HomeMy WebLinkAboutB12-0391NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL T/MES
,.
1T}IV�1(�VA[L .
Town of Vaii, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
COMBINATION BLDG PERMIT Permit #: B12-0391
Project #: PRJ12-0484
Job Address: 4640 MEADOW DR VAIL Applied.....: 08/27/2012
Location......: VAIL RACQUET CLUB BUILDING 10 UNIT 2 Issued. ..: 09/12/2012
Parcel No....: 210112405002
OWNER ALFERS, STEPHEN D. & J. ALIS 08/27/2012
1918 BRYCE CT
EVERGREEN,CO
80439
APPLICANT MIKE WARMENHOVEN CONSTRUCTIO 08/27/2012 Phone: 970-390-0411
MIKE WARMENHOVEN
PO BOX 5923
VAI L
CO 81658
License: C000003546
CONTRACTOR MIKE WARMENHOVEN CONSTRUCTIO 08/27/2012
MIKE WARMENHOVEN
PO BOX 5923
VAI L
CO 81658
License: C000003546
Phone: 970-390-0411
Description:
INTERIOR REMODEL, NEW LIGHTING LAYOUT, NEW MECHANICAL
EQUIPMENT.
Occupancy: Type Construction:
.......» ............................,............,............,.._.......,.......,. FEE SUMMARY ...__
Building Permit -----------> $839.75 Bldg Plan Check ----------> $545.84
Electrical Permit --------> $115.00 Elec Plan Check -----------> $74.75
Mechanical Permit ------> $280.00 Mech Plan Check ---------> $70.00
Plumbing Permit --------> $210.00 Plmb Plan Check ---------> $52.50
Valuation: $77,877.00
Use Tax Fee-----------------------> $1,357.54
Restuarant Plan Review--------> $0.00
Additional Fees--------------------> $0.00
Recreation Fee-------------------> $0.00
Investigation-------------------> $0.00
Will Call---------------------------> $20.00
TOTAL PERMIT FEES--------------> $3,565.38
Payments-----------------------------> 33,565.38
BALANCE DUE---------------------> $0.00
..« ...........................................�.......,...........««.......................,.............,..............................................................«......«.....«..
DECLARATIONS
I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and
other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149
OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM.
combination permit_012811
��'
� � ,�
1r�lYr�1�1(�kY�1`Y.YrirM'k'k'Rf. %f`Y�f`Y(M1(1('k'klrir'4+t4%'R+tff*44##ir�iYf`trtftfr141`41rRx/rd##4R4tkfrt4l�*'4R'k'4'k'A'kfMiFiF4'ktkf %�kYeYtMf'k'k*Yt'k'kw"k'kYtMdY'4f'4Yr�F*f f tk'4'4YtfrRYei4f�kfYfRiRiRiRRffr}rfriRiRf'1NlitihttrfVlrRRfRdAfMt`4f+liririt�f(**Yrt4Y'f 1MYrrtrtfYlf ffrtiR
CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF
Permit #:; 612-0391 Address: 4640 MEADOW DR VAIL
Owner: ALFERS, STEPHEN D. & J. ALISON Location:
VAIL RACQUET CLUB BUILDING 10 UNIT 2
,...,..� ..............................................................,.,,..,.,.....,..,..,.,,......,,,......,.,...,............,......<...,......,............,......................,
combination permit_012811
i
f
1 U 1� V3 /lilL ,
.,****.*************.***«,,,,****..,.***«**«*««««*****...****,.**,.,.««„««*****«*.***.*.*...««*««******..*..*******.*,►..****«***.,********.�**********«******
REQUIRED INSPECTIONS AND STATUSES
Permit#: B12-0391 Address: 4640 MEADOW DR VAIL
Owner: ALFERS, STEPHEN D. & J. ALISON Location:
VAIL RACQUET CLUB BUILDING 10 UNIT 2
,.*****************«*******�.,*„«««*«�************«********«*.******,...,,.,►*******.********«*«,.,,***«***.*************«.****««««***«««***„**«****,,.*.*****
Item: 00120 ELEC-Rough
Item: 00200 MECH-Rough
Item: 00220 PLMB-Rough/D.W.V.
Item: 00230 PLMB-Rough/Water
Item: 00240 PLMB-Gas Piping
Item: 00310 MECH-Heating
Item: 00030 BLDG-Framing
Item: 00050 BLDG-Insulation
Item: 00060 BLDG-Sheetrock Nail
Item: 00190 ELEC-Final
Item: 00290 PLMB-Final
Item: 00390 MECH-Final
Item: 00090 BLDG-Final
combination permit_012811
**************+*********************************************************�***************�***
TOWN OF VAIL, COLORADO Statement
***************+*********+********+*****************************�***************************
Statement Number: R120001322 Amount: $3,020.10 09/12/201201:33 PM
Payment Method: Check Init: LC
Notation: #1173 / MIKE
WARMENHOVEN CONSTRUCTION
-----------------------------------------------------------------------------
Permit No: B12-0391 Type: COMBINATION BLDG PERMIT
Parcel No: 2101-124-0500-2
Site Address: 4640 MEADOW DR VAIL
Location: VAIL RACQUET CLUB BUILDING 10 UNIT 2
Total Fees: $3,565.38
This Payment: $3,020.10 Total ALL Pmts: $3,565.38
Balance: $0.00
********************************�+***************************************************�******
ACCOUNT ITEM LIST:
Account Code
BP 00100003111100
EP 00100003111100
MP 00100003111100
PF 00100003112300
PP 00100003111100
UT 11000003106000
WC 00100003112800
Description
BUILDING PERMIT FEES
ELECTRICAL PERMIT FEES
MECHANICAL PERMIT FEES
PLAN CHECK FEES
PLUMBING PERMIT FEES
USE TAX 4°s
WILL CALL INSPECTION FEE
Current Pmts
839.7.5
115.00
280.00
197.81
210.00
1,357.54
20.00
-----------------------------------------------------------------------------
TOWN OF VA
Project Street Address-
Department of Community Development
75 South Frontage Road
Vail, CID 81657
Tel: 970 - 479 -2128
www.vailgov.com
Development Review Coordinator
BUILDING PERMIT APPLICATION
(Separate applications are required for alarm & sprinkler)
} (Number) (Street) (Suite #) //
Building /Complex Name: (/Q l tit U-b
Contractor Information j ��/► ��° S
Business Name:
Business Address: l
j City l State: Zip:
Contact Name:
Contact Phone:
Contact E- Mail: 1 1 I k� l,✓ r� v►�et,• 0 ✓ e-,
I hereby acknowledge that I have read this application, filled out
in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to
comply with the information and plot plan, to comply with all Town
ordinances and state laws, and to build this structure according to
the town's zoning and subdivision codes, design review ap-
proved, International Building and Residential Codes and other
ordinance of the Town livable thereto.
