Loading...
HomeMy WebLinkAboutB12-0391NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL T/MES ,. 1T}IV�1(�VA[L . Town of Vaii, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B12-0391 Project #: PRJ12-0484 Job Address: 4640 MEADOW DR VAIL Applied.....: 08/27/2012 Location......: VAIL RACQUET CLUB BUILDING 10 UNIT 2 Issued. ..: 09/12/2012 Parcel No....: 210112405002 OWNER ALFERS, STEPHEN D. & J. ALIS 08/27/2012 1918 BRYCE CT EVERGREEN,CO 80439 APPLICANT MIKE WARMENHOVEN CONSTRUCTIO 08/27/2012 Phone: 970-390-0411 MIKE WARMENHOVEN PO BOX 5923 VAI L CO 81658 License: C000003546 CONTRACTOR MIKE WARMENHOVEN CONSTRUCTIO 08/27/2012 MIKE WARMENHOVEN PO BOX 5923 VAI L CO 81658 License: C000003546 Phone: 970-390-0411 Description: INTERIOR REMODEL, NEW LIGHTING LAYOUT, NEW MECHANICAL EQUIPMENT. Occupancy: Type Construction: .......» ............................,............,............,.._.......,.......,. FEE SUMMARY ...__ Building Permit -----------> $839.75 Bldg Plan Check ----------> $545.84 Electrical Permit --------> $115.00 Elec Plan Check -----------> $74.75 Mechanical Permit ------> $280.00 Mech Plan Check ---------> $70.00 Plumbing Permit --------> $210.00 Plmb Plan Check ---------> $52.50 Valuation: $77,877.00 Use Tax Fee-----------------------> $1,357.54 Restuarant Plan Review--------> $0.00 Additional Fees--------------------> $0.00 Recreation Fee-------------------> $0.00 Investigation-------------------> $0.00 Will Call---------------------------> $20.00 TOTAL PERMIT FEES--------------> $3,565.38 Payments-----------------------------> 33,565.38 BALANCE DUE---------------------> $0.00 ..« ...........................................�.......,...........««.......................,.............,..............................................................«......«.....«.. DECLARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM. combination permit_012811 ��' � � ,� 1r�lYr�1�1(�kY�1`Y.YrirM'k'k'Rf. %f`Y�f`Y(M1(1('k'klrir'4+t4%'R+tff*44##ir�iYf`trtftfr141`41rRx/rd##4R4tkfrt4l�*'4R'k'4'k'A'kfMiFiF4'ktkf %�kYeYtMf'k'k*Yt'k'kw"k'kYtMdY'4f'4Yr�F*f f tk'4'4YtfrRYei4f�kfYfRiRiRiRRffr}rfriRiRf'1NlitihttrfVlrRRfRdAfMt`4f+liririt�f(**Yrt4Y'f 1MYrrtrtfYlf ffrtiR CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #:; 612-0391 Address: 4640 MEADOW DR VAIL Owner: ALFERS, STEPHEN D. & J. ALISON Location: VAIL RACQUET CLUB BUILDING 10 UNIT 2 ,...,..� ..............................................................,.,,..,.,.....,..,..,.,,......,,,......,.,...,............,......<...,......,............,......................, combination permit_012811 i f 1 U 1� V3 /lilL , .,****.*************.***«,,,,****..,.***«**«*««««*****...****,.**,.,.««„««*****«*.***.*.*...««*««******..*..*******.*,►..****«***.,********.�**********«****** REQUIRED INSPECTIONS AND STATUSES Permit#: B12-0391 Address: 4640 MEADOW DR VAIL Owner: ALFERS, STEPHEN D. & J. ALISON Location: VAIL RACQUET CLUB BUILDING 10 UNIT 2 ,.*****************«*******�.,*„«««*«�************«********«*.******,...,,.,►*******.********«*«,.,,***«***.*************«.****««««***«««***„**«****,,.*.***** Item: 00120 ELEC-Rough Item: 00200 MECH-Rough Item: 00220 PLMB-Rough/D.W.V. Item: 00230 PLMB-Rough/Water Item: 00240 PLMB-Gas Piping Item: 00310 MECH-Heating Item: 00030 BLDG-Framing Item: 00050 BLDG-Insulation Item: 00060 BLDG-Sheetrock Nail Item: 00190 ELEC-Final Item: 00290 PLMB-Final Item: 00390 MECH-Final Item: 00090 BLDG-Final combination permit_012811 **************+*********************************************************�***************�*** TOWN OF VAIL, COLORADO Statement ***************+*********+********+*****************************�*************************** Statement Number: R120001322 Amount: $3,020.10 09/12/201201:33 PM Payment Method: Check Init: LC Notation: #1173 / MIKE WARMENHOVEN CONSTRUCTION ----------------------------------------------------------------------------- Permit No: B12-0391 Type: COMBINATION BLDG PERMIT Parcel No: 2101-124-0500-2 Site Address: 4640 MEADOW DR VAIL Location: VAIL RACQUET CLUB BUILDING 10 UNIT 2 Total Fees: $3,565.38 This Payment: $3,020.10 Total ALL Pmts: $3,565.38 Balance: $0.00 ********************************�+***************************************************�****** ACCOUNT ITEM LIST: Account Code BP 