Loading...
HomeMy WebLinkAboutF12-0046 BREAKAWAY WEST DATA SHEETSModelRFC43Concealed ResidentialSprinkler (SINRA0612) AConcealedResidential Sprinklerengineeredfora minimumdesigndensity of0.05gpm/ft2 withlowGPM requirements. Features 1.Verylowwaterflowrequirements. 2.½(13mm)Totaladjustment. 3.Push-On/Thread-Off coverattachmentoption. 4.Smoothaestheticceilingprofile. 5.Availableinbrass,chromeand blackplatedorpaintedfinishes. ProductDescription ModelRFC43ConcealedResidentialSprinklersarefast responseresidentialfusiblesolderlinkautomaticsprinklers. Residentialsprinklersdifferfromstandardsprinklersprimarily intheirresponsetimeandwaterdistributionpatterns. ModelRFC43sprinklersdischargewaterina hemisphericalpatternbelowthesprinklerdeflector. Residentialdistributionpatternsarehigherandgenerally containafinerdropletsizethanstandardsprinklerpatterns. Thecombinationofspeedofoperationandhighdischarge patternrequiredforresidentialsprinklershasdemonstrated, infiretesting,anabilityforcontrollingresidentialfires,and therebyprovidingsignificantevacuationtimeforoccupants. TheRFC43Sprinklerprovidesthebestformoffire protectionbycombininganattractiveappearanceand½ (13mm)ofcoveradjustmentforeaseofinstallation.The smalldiametercoverplateiseasilyandpositivelyattached andblendsintotheceiling,concealingthemostdependable fireprotectionavailable,anautomaticsprinklersystem. TheRFC43isaULListedResidentialSprinklertobe installedintheresidentialportionsofanyoccupancyin accordancewithNFPA13,13R,&13D. TheRFC43canreducetheneedforprecisecuttingofdrop nipples.Thethreadedcoverplateassemblycanbeadjusted withouttoolstofitaccuratelyagainsttheceiling.Thefire protectionsystemneednotbeshutdowntoadjustorremove thecoverplateassembly. ApplicationandInstallation TheRFC43,forresidentialinstallations,usesa165 F(74 C) fusiblesolderlinkinatuningforkstylesprinklerframewitha drop-downdeflector.Thisassemblyisrecessedintothe ceilingandconcealedbyaflatcoverplate.Thecoverplateis attachedtotheskirt,using135 F(57 C)ordinarytemperature classificationsolder.Whentheceilingtemperaturerises,the solderholdingthecoverplatereleasesthecoverallowingthe deflectortodropintopositionandexposingthesprinkler TheReliableAutomaticSprinklerCo.,Inc.,525NorthMacQuestenParkway,MountVernon,NewYork10552 Bulletin006 Rev.A Listings&Approval ListedbyUnderwritersLaboratories, andcertifiedbyULforCanada(cULus) ULListingCategories ResidentialAutomaticSprinklers ULGuideNumber VKKW Bu l l e t i n 0 0 6 Re v . A insidetoceilingtemperature.Thesubsequentoperationof thesolderlinkopensthewaterwayandcausesthedeflector todropintopositiontodistributethedischargingwaterina hemisphericalpatternbelowthesprinklerdeflector.Any adjustmentofthreadengagementbetweenthecoverplate andcupwillassurethatthedrop-downdeflectorisproperly locatedbelowtheceiling.Theresidentialdistributionpattern containsafinerdropletsizethanastandardsprinkler,andthe patternproducessignificantlyhigherwallwetting. Aftera25/8inchdiameterholeiscutintheceiling,the sprinkleristobeinstalledwiththeModelFCWrench.When installingasprinkler,thewrenchisfirstpositionedintothe sprinkler/cupassemblyandaroundthehexagonalbodyof thesprinklerframe.TheWrenchmustbottomoutagainstthe cupinordertoensureproper,safeinstallation.Thesprinkler isthentightenedintothepipefitting.Wheninsertingor removingthewrenchfromthesprinkler/cupassembly,care shouldbetakentopreventdamagetothesprinkler.DONOT WRENCHONANYOTHERPARTOFTHESPRINKLER/CUP ASSEMBLY.MODELRFC43CONCEALEDSPRINKLERS MUSTBEINSTALLEDONLYWITH135°FRATEDCOVERS. Coverassembliesprovideupto 12 (13mm)ofadjustment. Turnthecoverclockwiseuntiltheflangeisincontactwiththe ceiling.Theoptionalpush-oncoverplatemayrequireafinal adjustingturntocontacttheceiling.Coverremovalrequires turninginthecounter-clockwisedirection. Inceilingsthathaveaplenumspaceabovethesprinkler, theplenumspacemayhaveneutralornegative pressurizationbutmustnotbepositivelypressurized.Inspect allsprinklersafterinstallationtoensurethatthegapbetween thecoverplateandceilingandthe4slotsinthecupareall openandfreefromanyairflowimpediment. SprinklerCoverPlate Max.Ambient Temp. 165oF/74oC135oF/57oC100oF/38oC TemperatureRating ThreadSize inch(mm) K Factor Sprinkler Spacing ft.(m) Maximum Distance toWallft.