€.sltlttlE/ihdwlptlhettmdo.rlor!B.gE.rdh.rdrEotdrprodd!s€b{oEdswr?r!ourptrd.@!ob.tcsfGmddbcrETHtgUMfTEDE@nEss WARFAI{W ISD(Pf,EssiLY IN UEIJ OFANYOI}€R O@RESS CIR IMPUED WAFRANMES, NCLUOINGAI.TY TMPLIED WAFRANTY OE UENCXTTTNSTUTV ON FTTi€SS FOR AFAqnCULAR PURPoSE,AND OF AtlYOIHEFI oBuOAlIOll { THE PAFT OF REClORSEAL Th€ $l€ EnEdyt heh otth. unt dEreEe tlttarE ty stt iN b6 th€ d!,lrd of theArha.€ pbe. AI ouErI$ tyb D€tbd arld &chlfir€d, and H€a,b6€sl shetl not b lbli€tba lrEt anbl or corEqr|lbl darta€Ea, Sugge$n6 arlEcdtnF ddbB crt€rtE lhe u8a d oLa FtdB arE basd on o!r pagl qrbrE ,nd hbodorylldngr. HoFv€r, G F haE rbco.tol as to th€ mf srt c.r,tdlbt3 of appliadlon, w! o{ y ss6unE rEspoBblllv1br th6 unfornny ol otr prld.EG wihln nEmlaairtrE totdanc63 O 7. Availability BIOSTOPTM Firestop Gasket is available as single switch, double switch, single receptacle and double receptacle. 8. Limitations To be used only in the tested conf igurations or as recom- mended by RectorSeal. Bio Flreshield Firestop Gaskstr for use with max ,l-1 li 16 by 4-11116 in" flush dwice UL Listed Metallic Outlet Boxes insailed witt st€el or plastic cover plates in 2 h fire rafed gypsum board wall ass€mblies framd with min 3-l/2 tn- deep steel studs and constucted of the materials srd irr ths rnanner specified in the individual U400 Soies Wall md Partition Designs in the Fire Resishce Directory- Nom 2 by 4 in. or 4 by 4 in. gaskeb to be installed on the inside of single gang or double gmg cwer plates, respectively, prior to attaclrment to device. Installation to comply with Article 370 of the National Electrical Code NFPA 70). Whenprotectivematerial isused within cover plates on outlet boxes on each sides ofwall as directed, the horizontal sepuation betweea outlet boxes on opposite sides of the urall may be less than 24 in" provided the boxes are not installed back-to$ach Bio Flreohield Firestop Gaclets for use with max 4-llll6by 4-11116 in" flush device UL Listed Metallic Outlet Boxes insta[ed with st€el or plastic cover plates in I h fire rated g;psrm boad waII asse,mblies framed with min 3-l/2 in- de€p steel shrds and coustructed of the matetials {nd in f[s mqnner specifed in the individual U,,100 Series Wall and Partition Designs in the Fire Resistance Directory. Min 4 in thick fiberglass ('nin O5 pcf) or mineral wool (min a.0 pcf) bat insulation is to be inddled within the wall cavity. Nom 2 by 4 in. or 4 by 4 in. gaskets to be installed on the inside of single gang u double gang covcr plateg respectively, gior to attacbment to dwice. Installation to comply with Article 370 of the National Electrical Code, (NFPA 70). When potective naterial is used within cover plates on outlet boxes on each sides of wall as directe{ thc horizontal separation betvreen ortlet boxes on opposite sides of the vrall may be less than 24 in govided the boxes are not installed back-to-back Bto trlreshield trlrestop Garketr fc use with max 4-l l/16 by 4-l l/t6 in. flush device UL Listed Metallic Outlet Boxes insalled with Decca style steel m plastic cover plates in I h fire rated gpsum board wall assemblies framed with min 3-12 in. deep steel studs and coaslructed of the materials and in the mrnner sppcified in the individual U4fi) or V400 Series WalI and Partition Desigrs in lhe Fire Resisfiance Directory. Min 4 in thick fberglass (nin 0.5 pcf; or mineral wool (min d.Q psf) lsft insulation is to be instatld withh the wall cavity. Nom 4 by 4 in. gaskas to be installed on the inside of dqrble gang cover platcs prior to attachment to device. Installation to comply with Article 370 of the National Electrical Code, (NFPA 70). When protective material is used wi&in cwer plates on ortrlet boxes oo each sides ofwa[ as directe4 tbe horizontal separation behveen outlet