Owner /Owner's Representative Signature (Required)
Applicant Information
Applicant Name: ,A 11 5 &v,_ T Q 1'�-Q� S
Applicant Phone: / ZO S 2-9 1`E5
�
Applicant E -Mail: 47 4 am-,
Project Information
Owner Name:
Parcel #: 0+'1 00.:a
(For Parcel #, contact Eagle County Assessors Office at (970- 328 -8640 or visit
www.eaglecounty.us/patie)
For Office Use Only:
Fee Paid: 4154S .A9
Received From:
Cash Check #
CC: Visa / MC Last 4 CC # exp date:
Auth #
R #: . '
Building
Lot #: Block# Subdivision: U&)PLIA-[TC_p
Work Class: New ( ) Addition ( )
Alteration )
I
Type of Building:
I Single - Family ( ) Duplex( ) Multi - Family (b( )
Commercial ( ) Other( )
Work Type: Interior Exterior (
\
) Both( )
_ i
Valuation of
Work Included Plans Included Work
Electrical ( )yes ( )No ( )Yes (X)No
Mechanical &Yes ( )No ( )Yes(
)No 15• o Z y
Plumbing Yes ( )No ( )Yes (
)No �o
Building )Yes ( )No ( )Yes (
)No
Value of all work being performed:
$ .
(value based on IBC Section 109.3 & IRC Section 108.3)
Electrical Square Footage
/
� 6 Z
Detailed Scope and Location of Work:
(use additional sheet if
Date Received:
ry) AUG 2'7 2012
V\VAJ
TOWN OF VAIL
State of Colorado
Asbestos Testing & Abatement Requirements
Asbestos testing and abatement protects workers, homeowners, neighbors and emergency services responders from ex-
posure to harmful asbestos. It is your responsibility to be in compliance with the State. Please contact the State directly
for their requirements at the contact info listed below.
When is asbestos testing required?
ANY building projects disturbing more than these threshold levels of building materials require asbestos testing:
One- and Two - Family Dwellings: 32 square feet
All Others (commercial spaces, hotel rooms, etc): 160 square feet
Definition of a single - family dwelling: any dwelling unit that is used primarily for a single family, including
multi - family /condominium units, and fractional fee units.
Asbestos testing results must be provided with your application for a building permit.
Tests which identify POSITIVE results at more than 1% require abatement by a State - certified abatement contractor. The
clearance letter must be submitted to the Town of Vail before the building permit will be issued.
Project Checklist
My proj ct falls into the category checked below:
Will not disturb more than the threshold limits identified above.
Tested negative, or at 1% or below (1 copies of test results included)
F] Tested positive at more than 1 %, requires abatement (1 copies of test results included)
Tips & Facts:
• Even recent construction projects may include asbestos - containing materials, so buildings of 4ny age require testing.
• The "1989 Ban" on asbestos - containing materials is commonly misunderstood. "In fact, in 1991 the U.S. Fifth Circuit
Court of Appeals vacated much of the so- called "Asbestos Ban and Phaseout" rule and remanded it to the EPA. Thus,
much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce
of many asbestos - containing product categories was set aside and did not take effect." - CDPHE
Asbestos test results and abatement permit applications should be submitted to: Town of Vail, Community Development,
75 S Frontage Rd, Vail, CO, 81657.
Town of Vail Contact:
Fire Prevention Bureau
Vail Fire Department
75 S Frontage Rd
Fire—inspectors@vailgov.com
970 - 479 -2252
www.vailgov.com
State of Colorado Contact:
Colorado Department of Public Health
and Environment
Asbestos Compliance Assistance Group
303 - 692 -3158
asbestos@state.co.us
www.cdphe.state.co.us
01- Jan -11
CBEnvirornmental, LLC
303 257 -8994 (Office) 303 235-0124 (Fax)
July 18, 2012
Mike Warmenhoven
P.O. Box 5923
Vail, CO 81658
Subject: Industrial Hygiene Support Services
Dear Mr. Warmenhoven:
CB Environmental, LLC (CBE) was retained by Mr. Warmenhoven to sample a building that is planned
for renovation activities located at 4695 Racquet Club Drive, Building 10 -Unit 2 in Vail, Colorado.
