Loading...
HomeMy WebLinkAboutB12-0210 - REV1 - 090412 PLANSSCALE PROJECT NUMBER DRAWN BY CHECKED BY COPYRIGHT 2012 1DRC PRELIM. REVIEW05.12.11 2BID SET06.15.11 3T.O.V. PERMIT SET05.24.12 4T.O.V. INT. PERMIT SET08.30.12 12" = 1'-0" 1476 WESTHAVEN DR. UNIT #3 (COLDSTREAM) VAIL, CO 81657 PARCEL #210312108003 ACCOUNT #R013068 A1.00 COVER SHEET 0611 KOELBEL RESIDENCE INTERIOR ALTERATION ML ML T.O.V. INTERIOR PERMIT SUBMITTAL 08.30.12 DRAWING INDEX GENERAL A1.00 COVER SHEET A1.01 GENERAL NOTES ARCHITECTURAL A2.00 SECOND FLOOR DEMO PLAN A2.01 SECOND FLOOR PLAN A2.02THIRD FLOOR DEMO PLAN A2.03THIRD FLOOR PLAN A2.04SECOND FLOOR LIGHTING & ELECTRICAL PLAN A2.05THIRD FLOOR LIGHTING & ELECTRICAL PLAN VICINITY MAP GRAPHIC SCALE = 150' PROJECT NARRATIVE THE PROPOSED INTERIOR RENOVATION INCLUDES THE FOLLOWING: 1.RECONFIGURED INTERIOR WALLS. 2.NEW FINISHED FLOORINGS. 3.NEW FIXED FINISHES. 4.NEW BATHROOM FIXTURES. 5.NEW KITCHEN FIXTURES & APPLIANCES. 6.NEW CABINETRY & COUNTERTOPS. 7.NEW LIGHTING. 8.NEW BUILT-IN CABINETRY PROJECT DIRECTORY OWNER ELDORADO REALTY CO 5291 E. YALE AVE DENVER, CO 80222 303.662.0657 P ROBERT KOELBEL BOB@KOELBELHOMES.COM GENERAL CONTRACTOR MINICK CONSTRUCTION PO BOX 4018 VAIL, CO 81658 T.O.V. CONSTRUCTION LICENSE #24B 970.904.5066 P DAVE MINICK DKMINICK@YAHOO.COM ARCHITECT 8150 ARCHITECTS LLC PO BOX 3604 VAIL, CO 81658 970.376.3326 P 888.879.2105 F MATT LEE AIA, LEED AP MATT@8150ARCHITECTS.COM UNIT #3 WESTHAVEN DR GORE CREEK COLDSTREAM NO.DESCRIPTIONDATE RECEIV VED 09/04/12 A101 1 SIM 101 Room name 101 1 A101 SIM 1i 1t 1 1A101 SIM SECTION ELEVATION DETAIL/ENLARGED PLAN GRID REVISION 0 NORTH ARROW ELEVATION WALL TAG WINDOW TAG DOOR TAG ROOM TAG Name Elevation ROOM NAME SCALE PROJECT NUMBER DRAWN BY CHECKED BY COPYRIGHT 2012 1DRC PRELIM. REVIEW05.12.11 2BID SET06.15.11 3T.O.V. PERMIT SET05.24.12 4T.O.V. INT. PERMIT SET08.30.12 As indicated 1476 WESTHAVEN DR. UNIT #3 (COLDSTREAM) VAIL, CO 81657 PARCEL #210312108003 ACCOUNT #R013068 A1.01 GENERAL NOTES 0611 KOELBEL RESIDENCE INTERIOR ALTERATION ML ML T.O.V. INTERIOR PERMIT SUBMITTAL 08.30.12 GENERAL NOTES 1. THE AIA DOCUMENT A105, STANDARD FORM OF AGREEMENT BETWEEN OWNER AND CONTRACTOR FOR A RESIDENTIAL OR SMALL COMMERCIAL PROJECT, 2007 EDITION, IS HEREBY MADE A PART OF THESE CONTRACT DOCUMENTS. COPIES ARE INCLUDED IN THE PROJECT MANUAL AND ARE AVAILABLE FOR INSPECTION AT THE OFFICES OF THE ARCHITECT. 