00100003111100 EP 00100003111100 MP 00100003111100 PF 00100003112300 PP 00100003111100 UT 11000003106000 WC 00100003112800 Description BUILDING PERMIT FEES ELECTRICAL PERMIT FEES MECHANICAL PERMIT FEES PLAN CHECK FEES PLUMBING PERMIT FEES USE TAX 4°s WILL CALL INSPECTION FEE Current Pmts 839.7.5 115.00 280.00 197.81 210.00 1,357.54 20.00 ----------------------------------------------------------------------------- TOWN OF VA Project Street Address- Department of Community Development 75 South Frontage Road Vail, CID 81657 Tel: 970 - 479 -2128 www.vailgov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) } (Number) (Street) (Suite #) // Building /Complex Name: (/Q l tit U-b Contractor Information j ��/► ��° S Business Name: Business Address: l ­ j City l State: Zip: Contact Name: Contact Phone: Contact E- Mail: 1 1 I k� l,✓ r� v►�et,• 0 ✓ e-, I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review ap- proved, International Building and Residential Codes and other ordinance of the Town livable thereto. Owner /Owner's Representative Signature (Required) Applicant Information Applicant Name: ,A 11 5 &v,_ T Q 1'�-Q� S Applicant Phone: / ZO S 2-9 1`E5 � Applicant E -Mail: 47 4 am-, Project Information Owner Name: Parcel #: 0+'1 00.:a (For Parcel #, contact Eagle County Assessors Office at (970- 328 -8640 or visit www.eaglecounty.us/patie) For Office Use Only: Fee Paid: 4154S .A9 Received From: Cash Check # CC: Visa / MC Last 4 CC # exp date: Auth # R #: . ' Building Lot #: Block# Subdivision: U&)PLIA-[TC_p Work Class: New ( ) Addition ( ) Alteration ) I Type of Building: I Single - Family ( ) Duplex( ) Multi - Family (b( ) Commercial ( ) Other( ) Work Type: Interior Exterior ( \ ) Both( ) _ i Valuation of Work Included Plans Included Work Electrical ( )yes ( )No ( )Yes (X)No Mechanical &Yes ( )No ( )Yes( )No 15• o Z y Plumbing Yes ( )No ( )Yes ( )No �o Building )Yes ( )No ( )Yes ( )No Value of all work being performed: $ . (value based on IBC Section 109.3 & IRC Section 108.3) Electrical Square Footage / � 6 Z Detailed Scope and Location of Work: (use additional sheet if Date Received: ry) AUG 2'7 2012 V\VAJ TOWN OF VAIL State of Colorado Asbestos Testing & Abatement Requirements Asbestos testing and abatement protects workers, homeowners, neighbors and emergency services responders from ex- posure to harmful asbestos. It is your responsibility to be in compliance with the State. Please contact the State directly for their requirements at the contact info listed below. When is asbestos testing required? ANY building projects disturbing more than these threshold levels of building materials require asbestos testing: One- and Two - Family Dwellings: 32 square feet All Others (commercial spaces, hotel rooms, etc): 160 square feet Definition of a single - family dwelling: any dwelling unit that is used primarily for a single family, including multi - family /condominium units, and fractional fee units. Asbestos testing results must be provided with your application for a building permit. Tests which identify POSITIVE results at more than 1% require abatement by a State - certified abatement contractor. The clearance letter must be submitted to the Town of Vail before the building permit will be issued. Project Checklist My proj ct falls into the category checked below: Will not disturb more than the threshold limits identified above. Tested negative, or at 1% or below (1 copies of test results included) F] Tested positive at more than 1 %, requires abatement (1 copies of test results included) Tips & Facts: • Even recent construction projects may include asbestos - containing materials, so buildings of 4ny age require testing. • The "1989 Ban" on asbestos - containing materials is commonly misunderstood. "In fact, in 1991 the U.S. Fifth Circuit Court of Appeals vacated much of the so- called "Asbestos Ban and Phaseout" rule and remanded it to the EPA. Thus, much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce of many asbestos - containing product categories was set aside and did not take effect." - CDPHE Asbestos test results and abatement permit applications should be submitted to: Town of Vail, Community Development, 75 S Frontage Rd, Vail, CO, 81657. Town of Vail Contact: Fire Prevention Bureau