The asbestos survey included bulk sampling of suspect asbestos- containing material (ACM) observed on
the ceiling and wall surfacing and submittal of samples for asbestos content laboratory analysis. The
purpose of this inspection was to sample suspect ACM that would be disturbed by the renovation
activities and to have laboratory analysis identify whether the suspect material(s) contained asbestos. If
asbestos - containing, the materials) would then be removed properly by a General Abatement
Contractor (GAC).
Information researched by CBE indicated that the building was constructed in 1975. Asbestos -
containing building materials are more likely to be present in buildings constructed prior to 1979;
therefore, the subject building has a higher probability to contain ACMs. ACM is defined, by regulation,
to be materials that contain greater than I% asbestos.
Observations and Suspect Asbestos - Containing Materials at the Site
The limited scope survey was conducted on July 17, 2012, by Colorado Department of Public Health
and Environment (CDPHE) and Asbestos Hazard Emergency Response Act (AHERA) certified
inspector Ms. Michelle Lococo (Certification Number 19736).
The building is planned for renovation activities. Some minor destructive sampling was conducted on
the above referenced material locations planned to be disturbed. Two (2) suspect materials were sampled
in six (6) locations.
Samples were submitted to Aerobiology Laboratory Associates Incorporated (Aerobiology), laboratory
on July 17, 2012, for Polarized Light Microscopy (PLM) analysis to identify asbestos content. The
samples were requested on an immediate turnaround time for results.
355 S. Teller St, Suite 200
Lakewood, CO 80226
www.cbemvironmentalnet
Mike Warmenhoven
Asbestos Inspection
7/18/12
2
Laboratory results
Laboratory results received on July 17, 2012, document that zero (0) samples submitted contained
asbestos above the regulatory limit of 1 %.
Please find attached the Aerobiology laboratory report of PLM results.
Conclusions:
CBE observed two (2) types of suspect ACM that would be disturbed during the planned project
renovation. The ceiling and wall surfacing were sampled in six (6) locations at the building located at
4695 Racquet Club Drive, Building 10 -Unit 2 in Vail, Colorado.
Based on the site observations and, bulk sample PLM laboratory analysis results collected by CBE, zero
(0) samples contained asbestos above the regulatory limit of 1 %; therefore, removal of these areas will
NOT require asbestos abatement.
CBE recommends that when ACM is removed/abated, that only a licensed asbestos abatement
contractor using personnel trained in the handling of ACM be allowed to conduct such activities using
appropriate methods (HEPA- filtered vacuuming, wet cleaning methods, respiratory protection,
protective clothing, personnel decontamination, negative -air enclosures, air monitoring, etc).
Thank you for the opportunity to provide Mr. Warmenhoven industrial hygiene services. If you have any
questions on this limited scope asbestos building inspection, please contact me at your earliest
convenience.
Respectfully Submitted,
CBEnvironmental, LLC
Mike Lococo
Senior Project Manager
Attachments
Limitations:
This report describes the data collected and observations made by CBE during the visual inspection and bulk sampling in the above referenced building.
CBE represents that its services were performed within the limits prescribed by applicable regulations, within scope of work as approved by the EPA and in
a manner consistent with the level of care and skill ordinarily exercised by other professional consultants under similar circumstances. CBE accepts no
responsibility for data collected, the recommendations made or expressed to the client, and/or other commitments made by persons or firms other than CBE.
No other representation is made to the client, expressed or implied, and no warranty or guarantee is included or intended.
855 S. TeIIer St, Suite 200
Lakewood, CO 80226
wwwxbenvu-onmeirtaL
M
w
V O
a�i C
O
o
C
a> y-
3 � N
ORMW of Am*dm
Ilmw cdrw AW
su9e mr
r.t..,.r. menur
3133! 3M
vwwatfobkkerAd
Cial NOW
Cu FnNreuMnla
DNl c
(7171
9b,ad Ak.
355 4 TsW St Cc X11 W /
DbRto, iiW
(77.11
coy. tilau 2ii
IA..r*OA COXCM
D%U Amm, -Md
(717.13
Ant
Min Lom HYIAP1siCade MA6aU
D1M R(
]
(1140 FNI Nmul
ULd Ww*mhu -n 405 Rw4uA CM Dr Vul El)
PryaetlD
dm ID
1tH[grl8o
I2flum
1'.lIIII3134IR
ik ID
N
TarRqumrd. "a A "m in m &npia
mdwt Pds" Ai mhfiwm"y i Cipawus Ulms (FM k ('otlbd I:rON Dnhnrirdimul',WWrs w RA imWnc hliwillr, FFA- (QI:'R "91'114 hl5 IW.
Smrpk Haiirka"
M.wial Geryjwiln >< llrpe'Lr:cr
` m.
i...
15N'
lla:-
,l41rc91u Denid
.."" Parw dw
Nam -rile"
Floc
h 1
"Alan
Psrn
111&k
IAACMA
1.m rltr.9
1
'
11(11
IafflLill9 IA
Wtile Terse
N
r.
IJD
�
?
1'.lIIII3134IR
UfletaTixum
N
V
tiD
lrlr
1_tUf16315611'
1Y11 le )eels CCKWjnl
N
510
VD
IUD
c
1_r1L1833�ID
Uft'f1nD -rNdl
N
me
VD
IS
i5
0
.4191:
I_'(C1838%2A
While falurir u'WhicNil
N
Ire
VD
IUD
C.G
1ZIL133ig2B
t111itel "1n17y79d1
N
We
SID
15
55
G
All
12U]8 -W3A
Whit fakir( v W1ite Will
N
Nre
YD
lrm
Co
120(13334"30
KhteT)nl}1>+dl
N
Iwo
YD
IS
5S
Ci
13111
128. W4A
Whole f4mlurr v`'M'Irle Poitl
N
t-q
Yp
lrx
C
12f1u63tS1,+1B
11>tiiue"fmL}rwdl
N
9?`.