boxes on opposite sides ofthe wall may be less rhan 24 in ptovided the boxes arc not installed back-toback on both sides ofwall as directed, the horizontal separatiotr between outlet boxes on opposite sides of the wall may be less fien 24 in- pmvided that the boxes are not installed back-to-back Biootop Lcch. Stop lDserts for rrse witt max 4 by 4 by 2-ll8 in deep flush dwice UL Listed Metallic Ortlet Boxes without internal clqs in I hr fire ratd gypsum vallboard wall asse,mbties framed with min 3-l/2 in.deep s&eel studs od constucted of the materials and in the menner specified in the individual U400 Series Wall and Partition Desi.gnc in the Fire Resistance Directory. One !X mm wide by 95 rm high insert adhered to the interior back rra[ ofthe outlet box ia accordance with the installation instuctions sr4plied witt the product" lnstallatim to conply with Article 370-16 of the National Electrical Code, INFPA 70). Outletboxes installed withplastic cover plates. When pmtective rrat€rial is used within outlet boxes on botr sidcs ofwall as directe4 the horizontal separation between outlet boxes on opposite sides of the wall may !s lsss rlrrn l{ in. provided that the boxes are not installed back-to-back UL does not firniS a detail drawing for these listings o ioctop Fire Rated Putty Pads foruse withmax 4 by 4 in. flush wice UL Listed Metallic Outlet Boxes installed with stcel cover lates in I and 2 h fire rated gypsum wallboard wall assembtes @Glr framed with min 3-l/2 n deep wood or steel studs and the wall may be less than 24 in. provided that the boxes are not back-to-back fire Rded Putty Padc for use with max 4 hy 4 in. flush Listed Metallic Ordlet Boxes lnstalled with steel or cover plates in I h fte rated gpsuo wallboard wall framedwithmin 3-ll2b,. deep steel studs and of the materials and in the manner specified in the individual U400 Series Wall aod Partition Designs in the Fire Resistance Directory. 1*s 1s,'ers ef '''in 1/8 in thick moldable putty pads arc to be installed to completely cover the exterior surfaces ofthe outlet box includiog the side of the outla box against the stud. Nom U2 in plaster rings installed ove! outlet boxes. After installation of glpsum boad nom l/4 in. thictness ofRectorseal Biostop 50Or Sealan! bearing the UL Classificatiod Mrking for Fi[ Void or Cavity Materials, applied betwee,n gpsum board and the plaster ring. When moldable putty pad outlet ,i constuded of the materials and in the manner specified in lhe ; individual U300 or U400 Series Wall and Partition Designs in the ,$ fire nesistance Directory. Min l/8 in. thick moldable putty pads f; ae to be irutaled to completely cover the exterior zurfaces of *[ the outlet box (except for the side ofthe outlet box against the ! stud) and conpletely seal agaiust the stud withh the stud € .""ity. Wben moldable putty pad outlet box protective material is t used on boxee on both sides ofwall as directed, the horizootal I separation between outlet boxes on opposite sides ofthe wall may E be less than 24 in. uovided that the boxes are not insta[edt t".k-to-u""k.goa f, niostop Fire Rrted Putty Pads for use with max 2-3/16W 3-314 fby2-llR2 io deep UL Listed Nonmetallic Outlet Boxes f manufactured by Pass & Seymour lnc. under the.tade name Slater, imade from polyvinyl chloride and bearing a 2 h rating rmderthe g fi "Ortlet Boxes and Fittings Classified for Fire Resishce" f; f; category in the Fire Resistmce Directory. Putty pads and boxes t g for use in 2 h firc rated Spzum board wall assemblies framed E E with -i" 3-ll2 in. deep wood or steel studs and constnrcted of { ! Ae mataials and in the manner specified in rhe individual U3fi) ! | or Ua00 Series WaU and Partition Designs in the Fire Resishnce f E Oircctory. Ortlet box secrred to