Loading...
HomeMy WebLinkAboutB12-0416NOTE: THIS PERM/T MUST BE POSTED ON JOBSITE AT ALL TIMES .• �o�a�v�rr. . Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B12-0416 Job Address: 2801 BASINGDALE BLVD VAIL Location......: CAMELOT TOWNHOMES UNIT 8 Parcel No....: 210314311008 OWNER NOVICK, WALTER R. AND ALEXAN 09/06/2012 8299 E OTERO CIRCLE CENTENNIAL CO 80112 APPLICANT EDGE CONSULTING GROUP INC 09/06/2012 CHIP NOVICK 8299 E OTERO CIRCLE CENTENNIAL CO 80112 License: C000003620 Project #: PRJ12-0517 Appl ied..... : 09/06/2012 Iss ued. . . : 09/28/2012 Phone: 913-908-5403 Phone: 913-908-5403 CONTRACTOR EDGE CONSULTING GROUP INC 09/06/2012 Phone: 913-908-5403 CHIP NOVICK 8299 E OTERO CIRCLE CENTENNIAL CO 80112 License: C000003620 Description: REPLACE EXISTING PATIO DOORS AND BEDROOM WINDOWS. Occupancy: Type Construction: Valuation: $45,000.00 ...........,,,.......,..x ................................................,..>.,..,.,. FEE SUMMARY ......,,.,........�,.�.,............,.,.,...,...............,,,,...,......,........ Building Permit -----------> $613.45 Bldg Plan Check ----------> $398.74 Use Tax Fee----------------------> $700.00 Electrical Permit ---------> $172.50 Elec Plan Check -----------> $112.13 Restuarant Plan Review--------> $0.00 Mechanical Permit ------> $160.00 Mech Plan Check ---------> $40.00 Additional Fees--------------------> $200.00 Plumbing Permit --------> $30.00 Plmb Plan Check ---------> $7.50 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $20.00 TOTAL PERMIT FEES--------------> $2,564.32 Payments-------------------------------> $2,564.32 BALANCE DUE------------------------> $0.00 ..................�,�....a..=..,,.+_...................�..................�...+.....:_........,..,._.....�..........................,......�.....»....x.............>.._.....+...,....... DECLARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM. combination permit_012811 �� � ' ' ....,.....> ..............»..,...,,.,,..........,.,..........,............,,......,....,.,..,,...............,....,.,...,.....,,,......,...,,...........,.....,..................,...., CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B12-0416 Address: 2801 BASINGDALE BLVD VAIL Owner: NOVICK, WALTER R. AND ALEXANDRA S H NOVICK Location: CAMELOT TOWNHOMES UNIT 8 ............................... �.,.........,...,.................,..........,......,....,.......»,......»,,,,,,.............,,........,......,................,.,....,................ combination permit_012811 ♦ � T��N �}F VA� ' .,**.********************....*******,.*****************..***.*.****************.,.***********,�,************************,.,**********,******.�****,**,,,.... REQUIRED INSPECTIONS AND STATUSES Permit #: B12-0416 Address: 2801 BASINGDALE BLVD VAIL Owner: NOVICK, WALTER R. AND ALEXANDRA S H NOVICK Location: CAMELOT TOWNHOMES UNIT 8 «********««**««*****,.****«**�****,�.«*„*********«*««*««***,.*******************«�*****«*******,,,««*******�**«******„**********�.*«**�««**�«**««******** Item: 00120 ELEC-Rough 10/09/2012 By: sgremmer Action: AP Item: 00200 MECH-Rough 10/09/2012 By: sgremmer Action: AP Item: 00230 PLMB-Rough/Water 10/09/2012 By: sgremmer Action: AP Item: 00240 PLMB-Gas Piping 10/09/2012 By: sgremmer Action: AP Item: 00310 MECH-Heating Item: 00060 BLDG-Sheetrock Nail Item: 00190 ELEC-Final Item: 00290 PLMB-Final Item: 00390 MECH-Final Item: 00090 BLDG-Final combination permit_012811 o 'CI 1 01-10-2013 Inspection Request Reporting Page 6 4:01 pm Vail, CO - City Of Requested Inspect Date: Friday,January 11 2013 Site Address: 2801 BASINGDALE BLVD VAIL CAMELOT TOWNHOMES UNIT 8 A/P/D Information Activity B12-0416 Type: COMBO Sub Type AMF Status: ISSUED Const Type Occupancy: Use Insp Area Owner NOVICK,WALTER R.AND ALEXANDRA S H Phone 913-908-5403 NOVICK Contractor: EDGE CONSULTING GROUP INC Phone: 913-908-5403 Description: REPLACE EXISTING PATIO DOORS AND BEDROOM WINDOWS. Requested Inspection(s) Item: 90 BLDG-Final Requested Time: 02:30 PM Requestor: EDGE CONSULTING GROUP INC Phone: 913-908-5403 Comments 913-908-5403 Assigned To JMONDRAGON Entered By: JMONDRAGON K Action Time Exp: Item: 190 ELEC-Final Requested Time: 01:00 PM Requestor: EDGE CONSULTING GROUP INC Phone: 913-908-5403 Comments 913-908-5403 Assigned To JMONDRAGO Entered By: JMONDRAGON K Action Time Exp: Item: 290 PLMB-Final Requested Time: 01:30 PM Requestor: EDGE CONSULTING GROUP INC Phone: 913-908-5403 Comments 913-908-5403 Assigned To JMONDRAGON ► Entered By: JMONDRAGON K Action L'I � Time Exp: Item: 390 MECH-Final Requested Time: 02:00 PM Requestor: EDGE CONSULTING G UP INC Phone: 913-908-5403 Comments 913-908-5403 Assigned To JMONDRAGON Entered By JMONDRAGON K Action Time Exp: r 1 � V efiC) , wd C9c} Inspection History , �/ Item: 120 ELEC-Rough **Approved** 10/09/12 Inspector: sgremmer Action: AP APPROVED Comment: Item: 200 MECH-Rough *'Approved** itair9 10/09/12- Inspector: sgremmer Action: AP APPROVED Comment: Item: 230 PLMB-Rough/Water **Approved** 10/09/12 Inspector: sgremmer Action: AP APPROVED Comment: . /)/ Item: 240 PLMB-Gas Piping **Approved" �✓J 10/09/12 Inspector: sgremmer Action: AP APPROVED Comment: el Item: 310 MECH-Heating **Approved** REPT131 Run Id: 1504 6 ProjedTitle �m �C'Ci� �=%_ K L P �2�.�� �,� Work Descrip._,4� =� �Ji��e��..� � Date��'r G..�� , � Des. By: � .-•''r Chk. By: � CONSULTING ENGINEERS P9-��of � Project No. �� — 32� �S ` _ �1 � - . _ � ' '� ' �'s.�p' _ � � .`�.y �'�`i�� �:��j _. �..._. . . ._ �... . .. :..... . ... _.. ... � 5'.�` � `..� rl �. 4,. 4.,�� o.:. -�N g111�+� : - i _ �. � .... .� .._....e . . . ._... .. . .....