!Ib
IS
iS
C1
Pam 1)13
Q rts a P - Pair
C - C m" b Hndw
U - D Dwwm
hl ici
r -U
NIT - N3.1i1DSa Am 71
NAC • Noe•A d*sifrm .0
to
Wy
00
�g
� � U
4 - Mosis
AC -14b; iM
AN -
`
CHr - k
CL-C22rk
IR wImldL
laieeNry dyn
10,
ull. Ckma rystpelvAW
RD ■tae Dekaec
1.49:3310. ila&..Me 311h 736.lAi;max 302W,14&
Q rts a P - Pair
C - C m" b Hndw
U - D Dwwm
hl ici
r -U
NIT - N3.1i1DSa Am 71
NAC • Noe•A d*sifrm .0
to
Wy
00
�g
� � U
It
A dkm
AA a4"6" y [attt4ROrey
ASSOCNIES. IIYCX�'QtiAT[D
.ati6am MAMA
Ccaift-we a An713ih
13"9 Cobs, Aye
sure s«
-W ?3' 37.5
ffi
cum Num
CDb"Vi"Im"Ill f1nf.,, - --
Drl.cornwL
:x17-112
911,00 Ostrom
115 S T.11" 1, cle 200 I 11a�Jl
Dow F^ -dvW:
:11 792
CW9. sum Z111,
IAWI O9). Co ®275
Dow Aau42Mt
:7I112
A.nr:
Mitvl a N411AP ,ab i.J. iialti,q
Dwc Cp•wW:
:717.12
I:Mrri} P"� Homer
MiAw- Wanwmlw.m 4M4 RaaNus CU Ih %al. Co
IMy. -rl III:
121aRIR9
IY1<W.if4•i1j
Wtv.1, Terttre xV7hrt Pam
l�n ul.
11M.
Its: F,E4-1 JIAI ASx -b ba Mammon
V.ah.d Pdar w1 00,1 N11 --Iy D4wn.a9lrirrg('tdll, "Na11ea1 01111 the:Ylwwliwhter d,AAC4+ lb:.Ip„klar_\h&,wk f.Pi -rile R -9, IIG. 1.1, 1791
SjMk,IdRriCleulSn
Ptnwr�l lle.Ylriar d XMVL I , Ca
`3in
Qnw.t�.
h.
Inu
Paxtsrlrl�
lehewu. Vkeft- +d
W-1—
,- .tih�1e N.•rli-
MM-1
Von,
%UA—1
C.nr
CI -I
ah ti.0 i_ \vnhn
uii?
t`{HtiI1� +•'A
WhicTaK
N
1011,
GI)
lakwum An"
r {
-
IY1<W.if4•i1j
Wtv.1, Terttre xV7hrt Pam
N
11M.
itI?
IM
('
I?II(1�3iS1lC
11'hlh Juut:<lmpiursl
N
W0
UD
111)
C
11^110
InIQL3194,A
MawTt.Are A 14hrCImi,
N
51.
I.I)
lU1
C
I'_tx�.1f9 -L13
'AFu6eiar I h1 u rl l
N
+i ".
R I?
h
B9
t.
Q n
Q • QW3: P• FHf1e
C - CwhwA.�
O - QyQrran Q:1),ar
M- IJi u
T -Tr
VTR - Nw ,A.Ixwirum TR
go
�O
� � q
CYJ
Irna'll.'
+
111111;5-
IC LtinJtl:
_ 4.n hulini itc
i �a� A\
> .�
O
125 +��
fr /Y�'7►,— CI[lii lbn,.ut lc
O
Ck C'ta:ilulik
t y
C
TR 7rrnr4nr
w Twr:e-1.., TLw I`.•
w d
lakwum An"
urwviw ND -Wan? 171twed
3 O ty
139 -•94. Cif Aw. Siiw Dal. Lalao+a4 I'D MAIL 011;.,223715
y
NOV 2d9
Q n
Q • QW3: P• FHf1e
C - CwhwA.�
O - QyQrran Q:1),ar
M- IJi u
T -Tr
VTR - Nw ,A.Ixwirum TR
go
�O
� � q
CYJ
Mike Warmenhoven
Asbestos Inspection
7/18/12
ATTACHMENT B
CERTIFICATIONS
7�
4
7
llilt,
s
' ! t z
�1!
it
i t
:z a
F,
t
5
355 S. Teller St., Suite 200
Lakewood, CO 80226
www.cbenvironmental.net
i
Model Foal Oplim High Law MW. aftlenctr Vent System Approval & Requirements
This fireplace is approved for the following vent systems:
Nicdlet NG 12,500 4,500 79.70% Simpson Dora- Vent T. DV -GS Pipe - 5" x 8"
LP 12,500 4 ,500 80.50% Selkirk Metalbestosw - 5" x 8"
Amed -Verdw - 5" x 8"
The Nicollet comes standard with an electronic ignition pilot system. The included Metal FabT - 5" x 8"
thermostatic remote control will adjust the flame, fan speed & back lighting - fan kit IS ICCT - 5" x 8"
an optional accessory. SecudtyT - 5" x 8"
Features RLHTm - 5" x 8"
Canada P -4 approved
Electronic ignition pilot system - standing pilot option as well EIS: For each additional elbow used after the first 2 elbows,
Ceramic litetime glass (21" X 14 ") quick4atch removal 3' must be subtracted from the maximum venting allowed.
