Loading...
HomeMy WebLinkAboutA12-0047 CUT SHEETSJCI-6935:D • 12/07/2011 — Page 1 of 2 2951J(A) Series Intelligent Plug-In Photoelectric Smoke Detector with FlashScan® JCI-6935:D General Johnson Controls intelligent plug-in smoke detectors with integral communication provide features that surpass conventional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector’s address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. The 2951J(A) photoelectric detector’s unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-temperature thermal sensing on the 2951TJ(A). The 2951JR(A) is a remote test capable detector for use with DNR(A)/DNRW duct detector housings. 2951J(A) and 2951TJ(A) detectors are compatible with Johnson Controls Intelligent Fire Alarm Control Panels (FACPs) in CLIP or FlashScan® mode. FlashScan® (U.S. Patent 5,539,389) is a communication protocol that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices in the group has new information, the panel’s CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features •Sleek, low-profile design. •Addressable-analog communication. •Stable communication technique with noise immunity. •Low standby current. •Two-wire SLC connection. •Compatible with FlashScan® and CLIP protocol systems. •Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). •Optional remote, single-gang LED accessory. •Dual LED design provides 360° viewing angle. •Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm (FlashScan systems only). •Remote test feature from the panel. •Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1(FlashScan systems only). •Built-in functional test switch activated by external magnet. •Built-in tamper-resistant feature. •Sealed against back pressure. •Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appearance. •94-5V plastic flammability rating. •SEMS screws for wiring of the separate base. •Optional relay, isolator, and sounder bases. Specifications Sensitivity: 0.5% to 2.35% per foot obscuration Size: 2.1" (5.3 cm) high; base determines diameter. –B210LP(A): 6.1" (15.5 cm) diameter. –B501(A): 4.1" (10.4 cm) diameter. –B200S(A): 6.875" (17.46 cm) diameter. –B200SR(A): 6.875" (17.46 cm) diameter. –B224RB(A): 6.2" (15.748 cm) diameter. –B224BI(A): 6.2" (15.748 cm) diameter. Shipping Weight: 5.2oz. (147g). Operating Temperature range: 2951J(A), 0°C to 49°C (32°F to 120°F). 2951TJ(A), 0°C to 38°C (32°F to 100°F). Low temperature signal for 2951TJ(A) at 45°F +/- 10°F (7.22°C +/- 5.54°C). 2951TJ(A) installed in a DNR(A)/DNRW, -20°C to 70°C (-4°F to 158°F). UL/ULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/ min.), suitable for installation in ducts. Relative Humidity: 10%-93% noncondensing. Thermal Ratings: Fixed-temperature setpoint 135°F (57°C). DETECTOR SPACING AND APPLICATIONS Johnson Controls recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.144m) for ceiling heights 10 feet (3.148m) and higher. For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, document A05-1003, is available at systemsensor.com ELECTRICAL SPECIFICATIONS Voltage Range: 15-32 volts DC peak. Standby Current (max. avg.): 300μA @ 24VDC (one communication every five seconds with LED enabled). LED Current (max.): 6.5mA @ 24 VDC (“ON”). 2951J(A) in B210LP(A) Base B210-2951.jpg Page 2 of 2 — JCI-6935:D • 12/07/2011 FlashScan® is a registered trademark of Honeywell International Inc. ©2011. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Johnson Controls Field Support Center. 507 East Michigan Street, Milwaukee, WI 53202 www.johnsoncontrols.com Made in the U.S. A. Installation 2951J(A) plug-in detectors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug in and remove detectors without using a ladder. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see JCI-60056. NOTE: 1) Because of inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Style 4 (Class “B”) wiring. 2) When using relay or sounder bases, consult the M500XJ(A) installation sheet I56-1384 for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. •UL Listed: S1948. •ULC Listed: S1948. •MEA Listed: 225-02-E Vol.3 . •FM Approved. •CSFM: 7272-0554:0145 . •Maryland State Fire Marshal: Permit # 2136 . Product Line Information NOTE: “A” suffix indicates ULC Listed model. 2951J: Low-profile intelligent photoelectric sensor. Must be mounted to one of the bases listed below. 2951JA: Same as 2951J but with ULC listing. 2951TJ: Same as 2951J but includes a built-in 135°F (57°C) fixed-temperature thermal device. 2951TJA: Same as 2951TJ but with ULC listing. 2951JR: Low-profile intelligent photoelectric sensor, remote test capable. For use with DNRA/DNRW. 2951JRA: Same as 2951JR but with ULC listing. For use with DNRA. INTELLIGENT BASES NOTE: “A” suffix indicates ULC Listed model. NOTE: For details on intelligent bases, see JCI-60056. B210LP(A): Standard U.S. flanged low-profile mounting base. B210LPBP: Bulk pack of B210LP; package contains 10. B501(A): Standard European flangeless mounting base. B501BP: Bulk pack of B501; package contains 10. B200S(A): Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw terminals: up to 14 AWG (2.0 mm²). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. B224BI(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases . ACCESSORIES F110: Retrofit flange to convert B210LP(A) to match the B210LPJ(A) profile, or to convert older high-profile bases to low-profile. F110BP: Bulk pack of F110; package contains 15. F210: Replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B210LP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-127-010: Detector removal tool without pole. BCK-200B: Black detector covers for use with 2951J(A) only; box of 10. WCK-200B: White detector covers for use with 2951J(A) only; box of 10. Description The Wheelock Series E Low Profle Speakers and Speaker Strobes are designed for high effciency sound output, with dual voltage (25/70 VRMS) capability and feld selectable taps from 1/8 to 2 watts. The low profle design incorporates a speaker mounting plate for faster and easier installation. Each model has a built-in level adjustment feature and an aesthetic two (2) screw grille cover. The Series E Speaker Strobe models incorporate the Low Current draw Series RSS Strobes. Strobe options for wall mount models include 1575 or Wheelock patented MCW multi-candela strobe with feld selectable candela settings of 15/30/75/110cd or the high intensity MCWH strobe with feld selectable 135/185cd. Ceiling mount models are available in Wheelock patented MCC multi-candela ceiling strobe with feld selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. Series E Speakers and Speaker Strobes provide high audio output with clear audibility and are designed to meet the critical needs of the life safety industry for effective emergency voice communications, tone signaling and visible signaling to alert the hearing impaired. The strobe portion of all Series E Speaker Strobes may be synchronized when used in conjunction with the Wheelock DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Wheelock synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy. Series E Speaker Strobes are UL Listed for indoor use under Standard 1971 (Signaling Devices for the Hearing-Impaired) and Standard 1480 (Speaker Appliances), and use a Xenon fashtube with solid state circuitry enclosed in a rugged Lexan® lens to provide maximum reliability for effective visual signaling. All inputs are