- .. .... . ;... _... . . :.A � j 1 1 £�� _� _ . � ;._. , _ ,� - - �:...... .�::... _._...�_. _� _ _.` _ ��� t � _ . - �����;.a 1:�-� _ �� � — ... . ,. p --— — _ _ -- . . .. . . _-�f ��.,. � . . _.. .... ., . ... .. �'.. ., . f .:-. ��r . ... .. ....� ._ , .,.. ,... ���.. �..... «-, �.... ..... .. .. . . :- . �¢� . ,�._ ' . .. W ...+.��,' . . ._ : - . ... .. . . . .. .. � . _ . : .... �: . . _ ... _... , .. __ _ . . . . . ... _ _. _ . .._ . _ . ..... . . �.. . �.. . ��� = ' • � - : r � ..._ . .__ ..�. __- _.. . ��� � . :� .. � .. : � :.._ _ . ... . ._... _ _. .: -.� .:._.... —:. . ....... . . . ..... . : _.. , s . . . : . _ . �:_.. . ...,.�' ....�... � . � . � �_ . .... . . _..._ _ � .:.....,...._. :.... . .. �. ... .. . .. .. ..... ... . . ... . _. . . y-. . . . .. .. ._ .... � � -... . - . . _. _. ._ _. . ... .. : - � . � ,.�.:......w ....v-�.:_.... :...v� -.. ,.,... .. . . . . . ... ... ..m. _..o.. � ,. ...:. ._�.. . _:., _ .. , . ,.. .. �x���:�-��Jfy m� �_�._ ___, _ . _ __ ;_ _�. . __ . __ _ . _ _ _ _ �.. _ _ _. _ � _ _ _ � _. _ __ _ ��. �jEI,U :r�tj' 1�'►qLC, ��' � . -� _ _ _ ( � _ _ _ - �2 �Y'�.�' �l�'��!' _ _- � �� � y� _._ �_ _ . _ , _ .._... , , f .. . � � .. . .. . .. . '. s . . � � . _P-"- ����/.�„` Y /l�" :�.�'L.�S _ ; - ; .. , _ . . ... __ _ _ . .:- - -... _. ..._ �._. _ �. , _. _ _ . _ . �__ ... . � � _ '_ __ _ ��. � { ` --_.:-- ... _ _ ,. _._ .__. .: :. - -- - - i,' �,,.-'rJ :2y _ ,C�•�'� .9`,� � -_ __ ' _ _ _ __,.: . � `��' � : _ : _ ' _ � � q� � {��::=�'x� -7-����= . . {� � __ _ � � � � __.� . _, - -- - - , � _ : �� - __ _ -- _ - - - - - - �- - _- � - -- { _, _ E . , . � : . : . j . :.' , . , `�- �.�' �� . . . . r : : : . ;. , : , " � . �. �. .. , . �� 4.... .... -:_ � .. ., ... _ � . .. . .._ �_.. � .___ '."__ '- f._ . - ... _ -: � - �Y =-.. _.-� � . �- � fn� +t�7ts �. t ' \SlN1t�1 � � �� �\�Q. F ! � ���s _ _.,_.. .�. .._ ..._� ;_,.. �� � � � /r � _ . � _:. _�� Q ; F _ . ._ � _ i � 1 q�.' i ' __ - � �F> _ _. , • ; . _ �. _, �; i �x: L.c _ ,� _ -_ � _ ., __ � - ;, � ' � ; a u'' � _ # :; _. � �;�w ! � �. ... _ ` _ "_ � _ ,_ , � 1 __ �_ _ . _ . _ . :�,G'' �` - � ___.. . � � . , ' � � � r C `�,\'�� ; ..__. .1. __. _ �, ...,,:_ _.!p:_ _ �._..:.,... ....,___ . . ,_,. :I !;y: � "� ..._ ,�_... ..._ .: .��.__. � .. .��...;} ._{. ,._3_... .. ' _� � __. � .� /�� /!�f H{��`4»�\� - � .' �_... _.. '...�.. � ; . � ; __. _.. � . _ .,. . . y _. . .�. _.. . ��. _ . _ _ . .�. . ! .; __ � __ _ . _ _ _. i _ _ � , _ � . .� __. _ .._ - : - y� , _ _ _ ' � � �.� �'�..I�J �',�rQ'� _:... :_. ; _ _ __ ' __ , �°�!y'�_ �°�'ja` : _ _ � � � 0 <- � � � � � � � � � �r `r. � � � N „s-, i ° � � „Z/6 £-,L 6 „9—,6 x,A—�8 � �� � �� „Z/� GG-,£G % ,'tj � � � � ; � _.,� � i � � � � � � `�.. � . s � � �.• � O -� O LL `� Z a— � � � LL ��RaC ' Q � � � M �OW m�nQ. � w � _ 0 _ Z Q :'� � N N � r�.,01 W�Qo �a�mo ��o�o �=��,v E �YMa �� � m>�o� a�'� .«� � o �v»aa �� �o 00 a '"'' m '� cw,� w � W� '� � e-1 A M v� � �z��' a�00� V � O � a 0 o¢Q z c� > a l � � �,�^'�y�v � , . �l.ikLfE�: ..Y .•5�;�, - +°��:.�:����.��1t �l ��� ���� *��£ ��.,,.. . - .. !. - s �at�a. __���, J � r� �y ` yvti.,�, _ _ ,. �� va�r i �� � � �r ` '',������ ' �,� SEP 2 � �0�1 , TOWN O� VAI�, � � � � � 1 � Department of Community Development 75 South Frontage Road TOWN OF VAIL' � va�i, co s�ss� Tel: 970.479.2128 www.vailgov.com Development Review Coordinator TRANSMITTAL FORM Use this form when submitting additional information for planning applications or building permits. This form is also used for requesting a revision to building permits. A two hour minimum building review fee of $110 will be charged upon reissuance of the permit. Application/Permit #(s) i�formation applies to: A ' n: • Revisions 612 - 0416 Response to Correction Letter �attached copy of correction letter n�, '�� O� `� ;� � p Q Deferred Submittal �" , �� � Other Project Street Address: 2801 Basingdale Blvd 8 (Number) (Street) (Suite #) Building/Complex Name: Camelot Townhomes Applicant Information (architect, contractor, owner/owner's rep) Contact Name: Chip NoviCk Address: 8299 E Otero Clrcle �;ty Centennial State: CO Z;p; 80112 Contact Name: Chip NoviCk Contact Phone: 913.908.5403 Contact E-Mai�: chip.novick@gmail.com I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is corcect. 1 agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review ap- proved, International Building and Residential Codes and other Xrdinar�es of the�own �pplicable� L `�� vv OwnedOwner's Representative Signature (Required) For Office Use Only: Fee Paid: Received From: Cash Check # CC: �sa / MC Last 4 CC # exp. date: Authorizadon # Description of TransmittaU List of Changes, Items Attached: Adding new window to the east wall second story of the property (use additional sheet if necessary) Building Permits: Revised ADDITIONAL Valuations (Labor 8� Materials) (DO NOT include original valuation) Building: Plumbing: Electrical: $1500 Mechanical: $ Total: $1500 Date Received: D������[�bC� s�P 2 8 zo�z I TO—�_F VAIL � , ..+� Town ofVail—Building PermitAmendment Property: 2801 Basingdale Blvd Va i I, CO 81657 Pa rce I 2103 143 11-008 Permit # B12-0416 �'oar� � �ta�� ����� ���� Owners Chip and Sande Novick 8299 E Otero Cir Centennial, CO 80112 chip.novick(«�gmail.com sande.novickC��mail.com � � 4 � � ■ . � Conditional Approval 9/27/12 �.r, 3�. �� ':- ,�.: � ��i�v r µ �, '� uu� mm'tyoue w��u. \'�il. CV tlalT Gamelot Tov�lnhouse Association s����,n�r �.