Remote control - (flame, light & fan adjustment) Note (2) 45' elbows =(I) 90' elbow.
2- receptacle assembly for wiring
Black enamel firebox liner Horizontal Terminations
Light kit bottom Minimum: 9(r elbow +termination cap Ma>enum: 20'
Engineer -designed burner system A horimnW Vend heat shield, that is included with the fireplace,
Minnesota Energy Code Compliant to 50 pascals must be installed when using a 90' elbow directly off top of fireplace.
Required for Installation* IMPORTANT: Nozy Heat part #800- WProrM@ -WFr2,
Rectangular or convex contemporary frameHace- Must be used on ALL horizontal vent runs.
Measurements - 21 1/16 "w x 33 3/8 "h #800 -WPT Wii - 6W wall thickness)
(black, rust, titanium or brushed stainless) #800 -WPF2 = 6th" - 1254" wall thickness
Glass media kit (various colors available)
Door faces offered for the model 'Iwo Harbors' can also be used Vertical Terminations
Safety Minimum: 3' Maximum: 36'
Each welt factory tested! Horizontal/ Vertical COMB_ O_:
Tested by PFS Corp. 20' horizontal / 20' vertical`
Complies with ANSI- 121.88a - 2009•CSA 2.33 -2009 P.4.1 -09
'Vented Gas Fireplace heaters' Please consult the venting chart in the installation manual.
U.S. & Canadian installation approved
Sealed combustion chamber
Removable control board with safety pilot
Automatic pressure relief glass system
Bedroom & mobile home approved
r1.
TP FrW — Left 1
7"
r
�'4" 31Y{ ' 21
I
1458" 23J.
2 QUALITY FIREPLACES FOR LIFE tgy�"
sue- --
Height
31I/r
Width
1812"
Back width
51/4"
Depth
14 3B"
Weight
761..
Fraleing Dimensions
Height t
32 W
Width
19 34"
Depth
14 7l8"
Clearances
Fireplace face top to framing
1"
Fireplace left & right sides
& hack
From decorative face lop
(n order to remove face)
1/4"
Fireplace bottom to flooring
0"
Fueplace base toceiling
52"
Fireplace side stand -offs to
0
adjacent sidewa0
Top of fireplace to 314"
projection
21/4"
Mantel must be a minimum of 7 W from
top of fireplace fare. The maximum depth
at this height is 12 ". See additional mantel
cleararnce configurations in the installation
manual.
9W 2Y'
0
rl4V"
I•
CONDENSING RESIDENTIAL GAS BOILERS
LL55 1 HAN 20 ppM NUX
DIRECT VENT FLEXIBILITY TO 100 FEET
UP TO 98% EFFICIENCY IN LOW TEMP
APPLICATIONS
A
o
High EfficiencyyVater Heaters, Boilers and Pool Heaters
UP T096%
AFUE EFFICIENCY
k nigh th eat i ngbo i I er.co m
KNIGHrBOIL_R DIMENSIONS AND SPECIFICATIONS - FLOOR- STANDING MODELS
Models:
KBN 081.211
A
nnwst��
FRONT
WALL- -MOUNT MODELS
0
R Mx w.ET
SM a,7
Models:
WBNOS11-211
KBN286 57 285 %.0 260 226
t9-114 15 -i/4- RA 1D -3147 10 -3/4' 2- 63/4' NA 3 -1/4 4-1/ 2 -3/4 1R 1 2 130
29-1/4' 15-3/4 NA 10-31 1Q 314 31 51 NA 3 -114 4-14 2 -3/ 1 1 134
2:1 4203/ NA 15-3/4 81 3 -t 51 NA 8 3/4 9 3/ 11 1 1 3
33 -1 1 12l/ 111 fijl 1 1- 21 -i /4 23 13/ 1 NA 1 1, 157
33-1/4 22 -11 16.1 15-31 14-1111' SAW 21-114- 23 1 -3/ 16-11 NA iR 1 3
41 -114' 19 -3/4' 12 -314' 13-1R' 6' T 34' 31' 11 -314' 41/4' NA 3/4' 1 -1/4 4' r 224
Notes: Indoor installation only. All information subject to change. Change *N' to 'L' for LP gas models.