(m) Minimum Distancebetween sprinklerft.(m) MinimumRequired SprinklerDischarge Flow gpm(Lpm) Press. psi(bar) ½(15mm) ½(15mm) ½(15mm) ½(15mm) ½(15mm) 4.3 4.3 4.3 4.3 4.3 12x12(3.6x3.6) 14x14(4.3x4.3) 16x16(4.9x4.9) 18x18(5.5x5.5) 20x20(6.0x6.0) 6(1.83) 7(2.13) 8(2.43) 9(2.74) 10(3.05) 8(2.43) 8(2.43) 8(2.43) 8(2.43) 8(2.43) 12(45) 13(49) 13(49) 18(68) 21(79) 7.8(0.54) 9.1(0.63) 9.1(0.63) 17.5(1.21) 23.8(1.64) InstallationData Note:1bar=100Kpa 2. Maintenance ModelRFC43ConcealedSprinklersshouldbeinspected quarterlyandthesprinklersystemmaintainedinaccordance withNFPA25.Donotcleansprinklerswithsoapandwater, ammoniaoranyothercleaningfluids.Removedustbyusing asoftbrushorgentlevacuuming.Removeanysprinkler coverplateassemblywhichhasbeenpainted(otherthan factoryapplied)ordamagedinanyway.Astockofspare sprinklersshouldbemaintainedtoallowquickreplacementof damagedoroperatedsprinklers.Priortoinstallation, sprinklersshouldbemaintainedintheoriginalcartonsand packaginguntilusedtominimizethepotentialfordamageto sprinklersthatwouldcauseimproperoperationor non-operation. OrderingInformation Specify: 1.SprinklerModel 2.CoverPlateFinish 3.Thread-Onor Push-Oncover StandardFinishes Chrome White SpecialApplication Finishes BrightBrass BlackPlating BlackPaint OffWhite SatinChrome CoverPlateFinishes (1) (1)Othercolorsandfinishes available.Consultfactory fordetails. Note:Paintoranyother coatingsappliedoverthe factoryfinishwillvoidall approvalsandwarranties. 3. ModelRFC43ResidentialConcealed SprinklerSpecification SprinklersshallbecULusListedlowflowresidential concealedsprinklerswithdrop-downdeflectorand adjustableflatcoverplateengineeredforaminimumdesign densityof0.05gpm/ft2.Sprinklerframeanddeflectorshallbe ofbronzeframeconstructionhavinga½”NPTthread. Thermalelementshallconsistofanapprovedblack-painted beryllium-nickelfusiblesolderlinkwithsymmetriclever mechanism,maintainingaTeflon-coatedBellevillespring washerandmachinedbrasscapwatersealassembly containingnoplasticparts.SprinklerK-factorshallbenominal 4.3(62.4),havinga7/16”orifice.Temperatureratingshallbe Ordinary165 F(74 C);coverplatetemperatureratingtobe 135 F(57 C).Coverplateassemblyshallconsistofabrass coverplateandcopperalloyretainerflangehavinga [thread-on][push-on]andthread-offdesign,allowinga½” coverplateadjustment.Anysecureengagementbetween thecoverplateandthecupwillassurethatthedrop-down deflectorisproperlylocatedbelowtheceiling.Aplastic protectivecapshallbeprovidedandfactoryinstalledinside thesprinklercuptoprotectthedrop-downsprinklerdeflector fromdamage,whichcouldoccurduringconstructionbefore thecoverplateisinstalled.Standardcoverfinish:[Chrome] [White][Specialty–specify].Residentialconcealedsprinklers shallbeReliableModelRFC43,SINRA0612(Bulletin006). Manufacturedby: Revisionlinesindicateupdatedornewdata E.G.PrintedinUSA.2/04P/N9999970261 Recycled Paper TheequipmentpresentedinthisbulletinistobeinstalledinaccordancewiththelatestpertinentStandardsoftheNationalFireProtectionAssociation,FactoryMutual ResearchCorporation,orothersimilarorganizationsandalsowiththeprovisionsofgovernmentalcodesorordinances,wheneverapplicable. ProductsmanufacturedanddistributedbyRELIABLEhavebeenprotectinglifeandpropertyforover80years,andareinstalledandservicedbythemost highlyqualified andreputablesprinklercontractorslocatedthroughouttheUnitedStates,Canadaandforeigncountries. TheReliableAutomaticSprinklerCo.,Inc. (800)431-1588SalesOffices (800)848-6051SalesFax (914)668-3470CorporateOffices www.reliablesprinkler.com InternetAddress Reliable...ForCompleteProtection Reliableoffersawideselectionofsprinklercomponents.Followingaresomeofthemany precision-madeReliableproductsthatguardlifeandpropertyfromfirearoundtheclock. •Automaticsprinklers •Flushautomaticsprinklers •Recessedautomaticsprinklers •Concealedautomaticsprinklers •Adjustableautomaticsprinklers •Dryautomaticsprinklers •Intermediatelevelsprinklers •Opensprinklers •Spraynozzles •Alarmvalves •Retardingchambers •Drypipevalves •Acceleratorsfordrypipevalves •Mechanicalsprinkleralarms •Electricalsprinkleralarmswitches •Waterflowdetectors •Delugevalves •Detectorcheckvalves •Checkvalves •Supertrolelectricalsystem •Sprinkleremergencycabinets •Sprinklerwrenches •Sprinklerescutcheonsandguards •Inspectorstestconnections •Sightdrains •Balldripsanddrumdrips •Controlvalveseals •Airmaintenancedevices •Aircompressors •Pressuregauges •Identificationsigns •Firedepartmentconnection Wrot Copper and Bronze Solder-Joint Pressure Fittings Dimensions of Soldered-Joint Ends (in inches) Male EndFemale EndInside Standard Diameter WaterOusideInsideWallof TubeDiameterLengthDiameterDepthThicknessFitting SizeAKFGTO Min.Max.Min.Min,Max.Min.Avg.Min. Engineering Data Elkhart Products Corporation 39 Working Pressures and Solder The table of maximum working pressures below must be understood to reflect what is generally considered as good engineering practice under reasonably constant and favorable conditions; i.e., pressures which are fairly steady, absence of particularly corrosive media, etc. Unusual conditions require increased safety factors and therefore, lower working pressures should be used. Rated Internal Working Pressures of Piping System Made of Copper Water Tube and Soldered Fittings ServicePOUNDS PER SQUARE INCH Solder UsedTemp.Water (a) in joints°FCopper Water Tube-Nominal Sizes 1⁄8" to 1"11⁄4" to 2"21⁄2" to 4"5" to 8" Incl.Incl.Incl.Incl. * 50-50 100200175150135 Tin-Lead (b)15015012510090 200100907570 25085755045 95-5 100500400300270 Tin-Antimony 150400350275250 (c) (d)200300250200180 250200175150135 Brazing AlloysTemperature and pressure ratings consistent with the Melting at ormaterials and procedures employed. above 1000°F. *The data given for 50% tin-50% lead applies also for the 40% tin-60% lead alloy. The values in this table are based on data in the National Bureau of Standards Publications, “Building Materials and Structures Reports BMS 58 and BMS 83.” (a) Including other noncorrosive liquids and gases (b)ASTM B32, Alloy Grade Sn 50 (c)ASTM B32, Alloy Grade Sb 5 (d)The Safe Drinking Water Act Amendment of 1986 prohibits the use in potable water. Systems of any solder having a lead content in excess of 2%. NOTE: The table at left is from data published by the Copper and Brass Research Association. Estimated Quantity of 50-50 Solder Required to Make 100 Joints Size in Inches 3/81/2 3/4 11 1/41 1/2 2 2 1/2 3 3 1/2 4 5 6 8 Quantity in Pounds .5.751.01.41.71.92.43.23.94.55.581532 1. The quantity of hard solder used is dependent in the skill of the operator, but for estimating purposes, 75% of the above figures may be used. 2. Two ounces of Solder Flux will be required for each pound of solder. 0.2520.2560.25 0.3770.3810.31 0.5020.5060.38 0.6270.6310.50 0.7520.7560.62 0.8770.8810.75 1.1281.1320.91 1.3781.3820.97 1.6281.6331.09 2.1282.1331.34 2.6282.6331.47 3.1283.1331.66 3.6283.6331.91 4.1284.1332.16 5.1285.1332.66 6.1286.1333.09 8.1288.1333.97 1/80.2480.2510.31 1/40.3730.3760.38 3/80.4970.5010.44 1/20.6220.6260.56 5/80.7470.7510.69 3/40.8720.8760.81 11.1221.1270.97 1 1/41.3721.3771.03 1 1/21.6211.6271.16 22.1212.1271.41 2 1/22.6212.6271.53 33.1213.1271.72 3 1/23.6213.6271.97 44.1214.1272.22 55.1215.1272.72 66.1216.1273.22 88.1198.1274.09 KT O A T G OF T T O A T G OF T T Male End Female End .0190.18 .0230.30 .0260.39 .0290.52 .0310.63 .0330.74 .0400.98 .0441.23 .0511.47 .0591.94 .0672.42 .0752.89 .0863.37 .0963.84 .1114.70 .1245.72 .1737.55 Engineering Data Fitting Material: Copper Alloy #122, Phosphorus Deoxidized-High Residual Phosphorus (DHP). Composition: 99% Copper; .015-.040% Phosphorus. Weld Material: Silicon Bronze. Meets specification American Welding Society (AWS) A5.7-91R and American Metals Society. Weld Specifications: Tensile Strength-Up to 58,000 PSI Yield Strength-Up to 25,000 PSI Elongation in 2"-53% to 55% Hardness-80 to 100 Brinell (500kg. Load) Temperature: Melt 1832°F, Flow 1931°F. Method of Joining: Electric Weld. Dimensions & Specifications: EPC Welded fittings are produced in accordance with specifications shown in Manufactures Standardization Society (MSS) SP-109 for wrought copper, and copper alloy solder-joint pressure fittings. Testing: Each fitting is individually tested with air under water. The burst pressure of EPC welded fittings exceeds the recommended working pressure of comparable diameter, annealed, straight, seamless ASTM B88- 96-Atype “L” copper water tube by a safety factor of 4:1 or more. Wrot