2. THE CONTRACT DOCUMENTS CONSIST OF THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, THE GENERAL NOTES, THE SPECIFICATIONS, AND THE DRAWINGS, WHICH ARE COOPERATIVE AND CONTINUOUS. WORK INDICATED OR REASONABLY IMPLIED IN ANY ONE OF THE DOCUMENTS SHALL BE SUPPLIED AS THOUGH FULLY COVERED IN ALL. ANY DISCREPANCY BETWEEN THE DIFFERENT PARTS SHOULD BE REPORTED TO THE ARCHITECT IMMEDIATELY. 3. ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ORDINANCES, THE CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. 4. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS, TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC. TO OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE INDUSTRY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TO THE ATTENTION OF THE ARCHITECT ANY CONDITIONS WHICH WILL NOT PERMIT CONSTRUCTION ACCORDING TO THE INTENTIONS OF THESE DOCUMENTS. IT IS THE RESPONSIBILITY OF THE ARCHITECT TO PROVIDE DETAILS AND/OR DIRECTIONS REGARDING DESIGN INTENT WHERE IT IS ALTERED BY EXISTING CONDITIONS OR WHERE NEGLECTED IN THE DOCUMENTS. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECTS OF THIS PROJECT, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT. 5. VERIFY ALL DIMENSIONS, EXISTING CONDITIONS AND UTILITY LOCATIONS ON THE JOB SITE PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIALS. 6. NOTIFY ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECT BEFORE CONSTRUCTION CONTINUES IN THOSE AREAS. 7. CONTRACTOR TO SUMBIT CUT SHEETS/SPECIFICATIONS AND SAMPLES* OF ALL PRODUCTS & MATERIALS FOR ARCHITECT'S APPROVAL PRIOR TO ORDERING PRODUCTS & MATERIALS. *SOME PRODUCTS MAY NOT REQUIRE A SAMPLE TO BE SUBMITTED (COORDINATE W/ ARCHITECT). 8. ANY MATERIALS PROPOSED FOR SUBSTITUTION OF THOSE SPECIFIED OR CALLED OUT BY TRADE NAME IN THESE DOCUMENTS SHALL BE PRESENTED TO THE ARCHITECT FOR REVIEW. THE CONTRACTOR SHALL SUBMIT SAMPLES WHEN REQUIRED BY THE ARCHITECT AND ALL SUCH SAMPLES SHALL BE REVIEWED BY THE ARCHITECT BEFORE THE WORK IS PERFORMED. WORK MUST CONFORM TO THE REVIEWED SAMPLES. ANY WORK WHICH DOES NOT CONFORM SHALL BE REMOVED AND REPLACED WITH WORK WHICH CONFORMS AT THE CONTRACTOR'S EXPENSE. SUBCONTRACTORS SHALL SUBMIT REQUESTS AND SAMPLES FOR REVIEW THROUGH THE GENERAL CONTRACTOR WHEN WORK IS LET THROUGH HIM OR HER. REQUIRED VERIFICATIONS AND SUBMITTALS TO BE MADE IN ADEQUATE TIME AS NOT TO DELAY WORK IN PROGRESS. 9. SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT FOR HIS OR HER REVIEW WHERE CALLED FOR ANYWHERE IN THESE DOCUMENTS. REVIEW SHALL BE MADE BY THE ARCHITECT BEFORE WORK IS BEGUN, AND WORK SHALL CONFORM TO THE REVIEWED SHOP DRAWINGS, SUBJECT TO REPLACEMENT AS REQUIRED IN PARAGRAPH 8, ABOVE. 10. THE BUILDING INSPECTOR SHALL BE NOTIFIED BY THE CONTRACTOR WHEN THERE IS NEED OF INSPECTION AS REQUIRED BY THE INTERNATIONAL RESIDENTIAL CODE, THE INTERNATIONAL BUILDING CODE OR ANY LOCAL CODE OR ORDINANCE. 11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY AND CARE OF ADJACENT PROPERTIES DURING CONSTRUCTION, FOR COMPLIANCE WITH FEDERAL AND STATE O.S.H.A. REGULATIONS, AND FOR THE PROTECTION OF ALL WORK UNTIL IT IS DELIVERED COMPLETED TO THE OWNER. 12. DO NOT SCALE DRAWINGS. ALL DIMENSIONS NOTED TAKE PRECEDENCE OVER SCALED DIMENSIONS. DIMENSIONS NOTED WITH "N.T.S." DENOTES NOT TO SCALE. 13. PLAN DIMENSIONS ARE TO FACE OF STUD/STRUCTURE, FACE OF COLUMN OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE TO FACE OF STUD/STRUCTUR, FACE OF COLUMN, FACE OF CONCRETE, TOP OF CONCRETE, TOP OF PLYWOOD, TOP OF WALL PLATES OR TOP OF BEAMS UNLESS OTHERWISE NOTED. 14. THE CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND STAKE OUT PROPOSED WORK FOR OWNER AND ARCHITECT APPROVAL PRIOR TO BEGINNING ANY SITE WORK. 15. CONTRACTOR SHALL VERIFY AND COORDINATE ALL OPENINGS THROUGH FLOORS, CEILINGS, AND WALLS WITH ALL ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS. THE CONTRACTOR SHALL FIELD COORDINATE AND OBTAIN APPROVAL FROM THE ARCHITECT & ENGINEER BEFORE ANY CUTTING, NOTCHING OR DRILLING OF ANY CAST-IN-PLACE CONCRETE, STEEL FRAMING, OR ANY OTHER STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE BUILDING. 16. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING, FLOOR AND WALLS SPACES. VERIFY LOCATIONS WITH ARCHITECT. 17. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES, TOILETS, TOILET ACCESSORIES, GRAB BARS, CABINETRY, COUNTERTOPS, SHELVES AND CLOSET RODS. 18. CONTRACTOR WILL ASSUME RESPONSIBILITY OF ITEMS REQUIRING COORDINATION AND RESOLUTION DURING THE BIDDING PROCESS. BIDDING NOTES 1. DRAWINGS OF EXISTING CONDITIONS ARE BASED OFF OF ROUGH FIELD SURVEYS. ALL LOCATIONS, DIMENSIONS, AREAS, SCHEDULES, QUANTITIES & MATERIAL