Vail Fire Department 75 S Frontage Rd Fire—inspectors@vailgov.com 970 - 479 -2252 www.vailgov.com State of Colorado Contact: Colorado Department of Public Health and Environment Asbestos Compliance Assistance Group 303 - 692 -3158 asbestos@state.co.us www.cdphe.state.co.us 01- Jan -11 CBEnvirornmental, LLC 303 257 -8994 (Office) 303 235-0124 (Fax) July 18, 2012 Mike Warmenhoven P.O. Box 5923 Vail, CO 81658 Subject: Industrial Hygiene Support Services Dear Mr. Warmenhoven: CB Environmental, LLC (CBE) was retained by Mr. Warmenhoven to sample a building that is planned for renovation activities located at 4695 Racquet Club Drive, Building 10 -Unit 2 in Vail, Colorado. The asbestos survey included bulk sampling of suspect asbestos- containing material (ACM) observed on the ceiling and wall surfacing and submittal of samples for asbestos content laboratory analysis. The purpose of this inspection was to sample suspect ACM that would be disturbed by the renovation activities and to have laboratory analysis identify whether the suspect material(s) contained asbestos. If asbestos - containing, the materials) would then be removed properly by a General Abatement Contractor (GAC). Information researched by CBE indicated that the building was constructed in 1975. Asbestos - containing building materials are more likely to be present in buildings constructed prior to 1979; therefore, the subject building has a higher probability to contain ACMs. ACM is defined, by regulation, to be materials that contain greater than I% asbestos. Observations and Suspect Asbestos - Containing Materials at the Site The limited scope survey was conducted on July 17, 2012, by Colorado Department of Public Health and Environment (CDPHE) and Asbestos Hazard Emergency Response Act (AHERA) certified inspector Ms. Michelle Lococo (Certification Number 19736). The building is planned for renovation activities. Some minor destructive sampling was conducted on the above referenced material locations planned to be disturbed. Two (2) suspect materials were sampled in six (6) locations. Samples were submitted to Aerobiology Laboratory Associates Incorporated (Aerobiology), laboratory on July 17, 2012, for Polarized Light Microscopy (PLM) analysis to identify asbestos content. The samples were requested on an immediate turnaround time for results. 355 S. Teller St, Suite 200 Lakewood, CO 80226 www.cbemvironmentalnet Mike Warmenhoven Asbestos Inspection 7/18/12 2 Laboratory results Laboratory results received on July 17, 2012, document that zero (0) samples submitted contained asbestos above the regulatory limit of 1 %. Please find attached the Aerobiology laboratory report of PLM results. Conclusions: CBE observed two (2) types of suspect ACM that would be disturbed during the planned project renovation. The ceiling and wall surfacing were sampled in six (6) locations at the building located at 4695 Racquet Club Drive, Building 10 -Unit 2 in Vail, Colorado. Based on the site observations and, bulk sample PLM laboratory analysis results collected by CBE, zero (0) samples contained asbestos above the regulatory limit of 1 %; therefore, removal of these areas will NOT require asbestos abatement. CBE recommends that when ACM is removed/abated, that only a licensed asbestos abatement contractor using personnel trained in the handling of ACM be allowed to conduct such activities using appropriate methods (HEPA- filtered vacuuming, wet cleaning methods, respiratory protection, protective clothing, personnel decontamination, negative -air enclosures, air monitoring, etc). Thank you for the opportunity to provide Mr. Warmenhoven industrial hygiene services. If you have any questions on this limited scope asbestos building inspection, please contact me at your earliest convenience. Respectfully Submitted, CBEnvironmental, LLC Mike Lococo Senior Project Manager Attachments Limitations: This report describes the data collected and observations made by CBE during the visual inspection and bulk sampling in the above referenced building. CBE represents that its services were performed within the limits prescribed by applicable regulations, within scope of work as approved by the EPA and in a manner consistent with the level of care and skill ordinarily exercised by other professional consultants under similar circumstances. CBE accepts no responsibility for data collected, the recommendations made or expressed to the client, and/or other commitments made by persons or firms other than CBE. No other representation is made to the client, expressed or implied, and no warranty or guarantee is included or intended. 