�. �uiz Chip Novick 28UI BuiingdalaBh�d. Unh S b'�il, CO 81657 Iknr Chip: Pursuant to Arucic lY, section I nf the Camebt Townhouse As�ocialiaa Declaratio� the Arch�tectural Control Cammipce has rev�cwed a prchminary plan 10 sdd an addiponsl cx�erior aindow on �he a� fsring side of Unit k R. Ai th�x ume, thc canm�dee hw gantod "candrtional" approval for thc proposed addiuon of this xinciuw� to thc curtrnt construction pro}ect Thu lata should �en�c u a w�citten amcndmrnt to the prc��ausly s�gned "loint Prorcrty Owncts 1Yntten Approval Lettcr" signod end submitted to the Toun of \�ail on or abau19,�5�2012. As dictatnd 6}� �h� aforcmentioned xcpon of the Associotions Declaratian; liml rvrinrn design a�ro���l oC ihe window dnails, uicludmg �izing, plecemrnt, trim, matmals, etc, will 6c rcquurd pnor to thc commencemrnt of any exte�or alteratlona. It should be undcrstood the� that Comminec mtrnds to cvaluate ihe appmpriatenn� of such dela�Lc in rclatwn to the c+oamctic a�cal oCthe east rnd of' bwlding as a u�hole, and w�ll likeh� rcqucrc �ddiuonal iaformouon and da�vmentation from you in thc tuturc to ficilnate fina! approval. T4is conditianal oppror•al oC�pp�{.sdauld not be intctprctcd u a wan•e of any ofU►e Cametot Townrwusc A.uacutioa►s rig6ts of teriew aad or approval as dictatcd in lhcir goveming documentc. Thank you for pour commiunrnt w�rn�ove your unit 1ti'e wirh you the bnt of luck on your projec�. Su�cady, Micfud C. Callas Prcsidcat ('am�lnt Trw�nhrnu� A�enriatinn 2801 Basingdale Blvd #8 Vail, CO 81657 Window Placement Principles Considered/Applied • While architectural taste and styles clearly change with the times, certain architectural standards are time(ess and transcend the ages. Architectural concepts like proportion, balance, symmetry and harmony are as relevant today as they were in time of Andrea Palladio and the "Four Books on Architecture". • Windows play a critical role in the three most important aspects of home design. The first is appearance. Next to the shape of a house (Colonial, ranch, Cape Cod), windows are the most significant factor influencing how the place looks to the outside world. The second element is site embrace. Windows capture views and make the connection between the indoors and the natural world beyond. Last, windows are about comfort. They let in light and air and protect against extremes of weather. • When adding new windows to an existing wall, the trick is to keep the treatment consistent, with compafible trim, grille patterns, and muntin style. A modern plate-glass window looks out of place in a perfectly symmetrical antique facade. • Window placement should follow some consistent rhythm, to create visual clarity as well as to help avoid the creation of blank walls. Windows need not all be horizontally or verfically proportioned but rather their placement and orientation should take cues from the building's overall style and configuration. Below are a number of guidelines with respect to window placement: • Windows should be proportioned in a manner that creates a balanced elevation. Furthermore, window placement should be consistent with the overall vernacular design of the structure and windows should generally be verfically oriented. • Windows shoufd be placed on all four elevations. Blank walls with no windows are strongly discouraged. • Traditional window fenestration consistent with the proposed vernacular architectural style of a structure should be used whenever possible. Any window fenestration used on the front elevation should be carried through on the side and rear elevations. • All windows should incorporate some ornamental trim work. Simple aluminum window frames with no trim work are strongly discouraged 9/27/12 2801 Basingdale Blvd #8 Vail, CO 81657 3 19'-6" Proiect Narrative (as submitted to TOV — DRB) �'-' 1t2� ��-0 5/16--*--9'-6 3.�16�� . � , .. .�_ ��� .. _ The new window will match the existing windows that were approved for replacement in our original DRB submission. All windows that open are casement windows like the windows on the front of the units. This includes the windows we are replacing and the new window • The new window wiil be 42" off the floor • The full window unit rough opening is 96" x 54" • The components of the window unit is a 48" x 54" fixed picture window with a 24" x 48" casement window on either side of it. • The windows are white vinyl to match all other windows in the complex including the replacement windows previously approved • The new window will be trimmed with dark grey brick molding to match the existing and the outer trim will match the existing outer trim in both size and color • The left side of the new window unit will align with the left side of the window below and each vertical line in the windows (above and below) wilt line up with one another • The new window unit is designed to be 2x the width of the window below . � � � � � � r�s� 9 �� ., � � 2._,. ; :� ° , � � N ,� �,� 7. 6 � ., �; N � 7'-8 � ,�a�-z° � � ,�-- r_7- r2=�• 9/27/12 2801 Basingdale Blvd #8 Vail, CO 81657 4 . . Elevation of East Wali of building Vertical alignment with existing windows and horizontal alignment with deck rail rail height (42" off floor) From the inside the window sill is 42" above the floor level and the top is at 8' (same as kitchen ceilingj The bottom of the window is 8-10 feet off the parking lot the majority of what will be visible from the ground will be the wood ceiling and beams, the light fixture and the walls from the bathroom door to the end of the staircase depending upon the angle of view as Overall size based on existing windows (new window - 2x the window below in width and the same height) casement portion is same size Provides both view ( i.e. picture window) and ventilafion (casement windows on sides) C�'�`•� �-�p' ~�'"� �� �"'�< �'Se` � `,�t: . � � La= • 1'� °b:i. �'�.;'i�':.