Copper Fittings Large Diameter Welded Design 40 Elkhart Products Corporation †Slight variations from these weights must be expected in practice. Extracted from American National Standard Wrought Copper and Bronze Solder-Joint Drainage Fittings (ANSI B16.29) with permission of the publisher. The American Society of Mechanical Engineers, 345 East 47th St., New York, N.Y. Copper Water Tube-Standard Dimensions and Weights OutsideInside Diameter, InchesWall Thickness, Inches †Pounds per Linear Foot NominalDia., In. TubeTypesTypeTypeTypeType TypeTypeTypeType TypeTypeTypeType SizeK-L-M-KLMDWV KLMDWV KLMDWV InchesDWV 1/4.375.305.315--.035.030.025-.145.126.106- 3/8.500.402.430--.049.035.025-.269.198.145- 1/2.625.527.545--.049.040.028-.344.285.204- 5/8.750.652.666--.049.042.030-.418.362.263- 3/4.875.745.785--.065.045.032-.641.455.328- 11.125.9951.025--.065.050.035-.839.655.465- 1 1/41.3751.2451.2651.2911.295.065.055.042.0401.04.884.682.650 1 1/21.6251.4811.5051.5271.541.072.060.049.0421.361.14.940.809 22.1251.9591.9852.0092.041.083.070.058.0422.061.751.461.07 2 1/22.6252.4352.4652.495-.095.080.065-2.932.482.03- 33.1252.9072.9452.9813.035.109.090.072.0454.003.332.681.69 3 1/23.6253.3853.4253.459-.120.100.083-5.124.293.58- 44.1253.8573.9053.9354.009.134.110.095.0586.515.384.662.87 55.1254.8054.8754.9074.981.160.125.109.0729.677.616.664.43 66.1255.7415.8455.8815.959.192.140.122.08313.910.28.926.10 88.1257.5837.7257.785-.271.200.170-25.919.316.5- Wrot Copper Solder-Joint Drainage Fittings Dimensions of Soldered-Joint Ends (in inches) See Diagram Page 39 Male EndFemale EndInside MetalDiameter SizeOutside DiameterLengthInside DiameterDepthThicknessof Fitting AKFGTO Min.Max.Min.Min.Max.Min.Min.Min. 1 1/41.3721.3770.561.3781.3820.500.0401.29 1 1/21.6211.6270.621.6281.6330.560.0421.53 22.1212.1270.692.1282.1330.620.0422.01 33.1213.1270.813.1283.1330.751.0452.98 44.1214.1271.064.1284.1331.000.0583.93 36 ➀ ADAPTERS ELBOWS COUPLINGS FIGURE 5. Selected Pressure Fittings GENERAL NOTES: (a) Fittings are designated by size in the order: 1x2x3 (b) Fitting designs and drawings are for illustration only. 514 OFFSET C.P.V.C.-STEEL-COPPER HANGER SIZE MATERIAL FINISH PATENTNo.6,648,278. FUNCTION INSTALLATION WOOD #905 STEEL FEATURES #905 ORDERING 906 -3/4"thru2"pipe. -CarbonSteel. -Mil.Galvanized.. - -UseonC.P.V.C.,CopperorSteelpipe. Hangerandrestrainerontop,bottomorsideposition. -PerN.F.P.A13,13Rand13Don top,bottomorsideofbeam.Spacebypipetype. Snapoverpipethensqueezestrapbackallowingpipetoslidefreely. in: CPVCpipe-screw-nopre-drill. Copperpipe- Steelpipe-1/4x11/2lagscrew-nopre-drill. in: *11/2Offset. *3/4and1”pipesizehavecommoncenter-line. *Legdesignproducessuperiorstrength. *Offsetedgeeliminatesabrasion. *Requiredscrewhas5/16"hexhead-included -Part#andpipesize. #soldseparately. AFCON AFCON LISTINGS- EX4231,EX2551 906 FASTENERS #905 On3/8"woodwebuse#backingnuts.-seedrawing. Oncopper-insulatepipe. -ULListedperNFPA13 screw-nopre-drill. "" CPVCpipe-1/4"or#14TekScrew. Copperpipe-1/4"or#14TekScrew. Steelpipe-1/4"or#14TekScrew. " " Hanger,Restrainer andSupport Stabilize-Only Hanger/Restrainer Stabilize-Only 05/03 INDEX STEELSTEELSTEELSTEELSTEEL DRYWALLDRYWALLDRYWALLDRYWALLDRYWALL TM Threaded Rod Anchoring SystemThreaded Rod Anchoring SystemThreaded Rod Anchoring SystemThreaded Rod Anchoring SystemThreaded Rod Anchoring System forforforforfor 1/4”, 3/8” and 1/2” Threaded Rod1/4”, 3/8” and 1/2” Threaded Rod1/4”, 3/8” and 1/2” Threaded Rod1/4”, 3/8” and 1/2” Threaded Rod1/4”, 3/8” and 1/2” Threaded Rod SAMMYS 1349 W. Bryn Mawr Avenue • Itasca, IL 60143 www.sammysuperscrew.com • 800-BUILDEXBuilding Ideas That Work® W WOODWOODWOODWOODWOOD CONCRETECONCRETECONCRETECONCRETECONCRETE Approvals Rod Size Part #Item #Model Screw Descriptions Box Qty. Weight (per 125) Case Qty 1/4"800195720GST .7501/4 x 3/4255.93125 1/4"800295721GST 1001/4 x 1256.25125 1/4"800395722GST 2001/4 x 2258.13125 1/4"800495723GST 3001/4 x 3259.38125 1/4"800592524GST 6001/4 x 62511.25125 3/8"800695710GST .7501/4 x 3/4255.63125 3/8"800795711GST 101/4 x 1255.93125 3/8"800895712GST 201/4 x 2257.50125 3/8"800992527GST 25-3803/8 x 2-1/22511.56125 3/8"801095730GST 301/4 x 3258.75125 3/8"8011925403GST 401/4 x 42510.00125 