TAKEOFFS OF EXISTING CONDITIONS GIVEN ARE FOR REPRESENTING THE SCOPE OF THE WORK & GENERAL ORDER OF MAGNITUDE ESTIMATING. THEY ARE NOT TO BE RELIED UPON FOR ACCURATE BID ESTIMATING. IT IS THE RESPONSIBLITY OF THE CONTRACTOR TO FIELD VERIFY ALL LOCATIONS, DIMENSIONS, AREAS, SCHEDULES, QUANTITIES & MATERIAL TAKEOFFS PRIOR TO SUBMITTING HIS/HER BID. 2. CONTRACTOR TO INCLUDE ALL ASSOCIATED COSTS (EXCEPT FOR BUILDING PERMITS & SIMILAR FEES) TO PERFORM THE WORK INCLUDING BUT NOT LIMITED TO: DEMOLITION, HAUL & DUMP FEES, SITE FENCING, BUILDING PROTECTION, OFF & ON-SITE MATERIAL STORAGE. 3. CONTRACTOR TO PROVIDE EVIDENCE OF INSURANCE. CONTRACTOR & SUBCONTRACTORS TO NAME OWNER AS "ADDITIONALLY INSURED" FOR THE DURATION OF THE WORK. ABBREVIATIONS ABVABOVE AFFABOVE FINISHED FLOOR APACCESS PANEL ACACOUSTICAL ADAAGADA ACCESSIBILITY GUIDELINES ADDADDENDUM ADJADJACENT ALTALTERNATE ALUMALUMINUM AIAAMERICAN INSTITUTE OF ARCHITECTS ANSIAMERICAN NATIONAL STANDARDS INSTITUTE ASTMAMERICAN SOCIETY FOR TESTING & MATERIALS ADAAMERICANS WITH DISABILITIES ARCHARCHITECT(URAL) ASIARCHITECT’S SUPPLEMENTAL INSTRUCTIONS ABAARCHITECTURAL BARRIERS ACT AHJAUTHORITY HAVING JURISDICTION BASMTBASEMENT BRGBEARING BVLBEVELED BITBITUMINUOUS BLKBLOCK BLKGBLOCKING BOTBOTTOM BLDGBUILDING CPTCARPET(ED) CSMTCASEMENT CCAULK(ING) CLGCEILING CENTERLINE CTCERAMIC TILE CLRCLEAR CLCLOSET COLCOLUMN CONCCONCRETE CMUCONCRETE MASONRY UNIT CONSTCONSTRUCTION CSICONSTRUCTION SPECIFICATIONS INSTITUTE CONTCONTINUOUS CJTCONTROL JOINT CPRCOPPER CUSTCUSTOM DDEPTH, DEEP DTLDETAIL DIMDIMENSION DRDOOR DSDOWNSPOUT DTDRAPERY TROUGH DWGDRAWING(S) DFDRINKING FOUNTAIN ELECELECTRIC(AL) ELEVELEVATION(S) ELELEVATOR ERVENERGY RECOVERY VENTILATOR EQEQUAL ETCET CETERA EPDMETHYLENE PROPYLENE DIENE MONOMER EXHEXHAUST EXISTEXISTING EXTEXTERIOR FOCFACE OF CONCRETE (COLUMN) FOFFACE OF FINISH FOMFACE OF MASONRY FOSFACE OF STRUCTURE (STUD(S)) FINFINISH(ED) FFEFINISHED FLOOR ELEVATION FEFIRE EXTINGUISHER FDCFIRE DEPARTMENT CONNECTION FHCFIRE HOSE CONNECTION FECFIRE EXTINGUISHER CABINET FPLFIREPLACE FPFIREPROOFING FLGFLASHING FLRFLOOR(ING) FDFLOOR DRAIN FTGFOOTING FNDFOUNDATION FBOFURNISHED BY OTHERS (OWNER) FPHBFREEZE PROOF HOSE BIB FURRFURRED, FURRING GAGAGE, GAUGE GVGALVANIZED GCGENERAL CONTRACT(OR) GLGLAZING, GLASS GSFGROSS SQUARE FOOTAGE GYPGYPSUM GWBGYPSUM WALL BOARD HBHOSE BIB HDWHARDWARE