�, >,r _Vr,�t.�• 9/27 F w �.�...' .�.. �yv��, ��yy �� � ��'�~4��i+G�M��`t�. �, \ °�`' ' T � � � . I �I�.. . Y%� � � � �• +r �v �� �� � �� KIM��C,m cl- � . . .. �. � �.?` , ,Mr �c1k�Jy'.2'^' � +u�R." ... V � .e. a ' ]tt •sc �7 � �� . Framing & Installation Plan Structural requirements have been drawn up by a Colorado Licensed Structural Engineer, Kent Peterson (one of the acknowledged structural experts in Colorado) Current wall structure is 2x6 framing with %2" plywood sheathing outside and %2" plywood inside along with sheetrock. • All framing wifl be done from the inside and will be subject to a framing inspection by . � . the TOV. Once framing is approved and the window arrives it will be installed and trimmed out to match existing We will paint the trim before installing so that when completed it looks like it has always been there. Installation should take one day depending upon the weather. 9/27/12 K � � v�o�nn,� /Y�»� �,�1 oau - - 'G �il� ocs ey: wor� oacna. crt. ey: CONSULTING ENGINEERS �'�—Of vrq�ctNo._'_ �3—�2v_ er5 _- - -� �—, + __ _ r _ -�r; ..�__y _ ,_,r - _. �_ " �- i `-'T � __,��t�..+i�---7 -Z � �. � ' i+ � ��..j_,..._i.�--1-�-3��.. � i � � 1'� 1_Lf._,�_.�' �----r-- �. �'_t T r-� J y ---1 �--,-;- -r.}-rT-+---,�=•-,-.,--�-•-r-�-+�-;-+---- . �""'�.' . :--' � -r�-�- ._;~-�..��----"'i"' �"__' �_� 1_ �'�' '� •- ,_.iYl �-��- '— I _.., - _ _ � �� - . ;- �r ' _ . ' �' • • -'- - -- � . _.._.. ---' - ..�__._, .._- -' � �-- -. _ yi_L_�i� � _ . _ �-~ y . ��;�- = _- _T.,.� � .; _ _. _ - ,�- _ --__�;=� �--.. � T ��-= -��_,-_ -�-�-�,�.-^ T , . �_ _- -�:; - --�-��: -== '�� _ �_ __�_� -- -_� �-_ - - �; a_- --- _ � ::� � ��;��_. , = _-��.�, ��'=;:�=_ - - ;+: r 1__� �� - _�-_-� ___ ^�_ __ . --� _,. _ ._, _, . "-- -� ,'1^-�- -; -_ ,,� �_ �-� �:+�J-.�.- 2801 Basingdale Blvd #8 Vail, CO 81657 �— -��—.-��-��-�ffCLJ-l�rf�— — -- " _"._ :]D'V7fi_-�(� _. _}- � � _' ._ ..., � Town of Va i I Design Review Board has approved this design 9/27/12 2801 Bas Design Review Board . ACTION FORM � Department of Commumry DeveloDment �(�]�/ OT+ (]A �' 75 South FrontaOe Road, Vali, Colaado 81657 ni� r rnil� tel: 970.479.2139 tax:970.479.2�52 _-.,.,.,,-,r:.� ._.�_:_. web: www.vallpov.com Project Nama: NOViCK NEW E0.ST WINDOW DRB Number: DR8120464 �,���,�,: ADD A NEW WINDOW TO THE FAST S1DE OF UNIT N8 ON THE SECOND FLOOR. PartiaparKa: OWNER NOVICK, WALTER R. AND ALEXAN 09/25/2012 Phone: 913-908-5403 8299 E OTERO CIRClE CENTENNIAL CO 60112 APPLiCANT NOVICK, WAL7ER R. AND ALEXAN 09/25/2012 Phone: 913-908-5403 8299 E OTERO QRQE CENTENNIAL CO 80112 Vrojed Addresa: 2801 BASINGDALE BWD VAtI Location: CAMELOT TOWNHOMES UNTf 8 Lcqal Descrlptlon: Lot: 2 Bbck: 8 Subdhrislon: fAMELOT TOWNHOUSES Paroel Number. 2103-143-1100-8 Comments: Motlon By: Seoond By: Vote: Conditions: Planner. BOARD/STAFF ACTION Adlon: STAFFAPP Oste ot Approval: 09/25/2012 Cand: 8 (PLAN): No changes to these plans may be made without the writLen consent of Town of Vall stafl and/w the approprlate revlew commlttee(s). Cond: 0 (PIAN): DRB approval does not oonstitute a permit for building. Please conwlt with Town of Vail Buildirg personnd prior to oonstruction activities. Cond: 201 (PIAN): DRB approval shall rat become vallA for 20 days following the date of approval, pursuant to the Vall Town Code, Chapter 12-3•3: ADPEALS. Cond: 202 (PI.AN): Approval of this project shall lapse a�d become wid one (1) year folbwing the date of final approval, unless a buitdirg permit is issued a�d construction is commenced and is diligently pursued toward completlon. DRB Fee Paid: :20.00 � Add ifiona I I nformation Window Schedule • Rough Opening 96" x 54" Frame Size: 95 1/2" x 53 %" • Jeld-Wen Premium Vinyl Awning/Picture window combination window unit with even sight line • White Ext /White Int • Low —E 366 Clear High Altitude • U Factor 0:33, SHGC: 0.22 VT: 0:51, ER: 9.00 Town of Vail Structural Design Criteria (Questions call Marfin Haeberle ... another Kansas guy ... • Roof Snow Load: 80 PSF for roofs 4:12 or greater slope Seismic: Short period spectral response: Ss =035.0 • 100 PSF for decks and roofs less than 4:12 Long period spectral response: S1= 008.1 • Wind Speed: 90 mph (3 second gust), exposure B Site Class: determined by soils report • Frost Depth: 48" Adopted Codes & Standards: • 2009 International Residential Code • 2009 International Plumbing Code • 2009 International Mechanical Code • 2009 Internafional Fuel Gas Code • 2009 International Fire Code • 2009 International Energy Conservation Code • 2008 Nationa) Electrical Code • 2003 ICC/ANSI A117.1 (Accessibility Standards) • 2009 Amendments tocated in Ordinance No. 18, Series 2009 9/27/12 2801 Basingdale Blvd #8 Vail, CO 81657 � ���- � a - o sl � t *********************************************************************************�********** TOWN OF VAIL, COLORADO Statement ***************************************+**************************************************** Statement Number: R120001471 Amount: $1,835.38 09/26/201211:03 AM Payment Method:Credit Crd Init: WC Notation: Visa walter R. Novick ----------------------------------------------------------------------------- Permit No: B12-0416 Type: COMBINATION BLDG PERMIT Parcel No: 2103-143-1100-8 Site Address: 2801 BASINGDALE BLVD VAIL Location: CAMELOT TOWNHOMES UNIT 8 Total Fees: $2,420.99 This Payment: $1,835.38 Total ALL Pmts: $2,420.99 Balance: $0.00 ***********�***********************************�**********�********************************* ACCOUNT ITEM LIST: Account Code -------------------- BP 00100003111100 EP 00100003111100 MP 00100003111100 PF 00100003112300 PP 00100003111100 UT 11000003106000 wc 00100003112800 Description ------------------------------ BUILDING PERMIT FEES ELECTRICAL PERMIT FEES MECHANICAL PERMIT FEES PLAN CHECK FEES PLUMBING PERMIT FEES USE TAX 4°s WILL CALL INSPECTION FEE Current Pmts 593.25 172.50 160.00 159.63 30.00 700.00 20.00 T 0 WN �75 S�FRONTp6E Rp0 M D E U VAIL� CO 81657 976-479-2324 TERMINAL I.D.