3/8"801292514GST 601/4 x 62511.25125 1/2"80139258GST 21/4 X 2258.75125 1/2"80149256GST 2.5-3803/8 X 2-1/22512.50125 1/2"801592515GST 31/4 X 32513.13125 1/2"801692516GST 41/4 X 42513.25125 1/2"801792517GST 61/4 X 62513.69125 SAMMYS™ Steel Wood Concrete Vertical Mount Nut Driver Use #14 Nut Driver for Sammys and Swivel Head Part # 8113910 Item # 100 NFPA NFPA NFPA NFPA NFPA NFPA NFPA NFPA NFPA NFPA NFPA NFPA NFPA NFPA NFPA NFPA Approvals Rod Size Part #Item #Model Screw Descriptions Box Qty. Weight (per 125) Case Qty 1/4"805895764CST 2005/16 x 1-1/2258.44125 3/8"805995761CST 205/16 X 1-1/2257.81125 1/2"806092566CST 25/16 X 1-1/2258.75125 Approvals Rod Size Part #Item #Model Screw Descriptions Box Qty. Weight (per 125) Case Qty 1/4"802495750DSTR 1001/4-20 X 1257.81125 1/4"802595751DST 1001/4-14 X 1256.56125 1/4"802695752DST 1501/4-14 X 1-1/2256.88125 1/4"802795753DST 2001/4-14 X 2257.50125 1/4"802895754DST 2501/4-12 X 2-1/2258.44125 1/4"802995755DST 3001/4-14 X 3259.06125 1/4"803095756TEK 50012-24 X 1-1/2256.88125 3/8"803795729DSTR 1-1/2"12-24 X 1-1/2257.75125 3/8"803895730DSTR 1"1/4-20 X 1257.19125 3/8"803995731DSTR 5165/16-18 X 1-1/4257.06125 3/8"804095732DST 101/4-14 X 1255.94125 3/8"804195733DST 151/4-12 X 1-1/2256.56125 3/8"804295734DST 201/4-14 X 2256.88125 3/8"804395735DST 251/4-14 X 2-1/2257.81125 3/8"804495736DST 301/4-14 X 3258.44125 3/8"804595737DST 5165/16-18 X 1-1/4257.50125 3/8"804695738TEK 5012-24 X 1-1/2256.88125 1/2"8031925601DST 2.01/4-14 X 2258.44125 1/2"80329251113DST 2.51/4-14 X 2-1/2259.06125 1/2"8033925422DSTR 1.01/4-20 X 1256.25125 1/2"803492528DSTR 5.165/16-18 X 1-1/42510.00125 1/2"8035925443DST 5.165/16-18 X 1-1/4258.44125 1/2"80369255TEK 5.012-24 X 1-1/2257.50125 SIDEWINDERS™ Steel Concrete Sammy Swivel Head™ NEW! NEW! NEW! NEW! NEW! NEW! NEW! NEW! NEW! NEW! * Use with 3/8” Rod U.S. Patent No. 6,443,680 • 17° deflection from vertical • Accommodates up to 3-1/2 x 12 pitch roof • Also available in stainless steel • Use #14 Nut Driver (black) Wood Nut Driver Use #14SW Nut Driver for Sidewinders and 1/2” Rod Sammys Part # 8114910 Item # 101 NFPA NFPA NFPA NFPA NFPA NFPA NFPA NFPA NFPA NFPA NFPA • Most Items Available in Stainless Steel SAMMY X-PRESS™Patent Pending Uninstalled Approvals Rod Size Part #Item #Model Screw Descriptions Box Qty. Weight (per 125) Case Qty 1/4"80189574016SWG 1001/4 X 1259.38125 1/4"8019957300SWG 2001/4 X 22510.00125 3/8"802095718SWG 101/4 X 1257.50125 3/8"802195719SWG 201/4 X 2258.75125 3/8"802292526SWG 25-3803/8 X 2-1/22512.81125 3/8"802392525SWG 301/4 X 32510.63125 Approvals Rod Size Part #Item #Model Screw Descriptions Box Qty. Weight (per 125) Case Qty 3/8"805095739SWD 101/4-14 X 1257.50125 3/8"805195740SWD 151/4-14 X 1-1/2259.38125 3/8"805295741SWD 201/4-14 X 2258.13125 3/8"805395742SWD 5165/16-18 X 1-1/4258.75125 3/8"805495746SWDR 1-1/2"1/4-20 X 1-1/2259.06125 3/8"805595743SWDR 1"1/4-20 X 1-1/2258.75125 3/8"805695744SWDR 5165/16-18 X 1-1/42510.31125 3/8"805795745SWT 1512-24 X 1-1/2257.81125 Installed TM Hang Threaded R o d D i r e c t l y from Thin Gau g e M e t a l Deck & Purlin Horizontal Mount ApprovalsPart #Item #Model Screw Descriptions Box Qty. Weight (per 125) Case Qty 81399574702SH-GST 201/4 x 2259.38125 81409574703SH-GST 22SS1/4 x 2259.38125 81419574704SH-GST 301/4 x 32510.94125 81429574705SH-GST 30SS1/4 x 32510.94125 81379574700SH-DSTR 11/4-20 x 1259.38125 81389574701SH-DSTR 1 - SS1/4-20 x 1259.38125 WOOD STEEL NFPA NFPA NFPA NFPA NFPA NFPA NFPA NFPA Approvals Rod Size Part #Item #Model Screw Descriptions Box Qty. Weight (per 125) Case Qty 1/4"80629571900SWC 2005/16 X 1-1/2259.38125 3/8"806195765SWC 205/16 X 1-1/2259.38125 Approvals Steel Ga.Part #Item #Model Box Qty. Weight (per 125) Case Qty. 22-208150922500XP 202510.3125 18-168153922503XP 352510.3125 8151910501XPIT11.021 8152910502XPDB10.141 Sammy X-Press It Installation Tool 25/64" Drill Bit Screw Descriptions 1/4-20 x 1-1/8 Sammy X-Press 20 (Kit includes: Sleeve, Bit Receiver, Hex Wrench, and 25/64" Drill Bit) STEEL 1/4-20 x 1-1/8 Sammy X-Press 35 CoCoCoCoConnnnncrete/Woocrete/Woocrete/Woocrete/Woocrete/WoodddddSpoSpoSpoSpoSpottttt-Rite Le-Rite Le-Rite Le-Rite Le-Rite Le velvelvelvelvel™™™™™ • Snap nut anywhere onto