supervised and employ IN/OUT wiring terminals for fast installation using #12 to #18 AWG wiring. Color options for the Series E Speakers and Speaker Strobes are red, white and nickel plated. Features • Approvals include: UL Standard 1971, UL Standard 1480, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM) and Chicago (BFP) See approvals by model in Specifcations and Ordering Information • ADA/NFPA/ANSI compliant • Complies with OSHA 29 Part 1910.165 • Wall mount models are available with Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd (Multi- Candela models), or 1575cd (Single Candela model) • Ceiling mount models are available with feld selectable candela settings of 15/30/75/95cd or 115/177cd (Multi- candela models) • Strobes produce 1 fash per second over the regulated voltage range • 24 VDC with wide UL “Regulated Voltage” using fltered DC or unfltered VRMS input voltage • Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol • Field selectable taps for 25 or 70 VRMS operation from 1/8 watt up to 2 watts • High effciency design for maximum output at minimum wattage across a frequency range of 400 to 4000 HZ • Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires SERIES E70 STROBE SERIES E90 SPEAKER Series E70 Speakers and Speaker Strobes THE CITY OF NEW YORK DEPARTMENT OF BUILDINGS UL® 151-92-ES5391 7125-0785:152 7320-0785:134 (Speaker) SERIES E90 STROBE SERIES E70 SPEAKER Notifcation Table 1: UL Max Current* E70/E90 Speaker Strobes E70 Strobe Current - Wall MountE90 Strobe Current - Ceiling Mount 241575W24MCW24MCWH24MCC24MCCH 1575cd15cd30cd75cd110cd135cd185cd15cd30cd75cd95cd115cd177cd 16-33 VDC0.0900.0600.0920.1650.2200.3000.4200.0650.1050.1890.2490.3000.420 Table 2: E70/E90 UL Reverberant dBA @ 10 Feet** watts1/81/41/212 E Speaker7781838689 E Speaker Strobe 7680828588 **dBA ratings are based on testing under UL Standard 1480. * UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfltered FWR ratings, see installation instructions. NOTE: All CAUTIONS and WARNINGS are identifed by the symbol . All warnings are printed in bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to fash at 1 fash per second minimum over their “Regulated Voltage Range”. Note that NFPA-72 specifes a fash rate of 1 to 2 fashes per second and ADA Guidelines specify a fash rate of 1 to 3 fashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • “Regulated Voltage Range” is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology “Listed Voltage Range”. Series PS Power Supplies Series PS Power Supplies EOLR F A C P OUTPUTS 1-4 4-CLASS "B" OR 2-CLASS "A" E E E ST ST ST DSM + OUT 2 +OUT 1 + IN 1 + IN 2 MINUS 1 MINUS 2 + - - + SYNC AUDIBLE STROBE NAC CIRCUIT OUT STROBE NAC CIRCUIT RETURN FACP EEE EEE F A C P DSM #3Audible NAC Cir. Strobe NAC Cir. DSM #2 DSM #1 Strobe NAC Cir. Strobe NAC Cir. Audible NAC Cir. Audible NAC Cir. EE EE EE Sync Sync Sync + -+ +- - DSM Interconnecting wiring shown. Maximum of twenty (20) Wiring Diagrams# For wiring information on the Wheelock power supplies, please refer to Data Sheet #S9100. SERIES E SPEAKER & STROBE OPERATE INDEPENDENTLY (NON-SYNC OR SYNC) SERIES E SPEAKER STROBES SYNCHRONIZED WITH MULTIPLE DSM MODULES SERIES E SPEAKER STROBE APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS “A” SERIES E SPEAKER STROBE APPLIANCES & RSS STROBES SYNCHRONIZED WITH WHEELOCK POW- ER SUPPLIES Note: Figure shows intercon- nection to strobe through sync module. Speaker portion requires 2 separate conduc- tors to FACP. # For detail using DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84905. TO NEXT APPLIANCE OR EOLR FROM PRECEDING APPLIANCE OR VOICE EVACUATION PANEL TO NEXT STROBE OR EOLR FROM PRECEDING STROBE, SYNC MODULE, POWER SUPPLY OR