HDRHEADER HTGHEATING HVACHEATING VENTILATING & AIR CONDITIONING HTHEAVY TIMBER, HEIGHT HCHOLLOW CORE HMHOLLOW METAL HORHORIZONTAL HWHHOT WATER HEATER INCLINCLUDE(D), INCULDING IDINSIDE DIAMETER IBOINSTALLED BY OTHERS/OWNER INSINSULATE(D), INSULATION INTINTERIOR IBCINTERNATIONAL BUILDING CODE, INSTALLED BY CONTRACTOR ICCINTERNATIONAL CODE COUNCIL IRCINTERNATIONAL RESIDENTIAL CODE JCJANITOR’S CLOSET KITKITCHEN LAMLAMINATE(D) LAVLAVATORY LHLEFT HAND LLENGTH LDTLIGHT & DRAPERY TROUGH LTLIGHT, LIGHT TROUGH LTLLINTEL LVRLOUVER MHMANHOLE MFRMANUFACTURE(D), MANUFACTURER MOMASONRY OPENING MTLMATERIAL MAXMAXIMUM MECHMECHANIC(AL) MEPMECHANICAL/ELECTRICAL/PLUMBING (ENG.) MCMEDICINE CABINET MBMEMBRANE METMETAL MMETER(S) MMMILLIMETER(S) MINMINIMUM MIRMIRROR MISCMISCELLANEOUS MULLMULLION NFPANATIONAL FIRE PROTECTION ASSOCIATION NATNATURAL NSFNET SQUARE FOOTAGE NLSFNET LEASABLE SQUARE FOOTAGE NOMNOMINAL N/ANOT APPLICABLE NICNOT IN CONTRACT NRNOT-RATED, NOISE REDUCTION NTSNOT TO SCALE OCON CENTER OPGOPENING OPPOPPOSITE OPHOPPOSITE HAND OHOVERHEAD PRPAIR PKPARKING PVMTPAVEMENT PLPLASTIC LAMINATE, PLATE, PROPERTY LINE PTPOINT, PRESSURE TREATED PSFPOUNDS PER SQUARE FOOT PSIPOUNDS PER SQUARE INCH QTQUARRY TILE RECRECOMMENDATION(S) REREFER(ENCE) REFRREFRIGERATOR REINFREINFORCE(D), REINFORCING RFIREQUEST FOR INFORMATION/CLARIFICATION REQ’DREQUIRED RESRESILIENT REVREVISION(S) REVSREVERSE RHRIGHT HAND RRISER R&SROD & SHELF RDROOF DRAIN RDTRECESSED DRAPERY TRACK RFGROOFING RMROOM ROROUGH OPENING R/SROUGH SAWN SSEALANT SHTGSHEATHING SMSHEET METAL SIMSIMILAR SCSOLID CORE SPECSPECIFICATION(S) SQSQUARE SQ FTSQUARE FOOT(AGE) STDSTANDARD STSTAIN SSSTAINLESS STEEL STLSTEEL SDSTORM DRAIN STRUCT STRUCTURE, STRUCTURAL TELTELEPHONE TVTELEVISION THRTHRESHOLD T&MTIME & MATERIALS T&GTONGUE & GROOVE TOBTOP OF BEAM TOSTOP OF SLAB/STEEL/STRUCTURE TOWTOP OF WALL TBTOWEL BAR TRTRANSOM TTREAD TSTUBE STEEL TYPTYPICAL ULUNDERWRITERS LABORATORIES UFASUNIFORM FEDERAL ACCESSIBLITY STANDARDS UNOUNLESS NOTED OTHERWISE VBVAPOR BARRIER VIFVERIFY IN FIELD VERTVERTICAL VCTVINYL COMPOSITION TILE WBWALL BOARD WCWATER CLOSET WPWATERPROOF(ING) WWFWELDED WIRE FABRIC WWIDTH, WIDE WDWWINDOW W/WITH W/OWITHOUT WDWOOD NO.DESCRIPTIONDATE RELOCATE DOOR TONEW WALLDEMO HEARTHDEMO WALLS DEMO GUARDRAIL DEMO FIREPLACE& FLUE DINING ROOMRELOCATELIGHTFIXTURE DECK 1 LIVING ROOM STAIRENTRY BATH 