� 2902 MERGHANT k: UISA t�ki�k��k�8127� MAIL ORDER BAiCH; 080568 pUTH:02642B SEP Z6a 12 09:56 �, � , �.�_�a fC.!' I�. �'UCJiG��, TOTAL �1835.38 ��� ����� � �Q u I ABREE TO PA4 A80VE T01AL AMOUNT ACCORDING i0 CARD ISSUER R6REEI�NT (MERCHANT AGREEMENT IF CREDIT VOUCHER} l�RCHANT COPV TOWN OF VAIL' Project Street Address: 2801 Basingdale Blvd (Number) (Street) � � �c � � ��-' \/ Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970-479-2128 www.vailgov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Building/Complex Name: Camelot Townhomes Contractor Information Business Name: Edge Consulting Group Inc Business Address: 8299 E Otero Cir �;ty Centennial State: CO Contact Name: Chip Novick Contact Phone: 913.908.5403 #8 (Suite #) Project #: )`S � � ' oRg #: __ _DQP� I 2� �y ►q Building Permit #: �' �,"�' �� � � Lot #: Block # Subdivision: Work Class: New �,�) Addition �j Alteration (� Z�p: $0112 Type of Buildin Single-Family �) Duplex �j Multi-Family � Commercial � Other �j Townhouse Contact E-Mail: chip.novick@gmail.com work Type: I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state taws, and to build this structure according to the town's zoning and subdivision codes, design review ap- proved, Intemational Building and Residential Codes and other ordinances of the Town applicable thereto. X �ir� �� /Z��ti�- Owner/Owner's Representative Signature (Required) Applicant Information Applicant Name: Chip Novick Applicant Phone: 913.908.5403 Applicant E-Mail: chip.novick@gmail.com Project Information Walter R and Alexandra S H Novick Owner Name: Parcel #: 2103-143-11-008 (For Parcel #�, contaet Eagle County Assesaors Office at (970�28�0 or visit www.eaglecou nty. u slpatie) For Office Use Only: Fee Paid: Received From: Cash Check # CC: Visa / MC Last 4 CC # Auth # _ __ exp date: Electrical Mechanical Plumbing Building Interior O Exterior O Both O Valuation of Work Induded Plans Included Work OYes �INo OYes �No 2000 �Yes O)No QYes �No 8000 ! Yes �No �Yes �No 2000 Oi Yes ONo QYes QNo 33000 Value of all work being performed: $ 45000 (value based on IBC Section 109.3 & IRC Section 108.3� Electrical Square Footage 1280 Detailed Scope and Location of Work: Remodel kitchen baths, utiliry room including new appliances, vanities, showers, toilets, lighting, hardwood, carpet, drywall repair and painting. Exterior patio doors and windows will be replaced with new to the recently replaced kitchen window. All will be high efficiency and low e. (use additional sheet if necessary) Date Received: �� �1�-z� : ZIOZ : � d3S � ' � �2-Mar-20�2 �f � ; _ _.: 1 ' � � V —��l U '� � �! `� �� U � A PEN � � � En vironmentsl. Inc. 1990 S. Garrison St. Suite 6 Lakewood, CO 80227 O�ce 303-980-4401 Fax 303-980-4402 August 30, 2012 ASBESTOS CONTAINING MATERIALS SURVEY �"'�-'�'� �� . �=: ..�-_..----^ _ ..h,4. � � ; �F --�_ ; __ _ �, __ 8 � , � �. '�� t � ��� �h .��e�'h e y1 , � ._„� _ _...� ; ; �� u� � �H � �t . _ �+n.� .. ,r,rx�.`� � �;. a�:A.,.'� . - 2801 BASINGDALE BOULEVARD UNIT #8 Prepared For: Chip Novick VAIL, CO 81657 ._ __��____ --- I� ��- C _ _ _ �_} �� , �� � SEP o � 2012 —� i i �_, A.E.I. Job # 42312 '' �. �� ; 1 �a RE: Asbestos Survey Aspen Environmental, Inc. is pleased to submit this report on the asbestos survey conducted at 2801 Basingdale Blvd. Vail, CO 81657. Bulk samples of suspect asbestos containing materials were collected from 2801 Basingdale Blvd. Vail, CO. The bulk samples were delivered to Reservoirs Environmental Services, Inc. located at 5801 Logan Street Suite 100 Denver, Colorado. Results of the sample analysis are attached in the laboratory sample data sheets. The inspection was conducted in accordance with accepted protocol established by the E.P.A., current State of Colorado Regulations and within the reasonable constraints of time and cost. Further, the experienced inspector is duly qualified and licensed to perform the work conducted in the inspection. T'his cannot be construed that this is an absolute guarantee that there is no more unidentified asbestos containing material associated with the residence. PRINCIPAL FINDINGS Ceilin� Texture (popcorn) and Joint Compound Analysis of the ceiling texture and joint compound located on the main floor kitchen and entry has determined that the ceiling texture and joint compound contain between trace amounts and 8% chrysotile asbestos. � �.� > � �■I!I � �� ,. _ ��t� j �. 2 � Wall Texture and Joint Comnound Point Count Analysis of the wall texture and joint compound has determined that the wall texture and joint compound contains between 1.25-2.25% chrysorile asbestos. Drvwall Analysis of the drywall has determined that the drywall contains no asbestos. Ceramic Floor Tile Grout and Adhesive Analysis of the ceramic floor tile grout and adhesive (pictured below) located on the main floor has determined that the floor tile grout and adhesive contains no asbestos. . , .--Y� � . �: � r.. --- � ...� Ceramic Wall Tile Grout and Adhesive Analysis of the ceramic wall tile and grout (pictured below) located on the main floor kitchen has determined that the wall tile grout and adhesive contains no asbestos. � �._�- .