Loading...
HomeMy WebLinkAboutB12-0382 FORD AMPHITHEATERTOWN OF VAIL% Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970 - 479 -2128 www.vailgov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: 530 S. Frontage Road (Number) (Street) (Suite #) Building /Complex Name: Gerald R. Ford Amphitheater Contractor Information Business Name: TBD Business Address: City State: Zip: Contact Name: Contact Phone: Contact E -Mail: I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review ap- proved, International Building and Residential Codes and other ordinances of the,rfown applicable thereto. X t- Owner /Own,6r's Representative Signature (Required) Applicant Information Applicant Name: Jack Hunn, Owner's Representative Applicant Phone: 970.390.4537 Applicant E -Mail: jackhunn @yahoo.com Project Information Owner Name: Vail Valley Foundation Parcel #: 210108100002 (For Parcel #, contact Eagle County Assessors Office at (970- 328 -8640 or visit www.eaglecounty.us/patie) For Office Use Only Fee Paid: Received From: Cash Check # CC: Visa / MC Last 4 CC # Auth # exp date: Project #: prW % �0 (D DRB #: Building Permit #: Lot #: Block # Subdivision: QtJ PLfFiTE�0 Work Class: New 0 Addition O Alteration Type of Building: Single - Family 0 Duplex () Multi - Family 0 Commercial 1F Other 0 Work Type: Interior Q Exterior O Both I\Z Valuation of Work Included Plans Included Work Electrical ('-"Yes O)No (F)Yes ONo 24000 Mechanical Yes O)No (�i Yes ONo 16000 Plumbing Yes 0No G)Yes 0No 52000 Building ( Yes O)No Yes ONo 350000 Value of all work being performed: $ 442000 (value based on IBC Section 109.3 & IRC Section 108.3) Electrical Square Footage 1,050 Detailed Scope and Location of Work: The project includes the construction of a new accessory restroom building, and limited improvements to the existing buildings. Site improvements to the lawn seating areas and construction of a new terrace are also included. (use additional sheet if necessary) Date Received: AUG 21 &7v t✓'` TOWN OF VAIL 12- Mar-2012 COMcheck Software Version 3.9.0 Interior Lighting Compliance Certificate 2009 IECC Section 1: Project Information Project Type: New Construction Project Title : Ford Park Amphitheater Lower West Restroom Construction Site: Owner /Agent: Section 2: Interior Lighting and Power Calculation Designer /Contractor: A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts / ft2 (B x C) East Restrooms (Performing Arts Theater) 762 1.6 1219 Stage Left Restrooms (Performing Arts Theater) 1652 1.6 2643 Total Allowed Watts = 3862 Section 3: Interior Lighting Fixture Schedule A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B C D E Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. East Restrooms ( Performing Arts Theater 762 sq.ft.) Incandescent 1: D: LED downlight / Incandescent 20W 1 19 20 380 Linear Fluorescent 1: F: Linear fluorescent perimeter / 48" T8 32W (Super T8) / Electronic 1 12 32 384 Stage Left Restrooms ( Performing Arts Theater 1652 sq.ft.) Incandescent 2: D: LED downlight / Incandescent 20W 1 30 20 600 Linear Fluorescent 2: F: Linear fluorescent perimeter / 48" T8 32W (Super T8) / Electronic 1 40 32 1280 Total Proposed Watts = 2644 Section 4: Requirements Checklist Lighting Wattage: F1 1. Total proposed watts must be less than or equal to total allowed watts. Allowed Watts Proposed Watts Complies 3862 2644 YES Controls, Switching, and Wiring: i] 2. Daylight zones under skylights more than 15 feet from the perimeter have lighting controls separate from daylight zones adjacent to vertical fenestration. ❑ 3. Daylight zones have individual lighting controls independent from that of the general area lighting. Exceptions: ❑ Contiguous daylight zones spanning no more than two orientations are allowed to be controlled by a single controlling device. ❑ Daylight spaces enclosed by walls or ceiling height partitions and containing two or fewer light fixtures are not required to have a separate switch for general area lighting. I] 4. Independent controls for each space (switch /occupancy sensor). Exceptions: Project Title: Ford Park Amphitheater Lower West Restroom Report date: 08/01/12 Data filename: P: \Current Projects \12029.00 - Ford Park Lower Bench & East Ampitheater Restrooms \Calculations \COMcheck \2012 -0801 COMCHECK.cck Page 1 of 4 ❑ Areas designated as security or emergency areas that must be continuously illuminated. ❑ Lighting in stairways or corridors that are elements of the means of egress. ❑ 5. Master switch at entry to hotel /motel guest room. ❑ 6. Individual dwelling units separately metered. ❑ 7. Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent of the control of the nonexempt lighting. ❑ 8. Each space required to have a manual control also allows for reducing the connected lighting load by at least 50 percent by either controlling all luminaires, dual switching of alternate rows of luminaires, alternate luminaires, or alternate lamps, switching the middle lamp luminaires independently of other lamps, or switching each luminaire or each lamp. Exceptions: ❑ Only one luminaire in space. ❑ An occupant- sensing device controls the area. ❑ The area is a corridor, storeroom, restroom, public lobby or sleeping unit. ❑ Areas that use less than 0.6 Watts /sq.ft. ❑ 9. Automatic lighting shutoff control in buildings larger than 5,000 sq.ft. Exceptions: ❑ Sleeping units, patient care areas; and spaces where automatic shutoff would endanger safety or security. ❑ 10.Photocell /astronomical time switch on exterior lights. Exceptions: ❑ Lighting intended for 24 hour use. ❑ 11.Tandem wired one -lamp and three -lamp ballasted luminaires (No single -lamp ballasts). Exceptions: ❑ Electronic high- frequency ballasts; Luminaires on emergency circuits or with no available pair. Section 5: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2009 IECC requirements in COMcheck Version 3.9.0 and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date Project Title: Ford Park Amphitheater Lower West Restroom Report date: 08/01/12 Data filename: P: \Current Projects \12029.00 - Ford Park Lower Bench & East Ampitheater Restrooms \Calculations \COMcheck \2012 -0801 COMCHECK.cck Page 2 of 4 COMcheck Software Version 3.9.0 Exterior Lighting Compliance Certificate 2009 IECC Section 1: Project Information Project Type: New Construction Project Title : Ford Park Amphitheater Lower West Restroom Exterior Lighting Zone: 2 (Neighborhood business district) Construction Site: Owner /Agent: Designer /Contractor: Section 2: Exterior Lighting Area /Surface Power Calculation A B C D E F Exterior Area /Surface Quantity Allowed Tradable Allowed Proposed Watts Wattage Watts Watts / Unit (B x C) East Restrooms (Main entry) 6 ft of door width 20 Yes 120 60 Total Tradable Watts* = 120 60 Total Allowed Watts = 120 Total Allowed Supplemental Watts ** = 600 * Wattage tradeoffs are only allowed between tradable areas /surfaces. ** A supplemental allowance equal to 600 watts may be applied toward compliance of both non - tradable and tradable areas /surfaces. Section 3: Exterior Lighting Fixture Schedule A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. East Restrooms ( Main entry/exit 2 ft of door width): Tradable Wattage Incandescent 1: D: LED recessed downlight / Incandescent 20W 20 60 East Restrooms ( Main entry 6 ft of door width): Tradable Wattage Total Tradable Proposed Watts = 60 Section 4: Requirements Checklist Lighting Wattage: 1. Within each non - tradable area /surface, total proposed watts must be less than or equal to total allowed watts. Across all tradable areas /surfaces, total proposed watts must be less than or equal to total allowed watts. Compliance: Passes. Controls, Switching, and Wiring: ❑ 2. All exemption claims are associated with fixtures that have a control device independent of the control of the nonexempt lighting. Lj 3. Lighting not designated for dusk -to -dawn operation is controlled by either a a photosensor (with time switch), or an astronomical time switch. 4. Lighting designated for dusk -to -dawn operation is controlled by an astronomical time switch or photosensor. 5. All time switches are capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. Exterior Lighting Efficacy: ❑ 6. All exterior building grounds luminaires that operate at greater than 100W have minimum efficacy of 60 lumen /watt. Project Title: Ford Park Amphitheater Lower West Restroom Report date: 08/01/12 Data filename: P: \Current Projects \12029.00 - Ford Park Lower Bench & East Ampitheater Restrooms \Calculations \COMcheck \2012 -0801 COMCHECK.cck Page 3 of 4 Exceptions: ❑ Lighting that has been claimed as exempt and is identified as such in Section 3 table above. J Lighting that is specifically designated as required by a health or life safety statue, ordinance, or regulation. ❑ Emergency lighting that is automatically off during normal building operation. LJ Lighting that is controlled by motion sensor. Section 5: Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2009 IECC requirements in COMcheck Version 3.9.0 and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date Project Title: Ford Park Amphitheater Lower West Restroom Report date: 08/01/12 Data filename: P: \Current Projects \12029.00 - Ford Park Lower Bench & East Ampitheater Restrooms \Calculations \COMcheck \2012 -0801 COMCHECK.cck Page 4 of 4