SMART SYSTEM"° FEATURES
> SMART SYSTEM Digital Operating Control
Multi -Color Graphic LCD Display
with Navigation Dial and Soft Keys
Three Setpoint Temperature Inputs
Built -in Cascading Sequencer for up to 8 Boilers
Cascade Multiple Sized Boilers
Lead Lag
Efficiency Optimization
Outdoor Reset Control with Outdoor Air Sensor
Programmable for Three Reset Temperature Inputs
Programmable System Efficiency Optimizers
Night Setback w /Overide Function
DHW Night Setback w /Overide Function
Anti- Cycling
Outdoor Air Reset Curve
Ramp Delay
Boost Temperature & Time
Three Pump Control
System Pump with Parameter for
Continuous Operation
Boiler Pump with Variable Speed Pump Control'
Domestic Hot Water Pump
Domestic Hot Water Prioritization
DHW tank piped with priority in the boiler loop
DHW tank piped as a zone in the system with
the pumps controlled by the Smart System
DHW Modulation Limiting
Separately Adjustable SH /DHW Switching Times'
Building Management System Integration
0 -10VDC Input to Control Modulation or Set Point
0 -10VDC Modulation Rate Output
0 -10VDC Input Signal from Variable
Speed System Pump*
0.10VDC Input to Enable /Disable call for heat
'Exclusive feature, available only from Lachinvar
> High - Voltage Terminal Strip
> 120 VAC / 60 Hertz / 1 Phase Power Supply
> Three Sets of Pump Contacts
> Low Voltage Terminal Strip
24 VAC Device Relay
Proving Switch Contacts
now Switch Contacts
Alarm on Any Failure Contacts
> Runtime Contacts
> DHW Thermostat Contacts
3 Space Heat Thermostat Contacts
System Sensor Contacts
DHW Tank Sensor Contacts
> Outdoor Air Sensor Contacts
> Cascade Contacts
> 0 -10VDC BMS External Control Contact
0 -10VDC Boiler Rate Output Contacts
0 -10VDC Variable Speed System Pump Signal Input
> 0 -10VDC Signal to Control Variable
Speed Boiler Pump
Modbus Contacts
> rime Clock
> Data Logging
> Hours Running, Space Heating
Hours Running, Domestic Hot Water
Ignition Attempts
> Last 10 Lockouts
> Access to BIAS Settings through Graphic LCD Display
> Maintenance Reminder
> Custom Maintenance Reminder with Contractor Info
> Installer Ability to De- activate Service Reminder
> Low-Water Flow Safety Control & Indication
> Dual Level Password Security
> Customizable Freeze Protection Parameters
STANDARD FEATURES
> Energy Starr" Qualified
> Up to %% DOE AFUE Efficiency
> Modulating Burner with 5:1 Turndown
> Direct -Spark Ignition
Low -NOx Operation
> Feld Convertible from Natural to LP Gas
> ASME Stainless Steel Heat Exchanger
> 30 psi ASME Relief Valve
> Vertical & Horizontal Direct -Vent
> PVC, CPVC, Polypropotene or SS Venting up to 100 feet
> Factory Supplied Sidewall Vent Termination
> Smart System Control
> Condensate Trap
> Other Features
> Automatic Reset High Limit
> Adjustable High Limit w /Manual Reset
> Boiler Circulating Pump
> Adjustable Leveling Legs (KB Models only)
> Wall -Mount Bracket (WB Models only)
> Zero Clearances to Combustible Materials
> 12 -Year Limited Warranty (See Warranty for Details)
OPTIONAL EQUIPMENT
> Modbus Communication
> Condensate Neutralization Kit
> Multi Temperature Loop Control
> Flow Switch
> Low -Water Cutoff w /Manual Reset & Test
> Alarm Bell
> Concentric Vent Kit
SMART SYSTEM PC Software
> Stack Frame
FIRING CODES
> M9 Standard Construction
> M7 California Code
ru
T w
An R1 . l' •
M E M B E R patent Pending f�\/ j-fll
_ IIIeYElnriesrcwmrBatas .BaaenW Hd HeHen
ou
n.>
rz
os
WBN106
21
105
95.4
94
82
W13Ni51
30
150
955
"1
119
WBN211
42
210
95.7
190
165
0081
16
80
953
72
63
KBN106
11
105
95.4
94
82
KBN151
30
150
953
135
119
KBN211
42
210
95.7
190
165
KBN286 57 285 %.0 260 226
t9-114 15 -i/4- RA 1D -3147 10 -3/4' 2- 63/4' NA 3 -1/4 4-1/ 2 -3/4 1R 1 2 130
29-1/4' 15-3/4 NA 10-31 1Q 314 31 51 NA 3 -114 4-14 2 -3/ 1 1 134
2:1 4203/ NA 15-3/4 81 3 -t 51 NA 8 3/4 9 3/ 11 1 1 3
33 -1 1 12l/ 111 fijl 1 1- 21 -i /4 23 13/ 1 NA 1 1, 157
33-1/4 22 -11 16.1 15-31 14-1111' SAW 21-114- 23 1 -3/ 16-11 NA iR 1 3
41 -114' 19 -3/4' 12 -314' 13-1R' 6' T 34' 31' 11 -314' 41/4' NA 3/4' 1 -1/4 4' r 224
Notes: Indoor installation only. All information subject to change. Change *N' to 'L' for LP gas models.