�� � �w� �� . Sincerely, Harold W. Windle Manager Industrial Hygiene Jayson W. Windle State Certified Asbestos Inspector 4 � Town of Vail - Building Permit Package Property: 2801 Basingdale Blvd #S Va i I, CO 81657 Pa rce I : 2103-143-11-008 _.__..__��� � • . ���r����k _._, f� ��_: ,�� ���;� �' � � ' ZIOZ � o d3S '' ,, I , � I U ' _ -- .. . . � ���� � � � . . . _ _,�.__._,.. . . �'-...I Owners: Chip and Sande Novick 8299 E Otero Cir Centennial, CO 80112 913.908.5403 chip.novick@gmail.com sande.novick[a�gmail.com Table of Contents 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. CoverPage Table of Contents Project Narrative interior Remodel Checkiist Asbestos Testing and Abatement Plan Eagle County Assessor Records Main Floor Renovations Main Floor Details Bedroom Floor Bedroom Floor Details Mechanical Plans Electrical Plans Electrical Load Calculation Gas Piping and Plumbing Plans Summer Construction Staging and Parking Plans Minor Exterior Alteration Plan Pictures of Windows and Doors to be Replaced Door and Window Schedule Permit Fee Calcutation 9/5/12 2801 Basingdale Blvd #8 Vail, CO 81657 2 I Project Narrative 2801 Basingdale Bivd #8 was purchased "as is" from Wells Fargo after they foreclosed on the previous owner and took title. The property is in need of significant improvement and updating. The kitchen needs updating, the bathrooms are in bad shape and the boiler is in need of repair or replacement. Our plan is to remain within the existing footprint and renovate the interior of the unit completely. MAIN LEVEL: interior renovations on the main level will include removing the existing kitchen cabinets and two non load bearing walls and replacing the same with new cabinets, countertops and appliances. Lighting will be added and new flooring will be instalted. In the utility room, a new high efficiency combo boiler/hot water unit will be installed and the floor will be filed. The rock face of the fireplace will be removed and a new tile face will be installed. Hardwood floors will be installed in the kitchen and living areas. The bathroom will be renovated (new tile shower, tile floor, toilet, vanity and lights). New interior doors will be installed. Drywall will be patched, floated and textured and all surfaces will be painted. BEDROOM LEVEL: interior renovafions on the bedroom level will include removing the existing interior doors, trim and baseboard and replacing then with new. Light fixtures will be replaced. Carpet will be installed in the bedrooms, stairs and hall. Drywall will be patched, floated and textured and all surfaces will be painted. Before and After plans on provided on the next pages. 9/5/12 2801 Basingdale Blvd #8 Vail, CO 81657 3 I nterior Submittal Requirements DRB Approval Plan Review Fee Permit Applicadon Fam Enerqy Code Compliance Form Asbestos Project Checklist & Testing Results &/or Clearance Soils Report # of Plan Sets (PaP� �h) surveY/Site Plan Floor Plans Roof Pian Elevations Cross Sertions & Details Mechanical Plans Electrical Plans Gas Piping Plan (Ptumbing) Special Inspection Program Foundation Plan Framing Plan 9/5/12 Remc IMerior Remodel n/a J J n/a � n/a 3 n/a � n/a n/a n/a J r J n/a n/a J �del Checklist Check Box Attached Attached Page 5 and Report Attached Attached to Permit Appiicafion Attached Plans and Pages 6, 7& 9 of this document Attached and Page 11 of this document Attached and Page 12 & 13 of this document Attached and Page 14 of this document n/a 2801 Basingdale Blvd #8 Vail, CO 8 Windows J J � r (window U-value) J n/a 2 n/a J n/a J or window schedule n/a n/a n/a n/a n/a n/a 1657 May be staff approval Included in Remodel Included in Remodel Windows U Factor =.33 See page 18 Attached Plans and Pages 16, 17 and 18 of this document 4 Asbestos Tesfing and Abatement Project Checklist My �x�oject falis Mto the category d►ecked below: � WIII not disturb more tl�an the threshold Iimits identified above. � Tested negadve, or at 1% or bebw (1 copies of test results included) � Tested positive at more than 1%, requires abatement (1 copies of test results included) The walls and ceiling we intend to remove were tested for asbestos by Aspen Environmental on Friday August 31, 2012. The results (report attached) show that the walls and ceiling in question contain friable material. The ceiling texture contains 0% - 8% friable material, the joint compound contains 3� and the wall texture contains 2-3�0. As owners of this our primary residence, we (my self and my wife) can remove the sheetrock and ceiling texture ourselves. We plan to do just that and we will not hire any outside contractors to remove the material. We will properly package and dispose of the material at DADS in Denver and we will retain a copy of the manifest from DADS for our records. The email below from the State confirms this. Rf. ��,bestos ies! Results - 28U1 Basingdale Blvd FE Vai: CU Inbox Dek�e lunk ReD�Y RepIY A�� Forward Print 7o Do From. ASbe5lo5 Subjec! RE: Asbestos Tast R�sults - 280/ Bealnydsla Blvd s8 Vall, CO Datc. $eptember 5. 2012 4:50:37 PM MDT 70�. tlrhoetles�vallgov.com , mhaeberte�vellgov.com . Santle Novlck Cc. Chlp NOV�k � lf 3 Attachments. 