855 S. TeIIer St, Suite 200 Lakewood, CO 80226 wwwxbenvu-onmeirtaL M w V O a�i C O o C a> y- 3 � N ORMW of Am*dm Ilmw cdrw AW su9e mr r.t..,.r. menur 3133! 3M vwwatfobkkerAd Cial NOW Cu FnNreuMnla DNl c (7171 9b,ad Ak. 355 4 TsW St Cc X11 W / DbRto, iiW (77.11 coy. tilau 2ii IA..r*OA COXCM D%U Amm, -Md (717.13 Ant Min Lom HYIAP1siCade MA6aU D1M R( ] (1140 FNI Nmul ULd Ww*mhu -n 405 Rw4uA CM Dr Vul El) PryaetlD dm ID 1tH[grl8o I2flum 1'.lIIII3134IR ik ID N TarRqumrd. "a A "m in m &npia mdwt Pds" Ai mhfiwm"y i Cipawus Ulms (FM k ('otlbd I:rON Dnhnrirdimul',WWrs w RA imWnc hliwillr, FFA- (QI:'R "91'114 hl5 IW. Smrpk Haiirka" M.wial Geryjwiln >< llrpe'Lr:cr ` m. i... 15N' lla:- ,l41rc91u Denid .."" Parw dw Nam -rile" Floc h 1 "Alan Psrn 111&k IAACMA 1.m rltr.9 1 ' 11(11 IafflLill9 IA Wtile Terse N r. IJD � ? 1'.lIIII3134IR UfletaTixum N V tiD lrlr 1_tUf16315611' 1Y11 le )eels CCKWjnl N 510 VD IUD c 1_r1L1833�ID Uft'f1nD -rNdl N me VD IS i5 0 .4191: I_'(C1838%2A While falurir u'WhicNil N Ire VD IUD C.G 1ZIL133ig2B t111itel "1n17y79d1 N We SID 15 55 G All 12U]8 -W3A Whit fakir( v W1ite Will N Nre YD lrm Co 120(13334"30 KhteT)nl}1>+dl N Iwo YD IS 5S Ci 13111 128. W4A Whole f4mlurr v`'M'Irle Poitl N t-q Yp lrx C 12f1u63tS1,+1B 11>tiiue"fmL}rwdl N 9?`. !Ib IS iS C1 Pam 1)13 Q rts a P - Pair C - C m" b Hndw U - D Dwwm hl ici r -U NIT - N3.1i1DSa Am 71 NAC • Noe•A d*sifrm .0 to Wy 00 �g � � U 4 - Mosis AC -14b; iM AN - ` CHr - k CL-C22rk IR wImldL laieeNry dyn 10, ull. Ckma rystpelvAW RD ■tae Dekaec 1.49:3310. ila&..Me 311h 736.lAi;max 302W,14& Q rts a P - Pair C - C m" b Hndw U - D Dwwm hl ici r -U NIT - N3.1i1DSa Am 71 NAC • Noe•A d*sifrm .0 to Wy 00 �g � � U It A dkm AA a4"6" y [attt4ROrey ASSOCNIES. IIYCX�'QtiAT[D .ati6am MAMA Ccaift-we a An713ih 13"9 Cobs, Aye sure s« -W ?3' 37.5 ffi cum Num CDb"Vi"Im"Ill f1nf.,, - -- Drl.cornwL :x17-112 911,00 Ostrom 115 S T.11" 1, cle 200 I 11a�Jl Dow F^ -dvW: :11 792 CW9. sum Z111, IAWI O9). Co ®275 Dow Aau42Mt :7I112 A.nr: Mitvl a N411AP ,ab i.J. iialti,q Dwc Cp•wW: :717.12 I:Mrri} P"� Homer MiAw- Wanwmlw.m 4M4 RaaNus CU Ih %al. Co IMy. -rl III: 121aRIR9 IY1<W.if4•i1j Wtv.1, Terttre xV7hrt Pam l�n ul. 11M. Its: F,E4-1 JIAI ASx -b ba Mammon V.ah.d Pdar w1 00,1 N11 --Iy D4wn.a9lrirrg('tdll, "Na11ea1 01111 the:Ylwwliwhter d,AAC4+ lb:.Ip„klar_\h&,wk f.Pi -rile R -9, IIG. 1.1, 1791 SjMk,IdRriCleulSn Ptnwr�l lle.Ylriar d XMVL I , Ca `3in Qnw.t�. h. Inu Paxtsrlrl� lehewu. Vkeft- +d W-1— ,- .tih�1e N.•rli- MM-1 Von, %UA—1 C.nr CI -I ah ti.0 i_ \vnhn uii? t`{HtiI1� +•'A WhicTaK N 1011, GI) lakwum An" r { - IY1<W.if4•i1j Wtv.1, Terttre xV7hrt Pam N 11M. itI? IM (' I?II(1�3iS1lC 11'hlh Juut:<lmpiursl N W0 UD 111) C 11^110 InIQL3194,A MawTt.Are A 14hrCImi, N 51. I.I) lU1 C I'_tx�.1f9 -L13 'AFu6eiar I h1 u rl l N +i ". R I? h B9 t. Q n Q • QW3: P• FHf1e C - CwhwA.� O - QyQrran Q:1),ar M- IJi u T -Tr VTR - Nw ,A.Ixwirum TR go �O � � q CYJ Irna'll.' + 111111;5- IC LtinJtl: _ 4.n hulini itc i �a� A\ > .� O 125 +�� fr /Y�'7►,— CI[lii lbn,.ut lc O Ck C'ta:ilulik t y C TR 7rrnr4nr w Twr:e-1.., TLw I`.• w d lakwum An" urwviw ND -Wan? 171twed 3 O ty 139 -•94. Cif Aw. Siiw Dal. Lalao+a4 I'D MAIL 011;.,223715 y NOV 2d9 Q n Q • QW3: P• FHf1e C - CwhwA.� O - QyQrran Q:1),ar M- IJi u T -Tr VTR - Nw ,A.Ixwirum TR go �O � � q CYJ Mike Warmenhoven Asbestos Inspection 7/18/12 ATTACHMENT B CERTIFICATIONS 7� 4 7 llilt, s ' ! t z �1! it i t :z a F, t 5 355 S. Teller St., Suite 200 Lakewood, CO 80226 www.cbenvironmental.net i Model Foal Oplim High Law MW. aftlenctr Vent System Approval & Requirements This fireplace is approved for the following vent systems: Nicdlet NG 12,500 4,500 79.70% Simpson Dora- Vent T. DV -GS Pipe - 5" x 8" LP 12,500 4 ,500 80.50% Selkirk Metalbestosw - 5" x 8" Amed -Verdw - 5" x 8" The Nicollet comes standard with an electronic ignition pilot system. The included Metal FabT - 5" x 8" thermostatic remote control will adjust the flame, fan speed & back lighting - fan kit IS ICCT - 5" x 8" an optional accessory. SecudtyT - 5" x 8" Features RLHTm - 5" x 8" Canada P -4 approved Electronic ignition pilot system - standing pilot option as well EIS: For each additional elbow used after the first 2 elbows, Ceramic litetime glass (21" X 14 ") quick4atch removal 3' must be subtracted from the maximum venting allowed. Remote control - (flame, light & fan adjustment) Note (2) 45' elbows =(I) 90' elbow. 