SMART SYSTEM"° FEATURES
> SMART SYSTEM Digital Operating Control
Multi -Color Graphic LCD Display
with Navigation Dial and Soft Keys
Three Setpoint Temperature Inputs
Built -in Cascading Sequencer for up to 8 Boilers
Cascade Multiple Sized Boilers
Lead Lag
Efficiency Optimization
Outdoor Reset Control with Outdoor Air Sensor
Programmable for Three Reset Temperature Inputs
Programmable System Efficiency Optimizers
Night Setback w /Overide Function
DHW Night Setback w /Overide Function
Anti- Cycling
Outdoor Air Reset Curve
Ramp Delay
Boost Temperature & Time
Three Pump Control
System Pump with Parameter for
Continuous Operation
Boiler Pump with Variable Speed Pump Control'
Domestic Hot Water Pump
Domestic Hot Water Prioritization
DHW tank piped with priority in the boiler loop
DHW tank piped as a zone in the system with
the pumps controlled by the Smart System
DHW Modulation Limiting
Separately Adjustable SH /DHW Switching Times'
Building Management System Integration
0 -10VDC Input to Control Modulation or Set Point
0 -10VDC Modulation Rate Output
0 -10VDC Input Signal from Variable
Speed System Pump*
0.10VDC Input to Enable /Disable call for heat
'Exclusive feature, available only from Lachinvar
> High - Voltage Terminal Strip
> 120 VAC / 60 Hertz / 1 Phase Power Supply
> Three Sets of Pump Contacts
> Low Voltage Terminal Strip
24 VAC Device Relay
Proving Switch Contacts
now Switch Contacts
Alarm on Any Failure Contacts
> Runtime Contacts
> DHW Thermostat Contacts
3 Space Heat Thermostat Contacts
System Sensor Contacts
DHW Tank Sensor Contacts
> Outdoor Air Sensor Contacts
> Cascade Contacts
> 0 -10VDC BMS External Control Contact
0 -10VDC Boiler Rate Output Contacts
0 -10VDC Variable Speed System Pump Signal Input
> 0 -10VDC Signal to Control Variable
Speed Boiler Pump
Modbus Contacts
> rime Clock
> Data Logging
> Hours Running, Space Heating
Hours Running, Domestic Hot Water
Ignition Attempts
> Last 10 Lockouts
> Access to BIAS Settings through Graphic LCD Display
> Maintenance Reminder
> Custom Maintenance Reminder with Contractor Info
> Installer Ability to De- activate Service Reminder
> Low-Water Flow Safety Control & Indication
> Dual Level Password Security
> Customizable Freeze Protection Parameters
STANDARD FEATURES
> Energy Starr" Qualified
> Up to %% DOE AFUE Efficiency
> Modulating Burner with 5:1 Turndown
> Direct -Spark Ignition
Low -NOx Operation
> Feld Convertible from Natural to LP Gas
> ASME Stainless Steel Heat Exchanger
> 30 psi ASME Relief Valve
> Vertical & Horizontal Direct -Vent
> PVC, CPVC, Polypropotene or SS Venting up to 100 feet
> Factory Supplied Sidewall Vent Termination
> Smart System Control
> Condensate Trap
> Other Features
> Automatic Reset High Limit
> Adjustable High Limit w /Manual Reset
> Boiler Circulating Pump
> Adjustable Leveling Legs (KB Models only)
> Wall -Mount Bracket (WB Models only)
> Zero Clearances to Combustible Materials
> 12 -Year Limited Warranty (See Warranty for Details)
OPTIONAL EQUIPMENT
> Modbus Communication
> Condensate Neutralization Kit
> Multi Temperature Loop Control
> Flow Switch
> Low -Water Cutoff w /Manual Reset & Test
> Alarm Bell
> Concentric Vent Kit
SMART SYSTEM PC Software
> Stack Frame
FIRING CODES
> M9 Standard Construction
> M7 California Code
ru
T w
An R1 . l' •
M E M B E R patent Pending f�\/ j-fll
_ IIIeYElnriesrcwmrBatas .BaaenW Hd HeHen
irect Water Heaters
sS' n
6(�' �kAt
Model
Storage
Volume
Gals.
Coil
Heating
Surface
. Ft
Dimensions
(inches)
Ht Dia.
Piping Connections - N.P.T.
Domestic Boiler
Water Water
INOut In/Out
Max.
Working
Pressure
(psi)
Approx
Shipping
Wt -Lbs.
30
30
7.0
34.0
23.5
3/4
1
150
85
40
40
7.5
44.0
23.5
3/4
1
150
100
40L
42
7.1
36.0
28.0
3/4
1
150
100
50
50
8.0
54.0
23.5
3/4
1
150
110
60
60
8.3
62.0
23.5
3/4
1
150
125
60L
60
7.5
46.0
28.0
3/4
1
150
120
80
80
8.0
56.0
28.0
1
1
150
140
115
115
8.9
74.0
28.0
1
1
150
175
HighOutp ut Units 80 -HO and 115-HO
80 -HO
1 80
1 13.4 1
56.0
28.0
1 1
1
150
155
115 -HO
115
1 14.4
74.0
28.0
1
1
150
190
80 -HO -C
80
1 13.4
56.0
28.0
21.0
1 1/4
150
155
11 -1-10-C
115
1 14.4
74.0
28.0
1 11/2
11/4
150
190
HOT OUTLET &0
BOILER RETURN
T.PVALVE
Bn
O
DON. COLD INLET BORER SUPPLY
O
O
STANDARD U WS
3/4' NPT BB
RECIRC PORT
T.PgLL11E
11/2' NPT
HOT OUTLET I
1 1/4� NPT - 1 114' NPT
809-ER SUPPLY BOLER RETURN
112' NPT
LOA COLD INLET
C UNITS
Model
Max. First
Hour Rating
Gal. /Hr. @
Continuous
Rating
Gal./Hr. @
Boiler
Output
Required
Min. Boiler
Water Flow
Through Coil
Pressure
Drop
Through Coil
140 F
115 F
140 F
115 F
BTU/Hr.
Gal. /Min.
FtWater
30
195
259
168
232
125,600
14.0
5.3
40
215
284
179
248
134,200
14.0
5.7
40L
195
259
168
232
1 125,600
14.0
5.3
50
234
308
189
263
129,900
14.0
6.0
60
254
333
200
279
151,000
14.0
6.2
60L
233
302
179
248
134,100
14.0
5.7
80
266
341
194
269
145,600
14.0
6.0
115
319
403
216
300
162,400
14.0
6.6
High
Output Units 80 -HO and 115-HO
80 -HO
386
507
314
435
235,600
14.0
9.9
115 -HO
439
568
336
465
251,700
14.0
10.5
80 -HO -C
408
537
336
465
251,700
21.0
15.8
115 -HO -C
450
583
347
480
259,800
21.0
16.7
Note: All Ratings are based on 200 degree F boiler water supply and 50 degree F cold Water inlet.
For 180 degree F boiler water supply multiply by ratings by 0.86
In the interest of continuous improvement, specifications are subject to change without notice.