studs by means ofmormting tab I $ srpp[ed with the outlet bor Min l/8 in. thick moldable putty 5 I ptdr are to be installed to completely cover the exterior f ! surfaces of the outlet box including the side of the outlabox N t apinst the stud. Ortlet boxes installed with steel or plastic S fi cover plates. When moldable putty pad outlet box protective $ f; material is used on boxes on both sides of vrall as directed, the $ f,hotzontal separation between outlet boxes on opposite sides of $ !1 fle E€ t to$Itt:s :g $ constructd of the matedals and in the manner specified in the i individual U,100 Series Wall and Partition Designs ia fte pip f; nesistance Oireclory, One 47 rnm wide by 71 rnm high insert adhered E to the interior back wall ofthe outlet box in accordance with { tt" io.al"tioo inshuctions srpplied with the product. I Installation to cooply with Article 370-16 ofthe National fi Hectical code, (NFPA 70). Outlet boxes instaled with steel ! cover plates. When protective material is used within outlet $ boxes on bott sides ofwal as direct€{ the horizontal g separation betrn'eer ortrlet boxes ou opposite sides ofthe uall may I be less than 24 in provided that the boxes are not instdled .f; Uact-touact.tE f,niortop fecfa Stop Inrertc for use with max 4 by a by 2-l/8 in € deep flush dwice UL Lisrcd Metallic Outlet Boxes qrithout liot",:rd rfr-ps in 2 hr fte rated glpsum wallboard wall S assemblies framd with mh 3-ll2 n. deep steel studs and fi coostnrcted of the materials and in the manner specified in the ! hdividual U400 Series Wall and Patition Designs in the Fire t Resistance Dkectory. One 9$ mm wide by 95 rnrn high insert adhered S to fte interior back wall of the outlet box in accordance with I the instalation inskuctions supplied with the product. E Installation to comply with Article 370-16 of the National Lccha Stop Inserb for use with max 2-ll8 by 4 by 2-118 deep. flush device UL Listed Metallic Outlet Boxes without clamps in 2 h fire rated gSpsum wallboard wall assemblies framed with rnin 3-l/2 m. de€p streel shrds and fl Uecticat Code, (NFPA 70). Outlet boxee installed with steel N ^^-.- -r^.^- rrrl- -^r^^.:-.^ --a^-:^r :^..^^J *.:rL:3 ^-,rrJcover plates. Whe,n protective material is used within outla Bioctop Lecha Stop lnrerb for use with max 4-l/2 by 8-l/2 by l-5/8 in deep . flush device UL Listed Metallic Otrtlet Boxes witbout internal clamps in 2 br fire rated gpsum wallboard wall assemblies framed with rnin 3-l/2 in-deep steel studs and construsGd of the materials and in the manner specified in the individual U,mO Series Wall and Partition Designs i1 gfe 5i. Directorry. Two 9{ mm wide by 95 rnn high inserts are spaced and adhered to the interior back wall ofthe outlet box in accordance with tbe installation instructio$ supplied with the product Installatiou to comply with Article 370-16 of the National Electrical Code NFPA 70). Min 3i4 in. deep plaster rings installed over outlet bor After installation of glpsum wallboard, nm l/4 in. thickness ofRectorSeal Biostop 50Gr Sealanl bearing the UL Classification Marting for Filt Void or Cavity Materials, applied between the base l,ayer of wallboard and the plaeter ring. Outlet boxes installed with steel cover plates. When orotective material is used within and around outlet boxes box protective material and fill mderial are used on boxes on both sides ofwall as directed" the horizontal separation between outlet boxes on opposite sides ofthe wall may be less than 24 ia. provided that the boxes are aot insta[ed bsck-to+ack Biootop lfre Rrted Putty Padr for use witt max aby 3-314 by 3 in deep UL Listed Noneetallic Outlet Boxes manufactured by Carlon Electrical Products, made from polyvinyl chloride, and bearing a 2 br rating under the "Outlet Boxes and