2- receptacle assembly for wiring Black enamel firebox liner Horizontal Terminations Light kit bottom Minimum: 9(r elbow +termination cap Ma>enum: 20' Engineer -designed burner system A horimnW Vend heat shield, that is included with the fireplace, Minnesota Energy Code Compliant to 50 pascals must be installed when using a 90' elbow directly off top of fireplace. Required for Installation* IMPORTANT: Nozy Heat part #800- WProrM@ -WFr2, Rectangular or convex contemporary frameHace- Must be used on ALL horizontal vent runs. Measurements - 21 1/16 "w x 33 3/8 "h #800 -WPT Wii - 6W wall thickness) (black, rust, titanium or brushed stainless) #800 -WPF2 = 6th" - 1254" wall thickness Glass media kit (various colors available) Door faces offered for the model 'Iwo Harbors' can also be used Vertical Terminations Safety Minimum: 3' Maximum: 36' Each welt factory tested! Horizontal/ Vertical COMB_ O_: Tested by PFS Corp. 20' horizontal / 20' vertical` Complies with ANSI- 121.88a - 2009•CSA 2.33 -2009 P.4.1 -09 'Vented Gas Fireplace heaters' Please consult the venting chart in the installation manual. U.S. & Canadian installation approved Sealed combustion chamber Removable control board with safety pilot Automatic pressure relief glass system Bedroom & mobile home approved r1. TP FrW — Left 1 7" r �'4" 31Y{ ' 21 I 1458" 23J. 2 QUALITY FIREPLACES FOR LIFE tgy�" sue- -- Height 31I/r Width 1812" Back width 51/4" Depth 14 3B" Weight 761.. Fraleing Dimensions Height t 32 W Width 19 34" Depth 14 7l8" Clearances Fireplace face top to framing 1" Fireplace left & right sides & hack From decorative face lop (n order to remove face) 1/4" Fireplace bottom to flooring 0" Fueplace base toceiling 52" Fireplace side stand -offs to 0 adjacent sidewa0 Top of fireplace to 314" projection 21/4" Mantel must be a minimum of 7 W from top of fireplace fare. The maximum depth at this height is 12 ". See additional mantel cleararnce configurations in the installation manual. 9W 2Y' 0 rl4V" I• CONDENSING RESIDENTIAL GAS BOILERS LL55 1 HAN 20 ppM NUX DIRECT VENT FLEXIBILITY TO 100 FEET UP TO 98% EFFICIENCY IN LOW TEMP APPLICATIONS A o High EfficiencyyVater Heaters, Boilers and Pool Heaters UP T096% AFUE EFFICIENCY k nigh th eat i ngbo i I er.co m KNIGHrBOIL_R DIMENSIONS AND SPECIFICATIONS - FLOOR- STANDING MODELS Models: KBN 081.211 A nnwst�� FRONT WALL- -MOUNT MODELS 0 R Mx w.ET SM a,7 Models: WBNOS11-211 KBN286 57 285 %.0 260 226 t9-114 15 -i/4- RA 1D -3147 10 -3/4' 2- 63/4' NA 3 -1/4 4-1/ 2 -3/4 1R 1 2 130 29-1/4' 15-3/4 NA 10-31 1Q 314 31 51 NA 3 -114 4-14 2 -3/ 1 1 134 2:1 4203/ NA 15-3/4 81 3 -t 51 NA 8 3/4 9 3/ 11 1 1 3 33 -1 1 12l/ 111 fijl 1 1- 21 -i /4 23 13/ 1 NA 1 1, 157 33-1/4 22 -11 16.1 15-31 14-1111' SAW 21-114- 23 1 -3/ 16-11 NA iR 1 3 41 -114' 19 -3/4' 12 -314' 13-1R' 6' T 34' 31' 11 -314' 41/4' NA 3/4' 1 -1/4 4' r 224 Notes: Indoor installation only. All information subject to change. Change *N' to 'L' for LP gas models. SMART SYSTEM"° FEATURES > SMART SYSTEM Digital Operating Control Multi -Color Graphic LCD Display with Navigation Dial and Soft Keys Three Setpoint Temperature Inputs Built -in Cascading Sequencer for up to 8 Boilers Cascade Multiple Sized Boilers Lead Lag Efficiency Optimization Outdoor Reset Control with Outdoor Air Sensor Programmable for Three Reset Temperature Inputs Programmable System Efficiency Optimizers Night Setback w /Overide Function DHW Night Setback w /Overide Function Anti- Cycling Outdoor Air Reset Curve Ramp Delay Boost Temperature & Time Three Pump Control System Pump with Parameter for Continuous Operation Boiler Pump with Variable Speed Pump Control' Domestic Hot Water Pump Domestic Hot Water Prioritization DHW tank piped with priority in the boiler loop DHW tank piped as a zone in the system with the pumps