threaded rod • Non-corrosive and non-conductive • Supports cable, pipe, or conduit • Multiple hangers per rod • Plenum Rated snapsnapsnapsnapsnap hhhhhooooooooookkkkk hanhanhanhanhanggggg The Pole Tool and Universal Socket Kit provide easy and safe installation for: • Sammys • Threaded rod • Pencil rod • Ceiling screws • Jack chain • Wire • Screws Use for installing SAMMYS™ & Sidewinders™ into concrete or extemely hard wood. Provides both a torpedo level and a gunner nipple in one handy tool. Sammys™, Sammy Super Screw®, Speedy Pole Tool™, Sammy Swivel Head™,Sammy X-Press™, Sammy X-Press IT™, Sidewinders™, Sammy Saddle™,Spot-Rite Level™, Teks® and Building Ideas That Work® are trademarks of ITW Buildex and Illinois Tool Works, Inc. Viper™ and Ladd™ are trademarks of Illinois Tool Works, Inc. ©2003 Illinois Tool Works, Inc. Product Report No. 030102 TIME SAVERS Also has 1/2”, 3/4”, and 1” threaded ends for multiple use. 4016 &&&&& Have the right tools for the job! SaSaSaSaSa mmmmmmmmmmy Sady Sady Sady Sady Saddddddlelelelele™™™™™ Holds up to 35 pieces of Category 5 cabling! * NEW!NEW!NEW!NEW!NEW!NEW!NEW!NEW!NEW!NEW! Each box c o n t a i n s Snap Nuts f o r b o t h 3/8” & 1 / 4 ” Threaded R o d Part #Item #Model 8129910139UNIVERSAL INSTALLATION KIT Stud Plug for Viper or Ladd Powder Actuated Attachment Adaptor Plug Socket Driver for Samy Super Screws Socket Driver for Ceiling Wire Screws Socket Driver for 1/4" Standard Nut Drivers Part #Item #Description 8123910130 SPEEDY POLE TOOL 6' (3' -6') 8124910131 SPEEDY POLE TOOL 12' (4' - 12') 8125910132 SPEEDY POLE TOOL 18' (6' - 18') 8126910133 SPEEDY POLE TOOL 24' (8' - 24') 8127910138SAMMY SOCKET DRIVER 81289103004CEILING WIRE SOCKET DRIVER Part #Item #ModelDescription 81499575000CZ-20001/4" and 3/8" SAMMY SADDLE Part #Item #Description 8130910134SPOT RITE LEVEL Cable Manage m e n t in a SNAP! U.S. Patent No. 6,146,076 speedy Pospeedy Pospeedy Pospeedy Pospeedy Pole Tle Tle Tle Tle Toooooooooolllll™™™™™ Socket Socket Socket Socket Socket Part #Item #Description 81229103009CONCRETE INSTALLATION KIT Item #110-SL 250 - Sleeve Item #105-HEX 250 - Bit Receiver (1/4") Item #100-#14 Nut Driver Item #101-#14 SW Nut Driver Item #107-#250 - Bit (1/4") Item #109-SDS 250 Bit (1/4") Item #114-7/32 Wood Bit InstInstInstInstInstallallallallall aaaaatititititiooooon Kitn Kitn Kitn Kitn Kit 650 ALLTHREADEDROD10'-0'LENGTHS SIZE MATERIAL FINISH ORDERING -1/4thru11/2inchrodin10'-0"lengths. -CarbonSteel. -Plain,Electro-Galvanizedand StainlessSteel. -Part#,roddiameterandfinish. 1/4 3/8 1/2 5/8 3/4 7/8 1 11/4 11/2 240 610 1130 1810 2710 3770 4960 8000 11630 215 540 1010 1610 2420 3360 4420 7140 10370 NOTE;maximumTemperature:750°F ROD SIZE MAX.REC.LOADLBS. FORSERVICETEMP. 650°F750°F 2/00 302 RINGHANGER SIZE- MATERIAL-StainlessSteel-(Type304) CONFORMSWITH: MAXIMUMTEMPERATURE FUNCTION- INSTALLATION FEATURES ORDERING- 1/2thru8inchpipe. FederalSpecificationWW-H-171(Type10, ManufacturersStandardizationSocietyANSI/MSS-SP-58(Type10). -650F. Pipehangercomponentforuseonsteelor copperpiping.ForusewithCPVC-consultfactory. -P - *Stainlesssteelswivelnut. *Customfitswivelnutforbetterretentioninringbody. Part#,pipesize. Note:OnCopper-Insulatepipe. 0 erNFPA-13,13Rand13D. *Sizedandlistedexclusivelyforusewith#310SurgeRestrainer. 08/03 PIPE 1/2 3/4 1 11/4 11/2 2 21/2 3 31/2 4 5 6 8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 1/2 1/2 1/2 400 400 400 400 400 400 600 600 600 1000 1250 1250 1250 10 10 10 10 10 10 10 10 10 10 12 12 12 *OrderPart#300m LOADLBS. METRIC* ROD MAXREC.IMPERIAL PIPE ROD 20 25 32 40 50 65 80 100 125 150 200 Note:1/2"RingHangernot<FM>approved o The AGF Manufacturing Inc. Model 1000 TESTANDRAIN Provides Both The Test Function And The Express Drain Function For A Wet Fire Sprinkler System. o The Model 1000 Complies With All Requirements Of NFPA-13, NFPA-13R, And NFPA-13D. o The Model 1000 TESTANDRAIN Is A Single Handle Ball Valve That Is Light Weight And Compact, Includes A Tamper Resistant Test Orifice, Integral Tamper Resistant Sight Glasses, And Is 300 PSI Rated. o Available In A Full Range Of Sizes From 3/4" To 2" NPT & BSPT, With All Specifiable Orifice Sizes 3/8", 7/16", 1/2", 17/32", 5/8" (ELO), & 3/4" (ESFR). o