1BEDROOM 1 CL 3 ELEC. P KITCHEN CL 2CL 1 1 4 3 A B CD E 2 SCALE PROJECT NUMBER DRAWN BY CHECKED BY COPYRIGHT 2012 1DRC PRELIM. REVIEW05.12.11 2BID SET06.15.11 3T.O.V. PERMIT SET05.24.12 4T.O.V. INT. PERMIT SET08.30.12 As indicated 1476 WESTHAVEN DR. UNIT #3 (COLDSTREAM) VAIL, CO 81657 PARCEL #210312108003 ACCOUNT #R013068 A2.00 SECOND FLOOR DEMO PLAN 0611 KOELBEL RESIDENCE INTERIOR ALTERATION ML ML T.O.V. INTERIOR PERMIT SUBMITTAL 08.30.12 1/4" = 1'-0" 1 SECOND FLOOR DEMO PLAN NOTE: ONLY THE INTERIORSCOPE OF WORK (SHOWNABOVE DASHED LINE) ISINCLUDED IN THIS PERMIT SETNOTE: THE EXTERIOR SCOPEOF WORK (SHOWN BELOWDASHED LINE) WAS INCLUDEDIN THE EXTERIOR PERMITSET DATED 05.24.12 (PERMIT# B12-0210) GENERAL NOTES:1. GRAY HATCH INDICATES EXISTING WALLS. 2. DASHED LINES INDICATE DEMOLISHED/REMOVED.NO.DESCRIPTIONDATE DEMO WALLS, DOORS,STAIRS, HANDRAILS,CABINETS, FIXTURES &APPLIANCES SHOWNDASHED NEW EXTERIOR WALLS RELOCATEDDOOR NEW INTERIORWALL. MAINTAINCHASE FIRE RATING NEW GUARDRAILDECK 1 RELOCATEDLIGHT FIXTURE KITCHEN STAIRENTRY BATH 1BEDROOM 1 CL 3NEW CUSTOM BUILT-INWARDROBE PER OWNER NEW CUSTOM BUILT-IN STORAGE PER OWNER NEW SKI RACK PER OWNER TVPANTRYD/W W/D RECONSTRUCT WALLS ASOPEN GUARDRAILS PEROWNER. COMPLY W/ IRC R312 TV NEW KITCHENCABINETS,COUNTERTOPS,FIXTURES &APPLIANCES PEROWNER. COMPLYW/ IRC R306 ELEC. P OPTION: DEMO DWH & WALLS.INSTALL ELECT. TANKLESSDWH & TWO SINK VANITY DINING ROOM LIVING ROOM 1 4 3 A B CD E 2 REF. NEW CUSTOMCABINETRY FORWASHER/DRYER,PANTRY &REFRIGERATOR 3' - 4" NEW VANITY,TOILET & SHOWERPER OWNER.COMPLY W/ IRCR306 & R307 NEW INTERIOR DOORS PEROWNER (TYP.) TILE CRP TILE CRP WOOD TILECRP WOOD 32" 30" 30" 24" NEW HANDRAIL. COMPLY W/IRC R311.7.7 SCAL E PROJECT NUMBER DRAWN BY CHECKED BY COPYRI GHT 2012 1DRC PRELI M. REVI EW 05.12.11 2BI D SET06.15.11 3T. O. V. PERMI T SET05.24.12 4T. O. V. I NT. PERMIT SET08.30.12 As i ndi cat ed 1476 WESTHAVEN DR. UNI T #3 ( COLDSTREAM) VAI L, CO 81657 PARCEL #210312108003 ACCOUNT #R013068 A2. 01 SE COND FLOOR PL A N 0611 KOELBEL RESIDENCE INTERIOR ALTERATION ML ML T. O. V. I NT ERI OR PER MI T SUBMI TT AL 08. 30. 