controlled by the Smart System DHW Modulation Limiting Separately Adjustable SH /DHW Switching Times' Building Management System Integration 0 -10VDC Input to Control Modulation or Set Point 0 -10VDC Modulation Rate Output 0 -10VDC Input Signal from Variable Speed System Pump* 0.10VDC Input to Enable /Disable call for heat 'Exclusive feature, available only from Lachinvar > High - Voltage Terminal Strip > 120 VAC / 60 Hertz / 1 Phase Power Supply > Three Sets of Pump Contacts > Low Voltage Terminal Strip 24 VAC Device Relay Proving Switch Contacts now Switch Contacts Alarm on Any Failure Contacts > Runtime Contacts > DHW Thermostat Contacts 3 Space Heat Thermostat Contacts System Sensor Contacts DHW Tank Sensor Contacts > Outdoor Air Sensor Contacts > Cascade Contacts > 0 -10VDC BMS External Control Contact 0 -10VDC Boiler Rate Output Contacts 0 -10VDC Variable Speed System Pump Signal Input > 0 -10VDC Signal to Control Variable Speed Boiler Pump Modbus Contacts > rime Clock > Data Logging > Hours Running, Space Heating Hours Running, Domestic Hot Water Ignition Attempts > Last 10 Lockouts > Access to BIAS Settings through Graphic LCD Display > Maintenance Reminder > Custom Maintenance Reminder with Contractor Info > Installer Ability to De- activate Service Reminder > Low-Water Flow Safety Control & Indication > Dual Level Password Security > Customizable Freeze Protection Parameters STANDARD FEATURES > Energy Starr" Qualified > Up to %% DOE AFUE Efficiency > Modulating Burner with 5:1 Turndown > Direct -Spark Ignition Low -NOx Operation > Feld Convertible from Natural to LP Gas > ASME Stainless Steel Heat Exchanger > 30 psi ASME Relief Valve > Vertical & Horizontal Direct -Vent > PVC, CPVC, Polypropotene or SS Venting up to 100 feet > Factory Supplied Sidewall Vent Termination > Smart System Control > Condensate Trap > Other Features > Automatic Reset High Limit > Adjustable High Limit w /Manual Reset > Boiler Circulating Pump > Adjustable Leveling Legs (KB Models only) > Wall -Mount Bracket (WB Models only) > Zero Clearances to Combustible Materials > 12 -Year Limited Warranty (See Warranty for Details) OPTIONAL EQUIPMENT > Modbus Communication > Condensate Neutralization Kit > Multi Temperature Loop Control > Flow Switch > Low -Water Cutoff w /Manual Reset & Test > Alarm Bell > Concentric Vent Kit SMART SYSTEM PC Software > Stack Frame FIRING CODES > M9 Standard Construction > M7 California Code ru T w An R1 . l' • M E M B E R patent Pending f�\/ j-fll _ IIIeYElnriesrcwmrBatas .BaaenW Hd HeHen ou n.> rz os WBN106 21 105 95.4 94 82 W13Ni51 30 150 955 "1 119 WBN211 42 210 95.7 190 165 0081 16 80 953 72 63 KBN106 11 105 95.4 94 82 KBN151 30 150 953 135 119 KBN211 42 210 95.7 190 165 KBN286 57 285 %.0 260 226 t9-114 15 -i/4- RA 1D -3147 10 -3/4' 2- 63/4' NA 3 -1/4 4-1/ 2 -3/4 1R 1 2 130 29-1/4' 15-3/4 NA 10-31 1Q 314 31 51 NA 3 -114 4-14 2 -3/ 1 1 134 2:1 4203/ NA 15-3/4 81 3 -t 51 NA 8 3/4 9 3/ 11 1 1 3 33 -1 1 12l/ 111 fijl 1 1- 21 -i /4 23 13/ 1 NA 1 1, 157 33-1/4 22 -11 16.1 15-31 14-1111' SAW 21-114- 23 1 -3/ 16-11 NA iR 1 3 41 -114' 19 -3/4' 12 -314' 13-1R' 6' T 34' 31' 11 -314' 41/4' NA 3/4' 1 -1/4 4' r 224 Notes: Indoor installation only. All information subject to change. Change *N' to 'L' for LP gas models. SMART SYSTEM"° FEATURES > SMART SYSTEM Digital Operating Control Multi -Color Graphic LCD Display with Navigation Dial and Soft Keys Three Setpoint Temperature Inputs Built -in Cascading Sequencer for up to 8 Boilers Cascade Multiple Sized Boilers Lead Lag Efficiency Optimization Outdoor Reset Control with Outdoor Air Sensor Programmable for Three Reset Temperature Inputs Programmable System Efficiency Optimizers Night Setback w /Overide Function DHW Night Setback w /Overide Function Anti- Cycling Outdoor Air Reset Curve Ramp Delay Boost Temperature & Time Three Pump Control System Pump with Parameter for Continuous Operation Boiler Pump with Variable Speed Pump Control' Domestic Hot Water Pump Domestic Hot Water Prioritization DHW tank piped with priority in the boiler loop DHW tank piped as a zone in the system with the pumps controlled by the Smart System DHW Modulation Limiting Separately Adjustable SH /DHW Switching Times' Building Management System Integration 0 -10VDC Input to