9.9 KB s.y •�� � quck �. � To Whom It May Concem: Colorado regulations allow for a homeowner to conduct their own asbestos abatement within their primary residence, so long as they do the work themselves — no family, fiends, conVactors, etc., and the only requirement is that the material be disposed of at a landfill that accepts asbestos. The section oi Regulation No. 8 that allows this is III.B.1.c., not the opt-0ut provision specified below. Please feel free to contact me if you have any further questions or comments. Sincerely, Jeff Adams Jetfrey W. Adams Environmental Health Specialist II Air Pollution Control Division Colorado Department of Pubtic Health and Environment 4300 Cherry Creek Drive South Denver, CO 80246-1530 303-692-3273/jeftrAV.adams sfate.co.us ; �y. ..v.:�vi/ :1� 9/5/12 2801 Basingdale Blvd #8 Vail, CO 81657 -J 0 Eagle County Assessor Records: Pa rce I 2103-143-11-008 2801 Basingdale Blvd #8 Va i I, CO 81657 12.0' � • I 9/5/12 c` +� . . 0 cJ r!) 0 0 N (V M M 2801 Basingdal�'�Rid #8 Vaii, CO 81657 BAL 48.0 12.0' 20.0' 0 �r 0 N M � � Nortn Main Floor Renovations BEFORE s� � rz�-r� AFTER Eagle County Assessor Records: Parce12103-143-11-008 � 2801 Basingdale Blvd #8 Vail, CO 81657 North 9/5/12 2801 Basingdale Bivd #8 Vail, CO 81657 7 Main Floor - Details Demo on Main floor • Interior poors & Trim • Baseboard • Masonite layer on floors • Bathtub, toilet, vanity • Kitchen cabinets • Kitchen walls (west and north) • Boiler and hot water heater New in Bathroom • Tile shower & floor • Vanity • Toilet • Light & Fan New in Kitchen. Ufility and Living Area • Interior doors • Cabinets, countertops appliance and light fixtures • Hardwood flooring and tile • Boiler (Triangle Prestige Excellence) • Fireplace facing • Drywall patched as necessary • Paint • Smoke alarms 9/5/12 2801 Basingdale Blvd #8 Vail, CO 81657 8 Bedroom Floor :' • � � �a'-r, � , �', I� Replace Window `' i. - with same rough I dimensions 9'-r 1 r!2" t'-8 1 7" � 7,-,1" ---- Q: " ' � � Demo tub, � _� �- � � � � ��toilet & vanit , � . lti~ , � � ��-� 1 �1 ' � � ,� „ �-, Replace Window �� � a,�,�- ;_, o� with same rough '=' � «, e�, ti, n, dimensions �• i U'-3 ii2" b'- f G 1. 2" < T � 6'-7'. �, 1 �. 1 1. ��, � . . �. � 'L � u � � � � .1 r� i�i After (No Changes) r �� •-r � Eagle County Assessor Records: Parce12103-143-11-008 � 2801 Basingdale Blvd #8 Vail, CO 81657 North 9/5/12 2801 Basingdale Blvd #8 Vail, CO 81657 9 Bedroom Floor - Details Demo on Bedroom floor • Doors & Trim • Baseboards • Masonite layer on floor • Bathtub, toilet, vanity New in Bathroom • Tile shower & floor • Vanity, toilet and door • Light & Fan New in Bedrooms • Interior doors • Closet closet doors • Drywall patched as necessary • Carpet • Paint • Light fixtures • Smoke alarms 9/5/12 2801 Basingdale Blvd #8 Vail, CO 81657 10 Range Fan Exhau� Duct Mechanical Plan Main Floor 19'-6' � ���:,'';. J �� 9/5/12 Gas pipes• ' 19'-6" � I. Soi4er I —.i f � tin�.:�- l� . throom F�n Cl I ��—�-r-- T— J'-6' —T� I`—��-ri- NOTE: • Boiler/HW unit will hang on wall and vent via new flue through the roof penetration from the existing boiler & hot water heater • Drain will be insta�lec! in utility room floor • Bathroom fans wt�� � U::� exisfing ducts • Range Hood will vent through outside wall as it 2801��aseingdaQe-Blvt! #8 Vail, CO 81657 Eagle County Assessor Records: Parce12103-143-11-008 � 2801 Basingdale Blvd #8 Vail, CO 81657 North �� Tnanyle presrigeExcel�ence � � � - - ALL-IN-ONE High Efficiency Condensing Stsinless Steel Wa11 Mounted Gas Boiler with Built in "TanN-In-Tank" m 1neR�tllq�E�cefr��... ....i...,.�..�, �... ��r.oTtra�n. , . OMbnMlnatFVelWein�HUtrnNeraeinMllrlNcni�.� � a� o.omc�na+eo avn a nom..ns ro� wn«. FW�m _ . Blf�. KUE fllGwry n BuINn ] 6p�E Syse� . vuW um,wna Gwmr Mvia�nhwwMCwvnr� ' Srr�EraUNOO.Rev �bw�N�y . mBUOnOF29�W . Bui1.�FWUU.a=eM�nT�ni. • 0r�'���f.. . soecmcr�ons 8 PMOrmente ��IIR � FnnHq rrlr�� Centrol • •��■ • O w�.,,�� . � ,, °�:�;a.��� ., h �m��� �.a.s.��,�.,�,,r. ]�if OEp1EfHY �� '�.nM b m��m�n n� �,. � .., � .�.., w �a,a � �. , , W�..��.����... �� ���������;� � � •.�p��Obq�wM�+Wmirti�e�. � H �nwymo�rr.a.wnm�.c� . ��� �T.� � , � ���. i wsbm �YbwaPP�VOracM�c „ • � �!9lIW n.�,.i.. .....,.... r. rw�w�m�.�sYOn s w,•vu.n .__— �+V�N�����V� 6�M�1 inun w.ncnomw 6 ; �s,c a.,+�..r �..am.c« , s. �� µ � cavacn�.nvo.v�aw.v e.com>,.uoyL.,,��.� O�� Tnanyle�", �! � p Elect Servi 100 AMP Electrical Plan (load calculation next page) 100 Main Floor AMP Panel gdale Blvd #8 Bedroom Floor Eagle County Assessor Records: Parce12103-143-11-008 � 2801 Basingdale Blvd #8 Vail, CO 81657 North 12 Electricai load Calculation __ Residential Standard Calculation Version 2017 L STEP 1� Articie 220.d2 8 220.52 Select____ : 1 1280 ' General Lighting load VA 2 Small Appliance 3.000 VA 1 Laundry cirouil 1,500 VA Gen.Lgt, Sm App.3 Laun. Load 4,5� VA Novick Residence Company Name AOOress City, State, Zip Code Telephone 8 Fax a�i2 io:o9 3,000 VA � 100%= 3,000 V/1 1,500 VA � 35% = 525 VA' VA � 25% = VA STEP 2 Article 220.50 8 220.51 �J� General LlghGny Damand Load MC Condenser 3 Fixed Eleetrle Spaee Hsatinq QTY � Total 0 A/C # 1: � VA AHU 1 Select VA� Qty '� Heatlnp Load VA A/C-__ tJ2 � VA AHU 2 Select VA Qt�_ �� CU Load VA A/C #3 : _ qH� 3 Select :— Qc •.1 . `—�' - A/C #4 C VA AHU 4 Select yq QtY S Gnal�r ot Hut � 10014 vsJUC Q/00X A/C #5 : AHU 5 Select J��_� ' STEp /►�tlCls 220�3 � Applianee Demand Load G�S �: 1 'YVetgrHeater VA 1,;00 VA: 1 � Refigerator 1,500 VA Dryer Dsmand Losd 600 VN :. � Freezer yq �. 300 V 1 � Diahwasher 1,300 VA Range Demand Load 690 VN' 1 � Disposal 690 VA 100 VA � 1 � R/ Hood 700 VA Ssrvlea Dsmand !, Z00 V 1 � Microwave 1,200 VA 4,000 V—�� � M���e VA Demand Load 1 70 VEk . � � Mini Refng VA 400 VA� �wne Gr ; VA Neutral Demand 5.000 V� � Insta Hot � yq 1, 500 VA, �' Ironing Center VA MIn.Service Req. J select . I Jacuzzi Tub VA _' select : � Spn�kler Pump � VA Min. Feeder sfze � select :� WeB Pump � VA Min Neutraf s�xc � select ' 1 Fountain Pump � VA Eq. Grding Cond. select � Elevator " VA _.