FACP SPEAKERSTROBE +-+ + - - -++ + - - Model Order Code Wall Mount Ceiling Mount Strobe Sync w/ DSM or Wheelock Power Supplies Strobe Candela Model Color RED Model Color White Model Color Nickel Mounting Op- tions Agency Approvals ULMEACSFMFMBFP E70-24MCW-FR9022X-X15/30/75/110X--L,O,P,Q,R,U,YXXXXX E70-24MCW-FW9023X-X15/30/75/110-X-L,O,P,Q,R,U,YXXXXX E70-24MCW-FN3099X-X15/30/75/110--XQ,UXXXXX E70-241575W-FR7871X-X15 (75 on Axis)X--L,O,P,Q,R,U,YXX-XX E70-241575W-FW7876X-X15 (75 on Axis)-X-L,O,P,Q,R,U,YXX-XX E70-241575W-FN3100X-X15 (75 on Axis)--XL,O,P,Q,R,U,YXX-XX E70-R7866XX--X--Q,UXXXXX E70-W7868XX---X-Q,UXXXXX E70-N3108XX----XQ,UXXXXX E70-24MCC-FW0102XX115/177-X-Q,U,VXXXXX E70-24MCWH-FR3470X-X135/185X--L,O,P,Q,R,U,YXXXX- E70-24MCWH-FW3474X-X135/185-X-L,O,P,Q,R,U,YXXXX- E70-24MCWH-FN0059X-X135/185--XQ,UXXXX- E90-24MCC-FW3166-XX15/30/75/95-X-Q,U,VXXXX- E90-24MCC-FR3165-XX15/30/75/95X--Q,U,VXXXX- E90-24MCC-FN3185-XX15/30/75/95--XQ,U,VXXXX- E90-W 7869XX---X-Q,U,VXXXXX E90-R7867XX--X--Q,U,VXXXXX E90-N3109XX----XQ,U,VXXXXX E90-24MCCH-FW3471-XX115/177-X-Q,U,VXXXX- E90-24MCCH-FR3481-XX115/177X--Q,U,VXXXX- E90-24MCCH-FN0062-XX115/177--XQ,U,VXXXX- Specifcations and Ordering Information Also comes in NW (no writting). Models available with no writting, may be subject to minimum quantity order. Architects and Engineers Specifcations S1610 E70/E90 06/11 The speaker appliances shall be Wheelock Series E Speakers and the speaker strobe appliances shall be Wheelock Series E Speaker Strobes or approved equals. The speakers shall be UL Listed under Standard 1480 for Fire Protective Service and speakers equipped with strobes shall be listed under UL Standard 1971 for Emergency Devices for the Hearing-Impaired. In addition, the strobes shall be certifed to meet the requirements of FCC Part 15, Class B. All speakers shall be designed for a feld selectable input of either 25 or 70 VRMS, with selectable power taps from 1/8 watt to 2 watts. All models shall have listed sound output of up to 87 dB at 10 feet and a listed frequency response of 400 to 4000 Hz. The speaker shall also incorporate a sealed back construction. All inputs shall employ terminals that accept #12 to #18 AWG wire sizes. The strobe portion of the appliance shall produce a fash rate of one (1) fash per second over the Regulated Voltage Range and shall incorporate a Xenon fashtube enclosed in a rugged Lexan® lens. The strobe shall be of low current design. Where Multi-Candela Speaker Strobes are specifed, the strobe intensity shall have feld selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specifed when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the strobe portion of the appliance shall be compatible with Wheelock DSM sync modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized fash rate. The speaker and speaker strobe appliances shall be designed for indoor surface or fush mounting. The speaker and speaker strobe shall incorporate a speaker mounting plate with a grille cover which is secured with two screws for a level, aesthetic fnish and shall mount to standard electrical hardware requiring no additional trimplate or adapter. The fnish of the Series E speakers and strobe speakers shall be white, red, or nickel plate. All speaker and speaker strobe appliances shall be backward compatible. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY NotifcationCooper Notifcation is NJ Location 273 Branchport Ave. Long Branch, NJ 07740 P: 800-631-2148 F: 732-222-8707 www.coopernotification.com The Wheelock patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 1575 or the Wheelock Patented MCW multi-candela strobe with feld selectable candela settings of 15/30/75/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models include the patented MCC multi-candela ceiling strobe with feld selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the feld of view. Wheelock’s synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72. The Wheelock Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4” square, 100mm European backboxes or the SHBB surface backbox. If the fush backbox has side or top space between it and the fnished wall, the NATP (Notifcation Appliance Trimplate) may be used. It provides an additional .65” of trim for the Appliance. An attractive cover plate is provided for a clean, fnished appearance on all models. The Series RSSP Multi-Candela Strobe Plates are a cost effective way to retroft required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4” backboxes or for surface mount use with the Wheelock SBL2 surface backbox. Features • Approvals include: UL Standard 1971, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) See approvals by model in Specifcations and Ordering Information • ADA/NFPA/UFC/ANSI compliant. Meets OSHA 29 Part 1910.165 • Wall mount Multi-Candela models are available with Field Selectable Candela Settings of 15/30/ 75/110cd or 135/185cd. Single Candela models are available in 1575cd • Ceiling mount Multi-Candela models are available with feld selectable candela settings of 15/30/75/95cd or 115/177cd. (Square) • Strobes produce 1 fash per second over the regulated voltage range • 12 and 24 VDC models with wide UL “Regulated Voltage” us- ing fltered (DC) or unfltered VRMS input voltage • Synchronize using the Wheelock sync modules or panels with built-in Wheelock Patented Sync Protocol • Fast installation with IN/OUT screw terminals using #12 to #18 AWG wire Series RSS Series RSSWP Description For Weatherproof Series RSS See Datatsheet S9004 Series RSS and RSSP Strobes and Strobe Plates THE CITY OF NEW YORK DEPARTMENT OF BUILDINGS UL® 151-92-ES5391 7125-0785:141 7300-0785:154 Series RSS Notifcation F A C P DSM #3 Strobe NAC Cir. DSM #2 DSM #1 Strobe NAC Cir. Strobe NAC Cir. Sync Sync Sync + -+ +- - DSM Interconnecting wiring shown. Maximum of twenty (20) RSSRSS RSSRSS RSSRSS +- +- +- FROM PRECEDING APPLIANCE, SYNC MODULE, POWER SUPPLY OR FACP TO NEXT APPLIANCE OR EOLR Wiring Diagrams # SERIES RSS/RSSP APPLIANCE SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS “A” NAC CIRCUIT SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES Table 2: Audibles/Speakers for RSSP Strobe Plate ProductSeries Multitone AppliancesAMT, MT HornsAH, NH, HS Motor BellsMB-G6/G10 SpeakersET-1010/1080, E70, ET70 ChimesCH70 Table 1: Average RMS Current* RSS/RSSP 24VDC Models RSS/RSSP - Wall Mount Ceiling Mount 241575W24MCW24MCWH24MCC24MCCH 1575cd15cd30cd75cd110cd135cd185cd15cd30cd75cd95cd115cd177cd UL max*0.0900.0600.0920.1650.2200.3000.4200.0650.1050.1890.2490.3000.420 RSS/RSSP 24VDC Models RSS/RSSP Wall Mount 121575W 12 vdc0.152 UL max*0.255 * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfltered FWR ratings, see installation instructions. DSM + OUT 2 +OUT 1 + IN 1 + IN 2 MINUS 1 MINUS 2 + - - + SYNC AUDIBLE STROBE NAC CIRCUIT OUT STROBE NAC CIRCUIT RETURN FACP RSSRSSRSS RSSRSSRSS NOTE: All CAUTIONS and WARNINGS are identifed by the symbol . All warnings are printed in bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to fash at 1 fash per second minimum over their “Regulated Voltage Range”. Note that NFPA-72 specifes a fash rate of 1 to 2 fashes per second and ADA Guidelines specify a fash rate of 1 to 3 fashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • “Regulated Voltage Range” is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology “Listed Voltage Range”. TO NEXT APPLIANCE OR EOLR FROM PRECEDING APPLIANCE OR FACP