The Orifice Size Is Noted On The Indicator Plate And The Valve Is Tapped For A Pressure Gauge. o Locking Kit Available Which Provides Superior Vandal Resistance And Prevents Unintentional Alarm Activation. MODEL 1000 10/00 C h e c k O u t O u r New AutoCAD Site! *Available on 1 1/4" to 2" size units only. **3/4" UL Listed only. APPROVALS: o UL and ULC Listed o FM Approved except 3/4" o NYC-BSA NO. 720-87-SM o CA. State Fire Marshall 5 1/16"128mm 3/4" 1" 1 1/4" 1 1/2" 2" 1 1/2"37.58mm 2 3/16"55.65mm 3 5/8"93.23mm 3 3/8"85.88mm 1 13/16"45.30mm 4 9/16"117.12mm 6 3/8"162.42mm 5 1/16"128mm 1 1/2"37.58mm 2 3/16"55.65mm 3 5/8"93.23mm 3 3/8"85.88mm 1 13/16"45.30mm 4 9/16"117.12mm 6 3/8"162.42mm 5 7/16"137.70mm 1 11/16"42.70mm 2 9/16"65.36mm 4 1/4"108.36mm 3 5/16"82.84mm 1 15/16"50.89mm 5 9/16"141.39mm 5 1/2"192.28mm 6 7/16"163.38mm 1 13/16"45.50mm 3 1/4"81.50mm 5 1/16"127mm 3 7/8"99.18mm 2 5/8"66.97mm 8 1/4"206.63mm 10 7/8"273.60mm 6 7/16"163.38mm 1 13/16"45.50mm 3 1/4"81.50mm 5 1/16"127mm 3 7/8"99.18mm 2 5/8"66.97mm 8 1/4"206.63mm 10 7/8"273.60mm AGF MANUFACTURING INC. 100 Quaker Lane Malvern, PA 19355 USA Telephone: (610) 240-4900 Fax: (610) 240-4906 www.testandrain.com BB-SC 100 &S02 BBSC100_rev0.CDR MILWAUKEEVALVE 1 2-"/" Approvedby:NYCBoardofStds.&Appeals, Cal.#996-81-SM(175psi) 720-83-SA(350&500psi) D Theinformationpresentedonthissheetiscorrectatthetimeofpublication.Milwaukee Valvereservestherighttochangedesign,and/ormaterialspecificationswithoutnotice. Forthemostcurrentinformationaccess.www.milwaukeevalve.com 1 2- BRONZEBUTTERFLYVALVE ONE-PIECE,FULL-PORT 175PSI THREADEDENDS C US APPROVED MATERIALSLIST butterball SLOWCLOSE 1 2 3 4 5 6 PertainstoBB-SC100only. PertainstoBB-SCS02only. AREDIMENSIONSUSINGSCHEDULE40 PIPE AREDIMENSIONSUSINGSCHEDULE80 PIPE ISFLOWRESISTANCEEXPRESSEDIN EQUIVALENTLENGTHOFSCHEDULE40 PIPE ISTHEWRENCHMAKE-UPLENGTH M-40 M-80 N-40 W FEATURES Slowopeningandclosing -Signalsdiscmovement -FactoryorFieldinstallation -10Amp/115VAC-60Hz -0.5Amp/28VDC Quarterturnoperation WaterHammerelimination Optionalinternaltamperswitch (Indooruseonly). GroovedEndsAvailablein Sizes2”and2-1/2” “M" B “L" BUTTERFLYVALVE 76G2 OPEN R LISTED M L “K” (MAX ENTRY) “C"C 4-1/2” BB-SC100 Sizes1”,1-1/4”,1-1/2”,2”,2-1/2” W A 4-1/2” “C"C BUTTERFLYVALVE 76G2 OPEN R LISTED W A J D BB-SCS02 (IncludesSwitch) DIMENSIONS ALLDIMENSIONS-INCHES 2-1/2” 4.13 3.82 3.19 3.50 4.66 1.18 1.29 2.47 2.32 10.00 1.75 DIM A B C D J K L M-40 M-80 N-40 W 1 2 3 4 5 6 1” 2.13 3.16 1.56 1.72 4.16 .66 .83 1.10 .96 2.25 1.13 1-1/4” 2.63 3.31 1.94 2.11 4.16 .73 .90 1.38 1.28 2.00 1.25 1-1/2” 2.88 3.41 2.19 2.38 4.51 .73 .10 1.61 1.50 2.50 1.41 2” 3.25 3.63 2.75 3.07 4.76 .79 1.41 2.07 1.94 2.25 1.69 ValveSize 5 4 3 6 1 2 7 ITEMPARTMATERIALSASTMSPEC. 1 IndicatorIronF0008P 2 Housing 3 Body 4 HandleBrass ASTMB176UNS C85800 5 Disk StainlessSteel ASTMA276, Type304 6 DiskSeal EPDM 7 SwitchHousing (BB-SCS02)Aluminum Bronze ASTM584UNS C8440 PRINTED IN USA MKT. #8800003 - REV AA MFG. #5400802 - 11/02 VSR-SF VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD FOR SMALL PIPE PAGE 1 OF 2 UL, ULC, CSFM Listed and NYMEA Accepted, CE Marked Service Pressure: Up to 250 PSI (17,2 BAR) Minimum Flow Rate for Alarm: 8-10 GPM (30-38 LPM) Maximum Surge: 18 FPS (5,5 m/s) Enclosure:Die-cast, red enamel finish Cover held in place with tamper resistant screws Contact Ratings:Two sets of SPDT (Form C) 15.0 Amps at 125/250 VAC 2.0 Amps at 30 VDC Conduit Entrances: Two knockouts provided for 1/2" conduit. Usage:Listed plastic, copper and schedule 40 iron pipe. Fits pipe sizes - 1" (25mm), 1 1/4" (32mm), 1 1/2" (38mm) and 2" (50mm) Note: 12 paddles are furnished with each unit, one for each pipe size of threaded and sweat TEE, one for 1" (25mm) CPVC, one for 1" (25mm) CPVC (Central), one for 1 1/2" (38mm) polybutylene and one for 1 1/2" (38mm) threaded (Japan). (CTS-Copper tubing size) Environmental Specifications: •Suitable for indoor or outdoor use with factory installed gasket and die-cast housing. •NEMA 4/IP55 rated enclosure - use with appropriate conduit fitting. •Temperature range: 40° F to 120° F, 4,5° C to 49° C) Caution:This device is not intended for applications in explosive environments. Service