Fittings Classified for Fire Resistancen category in the Fire Resishce Directory. Putty pads and boxes for use in I and 2 hr firo rded gypsum wallboarrd wall assemblies framed with rnin 3-12 in. deep y/ood shrds md constucted of the materials and in lhe manner specitred in the individrlal U300 Series Wall and Partition Desigos in the Fire Resistance Directory. Outlet box secured to wood stud by mgnns 6f twq aailing tabs in conjunction wit nails sryplied with the outlet bo;c Min l/8 in. &ick moldable putty pads are to be installed to completely cover the exteric surfac€s of the outlet box (except for the side ofthe orflet box aginst the stud) including the nailing tab and completely seal against the stud within the shrd cavity. Outlet boxes installed with steel or plastic cover plates. Whe,n moldable 1nrdy pad outlet box protective mat€rial is used on boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides ofthe wall may be less than 24 in provided that the boxes are not installed back{o'back. UL does not fumi$ a detail drawing futhese listings ODELL ARCHITECTS PC Date: Project : Owner: To: February l7,2004 Middle Creek Affordable Housing 129 North Frontage Road. Vail, Colorado 81657 Coughlin and Company 140 E. l9'" Ave., Suite 700 Denver, CO 80203-1035 Shaw Constn"rction 760 Horizon Drive Grand Junotion, CO 81506 Attn: Keith Oxenreider ASI No: Date of lssuance: 0012 February 17, 2004 Architect: Odell Architects, P.C. 32065 Castle Court, Suite 150 Evergreen, Colorado 80439 Phone: 303-670-5980 Fax: 303-670-7162 Project No.: 0210 The following Architect's Supplemental Instructions is issued to modif or interpret the contract documents, including the Drawings and Specifications. Please contact the Architect upon receipt of this ASI. Architect's Supplemental Instructions No. 012 is being issued to supplement the permit Drawings, dated: June 10,2003. See attached sketches. This information will be incomorated into the final Construction Documents. Item: ASr-012.1 ASI-012.2 ASI-012.3 ASI-012.4 Wall type 12 - Wood studs do not need to be non-com. - See sketch. Wall type 2l - Wood studs must be non-com. - See sketch Wall type 29 - Studs are 2x6. - See sketch. Framer has suggested a different detail at the walkway location. Please confirm with Charlie Davis that this meets 2 hr. construotion requirements. We are still going to run in by Gillans for their opinion on the water penetration aspect. H:\Projects\3 -02- I 0\021 0\GA\ASIs\ASt-0 I 2.doc + f ODELL AN,CEITBCTS, P.C, Arcrtrrwgtt Plrrrrrc Itrrnlom fl6ri c{g|E qur, Iuf ts olxfia ofim nal Iddtoc S$nSO fotrr sl't'r0710 Middlc Creek Affordable 129 North Frontage Road Vail, Colorado 81657 mo,fcr N0. 0210 DAIE: FSruory 17, 2001 ORAhING NO sK.l2.0l oo + + + + O4{N - IHIN VTNEIR STOtiT O.T2OO _ METAL LAIH - BUILDNG IIL$ 07200 - BAIT INSUIAII0N; Rl9 09200 - 2 LAYERS GYP, BD.; 5/8' lYPt X |.JL# tji01 IVALL TYPT 21 2 HOUR RATED ++ ODBLL ATCEITBCTS, P.C. Arcrr?rcrsrt Plrrtrre lirttro$ J& Cr t mnr, rmfio nBnEr ccn m ixt Idrtrc lftn5m f!d* J0I6nI62 Middle Creek Affordable 129 North Frontagc Road Vail, Colorado t1657 PR0fcT it0. 0210 DAIE: Februory 17, 2001 DRAIIII'IG t'lo sK.l2-02 + + OllOO - THIN VINEER STONE, EACH SIDE O42OO - llElAL LAIH. TACH SIDT uL# tJJs6 WALL TYPE 29 1 HOUR RATID ++ ODBtt ARCf,ITBCTS, P.C. Atcltrtcrurr Purtne lntrtor' IG Crflf COX[, Snt 150 na&E c0-0[,m |I Ud'!c $GnlD fd3 t0lt['|ll Middle Creek Affordable 129 North Frontage Road Vail, Colorado 81657 mGtcT ilo. 0210 DAIE: Fehuory 17, 2001 oRAfltiG ftO sK.12.03 / ) I + + O6IOO - V{OOD FRAMING; ()OOO(} - MiT, FLASHING; O0OOO - CAUTK BEAD; 06100 - lV00D DECKING; 3x OOO() - MIL. FLASHING: 09200-GYP, BD: llorer 5/8', Tpe X' 0920-3 C0AT SIUCCO SNTEM DETAIL @ VI/ALKIVAY SCALT: 1'=l'-0' ODEtt ATCEIIECTS, P.C. Alclntctutr PLrrrtle hrrrlorr tr6C SUOU[,l|[rS noflg Con m orlI-trc lE6T0!m fd. Ilt[7llt Middle Creck Affordablc 129 North Fronage Road Vail, Colorado 81657 PRo.tcT N0. 