12 1/4" = 1'-0" 1 SECOND FLOOR PLANGENERAL NOTES:1. GRAY HATCH INDICATES NEW WALLS.NOTE: ONLY THE INTERIORSCOPE OF WORK (SHOWNABOVE DASHED LINE) ISINCLUDED IN THIS PERMIT SETNOTE: THE EXTERIOR SCOPEOF WORK (SHOWN BELOWDASHED LINE) WAS INCLUDEDIN THE EXTERIOR PERMITSET DATED 05.24.12 (PERMIT# B12-0210) NO.DESCRI PTION DATE STAIR MASTER BATH MASTER BEDROOM DECK 2 OPEN TO BELOWOFFICE MASTER CLOSET 1 4 3 A B CD E 2 SCAL E PROJECT NUMBER DRAWN BY CHECKED BY COPYRI GHT 2012 As i ndi c at ed 1476 WESTHAVEN DR. UNI T #3 ( COLDSTREAM) VAI L, CO 81657 PARCEL #210312108003 ACCOUNT #R013068 A2. 02 T HRI D FL OOR DEMO PL AN 0611 Aut hor Checker KOELBEL RESIDENCE INTERIOR ALTERATION T. O. V. I NT ERI OR PER MI T SUBMI TT AL 08. 30. 12 1/4" = 1'-0" 1 THIRD FLOOR DEMO PLAN NOTE: ONLY THE INTERIORSCOPE OF WORK (SHOWNABOVE DASHED LINE) ISINCLUDED IN THIS PERMIT SETNOTE: THE EXTERIOR SCOPEOF WORK (SHOWN BELOWDASHED LINE) WAS INCLUDEDIN THE EXTERIOR PERMITSET DATED 05.24.12 (PERMIT# B12-0210) GENERAL NOTES:1. GRAY HATCH INDICATES EXISTING WALLS. 2. DASHED LINES INDICATE DEMOLISHED/REMOVED.NO. DESCRIPTI ONDATE DEMO WALLS, DOORS,STAIRS, HANDRAILS,CABINETS, FIXTURES &APPLIANCES SHOWNDASHED STAIR DECK 2 OPEN TO BELOWOFFICE NEW CUSTOM BUILT-INWARDROBE PER OWNER TV BENCH CASED OPENINGTO ALIGN W/SKYLIGHT ABOVE.OPTION: INSTALLOPERABLE ORFIXED WINDOW MASTER BATHMASTER BEDROOMEXTEND EXISTINGRAILING TO FULLHT. WALLS INTHESE LOCATIONS 1 4 3 A B CDE 2 6' - 0" 0' - 3 1/2" 6' - 2" 0' - 3 1/2" 6' - 0" NEW VANITY, TOILET &SHOWER PER OWNER.COMPLY W/ IRC R306 & R307 6' +/- NEW INTERIOR DOORS PEROWNER (TYP.) LINE OF DROPPEDCEILING ABOVE32" 30"30" 30" NEW HANDRAIL. COMPLY W/IRC R311.7.7 CRP TILETILE CRP SCAL E PROJECT NUMBER DRAWN BY CHECKED BY COPYRI GHT 2012 As i ndi cat ed 1476 WESTHAVEN DR. UNI T #3 ( COLDSTREAM) VAI L, CO 81657 PARCEL #210312108003 ACCOUNT #R013068 A2. 03 T HI RD FL OOR PL AN 0611 ML ML KOELBEL RESIDENCE INTERIOR ALTERATION T. O. V. I NT ERI OR PER MI T SUBMI TT AL 08. 30. 12 1/4" = 1'-0" 1 THIRD FLOOR PLAN NOTE: ONLY THE INTERIORSCOPE OF WORK (SHOWNABOVE DASHED LINE) ISINCLUDED IN THIS PERMIT SETNOTE: THE EXTERIOR SCOPEOF WORK (SHOWN BELOWDASHED LINE) WAS INCLUDEDIN THE EXTERIOR PERMITSET DATED 05.24.12 (PERMIT# B12-0210) GENERAL NOTES:1. GRAY HATCH INDICATES NEW WALLS. NO.DESCRI PTION DATE GFI 3 T TV TV 3 3 TT GFI TT 34 4 1 4 3 A B CD E 2 DECK 1KITCHEN STAIRENTRY BATH 1BEDROOM 1 CL 3 BUILT-IN STORAGE TV PANTRYD/W W/D ELEC. P DINING ROOM LIVING ROOM REF. RELOCATE RELOCATERELOCATE RELOCATE RELOCATE RELOCATE RELOCATE RELOCATE RELOCATE C C D S NEW ELECTRICRADIENT FLOORHEATING MATUNDER TILE C FL RELOCATE RELOCATE FAN ONLYRELOCATE C CC RELOCATERELOCATE C C RELOCATE UNDER CAB. LIGHTS 220 RELOCATE RELOCATE TO J-BOX ABOVE SCAL E PROJECT NUMBER DRAWN BY CHECKED BY COPYRI GHT 2012 1DRC PRELI M. REVI EW05. 