TO NEXT STROBE OR EOLR FROM PRECEDING STROBE, SYNC MODULE, POWER SUPPLY OR FACP APPLIANCESTROBE +-+ + - - -++ + - - Series PS Power Supplies Series PS Power Supplies EOLR F A C P OUTPUTS 1-4 4-CLASS "B" OR 2-CLASS "A" HS HS HS RSS RSS RSS TO NEXT APPLIANCE OR EOLR FROM PRECEDING APPLIANCE, SYNC MODULE, POWER SUPPLY OR FACP+- STROBEAUDIBLE +- +--+ # For detail using DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83177 for DSM. For wiring information on the power supplies refer to Wheelock Power Supplies. SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH WHEELOCK POWER SUPPLIES STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE IN UNISON STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY All models sync with Wheelock DSM or Wheelock Power Supplies. # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. **For Weatherproof Series RSS Strobe specifcations see data sheet S9004. ***Refer to data sheet S7000 for mounting options. **** “A” stands for Agent Lettering. Model Order Code Wall Mount Ceiling Mount Non- Sync Strobe Candela 24 VDC 12 VDC Color RED Color WHITE Mounting Options*** Square or Round Agency Approvals ULMEACSFMFMBFP RSS-24MCW-FR940X-X15/30/75/110X-X-B,D,E,F,G,H,J,N,O,R,XSquareXXXXX RSS-24MCW-FW9401X-X15/30/75/110X--XB,D,E,F,G,H,J,N,O,R,XSquareXXXXX RSS-24MCW-AR****9773X-X15/30/75/110X--XB,D,E,F,G,H,J,N,O,R,XSquareXXXXX RSS-241575W-FR7471X-X15 (75 on Axis)X-X-B,D,E,F,G,H,J,N,O,R,XSquareXXXXX RSS-241575W-FW7788X-X15 (75 on Axis)X--XB,D,E,F,G,H,J,N,O,R,XSquareXXXXX RSS-121575W-FR7476X-X15 (75 on Axis)-XX-B,D,E,F,G,H,J,N,O,R,XSquareXXXXX RSS-121575W-FW7468X-X15 (75 on Axis)-X-XB,D,E,F,G,H,J,N,O,R,XSquareXXXXX RSS-24MCC-FW3158-XX15/30/75/95X--XB,D,E,F,G,H,J,N,O,R,XSquareXXXX- RSS-24MCC-FR3157-XX15/30/75/95X-X-B,D,E,F,G,H,J,N,O,R,XSquareXXXX- RSS-24MCCH-FW3461-XX115/177X--XB,D,E,F,G,H,J,N,O,R,XSquareXXXX- RSS-24MCWH-FR3465X X135/185XXB,D,E,F,G,H,J,N,O,R,XSquareXXXX- RSS-24MCWH-FW3464X X135/185XXB,D,E,F,G,H,J,N,O,R,XSquareXXXX- RSSWP-2475W-FR**9013X-X 180@ 77°F 75@ -31°F X-X-B,D,E,F,G,H,J,N,O,R,XSquareXXXX- RSSWP-2475W-FW**3034X-X 180@ 77°F 75@ -31°F X--XB,D,E,F,G,H,J,N,O,R,XSquareXXXX- RSSP-121575W-FR7798X-X15 (75 on Axis)-XX-D,E,ZSquareX-XXX RSSP-24MCW-FR9402X-X15/30/75/110X-X-D,E,ZSquareXXXXX RSSP-241575W-FR7793X-X15 (75 on Axis)--X-D,E,ZSquareXXXXX RSSP-24MCWH-FR9482XX135/185XXB,D,E,F,G,H,J,N,O,R,XSquareXXX-- Specifcations and Ordering Information Architects and Engineers Specifcations The visual notifcation appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a fash rate of one (1) fash per second over the Regulated Voltage Range and shall incorporate a Xenon fashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi-Candela appliances are specifed, the strobe intensity shall have feld selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specifed when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock’s DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized fash rate. The strobes shall be designed for indoor surface of fush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single- gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notifcation Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi-Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for fush mounting, or the Wheelock SBL2 backbox for surface mounting. All notifcation appliances shall be backward compatible. NOTE: Due to continuous development of our products, specifcations and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. S0410 RSS/RSSP 07/11 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY NotifcationCooper Notifcation is NJ Location 273 Branchport Ave. Long Branch, NJ 07740 P: 800-631-2148 F: 732-222-8707 www.coopernotification.com