Use: Automatic SprinklerNFPA-13 One or two family dwellingNFPA-13D Residential occupancy up to four storiesNFPA-13R National Fire Alarm CodeNFPA-72 Optional: Cover Tamper Switch Kit, Stock No. 0090018 Stock No. 1113000 U.S. Pat. No. 3921989, Canadian Pat. No. 1009680 Other Patents Pending The Model VSR-SF is a vane type waterflow switch for use on wet sprinkler systems that use 1" (25mm), 1 1/4" (32mm), 1 1/2" (38mm) or 2" (50mm) pipe size. The unit may also be used as a sectional waterflow detector on large systems. The unit contains two single pole double throw snap action switches and an adjustable, instantly recycling pneumatic re- tard. The switches are actuated when a flow of 8-10 gallons per minute (30-38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. INSTALLATION: These devices may be mounted in horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be installed within 6" (15cm) of a valve, drain or fitting which changes the direction of the waterflow. Select the proper paddle for the pipe size and type of TEE used see Fig. 1 for instructions on changing paddle. The unit has a 1" NPT bushing for threading into a non-corrosive TEE. See Fig. 2 for proper TEE size, type and installation. Use no more than three wraps of teflon tape. Screw the device into the TEE fitting as shown in Fig. 2. Care must be taken to properly orient the device for the direction of waterflow. The vane must not rub the inside of the TEE or bind in any way. The stem should move freely when operated by hand. The device can also be used in copper or plastic pipe installa- tions with the proper adapters so that the specified TEE fitting may be installed on the pipe run. INSPECTION AND TESTING: Check the operation of the unit by opening the inspector’s test valve at the end of the sprinkler line or the drain and test connection, if an inspector’s test valve is not provided. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR-SF is not recommended or advisable The frequency of the inspection and testing and its associated protective monitoring system should be in accordance with the applicable NFPA Codes and Standards and/or authority having jurisdiction (manufacturer recommends quarterly or more fre- quently). Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MKT. #8800003 - REV AA MFG. #5400802 - 11/02 VSR-SF VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD FOR SMALL PIPE PAGE 2 OF 2 CAUTION: An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. FIG. 1 Important: There are 12 paddles fur- nished with each unit. One for each size of threaded, sweat or plastic TEE as described in Fig. 2. These paddles have raised lettering that shows the pipe size and type of TEE that they are to be used with. The proper paddle must be used. The paddle must be properly attached (see drawing) and the screw that holds the pad- dle must be securely tight- ened. FIG. 2 NOTES: 1.The model VSR-SF has two switches, one can be used to operate a central station, proprietary or remote signal- ing unit, while the other is used to operate a local au- dible or visual annunciator. 2.For supervised circuits see “Switch Terminal Connec- tions” drawing and caution note (Fig. 3). FIG. 4 TYPICAL ELECTRICAL CONNECTIONS Retard Adjustment: To change time, turn knob (either direction) for desired time delay. Use the minimum amount of retard necessary to prevent false alarms. A “B” setting is usually adequate for this. Factory set at “B”. FIG. 3 SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL FIG. 5 To remove knockouts: Place screwdriver at edge of knock- outs, not in the center. APPLICATION WARNING! Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times, waterflow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Screw the device into the tee fitting as shown. Care must be taken to properly orient the device for the direction of waterflow. On sweat tees, no threaded bushings, inserts, or adapters are permitted, unless they comply with the dimensions listed in the chart below. Important - The depth to the inside bottom of the tee should have the following dimensions: Warning: Do not use more than three wraps of teflon tape. Shown with optional Cover Tamper Switch Kit.