12. 11 2BI D SET06. 15. 11 3T. O. V. PERMI T SET05. 24. 12 4T. O. V. I NT. PERMI T SET08. 30. 12 As i ndi c at ed 1476 WESTHAVEN DR. UNI T #3 ( COLDSTREAM) VAI L, CO 81657 PARCEL #210312108003 ACCOUNT #R013068 A2. 04 SEC OND FL OOR LI GHTI N G & EL ECT RI CAL PL AN 0611 KOELBEL RESIDENCE INTERIOR ALTERATION Aut hor Checker T. O. V. I NT ERI OR PER MI T SUBMI TT AL 08. 30. 12 1/4" = 1'-0" 1 SECOND FLOOR LIGHTING &ELECTRICAL PLAN GENERAL NOTES:1. ONLY NEW & RELOCATED ELECTRICALFIXTURES (LIGHTING, SWITCHING, OUTLETS,CABLE, CAT5, TELEPHONE, THERMOSTAT & HEATREGISTERS) ARE SHOWN. 2. RELOCATED EXISTING ELECTRICAL FIXTURESARE NOTED. 3. EXISTING ELECTRICAL FIXTURES ON DEMOWALLS THAT ARE NOT RELOCATED ARE TO BEABANDONED. 4. REMOVE ALL HUMIDIFICATION UNITS & THEIRCONTROLS. 5. ALL EXISTING HEAT REGISTERS ARE TO BEREPLACED W/ NEW HEAT REGISTERS OF THESAME HEATING CAPACITY. NO. DESCRIPTI ONDATE T 3 TV 3 GFI 3 GFI TV TT T 44 4 J 1 4 3 A B CD E 2 STAIR DECK 2 OPEN TO BELOWOFFICE BENCH MASTER BATHMASTER BEDROOM S RELOCATE RELOCATE RELOCATE RELOCATERELOCATE RELOCATE C RELOCATE C NEW ELECTRICRADIENT FLOORHEATING MATUNDER TILE RELOCATE RELOCATE FAN ONLY C FL TO SWITCH BELOW SCAL E PROJECT NUMBER DRAWN BY CHECKED BY COPYRI GHT 2012 1DRC PRELI M. REVI EW 05.12.11 2BI D SET06.15.11 3T. O. V. PERMI T SET05.24.12 4T. O. V. I NT. PERMIT SET08.30.12 As i ndi cat ed 1476 WESTHAVEN DR. UNI T #3 ( COLDSTREAM) VAI L, CO 81657 PARCEL #210312108003 ACCOUNT #R013068 A2. 05 THI RD FL OOR LI GHTI NG & EL ECTRI CAL PL AN 0611 KOELBEL RESIDENCE INTERIOR ALTERATION Aut hor Checker T. O. V. I NT ERI OR PER MI T SUBMI TT AL 08. 30. 12 1/4" = 1'-0" 1 THIRD FLOOR LIGHTING & ELECTRICALPLAN NO.DESCRI PTION DATE GENERAL NOTES:1. ONLY NEW & RELOCATED ELECTRICALFIXTURES (LIGHTING, SWITCHING, OUTLETS,CABLE, CAT5, TELEPHONE, THERMOSTAT & HEATREGISTERS) ARE SHOWN. 2. RELOCATED EXISTING ELECTRICAL FIXTURESARE NOTED. 3. EXISTING ELECTRICAL FIXTURES ON DEMOWALLS THAT ARE NOT RELOCATED ARE TO BEABANDONED. 4. REMOVE ALL HUMIDIFICATION UNITS & THEIRCONTROLS. 5. ALL EXISTING HEAT REGISTERS ARE TO BEREPLACED W/ NEW HEAT REGISTERS OF THESAME HEATING CAPACITY.