WWW.hoat- flo.com �� i _ Heat -Flo
HEATING PRODUCTS f
BRUSH CREEK
E L E C T R I C, I N C.
Proposal
To Mike Warmenhoven
From : George S. Henry
Date : 19 July, 2012
Re Electrical Estimate for Alfers Residence, Building 10, Unit 2, Vail
Racquet Club
The price for Alfers remodel is This project includes 450 square feet,' r
The price does not include any demolition. All required framing is by others.
Included in the estimate are the following:
1. Remove existing panel and replace with 20- circuit main lug only interior panel and
new breakers.
:_I_ LI � n
a. Five (5) overhead lights
b. One (1) switch
3. Water Closet
• Page 1
Brush Creek Eectric. Inc. Warmenhoven: A Jars Residence Page 2 of3
a. Two (2) overhead lights
b. One (1) shower light
c. Two (2) switches
4. Vanity
a. Remove existing light
b. Add two (2) sconces
c. Add one (1) GFCI receptacle
d. Relocate one (1) switch
e. Install 39 square feet of floor heat and thermostat
5. Kitchen
a. Install four (4) downlights
b. Install two (2) single -pole switches
c. Cooktop: wire for second small appliance circuit
d. Microwave: install wiring
e. Dishwasher: install wiring
f. Install 16" unde abinet light
g. Install 35 square feet of floor heat and one thermostat
6. Living Room
a. Install three (3) downlights
b. Install two (2) wall washers
c. Fish receptacle for wall - mounted television
d. Fish CATV feed for wall- mounted television
7. Boiler Room
a. Wire boiler
b. Wire new side arm
• Page 2
Brush Creek Electric, Inc. Warmenhoven: Alfers Residence Page 3 of 3
8. Replace all existing receptacles and switches with new Decors devices
Thank you for the opportunity to bid on this project!
• Page 3
Alfer Residence Load Calculation
Building 10, Unit 2, Vail Racquet Club
525 sq ft X 3 VA
1575
First 10,000 VA at 100%
10000
Small Appliance x 2
3000
Next 12,925 VA at 40%
5160
Laundry
0
total
15160
Range
12000
Disposal
1200
AMPS (15160/208)
72.9
Dish Washer
1600
Refrigerator
1000
Microwave / Hood
1550
Unde Tile Heat
1000
Total
22925 VA
The unit is heated by a gas boiler; DHW Heat is by a boiler side arm; There is not a laundry room.
All Pro 1499 ICT
All Pro 1493 Trim
Sylvania 37wMR16 IR
Tenent Fibre Fire Hat
Lighting Efficacy
19 LED Undercabinet Lighting
0.13 watt lamps x 26
GEORGE S. HENRY
Owner
BRUSH CREEK
E L E C T Q I C. I N C.
CO. Box 125 • 1: iglr. Colorado 81631 -0125
Telephone: (970) 328 -2254
Fax: (970) 328 -2440
Cell: (970) 390 -6327
E -Mail: george @brushcreekelectric.con,
/ I
i>547_ W a
12 -11 -2012 Inspection Request Reporting ( Page 9
4:0312m Vail. CO - City Of W"Tiz-c49 -I
Requested Inspect Date: Wednesday, December 12, 2012
Site Address: 4640 MEADOW DR VAIL
VAIL RACQUET CLUB BUILDING 10 UNIT 2
A/P /D Information
Activity: B12 -0391 Type: COMBO Sub Type: AMF Status: ISSUED
Const Type: Occupanc : Use: Insp Area:
Owner: ALFERS, STEPHEN D. & J. ALION
Contractor: MIKE WARMENHOVEN CONSTRUCTION Phone: 970 - 390 -0411
SERVICES
Description: INTERIOR REMODEL, NEW LIGHTING LAYOUT, NEW MECHANICAL EQUIPMENT.
Requested Inspection(s
Item:
Requestor:
Comments:
Assigned To:
Action:
Item:
Requestor:
Comments:
Assigned To:
Action:
CONSTRUCTION
Time Exp:
CONSTRUCTION
Time Exp:
Item:
390 MECH -Final
Item:
Requestor:
MIKE WARMENHOVEN
CONSTRUCTION
200 MECH -Rough h
09/26/12- Inspector:
Comment:
SERVICES
Item:
Comments:
Assigned To:
390 -0411
SGR
Action:
sgremmer
Time Exp:
230 PLMB- Rough/Water
09/26/12 Inspector:
Comment:
** Approved **
sgremmer
Item:
Inspection History
Item:
120 ELEC -Rough
09/17/12 Inspector:
Comment:
** Approved **
mdenney
Item:
200 MECH -Rough h
09/26/12- Inspector:
Comment:
** Approved **
sgremmer
Item:
220 PLMB - Rough /D.W.V.
** Approved **
09/26/12 Inspector:
Comment:
sgremmer
Item:
230 PLMB- Rough/Water
09/26/12 Inspector:
Comment:
** Approved **
sgremmer
Item:
240 PLMB -Gas Piping
09/26/12 Inspector:
Comment:
** Approved **
sgremmer
Item:
310 MECH - Heating
09/26/12 Inspector:
Comment:
** Approved **
sgremmer
Item:
30 BLDG - Framing
REPT131
Requested Time: 01:00 PM
Phone: 970 - 390 -0411
Entered By: JMONDRAGON K
Requested Time: 10:30 AM
Phone: 970 - 390 -0411
Entered By: JMONDRAGON K
Requested Time: 11:00 AM
Phone: 970 - 390 -0411
Entered By: JMONDRAGON K
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
Run Id: 14623