Control Modulation or Set Point 0 -10VDC Modulation Rate Output 0 -10VDC Input Signal from Variable Speed System Pump* 0.10VDC Input to Enable /Disable call for heat 'Exclusive feature, available only from Lachinvar > High - Voltage Terminal Strip > 120 VAC / 60 Hertz / 1 Phase Power Supply > Three Sets of Pump Contacts > Low Voltage Terminal Strip 24 VAC Device Relay Proving Switch Contacts now Switch Contacts Alarm on Any Failure Contacts > Runtime Contacts > DHW Thermostat Contacts 3 Space Heat Thermostat Contacts System Sensor Contacts DHW Tank Sensor Contacts > Outdoor Air Sensor Contacts > Cascade Contacts > 0 -10VDC BMS External Control Contact 0 -10VDC Boiler Rate Output Contacts 0 -10VDC Variable Speed System Pump Signal Input > 0 -10VDC Signal to Control Variable Speed Boiler Pump Modbus Contacts > rime Clock > Data Logging > Hours Running, Space Heating Hours Running, Domestic Hot Water Ignition Attempts > Last 10 Lockouts > Access to BIAS Settings through Graphic LCD Display > Maintenance Reminder > Custom Maintenance Reminder with Contractor Info > Installer Ability to De- activate Service Reminder > Low-Water Flow Safety Control & Indication > Dual Level Password Security > Customizable Freeze Protection Parameters STANDARD FEATURES > Energy Starr" Qualified > Up to %% DOE AFUE Efficiency > Modulating Burner with 5:1 Turndown > Direct -Spark Ignition Low -NOx Operation > Feld Convertible from Natural to LP Gas > ASME Stainless Steel Heat Exchanger > 30 psi ASME Relief Valve > Vertical & Horizontal Direct -Vent > PVC, CPVC, Polypropotene or SS Venting up to 100 feet > Factory Supplied Sidewall Vent Termination > Smart System Control > Condensate Trap > Other Features > Automatic Reset High Limit > Adjustable High Limit w /Manual Reset > Boiler Circulating Pump > Adjustable Leveling Legs (KB Models only) > Wall -Mount Bracket (WB Models only) > Zero Clearances to Combustible Materials > 12 -Year Limited Warranty (See Warranty for Details) OPTIONAL EQUIPMENT > Modbus Communication > Condensate Neutralization Kit > Multi Temperature Loop Control > Flow Switch > Low -Water Cutoff w /Manual Reset & Test > Alarm Bell > Concentric Vent Kit SMART SYSTEM PC Software > Stack Frame FIRING CODES > M9 Standard Construction > M7 California Code ru T w An R1 . l' • M E M B E R patent Pending f�\/ j-fll _ IIIeYElnriesrcwmrBatas .BaaenW Hd HeHen irect Water Heaters sS' n 6(�' �kAt Model Storage Volume Gals. Coil Heating Surface . Ft Dimensions (inches) Ht Dia. Piping Connections - N.P.T. Domestic Boiler Water Water INOut In/Out Max. Working Pressure (psi) Approx Shipping Wt -Lbs. 30 30 7.0 34.0 23.5 3/4 1 150 85 40 40 7.5 44.0 23.5 3/4 1 150 100 40L 42 7.1 36.0 28.0 3/4 1 150 100 50 50 8.0 54.0 23.5 3/4 1 150 110 60 60 8.3 62.0 23.5 3/4 1 150 125 60L 60 7.5 46.0 28.0 3/4 1 150 120 80 80 8.0 56.0 28.0 1 1 150 140 115 115 8.9 74.0 28.0 1 1 150 175 HighOutp ut Units 80 -HO and 115-HO 80 -HO 1 80 1 13.4 1 56.0 28.0 1 1 1 150 155 115 -HO 115 1 14.4 74.0 28.0 1 1 150 190 80 -HO -C 80 1 13.4 56.0 28.0 21.0 1 1/4 150 155 11 -1-10-C 115 1 14.4 74.0 28.0 1 11/2 11/4 150 190 HOT OUTLET &0 BOILER RETURN T.PVALVE Bn O DON. COLD INLET BORER SUPPLY O O STANDARD U WS 3/4' NPT BB RECIRC PORT T.PgLL11E 11/2' NPT HOT OUTLET I 1 1/4� NPT - 1 114' NPT 809-ER SUPPLY BOLER RETURN 112' NPT LOA COLD INLET C UNITS Model Max. First Hour Rating Gal. /Hr. @ Continuous Rating Gal./Hr. @ Boiler Output Required Min. Boiler Water Flow Through Coil Pressure Drop Through Coil 140 F 115 F 140 F 115 F BTU/Hr. Gal. /Min. FtWater 30 195 259 168 232 125,600 14.0 5.3 40 215 284 179 248 134,200 14.0 5.7 40L 195 259 168 232 1 125,600 14.0 5.3 50 234 308 189 263 129,900 14.0 6.0 60 254 333 200 279 151,000 14.0 6.2 60L 233 302 179 248 134,100 14.0 5.7 80 266 341 194 269 145,600 14.0 6.0 115 319 403 216 300 162,400 14.0 6.6 High Output Units 80 -HO and 115-HO 80 -HO 386 507 314 435 235,600 14.0 9.9 115 -HO 439 568 336 465 251,700 14.0 10.5 80 -HO -C 408 537 336 465 251,700 21.0 15.8 115 -HO -C 450 583 347 480 259,800 21.0 16.7 Note: All Ratings are based on 200 degree F boiler water supply and 50 degree F cold Water inlet. For 180 degree F boiler water supply multiply by ratings by 0.86 In the interest of continuous improvement, specifications are