HomeMy WebLinkAboutB12-0392 SPECIAL INSPECTIONS Job Name: VVMC Trash Enclosure
' Job Address: � 81 West Meadow Drive
�wN�F yf�' Permit No.:
SPECIAL INSPECTION AND TESTING AGREEMENT
(To applicants of projects requiring Special Inspection or Testing per Section 1701 of the IBC)
The owner or his/her representative, on the advice of the design professional in responsible charge, shall
complete, seal, sign and submit a copy of the Special Inspection Agreement and SVUCtural Tests
Scheduled to the Town of Vail for review and approval. Signatures are required on both pages;
photocopied or faxed signatures are acceptable.
The owner and his/her general contracfor, where applicable, shall also acknowledge the following
conditions applicable to Special Inspection Testing:
1 . Contractor is responsible for proper notification to the Inspection or Testing agency for items
listed.(Page 1 ) (IBC 1704)
2. Only the testing laboratory should take samples and transport them to their laboratory.
3. Copies of all laboratory reports and inspections are to be sent directly to the Town of Vail by the Testing
agency on a weekly basis.
4. Inspection agency to submit names and qualifications of on-site special inspectors to the Town of Vail
for rev�ew and approval.( Page 2)
5. The special inspector is responsible to immediately notify the Town of Vail Building Official in writing of
any concems and/or problems encountered.
6. It is the responsibility of the contractor to review the Town of Vail approved plans for additional
inspection or testing requirements that may be noted. A pre-construction conference at the job site is
recommended to review special inspection procedures.
7. The special inspector shall use only the Town of Vail approved drawings.
8. All special inspeclion field reports must be left on site for review by the Town of Vail staff prior to
required inspections or re-inspections.
BEFORE OCCUPANCY WILL BE GRANTED: The special inspection agency shall submit a signed and
sealed statement that all items requiring tes6ng and inspection were fulfilled and reported. Those items not
tested and/or inspected shall be noted in this statement. A copy of the statement shall be maintained at the
job site for fhe Building Inspector's review prior to final inspection.
Acknowledger�M.
owner: Ryan Magill 8/22/2012
gnatur Print Name Date
Speciallnspection J n/'� } � ,� /�/
Agency: �����. lTt.OTe�' . G�-�V` 2 � � Z
Sinnahire C^�Lc .�� prin, Nam�Q � '�� Date
Project �� � `^' �-
Arch/Eng: _ � � Paul Doak, P.E. � g/Z7�Zp� 2
Signa[ure Prin[ Name Date
contracto� Ryan Magill 8/22/2012
Signatur Print Name �ate
-3-
i
TC�WNOF �AII, � SPECIAL INSPECTION AND TESTING SCHEDULE
(IBC 1704)
Project Name: WMC Trash Enclosure Permit #
Owner'sName: _— _ Ryan Magill 8/22/2p12
Testing Inspec6on ignature PrintName oate
Agency:
Testing Inspec6on signature printName oate
Hereby certifies thal the Teslingllnspection Agency named above has been engaged to perform slructural tests and
inspections during construction as checked below, to satisfy all applicable portions of the Building Code.
Prior to final inspection, the Inspection Agency shall submit a statement [hat all items of designated work performed
were reported. My items checked but not tested or inspected will be noted and explained. W henever any designated
items on the list are ready for sampling, testing, or inspection, it shall 6e the responsibility of the contractor to give
timely notice to the Inspection agency so that the required services may be performed.
REINFORCING STEEL: UNDERPINNING:
Tensile & Bend, one set per heat per_ tons _ TemporarylPermanent
� Inspeclion of Placement _ Inspection of Steel Fabricalion
_ inspection of Welding _ Inspection of Reinforcing & Forms
_ Epozy _ Inspection of Concrete Placement
_ Inspection of Tiebacks
MASONRY:
_ Prelim. Acceptance Tests (Masonry Units, Wall Prisms) _ SOIL NAILS:
_ Subsequent Tesis (MOrtar, Grout, Field Wall Prisms) _ Temporary Shoring
_ Inspec6on of Placement and Grouling _ Permanent Wall
CONCRETE, SHOTCRETE, GROUTANO MORTAR: STRUCTURAL STEEL:
Concrele Shot Grout Mortar Sample & Test (List spec�c members below)
Aggregatetestsiordesign -� Shopldentification & Weldinglnspection
Suitabiliry of aggregates _ Shop Ultrasonic Inspeclion
M& Designs Shop Radiography
TesiPanel �. – FieldWeldinglnspection
Balch Plant Inspection _ Field Bolting InSpecti0n
CementGrabSample _ FieldUllrasoniclnspeclion
Inspect Placing _ Field Radiography
X Compression Tesls — Metal Deck Weltling Inspection
CastSpecimens FIREPROOFING:
Pick-up Samples Inspeclion & Placemen[
Shrinkage Bars —
YieldCheck SOILS:
AirCheck X AcceptanceTests
�ry Unit W eight Moisture-Density Detertnination
PRECAST CONCRETE: Field Density
_ Reinforcing Tests Drilled Piers
_ Inspeclion of Reinforcing Placement �eep Foundation
Tendon Tes[s —
_ InspectionotTendonPlacement S7RUCTURALWODD:
_ Inspection oi Concrete Placement InspecHon of Fabrication
_ Inspec[ion of Concrete Batching Inspection of Tmss Joint Pabrication
_ Inspection of Panel Attachment 8 Inserts Sample 8 Test Components
_ Compression 7ests Inspection of Glu Lam Fahrication
_ Inspection of Stressin9?rensfer —
SMOKE CONTROL:
PILING, CAISSONS, CAPS, TIES: —
_ Inspec6on of Reinforcing Placement SPECIAL CASES:
_ Inspection of Concrete Placement —
Inspection of Concrele Batching SPECIAL INSPECTION:
_ - _ _ _. _ _ _ - _— _ _ _ .. _ _ _ _ _ _ _ . _ _ _ _ _ _ _ _ _ . _ - _ _ _ - _Seismic Resistance . _ . _ .. . . _ _ . . . . . . . .
Speci(yothertests, inspectionsorspecialinstructionsrequired. _ VyindRequirements
-4-