�__.__, � Equip. Panel ' VA t00%Demand ' GATES ' VA No Oemsnd � Other load u ' VA No Demand Total Appliance �oad 4 a more demand f� 75% pius 10096 demand loads STEP 4 A`rticle 220.54 ElecUic Ctolhes Dryers 5,000 VA STEP 5 Aiticle 220.55 Electric Ranges ' Cd C demand 8000' or Number of appliances 1 Cooktop Cd B demand i J1 cnedc eox i« c�as rtanqe ��op Col B demand Oven(s) 5,50o W Cd 8 dertl2nd Oven(s) Col 8 demand Number of appliances 1 D�m. F�por 8o°i� Cooktop 3 Oven Demand Load 4,400 W 3,525 VA va 4,043 VA� 5,000 VA 4,400 Vi4 16,968 VA 71A 69 A ' 100 A 4 � 4 ' 8 __ � Copper 5,390 VA 4,043 Vl4 Eagle County Assessor Records: Parce12103-143-11-008 2801 Basingdale Blvd #8 Vail, CO 81657 Gas Piping Plan and Plumbing Elements Gas Plan Details • 1" CSST Pipe • Total Developed Length • 26 feet • Branch Lengths • 4 feet • 18 feet • 4 feet • Boiler/Hot Water • 30 -110 MBH (CFH) • Gas Range • 36,650 BTU (total) • Burners • 15,000 • 11,000 • 6,500 • 3,400 • 750 Main Floor Eagle County Assessor Records: Parce12103-143-11-008 � 2801 Basingdale Blvd #8 Vail, CO 81657 North Bedroom Floor 9/5/12 2801 Basingdale Blvd #8 Vail, CO 81657 14 Summer Construction Staging / Parking Plan • Dumpster will be place on one of the surface parking spots for unit #8. It will �be "j�"`°`�'-•� removed following demolition and this space will be used for parking ._..��..,,..a • Sub contractor parking will be in the other � parking spot, on the street and in front of the unit itself • Winter Plan: It is anticipated that the majority of the work will be completed by November 1. Any parking required after November 1 wilt be in the unit 8 spaces only � � � �� . . T ,. � �.� �� , ����� � ''�.�-�'' : „� . .. �.� Eagle County Assessor Records: Parce12103-143-11-008 2801 Basingdale Blvd #8 North Vail, CO 81657 � .:�� £���: ��' 9/5/12 2801 Basingdale Blvd #8 Vail, CO 81657 15 e , ��; Minor Exterior Alteration - Window and Door Replacement Project narrative: The existing patio doors are original to the unit. They are aluminum frames and single pane glass sliding doors. The locks are inoperable (see photos page 17). We plan to replace these doors with Jeld-Wen Premium viny) doors (see schedule page 18) to fit the existing rough opening and we will trim the exterior as it is trimmed today. The doors will be white like the other units that have replaced their rear patio doors. The bedroom windows are in need of replacement (see photos page 17). We will replace them with Jeld-Wen Premium Vinyl sliding windows (see schedule page 18) that fit the existing rough openings. They will be white like the vinyl windows that were approved for the front of each unit and we will trim the new windows and doors as the exterior is trimmed today. 9/5/12 2801 Basingdale Blvd #8 Vail, CO 81657 16 Windows and Patio Doors to be replaced Exterior/interior of Bedroom windows to be replaced . �, ���� , � _ !� �"�X�,+,� 1 .11$ 4 ��� ;�` _ _ _ -- � r �M� � � =� � � , . .. __ .____. " �5�� . ... ...... _.�.�.�.. � � 4 ,, � - - _�__�_�..�- � � �:: � __ r ` ` _` ~ I ,�-- �= : =�° _T ; ��`� �'� --- � _ - - � ' � ^ ,� � "_ � � �� _.. _ _. �.,�.., .... , , :��::: Master Bedroom patio doors to be replaced Living area patio doors to be replaced 9/5/12 2801 Basingdale Blvd #8 Vail, CO 81657 17 Proposed Doors and Windows (.leld-Wen Premium Vinyl) PO#: PRO)ECT NAME: Vdil R�Oject REFERENCE: REVISED 8/28/2012 LINE NO. LOCATION BOOK CODE UNIf QiY EICTENDED SIZEINfO DESCRIPTION PRICE VRICE Lir� 1 Sliding Doors with Blinds VSDPR3N1o880 Frame Size: 107 7/8 x �9 1/2 Rough Opening:ll� 3/8 X 8c► Premium Ymyl SNding Patio Door 3 Panel, Nail Fin (1 1/4" setbadc). White Ext/White IM , OXO (Slides Right/Outride looking In) Nartow Stlle, (1/3 Vent) Vent Width = 36 , � IG w/IMemal Blinds(Titt/Raise) dear Tempered , 1/8 in - 1/8 out , Select Screen with Fiberg�ass Mesh, White Ex[ Hardware, White Int Hardware, Setondary Ven[ Stop, Groove Fller Ir�, Viewed fraw Eiterior. Scal�: 1/!" s 1• a►i�, o�'z�, U-factor: 0.47, SFK'�C: 0.62, VT: 0.65, CR: 37.00, ER: 16.00 oEV 1oix.aaswnov s.»:laro�liz) wo ;1,722.20 2 ;3,444.40 LMe- 2 Slider-eadc eedroom ROUgh Opening:74 1/2 X 53 � �� Vlew�d iran Ealerior. Scalet 1/1" � 1• Frame Size: 74 x 52 1/2 Premium vnyl Sliding 1Nmdow 3 Panel, NlRh Even Sight l.ine, Nail Fn (1 1/4" setback), WhKe Ext/Wlute Int , XOX (1/3 Vent) VeM Width = 24 13/16 , Low-E 366 Clear Hph Altihide Standard Saeen with Fiberglass Mesll, White Int Hardware, Mag-Lock(s), 2 locks, �Meets 5.7 sqft EcNess (2nd floor and above)', Groove Filier Int, AAMA, OP-35, U-Factor: 0.33, SFIGC: 0.22, VT: 0.51, CR: 53.no, ER: 9.(N) vtv mi:.zasselrov s.nz (aro�iu) wo s37134 1 ;371.34 L.ine- 3 Slider-Middie Bedroom Rough Opening:5o 7/8 X 53 Ratne Size: St) 3J8 x 52 1/2 Premium Yu�yi Sliding Window With Even Sight Line, Nail Fin (1 1/4' setback), White Ext/Whi[e IM , XO (LH) Vent Widtli = 25 7/16 , Low-E 366 CJear High NtiNde � Stardard Screen with Fibergiass Mesh, White Int Hardware, Mag-Lock(s), 2 Locks, •Meets 5.7 sqR Eyress (2nd floor and above)�, Groove F�Iler Int, v+....e f.o�.� ert.�o.. sc�a: i/�.. � i.� MMA, DP-35, U-Factor: 0.33, SHGC: 0.22, VT: 0.51, CR: 53.Ix), ER: 9.(N) oEV zou.zosseioov s.n2 (ouo�liz) wo s254.06 1 =254.(� 9/5/12 2801 Basingdale Bivd #8 Vail, CO 81657 18 0 Building Permit Fee Calculation Renovation of 2801 Basingdale Blvd #8 Total Valuation Permit Fee Plan Review Fee Construction Use Tax Recreation Fees Will Call Inspection Total Buildin� Permit 9/5/12 659� $45,000 $846 $550 $700 $5 $2,101 2801 Basingdale Blvd #8 Vail, CO 81657 19