0210 OAIE: Februory 17, 2fi4 DRAfft{o ilo \ sK.12.04 oa 092m - GYPS[/I{ B0IRD; s/E" rype ^ 06t$ - ||00D FRAM|NO; 2x6 OOOOO - PRE-ENGINEERED S]TEL STAIR SlRINGTR mom - coilcRtTt sTAtR ]READ 092ffi - GYPSUM BOARD:l/d tule x . oilhered' to stiinger OOOffi _ FIRI CAUI.I; 072m-i coAT sTucco SYSIEll,| DETAIL SCAIE l'=1'-0' From: Charlie DavisTo: lmason@odellarchitects.comDate: 0812612003 1:38:16 PMSubject: Fwd: Middle Creek Comments Poet tcffiilr+ C.na n7A . ^rt Sxutsrt;r't9ru-"' d[v- ,^t-{J tfuut NtbP oFl q l>f2 tlLNt Ntb Lee I am forwarding the comments that have been generated by the Fire Dept after review of your last set 1ficcr#.w- -,,*k. tppto6ryINStvlLzT) u of response received by us on 8121103. l'll respond here to how these items shall be handled ATTIC ACCESSES Building A & B will not be installing sprinklers into the attic, Mike and I agree that NO access shall be provided to these attics to completely discourage these spaces from being used as storage. I would like to M$JZ also discourage the use of the attic spaces for any electrical or mechanical equipment installationfThese systems should be found a home somewhere else on the property. Building C will have sprinklers installed in the attic spaces, access to the attic is required for maintenance and inspection only. A 22"x 30" wide access will be acceptable. lf mechanical or electrical systems are to be installed in the attic, then a 3' x 4' eccess will be required. I would also discourage the use of the attic for any mechanical or electrical syslems in Building "C's'' attic for many reasons. Access to mechanical- AIbAt, equipment, permanent access(ladders) , and location of accesses, structural issues, etc.... will need to be resolved. Be aware that any access opening shall be protected as a 60 minute fire assembly per 97 UBC sec-710.2 for through penetrations of fire-resistive assemblies. STAIR TOWER VENTILATION. Mike and I have agreed to let the design be approved as submitted subject to a performance test per 97 UBC sec.-104.2.9. This test shall be performed per this code section and shall not be at the cost of the jurisdiction. Prior to occupancy of these units the test methods shall be discussed and the performance test completed to our satisfaction. lt may be helpful if your Fire-Protection-Engineer of record is employed to determine an acceptable test method to prove,?:r1lT"[:r_?B.J lff+, O* ,/OAREA SEPARATION WALL UL 901 Accepted as submitted with minor change, all firring materials shall be fire-retardant-treated-wood or non-combustible materials. Proper draft-stopping in the void spaces or submit something from UL showing that combustible materials applied to the 901 design will not compromise the wall assembly. I am conservative here for a reason. This area separation wall is critical to allow the size and construction type of the building to be constructed as submitted and want to be sure that this assembly will perform as expected. There are many different exceptions and alternatives being employed here to get this project to the construction phase.Ck w)LL l. 2f v) EXCEPTIONS TO NFPA 13 We (Town of Vail) reserve the right to review sprinkler system design and interpret what if any exceptions apply. The sprinkler design should be submitted to us for review at the earliest opportunity to resolve any problems and not delay this project during construction As I mentioned earlier today, I will be meeting with our plan review consultant (Art) tomorrow afternoon and should have a complete formal response of Building Code items by Thursday afternoon back to you. Thanks Charlie