subject to change without notice. WWW.hoat- flo.com �� i _ Heat -Flo HEATING PRODUCTS f BRUSH CREEK E L E C T R I C, I N C. Proposal To Mike Warmenhoven From : George S. Henry Date : 19 July, 2012 Re Electrical Estimate for Alfers Residence, Building 10, Unit 2, Vail Racquet Club The price for Alfers remodel is This project includes 450 square feet,' r The price does not include any demolition. All required framing is by others. Included in the estimate are the following: 1. Remove existing panel and replace with 20- circuit main lug only interior panel and new breakers. :_I_ LI � n a. Five (5) overhead lights b. One (1) switch 3. Water Closet • Page 1 Brush Creek Eectric. Inc. Warmenhoven: A Jars Residence Page 2 of3 a. Two (2) overhead lights b. One (1) shower light c. Two (2) switches 4. Vanity a. Remove existing light b. Add two (2) sconces c. Add one (1) GFCI receptacle d. Relocate one (1) switch e. Install 39 square feet of floor heat and thermostat 5. Kitchen a. Install four (4) downlights b. Install two (2) single -pole switches c. Cooktop: wire for second small appliance circuit d. Microwave: install wiring e. Dishwasher: install wiring f. Install 16" unde abinet light g. Install 35 square feet of floor heat and one thermostat 6. Living Room a. Install three (3) downlights b. Install two (2) wall washers c. Fish receptacle for wall - mounted television d. Fish CATV feed for wall- mounted television 7. Boiler Room a. Wire boiler b. Wire new side arm • Page 2 Brush Creek Electric, Inc. Warmenhoven: Alfers Residence Page 3 of 3 8. Replace all existing receptacles and switches with new Decors devices Thank you for the opportunity to bid on this project! • Page 3 Alfer Residence Load Calculation Building 10, Unit 2, Vail Racquet Club 525 sq ft X 3 VA 1575 First 10,000 VA at 100% 10000 Small Appliance x 2 3000 Next 12,925 VA at 40% 5160 Laundry 0 total 15160 Range 12000 Disposal 1200 AMPS (15160/208) 72.9 Dish Washer 1600 Refrigerator 1000 Microwave / Hood 1550 Unde Tile Heat 1000 Total 22925 VA The unit is heated by a gas boiler; DHW Heat is by a boiler side arm; There is not a laundry room. All Pro 1499 ICT All Pro 1493 Trim Sylvania 37wMR16 IR Tenent Fibre Fire Hat Lighting Efficacy 19 LED Undercabinet Lighting 0.13 watt lamps x 26 GEORGE S. HENRY Owner BRUSH CREEK E L E C T Q I C. I N C. CO. Box 125 • 1: iglr. Colorado 81631 -0125 Telephone: (970) 328 -2254 Fax: (970) 328 -2440 Cell: (970) 390 -6327 E -Mail: george @brushcreekelectric.con, / I i>547_ W a 12 -11 -2012 Inspection Request Reporting ( Page 9 4:0312m Vail. CO - City Of W"Tiz-c49 -I Requested Inspect Date: Wednesday, December 12, 2012 Site Address: 4640 MEADOW DR VAIL VAIL RACQUET CLUB BUILDING 10 UNIT 2 A/P /D Information Activity: B12 -0391 Type: COMBO Sub Type: AMF Status: ISSUED Const Type: Occupanc : Use: Insp Area: Owner: ALFERS, STEPHEN D. & J. ALION Contractor: MIKE WARMENHOVEN CONSTRUCTION Phone: 970 - 390 -0411 SERVICES Description: INTERIOR REMODEL, NEW LIGHTING LAYOUT, NEW MECHANICAL EQUIPMENT. Requested Inspection(s Item: Requestor: Comments: Assigned To: Action: Item: Requestor: Comments: Assigned To: Action: CONSTRUCTION Time Exp: CONSTRUCTION Time Exp: Item: 390 MECH -Final Item: Requestor: MIKE WARMENHOVEN CONSTRUCTION 200 MECH -Rough h 09/26/12- Inspector: Comment: SERVICES Item: Comments: Assigned To: 390 -0411 SGR Action: sgremmer Time Exp: 230 PLMB- Rough/Water 09/26/12 Inspector: Comment: ** Approved ** sgremmer Item: Inspection History Item: 120 ELEC -Rough 09/17/12 Inspector: Comment: ** Approved ** mdenney Item: 200 MECH -Rough h 09/26/12- Inspector: Comment: ** Approved ** sgremmer Item: 220 PLMB - Rough /D.W.V. ** Approved ** 09/26/12 Inspector: Comment: sgremmer Item: 230 PLMB- Rough/Water 09/26/12 Inspector: Comment: ** Approved ** sgremmer Item: 240 PLMB -Gas Piping 09/26/12 Inspector: Comment: ** Approved ** sgremmer Item: 310 MECH - Heating 09/26/12 Inspector: Comment: ** Approved ** sgremmer Item: 30 BLDG - Framing REPT131 Requested Time: 01:00 PM Phone: 970 - 390 -0411 Entered By: JMONDRAGON K Requested Time: 10:30 AM Phone: 970 - 390 -0411 Entered By: JMONDRAGON K Requested Time: 11:00 AM Phone: 970 - 390 -0411 Entered By: JMONDRAGON K Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Run Id: 14623