Davis Building Official Town of Vail Mike McGee: Nina Tlmm: Russ ForrestGC: soL-\)vo s l, ufos From: To: Date: Subject: GC: Forrest Mike McGee Charlie Davis 0812612003 9:47:22 AM Middle Creek Comments I have reviewed the comments made in response the Vail Fire Department's review of the plans. The short response is we do need to see the building ptans.ff The issue of attic access hatches with respect to location, number and size has not been adequately addressed in the response. We do not oppose the issuance of a permit but the specifications in Section rt seryice mechanical or electrical equipment." The demenisions "as indicated_ u||rudlturtb roeuu(J ^ ,I luired to properly ^ " ,V 5 " o small to allow *' 08310, Part 2, Subsection 2.01 D. Sizes, states " As indicated on drawings or as required to properly access by emergency personnel in protective clothing and air pack No6c.:ro # 1" calculations for the stairtower still do not address the vent. t sugEst !" continuetousethisdesign. J $nfoA,Wttttt fesf -iest we require a smoke test if we The cut sheets for the U.L 901 wall assembly was not submitted. A cut sheet for Design U804 and UE08 was supplied. lf the Building Dgpt is OK with documentation of the assqmbly, we will withdraw our :"#i#;'.:*{* "":#;,3^ "!;, ^f:i":,sw '--ro Q p r ar6 ryedtobereviewed.:b Summary: The building permit is OK for release. Vail Fire & Emergency Services will need to continue review and discussion with the Building Dept. in the interest of resolving some outstanding issues. Allison Ochs; George Ruther; John Gulick; Mike Vaughan; Pam Brandmeyer; Russ \O Bvry fla h-b No,.[tt€'9 s?etu bWS '"" WorJ{o @ B'tuort,.-tb C !a Ea''' Q Sl\ntkcr,ilf| ,t - :ii 3rtLfi6€- w^''3'H,.;ru.''uy,lf," @) r) d 'ilDl:ys 3lq'tP'* "y6e,Jrw.eo'' ffi ,Sn lrtm,q a 2oo2 FIRE REstsrANcE DIREcToRYO 0l3O FIRE RESISTANCE RATINGS - ANSUUL 263 (BXUV) Deaign No. U804 (Exposed To Fire On Spray-Applied Fire Reeistive Material Face Only)- Nonbearing WaU Ratings - 1, 1'7J2,2,3 or 4 EIR- (See ltem 5) F|RE RESTSTANCE RATTNGS - ANSUUL 26il (BXUV) Design No. U808 (Exposed To Fire On Interior Face Nonbearing wall rating - 1-1/2 or 2 tlr. Design No, U901 Bearing Wall Bating - 4 HR. Nonbearing Wall Rating - 4 HR. Only) (S€e Item 5) 1. Supporting Angles - I3l8by3-3/8by1/4in'steel angles placed alonq top and bottom of wall, aftached to masonry with l/4 in. dram. bv l:1ti n.lons nailable fasteners with lead plugs spaced 24 in OC; 2 bl2bv gtl6 inJsteel aneles placed along sid6s oT asltmbly, attached to niasoniy with 5/16 in. diam. by 2-112 in: long steel lag bolts with steel expansion shields spaced 5 ft OC. 2. Flishing Anglea-'Min. No.24 GSG galv steel formed into a Z profile with 1 iird 111/2 in. lees and 2 in. web-, located along top and bottom of wall, l-l /2 in. leg aEached to facing units. Angles attdchea to masonry with 1/4 i-n. diameter by 1-172 in. long nailable lastener with lead oluss spaced ,{0 in. OC. g. facin:s linid- - Steel facing unib min. No.24 GSG galv steel min L-L ll-in. deep, supplied in ;in. 24 in. widths, Classifiid by Underwnt- ers Laboratories Ina' Gt€ Resistanc€ Dt€ctrory, "wall and Partition Fac- inqs and Accessories" ). Attadred to support angles and reinlorcing dr"annel th-roueh flashing angles with 174 ir. diam. by 3/4 in. long hex head self+app-ing steel s-crews located in every flute in the horizontal d.i,rection ard spiced approx. 20 in. OC at sid-es and lap joints. CEruf nH -Tvoe"'Huski-Rib Sheet'" 3.A. Altemate Facing Uniia* - Steel facing units min. No. 26 GSG galv steet., min I 1/2 in. deep with max.3 h. wide flutes, supplied in widths, Classified bv Underwriters Laboratories Inc. (Fire Resistance Directory "Wall anri Partition Facings and Accessories" ). Attached to support'ansles and reinforcins channel through flashing angles with 1/4'in. dia;. bv 3/4 in. lonq f,ex head seU-taiping stee-i screws located in every flute ii the horizonial direction and ifaced approx. 20 in. O.C. at sides and lap ioints. 4. Reinlorcing Channel - C8 x 11.5 cold-rolled steel rlannel spaced 5 ft O.C. aftach;d to 2 by 2 by 3/ 15 in. steel angle with two 1/4 in. diam. bv 11/2 in. lone bolls ani nuts at each end. The argles were attached tri side of maso"nry by two 5/16 in. diam by 2712 i.i. long steel lag bolts with steel eipairsion shields at each end. 1. Facing Units - Nom 36 in. wide by mh No. 29 MSG thick coated steel;nits with nom 1-314 in. majoi ribs spaced 9 in. OC and nom 3/4 in. stiffening ribs spaced 3 in. OC. 2. Steel Coluin - Min Se Uv 12.5 steel column loaded to a max of 18 Dercent of its pennissible carrying capacity. 3. bteel Angles - Min 1-314 bi 1-3l4 by 3i 16 in. thick steel argles welded along the web of the column every 48 in. OC. 4. Wood Girts a Norr 2 bv 6 in. wood members spaced 48 in. OC and secured to the horizontal leg o( the steel angle by mears of two nom 3 / 16 in. diam by 2 ln. Iong& +apping hexihead screws with I /4 in. diam formed steel washers. 5. FaEteners - Nom3/15in.diamby1-1/2in. long self-tapping hex- head screws with 1/4 in. diam formed steel washer and rubber washer spaced approx 5 in. OC to secure the vertical seams of the facing units tAgether. Additional screws spaced aPPrcx 9 in. OC to secure facing units to wood girt. 6. Spray-AppliedFire Resisti_ve Matedals* - Sprayed with TyP: A-?3 adhesive in accoldance with application instruchons to a mm dry den' sity of 11.0 pcl For method ofdensity determinatiorL refer to Design lniormation Section. Tf the steel column is a bearing member the mir material thickness required on the facing units, steel column and wood girts are shown in the table below:- REQUIRED MIIITERIAL THICKNESS, IN, ti! FacingRrtinc unitl-u' t1l224 Ste€l Cotufrn T1l2 Tr12 AMERICAN SPRAYED FIBERS INC -TYPC DDM *Bearing the UL Classification Mark Wood Gide 2 2 Spray-Applied_Fiie Resistive. Materiale . .- ,Apelf by spl3YTrg wth water into rcinJorcrnq channel and one srde ot the war to nnal untamped thicknesse-s shown below. Surfaces are to be free of dirt, oil and scile. Use oI adhesive is required. Tamping is optional. Min avg density of 13 pd with nin ind density of 1l pcl for l}pes II or DC/F. s€ctlon. ClErsiication llt 1 1-112 2 3 Min ais and inin ind densities of 22 and' 19 ird, respectively, for Type F{P. FoiMethod of densitv determinatio[ refer to general informationof densitv determination refer toefer to gi:neral iriformation 1. Concrete Block'- Various design6. Classi-frcation 84 (4 hr)' See Concrete Blocks category for lists of eligrble manufactue$' .,^, 2. Mortar - Blocks laid in "fuf Uea of morta!"nom.3/8 in. thick, of,not- i!" tr'"" z-17+ li'J;ot ;; th,."3-i / i;;;;i.i!;;h"'P'l.'d ?.' Dart Portland cement (proporhonei ui tdr"t"i -J *i mtjle than $ inrcent hydrated lime '(by cement volirme). Vertical jornts lfq€fit# rc3. Portland Cement Stucco or GyPsum Plaater - lf used, add l// ru' Classification. 4. Loose Masonrv Fill - If alt core spaces are filled with loose drY -^r "^p*d"a Jidu"^"d clay or shal! (rctary kiln proc€st,. water t€Per la.rit vermiculite masonry fill insulatio& ofsilicorie heated Petl,te-: fill insulatiory Class D-2 (2 hr) or C-3 (3 hI) concrete blocks wm v'- vide a 4 hr fire resistance rating. *Bearins the UL Classification Maik Mtl Thknc In F.cing Unit 2 2-3116 u3l16 $13/16 4.7 116 Retnforcing Charmel 1 1-'t l2 t-15116 2-r l4 241't6 CIL GROUP LTD -Type D-C/F or TyPe II. Type EBS adhesive/ 6ealer, ISOLATEK INTERNATIONAL -Type D-C/F, HP or Type tr' LOOK FOR THE UL MARK ON PRODUCT Type EBS adhesi ve / sealer. 'Bearing thd LtL Classification Mark